WorldWideScience

Sample records for ventilated livestock buildings

  1. Mechanisms of natural ventilation in livestock buildings

    DEFF Research Database (Denmark)

    Rong, Li; Bjerg, Bjarne Schmidt; Batzanas, Thomas

    2016-01-01

    Studies on the mechanisms of natural ventilation in livestock buildings are reviewed and influences on discharge and pressure coefficients are discussed. Compared to studies conducted on buildings for human occupation and industrial buildings which focus on thermal comfort, ventilation systems...

  2. Emissions of ammonia and methane from a livestock building natural cross ventilation

    Directory of Open Access Journals (Sweden)

    A.M. Fiedler

    2011-02-01

    Full Text Available Agriculture, especially animal husbandry, is a major source of the greenhouse gas methane as well as the gas ammonia. In order to develop reduction measures for emissions and immissions, two factors prove to be: firstly, to determine the emission mass flow from livestock buildings, and secondly, to understand the dispersion processes in its surroundings. The quantification of emissions from livestock buildings with naturally ventilation is a particularly difficult task. The experimental uncertainties are largely unknown but are expected to be considerable. Using poor quality emission data as model input in dispersion studies (wind tunnel or numerical simulations will produce results with limited significance. Accordingly a field study has been conducted to quantify the emission mass flow from naturally ventilated livestock buildings. During two field campaigns in summer tracer gas experiments and measurements of gas concentrations within and around two naturally ventilated cow sheds in Mecklenburg-Vorpommern were carried out, in order to estimate the emission mass flow. It was found that the measured concentrations within the livestock building strongly depend on outside conditions such as e.g. the wind direction. Large uncertainties also arise from estimates of the air ventilation rate, which determines the emission mass flow. The data analysis shows high estimated ventilation rates of 1280-1380 m3/h/LU (1 LU = 500kg body weight for cow shed 1 and 1140-1180 m3/h/LU for cow shed 2. These results suggest ammonia emission mass flow rates of about 4 g/h/LU for cow shed 1 and about 2 g/h/LU for cow shed 2, respectively.

  3. Methane emission from naturally ventilated livestock buildings can be determined from gas concentration measurements

    DEFF Research Database (Denmark)

    Bjerg, Bjarne; Zhang, Guoqiang; Madsen, Jørgen

    2012-01-01

    Determination of emission of contaminant gases as ammonia, methane, or laughing gas from natural ventilated livestock buildings with large opening is a challenge due to the large variations in gas concentration and air velocity in the openings. The close relation between calculated animal heat...... gas emission and the precision of the estimation are influenced by different calculation procedures, measuring period length, measure point locations, measure point numbers, and criteria for excluding measuring data. The analyses were based on existing data from a 6-day measuring period in a naturally...... ventilated, 150 milking cow building. The results showed that the methane emission can be determined with much higher precision than ammonia or laughing gas emissions, and, for methane, relatively precise estimations can be based on measure periods as short as 3 h. This result makes it feasible...

  4. NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings.

    Science.gov (United States)

    Mendes, Luciano B; Ogink, Nico W M; Edouard, Nadège; van Dooren, Hendrik Jan C; Tinôco, Ilda de Fátima F; Mosquera, Julio

    2015-05-13

    The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS) Gas Monitor and an Open-Path laser (OP-laser). First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a) in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b) the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.

  5. NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

    Directory of Open Access Journals (Sweden)

    Luciano B. Mendes

    2015-05-01

    Full Text Available The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo-Acoustic Spectroscope (PAS Gas Monitor and an Open-Path laser (OP-laser. First, calibrations for the NDIR sensors were obtained in the laboratory. Then, the NDIR sensors were placed in a dairy cow barn for comparison with the PAS and OP-laser methods. The main conclusions were: (a in order to represent the overall barn CO2 concentration of the dairy cow barn, the number of NDIR sensors to be accounted for average concentration calculation was dependent on barn length and on barn area occupation; and (b the NDIR CO2 sensors are suitable for multi-point monitoring of CO2 concentrations in NV livestock barns, being a feasible alternative for the PAS and the OP-laser methods to monitor single-point or averaged spatial CO2 concentrations in livestock barns.

  6. NDIR gas sensor for spatial monitoring of carbon dioxide concentrations in naturally ventilated livestock buildings

    NARCIS (Netherlands)

    Mendes, L.B.; Ogink, N.W.M.; Edouard, Nadège; Dooren, van H.J.C.; Tinoco, I.; Mosquera, Julio

    2015-01-01

    The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost

  7. NDIR Gas Sensor for Spatial Monitoring of Carbon Dioxide Concentrations in Naturally Ventilated Livestock Buildings

    OpenAIRE

    Mendes, Luciano B.; Ogink, Nico W. M.; Edouard, Nad?ge; van Dooren, Hendrik Jan C.; Tin?co, Ilda de F?tima F.; Mosquera, Julio

    2015-01-01

    The tracer gas ratio method, using CO2 as natural tracer, has been suggested as a pragmatic option to measure emissions from naturally ventilated (NV) barns without the need to directly estimate the ventilation rate. The aim of this research was to assess the performance of a low-cost Non-Dispersive Infra-Red (NDIR) sensor for intensive spatial field monitoring of CO2 concentrations in a NV dairy cow house. This was achieved by comparing NDIR sensors with two commonly applied methods, a Photo...

  8. Modeling and Control of Livestock Ventilation Systems and Indoor Environments

    DEFF Research Database (Denmark)

    Wu, Zhuang; Heiselberg, Per; Stoustrup, Jakob

    2005-01-01

    The hybrid ventilation systems have been widely used for livestock barns to provide optimum indoor climate by controlling the ventilation rate and air flow distribution within the ventilated building structure. The purpose of this paper is to develop models for livestock ventilation systems and i...... constraints and random disturbances is designed through system linearization. The well designed control systems are able to determine the demand ventilation rate and airflow pattern, improve and optimize the indoor Thermal Comfort (TC), Indoor Air Quality (IAQ) and energy use....

  9. Computer Prediction of Air Quality in Livestock Buildings

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Bjerg, Bjarne

    In modem livestock buildings the design of ventilation systems is important in order to obtain good air quality. The use of Computational Fluid Dynamics for predicting the air distribution makes it possible to include the effect of room geometry and heat sources in the design process. This paper...... presents numerical prediction of air flow in a livestock building compared with laboratory measurements. An example of the calculation of contaminant distribution is given, and the future possibilities of the method are discussed....

  10. CFD Simulation of Air Velocity Distribution in Occupied Livestock Buildings

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Zhang, G.; Bjerg, B.

    In modem livestock buildings the design of the ventilation systems is important in order to obtain good air distribution. The use of Computational Fluid Dynamics for predicting the air flow and air quality makes it possible to include the effect of room geometry, equipment and occupants in the de....... In this study laboratory measurements in a ventilated test room with "pig simulators" are compared with CFD-simulations....

  11. Model Predictive Control of the Hybrid Ventilation for Livestock

    DEFF Research Database (Denmark)

    Wu, Zhuang; Stoustrup, Jakob; Trangbæk, Klaus

    2006-01-01

    In this paper, design and simulation results of Model Predictive Control (MPC) strategy for livestock hybrid ventilation systems and associated indoor climate through variable valve openings and exhaust fans are presented. The design is based on thermal comfort parameters for poultry in barns...

  12. Preoperational test report, vent building ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  13. Hybrid ventilation systems and high performance buildings

    Energy Technology Data Exchange (ETDEWEB)

    Utzinger, D.M. [Wisconsin Univ., Milwaukee, WI (United States). School of Architecture and Urban Planning

    2009-07-01

    This paper described hybrid ventilation design strategies and their impact on 3 high performance buildings located in southern Wisconsin. The Hybrid ventilation systems combined occupant controlled natural ventilation with mechanical ventilation systems. Natural ventilation was shown to provide adequate ventilation when appropriately designed. Proper control integration of natural ventilation into hybrid systems was shown to reduce energy consumption in high performance buildings. This paper also described the lessons learned from the 3 buildings. The author served as energy consultant on all three projects and had the responsibility of designing and integrating the natural ventilation systems into the HVAC control strategy. A post occupancy evaluation of building energy performance has provided learning material for architecture students. The 3 buildings included the Schlitz Audubon Nature Center completed in 2003; the Urban Ecology Center completed in 2004; and the Aldo Leopold Legacy Center completed in 2007. This paper included the size, measured energy utilization intensity and percentage of energy supplied by renewable solar power and bio-fuels on site for each building. 6 refs., 2 tabs., 6 figs.

  14. Impact of Fire Ventilation on General Ventilation in the Building

    Science.gov (United States)

    Zender-Świercz, Ewa; Telejko, Marek

    2017-10-01

    The fire of building is a threat to its users. The biggest threat is generation, during lifetime of fire, hot gases and smoke. The purpose of quick and efficient evacuation from the area covered by the fire, at first step the escape routes have to be secured from smokiness. The smoke ventilation systems are used for this purpose. The proper design and execution of smoke ventilation is important not only because of the safety, but also of the maintenance of comfort in the building at a time when there is no fire. The manuscript presents the effect of incorrectly realized smoke ventilation in the stairwell of the medium building. The analysis shows that the flaps of smoke ventilation located in the stairwell may have a significant impact on the proper functioning of mechanical ventilation in the period when there is no fire. The improperly installed or incorrect insulated components cause perturbation of air flow and they change pressure distribution in the building. The conclusion of the analysis is the need to include the entire technical equipment of the building during the design and realization of its individual elements. The impact of various installations at each other is very important, and the omission of any of them can cause disturbances in the proper work of another.

  15. Suitability Evaluation of Multipoint Simultaneous CO2 Sampling Wireless Sensors for Livestock Buildings

    OpenAIRE

    Calvet, Salvador; Campelo, José Carlos; Estellés, Fernando; Perles, Angel; Mercado, Ricardo; Serrano, Juan José

    2014-01-01

    [EN] The environment in livestock buildings must be controlled to ensure the health and welfare of both workers and animals, as well as to restrict the emission of pollutants to the atmosphere. Among the pollutants generated inside these premises, carbon dioxide (CO2) is of great interest in terms of animal welfare and ventilation control. The use of inexpensive sensors means that complete systems can be designed with a number of sensors located around the building. This paper ...

  16. Active Fault Tolerant Control of Livestock Stable Ventilation System

    DEFF Research Database (Denmark)

    Gholami, Mehdi

    2011-01-01

    degraded performance even in the faulty case. In this thesis, we have designed such controllers for climate control systems for livestock buildings in three steps: Deriving a model for the climate control system of a pig-stable. Designing a active fault diagnosis (AFD) algorithm for different kinds......). In the FTC part of the thesis, first a passive fault tolerant controller (PFTC) based on state feed-back is proposed for discretetime PWA systems. only actuator faults are considered. By dissipativity theory and H1 analysis, the problem is cast as a set of linear matrix inequalities (LMIs). In the next...... contribution, the problem of reconfigurability of PWA systems is evaluated. A system subject to a fault is considered as reconfigurable if it can be stabilized by a state feedback controller and the optimal cost of the performance of the systems is admissible. In the previous methods the input constraints...

