WorldWideScience

Sample records for ventriculografia radioisotopica gatillada

  1. Left ventricle ejection fraction obtained by radioisotopic angiocardiography. Correlation between the values of the conventional ventriclegraphy. Fracao de ejecao do ventriculo esquerdo obtida por angiocardiografia radioisotopica. Correlacao com os valores fornecidos pela ventriculografia convencional

    Energy Technology Data Exchange (ETDEWEB)

    Ascer, E; Pimentel Filho, W A; Martins, L R.F.; Marioni Filho, H; Queiroga Filho, A F; Alonso, G; Germek, O A; Thom, A F; Souza, J E.M.R. [Instituto Dante Pazzanese de Cardiologia, Sao Paulo, SP (Brazil)

    1983-02-01

    Forty-two patients with clinical signs of coronary insuficiency underwent cineangiographic and radioisotopic examinations with the purpose of analysing the correlation between the values of left ventricle ejection fraction (LVEF) obtained by both methods. The values of EF obtained by the hemodynamic method (HEMO) ranged from 0.14 to 0.85 (x-bar = 0.566) and by radioisotopic method (RM) from 0.22 to 0.89 (x-bar = 0.573). The Student T test did not demonstrate statistically significant differences between the two methods (mean of differences = 0.007; t = 0.38 and p {ge} 0.353). A regression equation was obtained in order to estimate the EF by HEMO deriving from results obtained by RM (y = 0.11 + 0.80x) and to estimate the EF through RN from the results obtained by HEMO (x = 0.08 + 0.86y), where y = hemodynamic method and x = radioisotopic method. The authors conclude that the calculation of the EF by the methods used showed a good correlation and that this fact is evidenced by the elevated Pearson's correlation coefficient (r = 0.833). (author).

  2. Tomografia computadorizada em pacientes portadores de neurocisticercose com hipertensão intracraniana por hidrocefalia obstrutiva: comparação com ventriculografia com Dimer-X

    Directory of Open Access Journals (Sweden)

    Benedicto Oscar Colli

    1984-06-01

    Full Text Available Estudo das alterações observadas nas tomografias computadorizadas (TCs de 16 casos de neurocisticercose, com hipertensão intracraniana por hidrocefalia. Todos os casos foram submetidos a radiografias simples do crânio e 12, à ventriculografia com Dimer-X. Nas radiografias simples foram observados sinais de hipertensão intracraniana em 7, calcificações em um, e d foram normais. A TC mostrou parênquima cerebral normal em 9 casos e nos 7 restantes áreas hipodensas arredondadas de tamanho variado, com ou sem retenção de contraste na periferia, e/ou calcificações esparsas no parenquima. Hidrocefalia foi a única alteração observada no sistema ventricular nos casos em que o exame foi realizado previamente à derivação do LCR. As ventriculografias foram analisadas em trabalho anterior e permitiram localizar e determinar as características da obstrução e a presença de massas ocupando espaço dentro dos ventrículos. A comparação das ventriculografias e TCs realizadas na mesma época evidenciou que a primeira fornece melhores informações sobre o sistema ventricular mas, por outro lado, a tomografia fornece informações adicionais sobre o parênquima cerebral. A TC e a ventriculografia são exames que se completam na avaliação e no diagnóstico destes pacientes.

  3. Theory of Radioisotope Scanning; Theorie de l'Exploration au Moyen d'un Radioisotope; Matematicheskaya osnova radioizotopnogo skennirovaniya; Teoria de la Exploracion Radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Brownell, G. L. [Massachusetts General Hospital, Boston, MA (United States)

    1964-10-15

    'auteur etudie les relations qui existent entre la resolution optimum, d'une part, la concentration du radioisotope et sa repartition, d'autre part. L'exploration au moyen d'un radioisotope peut etre consideree comme un moyen d'extraire et de presenter des informations. Les informations primaires se trouvent dans la repartition initiale du radioisotope. Le collimateur et l e detecteur constituent le mecanisme de transfert de l'information et le scintigramme final presente les informations obtenues. Comme dans toutes les techniques de ce genre, le scintigramme final ne contient qu'une faible partie des informations. On peut montrer que, dans le cas d'ensembles comportant un collimateur a focalisation ou une camera a scintillation, le nombre de coups par surface de resolution varie comme la quatrieme puissance du diametre de resolution. Pour certaines repartitions du radioisotope, il est possible de deduire analytiquement une valeur optimum du diametre de resolution. Toutefois, avec la plupart des ensembles, cette valeur optimum doit etre determinee par approximations successives. Dans ce cas, les problemes qui se posent sont analogues a ceux que pose la determination d'une repartition dans d'autres domaines. L'auteur a etabli un programme pour calculatrice, qui doit permettre de determiner plus facilement la resolution optimum pour differents types de repartitions. La calculatrice utilisee est le seul appareil de ce genre qui comporte une memoire intermediaire a disques et une tete de lecture a tube a rayons cathodiques. Les resultats pourront etre appliques a l'etude d'un grand nombre d'ensembles de scintigraphic. (author) [Spanish] Todas las tecnicas de exploracion radioisotopica con colimadores enfocados, detectores de positrones o camaras de centelleo de los modelos m as recientes plantean ciertos problemas basicos. Su exito depende en gran medida de la eleccion acertada de varias parametros del dispositivo de colimacion, el m as importante de los cuales es el poder de

  4. A Theory of Radioisotope Scanning Systems; Une Theorie des Systemes de Scintigraphoe au Moyen des Radioisotopes; Teoriya sistem radioizotopnogo skennirovaniya; Teoria de los Sistemas de Exploracion Radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Beck, R. N. [Argonne Cancer Research Hospital, University of Chicago, Chicago, IL (United States)

    1964-10-15

    parois du collimateur (EP); c) par dispersion dans la source ou l e collimateur (ES). Dans le cas des collimateurs a canaux multiples, les equations exactes pour ces composantes sont tres complexes. Des valeurs approchees, d'interet pratique, sont donnees pour E, P et S; l'auteur discute les conditions dans lesquelles on peut les utiliser. La resolution du collimateur, definie par une fraction de la largeur de la courbe de reponse pour une source ponctuelle, ne suffit pas pour prevoir la reponse pour une source en volume. Une situation analogue se presente en optique ou ' l'on comprend de mieux en mieux que les avantages du pouvoir de resolution comme critere de qualite sont en grande partie illusoires'. S'inspirant de cette consideration, l'auteur introduit le concept dela 'reponseauneondesinusoiedale' pour definir la resolution des detecteurs a scintillation collimates pour les sources non ponctuelles. (author) [Spanish] El principal objetivo de una teoria general de los sistemas de exploracion radioisotopica es predecir y evaluar el rendimiento de sistemas hipoteticos concebidos para fines bien determinados, por ejemplo, para la deteccion de tumores cerebrales. Dicha teori'a deberia dar respuestas cuantitativas a preguntas taies como la siguiente: 'Para la deteccion de tumores cerebrales de un cierto tamaño, profundidad, etc., es necesario utilizar un aparato de exploracion concebido para el {sup 131}I o para el {sup 203}Hg?'. El autor trata de coordinar los diversos elementos de uiia teoria de esa clase y de establecer ecuaciones que expresen las relaciones entre los parametras biologicos y fisicos que deben tenerse en cuenta: tamaflo y profundidad del tumor, indice de captacion, sensibilidad del colimador, poder de resolucion, distancia focal, superficie del centelleograma, tiempo de exploracion, exactitud de los resultados, etc. El elemento esencial de esta teoria es un criterio o indice de calidad que se pueda calculai para cualquier sistema y sirva para comparer

  5. Theory of Scanning and Imaging of Radioisotope Distributions; Theorie de la Scintigraphoe a Balayage ou Fixe; Teoriya skennirovaniya i izobrazhenie raspredeleniya radioizotopov; Teoria de la Exploracion y de la Obtencion de Imagenes de Distribuciones Radioisotopicas

    Energy Technology Data Exchange (ETDEWEB)

    Cassen, B. [Department of Biophysics and Nuclear Medicine, University of California, Los Angeles, CA (United States)

    1964-10-15

    point et ameliorations et d'essais. (author) [Spanish] En un articulo ya publicado el autor expuso una teoria fundamental simplificada de las caracteristicas cuantitativas de funcionamiento de diversos sistemas de exploracion y obtencion de imagenes radioisotopicas. De ella hadeducidoun 'indice de calidad' que varia segun las caracteristicas del instrumente y segun el metodo empleado. Los factores que intervienen en dicho indice de calidad son: la sensibilidad del detector para el angulo solido subtendido por un elemento de resolucion, el numero de elementos de resolucion 'vistos' simultaneamente, el numero de elementos de resolucion en el conjunto del campo que se explora o cuya imagen se obtiene, la concentracion del radioisotopo, el tiempo total necesario para obtener una imagen y la intensidad de la actividad de fondo. En la actual presentacion, la teoria fundamental ha sido perfeccionada teniendo encuentaotros factores:el poder de resolucion en funcion de la 'profundidad focal', la velocidad de la exploracion o el tiempo de exposicion, las posibilidades de un poder de resolucion modificable o automa'ticamente variable, la resolubilidad relativa, losnodulos 'frios' y 'calientes', ladimension del campo y el empleo de radioisotopos y de tipos de detectores especiales. A continuacion, el autor expone la manera de tratar les datos obtenidos con las diferentes tecnicas de centelleografia. Analiza las ventajas relativas de los eliminadores de la actividad de fondo y de los metodos de aumentar el contraste, taies como la fotoexploracion, y la centelleograffa policroma. Examina las ventajas y los inconvenientes de registrar en cinta los datos originales y de hacer pasar dicha cinta pot circuitos electronicos que aumenten el contraste o eliminen el fondo. El autor da algunos valores del indice de calidad determinadoe experimentalmente par un aparato comercial de exploracion y para algunos aparatos nuevos, especialmente para uno muy perfeccionadobrevemente descrito en el

