Sample records for versatile high-permittivity phantom

  1. High permittivity gate dielectric materials

    CERN Document Server

    2013-01-01

    "The book comprehensively covers all the current and the emerging areas of the physics and the technology of high permittivity gate dielectric materials, including, topics such as MOSFET basics and characteristics, hafnium-based gate dielectric materials, Hf-based gate dielectric processing, metal gate electrodes, flat-band and threshold voltage tuning, channel mobility, high-k gate stack degradation and reliability, lanthanide-based high-k gate stack materials, ternary hafnia and lanthania based high-k gate stack films, crystalline high-k oxides, high mobility substrates, and parameter extraction. Each chapter begins with the basics necessary for understanding the topic, followed by a comprehensive review of the literature, and ultimately graduating to the current status of the technology and our scientific understanding and the future prospects."

  2. Advanced Radiation DOSimetry phantom (ARDOS): a versatile breathing phantom for 4D radiation therapy and medical imaging

    Science.gov (United States)

    Kostiukhina, Natalia; Georg, Dietmar; Rollet, Sofia; Kuess, Peter; Sipaj, Andrej; Andrzejewski, Piotr; Furtado, Hugo; Rausch, Ivo; Lechner, Wolfgang; Steiner, Elisabeth; Kertész, Hunor; Knäusl, Barbara

    2017-10-01

    A novel breathing phantom was designed for being used in conventional and ion-beam radiotherapy as well as for medical imaging. Accurate dose delivery and patient safety are aimed to be verified for four-dimensional (4D) treatment techniques compensating for breathing-induced tumor motion. The phantom includes anthropomorphic components representing an average human thorax. It consists of real tissue equivalent materials to fulfill the requirements for dosimetric experiments and imaging purposes. The different parts of the torso (lungs, chest wall, and ribs) and the tumor can move independently. Simple regular movements, as well as more advanced patient-specific breathing cycles are feasible while a reproducible setup can be guaranteed. The phantom provides the flexibility to use different types of dosimetric devices and was designed in a way that it is robust, transportable and easy to handle. Tolerance levels and the reliability of the phantom setup were determined in combination with tests on motion accuracy and reproducibility by using infrared optical tracking technology. Different imaging was performed including positron emission tomography imaging, 4D computed tomography as well as real-time in-room imaging. The initial dosimetric benchmarking studies were performed in a photon beam where dose parameters are predictable and the dosimetric procedures well established.

  3. Resonance continuum coupling in high-permittivity dielectric metamaterials

    Science.gov (United States)

    Lepetit, Thomas; Akmansoy, Eric; Ganne, Jean-Pierre; Lourtioz, Jean-Michel

    2010-11-01

    A detailed investigation of resonance-continuum coupling is carried out both experimentally and theoretically in metamaterials based on high-permittivity dielectric subwavelength resonators. An original experimental scheme is designed at microwave frequencies, which mimics a periodic array of resonators. Fano resonances are discussed in the framework of temporal coupled mode theory for the cases where one or two resonator modes couples to the continuum. Fano lineshapes are unambiguously demonstrated experimentally for the single-mode case in agreement with theoretical modeling. Numerical evidence of resonance trapping is shown in the two-mode case when modes with the same symmetry coincide in frequency.

  4. Modular transmit/receive arrays using very-high permittivity dielectric resonator antennas.

    Science.gov (United States)

    O'Reilly, Thomas P A; Ruytenberg, Thomas; Webb, Andrew G

    2018-03-01

    Dielectric resonator antenna (DRAs) are compact structures that exhibit low coupling between adjacent elements and therefore can be used as MRI transmit arrays. In this study, we use very high permittivity materials to construct modular flexible transceive arrays of a variable numbers of elements for operation at 7T. DRAs were constructed using rectangular blocks of ceramic (lead zirconate titanate, εr  = 1070) with the transverse electric (TE)01 mode tuned to 298 MHz. Finite-difference time-domain simulations were used to determine the B1 and specific absorption rate distributions. B1+ maps were acquired in a phantom to validate the simulations. Performance was compared to an equally sized surface coil. In vivo images were acquired of the wrist (four elements), ankle (seven elements), and calf muscle (16 elements). Coupling between DRAs spaced 5 mm apart on a phantom was -18.2 dB compared to -9.1 dB for equivalently spaced surface coils. DRAs showed a higher B1+ intensity close to the antenna but a lower penetration depth compared to the surface coil. DRAs show very low coupling compared to equally sized surface coils and can be used in transceive arrays without requiring decoupling networks. The penetration depth of the current DRA geometry means they are ideally suited to imaging of extremities. Magn Reson Med 79:1781-1788, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  5. Novel encapsulation technique for incorporation of high permittivity fillers into silicone elastomers

    DEFF Research Database (Denmark)

    Mazurek, Piotr Stanislaw; Hvilsted, Søren; Skov, Anne Ladegaard

    2014-01-01

    The research on soft elastomers with high dielectric permittivity for the use as dielectric electroactive polymers (DEAP) has grown substantially within the last decade. The approaches to enhance the dielectric permittivity can be categorized into three main classes: 1) Mixing or blending in high...... permittivity fillers, 2) Grafting of high permittivity molecules onto the polymer backbone in the elastomer, and 3) Encapsulation of high permittivity fillers. The approach investigated here is a new type of encapsulation which does not interfere with the mechanical properties to the same content...... as for the traditionally applied thermoplastic encapsulation. The properties of the elastomers are investigated as function of the filler content and type. The dielectric permittivity, dielectric loss, conductivity, storage modulus as well as viscous loss are compared to elastomers with the same amounts of high...

  6. EBG structures on high permittivity substrate to reduce noise in power distribution networks

    NARCIS (Netherlands)

    Tereshchenko, O.V.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2012-01-01

    The noise reduction effect in a Power Distribution Network (PDN) by implementing Electromagnetic Band Gap structures (EBG) on standard and high permittivity substrates has been investigated. Boards with different EBG structures have been modelled and designed. Using the EBG structures the Power

  7. A new approach for electrical properties estimation using a global integral equation and improvements using high permittivity materials.

    Science.gov (United States)

    Schmidt, Rita; Webb, Andrew

    2016-01-01

    Electrical Properties Tomography (EPT) using MRI is a technique that has been developed to provide a new contrast mechanism for in vivo imaging. Currently the most common method relies on the solution of the homogeneous Helmholtz equation, which has limitations in accurate estimation at tissue interfaces. A new method proposed in this work combines a Maxwell's integral equation representation of the problem, and the use of high permittivity materials (HPM) to control the RF field, in order to reconstruct the electrical properties image. The magnetic field is represented by an integral equation considering each point as a contrast source. This equation can be solved in an inverse method. In this study we use a reference simulation or scout scan of a uniform phantom to provide an initial estimate for the inverse solution, which allows the estimation of the complex permittivity within a single iteration. Incorporating two setups with and without the HPM improves the reconstructed result, especially with respect to the very low electric field in the center of the sample. Electromagnetic simulations of the brain were performed at 3T to generate the B1(+) field maps and reconstruct the electric properties images. The standard deviations of the relative permittivity and conductivity were within 14% and 18%, respectively for a volume consisting of white matter, gray matter and cerebellum. Copyright © 2015 Elsevier Inc. All rights reserved.

  8. High-permittivity thin dielectric padding improves fresh blood imaging of femoral arteries at 3 T.

    Science.gov (United States)

    Lindley, Marc D; Kim, Daniel; Morrell, Glen; Heilbrun, Marta E; Storey, Pippa; Hanrahan, Christopher J; Lee, Vivian S

    2015-02-01

    Fresh blood imaging (FBI) is a useful noncontrast magnetic resonance angiographic (MRA) method for the assessment of peripheral arterial disease, particularly for imaging patients with poor renal function. Compared with 1.5 T, 3 T enables higher signal-to-noise ratio and/or spatiotemporal resolution in FBI. Indeed, previous studies have reported successful FBI of the calf station at 3 T. However, FBI of the thigh station at 3 T has been reported to suffer from signal void in the common femoral artery of 1 thigh only because of the radial symmetry in transmit radiofrequency field (B1+) variation. We sought to increase the signal of femoral artery in FBI at 3 T using high-permittivity dielectric padding. We performed FBI and B1+ mapping of the thigh station at 3 T in 13 human subjects to compare the following 3 dielectric padding settings: no padding, commercially available thick (approximately 5 cm) dielectric padding, and high-permittivity thin (approximately 2 cm) dielectric padding. We characterized the radial symmetry in B1+ variation as well as its impact on the FBI signal at baseline and how dielectric padding improves B1+ and FBI. We evaluated the quality of 3 FBI MRA acquisitions using quantitative (ie, contrast-to-noise ratio of femoral arteries) and qualitative (ie, conspicuity of femoral arteries) analyses. With the subjects positioned on the magnetic resonance table in feet-first, supine orientation, the radial symmetry in B1+ variation attenuates the signal in the right common femoral artery. The signal void can be improved partially with commercial padding and improved further with high-permittivity padding. Averaging the results over the 13 subjects, the mean B1+, contrast-to-noise ratio, and conspicuity scores for the right common femoral artery were significantly higher with high-permittivity padding than with commercial padding and baseline (P permittivity dielectric padding can be used to increase the signal of femoral artery in FBI at 3 T.

  9. Electromechanical stability of electro-active silicone filled with high permittivity particles undergoing large deformation

    Science.gov (United States)

    Liu, Liwu; Liu, Yanju; Zhang, Zhen; Li, Bo; Leng, Jinsong

    2010-11-01

    In this paper, an expression for the permittivity of electro-active silicone undergoing large deformation with high permittivity particles filled uniformly has been proposed. Two expressions are proposed for the permittivity, one based on experimental tests and the other based on the theory of composite material. By applying the thermodynamic model incorporating linear dielectric permittivity and nonlinear hyperelastic performance, the mechanical performance and electromechanical stability of the coupling system constituted by silicone filled with PMN-PT have been studied. The results show that the critical electric field decreases, namely the stability performance of the system declines when the content of PMN-PT c(v) increases and the electrostrictive coefficients increase. The results are beneficial for us to understand deeply the influence of the filled particle on the stability performance of silicone and to guide the design and manufacture of actuators and sensors based on dielectric elastomers.

  10. Reconfigurable all-dielectric metamaterial frequency selective surface based on high-permittivity ceramics

    Science.gov (United States)

    Li, Liyang; Wang, Jun; Wang, Jiafu; Ma, Hua; Du, Hongliang; Zhang, Jieqiu; Qu, Shaobo; Xu, Zhuo

    2016-01-01

    Based on effective medium theory and dielectric resonator theory, we propose the design of reconfigurable all-dielectric metamaterial frequency selective surfaces (FSSs) using high-permittivity ceramics. The FSS is composed of ceramic resonators with different band stop responses under front and side incidences. By mechanically tuning the orientation of the ceramic resonators, reconfigurable electromagnetic (EM) responses between two adjacent stopbands can be achieved. The two broad stopbands originate from the first two resonant modes of the ceramic resonators. As an example, a reconfigurable FSS composed of cross-shaped ceramic resonators is demonstrated. Both numerical and experimental results show that the FSS can switch between two consecutive stopbands in 3.55–4.60 GHz and 4.54–4.94 GHz. The design method can be readily extended to the design of FSSs in other frequencies for high-power applications. PMID:27052098

  11. Ultra-low percolation threshold in ferrite-metal cofired ceramics brings both high permeability and high permittivity.

    Science.gov (United States)

    Wang, Liang; Bai, Yang; Lu, Xuefei; Cao, Jiang-Li; Qiao, Li-Jie

    2015-01-05

    High permeability and high permittivity are hard to be achieved simultaneously, either in single-phased materials or in composite materials, such as ferrite-ferroelectric ceramic composites and ferrite-metal percolative composites. In this work, ultra-low percolation threshold is achieved in NiZnCu ferrite-Ag cofired ceramics, which endows the composite with both high permeability and high permittivity by minimizing the negative effect of nonmagnetic conductive fillers on magnetic properties. The percolation threshold is controlled by the temperature matching between ferrite densification and Ag melting. A thin and long percolative net forms between large ferrite grains under a proper cofiring process, which brings a low percolation threshold of 1.21vol%, more than one order of magnitude lower than the theoretical value of 16vol%. Near the ultra-low threshold, the composite exhibits a high permeability of 585 and a high permittivity of 78.

  12. Improved Cardiac Proton Magnetic Resonance Spectroscopy at 3 T Using High Permittivity Pads.

    Science.gov (United States)

    de Heer, Paul; Bizino, Maurice B; Versluis, Maarten J; Webb, Andrew G; Lamb, Hildo J

    2016-02-01

    The aim of this study was to determine whether high permittivity (HP) pads can be used to increase the signal-to-noise ratio (SNR) of cardiac proton magnetic resonance spectroscopy at 3 T, allowing faster data acquisition. The institutional review board approved the study protocol, and written informed consent was obtained from all participants. In 22 healthy volunteers, water-suppressed localized spectra were acquired in the interventricular septum without and with HP pads. The SNR and myocardial triglyceride content (MTGC) were measured without and with the HP pads, and the results were compared with a paired sample Student t test. Application of HP pads increased mean (SD) SNR from 27.9 (15.6) to 42.3 (24.4) (P permittivity pads improve cardiac proton magnetic resonance spectroscopy at 3 T by increasing the SNR on average by 60%, which can be used to reduce data acquisition time significantly, allowing fast assessment of MTGC without compromising spectral quality. The SNR increase arises primarily from the increase in receive sensitivity of the phased array, which is more closely coupled to the body via the HP pads. In addition, the transmit efficiency is also increased, allowing shorter or lower power radiofrequency pulses.

  13. Yttrium scandate thin film as alternative high-permittivity dielectric for germanium gate stack formation

    Science.gov (United States)

    Lu, Cimang; Lee, Choong Hyun; Nishimura, Tomonori; Toriumi, Akira

    2015-08-01

    We investigated yttrium scandate (YScO3) as an alternative high-permittivity (k) dielectric thin film for Ge gate stack formation. Significant enhancement of k-value is reported in YScO3 comparing to both of its binary compounds, Y2O3 and Sc2O3, without any cost of interface properties. It suggests a feasible approach to a design of promising high-k dielectrics for Ge gate stack, namely, the formation of high-k ternary oxide out of two medium-k binary oxides. Aggressive scaling of equivalent oxide thickness (EOT) with promising interface properties is presented by using YScO3 as high-k dielectric and yttrium-doped GeO2 (Y-GeO2) as interfacial layer, for a demonstration of high-k gate stack on Ge. In addition, we demonstrate Ge n-MOSFET performance showing the peak electron mobility over 1000 cm2/V s in sub-nm EOT region by YScO3/Y-GeO2/Ge gate stack.

  14. Flexible Ultrahigh-Temperature Polymer-Based Dielectrics with High Permittivity for Film Capacitor Applications

    Directory of Open Access Journals (Sweden)

    Zejun Pu

    2017-11-01

    Full Text Available In this report, flexible cross-linked polyarylene ether nitrile/functionalized barium titanate(CPEN/F-BaTiO3 dielectrics films with high permittivitywere prepared and characterized. The effects of both the F-BaTiO3 and matrix curing on the mechanical, thermal and dielectric properties of the CPEN/F-BaTiO3 dielectric films were investigated in detail. Compared to pristine BaTiO3, the surface modified BaTiO3 particles effectively improved their dispersibility and interfacial adhesion in the polymer matrix. Moreover, the introduction of F-BaTiO3 particles enhanced dielectric properties of the composites, with a relatively high permittivity of 15.2 and a quite low loss tangent of 0.022 (1 kHz when particle contents of 40 wt % were utilized. In addition, the cyano (–CN groups of functional layer also can serve as potential sites for cross-linking with polyarylene ether nitrile terminated phthalonitrile (PEN-Ph matrix and make it transform from thermoplastic to thermosetting. Comparing with the pure PEN-ph film, the latter results indicated that the formation of cross-linked network in the polymer-based system resulted in increased tensile strength by ~67%, improved glass transition temperature (Tg by ~190 °C. More importantly, the CPEN/F-BaTiO3 composite films filled with 30 wt % F-BaTiO3 particles showed greater energy density by nearly 190% when compared to pure CPEN film. These findings enable broader applications of PEN-based composites in high-performance electronics and energy storage devices materials used at high temperature.

  15. Performance of High-Permittivity Ceramic-Polymer Composite as a Substrate for UHF RFID Tag Antennas

    Directory of Open Access Journals (Sweden)

    A. A. Babar

    2012-01-01

    Full Text Available A high-permittivity ceramic-polymer composite substrate is fabricated and proposed for its potential use in UHF RFID tags. The substrate is developed using high-permittivity Barium Titanate (BaTiO3 ceramic powder mixed with polydimethylsiloxane (PDMS polymer. The resulting composite achieves a soft, hydrophobic, heat resistant, low loss, and flexible material with high dielectric constant. The percentage of the ceramic powder in the composite helps in achieving variable permittivity values. When this material is used as a substrate for a tag antenna, it will help the tag to be reduced in size, to conform to uneven or rough surface, and to be less vulnerable to breakage or other environmental damages. A small passive UHF RFID tag antenna is designed, fabricated, and attached to this type of composite substrate, to demonstrate the performance of this composite material.

  16. Improved image quality and reduced power deposition in the spine at 3 T using extremely high permittivity materials.

    Science.gov (United States)

    Koolstra, Kirsten; Börnert, Peter; Brink, Wyger; Webb, Andrew

    2018-02-01

    To explore the effect of using extremely high permittivity (εr ∼1,000) materials on image quality and power requirements of spine imaging at 3 T. A linear array of high permittivity dielectric blocks made of lead zirconate titanate (PZT) was designed and characterized by electromagnetic simulations and experiments. Their effect on the transmit efficiency, receive sensitivity, power deposition, and diagnostic image quality was analyzed in vivo in 10 healthy volunteers. Simulation results showed that for quadrature mode excitation, the PZT blocks improve the transmit efficiency by 75% while reducing the maximum 10g average specific absorption rate (SAR10 ) by 20%. In vivo experiments in 10 healthy volunteers showed statistically significant improvements for the transmit efficiency, and image quality. Compared to active radiofrequency shimming, image quality was similar, but the required system input power was significantly lower for quadrature excitation using the PZT blocks. For single-channel transmit systems, using high permittivity PZT blocks offer a way to improve transmit efficiency and image quality in the spine. Results show that the effect, and therefore optimal design, is body mass index and sex specific. Magn Reson Med 79:1192-1199, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine.

  17. Practical improvements in the design of high permittivity pads for dielectric shimming in neuroimaging at 7T.

    Science.gov (United States)

    O'Reilly, T P A; Webb, A G; Brink, W M

    2016-09-01

    Improvements are proposed for practical design and use of high permittivity materials in high field neuroimaging in three different areas: (i) a simple formula to predict the permittivity of tri-component aqueous-based perovskite suspensions with relative permittivities between 110 and 300, (ii) characterization of addition of a hydroxyethyl-cellulose gelling agent to improve the long-term stability and material properties of "dielectric pads", and (iii) investigation of the integration of, for example, headphones into the dielectric pads to increase patient comfort within tightly-fitting receive coil arrays. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Passive radiofrequency shimming in the thighs at 3 Tesla using high permittivity materials and body coil receive uniformity correction.

    Science.gov (United States)

    Brink, Wyger M; Versluis, Maarten J; Peeters, Johannes M; Börnert, Peter; Webb, Andrew G

    2016-12-01

    To explore the effects of high permittivity dielectric pads on the transmit and receive characteristics of a 3 Tesla body coil centered at the thighs, and their implications on image uniformity in receive array applications. Transmit and receive profiles of the body coil with and without dielectric pads were simulated and measured in healthy volunteers. Parallel imaging was performed using sensitivity encoding (SENSE) with and without pads. An intensity correction filter was constructed from the measured receive profile of the body coil. Measured and simulated data show that the dielectric pads improve the transmit homogeneity of the body coil in the thighs, but decrease its receive homogeneity, which propagates into reconstruction algorithms in which the body coil is used as a reference. However, by correcting for the body coil reception profile this effect can be mitigated. Combining high permittivity dielectric pads with an appropriate body coil receive sensitivity filter improves the image uniformity substantially compared with the situation without pads. Magn Reson Med 76:1951-1956, 2016. © 2015 International Society for Magnetic Resonance in Medicine. © 2015 International Society for Magnetic Resonance in Medicine.

  19. Nano-laminate vs. direct deposition of high permittivity gadolinium scandate on silicon by high pressure sputtering

    Energy Technology Data Exchange (ETDEWEB)

    Feijoo, P.C., E-mail: pedronska@fis.ucm.es [Dpto. Física Aplicada III (Electricidad y Electrónica), Universidad Complutense de Madrid, Fac. de CC. Físicas. Av/Complutense S/N, E-28040 Madrid (Spain); Pampillón, M.A.; San Andrés, E. [Dpto. Física Aplicada III (Electricidad y Electrónica), Universidad Complutense de Madrid, Fac. de CC. Físicas. Av/Complutense S/N, E-28040 Madrid (Spain); Fierro, J.L.G. [Instituto de Catálisis y Petroleoquímica, Consejo Superior de Investigaciones Científicas, C/Marie Curie 2, E-28049 Cantoblanco (Spain)

    2015-10-30

    In this work we use the high pressure sputtering technique to deposit the high permittivity dielectric gadolinium scandate on silicon substrates. This nonconventional deposition technique prevents substrate damage and allows for growth of ternary compounds with controlled composition. Two different approaches were assessed: the first one consists of depositing the material directly from a stoichiometric GdScO{sub 3} target; in the second one, we anneal a nano-laminate of < 0.5 nm thick Gd{sub 2}O{sub 3} and Sc{sub 2}O{sub 3} films in order to control the composition of the scandate. Metal–insulator–semiconductor capacitors were fabricated with platinum gates for electrical characterization. Accordingly, we grew a Gd-rich Gd{sub 2−x}Sc{sub x}O{sub 3} film that, in spite of higher leakage currents, presents a better effective relative permittivity of 21 and lower density of defects. - Highlights: • GdScO is deposited on Si as a high permittivity dielectric by two procedures. • Films sputtered from GdScO{sub 3} target are Sc-rich and present thick interface SiO{sub x}. • Gd-rich GdScO is obtained from a nano-laminate sputtered from Sc{sub 2}O{sub 3} and Gd{sub 2}O{sub 3}. • Gd{sub 1.8}Sc{sub 0.2}O{sub 3} shows good effective permittivity and electrical properties.

  20. The effect of high-permittivity pads on specific absorption rate in radiofrequency-shimmed dual-transmit cardiovascular magnetic resonance at 3T.

    Science.gov (United States)

    Brink, Wyger M; van den Brink, Johan S; Webb, Andrew G

    2015-09-19

    Dual-channel transmit technology improves the image quality in cardiovascular magnetic resonance (CMR) at 3 T by reducing the degree of radiofrequency (RF) shading over the heart by using RF shimming. Further improvements in image quality have been shown on a dual-transmit system using high permittivity pads. The aim of this study is to investigate the transmit field (B 1 (+)) homogeneity and the specific absorption rate (SAR) using high permittivity pads as a function of the complete range of possible RF-shim settings in order to gauge the efficacy and safety of this approach. Electromagnetic (EM) simulations were performed in five different body models using a dual-transmit RF coil, with and without high permittivity pads. The RF shimming behaviour in terms of B 1 (+) homogeneity and local SAR were determined as a function of different RF-shim settings. Comparative experimental data were obtained in healthy volunteers (n = 33) on either a standard-bore (60 cm diameter) or wide-bore (70 cm diameter) 3 T CMR system. EM simulations and experimental data showed higher (B 1 (+)) homogeneity and lower SAR for optimized RF-shim settings when using the high permittivity pads. The power distribution between the two channels was also much closer to being equal using the pads. EM simulations showed that for all five body models studied, optimized RF-shim settings corresponded to reduced local SAR using high permittivity pads. However, there are also specific, non-optimal RF-shim settings for which the actual SAR using the pads would be higher (up to ~20 %) than that calculated by the CMR system. The combination of active (dual transmit) and passive (high permittivity pads) RF shimming shows great promise for increasing image quality for cardiac imaging at 3 T. Optimized RF-shim settings result in increased B 1 (+) homogeneity and reduced SAR with the high permittivity pads: however, there are non-optimal cases in which SAR might be underestimated, and these merit

  1. Simulations of high permittivity materials for 7 T neuroimaging and evaluation of a new barium titanate-based dielectric.

    Science.gov (United States)

    Teeuwisse, W M; Brink, W M; Haines, K N; Webb, A G

    2012-04-01

    High permittivity "dielectric pads" have been shown to increase image quality at high magnetic fields in regions of low radiofrequency transmit efficiency. This article presents a series of electromagnetic simulations to determine the effects of pad size and geometry, relative permittivity value, as well as thickness on the transmit radiofrequency fields for neuroimaging at 7 T. For a 5-mm thick pad, there is virtually no effect on the transmit field for relative permittivity values lower than ∼90. Significant improvements are found for values between 90 and ∼180. If the relative permittivity is increased above ∼180 then areas of very low transmit efficiency are produced. For a 1-cm thick pad, the corresponding numbers are ∼60 and ∼120, respectively. Based upon the findings, a new material (barium titanate, relative permittivity ∼150) is used to produce thin (∼5 mm) dielectric pads which can easily be placed within a standard receive head array. Experimental measurements of transmit sensitivities, as well as acquisition of T(2) - and T 2*-weighted images show the promise of this approach. Copyright © 2012 Wiley Periodicals, Inc.

  2. Approaching ultimate intrinsic specific absorption rate in radiofrequency shimming using high-permittivity materials at 7 Tesla.

    Science.gov (United States)

    Haemer, Gillian G; Vaidya, Manushka; Collins, Christopher M; Sodickson, Daniel K; Wiggins, Graham C; Lattanzi, Riccardo

    2017-11-28

    The aim of this study was to evaluate the effect of integrated high-permittivity materials (HPMs) on excitation homogeneity and global specific absorption rate (SAR) for transmit arrays at 7T. A rapid electrodynamic simulation framework was used to calculate L-curves associated with excitation of a uniform 2D profile in a dielectric sphere. We used ultimate intrinsic SAR as an absolute performance reference to compare different transmit arrays in the presence and absence of a layer of HPM. We investigated the optimal permittivity for the HPM as a function of its thickness, the sample size, and the number of array elements. Adding a layer of HPM can improve the performance of a 24-element array to match that of a 48-element array without HPM, whereas a 48-element array with HPM can perform as well as a 64-element array without HPM. Optimal relative permittivity values changed based on sample and coil geometry, but were always within a range obtainable with readily available materials (εr  = 100-200). Integration of HPMs could be a practical method to improve RF shimming performance, alternative to increasing the number of coils. The proposed simulation framework could be used to explore the design of novel transmit arrays for head imaging at ultra-high field strength. Magn Reson Med, 2017. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  3. Magnetic Resonance Imaging of the Temporomandibular Joint at 7.0 T Using High-Permittivity Dielectric Pads: A Feasibility Study.

    Science.gov (United States)

    Manoliu, Andrei; Spinner, Georg; Wyss, Michael; Ettlin, Dominik A; Nanz, Daniel; Kuhn, Felix P; Gallo, Luigi M; Andreisek, Gustav

    2015-12-01

    The aims of this study were to show feasibility and to quantitatively and qualitatively evaluate the use of high-permittivity dielectric pads for imaging the temporomandibular joint (TMJ) at 7.0 T. This study is an institutional review board-approved study with written informed consent. Ten asymptomatic volunteers (20 TMJs) were magnetic resonance imaged using a 32-channel head coil at 7.0 T (Achieva; Philips Healthcare, the Netherlands) with and without high-permittivity dielectric pads consisting of barium titanate in deuterated suspension. Imaging protocol consisted of an oblique sagittal proton density-weighted turbo-spin echo sequence. For quantitative evaluation, B1 maps and voxelwise signal-to-noise ratio (SNR) maps were calculated. For qualitative evaluation, 2 readers assessed the visibility of anatomical structures of the TMJ and overall image quality on a 5-point Likert scale from 1 (excellent visibility) to 5 (not visible) in consensus. Quantitative and qualitative measurements were compared between images acquired with and without pads. Imaging the TMJ using dielectric pads was feasible in all volunteers. The quantitative analysis showed locally higher B1+ and higher SNR in the area covering the TMJ for the scans performed with dielectric pads compared with those without pads (SNR: mean [SD] pads, 12.38 [3.18]; mean [SD] no pads, 6.60 [0.72]). The qualitative analysis showed significantly better visibility and delineation of clinically relevant anatomical structures of the TMJ, including temporomandibular disc, bilaminar zone, mandibular fossa, mandibular condyle, and pterygoid muscle. In addition, observers judged overall image quality as better for images taken with pads compared with those taken without pads (mean [SD] pads, 1.40 [0.50]; mean [SD] no pads, 4.25 [0.78]). The application of high-permittivity dielectric pads improves the local B1+ field and thus the SNR, optimizing TMJ magnetic resonance imaging at 7.0 T.

  4. Human phantom

    CERN Multimedia

    CERN PhotoLab

    1973-01-01

    This human phantom has been received by CERN on loan from the State Committee of the USSR for the Utilization of Atomic Energy. It is used by the Health Physics Group to study personel radiation doses near the accelerators.

  5. Phantom Pain

    Science.gov (United States)

    ... 16, 2014. Phantom pain Symptoms & causes Diagnosis & treatment Advertisement Mayo Clinic does not endorse companies or products. ... a Job Site Map About This Site Twitter Facebook Google YouTube Pinterest Mayo Clinic is a not- ...

  6. Phantom thermodynamics

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Diaz, Pedro F. [Colina de los Chopos, Centro de Fisica ' Miguel A. Catalan' , Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)]. E-mail: p.gonzalezdiaz@imaff.cfmac.csic.es; Sigueenza, Carmen L. [Colina de los Chopos, Centro de Fisica ' Miguel A. Catalan' , Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)

    2004-10-04

    This paper deals with the thermodynamic properties of a phantom field in a flat Friedmann-Robertson-Walker universe. General expressions for the temperature and entropy of a general dark-energy field with equation of state p={omega}{rho} are derived from which we have deduced that, whereas the temperature of a cosmic phantom fluid ({omega}-1) is definite negative, its entropy is always positive. We interpret that result in terms of the intrinsic quantum nature of the phantom field and apply it to (i) attain a consistent explanation for some recent results concerning the evolution of black holes which,induced by accreting phantom energy, gradually loss their mass to finally vanish exactly at the big rip, and (ii) introduce the concept of cosmological information and its relation with life and the anthropic principle. Some quantum statistical-thermodynamic properties of the quantum field are also considered that include a generalized Wien law and the prediction of some novel phenomena such as the stimulated absorption of phantom energy and the anti-laser effect.

  7. Potential for high-permittivity materials to reduce local SAR at a pacemaker lead tip during MRI of the head with a body transmit coil at 3 T.

    Science.gov (United States)

    Yu, Zidan; Xin, Xuegang; Collins, Christopher M

    2017-07-01

    To illustrate the potential for high permittivity materials to be used in decreasing peak local SAR associated with implants when the imaging region is far from the implant. We performed numerical simulations of a human subject with a pacemaker in a body-sized birdcage coil driven at 128 MHz with and without a thin (5 mm) shell of material of high electric permittivity around the head. For a shell with relative permittivity of 600, the maximum specific energy absorption rate averaged over any 1 g of tissue near the pacemaker was reduced by 73.5% for a given B1 field strength at the center of the brain. Although further study is required, initial simulations indicate that strategic use of high permittivity materials may broaden the conditions under which patients with certain implants can be imaged safely. Magn Reson Med 78:383-386, 2017. © 2016 International Society for Magnetic Resonance in Medicine. © 2016 International Society for Magnetic Resonance in Medicine.

  8. 21. Phantom pain.

    NARCIS (Netherlands)

    Wolff, A.P.; Vanduynhoven, E.; Kleef, M. van; Huygen, F.; Pope, J.E.; Mekhail, N.

    2011-01-01

    Phantom pain is pain caused by elimination or interruption of sensory nerve impulses by destroying or injuring the sensory nerve fibers after amputation or deafferentation. The reported incidence of phantom limb pain after trauma, injury or peripheral vascular diseases is 60% to 80%. Over half the

  9. Realistic computerized human phantoms

    Science.gov (United States)

    Zankl, M.; Veit, R.; Petoussi, N.; Mannweiler, E.; Wittmann, A.; Drexler, G.

    1994-10-01

    To estimate the risk resulting from exposures to ionizing radiation, the organ and tissue doses should be assessed. A convenient method is the calculation of these doses using representations of the human body, called models or phantoms, together with computer codes simulating the transport of radiation in the body. Most commonly used are mathematical phantoms whose external and internal volumes are defined by simple geometric bodies. More recently, phantoms constructed from computed tomographic data of real persons were introduced as an improvement. These phantoms present advantages concerning the location and shape of the organs, in particular the hard bone and bone marrow, whose distribution can be assessed with high resolution. So far, three of these phantoms were constructed at the GSF, a fourth is under process. The construction technique is described, and some calculational results of organ doses due to external photon irradiation are presented.

  10. Versatility of microbial transglutaminase.

    Science.gov (United States)

    Strop, Pavel

    2014-05-21

    Although microbial transglutaminases (mTGs) were initially discovered to offset the cost of producing mammalian transglutaminases for food applications, they have quickly become important tools in research and biotechnology. Today, mTGs are utilized for a large number of applications to conjugate proteins and peptides to small molecules, polymers, surfaces, and DNA, as well as to other proteins. It is important to know how to maximize the advantages of the enzymatic approach and avoid undesired cross-linking. This review focuses on the versatility of transglutaminases in the field of bioconjugation and covers recent developments in utilizing mTG for generating antibody drug conjugates (ADCs) for therapeutic applications.

  11. Applying technical versatility

    Energy Technology Data Exchange (ETDEWEB)

    None

    1970-01-01

    The breadth and depth of the diversified technical programs at Mound Laboratory since its inception are characterized by a record of competence and versatility during the past generation. A spectrum of mission assignments has been completed successfully in such diverse technical areas as process development and manufacturing of explosive components, research on fuels for the Civilian Power Reactor Program, separation of radioactive materials, fabrication of radioisotopic heat sources, stable gaseous isotope separation and purification, and many other areas. Mound Laboratory is one of the key U.S. Atomic Energy Commission sites that has demonstrated its technical competence in both weapons and non-weapons activities. This report has been prepared to complement the AEC’s vigorous program of scientific information dissemination. Three broad areas of technical competence are highlighted here: explosive technology, radionuclide technology, and stable gaseous isotope separation, which encompass a broad variety of techniques and supporting disciplines.

  12. Holographic versatile disc system

    Science.gov (United States)

    Horimai, Hideyoshi; Tan, Xiaodi

    2005-09-01

    A Holographic Versatile Disc (HVD) system, using Collinear Technologies for a high capacity and high data transfer rates storage system, is proposed. With its unique configuration the optical pickup can be designed as small as a DVD's, and can be placed on one side of the disc. With the HVD's special structure, the system can servo the focus/track and locate reading/writing address. A unique selectable capacity recording format of HVD and its standardization activity are also introduced. Experimental and theoretical studies suggest that the tilt, wavelength, defocus and de-track margins are wide enough to miniaturize the HVD system at a low cost. HVD systems using Collinear Technologies will be compatible with existing disc storage systems, like CD and DVD, and will enable us to expand its applications into other optical information storage systems.

  13. Versatile by design

    CERN Multimedia

    Katarina Anthony

    2014-01-01

    CHARM (CERN High energy AcceleRator Mixed field) is a new and unique testing facility that will complete CERN's radiation testing installations. Located in the East Area, CHARM will provide teams with a venue to test their equipment in radiation environments similar to those found in the accelerator chain.   Team at work in the irradiation zone of the CHARM facility. First envisaged in 2007, the CHARM facility fulfils a growing demand for a large-scale tailor-made radiation testing facility. Unlike commercial facilities, CHARM features a wide spectrum of radiation types and energies (called mixed-field radiation environments), the space to test large equipment and even the possibility to adjust the environment using mobile shielding. "CHARM is versatile by design, allowing us to recreate any of the radiation environments found in the accelerator chain," says Markus Brugger, head of the R2E (Radiation to Electronics) project team that developed the CHARM facility. &a...

  14. An Inexpensive and Easy Ultrasound Phantom: A Novel Use for SPAM.

    Science.gov (United States)

    Nolting, Laura; Hunt, Patrick; Cook, Thomas; Douglas, Barton

    2016-04-01

    Ultrasound models, commonly referred to as "phantoms," are simulation tools for ultrasound education. Commercially produced phantoms are available, but there are "homemade" alternatives such as raw poultry and gelatin molds. Precooked, processed meat, better known as SPAM (Hormel Foods Corporation, Austin, MN), can be used as an ultrasound phantom to teach several ultrasound applications. It is a versatile, hygienic, and easily manipulated medium that does not require refrigeration or preparatory work and can be easily discarded at the end of use. © 2016 by the American Institute of Ultrasound in Medicine.

  15. Jamitons: Phantom Traffic Jams

    Science.gov (United States)

    Kowszun, Jorj

    2013-01-01

    Traffic on motorways can slow down for no apparent reason. Sudden changes in speed by one or two drivers can create a chain reaction that causes a traffic jam for the vehicles that are following. This kind of phantom traffic jam is called a "jamiton" and the article discusses some of the ways in which traffic engineers produce…

  16. The Phantom Menace

    DEFF Research Database (Denmark)

    Vium, Christian

    2013-01-01

    as a phantom menace, which asserts itself through a form of omnipresent fear, nurtured by an inherent opaqueness. As this fundamental fear progressively permeates the nomadic landscape, it engenders a recasting of mobile strategies among the nomadic pastoralist groups who inhabit the interstitial desert spaces....

  17. Fabrication and application of heterogeneous printed mouse phantoms for whole animal optical imaging.

    Science.gov (United States)

    Bentz, Brian Z; Chavan, Anmol V; Lin, Dergan; Tsai, Esther H R; Webb, Kevin J

    2016-01-10

    This work demonstrates the usefulness of 3D printing for optical imaging applications. Progress in developing optical imaging for biomedical applications requires customizable and often complex objects for testing and evaluation. There is therefore high demand for what have become known as tissue-simulating "phantoms." We present a new optical phantom fabricated using inexpensive 3D printing methods with multiple materials, allowing for the placement of complex inhomogeneities in complex or anatomically realistic geometries, as opposed to previous phantoms, which were limited to simple shapes formed by molds or machining. We use diffuse optical imaging to reconstruct optical parameters in 3D space within a printed mouse to show the applicability of the phantoms for developing whole animal optical imaging methods. This phantom fabrication approach is versatile, can be applied to optical imaging methods besides diffusive imaging, and can be used in the calibration of live animal imaging data.

  18. Phantom pain after eye amputation

    DEFF Research Database (Denmark)

    Rasmussen, Marie L R; Prause, Jan U; Toft, Peter B

    2011-01-01

    Purpose: To characterize the quality of phantom pain, its intensity and frequency following eye amputation. Possible triggers and relievers of phantom pain are investigated. Methods: The hospital database was searched using surgery codes for patients who received ocular evisceration, enucleation,...... appears to be similar to the phantom pain suffered by limb amputees. Patients should be informed about this potential complication before surgery....

  19. Trypanosomes - versatile microswimmers

    Science.gov (United States)

    Krüger, Timothy; Engstler, Markus

    2016-11-01

    Evolution has generated a plethora of flagellate microswimmers. They populate all natural waters, from the deep sea to the ponds in our neighbourhood. But flagellates also thrive in the bodies of higher organisms, where they mostly remain undetected, but can also become pathogenic. Trypanosomes comprise a large group of mostly parasitic flagellates that cause many diseases, such as human sleeping sickness or the cattle plague nagana. We consider African trypanosomes as extremely versatile microswimmers, as they have to adapt to very diverse microenvironments. They swim efficiently in the blood of their mammalian hosts, but also in various tissue spaces and even in the human brain. Furthermore, in the transmitting tsetse fly, trypanosomes undergo characteristic morphological changes that are accompanied by amazing transitions between solitary and collective types of motion. In this review, we provide a basic introduction to trypanosome biology and then focus on the complex type of rotational movement that trypanosomes display. We relate their swimming performance to morphological parameters and the respective microenvironment, developing a contemporary view on the physics of trypanosome motility. The genetically programmed successions of life style-dependent motion patterns provide challenges and opportunities for interdisciplinary studies of microswimmers.

  20. Tissue-like phantoms

    Science.gov (United States)

    Frangioni, John V.; De Grand, Alec M.

    2007-10-30

    The invention is based, in part, on the discovery that by combining certain components one can generate a tissue-like phantom that mimics any desired tissue, is simple and inexpensive to prepare, and is stable over many weeks or months. In addition, new multi-modal imaging objects (e.g., beads) can be inserted into the phantoms to mimic tissue pathologies, such as cancer, or merely to serve as calibration standards. These objects can be imaged using one, two, or more (e.g., four) different imaging modalities (e.g., x-ray computed tomography (CT), positron emission tomography (PET), single photon emission computed tomography (SPECT), and near-infrared (NIR) fluorescence) simultaneously.

  1. Versatile Wireless Data Net Project

    Data.gov (United States)

    National Aeronautics and Space Administration — The proposed R&D is to develop a wireless data networking capability. A prototype capability will result from the Phase 1 and 2 contracts. The Versatile Wireless...

  2. DVD - digital versatile disks

    Energy Technology Data Exchange (ETDEWEB)

    Gaunt, R.

    1997-05-01

    An international standard has emerged for the first true multimedia format. Digital Versatile Disk (by its official name), you may know it as Digital Video Disks. DVD has applications in movies, music, games, information CD-ROMS, and many other areas where massive amounts of digital information is needed. Did I say massive amounts of data? Would you believe over 17 gigabytes on a single piece of plastic the size of an audio-CD? That`s the promise, at least, by the group of nine electronics manufacturers who have agreed to the format specification, and who hope to make this goal a reality by 1998. In this major agreement, which didn`t come easily, the manufacturers will combine Sony and Phillip`s one side double-layer NMCD format with Toshiba and Matsushita`s double sided Super-Density disk. By Spring of this year, they plan to market the first 4.7 gigabyte units. The question is: Will DVD take off? Some believe that read-only disks recorded with movies will be about as popular as video laser disks. They say that until the eraseable/writable DVD arrives, the consumer will most likely not buy it. Also, DVD has a good market for replacement of CD- Roms. Back in the early 80`s, the international committee deciding the format of the audio compact disk decided its length would be 73 minutes. This, they declared, would allow Beethoven`s 9th Symphony to be contained entirely on a single CD. Similarly, today it was agreed that playback length of a single sided, single layer DVD would be 133 minutes, long enough to hold 94% of all feature-length movies. Further, audio can be in Dolby`s AC-3 stereo or 5.1 tracks of surround sound, better than CD-quality audio (16-bits at 48kHz). In addition, there are three to five language tracks, copy protection and parental ``locks`` for R rated movies. DVD will be backwards compatible with current CD-ROM and audio CD formats. Added versatility comes by way of multiple aspect rations: 4:3 pan-scan, 4:3 letterbox, and 16:9 widescreen. MPEG

  3. Phantom breast syndrome

    Directory of Open Access Journals (Sweden)

    Ramesh

    2009-01-01

    Full Text Available Phantom breast syndrome is a type of condition in which patients have a sensation of residual breast tissue and can include both non-painful sensations as well as phantom breast pain. The incidence varies in different studies, ranging from approximately 30% to as high as 80% of patients after mastectomy. It seriously affects quality of life through the combined impact of physical disability and emotional distress. The breast cancer incidence rate in India as well as Western countries has risen in recent years while survival rates have improved; this has effectively increased the number of women for whom post-treatment quality of life is important. In this context, chronic pain following treatment for breast cancer surgery is a significantly under-recognized and under-treated problem. Various types of chronic neuropathic pain may arise following breast cancer surgery due to surgical trauma. The cause of these syndromes is damage to various nerves during surgery. There are a number of assumed factors causing or perpetuating persistent neuropathic pain after breast cancer surgery. Most well-established risk factors for developing phantom breast pain and other related neuropathic pain syndromes are severe acute postoperative pain and greater postoperative use of analgesics. Based upon current evidence, the goals of prophylactic strategies could first target optimal peri-operative pain control and minimizing damage to nerves during surgery. There is some evidence that chronic pain and sensory abnormalities do decrease over time. The main group of oral medications studied includes anti-depressants, anticonvulsants, opioids, N-methyl-D-asparate receptor antagonists, mexilitine, topical lidocaine, cannabinoids, topical capsaicin and glysine antagonists. Neuromodulation techniques such as motor cortex stimulation, spinal cord stimulation, and intrathecal drug therapies have been used to treat various neuropathic pain syndromes.

  4. The Phantom of Liberty

    DEFF Research Database (Denmark)

    One of the few things we have in common in contemporary society is the future of our children. But it seems that even the “we” of childhood, of learning and free play, has turned into a common ground for instrumentalization and competition. Today, the pedagogical paradox—Kant’s meditation on the ......? These are some of the questions addressed by The Phantom of Liberty, which sets out to reestablish a social and aesthetic dialogue between visual art and psychology, philosophy, pedagogy, and critical journalism....

  5. Multi-Modality Phantom Development

    Energy Technology Data Exchange (ETDEWEB)

    Huber, Jennifer S.; Peng, Qiyu; Moses, William W.

    2009-03-20

    Multi-modality imaging has an increasing role in the diagnosis and treatment of a large number of diseases, particularly if both functional and anatomical information are acquired and accurately co-registered. Hence, there is a resulting need for multi modality phantoms in order to validate image co-registration and calibrate the imaging systems. We present our PET-ultrasound phantom development, including PET and ultrasound images of a simple prostate phantom. We use agar and gelatin mixed with a radioactive solution. We also present our development of custom multi-modality phantoms that are compatible with PET, transrectal ultrasound (TRUS), MRI and CT imaging. We describe both our selection of tissue mimicking materials and phantom construction procedures. These custom PET-TRUS-CT-MRI prostate phantoms use agargelatin radioactive mixtures with additional contrast agents and preservatives. We show multi-modality images of these custom prostate phantoms, as well as discuss phantom construction alternatives. Although we are currently focused on prostate imaging, this phantom development is applicable to many multi-modality imaging applications.

  6. Temperature characterization of versatile transceivers

    CERN Document Server

    Olanterä, L.; Storey, S; Sigaud, C; Soos, C; Troska, J; Vasey, F

    2013-01-01

    The Versatile Transceiver is a part of the Versatile Link project, which is developing optical link architectures and components for future HL-LHC experiments. While having considerable size and weight constraints, Versatile Transceivers must work under severe environmental conditions. One such environmental parameter is the temperature: the operating temperature range is specified to be from -30 to +60°C. In this contribution we present the results of the temperature characterization of the VTRx transmitter and receiver. Several transmitter candidates from three different manufacturers have been characterized: multi-mode Vertical Cavity Surface-Emitting Lasers and a single-mode Edge-Emitter Laser. Also both single- and multi-mode receivers have been tested.

  7. Multimodal phantom of liver tissue.

    Directory of Open Access Journals (Sweden)

    Magdalena K Chmarra

    Full Text Available Medical imaging plays an important role in patients' care and is continuously being used in managing health and disease. To obtain the maximum benefit from this rapidly developing technology, further research is needed. Ideally, this research should be done in a patient-safe and environment-friendly manner; for example, on phantoms. The goal of this work was to develop a protocol and manufacture a multimodal liver phantom that is suitable for ultrasound, computed tomography, and magnetic resonance imaging modalities. The proposed phantom consists of three types of mimicked soft tissues: liver parenchyma, tumors, and portal veins, that are made of six ingredients: candle gel, sephadex®, agarose, glycerol, distilled water, and silicone string. The entire procedure is advantageous, since preparation of the phantom is simple, rather cost-effective, and reasonably quick - it takes around 2 days. Besides, most of the phantom's parts can be reused to manufacture a new phantom. Comparison of ultrasound images of real patient's liver and the developed phantom shows that the phantom's liver tissue and its structures are well simulated.

  8. Supernumerary phantom limb after stroke

    Science.gov (United States)

    Bakheit, A; Roundhill, S

    2005-01-01

    The perception of a phantom limb is commonly reported after amputations. However, only a few cases have been described after a stroke. This article presents a patient who reported a supernumerary phantom limb (pseudopolymelia) after spontaneous intracerebral haemorrhage and discusses the possible underlying mechanisms for this rare phenomenon. PMID:15749787

  9. Modification of the NEMA XR21-2000 cardiac phantom for testing of imaging systems used in endovascular image guided interventions

    Science.gov (United States)

    Ionita, C. N.; Dohatcu, A.; Jain, A.; Keleshis, C.; Hoffmann, K. R.; Bednarek, D. R.; Rudin, S.

    2009-02-01

    X-ray equipment testing using phantoms that mimic the specific human anatomy, morphology, and structure is a very important step in the research, development, and routine quality assurance for such equipment. Although the NEMA XR21 phantom exists for cardiac applications, there is no such standard phantom for neuro-, peripheral and cardiovascular angiographic applications. We have extended the application of the NEMA XR21-2000 phantom to evaluate neurovascular x-ray imaging systems by structuring it to be head-equivalent; two aluminum plates shaped to fit into the NEMA phantom geometry were added to a 15 cm thick section. Also, to enable digital subtraction angiography (DSA) testing, two replaceable central plates with a hollow slot were made so that various angiographic sections could be inserted into the phantom. We tested the new modified phantom using a flat panel C-arm unit dedicated for endovascular image-guided interventions. All NEMA XR21-2000 standard test sections were used in evaluations with the new "headequivalent" phantom. DSA and DA are able to be tested using two standard removable blocks having simulated arteries of various thickness and iodine concentrations (AAPM Report 15). The new phantom modifications have the benefits of enabling use of the standard NEMA phantom for angiography in both neuro- and cardio-vascular applications, with the convenience of needing only one versatile phantom for multiple applications. Additional benefits compared to using multiple phantoms are increased portability and lower cost.

  10. Xanthan-A Versatile Gum

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 9; Issue 10. Xanthan – A Versatile Gum. Anil Lachke. General Article Volume 9 Issue 10 October 2004 pp 25-33. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/009/10/0025-0033. Keywords. Xanthan ...

  11. Phantom limbs and neural plasticity.

    Science.gov (United States)

    Ramachandran, V S; Rogers-Ramachandran, D

    2000-03-01

    The study of phantom limbs has received tremendous impetus from recent studies linking changes in cortical topography with perceptual experience. Systematic psychophysical testing and functional imaging studies on patients with phantom limbs provide 2 unique opportunities. First, they allow us to demonstrate neural plasticity in the adult human brain. Second, by tracking perceptual changes (such as referred sensations) and changes in cortical topography in individual patients, we can begin to explore how the activity of sensory maps gives rise to conscious experience. Finally, phantom limbs also allow us to explore intersensory effects and the manner in which the brain constructs and updates a "body image" throughout life.

  12. Realistic analytical polyhedral MRI phantoms.

    Science.gov (United States)

    Ngo, Tri M; Fung, George S K; Han, Shuo; Chen, Min; Prince, Jerry L; Tsui, Benjamin M W; McVeigh, Elliot R; Herzka, Daniel A

    2016-08-01

    Analytical phantoms have closed form Fourier transform expressions and are used to simulate MRI acquisitions. Existing three-dimensional (3D) analytical phantoms are unable to accurately model shapes of biomedical interest. The goal of this study was to demonstrate that polyhedral analytical phantoms have closed form Fourier transform expressions and can accurately represent 3D biomedical shapes. The Fourier transform of a polyhedron was implemented and its accuracy in representing faceted and smooth surfaces was characterized. Realistic anthropomorphic polyhedral brain and torso phantoms were constructed and their use in simulated 3D and two-dimensional (2D) MRI acquisitions was described. Using polyhedra, the Fourier transform of faceted shapes can be computed to within machine precision. Smooth surfaces can be approximated with increasing accuracy by increasing the number of facets in the polyhedron; the additional accumulated numerical imprecision of the Fourier transform of polyhedra with many faces remained small. Simulations of 3D and 2D brain and 2D torso cine acquisitions produced realistic reconstructions free of high frequency edge aliasing compared with equivalent voxelized/rasterized phantoms. Analytical polyhedral phantoms are easy to construct and can accurately simulate shapes of biomedical interest. Magn Reson Med 76:663-678, 2016. © 2015 Wiley Periodicals, Inc. © 2015 Wiley Periodicals, Inc.

  13. 3D dosimetric validation of motion compensation concepts in radiotherapy using an anthropomorphic dynamic lung phantom.

    Science.gov (United States)

    Mann, P; Witte, M; Moser, T; Lang, C; Runz, A; Johnen, W; Berger, M; Biederer, J; Karger, C P

    2017-01-21

    In this study, we developed a new setup for the validation of clinical workflows in adaptive radiation therapy, which combines a dynamic ex vivo porcine lung phantom and three-dimensional (3D) polymer gel dosimetry. The phantom consists of an artificial PMMA-thorax and contains a post mortem explanted porcine lung to which arbitrary breathing patterns can be applied. A lung tumor was simulated using the PAGAT (polyacrylamide gelatin gel fabricated at atmospheric conditions) dosimetry gel, which was evaluated in three dimensions by magnetic resonance imaging (MRI). To avoid bias by reaction with oxygen and other materials, the gel was collocated inside a BAREX(™) container. For calibration purposes, the same containers with eight gel samples were irradiated with doses from 0 to 7 Gy. To test the technical feasibility of the system, a small spherical dose distribution located completely within the gel volume was planned. Dose delivery was performed under static and dynamic conditions of the phantom with and without motion compensation by beam gating. To verify clinical target definition and motion compensation concepts, the entire gel volume was homogeneously irradiated applying adequate margins in case of the static phantom and an additional internal target volume in case of dynamically operated phantom without and with gated beam delivery. MR-evaluation of the gel samples and comparison of the resulting 3D dose distribution with the planned dose distribution revealed a good agreement for the static phantom. In case of the dynamically operated phantom without motion compensation, agreement was very poor while additional application of motion compensation techniques restored the good agreement between measured and planned dose. From these experiments it was concluded that the set up with the dynamic and anthropomorphic lung phantom together with 3D-gel dosimetry provides a valuable and versatile tool for geometrical and dosimetrical validation of motion compensated

  14. Anatomically correct deformable colon phantom

    Science.gov (United States)

    Norris, James A.; Barton, Michael D.; Davis, Brynmor J.; Bieszczad, Jerry; Meunier, Norm L.; Brown, Nathan W.; Kynor, David B.

    2011-03-01

    We describe a technique to build a soft-walled colon phantom that provides realistic lumen anatomy in computed tomography (CT) images. The technique begins with the geometry of a human colon measured during CT colonography (CTC). The three-dimensional air-filled colonic lumen is segmented and then replicated using stereolithography (SLA). The rigid SLA model includes large-scale features (e.g., haustral folds and tenia coli bands) down to small-scale features (e.g., a small pedunculated polyp). Since the rigid model represents the internal air-filled volume, a highly-pliable silicone polymer is painted onto the rigid model. This thin layer of silicone, when removed, becomes the colon wall. Small 3 mm diameter glass beads are affixed to the outer wall. These glass beads show up with high intensity in CT scans and provide a ground truth for evaluating performance of algorithms designed to register prone and supine CTC data sets. After curing, the silicone colon wall is peeled off the rigid model. The resulting colon phantom is filled with air and submerged in a water bath. CT images and intraluminal fly-through reconstructions from CTC scans of the colon phantom are compared against patient data to demonstrate the ability of the phantom to simulate a human colon.

  15. Phantom pain : A sensitivity analysis

    NARCIS (Netherlands)

    Borsje, Susanne; Bosmans, JC; Van der Schans, CP; Geertzen, JHB; Dijkstra, PU

    2004-01-01

    Purpose : To analyse how decisions to dichotomise the frequency and impediment of phantom pain into absent and present influence the outcome of studies by performing a sensitivity analysis on an existing database. Method : Five hundred and thirty-six subjects were recruited from the database of an

  16. Tachyonic field interacting with scalar (phantom) field

    OpenAIRE

    Chattopadhyay, Surajit; Debnath, Ujjal

    2009-01-01

    In this letter, we have considered the universe is filled with the mixture of tachyonic field and scalar or phantom field. If the tachyonic field interacts with scalar or phantom field, the interaction term decays with time and the energy for scalar field is transferred to tachyonic field or the energy for phantom field is transferred to tachyonic field. The tachyonic field and scalar field potentials always decrease, but phantom field potential always increases.

  17. A comparative study on patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2015-01-01

    Full Text Available Purpose: To compare the results of patient specific absolute dosimetry using slab phantom, acrylic body phantom and goat head phantom. Methods: Fifteen intensity modulated radiotherapy (IMRT plans already planned on treatment planning system (TPS for head-and-neck cancer patients were exported on all three kinds of phantoms viz. slab phantom, acrylic body phantom and goat head phantom, and dose was calculated using anisotropic analytic algorithm (AAA. All the gantry angles were set to zero in case of slab phantom while set to as it is in actual plan in case of other two phantoms. All the plans were delivered by linear accelerator (LA and dose for each plan was measured by 0.13 cc ion chamber. The percentage (% variations between planned and measured doses were calculated and analyzed. Results: The mean % variations between planned and measured doses of all IMRT quality assurance (QA plans were as 0.65 (Standard deviation (SD: 0.38 with confidence limit (CL 1.39, 1.16 (SD: 0.61 with CL 2.36 and 2.40 (SD: 0.86 with CL 4.09 for slab phantom, acrylic head phantom and goat head phantom respectively. Conclusion: Higher dose variations found in case of real tissue phantom compare to results in case of slab and acrylic body phantoms. The algorithm AAA does not calculate doses in heterogeneous medium as accurate as it calculates in homogeneous medium. Therefore the patient specific absolute dosimetry should be done using heterogeneous phantom mimicking density wise as well as design wise to the actual human body.  

  18. Phantom Recollection of Bridging and Elaborative Inferences

    Science.gov (United States)

    Singer, Murray; Spear, Jackie

    2015-01-01

    The phantom recollection model is a multiprocess analysis according to which memory judgments are collaboratively supported by one's recollection of an item in its context, a vaguer sense of stimulus familiarity, and the phantom recollection of the substance and even perceptual details of unstudied but related lures. Phantom recollection has…

  19. Glycodendrimers: versatile tools for nanotechnology

    Directory of Open Access Journals (Sweden)

    René Roy

    2013-01-01

    Full Text Available Combining nanotechnology with glycobiology has triggered an exponential growth of research activities in the design of novel functional bionanomaterials (glyconanotechnology. More specifically, recent synthetic advances towards the tailored and versatile design of glycosylated nanoparticles namely glyconanoparticles, considered as synthetic mimetics of natural glycoconjugates, paved the way toward diverse biomedical applications. The accessibility of a wide variety of these structured nanosystems, in terms of shapes, sizes, and organized around stable nanoparticles have readily contributed to their development and applications in nanomedicine. In this context, glycosylated gold-nanoparticles (GNPs, glycosylated quantum dots (QDs, fullerenes, single-wall natotubes (SWNTs, and self-assembled glycononanoparticles using amphiphilic glycopolymers or glycodendrimers have received considerable attention to afford powerful imaging, therapeutic, and biodiagnostic devices. This review will provide an overview of the most recent syntheses and applications of glycodendrimers in glycoscience that have permitted to deepen our understanding of multivalent carbohydrate-protein interactions. Together with synthetic breast cancer vaccines, inhibitors of bacterial adhesions to host tissues including sensitive detection devices, these novel bionanomaterials are finding extensive relevance.

  20. Imidazole: Having Versatile Biological Activities

    Directory of Open Access Journals (Sweden)

    Amita Verma

    2013-01-01

    Full Text Available Imidazoles have occupied a unique position in heterocyclic chemistry, and its derivatives have attracted considerable interests in recent years for their versatile properties in chemistry and pharmacology. Imidazole is nitrogen-containing heterocyclic ring which possesses biological and pharmaceutical importance. Thus, imidazole compounds have been an interesting source for researchers for more than a century. The imidazole ring is a constituent of several important natural products, including purine, histamine, histidine, and nucleic acid. Being a polar and ionisable aromatic compound, it improves pharmacokinetic characteristics of lead molecules and thus is used as a remedy to optimize solubility and bioavailability parameters of proposed poorly soluble lead molecules. There are several methods used for the synthesis of imidazole-containing compounds, and also their various structure reactions offer enormous scope in the field of medicinal chemistry. The imidazole derivatives possess extensive spectrum of biological activities such as antibacterial, anticancer, antitubercular, antifungal, analgesic, and anti-HIV activities. This paper aims to review the biological activities of imidazole during the past years.

  1. Phantom pain in bilateral upper limb amputation.

    Science.gov (United States)

    Modirian, Ehsan; Shojaei, Hadi; Soroush, Mohammad Reza; Masoumi, Mahdi

    2009-01-01

    To alert health professionals on presence and extent of phantom pain and sensation following bilateral upper limb amputation. Of a total of 140 war-related bilateral upper limb amputees in Iran, 103 subjects were thoroughly examined in this cross-sectional study by a physical medicine specialist. The patients were questioned for the presence of phantom pain and sensations, and frequency and intensity of the feeling were recorded. At 17.1 +/- 6.1 years after injury, 82.0% of the 103 amputees suffered from phantom sensation, including varying degrees of phantom limb pain in 53.9% of stumps. Phantom phenomena had a higher frequency in the right extremities, but this was not statistically significant (p > 0.01). Of those amputees who had phantom pain or sensation, 51.2% reported that they 'always' had phantom limb sensation; and approximately one-fourth of the subjects (24.6%) 'always' had phantom pain. Among the stumps who reported phantom pain (N=112), the pain was excruciating (38.5%), distressing (34.9%) or discomforting (25.6%). A significant statistical relation between phantom limb sensation and level of amputation was observed (p phantom pain; medical and surgical modalities only bring temporary relief, and less than 1% of the respondents achieve permanent relief through different treatment methods.

  2. A cochlear implant phantom for evaluating CT acquisition parameters

    Science.gov (United States)

    Chakravorti, Srijata; Bussey, Brian J.; Zhao, Yiyuan; Dawant, Benoit M.; Labadie, Robert F.; Noble, Jack H.

    2017-03-01

    Cochlear Implants (CIs) are surgically implantable neural prosthetic devices used to treat profound hearing loss. Recent literature indicates that there is a correlation between the positioning of the electrode array within the cochlea and the ultimate hearing outcome of the patient, indicating that further studies aimed at better understanding the relationship between electrode position and outcomes could have significant implications for future surgical techniques, array design, and processor programming methods. Post-implantation high resolution CT imaging is the best modality for localizing electrodes and provides the resolution necessary to visually identify electrode position, albeit with an unknown degree of accuracy depending on image acquisition parameters, like the HU range of reconstruction, radiation dose, and resolution of the image. In this paper, we report on the development of a phantom that will both permit studying which CT acquisition parameters are best for accurately identifying electrode position and serve as a ground truth for evaluating how different electrode localization methods perform when using different CT scanners and acquisition parameters. We conclude based on our tests that image resolution and HU range of reconstruction strongly affect how accurately the true position of the electrode array can be found by both experts and automatic analysis techniques. The results presented in this paper demonstrate that our phantom is a versatile tool for assessing how CT acquisition parameters affect the localization of CIs.

  3. Neural correlates of evoked phantom limb sensations.

    Science.gov (United States)

    Andoh, J; Diers, M; Milde, C; Frobel, C; Kleinböhl, D; Flor, H

    2017-05-01

    Previous work showed the existence of changes in the topographic organization within the somatosensory cortex (SI) in amputees with phantom limb pain, however, the link between nonpainful phantom sensations such as cramping or tingling or the percept of the limb and cortical changes is less clear. We used functional magnetic resonance imaging (fMRI) in a highly selective group of limb amputees who experienced inducible and reproducible nonpainful phantom sensations. A standardized procedure was used to locate body sites eliciting phantom sensations in each amputee. Selected body sites that could systematically evoke phantom sensations were stimulated using electrical pulses in order to induce phasic phantom sensations. Homologous body parts were also stimulated in a group of matched controls. Activations related to evoked phantom sensations were found bilaterally in SI and the intraparietal sulci (IPS), which significantly correlated with the intensity of evoked phantom sensations. In addition, we found differences in intra- and interhemispheric interaction between amputees and controls during evoked phantom sensations. We assume that phantom sensations might be associated with a functional decoupling between bilateral SI and IPS, possibly resulting from transcallosal reorganization mechanisms following amputation. Copyright © 2017. Published by Elsevier B.V.

  4. Methanol: A Versatile Fuel for Immediate Use

    Science.gov (United States)

    Reed, T. B.; Lerner, R. M.

    1973-01-01

    Advocates the large-scale production and use of methanol as a substitute for the diminishing reserves of low-cost petroleum resources. Describes the manufacturing process and advantages of the versatile fuel. (JR)

  5. Psychophysical correlates of phantom limb experience.

    Science.gov (United States)

    Katz, J

    1992-01-01

    Phantom limb phenomena were correlated with psychophysiological measures of peripheral sympathetic nervous system activity measured at the amputation stump and contralateral limb. Amputees were assigned to one of three groups depending on whether they reported phantom limb pain, non-painful phantom limb sensations, or no phantom limb at all. Skin conductance and skin temperature were recorded continuously during two 30 minute sessions while subjects continuously monitored and rated the intensity of any phantom limb sensation or pain they experienced. The results from both sessions showed that mean skin temperature was significantly lower at the stump than the contralateral limb in the groups with phantom limb pain and non-painful phantom limb sensations, but not among subjects with no phantom limb at all. In addition, stump skin conductance responses correlated significantly with the intensity of non-painful phantom limb paresthesiae but not other qualities of sensation or pain. Between-limb measures of pressure sensitivity were not significantly different in any group. The results suggest that the presence of a phantom limb, whether painful or painless, is related to the sympathetic-efferent outflow of cutaneous vasoconstrictor fibres in the stump and stump neuromas. The hypothesis of a sympathetic-efferent somatic-afferent mechanism involving both sudomotor and vasoconstrictor fibres is proposed to explain the relationship between stump skin conductance responses and non-painful phantom limb paresthesiae. It is suggested that increases in the intensity of phantom limb paresthesiae follow bursts of sympathetic activity due to neurotransmitter release onto apposing sprouts of large diameter primary afferents located in stump neuromas, and decreases correspond to periods of relative sympathetic inactivity. The results of the study agree with recent suggestions that phantom limb pain is not a unitary syndrome, but a symptom class with each class subserved by

  6. [Phantom limb pain: from physiopathology to prevention].