  17. Steady-state balance model to calculate the indoor climate of livestock buildings, demonstrated for finishing pigs

    Science.gov (United States)

    Schauberger, G.; Piringer, M.; Petz, E.

    The indoor climate of livestock buildings is of importance for the well-being and health of animals and their production performance (daily weight gain, milk yield etc). By using a steady-state model for the sensible and latent heat fluxes and the CO2 and odour mass flows, the indoor climate of mechanically ventilated livestock buildings can be calculated. These equations depend on the livestock (number of animals and how they are kept), the insulation of the building and the characteristics of the ventilation system (ventilation rate). Since the model can only be applied to animal houses where the ventilation systems are mechanically controlled (this is the case for a majority of finishing pig units), the calculations were done for an example of a finishing pig unit with 1000 animal places. The model presented used 30 min values of the outdoor parameters temperature and humidity, collected over a 2-year period, as input. The projected environment inside the livestock building was compared with recommended values. The duration of condensation on the inside surfaces was also calculated.

  18. Estimation of NH3 emissions from a naturally ventilated livestock farm using local-scale atmospheric dispersion modelling

    Directory of Open Access Journals (Sweden)

    P. Cellier

    2009-12-01

    Full Text Available Agricultural livestock represents the main source of ammonia (NH3 in Europe. In recent years, reduction policies have been applied to reduce NH3 emissions. In order to estimate the impacts of these policies, robust estimates of the emissions from the main sources, i.e. livestock farms are needed. In this paper, the NH3 emissions were estimated from a naturally ventilated livestock farm in Braunschweig, Germany during a joint field experiment of the GRAMINAE European project. An inference method was used with a Gaussian-3D plume model and with the Huang 3-D model. NH3 concentrations downwind of the source were used together with micrometeorological data to estimate the source strength over time. Mobile NH3 concentration measurements provided information on the spatial distribution of source strength. The estimated emission strength ranged between 6.4±0.18 kg NH3 d−1 (Huang 3-D model and 9.2±0.7 kg NH3 d−1 (Gaussian-3D model. These estimates were 94% and 63% of what was obtained using emission factors from the German national inventory (9.6 kg d−1 NH3. The effect of deposition was evaluated with the FIDES-2D model. This increased the emission estimate to 11.7 kg NH3 d−1, showing that deposition can explain the observed difference. The daily pattern of the source was correlated with net radiation and with the temperature inside the animal houses. The daily pattern resulted from a combination of a temperature effect on the source concentration together with an effect of variations in free and forced convection of the building ventilation rate. Further development of the plume technique is especially relevant for naturally ventilated farms, since the variable ventilation rate makes other emission measurements difficult.

  19. CFD Modeling of Airflow in a Livestock Building

    DEFF Research Database (Denmark)

    Rong, Li; Elhadidi, B.; Khalifa, H. E.

    2010-01-01

    In this paper, a 2D simulation for a typical livestock building is performed to assess the ammonia emission removal rate to the atmosphere. Two geometry models are used and compared in order to represent the slatted floor. In the first model the floor is modeled as a slatted floor and in the second...... the accuracy of the porous jump assumption by comparing the velocity, and ammonia concentration in a 2D simulation, heated solid bodies are added to represent the livestock in the following simulations. The results of simulations with heat source also indicate that modeling the slatted floor with slats...... is necessary. Furthermore, the combination of low inlet velocity and heated objects causes the flow to be buoyancy dominated and unsteady. This unsteadiness can be common in similar buoyancy induced flows for high Rayleigh number flow. The paper concludes with tradeoffs suggested for simulation of livestock...

  20. Hybrid Ventilation in New and Retrofitted Office Buildings

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The scope of this annex is to obtain better knowledge of the use of hybrid ventilation technologies. The annex will focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on development...

  1. Suitability evaluation of multipoint simultaneous CO₂ sampling wireless sensors for livestock buildings.

    Science.gov (United States)

    Calvet, Salvador; Campelo, José Carlos; Estellés, Fernando; Perles, Angel; Mercado, Ricardo; Serrano, Juan José

    2014-06-13

    The environment in livestock buildings must be controlled to ensure the health and welfare of both workers and animals, as well as to restrict the emission of pollutants to the atmosphere. Among the pollutants generated inside these premises, carbon dioxide (CO2) is of great interest in terms of animal welfare and ventilation control. The use of inexpensive sensors means that complete systems can be designed with a number of sensors located around the building. This paper describes a study of the suitability of multipoint simultaneous CO2 sensors operating in a wireless sensor network, which was found to operate satisfactorily under laboratory conditions and was found to be the best alternative for these applications. The sensors showed a highly linear response to CO2 concentrations, ranging from 500 to 5000 ppm. However, individual sensor response was found to differ, which made it necessary to calibrate each one separately. Sensor precision ranged between 80 and 110 ppm CO2, and sensor response to register a 95% change in concentration was estimated at around 5 min. These features mean this type of sensor network can be used to monitor animal welfare and also for environmental control in poorly ventilated livestock premises. According to the tests conducted in this study, a temporal drift may occur and therefore a regular calibration of sensors would be needed.

  2. Suitability Evaluation of Multipoint Simultaneous CO2 Sampling Wireless Sensors for Livestock Buildings

    Directory of Open Access Journals (Sweden)

    Salvador Calvet

    2014-06-01

    Full Text Available The environment in livestock buildings must be controlled to ensure the health and welfare of both workers and animals, as well as to restrict the emission of pollutants to the atmosphere. Among the pollutants generated inside these premises, carbon dioxide (CO2 is of great interest in terms of animal welfare and ventilation control. The use of inexpensive sensors means that complete systems can be designed with a number of sensors located around the building. This paper describes a study of the suitability of multipoint simultaneous CO2 sensors operating in a wireless sensor network, which was found to operate satisfactorily under laboratory conditions and was found to be the best alternative for these applications. The sensors showed a highly linear response to CO2 concentrations, ranging from 500 to 5000 ppm. However, individual sensor response was found to differ, which made it necessary to calibrate each one separately. Sensor precision ranged between 80 and 110 ppm CO2, and sensor response to register a 95% change in concentration was estimated at around 5 min. These features mean this type of sensor network can be used to monitor animal welfare and also for environmental control in poorly ventilated livestock premises. According to the tests conducted in this study, a temporal drift may occur and therefore a regular calibration of sensors would be needed.

  3. Suitability Evaluation of Multipoint Simultaneous CO2 Sampling Wireless Sensors for Livestock Buildings

    Science.gov (United States)

    Calvet, Salvador; Campelo, José Carlos; Estellés, Fernando; Perles, Angel; Mercado, Ricardo; Serrano, Juan José

    2014-01-01

    The environment in livestock buildings must be controlled to ensure the health and welfare of both workers and animals, as well as to restrict the emission of pollutants to the atmosphere. Among the pollutants generated inside these premises, carbon dioxide (CO2) is of great interest in terms of animal welfare and ventilation control. The use of inexpensive sensors means that complete systems can be designed with a number of sensors located around the building. This paper describes a study of the suitability of multipoint simultaneous CO2 sensors operating in a wireless sensor network, which was found to operate satisfactorily under laboratory conditions and was found to be the best alternative for these applications. The sensors showed a highly linear response to CO2 concentrations, ranging from 500 to 5000 ppm. However, individual sensor response was found to differ, which made it necessary to calibrate each one separately. Sensor precision ranged between 80 and 110 ppm CO2, and sensor response to register a 95% change in concentration was estimated at around 5 min. These features mean this type of sensor network can be used to monitor animal welfare and also for environmental control in poorly ventilated livestock premises. According to the tests conducted in this study, a temporal drift may occur and therefore a regular calibration of sensors would be needed. PMID:24932867

  4. Saving energy for ventilation by careful selection of building materials

    DEFF Research Database (Denmark)

    Wargocki, Pawel; Knudsen, Henrik Nellemose

    2008-01-01

    The main objective of the research project described in this paper was to study the potential of reducing energy used for ventilating buildings by using low-polluting building materials without compromising indoor air quality.......The main objective of the research project described in this paper was to study the potential of reducing energy used for ventilating buildings by using low-polluting building materials without compromising indoor air quality....

  5. Wireless data management system for environmental monitoring in livestock buildings

    Directory of Open Access Journals (Sweden)

    James Gray

    2017-03-01

    Full Text Available The impact of air quality on the health, welfare and productivity of livestock needs to be considered, especially when livestock are kept in enclosed buildings. The monitoring of such environmental factors allows for the development of appropriate strategies to reduce detrimental effects of sub-optimal air quality on the respiratory health of both livestock and farmers. In 2009, an environmental monitoring system was designed, developed and tested that allowed for the monitoring of a number of airborne pollutants. One limitation of the system was the manual collection of logged data from each unit. This paper identifies limitations of the current environmental monitoring system and suggests a range of networking technologies that can be used to increase usability. Consideration is taken for the networking of environmental monitoring units, as well as the collection of recorded data. Furthermore, the design and development of a software system that is used to collate and store recorded environmental data from multiple farms is explored. In order to design such a system, simplified software engineering processes and methodologies have been utilised. The main steps taken in order to complete the project were requirements elicitation with clients, requirements analysis, system design, implementation and finally testing. The outcome of the project provided a potential prototype for improving the environmental monitoring system and analysis informing the benefit of the implementation.

  6. Estimation of Airflow in Livestock Buildings using Image Analysis

    DEFF Research Database (Denmark)

    Larsen, Rasmus

    1996-01-01

    of a livestock building, the airflow in a laser-illuminated plane may be visualized. Based on sequences of images recorded of this plane using a video camera, estimates of 2--D flow vectors are derived locally. The local estimates of velocity are found using a set of spatio-temporal convolution filters...... on the image sequence. After which the local estimates are integrated to smooth flow fields using a model that incorporates spatial smoothness. The algorithms are illustrated using a scale model of a pigs sty under isothermic conditions. It should be noted that this is an non-invasive technique (laser...

  7. Computer Simulation of Buildings Cooled by Natural Ventilation.

    Science.gov (United States)

    1983-05-01

    performance of a building, the influence of natural infiltration on mechanical ventilation systems, and the study of smoke in the event of a fire...natural infiltration on mechanical ventilation systems, and the study of smoke in the event of a fire. Unclassified SECURITY CLASSIrIcATION OF TIIS PAGE...whether open or closed). Other influences include the operation of mechanical ventilation systems and the transient effects caused by opening and

  8. Enhanced Single-Sided Ventilation with Overhang in Buildings

    Directory of Open Access Journals (Sweden)

    Jinsoo Park

    2016-02-01

    Full Text Available Enhancing the ventilation performance of energy-efficient buildings with single-sided openings is important because their ventilation performance is poor and strongly depends on the wind conditions. We considered an overhang as a potential building façade for improving the single-sided ventilation performance. We performed numerical simulations of three-dimensional unsteady turbulent flows over an idealized building with an overhang in order to investigate the effect of the overhang on the ventilation performance. Parametric studies were systematically carried out where the overhang length, wind speed, and wind direction were varied. The numerical results showed that the overhang drastically enhanced the ventilation rate in the windward direction regardless of the wind speed. This is because, for windward cases, the overhang produces a vortex with strong flow separation near the tip of the overhang, which promotes a net airflow exchange at the entrance and increases the ventilation rate. However, the ventilation rates for the leeward and side cases are slightly decreased with the overhang. Using an overhang with single-sided ventilation greatly reduces the local mean age of air (LMA in the windward direction but increases it in the leeward direction.