  6. Sincronia ventricular em portadores de miocardiopatia dilatada e indivíduos normais: avaliação através da ventriculografia radioisotópica Ventricular synchrony in patients with dilated cardiomyopathy and normal individuals: assessment by radionuclide ventriculography

    Directory of Open Access Journals (Sweden)

    Simone Cristina S. Brandão

    2007-05-01

    Full Text Available OBJETIVO: Estabelecer parâmetros de sincronia intra- e interventricular em indivíduos normais e compará-los aos de pacientes com miocardiopatia dilatada com e sem distúrbios de condução ao eletrocardiograma (ECG. MÉTODOS: Três grupos de pacientes foram incluídos no estudo: 18 indivíduos (G1 sem cardiopatia e com ECG normal (52+/-12 anos, 29% masculinos; 50 portadores de miocardiopatia dilatada e disfunção ventricular esquerda grave, sendo 20 pacientes (G2 com QRS 120 ms (57+/-12 anos, 60% masculinos. Todos foram submetidos à ventriculografia radioisotópica (VR. Para avaliar dissincronia intraventricular esquerda foi estudada a largura do histograma de fase e para avaliar dissincronia interventricular foi medida a diferença da média do ângulo de fase entre o ventrículo direito e o esquerdo (DifDE. RESULTADOS: As frações de ejeção do ventrículo esquerdo (FEVEs foram: 62±6% (G1, 27±6% (G2 e 22±7% (G3 e do VD foram: 46 ± 4% (G1, 38±9%(G2 e 37±9% (G3. A avaliação da largura do histograma de fase foi de: 89±18 ms (G1, 203±54 ms (G2 e 312±130 ms (G3, pOBJECTIVE: To establish the parameters of intra- and interventricular synchrony in normal individuals and to compare them with patients with dilated cardiomyopathy with and without conduction disorders shown in the electrocardiogram (ECG examination. METHODS: Three groups of patients were included in this study: 18 individuals (G1 with no cardiomyopathy and with a normal ECG (52±12 years, 29% male; 50 patients with dilated cardiomyopathy and severe left ventricular dysfunction, with 20 patients (G2 presenting QRS 120ms (57±12 years, 60% male. All patients underwent RV. Evaluation of left intraventricular dyssynchrony was carried out with the measurement of the phase histogram width and interventricular dyssynchrony was evaluated by the difference of the mean phase angle between the right and left ventricles (RLDif. RESULTS: Left ventricle ejection fractions (LVEFs were

  7. Diagnosis of deep venous thrombosis by radioisotopic phlebography; Valor da flebografia radioisotopica no diagnostico da trombose venosa profunda

    Energy Technology Data Exchange (ETDEWEB)

    Araujo, Antonio Luiz de [Universidade do Rio de Janeiro (UNIRIO), RJ (Brazil)

    1993-10-01

    The author studied 20 patients with deep venous thrombosis of members (one of them attacked on both arms), from various etiologies, by mean radioisotopic phlebography, in the Vascular Diseases, Radiology and Nuclear Medicine Services of Army Central Hospital (Rio de Janeiro, Brazil) from january 1988 to june 1990. The years old was 18 to 72. The cause most frequency of deep venous thrombosis was idiopathic (seven cases 33.3%). The presence of clot by radionuclide marker in all cases, 16 observations (76.2%) in the lower members and five in the upper extremities (23.9%); 17 cases (85%) also were a conventional venography and his images were confirmed. The diagnostic of deep venous thrombosis from {sup 99m} T{sub c}MAA (macro aggregate of albumin tagged with technetium) should always de complemented by pulmonary mapping, tracking possible silent emboli. Permit as well repetitions evolutionary until daily and using in patients with history of allergy to radiologic contrast because has not complication. (author)

  8. LA EXTENSION DE RAMAS COLATERALES LUEGO DE UNA LESION A LA MEDULA ESPINAL ES GATILLADA POR LA DEGENERACION AXONAL Y DEPENDE DE LA EXPRESION DEL RECEPTOR DE NEUROTROFINAS P75

    OpenAIRE

    COLLYER SAAVEDRA, EILEEN TEHANI; COLLYER SAAVEDRA, EILEEN TEHANI

    2013-01-01

    Las lesiones a la médula espinal (LME) presentan un pronóstico de recuperación prácticamente nulo debido a la baja capacidad regenerativa que tiene el sistema nervioso central (SNC) de los mamíferos. Este hecho estaría determinado por factores restrictivos microambientales que impiden la regeneración y no por una incapacidad intrínseca regenerativa de las neuronas del SNC. A pesar de que los axones del SNC que han sido dañados no son capaces de regenerar, luego de una LME parcial se observ...

  9. Productivity of a nuclear chemical reactor with gamma radioisotopic sources; Rendimiento de un reactor quimico-nuclear con fuentes radioisotopicas gamma

    Energy Technology Data Exchange (ETDEWEB)

    Anguis T, C

    1975-07-01

    According to an established mathematical model of successive Compton interaction processes the made calculations for major distances are extended checking the acceptability of the spheric geometry model for the experimental data for radioisotopic sources of Co-60 and Cs-137. Parameters such as the increasing factor and the absorbed dose served as comparative base. calculations for the case of a punctual source succession inside a determined volume cylinder are made to obtain the total dose, the deposited energy by each photons energetic group and the total absorbed energy inside the reactor. Varying adequately the height/radius relation for different cylinders, the distinct energy depositions are compared in each one of them once a time standardized toward a standard value of energy emitted by the reactor volume. A relation between the quantity of deposited energy in each point of the reactor and the conversion values of chemical species is established. They are induced by electromagnetic radiation and that are reported as ''G'' in the scientific literature (number of molecules formed or disappeared by each 100 e.v. of energy). Once obtained the molecular performance inside the reactor for each type of geometry, it is optimized the height/radius relation according to the maximum production of molecules by unity of time. It is completed a bibliographical review of ''G'' values reported by different types of aqueous solutions with the purpose to determine the maximum performance of molecular hydrogen as a function of pH of the solution and of the used type of solute among other factors. Calculations for the ethyl bromide production as an example of one of the industrial processes which actually work using the gamma radiation as reactions inductor are realized. (Author)

  10. Productivity of a nuclear chemical reactor with gamma radioisotopic sources; Rendimiento de un reactor quimico-nuclear con fuentes radioisotopicas gamma

    Energy Technology Data Exchange (ETDEWEB)

    Anguis T, C

    1975-07-01

    According to an established mathematical model of successive Compton interaction processes the made calculations for major distances are extended checking the acceptability of the spheric geometry model for the experimental data for radioisotopic sources of Co-60 and Cs-137. Parameters such as the increasing factor and the absorbed dose served as comparative base. calculations for the case of a punctual source succession inside a determined volume cylinder are made to obtain the total dose, the deposited energy by each photons energetic group and the total absorbed energy inside the reactor. Varying adequately the height/radius relation for different cylinders, the distinct energy depositions are compared in each one of them once a time standardized toward a standard value of energy emitted by the reactor volume. A relation between the quantity of deposited energy in each point of the reactor and the conversion values of chemical species is established. They are induced by electromagnetic radiation and that are reported as ''G'' in the scientific literature (number of molecules formed or disappeared by each 100 e.v. of energy). Once obtained the molecular performance inside the reactor for each type of geometry, it is optimized the height/radius relation according to the maximum production of molecules by unity of time. It is completed a bibliographical review of ''G'' values reported by different types of aqueous solutions with the purpose to determine the maximum performance of molecular hydrogen as a function of pH of the solution and of the used type of solute among other factors. Calculations for the ethyl bromide production as an example of one of the industrial processes which actually work using the gamma radiation as reactions inductor are realized. (Author)

  11. Construction of an alternative system for the determination of sensitiveness of neutron radioisotopic primary source standardization system; Construcao de um sistema alternativo para a determinacao da sensibilidade do sistema padronizacao primaria de fontes radioisotopicas de neutrons

    Energy Technology Data Exchange (ETDEWEB)

    Leite, Sandro Passos; Silva, Ademir Xavier da [Coordenacao dos Programas de Pos-Graduacao de Engenharia (PEN/COPPE/UFRJ), RJ (Brazil). Programa de Energia Nuclear; Pereira, Walsan Wagner; Fonseca, Evaldo S. da; Patrao, Karla C. de Souza [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI); Castro, Leonardo Curvello de [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Programa de Pos-Graduacao; Bittencourt, Guilherme Rodrigues [Comissao Nacional de Energia Nuclear (CNEN), Rio de Janeiro, RJ (Brazil). PIBIC

    2009-07-01

    This work studied, through the Monte Carlo modelling, a irradiation system for the aqueous solution MnSO{sub 4} to be used in the proceeding of determination of counting efficiency of the manganese sulfate bath

  12. Some dispersive X-ray fluorescence applications in energies with radioisotopic excitation source; Algunas aplicaciones de la fluorescencia de rayos X dispersiva en energias con fuente de excitacion radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Adelfang, P; Vazquez, C

    1991-12-31

    The aim of this work is based on the use of interelemental correction coefficients which are calculated through fundamental parameters. To this purpose, it is necessary to know about the physical constants for each element including the absorption coefficient values and fluorescence yield, the incidence radiation energy, geometric and instrumental parameters. Besides, a special application of the program for the determination of a Nd-La mixed crystal formula is included. (Author). [Espanol] La propuesta de este trabajo se basa en el empleo de coeficientes de correccion interelementales que son calculados a traves de los parametros fundamentales. Para ello se necesitan conocer las constantes fisicas para cada elemento que incluyen los valores de los coeficientes de absorcion y rendimiento de fluorescencia, la energia de la radiacion de incidencia y parametros instrumentales y geometricos. Se incluye ademas una aplicacion especial del programa para la determinacion de la formula de un cristal mixto de Nd y La. (Autor).