    Science.gov (United States)

    Roullet, S; Nouette-Gaulain, K; Brochet, B; Sztark, F

    2009-05-01

    First described in 1545, phantom limb pain is a frequent complication after limb amputation, described by 60 to 85% of amputees. Stump pain, phantom limb sensation and phantom limb pain are often combined. Physiopathology is complex and peripheral, medullar and cortical mechanisms are combined. Pharmacological preventive treatments as well as regional anaesthesia techniques have equivalent results. Such treatments must be investigated more precisely as postoperative rehabilitation of amputees mostly depends on pain relief.

  7. Neutron dosimetry in solid water phantom

    Energy Technology Data Exchange (ETDEWEB)

    Benites-Rengifo, Jorge Luis, E-mail: jlbenitesr@prodigy.net.mx [Centro Estatal de Cancerologia de Nayarit, Calzada de la Cruz 118 Sur, Tepic Nayarit, Mexico and Instituto Tecnico Superior de Radiologia, ITEC, Calle Leon 129, Tepic Nayarit (Mexico); Vega-Carrillo, Hector Rene, E-mail: fermineutron@yahoo.com [Universidad Autonoma de Zacatecas, Unidad Academica de Estudios Nucleares, Apdo. postal 336, 98000, Zacatecas, Zac. (Mexico)

    2014-11-07

    The neutron spectra, the Kerma and the absorbed dose due to neutrons were estimated along the incoming beam in a solid water phantom. Calculations were carried out with the MCNP5 code, where the bunker, the phantom and the model of the15 MV LINAC head were modeled. As the incoming beam goes into the phantom the neutron spectrum is modified and the dosimetric values are reduced.

  8. Motor correlates of phantom limb pain.

    Science.gov (United States)

    Kikkert, Sanne; Mezue, Melvin; Henderson Slater, David; Johansen-Berg, Heidi; Tracey, Irene; Makin, Tamar R

    2017-10-01

    Following amputation, individuals ubiquitously report experiencing lingering sensations of their missing limb. While phantom sensations can be innocuous, they are often manifested as painful. Phantom limb pain (PLP) is notorious for being difficult to monitor and treat. A major challenge in PLP management is the difficulty in assessing PLP symptoms, given the physical absence of the affected body part. Here, we offer a means of quantifying chronic PLP by harnessing the known ability of amputees to voluntarily move their phantom limbs. Upper-limb amputees suffering from chronic PLP performed a simple finger-tapping task with their phantom hand. We confirm that amputees suffering from worse chronic PLP had worse motor control over their phantom hand. We further demonstrate that task performance was consistent over weeks and did not relate to transient PLP or non-painful phantom sensations. Finally, we explore the neural basis of these behavioural correlates of PLP. Using neuroimaging, we reveal that slower phantom hand movements were coupled with stronger activity in the primary sensorimotor phantom hand cortex, previously shown to associate with chronic PLP. By demonstrating a specific link between phantom hand motor control and chronic PLP, our findings open up new avenues for PLP management and improvement of existing PLP treatments. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  9. Phantom pain and risk factors : A multivariate analysis

    NARCIS (Netherlands)

    Dijkstra, PU; Geertzen, JHB; Stewart, R; van der Schans, CP

    2002-01-01

    Phantom pain has been given considerable attention in literature. Phantom Pain reduces quality of life, and patients suffering from phantom pain make heavy use of the medical system. Many risk factors have been identified for phantom Pain in univariate analyses, including phantom sensations, stump

  10. Phantom pain and phantom sensations in upper limb amputees : an epidemiological study

    NARCIS (Netherlands)

    Kooijman, CM; Dijkstra, PU; Geertzen, JHB; Elzinga, A; van der Schans, CP

    Phantom pain in subjects with an amputated limb is a well-known problem. However, estimates of the prevalence of phantom pain differ considerably in the literature. Various factors associated with phantom pain have been described including pain before the amputation, gender, dominance, and time

  11. Do you believe in phantoms?

    CERN Multimedia

    Rosaria Marraffino

    2015-01-01

    “Phantoms” are tools that simulate a therapy’s response by mimicking the conditions of the human body. They are required in hadron therapy in order to optimise and verify the therapy before performing it on the patient. The better the phantom, the more accurate the treatment plan and the more effective the therapy. In the framework of the EU-funded project ENTERVISION*, a team of CERN researchers has designed an innovative piece of equipment able to evaluate radiobiology-related parameters in a very accurate way.   The ENTERVISION phantom being tested at HIT. A key challenge in hadron therapy – i.e. the medical use of hadrons to treat cancer – is to evaluate the biological effect of the delivered radiation. This can be achieved by using accurate dosimetry techniques to study the biological response in terms of the dose deposited and other physical parameters of the beam, such as the Linear Energy Transfer (LET). The job of the “phan...

  12. The phantom limb in dreams.

    Science.gov (United States)

    Brugger, Peter

    2008-12-01

    Mulder and colleagues [Mulder, T., Hochstenbach, J., Dijkstra, P. U., Geertzen, J. H. B. (2008). Born to adapt, but not in your dreams. Consciousness and Cognition, 17, 1266-1271.] report that a majority of amputees continue to experience a normally-limbed body during their night dreams. They interprete this observation as a failure of the body schema to adapt to the new body shape. The present note does not question this interpretation, but points to the already existing literature on the phenomenology of the phantom limb in dreams. A summary of published investigations is complemented by a note on phantom phenomena in the dreams of paraplegic patients and persons born without a limb. Integration of the available data allows the recommendation for prospective studies to consider dream content in more detail. For instance, "adaptation" to the loss of a limb can also manifest itself by seeing oneself surrounded by amputees. Such projective types of anosognosia ("transitivism") in nocturnal dreams should also be experimentally induced in normally-limbed individuals, and some relevant techniques are mentioned.

  13. Physical phantom of craniospinal hydrodynamics.

    Science.gov (United States)

    Bouzerar, R; Czosnyka, M; Czosnyka, Z; Balédent, Olivier

    2012-01-01

    Inside the craniospinal system, blood, and cerebrospinal fluid (CSF) interactions occurring through volume exchanges are still not well understood. We built a physical model of this global hydrodynamic system. The main objective was to study, in controlled conditions, CSF-blood interactions to better understand the phenomenon underlying pathogenesis of hydrocephalus. A structure representing the cranium is connected to the spinal channel. The cranium is divided into compartments mimicking anatomical regions such as ventricles or aqueduct cerebri. Resistive and compliant characteristics of blood and CSF compartments can be assessed or measured using pressure and flow sensors incorporated in the model. An arterial blood flow input is generated by a programmable pump. Flows and pressures inside the system are simultaneously recorded. Preliminary results show that the model can mimic venous and CSF flows in response to arterial pressure input. Pulse waveforms and volume flows were measured and confirmed that they partially replicated the data previously obtained with phase-contrast magnetic resonance imaging. The phantom shows that CSF oscillations directly result from arteriovenous flow, and intracranial pressure measurements show that the model obeys an exponential relationship between pressure and intracranial volume expansion. The phantom will be useful to investigate the hydrodynamic hypotheses underlying development of hydrocephalus.

  14. A skull-based multiple dipole phantom for EEG and MEG studies

    Energy Technology Data Exchange (ETDEWEB)

    Spencer, M.E.; Leahy, R.M. [University of Southern California, Los Angeles, CA (United States); Mosher, J.C. [Los Alamos National Lab., NM (United States)

    1996-07-01

    A versatile phantom for use in evaluating forward and inverse methods for MEG and EEG has been designed and is currently being constructed. The phantom consists of three major components: (i) a 32-element cur- rent dipole array, (ii) a PC-controlled dipole driver with 32 isolated channels allowing independent control of each dipole, (iii) spherical and human-skull mounts in which the dipole array is placed. Materials were selected throughout the phantom to produce minimal field distortions and artifacts to enable acquisition of high quality EEG and MEG data. The dipoles are made from a rigid narrow (0.84 mm) stainless steel coax cable. The dipole drivers can be configured as either current or voltage sources, are independently programmable and fully isolated, and are capable of producing arbitrary bipolar waveforms up to a 200 Hz bandwidth. The spherical mount is a single shell sphere filled with conductive gelatin. The human skull mount has three shells: ``brain`` (conducting gelatin), ``skull`` (the skull is impregnated with a low conductivity conducting gelatin), and ``scalp`` (a thin layer of rubber latex mixed with NaCl to achieve a conductivity matched to the brain). The conductivities will be adjusted to achieve approximately an 80:1:80 ratio. Data collected to date from the spherical phantom shows excellent agreement between measured surface potentials and that predicted from theory (27 of the 32 dipoles give better than 99.9% rms fit) and negligible leakage between dipoles. We are currently completing construction of the skull mount.

  15. Synaesthesia in phantom limbs induced with mirrors.

    Science.gov (United States)

    Ramachandran, V S; Rogers-Ramachandran, D

    1996-04-22

    Although there is a vast clinical literature on phantom limbs, there have been no experimental studies on the effects of visual input on phantom sensations. We introduce an inexpensive new device--a 'virtual reality box'--to resurrect the phantom visually to study inter-sensory effects. A mirror is placed vertically on the table so that the mirror reflection of the patient's intact had is 'superimposed' on the felt position of the phantom. We used this procedure on ten patients and found the following results. 1. In six patients, when the normal hand was moved, so that the phantom was perceived to move in the mirror, it was also felt to move; i.e. kinesthetic sensations emerged in the phantom. In D.S. this effect occurred even though he had never experienced any movements in the phantom for ten years before we tested him. He found the return of sensations very enjoyable. 2. Repeated practice led to a permanent 'disappearance' of the phantom arm in patient D.S. and the hand became telescoped into the stump near the shoulder. 3. Using an optical trick, impossible postures--e.g. extreme hyperextension of the fingers--could be induced visually in the phantom. In one case this was felt as a transient 'painful tug' in the phantom. 4. Five patients experienced involuntary painful 'clenching spasms' in the phantom hand and in four of them the spasms were relieved when the mirror was used to facilitate 'opening' of the phantom hand; opening was not possible without the mirror. 5. In three patients, touching the normal hand evoked precisely localized touch sensations in the phantom. Interestingly, the referral was especially pronounced when the patients actually 'saw' their phantom being touched in the mirror. Indeed, in a fourth patient (R.L.) the referral occurred only if he saw his phantom being touched: a curious form of synaesthesia. These experiments lend themselves readily to imaging studies using PET and fMRI. Taken collectively, they suggest that there is a

  16. Synthetic breast phantoms from patient based eigenbreasts.

    Science.gov (United States)

    Sturgeon, Gregory M; Park, Subok; Segars, William Paul; Lo, Joseph Y

    2017-12-01

    The limited number of 3D patient-based breast phantoms available could be augmented by synthetic breast phantoms in order to facilitate virtual clinical trials (VCTs) using model observers for breast imaging optimization and evaluation. These synthetic breast phantoms were developed using Principal Component Analysis (PCA) to reduce the number of dimensions needed to describe a training set of images. PCA decomposed a training set of M breast CT volumes (with millions of voxels each) into an M-1-dimensional space of eigenvectors, which we call eigenbreasts. Each of the training breast phantoms was compactly represented by the mean image plus a weighted sum of eigenbreasts. The distribution of weights observed from training was then sampled to create new synthesized breast phantoms. The resulting synthesized breast phantoms demonstrated a high degree of realism, as supported by an observer study. Two out of three experienced physicist observers were unable to distinguish between the synthesized breast phantoms and the patient-based phantoms. The fibroglandular density and noise power law exponent of the synthesized breast phantoms agreed well with the training data. Our method extends our series of digital breast phantoms based on breast CT data, providing the capability to generate new, statistically varying ensembles consisting of tens of thousands of virtual subjects. This work represents an important step toward conducting future virtual trials for task-based assessment of breast imaging, where it is vital to have a large ensemble of realistic phantoms for statistical power as well as clinical relevance. © 2017 American Association of Physicists in Medicine.

  17. The neural basis of phantom limb pain.

    Science.gov (United States)

    Flor, Herta; Diers, Martin; Andoh, Jamila

    2013-07-01

    A recent study suggests that brain changes in amputees may be pain-induced, questioning maladaptive plasticity as a neural basis of phantom pain. These findings add valuable information on cortical reorganization after amputation. We suggest further lines of research to clarify the mechanisms that underlie phantom pain. Copyright © 2013 Elsevier Ltd. All rights reserved.

  18. Resin phantoms as skin simulating layers

    CSIR Research Space (South Africa)

    Karsten, AE

    2011-07-01

    Full Text Available on the efficiency of Photodynamic Therapy (PDT) treatment. Two resin based solid phantoms were prepared to simulate two different skin types. Cells were prepared and PDT treatment were done on cells with and without the phantoms, by keeping the total dose delivered...

  19. A computational model unifies apparently contradictory findings concerning phantom pain

    National Research Council Canada - National Science Library

    Boström, Kim J; de Lussanet, Marc H E; Weiss, Thomas; Puta, Christian; Wagner, Heiko

    2014-01-01

    ...) as a cause of phantom pain. However, it was recently found that BOLD activity during voluntary movements of the phantom positively correlates with phantom pain rating, giving rise to a model of persistent representation...

  20. [A dynamic phantom for computer tomography].

    Science.gov (United States)

    Nüsslin, F

    1981-06-01

    A phantom is described which has been developed for investigating factors depending on the scanner itself and on the scanned object which potentially influence the kind and the extent of motion artefacts on the CT-image. Additionally, the phantom may be applied to qualify assurance measurements in computer tomography. A cylindrical insert mounted on a motor driven axis is fitted centrally in a cylindrical block machined from lucite. Two interchangeable inserts are available, one containing test objects made of various materials, and another one containing small vessels which can be filled with test solutions. The insert positioned in the phantom can rotate either continuously or with the direction of motion being altered periodically. Speed, frequency and arc can be varied within wide limits. Examples demonstrating the static and the dynamic mode of the phantom are shown. By means of the dynamic phantom it is quite easy to directly determine the scan-time of a Computer tomograph.

  1. Guinea Pigs: Versatile Animals for the Classroom

    Science.gov (United States)

    Barman, Charles R.

    1977-01-01

    Guinea pigs are presented as versatile classroom animals. Suggestions for animal behavior and genetics studies are given. Also included is information concerning sex determination and the breeding of guinea pigs, and hints on keeping these animals in the classroom. References and illustrations complete the article. (MA)

  2. A Versatile Technique for Solving Quintic Equations

    Science.gov (United States)

    Kulkarni, Raghavendra G.

    2006-01-01

    In this paper we present a versatile technique to solve several types of solvable quintic equations. In the technique described here, the given quintic is first converted to a sextic equation by adding a root, and the resulting sextic equation is decomposed into two cubic polynomials as factors in a novel fashion. The resultant cubic equations are…

  3. Versatility of nodal affiliation to communities.

    Science.gov (United States)

    Shinn, Maxwell; Romero-Garcia, Rafael; Seidlitz, Jakob; Váša, František; Vértes, Petra E; Bullmore, Edward

    2017-06-27

    Graph theoretical analysis of the community structure of networks attempts to identify the communities (or modules) to which each node affiliates. However, this is in most cases an ill-posed problem, as the affiliation of a node to a single community is often ambiguous. Previous solutions have attempted to identify all of the communities to which each node affiliates. Instead of taking this approach, we introduce versatility, V, as a novel metric of nodal affiliation: V ≈ 0 means that a node is consistently assigned to a specific community; V > 0 means it is inconsistently assigned to different communities. Versatility works in conjunction with existing community detection algorithms, and it satisfies many theoretically desirable properties in idealised networks designed to maximise ambiguity of modular decomposition. The local minima of global mean versatility identified the resolution parameters of a hierarchical community detection algorithm that least ambiguously decomposed the community structure of a social (karate club) network and the mouse brain connectome. Our results suggest that nodal versatility is useful in quantifying the inherent ambiguity of modular decomposition.

  4. Galactic dark matter in the phantom field

    Science.gov (United States)

    Li, Ming-Hsun; Yang, Kwei-Chou

    2012-12-01

    We investigate the possibility that the galactic dark matter exists in a scenario where the phantom field is responsible for the dark energy. We obtain the statically and spherically approximate solution for this kind of galaxy system with a supermassive black hole at its center. The solution of the metric functions is satisfied with gtt=-grr-1. Constrained by the observation of the rotational stars moving in circular orbits with nearly constant tangential speed in a spiral galaxy, the background of the phantom field which is spatially inhomogeneous has an exponential potential. To avoid the well-known quantum instability of the vacuum at high frequencies, the phantom field defined in an effective theory is valid only at low energies. Under this assumption, we further investigate the following properties. The absorption cross section of the low-energy S-wave excitations of the phantom field into the central black hole is shown to be the horizontal area of the central black hole. Because the infalling phantom particles have a total negative energy, the accretion of the phantom energy is related to the decrease of the black hole mass, which is estimated to be much less than a solar mass in the lifetime of the Universe. Using a simple model with the cold dark matter very weakly coupled to the “low-frequency” phantom particles that are generated from the background, we show that these two densities can be quasistable in the galaxy.

  5. A phantom design for validating colonoscopy tracking

    Science.gov (United States)

    Liu, Jianfei; Subramanian, Kalpathi R.; Yoo, Terry S.

    2012-03-01

    Phantom experiments are useful and frequently used in validating algorithms or techniques in applications where it is difficult or impossible to generate accurate ground-truth. In this work we present a phantom design and experiments to validate our colonoscopy tracking algorithms, that serve to keep both virtual colonoscopy and optical colonoscopy images aligned (in location and orientation). We describe the construction of two phantoms, capable of respectively moving along a straight and a curved path. The phantoms are motorized so as to be able to move at a near constant speed. Experiments were performed at three speeds: 10, 15 and 20mm/sec, to simulate motion velocities during colonoscopy procedures. The average velocity error was within 3mm/sec in both straight and curved phantoms. Displacement error was within 7mm over a total distance of 288mm in the straight phantom, and less than 7mm over 287mm in the curved phantom. Multiple trials were performed of each experiment(and their errors averaged) to ensure repeatability.

  6. The reference phantoms: voxel vs polygon.

    Science.gov (United States)

    Kim, C H; Yeom, Y S; Nguyen, T T; Wang, Z J; Kim, H S; Han, M C; Lee, J K; Zankl, M; Petoussi-Henss, N; Bolch, W E; Lee, C; Chung, B S

    2016-06-01

    The International Commission on Radiological Protection (ICRP) reference male and female adult phantoms, described in Publication 110, are voxel phantoms based on whole-body computed tomography scans of a male and a female patient, respectively. The voxel in-plane resolution and the slice thickness, of the order of a few millimetres, are insufficient for proper segmentation of smaller tissues such as the lens of the eye, the skin, and the walls of some organs. The calculated doses for these tissues therefore present some limitations, particularly for weakly penetrating radiation. Similarly, the Publication 110 phantoms cannot represent 8-40-µm-thick target regions in respiratory or alimentary tract organs. Separate stylised models have been used to represent these tissues for calculation of the ICRP reference dose coefficients (DCs). ICRP Committee 2 recently initiated a research project, the ultimate goal of which is to convert the Publication 110 phantoms to a high-quality polygon-mesh (PM) format, including all source and target regions, even those of the 8-40-µm-thick alimentary and respiratory tract organs. It is expected that the converted phantoms would lead to the same or very similar DCs as the Publication 110 reference phantoms for penetrating radiation and, at the same time, provide more accurate DCs for weakly penetrating radiation and small tissues. Additionally, the reference phantoms in the PM format would be easily deformable and, as such, could serve as a starting point to create phantoms of various postures for use, for example, in accidental dose calculations. This paper will discuss the current progress of the phantom conversion project and its significance for ICRP DC calculations. © The International Society for Prosthetics and Orthotics.

  7. Diffusion of silver during sintering in high permittivity COG dielectrics

    NARCIS (Netherlands)

    Mikkenie, R.; Groen, W.A.; Drift, R. van der

    2010-01-01

    To achieve cost reduction in multi-layer ceramic capacitors and actuators, which use a silver-palladium alloy as internal electrode, the trend is to use alloys with the highest silver content possible. This requires ceramic materials which must be sintered at a relative low temperature. Goal is to

  8. Self-Healing, High-Permittivity Silicone Dielectric Elastomer

    DEFF Research Database (Denmark)

    Madsen, Frederikke Bahrt; Yu, Liyun; Skov, Anne Ladegaard

    2016-01-01

    Currently used dielectric elastomers do not have the ability to self-heal after detrimental events such as tearing or electrical breakdown, which are critical issues in relation to product reliability and lifetime. In this paper, we present a self-healing dielectric elastomer that additionally...... possesses high dielectric permittivity and consists of an interpenetrating polymer network of silicone elastomer and ionic silicone species that are cross-linked through proton exchange between amines and acids. The ionically cross-linked silicone provides self-healing properties after electrical breakdown...

  9. Development of a dynamic 4D anthropomorphic breast phantom for contrast-based breast imaging

    Science.gov (United States)

    Kiarashi, Nooshin; Lin, Yuan; Segars, William P.; Ghate, Sujata V.; Ikejimba, Lynda; Chen, Baiyu; Lo, Joseph Y.; Dobbins, James T., III; Nolte, Loren W.; Samei, Ehsan

    2012-03-01

    Mammography is currently the most widely accepted tool for detection and diagnosis of breast cancer. However, the sensitivity of mammography is reduced in women with dense breast tissue due to tissue overlap, which may obscure lesions. Digital breast tomosynthesis with contrast enhancement reduces tissue overlap and provides additional functional information about lesions (i.e. morphology and kinetics), which in turn may improve lesion characterization. The performance of such techniques is highly dependent on the structural composition of the breast, which varies significantly across patients. Therefore, optimization of breast imaging systems should be done with respect to this patient versatility. Furthermore, imaging techniques that employ contrast require the inclusion of a temporally varying breast composition with respect to the contrast agent kinetics to enable the optimization of the system. To these ends, we have developed a dynamic 4D anthropomorphic breast phantom, which can be used for optimizing a breast imaging system by incorporating material characteristics. The presented dynamic phantom is based on two recently developed anthropomorphic breast phantoms, which can be representative of a whole population through their randomized anatomical feature generation and various compression levels. The 4D dynamic phantom is incorporated with the kinetics of contrast agent uptake in different tissues and can realistically model benign and malignant lesions. To demonstrate the utility of the proposed dynamic phantom, contrast-enhanced digital mammography and breast tomosynthesis were simulated where a ray-tracing algorithm emulated the projections, a filtered back projection algorithm was used for reconstruction, and dual-energy and temporal subtractions were performed and compared.

  10. Can neural blocks prevent phantom limb pain?

    Science.gov (United States)

    Borghi, Battista; D'Addabbo, Marco; Borghi, Raffaele

    2014-07-01

    Phantom limb syndrome (PLS) is a syndrome including stump pain, phantom limb pain and not-painful phantom sensations, which involves a large part of amputee patients and often has devastating effects on their quality of life. The efficacy of standard therapies is very poor. Nerve blocks have been investigated for the treatment and prevention of PLS. Epidural and peripheral blocks limited to the first three postamputation days can only reduce acute pain but cannot prevent the later development of PLS. Recent studies have shown that ambulatory prolonged peripheral nerve block (up to 30 days postamputation) may represent a new possible option to treat phantom pain and prevent the development of PLS and chronic pain.

  11. Phantom perception: voluntary and involuntary nonretinal vision.

    Science.gov (United States)

    Pearson, Joel; Westbrook, Fred

    2015-05-01

    Hallucinations, mental imagery, synesthesia, perceptual filling-in, and many illusions are conscious visual experiences without a corresponding retinal stimulus: what we call 'phantom perception'. Such percepts show that our experience of the world is not solely determined by direct sensory input. Some phantom percepts are voluntary, whereas others are involuntarily, occurring automatically. Here, by way of review, we compare and contrast these two types of phantom perception and their neural representations. We propose a dichotomous framework for phantom vision, analogous to the subtypes of attention: endogenous and exogenous. This framework unifies findings from different fields and species, providing a guide to study the constructive nature of conscious sensory perception. Copyright © 2015 Elsevier Ltd. All rights reserved.

  12. The effect of phantom parent groups on genetic trend estimation ...

    African Journals Online (AJOL)

    Bias in the estimation of trend was reduced when phantom parent groups were taken into account. The 109 385 base animals were replaced by 64 phantom parent groups. Phantom parent groups were constructed by combining year of birth, country of birth and selection intensity of the phantom parents. In recent years ...

  13. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data.

    Science.gov (United States)

    Kiarashi, Nooshin; Nolte, Adam C; Sturgeon, Gregory M; Segars, William P; Ghate, Sujata V; Nolte, Loren W; Samei, Ehsan; Lo, Joseph Y

    2015-07-01

    Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power-law descriptions of the phantom images

  14. Acupuncture treatment of phantom limb pain and phantom limb sensation in a primary care setting.

    Science.gov (United States)

    Davies, Arwel

    2013-03-01

    A 45-year-old man presented with phantom limb pain and phantom limb sensation 12 weeks after an above-elbow amputation of his right arm. He underwent seven sessions of acupuncture at weekly intervals carried out by his general practitioner on his intact left arm, with complete relief of the phantom limb pain and considerable improvement of the phantom limb sensation of his right arm. This case demonstrates the possible benefits from the use of short acupuncture sessions for a potentially chronic condition undertaken within the constraints of a busy general medical practice.

  15. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    Energy Technology Data Exchange (ETDEWEB)

    Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Nolte, Adam C. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Sturgeon, Gregory M.; Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Segars, William P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Nolte, Loren W. [Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Department of Physics, Duke University, Durham, North Carolina 27708 (United States); and others

    2015-07-15

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  16. Conversion of ICRP male reference phantom to polygon-surface phantom.

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-07

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom for highly penetrating radiations such as

  17. Conversion of ICRP male reference phantom to polygon-surface phantom

    Science.gov (United States)

    Yeom, Yeon Soo; Han, Min Cheol; Kim, Chan Hyeong; Jeong, Jong Hwi

    2013-10-01

    The International Commission on Radiological Protection (ICRP) reference phantoms, developed based on computed tomography images of human bodies, provide much more realism of human anatomy than the previously used MIRD5 (Medical Internal Radiation Dose) mathematical phantoms. It has been, however, realized that the ICRP reference phantoms have some critical limitations showing a considerable amount of holes for the skin and wall organs mainly due to the nature of voxels of which the phantoms are made, especially due to their low voxel resolutions. To address this problem, we are planning to develop the polygon-surface version of ICRP reference phantoms by directly converting the ICRP reference phantoms (voxel phantoms) to polygon-surface phantoms. The objective of this preliminary study is to see if it is indeed possible to construct the high-quality polygon-surface phantoms based on the ICRP reference phantoms maintaining identical organ morphology and also to identify any potential issues, and technologies to address these issues, in advance. For this purpose, in the present study, the ICRP reference male phantom was roughly converted to a polygon-surface phantom. Then, the constructed phantom was implemented in Geant4, Monte Carlo particle transport code, for dose calculations, and the calculated dose values were compared with those of the original ICRP reference phantom to see how much the calculated dose values are sensitive to the accuracy of the conversion process. The results of the present study show that it is certainly possible to convert the ICRP reference phantoms to surface phantoms with enough accuracy. In spite of using relatively less resources (<2 man-months), we were able to construct the polygon-surface phantom with the organ masses perfectly matching the ICRP reference values. The analysis of the calculated dose values also implies that the dose values are indeed not very sensitive to the detailed morphology of the organ models in the phantom

  18. Mirror Therapy for Phantom Limb Pain

    OpenAIRE

    Kim, Sae Young; Kim, Yun Young

    2012-01-01

    Phantom limb pain is a painful sensation that is perceived in a body part that no longer exists. To control this pain, many methods have been used such as medication, physical treatment, nerve block, neuromodulation, surgical treatment and mirror therapy. However, until now, there effects have been uncertain. We report the successful reduction of phantom limb pain using mirror therapy when other treatments initially failed to control the pain.

  19. Cyclic universe due to phantom and quintessence

    OpenAIRE

    Gao, Changjun; Lu, Youjun; Shen, You-Gen

    2014-01-01

    We explore a cyclic universe due to phantom and quintessence fields. We find that, in every cycle of the evolution of the universe, the phantom dominates the cosmic early history and quintessence dominates the cosmic far future. In this model of universe, there are infinite cycles of expansion and contraction. Different from the inflationary universe, the corresponding cosmic space-time is geodesically complete and quantum stable. But similar to the Cyclic Model, the flatness problem, the hor...

  20. The menacing phantom: what pulls the trigger?

    Science.gov (United States)

    Giummarra, Melita J; Georgiou-Karistianis, Nellie; Nicholls, Michael E R; Gibson, Stephen J; Chou, Michael; Bradshaw, John L

    2011-08-01

    Phantom phenomena are frequent following amputation, but how this often painful experience is modified or triggered by spontaneous events or sensations often puzzles amputees and clinicians alike. We explored triggers of phantom phenomena in a heterogeneous sample of 264 upper and lower limb adult amputees with phantom sensations. Participants completed a structured questionnaire to determine the prevalence and nature of the triggers of phantom phenomena. The four categories of triggers identified include: (a) a quarter of participants experiencing psychological, emotional or autonomic triggers; (b) half experiencing behavioral triggers, "forgetting" the limb's absence and attempting to use the phantom; (c) one-fifth experiencing weather-induced triggers; and (d) one-third experiencing sensations referred from parts of the body. Upper limb amputees; and were more likely to experience weather-induced phantom phenomena than lower limb amputees; and upper and lower limb amputees were equally likely to experience referred sensations from the genitals, contradicting the homuncular remapping hypothesis. Traumatic amputees were more likely to report emotional triggers. Further, while those with emotional triggers exhibited poorer acceptance of the limitations of amputation, they were more likely to employ adaptive coping mechanisms. Finally, habitual "forgetting" behaviors were most common soon after amputation, whereas other more adaptive schemata (e.g., self-defense) were equally likely to be performed at any time following amputation. Various likely inter-related mechanisms are discussed in relation to phantom triggers. Ultimately, optimizing stump and neuroma management, as well as restoring function of central networks for pain, limb movement, and amputation-related memories, should help manage spontaneously triggered phantom phenomena. Copyright © 2011 European Federation of International Association for the Study of Pain Chapters. All rights reserved.

  1. Phantom Limb Pain: Mechanisms and Treatment Approaches

    Science.gov (United States)

    Subedi, Bishnu; Grossberg, George T.

    2011-01-01

    The vast amount of research over the past decades has significantly added to our knowledge of phantom limb pain. Multiple factors including site of amputation or presence of preamputation pain have been found to have a positive correlation with the development of phantom limb pain. The paradigms of proposed mechanisms have shifted over the past years from the psychogenic theory to peripheral and central neural changes involving cortical reorganization. More recently, the role of mirror neurons in the brain has been proposed in the generation of phantom pain. A wide variety of treatment approaches have been employed, but mechanism-based specific treatment guidelines are yet to evolve. Phantom limb pain is considered a neuropathic pain, and most treatment recommendations are based on recommendations for neuropathic pain syndromes. Mirror therapy, a relatively recently proposed therapy for phantom limb pain, has mixed results in randomized controlled trials. Most successful treatment outcomes include multidisciplinary measures. This paper attempts to review and summarize recent research relative to the proposed mechanisms of and treatments for phantom limb pain. PMID:22110933

  2. Phantom Limb Pain: Mechanisms and Treatment Approaches

    Directory of Open Access Journals (Sweden)

    Bishnu Subedi

    2011-01-01

    Full Text Available The vast amount of research over the past decades has significantly added to our knowledge of phantom limb pain. Multiple factors including site of amputation or presence of preamputation pain have been found to have a positive correlation with the development of phantom limb pain. The paradigms of proposed mechanisms have shifted over the past years from the psychogenic theory to peripheral and central neural changes involving cortical reorganization. More recently, the role of mirror neurons in the brain has been proposed in the generation of phantom pain. A wide variety of treatment approaches have been employed, but mechanism-based specific treatment guidelines are yet to evolve. Phantom limb pain is considered a neuropathic pain, and most treatment recommendations are based on recommendations for neuropathic pain syndromes. Mirror therapy, a relatively recently proposed therapy for phantom limb pain, has mixed results in randomized controlled trials. Most successful treatment outcomes include multidisciplinary measures. This paper attempts to review and summarize recent research relative to the proposed mechanisms of and treatments for phantom limb pain.

  3. The GSF family of voxel phantoms.

    Science.gov (United States)

    Petoussi-Henss, Nina; Zanki, Maria; Fill, Ute; Regulla, Dieter

    2002-01-07

    Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to introduce the GSF voxel phantoms, with emphasis on the new ones and highlight their characteristics and limitations. The GSF voxel family includes at the moment two paediatric and five adult phantoms of both sexes, different ages and stature and several others are under construction. Two phantoms made of physical calibration phantoms are also available to be used for validation purposes. The GSF voxel phantoms tend to cover persons of individual anatomy and were developed to be used for numerical dosimetry of radiation transport but other applications are also possible. Examples of applications in patient dosimetry in diagnostic radiology and in nuclear medicine as well as for whole-body irradiations from idealized external exposures are given and discussed.

  4. The GSF family of voxel phantoms

    Science.gov (United States)

    Petoussi-Henss, Nina; Zankl, Maria; Fill, Ute; Regulla, Dieter

    2002-01-01

    Voxel phantoms are human models based on computed tomographic or magnetic resonance images obtained from high-resolution scans of a single individual. They consist of a huge number of volume elements (voxels) and are at the moment the most precise representation of the human anatomy. The purpose of this paper is to introduce the GSF voxel phantoms, with emphasis on the new ones and highlight their characteristics and limitations. The GSF voxel family includes at the moment two paediatric and five adult phantoms of both sexes, different ages and stature and several others are under construction. Two phantoms made of physical calibration phantoms are also available to be used for validation purposes. The GSF voxel phantoms tend to cover persons of individual anatomy and were developed to be used for numerical dosimetry of radiation transport but other applications are also possible. Examples of applications in patient dosimetry in diagnostic radiology and in nuclear medicine as well as for whole-body irradiations from idealized external exposures are given and discussed.

  5. A nonlinear elasticity phantom containing spherical inclusions

    Science.gov (United States)

    Pavan, Theo Z.; Madsen, Ernest L.; Frank, Gary R.; Jiang, Jingfeng; Carneiro, Antonio A. O.; Hall, Timothy J.

    2012-08-01

    The strain image contrast of some in vivo breast lesions changes with increasing applied load. This change is attributed to differences in the nonlinear elastic properties of the constituent tissues suggesting some potential to help classify breast diseases by their nonlinear elastic properties. A phantom with inclusions and long-term stability is desired to serve as a test bed for nonlinear elasticity imaging method development, testing, etc. This study reports a phantom designed to investigate nonlinear elastic properties with ultrasound elastographic techniques. The phantom contains four spherical inclusions and was manufactured from a mixture of gelatin, agar and oil. The phantom background and each of the inclusions have distinct Young's modulus and nonlinear mechanical behavior. This phantom was subjected to large deformations (up to 20%) while scanning with ultrasound, and changes in strain image contrast and contrast-to-noise ratio between inclusion and background, as a function of applied deformation, were investigated. The changes in contrast over a large deformation range predicted by the finite element analysis (FEA) were consistent with those experimentally observed. Therefore, the paper reports a procedure for making phantoms with predictable nonlinear behavior, based on independent measurements of the constituent materials, and shows that the resulting strain images (e.g., strain contrast) agree with that predicted with nonlinear FEA.

  6. Silicone breast phantoms for elastographic imaging evaluation.

    Science.gov (United States)

    Kashif, Amer S; Lotz, Thomas F; McGarry, Matthew D; Pattison, Adam J; Chase, James G

    2013-06-01

    Breast cancer is a major public health issue for women, and early detection significantly increases survival rate. Currently, there is increased research interest in elastographic soft-tissue imaging techniques based on the correlation between pathology and mechanical stiffness. Anthropomorphic breast phantoms are critical for ex vivo validation of emerging elastographic technologies. This research develops heterogeneous breast phantoms for use in testing elastographic imaging modalities. Mechanical property estimation of eight different elastomers is performed to determine storage moduli (E') and damping ratios (ζ) using a dynamic mechanical analyzer. Dynamic compression testing was carried out isothermally at room temperature over a range of 4-50 Hz. Silicone compositions with physiologically realistic storage modulus were chosen for mimicking skin adipose, cancerous tumors, and pectoral muscles and 13 anthropomorphic breast phantoms were constructed for ex vivo trials of digital image elastotomography (DIET) breast cancer screening system. A simpler fabrication was used to assess the possibility of multiple tumor detection using magnetic resonance elastography (MRE). Silicone materials with ranges of storage moduli (E') from 2 to 570 kPa and damping ratios (ζ) from 0.03 to 0.56 were identified. The resulting phantoms were tested in two different elastographic breast cancer diagnostic modalities. A significant contrast was successfully identified between healthy tissues and cancerous tumors both in MRE and DIET. The phantoms presented promise aid to researchers in elastographic imaging modalities for breast cancer detection and provide a foundation for silicone based phantom materials for mimicking soft tissues of other human organs.

  7. The Versatile Link Demo Board (VLDB)

    Science.gov (United States)

    Martín Lesma, R.; Alessio, F.; Barbosa, J.; Baron, S.; Caplan, C.; Leitao, P.; Pecoraro, C.; Porret, D.; Wyllie, K.

    2017-02-01

    The Versatile Link Demonstrator Board (VLDB) is the evaluation kit for the radiation-hard Optical Link ecosystem, which provides a 4.8 Gbps data transfer link for communication between front-end (FE) and back-end (BE) of the High Energy Physics experiments. It gathers the Versatile link main radiation-hard custom Application-Specific Integrated Circuits (ASICs) and modules: GBTx, GBT-SCA and VTRx/VTTx plus the FeastMP, a radiation-hard in-house designed DC-DC converter. This board is the first design allowing system-level tests of the Link with a complete interconnection of the constitutive components, allowing data acquisition, control and monitoring of FE devices with the GBT-SCA pair.

  8. How versatile are inositol phosphate kinases?

    OpenAIRE

    Shears, Stephen B.

    2004-01-01

    This review assesses the extent and the significance of catalytic versatility shown by several inositol phosphate kinases: the inositol phosphate multikinase, the reversible Ins(1,3,4) P (3)/Ins(3,4,5,6) P (4) kinase, and the kinases that synthesize diphosphoinositol polyphosphates. Particular emphasis is placed upon data that are relevant to the situation in vivo. It will be shown that catalytic promiscuity towards different inositol phosphates is not typically an evolutionary compromise, bu...

  9. Isatin, a versatile molecule: studies in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Silva, Barbara, E-mail: barbara.iq@gmail.com [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2013-05-15

    Isatin is a small, versatile and widely applicable pharmacological molecule. These characteristics make isatin and its derivatives attractive to many research groups as resources for chemical and pharmacological studies. Although it has a relatively simple structure, isatin is a useful chemical scaffold for a variety of chemical transformations. This article discusses several studies performed by Brazilian groups, including investigations of its structural changes, biological assay designs and new methods for the synthesis of isatin. (author)

  10. Toward a reference standard for tissue phantoms

    Science.gov (United States)

    Di Ninni, Paola; Martelli, Fabrizio; Zaccanti, Giovanni

    2011-03-01

    A reference standard for tissue-simulating phantoms, i.e., a phantom with well known and stable optical properties, reproducible, and easy to be found, would be very useful for many applications based on measurements of diffused light. Although many tissue-equivalent phantoms have been proposed, to our knowledge none of them has been characterized sufficiently well to be suggested as a reference standard. Based on the results of measurements of optical properties we carried out at visible and NIR wavelengths, the use of Intralipid 20% diluted in water as diffusive medium, and of India ink as absorber, is here suggested as a first step towards a diffusive reference standard for tissue-simulating phantoms. As for Intralipid 20%, measurements carried out on samples from nine different batches with expiry dates spreading over ten years showed surprisingly small batch-to-batch variations. For the reduced scattering coefficient the maximum deviation from the value averaged over the nine batches was of about 2%, and the results for the absorption coefficient were very close to those for pure water. As for India ink measurements on samples from different batches and from five different brands showed large inter-brand and inter-batch variations for both the absorption and the extinction coefficient. On the contrary, small variations have been observed for the ratio between the absorption and the extinction coefficient. Intralipid 20% and Indian ink can be therefore easily mixed to obtain liquid phantoms with well known optical properties. This phantom can be a first step towards a reference standard for optical tissue phantoms.

  11. Pharmacological interventions for phantom limb pain.

    Science.gov (United States)

    Fang, Jun; Lian, Yan-hong; Xie, Kang-jie; Cai, Shu-nü

    2013-02-01

    To review the mechanisms and current clinical application of pharmacological interventions for phantom limb pain. Both Chinese and English language literatures were searched using MEDLINE (1982 - 2011), Pubmed (1982 - 2011) and the Index of Chinese Language Literature (1982 - 2011). Data from published articles about pharmacological management of phantom limb pain in recent domestic and foreign literature were selected. Data extraction Data were mainly extracted from 96 articles which are listed in the reference section of this review. By reviewing the mechanisms and current clinical application of pharmacological interventions for phantom limb pain, including anticonvulsants, antidepressants, local anaesthetics, N-methyl-D-aspartate receptor antagonists, non-steroidal anti-inflammatory drugs, tramadol, opioids, calcitonin, capsaicin, beta-adrenergic blockers, clonidine, muscle relaxants, and emerging drugs, we examined the efficacy and safety of these medications, outlined the limitations and future directions. Although there is lack of evidence-based consensus guidelines for the pharmacological management of phantom limb pain, we recommend tricyclic antidepressants, gabapentin, tramadol, opioids, local anaesthetics and N-methyl-D-aspartate receptor antagonists as the rational options for the treatment of phantom limb pain.

  12. Innovative anisotropic phantoms for calibration of diffusion tensor imaging sequences.

    Science.gov (United States)

    Kłodowski, Krzysztof; Krzyżak, Artur Tadeusz

    2016-05-01

    The paper describes a novel type of anisotropic phantoms designed for b-matrix spatial distribution diffusion tensor imaging (BSD-DTI). Cubic plate anisotropic phantom, cylinder capillary phantom and water reference phantom are described as a complete set necessary for calibration, validation and normalization of BSD-DTI. An innovative design of the phantoms basing on enclosing the anisotropic cores in glass balls filled with liquid made for the first time possible BSD calibration with usage of echo planar imaging (EPI) sequence. Susceptibility artifacts prone to occur in EPI sequences were visibly reduced in the central region of the phantoms. The phantoms were designed for usage in a clinical scanner's head coil, but can be scaled for other coil or scanner types. The phantoms can be also used for a pre-calibration of imaging of other types of phantoms having more specific applications. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. Tissue-simulating phantoms for assessing potential near-infrared fluorescence imaging applications in breast cancer surgery.

    Science.gov (United States)

    Pleijhuis, Rick; Timmermans, Arwin; De Jong, Johannes; De Boer, Esther; Ntziachristos, Vasilis; Van Dam, Gooitzen

    2014-09-19

    Inaccuracies in intraoperative tumor localization and evaluation of surgical margin status result in suboptimal outcome of breast-conserving surgery (BCS). Optical imaging, in particular near-infrared fluorescence (NIRF) imaging, might reduce the frequency of positive surgical margins following BCS by providing the surgeon with a tool for pre- and intraoperative tumor localization in real-time. In the current study, the potential of NIRF-guided BCS is evaluated using tissue-simulating breast phantoms for reasons of standardization and training purposes. Breast phantoms with optical characteristics comparable to those of normal breast tissue were used to simulate breast conserving surgery. Tumor-simulating inclusions containing the fluorescent dye indocyanine green (ICG) were incorporated in the phantoms at predefined locations and imaged for pre- and intraoperative tumor localization, real-time NIRF-guided tumor resection, NIRF-guided evaluation on the extent of surgery, and postoperative assessment of surgical margins. A customized NIRF camera was used as a clinical prototype for imaging purposes. Breast phantoms containing tumor-simulating inclusions offer a simple, inexpensive, and versatile tool to simulate and evaluate intraoperative tumor imaging. The gelatinous phantoms have elastic properties similar to human tissue and can be cut using conventional surgical instruments. Moreover, the phantoms contain hemoglobin and intralipid for mimicking absorption and scattering of photons, respectively, creating uniform optical properties similar to human breast tissue. The main drawback of NIRF imaging is the limited penetration depth of photons when propagating through tissue, which hinders (noninvasive) imaging of deep-seated tumors with epi-illumination strategies.

  14. Effective and versatile software beamformation toolbox

    DEFF Research Database (Denmark)

    Kortbek, Jacob; Nikolov, Svetoslav; Jensen, Jørgen Arendt

    2007-01-01

    aperture to obtain a preferred constant F-number. An effective and versatile software toolbox for off-line beamformation designed to address all of these issues has been developed. It is capable of exploiting parallelization of computations on a Linux cluster and is written in C++ with a MATLAB (Math Works...... and stored in lookup-tables (LUT). Parametric beamforming can also be applied where calculations are done by demand, thus, reducing the storage demand dramatically. On a standard PC with a Pentium 4, 2.66 GHz processor running Linux the toolbox can beamform 100,000 points in lines of various directions in 20...

  15. Cosmological perturbations in transient phantom inflation scenarios

    Energy Technology Data Exchange (ETDEWEB)

    Richarte, Martin G. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil); Universidad de Buenos Aires, Ciudad Universitaria 1428, Departamento de Fisica, Facultad de Ciencias Exactas y Naturales, Buenos Aires (Argentina); Kremer, Gilberto M. [Universidade Federal do Parana, Departamento de Fisica, Caixa Postal 19044, Curitiba (Brazil)

    2017-01-15

    We present a model of inflation where the inflaton is accommodated as a phantom field which exhibits an initial transient pole behavior and then decays into a quintessence field which is responsible for a radiation era. We must stress that the present unified model only deals with a single field and that the transition between the two eras is achieved in a smooth way, so the model does not suffer from the eternal inflation issue. We explore the conditions for the crossing of the phantom divide line within the inflationary era along with the structural stability of several critical points. We study the behavior of the phantom field within the slow-climb approximation along with the necessary conditions to have sufficient inflation. We also examine the model at the level of classical perturbations within the Newtonian gauge and determine the behavior of the gravitational potential, contrast density and perturbed field near the inflation stage and the subsequent radiation era. (orig.)

  16. Photoacoustic investigation of a neonatal skull phantom

    Science.gov (United States)

    Volinski, Bridget; Hariri, Ali; Fatima, Afreen; Xu, Qiuyun; Nasiriavanaki, Mohammadreza

    2017-03-01

    There is a need for continued research into the diagnosis, prevention and cure of neonatal brain disease and disorders. These disorders lead to fatalities and developmental disorders in infants. Non-invasive imaging techniques are being researched for this purpose. However, the availability of neonatal skull samples for this work is very low. A phantom can be used to simulate the neonatal skull and brain to improve imaging techniques. This study selects a phantom of polyurethane and titanium dioxide and proves its value as a replacement for neonatal skull in research. The methods used for this proof are validation of choice against the literature, transmissivity and acoustic experimentation compared to existing literature, and finally photoacoustic evaluation of the final choice to show its usefulness as a neonatal skull phantom.

  17. MRI phantoms - are there alternatives to agar?

    Directory of Open Access Journals (Sweden)

    Alexandra Hellerbach

    Full Text Available The suitability of different gelling agents as MRI phantoms was evaluated in terms of homogeneity, gel stability and reproducibility. Time and effort for preparation were also taken into account. The relaxation times of various gel compositions were estimated. Carbomer-980 and Carbopol-974P were determined to be promising novel phantom materials. These gelling agents are readily available, inexpensive and easy to handle given that thermal treatment is not required. Furthermore, the viscoelasticity of their polymer network is pH-dependent. With such characteristics, it was even possible to embed sensitive objects and retrieve them after testing. This was demonstrated with a fiber phantom for Diffusion Weighted MRI applications. Since Carbomer-980 and Carbopol-974P are non-hazardous, they are also suitable for multimodal setups (e.g., MRI as well as ultrasonic imaging.

  18. New polymer-based phantom for photoacoustic imaging

    Science.gov (United States)

    Kawaguchi, Yasushi; Iwazaki, Hideaki; Ida, Taiichiro; Nishi, Taiji; Tanikawa, Yukari; Nitta, Naotaka

    2014-03-01

    We will report newly developed polymer-based phantom for photoacoustic (PA) imaging systems. Phantoms are important for performance evaluation and calibration of new modalities; however, there is no established method for making phantoms with no long-term change. We have developed skin mimicking phantoms simulating both optical and acoustic properties (i.e. optical scattering and absorption coefficients, and sound velocity). Furthermore, the phantoms are able to give accurate simulation of blood vessels by Inkjet-printing. Newly developed phantoms are consisted of castor oil included acrylic block copolymer and we can fabricate 0.8mm or less thick sheets and pile them using their self-adhesiveness.

  19. Structured movement representations of a phantom limb associated with phantom limb pain.

    Science.gov (United States)

    Osumi, Michihiro; Sumitani, Masahiko; Wake, Naoki; Sano, Yuko; Ichinose, Akimichi; Kumagaya, Shin-Ichiro; Kuniyoshi, Yasuo; Morioka, Shu

    2015-09-25

    The relation between phantom limb pain (PLP) and the movement representation of a phantom limb remains controversial in several areas of neurorehabilitation, although there are a few studies in which the representation of phantom limb movement was precisely evaluated. We evaluated the structured movement representation of a phantom limb objectively using a bimanual circle-line coordination task. We then investigated the relation between PLP and the structured movement representation. Nine patients with a brachial plexus avulsion injury were enrolled who perceived a phantom limb and had neuropathic pain. While blindfolded, the participants repeatedly drew vertical lines using the intact hand and intended to draw circles using the phantom limb simultaneously. "Drawing of circles" by the phantom limb resulted in an oval transfiguration of the vertical lines ("bimanual coupling" effect). We used an arbitrary ovalization index (OI) to quantify the oval transfiguration. When the OI neared 100%, the trajectory changed toward becoming more circular. A significant negative correlation was observed between the intensity of PLP and the OI (r=-0.66, pphantom limb are necessary for alleviating PLP. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  20. [Phantom limb pain. Psychological treatment strategies].

    Science.gov (United States)

    Diers, M; Flor, H

    2013-04-01

    Similar to other pain syndromes phantom limb pain is characterized by learning and memory processes that maintain the pain and increase maladaptive plastic changes of the brain: therefore, psychological interventions that change maladaptive memory processes are useful. In addition to traditional psychological interventions, such as pain management training and biofeedback, more recent developments that involve sensory discrimination training, mirror treatment, graded motor imagery, prosthesis training and training in virtual reality are interesting. These interventions not only reduce phantom limb pain but also reverse the associated maladaptive brain changes.

  1. Successful peripheral neuromodulation for phantom limb pain.

    Science.gov (United States)

    Cornish, Philip; Wall, Cindy

    2015-04-01

    For decades, the heterogeneity of the amputee population and the complex interaction of biopsychosocial factors have confounded researchers' attempts to develop an effective treatment for phantom limb pain. Therefore, it remains difficult to treat, and affected patients often experience decreased quality of life, increased psychological distress, and poorer health outcomes. In the case study, we report a novel strategy for the peripheral placement of neuromodulation leads for the treatment of phantom limb pain in a patient who subsequently described complete and consistent pain relief independent of significant variations in psychosocial stress. Wiley Periodicals, Inc.

  2. Static phantom wormholes of finite size

    Science.gov (United States)

    Cataldo, Mauricio; Orellana, Fabian

    2017-09-01

    In this paper we derive new static phantom traversable wormholes by assuming a shape function with a quadratic dependence on the radial coordinate r . We mainly focus our study on wormholes sustained by exotic matter with positive energy density (as seen by any static observer) and a variable equation of state pr/ρ wormhole spacetimes extending to infinity, we show that a quadratic shape function allows us to construct static spacetimes of finite size, composed of a phantom wormhole connected to an anisotropic spherically symmetric distribution of dark energy. The wormhole part of the full spacetime does not fulfill the dominant energy condition, while the dark energy part does.

  3. The phantom and the supernumerary phantom limb: historical review and new case.

    Science.gov (United States)

    Cipriani, Gabriele; Picchi, Lucia; Vedovello, Marcella; Nuti, Angelo; Fiorino, Mario Di

    2011-12-01

    The way we experience the world is determined by the way our brain works. The phantom limb phenomenon, which is a delusional belief of the presence of a non-existent limb, has a particular fascination in neurology. This positive phenomenon of the phantom limb raises theoretical questions about its nature. After a stroke, some patients experience the perception of an extra limb in addition to the regular set of two arms and two legs. This complex cognitive and perceptual distortion is called supernumerary phantom limb. Here, we review the pathogenesis and historical aspects, and report a new case.

  4. Support for Conference Entitled The Fifth PHANTOM Users Group Workshop

    National Research Council Canada - National Science Library

    Reinig, Karl

    2001-01-01

    The Fifth PHANToM Users Group (PUG2000) brought together, in an intimate setting, participants who are actively engaged in making computer haptics practical and useful through the use of the PHANTOM Haptic Interface...

  5. A computational model unifies apparently contradictory findings concerning phantom pain

    Science.gov (United States)

    Boström, Kim J.; de Lussanet, Marc H. E.; Weiss, Thomas; Puta, Christian; Wagner, Heiko

    2014-06-01

    Amputation often leads to painful phantom sensations, whose pathogenesis is still unclear. Supported by experimental findings, an explanatory model has been proposed that identifies maladaptive reorganization of the primary somatosensory cortex (S1) as a cause of phantom pain. However, it was recently found that BOLD activity during voluntary movements of the phantom positively correlates with phantom pain rating, giving rise to a model of persistent representation. In the present study, we develop a physiologically realistic, computational model to resolve the conflicting findings. Simulations yielded that both the amount of reorganization and the level of cortical activity during phantom movements were enhanced in a scenario with strong phantom pain as compared to a scenario with weak phantom pain. These results suggest that phantom pain, maladaptive reorganization, and persistent representation may all be caused by the same underlying mechanism, which is driven by an abnormally enhanced spontaneous activity of deafferented nociceptive channels.

  6. Versatile and Extensible, Continuous-Thrust Trajectory Optimization Tool Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop an innovative, versatile and extensible, continuous-thrust trajectory optimization tool for planetary mission design and optimization of...

  7. Phantom breast sensations are frequent after mastectomy

    DEFF Research Database (Denmark)

    Hansen, Dorthe Marie Helbo; Kehlet, Henrik; Gärtner, Rune

    2011-01-01

    Phantom breast sensation (PBS) following mastectomy has been recognized for many years. PBS is a feeling that the removed breast is still there. The reported prevalence and risk factors have not been established in large well-defined patient series. The purpose of this study was to examine...... the prevalence of PBS following mastectomy and associated risk factors....

  8. Phantoms for Radiation Measurements of Mobile Phones

    DEFF Research Database (Denmark)

    Pedersen, Gert Frølund

    2001-01-01

    Measurements of radiation efficiency for a handheld phone equipped with a patch and a helical antenna operated near the human user have been performed. Both measurements include a simple head plus hand phantom and live persons are considered. The position of the hand on the phone is found...

  9. Phantom breast sensations are frequent after mastectomy

    DEFF Research Database (Denmark)

    Hansen, Dorthe Marie Helbo; Kehlet, Henrik; Gærtner, Rune

    2011-01-01

    Phantom breast sensation (PBS) following mastectomy has been recognized for many years. PBS is a feeling that the removed breast is still there. The reported prevalence and risk factors have not been established in large well-defined patient series. The purpose of this study was to examine...

  10. Anisotropic diffusion phantoms based on microcapillaries

    Science.gov (United States)

    Vellmer, Sebastian; Edelhoff, Daniel; Suter, Dieter; Maximov, Ivan I.

    2017-06-01

    Diffusion MRI is an efficient and widely used technique for the investigation of tissue structure and organisation in vivo. Multiple phenomenological and biophysical diffusion models are intensively exploited for the analysis of the diffusion experiments. However, the verification of the applied diffusion models remains challenging. In order to provide a ;gold standard; and to assess the accuracy of the derived parameters and the limitations of the diffusion models, anisotropic diffusion phantoms with well known architecture are demanded. In the present work we built four anisotropic diffusion phantoms consisting of hollow microcapillaries with very small inner diameters of 5, 10 and 20 μ m and outer diameters of 90 and 150 μ m. For testing the suitability of these phantoms, we performed diffusion measurements on all of them and evaluated the resulting data with a set of popular diffusion models, such as diffusion tensor and diffusion kurtosis imaging, a two compartment model with intra- and extra-capillary water spaces using bi-exponential fitting, and time-dependent diffusion coefficients in Mitra's limit. The perspectives and limitations of these diffusion phantoms are presented and discussed.

  11. New eye phantom for ophthalmic surgery

    Science.gov (United States)

    Fogli, Gessica; Orsi, Gianni; De Maria, Carmelo; Montemurro, Francesca; Palla, Michele; Rizzo, Stanislao; Vozzi, Giovanni

    2014-06-01

    In this work, we designed and realized a new phantom able to mimic the principal mechanical, rheological, and physical cues of the human eye and that can be used as a common benchmark to validate new surgical procedures, innovative vitrectomes, and as a training system for surgeons. This phantom, in particular its synthetic humor vitreous, had the aim of reproducing diffusion properties of the natural eye and can be used as a system to evaluate the pharmacokinetics of drugs and optimization of their dose, limiting animal experiments. The eye phantom was built layer-by-layer starting from the sclera up to the retina, using low cost and easy to process polymers. The validation of the phantom was carried out by mechanical characterization of each layer, by diffusion test with commercial drugs into a purposely developed apparatus, and finally by a team of ophthalmic surgeons. Experiments demonstrated that polycaprolactone, polydimethylsiloxane, and gelatin, properly prepared, are the best materials to mimic the mechanical properties of sclera, choroid, and retina, respectively. A polyvinyl alcohol-gelatin polymeric system is the best for mimicking the viscosity of the human humor vitreous, even if the bevacizumab half-life is lower than in the human eye.

  12. A Rat Body Phantom for Radiation Analysis

    Science.gov (United States)

    Qualls, Garry D.; Clowdsley, Martha S.; Slaba, Tony C.; Walker, Steven A.

    2010-01-01

    To reduce the uncertainties associated with estimating the biological effects of ionizing radiation in tissue, researchers rely on laboratory experiments in which mono-energetic, single specie beams are applied to cell cultures, insects, and small animals. To estimate the radiation effects on astronauts in deep space or low Earth orbit, who are exposed to mixed field broad spectrum radiation, these experimental results are extrapolated and combined with other data to produce radiation quality factors, radiation weighting factors, and other risk related quantities for humans. One way to reduce the uncertainty associated with such extrapolations is to utilize analysis tools that are applicable to both laboratory and space environments. The use of physical and computational body phantoms to predict radiation exposure and its effects is well established and a wide range of human and non-human phantoms are in use today. In this paper, a computational rat phantom is presented, as well as a description of the process through which that phantom has been coupled to existing radiation analysis tools. Sample results are presented for two space radiation environments.

  13. Cortical Depression and Potentiation: Basic Mechanisms for Phantom Pain

    OpenAIRE

    Zhuo, Min

    2012-01-01

    People experience the feeling of the missing body part long after it has been removed after amputation are known as phantom limb sensations. These sensations can be painful, sometimes becoming chronic and lasting for several years (or called phantom pain). Medical treatment for these individuals is limited. Recent neurobiological investigations of brain plasticity after amputation have revealed new insights into the changes in the brain that may cause phantom limb sensations and phantom pain....

  14. Atypical supernumerary phantom limb and phantom limb pain in two patients with pontine hemorrhage.

    Science.gov (United States)

    Yoo, Seung Don; Kim, Dong Hwan; Jeong, Yong Seol; Chon, Jinmann; Bark, Jihea

    2011-06-01

    Phantom limbs are usually observed after amputation of extremities. In patients after a stroke, a similar but rarely occurring phenomenon consisting of the patient experiencing the presence of an additional limb has been described. This phenomenon, generally called supernumerary phantom limb (SPL), may be caused by lesions in the right or left cerebral hemisphere, but has been predominantly reported in patients who have had a right hemispheric stroke. We report two cases of atypical SPL and phantom limb pain (PLP) after pontine hemorrhage. The patients were treated conservatively and their symptoms lasted more than 1 month. This is the first report of SPLs after left pontine hemorrhage, and phantom perception and pain lasted longer than those in previously observed cases. Our results indicate that SPL may be more common than reported; therefore, thorough examinations are essential for the care of stroke patients.

  15. Computerized scheme for evaluating mammographic phantom images.

    Science.gov (United States)

    Asahara, Masaki; Kodera, Yoshie

    2012-03-01

    The authors developed a computer algorithm to automatically evaluate images of the American College of Radiology (ACR) mammography accreditation phantom. The developed algorithm consist of the edge detection of wax insert, nonuniformity correction of background, and correction for magnification and also calculate the cross-correlation coefficient by image matching technique. The algorithm additionally evaluates target shape for fibers, target contrast for speck groups, and target circularity for masses. To obtain an ideal template image without noise and spatial resolution loss, the wax insert containing the embedded test pattern was extracted from the phantom and radiographed. Two template images and ten test phantom images were prepared for this study. The results of evaluation using the algorithm outputs were compared with the averaged results of observer studies by six skilled observers. In comparing the results from the algorithm outputs with the results of observers, the authors found that the computer outputs were well correlated with the evaluations by observers, and they indicate the quality of the phantom image. The correlation coefficients between results of observer studies and two outputs of computer algorithm, i.e., the cross-correlation coefficient by template matching and indices of target shape for fibers, were 0.89 (95% confidence interval, 0.82-0.93; hereinafter the same) and 0.85 (0.76-0.91). The correlation coefficients between observer's results and two outputs: the cross-correlation coefficient and indices of target contrast for speck groups, were 0.83 (0.79-0.86) and 0.85 (0.81-0.88) and between observer's results and two outputs: the cross-correlation coefficient and indices of target circularity for masses, were 0.90 (0.84-0.94) and 0.87 (0.77-0.92). Image evaluation using the ACR phantom is indispensable in quality control of a mammography system. The proposed algorithm is useful for quality control and image evaluation of mammography

  16. 21 CFR 892.1380 - Nuclear flood source phantom.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear flood source phantom. 892.1380 Section 892...) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1380 Nuclear flood source phantom. (a) Identification. A nuclear flood source phantom is a device that consists of a radiolucent container filled with a...

  17. 21 CFR 892.1420 - Radionuclide test pattern phantom.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Radionuclide test pattern phantom. 892.1420... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1420 Radionuclide test pattern phantom. (a) Identification. A radionuclide test pattern phantom is a device that consists of an arrangement...

  18. 21 CFR 892.1370 - Nuclear anthropomorphic phantom.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Nuclear anthropomorphic phantom. 892.1370 Section... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1370 Nuclear anthropomorphic phantom. (a) Identification. A nuclear anthropomorphic phantom is a human tissue facsimile that contains a...

  19. Revealing the invisible: the paradox of picturing a phantom limb.

    Science.gov (United States)

    Schott, G D

    2014-03-01

    Illustrations of phantom limbs are intriguing as they depict an invisible perception. But such illustrations are also important: they provide a form of objectivity to phenomena, which particularly in the past, have often stretched credulity. Acknowledging the paradox of using images to reveal an absent though sensate body part, depictions of phantom limbs are discussed from the neurological perspective, starting with medieval pictures that showed the miraculous restoration of limbs, and which possibly represented pictorial metaphors for a phantom limb. Centuries later, phantom limbs-whether resulting from amputation or deafferentation-became illustrated, and some reasons for their illustration are considered. Although often depicted by others, the most precise and perhaps revealing illustrations of these phantoms have been those made when patients guide the artist, or draw the phantom themselves. In the case of phantom pains, the painful component too is sometimes illustrated, again, as with the miraculous, in metaphorical terms. More recently, depictions of phantoms have also been revealing in studies of some underlying mechanisms of phantom phenomena, notably in demonstrating novel patterns of referred sensations after amputation and attributable to cortical plasticity. Mention is made of photographs of phantom hands visualized using a mirror box, such visualization recalling full circle the miraculous restoration of limbs pictured in the past. The nature of the outline of the phantom is included in a discussion of demarcation of an invisible body part, before concluding that images of phantom limbs provide an invaluable background to understanding and studying these remarkable sensory phenomena.

  20. Collinear technology for a holographic versatile disk

    Science.gov (United States)

    Horimai, Hideyoshi; Tan, Xiaodi

    2006-02-01

    A novel reading and writing technology for a holographic versatile disk (HVD) system called collinear technology is developed. With this method a two-dimensional data page can be recorded as volumetric holograms generated by a reference beam and a signal beam that are bundled on the same axis and that are irradiated on the recording medium through a single objective lens. The multiplex recording and reconstruction process is demonstrated, and it is shown that the optical configuration and the dichroic medium disk structure are suitable for a compact system. With the HVD's special structure, the system can use a servo to focus, track, and locate the reading and writing addresses. A unique selectable-capacity recording format of a HVD and its standardization activity are also introduced. This method will enable us to construct a small HVD system with CD and DVD upper compatibilities.

  1. Survey of phantom limb pain, phantom sensation and stump pain in Cambodian and New Zealand amputees.

    Science.gov (United States)

    Byrne, Kelly Patrick Anthony

    2011-05-01

    The primary objective of this study is to compare the prevalence of phantom limb pain in New Zealand and Cambodian amputees and to assess the demographics of a sample of amputees from these two countries. All participants were interviewed using a 12-question survey that covered demographic data and reason for amputation and assessed the presence of phantom limb sensation, phantom limb pain, and stump pain. Amputees attending an artificial limb center in Cambodia were approached and interviewed in person. New Zealand amputees attending the Waikato artificial limb center were randomly selected and interviewed by phone. There was no statistically significant difference in phantom limb sensation, phantom limb pain, or stump pain between the two groups. There was a much higher unemployment rate in the Cambodian amputees. There were no other statistically significant differences between the groups Despite very different environments, there was no difference in the phantom limb pain between the groups. One possible explanation is that the severity of neurological injury associated with amputation overrides all the other risk factors that influence the development of other chronic pain syndromes. Wiley Periodicals, Inc.