  9. Passive Cooling of buildings by night-time ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, Heinrich; Heiselberg, Per

    Due to an overall trend towards an increasing cooling energy demand in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising concept. However, because of uncertainties in thermal comfort predictions, architects and engineers...... will remain, especially if night-time ventilation is applied in combination with other cooling methods. Building energy simulations showed that the performance of night-time ventilation is also affected by the heat transfer at internal room surfaces, as the cooling effect is very limited for heat transfer...

  10. Livestock

    NARCIS (Netherlands)

    Mottet, Anne; Haan, de Cees; Falcucci, Alessandra; Tempio, Giuseppe; Opio, Carolyn; Gerber, P.J.

    2017-01-01

    Livestock contribute to food security by supplying essential macro- and micro-nutrients, providing manure and draught power, and generating income. But they also consume food edible by humans and graze on pastures that could be used for crop production. Livestock, especially ruminants, are often

  11. Modeling, Estimation and Control of Indoor Climate in Livestock Buildings

    DEFF Research Database (Denmark)

    Wu, Zhuang

    the resilience of the control system to disturbances beyond its bandwidth, increases the manipulators utilization efficiency, and reduces energy consumption by solving a constrained convex optimization. Through comparative simulation results analysis, the proposed modeling and control technique is proved......The main objective of this research is to design an efficient control system for the indoor climate of a large-scale partition-less livestock building, in order to maintain a healthy, comfortable and economically energy consuming indoor environment for the agricultural animals and farmers....... With necessary assumptions and simplifications, the dominant air flow distributions are investigated and the phenomenon of horizontal variations is well depicted. The designed entire control system consists of an outer feedback closed-loop dynamic controller and an inner feed-forward redundancy optimization...

  12. Quantitative relationship of sick building syndrome symptoms with ventilation rates

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Mirer, Anna G.; Mendell, Mark J.

    2009-01-01

    Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence in office workers with ventilation rate. For each study, slopes were calculated, representing the fractional change in SBS symptom prevalence per unit change in ventilation rate per person. Values of ventilation rate, associated with each value of slope, were also calculated. Linear regression equations were fitted to the resulting data points, after weighting by study size. Integration of the slope-ventilation rate equations yielded curves of relative SBS symptom prevalence versus ventilation rate. Based on these analyses, as the ventilation rate drops from 10 to 5 L/s-person, relative SBS symptom prevalence increases approximately 23percent (12percent to 32percent), and as ventilation rate increases from 10 to 25 L/s-person, relative prevalence decreases approximately 29percent (15percent to 42percent). Variations in SBS symptom types, building features, and outdoor air quality may cause the relationship ofSBS symptom prevalence with ventilation rate in specific situations to differ from the average relationship predicted in this paper.

  13. Assessment of Interventions to Improve Air Quality in a Livestock Building.

    Science.gov (United States)

    Anthony, T Renée; Yang, Anthony Y; Peters, Thomas M

    2017-11-20

    This study examined the effectiveness of engineering controls to reduce contaminant concentrations in a swine farrowing room during winter in the U.S. Midwest. Over two winters, changes in air quality were evaluated following installation of a 1700 m3 h-1 (1000 cfm) recirculating ventilation system to provide 5.4 air exchanges per hour. This system incorporated one of two readily available dust control systems, one based on filtration and the other on cyclonic treatment. A second treatment evaluated reductions in carbon dioxide (CO2) associated with replacement of standard, unvented gas-fired heaters with new vented heaters, installed between the two winter test periods. The concentrations of carbon monoxide and hydrogen sulfide were negligible in the test room. Although concentrations of ammonia increased over each winter test period, the increase was unrelated to increased air movement from the new recirculating ventilation system. The dust concentrations were significantly reduced by the ventilation system for both inhalable dust (23% to 44% with filtration, 33% with cyclone) and respirable dust (32% with filtration, 20% with cyclone), significant (p 0.024) for all except respirable dust using the cyclone (p = 0.141). The filtration unit is recommended to improve livestock building air quality because it was more effective than the cyclone unit at reducing respirable dust. Carbon dioxide concentrations were significantly lower with vented heaters (mean = 1400 ppm, SD = 330 ppm) compared to unvented heaters (mean = 2480 ppm, SD = 160 ppm). A 940 ppm reduction in CO2 was attributed to the use of the vented heater, after accounting for differences in outdoor temperatures and animal housing over both test periods. The benefits of readily available technology to significantly reduce concentrations of dust and CO2 demonstrates useful control options to improve air quality in swine buildings. Copyright© by the American Society of Agricultural Engineers.

  14. Investigation of Indoor Climate in a Naturally Ventilated Office Building

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Kalyanova, Olena; Jensen, Rasmus Lund

    2008-01-01

    A measuring program in a naturally ventilated office building in Copenhagen was carried out to document the indoor climate and ventilation system performance during a year. It included a questionnaire regarding the perceived indoor environmental quality and physical measurements of thermal comfort...... to a combination of poor control of solar shading and a very high local heat load that was above the Danish recommendations for naturally ventilated office buildings. Both measured and perceived indoor air quality in the building was in general very high. The measured air flow rates was relatively high due...... to the need for cooling in the office building, while the level of infiltration was quite low indicating an airtight construction....

  15. Efficient ventilation in school buildings. Design guidebook; Ventilation performante dans les ecoles. Guide de conception

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This guidebook aims at giving practical advices for the design of ventilation systems for school buildings in order to maintain air quality levels and energy consumptions conformable with the real needs: 1 - the specific problem of schools (various types of rooms, particular indoor pollutions); 2 - main criteria to consider (air quality and hygiene, hygro-thermal comfort, ventilation efficiency, acoustic comfort, energy mastery); 3 - main existing solutions (simple-flux blow-off or blow-in mechanical ventilation systems, dual-flux systems, air conditioning systems); 4 - choice of an adapted solution (selection criteria, global solution for the school); setting-up and follow-up (rules, training, maintenance). (J.S.)

  16. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Sullivan, Douglas P.; Fisk, William J.

    2010-10-27

    Approximately ten percent of the energy consumed in U.S. commercial buildings is used by HVAC systems to condition outdoor ventilation air. Reducing ventilation rates would be a simple and broadly-applicable energy retrofit option, if practical counter measures were available that maintained acceptable concentrations of indoor-generated air pollutants. The two general categories of countermeasures are: 1) indoor pollutant source control, and 2) air cleaning. Although pollutant source control should be used to the degree possible, source control is complicated by the large number and changing nature of indoor pollutant sources. Particle air cleaning is already routinely applied in commercial buildings. Previous calculations indicate that particle filtration consumes only 10percent to 25percent of the energy that would otherwise be required to achieve an equivalent amount of particle removal with ventilation. If cost-effective air cleaning technologies for volatile organic compounds (VOCs) were also available, outdoor air ventilation rates could be reduced substantially and broadly in the commercial building stock to save energy. The research carried out in this project focuses on developing novel VOC air cleaning technologies needed to enable energy-saving reductions in ventilation rates. The minimum required VOC removal efficiency to counteract a 50percent reduction in ventilation rate for air cleaning systems installed in the HVAC supply airstream is modest (generally 20percent or less).

  17. Thermal Comfort Studies in Naturally Ventilated Buildings in Jakarta, Indonesia

    OpenAIRE

    Karyono, Tri; Sri, Elita; Sulistiawan, Jevi; Triswanti, Yenny

    2015-01-01

    Many thermal comfort studies have been conducted in offices, classrooms and dwellings, but few in public buildings such as cathedrals, museums and markets. A recent thermal comfort study has been conducted in three naturally ventilated (NV) buildings, a cathedral, a museum and a market, in Jakarta, between March and April 2014. There is a curiosity as to whether people doing slightly different activities with slightly different clothing insulation values, in different building types, might ha...

  18. Cooling of the Building Structure by Night-time Ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai

    seen as a promising passive cooling concept. Many successful examples of passively cooled buildings demonstrate the possibility of providing good thermal comfort conditions without the need for energy-intensive air conditioning systems. However, due to uncertainties in the prediction of thermal comfort......, architects and engineers are still hesitant to apply passive cooling techniques. The basic concept of night-time ventilation involves cooling the building structure overnight in order to provide a heat sink during the occupancy period. As this requires a sufficiently high temperature difference between...... the ambient air and the building structure, the efficiency of night cooling is highly sensitive to climatic conditions and hence also to climate warming. In the first part of this PhD study, the potential for passive cooling of buildings by night-time ventilation was evaluated by analysing climatic data...

  19. Quantitative relationship of sick building syndrome symptoms with ventilation rates

    Science.gov (United States)

    Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence in office workers with ventilation rate. For each study, slopes were calculated, representing the fractional...

  20. Improving Stack Effect in Hot Humid Building Interiors with Hybrid Turbine Ventilator(s

    Directory of Open Access Journals (Sweden)

    Rifa Radia Tashkina

    2014-01-01

    Full Text Available Natural ventilation strategies have been applied through the ages to offer thermal comfort. At present, these techniques could be employed as one of the methods to overcome the electric consumption that comes from the burning of disproportionate fossil fuel to operate air conditioners. This air conditioning process is the main contributor of CO2 emissions. This paper focuses on the efficiency of stack ventilation which is one of the natural ventilation strategies, and at the same time attempts to overcome the problem of erratic wind flow and the low indoor/outdoor temperature difference in the hot, humid Malaysian climate. Wind flow and sufficient pressure difference are essential for stack ventilation, and as such the irregularity can be overcome with the use of the Hybrid Turbine Ventilator (HTV which extracts hot air from the interior of the building via the roof level. The extraction of hot air is constant and consistent throughout the day time as long as there is sunlight falling on the solar panel for solar electricity. The aim of this paper is to explore the different HTV strategies and find out which building dimensions is most expected to reduce maximum indoor air temperature of a given room in a real weather condition.

  1. Classification of Mixtures of Odorants from Livestock Buildings by a Sensor Array (an Electronic Tongue)

    OpenAIRE

    Abu-Khalaf, Nawaf; Iversen, Jens J?rgen L?nsmann

    2007-01-01

    An electronic tongue comprising different numbers of electrodes was able to classify test mixtures of key odorants characteristic of bioscrubbers of livestock buildings (n-butyrate, iso-valerate, phenolate, p-cresolate, skatole and ammonium). The classification of model solutions indicates that the electronic tongue has a promising potential as an on- line sensor for characterization of odorants in livestock buildings. Back propagation artificial neural network was used for classification. Th...