  13. Diagnosis of Massive Pulmonary Embolism in Man by Radioisotope Scanning; Diagnostic par Scintigraphy de l'Embolie Pulmonaire Massive chez l'Homme; Diagnostika massivnoj legochnoj ehmbolii u cheloveka s pomoshch'yu radioizotopnogo skennirovaniya; Diagnostico de la Embolia Pulmonar Masiva en el Hombre por Exploracion Radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Jr., H. N.; Sabiston, Jr., D. C.; Iio, M.; Langan, J. K. [Departments of Medicine, Surgery and Radiology, Johns Hopkins University School of Medicine, Baltimore, MD (United States)

    1964-10-15

    Macroaggregated human-serum albumin particles labelled with either I{sup 131} or chromium-51 have been utilized to determine regional blood flow to the lungs in dogs and man. Following intravenous injection, the particles accumulated in the lung, permitting clear delineation of the lung fields by scintillation scanning. In patients with lung abscess, pneumonia, atelectasis, tumours and thromboembolic disease of the lung, there was a decreased accumulation of the radioactivity in the regions of the lungs involved. The technique was found to be clinically useful in the diagnosis of massive pulmonary emboli in man and in the demonstration of vascular occlusion in certain patients with cor pulmonale. Studies in dogs made possible the determination of the rate at which revascularization occurred following experimental pulmonary emboli. Scintillation scanning was carried out at various times after the removal of the experimental emboli. The circulation was restored through the lungs within a period of several weeks after the removal of chronic pulmonary emboli in dogs. Although aggregated human-serum albumin retained its antigenicity in rabbits, guinea pigs and dogs, extensive studies failed to reveal any antigenicity of the particles to man. Because of the rapid metabolism of the macroaggregated albumin particles, the radiation to the patient was well within permissible levels. The use of albumin of high specific activity permitted injections of small chemical quantities; consequently no cardiovascular effects, such as increases in pulmonary artery pressure, changes in electrocardiogram or respiratory rate, were noted. (author) [French] Pour determiner chez le chien et chez l'homme le flux sanguin vers les poumons, on a utilise des macroparticules d'albumine de serum humain marquee avec {sup 131}I ou {sup 51}Cr. A la suite d'une injection intraveineuse, les particules s'accumulaient dans les poumons, permettant ainsi de delimiter nettement les regions pulmonaires par scintigraphie. Chez les sujets atteints d'abces pulmonaires, de pneumonie, d'atelectasie, de tumeurs ou dethrombo- embolie des poumons, on observait une accumulation moins intense de la radioactivite dans les regions pulmonaires affectees. Du point de vue clinique, cette methode s'est revelee utile pour le diagnostic des embolies pulmonaires massives chez l'homme et pour la mise en evidence d'une occlusion vasculaire chez certains sujets atteints de coeur pulmonaire. Les etudes sur des chiens ont permis de determiner le rythme auquel une vascularisation nouvelle se produisait a la suite d'embolies pulmonaires induites. On a fait des scintigraphies a diverses reprises apres embolectomie. Chez les chiens, la circulation dans les poumons etait retablie dans les quelques semaines qui suivaient l'embolectomie. Si les macroparticules d'albumine de serum humain gardaient leur caractere antigene chez les lapins, les cobayes et les chiens, des etudes tres poussees n'ont pu deceler un tel caractere chez l'homme. Par suite du metabolisme rapide des macroparticules d'albumine, la dose de radioactivite recue par les sujets restait bien en deca des niveaux admissibles. L'emploi d'albumine a forte activite specifique permettait de faire des injections de petites quantites de produit chimique; de ce fait, on n'a pas releve d'effets cardio-vasculaires, tels que des augmentations de la tension dans l'artere pulmonaire, des modifications de l'electro-cardiogramme ou du rythme respiratoire, etc. (author) [Spanish] Los autores utilizaron macroagregados de particulas de seroalbumina humana marcada con {sup 131}I o con {sup 51}Cr para determinar el caudal sanguineo regional que afluye a los pulmones en el perro y en el hombre. Inyectadas por via intravenosa, las particulas se acumulan en el pulmon y permiten delinear claramente los campos pulmonares por exploracion centelleografica. En pacientes con absceso del pulmon, neumonia, atelectasia, tumores y tromboembolias pulmonares, se observo una acumulacion disminuida de radiactividad en las regiones afectadas. Se comprobo la utilidad clinica de esta tecnica para diagnosticar embolias pulmonares masivas en el hombre y para descubrir oclusiones vasculares en ciertos pacientes afectados de cor pulmonale. Los estudios en perros permitieron determinar la rapidez con que progresa la revascularizacion despues de una embolia pulmonar experimental. Se efectuaron varias exploraciones centelleograficas una vez retirados los embolos experimentales. La circulacion se restablecio en todo el pulmon algunas semanas despues de haber eliminado los embolos pulmonares cronicos en los perros. Los agregados de seroalbumina humana han conservado su poder antigenico en los conejos, los cobayos y los perros, pero los estudios realizados no han permitido comprobar que las particulas tengan poder antigenico alguno en el hombre. Gracias al rapido metabolismo de los macroagregados, la dosis de radiacion recibida por el paciente se mantiene bastante inferior a los valores admisibles. El empleo de albuminas de elevada actividad especifica permite limitar considerablemente las cantidades inyectadas; no se observan, por lo tanto, efectos cardiovasculares tales como aumentos de presion en la arteria pulmonar, ni alteraciones del electrocardiograma o del ritmo respiratorio. (author) [Russian] Krupnye chasticy al'bumina syvorotki cheloveka, mechennye jodom-131 ili hromom-51, ispol'zovalis' dlja opredelenija regional'nogo toka krovi v legkih u sobak i cheloveka. Posle vnutrivennogo vvedenija chasticy, nakaplivajushhiesja v legkih, dajut chetkoe izobrazhenie konturov legkih pri scintilljacionnom skenniro- vanii. U pacientov s legochnymi abscessami, pnevmoniej, atelektazom, rakom legkih i trombojembolicheskoj bolezn'ju legkih nabljudalos' ponizhenie nakoplenija radioaktivnosti v porazhennyh uchastkah. Byl najden metod, kotoryj budet prigoden v klinike dlja diagnostiki massivnoj legochnoj jembolii u cheloveka i demonstracii zakuporki sosudov u nekotoryh pacientov s ''cor pulmonale''. Issledovanija na sobakah sdelali vozmozhnym opredelenie skorosti revaskuljarizacii posle jeksperimental'noj legochnoj jembolii. Scintilljacionnoe skennirovanie provodilos' v razlichnye periody vremeni posle udalenija jeksperimental'nogo jembola. Cirkuljacija krovi v legkih u sobak vosstanavlivalas' v techenie neskol'kih nedel' posle udalenija hronicheskogo legochnogo jembola. Hotja krupnye chasticy al'bumina syvorotki cheloveka sohranjali svoi antigennye svojstva dlja krolikov, morskih svinok i sobak, shirokie issledovanija ne priveli k obnaruzheniju kakih-libo antigennyh svojstv jetih chastic dlja cheloveka. Vvidu bystrogo metabolizma krupnyh chastic al'bumina doza obluchenija pacienta nahodilas' v predelah dopustimyh doz. Ispol'zovanie al'bumina s vysokoj udel'noj aktivnost'ju pozvoljalo vvodit' nebol'shie himicheskie kolichestva; vposledstvii ne otmecheno kakih-libo izmenenij so storony serdechno-sosudistoj sistemy, kak povyshenija davlenija v legochnoj arterii, izmenenija jelektrokardiogrammy ili chastoty dyhanija.

  14. In vivo evaluation of biosensors volumetric bio-distribution for measurement of metabolic activity by X-ray correlation, fluorescence, Cerenkov image and radioisotope; Evaluacion in vivo de la biodistribucion volumetrica de biosensores para medicion de la actividad metabolica por correlacion de rayos X, fluorescencia, imagen Cerenkov y radioisotopica

    Energy Technology Data Exchange (ETDEWEB)

    Ramirez N, G. J.

    2016-07-01

    The aim of this study was to characterize the in vivo volumetric distribution of three folate based biosensors by different imaging modalities (X-ray, fluorescence, Cerenkov luminescence and radioisotopic imaging) through the development of a tri dimensional (3D) image reconstruction algorithm. The preclinical and multimodal Xtreme imaging system, with a Multimodal Animal Rotation System (Mars), was used to acquire bidimensional (2D) images, which were processed to obtain the 3D reconstruction. Images of mice at different times (biosensor distribution) were simultaneously obtained from the four imaging modalities. The filtered backprojection and inverse Radon transformation were used as main image-processing techniques. In the first instance, the algorithm developed in Mat lab was able to reconstruct in the 3D form the skeleton of the mice under study. Subsequently, the algorithm was able to get the volumetric profiles of {sup 99m}Tc-Folate-Bombesin (radioisotopic image), {sup 177}Lu-Folate-Bombesin (Cerenkov image), and FolateRSense 680 (fluorescence image) in the tumors and kidneys of the mice. No significant differences were detected between the volumetric quantifications using the standard measurement techniques and the quantifications obtained with the proposal made in this study, nor between the volumetric uptakes in the structures of interest. With the structures reconstructed in the 3D form, the fusion of anatomical (as the skeleton) and functional structures derived from the images of the biosensors uptake was achieved The imaging 3D reconstruction algorithm can be easily extrapolated to different 2D acquisition-type images. This characteristic flexibility of the algorithm developed in this study is an advantage in comparison to similar reconstruction methods. (Author)

  15. Evolución de los derechos civiles de la mujer en la legislación chilena (1855-2015)

    OpenAIRE

    Lepin Molina, Cristian

    2016-01-01

    En el presente artículo, se revisa críticamente la evolución de los derechos de la mujer en el Derecho chileno, desde la dictación de su Código Civil (1855), distinguiéndose entre la situación de la mujer soltera frente a la de la mujer casada. El autor reconoce dos grandes etapas de esta evolución, una de ampliación de derechos (1925-1989), gatillada por distintas transformaciones sociales, como la incorporación de la mujer al trabajo, y otra igualatoria de derechos (1989-2013), ...