  2. Motor control over the phantom limb in above-elbow amputees and its relationship with phantom limb pain.

    Science.gov (United States)

    Gagné, M; Reilly, K T; Hétu, S; Mercier, C

    2009-08-04

    Recent evidence shows that the primary motor cortex continues to send motor commands when amputees execute phantom movements. These commands are retargeted toward the remaining stump muscles as a result of motor system reorganization. As amputation-induced reorganization in the primary motor cortex has been associated with phantom limb pain we hypothesized that the motor control of the phantom limb would differ between amputees with and without phantom limb pain. Eight above-elbow amputees with or without pain were included in the study. They were asked to produce cyclic movements with their phantom limb (hand, wrist, and elbow movements) while simultaneously reproducing the same movement with the intact limb. The time needed to complete a movement cycle and its amplitude were derived from the kinematics of the intact limb. Electromyographic (EMG) activity from different stump muscles and from the homologous muscles on the intact side was recorded. Different EMG patterns were recorded in the stump muscles depending on the movement produced, showing that different phantom movements are associated with distinct motor commands. Phantom limb pain was associated with some aspects of phantom limb motor control. The time needed to complete a full cycle of a phantom movement was systematically shorter in subjects without phantom limb pain. Also, the amount of EMG modulation recorded in a stump muscle during a phantom hand movement was positively correlated with the intensity of phantom limb pain. Since phantom hand movement-related EMG patterns in above-elbow stump muscles can be considered as a marker of motor system reorganization, this result indirectly supports the hypothesis that amputation-induced plasticity is associated with phantom limb pain severity. The discordance between the (amputated) hand motor command and the feedback from above-elbow muscles might partially explain why subjects exhibiting large EMG modulation during phantom hand movement have more phantom

  3. Phantom Remodeling Effect of Dorsal Root Entry Zone Lesioning in Phantom Limb Pain Caused by Brachial Plexus Avulsion.

    Science.gov (United States)

    Son, Byung-Chul; Ha, Sang-Woo

    2015-01-01

    Dorsal root entry zone (DREZ) lesioning has been reported to be effective for phantom limb pain caused by brachial plexus avulsion pain. Most reports on DREZ lesioning for brachial plexus avulsion pain have focused on the results of pain relief without a detailed description of phantom sensations following DREZ lesioning. Two patients (1 with amputation and the other nonamputated) with chronic intractable phantom limb pain caused by brachial plexus avulsion underwent DREZ lesioning on the avulsed segments of the cervical spinal cords. Changes of the phantom limb were observed. Immediately following DREZ lesioning, the phantom limb pain disappeared in the amputee, the phantom arm was shortened and the phantom hand disappeared. The other patient with the nonamputated arm reported an immediate 50% reduction in the size of the phantom hand, and pain relief was up to 70% of the preoperative phantom limb pain. There was no further change in the phantom arm and hand during the follow-up of 1.5-2 years. The phantom arms and hands showed a prompt shortening and reduction in size, rather than a disappearance, following successful DREZ lesioning in patients with chronic phantom limb pain caused by brachial plexus avulsion. © 2015 S. Karger AG, Basel.

  4. Fabrication of Two Flow Phantoms for Doppler Ultrasound Imaging.

    Science.gov (United States)

    Zhou, Xiaowei; Kenwright, David A; Wang, Shiying; Hossack, John A; Hoskins, Peter R

    2017-01-01

    Flow phantoms are widely used in studies associated with Doppler ultrasound measurements, acting as an effective experimental validation system in cardiovascular-related research and in new algorithm/instrumentation development. The development of materials that match the acoustic and mechanical properties of the vascular system is of great interest while designing flow phantoms. Although recipes that meet the flow phantom standard defined by the International Electrotechnical Commission 61685 are already available in the literature, the standard procedure for material preparations and phantom fabrications has not been well established. In this paper, two types of flow phantoms, with and without blood vessel mimic, are described in detail in terms of the material preparation and phantom fabrication. The phantom materials chosen for the two phantoms are from published phantom studies, and their physical properties have been investigated previously. Both the flow phantoms have been scanned by ultrasound scanners and images from different modes are presented. These phantoms may be used in the validation and characterization of Doppler ultrasound measurements in blood vessels with a diameter above 1 mm.

  5. Pipe Phantoms With Applications in Molecular Imaging and System Characterization.

    Science.gov (United States)

    Wang, Shiying; Herbst, Elizabeth B; Pye, Stephen D; Moran, Carmel M; Hossack, John A

    2017-01-01

    Pipe (vessel) phantoms mimicking human tissue and blood flow are widely used for cardiovascular related research in medical ultrasound. Pipe phantom studies require the development of materials and liquids that match the acoustic properties of soft tissue, blood vessel wall, and blood. Over recent years, pipe phantoms have been developed to mimic the molecular properties of the simulated blood vessels. In this paper, the design, construction, and functionalization of pipe phantoms are introduced and validated for applications in molecular imaging and ultrasound imaging system characterization. There are three major types of pipe phantoms introduced: 1) a gelatin-based pipe phantom; 2) a polydimethylsiloxane-based pipe phantom; and 3) the "Edinburgh pipe phantom." These phantoms may be used in the validation and assessment of the dynamics of microbubble-based contrast agents and, in the case of a small diameter tube phantom, for assessing imaging system spatial resolution/contrast performance. The materials and procedures required to address each of the phantoms are described.

  6. Toxicology Analysis of Tissue-Mimicking Phantom Made From Gelatin

    Science.gov (United States)

    Dolbashid, A. S.; Hamzah, N.; Zaman, W. S. W. K.; Mokhtar, M. S.

    2017-06-01

    Skin phantom mimics the biological skin tissues as it have the ability to respond to changes in its environment. The development of tissue-mimicking phantom could contributes towards the reduce usage of animal in cosmetics and pharmacokinetics. In this study, the skin phantoms made from gelatin were tested with four different commonly available cosmetic products to determine the toxicity of each substance. The four substances used were; mercury-based whitening face cream, carcinogenic liquid make-up foundation, paraben-based acne cleanser, and organic lip balm. Toxicity test were performed on all of the phantoms. For toxicity testing, topographical and electrophysiological changes of the phantoms were evaluated. The ability of each respective phantom to react with mild toxic substances and its electrical resistance were analysed in to determine the toxicity of all the phantom models. Four-electrode method along with custom made electrical impedance analyser was used to differentiate electrical resistance between intoxicated phantom and non-intoxicated phantom in this study. Electrical resistance values obtained from the phantom models were significantly higher than the control group. The result obtained suggests the phantom as a promising candidate to be used as alternative for toxicology testing in the future.

  7. Usefulness of milnacipran in treating phantom limb pain.

    Science.gov (United States)

    Nagoshi, Yasuhide; Watanabe, Akira; Inoue, Saiko; Kuroda, Tomoki; Nakamura, Mitsuo; Matsumoto, Yoshitake; Fukui, Kenji

    2012-01-01

    Amputation of an extremity often results in the sensation of a "phantom limb" where the patient feels that the limb that has been amputated is still present. This is frequently accompanied by "phantom limb pain". We report here the use of milnacipran, a serotonin and norepinephrine reuptake inhibitor, to treat phantom limb pain after amputation of injured or diseased limbs in three patients. The severity of phantom pain before and during treatment was quantified using a visual analog scale. In one case, phantom limb pain responded partially to treatment with high doses of paroxetine, and then replacement with milnacipran further improved the pain relief and long-term full pain relief was achieved. In the two other cases, milnacipran was used as first-line treatment and phantom limb pain responded rapidly. These results suggest that milnacipran administration may be useful in phantom limb pain, possibly as a first-line treatment.

  8. Phantom limb pain after lower limb trauma: origins and treatments.

    Science.gov (United States)

    Foell, Jens; Bekrater-Bodmann, Robin; Flor, Herta; Cole, Jonathan

    2011-12-01

    Phantom sensations, that is, sensations perceived in a body part that has been lost, are a common consequence of accidental or clinical extremity amputations. Most amputation patients report a continuing presence of the limb, with some describing additional sensations such as numbness, tickling, or cramping of the phantom limb. The type, frequency, and stability of these phantom sensations can vary immensely. The phenomenon of painful phantom sensations, that is, phantom limb pain, presents a challenge for practitioners and researchers and is often detrimental to the patient's quality of life. In addition to the use of conventional therapies for chronic pain disorders, recent years have seen the development of novel treatments for phantom limb pain, based on an increasing body of research on neurophysiological changes after amputation. This article describes the current state of research in regard to the demographics, causal factors, and treatments of phantom limb pain.

  9. Usefulness of milnacipran in treating phantom limb pain

    Science.gov (United States)

    Nagoshi, Yasuhide; Watanabe, Akira; Inoue, Saiko; Kuroda, Tomoki; Nakamura, Mitsuo; Matsumoto, Yoshitake; Fukui, Kenji

    2012-01-01

    Background Amputation of an extremity often results in the sensation of a “phantom limb” where the patient feels that the limb that has been amputated is still present. This is frequently accompanied by “phantom limb pain”. We report here the use of milnacipran, a serotonin and norepinephrine reuptake inhibitor, to treat phantom limb pain after amputation of injured or diseased limbs in three patients. Methods and results The severity of phantom pain before and during treatment was quantified using a visual analog scale. In one case, phantom limb pain responded partially to treatment with high doses of paroxetine, and then replacement with milnacipran further improved the pain relief and long-term full pain relief was achieved. In the two other cases, milnacipran was used as first-line treatment and phantom limb pain responded rapidly. Conclusion These results suggest that milnacipran administration may be useful in phantom limb pain, possibly as a first-line treatment. PMID:23185119

  10. A novel breast software phantom for biomechanical modeling of elastography.

    Science.gov (United States)

    Bhatti, Syeda Naema; Sridhar-Keralapura, Mallika

    2012-04-01

    In developing breast imaging technologies, testing is done with phantoms. Physical phantoms are normally used but their size, shape, composition, and detail cannot be modified readily. These difficulties can be avoided by creating a software breast phantom. Researchers have created software breast phantoms using geometric and/or mathematical methods for applications like image fusion. The authors report a 3D software breast phantom that was built using a mechanical design tool, to investigate the biomechanics of elastography using finite element modeling (FEM). The authors propose this phantom as an intermediate assessment tool for elastography simulation; for use after testing with commonly used phantoms and before clinical testing. The authors design the phantom to be flexible in both, the breast geometry and biomechanical parameters, to make it a useful tool for elastography simulation. The authors develop the 3D software phantom using a mechanical design tool based on illustrations of normal breast anatomy. The software phantom does not use geometric primitives or imaging data. The authors discuss how to create this phantom and how to modify it. The authors demonstrate a typical elastography experiment of applying a static stress to the top surface of the breast just above a simulated tumor and calculate normal strains in 3D and in 2D with plane strain approximations with linear solvers. In particular, they investigate contrast transfer efficiency (CTE) by designing a parametric study based on location, shape, and stiffness of simulated tumors. The authors also compare their findings to a commonly used elastography phantom. The 3D breast software phantom is flexible in shape, size, and location of tumors, glandular to fatty content, and the ductal structure. Residual modulus, maps, and profiles, served as a guide to optimize meshing of this geometrically nonlinear phantom for biomechanical modeling of elastography. At best, low residues (around 1-5 KPa) were

  11. Optical phantoms with adjustable subdiffusive scattering parameters

    Science.gov (United States)

    Krauter, Philipp; Nothelfer, Steffen; Bodenschatz, Nico; Simon, Emanuel; Stocker, Sabrina; Foschum, Florian; Kienle, Alwin

    2015-10-01

    A new epoxy-resin-based optical phantom system with adjustable subdiffusive scattering parameters is presented along with measurements of the intrinsic absorption, scattering, fluorescence, and refractive index of the matrix material. Both an aluminium oxide powder and a titanium dioxide dispersion were used as scattering agents and we present measurements of their scattering and reduced scattering coefficients. A method is theoretically described for a mixture of both scattering agents to obtain continuously adjustable anisotropy values g between 0.65 and 0.9 and values of the phase function parameter γ in the range of 1.4 to 2.2. Furthermore, we show absorption spectra for a set of pigments that can be added to achieve particular absorption characteristics. By additional analysis of the aging, a fully characterized phantom system is obtained with the novelty of g and γ parameter adjustment.

  12. Phantom Space-times in Fake Supergravity

    OpenAIRE

    Taam, Maryam Bu; Sabra, Wafic A.

    2015-01-01

    We discuss phantom metrics admitting Killing spinors in fake N=2 , D=4 supergravity coupled to vector multiplets. The Abelian U(1) gauge fields in the fake theory have kinetic terms with the wrong sign. We solve the Killing spinor equations for the standard and fake theories in a unified fashion by introducing a parameter which distinguishes between the two theories. The solutions found are fully determined in terms of algebraic conditions, the so-called stabilisation equations, in which the ...

  13. Freehand ultrasound calibration: phantom versus tracked pointer

    Science.gov (United States)

    Welch, Mattea; Andrea, Jennifer; Ungi, Tamas; Fichtinger, Gabor

    2013-03-01

    PURPOSE: Ultrasound-guided tracked navigation requires spatial calibration between the ultrasound beam and the tracker. We examined the reproducibility and accuracy of two popular open source calibration methods1 with a handheld linear ultrasound transducer. METHODS: A total of 10 calibrations were performed using (1) a double N-wire phantom with automatic image segmentation and registration; (2) and registration of landmark points collected with a tracked pointer. Reproducibility and accuracy were characterized by comparing the resulting transformation matrices, and by comparing ground truth landmark points. RESULTS: Transformation matrices calculated with an N-wire phantom showed a variance of X: 0.02 mm (in the direction of sound propagation), Y: 0.03 mm (in the direction of transducer elements) and Z: 0.21 mm (in the elevation direction). Transformation matrices obtained with tracked pointer showed a variance of X: 0.1 mm, Y: 0.10 mm and Z: 0.43 mm. Calibration accuracy was tested with ground truth cross wire points. The N-wire phantom provided a calibration with a distance from ground truth of X: 2.44 +/- 1.44 mm, Y: 1.21 +/- 0.88 mm, and Z: 1.12 +/- 0.82 mm. Tracked pointer calibration had a distance from the ground truth of X: 0.23 +/- 0.16 mm, Y: 0.62 +/- 0.31 mm, and Z: 0.45 +/- 0.33 mm. Distance from ground truth was significantly less (ptracked pointer method in all directions. CONCLUSION: Calibration using a tracked pointer had a slightly greater variance; however it showed better accuracy over calibrations calculated with N-wire phantoms.

  14. Automatic Synthesis of Anthropomorphic Pulmonary CT Phantoms

    Science.gov (United States)

    Jimenez-Carretero, Daniel; San Jose Estepar, Raul; Diaz Cacio, Mario; Ledesma-Carbayo, Maria J.

    2016-01-01

    The great density and structural complexity of pulmonary vessels and airways impose limitations on the generation of accurate reference standards, which are critical in training and in the validation of image processing methods for features such as pulmonary vessel segmentation or artery–vein (AV) separations. The design of synthetic computed tomography (CT) images of the lung could overcome these difficulties by providing a database of pseudorealistic cases in a constrained and controlled scenario where each part of the image is differentiated unequivocally. This work demonstrates a complete framework to generate computational anthropomorphic CT phantoms of the human lung automatically. Starting from biological and image-based knowledge about the topology and relationships between structures, the system is able to generate synthetic pulmonary arteries, veins, and airways using iterative growth methods that can be merged into a final simulated lung with realistic features. A dataset of 24 labeled anthropomorphic pulmonary CT phantoms were synthesized with the proposed system. Visual examination and quantitative measurements of intensity distributions, dispersion of structures and relationships between pulmonary air and blood flow systems show good correspondence between real and synthetic lungs (p > 0.05 with low Cohen’s d effect size and AUC values), supporting the potentiality of the tool and the usefulness of the generated phantoms in the biomedical image processing field. PMID:26731653

  15. Materials for phantoms for terahertz pulsed imaging

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Gillian C [Academic Unit of Medical Physics, University of Leeds, Wellcome Wing, Leeds General Infirmary, Great George Street, Leeds, LS1 3EX (United Kingdom); Berry, Elizabeth [Academic Unit of Medical Physics, University of Leeds, Wellcome Wing, Leeds General Infirmary, Great George Street, Leeds, LS1 3EX (United Kingdom); Smye, Stephen W [Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, St James University Hospital, Leeds, LS9 7TF (United Kingdom); Brettle, David S [Department of Medical Physics and Engineering, Leeds Teaching Hospitals NHS Trust, St James University Hospital, Leeds, LS9 7TF (United Kingdom)

    2004-11-07

    Phantoms are commonly used in medical imaging for quality assurance, calibration, research and teaching. They may include test patterns or simulations of organs, but in either case a tissue substitute medium is an important component of the phantom. The aim of this work was to identify materials suitable for use as tissue substitutes for the relatively new medical imaging modality terahertz pulsed imaging. Samples of different concentrations of the candidate materials TX151 and napthol green dye were prepared, and measurements made of the frequency-dependent absorption coefficient (0.5 to 1.5 THz) and refractive index (0.5 to 1.0 THz). These results were compared qualitatively with measurements made in a similar way on samples of excised human tissue (skin, adipose tissue and striated muscle). Both materials would be suitable for phantoms where the dominant mechanism to be simulated is absorption ({approx}100 cm{sup -1} at 1 THz) and where simulation of the strength of reflections from boundaries is not important; for example, test patterns for spatial resolution measurements. Only TX151 had a frequency-dependent refractive index close to that of tissue, and could therefore be used to simulate the layered structure of skin, the complexity of microvasculature or to investigate frequency-dependent interference effects that have been noted in terahertz images. (note)

  16. Automatic Synthesis of Anthropomorphic Pulmonary CT Phantoms.

    Directory of Open Access Journals (Sweden)

    Daniel Jimenez-Carretero

    Full Text Available The great density and structural complexity of pulmonary vessels and airways impose limitations on the generation of accurate reference standards, which are critical in training and in the validation of image processing methods for features such as pulmonary vessel segmentation or artery-vein (AV separations. The design of synthetic computed tomography (CT images of the lung could overcome these difficulties by providing a database of pseudorealistic cases in a constrained and controlled scenario where each part of the image is differentiated unequivocally. This work demonstrates a complete framework to generate computational anthropomorphic CT phantoms of the human lung automatically. Starting from biological and image-based knowledge about the topology and relationships between structures, the system is able to generate synthetic pulmonary arteries, veins, and airways using iterative growth methods that can be merged into a final simulated lung with realistic features. A dataset of 24 labeled anthropomorphic pulmonary CT phantoms were synthesized with the proposed system. Visual examination and quantitative measurements of intensity distributions, dispersion of structures and relationships between pulmonary air and blood flow systems show good correspondence between real and synthetic lungs (p > 0.05 with low Cohen's d effect size and AUC values, supporting the potentiality of the tool and the usefulness of the generated phantoms in the biomedical image processing field.

  17. [Somatognosis, body schema and the phenomena of somatic and visceral phantoms and phantom pain].

    Science.gov (United States)

    Tichý, J

    2003-01-01

    The body scheme is a complex of memory patterns secured in the structures of the brain, where the parietal lobes play the most important role. Basic principles are given by the genetic programming of the structure and function along with the synthesis of information brought by means of sensory activity. The unitary perception of the body scheme is a dynamic image, enabling conscious and unconscious representation of our body, its parts, their functions, position, shape and/or movements. The recognition of the body scheme in humans is named somatognosia. Disorders of somatognosia include visceral and somatic phantom, phantom pain and other disorders related to the capability of communication by means of language: autotopoagnosia, hemiasomatognosia, pain asymboly, anosognosia of hemiplegia, anosognosia of blindness, deafness, neglect and other defects appearing at the neurologist's and psychiatrist's borderline of interest. Interest in the visceral phantom is usually much smaller than that in the phantom limb. The aim of this paper was to draw the to phantom phenomena in patients following rectum amputation and colostomy. A survey of contemporary knowledge about the body scheme and its disorders, cortical plasticity and the problem of cortical maladaptation are presented.

  18. A study of partial volume effect on SPECT imaging using myocardial phantom. With HCM (ASH) model myocardial phantom

    Energy Technology Data Exchange (ETDEWEB)

    Onoguchi, Masahisa [Kanazawa Univ. (Japan). School of Medicine

    1997-05-01

    In order to evaluate simultaneously both myocardial perfusion and regional wall motion using ECG-gated myocardial SPECT imaging, correction for the partial volume effect (PVE) should be performed. For the quantitative analysis of myocardial SPECT imaging in patients with hypertrophic cardiomyopathy (HCM), we formed a new phantom simulating HCM with various septal wall thicknesses and estimated PVE using the recovery coefficient (RC). The value of RC in all phantoms increased with increasing thickness of the septal wall reaching a plateau at 25 mm for the cylindrical phantom and 25 mm for the Ep-phantom. Compared with the RC value, the PMMA-phantom had little influence on PVE. Therefore, our results suggested that the count in the septal wall could be underestimated if PVE was corrected by the value obtained for the cylindrical phantom. In conclusion, our new phantom simulating HCM was useful in assessing PVE in the hypertrophic septal wall. (author)

  19. Development of versatile multiaperture negative ion sources

    Science.gov (United States)

    Cavenago, M.; Serianni, G.; Antoni, V.; Bigi, M.; De Muri, M.; Pasqualotto, R.; Recchia, M.; Veltri, P.; Agostinetti, P.; Barbisan, M.; Baseggio, L.; Cervaro, V.; Cazzador, M.; Degli Agostini, F.; Franchin, L.; Kulevoy, T.; Laterza, B.; Mimo, A.; Minarello, A.; Petrenko, S.; Ravarotto, D.; Rossetto, F.; Sattin, M.; Zaniol, B.; Zucchetti, S.

    2015-04-01

    Enhancement of negative ion sources for production of large ion beams is a very active research field nowadays, driven from demand of plasma heating in nuclear fusion devices and accelerator applications. As a versatile test bench, the ion source NIO1 (Negative Ion Optimization 1) is being commissioned by Consorzio RFX and INFN. The nominal beam current of 135 mA at -60 kV is divided into 9 beamlets, with multiaperture extraction electrodes. The plasma is sustained by a 2 MHz radiofrequency power supply, with a standard matching box. A High Voltage Deck (HVD) placed inside the lead shielding surrounding NIO1 contains the radiofrequency generator, the gas control, electronics and power supplies for the ion source. An autonomous closed circuit water cooling system was installed for the whole system, with a branch towards the HVD, using carefully optimized helical tubing. Insulation transformer is installed in a nearby box. Tests of several magnetic configurations can be performed. Status of experiments, measured spectra and plasma luminosity are described. Upgrades of magnetic filter, beam calorimeter and extraction grid and related theoretical issues are reviewed.

  20. Versatility of hydrocarbon production in cyanobacteria.

    Science.gov (United States)

    Xie, Min; Wang, Weihua; Zhang, Weiwen; Chen, Lei; Lu, Xuefeng

    2017-02-01

    Cyanobacteria are photosynthetic microorganisms using solar energy, H2O, and CO2 as the primary inputs. Compared to plants and eukaryotic microalgae, cyanobacteria are easier to be genetically engineered and possess higher growth rate. Extensive genomic information and well-established genetic platform make cyanobacteria good candidates to build efficient biosynthetic pathways for biofuels and chemicals by genetic engineering. Hydrocarbons are a family of compounds consisting entirely of hydrogen and carbon. Structural diversity of the hydrocarbon family is enabled by variation in chain length, degree of saturation, and rearrangements of the carbon skeleton. The diversified hydrocarbons can be used as valuable chemicals in the field of food, fuels, pharmaceuticals, nutrition, and cosmetics. Hydrocarbon biosynthesis is ubiquitous in bacteria, yeasts, fungi, plants, and insects. A wide variety of pathways for the hydrocarbon biosynthesis have been identified in recent years. Cyanobacteria may be superior chassis for hydrocabon production in a photosynthetic manner. A diversity of hydrocarbons including ethylene, alkanes, alkenes, and terpenes can be produced by cyanobacteria. Metabolic engineering and synthetic biology strategies can be employed to improve hydrocarbon production in cyanobacteria. This review mainly summarizes versatility and perspectives of hydrocarbon production in cyanobacteria.

  1. Plasmonic Biofoam: A Versatile Optically Active Material.

    Science.gov (United States)

    Tian, Limei; Luan, Jingyi; Liu, Keng-Ku; Jiang, Qisheng; Tadepalli, Sirimuvva; Gupta, Maneesh K; Naik, Rajesh R; Singamaneni, Srikanth

    2016-01-13

    Owing to their ability to confine and manipulate light at the nanoscale, plasmonic nanostructures are highly attractive for a broad range of applications. While tremendous progress has been made in the synthesis of size- and shape-controlled plasmonic nanostructures, their integration with other materials and application in solid-state is primarily through their assembly on rigid two-dimensional (2D) substrates, which limits the plasmonically active space to a few nanometers above the substrate. In this work, we demonstrate a simple method to create plasmonically active three-dimensional biofoams by integrating plasmonic nanostructures with highly porous biomaterial aerogels. We demonstrate that plasmonic biofoam is a versatile optically active platform that can be harnessed for numerous applications including (i) ultrasensitive chemical detection using surface-enhanced Raman scattering; (ii) highly efficient energy harvesting and steam generation through plasmonic photothermal heating; and (iii) optical control of enzymatic activity by triggered release of biomolecules encapsulated within the aerogel. Our results demonstrate that 3D plasmonic biofoam exhibits significantly higher sensing, photothermal, and loading efficiency compared to conventional 2D counterparts. The design principles and processing methodology of plasmonic aerogels demonstrated here can be broadly applied in the fabrication of other functional foams.

  2. Computerized scheme for evaluating mammographic phantom images

    Energy Technology Data Exchange (ETDEWEB)

    Asahara, Masaki; Kodera, Yoshie [Graduate School of Medical Sciences, Nagoya University, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan) and Department of Radiology, Kagawa University Hospital, 1750-1 Ikenobe, Miki-cho, Kita-gun, Kagawa 761-0793 (Japan); Graduate School of Medical Sciences, Nagoya University, 1-1-20 Daiko-minami, Higashi-ku, Nagoya, Aichi 461-8673 (Japan)

    2012-03-15

    Purpose: The authors developed a computer algorithm to automatically evaluate images of the American College of Radiology (ACR) mammography accreditation phantom. Methods: The developed algorithm consist of the edge detection of wax insert, nonuniformity correction of background, and correction for magnification and also calculate the cross-correlation coefficient by image matching technique. The algorithm additionally evaluates target shape for fibers, target contrast for speck groups, and target circularity for masses. To obtain an ideal template image without noise and spatial resolution loss, the wax insert containing the embedded test pattern was extracted from the phantom and radiographed. Two template images and ten test phantom images were prepared for this study. The results of evaluation using the algorithm outputs were compared with the averaged results of observer studies by six skilled observers. Results: In comparing the results from the algorithm outputs with the results of observers, the authors found that the computer outputs were well correlated with the evaluations by observers, and they indicate the quality of the phantom image. The correlation coefficients between results of observer studies and two outputs of computer algorithm, i.e., the cross-correlation coefficient by template matching and indices of target shape for fibers, were 0.89 (95% confidence interval, 0.82-0.93; hereinafter the same) and 0.85 (0.76-0.91). The correlation coefficients between observer's results and two outputs: the cross-correlation coefficient and indices of target contrast for speck groups, were 0.83 (0.79-0.86) and 0.85 (0.81-0.88) and between observer's results and two outputs: the cross-correlation coefficient and indices of target circularity for masses, were 0.90 (0.84-0.94) and 0.87 (0.77-0.92). Conclusions: Image evaluation using the ACR phantom is indispensable in quality control of a mammography system. The proposed algorithm is useful for

  3. Brachial plexus block in phantom limb pain: a case report.

    Science.gov (United States)

    Preissler, Sandra; Dietrich, Caroline; Meissner, Winfried; Huonker, Ralph; Hofmann, Gunther O; Miltner, Wolfgang H R; Weiss, Thomas

    2011-11-01

    The purpose of this case report is twofold: first, to present evidence of long-lasting relief in a patient suffering from phantom limb pain after pharmacologically blocking his plexus brachialis and, second, to replicate results from a previous study focusing on cortical reorganization and phantom limb pain. Before regional anesthesia, the patient suffered from a phantom hand that cramped and was immovable. We performed a diagnostic axillary blockade of the brachial plexus to differentiate peripheral from more central contributions to phantom limb pain. During blockade of the brachial plexus, the patient reported a reduction of phantom limb pain for the first time following years of suffering and a complete loss of cramping together with muscle relaxation of the phantom hand. Additionally, we found cortical reorganization in the primary somatosensory cortex (re-reorganization). Strikingly, the relaxed phantom limb together with the reduction of phantom limb pain remained preserved even 6 months after blockade of the brachial plexus. A single temporary blockade of the brachial plexus may relieve phantom limb pain and unpleasant phantom feelings (cramping) for an extended period. Wiley Periodicals, Inc.

  4. A realistic pelvic phantom for electrical impedance measurement.

    Science.gov (United States)

    Dunne, Eoghan; McGinley, Brian; O'Halloran, Martin; Porter, Emily

    2017-12-22

    To design and fabricate an anatomically and conductively accurate phantom for electrical impedance studies of non-invasive bladder volume monitoring. Approach: A modular pelvic phantom was designed and fabricated, consisting of a mechanically and conductively stable boundary wall, a background medium, and bladder phantoms. The wall and bladders are made of conductive polyurethane. The background material is an ultrasound gel-based mixture, with conductivity matched to a weighted average of the pelvic cavity organs, bone, muscle and fat. The phantom boundary is developed using a computer tomography model of a male human pelvis. The bladder phantoms were designed to correlate with human bladder dimensions. Electrical impedance measurements of the phantom were recorded, and images produced using six different bladder phantoms and a realistic finite element model. Main results: Five different bladder volumes were successfully imaged using an empty bladder as a reference. The average conductivity index from the reconstructed images showed a strong positive correlation with the bladder phantom volumes. Significance: A conductively and anatomically accurate pelvic phantom was developed for non-invasive bladder volume monitoring using electrical impedance measurements. Several bladders were designed to correlate with actual human bladder volumes, allowing for accurate volume estimation. The conductivity of the phantom is accurate over 50-250 kHz. This phantom can allow: changeable electrode location, contact and size; multi-layer electrodes configurations; increased complexity by addition of other organ or bone phantoms; and electrode movement and deformation. Overall, the pelvic phantom enables greater scope for experimentation and system refinement as a precursor to in-man clinical studies. © 2017 Institute of Physics and Engineering in Medicine.

  5. Phantom limb pain from spinal sarcoma: a case report.

    Science.gov (United States)

    Cruz, Ernesto; Dangaria, Harsh T

    2013-07-01

    Phantom limb pain is a frequent sequela of amputation. A high prevalence of residual limb pain and back pain also exists among amputees. We present a case of a new-onset severe phantom limb pain resulting from a metastatic spinal mass in an 81-year-old patient with a history of malignant sarcoma and an old hip disarticulation amputation. The metastatic lesion, upon imaging, was found to involve the L3 vertebra and caused moderate compression of the thecal sac on the right and severe right lateral recess stenosis. After the mass was resected, the patient's phantom limb pain resolved. Our case report demonstrates that spinal metastatic pathologies may be a cause of phantom limb pain and should be included in the differential diagnosis of new-onset phantom limb pain or a change in phantom limb pain. Copyright © 2013 American Academy of Physical Medicine and Rehabilitation. Published by Elsevier Inc. All rights reserved.

  6. Development of thyroid anthropomorphic phantoms for use in nuclear medicine

    Science.gov (United States)

    Cerqueira, R. A. D.; Maia, A. F.

    2014-02-01

    The objective of this study was to develop thyroid anthropomorphic phantoms to be used in control tests of medical images in scintillation cameras. The main difference among the phantoms was the neck shape: in the first, called OSCT, it was geometrically shaped, while in the second, called OSAP, it was anthropomorphically shaped. In both phantoms, thyroid gland prototypes, which were made of acrylic and anthropomorphically shaped, were constructed to allow the simulation of a healthy thyroid and of thyroids with hyperthyroidism and hypothyroidism. Images of these thyroid anthropomorphic phantoms were obtained using iodine 131 with an activity of 8.695 MBq. The iodine 131 was chosen because it is widely used in studies of thyroid scintigraphy. The images obtained proved the effectiveness of the phantoms to simulate normal or abnormal thyroids function. These phantoms can be used in medical imaging quality control programs and, also in the training of professionals involved in the analysis of images in nuclear medicine centers.

  7. Versatile transmission ellipsometry to study linear ferrofluid magneto-optics

    NARCIS (Netherlands)

    Kooij, Ernst S.; Galca, A.C.; Poelsema, Bene

    2006-01-01

    Linear birefringence and dichroism of magnetite ferrofluids are studied simultaneously using spectroscopic ellipsometry in transmission mode. It is shown that this versatile technique enables highly accurate characterisation of magneto-optical phenomena. Magnetic field-dependent linear birefringence

  8. A versatile hardware platform for brain computer interfaces.

    Science.gov (United States)

    Garcia, Pablo A; Haberman, Marcelo; Spinelli, Enrique M

    2010-01-01

    This article presents the development of a versatile hardware platform for brain computer interfaces (BCI). The aim of this work is to produce a small, autonomous and configurable BCI platform adaptable to the user's needs.

  9. Electrospun nanofibers as versatile interfaces for efficient gene delivery

    National Research Council Canada - National Science Library

    Lee, Slgirim; Jin, Gyuhyung; Jang, Jae-Hyung

    2014-01-01

    The integration of gene delivery technologies with electrospun nanofibers is a versatile strategy to increase the potential of gene therapy as a key platform technology that can be readily utilized...

  10. Calibrating pen dosimeters with and without a phantom

    Energy Technology Data Exchange (ETDEWEB)

    Nonato, Fernanda B.C.; Cescon, Claudinei T.; Caldas, Linda V.E., E-mail: fbnonato@ipen.b, E-mail: ctcescon@ipen.b, E-mail: lcaldas@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    Thirty one direct reading dosimeters (pen dosimeters) were calibrated and tested in standard beams of gamma radiation, with and without the use of a phantom. The calibration was performed with a Co-60 source and tested with a Cs-137 source. The dose-response curves of the pen dosimeters and their calibration factors for a Co-60 source, with and without the use of a phantom were obtained. The results show the need to calibrate the pen dosimeters with a phantom. (author)

  11. Creating 3D gelatin phantoms for experimental evaluation in biomedicine

    Directory of Open Access Journals (Sweden)

    Stein Nils

    2015-09-01

    Full Text Available We describe and evaluate a setup to create gelatin phantoms by robotic 3D printing. Key aspects are the large workspace, reproducibility and resolution of the created phantoms. Given its soft tissue nature, the gelatin is kept fluid during inside the system and we present parameters for additive printing of homogeneous, solid objects. The results indicate that 3D printing of gelatin can be an alternative for quickly creating larger soft tissue phantoms without the need for casting a mold.

  12. Dynamics of coupled phantom and tachyon fields

    Energy Technology Data Exchange (ETDEWEB)

    Shahalam, M. [Zhejiang University of Technology, Institute for Advanced Physics and Mathematics, Hangzhou (China); Pathak, S.D.; Li, Shiyuan [Shandong University, School of Physics, Jinan (China); Myrzakulov, R. [Eurasian National University, Department of General and Theoretical Physics, Eurasian International Center for Theoretical Physics, Astana (Kazakhstan); Wang, Anzhong [Zhejiang University of Technology, Institute for Advanced Physics and Mathematics, Hangzhou (China); Baylor University, Department of Physics, GCAP-CASPER, Waco, TX (United States)

    2017-10-15

    In this paper, we apply the dynamical analysis to a coupled phantom field with scaling potential taking particular forms of the coupling (linear and combination of linear), and present phase space analysis. We investigate if there exists a late time accelerated scaling attractor that has the ratio of dark energy and dark matter densities of the order one. We observe that the scrutinized couplings cannot alleviate the coincidence problem, however, they acquire stable late time accelerated solutions. We also discuss a coupled tachyon field with inverse square potential assuming linear coupling. (orig.)

  13. Getting started with PhantomJS

    CERN Document Server

    Beltran, Aries

    2013-01-01

    The book will follow aA standard tutorial approach, and will beas a complete guide detailing the major aspects of PhantomJS with particular focus on Website website Testingtesting.This book is written forIf you are a JavaScript developers who are is interested in developing applications that interact with various web services, and doing that using a headless browser, then this book is ideal for you. This book iswill also be good for you if you are planning to create a headless browser testing for your web application. Basic understanding of JavaScript is assumed.

  14. [Residual limb and phantom pain : Causes and therapeutic approaches].

    Science.gov (United States)

    Dwornik, G; Weiß, T; Hofmann, G O; Brückner, L

    2015-06-01

    Residual limb pain and phantom pain are severe complications following an amputation. Various reasons are responsible for these complaints. It must be distinguished between amputation stump pain, phantom sensations and phantom pain. In this paper we describe the most common reasons for stump pain and propose some non-operative therapeutic approaches. Furthermore path physiology and phantom pain therapy will be discussed. The recommendations offered in this paper are based on practical experience over three decades in a specialized out-patient department for patients with amputation injuries.

  15. [Phantom limb after amputation--overview and new knowledge].

    Science.gov (United States)

    Schmid, H J

    2000-01-13

    Almost all patients who have an extremity amputated will experience a phantom limb. Amputations of other parts of the body can also cause phantom sensations. One fourth of all women who undergo mastectomy relates phantom breast sensations. Phantoms are common following rectum amputation and may be significant as indicators of rectal tumor relapse. Visual phantoms can appear in patients who undergo eye amputation. Phantom phenomena occur after tooth extraction, ureterocystectomy, penectomy, plexus avulsion or spinal cord injury. The causes underlying phantom sensations are unknown. Sensory deprivation in animals causes reorganization of the cortical and subcortical maps: the areas representing the deprived input shrink and the neighbouring areas expand. The mapping allocates areas to represent the most used peripheral inputs. Every level of the nervous system seems to exhibit plasticity. The primary site seems to be the cortex. The cellular basis of plasticity is unclear. Significant sensory and motor reorganization was found in humans suffering phantom pain. There was a strong relationship between the amount of cortical reorganization and the intensity of phantom pain. These findings may influence the rehabilitation of the amputee. It was shown that pain and cortical reorganization can be reduced or even prevented by the active use of prostheses.

  16. Phantom Extremity Pain Responding to Stellate Ganglion Blockage: Case Report

    Directory of Open Access Journals (Sweden)

    Edip Gonullu

    2013-04-01

    Full Text Available Phantom extremity pain is that which continues to be felt in a non-existent extremity after amputation. The pathophysiological mechanism and etiology of phantom extremity pain are not exactly known, Phantom extremity pain affects the patients in physical and psycho-social aspects. This paper presents a patient with phantom extremity pain that had not responded to medical treatment. A stellate ganglion blockage was performed using lidocaine, bupivacaine and fentanyl and the patient%u2019s pain was observed to be reduced.

  17. Phantom Eye Syndrome: A Review of the Literature

    Directory of Open Access Journals (Sweden)

    Agda M. Andreotti

    2014-01-01

    Full Text Available The purpose of this literature review was to describe the main features of phantom eye syndrome in relation to their possible causes, symptoms, treatments, and influence of eye amputation on quality of life of anophthalmic patients. For this, a bibliographical research was performed in Pubmed database using the following terms: “eye amputation,” “eye trauma,” “phantom eye syndrome,” “phantom pain,” and “quality of life,” associated or not. Thirteen studies were selected, besides some relevant references contained in the selected manuscripts and other studies hallowed in the literature. Thus, 56 articles were included in this review. The phantom eye syndrome is defined as any sensation reported by the patient with anophthalmia, originated anophthalmic cavity. In phantom eye syndrome, at least one of these three symptoms has to be present: phantom vision, phantom pain, and phantom sensations. This syndrome has a direct influence on the quality of life of the patients, and psychological support is recommended before and after the amputation of the eyeball as well as aid in the treatment of the syndrome. Therefore, it is suggested that, for more effective treatment of phantom eye syndrome, drug therapy should be associated with psychological approach.

  18. Multi-layered tissue head phantoms for noninvasive optical diagnostics

    Directory of Open Access Journals (Sweden)

    M. S. Wróbel

    2015-05-01

    Full Text Available Extensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical properties of phantoms depend on their purpose. Nevertheless, they must accurately simulate specific tissues they are supposed to mimic. Many tissues and organs including head possess a multi-layered structure, with specific optical properties of each layer. However, such a structure is not always addressed in the present-day phantoms. In this paper, we focus on the development of a plain-parallel multi-layered phantom with optical properties (reduced scattering coefficient $\\mu_{s}^{\\prime}$ and absorption coefficient μa corresponding to the human head layers, such as skin, skull, and gray and white matter of the brain tissue. The phantom is intended for use in noninvasive diffuse near-infrared spectroscopy (NIRS of human brain. Optical parameters of the fabricated phantoms are reconstructed using spectrophotometry and inverse adding-doubling calculation method. The results show that polyvinyl chloride-plastisol (PVCP and zinc oxide (ZnO nanoparticles are suitable materials for fabrication of tissue mimicking phantoms with controlled scattering properties. Good matching was found between optical properties of phantoms and the corresponding values found in the literature.

  19. [Gelatine phantom for training of ultrasound guided vascular access].

    Science.gov (United States)

    Clemmesen, Louise; Bendtsen, Thomas F; Sloth, Erik; Oveland, Nils Petter; Knudsen, Lars

    2013-02-25

    This article describes the production of a low-cost training phantom for ultrasound guided invasive procedures of peripheral and central veins and presents a video of the process. The phantom can be adapted for use with other ultrasound techniques. It is a universal useful skill training tool for ultrasound guided invasive procedures. The phantom is easily made of concentrated gelatine. It is cheap and recyclable. The shelf life is prolonged by cold storage in a freezer. The gelatine phantom is a useful tool for practice of probe handling techniques and needle dexterity when placing peripheral and central venous catheters.

  20. [Development of a software for 3D virtual phantom design].

    Science.gov (United States)

    Zou, Lian; Xie, Zhao; Wu, Qi

    2014-02-01

    In this paper, we present a 3D virtual phantom design software, which was developed based on object-oriented programming methodology and dedicated to medical physics research. This software was named Magical Phan tom (MPhantom), which is composed of 3D visual builder module and virtual CT scanner. The users can conveniently construct any complex 3D phantom, and then export the phantom as DICOM 3.0 CT images. MPhantom is a user-friendly and powerful software for 3D phantom configuration, and has passed the real scene's application test. MPhantom will accelerate the Monte Carlo simulation for dose calculation in radiation therapy and X ray imaging reconstruction algorithm research.

  1. Phantom Limb Sensation (PLS) and Phantom Limb Pain (PLP) among Young Landmine Amputees.

    Science.gov (United States)

    Poor Zamany Nejatkermany, Mahtab; Modirian, Ehsan; Soroush, Mohammadreza; Masoumi, Mehdi; Hosseini, Maryam

    2016-01-01

    To determine the frequency of phantom limb sensation (PLS) and phantom limb pain (PLP) in children and young adults suffering landmine-related amputation. All youths with amputation due to landmine explosions participated in this study. The proportions of patients with phantom limb sensation/pain, intensity and frequency of pain were reported. Chi square test was used to examine the relationship between variables. Comparison of PLP and PLS between upper and lower amputation was done by unpaired t-test. There were 38 male and 3 female with the mean age of 15.8±2.4yr. The mean interval between injury and follow-up was 90.7±39.6 months. Twelve (44.4%) upper limb amputees and 11 (26.8%) lower limb amputees had PLS. Nine (33.3%) upper limb amputees and 7 (17.1%) lower limb amputees experienced PLP. Of 27 upper limb amputees, 6 (14.6%) and among 15 lower limb amputees, 6 (14.6%) had both PLS and PLP. One case suffered amputation of upper and lower limbs and was experiencing PLS and PLP in both parts. PLS had a significant difference between the upper and lower amputated groups. Significant relationship was observed between age of casualty and duration of injury with PLP. Phantom limb sensation and pain in young survivors of landmine explosions appear to be common, even years after amputation.

  2. Dual Energy Tomosynthesis breast phantom imaging

    Science.gov (United States)

    Koukou, V.; Martini, N.; Fountos, G.; Messaris, G.; Michail, C.; Kandarakis, I.; Nikiforidis, G.

    2017-12-01

    Dual energy (DE) imaging technique has been applied to many theoretical and experimental studies. The aim of the current study is to evaluate dual energy in breast tomosynthesis using commercial tomosynthesis system in terms of its potential to better visualize microcalcifications (μCs). The system uses a tungsten target X-ray tube and a selenium direct conversion detector. Low-energy (LE) images were acquired at different tube voltages (28, 30, 32 kV), while high-energy images at 49 kV. Fifteen projections, for the low- and high-energy respectively, were acquired without grid while tube scanned continuously. Log-subtraction algorithm was used in order to obtain the DE images with the weighting factor, w, derived empirically. The subtraction was applied to each pair of LE and HE slices after reconstruction. The TORMAM phantom was imaged with the different settings. Four regions-of-interest including μCs were identified in the inhomogeneous part of the phantom. The μCs in DE images were more clearly visible compared to the low-energy images. Initial results showed that DE tomosynthesis imaging is a promising modality, however more work is required.

  3. Phantom black holes and critical phenomena

    Energy Technology Data Exchange (ETDEWEB)

    Azreg-Aïnou, Mustapha [Engineering Faculty, Başkent University, Bağlıca Campus, Ankara (Turkey); Marques, Glauber T. [Universidade Federal Rural da Amazônia ICIBE-LASIC, Av. Presidente Tancredo Neves 2501, CEP 66077-901—Belém/PA (Brazil); Rodrigues, Manuel E., E-mail: azreg@baskent.edu.tr, E-mail: gtadaiesky@hotmail.com, E-mail: esialg@gmail.com [Faculdade de Ciências Exatas e Tecnologia, Universidade Federal do Pará, Campus Universitário de Abaetetuba, CEP 68440-000, Abaetetuba, Pará (Brazil)

    2014-07-01

    We consider the two classes cosh and sinh of normal and phantom black holes of Einstein-Maxwell-dilaton theory. The thermodynamics of these holes is characterized by heat capacities that may have both signs depending on the parameters of the theory. Leaving aside the normal Reissner-Nordström black hole, it is shown that only some phantom black holes of both classes exhibit critical phenomena. The two classes share a nonextremality, but special, critical point where the transition is continuous and the heat capacity, at constant charge, changes sign with an infinite discontinuity. This point yields a classification scheme for critical points. It is concluded that the two unstable and stable phases coexist on one side of the criticality state and disappear on the other side, that is, there is no configuration where only one phase exists. The sinh class has an extremality critical point where the entropy diverges. The transition from extremality to nonextremality with the charge held constant is accompanied by a loss of mass and an increase in the temperature. A special case of this transition is when the hole is isolated (microcanonical ensemble), it will evolve by emission of energy, which results in a decrease of its mass, to the final state of minimum mass and vanishing heat capacity. The Ehrenfest scheme of classification is inaccurate in this case but the generalized one due to Hilfer leads to conclude that the transition is of order less than unity. Fluctuations near criticality are also investigated.

  4. MRI compatible head phantom for ultrasound surgery.

    Science.gov (United States)

    Menikou, Georgios; Dadakova, Tetiana; Pavlina, Matt; Bock, Michael; Damianou, Christakis

    2015-03-01

    Develop a magnetic resonance imaging (MRI) compatible head phantom with acoustic attenuation closely matched to the human attenuation, and suitable for testing focused ultrasound surgery protocols. Images from an adult brain CT scan were used to segment the skull bone from adjacent cerebral tissue. The segmented model was manufactured in a 3-D printer using (Acrylonitrile Butadiene Styrene) ABS plastic. The cerebral tissue was mimicked by an agar-evaporated milk-silica gel (2% w/v-25% v/v-1.2% w/v) which was molded inside a skull model. The measured attenuation of the ABS skull was 16 dB/cm MHz. The estimated attenuation coefficient of the gel replicating brain tissue was 0.6 dB/cm MHz. The estimated agar-silica gel's T1 and T2 relaxation times in a 1.5 Tesla magnetic field were 852 ms and 66 ms respectively. The effectiveness of the skull to reduce ultrasonic heating was demonstrated using MRI thermometry. Due to growing interest in using MRI guided focused ultrasound (MRgFUS) for treating brain cancer and its application in sonothrombolysis, the proposed head phantom can be utilized as a very useful tool for evaluating ultrasonic protocols, thus minimizing the need for animal models and cadavers. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. [Atypical odontalgia - a little known phantom pain].

    Science.gov (United States)

    Türp, J C

    2001-02-01

    Atypical odontalgia (AO) was described in the dental literature more than 200 years ago, and it is included in most taxonomies and textbooks of pain. Nonetheless, it remains one of the most frequently misdiagnosed intraoral pain conditions. Due to similarities with phantom pain, AO is also referred to as "phantom tooth pain". AO is characterized by persistent throbbing pain in or around a former or present permanent tooth (preferably molars and premolars). Clinical and radiographic examination, however, does not reveal any organic cause of the pain. The complaints associated with AO usually begin after deafferentiation of primary afferent trigeminal nerve fibers, e. g., after pulp extirpation, apicectomy, or extraction of a tooth. AO is a diagnosis by exclusion. Patients and dentists must be aware of the fact that the therapeutic options are limited. AO is primarily managed with topically or systemically administered pharmacological agents. Unnecessary and harmful procedures around teeth and jaws must be avoided by all means. A concept was recently proposed which aims to unify a group of four types of orofacial pain under the term "idiopathic orofacial pain" (Woda & Pionchon 1999, 2000). These pain conditions - AO, atypical facial pain, burning mouth syndrome ("stomatodynia"), and subgroups of temporomandibular disorders ("idiopathic facial arthromyalgia") - are characterized by unknown etiology, but common clinical characteristics. It is to be hoped that the suggested classification will stimulate reflection on these enigmatic orofacial pain disorders.

  6. A Versatile and Reproducible Multi-Frequency Electrical Impedance Tomography System

    Directory of Open Access Journals (Sweden)

    James Avery

    2017-01-01

    Full Text Available A highly versatile Electrical Impedance Tomography (EIT system, nicknamed the ScouseTom, has been developed. The system allows control over current amplitude, frequency, number of electrodes, injection protocol and data processing. Current is injected using a Keithley 6221 current source, and voltages are recorded with a 24-bit EEG system with minimum bandwidth of 3.2 kHz. Custom PCBs interface with a PC to control the measurement process, electrode addressing and triggering of external stimuli. The performance of the system was characterised using resistor phantoms to represent human scalp recordings, with an SNR of 77.5 dB, stable across a four hour recording and 20 Hz to 20 kHz. In studies of both haeomorrhage using scalp electrodes, and evoked activity using epicortical electrode mats in rats, it was possible to reconstruct images matching established literature at known areas of onset. Data collected using scalp electrode in humans matched known tissue impedance spectra and was stable over frequency. The experimental procedure is software controlled and is readily adaptable to new paradigms. Where possible, commercial or open-source components were used, to minimise the complexity in reproduction. The hardware designs and software for the system have been released under an open source licence, encouraging contributions and allowing for rapid replication.

  7. Generation of voxelized breast phantoms from surgical mastectomy specimens.

    Science.gov (United States)

    O'Connor, J Michael; Das, Mini; Dider, Clay S; Mahd, Mufeed; Glick, Stephen J

    2013-04-01

    In the research and development of dedicated tomographic breast imaging systems, digital breast object models, also known as digital phantoms, are useful tools. While various digital breast phantoms do exist, the purpose of this study was to develop a realistic high-resolution model suitable for simulating three-dimensional (3D) breast imaging modalities. The primary goal was to design a model capable of producing simulations with realistic breast tissue structure. The methodology for generating an ensemble of digital breast phantoms was based on imaging surgical mastectomy specimens using a benchtop, cone-beam computed tomography system. This approach allowed low-noise, high-resolution projection views of the mastectomy specimens at each angular position. Reconstructions of these projection sets were processed using correction techniques and diffusion filtering prior to segmentation into breast tissue types in order to generate phantoms. Eight compressed digital phantoms and 20 uncompressed phantoms from which an additional 96 pseudocompressed digital phantoms with voxel dimensions of 0.2 mm(3) were generated. Two distinct tissue classification models were used in forming breast phantoms. The binary model classified each tissue voxel as either adipose or fibroglandular. A multivalue scaled model classified each tissue voxel as percentage of adipose tissue (range 1%-99%). Power spectral analysis was performed to compare simulated reconstructions using the breast phantoms to the original breast specimen reconstruction, and fits were observed to be similar. The digital breast phantoms developed herein provide a high-resolution anthropomorphic model of the 3D uncompressed and compressed breast that are suitable for use in evaluating and optimizing tomographic breast imaging modalities. The authors believe that other research groups might find the phantoms useful, and therefore they offer to make them available for wider use.

  8. 21 CFR 892.1950 - Radiographic anthropomorphic phantom.

    Science.gov (United States)

    2010-04-01

    ... (CONTINUED) MEDICAL DEVICES RADIOLOGY DEVICES Diagnostic Devices § 892.1950 Radiographic anthropomorphic phantom. (a) Identification. A radiographic anthropomorphic phantom is a device intended for medical... (general controls). The device is exempt from the premarket notification procedures in subpart E of part...

  9. Mapping phantom movement representations in the motor cortex of amputees.

    Science.gov (United States)

    Mercier, Catherine; Reilly, Karen T; Vargas, Claudia D; Aballea, Antoine; Sirigu, Angela

    2006-08-01

    Limb amputation results in plasticity of connections between the brain and muscles, with the cortical motor representation of the missing limb seemingly shrinking, to the presumed benefit of remaining body parts that have cortical representations adjacent to the now-missing limb. Surprisingly, the corresponding perceptual representation does not suffer a similar fate but instead persists as a phantom limb endowed with sensory and motor qualities. How can cortical reorganization after amputation be reconciled with the maintenance of a motor representation of the phantom limb in the brain? In an attempt to answer this question we explored the relationship between the cortical representation of the remaining arm muscles and that of phantom movements. Using transcranial magnetic stimulation (TMS) we systematically mapped phantom movement perceptions while simultaneously recording stump muscle activity in three above-elbow amputees. TMS elicited sensations of movement in the phantom hand when applied over the presumed hand area of the motor cortex. In one subject the amplitude of the perceived movement was positively correlated with the intensity of stimulation. Interestingly, phantom limb movements that the patient could not produce voluntarily were easily triggered by TMS, suggesting that the inability to voluntarily move the phantom is not equivalent to a loss of the corresponding movement representation. We suggest that hand movement representations survive in the reorganized motor area of amputees even when these cannot be directly accessed. The activation of these representations is probably necessary for the experience of phantom movement.

  10. Anisotropic Bianchi-I universe with phantom field and cosmological ...

    Indian Academy of Sciences (India)

    We study an anisotropic Bianchi-I universe in the presence of a phantom field and a cosmological constant. Cosmological solutions are obtained when the kinetic energy of the phantom field is of the order of anisotropy and dominates over the potential energy of the field. The anisotropy of the universe decreases and the ...

  11. Cosmological model of interacting phantom and Yang–Mills fields

    Indian Academy of Sciences (India)

    interacting with a phantom field in FRW cosmology. Using the specific solution of YM equation previously considered in FRW cosmology [30–34], we generalize the model investigated in [30] in the case of interacting phantom and YM fields. This allows us to obtain some exact solutions for the accelerated expansion of FRW ...

  12. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry

    NARCIS (Netherlands)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-01-01

    Hybrid computational phantoms combine voxel-based and simplified equation-based modelling approaches to provide unique advantages and more realism for the construction of anthropomorphic models. In this work, a methodology and C++ code are developed to generate hybrid computational phantoms covering

  13. Building and assessing anatomically relevant phantoms for neonatal transcranial ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Memoli, G; Sadhoo, N; Gelat, P; Shaw, A [Acoustics and Ionising Radiation Division, National Physical Laboratory, Teddington (United Kingdom); Gatto, M; Harris, R A, E-mail: gianluca.memoli@npl.co.uk [Wolfson School of Mechanical and Manufacturing Engineering, Loughborough University, Loughborough (United Kingdom)

    2011-02-01

    This study describes the design and construction of a clinically relevant phantom to survey the temperature increase caused by ultrasound equipment, as currently used in neonatal head-scanning in the UK. The phantom is an ellipsoid of bone-mimic material, filled with brain-mimic; a circular hole in the external surface mimicks the fontanel, through which most clinically relevant scans are made. Finite-element simulations were used to identify possible hot spots and decide the most effective thermocouple positions within the phantom to investigate temperature rise during a typical scan. Novel materials were purposively designed to simulate key acoustic and thermal properties. Three Dimensional Printing (3DP) was employed for the fabrication of the skull phantom, and a specific strategy was successfully pursued to embed a thermocouple within the 3DP skull phantom during the manufacturing process. An in-process Non-Destructive Analysis (NDA) was used to assess the correct position of the deposited thermocouple inside the fabricated skull phantom. The temperature increase in the phantom for a typical trans-fontanellar scan is also presented here. The current phantom will be used in a hospital survey in the UK and, in its final design, will allow for a more reliable evaluation of ultrasound heating than is currently possible.

  14. Evaluation of DQA for tomography using 3D volumetric phantom

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sang Uk [Dept. of Radiation Oncology, Catholic University of Incheon St. Mary' s Hospital, Incheon (Korea, Republic of); Kim, Jeong Koo [Dept. of Radiological Science, Hanseo University, Seosan (Korea, Republic of)

    2016-12-15

    The study investigates the necessity of 3 dimensional dose distribution evaluation instead of point dose and 2 dimensional dose distribution evaluation. Treatment plans were generated on the RANDO phantom to measure the precise dose distribution of the treatment site 0.5, 1, 1.5, 2, 2.5, 3 cm with the prescribed dose; 1,200 cGy, 5 fractions. Gamma analysis (3%/3 mm, 2%/2 mm) of dose distribution was evaluated with gafchromic EBT2 film and ArcCHECK phantom. The average error of absolute dose was measured at 0.76±0.59% and 1.37±0.76% in cheese phantom and ArcCHECK phantom respectively. The average passing ratio for 3%/3 mm were 97.72±0.02% and 99.26±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. The average passing ratio for 2%/2 mm were 94.21±0.02% and 93.02±0.01% in gafchromic EBT2 film and ArcCHECK phantom respectively. There was a more accurate dose distribution of 3D volume phantom than cheese phantom in patients DQA using tomotherapy. Therefor it should be evaluated simultaneously 3 dimensional dose evaluation on target and peripheral area in rotational radiotherapy such as tomotherapy.

  15. Phantom limb phenomenon as an example of body image distortion

    Directory of Open Access Journals (Sweden)

    Razmus Magdalena

    2017-06-01

    Full Text Available Introduction: The perception of one’s own body, its mental representation, and emotional attitude to it are the components of so-called “body image” [1]. The aim of the research was to analyse phantom pain and non-painful phantom sensations as results of limb loss and to explain them in terms of body image distortion.

  16. Usefulness of milnacipran in treating phantom limb pain

    Directory of Open Access Journals (Sweden)

    Matsumoto Y

    2012-11-01

    Full Text Available Yasuhide Nagoshi,1 Akira Watanabe,1 Saiko Inoue,1 Tomoki Kuroda,2 Mitsuo Nakamura,3 Yoshitake Matsumoto,4 Kenji Fukui31Department of Psychiatry (Psychosomatic Medicine, Kyoto First Red Cross Hospital, Kyoto, Japan; 2Gojouyama Hospital, Nara, Japan; 3Department of Psychiatry, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan; 4Matsumoto Clinic, Kyoto, JapanBackground: Amputation of an extremity often results in the sensation of a “phantom limb” where the patient feels that the limb that has been amputated is still present. This is frequently accompanied by “phantom limb pain”. We report here the use of milnacipran, a serotonin and norepinephrine reuptake inhibitor, to treat phantom limb pain after amputation of injured or diseased limbs in three patients.Methods and results: The severity of phantom pain before and during treatment was quantified using a visual analog scale. In one case, phantom limb pain responded partially to treatment with high doses of paroxetine, and then replacement with milnacipran further improved the pain relief and long-term full pain relief was achieved. In the two other cases, milnacipran was used as first-line treatment and phantom limb pain responded rapidly.Conclusion: These results suggest that milnacipran administration may be useful in phantom limb pain, possibly as a first-line treatment.Keywords: milnacipran, paroxetine, phantom limb pain, selective serotonin reuptake inhibitor (SSRI, serotonin and norepinephrine reuptake inhibitor (SNRI

  17. An MRI digital brain phantom for validation of segmentation methods.

    Science.gov (United States)

    Alfano, Bruno; Comerci, Marco; Larobina, Michele; Prinster, Anna; Hornak, Joseph P; Selvan, S Easter; Amato, Umberto; Quarantelli, Mario; Tedeschi, Gioacchino; Brunetti, Arturo; Salvatore, Marco

    2011-06-01

    Knowledge of the exact spatial distribution of brain tissues in images acquired by magnetic resonance imaging (MRI) is necessary to measure and compare the performance of segmentation algorithms. Currently available physical phantoms do not satisfy this requirement. State-of-the-art digital brain phantoms also fall short because they do not handle separately anatomical structures (e.g. basal ganglia) and provide relatively rough simulations of tissue fine structure and inhomogeneity. We present a software procedure for the construction of a realistic MRI digital brain phantom. The phantom consists of hydrogen nuclear magnetic resonance spin-lattice relaxation rate (R1), spin-spin relaxation rate (R2), and proton density (PD) values for a 24 × 19 × 15.5 cm volume of a "normal" head. The phantom includes 17 normal tissues, each characterized by both mean value and variations in R1, R2, and PD. In addition, an optional tissue class for multiple sclerosis (MS) lesions is simulated. The phantom was used to create realistic magnetic resonance (MR) images of the brain using simulated conventional spin-echo (CSE) and fast field-echo (FFE) sequences. Results of mono-parametric segmentation of simulations of sequences with different noise and slice thickness are presented as an example of possible applications of the phantom. The phantom data and simulated images are available online at http://lab.ibb.cnr.it/. Copyright © 2011 Elsevier B.V. All rights reserved.

  18. Phantom limb pain: a case of maladaptive CNS plasticity?

    DEFF Research Database (Denmark)

    Flor, Herta; Nikolajsen, Lone; Jensen, Troels Staehelin

    2006-01-01

    Phantom pain refers to pain in a body part that has been amputated or deafferented. It has often been viewed as a type of mental disorder or has been assumed to stem from pathological alterations in the region of the amputation stump. In the past decade, evidence has accumulated that phantom pain...

  19. Phantom jam avoidance through in-car speed advice

    NARCIS (Netherlands)

    Suijs, L.C.W.; Wismans, Luc Johannes Josephus; Krol, L.; van Berkum, Eric C.

    2015-01-01

    The existence of phantom jams can be explained following the definition of Kerner & Konhäuser (1993) who state that a phantom jam occurs without the existence of a physical bottleneck and is caused by the imperfect driving style of road users under metastable traffic conditions. In order to prevent

  20. THE EFFECT OF PHANTOM GROUPS ON GENETIC TREND

    African Journals Online (AJOL)

    Helena Theron

    North America was a combination between the United States of. America (USA) and Canada ... then be assigned to the following phantom parent group: North America x (1981-1985) x Sire-of-sire. Note ..... animals with phantom parent groups in the analysis, the genetic level of migrant animals is separated from that of base ...

  1. The impact of anthropometric patient-phantom matching on organ dose: A hybrid phantom study for fluoroscopy guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Perry B.; Geyer, Amy; Borrego, David; Ficarrotta, Kayla; Johnson, Kevin; Bolch, Wesley E. [Nuclear and Radiological Engineering, University of Florida, Gainesville, Florida 32611 (United States); Radiology, University of Florida, Jacksonville, Florida 32209 (United States); Department of Nuclear and Radiological/Biomedical Engineering, University of Florida, Gainesville, Florida 32611-8300 (United States)

    2011-02-15

    Purpose: To investigate the benefits and limitations of patient-phantom matching for determining organ dose during fluoroscopy guided interventions. Methods: In this study, 27 CT datasets representing patients of different sizes and genders were contoured and converted into patient-specific computational models. Each model was matched, based on height and weight, to computational phantoms selected from the UF hybrid patient-dependent series. In order to investigate the influence of phantom type on patient organ dose, Monte Carlo methods were used to simulate two cardiac projections (PA/left lateral) and two abdominal projections (RAO/LPO). Organ dose conversion coefficients were then calculated for each patient-specific and patient-dependent phantom and also for a reference stylized and reference hybrid phantom. The coefficients were subsequently analyzed for any correlation between patient-specificity and the accuracy of the dose estimate. Accuracy was quantified by calculating an absolute percent difference using the patient-specific dose conversion coefficients as the reference. Results: Patient-phantom matching was shown most beneficial for estimating the dose to heavy patients. In these cases, the improvement over using a reference stylized phantom ranged from approximately 50% to 120% for abdominal projections and for a reference hybrid phantom from 20% to 60% for all projections. For lighter individuals, patient-phantom matching was clearly superior to using a reference stylized phantom, but not significantly better than using a reference hybrid phantom for certain fields and projections. Conclusions: The results indicate two sources of error when patients are matched with phantoms: Anatomical error, which is inherent due to differences in organ size and location, and error attributed to differences in the total soft tissue attenuation. For small patients, differences in soft tissue attenuation are minimal and are exceeded by inherent anatomical differences

  2. Validation of phantom-based harmonization for patient harmonization.

    Science.gov (United States)

    Panetta, Joseph V; Daube-Witherspoon, Margaret E; Karp, Joel S

    2017-07-01

    To improve the precision of multicenter clinical trials, several efforts are underway to determine scanner-specific parameters for harmonization using standardized phantom measurements. The goal of this study was to test the correspondence between quantification in phantom and patient images and validate the use of phantoms for harmonization of patient images. The National Electrical Manufacturers' Association image quality phantom with hot spheres was scanned on two time-of-flight PET scanners. Whole-body [18 F]-fluorodeoxyglucose (FDG)-PET scans were acquired of subjects on the same systems. List-mode events from spheres (diam.: 10-28 mm) measured in air on each scanner were embedded into the phantom and subject list-mode data from each scanner to create lesions with known uptake with respect to the local background in the phantom and each subject's liver and lung regions, as a proxy to characterize true lesion quantification. Images were analyzed using the contrast recovery coefficient (CRC) typically used in phantom studies and serving as a surrogate for the standardized uptake value used clinically. Postreconstruction filtering (resolution recovery and Gaussian smoothing) was applied to determine if the effect on the phantom images translates equivalently to subject images. Three postfiltering strategies were selected to harmonize the CRCmean or CRCmax values between the two scanners based on the phantom measurements and then applied to the subject images. Both the average CRCmean and CRCmax values for lesions embedded in the lung and liver in four subjects (BMI range 25-38) agreed to within 5% with the CRC values for lesions embedded in the phantom for all lesion sizes. In addition, the relative changes in CRCmean and CRCmax resulting from the application of the postfilters on the subject and phantom images were consistent within measurement uncertainty. Further, the root mean squared percent difference (RMSpd ) between CRC values on the two scanners

  3. Cortical depression and potentiation: basic mechanisms for phantom pain.

    Science.gov (United States)

    Zhuo, Min

    2012-12-01

    People experience the feeling of the missing body part long after it has been removed after amputation are known as phantom limb sensations. These sensations can be painful, sometimes becoming chronic and lasting for several years (or called phantom pain). Medical treatment for these individuals is limited. Recent neurobiological investigations of brain plasticity after amputation have revealed new insights into the changes in the brain that may cause phantom limb sensations and phantom pain. In this article, I review recent progresses of the cortical plasticity in the anterior cingulate cortex (ACC), a critical cortical area for pain sensation, and explore how they are related to abnormal sensory sensations such as phantom pain. An understanding of these alterations may guide future research into medical treatment for these disorders.