  2. Environment Parameters Control Based on Wireless Sensor Network in Livestock Buildings

    OpenAIRE

    Zhang, Yu; Chen, Qiyu; Liu, Guanting; Shen, Weizheng; Wang, Guanlin

    2016-01-01

    The products quality and welfare of animals are closely related to the environment parameters in livestock buildings. A monitoring and control method of environment parameters in livestock buildings based on wireless sensor network is proposed in this paper. Temperature, humidity, light, carbon dioxide concentration, ammonia concentration, and hydrogen sulfide concentration can be monitored in real time by this method. The above six parameters will be adjusted and controlled through WLS algor...

  3. Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S.; Berger, D.; Zuluaga, M.

    2014-07-01

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the 'fresh' air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the 'normal leakage paths through the building envelope' disappear. CARB researchers have found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, and the assumption is that products will perform similarly in the field. Proper application involves matching expected performance at expected building pressures, but there is no guarantee that those conditions will exist consistently in the finished building. This research effort, which included several weeks of building pressure monitoring, sought to provide field validation of system performance. The performance of four substantially different strategies for providing make-up air to apartments was evaluated.

  4. Intelligent Sensor for Autonomous Cleaning in livestock buildings (ISAC) - A challenge in bioenvironmental engineering

    DEFF Research Database (Denmark)

    Strøm, J.S.; Zhang, G.; Blanke, Mogens

    2003-01-01

    Manual cleaning of livestock buildings, using high-pressure water technology, is one of the most tedious and health threatening tasks which is conducted by human labour. The cleaning process itself contributes to deterioration of the working environment due to stirring up dirt, microorganisms...... and water, which is inhaled by the operator. Consequently, the working conditions for personnel who are performing today?s cleaning of livestock buildings are essential to solve. Societies concerned about food safety and livestock welfare are other essential issues on moderns farmers? agenda in the meet...

  5. Evaluation of Ventilation Strategies in New Construction Multifamily Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Maxwell, S. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Berger, D. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States); Zuluaga, M. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-07-01

    In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent. CARB researchers have found that most new high performance, multifamily housing in the Northeast use one of four strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. Product performance data are based on laboratory tests, but there is no guarantee that those conditions will exist consistently in the finished building. In this research project, CARB evaluated the four ventilation strategies in the field to validate system performance.

  6. Thermal Comfort in a Naturally-Ventilated Educational Building

    Directory of Open Access Journals (Sweden)

    David Mwale Ogoli

    2012-11-01

    Full Text Available A comprehensive study of thermal comfort in a naturally ventilated education building (88,000 ft2 in a Chicago suburb will be conducted with 120 student subjects in 2007. This paper discusses some recent trends in worldwide thermal comfort studies and presents a proposal of research for this building through a series of questionnaire tables. Two research methods used inthermal comfort studies are field studies and laboratory experiments in climate-chambers. The various elements that constitute a “comfortable” thermal environment include physical factors (ambient air temperature, mean radiant temperature, air movement and humidity, personal factors(activity and clothing, classifications (gender, age, education, etc. and psychological expectations (knowledge, experience, psychological effect of visual warmth by, say, a fireplace. Comparisons are made using data gathered from Nairobi, Kenya.Keywords: Comfort, temperature, humidity and ventilation

  7. Evaluation of a Natural Ventilation Configuration at a Public Building

    Science.gov (United States)

    Papakonstantinou, K.; Belias, C.; Vlachakis, N.; Statharas, I.

    2007-12-01

    Wind is regarded as the popular passive cooling resource against hot climate in summer. It can transfer heat from human bodies, when the air temperature is lower than the skin temperature. This concept works indoors as well as outdoors. The present paper refers to the numerical simulation of air velocity and temperature concerning single—sided naturally ventilated buildings and more specifically the special case in which air from the external environment is brought inside the building through openings that have the same direction. The paper draws attention to the physical procedures governing air movement during the single—sided natural ventilation. The study presents a mathematical model, implemented in a general computer code, that can provide detailed information on velocity and temperature, prevailing in three-dimensional single—sided ventilated buildings with openings of any geometrical complexity, for given external meteorological conditions. The mathematical model involves the partial differential equations governing flow and heat transfer, in large enclosures. Turbulent flow is simulated and buoyancy effects are taken into account.

  8. Numerical Prediction of Buoyant Air Flow in Livestock Buildings

    DEFF Research Database (Denmark)

    Svidt, Kjeld

    not include the effect of room geometry, obstacles or heat sources. This paper describes the use of Computational Fluid Dynamics to predict air flow patterns and temperature distribution in a ventilated space. Good agreement is found when results of numerical predictions are compared with experimental data....

  9. Exploring Ventilation Efficiency in Poultry Buildings: The Validation of Computational Fluid Dynamics (CFD in a Cross-Mechanically Ventilated Broiler Farm

    Directory of Open Access Journals (Sweden)

    Antonio Hospitaler

    2013-05-01

    Full Text Available Broiler production in modern poultry farms commonly uses mechanical ventilation systems. This mechanical ventilation requires an amount of electric energy and a high level of investment in technology. Nevertheless, broiler production is affected by periodic problems of mortality because of thermal stress, thus being crucial to explore the ventilation efficiency. In this article, we analyze a cross-mechanical ventilation system focusing on air velocity distribution. In this way, two methodologies were used to explore indoor environment in livestock buildings: Computational Fluid Dynamics (CFD simulations and direct measurements for verification and validation (V&V of CFD. In this study, a validation model using a Generalized Linear Model (GLM was conducted to compare these methodologies. The results showed that both methodologies were similar in results: the average of air velocities values were 0.60 ± 0.56 m s−1 for CFD and 0.64 ± 0.54 m s−1 for direct measurements. In conclusion, the air velocity was not affected by the methodology (CFD or direct measurements, and the CFD simulations were therefore validated to analyze indoor environment of poultry farms and its operations. A better knowledge of the indoor environment may contribute to reduce the demand of electric energy, increasing benefits and improving the thermal comfort of broilers.

  10. Summary of best guidelines and validation of CFD modeling in livestock buildings to ensure prediction quality

    DEFF Research Database (Denmark)

    Rong, Li; Nielsen, Peter V.; Bjerg, Bjarne

    2016-01-01

    scale pig barns was simulated to show the procedures of validating a CFD simulation in livestock buildings. After summarizing the guideline and/or best practice for CFD modeling, the authors addressed the issues related to numerical methods and the governing equations, which were limited to RANS models......, simulating domain etc. This information is particularly important for the readers to evaluate the quality of the CFD simulation results.......Computational Fluid Dynamics (CFD) is increasingly used to study airflow around and in livestock buildings, to develop technologies to mitigate emissions and to predict the contaminant dispersion from livestock buildings. In this paper, an example of air flow distribution in a room with two full...

  11. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Directory of Open Access Journals (Sweden)

    Gil-Baez Maite

    2017-01-01

    Full Text Available European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  12. Natural ventilation systems to enhance sustainability in buildings: a review towards zero energy buildings in schools

    Science.gov (United States)

    Gil-Baez, Maite; Barrios-Padura, Ángela; Molina-Huelva, Marta; Chacartegui, Ricardo

    2017-11-01

    European regulations set the condition of Zero Energy Buildings for new buildings since 2020, with an intermediate milestone in 2018 for public buildings, in order to control greenhouse gases emissions control and climate change mitigation. Given that main fraction of energy consumption in buildings operation is due to HVAC systems, advances in its design and operation conditions are required. One key element for energy demand control is passive design of buildings. On this purpose, different recent studies and publications analyse natural ventilation systems potential to provide indoor air quality and comfort conditions minimizing electric power consumption. In these passive systems are of special relevance their capacities as passive cooling systems as well as air renovation systems, especially in high-density occupied spaces. With adequate designs, in warm/mild climates natural ventilation systems can be used along the whole year, maintaining indoor air quality and comfort conditions with small support of other heating/cooling systems. In this paper is analysed the state of the art of natural ventilation systems applied to high density occupied spaces with special focus on school buildings. The paper shows the potential and applicability of these systems for energy savings and discusses main criteria for their adequate integration in school building designs.

  13. Energy and cost associated with ventilating office buildings in a tropical climate

    National Research Council Canada - National Science Library

    Rim, Donghyun; Schiavon, Stefano; Nazaroff, William W

    2015-01-01

    .... This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale...

  14. Thermal comfort and ventilation criteria for low energy residential buildings in building codes

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kurnitski, Jarek; Awbi, Hazim

    2012-01-01

    of the indoor air quality in such buildings. Currently, there are no global guidelines for specifying the indoor thermal environment in such low-energy buildings. The objective of this paper is to analyse the classification of indoor thermal comfort levels and recommended ventilation rates for different low......Indoor environmental quality and energy performance of buildings are becoming more and more important in the design and construction of low energy, passive and zero energy buildings. At the same time, improved insulation and air tightness have the potential to resulting in a deterioration...... energy buildings, and propose a set of indices that would enable better quantification and comparison among low energy buildings. In this study, the building codes and voluntary guidelines have been reviewed on the basis of experience of Finland, UK, Denmark, USA and Germany. The analysis in this paper...

  15. CO2 MONITORING FOR DEMAND CONTROLLED VENTILATION IN COMMERCIAL BUILDINGS

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Sullivan, Douglas P.; Faulkner, David; Eliseeva, Ekaterina

    2010-03-17

    Carbon dioxide (CO{sub 2}) sensors are often deployed in commercial buildings to obtain CO{sub 2} data that are used, in a process called demand-controlled ventilation, to automatically modulate rates of outdoor air ventilation. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. Demand controlled ventilation is most often used in spaces with highly variable and sometime dense occupancy. Reasonably accurate CO{sub 2} measurements are needed for successful demand controlled ventilation; however, prior research has suggested substantial measurement errors. Accordingly, this study evaluated: (a) the accuracy of 208 CO{sub 2} single-location sensors located in 34 commercial buildings, (b) the accuracy of four multi-location CO{sub 2} measurement systems that utilize tubing, valves, and pumps to measure at multiple locations with single CO{sub 2} sensors, and (c) the spatial variability of CO{sub 2} concentrations within meeting rooms. The field studies of the accuracy of single-location CO{sub 2} sensors included multi-concentration calibration checks of 90 sensors in which sensor accuracy was checked at multiple CO{sub 2} concentrations using primary standard calibration gases. From these evaluations, average errors were small, -26 ppm and -9 ppm at 760 and 1010 ppm, respectively; however, the averages of the absolute values of error were 118 ppm (16%) and 138 ppm (14%), at concentrations of 760 and 1010 ppm, respectively. The calibration data are generally well fit by a straight line as indicated by high values of R{sup 2}. The Title 24 standard specifies that sensor error must be certified as no greater than 75 ppm for a period of five years after sensor installation. At 1010 ppm, 40% of sensors had errors greater than {+-}75 ppm and 31% of sensors has errors greater than {+-}100 ppm. At 760 ppm, 47% of sensors had errors greater than {+-}75 ppm and 37% of

  16. Energy saving technologies of the decentralized ventilation of buildings

    Science.gov (United States)

    Mansurov, R. Sh; Rafalskaya, T. A.