  16. Tratamento cirúrgico da comunicação interventricular e rotura da parede livre do ventrículo esquerdo após infarto agudo do miocárdio e da disjunção atrioventricular após troca da valva mitral, empregando o dispositivo de isolamento ventricular (DIV:: estudo experimental

    Directory of Open Access Journals (Sweden)

    BERNARDES Rodrigo de Castro

    1997-01-01

    Full Text Available A rotura de parede livre do ventrículo esquerdo (VE e a comunicação interventricular (CIV por rotura de septo são dois eventos catastróficos que podem complicar a evolução do infarto agudo do miocárdio (IAM. A oportunidade do tratamento cirúrgico, o acesso à CIV e a técnica cirúrgica ideal para o tratamento desta complicação são muito discutidos na literatura (1-5. Os resultados, porém, são quase unânimes: alta taxa de mortalidade. A rotura da parede posterior do ventrículo esquerdo pós troca da valva mitral (disjunção atrioventricular não é uma complicação rara, sendo quase sempre fatal (6, 7. O objetivo de nosso trabalho é discutir a alternativa de tratamento cirúrgico destas graves lesões, sem o manuseio direto do músculo cardíaco friável, necrozado. Desenvolvemos e testamos em animais (carneiros o dispositivo de isolamento ventricular (DIV. No período de 12/7/95 a 10/1/96, operamos 12 carneiros adultos para o implante do DIV. No primeiro período de aprendizado da técnica de implante e de desenvolvimento da prótese, operamos 7 animais, sem sucesso. No segundo período operamos 5 animais, já com o DIV completamente desenvolvido e com a técnica cirúrgica já padronizada; obtivemos sucesso com todos os animais, sobrevivendo com bom débito cardíaco, constatado ao ecocardiograma e à ventriculografia. Após 20 dias de sobrevida, os animais foram submetidos a ventriculografia e ecocardiografia. Observamos o completo isolamento da cavidade ventricular com o emprego do DIV, obtendo o tratamento provisório destas graves lesões.

  17. Cardiomiopatia de takotsubo como causa de disfunção ventricular transitória Takotsubo cardiomyopathy causing transitory ventricular dysfunction

    Directory of Open Access Journals (Sweden)

    Angele A. Alves

    2008-03-01

    Full Text Available Relato do caso de mulher de 74 anos, com hipertensão arterial sistêmica e insuficiência vascular periférica, que apresentou sintomas de síndrome coronariana aguda. A angiografia coronariana demonstrou artérias sem obstruções significativas. A ventriculografia e a ecocardiografia demonstraram acinesia dos segmentos médios e apicais, e hipercinesia dos segmentos basais do ventrículo esquerdo. A paciente evoluiu com recuperação completa da função global e motilidade segmentar em ecocardiografia realizada duas semanas após o início dos sintomas. Esse padrão incomum e reversível de disfunção sistólica e comprometimento segmentar dando ao ventrículo esquerdo forma semelhante a um takotsubo é hoje conhecido como cardiomiopatia do estresse.This is the report of a 74-year-old female patient with a history of systemic hypertension and peripheral vascular disease who presented acute coronary syndrome symptoms. Coronary angiography showed coronary arteries with no significant obstructions. Ventriculography and echocardiography showed akinesia in mid and apical segments; and hyperkinesia of left ventricle basal segments. Two weeks after the onset of symptoms, a new echocardiogram demonstrated normal global and regional systolic function. The uncommon, reversible pattern for systolic dysfunction and segmental compromising that gives left ventricle a takostubo-like shape is known today as stress cardiomyopathy.

  18. APLICACIONES CLÍNICAS DE LAS TÉCNICAS NUCLEARES EN EL ESTUDIO DEL SINCRONISMO VENTRICULAR / Clinical applications of nuclear techniques in the study of ventricular synchronism

    Directory of Open Access Journals (Sweden)

    Amalia Peix González

    2012-07-01

    Full Text Available ResumenTécnicas incruentas como la ecocardiografía, la resonancia magnética nuclear y los estudios de Medicina Nuclear (ventriculografía radioisotópica y gammagrafía de perfusión miocárdica con tomografía de emisión de fotón único, proporcionan información indirecta sobre el sincronismo ventricular cuando se utilizan parámetros de contractilidad mecánica. El análisis de fase de Fourier es un instrumento útil para el empleo de técnicas nucleares con este propósito y se ha aplicado, tanto en la ventriculografía radioisotópica como en la gammagrafía de perfusión. En este trabajo se presenta una revisión en el tiempo de los fundamentos y aplicaciones clínicas de las técnicas nucleares en el estudio del sincronismo ventricular. En la actualidad es la gammagrafía SPECT-gatillada, dentro de las técnicas nucleares, la más utilizada, por la posibilidad que ofrece de evaluar perfusión, función y sincronismo intraventricular en el mismo examen. / AbstractNoninvasive techniques such as echocardiography, nuclear magnetic resonance imaging and nuclear medicine studies (radionuclide ventriculography and myocardial perfusion scintigraphy with single photon emission tomography, provide indirect information about ventricular synchronism when parameters of mechanical contractility are used. The Fourier phase analysis is a useful tool for the use of nuclear techniques for this purpose, and has been applied in both radionuclide ventriculography and perfusion scintigraphy. A review in time of the basics and clinical applications of nuclear techniques in the study of ventricular synchronism is presented in this article. Nowadays, the gated-SPECT scintigraphy is the most common among nuclear techniques because it allows assessing perfusion, function, and intraventricular synchronism in the same test.

  19. Pseudo-aneurisma de ventrículo esquerdo por rotura cardíaca após infarto agudo do miocárdio: tratamento cirúrgico

    Directory of Open Access Journals (Sweden)

    GOMES Maurício de Castro

    1997-01-01

    Full Text Available O pseudo-aneurisma de ventrículo esquerdo após infarto agudo do miocárdio é entidade rara. Quando diagnosticado, deverá ser operado logo que possível, devido ao risco aumentado de rotura de sua parede. No período de novembro de 1992 a junho de 1995, foram encaminhados ao nosso Serviço 3 pacientes com suspeita clínica de pseudo-aneurisma de ventrículo esquerdo (VE, com sinais clínicos, radiológicos, ecocardiográficos e angiográficos característicos da lesão. O objetivo do trabalho é discutir o diagnóstico, a indicação cirúrgica, as técnicas e táticas empregadas, as complicações e os resultados cirúrgicos. Todos os pacientes foram submetidos ao ecodopplercardiograma transtorácico, que foi suficiente para o diagnóstico. Após propedêutica adequada, com realização de angiografia e ventriculografia, os pacientes foram submetidos à correção utilização de pericárdio bovino. Um dos pacientes apresentava comunicação interventricular (CIV, que foi corrigida no mesmo ato cirúrgico. Os pacientes receberam alta em bom estado geral, com controle ecocardiográfico evidenciando a correção do pseudo-aneurisma.

  20. Síndrome da disfunção apical reversível (Takotsubo Transient ventricular dysfunction (Takotsubo cardiomyopathy

    Directory of Open Access Journals (Sweden)

    José Marconi Almeida de Sousa

    2005-04-01

    Full Text Available Homem portador de miastenia gravis, internado por descompensação da doença de base, em insuficiência respiratória aguda. Na evolução, apresentou quadro sugestivo de infarto agudo do miocárdio, com alterações eletrocardiográficas e enzimáticas compatíveis com o diagnóstico. Submetido a coronariografia de urgência, não evidenciou obstrução coronariana grave, entretanto o ventrículo esquerdo apresentava disfunção sistólica importante, com alteração característica pela ventriculografia da síndrome descrita como disfunção ventricular transitória ou síndrome de Takotsubo. Na evolução, houve completa recuperação das alterações eletrocardiográficas e da função ventricular sistólica avaliada pelo ecocardiograma, confirmando a síndrome.The patient was a male with myasthenia gravis, hospitalized with acute respiratory failure due to decompensation of the underlying disease. He evolved with findings suggestive of acute myocardial infarction, with electrocardiographic and enzymatic alterations compatible with that diagnosis. The patient underwent emergency coronary angiography, which showed no severe coronary obstruction, although his left ventricle had significant systolic dysfunction with characteristic alterations, on ventriculography, of the syndrome described as transient ventricular dysfunction or Takotsubo syndrome. On evolution, complete recovery of the electrocardiographic alterations and systolic ventricular function assessed on echocardiography occurred, confirming the syndrome.