  4. Tissue-like phantoms for quantitative birefringence imaging.

    Science.gov (United States)

    Liu, Xinyu; Beaudette, Kathy; Wang, Xianghong; Liu, Linbo; Bouma, Brett E; Villiger, Martin

    2017-10-01

    Birefringence imaging, including polarization sensitive optical coherence tomography (PS-OCT), can provide valuable insight into the microscopic structure and organization of many biological tissues. In this paper, we report on a method to fabricate tissue-like birefringence phantoms for such imaging modalities. We utilize the photo-elastic effect, wherein birefringence is induced by stretching a polymer sample after heating it above its glass-transition temperature. The cooled samples stably exhibit homogeneous birefringence, and were assembled into phantoms containing multiple well-defined regions of distinct birefringence. We present planar slab phantoms for microscopy applications and cylindrical phantoms for catheter-based imaging and demonstrate quantitative analysis of the birefringence within individual regions of interest. Birefringence phantoms enable testing, validating, calibrating, and improving PS-OCT acquisition systems and reconstruction strategies.

  5. Surgical phantom for off-pump mitral valve replacement

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Guiraudon, Gerard M.; Jones, Doug L.; Campbell, Gordon; Peters, Terry M.

    2011-03-01

    Off-pump, intracardiac, beating heart surgery has the potential to improve patient outcomes by eliminating the need for cardiopulmonary bypass and aortic cross clamping but it requires extensive image guidance as well as the development of specialized instrumentation. Previously, developments in image guidance and instrumentation were validated on either a static phantom or in vivo through porcine models. This paper describes the design and development of a surgical phantom for simulating off-pump mitral valve replacement inside the closed beating heart. The phantom allows surgical access to the mitral annulus while mimicking the pressure inside the beating heart. An image guidance system using tracked ultrasound, magnetic instrument tracking and preoperative models previously developed for off-pump mitral valve replacement is applied to the phantom. Pressure measurements and ultrasound images confirm the phantom closely mimics conditions inside the beating heart.

  6. Phantom space-times in fake supergravity

    Science.gov (United States)

    Bu Taam, Maryam; Sabra, Wafic A.

    2015-12-01

    We discuss phantom metrics admitting Killing spinors in fake N = 2, D = 4 supergravity coupled to vector multiplets. The Abelian U (1) gauge fields in the fake theory have kinetic terms with the wrong sign. We solve the Killing spinor equations for the standard and fake theories in a unified fashion by introducing a parameter which distinguishes between the two theories. The solutions found are fully determined in terms of algebraic conditions, the so-called stabilisation equations, in which the symplectic sections are related to a set of functions. These functions are harmonic in the case of the standard supergravity theory and satisfy the wave-equation in flat (2 + 1)-space-time in the fake theory. Explicit examples are given for the minimal models with quadratic prepotentials.

  7. Phantom space–times in fake supergravity

    Directory of Open Access Journals (Sweden)

    Maryam Bu Taam

    2015-12-01

    Full Text Available We discuss phantom metrics admitting Killing spinors in fake N=2, D=4 supergravity coupled to vector multiplets. The Abelian U(1 gauge fields in the fake theory have kinetic terms with the wrong sign. We solve the Killing spinor equations for the standard and fake theories in a unified fashion by introducing a parameter which distinguishes between the two theories. The solutions found are fully determined in terms of algebraic conditions, the so-called stabilisation equations, in which the symplectic sections are related to a set of functions. These functions are harmonic in the case of the standard supergravity theory and satisfy the wave-equation in flat (2+1-space–time in the fake theory. Explicit examples are given for the minimal models with quadratic prepotentials.

  8. Phantom limb pain: a nursing perspective.

    Science.gov (United States)

    Virani, Anila; Green, Theresa; Turin, Tanvir C

    2014-09-09

    Phantom limb pain (PLP) is a neuropathic pain condition occurring after amputation of a limb. PLP affects amputees' quality of life and results in loss of productivity and psychological distress. The origin of pain from a non-existing limb creates a challenging situation for both patients and nurses. It is imperative to provide patients and nurses with the knowledge that PLP is a real phenomenon that requires care and treatment. This knowledge will lead to reduced problems for patients by allowing them to talk about PLP and ask for help when needed. Understanding of this phenomenon will enable nurses to appreciate the unique features of this form of neuropathic pain and apply appropriate techniques to promote effective pain management. Performing accurate and frequent assessments to understand the unique characteristics of PLP, displaying a non-judgemental attitude towards patients and teaching throughout the peri-operative process are significant nursing interventions.

  9. Validation study of the thorax phantom Lungman for optimization purposes

    Science.gov (United States)

    Rodríguez Pérez, Sunay; Marshall, Nicholas W.; Struelens, Lara; Bosmans, Hilde

    2017-03-01

    This work aims to investigate the advantages and limitations of the Kyoto Kagaku thorax phantom Lungman for use in chest radiography optimization studies. First, patient survey data were gathered for chest posterior anterior (PA) and lateral (LAT) examinations in a standard chest X-ray room over a period of one year, using a Caesium Iodide (CsI) based flat panel detector with automatic exposure control (AEC). Parameters surveyed included exposure index (EI), dose area product (DAP) and AEC exposure time. PA and LAT projections of the phantom were then compared to these values. Additionally, the equivalence in millimetres of poly (methyl methacrylate) (PMMA) was established for the different regions of the Lungman phantom (lungs and mediastinum). Finally, a voxel model of the Lungman phantom was developed by the segmentation of a volumetric dataset of the phantom acquired using CT scanning. Subsequently, the model was used in Monte Carlo simulations with PENELOPE/penEasy code to calculate the energy deposited in the organs of the phantom. This enabled comparison of the phantom tissue-equivalent materials with materials defined by ICRP 89 in terms of energy deposition. For the survey data, close agreement was found between phantom and the median values for the patient data (deviations ranged from 4% to 31%, one outlier). The phantom lung region is equivalent to 89 mm to 106 mm of PMMA, depending on tube voltage. Energy deposited in the phantom material compared to those for ICRP defined material differed by at most 36% in AP irradiations and 49% in PA irradiations.

  10. Phantom breast sensations and phantom breast pain : A 2-year prospective study and a methodological analysis of literature

    NARCIS (Netherlands)

    Dijkstra, P.U.; Rietman, J.S.; Geertzen, J.H.B.

    The first aim of this study was to assess prospectively the incidence of phantom breast sensations (PB sensations) and phantom breast pain (PB pain) in a sample of patients treated for breast cancer (n = 204) by means of a modified radical mastectomy (n = 82). Patients were assessed 6 weeks, 6, 12

  11. Phantom breast sensations and phantom breast pain: A 2-year prospective study and a methodological analysis of literature

    NARCIS (Netherlands)

    Dijkstra, P.U.; Rietman, Johan Swanik; Geertzen, J.H.B.

    The first aim of this study was to assess prospectively the incidence of phantom breast sensations (PB sensations) and phantom breast pain (PB pain) in a sample of patients treated for breast cancer (n = 204) by means of a modified radical mastectomy (n = 82). Patients were assessed 6 weeks, 6, 12

  12. Quantitative magnetic resonance imaging phantoms: A review and the need for a system phantom.

    Science.gov (United States)

    Keenan, Kathryn E; Ainslie, Maureen; Barker, Alex J; Boss, Michael A; Cecil, Kim M; Charles, Cecil; Chenevert, Thomas L; Clarke, Larry; Evelhoch, Jeffrey L; Finn, Paul; Gembris, Daniel; Gunter, Jeffrey L; Hill, Derek L G; Jack, Clifford R; Jackson, Edward F; Liu, Guoying; Russek, Stephen E; Sharma, Samir D; Steckner, Michael; Stupic, Karl F; Trzasko, Joshua D; Yuan, Chun; Zheng, Jie

    2018-01-01

    The MRI community is using quantitative mapping techniques to complement qualitative imaging. For quantitative imaging to reach its full potential, it is necessary to analyze measurements across systems and longitudinally. Clinical use of quantitative imaging can be facilitated through adoption and use of a standard system phantom, a calibration/standard reference object, to assess the performance of an MRI machine. The International Society of Magnetic Resonance in Medicine AdHoc Committee on Standards for Quantitative Magnetic Resonance was established in February 2007 to facilitate the expansion of MRI as a mainstream modality for multi-institutional measurements, including, among other things, multicenter trials. The goal of the Standards for Quantitative Magnetic Resonance committee was to provide a framework to ensure that quantitative measures derived from MR data are comparable over time, between subjects, between sites, and between vendors. This paper, written by members of the Standards for Quantitative Magnetic Resonance committee, reviews standardization attempts and then details the need, requirements, and implementation plan for a standard system phantom for quantitative MRI. In addition, application-specific phantoms and implementation of quantitative MRI are reviewed. Magn Reson Med 79:48-61, 2018. © 2017 International Society for Magnetic Resonance in Medicine. © 2017 International Society for Magnetic Resonance in Medicine.

  13. Evaluation of a portable image overlay projector for the visualisation of surgical navigation data: phantom studies.

    Science.gov (United States)

    Gavaghan, K; Oliveira-Santos, T; Peterhans, M; Reyes, M; Kim, H; Anderegg, S; Weber, S

    2012-07-01

    Presenting visual feedback for image-guided surgery on a monitor requires the surgeon to perform time-consuming comparisons and diversion of sight and attention away from the patient. Deficiencies in previously developed augmented reality systems for image-guided surgery have, however, prevented the general acceptance of any one technique as a viable alternative to monitor displays. This work presents an evaluation of the feasibility and versatility of a novel augmented reality approach for the visualisation of surgical planning and navigation data. The approach, which utilises a portable image overlay device, was evaluated during integration into existing surgical navigation systems and during application within simulated navigated surgery scenarios. A range of anatomical models, surgical planning data and guidance information taken from liver surgery, cranio-maxillofacial surgery, orthopaedic surgery and biopsy were displayed on patient-specific phantoms, directly on to the patient's skin and on to cadaver tissue. The feasibility of employing the proposed augmented reality visualisation approach in each of the four tested clinical applications was qualitatively assessed for usability, visibility, workspace, line of sight and obtrusiveness. The visualisation approach was found to assist in spatial understanding and reduced the need for sight diversion throughout the simulated surgical procedures. The approach enabled structures to be identified and targeted quickly and intuitively. All validated augmented reality scenes were easily visible and were implemented with minimal overhead. The device showed sufficient workspace for each of the presented applications, and the approach was minimally intrusiveness to the surgical scene. The presented visualisation approach proved to be versatile and applicable to a range of image-guided surgery applications, overcoming many of the deficiencies of previously described AR approaches. The approach presents an initial step

  14. Hubungan Phantom Vibration Syndrome Terhadap Sleep Disorder dan Kondisi Stress

    Directory of Open Access Journals (Sweden)

    Ajeng Yeni Setianingrum

    2017-10-01

    Full Text Available Phantom vibration syndrome is a condition where a person would feel the sensation of vibration of a cell phone as if there were incoming notification but the fact is not. This research investigated the relationship between phantom vibration syndromes, sleep disorder and stress condition. Questionnaires were distributed to 120 participants with age range 18 to 23 years old. Data of participants showed that all of participants using a smart mobile phone and 24% of them have more than one cell phone. Time usage of cell phone is at least 1 hour. 23% of participants using a cell phone for social media activity, followed by 21% related to entertainment (music, video and games. The results showed a positive relationship between phantom vibration syndrome, sleep disorder and stress condition. Insomnia contributed a greater influence on stress condition. However, the phantom vibration syndrome is more directly affecting the sleep apnea compared to insomnia and stress condition. Therefore, the phantom vibration syndrome more affects stress condition indirectly, through sleep disorder (sleep apnea and insomnia. Consequently, phantom vibration syndrome has a strong relationship with stress condition at the time of the phantom vibration syndrome can cause sleep disorder.

  15. Studies on Phantom Vibration and Ringing Syndrome among Postgraduate Students

    Directory of Open Access Journals (Sweden)

    Atul Kumar Goyal

    2015-03-01

    Full Text Available Phantom vibrations and ringing of mobile phones are prevalent hallucinations in the general population. They might be considered as a normal brain mechanism. The aim of this study was to establish the prevalence of Phantom vibrations and ringing syndrome among students and to assess factors associated it. The survey of 300 postgraduate students belonging to different field of specialization was conducted at Kurukshetra University. 74% of students were found to have both Phantom vibrations and ringing syndrome. Whereas 17% of students felt Phantom vibration exclusively and 4% students face only Phantom ringing syndrome. Both the syndrome occurs more fervent in students who kept their mobile phone in shirt or jean pocket than to who kept mobile in handbag. 75% of students felt vibration or ringing even when the phone is switched off or phone was not in their pocket. Also the frequency of both the syndrome is directly proportional to the duration of mobile phone use and person emotional behavior. Although most of students agree that the Phantom syndrome did not bother them but some students deals with anxiety when they feel symptoms associated with Phantom syndrome. By using mobile phones in proper way, one can avoid these syndromes, or at least can ameliorate the symptoms.

  16. Rapid prototyping of biomimetic vascular phantoms for hyperspectral reflectance imaging.

    Science.gov (United States)

    Ghassemi, Pejhman; Wang, Jianting; Melchiorri, Anthony J; Ramella-Roman, Jessica C; Mathews, Scott A; Coburn, James C; Sorg, Brian S; Chen, Yu; Pfefer, T Joshua

    2015-01-01

    The emerging technique of rapid prototyping with three-dimensional (3-D) printers provides a simple yet revolutionary method for fabricating objects with arbitrary geometry. The use of 3-D printing for generating morphologically biomimetic tissue phantoms based on medical images represents a potentially major advance over existing phantom approaches. Toward the goal of image-defined phantoms, we converted a segmented fundus image of the human retina into a matrix format and edited it to achieve a geometry suitable for printing. Phantoms with vessel-simulating channels were then printed using a photoreactive resin providing biologically relevant turbidity, as determined by spectrophotometry. The morphology of printed vessels was validated by x-ray microcomputed tomography. Channels were filled with hemoglobin (Hb) solutions undergoing desaturation, and phantoms were imaged with a near-infrared hyperspectral reflectance imaging system. Additionally, a phantom was printed incorporating two disjoint vascular networks at different depths, each filled with Hb solutions at different saturation levels. Light propagation effects noted during these measurements—including the influence of vessel density and depth on Hb concentration and saturation estimates, and the effect of wavelength on vessel visualization depth—were evaluated. Overall, our findings indicated that 3-D-printed biomimetic phantoms hold significant potential as realistic and practical tools for elucidating light–tissue interactions and characterizing biophotonic system performance.

  17. Individual differences in response to phantom limb movement therapy.

    Science.gov (United States)

    McAvinue, Laura P; Robertson, Ian H

    2011-01-01

    Phantom limb pain (PLP) is a distressing condition experienced by many amputees. The purpose of this study was to investigate whether motor imagery could be used to treat PLP. Four single case studies were conducted. The participants kept a pain diary in which they recorded the intensity of their PLP during a baseline period, general motor imagery training, phantom limb movement therapy and a follow-up period. Qualitative and quantitative (i.e. interrupted time series) analyses were employed to determine whether phantom limb movement therapy had a significant effect on PLP intensity. Phantom limb movement therapy significantly reduced intensity of PLP in one participant. One participant gained occasional relief by doing phantom limb movement therapy exercises but did not experience an overall reduction in PLP intensity. The third participant did not experience any relief and the fourth participant reported experiencing the re-emergence of an old pain. The results display individual differences in response to phantom limb movement therapy. Individual differences are discussed in the context of motor imagery ability and the phantom limb phenomenon as a multi-dimensional disorder.

  18. Pharmacologic interventions for treating phantom limb pain.

    Science.gov (United States)

    Alviar, Maria Jenelyn M; Hale, Tom; Dungca, Monalisa

    2016-10-14

    This is an updated version of the original Cochrane review published in Issue 12, 2011. Phantom limb pain (PLP) is pain that arises in the missing limb after amputation and can be severe, intractable, and disabling. Various medications have been studied in the treatment of phantom pain. There is currently uncertainty in the optimal pharmacologic management of PLP. This review aimed to summarise the evidence of effectiveness of pharmacologic interventions in treating PLP. For this update, we searched the Cochrane Central Register of Controlled Trials (CENTRAL, the Cochrane Library), MEDLINE, and Embase for relevant studies. We ran the searches for the original review in September 2011 and subsequent searches for this update up to April 2016. We sought additional studies from clinical trials databases and reference lists of retrieved papers. We included randomised and quasi-randomised trials studying the effectiveness of pharmacologic interventions compared with placebo, another active treatment, or no treatment, in established PLP. We considered the following outcomes: change in pain intensity, function, sleep, depression or mood, quality of life, adverse events, treatment satisfaction, and withdrawals from the study. We independently assessed issues of study quality and extracted efficacy and adverse event data. Due to the wide variability in the studies, we did not perform a meta-analysis for all the interventions and outcomes, but attempted to pool the results of some studies where possible. We prepared a qualitative description and narrative summary of results. We assessed clinical heterogeneity by making qualitative comparisons of the populations, interventions, outcomes/outcome measures, and methods. We added only one new study with 14 participants to this updated review. We included a 14 studies (10 with low risk of bias and 4 with unclear risk of bias overall) with a total of 269 participants. We added another drug class, botulinum neurotoxins (BoNTs), in

  19. A dosimetric study on slab-pinewood-slab phantom for developing the heterogeneous chest phantom mimicking actual human chest

    Directory of Open Access Journals (Sweden)

    Om Prakash Gurjar

    2017-01-01

    Full Text Available The aim is to study the density, isodose depths, and doses at different points in slab-pinewood-slab (SPS phantom, solid phantom SP34 (made up of polystyrene, and chest level of actual patient for developing heterogeneous chest phantom mimicking thoracic region of human body. A 6 MV photon beam of field size of 10 cm×10 cm was directed perpendicular to the surface of computed tomography (CT images of chest level of patient, SPS phantom, and SP34 phantom. Dose was calculated using anisotropic analytical algorithm. Hounsfield units were used to calculate the density of each medium. Isodose depths in all the three sets of CT images were measured. Variations between planned doses on treatment planning system (TPS and measured on linear accelerator (LA were calculated for three points, namely, near slab-pinewood interfaces (6 and 18 cm depths and 10 cm depth in SPS phantom and at the same depths in SP34 phantom. Density of pinewood, SP34 slabs, chest wall, lung, and soft tissue behind lung was measured as 0.329 ± 0.08, 0.999 ± 0.02, 0.898 ± 0.02, 0.291 ± 0.12, and 1.002 ± 0.03 g/cc, respectively. Depths of 100% and 90% isodose curves in all the three sets of CT images were found to be similar. Depths of 80%, 70%, 60%, 50%, and 40% isodose lines in SPS phantom images were found to be equivalent to that in chest images, while it was least in SP34 phantom images. Variations in doses calculated at 6, 10, and 18 cm depths on TPS and measured on LA were found to be 0.36%, 1.65%, and 2.23%, respectively, in case of SPS phantom, while 0.24%, 0.90%, and 0.93%, respectively, in case of SP34 slab phantom. SPS phantom seemed equivalent to the chest level of human body. Dosimetric results of this study indicate that patient-specific quality assurance can be done using chest phantom mimicking thoracic region of human body, which has been fabricated using polystyrene and pinewood.

  20. Phantom limb pain: a case of maladaptive CNS plasticity?

    Science.gov (United States)

    Flor, Herta; Nikolajsen, Lone; Staehelin Jensen, Troels

    2006-11-01

    Phantom pain refers to pain in a body part that has been amputated or deafferented. It has often been viewed as a type of mental disorder or has been assumed to stem from pathological alterations in the region of the amputation stump. In the past decade, evidence has accumulated that phantom pain might be a phenomenon of the CNS that is related to plastic changes at several levels of the neuraxis and especially the cortex. Here, we discuss the evidence for putative pathophysiological mechanisms with an emphasis on central, and in particular cortical, changes. We cite both animal and human studies and derive suggestions for innovative interventions aimed at alleviating phantom pain.

  1. Efficacy of progressive muscle relaxation, mental imagery, and phantom exercise training on phantom limb: a randomized controlled trial.

    Science.gov (United States)

    Brunelli, Stefano; Morone, Giovanni; Iosa, Marco; Ciotti, Cristina; De Giorgi, Roberto; Foti, Calogero; Traballesi, Marco

    2015-02-01

    To evaluate the reduction in phantom pain and sensation with combined training of progressive muscle relaxation, mental imagery, and phantom exercises. Randomized controlled prospective trial with 2 parallel groups. Amputee unit of a rehabilitation hospital. Subjects with unilateral lower limb amputation (N=51) with phantom limb pain (PLP) and/or phantom limb sensation (PLS). The experimental group performed combined training of progressive muscle relaxation, mental imagery, and phantom exercises 2 times/wk for 4 weeks, whereas the control group had the same amount of physical therapy dedicated to the residual limb. No pharmacological intervention was initiated during the trial period. The Prosthesis Evaluation Questionnaire and the Brief Pain Inventory were used to evaluate changes over time in different aspects (intensity, rate, duration, and bother) of PLS and PLP. Blind evaluations were performed before and after treatment and after 1-month follow-up. The experimental group showed a significant decrease over time in all the Prosthesis Evaluation Questionnaire domains (in terms of both PLS and PLP; Pprogressive muscle relaxation, mental imagery, and modified phantom exercises should be taken into account as a valuable technique to reduce phantom limb pain and sensation. Copyright © 2015 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  2. Versatile Hydrogen-Hydrogen Bond with a Difference

    Indian Academy of Sciences (India)

    Home; Journals; Resonance – Journal of Science Education; Volume 1; Issue 6. Versatile Hydrogen-Hydrogen Bond with a Difference. A G Samuelson. Research News Volume 1 Issue 6 June 1996 pp 87-89. Fulltext. Click here to view fulltext PDF. Permanent link: http://www.ias.ac.in/article/fulltext/reso/001/06/0087-0089 ...

  3. Flexible macrocycles as versatile supports for catalytically active metal clusters

    Energy Technology Data Exchange (ETDEWEB)

    Ryan, JD; Gagnon, KJ; Teat, SJ; McIntosh, RD

    2016-02-12

    Here we present three structurally diverse clusters stabilised by the same macrocyclic polyphenol; t-butylcalix[8]arene. This work demonstrates the range of conformations the flexible ligand is capable of adopting, highlighting its versatility in metal coordination. In addition, a Ti complex displays activity for the ring-opening polymerisation of lactide

  4. A versatile route to benzodiazocine and spiropyran derivatives ...

    Indian Academy of Sciences (India)

    125, No. 3, May 2013, pp. 517–524. c Indian Academy of Sciences. A versatile route to benzodiazocine and spiropyran derivatives through chalcones. JOHNSON GEORGEa, SAURABH SINGHa,. RAHUL JOSHIa and RAMCHAND T PARDASANIb,∗. aDepartment of Chemistry, University of Rajasthan, Jaipur 302 055, India.

  5. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile ...

    African Journals Online (AJOL)

    A Versatile Alternative when Reverse Sural Artery Flap is. Not Feasible. Samuel A. Ademola, Afieharo I. Michael, Femi .... flaps that were raised in the patient and the logistics of limb positioning after application of external fixators for bone ... Financial support and sponsorship. Nil. Conflicts of interest. There are no conflicts of ...

  6. Soybean ( Glycine max ) as a versatile biocatalyst for organic ...

    African Journals Online (AJOL)

    Soybean ( Glycine max ) as a versatile biocatalyst for organic synthesis. ... Most of the obtained alcohols have commercial value as cosmetic fragrances. Although, the enzymes present in soybean (reductase/lipase) has not been defined, the reaction is an important route for the preparation of pure alcohols and carboxylic ...

  7. Propeller Flap for Complex Distal Leg Reconstruction: A Versatile ...

    African Journals Online (AJOL)

    Reverse sural artery fasciocutaneous flap has become a workhorse for the reconstruction of distal leg soft ... A Versatile Alternative when Reverse Sural Artery Flap is. Not Feasible. Samuel A. Ademola, Afieharo I. .... flaps that were raised in the patient and the logistics of limb positioning after application of external fixators ...

  8. Versatile Desktop Experiment Module (DEMo) on Heat Transfer

    Science.gov (United States)

    Minerick, Adrienne R.

    2010-01-01

    This paper outlines a new Desktop Experiment Module (DEMo) engineered for a chemical engineering junior-level Heat Transfer course. This new DEMo learning tool is versatile, fairly inexpensive, and portable such that it can be positioned on student desks throughout a classroom. The DEMo system can illustrate conduction of various materials,…

  9. Versatile Supramolecular Gene Vector Based on Host-Guest Interaction

    NARCIS (Netherlands)

    Liu, Jia; Hennink, Wim E.; Van Steenbergen, Mies J.; Zhuo, Renxi; Jiang, Xulin

    2016-01-01

    It is a great challenge to arrange multiple functional components into one gene vector system to overcome the extra- and intracellular obstacles for gene therapy. In this study, we developed a supramolecular approach for constructing a versatile gene delivery system composed of adamantyl-terminated

  10. Methods for characterizing convective cryoprobe heat transfer in ultrasound gel phantoms.

    Science.gov (United States)

    Etheridge, Michael L; Choi, Jeunghwan; Ramadhyani, Satish; Bischof, John C

    2013-02-01

    , multiprobe freezing geometries. Accurately characterizing cryoprobe behavior in phantoms requires detailed knowledge of the freezing medium's properties throughout the range of expected temperatures and an appropriate description of the heat transfer across the probe's exchange surfaces. Here we demonstrate that convective exchange boundary conditions provide an accurate and versatile description of heat transfer from cryoprobes, offering potential advantages over the traditional constant surface heat flux and constant surface temperature descriptions. In addition, although this study was conducted on Joule-Thomson type cryoprobes, the general methodologies should extend to any probe that is based on convective exchange with a cryogenic fluid.

  11. Cosmological perturbations on the Phantom brane

    CERN Document Server

    Bag, Satadru; Shtanov, Yuri; Sahni, Varun

    2016-01-01

    We obtain a closed system of equations for scalar perturbations in a multi-component braneworld. Our braneworld possesses a phantom-like equation of state at late times, $w_{\\rm eff} < -1$, but no big-rip future singularity. In addition to matter and radiation, the braneworld possesses a new effective degree of freedom - the 'Weyl fluid' or 'dark radiation'. Setting initial conditions on super-Hubble spatial scales at the epoch of radiation domination, we evolve perturbations of radiation, pressureless matter and the Weyl fluid until the present epoch. We observe a gradual decrease in the amplitude of the Weyl-fluid perturbations after Hubble-radius crossing, which results in a negligible effect of the Weyl fluid on the evolution of matter perturbations on spatial scales relevant for structure formation. Consequently, the quasi-static approximation of Koyama and Maartens provides a good fit to the exact results during the matter-dominated epoch. We find that the late-time growth of density perturbations on...

  12. Dynamic eye phantom for retinal oximetry measurements

    Science.gov (United States)

    Lemaillet, Paul; Ramella-Roman, Jessica C.

    2009-11-01

    Measurements of oxygen saturation and flow in the retina can yield information about eye health and the onset of eye pathologies such as diabetic retinopathy. Recently, we developed a multiaperture camera that uses the division of the retinal image into several wavelength-sensitive subimages to compute retinal oxygen saturation. The calibration of such instruments is particularly difficult due to the layered structure of the eye and the lack of alternative measurement techniques. For this purpose, we realize an in vitro model of the human eye composed of a lens, the retina vessel, and three layers: the choroid, the retinal pigmented epithelium, and the sclera. The retinal vessel is modeled with a microtube connected to a micropump and a hemoglobin reservoir in a closed circulatory system. Hemoglobin oxygenation in the vessel could be altered using a reversible fuel cell. The sclera is represented by a Spectralon slab. The optical properties of the other layers are mimicked using titanium dioxide as a scatterer, ink as an absorber, and epoxy as a supporting structure. The optical thickness of each layer of the eye phantom is matched to each respective eye layer.

  13. Bioassay Phantoms Using Medical Images and Computer Aided Manufacturing

    Energy Technology Data Exchange (ETDEWEB)

    Dr. X. Geroge Xu

    2011-01-28

    A radiation bioassay program relies on a set of standard human phantoms to calibrate and assess radioactivity levels inside a human body for radiation protection and nuclear medicine imaging purposes. However, the methodologies in the development and application of anthropomorphic phantoms, both physical and computational, had mostly remained the same for the past 40 years. We herein propose a 3-year research project to develop medical image-based physical and computational phantoms specifically for radiation bioassay applications involving internally deposited radionuclides. The broad, long-term objective of this research was to set the foundation for a systematic paradigm shift away from the anatomically crude phantoms in existence today to realistic and ultimately individual-specific bioassay methodologies. This long-term objective is expected to impact all areas of radiation bioassay involving nuclear power plants, U.S. DOE laboratories, and nuclear medicine clinics.

  14. A solid tissue phantom for photon migration studies

    Energy Technology Data Exchange (ETDEWEB)

    Cubeddu, Rinaldo; Pifferi, Antonio; Taroni, Paola; Torricelli, Alessandro; Valentini, Gianluca [CEQSE-CNR and Dipartimento di Fisica, Politecnico di Milano, Piazza L da Vinci 32, 20133 Milano (Italy)

    1997-10-01

    A solid tissue phantom made of agar, Intralipid and black ink is described and characterized. The preparation procedure is fast and easily implemented with standard laboratory equipment. An instrumentation for time-resolved transmittance measurements was used to determine the optical properties of the phantom. The absorption and the reduced scattering coefficients are linear with the ink and Intralipid concentrations, respectively. A systematic decrease of the reduced scattering coefficient dependent on the agar content is observed, but can easily be managed. The phantom is highly homogeneous and shows good repeatability among different preparations. Moreover, agar inclusions can be easily embedded in either solid or liquid matrixes, and no artefacts are caused by the solid - solid or solid - liquid interfaces. This allows one to produce reliable and realistic inhomogeneous phantoms with known optical properties, particularly interesting for studies on optical imaging through turbid media. (author)

  15. Prototype phantoms for characterization of ultralow field magnetic resonance imaging.

    Science.gov (United States)

    Boss, Michael A; Mates, John A B; Busch, Sarah E; SanGiorgio, Paul; Russek, Stephen E; Buckenmaier, Kai; Irwin, Kent D; Cho, Hsiao-Mei; Hilton, Gene C; Clarke, John

    2014-12-01

    Prototype phantoms were designed, constructed, and characterized for the purpose of calibrating ultralow field magnetic resonance imaging (ULF MRI) systems. The phantoms were designed to measure spatial resolution and to quantify sensitivity to systematic variation of proton density and relaxation time, T1 . The phantoms were characterized first with conventional magnetic resonance scanners at 1.5 and 3 T, and subsequently with a prototype ULF MRI scanner between 107 and 128 μT . The ULF system demonstrated a 2-mm spatial resolution and, using T1 measurements, distinguished aqueous solutions of MnCl2 differing by 20 μM  [Mn(2+) ]. The prototype phantoms proved well-matched to ULF MRI applications, and allowed direct comparison of the performance of ULF and clinical systems. © 2013 Wiley Periodicals, Inc.

  16. Phantom dark ghost in Einstein-Cartan gravity

    Science.gov (United States)

    Chang, Yu-Chiao; Bouhmadi-López, Mariam; Chen, Pisin

    2017-05-01

    A class of dynamical dark energy models is constructed through an extended version of fermion fields corresponding to phantom dark ghost spinors, which are spin 1/2 with mass dimension 1. We find that if these spinors interact with torsion fields in a homogeneous and isotropic universe, then it does not imply any future dark energy singularity or any abrupt event, though the fermion has a negative kinetic energy. In fact, the equation of state of this dark energy model will asymptotically approach the value w=-1 from above without crossing the phantom divide and inducing therefore a de Sitter state. Consequently, we expect the model to be stable because no real phantom fields will be created. At late time, the torsion fields will vanish as the corresponding phantom dark ghost spinors dilute. As would be expected, intuitively, this result is unaffected by the presence of cold dark matter although the proof is not as straightforward as in general relativity.

  17. Suggested guidelines for treatment of phantom limb pain.

    Science.gov (United States)

    Sherman, R A; Tippens, J K

    1982-12-01

    Eighty to ninety percent of amputees have been shown to suffer significant amounts of phantom limb pain in contrast to the widely accepted level of about 5%. Surveys of the literature, of physicians actively treating phantom pain, and of over 3,000 American veteran amputees have shown that most of the usual treatments are not efficacious when followups of a year or more are done. A diagnostic and therapeutic schemata is presented, which incorporates the above surveys, research, and clinical experience into a unified approach optimizing the few treatments showing a reasonable hope of long term success. Every effort is made to identify the source of pain being referred into the phantom. Stump, back, prosthetic, and other physical problems are corrected prior to initiation of other treatments, including EMG or temperature feedback from the stump, sympathetic system alteration, modulation of anxiety and depression, TENS, and ultrasound. Key indexing terms: phantom pain, treatment, amputees, referred pain. Copyright 2013, SLACK Incorporated.

  18. Fabrication and characterization of biological tissue phantoms with embedded nanoparticles

    Science.gov (United States)

    Skaptsov, A. A.; Ustalkov, S. O.; Mohammed, A. H. M.; Savenko, O. A.; Novikova, A. S.; Kozlova, E. A.; Kochubey, V. I.

    2017-11-01

    Phantoms are imitations of biological tissue, which are used for modelling of the light propagation in biological tissues. Carrying out any biophysical experiments requires an indispensable constancy of the initial experiment conditions. The use of solid undegradable phantoms is the basis to obtain reliable reproducible experimental results. The fabrication of biological tissues phantoms containing high absorbance or fluorescence nanoparticles and corresponding to specific mechanical, optical properties is an actual task. This work describes development, fabrication and characterization of such solid tissue phantoms with embedded CdSe/ZnS quantum dots, gold and upconversion nanoparticles. Luminescence of samples with CdSe/ZnS quantum dots and upconversion nanoparticles were recorded. A sample of gold nanorods was analyzed using thermal gravimetric analysis. It can be concluded that the samples are well suited for experiments on laser thermolysis.

  19. Phantom dark ghost in Einstein-Cartan gravity

    Energy Technology Data Exchange (ETDEWEB)

    Chang, Yu-Chiao [National Taiwan University, Department of Physics, Taipei (China); National Taiwan University, LeCosPA, Taipei (China); Bouhmadi-Lopez, Mariam [University of the Basque Country UPV/EHU, Department of Theoretical Physics, P.O. Box 644, Bilbao (Spain); Basque Foundation for Science, IKERBASQUE, Bilbao (Spain); Chen, Pisin [National Taiwan University, Department of Physics, Taipei (China); National Taiwan University, LeCosPA, Taipei (China); National Taiwan University, Graduate Institute of Astrophysics, Taipei (China); SLAC National Accelerator Laboratory, Stanford University, Kavli Institute for Particle Astrophysics and Cosmology, Stanford, CA (United States)

    2017-05-15

    A class of dynamical dark energy models is constructed through an extended version of fermion fields corresponding to phantom dark ghost spinors, which are spin 1/2 with mass dimension 1. We find that if these spinors interact with torsion fields in a homogeneous and isotropic universe, then it does not imply any future dark energy singularity or any abrupt event, though the fermion has a negative kinetic energy. In fact, the equation of state of this dark energy model will asymptotically approach the value w = -1 from above without crossing the phantom divide and inducing therefore a de Sitter state. Consequently, we expect the model to be stable because no real phantom fields will be created. At late time, the torsion fields will vanish as the corresponding phantom dark ghost spinors dilute. As would be expected, intuitively, this result is unaffected by the presence of cold dark matter although the proof is not as straightforward as in general relativity. (orig.)

  20. Motor cortex changes after amputation are modulated by phantom limb motor control rather than pain

    DEFF Research Database (Denmark)

    Raffin, Estelle E.; Pascal, Giraux,; Karen, Reilly,

    retains a residual M1-c activity when amputees perform phantom limb movements (4-5). Except a correlation between phantom limb pain and M1-c expansion of the face (2-3), the relationship between the ability to voluntary move the phantom hand, the level of phantom limb pain, the degree of M1-c...

  1. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    OpenAIRE

    Camerin Hahn; Sima Noghanian

    2012-01-01

    As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectri...

  2. Dedicated phantom materials for spectral radiography and CT.

    Science.gov (United States)

    Shikhaliev, Polad M

    2012-03-21

    As x-ray imaging technology moves from conventional radiography and computed tomography (CT) to spectral radiography and CT, dedicated phantom materials are needed for spectral imaging. The spectral phantom materials should accurately represent the energy-dependent mass-attenuation coefficients of different types of tissues. Although tissue-equivalent phantom materials were previously developed for CT and radiation therapy applications, these materials are suboptimal for spectral radiography and CT; they are not compatible with contrast agents, do not represent many of the tissue types and do not provide accurate values of attenuation characteristics of tissue. This work provides theoretical framework and a practical method for developing tissue-equivalent spectral phantom materials with a required set of parameters. The samples of the tissue-equivalent spectral phantom materials were developed, tested and characterized. The spectral phantom materials were mixed with iodine, gold and calcium contrast agents and evaluated. The materials were characterized by CT imaging and x-ray transmission experiments. The fabricated materials had nearly identical densities, mass attenuation coefficients, effective atomic numbers and electron densities as compared to corresponding tissue materials presented in the ICRU-44 report. The experimental results have shown good volume uniformity and inter-sample uniformity (repeatability of sample fabrication) of the fabricated materials. The spectral phantom materials were fabricated under laboratory conditions from readily available and inexpensive components. It was concluded that the presented theoretical framework and fabrication method of dedicated spectral phantom materials could be useful for researchers and developers working in the new area of spectral radiography and CT. Independently, the results could also be useful for other applications, such as radiation therapy. © 2012 Institute of Physics and Engineering in Medicine

  3. Hubungan Phantom Vibration Syndrome Terhadap Sleep Disorder dan Kondisi Stress

    OpenAIRE

    Ajeng Yeni Setianingrum

    2017-01-01

    Phantom vibration syndrome is a condition where a person would feel the sensation of vibration of a cell phone as if there were incoming notification but the fact is not. This research investigated the relationship between phantom vibration syndromes, sleep disorder and stress condition. Questionnaires were distributed to 120 participants with age range 18 to 23 years old. Data of participants showed that all of participants using a smart mobile phone and 24% of them have more than one cell p...

  4. Caracterización de Phantoms por ultrasonidos

    OpenAIRE

    ORTÍ ANGLÉS, CARLOS

    2012-01-01

    El principal objetivo es el desarrollo de sistemas ultrasónicos que permitan medir con precisión distribuciones de los principales parámetros acústicos que caracterizan el comportamiento de los "Tejidos equivalentes" (Phantoms), empleados en laboratorio con el fin de identificar entre tejidos sano y enfermo mediante los ultrasonidos Ortí Anglés, C. (2012). Caracterización de Phantoms por ultrasonidos. http://hdl.handle.net/10251/17787. Archivo delegado

  5. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry

    Science.gov (United States)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-04-01

    Hybrid computational phantoms combine voxel-based and simplified equation-based modelling approaches to provide unique advantages and more realism for the construction of anthropomorphic models. In this work, a methodology and C++ code are developed to generate hybrid computational phantoms covering statistical distributions of body morphometry in the paediatric population. The paediatric phantoms of the Virtual Population Series (IT’IS Foundation, Switzerland) were modified to match target anthropometric parameters, including body mass, body length, standing height and sitting height/stature ratio, determined from reference databases of the National Centre for Health Statistics and the National Health and Nutrition Examination Survey. The phantoms were selected as representative anchor phantoms for the newborn, 1, 2, 5, 10 and 15 years-old children, and were subsequently remodelled to create 1100 female and male phantoms with 10th, 25th, 50th, 75th and 90th body morphometries. Evaluation was performed qualitatively using 3D visualization and quantitatively by analysing internal organ masses. Overall, the newly generated phantoms appear very reasonable and representative of the main characteristics of the paediatric population at various ages and for different genders, body sizes and sitting stature ratios. The mass of internal organs increases with height and body mass. The comparison of organ masses of the heart, kidney, liver, lung and spleen with published autopsy and ICRP reference data for children demonstrated that they follow the same trend when correlated with age. The constructed hybrid computational phantom library opens up the prospect of comprehensive radiation dosimetry calculations and risk assessment for the paediatric population of different age groups and diverse anthropometric parameters.

  6. Prevalent hallucinations during medical internships: phantom vibration and ringing syndromes.

    Directory of Open Access Journals (Sweden)

    Yu-Hsuan Lin

    Full Text Available BACKGROUND: Phantom vibration syndrome is a type of hallucination reported among mobile phone users in the general population. Another similar perception, phantom ringing syndrome, has not been previously described in the medical literature. METHODS: A prospective longitudinal study of 74 medical interns (46 males, 28 females; mean age, 24.8±1.2 years was conducted using repeated investigations of the prevalence and associated factors of phantom vibration and ringing. The accompanying symptoms of anxiety and depression were evaluated with the Beck Anxiety and Depression Inventories before the internship began, and again at the third, sixth, and twelfth internship months, and two weeks after the internship ended. RESULTS: The baseline prevalence of phantom vibration was 78.1%, which increased to 95.9% and 93.2% in the third and sixth internship months. The prevalence returned to 80.8% at the twelfth month and decreased to 50.0% 2 weeks after the internship ended. The baseline prevalence of phantom ringing was 27.4%, which increased to 84.9%, 87.7%, and 86.3% in the third, sixth, and twelfth internship months, respectively. This returned to 54.2% two weeks after the internship ended. The anxiety and depression scores also increased during the internship, and returned to baseline two weeks after the internship. There was no significant correlation between phantom vibration/ringing and symptoms of anxiety or depression. The incidence of both phantom vibration and ringing syndromes significantly increased during the internship, and subsequent recovery. CONCLUSION: This study suggests that phantom vibration and ringing might be entities that are independent of anxiety or depression during evaluation of stress-associated experiences during medical internships.

  7. [Psychotherapies for the Treatment of Phantom Limb Pain].

    Science.gov (United States)

    Cárdenas, Katherine; Aranda, Mariana

    The phantom limb pain has been described as a condition in which patients experience a feeling of itching, spasm or pain in a limb or body part that has been previously amputated. Such pain can be induced by a conflict between the representation of the visual and proprioceptive feedback of the previously healthy limb. The phantom limb pain occurs in at least 42 to 90% of amputees. Regular drug treatment of phantom limb pain is almost never effective. A systematic review of the literature was conducted in Medline and Cochrane using the MESH terms "phantom limb pain" and "psychotherapy", published in the last 10 years, in English and Spanish, finding 49 items. After reviewing the abstracts, 25 articles were excluded for not being related to the objective of the research. Additionally cross references of included articles and literature were reviewed. To describe the psychotherapies used in the management of phantom limb pain, their effectiveness and clinical application reported in the literature. The mechanisms underlying phantom limb pain were initially explained, as were the published studies on the usefulness of some psychotherapies such as mirror visual feedback and immersive virtual reality, visual imagery, desensitization and reprocessing eye movements and hypnosis. The phantom limb pain is a complex syndrome that requires pharmacological and psychotherapeutic intervention. The psychotherapies that have been used the most as adjuvants in the treatment of phantom limb pain are mirror visual feedback, desensitization and reprocessing eye movements, imagery and hypnosis. Studies with more representative samples, specifically randomized trials are required. Copyright © 2016 Asociación Colombiana de Psiquiatría. Publicado por Elsevier España. All rights reserved.

  8. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    Directory of Open Access Journals (Sweden)

    Camerin Hahn

    2012-01-01

    Full Text Available As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectric properties. We propose a systematic approach in designing phantoms that not only have dielectric properties close to breast tissues but also can be easily shaped to realistic physical models. The approach is based on regression model to match phantom's dielectric properties with the breast tissue dielectric properties found in Lazebnik et al. (2007. However, the methodology proposed here can be used to create phantoms for any tissue type as long as ex vivo, in vitro, or in vivo tissue dielectric properties are measured and available. Therefore, using this method, accurate benchmarking phantoms for testing emerging microwave imaging algorithms can be developed.

  9. Heterogeneous Breast Phantom Development for Microwave Imaging Using Regression Models

    Science.gov (United States)

    Hahn, Camerin; Noghanian, Sima

    2012-01-01

    As new algorithms for microwave imaging emerge, it is important to have standard accurate benchmarking tests. Currently, most researchers use homogeneous phantoms for testing new algorithms. These simple structures lack the heterogeneity of the dielectric properties of human tissue and are inadequate for testing these algorithms for medical imaging. To adequately test breast microwave imaging algorithms, the phantom has to resemble different breast tissues physically and in terms of dielectric properties. We propose a systematic approach in designing phantoms that not only have dielectric properties close to breast tissues but also can be easily shaped to realistic physical models. The approach is based on regression model to match phantom's dielectric properties with the breast tissue dielectric properties found in Lazebnik et al. (2007). However, the methodology proposed here can be used to create phantoms for any tissue type as long as ex vivo, in vitro, or in vivo tissue dielectric properties are measured and available. Therefore, using this method, accurate benchmarking phantoms for testing emerging microwave imaging algorithms can be developed. PMID:22550473

  10. Two-layer heterogeneous breast phantom for photoacoustic imaging

    Science.gov (United States)

    Jia, Congxian; Vogt, William C.; Wear, Keith A.; Pfefer, T. Joshua; Garra, Brian S.

    2017-10-01

    Photoacoustic tomography (PAT) is emerging as a potentially important aid for breast cancer detection. Well-validated tissue-simulating phantoms are needed for objective, quantitative, and physically realistic testing for system development. Prior reported PAT phantoms with homogenous structures do not incorporate the irregular layered structure of breast tissue. To assess the impact of this simplification, we design and construct two-layer breast phantoms incorporating vessel-simulating inclusions and realistic undulations at the fat/fibroglandular tissue interface. The phantoms are composed of custom poly(vinyl chloride) plastisol formulations mimicking the acoustic properties of two breast tissue types and tissue-relevant similar optical properties. Resulting PAT images demonstrate that in tissue with acoustic heterogeneity, lateral size of imaging targets is sensitive to the choice of sound speed in image reconstruction. The undulating boundary can further degrade a target's lateral size due to sound speed variation in tissue and refraction of sound waves at the interface. The extent of this degradation is also influenced by the geometric relationship between an absorber and the boundary. Results indicate that homogeneous phantom matrixes may underestimate the degradation of PAT image quality in breast tissue, whereas heterogeneous phantoms can provide more realistic testing through improved reproduction of spatial variations in physical properties.

  11. A software assistant for the design of realistic software phantoms

    Science.gov (United States)

    Rexilius, Jan; Konrad, Olaf; Peitgen, Heinz-Otto

    2008-03-01

    Segmentation and quantification of medical image data are difficult problems in image analysis. Especially, an accurate and robust assessment of quantitative parameters is a key issue in many fields, and can have a direct impact on diagnosis and treatment planning. To this end, physical and software phantom data sets have become an integral tool during the design, implementation, and optimization of new algorithms. Unfortunately, a common research resource has not been established until now for many applications. In this work we propose a software assistant for the development of realistic software phantoms. Our aim is an easy-to-use tool with an intuitive user interface. Furthermore, we provide a software for researchers including a common basis of reference data, which facilitates a standardized and objective validation of performance and limitations of own developments, as well as the comparison of different methods. The fundamental phantom design focuses on objects that can be incorporated into a given background. This can either be a homogeneous artificial background, or a volunteer or patient data set. For each phantom the exact ground truth of the investigated object is available, which provides us with an excellent tool for the generation of realistic data sets. Several experiments are carried out for a number of different applications including software phantoms of small, hyperintense brain lesions, as well as software phantoms of liver metastases.

  12. Liver phantom for quality control and training in nuclear medicine

    Science.gov (United States)

    Lima Ferreira, Fernanda Carla; Souza, Divanizia do Nascimento

    2011-10-01

    In nuclear medicine, liver scintigraphy aims to verify organ function based on the radionuclide concentration in the liver and bile flow and is also used to detect tumors. Therefore it is necessary to perform quality control tests in the gamma camera before running the exam to prevent false results. Quality control tests of the gamma camera should thus be performed before running the exam to prevent false results. Such tests generally use radioactive material inside phantoms for evaluation of gamma camera parameters in quality control procedures. Phantoms can also be useful for training doctors and technicians in nuclear medicine procedures. The phantom proposed here has artifacts that simulate nodules; it may take on different quantities, locations and sizes and it may also be mounted without the introduction of nodules. Thus, its images may show hot or cold nodules or no nodules. The phantom consists of acrylic plates hollowed out in the centre, with the geometry of an adult liver. Images for analyses of simulated liver scintigraphy were obtained with the detector device at 5 cm from the anterior surface of the phantom. These simulations showed that this object is suitable for quality control in nuclear medicine because it was possible to visualize artifacts larger than 7.9 mm using a 256×256 matrix and 1000 kcpm. The phantom constructed in this work will also be useful for training practitioners and technicians in order to prevent patients from repeat testing caused by error during examinations.

  13. Divergence-free smoothing for MRV data on stenosed carotid artery phantom flows

    Science.gov (United States)

    Im, Chaehyuk; Ko, Seungbin; Song, Simon

    2017-11-01

    Magnetic Resonance Velocimetry (MRV) is a versatile technique for measuring flow velocity using an MRI machine. It is frequently used for visualization and analysis of blood flows. However, it is difficult to accurately estimate hemodynamics parameters like wall shear stress (WSS) and oscillatory shear index (OSI) due to its low spatial resolution and low signal-to-noise ratio. We suggest a divergence-free smoothing (DFS) method to correct the erroneous velocity vectors obtained with MRV and improve the estimation accuracy of those parameters. Unlike previous studies on DFS for a wall-free flow, we developed a house code to apply a DFS method to a wall-bounded flow. A Hagen-Poiseuille flow and stenosed carotid artery phantom flows were measured with MRV. Each of them was analyzed for validation of the DFS code and confirmation on the accuracy improvement of hemodynamic parameters. We will discuss the effects of DFS on the improvement of the estimation accuracy of velocity vectors, WSS, OSI and etc in detail This work was supported by the National Research Foundation of Korea(NRF) Grant funded by the Korea government(MSIP) (No. 2016R1A2B3009541).

  14. egs_brachy: a versatile and fast Monte Carlo code for brachytherapy

    Science.gov (United States)

    Chamberland, Marc J. P.; Taylor, Randle E. P.; Rogers, D. W. O.; Thomson, Rowan M.

    2016-12-01

    egs_brachy is a versatile and fast Monte Carlo (MC) code for brachytherapy applications. It is based on the EGSnrc code system, enabling simulation of photons and electrons. Complex geometries are modelled using the EGSnrc C++ class library and egs_brachy includes a library of geometry models for many brachytherapy sources, in addition to eye plaques and applicators. Several simulation efficiency enhancing features are implemented in the code. egs_brachy is benchmarked by comparing TG-43 source parameters of three source models to previously published values. 3D dose distributions calculated with egs_brachy are also compared to ones obtained with the BrachyDose code. Well-defined simulations are used to characterize the effectiveness of many efficiency improving techniques, both as an indication of the usefulness of each technique and to find optimal strategies. Efficiencies and calculation times are characterized through single source simulations and simulations of idealized and typical treatments using various efficiency improving techniques. In general, egs_brachy shows agreement within uncertainties with previously published TG-43 source parameter values. 3D dose distributions from egs_brachy and BrachyDose agree at the sub-percent level. Efficiencies vary with radionuclide and source type, number of sources, phantom media, and voxel size. The combined effects of efficiency-improving techniques in egs_brachy lead to short calculation times: simulations approximating prostate and breast permanent implant (both with (2 mm)3 voxels) and eye plaque (with (1 mm)3 voxels) treatments take between 13 and 39 s, on a single 2.5 GHz Intel Xeon E5-2680 v3 processor core, to achieve 2% average statistical uncertainty on doses within the PTV. egs_brachy will be released as free and open source software to the research community.

  15. Motorized fusion guided prostate biopsy: phantom study

    Science.gov (United States)

    Seifabadi, Reza; Xu, Sheng; Aalamifar, Fereshteh; Pinto, Peter; Wood, Bradford J.

    2017-03-01

    Purpose: Fusion of Magnetic Resonance Imaging (MRI) with intraoperative real-time Ultrasound (US) during prostate biopsy has significantly improved the sensitivity of transrectal ultrasound (TRUS) guided cancer detection. Currently, sweeping of the TRUS probe to build a 3D volume as part of the fusion process and the TRUS probe manipulation for needle guidance are both done manually. A motorized, joystick controlled, probe holder was custom fabricated that can potentially reduce inter-operator variability, provide standardization of needle placement, improve repeatability and uniformity of needle placement, which may have impacts upon the learning curve after clinical deployment of this emerging approach. Method: a 2DOF motorized probe holder was designed to provide translation and rotation of a triplane TRUS end firing probe for prostate biopsy. The probe holder was joystick controlled and can assist manipulation of the probe during needle insertion as well as in acquiring a smoother US 2D to 3D sweep in which the 3D US volume for fusion is built. A commercial MRI-US fusion platform was used. Three targets were specified on MR image of a commercial prostate phantom. After performing the registration, two operators performed targeting, once manually and once with the assistance of the motorized probe holder. They repeated these tasks 5 times resulting in a total of 30 targeting events. Time of completion and mechanical error i.e. distance of the target from the needle trajectory in the software user interface were measured. Repeatability in reaching a given target in a systematic and consistent way was measured using a scatter plot showing all targets in the US coordinate system. Pearson product-moment correlation coefficient (PPMCC) was used to demonstrate the probe steadiness during targeting. Results: the completion time was 25+/-17 sec, 25+/-24 sec, and 27+/-15 sec for free hand and 24+/-10 sec, 22.5+/-10 sec, and 37+/-10 sec for motorized insertion, for target

  16. Environmental versatility promotes modularity in genome-scale metabolic networks.

    Science.gov (United States)

    Samal, Areejit; Wagner, Andreas; Martin, Olivier C

    2011-08-24

    The ubiquity of modules in biological networks may result from an evolutionary benefit of a modular organization. For instance, modularity may increase the rate of adaptive evolution, because modules can be easily combined into new arrangements that may benefit their carrier. Conversely, modularity may emerge as a by-product of some trait. We here ask whether this last scenario may play a role in genome-scale metabolic networks that need to sustain life in one or more chemical environments. For such networks, we define a network module as a maximal set of reactions that are fully coupled, i.e., whose fluxes can only vary in fixed proportions. This definition overcomes limitations of purely graph based analyses of metabolism by exploiting the functional links between reactions. We call a metabolic network viable in a given chemical environment if it can synthesize all of an organism's biomass compounds from nutrients in this environment. An organism's metabolism is highly versatile if it can sustain life in many different chemical environments. We here ask whether versatility affects the modularity of metabolic networks. Using recently developed techniques to randomly sample large numbers of viable metabolic networks from a vast space of metabolic networks, we use flux balance analysis to study in silico metabolic networks that differ in their versatility. We find that highly versatile networks are also highly modular. They contain more modules and more reactions that are organized into modules. Most or all reactions in a module are associated with the same biochemical pathways. Modules that arise in highly versatile networks generally involve reactions that process nutrients or closely related chemicals. We also observe that the metabolism of E. coli is significantly more modular than even our most versatile networks. Our work shows that modularity in metabolic networks can be a by-product of functional constraints, e.g., the need to sustain life in multiple

  17. Environmental versatility promotes modularity in genome-scale metabolic networks

    Science.gov (United States)

    2011-01-01

    Background The ubiquity of modules in biological networks may result from an evolutionary benefit of a modular organization. For instance, modularity may increase the rate of adaptive evolution, because modules can be easily combined into new arrangements that may benefit their carrier. Conversely, modularity may emerge as a by-product of some trait. We here ask whether this last scenario may play a role in genome-scale metabolic networks that need to sustain life in one or more chemical environments. For such networks, we define a network module as a maximal set of reactions that are fully coupled, i.e., whose fluxes can only vary in fixed proportions. This definition overcomes limitations of purely graph based analyses of metabolism by exploiting the functional links between reactions. We call a metabolic network viable in a given chemical environment if it can synthesize all of an organism's biomass compounds from nutrients in this environment. An organism's metabolism is highly versatile if it can sustain life in many different chemical environments. We here ask whether versatility affects the modularity of metabolic networks. Results Using recently developed techniques to randomly sample large numbers of viable metabolic networks from a vast space of metabolic networks, we use flux balance analysis to study in silico metabolic networks that differ in their versatility. We find that highly versatile networks are also highly modular. They contain more modules and more reactions that are organized into modules. Most or all reactions in a module are associated with the same biochemical pathways. Modules that arise in highly versatile networks generally involve reactions that process nutrients or closely related chemicals. We also observe that the metabolism of E. coli is significantly more modular than even our most versatile networks. Conclusions Our work shows that modularity in metabolic networks can be a by-product of functional constraints, e.g., the need to

  18. Environmental versatility promotes modularity in genome-scale metabolic networks

    Directory of Open Access Journals (Sweden)

    Wagner Andreas

    2011-08-01

    Full Text Available Abstract Background The ubiquity of modules in biological networks may result from an evolutionary benefit of a modular organization. For instance, modularity may increase the rate of adaptive evolution, because modules can be easily combined into new arrangements that may benefit their carrier. Conversely, modularity may emerge as a by-product of some trait. We here ask whether this last scenario may play a role in genome-scale metabolic networks that need to sustain life in one or more chemical environments. For such networks, we define a network module as a maximal set of reactions that are fully coupled, i.e., whose fluxes can only vary in fixed proportions. This definition overcomes limitations of purely graph based analyses of metabolism by exploiting the functional links between reactions. We call a metabolic network viable in a given chemical environment if it can synthesize all of an organism's biomass compounds from nutrients in this environment. An organism's metabolism is highly versatile if it can sustain life in many different chemical environments. We here ask whether versatility affects the modularity of metabolic networks. Results Using recently developed techniques to randomly sample large numbers of viable metabolic networks from a vast space of metabolic networks, we use flux balance analysis to study in silico metabolic networks that differ in their versatility. We find that highly versatile networks are also highly modular. They contain more modules and more reactions that are organized into modules. Most or all reactions in a module are associated with the same biochemical pathways. Modules that arise in highly versatile networks generally involve reactions that process nutrients or closely related chemicals. We also observe that the metabolism of E. coli is significantly more modular than even our most versatile networks. Conclusions Our work shows that modularity in metabolic networks can be a by-product of functional

  19. [Mirror, mirror of the wall: mirror therapy in the treatment of phantom limbs and phantom limb pain].

    Science.gov (United States)

    Casale, Roberto; Furnari, Anna; Lamberti, Raul Coelho; Kouloulas, Efthimios; Hagenberg, Annegret; Mallik, Maryam

    2015-01-01

    Phantom limb and phantom limb pain control are pivotal points in the sequence of intervention to bring the amputee to functional autonomy. The alterations of perception and sensation, the pain of the residual limb and the phantom limb are therefore aspects of amputation that should be taken into account in the "prise en charge" of these patients. Within the more advanced physical therapies to control phantom and phantom limb pain there is the use of mirrors (mirror therapy). This article willfocus on its use and on the possible side effects induced by the lack of patient selection and a conflict of body schema restoration through mirror therapy with concurrent prosthetic training and trauma acceptance. Advice on the need to select patients before treatment decisions, with regard to their psychological as well as clinical profile (including time since amputation and clinical setting), and the need to be aware of the possible adverse effects matching different and somehow conflicting therapeutic approaches, are put forward. Thus a coordinated sequence of diagnostic, prognostic and therapeutic procedures carried out by an interdisciplinary rehabilitation team that works globally on all patients' problems is fundamental in the management of amputees and phantom limb pain. Further studies and the development of a multidisciplinary network to study this and other applications of mirror therapy are needed.

  20. Energy Efficient Resource Allocation for Phantom Cellular Networks

    KAUST Repository

    Abdelhady, Amr

    2016-04-01

    Multi-tier heterogeneous networks have become an essential constituent for next generation cellular networks. Meanwhile, energy efficiency (EE) has been considered a critical design criterion along with the traditional spectral efficiency (SE) metric. In this context, we study power and spectrum allocation for the recently proposed two-tier network architecture known as phantom cellular networks. The optimization framework includes both EE and SE. First, we consider sparsely deployed cells experiencing negligible interference and assume perfect channel state information (CSI). For this setting, we propose an algorithm that finds the SE and EE resource allocation strategies. Then, we compare the performance of both design strategies versus number of users, and phantom cells share of the total available resource units (RUs). We aim to investigate the effect of some system parameters to achieve improved SE performance at a non-significant loss in EE performance, or vice versa. It is found that increasing phantom cells share of RUs decreases the SE performance loss due to EE optimization when compared with the optimized SE performance. Second, we consider the densely deployed phantom cellular networks and model the EE optimization problem having into consideration the inevitable interference and imperfect channel estimation. To this end, we propose three resource allocation strategies aiming at optimizing the EE performance metric of this network. Furthermore, we investigate the effect of changing some of the system parameters on the performance of the proposed strategies, such as phantom cells share of RUs, number of deployed phantom cells within a macro cell coverage, number of pilots and the maximum power available for transmission by the phantom cells BSs. It is found that increasing the number of pilots deteriorates the EE performance of the whole setup, while increasing maximum power available for phantom cells transmissions reduces the EE of the whole setup in a

  1. Versatile module for experiments with focussing neutron guides

    Energy Technology Data Exchange (ETDEWEB)

    Adams, T.; Pfleiderer, C.; Böni, P. [Physik-Department, Technische Universität München, D-85748 Garching (Germany); Brandl, G.; Chacon, A.; Wagner, J. N.; Rahn, M.; Mühlbauer, S.; Georgii, R. [Physik-Department, Technische Universität München, D-85748 Garching (Germany); Heinz Maier-Leibnitz Zentrum, FRM II, Technische Universität München, D-85748 Garching (Germany)

    2014-09-22

    We report the development of a versatile module that permits fast and reliable use of focussing neutron guides under varying scattering angles. A simple procedure for setting up the module and neutron guides is illustrated by typical intensity patterns to highlight operational aspects as well as typical parasitic artefacts. Combining a high-precision alignment table with separate housings for the neutron guides on kinematic mounts, the change-over between neutron guides with different focussing characteristics requires no readjustments of the experimental setup. Exploiting substantial gain factors, we demonstrate the performance of this versatile neutron scattering module in a study of the effects of uniaxial stress on the domain populations in the transverse spin density wave phase of single crystal Cr.

  2. Research and development of a versatile portable speech prosthesis

    Science.gov (United States)

    1981-01-01

    The Versatile Portable Speech Prosthesis (VPSP), a synthetic speech output communication aid for non-speaking people is described. It was intended initially for severely physically limited people with cerebral palsy who are in electric wheelchairs. Hence, it was designed to be placed on a wheelchair and powered from a wheelchair battery. It can easily be separated from the wheelchair. The VPSP is versatile because it is designed to accept any means of single switch, multiple switch, or keyboard control which physically limited people have the ability to use. It is portable because it is mounted on and can go with the electric wheelchair. It is a speech prosthesis, obviously, because it speaks with a synthetic voice for people unable to speak with their own voices. Both hardware and software are described.

  3. WE-D-303-00: Computational Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lewis, John [Duke University Medical Center, Durham, NC (United States); Brigham and Women’s Hospital and Dana-Farber Cancer Institute, Boston, MA (United States)

    2015-06-15

    Modern medical physics deals with complex problems such as 4D radiation therapy and imaging quality optimization. Such problems involve a large number of radiological parameters, and anatomical and physiological breathing patterns. A major challenge is how to develop, test, evaluate and compare various new imaging and treatment techniques, which often involves testing over a large range of radiological parameters as well as varying patient anatomies and motions. It would be extremely challenging, if not impossible, both ethically and practically, to test every combination of parameters and every task on every type of patient under clinical conditions. Computer-based simulation using computational phantoms offers a practical technique with which to evaluate, optimize, and compare imaging technologies and methods. Within simulation, the computerized phantom provides a virtual model of the patient’s anatomy and physiology. Imaging data can be generated from it as if it was a live patient using accurate models of the physics of the imaging and treatment process. With sophisticated simulation algorithms, it is possible to perform virtual experiments entirely on the computer. By serving as virtual patients, computational phantoms hold great promise in solving some of the most complex problems in modern medical physics. In this proposed symposium, we will present the history and recent developments of computational phantom models, share experiences in their application to advanced imaging and radiation applications, and discuss their promises and limitations. Learning Objectives: Understand the need and requirements of computational phantoms in medical physics research Discuss the developments and applications of computational phantoms Know the promises and limitations of computational phantoms in solving complex problems.