    2017-11-01

    The growing aspiration to energy saving and efficiency of energy leads to necessity to build tight enough buildings. As a result of this the quantity of infiltration air appears insufficient for realization of necessary air exchange in. One of decisions of the given problem is development and application for ventilation of premises of the decentralized forced-air and exhaust systems (DFAES) with recuperative or regenerative heat-exchangers. For an estimation of efficiency of DFAES following basic parameters have been certain: factor of energy saving; factor of efficiency of energy; factor of a heat transfer; factor of an effective utilization of a surface of heat exchange. Were estimated temperature of forced air; actual speed of an air jet on an entrance in a served zone; actual noise level; the charge of external air. Tests of DFAES were spent in natural conditions at which DFAES influenced all set of factors both an external climate, and an internal microclimate of a premise, and also the arrangement on a wind side or behind wind side of a building, influence of surrounding building, fluctuation of temperature of external air is considered. Proceeding from results and the analysis of the lead researches recommendations have been developed for development and manufacture of new sample of DFAES.

  17. Solar chimney: A sustainable approach for ventilation and building space conditioning

    Directory of Open Access Journals (Sweden)

    Lal, S.,

    2013-03-01

    Full Text Available The residential and commercial buildings demand increase with rapidly growing population. It leads to the vertical growth of the buildings and needs proper ventilation and day-lighting. The natural air ventilation system is not significantly works in conventional structure, so fans and air conditioners are mandatory to meet the proper ventilation and space conditioning. Globally building sector consumed largest energy and utmost consumed in heating, ventilation and space conditioning. This load can be reduced by application of solar chimney and integrated approaches in buildings for heating, ventilation and space conditioning. It is a sustainable approach for these applications in buildings. The authors are reviewed the concept, various method of evaluation, modelings and performance of solar chimney variables, applications and integrated approaches.

  18. Design guidelines for natural ventilation systems in tertiary sector buildings

    OpenAIRE

    Van Moeseke, Geoffrey; Bruyère, Isabelle; De Herde, André; CISBAT 2005: Renewables in a changing climate

    2005-01-01

    Parameters determining efficiency of natural ventilation systems are numerous. The most important are architecture and system design. This article get onto both but focuses on system design. Through dynamic simulations it shows that natural ventilation management has a large impact on energy saving but most of all on thermal comfort. Natural ventilation techniques are also weighted against hybrid solutions and high efficiency mechanical cooling solutions. Natural ventilation techniques show t...

  19. Classification of Mixtures of Odorants from Livestock Buildings by a Sensor Array (an Electronic Tongue

    Directory of Open Access Journals (Sweden)

    Jens Jørgen Lønsmann Iversen

    2007-01-01

    Full Text Available An electronic tongue comprising different numbers of electrodes was able to classify test mixtures of key odorants characteristic of bioscrubbers of livestock buildings (n-butyrate, iso-valerate, phenolate, p-cresolate, skatole and ammonium. The classification of model solutions indicates that the electronic tongue has a promising potential as an on- line sensor for characterization of odorants in livestock buildings. Back propagation artificial neural network was used for classification. The average classification rate was above 80% in all cases. A limited, but sufficient number of electrodes were selected by average classification rate and relative entropy. The sufficient number of electrodes decreased standard deviation and relative standard deviation compared to the full electrode array.

  20. Classification of Mixtures of Odorants from Livestock Buildings by a Sensor Array (an Electronic Tongue)

    Science.gov (United States)

    Abu-Khalaf, Nawaf; Iversen, Jens Jørgen Lønsmann

    2007-01-01

    An electronic tongue comprising different numbers of electrodes was able to classify test mixtures of key odorants characteristic of bioscrubbers of livestock buildings (n-butyrate, iso-valerate, phenolate, p-cresolate, skatole and ammonium). The classification of model solutions indicates that the electronic tongue has a promising potential as an online sensor for characterization of odorants in livestock buildings. Back propagation artificial neural network was used for classification. The average classification rate was above 80% in all cases. A limited, but sufficient number of electrodes were selected by average classification rate and relative entropy. The sufficient number of electrodes decreased standard deviation and relative standard deviation compared to the full electrode array.

  1. A novel system solution for cooling and ventilation in office buildings

    DEFF Research Database (Denmark)

    Yu, Tao; Heiselberg, Per Kvols; Lei, Bo

    2015-01-01

    technologies and renewable energy sources have risen. Based on a literature review of natural ventilation, building thermal mass activation and diffuse ceiling ventilation, this paper proposes a new system solution combining these three technologies for cooling and ventilation in office buildings. This new......As a response to new energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need both in summer and in winter. In order to effectively save energy, new interests in cooling concepts using passive cooling...

  2. Comparison of mixing and displacement ventilation in a low energy office building during heating season

    DEFF Research Database (Denmark)

    Fang, Lei; Olesen, Bjarne W.; Wu, Xiaozhou

    2014-01-01

    ventilation compared to those for displacement ventilation. Due to the heat emission from equipments and occupants, heating system was not needed in the low energy office building in a mild winter. In such a situation, indoor thermal environment was still acceptable in terms of the general thermal comfort......The present study investigated the performance of mixing and displacement ventilation systems in a low energy office building during heating season. Measurements were performed with regard to air distribution and ventilation effectiveness. The results show that indoor air temperatures in occupied...

  3. Natural ventilation in high-rise buildings with double facades, saving or waste of energy

    Energy Technology Data Exchange (ETDEWEB)

    Pasquay, T. [Schmidt Reuter Partner , Engineering Co., Research and Development, Koln (Germany)

    2004-04-01

    Double facades are built to allow natural ventilation in high-rise buildings and buildings with high outside noise levels. To evaluate the energetic performance, three buildings with double facades were monitored for at least a year (Siemens building in Dortmund, Victoria Insurance Company in Dusseldorf and RWE Tower in Essen). In one building all the air conditioning facilities had been removed and the facade replaced by a double facade, one building had cooling equipment without mechanical ventilation (concrete core tempered ceiling) and one building had cooling equipment combined with mechanical ventilation. The results document the indoor climate, the boundary conditions for further planning and the possibilities for high-rise buildings with no or only limited cooling facilities. The research was carried out at the University of Dortmund and founded by the state of Nordrhein-Westfahlen (AG-Solar). (author)

  4. Natural ventilation in high-rise buildings with double facades, saving or waste of energy?

    Energy Technology Data Exchange (ETDEWEB)

    Pasquay, T. [Schmidt Reuter Partner, Engineering Company, Research and Development, Koeln (Germany)

    2004-07-01

    Double facades are built to allow natural ventilation in high-rise buildings and buildings with high outside noise levels. To evaluate the energetic performance, three buildings with double facades were monitored for at least one year (Siemens building in Dortmund, Victoria Insurance Company in Duesseldorf and RWE Tower in Essen, all in Germany). In one building all the air conditioning facilities had been removed and the facade replaced by a double facade, one building had cooling equipment without mechanical ventilation (concrete core tempered ceiling) and one building had cooling equipment combined with mechanical ventilation. The results document the indoor climate, the boundary conditions for further planning and the possibilities for high-rise buildings with no or only limited cooling facilities. The research was carried out at the University of Dortmund and founded by the state of Nordrhein-Westfahlen (AG-Solar). (author)

  5. Economic, Environmental and Health Implications of Enhanced Ventilation in Office Buildings.

    Science.gov (United States)

    MacNaughton, Piers; Pegues, James; Satish, Usha; Santanam, Suresh; Spengler, John; Allen, Joseph

    2015-11-18

    Current building ventilation standards are based on acceptable minimums. Three decades of research demonstrates the human health benefits of increased ventilation above these minimums. Recent research also shows the benefits on human decision-making performance in office workers, which translates to increased productivity. However, adoption of enhanced ventilation strategies is lagging. We sought to evaluate two of the perceived potential barriers to more widespread adoption-Economic and environmental costs. We estimated the energy consumption and associated per building occupant costs for office buildings in seven U.S. cities, representing different climate zones for three ventilation scenarios (standard practice (20 cfm/person), 30% enhanced ventilation, and 40 cfm/person) and four different heating, ventilation and air conditioning (HVAC) system strategies (Variable Air Volume (VAV) with reheat and a Fan Coil Unit (FCU), both with and without an energy recovery ventilator). We also estimated emissions of greenhouse gases associated with this increased energy usage, and, for comparison, converted this to the equivalent number of vehicles using greenhouse gas equivalencies. Lastly, we paired results from our previous research on cognitive function and ventilation with labor statistics to estimate the economic benefit of increased productivity associated with increasing ventilation rates. Doubling the ventilation rate from the American Society of Heating, Refrigeration and Air-Conditioning Engineers minimum cost less than $40 per person per year in all climate zones investigated. Using an energy recovery ventilation system significantly reduced energy costs, and in some scenarios led to a net savings. At the highest ventilation rate, adding an ERV essentially neutralized the environmental impact of enhanced ventilation (0.03 additional cars on the road per building across all cities). The same change in ventilation improved the performance of workers by 8

  6. Quantification of the association of ventilation rates with sick building syndrome symptoms

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Mirer, Anna G.; Mendell, Mark J.

    2009-06-01

    Data from published studies were combined and analyzed to develop best-fit equations and curves quantifying the change in sick building syndrome (SBS) symptom prevalence with ventilation rate. For each study, slopes were calculated, representing the fractional change in SBS symptom prevalence per unit change in ventilation rate per person. Values of ventilation rate, associated with each value of slope, were also calculated. Linear regression equations were fit to the resulting data points, after weighting by study size. Integration of the slope-ventilation rate equations yielded curves of relative SBS symptom prevalence versus ventilation rate. Based on these analyses, relative SBS symptom prevalence increases approximately 23percent (12percent to 32percent) as the ventilation rate drops from 10 to 5 L/s-person and relative prevalence decreases approximately 29percent (15percent to 42percent) as ventilation rate increases from 10 to 25 L/s-person.

  7. Assessment of Natural Ventilation Potential for Residential Buildings across Different Climate Zones in Australia

    Directory of Open Access Journals (Sweden)

    Zijing Tan

    2017-09-01

    Full Text Available In this study, the natural ventilation potential of residential buildings was numerically investigated based on a typical single-story house in the three most populous climate zones in Australia. Simulations using the commercial simulation software TRNSYS (Transient System Simulation Tool were performed for all seasons in three representative cities, i.e., Darwin for the hot humid summer and warm winter zone, Sydney for the mild temperate zone, and Melbourne for the cool temperate zone. A natural ventilation control strategy was generated by the rule-based decision-tree method based on the local climates. Natural ventilation hour (NVH and satisfied natural ventilation hour (SNVH were employed to evaluate the potential of natural ventilation in each city considering local climate and local indoor thermal comfort requirements, respectively. The numerical results revealed that natural ventilation potential was related to the local climate. The greatest natural ventilation potential for the case study building was observed in Darwin with an annual 4141 SNVH out of 4728 NVH, while the least natural ventilation potential was found in the Melbourne case. Moreover, summer and transition seasons (spring and autumn were found to be the optimal periods to sustain indoor thermal comfort by utilising natural ventilation in Sydney and Melbourne. By contrast, natural ventilation was found applicable over the whole year in Darwin. In addition, the indoor operative temperature results demonstrated that indoor thermal comfort can be maintained only by utilising natural ventilation for all cases during the whole year, except for the non-natural ventilation periods in summer in Darwin and winter in Melbourne. These findings could improve the understanding of natural ventilation potential in different climates, and are beneficial for the climate-conscious design of residential buildings in Australia.