  1. Circulação coronária dependente do ventrículo direito na atresia pulmonar com septo interventricular íntegro. Ausência da origem das artérias coronárias da aorta Right ventricle-dependent coronary circulation in pulmonary atresia with intact ventricular septum. Absence of origin of the coronary arteries from the aorta

    Directory of Open Access Journals (Sweden)

    Ivan Romero Rivera

    1998-08-01

    Full Text Available São descritos os aspectos clínicos, ecocardiográficos e angiográficos de um neonato de sexo masculino, com cinco dias de vida e diagnóstico de atresia pulmonar com septo interventricular íntegro. Tanto o ecocardiograma como a aortografia mostraram ausência da origem das artérias coronárias da aorta. O ecocardiograma bidimensional e, posteriormente, a ventriculografia direita identificaram as artérias coronárias, originando-se no ventrículo direito. Não houve contrastação retrógrada da aorta ou do tronco pulmonar quando contrastadas as artérias coronárias. Este é o primeiro caso relatado com diagnóstico ecocardiográfico pré angiografia, e é um exemplo da necessidade de se avaliar as artérias coronárias em pacientes com atresia pulmonar e septo ventricular íntegro.This report describes the clinical, echocardiographic and angiographic aspects of a five-day old boy with pulmonary atresia and intact ventricular septum. Both the echocardiogram and the aortography did not show any coronary arteries arising from the aorta. Two-dimensional echocardiography was able to identify the coronary arteries originating from the right ventricle and so did the right ventricular angiogram. No retrograde flow into the aorta or pulmonary trunk was identified after opacification of the coronary arteries. As far as we know this is the first case diagnosed by echocardiography, and is a vivid example of the necessity of identifying the coronary arteries in patients with pulmonary atresia and intact ventricular septum.

  2. Tumor da região do terceiro ventrículo diagnóstico eletrencefalográfico

    Directory of Open Access Journals (Sweden)

    Paulino W. Longo

    1948-06-01

    Full Text Available Depois de rápidas considerações sobre as dificuldades do diagnóstico topográfico dos tumores da região do terceiro ventrículo e sobre as aquisições recentes da eletrencefalografia nesse sentido, os AA. apresentam a observação de uma paciente de 36 anos de idade, com história de 4 meses, portadora de uma síndrome de hipertensão intracraniana grave, acompanhada de hemiparesia esquerda muito discreta e alterações psíquicas. O exame do liqüido cefalorraquidiano revelou hipertensão e a eletrencefalografia evidenciou alterações difusas e bilaterais, ao lado de surtos persistentes e repetidos de ritmo teta, simétrica e sincronicamente reproduzidos, em áreas centrais e parietais de ambos os hemisférios, bem como ondas de ritmo delta focal, no lobo frontal direito, com típicas figuras de reversão. Os primeiros foram atribuídos ao edema cerebral e à hipertensão intracraniana, enquanto que estas (as ondas de ritmo teta acompanhadas de ritmo delta focal frontal direito foram interpretadas como dependentes de tumor cerebral profundamente situado, mediano, da região do terceiro ventrículo, comprometendo secundariamente o lobo frontal direito. A ventriculografia, em parte, e a intervenção cirúrgica subseqüente, confirmaram o diagnóstico, revelando a existência de um tumor cístico pediculado, que, da sela turca invadia o terceiro ventrículo e a parte profunda do lobo frontal direito (craniofaringioma.

  3. Síndrome de Dandy-Walker: a propósito de 4 casos

    Directory of Open Access Journals (Sweden)

    Gilberto Machado de Almeida

    1960-09-01

    Full Text Available Dá-se o nome de síndrome de Dandy-Walker a um tipo de hidrocefalia cuja principal característica é a transformação do IV ventrículo em um grande cisto, que ocupa quase tôda a fossa posterior; esta, por sua vez, está aumentada, devido à elevação da tenda do cerebelo e abaulamento do occipital. A patogenia do processo é discutida; admite-se geralmente que se trate de um vício de desenvolvimento determinado pela falta de abertura dos orifícios de Luschka e Magendie. Em revisão bibliográfica foram encontrados 60 casos. São apresentados mais 4, dois dos quais foram submetidos à derivação ventrículo-jugular pela técnica de Spitz-Holter. São discutidos os principais sinais clínicos, os exames subsidiários e a terapêutica. A posição anormalmente alta dos seios transversos, observada no craniograma ou na sinugrafia, é considerada como sinal patognomônico. A transiluminação do crânio também pode apresentar aspecto característico. Êstes exames, quando típicos, permitem evitar a realização de exames mais traumatizantes, como as ventriculografias. A terapêutica mais empregada tem sido a abertura da parede do cisto. Não há na literatura referência à operação de Spitz que, em nossa opinião, é a melhor forma de tratamento.

  4. Incidência de coronariopatia após o transplante cardíaco ortotópico Incidence of coronariopathy after orthotopic heart transplantation

    Directory of Open Access Journals (Sweden)

    Alfredo I Fiorelli

    1994-06-01

    Full Text Available O presente estudo tem por finalidade analisar tardiamente o padrão anatômico evolutivo das artérias coronárias do coração transplantado. Para cumprir tal proposição foram selecionados 22 pacientes submetidos ao transplante cardíaco ortotópico, com seguimento pós-operatório superior a 36 meses. As variáveis eleitas para este fim foram aferidas anualmente até o quinto ano de pós-operatório. A análise da ventriculografia mostrou a estabilidade da fração de ejeção (p=0,99 em valores normais. A cineangiocoronariografia seqüencial evidenciou incidência crescente de lesões arteriais com comprometimento da função contrátil. As lesões obstrutivas acometeram as artérias coronárias difusamente, com predomínio no território distai. Os episódios de rejeição aguda e a etiologia da cardiomiopatia não modificaram a evolução natural da aterosclerose coronária.The purpose of this study was to analise late anatomical status of coronary arteries in patients (pts in whom orthotopic heart transplantation(OHT was perfomed. We studied 22 pts submitted to OHT with post-operative follow-up longer than 36 months. They were evaluated by cinecoronariography every year in a 5 years follow-up. Ventriculography analisis showed stability (in normal values of the left ventricular ejection fraction (p= 0,99 during the follow-up period. The sequential coronary studies showed a progressive increase on incidence of abnormalities in coronary arteries with disorders of contratile function. The obstructive abnormalities were present in all segments but more in distal territories. The acute rejection episodes and cardiomiopathy etiologies didn't change the natural evolution of coronary atherosclerosis.

  5. Infarto do miocárdio causado por lesão arterial coronariana após trauma torácico fechado Infarto de miocardio causado por lesión arterial coronaria post traumatismo torácico cerrado Myocardial infarction caused by coronary artery injury after a blunt chest trauma

    Directory of Open Access Journals (Sweden)

    Márcio Silva Miguel Lima

    2009-07-01

    Full Text Available Relatamos o caso de um indivíduo do sexo masculino de 29 anos de idade, vítima de um acidente de carro no qual sofreu trauma torácico fechado, evoluindo com insuficiência cardíaca congestiva. O paciente apresentava boa saúde previamente, sem sintomas de doença cardiovascular. Na avaliação inicial, o eletrocardiograma mostrou ondas Q nas derivações precordiais e o ecocardiograma mostrou disfunção ventricular esquerda importante. A angiografia coronária mostrou uma lesão na artéria coronária descendente anterior esquerda (ADE, com acinesia da parede anterior na ventriculografia com contraste. A tomografia computadorizada por emissão de fóton único (SPECT com Tálio-201 não mostrou viabilidade. O paciente foi mantido em tratamento clínico com boa evolução.Relatamos el caso de un individuo del sexo masculino, de 29 años de edad, víctima de accidente automovilístico en el cual sufrió traumatismo torácico cerrado, evolucionando con insuficiencia cardíaca congestiva. El paciente presentaba buena salud previamente, sin síntomas de enfermedad cardiovascular. En la evaluación inicial, el electrocardiograma mostró ondas Q en las derivaciones precordiales y el ecocardiograma mostró disfunción ventricular izquierda importante. La angiografía coronaria mostró una lesión en la arteria coronaria descendente anterior izquierda (ADI, con acinesia de la pared anterior en la ventriculografía de contraste. La tomografía computada por emisión de fotón único (SPECT con Talio-201 no mostró viabilidad. El paciente fue mantenido en tratamiento clínico con buena evolución.We report the case of a 29-year-old man, victim of a car accident, who suffered a severe blunt chest trauma, with evolving congestive heart failure. He had previously had a good overall health status, with no symptoms of cardiovascular disease. At the initial assessment, the electrocardiogram showed Q waves in the precordial leads and the echocardiogram

  6. Partial left ventriculectomy in a child: 70-month clinical follow up Ventriculectomia parcial esquerda em criança: acompanhamento clínico por 70 meses

    Directory of Open Access Journals (Sweden)

    Eduardo Coelho de Souza

    2003-10-01

    Full Text Available We describe the 70- month follow up of a child with idiopathic dilated cardiomyopathy and end-stage congestive heart failure (NYHA III/IV who underwent partial left ventriculectomy - the Batista operation when he was two and half years old. The clinical follow up was performed in the outpatient clinic by electrocardiography, echocardiography and radionuclide ventriculography to better analyse the left ventricular ejection fraction. The left ventricular diameter increased. Echocardiograms showed enlargement mainly in the systolic left ventricular diameter and slow decrease in fractional shortening (delta D. The child was in class I (NYHA during the follow-up. His exercise endurance was better than before surgery and hospitalization was not necessary. For these reasons, we believe that this procedure can be considered as a therapeutic option in children with severe dilated cardiomiopathy who are waiting for heart transplantation, as the shortage of donors is a fact.Relatamos a evolução durante 70 meses de uma criança submetida a ventriculectomia parcial esquerda, pela técnica de Batista aos 2 anos e 6 meses de idade, em classe funcional III/IV em decorrência de cardiomiopatia dilatada idiopática, com seguimento clínico ambulatorial. Realizamos eletrocardiogramas, ecocardiogramas seriados e ventriculografia radioisotópica para melhor analisar a fração de ejeção do ventrículo esquerdo. Houve progressivo aumento deste. O ecocardiograma mostrou aumento principalmente do diâmetro sistólico do ventrículo esquerdo com queda progressiva, porém lenta, da fração de ejeção. Apesar da progressão da disfunção miocárdica, a criança manteve-se em classe funcional I durante todo o seguimento, com melhora da tolerância ao exercício e não necessitou de internações. Por isso, achamos que o método pode ser considerado opção terapêutica em crianças com cardiomiopatia dilatada avançada, aguardando a indicação mais tardia de