  4. CREATION OF FEMALE COMPUTATIONAL PHANTOMS FOR CALIBRATION OF LUNG COUNTERS.

    Science.gov (United States)

    Lombardo, Pasquale Alessandro; Lebacq, Anne Laure; Vanhavere, Filip

    2016-09-01

    Plutonium isotopes are of high concern because they lead to high doses. In case of contamination, the activity burden inside the lungs should be assessed accurately. Many studies showed that the presence of breasts has a substantial influence on lung counting efficiencies. Currently, the calibration of most lung counting systems is done by means of physical phantoms representing only male chests. A set of female computational phantoms has been developed in order to provide gender-specific efficiency calibrations for the (241)Am gamma emission (59.54 keV). The phantoms were created starting from a library of female chest phantoms provided by Institut de radioprotection et de sûreté nucléaire (IRSN) (Farah, J. Amélioration des mesures anthroporadiamétriques personnalisées assistées par calcul Monte Carlo: optimisation des temps de calculs et méthodologie de mesure pour l'établissement de la répartition d'activite. PhD Thesis, 2011). While the IRSN phantoms represent a supine measurement position, the SCK•CEN lung counter set-up requires the persons to be sitting in a chair. Using open-source software, the breast shapes of the original phantoms have been recreated to simulate the drooping of breasts in vertical sitting position. A Monte Carlo approach was chosen for calculating calibration coefficients for female lung counting. The results obtained with MCNPx 2.7 simulations showed a significant decrease in the detection efficiency. For bigger bust and breast sizes, the detection efficiency showed to be up to 10 times lower than the ones measured with the Livermore male torso phantom. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  5. Development of breast phantom for quality assessment of mammographic images

    Energy Technology Data Exchange (ETDEWEB)

    Arvelos, Jeniffer Miranda; Flores, Mabel Bustos; Amaral, Fernando; Rio, Margarita Chevalier del; Mourao, Arnaldo Prata, E-mail: jenifferarvelos00@gmail.com [Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte, MG (Brazil). Centro de Engenharia Biomedica; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Universidad Complutense de Madrid (UCM), Madrid (Spain). Faculdad de Medicina. Departmento de Radiologia

    2017-11-01

    Diagnosis of breast cancer in young women may be impaired by the tissue composition of breast in this age group, as fibroglandular tissue is present in greater amount in young women and it has higher density than fibrous and fatty tissues which predominate in women older than 40 years old. The higher density of breast tissue makes it difficult to identify nodules in two-dimensional techniques, due to the overlapping of dense layers. Breast phantoms are used in evaluation and quality control of clinical images, and therefore, it is important to develop non-homogeneous phantoms that may better simulate a real breast. Grouped microcalcifications are often the earliest changes associated with malignant neoplasm of breast. In this work, a phantom was developed in the form of a compressed breast using acrylic resin blend. The resin blend used to fulfill the interior of the phantom has similar mammographic density to the one in fibroglandular tissue, representing a dense breast. The lesions were made of acrylic resin blend and calcium compounds that might simulate breast abnormalities, representing nodules, macrocalcifications and microcalcifications of different dimensions and densities. They were distributed into the ma-terial representing fibroglandular tissue. The developed phantom has a thickness of 1 cm, and it may be matched with other plates to represent a dense breast of thickness between 5 and 6 cm. The main goal of the project is to evaluate the sensitivity of detection of these calcifications in relation to their density and location in the breast in two-dimensional images generated in mammography equipment. Mammographic images allow the visualization of the changes implemented in the phantom. The developed phantom may be used in evaluation of diagnostic images generated through two-dimensional and three-dimensional images. (author)

  6. Characterization of transverse isotropy in compressed tissue-mimicking phantoms.

    Science.gov (United States)

    Urban, Matthew W; Lopera, Manuela; Aristizabal, Sara; Amador, Carolina; Nenadic, Ivan; Kinnick, Randall R; Weston, Alexander D; Qiang, Bo; Zhang, Xiaoming; Greenleaf, James F

    2015-06-01

    Tissues such as skeletal muscle and kidneys have well-defined structure that affects the measurements of mechanical properties. As an approach to characterize the material properties of these tissues, different groups have assumed that they are transversely isotropic (TI) and measure the shear wave velocity as it varies with angle with respect to the structural architecture of the organ. To refine measurements in these organs, it is desirable to have tissue-mimicking phantoms that exhibit similar anisotropic characteristics. Some approaches involve embedding fibers into a material matrix. However, if a homogeneous solid is under compression due to a static stress, an acoustoelastic effect can manifest that makes the measured wave velocities change with the compression stress. We propose to exploit this characteristic to demonstrate that stressed tissue mimicking phantoms can be characterized as a TI material. We tested six phantoms made with different concentrations of gelatin and agar. Stress was applied by the weight of a water container centered on top of a plate on top of the phantom. A linear array transducer and a V-1 Verasonics system were used to induce and measure shear waves in the phantoms. The shear wave motion was measured using a compound plane wave imaging technique. Autocorrelation was applied to the received in-phase/quadrature data. The shear wave velocity, c, was estimated using a Radon transform method. The transducer was mounted on a rotating stage so measurements were made every 10° over a range of 0° to 360°, where the stress is applied along 0° to 180° direction. The shear moduli were estimated. A TI model was fit to the data and the fractional anisotropy was evaluated. This approach can be used to explore many configurations of transverse isotropy with the same phantom, simply by applying stress to the tissue-mimicking phantom.

  7. Characterization of Transverse Isotropy in Compressed Tissue Mimicking Phantoms

    Science.gov (United States)

    Urban, Matthew W.; Lopera, Manuela; Aristizabal, Sara; Amador, Carolina; Nenadic, Ivan; Kinnick, Randall R.; Weston, Alexander D.; Qiang, Bo; Zhang, Xiaoming; Greenleaf, James F.

    2015-01-01

    Tissues such as skeletal muscle and kidneys have well-defined structure that affects the measurements of mechanical properties. As an approach to characterize the material properties of these tissues, different groups have assumed that they are transversely isotropic (TI) and measure the shear wave velocity as it varies with angle with respect to the structural architecture of the organ. To refine measurements in these organs, it is desirable to have tissue mimicking phantoms that exhibit similar anisotropic characteristics. Some approaches involve embedding fibers into a material matrix. However, if a homogeneous solid is under compression due to a static stress, an acoustoelastic effect can manifest which makes the measured wave velocities change with the compression stress. We propose to exploit this characteristic to demonstrate that stressed tissue mimicking phantoms can be characterized as a TI material. We tested six phantoms made with different concentrations of gelatin and agar. Stress was applied by the weight of a water container centered on top of a plate on top of the phantom. A linear array transducer and a V-1 Verasonics system were used to induce and measure shear waves in the phantoms. The shear wave motion was measured using a compound plane wave imaging technique. Autocorrelation was applied to the received in-phase/quadrature data. The shear wave velocity, c, was estimated using a Radon transform method. The transducer was mounted on a rotating stage so measurements were made every 10° over a range of 0–360°, where the stress is applied along 0–180° direction. The shear moduli were estimated. A TI model was fit to the data and the fractional anisotropy was evaluated. This approach can be used to explore many configurations of transverse isotropy with the same phantom, simply by applying stress to the tissue mimicking phantom. PMID:26067038

  8. Fuzzy classification of phantom parent groups in an animal model

    Directory of Open Access Journals (Sweden)

    Fikse Freddy

    2009-09-01

    Full Text Available Abstract Background Genetic evaluation models often include genetic groups to account for unequal genetic level of animals with unknown parentage. The definition of phantom parent groups usually includes a time component (e.g. years. Combining several time periods to ensure sufficiently large groups may create problems since all phantom parents in a group are considered contemporaries. Methods To avoid the downside of such distinct classification, a fuzzy logic approach is suggested. A phantom parent can be assigned to several genetic groups, with proportions between zero and one that sum to one. Rules were presented for assigning coefficients to the inverse of the relationship matrix for fuzzy-classified genetic groups. This approach was illustrated with simulated data from ten generations of mass selection. Observations and pedigree records were randomly deleted. Phantom parent groups were defined on the basis of gender and generation number. In one scenario, uncertainty about generation of birth was simulated for some animals with unknown parents. In the distinct classification, one of the two possible generations of birth was randomly chosen to assign phantom parents to genetic groups for animals with simulated uncertainty, whereas the phantom parents were assigned to both possible genetic groups in the fuzzy classification. Results The empirical prediction error variance (PEV was somewhat lower for fuzzy-classified genetic groups. The ranking of animals with unknown parents was more correct and less variable across replicates in comparison with distinct genetic groups. In another scenario, each phantom parent was assigned to three groups, one pertaining to its gender, and two pertaining to the first and last generation, with proportion depending on the (true generation of birth. Due to the lower number of groups, the empirical PEV of breeding values was smaller when genetic groups were fuzzy-classified. Conclusion Fuzzy

  9. Electrospun nanofibers as versatile interfaces for efficient gene delivery

    OpenAIRE

    Lee, Slgirim; Jin, Gyuhyung; Jang, Jae-Hyung

    2014-01-01

    The integration of gene delivery technologies with electrospun nanofibers is a versatile strategy to increase the potential of gene therapy as a key platform technology that can be readily utilized for numerous biomedical applications, including cancer therapy, stem cell therapy, and tissue engineering. As a spatial template for gene delivery, electrospun nanofibers possess highly advantageous characteristics, such as their ease of production, their ECM-analogue nature, the broad range of cho...

  10. Connecting leadership and learning: Do versatile learners make connective leaders?

    OpenAIRE

    Robinson, Jill L.

    2016-01-01

    Recent failures in leadership, suggest that creating better-quality leadership development programs is critical. In moving from theory to practice, this paper examined the relationship between learning style and leadership style which may enable us to move away from one-size-fits-all leadership development programs. Utilizing Kolb’s Experiential Learning Model and Connective Leadership theory, approximately 3600 college students were analyzed to discover whether versatility in learning styles...

  11. Connecting Leadership and Learning: Do Versatile Learners make Connective Leaders?

    OpenAIRE

    Jill L. Robinson

    2016-01-01

    Abstract Recent failures in leadership, suggest that creating better-quality leadership development programs is critical. In moving from theory to practice, this paper examined the relationship between learning style and leadership style which may enable us to move away from one-size-fits-all leadership development programs. Utilizing Kolb’s Experiential Learning Model and Connective Leadership theory, approximately 3600 college students were analyzed to discover whether versatility in le...

  12. Versatile composite resins simplifying the practice of restorative dentistry.

    Science.gov (United States)

    Margeas, Robert

    2014-01-01

    After decades of technical development and refinement, composite resins continue to simplify the practice of restorative dentistry, offering clinicians versatility, predictability, and enhanced physical properties. With a wide range of products available today, composite resins are a reliable, conservative, multi-functional restorative material option. As manufacturers strive to improve such properties as compression strength, flexural strength, elastic modulus, coefficient of thermal expansion, water sorption, and wear resistance, several classification systems of composite resins have been developed.

  13. Skin Dosimetry in Breast Teletherapy on a Phantom Anthropomorphic and Anthropometric Phantom

    Energy Technology Data Exchange (ETDEWEB)

    Batista Nogueira, Luciana [Anatomy and Imaging Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Lemos Silva, Hugo Leonardo [Santa Casa Hospital, Belo Horizonte (Brazil); Donato da Silva, Sabrina; Passos Ribeiro Campos, Tarcisio [Nuclear Engineering Department, Federal University of Minas Gerais, Belo Horizonte (Brazil)

    2015-07-01

    This paper addresses the breast teletherapy dosimetry. The goal is to evaluate and compare absorbed doses in equivalent skin tissue, TE-skin, of an anthropomorphic and anthropometric breast phantom submitted to breast radiotherapy. The methodology involved the reproduction of a set of tomographic images of the phantom; the elaboration of conformational radiotherapy planning in the SOMAVISION and CadPlan (TPS) software; and the synthetic breast irradiation by parallel opposed fields in 3D conformal teletherapy at 6 MV linear accelerator Clinac-2100 C from VARIAN with prescribed dose (PD) of 180 cGy to the target volume (PTV), referent to the glandular tissue. Radiochromic films EBT2 were selected as dosimeters. Two independent calibration processes of films with solid water Gammex 457 plates and water filled box were produced. Curves of optical density (OD) versus absorbed dose were produced. Dosimeters were positioned in the external region of the breast phantom in contact with TE-skin, area of 4.0 cm{sup 2} each. The irradiation process was prepared in duplicate to check the reproducibility of the technique. The radiochromic films were scanned and their response in RGB (Red, Green, Blue) analyzed by the ImageJ software. The optical density was obtained and converted to dose based on the calibration curves. Thus, the spatial dose distribution in the skin was reproduced. The absorbed doses measured on the radiochromic films in TE-skin showed values between upper and lower quadrants at 9 o'clock in the range of 54% of PD, between the upper and lower quadrants 3 o'clock in the range of 72% and 6 o'clock at the lower quadrant in the range of 68 % of PD. The values are ±64% (p <0.05) according to the TPS. It is concluded that the depth dose measured in solid water plates or water box reproduce equivalent dose values for both calibration processes of the radiochromic films. It was observed that the skin received doses ranging from 50% to 78% of the

  14. A Combinatorial Auction among Versatile Experts and Amateurs

    Science.gov (United States)

    Ito, Takayuki; Yokoo, Makoto; Matsubara, Shigeo

    Auctions have become an integral part of electronic commerce and a promising field for applying multi-agent technologies. Correctly judging the quality of auctioned goods is often difficult for amateurs, in particular, in Internet auctions. However, experts can correctly judge the quality of goods. In this situation, it is difficult to make experts tell the truth and attain an efficient allocation, since experts have a clear advantage over amateurs and they would not reveal their valuable information without some reward. In our previous work, we have succeeded in developing such auction protocols under the following two cases: (1) the case of a single-unit auction among experts and amateurs, and (2) the case of a combinatorial auction among single-skilled experts and amateurs. In this paper, we focus on versatile experts. Versatile experts have an interest in, and expert knowledge on the qualities of several goods. In the case of versatile experts, there would be several problems, e.g., free riding problems, if we simply extended the previous VCG-style auction protocol. Thus, in this paper, we employ PORF (price-oriented, rationing-free) protocol for designing our new protocol to realize a strategy-proof auction protocol for experts. In the protocol, the dominant strategy for experts is truth-telling. Also, for amateurs, truth-telling is the best response when two or more experts select the dominant strategy. Furthermore, the protocol is false-name-proof.

  15. Connecting Leadership and Learning: Do Versatile Learners make Connective Leaders?

    Directory of Open Access Journals (Sweden)

    Jill L. Robinson

    2016-03-01

    Full Text Available Abstract Recent failures in leadership, suggest that creating better-quality leadership development programs is critical. In moving from theory to practice, this paper examined the relationship between learning style and leadership style which may enable us to move away from one-size-fits-all leadership development programs. Utilizing Kolb’s Experiential Learning Model and Connective Leadership theory, approximately 3600 college students were analyzed to discover whether versatility in learning styles translates into versatility in leadership styles. One group of versatile learners reported using a wider range of leadership styles suggesting that learning flexibility may transfer to leadership flexibility. Surprisingly, learners of all types reported utilizing Power and Intrinsic styles of leadership above all others. Implications for leadership development include considering individual differences when crafting leadership programs, matching learning styles to leader training, and the need to move beyond one set of leadership behaviors to increase flexibility in dealing with complex situations. Using a large sample rarely seen in management studies, this paper makes key contributions to the literature. 

  16. Disentangling motor execution from motor imagery with the phantom limb.

    Science.gov (United States)

    Raffin, Estelle; Mattout, Jérémie; Reilly, Karen T; Giraux, Pascal

    2012-02-01

    Amputees can move their phantom limb at will. These 'movements without movements' have generally been considered as motor imagery rather than motor execution, but amputees can in fact perform both executed and imagined movements with their phantom and they report distinct perceptions during each task. Behavioural evidence for this dual ability comes from the fact that executed movements are associated with stump muscle contractions whereas imagined movements are not, and that phantom executed movements are slower than intact hand executed movements whereas the speed of imagined movements is identical for both hands. Since neither execution nor imagination produces any visible movement, we hypothesized that the perceptual difference between these two motor tasks relies on the activation of distinct cerebral networks. Using functional magnetic resonance imaging and changes in functional connectivity (dynamic causal modelling), we examined the activity associated with imagined and executed movements of the intact and phantom hands of 14 upper-limb amputees. Distinct but partially overlapping cerebral networks were active during both executed and imagined phantom limb movements (both performed at the same speed). A region of interest analysis revealed a 'switch' between execution and imagination; during execution there was more activity in the primary somatosensory cortex, the primary motor cortex and the anterior lobe of the cerebellum, while during imagination there was more activity in the parietal and occipital lobes, and the posterior lobe of the cerebellum. In overlapping areas, task-related differences were detected in the location of activation peaks. The dynamic causal modelling analysis further confirmed the presence of a clear neurophysiological distinction between imagination and execution, as motor imagery and motor execution had opposite effects on the supplementary motor area-primary motor cortex network. This is the first imaging evidence that the

  17. "Pulling telescoped phantoms out of the stump": manipulating the perceived position of phantom limbs using a full-body illusion.

    Science.gov (United States)

    Schmalzl, Laura; Thomke, Erik; Ragnö, Christina; Nilseryd, Maria; Stockselius, Anita; Ehrsson, H Henrik

    2011-01-01

    Most amputees experience phantom limbs, or the sensation that their amputated limb is still attached to the body. Phantom limbs can be perceived in the location previously occupied by the intact limb, or they can gradually retract inside the stump, a phenomenon referred to as "telescoping".  Telescoping is relevant from a clinical point of view, as it tends to be related to increased levels of phantom pain. In the current study we demonstrate how a full-body illusion can be used to temporarily revoke telescoping sensations in upper limb amputees. During this illusion participants view the body of a mannequin from a first person perspective while being subjected to synchronized visuo-tactile stimulation through stroking, which makes them experience the mannequin's body as their own. In Experiment 1 we used an intact mannequin, and showed that amputees can experience ownership of an intact body as well as referral of touch from both hands of the mannequin. In Experiment 2 and 3 we used an amputated mannequin, and demonstrated that depending on the spatial location of the strokes applied to the mannequin, participants experienced their phantom hand to either remain telescoped, or to actually be located below the stump. The effects were supported by subjective data from questionnaires, as well as verbal reports of the perceived location of the phantom hand in a visual judgment task. These findings are of particular interest, as they show that the temporary revoking of telescoping sensations does not necessarily have to involve the visualization of an intact hand or illusory movement of the phantom (as in the rubber hand illusion or mirror visual feedback therapy), but that it can also be obtained through mere referral of touch from the stump to the spatial location corresponding to that previously occupied by the intact hand. Moreover, our study also provides preliminary evidence for the fact that these manipulations can have an effect on phantom pain sensations.

  18. Pulling telescoped phantoms out of the stump: Manipulating the perceived position of phantom limbs using a full-body illusion

    Directory of Open Access Journals (Sweden)

    Laura eSchmalzl

    2011-11-01

    Full Text Available Most amputees experience phantom limbs, or the sensation that their amputated limb is still attached to the body. Phantom limbs can be perceived in the location previously occupied by the intact limb, or they can gradually retract inside the stump, a phenomenon referred to as telescoping. Telescoping is relevant from a clinical point of view, as it tends to be related to increased levels of phantom pain. In the current study we demonstrate how a full-body illusion can be used to temporarily revoke telescoping sensations in upper limb amputees. During this illusion participants view the body of a mannequin from a first person perspective while being subjected to synchronized visuo-tactile stimulation through stroking, which makes them experience the mannequin’s body as their own. In Experiment 1 we used an intact mannequin, and showed that amputees can experience ownership of an intact body as well as referral of touch from both hands of the mannequin. In Experiment 2 and 3 we used an amputated mannequin, and demonstrated that depending on the spatial location of the strokes applied to the mannequin, participants experienced their phantom hand to either remain telescoped, or to actually be located below the stump. The effects were supported by subjective data from questionnaires, as well as verbal reports of the perceived location of the phantom hand in a visual judgment task. These findings are of particular interest, as they show that the temporary revoking of telescoping sensations does not necessarily have to involve the visualization of an intact hand or illusory movement of the phantom (as in the rubber hand illusion or mirror visual feedback therapy, but that it can also be obtained through mere referral of touch from the stump to the spatial location corresponding to that previously occupied by the intact hand. Moreover, our study also provides preliminary evidence for the fact that these manipulations can have an effect on phantom pain

  19. Phantom limb pain: a report of two cases.

    Science.gov (United States)

    Töpfner, S; Wiech, K; Kiefer, R T; Unertl, K; Birbaumer, N

    2001-01-01

    The efficacy of pre-emptive analgesia for phantom limb pain is still unclear. It is generally accepted that pre hyphen;amputation pain increases the incidence of phantom and stump pain, even if pre-emptive analgesia is performed before and during surgery and in the postoperative period. Two cases of traumatic upper limb amputations are described here with no pre-existing pain. Both received similar antinociceptive treatment by continuous block of the brachial plexus through infusion of ropivacaine 0.375% at 5 ml/h for 10 days. Treatment of case 1 was initiated immediately after surgery; however, this amputee developed intensive phantom limb pain which persisted at 6 months. Early use of the prosthesis after surgery was not possible for this patient. The intensity of phantom limb pain in case 2 decreased significantly after 6 months, even though brachial plexus blockade was not started until 5 weeks post-trauma. This patient used a functional prosthesis intensively beginning early after amputation. Serial magnetoencephalographic recordings were performed in both patients. Only case 2 showed significant changes of cortical reorganization. In case 1 markedly less cortical plasticity was found. A combination of relevant risk factors such as a painful neuroma, behavioural and cognitive coping strategies and the early functional use of prostheses are discussed as important mechanisms contributing to the development of phantom pain and cortical reorganization. Copyright 2001 European Federation of Chapters of the International Association for the Study of Pain.

  20. Tissue-mimicking phantoms for photoacoustic and ultrasonic imaging

    Science.gov (United States)

    Cook, Jason R.; Bouchard, Richard R.; Emelianov, Stanislav Y.

    2011-01-01

    In both photoacoustic (PA) and ultrasonic (US) imaging, overall image quality is influenced by the optical and acoustical properties of the medium. Consequently, with the increased use of combined PA and US (PAUS) imaging in preclinical and clinical applications, the ability to provide phantoms that are capable of mimicking desired properties of soft tissues is critical. To this end, gelatin-based phantoms were constructed with various additives to provide realistic acoustic and optical properties. Forty-micron, spherical silica particles were used to induce acoustic scattering, Intralipid® 20% IV fat emulsion was employed to enhance optical scattering and ultrasonic attenuation, while India Ink, Direct Red 81, and Evans blue dyes were utilized to achieve optical absorption typical of soft tissues. The following parameters were then measured in each phantom formulation: speed of sound, acoustic attenuation (from 6 to 22 MHz), acoustic backscatter coefficient (from 6 to 22 MHz), optical absorption (from 400 nm to 1300 nm), and optical scattering (from 400 nm to 1300 nm). Results from these measurements were then compared to similar measurements, which are offered by the literature, for various soft tissue types. Based on these comparisons, it was shown that a reasonably accurate tissue-mimicking phantom could be constructed using a gelatin base with the aforementioned additives. Thus, it is possible to construct a phantom that mimics specific tissue acoustical and/or optical properties for the purpose of PAUS imaging studies. PMID:22076278

  1. Optimized generation of high resolution breast anthropomorphic software phantoms

    Science.gov (United States)

    Pokrajac, David D.; Maidment, Andrew D. A.; Bakic, Predrag R.

    2012-01-01

    Purpose: The authors present an efficient method for generating anthropomorphic software breast phantoms with high spatial resolution. Employing the same region growing principles as in their previous algorithm for breast anatomy simulation, the present method has been optimized for computational complexity to allow for fast generation of the large number of phantoms required in virtual clinical trials of breast imaging. Methods: The new breast anatomy simulation method performs a direct calculation of the Cooper’s ligaments (i.e., the borders between simulated adipose compartments). The calculation corresponds to quadratic decision boundaries of a maximum a posteriori classifier. The method is multiscale due to the use of octree-based recursive partitioning of the phantom volume. The method also provides user-control of the thickness of the simulated Cooper’s ligaments and skin. Results: Using the proposed method, the authors have generated phantoms with voxel size in the range of (25–1000 μm)3/voxel. The power regression of the simulation time as a function of the reciprocal voxel size yielded a log-log slope of 1.95 (compared to a slope of 4.53 of our previous region growing algorithm). Conclusions: A new algorithm for computer simulation of breast anatomy has been proposed that allows for fast generation of high resolution anthropomorphic software phantoms. PMID:22482649

  2. OSL Based Anthropomorphic Phantom and Real-Time Organ Dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    David E. Hintenlang, Ph.D

    2009-02-10

    The overall objective of this project was the development of a dosimetry system that provides the direct measurement of organ does in real-time with a sensitivity that makes it an effective tool for applications in a wide variety of health physics applications. The system included the development of a real-time readout system for fiber optic coupled (FOC) dosimeters that is integrated with a state-of-art anthropomorphic phantom to provide instantaneous measures of organ doses throughout the phantom. The small size of the FOC detectors and optical fibers allow the sensitive volume of the detector to be located at organ centroids (or multiple locations distributed through the organ) within a tissue equivalent, anthropomorphic phantom without perturbing the tissue equivalent features of the phantom. The developed phantom/dosimetry system can be used in any environment where personnel may be exposed to gamma or x-ray radiations to provide the most accurate determinations of organ and effective doses possible to date.

  3. Capturing the Perceived Phantom Limb through Virtual Reality

    Directory of Open Access Journals (Sweden)

    Christian Rogers

    2016-01-01

    Full Text Available Phantom limb is the sensation amputees may feel when the missing limb is still attached to the body and is still moving as it would if it still existed. Despite there being between 50 and 80% of amputees who report neuropathic pain, also known as phantom limb pain (PLP, there is still little understanding of why PLP occurs. There are no fully effective long-term treatments available. One of the struggles with PLP is the difficulty for amputees to describe the sensations of their phantom limbs. The sensations may be of a limb that is in a position that is impossible for a normal limb to attain. The goal of this project was to treat those with PLP by developing a system to communicate the sensations those with PLP were experiencing accurately and easily through various hand positions using a model arm with a user friendly interface. The system was developed with Maya 3D animation software, the Leap Motion input device, and the Unity game engine. The 3D modeled arm was designed to mimic the phantom sensation being able to go beyond normal joint extensions of regular arms. The purpose in doing so was to obtain a true 3D visualization of the phantom limb.

  4. High resolution, MRI-based, segmented, computerized head phantom

    Energy Technology Data Exchange (ETDEWEB)

    Zubal, I.G.; Harrell, C.R.; Smith, E.O.; Smith, A.L.; Krischlunas, P. [Yale Univ., New Haven, CT (United States). Dept. of Diagnostic Radiology

    1999-01-01

    The authors have created a high-resolution software phantom of the human brain which is applicable to voxel-based radiation transport calculations yielding nuclear medicine simulated images and/or internal dose estimates. A software head phantom was created from 124 transverse MRI images of a healthy normal individual. The transverse T2 slices, recorded in a 256x256 matrix from a GE Signa 2 scanner, have isotropic voxel dimensions of 1.5 mm and were manually segmented by the clinical staff. Each voxel of the phantom contains one of 62 index numbers designating anatomical, neurological, and taxonomical structures. The result is stored as a 256x256x128 byte array. Internal volumes compare favorably to those described in the ICRP Reference Man. The computerized array represents a high resolution model of a typical human brain and serves as a voxel-based anthropomorphic head phantom suitable for computer-based modeling and simulation calculations. It offers an improved realism over previous mathematically described software brain phantoms, and creates a reference standard for comparing results of newly emerging voxel-based computations. Such voxel-based computations lead the way to developing diagnostic and dosimetry calculations which can utilize patient-specific diagnostic images. However, such individualized approaches lack fast, automatic segmentation schemes for routine use; therefore, the high resolution, typical head geometry gives the most realistic patient model currently available.

  5. A methodology for developing anisotropic AAA phantoms via additive manufacturing.

    Science.gov (United States)

    Ruiz de Galarreta, Sergio; Antón, Raúl; Cazón, Aitor; Finol, Ender A

    2017-05-24

    An Abdominal Aortic Aneurysm (AAA) is a permanent focal dilatation of the abdominal aorta at least 1.5 times its normal diameter. The criterion of maximum diameter is still used in clinical practice, although numerical studies have demonstrated the importance of biomechanical factors for rupture risk assessment. AAA phantoms could be used for experimental validation of the numerical studies and for pre-intervention testing of endovascular grafts. We have applied multi-material 3D printing technology to manufacture idealized AAA phantoms with anisotropic mechanical behavior. Different composites were fabricated and the phantom specimens were characterized by biaxial tensile tests while using a constitutive model to fit the experimental data. One composite was chosen to manufacture the phantom based on having the same mechanical properties as those reported in the literature for human AAA tissue; the strain energy and anisotropic index were compared to make this choice. The materials for the matrix and fibers of the selected composite are, respectively, the digital materials FLX9940 and FLX9960 developed by Stratasys. The fiber proportion for the composite is equal to 0.15. The differences between the composite behavior and the AAA tissue are small, with a small difference in the strain energy (0.4%) and a maximum difference of 12.4% in the peak Green strain ratio. This work represents a step forward in the application of 3D printing technology for the manufacturing of AAA phantoms with anisotropic mechanical behavior. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Construction tool and suitability of voxel phantom for skin dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Antunes, Paula C.G.; Siqueira, Paulo T.D.; Fonseca, Gabriel P.; Yoriyaz, Helio, E-mail: ptsiquei@ipen.b, E-mail: hyoriyaz@ipen.b [Instituto de Pesquisas Energeticas e Nucleares (IPEN/CNEN-SP), Sao Paulo, SP (Brazil)

    2011-07-01

    This paper describes a new software tool called 'SkinVop' which was developed to enable accurate voxel phantom skin dosimetry. A voxel phantom is a model used to describe human anatomy in a realistic way in radiation transport codes. This model is a three-dimensional representation of the human body in the form of an array of identification numbers that are arranged in a 3D matrix. Each entry in this array represents a voxel (volume element) directly associated to the units of picture resolution (pixel) of medical images. Currently, these voxel phantoms, in association with the transport code MCNP (Monte Carlo N-Particle), have provided subsidies to the planning systems used on the hospital routine, once they afford accurate and personalized estimative of dose distribution. However, these assessments are limited to geometric representations of organs and tissues in the voxel phantom, which do not discriminates some thin body structure, such as the skin. In this context, to enable accurate dosimetric skin dose assessment by the MCNP code, it was developed this new software tool that discriminates this region with thickness and localization in the voxel phantoms similar to the real. This methodology consists in manipulating the skin volume elements by segmenting and subdividing them in different thicknesses. A graphical user interface was designed to fulfill display the modified voxel model. This methodology is extremely useful once the skin dose is inaccurately assessed of current hospital system planning, justified justly by its small thickness. (author)

  7. Radiological equipment analyzed by specific developed phantoms and software

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Campayo, J. M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Mayo, P. [TITANIA Servicios Tecnologicos SL, Sorolla Center, Local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Verdu, G.; Rodenas, F., E-mail: m.soto@lainsa.co [ISIRYIM Universidad Politecnica de Valencia, Camino de Vera s/n, Valencia (Spain)

    2010-10-15

    The use of radiographic phantoms specifically designed to evaluate the operation of the radiographic equipment lets the study of the image quality obtained by this equipment in an objective way. In digital radiographic equipment, the analysis of the image quality can be computerized because the acquisition of the image is possible in different technologies that are, computerized radiography or phosphor plate and direct radiography or detector. In case of film-screen equipment s this analysis could be applied digitalising the image in a professional scanner. In this work we have shown an application to assess automatically the constancy quality image in the image chain of the radiographic equipment s. This application is integrated by designed radiographic phantoms which are adapted to conventional, dental equipment s and specific developed software for the automatic evaluation of the phantom image quality. The software is based on digital image processing techniques that let the automatic detection of the different phantom tests by edge detector, morphological operators, threshold histogram techniques... etc. The utility developed is enough sensitive to the radiographic equipment of operating conditions of voltage (kV) and charge (m As). It is a friendly user programme connected with a data base of the hospital or clinic where it has been used. After the phantom image processing the user can obtain an inform with a resume of the imaging system state with accepting and constancy results. (Author)

  8. Induced sensorimotor brain plasticity controls pain in phantom limb patients

    Science.gov (United States)

    Yanagisawa, Takufumi; Fukuma, Ryohei; Seymour, Ben; Hosomi, Koichi; Kishima, Haruhiko; Shimizu, Takeshi; Yokoi, Hiroshi; Hirata, Masayuki; Yoshimine, Toshiki; Kamitani, Yukiyasu; Saitoh, Youichi

    2016-01-01

    The cause of pain in a phantom limb after partial or complete deafferentation is an important problem. A popular but increasingly controversial theory is that it results from maladaptive reorganization of the sensorimotor cortex, suggesting that experimental induction of further reorganization should affect the pain, especially if it results in functional restoration. Here we use a brain–machine interface (BMI) based on real-time magnetoencephalography signals to reconstruct affected hand movements with a robotic hand. BMI training induces significant plasticity in the sensorimotor cortex, manifested as improved discriminability of movement information and enhanced prosthetic control. Contrary to our expectation that functional restoration would reduce pain, the BMI training with the phantom hand intensifies the pain. In contrast, BMI training designed to dissociate the prosthetic and phantom hands actually reduces pain. These results reveal a functional relevance between sensorimotor cortical plasticity and pain, and may provide a novel treatment with BMI neurofeedback. PMID:27807349

  9. Induced sensorimotor brain plasticity controls pain in phantom limb patients.

    Science.gov (United States)

    Yanagisawa, Takufumi; Fukuma, Ryohei; Seymour, Ben; Hosomi, Koichi; Kishima, Haruhiko; Shimizu, Takeshi; Yokoi, Hiroshi; Hirata, Masayuki; Yoshimine, Toshiki; Kamitani, Yukiyasu; Saitoh, Youichi

    2016-10-27

    The cause of pain in a phantom limb after partial or complete deafferentation is an important problem. A popular but increasingly controversial theory is that it results from maladaptive reorganization of the sensorimotor cortex, suggesting that experimental induction of further reorganization should affect the pain, especially if it results in functional restoration. Here we use a brain-machine interface (BMI) based on real-time magnetoencephalography signals to reconstruct affected hand movements with a robotic hand. BMI training induces significant plasticity in the sensorimotor cortex, manifested as improved discriminability of movement information and enhanced prosthetic control. Contrary to our expectation that functional restoration would reduce pain, the BMI training with the phantom hand intensifies the pain. In contrast, BMI training designed to dissociate the prosthetic and phantom hands actually reduces pain. These results reveal a functional relevance between sensorimotor cortical plasticity and pain, and may provide a novel treatment with BMI neurofeedback.

  10. Three-dimensional printing of tissue phantoms for biophotonic imaging.

    Science.gov (United States)

    Wang, Jianting; Coburn, James; Liang, Chia-Pin; Woolsey, Nicholas; Ramella-Roman, Jessica C; Chen, Yu; Pfefer, T Joshua

    2014-05-15

    We have investigated the potential of tissue phantoms fabricated with thermosoftening- and photopolymerization-based three-dimensional (3D) printers for use in evaluation of biophotonic imaging systems. The optical properties of printed polymer samples were measured and compared to biological tissues. Phantoms with subsurface channels as small as 0.2 mm in diameter were fabricated and imaged with microscopy, x-ray microtomography, and optical coherence tomography to characterize morphology. These phantoms were then implemented to evaluate the penetration depth of a hyperspectral reflectance imaging system used in conjunction with a near-infrared contrast agent. Results indicated that 3D printing may provide a suitable platform for performance testing in biophotonics, although subsurface imaging is critical to mitigate printer-to-printer variability in matrix homogeneity and feature microstructure.

  11. Computational hybrid anthropometric paediatric phantom library for internal radiation dosimetry

    DEFF Research Database (Denmark)

    Xie, Tianwu; Kuster, Niels; Zaidi, Habib

    2017-01-01

    covering statistical distributions of body morphometry in the paediatric population. The paediatric phantoms of the Virtual Population Series (IT'IS Foundation, Switzerland) were modified to match target anthropometric parameters, including body mass, body length, standing height and sitting height...... to create 1100 female and male phantoms with 10th, 25th, 50th, 75th and 90th body morphometries. Evaluation was performed qualitatively using 3D visualization and quantitatively by analysing internal organ masses. Overall, the newly generated phantoms appear very reasonable and representative of the main...... characteristics of the paediatric population at various ages and for different genders, body sizes and sitting stature ratios. The mass of internal organs increases with height and body mass. The comparison of organ masses of the heart, kidney, liver, lung and spleen with published autopsy and ICRP reference data...

  12. Study of digital mammographic equipments by phantom image quality.

    Science.gov (United States)

    Mayo, P; Rodenas, F; Verdú, G; Campayo, J M; Villaescusa, J I

    2006-01-01

    Nowadays, the digital radiographic equipments are replacing the traditional film-screen equipments and it is necessary to update the parameters to guarantee the quality of the process. Contrast-detail phantoms are applied to digital radiography to study the threshold contrast-detail sensitivity at operation conditions of the equipment. The phantom that is studied in this work is CDMAM 3.4. One of the most extended indexes to measure the image quality in an objective way is the image quality figure (IQF). The aim of this work is to study the image quality of different images contrast-detail phantom CDMAM 3.4, carrying out the automatic detection of the contrast-detail combination and to establish a parameter which characterize in an objective way the mammographic image quality. This is useful to compare images obtained at different digital mammographic equipments to study the functioning of the equipments that facilitates the evaluation of image contrast and detail resolution.

  13. Primary motor cortex changes after amputation correlate with phantom limb pain and the ability to move the phantom limb

    DEFF Research Database (Denmark)

    Raffin, Estelle; Richard, Nathalie; Giraux, Pascal

    2016-01-01

    A substantial body of evidence documents massive reorganization of primary sensory and motor cortices following hand amputation, the extent of which is correlated with phantom limb pain. Many therapies for phantom limb pain are based upon the idea that plastic changes after amputation are maladap......A substantial body of evidence documents massive reorganization of primary sensory and motor cortices following hand amputation, the extent of which is correlated with phantom limb pain. Many therapies for phantom limb pain are based upon the idea that plastic changes after amputation...... are maladaptive and attempt to normalize representations of cortical areas adjacent to the hand area. Recent data suggest, however, that higher levels of phantom pain are associated with stronger local activity and more structural integrity in the missing hand area rather than with reorganization of neighbouring...... body parts. While these models appear to be mutually exclusive they could co-exist, and one reason for the apparent discrepancy between them might be that no single study has examined the organisation of lip, elbow, and hand movements in the same participants. In this study we thoroughly examined the 3...

  14. Design and development of an ultrasound calibration phantom and system

    Science.gov (United States)

    Cheng, Alexis; Ackerman, Martin K.; Chirikjian, Gregory S.; Boctor, Emad M.

    2014-03-01

    Image-guided surgery systems are often used to provide surgeons with informational support. Due to several unique advantages such as ease of use, real-time image acquisition, and no ionizing radiation, ultrasound is a common medical imaging modality used in image-guided surgery systems. To perform advanced forms of guidance with ultrasound, such as virtual image overlays or automated robotic actuation, an ultrasound calibration process must be performed. This process recovers the rigid body transformation between a tracked marker attached to the ultrasound transducer and the ultrasound image. A phantom or model with known geometry is also required. In this work, we design and test an ultrasound calibration phantom and software. The two main considerations in this work are utilizing our knowledge of ultrasound physics to design the phantom and delivering an easy to use calibration process to the user. We explore the use of a three-dimensional printer to create the phantom in its entirety without need for user assembly. We have also developed software to automatically segment the three-dimensional printed rods from the ultrasound image by leveraging knowledge about the shape and scale of the phantom. In this work, we present preliminary results from using this phantom to perform ultrasound calibration. To test the efficacy of our method, we match the projection of the points segmented from the image to the known model and calculate a sum squared difference between each point for several combinations of motion generation and filtering methods. The best performing combination of motion and filtering techniques had an error of 1.56 mm and a standard deviation of 1.02 mm.

  15. Realistic deformable 3D numeric phantom for transcutaneous ultrasound

    Energy Technology Data Exchange (ETDEWEB)

    Cardoso, Fernando Mitsuyama; Moraes, Matheus Cardoso; Furuie, Sergio Shiguemi, E-mail: fernando.okara@gmail.com [Universidade de Sao Paulo (USP), SP (Brazil). Escola de Engenharia

    2017-01-15

    Introduction: Numerical phantoms are important tools to design, calibrate and evaluate several methods in various image-processing applications, such as echocardiography and mammography. We present a framework for creating ultrasound numerical deformable phantoms based on Finite Element Method (FEM), Linear Isomorphism and Field II. The proposed method considers that the scatterers map is a property of the tissue; therefore, the scatterers should move according to the tissue strain. Methods: First, a volume representing the target tissue is loaded. Second, parameter values, such as Young's Modulus, scatterers density, attenuation and scattering amplitudes are inserted for each different regions of the phantom. Then, other parameters related to the ultrasound equipment, such as ultrasound frequency and number of transducer elements, are also defined in order to perform the ultrasound acquisition using Field II. Third, the size and position of the transducer and the pressures that are applied against the tissue are defined. Subsequently, FEM is executed and deformation is computed. Next, 3D linear isomorphism is performed to displace the scatterers according to the deformation. Finally, Field II is carried out to generate the non-deformed and deformed ultrasound data. Results: The framework is evaluated by comparing strain values obtained the numerical simulation and from the physical phantom from CIRS. The mean difference between both phantoms is lesser than 10%. Conclusion: The acoustic and deformation outcomes are similar to those obtained using a physical phantom. This framework led to a tool, which is available online and free of charges for educational and research purposes. (author)

  16. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  17. CT images of an anthropomorphic and anthropometric male pelvis phantom

    Energy Technology Data Exchange (ETDEWEB)

    Matos, Andrea S.D. de; Campos, Tarcisio P.R. de, E-mail: campos@nuclear.ufmg.b [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Programa de Pos-graduacao em Ciencias e Tecnicas Nucleares

    2009-07-01

    Actually, among of the most often neoplasm types are the cancer of prostate, bladder and intestine. The incidence of the intestine neoplasm in Brazil is at fourth among the most frequent tumors of the male sex, barely close to the stomach, lung and prostate incidences. Phantoms are objects used as simulators for investigating ionizing radiation transport on humans, especially during radiation therapy or radiological diagnostic. The purpose of this work is the achievement of a set of computerized tomography (CT) images of a male pelvis phantom, with anthropomorphic and anthropometric features. It investigates and analyses the set of phantom CT images in according to a correspondent human pelvis one. The reason to develop a pelvis phantom is the needs of reproducing well established spatial dose distribution in radiation therapy, especially during calibration and protocol setup for various pelvis neoplasms. It aims to produce dose optimization on radiation therapy, improving health tissue protection and keeping control tumor dose. A male pelvis phantom with similar shape made of equivalent tissues was built for simulating the ionizing radiation transport to the human body. At the phantom, pelvis organs were reproduced including the bladder, the intestine, the prostate, the muscular and greasy tissue, as well as the bone tissue and the skin. A set of CT images was carried out in axial thin sections of 2mm thickness. As results, the constituent tissues had a tomography response on Hounsfield scale similar to values found on the human pelvis. Each tissue has its respective Hounsfield value, demonstrated here. The CT images also show that the organs have equivalent anthropometric measures and anthropomorphic features of the radiological human anatomy. The anatomical physical arrangement of the organs is also similar to of the pelvis human male, having the scales of gray and numerical scale of Hounsfield compatible with the scale of the human tissue. The phantom presents

  18. Viscosity-Induced Crossing of the Phantom Barrier

    Directory of Open Access Journals (Sweden)

    Iver Brevik

    2015-09-01

    Full Text Available We show explicitly, by using astrophysical data plus reasonable assumptions for the bulk viscosity in the cosmic fluid, how the magnitude of this viscosity may be high enough to drive the fluid from its position in the quintessence region at present time t = 0 across the barrier w = −1 into the phantom region in the late universe. The phantom barrier is accordingly not a sharp mathematical divide, but rather a fuzzy concept. We also calculate the limiting forms of various thermodynamical quantities, including the rate of entropy production, for a dark energy fluid near the future Big Rip singularity.

  19. Development of PIMAL: Mathematical Phantom with Moving Arms and Legs

    Energy Technology Data Exchange (ETDEWEB)

    Akkurt, Hatice [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Eckerman, Keith F. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2007-05-01

    The computational model of the human anatomy (phantom) has gone through many revisions since its initial development in the 1970s. The computational phantom model currently used by the Nuclear Regulatory Commission (NRC) is based on a model published in 1974. Hence, the phantom model used by the NRC staff was missing some organs (e.g., neck, esophagus) and tissues. Further, locations of some organs were inappropriate (e.g., thyroid).Moreover, all the computational phantoms were assumed to be in the vertical-upright position. However, many occupational radiation exposures occur with the worker in other positions. In the first phase of this work, updates on the computational phantom models were reviewed and a revised phantom model, which includes the updates for the relevant organs and compositions, was identified. This revised model was adopted as the starting point for this development work, and hence a series of radiation transport computations, using the Monte Carlo code MCNP5, was performed. The computational results were compared against values reported by the International Commission on Radiation Protection (ICRP) in Publication 74. For some of the organs (e.g., thyroid), there were discrepancies between the computed values and the results reported in ICRP-74. The reasons behind these discrepancies have been investigated and are discussed in this report.Additionally, sensitivity computations were performed to determine the sensitivity of the organ doses for certain parameters, including composition and cross sections used in the simulations. To assess the dose for more realistic exposure configurations, the phantom model was revised to enable flexible positioning of the arms and legs. Furthermore, to reduce the user time for analyses, a graphical user interface (GUI) was developed. The GUI can be used to visualize the positioning of the arms and legs as desired posture is achieved to generate the input file, invoke the computations, and extract the organ dose

  20. Genetics of Tinnitus: Time to Biobank Phantom Sounds

    Directory of Open Access Journals (Sweden)

    Christopher R. Cederroth

    2017-09-01

    Full Text Available Tinnitus is a common phantom sensation resulting most often from sensory deprivation, and for which little knowledge on the molecular mechanisms exists. While the existing evidence for a genetic influence on the condition has been until now sparse and underpowered, recent data suggest that specific forms of tinnitus have a strong genetic component revealing that not all tinnitus percepts are alike, at least in how they are genetically driven. These new findings pave the way for a better understanding on how phantom sensations are molecularly driven and call for international biobanking efforts.

  1. Design of a Compact and Versatile Bench Scale Tubular Reactor

    Directory of Open Access Journals (Sweden)

    R. Prasad

    2009-06-01

    Full Text Available A compact and versatile laboratory tubular reactor has been designed and fabricated keeping in view of reducing capital cost and minimising energy consumption for gas/vapor-phase heterogeneous catalytic reactions. The reactor is consisted of two coaxial corning glass tubes with a helical coil of glass tube in between the coaxial tubes serving as vaporiser and pre-heater, the catalyst bed is in the inner tube. A schematic diagram of the reactor with detailed dimensions and working principles are described. The attractive feature of the reactor is that the vaporiser, pre-heater and fixed bed reactor are merged in a single compact unit. Thus, the unit minimises separate vaporiser and pre-heater, also avoids separate furnaces used for them and eliminate auxiliary instrumentation such as temperature controller etc. To demonstrate the system operation and illustrate the key features, catalyst screening data and the efficient collection of complete, and accurate intrinsic kinetic data are provided for oxidation of CO over copper chromite catalyst. CO oxidation is an important reaction for auto-exhaust pollution control. The suitability of the versatile nature of the reactor has been ascertained for catalytic reactions where either volatile or vaporizable feeds can be introduced to the reaction zone, e.g. oxidation of iso-octane, reduction of nitric oxide, dehydrogenation of methanol, ethanol and iso-propanol, hydrogenation of nitrobenzene to aniline, etc. Copyright (c 2009 by BCREC. All Rights reserved.[Received: 10 February 2009, Accepted: 9 May 2009][How to Cite: R. Prasad, G. Rattan. (2009. Design of a Compact and Versatile Bench Scale Tubular Reactor. Bulletin of Chemical Reaction Engineering and Catalysis, 4(1: 5-9.  doi:10.9767/bcrec.4.1.1250.5-9][How to Link/ DOI: http://dx.doi.org/10.9767/bcrec.4.1.1250.5-9

  2. Versatile transmission ellipsometry to study linear ferrofluid magneto-optics.

    Science.gov (United States)

    Kooij, E S; Gâlcă, A C; Poelsema, B

    2006-12-01

    Linear birefringence and dichroism of magnetite ferrofluids are studied simultaneously using spectroscopic ellipsometry in transmission mode. It is shown that this versatile technique enables highly accurate characterisation of magneto-optical phenomena. Magnetic field-dependent linear birefringence and dichroism as well as the spectral dependence are shown to be in line with previous results. Despite the qualitative agreement with established models for magneto-optical phenomena, these fail to provide an accurate, quantitative description of our experimental results using the bulk dielectric function of magnetite. We discuss the results in relation to these models, and indicate how the modified dielectric function of the magnetite nanoparticles can be obtained.

  3. Versatile supramolecular organogel with outstanding stability toward aqueous interfaces.

    Science.gov (United States)

    Bonifazi, Evelyn L; Edelsztein, Valeria C; Menéndez, Guillermo O; Samaniego López, Cecilia; Spagnuolo, Carla C; Di Chenna, Pablo H

    2014-06-25

    In this communication, we report on a novel and versatile low-molecular-weight organogelator. The methanolic gel exhibits an exceptional water-enhanced stability as evidenced by a 30 °C increase in Tg with up to 10%v/v of water. This atypical property not observed with other solvents makes of this supramolecular gel a highly stable matrix compatible with aqueous interfaces. As a proof of principle we present the sensing performance of a symmetric tricarbocyanine fluorophore bearing a Zn(II)chelator unit. The system retained its remarkable physical integrity for a long period of time opening new possibilities for other organic-aqueous interface applications.

  4. A Versatile Glass Processor for High-Performance Photonic Platforms

    Science.gov (United States)

    2015-12-08

    SECURITY CLASSIFICATION OF: With the DURIP fund, we acquire a glass processing station to enhance our capabilities to achieve ultra-high performance...funded by PECASE (supported by DoD-ARO under the contract/grant number W911NF-12-1-0026) on high performance optical sensors. The multipurpose glass ...Distribution Unlimited UU UU UU UU 08-12-2016 1-Aug-2014 31-Jul-2015 Final Report: A Versatile Glass Processor for High-Performance Photonic Platforms The views

  5. CORRTEX: a compact and versatile system for time domain reflectometry

    Energy Technology Data Exchange (ETDEWEB)

    Deupree, R.G.; Eilers, D.D.; McKown, T.O.; Storey, W.H.

    1981-01-01

    The CORRTEX (COntinuous Reflectometry for Radius versus Time EXperiments) system was designed to be an adaptable and versatile unit for performing time domain reflectometry (TDR). The system consists of a coaxial cable, a digital TDR, which uses a Motorola 6800 microprocessor, a power source or battery pack, and an output terminal or recording driver. Desirable criteria for the system are discussed as well as the operation of the CORRTEX system. The types of present applications of the CORRTEX system are summarized and data presented.

  6. Read-only holographic versatile disc system using laser diode

    Science.gov (United States)

    Horimai, Hideyoshi; Tan, Xiaodi

    2006-05-01

    A Read-only Holographic Versatile Disc (HVD-ROM) system, using a laser diode for high capacity and high data transfer rates storage system, is proposed. With the collinear technologies' unique configuration the optical pickup can be designed as small as a DVD's, and can be placed on one side of the disc. With the HVD's special structure, the system can servo the focus/tracking and locate reading/writing address. The experiments and theoretical studies suggest that a laser diode is very suitable as a light source of our HVD-ROM system.

  7. The Q-System: A Versatile Expression System for Drosophila.

    Science.gov (United States)

    Riabinina, Olena; Potter, Christopher J

    2016-01-01

    Binary expression systems are flexible and versatile genetic tools in Drosophila. The Q-system is a recently developed repressible binary expression system that offers new possibilities for transgene expression and genetic manipulations. In this review chapter, we focus on current state-of-the-art Q-system tools and reagents. We also discuss in vivo applications of the Q-system, together with GAL4/UAS and LexA/LexAop systems, for simultaneous expression of multiple effectors, intersectional labeling, and clonal analysis.

  8. Versatile test rig for the evaluation of thermionic electron guns

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, H.; Cleaver, J.R.A. (Cambridge Univ. (UK). Dept. of Engineering); Catto, C.J.D. (Cambridge Sanning Ltd. (UK)); Kanitkar, P.L. (Poona Univ. (India). Dept. of Physics); Smith, D.J. (Cambridge Univ. (UK). High Resolution Electron Microscope)

    1982-12-01

    Measurements of the brightness and the electron energy distribution for high-performance electron guns for electron-optical instruments must take account of the small effective size of the electron source and the directional dependence of the emission from it. A versatile electron gun test rig has been developed to enable measurements to be made under realistic operating conditions. Energy distribution can be determined with a hemispherical cup retarding-field analyser, and brightness can be measured at up to 100 kV by both two-aperture and crossover-projection methods. Some measured characteristics of lanthanum hexaboride cathodes are given, with measurements of conventional tungsten cathodes for comparison.

  9. Monte Carlo Evaluation of Gamma Knife Dose Profile in Real Brain Phantom

    Directory of Open Access Journals (Sweden)

    Ali Aghaebrahimian

    2016-03-01

    The calculation of the real phantom showed that water and polystyrene could function similarly, while evaluating dosimetry parameters in the Gamma Knife system; thus, water and polystyrene are not appropriate phantom matters for this purpose.

  10. Design and development of a telerehabilitation platform for patients with phantom limb pain

    NARCIS (Netherlands)

    Andreas Rothgangel; Susy Braun; Rob Smeets; Anna Beurskens

    2017-01-01

    Background: Phantom limb pain is a frequent and persistent problem following amputation. Achieving sustainable favorable effects on phantom limb pain requires therapeutic interventions such as mirror therapy that target maladaptive neuroplastic changes in the central nervous system. Unfortunately,

  11. Human torso phantom for imaging of heart with realistic modes of cardiac and respiratory motion

    Science.gov (United States)

    Boutchko, Rostyslav; Balakrishnan, Karthikayan; Gullberg, Grant T; O& #x27; Neil, James P

    2013-09-17

    A human torso phantom and its construction, wherein the phantom mimics respiratory and cardiac cycles in a human allowing acquisition of medical imaging data under conditions simulating patient cardiac and respiratory motion.

  12. Computerized quantitative evaluation of mammographic accreditation phantom images

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yongbum; Tsai, Du-Yih; Shinohara, Norimitsu [Department of Radiological Technology, School of Health Sciences, Niigata University, 2-746 Asahimachidori, Chuouku, Niigata 951-8518 (Japan); Department of Radiological Technology, Gifu Univesity of Medical Science, 1-795 Hiraga-aza-nagamine, Seki, Gifu 501-3892 (Japan)

    2010-12-15

    Purpose: The objective was to develop and investigate an automated scoring scheme of the American College of Radiology (ACR) mammographic accreditation phantom (RMI 156, Middleton, WI) images. Methods: The developed method consisted of background subtraction, determination of region of interest, classification of fiber and mass objects by Mahalanobis distance, detection of specks by template matching, and rule-based scoring. Fifty-one phantom images were collected from 51 facilities for this study (one facility provided one image). A medical physicist and two radiologic technologists also scored the images. The human and computerized scores were compared. Results: In terms of meeting the ACR's criteria, the accuracies of the developed method for computerized evaluation of fiber, mass, and speck were 90%, 80%, and 98%, respectively. Contingency table analysis revealed significant association between observer and computer scores for microcalcifications (p<5%) but not for masses and fibers. Conclusions: The developed method may achieve a stable assessment of visibility for test objects in mammographic accreditation phantom image in whether the phantom image meets the ACR's criteria in the evaluation test, although there is room left for improvement in the approach for fiber and mass objects.

  13. The perception of phantom limbs. The D. O. Hebb lecture.

    Science.gov (United States)

    Ramachandran, V S; Hirstein, W

    1998-09-01

    Almost everyone who has a limb amputated will experience a phantom limb--the vivid impression that the limb is not only still present, but in some cases, painful. There is now a wealth of empirical evidence demonstrating changes in cortical topography in primates following deafferentation or amputation, and this review will attempt to relate these in a systematic way to the clinical phenomenology of phantom limbs. With the advent of non-invasive imaging techniques such as MEG (magnetoencephalogram) and functional MRI, topographical reorganization can also be demonstrated in humans, so that it is now possible to track perceptual changes and changes in cortical topography in individual patients. We suggest, therefore, that these patients provide a valuable opportunity not only for exploring neural plasticity in the adult human brain but also for understanding the relationship between the activity of sensory neurons and conscious experience. We conclude with a theory of phantom limbs, some striking demonstrations of phantoms induced in normal subjects, and some remarks about the relevance of these phenomena to the question of how the brain constructs a 'body image.'

  14. [Evaluation of ultrasound hyperthermia system with a phantom model].

    Science.gov (United States)

    Ono, S; Hirose, T; Shiba, T; Kuriya, K; Watanabe, K

    1996-03-01

    Ultrasound (US) hyperthermia is a local heating method that has recently been introduced into clinical practice. A prototype and modified version of this system using a phantom model (agar with bone inserted) were evaluated. The prototype system consists of a power delivery unit (0.5 MHz frequency) with a circulating cooled water bolus. This system heats a shallow area irrespective of power output, but has a tendency to overheat the phantom surface. We incorporated three modifications into the prototype. The modified type has three frequency applicators (0.5, 1.0, 1.5MHz) and a secondary bolus. Aluminum-urethane shields were used to cover the phantom surface located over bone preventing overheating of bone. By changing the applicator's US frequency, we could change the depth of the heating area. Overheating of the phantom surface and bone thus was avoided. These results suggest that our modified US hyperthermia system with multiple frequency applicators, a secondary bolus and aluminum-urethane shields provided a good heating pattern.

  15. Anisotropic Bianchi-I universe with phantom field and cosmological ...

    Indian Academy of Sciences (India)

    of the cosmological solutions. Keywords. Anisotropic cosmology; phantom field; accelerating universe. PACS Nos 04.20.Jb; 98.80.Cq. 1. Introduction. Recent astrophysical data obtained from high redshift surveys of Supernovae,. COBE to WMAP predict that the present universe is passing through an accel- erating phase of ...

  16. Measuring Phantom Recollection in the Simplified Conjoint Recognition Paradigm

    Science.gov (United States)

    Stahl, Christoph; Klauer, Karl Christoph

    2009-01-01

    False memories are sometimes strong enough to elicit recollective experiences. This phenomenon has been termed Phantom Recollection (PR). The Conjoint Recognition (CR) paradigm has been used to empirically separate PR from other memory processes. Recently, a simplification of the CR procedure has been proposed. We herein extend the simplified CR…

  17. Comparative attenuation spectra of liquid skin-like phantoms

    CSIR Research Space (South Africa)

    Singh, A

    2010-09-01

    Full Text Available This study aims to extract and compare attenuation coefficients of different liquid skin-like phantoms representing Skin Types 1 to V1 with two methods, Spectrophotometric and Integrating Sphere methods. The correlation between the results of the 2...

  18. Cosmological model of interacting phantom and Yang–Mills fields

    Indian Academy of Sciences (India)

    2015-11-27

    Nov 27, 2015 ... In this paper, we consider a model of interacting phantom and Yang–Mills (YM) fields by assuming dilaton-type coupling. Using the specific solution for YM equation previously found by the author, we obtain simple exact solutions for the accelerated expansion of the Friedmann–Robertson–Walker (FRW) ...

  19. Home based Tactile Discrimination Training (TDT) reduces phantom limb pain.

    Science.gov (United States)

    Wakolbinger, Robert; Diers, Martin; Hruby, Laura A; Sturma, Agnes; Aszmann, Oskar C

    2017-11-06

    Phantom limb pain (PLP) affects a high percentage of amputees. Since treatment options are limited, low quality of life and addiction to pain medication is frequent. New attempts, such as mirror therapy or electrical sensory discrimination training, make use of the brain's plasticity to alleviate this centrally derived pain. This pilot study assessed the question, whether home-based tactile discrimination training (TDT) leads to a stronger decrease in phantom limb pain levels, compared to a standard massage treatment. Controlled study. Outpatient. Amputees (upper/lower extremity) with PLP of VAS 4/10 or higher. Eight patients participated in the study. The treatment phase comprised two weeks (15min daily). Subjects were examined at baseline, after treatment, two weeks after and four weeks after completing the treatment. Pain was assessed with the West Haven Multidimensional Pain Inventory. There was a significantly stronger reduction in phantom limb pain in the treatment group receiving TDT. Phantom limb pain intensity ratings were significantly reduced at the end of therapy, two weeks after as well as four weeks after compared to pre-treatment. TDT seems to be an easy, cheap, time-effective and safe method to achieve sustained alleviation in PLP and also brings about a positive change in body image. Home-based TDT could achieve sustained reduction in PLP and should be considered as possible alternative to established treatment methods. This article is protected by copyright. All rights reserved. This article is protected by copyright. All rights reserved.

  20. Phantom model of physiologic intracranial pressure and cerebrospinal fluid dynamics.

    Science.gov (United States)

    Bottan, Simone; Poulikakos, Dimos; Kurtcuoglu, Vartan

    2012-06-01

    We describe herein a novel life-size phantom model of the intracranial cavity and its validation. The cerebrospinal fluid (CSF) domains including ventricular, cysternal, and subarachnoid spaces were derived via magnetic resonance imaging. Brain mechanical properties and cranio-spinal compliance were set based on published data. Both bulk and pulsatile physiologic CSF flow were modeled. Model validation was carried out by comparisons of flow and pressure measurements in the phantom with published in vivo data of healthy subjects. Physiologic intracranial pressure with 10 mmHg mean and 0.4 mmHg peak pulse amplitude was recorded in the ventricles. Peak CSF flow rates of 0.2 and 2 ml/s were measured in the cerebral aqueduct and subarachnoid space, respectively. The phantom constitutes a first-of-its-kind approach to modeling physiologic intracranial dynamics in vitro. Herein, we describe the phantom design and manufacturing, definition and implementation of its operating parameters, as well as the validation of the modeled dynamics.

  1. Uniqueness of higher-dimensional phantom field wormholes

    Science.gov (United States)

    Rogatko, Marek

    2018-01-01

    Based on the rigid positive energy theorem we proved the uniqueness of static spherically symmetric traversable wormholes with two asymptotically flat ends, being the higher-dimensional solutions of Einstein scalar phantom field. The proof is valid under the auxiliary condition imposed on wormhole mass and scalar charge.

  2. Temperature distributions obtained with diathermy electrodes implanted into a phantom.

    Science.gov (United States)

    Wasserman, H J; Levin, W

    1979-11-01

    Uniform patterns of heating in a homogeneous phantom were obtained by implanting shortwave diathermy electrodes in a particular configuration. The methods of heating and measurement are described. The technique can be considered for applying localized hyperthermia in the treatment of cancer.

  3. THE EFFECT OF PHANTOM GROUPS ON GENETIC TREND

    African Journals Online (AJOL)

    Helena Theron

    the South African Holstein population. EBV – estimated breeding value. The DYD test of Boichard et al. (1995) indicated a significant underestimation in the genetic trend when phantom parent groups were not included in the model. The values of 01*σg for milk, butterfat and protein were 5.97, 0.20 and 0.17 respectively.

  4. AdS Black Hole with Phantom Scalar Field

    Directory of Open Access Journals (Sweden)

    Limei Zhang

    2017-01-01

    Full Text Available We present an AdS black hole solution with Ricci flat horizon in Einstein-phantom scalar theory. The phantom scalar fields just depend on the transverse coordinates x and y, which are parameterized by the parameter α. We study the thermodynamics of the AdS phantom black hole. Although its horizon is a Ricci flat Euclidean space, we find that the thermodynamical properties of the black hole solution are qualitatively the same as those of AdS Schwarzschild black hole. Namely, there exists a minimal temperature and the large black hole is thermodynamically stable, while the smaller one is unstable, so there is a so-called Hawking-Page phase transition between the large black hole and the thermal gas solution in the AdS space-time in Poincare coordinates. We also calculate the entanglement entropy for a strip geometry dual to the AdS phantom black holes and find that the behavior of the entanglement entropy is qualitatively the same as that of the black hole thermodynamical entropy.

  5. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited

    NARCIS (Netherlands)

    Xia, W.; Piras, D.; Heijblom, M.; Steenbergen, Wiendelt; van Leeuwen, Ton; Manohar, Srirang

    2011-01-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F–T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where

  6. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited.

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  7. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited

    Science.gov (United States)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G.; Manohar, Srirang

    2011-07-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where temperature distributions during F-T are relatively homogeneous. In this work, in breast-sized samples we observed substantial temperature differences between the shallow regions and the interior during the F-T procedure. We investigated whether spatial variations were also present in the acoustic and optical properties. The speed of sound, acoustic attenuation, and optical reduced scattering coefficients were measured on specimens sampled at various locations in a large phantom. In general, the properties matched values quoted for breast tissue. But while acoustic properties were relatively homogeneous, the reduced scattering was substantially different at the surface compared with the interior. We correlated these variations with gel microstructure inspected using scanning electron microscopy. Interestingly, the phantom's reduced scattering spatial distribution matches the optical properties of the standard two-layer breast model used in x ray dosimetry. We conclude that large PVA samples prepared using the standard recipe make excellent breast tissue phantoms.

  8. Poly(vinyl alcohol) gels as photoacoustic breast phantoms revisited

    NARCIS (Netherlands)

    Xia, Wenfeng; Piras, Daniele; Heijblom, Michelle; Steenbergen, Wiendelt; van Leeuwen, Ton G.; Manohar, Srirang

    2011-01-01

    A popular phantom in photoacoustic imaging is poly(vinyl alcohol) (PVA) hydrogel fabricated by freezing and thawing (F-T) aqueous solutions of PVA. The material possesses acoustic and optical properties similar to those of tissue. Earlier work characterized PVA gels in small test specimens where

  9. Accurately characterized optical tissue phantoms: how, why and when?

    Science.gov (United States)

    Bouchard, Jean-Pierre; Veilleux, Isra"l.; Noiseux, Isabelle; Mermut, Ozzy

    2011-03-01

    Optical tissue phantoms are very important tools for the development of biomedical imaging applications. Optical phantoms are often used as ground truth against which instruments results can be compared. It is therefore important that the optical properties of reference phantoms be measured in a manner that is traceable to the international system of units. SI traceability insures long term consistency of results and will therefore improve the effectiveness of diffuse optics research effort more effective by reducing unwanted variability in the data produced and shared by the community. The ultimate benefit of rigorous SI traceability is the reduction of variability in the data produced by novel diagnostic devices, which will in turn increase the statistical power of clinical trials aiming at validating their clinical usefulness. SI traceability, and therefore uncertainty analysis, is also relevant to traceability aspects mandated by FDA regulations. SI traceability is achieved through a thorough analysis of the measurement principle and its potential error sources. The uncertainty analysis should be ultimately validated by inter-laboratory comparison until a consensus is attained on the best practices for measuring the optical properties of tissue phantoms.