  8. [Sanitary and epidemiological evaluation of the ventilation and air-conditioning systems of public buildings].

    Science.gov (United States)

    Dvorianov, V V

    2012-01-01

    The microbial contamination of ventilation and air conditioning systems was examined in the administrative buildings. The author proposes a set of indicators, methods for determining the scope of investigations, as well as sampling tactics and criteria for evaluating the microbial contamination of the ventilation and air-conditioning systems. The content of yeasts and molds in the delivered air has been found to be of importance for evaluating the sanitary-and epidemiological state of ventilation systems.

  9. Integrated Solution in an Office Room with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    An integrated system is proposed in this study to combine diffuse ceiling ventilation with a thermally activated building construction (TABS), aiming to provide cooling/ heating and ventilation to an office room all year around. The performance of the integrated system is evaluated by full...

  10. Experimental and Numerical Analysis of Wind Driven Natural Ventilation in a Building Scale Model

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; True, Jan Per Jensen; Sandberg, Mats

    2004-01-01

    Airflow through openings in a cross ventilated building scale model was investigated in a wind tunnel and by numerical predictions. Predictions for a wind direction perpendicular to the building showed an airflow pattern consisting of streamlines entering the room, that originated from approximat......Airflow through openings in a cross ventilated building scale model was investigated in a wind tunnel and by numerical predictions. Predictions for a wind direction perpendicular to the building showed an airflow pattern consisting of streamlines entering the room, that originated from...... and leeward sides and the airflow rate was found to be a linear function of the local pressure difference across the building....

  11. Ventilation, temperature, and HVAC characteristics in small and medium commercial buildings in California.

    Science.gov (United States)

    Bennett, D H; Fisk, W; Apte, M G; Wu, X; Trout, A; Faulkner, D; Sullivan, D

    2012-08-01

    This field study of 37 small and medium commercial buildings throughout California obtained information on ventilation rate, temperature, and heating, ventilating, and air-conditioning (HVAC) system characteristics. The study included seven retail establishments; five restaurants; eight offices; two each of gas stations, hair salons, healthcare facilities, grocery stores, dental offices, and fitness centers; and five other buildings. Fourteen (38%) of the buildings either could not or did not provide outdoor air through the HVAC system. The air exchange rate averaged 1.6 (s.d. = 1.7) exchanges per hour and was similar between buildings with and without outdoor air supplied through the HVAC system, indicating that some buildings have significant leakage or ventilation through open windows and doors. Not all buildings had sufficient air exchange to meet ASHRAE 62.1 Standards, including buildings used for fitness centers, hair salons, offices, and retail establishments. The majority of the time, buildings were within the ASHRAE temperature comfort range. Offices were frequently overcooled in the summer. All of the buildings had filters, but over half the buildings had a filter with a minimum efficiency reporting value rating of 4 or lower, which are not very effective for removing fine particles. Most U.S. commercial buildings (96%) are small- to medium-sized, using nearly 18% of the country's energy, and sheltering a large population daily. Little is known about the ventilation systems in these buildings. This study found a wide variety of ventilation conditions, with many buildings failing to meet relevant ventilation standards. Regulators may want to consider implementing more complete building inspections at commissioning and point of sale. © 2012 John Wiley & Sons A/S.

  12. Multivariate analysis comparing microbial air content of an air-conditioned building and a naturally ventilated building over one year

    Science.gov (United States)

    Parat, Sylvie; Perdrix, Alain; Fricker-Hidalgo, Hélène; Saude, Isabelle; Grillot, Renee; Baconnier, Pierre

    Heating, ventilation and air-conditioning (HVAC) may be responsible for the production and spread of airborne microorganisms in office buildings. In order to compare airborne microbiological flora in an air-conditioned building with that in a naturally ventilated building, eight sets of measurements were made over a 1-year period. Concurrently with other environmental measurements, air samples were collected in each building, from three offices and from the outdoor air, using the Andersen single-stage sampler. Three different media were used to culture fungi, staphylococci and mesophilic bacteria. Multivariate analysis revealed a group of offices more contaminated than others, and a marked seasonal variation in fungal concentrations. A comparison of mean levels of microorganisms measured in the two buildings showed that the air microbial content was significantly higher and more variable in the naturally ventilated building than in the air-conditioned building. Moreover, in the naturally ventilated building, the interior fungal content was strongly dependent on the outdoor content, while in the air-conditioned building fungal concentrations remained constant despite significant variations measured outside. This was confirmed by a statistical comparison of the correlation coefficients between indoor and outdoor concentrations. No difference was observed regarding gaseous pollutants and temperature, but relative humidity was significantly higher in the air-conditioned building. The effect of HVAC was to prevent the intake of outdoor particles and to dilute the indoor concentrations. These results are consistent with the presence of high-efficiency filters and a steam humidifier in the HVAC system under study.

  13. Power Efficiency of Systems Applied for Heating Building and Structure External Walls with Ventilated Air Spaces

    OpenAIRE

    I. F. Fialko; A. S. Statsenko

    2009-01-01

    The paper considers power-efficient systems applied for heating building and structure external walls with ventilated air spaces and prescribes directions and problems pertaining to power-efficiency improvement of such systems.

  14. Use of VOC sensors for air quality control of building ventilation systems

    National Research Council Canada - National Science Library

    M Großklos

    2015-01-01

    .... An air quality control was developed and tested in four single-family passive house dwellings to control the building ventilation system via VOC sensors and a special adaptation algorithm to handle...

  15. Building America Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts, Tyler, Texas

    Energy Technology Data Exchange (ETDEWEB)

    2015-08-01

    ?Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy.

  16. An Evaluation of a Proposed Ventilation System for Melbourne's CH2 Building

    Directory of Open Access Journals (Sweden)

    Lu Aye

    2012-11-01

    Full Text Available The understanding of ventilation requirements in commercial buildings has been significantly revised in the last 10-15 years. A link between health, productivity and increased fresh air use has been established by some research and this understanding underpins the ventilation philosophy adopted for the CH2 building. The ventilation system design for CH2 that has been evaluated in this paper envisages a mechanically driven system during the day, using the displacement technique to distribute filtered air. All introduced air will be drawn from outside and no recycling of air will occur. Natural ventilation will be employed at night using the stack effect, enhanced by turbine ventilators. This paper critiques the proposed ventilation system in the light of international experience and the particular conditions of the building's location. The evidence suggests that natural ventilation sometimes may be inadequate to achieve the desired objectives. Minimization of indoor pollutants, adequate filtration and high levels of ventilation should, however, ensure satisfactory air quality during occupied hours.

  17. Change-over natural and mechanical ventilation system energy consumption in single-family buildings

    Science.gov (United States)

    Kostka, Maria; Szulgowska-Zgrzywa, Małgorzata

    2017-11-01

    The parameters of the outside air in Poland cause that in winter it is reasonable to use a mechanical ventilation equipped with a heat recovery exchanger. The time of spring, autumn, summer evenings and nights are often characterized by the parameters of the air, which allow for a natural ventilation and reduce the electricity consumption. The article presents the possibilities of energy consumption reduction for three energy standards of buildings located in Poland, ventilated by a change-over hybrid system. The analysis was prepared on the assumption that the air-to-water heat pump is the heat source for the buildings.

  18. Suite Ventilation Characteristics of Current Canadian Mid-andHigh-Rise Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wray, Craig P.

    2000-01-01

    This paper characterizes ventilation in residential suiteslocated in ll buildings were between six and thirty-two stories tall andwere built between 1990 and 1995. The key findings from field performancetests of these buildings were: 1. Corridor supply airflows usually didnot meet design flows.2. Makeup air paths for suite exhaust were notproperly designed.3. Suite access door leakage was highly variable andusually did not meet smoke control requirements.4. Airflow from thecorridor through the suite access door leakage appeared to be the primaryventilation air supply for suites.5. Suites were usually well-ventilated,but some were marginally- or under-ventilated.6. Poor pressure controloften allowed transfer air from one suite to another. Inter-suitetransfer air fractions ranged from 0 to 45 percent, with an average of 19percent. In summary, this work showed suite ventilation can be highlyinfluenced by corridor supply flows, by the treatment of corridor accessdoors, and by transfer airflows. As a result, suite ventilation at anygiven time in current mid- and high-rise residential buildings is verydifficult to predict. To ensure suite ventilation performs as intendedunder all operating conditions, the building industry needs to addressthe identified problems through improved ventilation design, operation,and maintenance practices.

  19. Climatic potential for passive cooling of buildings by night-time ventilation in Europe

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, H.; Heiselberg, Per

    2006-01-01

    , Eastern and Northern Europe. The basic concept involves cooling the building structure overnight in order to provide a heat sink that is available during the occupancy period. In this study, the potential for passive cooling of buildings by night-time ventilation was evaluated by analysing climatic data......Due to an overall trend towards less heating and more cooling demands in buildings in many European countries over the last few decades, passive cooling by night-time ventilation is seen as a promising technique, particularly for commercial buildings in the moderate or cold climates of Central...

  20. Summarized Data of Test Space Heating, Ventilation and Air Conditioning Inspections from the Building Assessment Survey and Evaluation Study

    Science.gov (United States)

    Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues

  1. Supply Ventilation and Prevention of Carbon Monoxide (II) Ingress into Building Premises

    Science.gov (United States)

    Litvinova, N. A.

    2017-11-01

    The article contains the relationships of carbon monoxide (II) concentration versus height-above-ground near buildings derived based on results of studies. The results of studies are crucial in preventing external pollutants ingress into a ventilation system. Being generated by external emission sources, such as motor vehicles and city heating plants, carbon monoxide (II) enters the premises during operation of a supply ventilation system. Fresh air nomographic charts were drawn to select the height of a fresh air intake into the ventilation system. Nomographic charts take into account external sources. The selected emission sources are located at various levels above ground relative to the building. The recommendations allow designing supply ventilation taking into account the quality of ambient air through the whole building height.