  7. Miocárdio não compactado em paciente com infarto agudo do miocárdio Miocardio no compactado en paciente con infarto agudo de miocardio Noncompaction of the myocardium in a patient with acute myocardial infarction

    Directory of Open Access Journals (Sweden)

    Emanuel Correia

    2010-05-01

    Full Text Available Miocárdio não compactado (MCNC é uma cardiopatia congênita rara, resultado da falha na compactação do miocárdio, levando à persistência de trabeculações numerosas e profundas, comunicantes com a cavidade ventricular. Tem como principais manifestações clínicas: insuficiência cardíaca, eventos arrítmicos (supraventriculares ou ventriculares e episódios de embolismo arterial. Apresenta-se o caso de um cidadão brasileiro residente em Portugal internado por infarto agudo do miocárdio, do qual resultou disfunção sistólica severa do ventrículo esquerdo. No decorrer do estudo diagnosticou-se MCNC. Descreve-se a apresentação clínica, ecocardiográfica (bidimensional e tridimensional, imagem de ressonância magnética nuclear (RMN e ventriculografia. Discutem-se os critérios diagnósticos e opções terapêuticas.El miocardio no compactado (MCNC es una cardiopatía congénita rara, resultado de la falla en la compactación del miocardio, y ocasiona la persistencia de trabeculaciones numerosas y profundas, comunicantes con la cavidad ventricular. Tiene como principales manifestaciones clínicas: insuficiencia cardiaca, eventos arrítmicos (supraventriculares o ventriculares y episodios de embolismo arterial.Left-ventricular non-compaction (LVNC is a rare congenital cardiopathy, which results from the failure of the myocardial compaction process, leading to the persistence of numerous and deep trabeculations communicating with the ventricular cavity. Its main clinical manifestations are heart failure, arrhythmias (supraventricular or ventricular and episodes of arterial embolism. The present case reports on a Brazilian patient living in Portugal, who was hospitalized due to acute myocardial infarction, which resulted in severe LV systolic dysfunction. During the patient's assessment, LVNC was diagnosed. The clinical presentation is described, as well as the echocardiographic evaluation (two-dimensional and three

  8. Delayed metamorphosis in decapod crustaceans: evidence and consequences Retraso de la metamorfosis en crustáceos decápodos: evidencias y consecuencias

    Directory of Open Access Journals (Sweden)

    PAULINA GEBAUER

    2003-06-01

    hormonally mediated effects on the moulting cycle, the quantification of energetic or other costs of delayed metamorphosis, and the analysis of relationships between the effectiveness of adult odors and phylogenetic proximity of larvae and adultsNumerosos invertebrados marinos tienen un ciclo de vida bifásico, el cual incluye una fase larval planctónica y una juvenil-adulta bentónica. La metamorfosis y asentamiento son los eslabones entre estas dos fases del desarrollo. La metamorfosis en muchas especies es gatillada por estímulos físicos y/o químicos, generalmente relacionados con el hábitat parental. Las larvas competentes, en ausencia de estos inductores, pueden retardar la metamorfosis desde algunos días hasta meses. La mayoría de las investigaciones sobre retraso de la metamorfosis han sido realizadas en especies sedentarias o sésiles. En crustáceos decápodos (móviles la cantidad de estudios relacionados con la inducción del asentamiento y metamorfosis por estímulos específicos y la capacidad de retraso de la metamorfosis es mucho menor, y se podría deber a que este grupo no pierde su capacidad de movimiento post-metamorfosis, por lo cual el hábitat de asentamiento y metamorfosis podría no ser tan crucial para este grupo como en las especies sésiles o sedentarias. Sin embargo, en algunas especies de crustáceos decápodos se ha reportado la importancia de la presencia de estímulos específicos para el asentamiento y metamorfosis y la flexibilidad en el momento de la metamorfosis en ausencia de tales estímulos. En general, los estímulos identificados que gatillan la metamorfosis son algunos tipos de substratos, la presencia de adultos conespecíficos o congenéricos. La capacidad de retraso de la metamorfosis en las especies de decápodos estudiadas es limitada y generalmente finaliza con una metamorfosis espontánea. La prolongación del tiempo de desarrollo presenta ventajas ya que aumenta la probabilidad de localizar un hábitat favorable y

  9. Radioisotope Power Sources; Sources d'energie utilisant les radiobotopes; Radioizotopnye istochniki ehnergii; Fuentes radio isotopicas de energia

    Energy Technology Data Exchange (ETDEWEB)

    Culwell, J. P. [USAEC, Washington, D.C (United States)

    1963-11-15

    satellite TRANSIT, place sur orbite par la Marine americaine, est equipe d'un generateur thermoelectrique au plutonium-238 comme source d'energie electrique. Des generateurs sont a l'etude pour les projets spatiaux du Bureau de l'Aeronautique et de l'Administration de l'espace americains. En raison des grandes quantites de radioactivite que comportent les sources d'energie utilisant des radioisotopes, il faut accorder une grande attention a la securite de ces appareils. Pour s'assurer que l'on peut les utiliser sans creer de risques inutiles, on a etabli des normes de securite rigoureuses et procede a des essais tres pousses. (author) [Spanish] El programa de la Comision de Energia Atomica de los Estados Unidos en materia de energia electrica generada por radioisotopos ha dado origen a toda una nueva tecnologia cuyo objeto es el empleo de radioisotopos como fuentes de energia en los generadores de electricidad. Las fuentes radioisotopicas se prestan en particular para aplicaciones a distancia en las que se necesita una fuente de energia duradera, poco voluminosa y de funcionamiento seguro. Capaces de funcionar satisfactoriamente en las condiciones mas extremas de temperatura y exposicion a la luz solar y radiaciones electromagneticas, estas ''baterias nucleares'' constituyen fuentes interesantes de energia para dispositivos de acopio de datos controlados a distancia, sistemas de vigilancia, satelites y otros vehiculos espaciales. Los radioisotopos utilizados como fuente de energia son habitualmente emisores alfa o beta. Los emisores alfa son preferibles, pero tambien mas caros y menos abundantes que los emisores beta y se reservan por lo general para usos espaciales. En la actualidad los emisores beta obtenidos de los productos de fision procedentes de los reactores se utilizan exclusivamente para aplicaciones terrestres y maritimas. No obstante, es de esperar que con el transcurso del tiempo los emisores beta tales como el estroncio-90 se emplearan en el espacio. Se estan

  10. The production of radioisotopes with a betatron using an internal bombarding technique; Production de radioisotopes par bombardement interne dans un betatron; Proizvodstvo radioizotopov s pomoshch'yu betatrona s ispol'zovaniem metoda vnutrennej bombardirovki; Obtencion de radioisotopos por bombardeo interno en el betatron

    Energy Technology Data Exchange (ETDEWEB)

    Morinaga, H [Department of Physics, Tohoku University, Sendai (Japan)

    1962-01-15

    des cibles internes n'a ete employee que pour les travaux de spectroscopie nucleaire; elle a permis d'identifier huit nouvelles especes d'isotopes radioactifs (cobalt-63, gallium-75, arsenic-81, indium-121, indium-123, thulium-173, thulium-175 et actinium-231) et de decouvrir plusieurs nouveaux isomeres. L'efficacite de cette technique de bombardement ouvre de nouvelles perspectives, car les betatrons employes a des fins medicales ou industrielles ou pour la recherche peuvent aussi servir a la production de radioelements. Les radioisotopes de courte periode sont souvent plus commodes a utiliser dans diverses applications en raison de leur desintegration rapide et des rayonnements de haute energie qu'ils emettent, et peuvent etre fabriques facilement sans exiger d'operations compliquees. (author) [Spanish] El autor ha ideado y empleado con exito un nuevo metodo para obtener en el betatron radioisotopos de elevada actividad especifica. Los materiales que se desee activar se colocan en el extremo de una varilla que se introduce desde el exterior en el tubo toroidal, y se irradian a la presion de una atmosfera en un lugar situado inmediatamente detras clel blanco que emite las radiaciones de frenado, en el que la intensidad de las radiaciones es extremadamente elevada. El autor produjo en una pieza pequena de cobre una actividad de saturacion de {sup 62}Cu superior a un milicurie, y la actividad especifica mas elevada que pudo alcanzar era unas 500 veces mayor que la obtenida con ayuda de los dispositivos corrientes. Por ahora, la tecnica del blanco interior solo se emplea para trabajos de espectroscopia nuclear. El autor ha Identificado por este metodo ocho nuevas especies radioisotopicas ({sup 63}Co, {sup 75}Ga, {sup 81}As, {sup 121}In, {sup 123}In, {sup 173}Tm, {sup 175}Tm y {sup 231}Ac) y ha encontrado varios nuevos isomeros. Esta tecnica de bombardeo abre posibilidades nuevas porque los betatrones que hoy se emplean en medicina, en la industria o en la investigacion

  11. The use of Kr{sup 85} for the measurement of leaks in hermetically sealed components; Emploi du krypton-85 pour la detection des fuites dans les pieces hermetiquement scellees; Opredelenie utechki germeticheski izolirovannykh komponentov pri pomoshchi Kr''8''5; Empleo del {sup 85}Kr para la deteccion de fugas en piezas hermeticamente selladas