  10. A computational phantom of head and neck - SISCODES

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Larissa; Trindade, Bruno Machado; Campos, Tarcisio Passos Ribeiro [Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil). Dept. de Engenharia Nuclear. Programa de Pos-Graduacao em Ciencias e Tecnicas Nucleares]. E-mail: larissa.thompson@ig.com.br; bmtrindade@yahoo.com; campos@nuclear.ufmg.br

    2007-07-01

    A computational voxel model of a head and neck adult male was built through the SISCODES code, in order to complement and to optimize the radiotherapic treatment in head and neck cancer, in terms of dosimetric evaluation and prediction. This computational simulator object, namely computational phantom, is a useful tool for the elaboration and simulation of the three-dimensional radiation planning. The present phantom was assembled based on information generated by photographic images of the visible human project. The images were digitalized and converted one by one to a matrix of voxel, in which tissues and its respective chemical composition were identified, with the helping of a biomedical and nuclear data bank including in SISCODES. A computational simulation of an external beam mimicking a Co-60 irradiator was prepared, reproducing a radiation window equivalent to one found in a lateral irradiation of a nasopharyngeal tumour in situ. Absorbed dose evaluation in the internal regions of the phantom are presented and demonstrated through spatial dose distribution, superimposed with the 2D phantom sections. The present article illustrates the possibility of generating information of the spatial dose distribution including all adjacent tissues, far from tumour, improving the radiodosimetry and creating the possibility of investigating neurological deficits, dysphagia, and speaking and hearing alterations, non evaluated in the present stage of radiation therapy of head and neck. (author)

  11. Phantom dosimetry at 15 MV conformal radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Larissa; Campos, Tarcisio P.R., E-mail: larissathompson@hotmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Dias, Humberto G., E-mail: fisicamedica.hl@mariopenna.org.br [Luxemburgo Hospital, Mario Penna Institute, Belo Horizonte, MG (Brazil)

    2015-07-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  12. Phantom dosimetry at 15 MV conformal radiation therapy

    Energy Technology Data Exchange (ETDEWEB)

    Thompson, Larissa; Campos, Tarcisio P.R., E-mail: larissathompson@hotmail.com, E-mail: tprcampos@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Minas Gerais, MG (Brazil). Dept. de Engenharia Nuclear; Dias, Humberto G., E-mail: fisicamedica.hl@mariopenna.org.br [Instituto Mario Penna, Minas Gerais, MG (Brazil). Hospital Luxemburgo

    2013-07-01

    The main goal of this work was to evaluate the spatial dose distribution into a tumor simulator inside a head phantom exposed to a 15MV 3D conformal radiation therapy in order to validate internal doses. A head and neck phantom developed by the Ionizing Radiation Research Group (NRI) was used on the experiments. Therapy Radiation planning (TPS) was performed based on those CT images, satisfying a 200 cGy prescribed dose split in three irradiation fields. The TPS assumed 97% of prescribed dose cover the prescribed treatment volume (PTV). Radiochromic films in a solid water phantom provided dose response as a function of optical density. Spatial dosimetric distribution was generated by radiochromic film samples inserted into tumor simulator and brain. The spatial dose profiles held 70 to 120% of the prescribed dose. In spite of the stratified profile, as opposed to the smooth dose profile from TPS, the tumor internal doses were within a 5% deviation from 214.4 cGy evaluated by TPS. 83.2% of the points with a gamma value of less than 1 (3%/3mm) for TPS and experimental values, respectively. At the tumor, a few dark spots in the film caused the appearance of outlier points in 13-15% of dose deviation percentage. As final conclusion, such dosimeter choice and the physical anthropomorphic and anthropometric phantom provided an efficient method for validating radiotherapy protocols. (author)

  13. Gravitational Quasinormal Modes of Regular Phantom Black Hole

    Directory of Open Access Journals (Sweden)

    Jin Li

    2017-01-01

    Full Text Available We investigate the gravitational quasinormal modes (QNMs for a type of regular black hole (BH known as phantom BH, which is a static self-gravitating solution of a minimally coupled phantom scalar field with a potential. The studies are carried out for three different spacetimes: asymptotically flat, de Sitter (dS, and anti-de Sitter (AdS. In order to consider the standard odd parity and even parity of gravitational perturbations, the corresponding master equations are derived. The QNMs are discussed by evaluating the temporal evolution of the perturbation field which, in turn, provides direct information on the stability of BH spacetime. It is found that in asymptotically flat, dS, and AdS spacetimes the gravitational perturbations have similar characteristics for both odd and even parities. The decay rate of perturbation is strongly dependent on the scale parameter b, which measures the coupling strength between phantom scalar field and the gravity. Furthermore, through the analysis of Hawking radiation, it is shown that the thermodynamics of such regular phantom BH is also influenced by b. The obtained results might shed some light on the quantum interpretation of QNM perturbation.

  14. Versatile aggressive mimicry of cicadas by an Australian predatory katydid.

    Directory of Open Access Journals (Sweden)

    David C Marshall

    Full Text Available BACKGROUND: In aggressive mimicry, a predator or parasite imitates a signal of another species in order to exploit the recipient of the signal. Some of the most remarkable examples of aggressive mimicry involve exploitation of a complex signal-response system by an unrelated predator species. METHODOLOGY/PRINCIPAL FINDINGS: We have found that predatory Chlorobalius leucoviridis katydids (Orthoptera: Tettigoniidae can attract male cicadas (Hemiptera: Cicadidae by imitating the species-specific wing-flick replies of sexually receptive female cicadas. This aggressive mimicry is accomplished both acoustically, with tegminal clicks, and visually, with synchronized body jerks. Remarkably, the katydids respond effectively to a variety of complex, species-specific Cicadettini songs, including songs of many cicada species that the predator has never encountered. CONCLUSIONS/SIGNIFICANCE: We propose that the versatility of aggressive mimicry in C. leucoviridis is accomplished by exploiting general design elements common to the songs of many acoustically signaling insects that use duets in pair-formation. Consideration of the mechanism of versatile mimicry in C. leucoviridis may illuminate processes driving the evolution of insect acoustic signals, which play a central role in reproductive isolation of populations and the formation of species.

  15. Iron: a versatile element to produce materials for environmental applications

    Energy Technology Data Exchange (ETDEWEB)

    Teixeira, Ana Paula C.; Araujo, Maria H.; Oliveira, Luiz C.A.; Moura, Flavia C.C.; Lago, Rochel M., E-mail: rochel@ufmg.br, E-mail: anapct@ufmg.br [Departamento de Quimica, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil); Tristao, Juliana C. [Universidade Federal de Vicosa, Florestal, MG (Brazil); Ardisson, Jose D. [Centro de Desenvolvimento da Tecnologia Nuclear (CDTN/CNEN-MG), Belo Horizonte, MG (Brazil). Lab. de Fisica Aplicada; Amorim, Camila C., E-mail: juliana@ufv.br [Departamento de Engenharia Sanitaria e Ambiental, Universidade Federal de Minas Gerais, Belo Horizonte, MG (Brazil)

    2012-09-15

    Iron is a versatile element forming several phases with different oxidation states and {sup s}tructures, such as Fe{sup 0}, FeO, Fe{sub 3}O{sub 4}, {gamma}-Fe{sub 2}O{sub 3}, {alpha}-Fe{sub 2}O{sub 3} and FeOOH. All these phases have unique physicochemical properties which can be used for different applications. In this work, it is described the use of different iron compounds, synthetic and also from natural and waste sources, in environmental and technological applications. Two main research areas are described. The first one is related to strategies to increase the reactivity of Fe phases, mainly by the formation of Fe{sup 0}/iron oxide composites and by the introduction of new metals in the iron oxide structure to promote new surface reactions. The second area is the use of the magnetic properties of some iron phases to produce versatile magnetic materials with focus in adsorption, catalysis and emulsions. (author)

  16. Versatile equipment for mechanical testing of active materials

    Energy Technology Data Exchange (ETDEWEB)

    Bertsch, Johannes; Heimgartner, Peter

    2005-01-01

    At the Paul Scherrer Institute (PSI) 3 different project groups presently perform aging research on active materials. The research fields are fusion, high neutron flux targets and LWR relevant components. Up to now mechanical testing has been performed with small, low dose rate samples behind local shielding, not appropriate for highly activated material. To overcome this situation, a cell concept for active mechanical testing was elaborated and has been erected in PSI's Hotlab. It consists of 4 shielded cells. 3 connected cells are versatile and independently operable for highly beta/gamma active samples. One cell is an alpha/beta/gamma-box which will be realized in a second phase. This paper presents the versatility especially of the beta/gamma-cells: The different user groups perform experiments in these cells, whereas different machines can be placed into the cells. As consequence of the need of heavily shielded cell doors, a special strengthening and levelling of the floor has been required. In all cells the relevant media are installed. Besides the performance of the cells, the project progress as the difficulties and their solutions are described. (Author)

  17. Versatile ferrofluids based on polyethylene glycol coated iron oxide nanoparticles

    Energy Technology Data Exchange (ETDEWEB)

    Brullot, W., E-mail: ward.brullot@fys.kuleuven.be [Department of Chemistry, Katholieke Universiteit Leuven, Celestijnenlaan 200D, 3001 Heverlee, Leuven (Belgium); Reddy, N.K. [Department of Chemical Engineering, Katholieke Universiteit Leuven, Willem de Croylaan 46, 3001 Heverlee, Leuven (Belgium); Wouters, J.; Valev, V.K.; Goderis, B. [Department of Chemistry, Katholieke Universiteit Leuven, Celestijnenlaan 200D, 3001 Heverlee, Leuven (Belgium); Vermant, J. [Department of Chemical Engineering, Katholieke Universiteit Leuven, Willem de Croylaan 46, 3001 Heverlee, Leuven (Belgium); Verbiest, T. [Department of Chemistry, Katholieke Universiteit Leuven, Celestijnenlaan 200D, 3001 Heverlee, Leuven (Belgium)

    2012-06-15

    Versatile ferrofluids based on polyethylene glycol coated iron oxide nanoparticles were obtained by a facile protocol and thoroughly characterized. Superparamagnetic iron oxide nanoparticles synthesized using a modified forced hydrolysis method were functionalized with polyethylene glycol silane (PEG silane), precipitated and dried. These functionalized particles are dispersable in a range of solvents and concentrations depending on the desired properties. Examples of tunable properties are magnetic behavior, optical and magneto-optical response, thermal features and rheological behavior. As such, PEG silane functionalized particles represent a platform for the development of new materials that have broad applicability in e.g. biomedical, industrial or photonic environments. Magnetic, optical, magneto-optical, thermal and rheological properties of several ferrofluids based on PEG coated particles with different concentrations of particles dispersed in low molecular mass polyethylene glycol were investigated, establishing the applicability of such materials. - Highlights: Black-Right-Pointing-Pointer Ferrofluids based on polyethylene glycol coated iron oxide nanoparticles. Black-Right-Pointing-Pointer Magnetic, optical, magneto-optical, thermal and rheological characterization of ferrofluids. Black-Right-Pointing-Pointer Tunable properties of versatile polyethylene glycol stabilized ferrofluids.

  18. A versatile patterning process based on easily soluble sacrificial bilayers

    Science.gov (United States)

    Harada, Takayuki; Tsukazaki, Atsushi

    2017-08-01

    Development of a microfabrication process is essential to embed fascinating physical properties of functional materials into mesoscopic devices. Different from well-investigated materials with established microfabrication process, newly-discovered materials often meet difficulty when scaling down into a mesoscopic size, because process damages cause serious deterioration of their functionalities. Here, we demonstrate a versatile lift-off method using a carefully designed sacrificial bilayer, composed of an easily soluble layer and a thermally stable rigid layer. In this method, the target films can be grown in optimum conditions, such as high temperature and high oxygen partial pressure, on the stable pre-patterned substrate with the inorganic sacrificial bilayer. After film deposition, measurable patterned devices can be obtained just by a short-time lift-off in a mild chemical solution. We carried out micron-scale patterning and electrical measurements by applying this technique to one of perovskite oxides, SrRuO3, and Fe-based chalcogenide superconductors, FeSe, both of which are incompatible with conventional photolithography and dry-etching processes. The demonstrated narrowest line width of 5 μm is successfully patterned with maintaining the almost identical properties of the pristine films, exemplifying that process damage is minimized. The demonstrated versatile patterning process expands the range of application of emerging functional materials in thin film devices.

  19. Tissue-Like Phantoms as a Platform for Inserted Fluorescence Nano-Probes

    OpenAIRE

    Nayhoz, Tsviya; Barnoy, Eran A.; Fixler, Dror

    2016-01-01

    Tissue-like phantoms are widely used as a model for mimicking the optical properties of live tissue. This paper presents the results of a diffusion reflection method and fluorescence lifetime imaging microscopy measurements of fluorescein-conjugated gold nanorods in solution, as well as inserted in solid tissue-imitating phantoms. A lack of consistency between the fluorescence lifetime results of the solutions and the phantoms raises a question about the ability of tissue-like phantoms to mai...

  20. NEMA image quality phantom measurements and attenuation correction in integrated PET/MR hybrid imaging.

    Science.gov (United States)

    Ziegler, Susanne; Jakoby, Bjoern W; Braun, Harald; Paulus, Daniel H; Quick, Harald H

    2015-12-01

    In integrated PET/MR hybrid imaging the evaluation of PET performance characteristics according to the NEMA standard NU 2-2007 is challenging because of incomplete MR-based attenuation correction (AC) for phantom imaging. In this study, a strategy for CT-based AC of the NEMA image quality (IQ) phantom is assessed. The method is systematically evaluated in NEMA IQ phantom measurements on an integrated PET/MR system. NEMA IQ measurements were performed on the integrated 3.0 Tesla PET/MR hybrid system (Biograph mMR, Siemens Healthcare). AC of the NEMA IQ phantom was realized by an MR-based and by a CT-based method. The suggested CT-based AC uses a template μ-map of the NEMA IQ phantom and a phantom holder for exact repositioning of the phantom on the systems patient table. The PET image quality parameters contrast recovery, background variability, and signal-to-noise ratio (SNR) were determined and compared for both phantom AC methods. Reconstruction parameters of an iterative 3D OP-OSEM reconstruction were optimized for highest lesion SNR in NEMA IQ phantom imaging. Using a CT-based NEMA IQ phantom μ-map on the PET/MR system is straightforward and allowed performing accurate NEMA IQ measurements on the hybrid system. MR-based AC was determined to be insufficient for PET quantification in the tested NEMA IQ phantom because only photon attenuation caused by the MR-visible phantom filling but not the phantom housing is considered. Using the suggested CT-based AC, the highest SNR in this phantom experiment for small lesions (PET/MR hybrid system. The superiority of CT-based AC for this phantom is demonstrated by comparison to measurements using MR-based AC. Furthermore, optimized PET image reconstruction parameters are provided for the highest lesion SNR in NEMA IQ phantom measurements.

  1. Use of Calcitonin in Recalcitrant Phantom Limb Pain Complicated by Heterotopic Ossification

    Directory of Open Access Journals (Sweden)

    Ricardo Viana

    2015-01-01

    Full Text Available A common complication following amputation is phantom sensation, which may include experiencing pain in the phantom limb. This study details the management of phantom limb pain in a 72-year-old man, in whom comorbid heterotopic ossification was present. In addition, the authors provide a review of the literature regarding phantom limb pain management, and summarize the current understanding of heterotopic ossification and its possible link to peripheral nerve injury.

  2. "Imprisoned" in pain: analyzing personal experiences of phantom pain.

    Science.gov (United States)

    Nortvedt, Finn; Engelsrud, Gunn

    2014-11-01

    This article explores the phenomenon of "phantom pain." The analysis is based on personal experiences elicited from individuals who have lost a limb or live with a paralyzed body part. Our study reveals that the ways in which these individuals express their pain experience is an integral aspect of that experience. The material consists of interviews undertaken with men who are living with phantom pain resulting from a traumatic injury. The phenomenological analysis is inspired by Zahavi (J Conscious Stud 8(5-7):151-167, 2001) and Merleau-Ponty (Phenomenology of perception. Routledge and Kegan Paul, London, 1962/2000). On a descriptive level the metaphors these patients invoke to describe their condition reveal immense suffering, such as a feeling of being invaded by insects or of their skin being scorched and stripped from their body. Such metaphors express a dimension of experience concerning the self that is in pain and others whom the sufferer relates to through this pain, as well as the agony that this pain inflicts in the world of lived experience. This pain has had a profound impact on their lives and altered their relationship with self (body), others and the world. Their phantom pain has become a reminder of their formerly intact and functioning body; they describe the contrast between their past and present body as an ambiguous and disturbing experience. We conclude that these sensitive and personalized experiences of phantom pain illuminates how acts of expression--spoken pain--constitute a fundamental dimension of a first-person perspective which contribute to the field of knowledge about "phantom pain".

  3. MRI characteristics for "phantom" scratching in canine syringomyelia.

    Science.gov (United States)

    Nalborczyk, Zoe R; McFadyen, Angus K; Jovanovik, Jelena; Tauro, Anna; Driver, Colin J; Fitzpatrick, Noel; Knower, Susan P; Rusbridge, Clare

    2017-11-16

    A classic sign of canine syringomyelia (SM) is scratching towards one shoulder. Using magnetic resonance imaging (MRI) we investigate the spinal cord lesion relating to this phenomenon which has characteristics similar to fictive scratch secondary to spinal cord transection. Medical records were searched for Cavalier King Charles spaniels with a clinical and MRI diagnosis of symptomatic SM associated with Chiari-like malformation (CM). The cohort was divided into SM with phantom scratching (19 dogs) and SM but no phantom scratching (18 dogs). MRI files were anonymised, randomised and viewed in EFILM ™. For each transverse image, the maximum perpendicular dimensions of the syrinx in the dorsal spinal cord quadrants were determined. Visual assessment was made as to whether the syrinx extended to the superficial dorsal horn (SDH). We showed that phantom scratching appears associated with a large dorsolateral syrinx that extends to the SDH in the C3-C6 spinal cord segments (corresponding to C2-C5 vertebrae). Estimated dorsal quadrant syrinx sizes based on the perpendicular diameters were between 2.5 and 9.5 times larger in dogs with phantom scratching, with the largest mean difference p-value being 0.009. SM associated phantom scratching appears associated with MRI findings of a large syrinx extending into the mid cervical SDH. We hypothesise that damage in this region might influence the lumbosacral scratching central pattern generator (CPG). If a scratching SM affected dog does not have a large dorsolateral cervical syrinx with SDH involvement then alternative explanations for scratching should be investigated.

  4. Posttraumatic syringomyelia: volumetric phantom and patient studies using MR imaging

    Energy Technology Data Exchange (ETDEWEB)

    Freund, Michael; Habicht, Dirk; Kalvine, Kira; Sartor, Klaus [Department of Neuroradiology, Medical School, University of Heidelberg (Germany); Aschoff, Alfred [Department of Neurosurgery, Medical School, University of Heidelberg (Germany)

    2002-12-01

    The purpose of this study was to determine the volume of posttraumatic syringomyelia (PTS) based on standard MRI data acquisitions, and to compare the volumes with the neurological deficits of the patients. Firstly, phantom studies were performed using routine T1- (T1W; TR 500 ms, TE 13 ms) spin-echo (SE) images, 3D gradient-echo (GE) images and T2-weighted (T2W) turbo spin-echo (TSE) images (TR 3000 ms, TE 130 ms), in the sagittal plane. The slices were interleaved so that there was no gap. Twelve phantoms simulating a PTS were constructed and filled with fluid. Each volume was exactly measured immediately prior to filling (volumes: 3600-74,000 mm{sup 3}, mean 27,500 mm{sup 3}). In the clinical study 32 patients with PTS were examined using the same protocol. Patients were supine and a phased-array coil was used. The phantom studies revealed measurement errors of within 35%. There were problems defining the boundaries in the small and irregular phantoms as well as in small and irregular PTS, and due to the partial-volume averaging effect. The two small irregular phantoms could only be measured on the axial images. The T2W images in the axial plane showed the best results: measurement accuracy 92%. In the clinical study all examinations were technically successful. The volumes of the PTS ranged between 200 and 19,800 mm{sup 3}; the mean volume was 4075 mm{sup 3}. Our initial results show that the volume measurement of a PTS using standard MRI sequences can help generate more objective and accurate measures of spinal cord lesions, and this may enhance the sensitivity of MRI in detecting disease progression or regression after treatment. (orig.)

  5. Internal dosimetry estimates using voxelized reference phantoms for thyroid agents.

    Science.gov (United States)

    Hoseinian-Azghadi, E; Rafat-Motavalli, L; Miri-Hakimabad, H

    2014-05-01

    This work presents internal dosimetry estimates for diagnostic procedures performed for thyroid disorders by relevant radiopharmaceuticals. The organ doses for (131)Iodine, (123)Iodine and (99m)Tc incorporated into the body were calculated for the International Commission on Radiological Protection (ICRP) reference voxel phantoms using the Monte Carlo transport method. A comparison between different thyroid uptakes of iodine in the range of 0-55% was made, and the effect of various techniques for administration of (99m)Tc on organ doses was studied. To investigate the necessity of calculating organ dose from all source regions, the major source organ and its contribution to total dose were specified for each target organ. Moreover, we compared effective dose in ICRP voxel phantoms with that in stylized phantoms. In our method, we directly calculated the organ dose without using the S values or SAFs, as is commonly done. Hence, a distribution of the absorbed dose to entire tissues was obtained. The chord length distributions (CLDs) were also computed for the selected source-target pairs to make comparison across the genders. The results showed that the S values for radionuclides in the thyroid are not sufficient for calculating the organ doses, especially for (123)I and (99m)Tc. The thyroid and its neighboring organs receive a greater dose as thyroid uptake increases. Our comparisons also revealed an underestimation of organ doses reported for the stylized phantoms compared with the values based on the ICRP voxel phantoms in the uptake range of 5-55%, and an overestimation of absorbed dose by up to 2-fold for Iodine administration using blocking agent and for (99m)Tc incorporation.

  6. Developing a Verification and Training Phantom for Gynecological Brachytherapy System

    Directory of Open Access Journals (Sweden)

    Mahbobeh Nazarnejad

    2012-03-01

    Full Text Available Introduction Dosimetric accuracy is a major issue in the quality assurance (QA program for treatment planning systems (TPS. An important contribution to this process has been a proper dosimetry method to guarantee the accuracy of delivered dose to the tumor. In brachytherapy (BT of gynecological (Gyn cancer it is usual to insert a combination of tandem and ovoid applicators with a complicated geometry which makes their dosimetry verification difficult and important. Therefore, evaluation and verification of dose distribution is necessary for accurate dose delivery to the patients. Materials and Methods The solid phantom was made from Perspex slabs as a tool for intracavitary brachytherapy dosimetric QA. Film dosimetry (EDR2 was done for a combination of ovoid and tandem applicators introduced by Flexitron brachytherapy system. Treatment planning was also done with Flexiplan 3D-TPS to irradiate films sandwiched between phantom slabs. Isodose curves obtained from treatment planning system and the films were compared with each other in 2D and 3D manners. Results The brachytherapy solid phantom was constructed with slabs. It was possible to insert tandems and ovoids loaded with radioactive source of Ir-192 subsequently. Relative error was 3-8.6% and average relative error was 5.08% in comparison with the films and TPS isodose curves. Conclusion Our results showed that the difference between TPS and the measurements is well within the acceptable boundaries and below the action level according to AAPM TG.45. Our findings showed that this phantom after minor corrections can be used as a method of choice for inter-comparison analysis of TPS and to fill the existing gap for accurate QA program in intracavitary brachytherapy. The constructed phantom also showed that it can be a valuable tool for verification of accurate dose delivery to the patients as well as training for brachytherapy residents and physics students.

  7. Validation of Cooper's ligament thickness in software breast phantoms

    Science.gov (United States)

    Kuperavage, Adam J.; Imran, Abdullah-Al-Zubaer; Bakic, Predrag R.; Maidment, Andrew; Pokrajac, David D.

    2017-03-01

    Anthropomorphic breast phantoms are important tools for a wide range of tasks including pre-clinical validation of novel imaging techniques. In order to improve the realism in the phantoms, assessment of simulated anatomical structures is crucial. Thickness of simulated Cooper's ligaments influences the percentage of dense tissue, as well as qualitative and quantitative properties of simulated images. We introduce three methods (2-dimensional watershed, 3-dimensional watershed, and facet counting) to assess the thickness of the simulated Cooper's ligaments in the breast phantoms. For the validation of simulated phantoms, the thickness of ligaments has been measured and compared with the input thickness values. These included a total of 64 phantoms with nominal ligament thicknesses of 200, 400, 600, and 800 μm. The 2-dimensional and 3-dimensional watershed transformations were performed to obtain the median skeleton of the ligaments. In the 2-dimensional watershed, the median skeleton was found cross-section by cross-section, while the skeleton was found for the entire 3-dimensional space in the 3-dimensional watershed. The thickness was calculated by taking the ratio of the total volume of ligaments and the volume of median skeleton. In the facet counting method, the ligament thickness was estimated as a ratio between estimated ligaments' volume and average ligaments' surface area. We demonstrated that the 2-dimensional watershed technique overestimates the ligament thickness. Good agreement was found between the facet counting technique and the 3-dimensional watershed for assessing thickness. The proposed techniques are applicable for ligaments' thickness estimation on clinical breast images, provided segmentation of Cooper's ligaments has been performed.

  8. Evaluation of tomosynthesis elastography in a breast-mimicking phantom

    Energy Technology Data Exchange (ETDEWEB)

    Engelken, Florian Jan, E-mail: florian.engelken@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Sack, Ingolf, E-mail: ingolf.sack@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Klatt, Dieter, E-mail: dieter.klatt@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Fischer, Thomas, E-mail: thom.fischer@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Fallenberg, Eva Maria, E-mail: eva.fallenberg@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Bick, Ulrich, E-mail: ulrich.bick@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany); Diekmann, Felix, E-mail: felix.diekmann@charite.de [Department of Radiology, Charité Universitätsmedizin Berlin, Charitéplatz 1, 10117 Berlin (Germany)

    2012-09-15

    Objective: To evaluate whether measurement of strain under static compression in tomosynthesis of a breast-mimicking phantom can be used to distinguish tumor-simulating lesions of different elasticities and to compare the results to values predicted by rheometric analysis as well as results of ultrasound elastography. Materials and methods: We prepared three soft breast-mimicking phantoms containing simulated tumors of different elasticities. The phantoms were imaged using a wide angle tomosynthesis system with increasing compression settings ranging from 0 N to 105 N in steps of 15 N. Strain of the inclusions was measured in two planes using a commercially available mammography workstation. The elasticity of the phantom matrix and inclusion material was determined by rheometric analysis. Ultrasound elastography of the inclusions was performed using two different ultrasound elastography algorithms. Results: Strain at maximal compression was 24.4%/24.5% in plane 1/plane 2, respectively, for the soft inclusion, 19.6%/16.9% for the intermediate inclusion, and 6.0%/10.2% for the firm inclusion. The strain ratios predicted by rheometrical testing were 0.41, 0.83 and 1.26 for the soft, intermediate, and firm inclusions, respectively. The strain ratios obtained for the soft, intermediate, and firm inclusions were 0.72 ± 0.13, 1.02 ± 0.21 and 2.67 ± 1.70, respectively for tomosynthesis elastography, 0.91, 1.64 and 2.07, respectively, for ultrasound tissue strain imaging, and 0.97, 2.06 and 2.37, respectively, for ultrasound real-time elastography. Conclusions: Differentiation of tumor-simulating inclusions by elasticity in a breast mimicking phantom may be possible by measuring strain in tomosynthesis. This method may be useful for assessing elasticity of breast lesions tomosynthesis of the breast.

  9. Heterogeneous Anthropomorphic Phantoms with Realistic Dielectric Properties for Microwave Breast Imaging Experiments

    OpenAIRE

    Mashal, Alireza; Gao, Fuqiang; Hagness, Susan C.

    2011-01-01

    We present a technique for fabricating realistic breast phantoms for microwave imaging experiments. Using oil-in-gelatin dispersions that mimic breast tissue dielectric properties at microwave frequencies, we constructed four heterogeneous phantoms spanning the full range of volumetric breast densities. We performed CT scans and dielectric properties measurements to characterize each phantom.

  10. Experimental and computational development of a natural breast phantom for dosimetry studies

    Energy Technology Data Exchange (ETDEWEB)

    Nogueira, Luciana B.; Campos, Tarcisio P.R., E-mail: lucibn19@yahoo.com.br [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil)

    2013-07-01

    This paper describes the experimental and computational development of a natural breast phantom, anthropomorphic and anthropometric for studies in dosimetry of brachytherapy and teletherapy of breast. The natural breast phantom developed corresponding to fibroadipose breasts of women aged 30 to 50 years, presenting radiographically medium density. The experimental breast phantom was constituted of three tissue-equivalents (TE's): glandular TE, adipose TE and skin TE. These TE's were developed according to chemical composition of human breast and present radiological response to exposure. Completed the construction of experimental breast phantom this was mounted on a thorax phantom previously developed by the research group NRI/UFMG. Then the computational breast phantom was constructed by performing a computed tomography (CT) by axial slices of the chest phantom. Through the images generated by CT a computational model of voxels of the thorax phantom was developed by SISCODES computational program, being the computational breast phantom represented by the same TE's of the experimental breast phantom. The images generated by CT allowed evaluating the radiological equivalence of the tissues. The breast phantom is being used in studies of experimental dosimetry both in brachytherapy as in teletherapy of breast. Dosimetry studies by MCNP-5 code using the computational model of the phantom breast are in progress. (author)

  11. Solid anthropomorphic infant whole body DXA phantom: Design, evaluation, and multisite testing

    Science.gov (United States)

    Dual energy X-ray absorptiometry (DXA) requires phantoms for quality control and cross-calibration. No commercially available phantoms are designed specifically for infant whole-body scanning. We fabricated a phantom closely matching a 7-kg human infant in body habitus using PVC, nylon-mix, and poly...

  12. Atypical supernumerary phantom limb and phantom limb pain in a patient with spinal cord injury: case report.

    Science.gov (United States)

    Choi, Ja Young; Kim, Hyo In; Lee, Kil Chan; Han, Zee-A

    2013-12-01

    Supernumerary phantom limb (SPL) resulting from spinal cord lesions are very rare, with only sporadic and brief descriptions in the literature. Furthermore, the reported cases of SPL typically occurred in neurologically incomplete spinal cord patients. Here, we report a rare case of SPL with phantom limb pain that occurred after traumatic spinal cord injury in a neurologically complete patient. After a traffic accident, a 43-year-old man suffered a complete spinal cord injury with a C6 neurologic level of injury. SPL and associated phantom limb pain occurred 6 days after trauma onset. The patient felt the presence of an additional pair of legs that originated at the hip joints and extended medially, at equal lengths to the paralyzed legs. The intensity of SPL and associated phantom limb pain subsequently decreased after visual-tactile stimulation treatment, in which the patient visually identified the paralyzed limbs and then gently tapped them with a wooden stick. This improvement continued over the 2 months of inpatient treatment at our hospital and the presence of the SPLs was reduced to 20% of the real paralyzed legs. This is the first comprehensive report on SPLs of the lower extremities after neurologically complete spinal cord injury.

  13. Atypical Supernumerary Phantom Limb and Phantom Limb Pain in a Patient With Spinal Cord Injury: Case Report

    Science.gov (United States)

    Choi, Ja Young; Kim, Hyo In; Lee, Kil Chan

    2013-01-01

    Supernumerary phantom limb (SPL) resulting from spinal cord lesions are very rare, with only sporadic and brief descriptions in the literature. Furthermore, the reported cases of SPL typically occurred in neurologically incomplete spinal cord patients. Here, we report a rare case of SPL with phantom limb pain that occurred after traumatic spinal cord injury in a neurologically complete patient. After a traffic accident, a 43-year-old man suffered a complete spinal cord injury with a C6 neurologic level of injury. SPL and associated phantom limb pain occurred 6 days after trauma onset. The patient felt the presence of an additional pair of legs that originated at the hip joints and extended medially, at equal lengths to the paralyzed legs. The intensity of SPL and associated phantom limb pain subsequently decreased after visual-tactile stimulation treatment, in which the patient visually identified the paralyzed limbs and then gently tapped them with a wooden stick. This improvement continued over the 2 months of inpatient treatment at our hospital and the presence of the SPLs was reduced to 20% of the real paralyzed legs. This is the first comprehensive report on SPLs of the lower extremities after neurologically complete spinal cord injury. PMID:24466528

  14. Primary motor cortex changes after amputation correlate with phantom limb pain and the ability to move the phantom limb.

    Science.gov (United States)

    Raffin, Estelle; Richard, Nathalie; Giraux, Pascal; Reilly, Karen T

    2016-04-15

    A substantial body of evidence documents massive reorganization of primary sensory and motor cortices following hand amputation, the extent of which is correlated with phantom limb pain. Many therapies for phantom limb pain are based upon the idea that plastic changes after amputation are maladaptive and attempt to normalize representations of cortical areas adjacent to the hand area. Recent data suggest, however, that higher levels of phantom pain are associated with stronger local activity and more structural integrity in the missing hand area rather than with reorganization of neighbouring body parts. While these models appear to be mutually exclusive they could co-exist, and one reason for the apparent discrepancy between them might be that no single study has examined the organisation of lip, elbow, and hand movements in the same participants. In this study we thoroughly examined the 3D anatomy of the central sulcus and BOLD responses during movements of the hand, elbow, and lips using MRI techniques in 11 upper-limb amputees and 17 healthy control subjects. We observed different reorganizational patterns for all three body parts as the former hand area showed few signs of reorganization, but the lip and elbow representations reorganized and shifted towards the hand area. We also found that poorer voluntary control and higher levels of pain in the phantom limb were powerful drivers of the lip and elbow topological changes. In addition to providing further support for the maladaptative plasticity model, we demonstrate for the first time that motor capacities of the phantom limb correlate with post-amputation reorganization, and that this reorganization is not limited to the face and hand representations but also includes the proximal upper-limb. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Organ shielding and doses in Low-Earth orbit calculated for spherical and anthropomorphic phantoms

    Science.gov (United States)

    Matthiä, Daniel; Berger, Thomas; Reitz, Günther

    2013-08-01

    Humans in space are exposed to elevated levels of radiation compared to ground. Different sources contribute to the total exposure with galactic cosmic rays being the most important component. The application of numerical and anthropomorphic phantoms in simulations allows the estimation of dose rates from galactic cosmic rays in individual organs and whole body quantities such as the effective dose. The male and female reference phantoms defined by the International Commission on Radiological Protection and the hermaphrodite numerical RANDO phantom are voxel implementations of anthropomorphic phantoms and contain all organs relevant for radiation risk assessment. These anthropomorphic phantoms together with a spherical water phantom were used in this work to translate the mean shielding of organs in the different anthropomorphic voxel phantoms into positions in the spherical phantom. This relation allows using a water sphere as surrogate for the anthropomorphic phantoms in both simulations and measurements. Moreover, using spherical phantoms in the calculation of radiation exposure offers great advantages over anthropomorphic phantoms in terms of computational time. In this work, the mean shielding of organs in the different voxel phantoms exposed to isotropic irradiation is presented as well as the corresponding depth in a water sphere. Dose rates for Low-Earth orbit from galactic cosmic rays during solar minimum conditions were calculated using the different phantoms and are compared to the results for a spherical water phantom in combination with the mean organ shielding. For the spherical water phantom the impact of different aluminium shielding between 1 g/cm2 and 100 g/cm2 was calculated. The dose equivalent rates were used to estimate the effective dose rate.

  16. A suitability study of the fission product phantom and the bottle manikin absorption phantom for calibration of in vivo bioassay equipment for the DOELAP accreditation testing program

    Energy Technology Data Exchange (ETDEWEB)

    Olsen, P.C.; Lynch, T.P.

    1991-08-01

    Pacific Northwest laboratory (PNL) conducted an intercomparison study of the Fission Product phantom and the bottle manikin absorption (BOMAB) phantom for the US Department of Energy (DOE) to determine the consistency of calibration response of the two phantoms and their suitability for certification and use under a planned bioassay laboratory accreditation program. The study was initiated to determine calibration factors for both types of phantoms and to evaluate the suitability of their use in DOE Laboratory Accreditation Program (DOELAP) round-robin testing. The BOMAB was found to be more appropriate for the DOELAP testing program. 9 refs., 9 figs., 9 tabs.

  17. Construction of mammography phantoms with a 3D printer and tested with a TIMEPIX system

    Science.gov (United States)

    Calderón-García, J. S.; Roque, G. A.; Ávila, C. A.

    2017-11-01

    We present a new mammography phantom made of hydroxyapatite crystals with different sizes and shapes, to emulate anthropomorphic microcalcifications, which we locate at different depths of a PMMA embedding material. The aim of the phantom presented is to address some issues of the standard commercial ones that are being used for comparing 3D vs 2D mammography systems. We present X-ray images, taken under the same conditions, for both a commercial phantom and the new proposed phantom. We compare signal to noise ratios (SNR) obtained for both cases. This phantom has been constructed to be easily assembled within different configurations to emulate modified features that might be of medical interest.

  18. Early and effective use of ketamine for treatment of phantom limb pain

    Directory of Open Access Journals (Sweden)

    Harsha Shanthanna

    2010-01-01

    Full Text Available Treatment for phantom limb pain is difficult and challenging. There is often suboptimum treatment with fewer than 10% receiving lasting relief. Treatments based broadly on other neuropathic pains may not be appropriate for a clinical success. We report a case of phantom limb pain, which proved resistant to multiple analgesics, including opioids and continuous epidural blockade. Treatment with intravenous (IV ketamine as an alternate day infusion, gave complete remission of phantom limb pain. This demonstrates an early and effective use of a potent NMDA antagonist for treatment of phantom limb pain. Mechanisms underlying phantom limb pain are briefly discussed.

  19. The UF family of reference hybrid phantoms for computational radiation dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choonsik [Division of Cancer Epidemiology and Genetics, National Cancer Institute, National Institute of Health, Bethesda, MD 20852 (United States); Lodwick, Daniel; Hurtado, Jorge; Pafundi, Deanna [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL 32611 (United States); Williams, Jonathan L [Department of Radiology, University of Florida, Gainesville, FL 32611 (United States); Bolch, Wesley E [Departments of Nuclear and Radiological and Biomedical Engineering, University of Florida, Gainesville, FL 32611 (United States)], E-mail: wbolch@ufl.edu

    2010-01-21

    Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms-those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR(TM). NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros(TM). The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference

  20. A versatile apparatus for two-dimensional atomtronic quantum simulation

    Science.gov (United States)

    Haase, T. A.; White, D. H.; Brown, D. J.; Herrera, I.; Hoogerland, M. D.

    2017-11-01

    We report on the implementation of a novel optical setup for generating high-resolution customizable potentials to address ultracold bosonic atoms in two dimensions. Two key features are developed for this purpose. The customizable potential is produced with a direct image of a spatial light modulator, conducted with an in-vacuum imaging system of high numerical aperture. Custom potentials are drawn over an area of 600 ×400 μ m with a resolution of 0.9 μm. The second development is a two-dimensional planar trap for atoms with an aspect ratio of 900 and spatial extent of Rayleigh range 1.6 × 1.6 mm, providing near-ballistic in-planar movement. We characterize the setup and present a brief catalog of experiments to highlight the versatility of the system.

  1. Algae biofuels: versatility for the future of bioenergy.

    Science.gov (United States)

    Jones, Carla S; Mayfield, Stephen P

    2012-06-01

    The world continues to increase its energy use, brought about by an expanding population and a desire for a greater standard of living. This energy use coupled with the realization of the impact of carbon dioxide on the climate, has led us to reanalyze the potential of plant-based biofuels. Of the potential sources of biofuels the most efficient producers of biomass are the photosynthetic microalgae and cyanobacteria. These versatile organisms can be used for the production of bioethanol, biodiesel, biohydrogen, and biogas. In fact, one of the most economic methods for algal biofuels production may be the combined biorefinery approach where multiple biofuels are produced from one biomass source. Copyright © 2011 Elsevier Ltd. All rights reserved.

  2. Extraordinary phylogenetic diversity and metabolic versatility in aquifer sediment.

    Science.gov (United States)

    Castelle, Cindy J; Hug, Laura A; Wrighton, Kelly C; Thomas, Brian C; Williams, Kenneth H; Wu, Dongying; Tringe, Susannah G; Singer, Steven W; Eisen, Jonathan A; Banfield, Jillian F

    2013-01-01

    Microorganisms in the subsurface represent a substantial but poorly understood component of the Earth's biosphere. Subsurface environments are complex and difficult to characterize; thus, their microbiota have remained as a 'dark matter' of the carbon and other biogeochemical cycles. Here we deeply sequence two sediment-hosted microbial communities from an aquifer adjacent to the Colorado River, CO, USA. No single organism represents more than ~1% of either community. Remarkably, many bacteria and archaea in these communities are novel at the phylum level or belong to phyla lacking a sequenced representative. The dominant organism in deeper sediment, RBG-1, is a member of a new phylum. On the basis of its reconstructed complete genome, RBG-1 is metabolically versatile. Its wide respiration-based repertoire may enable it to respond to the fluctuating redox environment close to the water table. We document extraordinary microbial novelty and the importance of previously unknown lineages in sediment biogeochemical transformations.

  3. A small low-power networked and versatile sensor interface

    Science.gov (United States)

    Vincent, Peter S.; McMahon, Phillip J.; Muscat, Richard F.; Zeve, Ladislav; Wilson, Alan R.

    2007-01-01

    Defence Science and Technology Organisation (DSTO) has developed a low power RS485 sensor network that can be hardware configured at design time from a number of modules, depending on its final application. The core predesigned module includes network communications, microprocessor control and digital input/output. A number of analogue sensor interface modules can easily be added to this core. In addition, the software is also of modular design consisting of a set of core operating routines and a set of routines for controlling sensor operations that can be downloaded or upgraded in the field. Prime consideration in this development has been given to the need for small size, low weight, low power and versatility of operation. The hardware is based around the Texas Instruments MSP430® micro-controller. This paper will present some of the considerations leading to the design and examples of applications of the sensor network.

  4. Preparation of a Versatile Bifunctional Zeolite for Targeted Imaging Applications

    Science.gov (United States)

    Ndiege, Nicholas; Raidoo, Renugan; Schultz, Michael K.; Larsen, Sarah

    2011-01-01

    Bifunctional zeolite Y was prepared for use in targeted in vivo molecular imaging applications. The strategy involved functionalization of the external surface of zeolite Y with chloropropyltriethoxysilane followed by reaction with sodium azide to form azide-functionalized NaY, which is amenable to copper(1) catalyzed click chemistry. In this study, a model alkyne (4-pentyn-1-ol) was attached to the azide-terminated surface via click chemistry to demonstrate feasibility for attachment of molecular targeting vectors (e.g., peptides, aptamers) to the zeolite surface. The modified particle efficiently incorporates the imaging radioisotope gallium-68 (68Ga) into the pores of the azide-functionalized NaY zeolite to form a stable bifunctional molecular targeting vector. The result is a versatile “clickable” zeolite platform that can be tailored for future in vivo molecular targeting and imaging modalities. PMID:21306141

  5. A new versatile in-process monitoring system for milling

    CERN Document Server

    Ritou, Mathieu; Furet, Benoît; Hascoët, Jean-Yves

    2013-01-01

    Tool condition monitoring (TCM) systems can improve productivity and ensure workpiece quality, yet, there is a lack of reliable TCM solutions for small-batch or one-off manufacturing of industrial parts. TCM methods which include the characteristics of the cut seem to be particularly suitable for these demanding applications. In the first section of this paper, three process-based indicators have been retrieved from literature dealing with TCM. They are analysed using a cutting force model and experiments are carried out in industrial conditions. Specific transient cuttings encountered during the machining of the test part reveal the indicators to be unreliable. Consequently, in the second section, a versatile in-process monitoring method is suggested. Based on experiments carried out under a range of different cutting conditions, an adequate indicator is proposed: the relative radial eccentricity of the cutters is estimated at each instant and characterizes the tool state. It is then compared with the previo...

  6. Microscale Symmetrical Electroporator Array as a Versatile Molecular Delivery System

    Science.gov (United States)

    Ouyang, Mengxing; Hill, Winfield; Lee, Jung Hyun; Hur, Soojung Claire

    2017-03-01

    Successful developments of new therapeutic strategies often rely on the ability to deliver exogenous molecules into cytosol. We have developed a versatile on-chip vortex-assisted electroporation system, engineered to conduct sequential intracellular delivery of multiple molecules into various cell types at low voltage in a dosage-controlled manner. Micro-patterned planar electrodes permit substantial reduction in operational voltages and seamless integration with an existing microfluidic technology. Equipped with real-time process visualization functionality, the system enables on-chip optimization of electroporation parameters for cells with varying properties. Moreover, the system’s dosage control and multi-molecular delivery capabilities facilitate intracellular delivery of various molecules as a single agent or in combination and its utility in biological research has been demonstrated by conducting RNA interference assays. We envision the system to be a powerful tool, aiding a wide range of applications, requiring single-cell level co-administrations of multiple molecules with controlled dosages.

  7. A versatile high resolution scanning tunneling potentiometry implementation.

    Science.gov (United States)

    Druga, T; Wenderoth, M; Homoth, J; Schneider, M A; Ulbrich, R G

    2010-08-01

    We have developed a new scanning tunneling potentiometry technique which can-with only minor changes of the electronic setup-be easily added to any standard scanning tunneling microscope (STM). This extension can be combined with common STM techniques such as constant current imaging or scanning tunneling spectroscopy. It is capable of performing measurements of the electrochemical potential with microvolt resolution. Two examples demonstrate the versatile application. First of all, we have determined local variations of the electrochemical potential due to charge transport of biased samples down to angstrom length scales. Second, with tip and sample at different temperatures we investigated the locally varying thermovoltage occurring at the tunneling junction. Aside from its use in determining the chemical identity of substances at the sample surface our method provides a controlled way to eliminate the influence of laterally varying thermovoltages on low-bias constant current topographies.

  8. Twister ribozymes as highly versatile expression platforms for artificial riboswitches.

    Science.gov (United States)

    Felletti, Michele; Stifel, Julia; Wurmthaler, Lena A; Geiger, Sophie; Hartig, Jörg S

    2016-09-27

    The utilization of ribozyme-based synthetic switches in biotechnology has many advantages such as an increased robustness due to in cis regulation, small coding space and a high degree of modularity. The report of small endonucleolytic twister ribozymes provides new opportunities for the development of advanced tools for engineering synthetic genetic switches. Here we show that the twister ribozyme is distinguished as an outstandingly flexible expression platform, which in conjugation with three different aptamer domains, enables the construction of many different one- and two-input regulators of gene expression in both bacteria and yeast. Besides important implications in biotechnology and synthetic biology, the observed versatility in artificial genetic control set-ups hints at possible natural roles of this widespread ribozyme class.

  9. Preliminary Options Assessment of Versatile Irradiation Test Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Sen, Ramazan Sonat [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2017-01-01

    The objective of this report is to summarize the work undertaken at INL from April 2016 to January 2017 and aimed at analyzing some options for designing and building a versatile test reactor; the scope of work was agreed upon with DOE-NE. Section 2 presents some results related to KNK II and PRISM Mod A. Section 3 presents some alternatives to the VCTR presented in [ ] as well as a neutronic parametric study to assess the minimum power requirement needed for a 235U metal fueled fast test reactor capable to generate a fast (>100 keV) flux of 4.0 x 1015 n /cm2-s at the test location. Section 4 presents some results regarding a fundamental characteristic of test reactors, namely displacement per atom (dpa) in test samples. Section 5 presents the INL assessment of the ANL fast test reactor design FASTER. Section 6 presents a summary.

  10. A versatile computer-controlled high-resolution LBIC system

    Energy Technology Data Exchange (ETDEWEB)

    Martin, J.; Fernandez-Lorenzo, C.; Poce-Fatou, J.A.; Alcantara, R. [Facultad de Ciencias, Cadiz (Spain). Dpto. de Quimica Fisica

    2004-07-01

    This paper presents the design of versatile equipment for obtaining laser-beam-induced current (LBIC) images which allows the study of large surfaces as well as conversion areas of a few micrometers. The modular optomechanical design enables the user to modify the size of the irradiation spot by simply changing the microscope objective used as focal lens, albeit within the limits set by the wavelength. The use of an appropriate calculation algorithm makes it possible to rely on a computerized system to adjust the distance at which the focusing lens must be placed with respect to the sample plane. The possibility of working at micrometer resolution allows one to obtain very significant information for the study of irregularities, manufacturing defects, impurities, grain boundaries, dislocations, recombination centers, etc. in photovoltaic wafers. (author)

  11. ggseqlogo: a versatile R package for drawing sequence logos.

    Science.gov (United States)

    Wagih, Omar

    2017-11-15

    Sequence logos have become a crucial visualization method for studying underlying sequence patterns in the genome. Despite this, there remains a scarcity of software packages that provide the versatility often required for such visualizations. ggseqlogo is an R package built on the ggplot2 package that aims to address this issue. ggseqlogo offers native illustration of publication-ready DNA, RNA and protein sequence logos in a highly customizable fashion with features including multi-logo plots, qualitative and quantitative colour schemes, annotation of logos and integration with other plots. The package is intuitive to use and seamlessly integrates into R analysis pipelines. ggseqlogo is released under the GNU licence and is freely available via CRAN-The Comprehensive R Archive Network https://cran.r-project.org/web/packages/ggseqlogo. A detailed tutorial can be found at https://omarwagih.github.io/ggseqlogo. wagih@ebi.ac.uk.

  12. Metagenome of a versatile chemolithoautotroph from expanding oceanic dead zones.

    Science.gov (United States)

    Walsh, David A; Zaikova, Elena; Howes, Charles G; Song, Young C; Wright, Jody J; Tringe, Susannah G; Tortell, Philippe D; Hallam, Steven J

    2009-10-23

    Oxygen minimum zones, also known as oceanic "dead zones," are widespread oceanographic features currently expanding because of global warming. Although inhospitable to metazoan life, they support a cryptic microbiota whose metabolic activities affect nutrient and trace gas cycling within the global ocean. Here, we report metagenomic analyses of a ubiquitous and abundant but uncultivated oxygen minimum zone microbe (SUP05) related to chemoautotrophic gill symbionts of deep-sea clams and mussels. The SUP05 metagenome harbors a versatile repertoire of genes mediating autotrophic carbon assimilation, sulfur oxidation, and nitrate respiration responsive to a wide range of water-column redox states. Our analysis provides a genomic foundation for understanding the ecological and biogeochemical role of pelagic SUP05 in oxygen-deficient oceanic waters and its potential sensitivity to environmental changes.

  13. Towards Versatile Robots Through Open Heterogeneous Modular Robots

    DEFF Research Database (Denmark)

    Lyder, Andreas

    Robots are important tools in our everyday life. Both in industry and at the consumer level they serve the purpose of increasing our scope and extending our capabilities. Modular robots take the next step, allowing us to easily create and build various robots from a set of modules. If a problem...... arises, a new robot can be assembled rapidly from the existing modules, in contrast to conventional robots, which require a time consuming and expensive development process. In this thesis we define a modular robot to be a robot consisting of dynamically reconfigurable modules. The goal of this thesis...... is to increase the versatility and practical usability of modular robots by introducing new conceptual designs. Until now modular robots have been based on a pre-specified set of modules, and thus, their functionality is limited. We propose an open heterogeneous design concept, which allows a modular robot...

  14. Grinder: a versatile amplicon and shotgun sequence simulator.

    Science.gov (United States)

    Angly, Florent E; Willner, Dana; Rohwer, Forest; Hugenholtz, Philip; Tyson, Gene W

    2012-07-01

    We introduce Grinder (http://sourceforge.net/projects/biogrinder/), an open-source bioinformatic tool to simulate amplicon and shotgun (genomic, metagenomic, transcriptomic and metatranscriptomic) datasets from reference sequences. This is the first tool to simulate amplicon datasets (e.g. 16S rRNA) widely used by microbial ecologists. Grinder can create sequence libraries with a specific community structure, α and β diversities and experimental biases (e.g. chimeras, gene copy number variation) for commonly used sequencing platforms. This versatility allows the creation of simple to complex read datasets necessary for hypothesis testing when developing bioinformatic software, benchmarking existing tools or designing sequence-based experiments. Grinder is particularly useful for simulating clinical or environmental microbial communities and complements the use of in vitro mock communities.

  15. The versatile subepithelial connective tissue graft: a literature update.

    Science.gov (United States)

    Karthikeyan, B V; Khanna, Divya; Chowdhary, Kamedh Yashawant; Prabhuji, M Lv

    2016-01-01

    Harmony between hard and soft tissue morphologies is essential for form, function, and a good esthetic outlook. Replacement grafts for correction of soft tissue defects around the teeth have become important to periodontal plastic and implant surgical procedures. Among a multitude of surgical techniques and graft materials reported in literature, the subepithelial connective tissue graft (SCTG) has gained wide popularity and acceptance. The purpose of this article is to acquaint clinicians with the current understanding of the versatile SCTG. Key factors associated with graft harvesting as well as applications, limitations, and complications of SCTGs are discussed. This connective tissue has shown excellent short- and long-term stability, is easily available, and is economical to use. The SCTG should be considered as an alternative in all periodontal reconstruction surgeries.

  16. Versatile and nondestructive photochemical process for biomolecule immobilization.

    Science.gov (United States)

    Viel, Pascal; Walter, Justine; Bellon, Sophie; Berthelot, Thomas

    2013-02-12

    Covalent immobilization of unmodified biological materials as proteins has been performed through a one-step and soft method. This process is based on a polyazidophenylene layer derived from the electroreduction of the parent salt 4-azidobenzenediazonium tetrafluoborate on gold substrates. The wavelength used (365 nm) for the photochemical grafting of a large variety of molecules as biomolecules is a key point to this nondestructive immobilization method. This simple process is also versatile and could be used for covalently binding a wide range of molecules such as polyethylene glycol moieties, for example. To validate this approach for biochip or microarray fabrication, a surface plasmon resonance imaging (SPRi) platform for immobilization of various antibody families was created by grafting G-protein through this process. This SPRi antibodies platform was tested with several consecutive cycles of antigen injections/regeneration steps without loss of activity.

  17. Versatility of PEEK as a fixed partial denture framework

    Directory of Open Access Journals (Sweden)

    Nikita Sinha

    2017-01-01

    Full Text Available Materials used for fixed partial denture (FPD frameworks have had properties of excellent strength, durability, and biocompatibility. Some of the materials which have been used till date include alloys, ceramics, and high-performance polymers such as zirconia, Ni–Cr, lithium disilicate, and so on. All these, though excellent, have their advantages and disadvantages. Hence, the search has always been on for a better material. One such material, which has made its foray into dentistry in the recent times, is polyetheretherketone (PEEK. It is a semicrystalline thermoplastic material. PEEK has an excellent chemical resistance and mechanical properties that are retained at high temperatures. The versatility of PEEK as a dental material for FPD framework was evaluated in this case report.

  18. The Versatile Extended Thoracodorsal Artery Perforator Flap for Breast Reconstruction

    DEFF Research Database (Denmark)

    Jacobs, Jordan; Børsen-Koch, Mikkel; Gunnarsson, Gudjon Leifur

    2015-01-01

    BACKGROUND: The thoracodorsal artery perforator (TAP) flap is a versatile tool that can be used to reconstruct the breast. The authors use preoperative perforator mapping using color Doppler ultrasonography and present a safe, efficient harvesting technique to demonstrate reliable use of the TAP...... flap in reconstructive surgery. METHODS: A multicenter, retrospective review was performed on all patients undergoing TAP flap reconstruction from August 2011 to November 2014. Data were collected from patient records as well as outpatient interviews. RESULTS: A total of 106 TAP flaps were performed...... complications occurred in 10 of 106 (10%) cases and included hematoma (1/108), venous congestion (2/108), and partial flap necrosis (7/108). The reconstructive goal was achieved in 103 of 106 (97%) flaps. CONCLUSIONS: The TAP flap is a pedicled, fasciocutaneous flap that can be used for total breast...

  19. Metagenome of a Versatile Chemolithoautotroph from Expanding Oceanic Dead Zones

    Energy Technology Data Exchange (ETDEWEB)

    Walsh, David A.; Zaikova, Elena; Howes, Charles L.; Song, Young; Wright, Jody; Tringe, Susannah G.; Tortell, Philippe D.; Hallam, Steven J.

    2009-07-15

    Oxygen minimum zones (OMZs), also known as oceanic"dead zones", are widespread oceanographic features currently expanding due to global warming and coastal eutrophication. Although inhospitable to metazoan life, OMZs support a thriving but cryptic microbiota whose combined metabolic activity is intimately connected to nutrient and trace gas cycling within the global ocean. Here we report time-resolved metagenomic analyses of a ubiquitous and abundant but uncultivated OMZ microbe (SUP05) closely related to chemoautotrophic gill symbionts of deep-sea clams and mussels. The SUP05 metagenome harbors a versatile repertoire of genes mediating autotrophic carbon assimilation, sulfur-oxidation and nitrate respiration responsive to a wide range of water column redox states. Thus, SUP05 plays integral roles in shaping nutrient and energy flow within oxygen-deficient oceanic waters via carbon sequestration, sulfide detoxification and biological nitrogen loss with important implications for marine productivity and atmospheric greenhouse control.

  20. A Versatile Active Block: DXCCCII and Tunable Applications

    Directory of Open Access Journals (Sweden)

    S. A. Tekin

    2014-12-01

    Full Text Available The study describes dual-X controlled current conveyor (DXCCCII as a versatile active block and its application to inductance simulators for testing. Moreover, the high pass filter application using with DXCCCII based inductance simulator and oscillator with flexible tunable oscillation frequency have been presented and simulated to confirm the theoretical validity. The proposed circuit which has a simple circuit design requires the low-voltage and the DXCCCII can also be tuned in the wide range by the biasing current. The proposed DXCCCII provides a good linearity, high output impedance at Z terminals, and a reasonable current and voltage transfer gain accuracy. The proposed DXCCCII and its applications have been simulated using the CMOS 0.18 µm technology.

  1. The human PDI family: Versatility packed into a single fold

    DEFF Research Database (Denmark)

    Appenzeller-Herzog, Christian; Ellgaard, Lars

    2007-01-01

    in promoting oxidative protein folding in the ER has been extended in recent years to include roles in other processes such as ER-associated degradation (ERAD), trafficking, calcium homeostasis, antigen presentation and virus entry. Some of these functions are performed by non-catalytic members of the family...... that lack the active-site cysteines. Regardless of their function, all human PDIs contain at least one domain of approximately 100 amino acid residues with structural homology to thioredoxin. As we learn more about the individual proteins of the family, a complex picture is emerging that emphasizes as much...... their differences as their similarities, and underlines the versatility of the thioredoxin fold. Here, we primarily explore the diversity of cellular functions described for the human PDIs. Udgivelsesdato: 2007-Dec-3...

  2. Submicron Lipid Emulsions: A Versatile Platform for Drug Delivery.

    Science.gov (United States)

    Zhang, Xingwang; Wu, Baojian

    2015-01-01

    Lipid emulsions have turned out to be a versatile tool for systemic delivery of poorly soluble drugs and cytotoxic drugs. Currently, the majority of marketed or developing drugs are recognized as BCS II and IV ones. How to solve the solubility and systemic administration that enables them access to clinical application is arising a great challenge in drug delivery systems. The key considerations for lipid emulsions are how to enhance the drug load, stability and reproducibility. Formulation and manufacture technique play the leading role in development of lipid emulsions. Understanding the biofate and characterization in vitro/vivo is suggestive to exploit the potential of lipid emulsions. This review discussed the manufacture techniques and in vivo behavior of lipid emulsions. Momentous interests were focused on their applications in drug delivery as well as the future evolution. Finally, we appreciated the methodologies of quality control and systemic risks associated with lipid emulsions.

  3. FLUTE: A versatile linac-based THz source

    Energy Technology Data Exchange (ETDEWEB)

    Nasse, M. J.; Schuh, M.; Schwarz, M. [Laboratory for Applications of Synchrotron Radiation (LAS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe (Germany); Naknaimueang, S.; Mathis, Y.-L.; Rossmanith, R.; Wesolowski, P.; Huttel, E. [ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Plech, A. [Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Schmelling, M. [Max Planck Institute for Nuclear Physics (MPIK), 69117 Heidelberg (Germany); Mueller, A.-S. [Laboratory for Applications of Synchrotron Radiation (LAS), Karlsruhe Institute of Technology (KIT), 76131 Karlsruhe (Germany); ANKA Synchrotron Radiation Facility, Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany); Institute for Photon Science and Synchrotron Radiation (IPS), Karlsruhe Institute of Technology (KIT), 76344 Eggenstein-Leopoldshafen (Germany)

    2013-02-15

    A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short ({approx}1 ps) THz pulses (up to {approx}4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range ({approx}100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

  4. FLUTE: a versatile linac-based THz source.

    Science.gov (United States)

    Nasse, M J; Schuh, M; Naknaimueang, S; Schwarz, M; Plech, A; Mathis, Y-L; Rossmanith, R; Wesolowski, P; Huttel, E; Schmelling, M; Müller, A-S

    2013-02-01

    A new compact versatile linear accelerator named FLUTE is currently being designed at the Karlsruhe Institute of Technology. This paper presents the status of this 42 MeV machine. It will be used to generate strong (several 100 MV/m) ultra-short (~1 ps) THz pulses (up to ~4-25 THz) for photon science experiments, as well as to conduct a variety of accelerator studies. The latter range from comparing different coherent THz radiation generation schemes to compressing electron bunches and studying the electron beam stability. The bunch charge will cover a wide range (~100 pC-3 nC). Later we plan to also produce ultra-short x-ray pulses from the electron bunches, which, for example, could then be combined for THz pump-x-ray probe experiments.

  5. Versatile RNA interference nanoplatform for systemic delivery of RNAs.

    Science.gov (United States)

    Choi, Ki Young; Silvestre, Oscar F; Huang, Xinglu; Min, Kyung Hyun; Howard, Gregory P; Hida, Naoki; Jin, Albert J; Carvajal, Nicole; Lee, Sang Wook; Hong, Jong-In; Chen, Xiaoyuan

    2014-05-27

    Development of nontoxic, tumor-targetable, and potent in vivo RNA delivery systems remains an arduous challenge for clinical application of RNAi therapeutics. Herein, we report a versatile RNAi nanoplatform based on tumor-targeted and pH-responsive nanoformulas (NFs). The NF was engineered by combination of an artificial RNA receptor, Zn(II)-DPA, with a tumor-targetable and drug-loadable hyaluronic acid nanoparticle, which was further modified with a calcium phosphate (CaP) coating by in situ mineralization. The NF can encapsulate small-molecule drugs within its hydrophobic inner core and strongly secure various RNA molecules (siRNAs, miRNAs, and oligonucleotides) by utilizing Zn(II)-DPA and a robust CaP coating. We substantiated the versatility of the RNAi nanoplatform by demonstrating effective delivery of siRNA and miRNA for gene silencing or miRNA replacement into different human types of cancer cells in vitro and into tumor-bearing mice in vivo by intravenous administration. The therapeutic potential of NFs coloaded with an anticancer drug doxorubicin (Dox) and multidrug resistance 1 gene target siRNA (siMDR) was also demonstrated in this study. NFs loaded with Dox and siMDR could successfully sensitize drug-resistant OVCAR8/ADR cells to Dox and suppress OVCAR8/ADR tumor cell proliferation in vitro and tumor growth in vivo. This gene/drug delivery system appears to be a highly effective nonviral method to deliver chemo- and RNAi therapeutics into host cells.

  6. Acrylonitrile Butadiene Styrene (ABS) plastic based low cost tissue equivalent phantom for verification dosimetry in IMRT.

    Science.gov (United States)

    Kumar, Rajesh; Sharma, S D; Deshpande, Sudesh; Ghadi, Yogesh; Shaiju, V S; Amols, H I; Mayya, Y S

    2009-12-17

    A novel IMRT phantom was designed and fabricated using Acrylonitrile Butadiene Styrene (ABS) plastic. Physical properties of ABS plastic related to radiation interaction and dosimetry were compared with commonly available phantom materials for dose measurements in radiotherapy. The ABS IMRT phantom has provisions to hold various types of detectors such as ion chambers, radiographic/radiochromic films, TLDs, MOSFETs, and gel dosimeters. The measurements related to pre-treatment dose verification in IMRT of carcinoma prostate were carried out using ABS and Scanditronics-Wellhoffer RW3 IMRT phantoms for five different cases. Point dose data were acquired using ionization chamber and TLD discs while Gafchromic EBT and radiographic EDR2 films were used for generating 2-D dose distributions. Treatment planning system (TPS) calculated and measured doses in ABS plastic and RW3 IMRT phantom were in agreement within +/-2%. The dose values at a point in a given patient acquired using ABS and RW3 phantoms were found comparable within 1%. Fluence maps and dose distributions of these patients generated by TPS and measured in ABS IMRT phantom were also found comparable both numerically and spatially. This study indicates that ABS plastic IMRT phantom is a tissue equivalent phantom and dosimetrically it is similar to solid/plastic water IMRT phantoms. Though this material is demonstrated for IMRT dose verification but it can be used as a tissue equivalent phantom material for other dosimetry purposes in radiotherapy.

  7. Study of homogeneity and inhomogeneity phantom in CUDA EGS for small field dosimetry

    Science.gov (United States)

    Yani, Sitti; Rhani, Mohamad Fahdillah; Haryanto, Freddy; Arif, Idam

    2017-02-01

    CUDA EGS was CUDA implementation to simulate transport photon in a material based on Monte Carlo algorithm for X-ray imaging. The objective of this study was to investigate the effect of inhomogeneities in inhomogeneity phantom for small field dosimetry (1×1, 2×2, 3×3, 4×4 and 5×5 cm2). Two phantoms, homogeneity and inhomogeneity phantom were used. The interaction in homogeneity and inhomogeneity phantom was dominated by Compton interaction and multiple scattering. The CUDA EGS can represent the inhomogeneity effect in small field dosimetry by combining the grayscale curve between homogeneity and inhomogeneity phantom. The grayscale curve in inhomogeneity phantom is not asymmetric because of the existence of different material in phantom.

  8. Impact on internal doses of photon SAFs derived with the GSF adult male voxel phantom.

    Science.gov (United States)

    Smith, T J; Phipps, A W; Petoussi-Henss, N; Zankl, M

    2001-05-01

    This paper describes the effect on over 3,000 sets of internal dose estimates of using photon Specific Absorbed Fractions (SAFs) calculated using two different types of phantoms, specifically the MIRD-type anthropomorphic phantom originally developed by Snyder and the new adult male voxel phantom, GOLEM, developed at GSF. The SAFs based on the MIRD-type phantom are currently used by the International Commission on Radiological Protection (ICRP) in internal dose calculations, but there are suggestions of moving towards SAFs generated from voxel phantoms, thus there is an interest in the potential differences in internal doses. Overall, it is found that some tissue doses calculated using the voxel phantoms can differ significantly from those of the MIRD-type phantom; however, the effective dose appears to be quite robust to changes in photon SAFs.