  2. THE SOLUTION TO THE PROBLEM OF USING GROUND WATER TO COOL LIVESTOCK BUILDINGS

    Directory of Open Access Journals (Sweden)

    Thay Ngok Shon

    2017-01-01

    Full Text Available Ambient temperature in the central part of Vietnam in summer can reach 32–35°C; in some places it can be more than 42°C. Hot climate strongly affects the animal organism alongside with the animal weight reduction and reduction the quantity of egg-laying in poultry. Therefore, air conditioning in livestock buildings is necessary. There are several ways to cool the temperature in such buildings, and each one has its own advantages and disadvantages. We propose to use underground water at the temperature of 24–25°C for this purpose. One of the methods of cooling sheds for livestock is sprinkler irrigation of water on the roof. For calculating the amount of heat, removed from the indoor air in the shed to the cooling water, in the first approximation specialists believe in some cases that an appropriate amount of heat being removed is determined mainly by heat transfer from the air inside the shed to the cooling water through the surface of the roof, represented by the lower part of the wave that form the surface of a metal tile, neglecting the influence of heat conduction on top of the wave of the tile surface. Consequentially, such a simplification leads to possible errors. Therefore, the authors solved the problem of cooling shed by irrigation of water on the roof by an analytical method. Specifically, we solved the problem of heat conductivity of the fin of the finite length of constant cross section, wherein different sides of the fin are conjugate with different environments. Additionally, the calculation considered the effect of solar radiation. For this purpose, the authors have created a heat balance equation at steady state for any infinitesimal element of the fin, and solved the differential equation afterwards. The authors applied the results for calculating practical problem of ground water irrigation of a roof of a livestock shed made of metal areas tiles. 

  3. Ventilation systems for multi-unit residential buildings : performance requirements and alternative approaches

    Energy Technology Data Exchange (ETDEWEB)

    Hill, D.

    2003-09-01

    A growing proportion of housing in Canada consists of multi-unit residential buildings (MURBs). Ventilation strategies have not changed much over the past three decades. Research conducted by Canada Mortgage and Housing Corporation (CMHC) and others has shown that conventional ventilation strategies consume significant amounts of energy, are noisy, consume internal floor area, and can become conduits for pests and smoke. As a result, a research project was initiated to develop performance requirements and alternative approaches for ventilation systems in MURBs. The issues to be addressed by alternative ventilation systems were identified through literature review. The various codes and standards applicable to ventilation capacities for apartments in MURBs in Canada were evaluated. It was revealed that the ventilation system airflow rates required for any given apartment and the amount of ventilation that should be provided by infiltration varies greatly depending on the codes or standards selected. The performance parameters that were identified in this paper were: ventilation performance, capital and operating costs, maintenance, fire and smoke control, noise issues, comfort, system issues, and owner and designer construction issues. The following four different alternative ventilation systems were discussed: (1) passive vents with suite-based mechanical exhaust, (2) balanced individual suites with heat recovery (HRV) units, (3) balanced floor-by-floor systems with heat recovery, and (4) balanced central systems with heat recovery. Further testing and assessment is needed before these proposed systems can enter the marketable phase. More research is also needed into the characterization of stack and wind pressures in MURBs. 5 tabs.

  4. Ventilated buildings optimisation by using a coupled thermal-airflow simulation program

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2011-01-01

    This work shows the optimization of natural ventilation within buildings at the stage of design and behaviour of the occupants. An evaluation is done by coupled multizone air modelling and thermal building simulation by using a deterministic set of input factors comprising among others climate, l...

  5. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    The application of a ventilation system in a new building is a multidimensional complex problem that involves quantifiable and non-quantifiable data like energy consump¬tion, indoor environment, building integration and architectural expression. This paper presents a structured method for evaluat...

  6. Model for Naturally Ventilated Cavities on the Exteriors of Opaque Building Thermal Envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Griffith, B.

    2006-11-01

    This paper describes a model for naturally ventilated cavities on the exterior of opaque building thermal envelopes that are formed by the presence of a lightweight baffle. The model can be used for building components that are slightly detached from the main envelope (but do not connect to the interior).

  7. Parameter study on performance of building cooling by night-time ventilation

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, H.; Heiselberg, Per

    2008-01-01

    of different parameters such as building construction, heat gains, air change rates, heat transfer coefficients and climatic conditions including annual variations on the number of overheating degree hours (operative room temperature >26 °C) was evaluated. Climatic conditions and air flow rate during night......Especially for commercial buildings in moderate climates, night-time ventilation seems to be a simple and energy-efficient approach to improve thermal comfort in summer. However, due to uncertainties in the prediction of thermal comfort in buildings with night-time ventilation, architects...... and engineers are still hesitant to apply this technique. In order to reduce the uncertainties, the most important parameters affecting night ventilation performance need to be identified. A typical office room was therefore modelled using a building energy simulation programme (HELIOS), and the effect...

  8. The effect of using low-polluting building materials on ventilation requirements and energy use in buildings

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Frontczak, M. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-07-01

    The main objective of the ongoing research project described in this paper was to study the potential for reducing energy used for ventilating buildings by using low-polluting building materials, without compromising the indoor air quality. To quantify this potential, the exposure-response relationships, i.e. the relationships between ventilation rate and perceived indoor air quality, were established for rooms furnished with different categories of polluting materials and the simulations of energy used for ventilation were carried out. The exposure-response relationships were based on a summary of data reported in the literature on exposure-response relationships for materials tested in laboratory settings in small-scale glass chambers, and in full-scale in climate chambers, test rooms or normal offices. New experiments were also considered in which the effect of using low-polluting materials on perceived air quality was examined in test rooms ventilated with different outdoor air supply rates, low-polluting materials being selected in small glass chambers. The results suggest that the exposure-response relationships vary between different building materials and that the perceived air quality can be improved considerably when polluting building materials are substituted with materials that pollute less. The preliminary energy simulations indicate that selecting low-polluting materials will result in considerable energy savings as a result of reducing the ventilation rates required to achieve acceptable indoor air quality. (au)

  9. An overview of the TA-55, Building PF-4 ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-02-22

    An overview of the TA-55, Building PF-4 ventilation system is provided in the following sections. Included are descriptions of the zone configurations, equipment-performance criteria, ventilation support systems, and the ventilation-system evaluation criteria. Section 4.2.1.1 provides a brief discussion of the ventilation system function. Section 4.2.1.2 provides details on the overall system configuration. Details of system interfaces and support systems are provided in Section 4.2.1.3. Section 4.2.1.4 describes instrumentation and control needed to operate the ventilation system. Finally, Sections 4.2.1.5 and 4.2.1.6 describe system surveillance/maintenance and Technical Safety Requirements (TSR) Limitations, respectively. Note that the numerical parameters included in this description are considered nominal; set points and other specifications actually fall within operational bands.

  10. Assessment of Pollutant Spread from a Building Basement with three Ventilation Systems

    CERN Document Server

    Koffi, Juslin

    2010-01-01

    Ventilation aims at providing a sufficient air renewal for ensuring a good indoor air quality (IAQ), yet building energy policies are leading to adapting various ventilation strategies minimising energy losses through air renewal. A recent IAQ evaluation campaign in French dwellings shows important pollution of living spaces by VOCs such as formaldehyde, acetaldehyde or hexanal, particularly in buildings equipped with a garage. Besides, radon emission from soil is a subject of concern in many countries. Several studies are done to understand its release mode and deal with the spread of this carcinogen gas. This paper aims to experimentally assess a contaminant spread from a house basement using mechanical exhaust and balanced ventilation systems, and natural ventilation.

  11. Ammonia and methane emissions from two naturally ventilated dairy cattle buildings and the influence of climatic factors on ammonia emissions

    Science.gov (United States)

    Wu, Wentao; Zhang, Guoqiang; Kai, Peter

    2012-12-01

    Based on the requirement of the international conventions, there is a pressing need for inventory of NH3, CH4, CO2 and N2O emissions from livestock buildings. The main aim of this study was to quantify the gas emissions and investigate the influence of the climatic factors on ammonia emissions. The measurements were carried out in two naturally ventilated dairy cattle buildings with different layouts, floor types and manure management systems during three periods covering winter and summer time. Air temperature and the three dimensional air velocities inside and outside the buildings were recorded over the course of summer period. Emission rates were determined by CO2 production model. The results showed that the internal concentrations of NH3, CH4 and CO2 were increased or decreased simultaneously. Low concentration of N2O was measured outside and inside the buildings; the difference of the concentrations were also very low. The variation of CH4 and CO2 concentrations showed a strong correlation. The NH3 emission rates varied from 32 to 77 g HPU-1 d-1 in building 1 and varied from 18 to 30 g HPU-1 d-1 in building 2. The average emission of CH4 was 290 and 230 g HPU-1 d-1 from building 1 and 2, respectively. Diurnal pattern was found for NH3 and CH4 emission rates. From multiple linear regression models, there was a significant linear relationship between NH3 emission rates and climatic factors including the external wind speed as well as the air temperature (P 0.05).

  12. Solar ventilation: The use of solar chimneys for natural ventilation of buildings

    NARCIS (Netherlands)

    Macquoy, B.

    2011-01-01

    This paper is written for the TIDO-course AR0532 Smart & Bioclimatic Design Theory. A very old principle is the system of the solar chimney for ventilation, which in recent years has regained interests. This essay will explore the potentials of solar chimneys in a modern application.

  13. Appropriate Ventilation Solutions for the Iconographic Buildings from the Fifties

    DEFF Research Database (Denmark)

    Vestergaard, Inge; Blyt, Henrik

    2016-01-01

    . The paper concludes that interdisciplinary ways of working will improve both architecture and preservation and comfort, and that higher value hereby is created. Furthermore the new initiatives from the industry are shown, which indicates a movement towards innovation of decentralized ventilation solutions....

  14. Energy and cost associated with ventilating office buildings in a tropical climate.

    Directory of Open Access Journals (Sweden)

    Donghyun Rim

    Full Text Available Providing sufficient amounts of outdoor air to occupants is a critical building function for supporting occupant health, well-being and productivity. In tropical climates, high ventilation rates require substantial amounts of energy to cool and dehumidify supply air. This study evaluates the energy consumption and associated cost for thermally conditioning outdoor air provided for building ventilation in tropical climates, considering Singapore as an example locale. We investigated the influence on energy consumption and cost of the following factors: outdoor air temperature and humidity, ventilation rate (L/s per person, indoor air temperature and humidity, air conditioning system coefficient of performance (COP, and cost of electricity. Results show that dehumidification of outdoor air accounts for more than 80% of the energy needed for building ventilation in Singapore's tropical climate. Improved system performance and/or a small increase in the indoor temperature set point would permit relatively large ventilation rates (such as 25 L/s per person at modest or no cost increment. Overall, even in a thermally demanding tropical climate, the energy cost associated with increasing ventilation rate up to 25 L/s per person is less than 1% of the wages of an office worker in an advanced economy like Singapore's. This result implies that the benefits of increasing outdoor air ventilation rate up to 25 L/s per person--which is suggested to provide for productivity increases, lower sick building syndrome symptom prevalence, and reduced sick leave--can be much larger than the incremental cost of ventilation.