    Energy Technology Data Exchange (ETDEWEB)

    Berry, P F; Cameron, J F [Wantage Research Laboratory (A. E. R. E.), Wantage, Berks. (United Kingdom); Wilson, E J [Radiochemical Centre, Amersham, Bucks. (United Kingdom)

    1962-01-15

    introduire du gaz actif dans la piece avant de la sceller; la perte d'activite qui se produit par la suite permet de mesurer l'importance de la fuite. La methode adoptee depend des dimensions de l'element et de ce que l'on veut en faire. La principale limitation de la premiere methode, en ce qui concerne la sensibilite, est la contamination de la surface qui se produit par suite de l'absorption de gaz dans les pores du materiau dont est fait l'element; l'importance de cette absorption est examinee a propos de l'application de la methode a la detection des fuites dans les gaines de transistors. Le remplissage prealable de l'element avec un gaz actif offre l'avantage de rendre possible un controle du contenu de l'element sur une longue periode. Cela elimine la possibilite d'une interruption temporaire de la fuite, comme il peut s'en produire si l'on emploie l'autre methode, et l'on obtient en outre des donnees plus utiles puisqu'elles indiquent l'importance totale des fuites eventuelles. (author) [Spanish] La deteccion de fugas en piezas hermeticamente selladas puede realizarse con ayuda de gases radiactivos; en determinados casos la sensibilidad de la tecnica radioisotopica puede superar en varios ordenes.de magnitud a la de los metodos clasicos. Los autores describen la utilizacion del {sup 85}Kr para este fin. El gas puede emplearse de dos maneras. La primera consiste en sumergir la pieza en una atmosfera de dicho gas durante im tiempo y a una presion establecidos, y calcular seguidamente la cantidad que ha penetrado en su interior midiendo la intensidad de las radiaciones que atraviesan las paredes de la pieza. El segundo metodo consiste en introducir un gas radiactivo en la pieza antes de proceder a su cierre. En este caso, la disminucion de actividad subsiguiente constituye un indice de la velocidad de escape. La eleccion del metodo depende de las dimensiones de la pieza y del uso a que esta se destine. La contaminacion de la superficie debida a la absorcion de gas en

  12. Ventriculectomia parcial: um novo conceito no tratamento cirúrgico de cardiopatias em fase final Partial ventriculectomy: a new concept for surgical treatment of end stage cardiopathies

    Directory of Open Access Journals (Sweden)

    Randas J. V Batista

    1996-03-01

    Full Text Available A melhora clínica da função cardíaca pós aneurismectomia de ventrículo esquerdo e/ou cardiomioplastia com o músculo grande dorsal parece ser, ao menos parcialmente, devida ao remodelamento do ventrículo esquerdo. Através de pesquisa em nosso laboratório experimental com carneiros, demonstramos que o aumento do diâmetro do ventrículo é mais importante que a perda de massa muscular para a deterioração da função ventricular. Sabendo-se que em miocardiopatia dilatada não ocorre aumento de massa muscular, reduzimos o diâmetro do ventrículo para o normal, em uma série consecutiva de pacientes com esta lesão. No período de 1984 a 1995, foram operados com esta nova técnica, denominada, então, "Ventriculectomia Parcial", 103 pacientes portadores de miocardiopatias complexas e insuficiência cardíaca congestiva (NYHA IV. A operação é baseada na lei de Laplace (T=P.11.D e consistiu na remoção de uma fatia de músculo da parede lateral do ventrículo esquerdo, iniciando-se na ponta deste, estendendo-se entre os músculos papilares e terminando próximo ao anel mitral. A cirurgia é realizada sob circulação extracorpórea normotérmica e não se utiliza cardioplegia. "Todos os pacientes foram avaliados pré-operatoriamente com ecodopplercardiografia e ventriculografia digital, os quais revelaram fração de ejeção The clinical improvement of cardiac function post left ventricular aneurysmectomy and/or cardiomyoplasty with the latissimus dorsi muscle seems to be due to the remodeling of the left ventricle. We did some experiments with sheep in our laboratory and we concluded that the increment of ventricular diameter is more deleterious than loss of muscle mass to the ventricular function. Since there is no increment in muscle mass to the dilated hearts, we reduced their diameter to accomplish a better ventricular function in a series of very sick patients with dilated hearts. From 1984 to 1995, 103 patients with complex

  13. Avaliação quantitativa da movimentação parietal regional do ventrículo esquerdo na endomiocardiofibrose Quantitative assessment of left ventricular regional wall motion in endomyocardial fibrosis

    Directory of Open Access Journals (Sweden)

    Charles Mady

    2005-03-01

    Full Text Available OBJETIVO: Analisar a movimentação parietal regional do ventrículo esquerdo (VE em pacientes com endomiocardiofibrose (EMF. MÉTODOS: Estudados 88 pacientes, 59 do sexo feminino, com idade média de 39±13 anos (variação de 9 a 65 com evidência ecocardiográfica e angiográfica de EMF do VE. A intensidade da deposição de tecido fibroso na cineventriculografia contrastada foi classificada como discreta, moderada ou importante. A fração de ejeção global do ventrículo esquerdo (FEVE foi determinada pelo método área-comprimento por meio da ventriculografia. O movimento foi medido em 100 cordas eqüidistantes e perpendiculares à linha média desenhada no meio dos contornos diastólico e sistólico finais e normalizadas para o tamanho cardíaco. Analisaram-se cinco segmentos do VE: A - apical; AL - ântero-lateral; AB - ântero-basal; IA - ínfero-apical; IB - ínfero-basal. A anormalidade foi expressa em unidades de desvio padrão do movimento médio em uma população de referência normal, composta por 103 pacientes com VE normal, conforme dados de clínica, eletrocardiograma e padrões angiográficos. RESULTADOS: A FEVE média foi de 0,47±0,12. O envolvimento de tecido fibroso do VE foi discreto em 12 pacientes, moderado em 40 e importante em 36. As regiões com pior movimentação parietal foram A (-1,4±1,6 desvio-padrão/cordas e IA (-1,6±1,8 desvio-padrão/cordas comparadas com AB (-0,3±1,9 desvio-padrão /cordas, AL (-0,5±1,8 desvio-padrão/cordas e IB (-0,9±1,3 desvio-padrão/cordas. Não se observou relação entre a intensidade de envolvimento do tecido fibroso e a manutenção parietal regional. CONCLUSÃO : Existe alteração da movimentação parietal regional na EMF e é independente da intensidade de deposição de tecido fibroso avaliada qualitativamente. O envolvimento não uniforme do VE deve ser levado em conta no planejamento cirúrgico dessa doença.OBJECTIVE: To analyze left ventricular (LV regional wall

  14. Recent Advances in Food Irradiation Research in Japan; Recents Progres de l'Irradiation des Produits Alimentaires au Japon; Poslednie dostizheniya v issledovaniyakh po oblucheniyu produktov pitaniya v Yaponii; Progresos Recientes de las Investigaciones Sobre Irradiacion de Alimentos Realizadas en el Japon

    Energy Technology Data Exchange (ETDEWEB)

    Matsuyama, A. [Laboratory of Radiation Biology, Institute of Physical and Chemical Research, Honkomagome, Bunkyo-Ku, Tokyo (Japan)

    1966-11-15

    , les modifications de qualite decelables immediatement apres l'irradiation se sont revelees insignifiantes apres huit mois de conservation d'apres l'analyse statistique des donnees organoleptiques. Deuxiemement, etude de l'elimination des agents biologiques et biochimiques nuisibles dans les produits, du point de vue de la sante publique. La sensibilite aux rayonnements de la toxine produite par Cl. botulinum E a ete etudiee en rapport avec l'innocuite des produits irradies. Troisiemement, l'utilisation des effets chimiques des rayonnements. On a etudie par exemple l'irradiation d'algues marines a des doses de 0,5 a 0,7 Mrad en vue d'ameliorer la qualite et la quantite de la gelose extraite, ainsi que l'acceleration, par des doses de rayonnement atteignant 0,5 Mrad, du vieillissement des boissons alcooliques, notamment des liqueurs distillees. Outre ces etudes de caractere pratique, on s'est occupe activement des problemes fondamentaux comprenant la radiosensibilisation des micro-organismes, l'inactivation des enzymes par les rayonnements et d'autres questions de radiochimie interessant l'irradiation des denrees alimentaires. (author) [Spanish] En la actualidad parecen perfilarse los planes para establecer en el Japon un programa nacional de irradiacion de alimentos orientado hacia los problemas fundamentales y practicos. La Comision de Energia Atomica ha comenzado ya a preparar el programa de estudios fundamentales y sus aplicaciones, que se emprendera probablemente en 1967. Gracias a la colaboracion de especialistas se ha constituido la Sociedad japonesa de investigaciones sobre irradiacion de alimentos; se espera que esta organizacion desempene una labor importante en la ejecucion del programa nacional. En la actualidad, el Japon dispone de unas 30 fuentes radioisotopicas del orden del kilocurie, y casi del mismo numero de generadores de electrones, incluidas varias plantas piloto de irradiacion. En el Japon los estudios practicos sobre irradiacion de alimentos se

  15. Preliminary Note on the Use of Radioisotopes to Study Some Cotton-Plant Pests in Africa; Note preliminaire sur l 'utilisation des radioisotopes dans l 'etude des parasites du cotonnier en afrique; Predvaritel'nye zamechaniya o primenenii radioizotopov dlya izucheniya nekotorykh vreditelej khlopchatnika v afrike.; Nota preliminar sobre el empleo de radioisotopos en el estudio de parasitos del algodonero en africa

    Energy Technology Data Exchange (ETDEWEB)