  9. Development of skeleton model for use in polygonal-mesh-type ICRP reference phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Thang Tat; Yeom, Yeon Soo; Han, Min Cheol; Wang, Zhao Jun; Kim, Han Sung; Kim, Chan Hyeong [Dept.of Nuclear Engineering, Hanyang University, Seoul (Korea, Republic of)

    2015-04-15

    In order to overcome the limitations, we are currently developing the polygonal-mesh versions of the ICRP reference phantoms by converting the ICRP reference voxel phantoms to polygonal-mesh format. As a part of the ICRP reference phantom conversion project, the present study completed the conversion of skeleton, which is a very complex framework of the body, while addressing some critical problems of the skeleton of the ICRP reference voxel phantoms. The converted skeleton models were also evaluated by comparing dose values of RBM and endosteum with those of the ICRP reference voxel phantoms. As a part of the ICRP reference phantom conversion project, the present study successfully completed skeleton conversion of the ICRP reference adult male and female phantoms to polygonal-mesh format. A comprehensive study of dosimetric effects by the skeleton conversion will be performed in the future.

  10. Glycerol as high-permittivity liquid filler in dielectric silicone elastomers

    DEFF Research Database (Denmark)

    Mazurek, Piotr Stanislaw; Yu, Liyun; Gerhard, R.

    2016-01-01

    A recently reported novel class of elastomers was tested with respect to its dielectric properties. The new elastomer materialis based on a commercially available poly(dimethylsiloxane) composition, which has been modified by embedding glycerol droplets intoits matrix. The approach has two major ...

  11. Glycerol as high-permittivity liquid filler in dielectric silicone elastomers

    DEFF Research Database (Denmark)

    Mazurek, Piotr Stanislaw; Yu, Liyun; Skov, Anne Ladegaard

    A recently reported novel class of elastomers was tested with respect to its dielectric properties. The new elastomer material is based on a commercially available polydimethylsiloxane (PDMS) composition, which has been modified by embedding glycerol droplets into its matrix.The approach has two ...

  12. High-Permittivity Conjugated Polyelectrolyte Interlayers for High-Performance Bulk Heterojunction Organic Solar Cells.

    Science.gov (United States)

    Kesters, Jurgen; Govaerts, Sanne; Pirotte, Geert; Drijkoningen, Jeroen; Chevrier, Michèle; Van den Brande, Niko; Liu, Xianjie; Fahlman, Mats; Van Mele, Bruno; Lutsen, Laurence; Vanderzande, Dirk; Manca, Jean; Clément, Sébastien; Von Hauff, Elizabeth; Maes, Wouter

    2016-03-01

    Conjugated polyelectrolyte (CPE) interfacial layers present a powerful way to boost the I-V characteristics of organic photovoltaics. Nevertheless, clear guidelines with respect to the structure of high-performance interlayers are still lacking. In this work, impedance spectroscopy is applied to probe the dielectric permittivity of a series of polythiophene-based CPEs. The presence of ionic pendant groups grants the formation of a capacitive double layer, boosting the charge extraction and device efficiency. A counteracting effect is the diminishing affinity with the underlying photoactive layer. To balance these two effects, we found copolymer structures containing nonionic side chains to be beneficial.

  13. High permittivity polyaniline-barium titanate nanocomposites with excellent electromagnetic interference shielding response

    Science.gov (United States)

    Saini, Parveen; Arora, Manju; Gupta, Govind; Gupta, Bipin Kumar; Singh, Vidya Nand; Choudhary, Veena

    2013-05-01

    Organic conductive polymers are at the forefront of materials science research because of their diverse applications built around their interesting and unique properties. This work reports for the first time a correlation between the structural, electrical, and electromagnetic properties of polyaniline (PANI)-tetragonal BaTiO3 (TBT) nanocomposites prepared by in-situ emulsion polymerization. XRD studies and HRTEM micrographs of these nanocomposites clearly revealed the incorporation of TBT nanoparticles in the conducting PANI matrix. EPR and XPS measurements reveal that increase in loading level of BaTiO3 results in a reduction of the doping level of PANI. The Ku-Band (12.4-18 GHz) network analysis of these composites shows exceptional microwave shielding response with absorption dominated total shielding effectiveness (SET) value of -71.5 dB (blockage of more than 99.99999% of incident radiation) which is the highest value reported in the literature. Such a high attenuation level, which critically depends on the fraction of BaTiO3 is attributed to optimized dielectric and electrical attributes. This demonstrates the possibility of using these materials in stealth technology and for making futuristic radar absorbing materials (RAMs).Organic conductive polymers are at the forefront of materials science research because of their diverse applications built around their interesting and unique properties. This work reports for the first time a correlation between the structural, electrical, and electromagnetic properties of polyaniline (PANI)-tetragonal BaTiO3 (TBT) nanocomposites prepared by in-situ emulsion polymerization. XRD studies and HRTEM micrographs of these nanocomposites clearly revealed the incorporation of TBT nanoparticles in the conducting PANI matrix. EPR and XPS measurements reveal that increase in loading level of BaTiO3 results in a reduction of the doping level of PANI. The Ku-Band (12.4-18 GHz) network analysis of these composites shows exceptional microwave shielding response with absorption dominated total shielding effectiveness (SET) value of -71.5 dB (blockage of more than 99.99999% of incident radiation) which is the highest value reported in the literature. Such a high attenuation level, which critically depends on the fraction of BaTiO3 is attributed to optimized dielectric and electrical attributes. This demonstrates the possibility of using these materials in stealth technology and for making futuristic radar absorbing materials (RAMs). Electronic supplementary information (ESI) available. See DOI: 10.1039/c3nr00634d

  14. A simple method for reducing inevitable dielectric loss in high-permittivity dielectric elastomers

    DEFF Research Database (Denmark)

    Madsen, Frederikke Bahrt; Yu, Liyun; Mazurek, Piotr Stanislaw

    2016-01-01

    elastomer matrix, with high dielectric permittivity and a low Young's modulus, aligned with no loss of mechanical stability, was prepared through the use of commercially available chloropropyl-functional silicone oil mixed into a tough commercial liquid silicone rubber silicone elastomer. The addition......Commercial viability of dielectric elastomers (DEs) is currently limited by a few obstacles, including high driving voltages (in the kV range). Driving voltage can be lowered by either decreasing the Young's modulus or increasing the dielectric permittivity of silicone elastomers, or a combination...... of chloropropyl-functional silicone oil in concentrations up to 30 phr was found to improve the properties of the silicone elastomer significantly, as dielectric permittivity increased to 4.4, dielectric breakdown increased up to 25% and dielectric losses were reduced. The chloropropyl-functional silicone oil...

  15. Research on the Crystal Growth and Dielectric Properties of High Permittivity Ferroelectric Materials.

    Science.gov (United States)

    1984-05-01

    TY CLASSIPICAtgO#. OP THIS PAGN 9 Rockwell International Scince Center SC5345,4AR TABLE OF CONTENTS Page 1.0 INTRODUCTION AND PROGRESS SUMMARY...firmed in our own work, in which dielectric anisotropies greater than 1.5:1 have been observed for directions perpendicular and parallel to the...the orthorhombic b-axis, these results support the conclusion that the c-axis is oriented perpendicular to the uniaxial hot-pressing direction . This

  16. Phantom limb pain: cortical plasticity and novel therapeutic approaches.

    Science.gov (United States)

    Flor, H; Birbaumer, N

    2000-10-01

    Phantom limb pain is still a very frequent consequence of peripheral deafferentation or amputation of a limb. Recent findings from animal and neuroimaging studies suggest that phantom limb pain might be a central phenomenon, related to changes in the cortical, thalamic and spinal representation of the painful limb, and might be a type of somatosensory pain memory. Based on these assumptions, new treatment approaches focus on sensory discrimination training or motor cortex stimulation in an effort to influence cortical reorganization. Prevention of perpetuation of a somatosensory pain memory might also be possible through pharmacological agents such as N-methyl-D-aspartate antagonists and gamma-aminobutyric acid agonists, substances that have been shown to influence and prevent cortical reorganization.

  17. The motor cortex and its role in phantom limb phenomena.

    Science.gov (United States)

    Reilly, Karen T; Sirigu, Angela

    2008-04-01

    Limb amputation results in plasticity of connections between the brain and muscles; the cortical motor representation of the missing limb seemingly disappears. The disappearance of the hand's motor representation is, however, difficult to reconcile with evidence that a perceptual representation of the missing limb persists in the form of a phantom limb endowed with sensory and motor qualities. Here, we argue that despite considerable reorganization within the motor cortex of upper-limb amputees, the representation of the amputated hand does not disappear. We hypothesize that two levels of hand-movement representation coexist within the primary motor cortex; at one level, limb movements are specified in terms of arm and hand motor commands, and at another level, limb movements are specified as muscles synergies. We propose that primary motor cortex reorganization after amputation concerns primarily the upper limb's muscular map but not its motor command map and that the integrity of the motor command map underlies the existence of the phantom limb.

  18. Bulk viscosity, interaction and the viability of phantom solutions

    CERN Document Server

    Leyva, Yoelsy

    2016-01-01

    We study the dynamics of a bulk viscosity model in the Eckart approach for a spatially flat Friedmann-Robertson-Walker (FRW) universe. We have included radiation and dark energy, assumed as perfect fluids, and dark matter treated as an imperfect fluid having bulk viscosity. We also introduce an interaction term between the dark matter and dark energy components. Considering that the bulk viscosity is proportional to the dark matter energy density and imposing a complete cosmological dynamics, we find bounds on the bulk viscosity in order to reproduce a matter-dominated era (MDE). This constraint is independent of the interaction term. Some late time phantom solutions are mathematically possible. However, the constraint imposed by a MDE restricts the interaction parameter, in the phantom solutions, to a region consistent with a null value, eliminating the possibility of late time stable solutions with $w<-1$. From the different cases that we study, the only possible scenario, with bulk viscosity and interac...

  19. Noncontact ultrasound imaging applied to cortical bone phantoms.

    Science.gov (United States)

    Bulman, J B; Ganezer, K S; Halcrow, P W; Neeson, Ian

    2012-06-01

    The purpose of this paper was to take the first steps toward applying noncontact ultrasound (NCU) to the tasks of monitoring osteoporosis and quantitative ultrasound imaging (QUS) of cortical bone. The authors also focused on the advantages of NCU, such as its lack of reliance on a technologist to apply transducers and a layer of acoustical coupling gel, the ability of the transducers to operate autonomously as specified by preprogrammed software, and the likely reduction in statistical and systematic errors associated with the variability in the pressure applied by the clinician to the transmitting transducer that NCU might provide. The authors also undertook this study in order to find additional applications of NCU beyond its past limited usage in assessing the severity of third degree burns. A noncontact ultrasound imaging system using a pair of specially designed broadband, 1.5 MHz noncontact piezoelectric transducers and cortical bone phantoms, were used to determine bone mineral density (BMD), speed of sound (SOS), integrated response (IR), and ultrasonic transmittance. Air gaps of greater than 3 cm, two transmission and two reflection paths, and a digital signal processor were also used in the collection of data from phantoms of nominal mass densities that varied from 1.17 to 2.25 g/cm(3) and in bone mineral density from 0 to 1.7 g/cm(3). Good correlations between known BMD and measured SOS, IR, and transmittance were obtained for all 17 phantoms, and methods for quantifying and minimizing sources of systematic errors were outlined. The BMD of the phantom sets extended through most of the in vivo range found in cortical bone. A total of 16-20 repeated measurements of the SOS, thickness, and IR for the phantom set that were conducted over a period of several months showed a small variation in the range of measurements of ±1%-2%. These NCU data were shown to be in agreement with similar results using contact ultrasound to be within 1%-2%. Transmittance

  20. Development of Phantom Limb Pain after Femoral Nerve Block

    Directory of Open Access Journals (Sweden)

    Sadiah Siddiqui

    2014-01-01

    Full Text Available Historically, phantom limb pain (PLP develops in 50–80% of amputees and may arise within days following an amputation for reasons presently not well understood. Our case involves a 29-year-old male with previous surgical amputation who develops PLP after the performance of a femoral nerve block. Although there have been documented cases of reactivation of PLP in amputees after neuraxial technique, there have been no reported events associated with femoral nerve blockade. We base our discussion on the theory that symptoms of phantom limb pain are of neuropathic origin and attempt to elaborate the link between regional anesthesia and PLP. Further investigation and understanding of PLP itself will hopefully uncover a relationship between peripheral nerve blocks targeting an affected limb and the subsequent development of this phenomenon, allowing physicians to take appropriate steps in prevention and treatment.

  1. Observation with Calcifications of Breast Tissue Phantoms Using Acoustic Resonance

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jeong Goo [Dept. of Radiological Science, Hanseo University, Seoul (Korea, Republic of); Ha, Myeung Jin [Haesung OB and GY Clinic, Seosan (Korea, Republic of)

    2008-03-15

    Diagnosis of breast ultrasound is better than mammography in the early detection of breast cancer, but, it is difficult to detect microcalcification. We studied on detection for calcification of breast tissue using acoustic resonance and power doppler with 7.5 MHz linear probe in breast ultrasound. We first constructed breast tissue phantom made of gelatin and saw breast, and then observed calcification by the change of external vibration. Calcification injected breast tissue phantom visualized the difference for brightness and region of color in ROI regions of power doppler. Acoustic resonance almost never visualized in low frequency regions, plateau constituted in about 300-400 Hz and colors vanished according to the increase of frequency.

  2. Computerized evaluation of mammographic image quality using phantom images.

    Science.gov (United States)

    Dougherty, G

    1998-01-01

    A simple, quick and computerized method for quantitatively evaluating the image quality of mammography phantom images has been developed. Images of the American College of Radiology (ACR) mammographic accreditation phantoms were acquired under different X-ray techniques, scored and ranked subjectively by five expert readers, and digitized for quantitative analysis. The contrast and signal-to-noise (contrast-to-noise) ratios of the main nodule and microcalcification group were obtained accurately and reproducibly using an image processing protocol. The contrast values were successful at discriminating differences in image quality due to variations in scatter conditions (as a result of different kVp's, and the presence or absence of an acrylic scatterer and/or a moving Bucky grid). They were more precise, reproducible and sensitive than the ACR score. In particular, the contrast of the main nodule was highly correlated (r(s) = 0.988: pimage quality by our panel of expert readers.

  3. Phantom Limbs, Neuroprosthetics, and the Developmental Origins of Embodiment.

    Science.gov (United States)

    Blumberg, Mark S; Dooley, James C

    2017-10-01

    Amputees who wish to rid themselves of a phantom limb must weaken the neural representation of the absent limb. Conversely, amputees who wish to replace a lost limb must assimilate a neuroprosthetic with the existing neural representation. Whether we wish to remove a phantom limb or assimilate a synthetic one, we will benefit from knowing more about the developmental process that enables embodiment. A potentially critical contributor to that process is the spontaneous activity - in the form of limb twitches - that occurs exclusively and abundantly during active (REM) sleep, a particularly prominent state in early development. The sensorimotor circuits activated by twitching limbs, and the developmental context in which activation occurs, could provide a roadmap for creating neuroprosthetics that feel as if they are part of the body. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Stable phantom materials for ultrasound and optical imaging

    Science.gov (United States)

    Cabrelli, Luciana C.; Pelissari, Pedro I. B. G. B.; Deana, Alessandro M.; Carneiro, Antonio A. O.; Pavan, Theo Z.

    2017-01-01

    Phantoms mimicking the specific properties of biological tissues are essential to fully characterize medical devices. Water-based materials are commonly used to manufacture phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages, such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue-mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. A styrene-ethylene/butylene-styrene (SEBS) copolymer in mineral oil samples was made varying the SEBS concentration between 5%-15%, and low-density polyethylene (LDPE) between 0%-9%. Acoustic properties, such as the speed of sound and the attenuation coefficient, were obtained using frequencies ranging from 1-10 MHz, and were consistent with that of soft tissues. These properties were controlled varying SEBS and LDPE concentration. To characterize the optical properties of the samples, the diffuse reflectance and transmittance were measured. Scattering and absorption coefficients ranging from 400 nm-1200 nm were calculated for each compound. SEBS gels are a translucent material presenting low optical absorption and scattering coefficients in the visible region of the spectrum, but the presence of LDPE increased the turbidity. Adding LDPE increased the absorption and scattering of the phantom materials. Ultrasound and photoacoustic images of a heterogeneous phantom made of LDPE/SEBS containing a spherical inclusion were obtained. Annatto dye was added to the inclusion to enhance the optical absorbance. The results suggest that copolymer gels are promising for ultrasound and optical imaging, making them also potentially useful for photoacoustic imaging.

  5. Induced sensorimotor brain plasticity controls pain in phantom limb patients

    OpenAIRE

    Yanagisawa, Takufumi; Fukuma, Ryohei; Seymour, Ben; Hosomi, Koichi; Kishima, Haruhiko; Shimizu, Takeshi; Yokoi, Hiroshi; Hirata, Masayuki; Yoshimine, Toshiki; Kamitani, Yukiyasu; Saitoh, Youichi

    2016-01-01

    The cause of pain in a phantom limb after partial or complete deafferentation is an important problem. A popular but increasingly controversial theory is that it results from maladaptive reorganization of the sensorimotor cortex, suggesting that experimental induction of further reorganization should affect the pain, especially if it results in functional restoration. Here we use a brain-machine interface (BMI) based on real-time magnetoencephalography signals to reconstruct affected hand mov...

  6. Image guided constitutive modeling of the silicone brain phantom

    Science.gov (United States)

    Puzrin, Alexander; Skrinjar, Oskar; Ozan, Cem; Kim, Sihyun; Mukundan, Srinivasan

    2005-04-01

    The goal of this work is to develop reliable constitutive models of the mechanical behavior of the in-vivo human brain tissue for applications in neurosurgery. We propose to define the mechanical properties of the brain tissue in-vivo, by taking the global MR or CT images of a brain response to ventriculostomy - the relief of the elevated intracranial pressure. 3D image analysis translates these images into displacement fields, which by using inverse analysis allow for the constitutive models of the brain tissue to be developed. We term this approach Image Guided Constitutive Modeling (IGCM). The presented paper demonstrates performance of the IGCM in the controlled environment: on the silicone brain phantoms closely simulating the in-vivo brain geometry, mechanical properties and boundary conditions. The phantom of the left hemisphere of human brain was cast using silicon gel. An inflatable rubber membrane was placed inside the phantom to model the lateral ventricle. The experiments were carried out in a specially designed setup in a CT scanner with submillimeter isotropic voxels. The non-communicative hydrocephalus and ventriculostomy were simulated by consequently inflating and deflating the internal rubber membrane. The obtained images were analyzed to derive displacement fields, meshed, and incorporated into ABAQUS. The subsequent Inverse Finite Element Analysis (based on Levenberg-Marquardt algorithm) allowed for optimization of the parameters of the Mooney-Rivlin non-linear elastic model for the phantom material. The calculated mechanical properties were consistent with those obtained from the element tests, providing justification for the future application of the IGCM to in-vivo brain tissue.

  7. Phantom Friedmann Cosmologies and Higher-Order Characteristics of Expansion

    OpenAIRE

    Dabrowski, Mariusz P.; Stachowiak, Tomasz

    2004-01-01

    We discuss a more general class of phantom ($p -1$) matter. We show that many types of evolution which include both Big-Bang and Big-Rip singularities are admitted and give explicit examples. Among some interesting models, there exist non-singular oscillating (or "bounce") cosmologies, which appear due to a competition between positive and negative pressure of variety of matter content. From the point o...

  8. Stable phantom materials for ultrasound and optical imaging.

    Science.gov (United States)

    Cabrelli, Luciana C; Pelissari, Pedro I B G B; Deana, Alessandro M; Carneiro, Antonio A O; Pavan, Theo Z

    2017-01-21

    Phantoms mimicking the specific properties of biological tissues are essential to fully characterize medical devices. Water-based materials are commonly used to manufacture phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages, such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue-mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. A styrene-ethylene/butylene-styrene (SEBS) copolymer in mineral oil samples was made varying the SEBS concentration between 5%-15%, and low-density polyethylene (LDPE) between 0%-9%. Acoustic properties, such as the speed of sound and the attenuation coefficient, were obtained using frequencies ranging from 1-10 MHz, and were consistent with that of soft tissues. These properties were controlled varying SEBS and LDPE concentration. To characterize the optical properties of the samples, the diffuse reflectance and transmittance were measured. Scattering and absorption coefficients ranging from 400 nm-1200 nm were calculated for each compound. SEBS gels are a translucent material presenting low optical absorption and scattering coefficients in the visible region of the spectrum, but the presence of LDPE increased the turbidity. Adding LDPE increased the absorption and scattering of the phantom materials. Ultrasound and photoacoustic images of a heterogeneous phantom made of LDPE/SEBS containing a spherical inclusion were obtained. Annatto dye was added to the inclusion to enhance the optical absorbance. The results suggest that copolymer gels are promising for ultrasound and optical imaging, making them also potentially useful for photoacoustic imaging.

  9. On the accretion of phantom energy onto wormholes

    Energy Technology Data Exchange (ETDEWEB)

    Gonzalez-Diaz, Pedro F. [Colina de los Chopos, Centro de Fisica ' Miguel A. Catalan' , Instituto de Matematicas y Fisica Fundamental, Consejo Superior de Investigaciones Cientificas, Serrano 121, 28006 Madrid (Spain)]. E-mail: p.gonzalezdiaz@imaff.cfmac.csic.es

    2006-01-12

    By using a properly generalized accretion formalism it is argued that the accretion of phantom energy onto a wormhole does not make the size of the wormhole throat to comovingly scale with the scale factor of the universe, but instead induces an increase of that size so big that the wormhole can engulf the universe itself before it reaches the big rip singularity, at least relative to an asymptotic observer.

  10. Automatic generation of digital anthropomorphic phantoms from simulated MRI acquisitions

    Science.gov (United States)

    Lindsay, C.; Gennert, M. A.; KÓ§nik, A.; Dasari, P. K.; King, M. A.

    2013-03-01

    In SPECT imaging, motion from patient respiration and body motion can introduce image artifacts that may reduce the diagnostic quality of the images. Simulation studies using numerical phantoms with precisely known motion can help to develop and evaluate motion correction algorithms. Previous methods for evaluating motion correction algorithms used either manual or semi-automated segmentation of MRI studies to produce patient models in the form of XCAT Phantoms, from which one calculates the transformation and deformation between MRI study and patient model. Both manual and semi-automated methods of XCAT Phantom generation require expertise in human anatomy, with the semiautomated method requiring up to 30 minutes and the manual method requiring up to eight hours. Although faster than manual segmentation, the semi-automated method still requires a significant amount of time, is not replicable, and is subject to errors due to the difficulty of aligning and deforming anatomical shapes in 3D. We propose a new method for matching patient models to MRI that extends the previous semi-automated method by eliminating the manual non-rigid transformation. Our method requires no user supervision and therefore does not require expert knowledge of human anatomy to align the NURBs to anatomical structures in the MR image. Our contribution is employing the SIMRI MRI simulator to convert the XCAT NURBs to a voxel-based representation that is amenable to automatic non-rigid registration. Then registration is used to transform and deform the NURBs to match the anatomy in the MR image. We show that our automated method generates XCAT Phantoms more robustly and significantly faster than the previous semi-automated method.

  11. Dynamic heart phantom with functional mitral and aortic valves

    Science.gov (United States)

    Vannelli, Claire; Moore, John; McLeod, Jonathan; Ceh, Dennis; Peters, Terry

    2015-03-01

    Cardiac valvular stenosis, prolapse and regurgitation are increasingly common conditions, particularly in an elderly population with limited potential for on-pump cardiac surgery. NeoChord©, MitraClipand numerous stent-based transcatheter aortic valve implantation (TAVI) devices provide an alternative to intrusive cardiac operations; performed while the heart is beating, these procedures require surgeons and cardiologists to learn new image-guidance based techniques. Developing these visual aids and protocols is a challenging task that benefits from sophisticated simulators. Existing models lack features needed to simulate off-pump valvular procedures: functional, dynamic valves, apical and vascular access, and user flexibility for different activation patterns such as variable heart rates and rapid pacing. We present a left ventricle phantom with these characteristics. The phantom can be used to simulate valvular repair and replacement procedures with magnetic tracking, augmented reality, fluoroscopy and ultrasound guidance. This tool serves as a platform to develop image-guidance and image processing techniques required for a range of minimally invasive cardiac interventions. The phantom mimics in vivo mitral and aortic valve motion, permitting realistic ultrasound images of these components to be acquired. It also has a physiological realistic left ventricular ejection fraction of 50%. Given its realistic imaging properties and non-biodegradable composition—silicone for tissue, water for blood—the system promises to reduce the number of animal trials required to develop image guidance applications for valvular repair and replacement. The phantom has been used in validation studies for both TAVI image-guidance techniques1, and image-based mitral valve tracking algorithms2.

  12. The UF family of reference hybrid phantoms for computational radiation dosimetry

    Science.gov (United States)

    Lee, Choonsik; Lodwick, Daniel; Hurtado, Jorge; Pafundi, Deanna; Williams, Jonathan L.; Bolch, Wesley E.

    2010-01-01

    Computational human phantoms are computer models used to obtain dose distributions within the human body exposed to internal or external radiation sources. In addition, they are increasingly used to develop detector efficiencies for in vivo whole-body counters. Two classes of computational human phantoms have been widely utilized for dosimetry calculation: stylized and voxel phantoms that describe human anatomy through mathematical surface equations and 3D voxel matrices, respectively. Stylized phantoms are flexible in that changes to organ position and shape are possible given avoidance of region overlap, while voxel phantoms are typically fixed to a given patient anatomy, yet can be proportionally scaled to match individuals of larger or smaller stature, but of equivalent organ anatomy. Voxel phantoms provide much better anatomical realism as compared to stylized phantoms which are intrinsically limited by mathematical surface equations. To address the drawbacks of these phantoms, hybrid phantoms based on non-uniform rational B-spline (NURBS) surfaces have been introduced wherein anthropomorphic flexibility and anatomic realism are both preserved. Researchers at the University of Florida have introduced a series of hybrid phantoms representing the ICRP Publication 89 reference newborn, 15 year, and adult male and female. In this study, six additional phantoms are added to the UF family of hybrid phantoms—those of the reference 1 year, 5 year and 10 year child. Head and torso CT images of patients whose ages were close to the targeted ages were obtained under approved protocols. Major organs and tissues were segmented from these images using an image processing software, 3D-DOCTOR™. NURBS and polygon mesh surfaces were then used to model individual organs and tissues after importing the segmented organ models to the 3D NURBS modeling software, Rhinoceros™. The phantoms were matched to four reference datasets: (1) standard anthropometric data, (2) reference

  13. Fan edits and the legacy of The Phantom Edit

    Directory of Open Access Journals (Sweden)

    Joshua Wille

    2014-09-01

    Full Text Available A fan edit can generally be defined as an alternative version of a film or television text created by a fan. It offers a different viewing experience, much as a song remix offers a different listening experience. The contemporary wave of fan edits has emerged during the remix zeitgeist of digital media and at a time when digital video editing technology has become more affordable and popular. The increasing number of alternative versions of films and the works of revisionist Hollywood filmmakers such as George Lucas have contributed to a greater public understanding of cinema as a fluid medium instead of one that exists in a fixed form. The Phantom Edit (2000, a seminal fan edit based on Lucas's Star Wars Episode I: The Phantom Menace (1999, inspired new ranks of fan editors. However, critics have misunderstood fan edits as merely the work of disgruntled fans. In order to provide a critical and historical basis for studies in fan editing as a creative practice, I examine previous interpretations of fan edits in the context of relevant contemporary works, and I use an annotated chronology of The Phantom Edit to trace its influence on subsequent fan editing communities and uncover their relationship with intellectual property disputes.

  14. Possible association between phantom vibration syndrome and occupational burnout.

    Science.gov (United States)

    Chen, Chao-Pen; Wu, Chi-Cheng; Chang, Li-Ren; Lin, Yu-Hsuan

    2014-01-01

    Phantom vibration syndrome (PVS) and phantom ringing syndrome (PRS) occur in many cell phone users. Previous studies have indicated an association between PVS/PRS and job stress. The aim of this study was to determine if PVS/PRS were also associated with occupational burnout. This was a cross-sectional study of 384 employees of a high-tech company in northern Taiwan. They all completed a phantom vibration and ringing questionnaire, the Hospital Anxiety and Depression Scale, and the Chinese version of the Occupational Burnout Inventory. Significantly more women and people with at least a college education were in the population with PRS and PVS, respectively. Anxiety and depression had no associations with PVS/PRS. Higher scores for personal fatigue, job fatigue, and service target fatigue had an independent impact on the presence of PVS, but only a higher score for service target fatigue had an independent impact on the presence of PRS. The independent association between work-related burnout and PVS/PRS suggests that PVS/PRS may be a harbinger of mental stress or a component of the clinical burnout syndrome, and may even be a more convenient and accurate predictor of occupational burnout.

  15. Somatic and movement inductions phantom limb in non-amputees

    Science.gov (United States)

    Casas, D. M.; Gentiletti, G. G.; Braidot, A. A.

    2016-04-01

    The illusion of the mirror box is a tool for phantom limb pain treatment; this article proposes the induction of phantom limb syndrome on non-amputees upper limb, with a neurological trick of the mirror box. With two study situations: a) Somatic Induction is a test of the literature reports qualitatively, and novel proposal b) Motor Induction, which is an objective report by recording surface EEG. There are 3 cases proposed for Motor illusion, for which grasped movement is used: 1) Control: movement is made, 2) illusion: the mirror box is used, and 3) Imagination: no movement is executed; the subject only imagines its execution. Three different tasks are registered for each one of them (left hand, right hand, and both of them). In 64% of the subjects for somatic experience, a clear response to the illusion was observed. In the experience of motor illusion, cortical activation is detected in both hemispheres of the primary motor cortex during the illusion, where the hidden hand remains motionless. These preliminary findings in phantom limb on non-amputees can be a tool for neuro-rehabilitation and neuro-prosthesis control training.

  16. Phantom Friedmann cosmologies and higher-order characteristics of expansion

    Science.gov (United States)

    Dabrowski, Mariusz P.; Stachowiak, Tomasz

    2006-04-01

    We discuss a more general class of phantom (p -1) matter. We show that many types of evolution which include both Big-Bang and Big-Rip singularities are admitted and give explicit examples. Among some interesting models, there exist non-singular oscillating (or “bounce”) cosmologies, which appear due to a competition between positive and negative pressure of variety of matter content. From the point of view of the current observations the most interesting cosmologies are the ones which start with a Big-Bang and terminate at a Big-Rip. A related consequence of having a possibility of two types of singularities is that there exists an unstable static universe approached by the two asymptotic models—one of them reaches Big-Bang, and another reaches Big-Rip. We also give explicit relations between density parameters Ω and the dynamical characteristics for these generalized phantom models, including higher-order observational characteristics such as jerk and “kerk.” Finally, we discuss the observational quantities such as luminosity distance, angular diameter, and source counts, both in series expansion and explicitly, for phantom models. Our series expansion formulas for the luminosity distance and the apparent magnitude go as far as to the fourth-order in redshift z term, which includes explicitly not only the jerk, but also the “kerk” (or “snap”) which may serve as an indicator of the curvature of the universe.

  17. Computed tomography scan optimization using head phantom and radiochromic films

    Energy Technology Data Exchange (ETDEWEB)

    Fernandes, Lorena C.; Santana, P.C.; Velasquez, Carlos E.; Mourao, Arnaldo P., E-mail: lorena.cfernandes@hotmail.com, E-mail: carlosvelcab@hotmail.com, E-mail: pridili@gmail.com, E-mail: apmourao@gmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte (Brazil). Departamento de Engenharia Nuclear; Centro de Imagem Molecular do INCT-Medicina Molecular (CIMol/UFMG) Belo Horizonte (Brazil); Centro Federal de Educação Tecnológica de Minas Gerais (CEFET-MG), Belo Horizonte (Brazil)

    2017-11-01

    The research and development in technology applied to computed tomography has been improve in the image quality, resulting in the best identification of diseases, and therefore an increase in the number of exams, among them the head exams can be highlighted. In order to promote a radioprotection and reduction on the dose of the general public some international agencies have stipulated dose limits to be followed and the implementation of the principles of ALARA in all establishments that use ionizing radiation. One of these principles is the optimization that should be treated with substantial attention, because the reduction of radiation doses can be feasible as long as it does not compromise the tomographic images; such practice is difficult to perform due to the lack of proper guidance. In optimization of the CT exams, not only the lowest dose is evaluated to obtain diagnostic image, but also should be knowledge the dose distribution throughout the scanned area. In this work were used a cylindrical head phantom of PMMA, a GE Discovery CT scan with 64 channels, and radiochromic films. The films were positioned in the phantom in their central region for the dose evaluation using the automatic control for the voltages of 80, 100 and 120 kV. The images were acquired from the scan of the phantom and the film readings were obtained through digital images. The results show an evaluation of the longitudinal kerma profiles, dose delivered, and the image noise was also observed using the central slice images. (author)

  18. The Edinburgh Pipe Phantom: characterising ultrasound scanners beyond 50 MHz

    Energy Technology Data Exchange (ETDEWEB)

    Moran, C M [Medical Physics, University of Edinburgh, Edinburgh, EH16 4TJ (United Kingdom); Ellis, W; Janeczko, A; Pye, S D [Medical Physics Department, NHS Lothian University Hospitals Division, Royal Infirmary, Edinburgh EH16 4SA (United Kingdom); Bell, D, E-mail: carmel.moran@ed.ac.uk [Precision Acoustics Ltd, Hampton Farm Business Park, Dorset, DT2 8QH (United Kingdom)

    2011-02-01

    The ability to measure the imaging performance of pre-clinical and clinical ultrasound scanners is important but difficult to achieve objectively. The Edinburgh Pipe Phantom was originally developed to assess the technical performance of clinical scanners up to 15MHz. It comprises a series of anechoic cylinders with diameters 0.4 - 8mm embedded in agar-based tissue mimic. This design enables measurement of the characteristics (Resolution Integral R, Depth of Field L{sub R}, Characteristic Resolution D{sub R}) of grey-scale images with transducer centre frequencies from about 2.5 to 15MHz. We describe further development of the Edinburgh Pipe Phantom as a tool for characterising ultrasound scanners with centre frequencies up to at least 50MHz. This was achieved by moulding a series of anechoic pipe structures (diameters 0.045 - 1.5mm) into a block of agar-based tissue mimic. We report measurements of R, L{sub R} and D{sub R} for a series of 10 transducers (5 single element and 5 array transducers) designed for pre-clinical scanning, with centre frequencies in the range 15-55 MHz. Values of R ranged from 18-72 for single element transducers and 49-58 for linear array transducers. In conclusion, the pre-clinical pipe phantom was able to successfully determine the imaging characteristics of ultrasound probes up to 55MHz.

  19. An analysis of the self-control and criminal versatility of gang and dating violence offenders.

    Science.gov (United States)

    Chapple, Constance L; Hope, Trina L

    2003-12-01

    How versatile are gang and dating violence offenders? Current gang research highlights the versatility of gang members, yet the versatility of intimate violence offenders is often unexamined. Gottfredson and Hirschi, A General Theory of Crime (1990), support the idea of versatile rather than specialized offenders and suggests that low self-control is associated with a host of criminal and noncriminal risk-taking activities. Using data from a self-report sample of 1139 youths in grades 9 through 11, we investigated both the versatility of gang and dating violence offenders and theoretical variables associated with each. We find disproportionate offending by dating and gang violence offenders in a variety of crimes, as well as considerable overlap in the independent variables associated with both types of violence. Low levels of self-control and exposure to general and crime-specific criminal opportunities are significantly associated with engaging in dating and gang violence.

  20. A realistic 3-D gated cardiac phantom for quality control of gated myocardial perfusion SPET: the Amsterdam gated (AGATE) cardiac phantom

    NARCIS (Netherlands)

    Visser, Jacco J. N.; Sokole, Ellinor Busemann; Verberne, Hein J.; Habraken, Jan B. A.; van de Stadt, Huybert J. F.; Jaspers, Joris E. N.; Shehata, Morgan; Heeman, Paul M.; van Eck-Smit, Berthe L. F.

    2004-01-01

    A realistic 3-D gated cardiac phantom with known left ventricular (LV) volumes and ejection fractions (EFs) was produced to evaluate quantitative measurements obtained from gated myocardial single-photon emission tomography (SPET). The 3-D gated cardiac phantom was designed and constructed to fit

  1. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-01

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus Hp(3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  2. Design of a head phantom produced on a 3D rapid prototyping printer and comparison with a RANDO and 3M lucite head phantom in eye dosimetry applications.

    Science.gov (United States)

    Homolka, Peter; Figl, Michael; Wartak, Andreas; Glanzer, Mathias; Dünkelmeyer, Martina; Hojreh, Azadeh; Hummel, Johann

    2017-04-21

    An anthropomorphic head phantom including eye inserts allowing placement of TLDs 3 mm below the cornea has been produced on a 3D printer using a photo-cured acrylic resin to best allow tissue equivalence. Thus H p (3) can be determined in radiological and interventional photon radiation fields. Eye doses and doses to the forehead have been compared to an Alderson RANDO head and a 3M Lucite skull phantom in terms of surface dose per incident air kerma for frontal irradiation since the commercial phantoms do not allow placement of TLDs 3 mm below the corneal surface. A comparison of dose reduction factors (DRFs) of a common lead glasses model has also been performed. Eye dose per incident air kerma were comparable between all three phantoms (printed phantom: 1.40, standard error (SE) 0.04; RANDO: 1.36, SE 0.03; 3M: 1.37, SE 0.03). Doses to the forehead were identical to eye surface doses for the printed phantom and the RANDO head (ratio 1.00 SE 0.04, and 0.99 SE 0.03, respectively). In the 3M Lucite skull phantom dose on the forehead was 15% lower than dose to the eyes attributable to phantom properties. DRF of a sport frame style leaded glasses model with 0.75 mm lead equivalence measured were 6.8 SE 0.5, 9.3 SE 0.4 and 10.5 SE 0.5 for the RANDO head, the printed phantom, and the 3M Lucite head phantom, respectively, for frontal irradiation. A comparison of doses measured in 3 mm depth and on the surface of the eyes in the printed phantom revealed no difference larger than standard errors from TLD dosimetry. 3D printing offers an interesting opportunity for phantom design with increasing potential as printers allowing combinations of tissue substitutes will become available. Variations between phantoms may provide a useful indication of uncertainty budgets when using phantom measurements to estimate individual personnel doses.

  3. An externally and internally deformable, programmable lung motion phantom

    Energy Technology Data Exchange (ETDEWEB)

    Cheung, Yam; Sawant, Amit, E-mail: amit.sawant@utsouthwestern.edu [UT Southwestern Medical Center, University of Texas, Dallas, Texas 75390 (United States)

    2015-05-15

    Purpose: Most clinically deployed strategies for respiratory motion management in lung radiotherapy (e.g., gating and tracking) use external markers that serve as surrogates for tumor motion. However, typical lung phantoms used to validate these strategies are based on a rigid exterior and a rigid or a deformable-interior. Such designs do not adequately represent respiration because the thoracic anatomy deforms internally as well as externally. In order to create a closer approximation of respiratory motion, the authors describe the construction and experimental testing of an externally as well as internally deformable, programmable lung phantom. Methods: The outer shell of a commercially available lung phantom (RS-1500, RSD, Inc.) was used. The shell consists of a chest cavity with a flexible anterior surface, and embedded vertebrae, rib-cage and sternum. A custom-made insert was designed using a piece of natural latex foam block. A motion platform was programmed with sinusoidal and ten patient-recorded lung tumor trajectories. The platform was used to drive a rigid foam “diaphragm” that compressed/decompressed the phantom interior. Experimental characterization comprised of determining the reproducibility and the external–internal correlation of external and internal marker trajectories extracted from kV x-ray fluoroscopy. Experiments were conducted to illustrate three example applications of the phantom—(i) validating the geometric accuracy of the VisionRT surface photogrammetry system; (ii) validating an image registration tool, NiftyReg; and (iii) quantifying the geometric error due to irregular motion in four-dimensional computed tomography (4DCT). Results: The phantom correctly reproduced sinusoidal and patient-derived motion, as well as realistic respiratory motion-related effects such as hysteresis. The reproducibility of marker trajectories over multiple runs for sinusoidal as well as patient traces, as characterized by fluoroscopy, was within 0

  4. Design and fabrication of a realistic anthropomorphic heterogeneous head phantom for MR purposes.

    Directory of Open Access Journals (Sweden)

    Sossena Wood

    Full Text Available The purpose of this study is to design an anthropomorphic heterogeneous head phantom that can be used for MRI and other electromagnetic applications.An eight compartment, physical anthropomorphic head phantom was developed from a 3T MRI dataset of a healthy male. The designed phantom was successfully built and preliminarily evaluated through an application that involves electromagnetic-tissue interactions: MRI (due to it being an available resource. The developed phantom was filled with media possessing electromagnetic constitutive parameters that correspond to biological tissues at ~297 MHz. A preliminary comparison between an in-vivo human volunteer (based on whom the anthropomorphic head phantom was created and various phantoms types, one being the anthropomorphic heterogeneous head phantom, were performed using a 7 Tesla human MRI scanner.Echo planar imaging was performed and minimal ghosting and fluctuations were observed using the proposed anthropomorphic phantom. The magnetic field distributions (during MRI experiments at 7 Tesla and the scattering parameter (measured using a network analyzer were most comparable between the anthropomorphic heterogeneous head phantom and an in-vivo human volunteer.The developed anthropomorphic heterogeneous head phantom can be used as a resource to various researchers in applications that involve electromagnetic-biological tissue interactions such as MRI.

  5. Agency over Phantom Limb Enhanced by Short-Term Mirror Therapy.

    Science.gov (United States)

    Imaizumi, Shu; Asai, Tomohisa; Koyama, Shinichi

    2017-01-01

    Most amputees experience phantom limb, whereby they feel that the amputated limb is still present. In some cases, these experiences include pain that can be alleviated by "mirror therapy." Mirror therapy consists of superimposing a mirrored image of the moving intact limb onto the phantom limb. This therapy provides a closed loop between the motor command to the amputated limb and its predicted visual feedback. This loop is also involved in the sense of agency, a feeling of controlling one's own body. However, it is unclear how mirror therapy is related to the sense of agency over a phantom limb. Using mirror therapy, we investigated phantom limb pain and the senses of agency and ownership (i.e., a feeling of having one's own body) of the phantom limb. Nine upper-limb amputees, five of whom reported recent phantom limb pain, underwent a single 15-min trial of mirror therapy. Before and after the trial, the participants completed a questionnaire regarding agency, ownership, and pain related to their phantom limb. They reported that the sense of agency over the phantom limb increased following the mirror therapy trial, while the ownership slightly increased but not as much as did the agency. The reported pain did not change; that is, it was comparably mild before and after the trial. These results suggest that short-term mirror therapy can, at least transiently, selectively enhance the sense of agency over a phantom limb, but may not alleviate phantom limb pain.

  6. Simultaneous calibration phantom commission and geometry calibration in cone beam CT

    Science.gov (United States)

    Xu, Yuan; Yang, Shuai; Ma, Jianhui; Li, Bin; Wu, Shuyu; Qi, Hongliang; Zhou, Linghong

    2017-09-01

    Geometry calibration is a vital step for describing the geometry of a cone beam computed tomography (CBCT) system and is a prerequisite for CBCT reconstruction. In current methods, calibration phantom commission and geometry calibration are divided into two independent tasks. Small errors in ball-bearing (BB) positioning in the phantom-making step will severely degrade the quality of phantom calibration. To solve this problem, we propose an integrated method to simultaneously realize geometry phantom commission and geometry calibration. Instead of assuming the accuracy of the geometry phantom, the integrated method considers BB centers in the phantom as an optimized parameter in the workflow. Specifically, an evaluation phantom and the corresponding evaluation contrast index are used to evaluate geometry artifacts for optimizing the BB coordinates in the geometry phantom. After utilizing particle swarm optimization, the CBCT geometry and BB coordinates in the geometry phantom are calibrated accurately and are then directly used for the next geometry calibration task in other CBCT systems. To evaluate the proposed method, both qualitative and quantitative studies were performed on simulated and realistic CBCT data. The spatial resolution of reconstructed images using dental CBCT can reach up to 15 line pair cm-1. The proposed method is also superior to the Wiesent method in experiments. This paper shows that the proposed method is attractive for simultaneous and accurate geometry phantom commission and geometry calibration.

  7. Simultaneous calibration phantom commission and geometry calibration in cone beam CT.

    Science.gov (United States)

    Xu, Yuan; Yang, Shuai; Ma, Jianhui; Li, Bin; Wu, Shuyu; Qi, Hongliang; Zhou, Linghong

    2017-08-09

    Geometry calibration is a vital step for describing the geometry of a cone beam computed tomography (CBCT) system and is a prerequisite for CBCT reconstruction. In current methods, calibration phantom commission and geometry calibration are divided into two independent tasks. Small errors in ball-bearing (BB) positioning in the phantom-making step will severely degrade the quality of phantom calibration. To solve this problem, we propose an integrated method to simultaneously realize geometry phantom commission and geometry calibration. Instead of assuming the accuracy of the geometry phantom, the integrated method considers BB centers in the phantom as an optimized parameter in the workflow. Specifically, an evaluation phantom and the corresponding evaluation contrast index are used to evaluate geometry artifacts for optimizing the BB coordinates in the geometry phantom. After utilizing particle swarm optimization, the CBCT geometry and BB coordinates in the geometry phantom are calibrated accurately and are then directly used for the next geometry calibration task in other CBCT systems. To evaluate the proposed method, both qualitative and quantitative studies were performed on simulated and realistic CBCT data. The spatial resolution of reconstructed images using dental CBCT can reach up to 15 line pair cm-1. The proposed method is also superior to the Wiesent method in experiments. This paper shows that the proposed method is attractive for simultaneous and accurate geometry phantom commission and geometry calibration.

  8. Measuring absorbed dose for i-CAT CBCT examinations in child, adolescent and adult phantoms.

    Science.gov (United States)

    Choi, E; Ford, N L

    2015-01-01

    Design and construct child and adolescent head phantoms to measure the absorbed doses imparted during dental CBCT and compare with the absorbed dose measured in an adult phantom. A child phantom was developed to represent the smallest patients receiving CBCT, usually for craniofacial developmental concerns, and an adolescent phantom was developed to represent healthy orthodontic patients. Absorbed doses were measured using a thimble ionization chamber for the custom-built child and adolescent phantoms and compared with measurements using a commercially available adult phantom. Imaging was performed with an i-CAT Next Generation (Imaging Sciences International, Hatfield, PA) CBCT using two different fields of view covering the craniofacial complex (130 mm high) or maxilla/mandible (60 mm high). Measured absorbed doses varied depending on the location of the ionization chamber within the phantoms. For CBCT images obtained using the same protocol for all phantoms, the highest absorbed dose was measured in all locations of the small child phantom. The lowest absorbed dose was measured in the adult phantom. Images were obtained with the same protocol for the adult, adolescent and child phantoms. A consistent trend was observed with the highest absorbed dose being measured in the smallest phantom (child), while the lowest absorbed dose was measured in the largest phantom (adult). This study demonstrates the importance of child-sizing the dose by using dedicated paediatric protocols optimized for the imaging task, which is critical as children are more sensitive to harmful effects of radiation and have a longer life-span post-irradiation for radiation-induced symptoms to develop than do adults.

  9. A methodology to develop computational phantoms with adjustable posture for WBC calibration.

    Science.gov (United States)

    Fonseca, T C Ferreira; Bogaerts, R; Hunt, John; Vanhavere, F

    2014-11-21

    A Whole Body Counter (WBC) is a facility to routinely assess the internal contamination of exposed workers, especially in the case of radiation release accidents. The calibration of the counting device is usually done by using anthropomorphic physical phantoms representing the human body. Due to such a challenge of constructing representative physical phantoms a virtual calibration has been introduced. The use of computational phantoms and the Monte Carlo method to simulate radiation transport have been demonstrated to be a worthy alternative. In this study we introduce a methodology developed for the creation of realistic computational voxel phantoms with adjustable posture for WBC calibration. The methodology makes use of different software packages to enable the creation and modification of computational voxel phantoms. This allows voxel phantoms to be developed on demand for the calibration of different WBC configurations. This in turn helps to study the major source of uncertainty associated with the in vivo measurement routine which is the difference between the calibration phantoms and the real persons being counted. The use of realistic computational phantoms also helps the optimization of the counting measurement. Open source codes such as MakeHuman and Blender software packages have been used for the creation and modelling of 3D humanoid characters based on polygonal mesh surfaces. Also, a home-made software was developed whose goal is to convert the binary 3D voxel grid into a MCNPX input file. This paper summarizes the development of a library of phantoms of the human body that uses two basic phantoms called MaMP and FeMP (Male and Female Mesh Phantoms) to create a set of male and female phantoms that vary both in height and in weight. Two sets of MaMP and FeMP phantoms were developed and used for efficiency calibration of two different WBC set-ups: the Doel NPP WBC laboratory and AGM laboratory of SCK-CEN in Mol, Belgium.

  10. Quality assurance phantoms for cone beam computed tomography: a systematic literature review.

    Science.gov (United States)

    de Oliveira, Marcus V L; Wenzel, Ann; Campos, Paulo S F; Spin-Neto, Rubens

    2017-03-01

    To undertake a systematic review on quality assurance (QA) phantoms for CBCT imaging, including studies on the development and application of phantoms. The MEDLINE (PubMed) bibliographic database was searched until May 2016 for studies evaluating the development and use of phantoms in CBCT image QA. The search strategy was restricted to English language publications using the following combined terms: (Cone Beam CT) OR (Cone Beam Computed Tomography) OR (Cone-Beam Computed Tomography) OR (CBCT) AND (quality OR phantom). It was assessed which of the six image quality parameters stated by the European Commission could be evaluated with each phantom and which of them actually were. The search strategy yielded 37 studies, which had developed and used (25 studies) or only used (12 studies) a phantom in CBCT image QA. According to the literature, in 7 phantoms, it is possible to evaluate 4 or more image quality parameters while in 11 phantoms, merely 1 parameter can be evaluated. Only two phantoms permit the evaluation of the six image quality parameters stated by the European Commission. The parameters, which can most often be evaluated using a phantom, are image density values, spatial resolution and geometric accuracy. The SEDENTEXCT phantom was used most frequently. In two studies, all quality parameters suggested by the European Commission were evaluated. QA phantoms rarely allow all image quality parameters stated by the European Commission to be evaluated. Furthermore, alternative phantoms, which allow all image quality parameters to be evaluated in a single exposure, even for a small field of view, should be developed.

  11. Phantom motor execution facilitated by machine learning and augmented reality as treatment for phantom limb pain: a single group, clinical trial in patients with chronic intractable phantom limb pain.

    Science.gov (United States)

    Ortiz-Catalan, Max; Guðmundsdóttir, Rannveig A; Kristoffersen, Morten B; Zepeda-Echavarria, Alejandra; Caine-Winterberger, Kerstin; Kulbacka-Ortiz, Katarzyna; Widehammar, Cathrine; Eriksson, Karin; Stockselius, Anita; Ragnö, Christina; Pihlar, Zdenka; Burger, Helena; Hermansson, Liselotte

    2016-12-10

    Phantom limb pain is a debilitating condition for which no effective treatment has been found. We hypothesised that re-engagement of central and peripheral circuitry involved in motor execution could reduce phantom limb pain via competitive plasticity and reversal of cortical reorganisation. Patients with upper limb amputation and known chronic intractable phantom limb pain were recruited at three clinics in Sweden and one in Slovenia. Patients received 12 sessions of phantom motor execution using machine learning, augmented and virtual reality, and serious gaming. Changes in intensity, frequency, duration, quality, and intrusion of phantom limb pain were assessed by the use of the numeric rating scale, the pain rating index, the weighted pain distribution scale, and a study-specific frequency scale before each session and at follow-up interviews 1, 3, and 6 months after the last session. Changes in medication and prostheses were also monitored. Results are reported using descriptive statistics and analysed by non-parametric tests. The trial is registered at ClinicalTrials.gov, number NCT02281539. Between Sept 15, 2014, and April 10, 2015, 14 patients with intractable chronic phantom limb pain, for whom conventional treatments failed, were enrolled. After 12 sessions, patients showed statistically and clinically significant improvements in all metrics of phantom limb pain. Phantom limb pain decreased from pre-treatment to the last treatment session by 47% (SD 39; absolute mean change 1·0 [0·8]; p=0·001) for weighted pain distribution, 32% (38; absolute mean change 1·6 [1·8]; p=0·007) for the numeric rating scale, and 51% (33; absolute mean change 9·6 [8·1]; p=0·0001) for the pain rating index. The numeric rating scale score for intrusion of phantom limb pain in activities of daily living and sleep was reduced by 43% (SD 37; absolute mean change 2·4 [2·3]; p=0·004) and 61% (39; absolute mean change 2·3 [1·8]; p=0·001), respectively. Two of four

  12. miR-9: a versatile regulator of neurogenesis

    Directory of Open Access Journals (Sweden)

    Marion Coolen

    2013-11-01

    Full Text Available Soon after its discovery, microRNA-9 (miR-9 attracted the attention of neurobiologists, since it is one of the most highly expressed microRNAs in the developing and adult vertebrate brain. Functional analyses in different vertebrate species have revealed a prominent role of this microRNA in balancing proliferation in embryonic neural progenitor populations. Key transcriptional regulators such as FoxG1, Hes1 or Tlx, were identified as direct targets of miR-9, placing it at the core of the gene network controlling the progenitor state. Recent data also suggest that this function could extend to adult neural stem cells. Other studies point to a role of miR-9 in differentiated neurons. Moreover miR-9 has been implicated in human brain pathologies, either displaying a protective role, such as in Progeria, or participating in disease progression in brain cancers. Altogether functional studies highlight a prominent feature of this highly conserved microRNA, its functional versatility, both along its evolutionary history and across cellular contexts.

  13. Scalable and versatile graphene functionalized with the Mannich condensate.

    Science.gov (United States)

    Liao, Ruijuan; Tang, Zhenghai; Lin, Tengfei; Guo, Baochun

    2013-03-01

    The functionalized graphene (JTPG) is fabricated by chemical conversion of graphene oxide (GO), using tea polyphenols (TP) as the reducer and stabilizer, followed by further derivatization through the Mannich reaction between the pyrogallol groups on TP and Jeffamine M-2070. JTPG exhibits solubility in a broad spectrum of solvents, long-term stability and single-layered dispersion in water and organic solvents, which are substantiated by AFM, TEM, and XRD. The paper-like JTPG hybrids prepared by vacuum-assisted filtration exhibits an unusual combination of high toughness (tensile strength of ~275 MPa and break strain of ~8%) and high electrical conductivity (~700 S/m). Still, JTPG is revealed to be very promising in the fabrication of polymer/graphene composites due to the excellent solubility in the solvent with low boiling point and low toxicity. Accordingly, as an example, nitrile rubber/JTPG composites are fabricated by the solution compounding in acetone. The resulted composite shows low threshold percolation at 0.23 vol.% of graphene. The versatilities both in dispersibility and performance, together with the scalable process of JTPG, enable a new way to scale up the fabrication of the graphene-based polymer composites or hybrids with high performance.

  14. Soluble Lead and Bismuth Chalcogenidometallates: Versatile Solders for Thermoelectric Materials

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Hao [Department; Son, Jae Sung [Department; School; Dolzhnikov, Dmitriy S. [Department; Filatov, Alexander S. [Department; Hazarika, Abhijit [Department; Wang, Yuanyuan [Department; Hudson, Margaret H. [Department; Sun, Cheng-Jun [Advanced; Chattopadhyay, Soma [Physical; Talapin, Dmitri V. [Department; Center

    2017-07-27

    Here we report the syntheses of largely unexplored lead and bismuth chalcogenidometallates in the solution phase. Using N2H4 as the solvent, new compounds such as K6Pb3Te6·7N2H4 were obtained. These soluble molecular compounds underwent cation exchange processes using resin chemistry, replacing Na+ or K+ by decomposable N2H5+ or tetraethylammonium cations. They also transformed into stoichiometric lead and bismuth chalcogenide nanomaterials with the addition of metal salts. Such a versatile chemistry led to a variety of composition-matched solders to join lead and bismuth chalcogenides and tune their charge transport properties at the grain boundaries. Solution-processed thin films composed of Bi0.5Sb1.5Te3 microparticles soldered by (N2H5)6Bi0.5Sb1.5Te6 exhibited thermoelectric power factors (~28 μW/cm K2) comparable to those in vacuum-deposited Bi0.5Sb1.5Te3 films. The soldering effect can also be integrated with attractive fabrication techniques for thermoelectric modules, such as screen printing, suggesting the potential of these solders in the rational design of printable and moldable thermoelectrics.

  15. A Versatile Software Program for Sampling Sferics and More

    Science.gov (United States)

    Stanley, M. A.; Lyons, W. A.; Cummer, S. A.; Jaugey, N.

    2008-12-01

    In 2004, a data acquisition program was written to sample and store sferic waveforms for the upgraded Los Alamos Sferic Array (LASA). The program acquired data using the 20MHz PCI-DAS4020/12 Measurement Computing (MC) board on the stable Linux operating system. The capabilities of this original program have been described elsewhere [Stanley et al., 2004; Shao et al., 2006]. Starting in 2006, this program was modified and enhanced to support data acquisition for a new Charge Moment Change Network (CMCN) which detects and quantifies impulsive charge moment changes of potential sprite-producing lightning discharges in near real-time. Some of the more notable modifications included the addition of low-pass filtered continuous data output capabilities as well as support for National Instruments (NI) boards. The continuous data output was particularly well suited for the unambiguous detection of sferics with slow tails which are often found around the time of sprites and especially sprite halos. The program also utilizes a shared memory architecture which gives it even more versatility in real-time processing as well as enables other modes of data acquisition. In 2008, the program was updated to utilize the Linux Comedi drivers in place of the previous MC and NI drivers. With this modification, the program now supports an even wider variety of data acquisition boards and also runs on the latest Linux distributions.

  16. Sapporo2: a versatile direct N-body library

    Science.gov (United States)

    Bédorf, Jeroen; Gaburov, Evghenii; Portegies Zwart, Simon

    2015-10-01

    Astrophysical direct N-body methods have been one of the first production algorithms to be implemented using NVIDIA's CUDA architecture. Now, almost seven years later, the GPU is the most used accelerator device in astronomy for simulating stellar systems. In this paper we present the implementation of the Sapporo2 N-body library, which allows researchers to use the GPU for N-body simulations with little to no effort. The first version, released five years ago, is actively used, but lacks advanced features and versatility in numerical precision and support for higher order integrators. In this updated version we have rebuilt the code from scratch and added support for OpenCL, multi-precision and higher order integrators. We show how to tune these codes for different GPU architectures and present how to continue utilizing the GPU optimal even when only a small number of particles (N < 100) is integrated. This careful tuning allows Sapporo2 to be faster than Sapporo1 even with the added options and double precision data loads. The code runs on a range of NVIDIA and AMD GPUs in single and double precision accuracy. With the addition of OpenCL support the library is also able to run on CPUs and other accelerators that support OpenCL.

  17. TriPleX: a versatile dielectric photonic platform

    Science.gov (United States)

    Wörhoff, Kerstin; Heideman, René G.; Leinse, Arne; Hoekman, Marcel

    2015-04-01

    Photonic applications based on planar waveguide technology impose stringent requirements on properties such as optical propagation losses, light coupling to optical fibers, integration density, as well as on reliability and reproducibility. The latter is correlated to a high level of control of the refractive index and waveguide geometry. In this paper, we review a versatile dielectric waveguide platform, called TriPleX, which is based on alternating silicon nitride and silicon dioxide films. Fabrication with CMOS-compatible equipment based on low-pressure chemical vapor deposition enables the realization of stable material compositions being a prerequisite to the control of waveguide properties and modal shape. The transparency window of both materials allows for the realization of low-loss waveguides over a wide wavelength range (400 nm-2.35 μm). Propagation losses as low as 5×10-4 dB/cm are reported. Three basic geometries (box shell, double stripe, and filled box) can be distinguished. A specific tapering technology is developed for on-chip, low-loss (functional complexity as well as for hybrid integration with other photonic platforms such as InP and SOI. The functionality of the TriPleX platform is captured by verified basic building blocks. The corresponding library and associated design kit is available for multi-project wafer (MPW) runs. Several applications of this platform technology in communications, biomedicine, sensing, as well as a few special fields of photonics are treated in more detail.

  18. Bits and q-bits as versatility measures

    Directory of Open Access Journals (Sweden)

    José R.C. Piqueira

    2004-06-01

    Full Text Available Using Shannon information theory is a common strategy to measure any kind of variability in a signal or phenomenon. Some methods were developed to adapt information entropy measures to bird song data trying to emphasize its versatility aspect. This classical approach, using the concept of bit, produces interesting results. Now, the original idea developed in this paper is to use the quantum information theory and the quantum bit (q-bit concept in order to provide a more complete vision of the experimental results.Usar a teoria da informação de Shannon é uma estratégia comum para medir todo tipo de variabilidade em um sinal ou fenômeno. Alguns métodos foram desenvolvidos para adaptar a medida de entropia informacional a dados de cantos de pássaro, tentando enfatizar seus aspectos de versatilidade. Essa abordagem clássica, usando o conceito de bit, produz resultados interessantes. Agora, a idéia original desenvolvida neste artigo é usar a teoria quântica da informação e o conceito de q-bit, com a finalidade de proporcionar uma visão mais completa dos resultados experimentais.

  19. Exploring the versatility of gingiva-colored composite

    Directory of Open Access Journals (Sweden)

    Paryag AA

    2016-04-01

    Full Text Available Amit A Paryag,1 Reisha N Rafeek,1 Melissa S Mankee,2 Jenai Lowe1 1School of Dentistry, The University of the West Indies, Mount Hope, 2Tooth Haven Dental Studio, D'Abadie, Trinidad and Tobago Abstract: Gingival recession has a diverse etiology. The consequences may include gingivitis, periodontitis, and hypersensitivity. Whereas the management can include surgical treatment options, sometimes a more conservative, yet still esthetic approach may be required. The use of gingiva-colored composites provides one such alternative and can be applied to varying presentations of the problem. While surgical treatment can be successful in re-creating favorable esthetic anatomy as well as achieving accurate tissue contour in cases when minor amounts of tissue are reconstructed, long-term results vary because of the vascularity and complexity of the interdental space. Factors such as cost, healing time, discomfort, and variable long-term results make surgery an unpopular choice. If tooth-colored restorative materials are utilized to restore cervical tooth exposure as a result of severe recession, the disproportionate appearance of the visible crown may give a dissatisfying result. Gingiva-colored composite provides dental practitioners with a versatile material that can be used to directly restore cervical defects caused by gingival recession, thus correcting the appearance of the gingival anatomy. It offers a treatment option that may increase patient satisfaction through the provision of a cost-effective, minimally invasive solution with highly esthetic results. Keywords: gingiva composite, cervical restoration, esthetics

  20. Collinear technology for holographic versatile disc (HVD) system

    Science.gov (United States)

    Tan, Xiaodi; Horimai, Hideyoshi; Shimura, Tsutomu; Ichimura, Shotaro; Fujimura, Ryushi; Kuroda, Kazuo

    2006-09-01

    Holographic Versatile Disc (HVD TM) using Collinear TM Technologies is proposed by OPTWARE Corporation, in which the information and reference beams are displayed co-axially by the same SLM. With this unique configuration the optical pickup can be designed as small as the DVD's, and can be placed on one side of the recording disc. In HVD TM structure, the pre-formatted meta-data reflective layer is used for the focus/tracking servo and reading address information, and the dichroic mirror layer is used for detecting holographic recording information without interfering with the preformatted information. A 2-dimensional digital page data format is used and the shift-multiplexing method is employed to increased recording density of HVD TM. Experimental and theoretical studies suggest that the holographic material is very effective to increased recording density of the system. As the servo technology is being introduced to control the objective lens to be maintained precisely to the disc in the recording and the reconstructing process, a vibration isolator is no longer necessary. HVD TM will be compatible with existing disc storage systems, like CD and DVD, and enable us to expand its applications into other optical information storage systems.

  1. Versatile genetic tool box for the crenarchaeote Sulfolobus acidocaldarius

    Directory of Open Access Journals (Sweden)

    Michaela eWagner

    2012-06-01

    Full Text Available For reverse genetic approaches inactivation or selective modification of genes are required to elucidate their putative function. Sulfolobus acidocaldarius is a thermoacidophilic Crenarchaeon which grows optimally at 76 °C and pH 3. As many antibiotics do not withstand these conditions the development of a genetic system in this organism is dependent on auxotrophies. Therefore we constructed a pyrE deletion mutant of S. acidocaldarius wild type strain DSM639 missing 322 bp called MW001. Using this strain as the base, we describe here different methods using single as well as double crossover events to obtain markerless deletion mutants, tag genes genomically and ectopically integrate foreign DNA into MW001. These methods enable us to construct single, double and triple deletions strains that can still be complemented with the pRN1 based expression vector. Taken together we have developed a versatile and robust genetic tool box for the crenarchaeote Sulfolobus acidocaldarius that will promote the study of unknown gene functions in this organism and makes this organism a suitable host for synthetic biology approaches.

  2. Versatile Molecular Silver Ink Platform for Printed Flexible Electronics.

    Science.gov (United States)

    Kell, Arnold J; Paquet, Chantal; Mozenson, Olga; Djavani-Tabrizi, Iden; Deore, Bhavana; Liu, Xiangyang; Lopinski, Gregory P; James, Robert; Hettak, Khelifa; Shaker, Jafar; Momciu, Adrian; Ferrigno, Julie; Ferrand, Olivier; Hu, Jian Xiong; Lafrenière, Sylvie; Malenfant, Patrick R L

    2017-05-24

    A silver molecular ink platform formulated for screen, inkjet, and aerosol jet printing is presented. A simple formulation comprising silver neodecanoate, ethyl cellulose, and solvent provides improved performance versus that of established inks, yet with improved economics. Thin, screen-printed traces with exceptional electrical (inks. Low surface roughness, submicron thicknesses, and line widths as narrow as 41 μm outperform commercial ink benchmarks based on flakes or nanoparticles. These traces are mechanically robust to flexing and creasing (less than 10% change in resistance) and bind strongly to epoxy-based adhesives. Thin traces are remarkably conformal, enabling fully printed metal-insulator-metal band-pass filters. The versatility of the molecular ink platform enables an aerosol jet-compatible ink that yields conductive features on glass with 2× bulk resistivity and strong adhesion to various plastic substrates. An inkjet formulation is also used to print top source/drain contacts and demonstrate printed high-mobility thin film transistors (TFTs) based on semiconducting single-walled carbon nanotubes. TFTs with mobility values of ∼25 cm2 V-1 s-1 and current on/off ratios >104 were obtained, performance similar to that of evaporated metal contacts in analogous devices.

  3. Versatile bioelectronic interfaces on flexible non-conductive substrates.

    Science.gov (United States)

    Hassler, Brian L; Amundsen, Ted J; Zeikus, J Gregory; Lee, Ilsoon; Worden, Robert M

    2008-05-15

    Bioelectronic interfaces that establish electrical communication between redox enzymes and electrodes have potential applications as biosensors, biocatalytic reactors, and biological fuel cells. These interfaces are commonly formed on gold films deposited using physical vapor deposition (PVD) or chemical vapor deposition (CVD). PVD and CVD require deposition of a primer layer, such as titanium or chromium, and require the use of expensive equipment and cannot be used on a wide range of substrates. This paper describes a versatile new bench-top method to form bioelectronic interfaces containing a gold film, electron mediator, cofactor, and dehydrogenase enzyme (secondary alcohol dehydrogenase, and sorbitol dehydrogenase) on nonconductive substrates such as polystyrene and glass. The method combines layer-by-layer deposition of polyelectrolytes, electroless metal deposition, and directed molecular self-assembly. Cyclic voltammetry, chronoamperometry, field emission X-ray dispersive spectroscopy, scanning electron microscopy, and atomic force microscopy were used to characterize the bioelectronic interfaces. Interfaces formed on flexible polystyrene slides were shown to retain their activity after bending to a radius of curvature of 18mm, confirming that the approach can be applied on cheap and flexible substrates for applications where traditional wafer-scale electronics is not suitable, such as personal or structural health monitors and rolled microtube biosensors.

  4. 3D printing of versatile reactionware for chemical synthesis.

    Science.gov (United States)

    Kitson, Philip J; Glatzel, Stefan; Chen, Wei; Lin, Chang-Gen; Song, Yu-Fei; Cronin, Leroy

    2016-05-01

    In recent decades, 3D printing (also known as additive manufacturing) techniques have moved beyond their traditional applications in the fields of industrial manufacturing and prototyping to increasingly find roles in scientific research contexts, such as synthetic chemistry. We present a general approach for the production of bespoke chemical reactors, termed reactionware, using two different approaches to extrusion-based 3D printing. This protocol describes the printing of an inert polypropylene (PP) architecture with the concurrent printing of soft material catalyst composites, using two different 3D printer setups. The steps of the PROCEDURE describe the design and preparation of a 3D digital model of the desired reactionware device and the preparation of this model for use with fused deposition modeling (FDM) type 3D printers. The protocol then further describes the preparation of composite catalyst-silicone materials for incorporation into the 3D-printed device and the steps required to fabricate a reactionware device. This combined approach allows versatility in the design and use of reactionware based on the specific needs of the experimental user. To illustrate this, we present a detailed procedure for the production of one such reactionware device that will result in the production of a sealed reactor capable of effecting a multistep organic synthesis. Depending on the design time of the 3D model, and including time for curing and drying of materials, this procedure can be completed in ∼3 d.

  5. Versatility of cyclodextrins in self-assembly systems of amphiphiles.

    Science.gov (United States)

    Jiang, Lingxiang; Yan, Yun; Huang, Jianbin

    2011-11-14

    Recently, cyclodextrins (CDs) were found to play important yet complicated (or even apparently opposite sometimes) roles in self-assembly systems of amphiphiles or surfactants. Herein, we try to review and clarify the versatility of CDs in surfactant assembly systems by 1) classifying the roles played by CDs into two groups (modulator and building unit) and four subgroups (destructive and constructive modulators, amphiphilic and unamphiphilic building units), 2) comparing these subgroups, and 3) analyzing mechanisms. As a modulator, although CDs by themselves do not participate into the final surfactant aggregates, they can greatly affect the aggregates in two ways. In most cases CDs will destroy the aggregates by depleting surfactant molecules from the aggregates (destructive), or in certain cases CDs can promote the aggregates to grow by selectively removing the less-aggregatable surfactant molecules from the aggregates (constructive). As an amphiphilic building unit, CDs can be chemically (by chemical bonds) or physically (by host-guest interaction) attached to a hydrophobic moiety, and the resultant compounds act as classic amphiphiles. As an unamphiphilic building unit, CD/surfactant complexes or even CDs on their own can assemble into aggregates in an unconventional, unamphiphilic manner driven by CD-CD H-bonds. Moreover, special emphasis is put on two recently appeared aspects: the constructive modulator and unamphiphilic building unit. Copyright © 2011 Elsevier B.V. All rights reserved.

  6. Zebrafish: A Versatile Animal Model for Fertility Research

    Directory of Open Access Journals (Sweden)

    Jing Ying Hoo

    2016-01-01

    Full Text Available The utilization of zebrafish in biomedical research is very common in the research world nowadays. Today, it has emerged as a favored vertebrate organism for the research in science of reproduction. There is a significant growth in amount numbers of scientific literature pertaining to research discoveries in reproductive sciences in zebrafish. It has implied the importance of zebrafish in this particular field of research. In essence, the current available literature has covered from the very specific brain region or neurons of zebrafish, which are responsible for reproductive regulation, until the gonadal level of the animal. The discoveries and findings have proven that this small animal is sharing a very close/similar reproductive system with mammals. More interestingly, the behavioral characteristics and along with the establishment of animal courtship behavior categorization in zebrafish have laid an even stronger foundation and firmer reason on the suitability of zebrafish utilization in research of reproductive sciences. In view of the immense importance of this small animal for the development of reproductive sciences, this review aimed at compiling and describing the proximate close similarity of reproductive regulation on zebrafish and human along with factors contributing to the infertility, showing its versatility and its potential usage for fertility research.

  7. Versatile protein tagging in cells with split fluorescent protein.

    Science.gov (United States)

    Kamiyama, Daichi; Sekine, Sayaka; Barsi-Rhyne, Benjamin; Hu, Jeffrey; Chen, Baohui; Gilbert, Luke A; Ishikawa, Hiroaki; Leonetti, Manuel D; Marshall, Wallace F; Weissman, Jonathan S; Huang, Bo

    2016-03-18

    In addition to the popular method of fluorescent protein fusion, live cell protein imaging has now seen more and more application of epitope tags. The small size of these tags may reduce functional perturbation and enable signal amplification. To address their background issue, we adapt self-complementing split fluorescent proteins as epitope tags for live cell protein labelling. The two tags, GFP11 and sfCherry11 are derived from the eleventh β-strand of super-folder GFP and sfCherry, respectively. The small size of FP11-tags enables a cost-effective and scalable way to insert them into endogenous genomic loci via CRISPR-mediated homology-directed repair. Tandem arrangement FP11-tags allows proportional enhancement of fluorescence signal in tracking intraflagellar transport particles, or reduction of photobleaching for live microtubule imaging. Finally, we show the utility of tandem GFP11-tag in scaffolding protein oligomerization. These experiments illustrate the versatility of FP11-tag as a labelling tool as well as a multimerization-control tool for both imaging and non-imaging applications.

  8. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms.

    Science.gov (United States)

    Bieniosek, Matthew F; Lee, Brian J; Levin, Craig S

    2015-10-01

    Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial "Micro Deluxe" phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. This work shows that 3D printed phantoms can be functionally equivalent to

  9. Technical Note: Characterization of custom 3D printed multimodality imaging phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Bieniosek, Matthew F. [Department of Electrical Engineering, Stanford University, 350 Serra Mall, Stanford, California 94305 (United States); Lee, Brian J. [Department of Mechanical Engineering, Stanford University, 440 Escondido Mall, Stanford, California 94305 (United States); Levin, Craig S., E-mail: cslevin@stanford.edu [Departments of Radiology, Physics, Bioengineering and Electrical Engineering, Stanford University, 300 Pasteur Dr., Stanford, California 94305-5128 (United States)

    2015-10-15

    Purpose: Imaging phantoms are important tools for researchers and technicians, but they can be costly and difficult to customize. Three dimensional (3D) printing is a widely available rapid prototyping technique that enables the fabrication of objects with 3D computer generated geometries. It is ideal for quickly producing customized, low cost, multimodal, reusable imaging phantoms. This work validates the use of 3D printed phantoms by comparing CT and PET scans of a 3D printed phantom and a commercial “Micro Deluxe” phantom. This report also presents results from a customized 3D printed PET/MRI phantom, and a customized high resolution imaging phantom with sub-mm features. Methods: CT and PET scans of a 3D printed phantom and a commercial Micro Deluxe (Data Spectrum Corporation, USA) phantom with 1.2, 1.6, 2.4, 3.2, 4.0, and 4.8 mm diameter hot rods were acquired. The measured PET and CT rod sizes, activities, and attenuation coefficients were compared. A PET/MRI scan of a custom 3D printed phantom with hot and cold rods was performed, with photon attenuation and normalization measurements performed with a separate 3D printed normalization phantom. X-ray transmission scans of a customized two level high resolution 3D printed phantom with sub-mm features were also performed. Results: Results show very good agreement between commercial and 3D printed micro deluxe phantoms with less than 3% difference in CT measured rod diameter, less than 5% difference in PET measured rod diameter, and a maximum of 6.2% difference in average rod activity from a 10 min, 333 kBq/ml (9 μCi/ml) Siemens Inveon (Siemens Healthcare, Germany) PET scan. In all cases, these differences were within the measurement uncertainties of our setups. PET/MRI scans successfully identified 3D printed hot and cold rods on PET and MRI modalities. X-ray projection images of a 3D printed high resolution phantom identified features as small as 350 μm wide. Conclusions: This work shows that 3D printed

  10. Comparison of methods for individualized astronaut organ dosimetry: Morphometry-based phantom library versus body contour autoscaling of a reference phantom

    Science.gov (United States)

    Sands, Michelle M.; Borrego, David; Maynard, Matthew R.; Bahadori, Amir A.; Bolch, Wesley E.

    2017-11-01

    One of the hazards faced by space crew members in low-Earth orbit or in deep space is exposure to ionizing radiation. It has been shown previously that while differences in organ-specific and whole-body risk estimates due to body size variations are small for highly-penetrating galactic cosmic rays, large differences in these quantities can result from exposure to shorter-range trapped proton or solar particle event radiations. For this reason, it is desirable to use morphometrically accurate computational phantoms representing each astronaut for a risk analysis, especially in the case of a solar particle event. An algorithm was developed to automatically sculpt and scale the UF adult male and adult female hybrid reference phantom to the individual outer body contour of a given astronaut. This process begins with the creation of a laser-measured polygon mesh model of the astronaut's body contour. Using the auto-scaling program and selecting several anatomical landmarks, the UF adult male or female phantom is adjusted to match the laser-measured outer body contour of the astronaut. A dosimetry comparison study was conducted to compare the organ dose accuracy of both the autoscaled phantom and that based upon a height-weight matched phantom from the UF/NCI Computational Phantom Library. Monte Carlo methods were used to simulate the environment of the August 1972 and February 1956 solar particle events. Using a series of individual-specific voxel phantoms as a local benchmark standard, autoscaled phantom organ dose estimates were shown to provide a 1% and 10% improvement in organ dose accuracy for a population of females and males, respectively, as compared to organ doses derived from height-weight matched phantoms from the UF/NCI Computational Phantom Library. In addition, this slight improvement in organ dose accuracy from the autoscaled phantoms is accompanied by reduced computer storage requirements and a more rapid method for individualized phantom generation

  11. Geometrically complex 3D-printed phantoms for diffuse optical imaging.

    Science.gov (United States)

    Dempsey, Laura A; Persad, Melissa; Powell, Samuel; Chitnis, Danial; Hebden, Jeremy C

    2017-03-01

    Tissue-equivalent phantoms that mimic the optical properties of human and animal tissues are commonly used in diffuse optical imaging research to characterize instrumentation or evaluate an image reconstruction method. Although many recipes have been produced for generating solid phantoms with specified absorption and transport scattering coefficients at visible and near-infrared wavelengths, the construction methods are generally time-consuming and are unable to create complex geometries. We present a method of generating phantoms using a standard 3D printer. A simple recipe was devised which enables printed phantoms to be produced with precisely known optical properties. To illustrate the capability of the method, we describe the creation of an anatomically accurate, tissue-equivalent premature infant head optical phantom with a hollow brain space based on MRI atlas data. A diffuse optical image of the phantom is acquired when a high contrast target is inserted into the hollow space filled with an aqueous scattering solution.

  12. Transportation of reactive oxygen species in a tissue phantom after plasma irradiation

    Science.gov (United States)

    Kawasaki, Toshiyuki; Kuroeda, Gouya; Sei, Ryuhei; Yamaguchi, Masaaki; Yoshinaga, Reishi; Yamashita, Riho; Tasaki, Hikaru; Koga, Kazunori; Shiratani, Masaharu

    2018-01-01

    The transportation of reactive oxygen species (ROSs) in a tissue phantom after plasma irradiation was studied using a two-layered target consisting of a KI-starch gel reagent and an agarose tissue phantom. The two-layered target can visualize the two-dimensional concentration distribution of ROSs after passing through the tissue phantom. ROSs were accumulated in the tissue phantom by the plasma irradiation, and they continued to be transported in the depth direction with the standing time after the plasma irradiation. The amount of ROS after passing through the tissue phantom increased in proportion to both plasma irradiation time and standing time. In this case, the ROS distribution patterns did not depend on these times. The ROS transportation speed after plasma irradiation was 0.05 mm/min in the tissue phantom. The ROS penetration rate depended on the standing time, not on the plasma irradiation time, and it was less than 1%.

  13. Testing gravity of a regular and slowly rotating phantom black hole by quasi-periodic oscillations

    CERN Document Server

    Chen, Songbai; Jing, Jiliang

    2016-01-01

    We extend firstly the regular phantom black hole solution to a slowly rotating black hole case and find that the phantom field depresses the angular velocity of the event horizon and suppresses the super-radiation of black hole. We also probe the dependence of quasi-periodic oscillations frequencies in relativistic precession model on the phantom parameter. With the observation data of GRO J1655-40, we make a constraint on the parameters of the regular and slowly rotating phantom black hole. Our results show that although the best-fit value of the phantom parameter $b$ is small, the allowed value of $b$ in the $1\\sigma$ region is $b<0.619$, which means that the phantom theoretical model can not be excluded by the constraint from quasi-periodic oscillations with the observation data of GRO J1655-40.

  14. Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation

    Energy Technology Data Exchange (ETDEWEB)

    Kinase, S.; Zankl, M.; Kuwabara, J.; Sato, K.; Noguchi, H.; Funabiki, J.; Saito, K

    2003-07-01

    There is a need to calculate specific absorbed fractions (SAFs) in voxel phantoms for internal dosimetry. For this purpose, an EGS4 user code for calculating SAFs using voxel phantoms was developed on the basis of an existing EGS4 user code for external dosimetry (UCPIXEL). In the developed code, the transport of photons, electrons and positrons in voxel phantoms can be simulated, particularly the transport simulations of secondary electrons in voxel phantoms. The evaluated SAFs for the GSF 'Child' voxel phantom using the developed code were found to be in good agreement with the GSF evaluated data. In addition, SAFs in adult voxel phantoms developed at JAERI were evaluated using the developed code and were compared with several published data. It was found that SAFs for organ self-absorption depend on the organ masses and would be affected by differences in the structure of the human body. (author)

  15. Evaluation of specific absorbed fractions in voxel phantoms using Monte Carlo simulation.

    Science.gov (United States)

    Kinase, S; Zankl, M; Kuwabara, J; Sato, K; Noguchi, H; Funabiki, J; Saito, K

    2003-01-01

    There is a need to calculate specific absorbed fractions (SAFs) in voxel phantoms for internal dosimetry. For this purpose, an EGS4 user code for calculating SAFs using voxel phantoms was developed on the basis of an existing EGS4 user code for external dosimetry (UCPIXEL). In the developed code, the transport of photons, electrons and positrons in voxel phantoms can be simulated, particularly the transport simulations of secondary electrons in voxel phantoms. The evaluated SAFs for the GSF 'Child' voxel phantom using the developed code were found to be in good agreement with the GSF evaluated data. In addition, SAFs in adult voxel phantoms developed at JAERI were evaluated using the developed code and were compared with several published data. It was found that SAFs for organ self-absorption depend on the organ masses and would be affected by differences in the structure of the human body.

  16. Realistic phantoms to characterize dosimetry in pediatric CT

    Energy Technology Data Exchange (ETDEWEB)

    Carver, Diana E.; Kost, Susan D.; Fraser, Nicholas D.; Pickens, David R.; Price, Ronald R.; Stabin, Michael G. [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Segars, W.P. [Duke University, Carl E. Ravin Advanced Imaging Laboratories, Durham, NC (United States)

    2017-05-15

    The estimation of organ doses and effective doses for children receiving CT examinations is of high interest. Newer, more realistic anthropomorphic body models can provide information on individual organ doses and improved estimates of effective dose. Previously developed body models representing 50th-percentile individuals at reference ages (newborn, 1, 5, 10 and 15 years) were modified to represent 10th, 25th, 75th and 90th height percentiles for both genders and an expanded range of ages (3, 8 and 13 years). We calculated doses for 80 pediatric reference phantoms from simulated chest-abdomen-pelvis exams on a model of a Philips Brilliance 64 CT scanner. Individual organ and effective doses were normalized to dose-length product (DLP) and fit as a function of body diameter. We calculated organ and effective doses for 80 reference phantoms and plotted them against body diameter. The data were well fit with an exponential function. We found DLP-normalized organ dose to correlate strongly with body diameter (R{sup 2}>0.95 for most organs). Similarly, we found a very strong correlation with body diameter for DLP-normalized effective dose (R{sup 2}>0.99). Our results were compared to other studies and we found average agreement of approximately 10%. We provide organ and effective doses for a total of 80 reference phantoms representing normal-stature children ranging in age and body size. This information will be valuable in replacing the types of vendor-reported doses available. These data will also permit the recording and tracking of individual patient doses. Moreover, this comprehensive dose database will facilitate patient matching and the ability to predict patient-individualized dose prior to examination. (orig.)

  17. Quantitative flow phantom for contrast-enhanced breast tomosynthesis

    Science.gov (United States)

    Nock, Melissa L.; Kempston, Michael P.; Mainprize, James G.; Yaffe, Martin J.

    2007-03-01

    The use of contrast agents can help to overcome a lack of intrinsic radiographic contrast between malignant and benign breast tissue by taking advantage of the properties of tumour angiogenesis. Studies of contrast-enhanced mammography have demonstrated increased lesion conspicuity and have shown that this technique provides information on contrast uptake kinetics. It has been suggested that malignant and benign lesions can be differentiated in part by their uptake kinetics, so this additional data may lead to more accurate diagnoses. Tomosynthesis is a 3D x-ray imaging technique that permits lesion depth localization and increased conspicuity in comparison with 2D x-ray projection techniques. This modality, used in combination with contrast agents, promises to be a sensitive method of breast cancer detection. To develop the technique of contrast-enhanced breast tomosynthesis, a dynamic flow phantom has been constructed to provide the same types of imaging challenges anticipated in the clinical setting. These challenges include a low-contrast tumour space, relevant temporal contrast agent uptake and washout profiles, and a need for quantitative analysis of enhancement levels. The design of a flow phantom will be presented that includes a dynamic tumour space, a background that masks the tumour space in images without contrast enhancement, and flow characteristics that simulate tumour contrast agent uptake and washout kinetics. The system is calibrated to relate signal to concentration of the contrast agent using a well plate filled with iodinated water. Iodine detectability in the flow phantom is evaluated in terms of the signal-difference-to-noise ratio for various tomosynthesis image acquisition parameters including number of acquired angular views, angular extent, and reconstruction voxel size.

  18. Maladaptive plasticity: imprinting of past experiences onto phantom limb schemata.

    Science.gov (United States)

    Giummarra, Melita Joy; Georgiou-Karistianis, Nellie; Nicholls, Michael E R; Gibson, Stephen J; Chou, Michael; Bradshaw, John L

    2011-10-01

    Phantom limb perception is common following amputation, and is sometimes characterised by pain that resembles the characteristics, intensity or location of past pain. We tested Flor's model that phantom pain results from memory for long-lasting znoxious input. We report a questionnaire study of 283 amputees, that explored the experience of painful, non-painful and postural somatosensory memories in the phantom. We explore the impact of pre-amputation pain and impairment duration, and complications in the limb (eg, infection, gangrene, surgery, and vascular disease). Differences in mood, coping and adjustment to amputation are also explored in those with somatosensory pain memories. Our findings support Flor's model, as amputation-related and non-amputation-related pain memories, and non-painful memories comprised pains or sensations that were either enduring/recurring pains or sensations (eg, ingrown toenail, corns, chilblains, arthritis-type pain in winter, night-cramps, or holding a tennis racquet), or resulted from a painful event with a "core-trauma" element (eg, fracture, crushing/penetration injury). Pain memories related to amputation were more common following functional impairment before amputation; infection or surgery prior to amputation; or having diabetic or vascular amputations-which are associated with multiple complications, including neuropathic changes, infection and prior surgery. Furthermore, participants with amputation-related pain memories exhibited higher sensory pain ratings, as well as poorer mood and adjustment to the limitations of amputation. We propose that somatosensory pain memories likely relate to the generation and maintenance of limb representations upon which intense or emotionally powerful past experiences have been imprinted.

  19. iPads in Breast Imaging - A Phantom Study.

    Science.gov (United States)

    Hammon, M; Schlechtweg, P M; Schulz-Wendtland, R; Uder, M; Schwab, S A

    2014-02-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as "uncertain", correct 2 : 1 decisions were classified as "uncertain/readable". In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of "uncertain" fields did not show significant differences. The number of "uncertain" fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of "uncertain/readable" fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens.

  20. iPads in Breast Imaging – A Phantom Study

    Science.gov (United States)

    Hammon, M.; Schlechtweg, P. M.; Schulz-Wendtland, R.; Uder, M.; Schwab, S. A.

    2014-01-01

    Introduction: Modern tablet PCs as the iPad are becoming more and more integrated into medicine. The aim of this study was to evaluate the display quality of iPads regarding digital mammography. Materials and Methods: Three experienced readers compared the display quality of the iPad 2 and 3 with a dedicated 10 megapixel (MP) mammography liquid crystal display (LCD) screen in consensus using the standardized Contrast Detail Mammography (CDMAM) phantom. Phantom fields without agreement between the readers were classified as “uncertain”, correct 2 : 1 decisions were classified as “uncertain/readable”. In a second step display quality of the three reading devices was judged subjectively in a side by side comparison. Results: The 10 MP screen was superior to both iPads in 4 (phantom-)fields and inferior in 2 fields. Comparing the iPads, version 3 was superior in 4 fields and version 2 was superior in 1 field. However these differences were not significant. Total number of “uncertain” fields did not show significant differences. The number of “uncertain” fields was 15 with the 10 MP screen, 16 with the iPad 2 and 17 with the iPad 3 (p > 0.05), the number of “uncertain/readable” fields was 4, 7 and 8, respectively. Subjective image quality of the iPad 3 and the 10 MP screen was rated superior to the iPad 2. Conclusion: The evaluated iPads, especially in version 3, seem to be adequate to display mammograms in a diagnostic quality and thus could be useful e.g. for patient consultation, clinical demonstration or educational and teaching purposes. However primary mammogram reading should still be performed on dedicated large sized reading screens. PMID:24741126

  1. Phantom hand and wrist movements in upper limb amputees are slow but naturally controlled movements.

    Science.gov (United States)

    De Graaf, J B; Jarrassé, N; Nicol, C; Touillet, A; Coyle, T; Maynard, L; Martinet, N; Paysant, J

    2016-01-15

    After limb amputation, patients often wake up with a vivid perception of the presence of the missing limb, called "phantom limb". Phantom limbs have mostly been studied with respect to pain sensation. But patients can experience many other phantom sensations, including voluntary movements. The goal of the present study was to quantify phantom movement kinematics and relate these to intact limb kinematics and to the time elapsed since amputation. Six upper arm and two forearm amputees with various delays since amputation (6months to 32years) performed phantom finger, hand and wrist movements at self-chosen comfortable velocities. The kinematics of the phantom movements was indirectly obtained via the intact limb that synchronously mimicked the phantom limb movements, using a Cyberglove® for measuring finger movements and an inertial measurement unit for wrist movements. Results show that the execution of phantom movements is perceived as "natural" but effortful. The types of phantom movements that can be performed are variable between the patients but they could all perform thumb flexion/extension and global hand opening/closure. Finger extension movements appeared to be 24% faster than finger flexion movements. Neither the number of types of phantom movements that can be executed nor the kinematic characteristics were related to the elapsed time since amputation, highlighting the persistence of post-amputation neural adaptation. We hypothesize that the perceived slowness of phantom movements is related to altered proprioceptive feedback that cannot be recalibrated by lack of visual feedback during phantom movement execution. Copyright © 2015 IBRO. Published by Elsevier Ltd. All rights reserved.

  2. Preliminary Evidence for Training-Induced Changes of Morphology and Phantom Limb Pain

    OpenAIRE

    Sandra Preißler; Désirée Thielemann; Caroline Dietrich; Hofmann, Gunther O; Miltner, Wolfgang H. R.; Thomas Weiss

    2017-01-01

    The aim of this study was to investigate whether a special prosthetic training in phantom limb pain patients aimed at increasing the functional use of the prosthesis leads to neural morphological plasticity of brain structures and a reduction in phantom limb pain. For chronic pain disorders, it was shown that morphological alterations due to pain might become at least partially reversed by pain therapies. Phantom limb pain is a chronic pain disorder that is frequently followed by neural plast...

  3. Quality assessment of digital X-ray chest images using an anthropomorphic chest phantom

    Science.gov (United States)

    Vodovatov, A. V.; Kamishanskaya, I. G.; Drozdov, A. A.; Bernhardsson, C.

    2017-02-01

    The current study is focused on determining the optimal tube voltage for the conventional X-ray digital chest screening examinations, using a visual grading analysis method. Chest images of an anthropomorphic phantom were acquired in posterior-anterior projection on four digital X-ray units with different detector types. X-ray images obtained with an anthropomorphic phantom were accepted by the radiologists as corresponding to a normal human anatomy, hence allowing using phantoms in image quality trials without limitations.

  4. Quantification of breast density using dual-energy mammography with liquid phantom calibration.

    Science.gov (United States)

    Lam, Alfonso R; Ding, Huanjun; Molloi, Sabee

    2014-07-21

    Breast density is a widely recognized potential risk factor for breast cancer. However, accurate quantification of breast density is a challenging task in mammography. The current use of plastic breast-equivalent phantoms for calibration provides limited accuracy in dual-energy mammography due to the chemical composition of the phantom. We implemented a breast-equivalent liquid phantom for dual-energy calibration in order to improve the accuracy of breast density measurement. To design these phantoms, three liquid compounds were chosen: water, isopropyl alcohol, and glycerol. Chemical compositions of glandular and adipose tissues, obtained from NIST database, were used as reference materials. Dual-energy signal of the liquid phantom at different breast densities (0% to 100%) and thicknesses (1 to 8 cm) were simulated. Glandular and adipose tissue thicknesses were estimated from a higher order polynomial of the signals. Our results indicated that the linear attenuation coefficients of the breast-equivalent liquid phantoms match those of the target material. Comparison between measured and known breast density data shows a linear correlation with a slope close to 1 and a non-zero intercept of 7%, while plastic phantoms showed a slope of 0.6 and a non-zero intercept of 8%. Breast density results derived from the liquid calibration phantoms showed higher accuracy than those derived from the plastic phantoms for different breast thicknesses and various tube voltages. We performed experimental phantom studies using liquid phantoms and then compared the computed breast density with those obtained using a bovine tissue model. The experimental data and the known values were in good correlation with a slope close to 1 (∼1.1). In conclusion, our results indicate that liquid phantoms are a reliable alternative for calibration in dual-energy mammography and better reproduce the chemical properties of the target material.

  5. US-tracked steered FUS in a respiratory ex vivo ovine liver phantom

    Directory of Open Access Journals (Sweden)

    Strehlow Jan

    2015-09-01

    Full Text Available Organ motion is a major problem for Focused Ultrasound Surgery (FUS of liver tumors. We present a liver phantom mimicking human respiratory motion (20 mm range, 3 − 7 s/cycle and the evaluation of an ultrasound-tracked steered FUS system on that phantom. Temperature curves are recorded while sonicating in moving and static phantom. The temperature curves correlate well and show the ability of the system to compensate breathing like motion.

  6. Reversible induction of phantom auditory sensations through simulated unilateral hearing loss.

    OpenAIRE

    Schaette, R.; Turtle, C.; Munro, K. J.

    2012-01-01

    Tinnitus, a phantom auditory sensation, is associated with hearing loss in most cases, but it is unclear if hearing loss causes tinnitus. Phantom auditory sensations can be induced in normal hearing listeners when they experience severe auditory deprivation such as confinement in an anechoic chamber, which can be regarded as somewhat analogous to a profound bilateral hearing loss. As this condition is relatively uncommon among tinnitus patients, induction of phantom sounds by a lesser degree ...

  7. Reversible Induction of Phantom Auditory Sensations through Simulated Unilateral Hearing Loss

    OpenAIRE

    Roland Schaette; Charlotte Turtle; Munro, Kevin J.

    2012-01-01

    Tinnitus, a phantom auditory sensation, is associated with hearing loss in most cases, but it is unclear if hearing loss causes tinnitus. Phantom auditory sensations can be induced in normal hearing listeners when they experience severe auditory deprivation such as confinement in an anechoic chamber, which can be regarded as somewhat analogous to a profound bilateral hearing loss. As this condition is relatively uncommon among tinnitus patients, induction of phantom sounds by a lesser degree ...

  8. Unified universe history through phantom extended Chaplygin gas

    CERN Document Server

    Pourhassan, B

    2015-01-01

    We investigate the universe evolution from inflation to late-time acceleration in a unified way, using a two-component fluid constituted from extended Chaplygin gas alongside a phantom scalar field. We extract solutions for the various cosmological eras, focusing on the behavior of the scale factor, the various density parameters and the equation-of-state parameter. Furthermore, we extract and discuss bouncing solutions. Finally, we examine the perturbations of the model, ensuring about their stability and extracting the predictions for the tensor-to-scalar ratio.

  9. X-ray characterization of breast phantom materials

    Energy Technology Data Exchange (ETDEWEB)

    Byng, J.W.; Mainprize, J.G.; Yaffe, M.J. [Department of Medical Biophysics and Radiology, University of Toronto and Imaging Research, Sunnybrook Health Science Centre, 2075 Bayview Avenue, Toronto, Ontario M4N 3M5 (Canada)

    1998-05-01

    A pulse-height spectroscopic technique is used to measure the linear attenuation coefficients of commercially available composite phantom materials designed to simulate the attenuation characteristics of breast fat and breast glandular tissue. The manufacturers have specified the composition of these materials with the goal of matching the linear attenuation coefficients of breast tissues, calculated using the mixture rule. Over the energy range 18 to 100 keV, measurements from these materials are in close agreement with manufacturers' predictions and with previously measured linear attenuation coefficients of breast tissue samples. (author)

  10. Long-term motor cortex stimulation for phantom limb pain.

    Science.gov (United States)

    Pereira, Erlick A C; Moore, Tom; Moir, Liz; Aziz, Tipu Z

    2015-04-01

    We present the long-term course of motor cortex stimulation to relieve a case of severe burning phantom arm pain after brachial plexus injury and amputation. During 16-year follow-up the device continued to provide efficacious analgesia. However, several adjustments of stimulation parameters were required, as were multiple pulse generator changes, antibiotics for infection and one electrode revision due to lead migration. Steady increases in stimulation parameters over time were required. One of the longest follow-ups of motor cortex stimulation is described; the case illustrates challenges and pitfalls in neuromodulation for chronic pain, demonstrating strategies for maintaining analgesia and overcoming tolerance.

  11. Real Time Target Tracking in a Phantom Using Ultrasonic Imaging

    Science.gov (United States)

    Xiao, X.; Corner, G.; Huang, Z.

    In this paper we present a real-time ultrasound image guidance method suitable for tracking the motion of tumors. A 2D ultrasound based motion tracking system was evaluated. A robot was used to control the focused ultrasound and position it at the target that has been segmented from a real-time ultrasound video. Tracking accuracy and precision were investigated using a lesion mimicking phantom. Experiments have been conducted and results show sufficient efficiency of the image guidance algorithm. This work could be developed as the foundation for combining the real time ultrasound imaging tracking and MRI thermometry monitoring non-invasive surgery.

  12. A three-Gaussian fit of phantom scatter correction data.

    Science.gov (United States)

    van Gasteren, J J; van der Laarse, R; Venselaar, J L; Heukelom, S; Jager, H N; van Kleffens, H J; Westermann, C F

    1998-03-01

    The phantom scatter correction factor Sp of megavoltage photon beams can be accurately described using a three-Gaussian fit. The model leads to six parameters, with which Sp(r) is described as a smooth function of the field radius r for beam qualities in the range from 60Co up to 25 MV. The parameters allow Sp values to be calculated at intermediate beam energies and for any field shape. Calculated Sp(X, Y) values for rectangular fields (X, Y) can be subsequently used as reference values to compare with measured Sp(X, Y) values, for example when appraising a new beam.

  13. Geometrothermodynamics of phantom AdS black holes

    Energy Technology Data Exchange (ETDEWEB)

    Quevedo, Hernando [Universidad Nacional Autonoma de Mexico, Instituto de Ciencias Nucleares, Mexico (Mexico); Universita di Roma ' ' La Sapienza' ' , Dipartimento di Fisica ed ICRANet, Rome (Italy); Quevedo, Maria N. [Facultad de Ciencias Basicas, Universidad Militar Nueva Granada, Departamento de Matematicas, Bogota (Colombia); Sanchez, Alberto [CIIDET, Departamento de Posgrado, Queretaro (Mexico)

    2016-03-15

    We show that to investigate the thermodynamic properties of charged phantom spherically symmetric anti-de Sitter black holes, it is necessary to consider the cosmological constant as a thermodynamic variable so that the corresponding fundamental equation is a homogeneous function defined on an extended equilibrium space. We explore all the thermodynamic properties of this class of black holes by using the classical physical approach, based upon the analysis of the fundamental equation, and the alternative mathematical approach as proposed in geometrothermodynamics. We show that both approaches are compatible and lead to equivalent results. (orig.)

  14. Controlled Electrochemical Carboxylation of Graphene To Create a Versatile Chemical Platform for Further Functionalization

    DEFF Research Database (Denmark)

    Bjerglund Pedersen, Emil; Kongsfelt, Mikkel; Shimizu, Kyoko

    2014-01-01

    , this electrochemical method offers a versatile procedure to make all graphene sheets in a multi-layered but expanded structure accessible for functionalization. On a more general level, this approach will provide a versatile way of forming new hybrid materials based on intimate bond coupling to graphene via......An electrochemical approach is introduced for the versatile carboxylation of multi-layered graphene in 0.1 M Bu4NBF4/MeCN. First, the graphene substrate (i.e., graphene chemically vapor-deposited on Ni) is negatively charged at -1.9 V versus Ag/AgI in a degassed solution to allow for intercalation...

  15. Effect of Anatomical Modeling on Space Radiation Dose Estimates: A Comparison of Doses for NASA Phantoms and 5th, 50th, and 95th Percentile UF Hybrid Phantoms

    Science.gov (United States)

    Bahadori, A.; VanBaalen, M.; Shavers, M.; Semones, E.; Dodge, C.; Bolch, W.

    2010-01-01

    The estimate of absorbed dose to individual organs of a space crewmember is affected by the geometry of the anatomical model of the astronaut used in the radiation transport calculation. For astronaut dosimetry, NASA currently uses the computerized anatomical male (CAM) and computerized anatomical female (CAF) stylized phantoms to represent astronauts in its operational radiation dose analyses. These phantoms are available in one size and in two body positions. In contrast, the UF Hybrid Adult Male and Female (UFHADM and UFHADF) phantoms have organ shapes based on actual CT data. The surfaces of these phantoms are defined by non-uniform rational B-spline surfaces, and are thus flexible in terms of body morphometry and extremity positioning. In this study, UFHADM and UFHADF are scaled to dimensions corresponding to 5th, 50th, and 95th percentile (PCTL) male and female astronauts. A ray-tracing program is written in Visual Basic 2008, which is then used to create areal density maps for dose points corresponding to various organs within the phantoms. The areal density maps, along with appropriate space radiation spectra, are input into the NASA program couplet HZETRN/BRYNTRN, and organ doses are calculated. The areal density maps selected tissues and organs of the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared. In addition, the organ doses for the 5th, 50th, and 95th PCTL male and female phantoms are presented and compared to organ doses for CAM and CAF.

  16. Phantom positioning variation in the Gamma Knife® Perfexion dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Costa, Nathalia Almeida; Potiens, Maria da Penha Albuquerque [Instituto de Pesquisas Energeticas e Nucleres (IPEN/CNEN-SP), Sao Paulo, SP (Brazil); Saraiva, Crystian [Hospital do Coracao, Sao Paulo, SP (Brazil)

    2015-07-01

    The use of small volume ionization chamber has become required for the dosimetry of equipment that use small radiation fields. A pinpoint ionization chamber is ideal for the dosimetry of a Gamma Knife® Perfexion (GKP) unit. In this work, this chamber was inserted into the phantom, and measurements were performed with the phantom in different positions, in order to verify if the change in the phantom positioning affects the dosimetry of the GKP. Three different phantom positions were performed. The variation in the result is within the range allowed for the dosimetry of a GKP equipment. (author)

  17. Solid tissue simulating phantoms having absorption at 970 nm for diffuse optics

    Science.gov (United States)

    Kennedy, Gordon T.; Lentsch, Griffin R.; Trieu, Brandon; Ponticorvo, Adrien; Saager, Rolf B.; Durkin, Anthony J.

    2017-07-01

    Tissue simulating phantoms can provide a valuable platform for quantitative evaluation of the performance of diffuse optical devices. While solid phantoms have been developed for applications related to characterizing exogenous fluorescence and intrinsic chromophores such as hemoglobin and melanin, we report the development of a poly(dimethylsiloxane) (PDMS) tissue phantom that mimics the spectral characteristics of tissue water. We have developed these phantoms to mimic different water fractions in tissue, with the purpose of testing new devices within the context of clinical applications such as burn wound triage. Compared to liquid phantoms, cured PDMS phantoms are easier to transport and use and have a longer usable life than gelatin-based phantoms. As silicone is hydrophobic, 9606 dye was used to mimic the optical absorption feature of water in the vicinity of 970 nm. Scattering properties are determined by adding titanium dioxide, which yields a wavelength-dependent scattering coefficient similar to that observed in tissue in the near-infrared. Phantom properties were characterized and validated using the techniques of inverse adding-doubling and spatial frequency domain imaging. Results presented here demonstrate that we can fabricate solid phantoms that can be used to simulate different water fractions.

  18. Floating worlds and their phantoms in the aftermath of social catastrophes.

    Science.gov (United States)

    Kimbles, Samuel

    2017-02-01

    In this paper the author describes certain kinds of images (phantoms) that appear in the aftermath of social catastrophes. These phantoms come with an underlying narrative structure, which the author describes as phantom narratives. Phantom narratives show how the unconscious, working at the group and individual levels, provides political and social contexts within which the individual may find a different kind of containment for these catastrophes. In this way their suffering may be potentially processed psychologically and related to symbolically. © 2017, The Society of Analytical Psychology.

  19. A novel composite material specifically developed for ultrasound bone phantoms: cortical, trabecular and skull.

    Science.gov (United States)

    Wydra, A; Maev, R Gr

    2013-11-21

    In the various stages of developing diagnostic and therapeutic equipment, the use of phantoms can play a very important role in improving the process, help in implementation, testing and calibrations. Phantoms are especially useful in developing new applications and training new doctors in medical schools. However, devices that use different physical factors, such as MRI, Ultrasound, CT Scan, etc will require the phantom to be made of different physical properties. In this paper we introduce the properties of recently designed new materials for developing phantoms for ultrasonic human body investigation, which in today's market make up more than 30% in the world of phantoms. We developed a novel composite material which allows fabrication of various kinds of ultrasound bone phantoms to mimic most of the acoustical properties of human bones. In contrast to the ex vivo tissues, the proposed material can maintain the physical and acoustical properties unchanged for long periods of time; moreover, these properties can be custom designed and created to suit specific needs. As a result, we introduce three examples of ultrasound phantoms that we manufactured in our laboratory: cortical, trabecular and skull bone phantoms. The paper also presents the results of a comparison study between the acoustical and physical properties of actual human bones (reported in the referenced literatures) and the phantoms manufactured by us.

  20. Phantom limb perception interferes with motor imagery after unilateral upper-limb amputation.

    Science.gov (United States)

    Lyu, Yuanyuan; Guo, Xiaoli; Bekrater-Bodmann, Robin; Flor, Herta; Tong, Shanbao

    2016-02-16

    A potential contributor to impaired motor imagery in amputees is an alteration of the body schema as a result of the presence of a phantom limb. However, the nature of the relationship between motor imagery and phantom experiences remains unknown. In this study, the influence of phantom limb perception on motor imagery was investigated using a hand mental rotation task by means of behavioral and electrophysiological measures. Compared with healthy controls, significantly prolonged response time for both the intact and missing hand were observed specifically in amputees who perceived a phantom limb during the task but not in amputees without phantom limb perception. Event-related desynchronization of EEG in the beta band (beta-ERD) in central and parietal areas showed an angular disparity specifically in amputees with phantom limb perception, with its source localized in the right inferior parietal lobule. The response time as well as the beta-ERD values were significantly positively correlated with phantom vividness. Our results suggest that phantom limb perception during the task is an important interferential factor for motor imagery after amputation and the interference might be related to a change of the body representation resulting from an unnatural posture of the phantom limb.

  1. Disappearance of "phantom limb" and amputated arm usage during dreaming in REM sleep behaviour disorder.

    Science.gov (United States)

    Vetrugno, Roberto; Arnulf, Isabelle; Montagna, Pasquale

    2009-01-01

    Limb amputation is followed, in approximately 90% of patients, by "phantom limb" sensations during wakefulness. When amputated patients dream, however, the phantom limb may be present all the time, part of the time, intermittently or not at all. Such dreaming experiences in amputees have usually been obtained only retrospectively in the morning and, moreover, dreaming is normally associated with muscular atonia so the motor counterpart of the phantom limb experience cannot be observed directly. REM sleep behaviour disorder (RBD), in which muscle atonia is absent during REM sleep and patients act out their dreams, allows a more direct analysis of the "phantom limb" phenomena and their modifications during sleep.

  2. Quantitative bone mineral analysis using computed tomography with the new calibration phantom

    Energy Technology Data Exchange (ETDEWEB)

    Kakuta, Shigeru (Saint Marianna Univ. School of Medicine, Kawasaki, Kanagawa (Japan))

    1992-10-01

    There are several problems in quantitative bone mineral analysis using computed tomography. Recently, CaCO[sub 3] phantom (B-MAS) has been widely used to measure the bone mineral content, although B-MAS has two problems. Firstly, the characteristics of X-ray absorption of CaCO[sub 3] are different from those of hydroxyapatite which is the main component of bone tissue. Secondly, in small patients, the phantom does not fit the body well due to its large (300 mm) width. This discrepancy between patient and phantom leads to inexact CT-number measurement of the most lateral chambers on both sides. To solve these problems, a new calibration phantom containing known concentrations of hydroxyapatite (0, 50, 100, 150, 200 mm/cm[sup 3]) as a standard substance was developed, and the width of the phantom was reduced from 300 mm to 200 mm. Clinically, quantitative computed tomography (QCT) of the third lumbar vertebral body was performed with this new phantom in 178 cases and compared with those of the B-MAS phantom. The correlations between the concentration of the standard substance and CT-number were significantly higher in the new phantom than in the B-MAS. Based on these results, we consider the new calibration phantom useful for bone-mineral measurement by QCT. (author).

  3. Liquid tissue surrogates for X-ray and CT phantom studies.

    Science.gov (United States)

    FitzGerald, Paul F; Colborn, Robert E; Edic, Peter M; Lambert, Jack W; Bonitatibus, Peter J; Yeh, Benjamin M

    2017-10-07

    kVp were -104 HU (-113 HU) for adipose #3, -87 HU (-90 HU) for adipose #2, 59 HU (55 HU) for liver tissue, and 33 HU (31 HU) for pancreatic tissue; at 120 kVp, these were -83 HU (-83 HU) for adipose #3, -68 HU (-63 HU) for adipose #2, 55 HU (52 HU) for liver tissue, and 35 HU (33 HU) for pancreatic tissue. Our method for formulating tissue surrogates allowed straightforward production of solutions with CT attenuation that closely matched the target tissues' expected CT attenuation values and trends with kVp. The LTSs' inexpensive and widely available constituent chemicals, combined with their liquid state, should enable rapid production and versatile use among different phantom and experiment types. Further study is warranted, such as the inclusion of contrast agents. These liquid tissue surrogates may potentially accelerate development and testing of advanced CT imaging techniques and technologies. © 2017 American Association of Physicists in Medicine.

  4. Second-Generation Drosophila Chemical Tags: Sensitivity, Versatility, and Speed.

    Science.gov (United States)

    Sutcliffe, Ben; Ng, Julian; Auer, Thomas O; Pasche, Mathias; Benton, Richard; Jefferis, Gregory S X E; Cachero, Sebastian

    2017-04-01

    Labeling and visualizing cells and subcellular structures within thick tissues, whole organs, and even intact animals is key to studying biological processes. This is particularly true for studies of neural circuits where neurons form submicron synapses but have arbors that may span millimeters in length. Traditionally, labeling is achieved by immunofluorescence; however, diffusion of antibody molecules (>100 kDa) is slow and often results in uneven labeling with very poor penetration into the center of thick specimens; these limitations can be partially addressed by extending staining protocols to over a week (Drosophila brain) and months (mice). Recently, we developed an alternative approach using genetically encoded chemical tags CLIP, SNAP, Halo, and TMP for tissue labeling; this resulted in >100-fold increase in labeling speed in both mice and Drosophila, at the expense of a considerable drop in absolute sensitivity when compared to optimized immunofluorescence staining. We now present a second generation of UAS- and LexA-responsive CLIPf, SNAPf, and Halo chemical labeling reagents for flies. These multimerized tags, with translational enhancers, display up to 64-fold increase in sensitivity over first-generation reagents. In addition, we developed a suite of conditional reporters (4xSNAPf tag and CLIPf-SNAPf-Halo2) that are activated by the DNA recombinase Bxb1. Our new reporters can be used with weak and strong GAL4 and LexA drivers and enable stochastic, intersectional, and multicolor Brainbow labeling. These improvements in sensitivity and experimental versatility, while still retaining the substantial speed advantage that is a signature of chemical labeling, should significantly increase the scope of this technology. Copyright © 2017 Sutcliffe et al.

  5. Versatile rogue waves in scalar, vector, and multidimensional nonlinear systems

    Science.gov (United States)

    Chen, Shihua; Baronio, Fabio; Soto-Crespo, Jose M.; Grelu, Philippe; Mihalache, Dumitru

    2017-11-01

    This review is dedicated to recent progress in the active field of rogue waves, with an emphasis on the analytical prediction of versatile rogue wave structures in scalar, vector, and multidimensional integrable nonlinear systems. We first give a brief outline of the historical background of the rogue wave research, including referring to relevant up-to-date experimental results. Then we present an in-depth discussion of the scalar rogue waves within two different integrable frameworks—the infinite nonlinear Schrödinger (NLS) hierarchy and the general cubic-quintic NLS equation, considering both the self-focusing and self-defocusing Kerr nonlinearities. We highlight the concept of chirped Peregrine solitons, the baseband modulation instability as an origin of rogue waves, and the relation between integrable turbulence and rogue waves, each with illuminating examples confirmed by numerical simulations. Later, we recur to the vector rogue waves in diverse coupled multicomponent systems such as the long-wave short-wave equations, the three-wave resonant interaction equations, and the vector NLS equations (alias Manakov system). In addition to their intriguing bright–dark dynamics, a series of other peculiar structures, such as coexisting rogue waves, watch-hand-like rogue waves, complementary rogue waves, and vector dark three sisters, are reviewed. Finally, for practical considerations, we also remark on higher-dimensional rogue waves occurring in three closely-related (2  +  1)D nonlinear systems, namely, the Davey–Stewartson equation, the composite (2  +  1)D NLS equation, and the Kadomtsev–Petviashvili I equation. As an interesting contrast to the peculiar X-shaped light bullets, a concept of rogue wave bullets intended for high-dimensional systems is particularly put forward by combining contexts in nonlinear optics.

  6. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  7. Lithium: a versatile tool for understanding renal physiology

    Science.gov (United States)

    Ecelbarger, Carolyn M.

    2013-01-01

    By virtue of its unique interactions with kidney cells, lithium became an important research tool in renal physiology and pathophysiology. Investigators have uncovered the intricate relationships of lithium with the vasopressin and aldosterone systems, and the membrane channels or transporters regulated by them. While doing so, their work has also led to 1) questioning the role of adenylyl cyclase activity and prostaglandins in lithium-induced suppression of aquaporin-2 gene transcription; 2) unraveling the role of purinergic signaling in lithium-induced polyuria; and 3) highlighting the importance of the epithelial sodium channel (ENaC) in lithium-induced nephrogenic diabetes insipidus (NDI). Lithium-induced remodeling of the collecting duct has the potential to shed new light on collecting duct remodeling in disease conditions, such as diabetes insipidus. The finding that lithium inhibits glycogen synthase kinase-3β (GSK3β) has opened an avenue for studies on the role of GSK3β in urinary concentration, and GSK isoforms in renal development. Finally, proteomic and metabolomic profiling of the kidney and urine in rats treated with lithium is providing insights into how the kidney adapts its metabolism in conditions such as acquired NDI and the multifactorial nature of lithium-induced NDI. This review provides state-of-the-art knowledge of lithium as a versatile tool for understanding the molecular physiology of the kidney, and a comprehensive view of how this tool is challenging some of our long-standing concepts in renal physiology, often with paradigm shifts, and presenting paradoxical situations in renal pathophysiology. In addition, this review points to future directions in research where lithium can lead the renal community. PMID:23408166

  8. Versatile in situ gas analysis apparatus for nanomaterials reactors.

    Science.gov (United States)

    Meysami, Seyyed Shayan; Snoek, Lavina C; Grobert, Nicole

    2014-09-02

    We report a newly developed technique for the in situ real-time gas analysis of reactors commonly used for the production of nanomaterials, by showing case-study results obtained using a dedicated apparatus for measuring the gas composition in reactors operating at high temperature (reactor, while suppressing the thermal decomposition of the analytes. It thus allows a more accurate study of the mechanism of progressive thermocatalytic cracking of precursors compared to previously reported conventional residual gas analyses of the reactor exhaust gas and hence paves the way for the controlled production of novel nanomaterials with tailored properties. Our studies demonstrate that the composition of the precursors dynamically changes as they travel inside of the reactor, causing a nonuniform growth of nanomaterials. Moreover, mapping of the nanomaterials reactor using quantitative gas analysis revealed the actual contribution of thermocatalytic cracking and a quantification of individual precursor fragments. This information is particularly important for quality control of the produced nanomaterials and for the recycling of exhaust residues, ultimately leading toward a more cost-effective continuous production of nanomaterials in large quantities. Our case study of multiwall carbon nanotube synthesis was conducted using the probe in conjunction with chemical vapor deposition (CVD) techniques. Given the similarities of this particular CVD setup to other CVD reactors and high-temperature setups generally used for nanomaterials synthesis, the concept and methodology of in situ gas analysis presented here does also apply to other systems, making it a versatile and widely applicable method across a wide range of materials/manufacturing methods, catalysis, as well as reactor design and engineering.

  9. A versatile miniature bioreactor and its application to bioelectrochemistry studies.

    Science.gov (United States)

    Kloke, A; Rubenwolf, S; Bücking, C; Gescher, J; Kerzenmacher, S; Zengerle, R; von Stetten, F

    2010-08-15

    Often, reproducible investigations on bio-microsystems essentially require a flexible but well-defined experimental setup, which in its features corresponds to a bioreactor. We therefore developed a miniature bioreactor with a volume in the range of a few millilitre that is assembled by alternate stacking of individual polycarbonate elements and silicone gaskets. All the necessary supply pipes are incorporated as bore holes or cavities within the individual elements. Their combination allows for a bioreactor assembly that is easily adaptable in size and functionality to experimental demands. It allows for controlling oxygen transfer as well as the monitoring of dissolved oxygen concentration and pH-value. The system provides access for media exchange or sterile sampling. A mass transfer coefficient for oxygen (k(L)a) of 4.3x10(-3) s(-1) at a flow rate of only 15 ml min(-1) and a mixing time of 1.5s at a flow rate of 11 ml min(-1) were observed for the modular bioreactor. Single reactor chambers can be interconnected via ion-conductive membranes to form a two-chamber test setup for investigations on electrochemical systems such as fuel cells or sensors. The versatile applicability of this modular and flexible bioreactor was demonstrated by recording a growth curve of Escherichia coli (including monitoring of pH and oxygen) saturation, and also as by two bioelectrochemical experiments. In the first electrochemical experiment the use of the bioreactor enabled a direct comparison of electrode materials for a laccase-catalyzed oxygen reduction electrode. In a second experiment, the bioreactor was utilized to characterize the influence of outer membrane cytochromes on the performance of Shewanella oneidensis in a microbial fuel cell. Copyright 2010 Elsevier B.V. All rights reserved.

  10. Phosphatidic acid, a versatile water-stress signal in roots

    Directory of Open Access Journals (Sweden)

    Fionn eMcLoughlin

    2013-12-01

    Full Text Available Adequate water supply is of utmost importance for growth and reproduction of plants. In order to cope with water deprivation, plants have to adapt their development and metabolism to ensure survival. To maximize water use efficiency, plants use a large array of signaling mediators such as hormones, protein kinases and phosphatases, Ca2+, reactive oxygen species and low abundant phospholipids that together form complex signaling cascades. Phosphatidic acid (PA is a signaling lipid that rapidly accumulates in response to a wide array of abiotic stress stimuli. PA formation provides the cell with spatial and transient information about the external environment by acting as a protein-docking site in cellular membranes. PA reportedly binds to a number of proteins that play a role during water limiting conditions, such as drought and salinity and has been shown to play an important role in maintaining root system architecture. Members of two osmotic stress-activated protein kinase families, sucrose non-fermenting 1-related protein kinase 2 (SnRK2 and mitogen activated protein kinases (MAPKs were recently shown bind PA and are also involved in the maintenance of root system architecture and salinity stress tolerance. In addition, PA regulates several proteins involved in abscisic acid (ABA-signaling. PA-dependent recruitment of glyceraldehyde-3-phosphate dehydrogenase (GAPDH under water limiting conditions indicates a role in regulating metabolic processes. Finally, a recent study also shows the PA recruits the clathrin heavy chain and a potassium channel subunit, hinting towards additional roles in cellular trafficking and potassium homeostasis. Taken together, the rapidly increasing number of proteins reported to interact with PA implies a broad role for this versatile signaling phospholipid in mediating salt and water stress responses.

  11. SCIMPI: A versatile seafloor observatory for changing environments

    Science.gov (United States)

    Moran, K.; Lado Insua, T.; Kulin, I.; Farrington, S.; Newman, J.

    2011-12-01

    The Simple Cabled Instrument for Measuring Parameters In-situ (SCIMPI) is a new seafloor observatory instrument. SCIMPI is designed to take subsurface time series measurements of temperature, pressure and resistivity in the sub-seafloor. This instrument has a battery operational life of approximately two years, which can be replaced with a battery pack using a remotely-operated vehicle, and provides high resolution measurements of physical properties in the sediment. With either periodic battery replacement or connection to a fiber-optic cable, SCIMPI is a long-term observatory for understanding sub-seafloor dynamics. The main advantage of this system is the reduced equipment and installation requirements making this tool an affordable and versatile system for scientific research. The pressure and temperature sensors, integrated into the system, have been successfully used in other marine industrial and scientific applications. Its electrical resistivity sensor, casing, and array assembly are uniquely designed and can be adapted for each mission. SCIMPI is currently in its last phase of testing prior to deployment in an Integrated Ocean Drilling Program borehole. This first SCIMPI is designed for a water depth of 1000 m and a sediment depth up to ~300 m below seafloor. But future assemblies can be tailored for deeper conditions and environments. Here we present the SCIMPI design, deployment options, and its scientific potential in a long-term ocean observatory. Science applications include studies of fluid flow, hydrate formation, and seismically induced pore pressure changes. The cost of this instrument will enable these measurements to become more commonplace, thereby improving our temporal and spatial knowledge of sub-seafloor gas, fluid and pore pressure activity. Most notable of the target deployments for SCIMPI are sub-seafloor gas hydrate sites and sites with biogenic methane. Understanding the dynamics of methane's role in the oceans as climate change

  12. In Vivo Optical Imaging for Targeted Drug Kinetics and Localization for Oral Surgery and Super-Resolution, Facilitated by Printed Phantoms

    Science.gov (United States)

    Bentz, Brian Z.

    Many human cancer cell types over-express folate receptors, and this provides an opportunity to develop targeted anti-cancer drugs. For these drugs to be effective, their kinetics must be well understood in vivo and in deep tissue where tumors occur. We demonstrate a method for imaging these parameters by incorporating a kinetic compartment model and fluorescence into optical diffusion tomography (ODT). The kinetics were imaged in a live mouse, and found to be in agreement with previous in vitro studies, demonstrating the validity of the method and its feasibility as an effective tool in preclinical drug development studies. Progress in developing optical imaging for biomedical applications requires customizable and often complex objects known as "phantoms" for testing and evaluation. We present new optical phantoms fabricated using inexpensive 3D printing methods with multiple materials, allowing for the placement of complex inhomogeneities in heterogeneous or anatomically realistic geometries, as opposed to previous phantoms which were limited to simple shapes formed by molds or machining. Furthermore, we show that Mie theory can be used to design the optical properties to match a target tissue. The phantom fabrication methods are versatile, can be applied to optical imaging methods besides diffusive imaging, and can be used in the calibration of live animal imaging data. Applications of diffuse optical imaging in the operating theater have been limited in part due to computational burden. We present an approach for the fast localization of arteries in the roof of the mouth that has the potential to reduce complications. Furthermore, we use the extracted position information to fabricate a custom surgical guide using 3D printing that could protect the arteries during surgery. The resolution of ODT is severely limited by the attenuation of high spatial frequencies. We present a super-resolution method achieved through the point localization of fluorescent

  13. Volumetric Intraoperative Brain Deformation Compensation: Model Development and Phantom Validation

    Science.gov (United States)

    DeLorenzo, Christine; Papademetris, Xenophon; Staib, Lawrence H.; Vives, Kenneth P.; Spencer, Dennis D.; Duncan, James S.

    2012-01-01

    During neurosurgery, nonrigid brain deformation may affect the reliability of tissue localization based on preoperative images. To provide accurate surgical guidance in these cases, preoperative images must be updated to reflect the intraoperative brain. This can be accomplished by warping these preoperative images using a biomechanical model. Due to the possible complexity of this deformation, intraoperative information is often required to guide the model solution. In this paper, a linear elastic model of the brain is developed to infer volumetric brain deformation associated with measured intraoperative cortical surface displacement. The developed model relies on known material properties of brain tissue, and does not require further knowledge about intraoperative conditions. To provide an initial estimation of volumetric model accuracy, as well as determine the model’s sensitivity to the specified material parameters and surface displacements, a realistic brain phantom was developed. Phantom results indicate that the linear elastic model significantly reduced localization error due to brain shift, from >16 mm to under 5 mm, on average. In addition, though in vivo quantitative validation is necessary, preliminary application of this approach to images acquired during neocortical epilepsy cases confirms the feasibility of applying the developed model to in vivo data. PMID:22562728

  14. Cortical stimulation mapping of phantom limb rolandic cortex. Case report.

    Science.gov (United States)

    Ojemann, J G; Silbergeld, D L

    1995-04-01

    Findings of intraoperative rolandic cortex mapping during awake craniotomy for a tumor in a patient with a contralateral upper-extremity amputation are presented. This patient sustained a traumatic amputation at the mid-humerus 24 years previously. Initially he had experienced rare painless phantom limb sensations but none in the past 10 years. Functional mapping during an awake craniotomy was performed to maximize safe tumor resection. Typical temporal and frontal speech areas were identified; motor representation of face and jaw extended more superiorly than sensory representation. Shoulder movements were evoked more laterally than usual at the superior aspect of the craniotomy. A small region of precentral gyrus, between the jaw and shoulder representations, elicited no detectable effect when stimulated. Somatosensory mapping showed a similar topographical distribution of face and mouth cortex; however, posterior and inferior to the shoulder motor cortex, right arm and hand (phantom) sensations were evoked. Evidence suggests that significant motor reorganization occurs following an amputation, with expansion of neighboring homuncular representations without loss of somatosensory representation, despite a long period of time without any sensation referable to the amputated limb. Contrary to models of sensory cortex plasticity, the plasticity of the adult cortex may be system specific, with reorganization present in motor, but not in sensory, cortical systems.

  15. Oil-based gel phantom for ultrasound and optical imaging

    Science.gov (United States)

    Cabrelli, Luciana C.; Pelissari, Pedro I. B. G. B.; Aggarwal, Lucimara P.; Deana, Alessandro M.; Carneiro, Antonio A. O.; Pavan, Theo. Z.

    2015-06-01

    Water-based materials are commonly used in phantoms for ultrasound and optical imaging techniques. However, these materials have disadvantages such as easy degradation and low temporal stability. In this study, we propose an oil-based new tissue mimicking material for ultrasound and optical imaging, with the advantage of presenting low temporal degradation. Styrene-Ethylene/Butylene-Styrene (SEBS) copolymer in mineral oil samples were made varying the SEBS concentration between 5-15%, and low-density polyethylene (LDPE) between 0-9%. Acoustic properties such as speed of sound and attenuation coefficient were obtained by the substitution technique with frequencies ranging from 2.25-10 MHz, and were consistent to that of soft tissue. These properties were controlled varying SEBS and LDPE concentration; speed of sound from 1445-1480 m/s, and attenuation from 0.86-11.31 dB/cm were observed. SEBS gels with 0% of LDPE were optically transparent, presenting low optical absorption and scattering coefficients in the visible region of the spectrum. In order to fully characterize the optical properties of the samples, the reflectances of the surfaces were measured, along with the absorption. Scattering and absorption coefficients ranging from 400 nm to 1200 nm were calculated for each compound. The results showed that the presence of LDPE increased absorption and scattering of the phantoms. The results suggest the copolymer gels are promising for ultrasound and optical imaging, what make them also potentially useful for photoacoustic imaging.

  16. Diffuse optical spectroscopy of melanoma-simulating silicone phantoms

    Science.gov (United States)

    Grant, Alexander M.; Sry, Kelly; Saager, Rolf; Ayers, Frederick; Pfefer, T. Joshua; Kelly, Kristen M.; Tseng, Sheng-Hao; Durkin, Anthony J.

    2009-02-01

    Currently the only method for positively identifying malignant melanoma involves invasive and often undesirable biopsy procedures. Available ex-vivo data indicates increased vascularization in the lower regions of excised melanoma, as compared to dysplastic nevi. The ability to interrogate this region of tissue in-vivo could lead to useful diagnostic information. Using a newly developed fiber based superficial probe in conjunction with a steady-state frequency-domain photon migration (SSFDPM) system, we can probe the upper 1-2 mm of tissue, extracting functional information in the near infrared (650-1000 nm) range. To test the resolution and detection range of the superficial probe in this context, deformable silicone phantoms have been fabricated that simulate normal skin with melanocytic lesions. These phantoms consist of a two-layered matrix with the optical properties of normal light skin, containing several cylindrical inclusions that simulate highly absorbing pigmented lesions such as melanoma. These inclusions are varied in depth, diameter, and optical properties in order to fully test the probe's detection capabilities. It was found that, depending on absorption, we can typically probe to a depth of 1.0-1.5 mm in an inclusion, likely reaching the site of angiogenesis in an early-stage melanoma. Additionally, we can successfully interrogate normal tissue below lesions 1.5mm deep when absorption is about 0.4/mm or less. This data indicates that the superficial probe shows great promise for non-invasive diagnosis of pigmented lesions.

  17. Bulk viscosity, interaction and the viability of phantom solutions

    Energy Technology Data Exchange (ETDEWEB)

    Leyva, Yoelsy; Sepulveda, Mirko [Universidad de Tarapaca, Departamento de Fisica, Facultad de Ciencias, Arica (Chile)

    2017-06-15

    We study the dynamics of a bulk viscosity model in the Eckart approach for a spatially flat Friedmann-Robertson-Walker (FRW) Universe. We have included radiation and dark energy, assumed as perfect fluids, and dark matter treated as an imperfect fluid having bulk viscosity. We also introduce an interaction term between the dark matter and dark energy components. Considering that the bulk viscosity is proportional to the dark matter energy density and imposing a complete cosmological dynamics, we find bounds on the bulk viscosity in order to reproduce a matter-dominated era (MDE). This constraint is independent of the interaction term. Some late time phantom solutions are mathematically possible. However, the constraint imposed by a MDE restricts the interaction parameter, in the phantom solutions, to a region consistent with a null value, eliminating the possibility of late time stable solutions with w < -1. From the different cases that we study, the only possible scenario, with bulk viscosity and interaction term, belongs to the quintessence region. In the latter case, we find bounds on the interaction parameter compatible with latest observational data. (orig.)

  18. Peripheral nervous system origin of phantom limb pain.

    Science.gov (United States)

    Vaso, Apostol; Adahan, Haim-Moshe; Gjika, Artan; Zahaj, Skerdi; Zhurda, Tefik; Vyshka, Gentian; Devor, Marshall

    2014-07-01

    Nearly all amputees continue to feel their missing limb as if it still existed, and many experience chronic phantom limb pain (PLP). What is the origin of these sensations? There is currently a broad consensus among investigators that PLP is a top-down phenomenon, triggered by loss of sensory input and caused by maladaptive cortical plasticity. We tested the alternative hypothesis that PLP is primarily a bottom-up process, due not to the loss of input but rather to exaggerated input, generated ectopically in axotomized primary afferent neurons in the dorsal root ganglia (DRGs) that used to innervate the limb. In 31 amputees, the local anesthetic lidocaine was applied intrathecally and/or to the DRG surface (intraforaminal epidural block). This rapidly and reversibly extinguished PLP and also nonpainful phantom limb sensation (npPLS). Control injections were ineffective. For intraforaminal block, the effect was topographically appropriate. The suppression of PLP and npPLS could also be demonstrated using dilute lidocaine concentrations that are sufficient to suppress DRG ectopia but not to block the propagation of impulses generated further distally in the nerve. PLP is driven primarily by activity generated within the DRG. We recommend the DRG as a target for treatment of PLP and perhaps also other types of regional neuropathic pain. Copyright © 2014 International Association for the Study of Pain. Published by Elsevier B.V. All rights reserved.

  19. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  20. Evaluation of mitral valve replacement anchoring in a phantom

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.

    2012-02-01

    Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.