    Delattre, R. [Institut de Recherches du Coton et Textiles, Paris (France)

    1963-09-15

    appliques sur des cotonniers ages, juste avant la periode de mise en diapause naturelle de Diparopsis. Les resultats d'ensemble laissent esperer que l'on pourra sans trop de difficultes distinguer, parmi les populations de chrysalides prelevees dans le sol, celles nourries sur le cotonnier avant qu'il ne soit marque, donc qui auront subi une diapause. Une contre-experience sera ensuite necessaire; elle consistera a marquer, en cours de saison, les cotonniers d'un champ ayant deja porte la meme culture Tannee precedente, les chrysalides sans diapause etant cette fois marquees. Des observations annexes sont egalement en cours sur divers autres parasites du cotonnier. (author) [Spanish] La oruga de Diparopsis watersi Roth es perjudicial para el algodonero, pues destruye sus flores y capsulas. Este noctuido, practicamente monofago, pasa el periodo interestacional bien en el suelo en forma de crisalidas en diapausa a partir del 10 de noviembre, bien por generaciones continuas (especies que se reproducen varias veces al ano) en las plantas sin arrancar. Los estudios de laboratorio han permitido dilucidar los principales mecanismos que determinan e l comienzo y el fin de la diapausa. En la naturaleza, las pululaciones durante el cultivo provienen de individuos de una sola generacion al ano, que alcanzan la eclosion hacia abril o mayo, asi como de generaciones sin diapausa. Deberia averiguarse con suficiente exactitud el papel que desempenan estas dos cepas diferentes, para determinar los medios de lucha mas apropiados: arranque del algodonero, destruccion de las ninfas durante la diapausa en el suelo, anticipacion de la campana, etc. La marcacion radioisotopica de las orugas que alcanzan la madurez en las epocas criticas permitiria seguramente abordar este problema en el plano practico. En Tikem (Republica del Chad) se han realizado experimentos preliminares para preparar tecnicas sencillas de marcacion. En el primer ensayo se aplico {sup 32}P en pulverizacion acuosa directa sobre

  16. Some Recent Applications of Short Half-Life Radioisotopes in Australia; Quelques Applications Recentes des Radioisotopes a Courte Periode En Australie; НОВЕЙШИЕ СПОСОБЫ ИСПОЛЬЗОВАНИЯ В АВСТРАЛИИ КОРОТКОЯИВУЩИХ РАДИОИЗОТОПОВ; Algunas Recientes Aplicaciones de los Radioisotopos de Periodo Corto en Australia

    Energy Technology Data Exchange (ETDEWEB)

    Watt, J. S. [Australian Atomic Energy Commission Research Establishment, Lucas Heights, NSW (Australia)

    1963-03-15

    l'eau. (author) [Spanish] La memoria describe el empleo de radioisotopos de periodo corto en algunas de las investigaciones sobre el terreno que recientemente ha realizado la Division de Isotopos de la Comision de Energia Atomica de Australia. Se esta estudiando una tecnica radioisotopica para seguir los desplazamientos del aire en las nubes; dicha tecnica se empleara principalmente en experimentos sobre siembra de nubes con sustancias que provocan la lluvia. En una serie de diez experimentos, se lanzaron desde un avion cantidades de hasta 2 c de cobre-64 en forma de CuO finamente dividido, cuyo desplazamiento se observo detectando con un contador de centelleo de cristal de grandes dimensiones las radiaciones gamma emitidas por el CuO distribuido en tomo al avion. Una novedad del metodo consiste en que notolo mide la radiactividad, sino tambien la direccion en que esta situada la fuente de radiaciones. Esto permite orientar al avion hacia el foco de la radiactividad. Se esta estudiando una tecnica para investigar la contaminacion del aire y metodos de ventilacion en gran escala. Para ello, se liberaran pequenas cantidades de cobre-64, sea en forma de polvo de CuO o de cobre adsorbido en particulas, y se recogeran en papel de filtro, utilizando un aparato para tomar muestras de aire a gran velocidad. Los experimentos demuestran que se logra una discriminacion perfecta con respecto a la radiactividad natural del aire empleando tecnicas de coincidencia {gamma}-{gamma} para detectar el par que se produce por la aniquilacion positron-electron del cobre-64. La concentracion minima detectable es del orden de los 1 * 10{sup -18} c de cobre-64 por cm{sup 3} de aire. Se describe un metodo para localizar escapes de gas en la red de distribucion urbana. Los escapes en ramales individuales entre la tuberia principal y el contador se detectan con unos-500 pe de bromuro de metilo marcado con bromo-82, y una peculiaridad del metodo es que permite recuperar casi todo el gas

  17. The Digital Autofluoroscope; L'Autofluoroscope Numerique; Tsifrovoj avtofluoroskop; Autofluoroscopio Numerico

    Energy Technology Data Exchange (ETDEWEB)

    Bender, M. A. [Roswell Park Memorial Institute, Buffalo, NY (United States)

    1964-10-15

    los conductores de luz permite almacenar los datos en nucleos magneticos y analizarlos cuantitativamente por representacion continua no destructiva en un osciloscopio en escala l a l por impresion de datos numericos. La primera ventaja que el autofluoroscopio tiene sobre los aparatos corrientes de exploracion radioisotopica consiste en reducir notablemente el tiempo necesario para efectuar el examen. Utilizando el mismo plan de dosificacion, los tumores del cerebro o del hfgado se localizan con la decima parte del tiempo que requiere una exploracion corriente. La segunda ventaja estriba en que se reunen simultaneamente datos para todo el organo. Ello permite visualizar procesos dinamicos y emplear isotopos o compuestos marcados de periodo fisico o biologico extremadamente corto. Al disminuir el periodo se puede aumentar la dosis administrada y reducir aun mas el tiempo necesario para el examen. Los tiempos de exposicion pueden ser tan cortos que actualmente se emplean tecnicas cinematograficas para visualizar y determinar cuantitativamente el paso del Hipuran marcado con yodo-131 por los rinones, o el paso del bario-137m por las cavidades del corazon. (author) [Russian] Avtofluoroskop javljaetsja stacionarnym priborom, prednaznachennym dlja poluchenija graficheskogo izobrazhenija raspredelenija gamma-izluchajushhih radioizotopov v chelovecheskom or gan i zme. Jetot pribor soch et a et vazhnye cherty sovr em en nyh skennerov, vkljuchaja kollimaciju, s horoshej glubinoj chuvstvitel'nosti i d ostatochnoj razreshajushhej sposobnost'ju, vysokoj jeffektivnost'ju i vysokokontrastnoj sist emoj predstavlenija dannyh. Detektor sostoit iz 300 kristallov NaJ (T1 ) tolshhinoj 5 sm i diametrom Jemm, upakovannyh v shtabel' razmerom 15 h 22,5 sm , imejushhij 20 rjadov i 15 grupp. Kazhdyj iz 300 kristallov opticheski soedinen s dvumja svetovymi pleksiglasovymi trubkami, prichem 20 svetovyh trubok iz dannoj gruppy podhodjat k odnoj fototrubke i 15 svetovyh trubok iz dannogo rjada

  18. A Comparison of Radioisotope Methods for River Flow Measurement; Comparaison de methodes radioisotopiques de mesure du debit des cours d'eau; Sravnenie radioizotopnykh metodov izmereniya rechnykh stokov; Comparacion de los metodos radioisotopicos para medir el caudal de los rios

    Energy Technology Data Exchange (ETDEWEB)

    Clayton, C. G.; Smith, D. B. [Wantage Research Laboratory Atomic Energy Research Establishment Wantage, Berks (United Kingdom)

    1963-08-15

    del lecho del rio. Desde este punto de vista, el tritio posee excelentes propiedades, puesto que no es absorbido, pero es dificil de medir y no es posible seguir directamente su desplazamiento en el rio. Otros indicadores resultan mas convenientes, pero pueden sufrir adsorcion. Los autores han estudiado los grados de adsorcion del {sup 24}Na, {sup 82}Br y {sup 32}P en forma de NaHC0{sub 3}, NH{sub 4}Br y NaH{sub 2}PO{sub 3} respectivamente, que introdujeron en un mismo punto del rio junto con agua tritiada (HTO), para comparar despues las mediciones realizadas en varios lugares situados aguas abajo. Se ha visto que el EP, para el que se esperaban grandes perdidas por quimisorcion, no sirve para medir el caudal de rios cuando se emplea sin portador, aunque el error disminuye notablemente cuando se trabaj a con portador. En el caso del {sup 24}Na y del {sup 32}Br, no se observa adsorcion a distancias mucho mayores que la requerida para que la mezcla lateral sea satisfactoria si bien a una distancia de 660 m en el rio de corriente mas lenta se observo que parte del {sup 24}Na habia desaparecido. Los autores formulan algunas observaciones sobre el grado de dispersion lateral y longitudinal que tienen importancia para la aplicacion de tecnicas radioisotopicas en general a la medicion del caudal de rios. Llegan a la conclusion de que los tres metodos pueden dar resultados satisfactorios. En definitiva, los autores dan preferencia al metodo de muestreo continuo, ya que permite alcanzar una mayor precision para un consumo minimo de indicador. (author) [Russian] Metody razbavleniya, nepreryvnogo otbora prob i polnogo scheta primenyayutsya pri sravnitel'nom izuchenii radioindikatornykh metodov izmereniya stokov v rekakh Ajbehrton Bruk v Gluchestershire i Usvej Bern i Alvin Rivers - v Nortamberlehnde. EHto - tri reki s razlichnymi geologicheskimi kharakteristikami i skorostyami stokov, izmenyayushchikhsya v diagyuzone ot 2,5 l/sek do 3 m{sup 3}/sek. Pri ispol'zovanii lyubykh