  15. A First Approach to Natural Thermoventilation of Residential Buildings through Ventilation Chimneys Supplied by Solar Ponds

    OpenAIRE

    Ferdinando Salata; Chiara Alippi; Anna Tarsitano; Iacopo Golasi; Massimo Coppi

    2015-01-01

    The exploitation of natural ventilation is a good solution to improve buildings from an energetic point of view and to fulfill the requirements demanded by the thermohygrometric comfort and the air quality in enclosed spaces. Some past researches demonstrated how some devices, useful to this purpose, follow the principles of solar chimneys and are able to move air masses while exploiting the Archimedes thrust. The natural ventilation must be supplied by a flow moving upward, generated by a he...

  16. Demand Controlled Ventilation and Classroom Ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-05-01

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  17. Demand controlled ventilation and classroom ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Davies, Molly [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Eliseeva, Ekaterina [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Faulkner, David [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Hong, Tienzen [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-01-06

    This document summarizes a research effort on demand controlled ventilation and classroom ventilation. The research on demand controlled ventilation included field studies and building energy modeling.

  18. Development of mechanical ventilation system with low energy consumption for renovation of buildings

    DEFF Research Database (Denmark)

    Terkildsen, Søren

    in reducing CO2-emmissions. Over the last decade, initiatives have been taken to reduce its energy consumption e.g. by the European Union, national governments or NGOs. The initiatives have mostly focused on improving the thermal properties of the building envelope to reduce heat losses. Building services......A general reduction in total energy consumption is needed, due to the increasing concerns about climate change caused by CO2-emmissions from fossil fuels. In 2004, the building sector accounted for 40% of the total energy consumption in the EU and the US and therefore must play a crucial role......, including ventilation, therefore now represent a larger part of the total energy consumption. Mechanical ventilation has been the most widely used principle of ventilation over the last 50 years, but the conventional system design needs revising to meet future energy requirements. The increase in the use...

  19. Computational Analysis of Natural Ventilation Flows in Geodesic Dome Building in Hot Climates

    Directory of Open Access Journals (Sweden)

    Zohreh Soleimani

    2016-08-01

    Full Text Available For centuries, dome roofs were used in traditional houses in hot regions such as the Middle East and Mediterranean basin due to its thermal advantages, structural benefits and availability of construction materials. This article presents the computational modelling of the wind- and buoyancy-induced ventilation in a geodesic dome building in a hot climate. The airflow and temperature distributions and ventilation flow rates were predicted using Computational Fluid Dynamics (CFD. The three-dimensional Reynolds-Averaged Navier-Stokes (RANS equations were solved using the CFD tool ANSYS FLUENT15. The standard k-epsilon was used as turbulence model. The modelling was verified using grid sensitivity and flux balance analysis. In order to validate the modelling method used in the current study, additional simulation of a similar domed-roof building was conducted for comparison. For wind-induced ventilation, the dome building was modelled with upper roof vents. For buoyancy-induced ventilation, the geometry was modelled with roof vents and also with two windows open in the lower level. The results showed that using the upper roof openings as a natural ventilation strategy during winter periods is advantageous and could reduce the indoor temperature and also introduce fresh air. The results also revealed that natural ventilation using roof vents cannot satisfy thermal requirements during hot summer periods and complementary cooling solutions should be considered. The analysis showed that buoyancy-induced ventilation model can still generate air movement inside the building during periods with no or very low wind.

  20. On the thermal interaction of building structure and heating and ventilation system

    Science.gov (United States)

    Hensen, Joannes Laurentius Maria

    Developments in the field of building performance evaluation tools for thermal interaction of building structure and heating and ventilating systems are described. The technique employed is computer simulation of the integrated dynamic system comprising the occupants, the building and its heating and ventilating system. Assessment criteria from a literature review in thermal comfort to examine acceptable fluctuations in indoor climate are defined. Building and plant energy simulation within the context of Computer Aided Building Design (CABD) is described. An exisiting energy simulation environment ESP(R) (Environmental Systems Performance (Research version)) is chosen. A fluid flow network simulation module is described. Extensions to ESP(R) to predict the dynamic behavior of the heating and ventilation system are described. The coupling of fluid flow, plant side energy and mass, and building side energy simulation into one integrated program is described. A multistage verification and validation methodology is demonstrated by examples addressing each successive step. Imaginary and real world cases are described to demonstrate application of the study in a modeling orientated and a building engineering context.

  1. Combining a building simulation with energy systems analysis to assess the benefits of natural ventilation

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2013-01-01

    a thermal air flow simulation program - Into the energy systems analysis model. Descriptions of the energy systems in two geographical locations, i.e. Mexico and Denmark, are set up as inputs. Then, the assessment is done by calculating the energy impacts as well as environmental benefits in the energy......This article shows the combination of a thermal air flow simulation program with an energy systems analysis model in order to assess the use of natural ventilation as a method for saving energy within residential buildings in large-scale scenarios. The aim is to show the benefits for utilizing...... natural airflow instead of active systems such as mechanical ventilation or air-conditioning in buildings where the indoor temperature is over the upper limit of the comfort range. The combination is done by introducing the energy saving output - calculated with a model of natural ventilation using...

  2. Experimental Study of an Integrated System with Diffuse Ceiling Ventilation and Thermally Activated Building Constructions

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per

    The experiments are carried out in a climate chamber located at the Department of Civil Engineering Aalborg University. The objective of the experiments is to evaluate the performance of the system combining diffuse ceiling ventilation and thermally activated building construction (TABS) in terms...

  3. Breathing architecture: Conceptual architectural design based on the investigation into the natural ventilation of buildings

    Directory of Open Access Journals (Sweden)

    Anastasia D. Stavridou

    2015-06-01

    Full Text Available This study explores architectural design by examining air, fluid mechanics, and the natural ventilation of buildings. In this context, this research introduces a new way of dealing with the process of architectural synthesis. The proposed way can be used either to create new architectural projects or to rethink existing ones. This study is supported by previous investigation into the natural ventilation of buildings via computational and laboratory simulation (Stavridou, 2011; Stavridou and Prinos, 2013. The investigation into the natural ventilation of buildings provides information and data that affect architectural design through various parameters. The parameters of architectural synthesis that are influenced and discussed in this paper are the following: (i inspiration and analogical transfer, (ii initial conception of the main idea using computational fluid dynamics (digital design, (iii development of the main idea through an investigatory process toward building form optimization, and (iv form configuration, shape investigation, and other morphogenetic prospects. This study illustrates the effect of natural ventilation research on architectural design and thus produces a new approach to the architectural design process. This approach leads to an innovative kind of architecture called “breathing architecture.”

  4. Reduced energy use for ventilation of buildings through selection of low-polluting building materials and furniture. Final Report; Reduceret energiforbrug til ventilation af bygninger hvori der systematisk er valgt lav-forurenende materialer og inventar. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    2007-11-15

    The main objective of the research project was to study the potential of reducing energy used for ventilating buildings by using low-polluting building materials and thereby ensuring that indoor air quality will not be compromised. To quantify this potential, the exposure-response relationships, i.e. the relationships between ventilation rate and the perceived indoor air quality (indoor air quality perceived by humans as opposed to indoor air quality evaluated by chemical measurements), were established for rooms furnished with different more or less polluting materials. Based on these results simulations of energy used for ventilation were carried out for selected building scenarios. The exposure-response relationships were established by summarizing existing data reported in the literature and by a series of new experiments. The data summarized by reviewing the literature included data for building materials and furnishing tested in a laboratory setting in small-scale ventilated glass chambers, and in full-scale in ventilated climate chambers, test rooms or normal offices. Relevant low-polluting building materials were selected based on the literature review and a series of new experiments performed in ventilated small-scale glass chambers. Then the final experiments in which the effects of using low-polluting materials on perceived air quality were carried out in ventilated small-scale glass chambers and in full-scale test rooms ventilated with different outdoor air supply rates. Simulations of energy used for ventilation were carried out using BSim software. During simulations the ventilation rate was varied to obtain different levels of air quality when low-polluting building materials had been used, and it was examined how these changes influence the energy use. The results show that the exposure-response relationships vary between different building materials and thus the ventilation requirement to achieve a certain level of perceived indoor air quality vary

  5. Air ventilation impacts of the "wall effect" resulting from the alignment of high-rise buildings

    Science.gov (United States)

    Yim, S. H. L.; Fung, J. C. H.; Lau, A. K. H.; Kot, S. C.

    The objective of this study is to investigate the air ventilation impacts of the so called "wall effect" caused by the alignment of high-rise buildings in complex building clusters. The research method employs the numerical algorithm of computational fluid dynamics (CFD - FLUENT) to simulate the steady-state wind field in a typical Hong Kong urban setting and investigate pollutant dispersion inside the street canyon utilizing a pollutant transport model. The model settings of validation study were accomplished by comparing the simulation wind field around a single building block to wind tunnel data. The results revealed that our model simulation is fairly close to the wind tunnel measurements. In this paper, a typical dense building distribution in Hong Kong with 2 incident wind directions (0° and 22.5°) is studied. Two performance indicators are used to quantify the air ventilation impacts, namely the velocity ratio ( VR) and the retention time ( T r) of pollutants at the street level. The results indicated that the velocity ratio at 2 m above ground was reduced 40% and retention time of pollutants increased 80% inside the street canyon when high-rise buildings with 4 times height of the street canyon were aligned as a "wall" upstream. While this reduction of air ventilation was anticipated, the magnitude is significant and this result clearly has important implications for building and urban planning.

  6. Effect of using low-polluting building materials and increasing ventilation on perceived indoor air quality

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Zuczek, P. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-07-01

    The potential of improving perceived air quality indoors was quantified when low-polluting materials are used and when building ventilation is increased. This was done by studying the relationships between ventilation rate and the perceived indoor air quality. A sensory panel assessed the air quality in test rooms ventilated with realistic outdoor air supply rates, where combinations of high- and low-polluting wall, floor and ceiling materials were set up. These materials were ranked as high- and low-polluting using sensory assessments of air quality in small-scale glass chambers, where they were tested individually. Substituting materials ranked as high-polluting with materials ranked as lower-polluting improved the perceived air quality in the test rooms. This improvement was greater than what was achieved by a realistic increase of the ventilation rate in the test rooms. Thus reducing pollution emitted from building materials that affects the perceived air quality has a considerable potential of limiting the energy for ventilation without compromising indoor air quality. (au)

  7. Energy and IAQ Implications of Alternative Minimum Ventilation Rates in California Retail and School Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Dutton, Spencer M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-01

    For a stand-alone retail building, a primary school, and a secondary school in each of the 16 California climate zones, the EnergyPlus building energy simulation model was used to estimate how minimum mechanical ventilation rates (VRs) affect energy use and indoor air concentrations of an indoor-generated contaminant. The modeling indicates large changes in heating energy use, but only moderate changes in total building energy use, as minimum VRs in the retail building are changed. For example, predicted state-wide heating energy consumption in the retail building decreases by more than 50% and total building energy consumption decreases by approximately 10% as the minimum VR decreases from the Title 24 requirement to no mechanical ventilation. The primary and secondary schools have notably higher internal heat gains than in the retail building models, resulting in significantly reduced demand for heating. The school heating energy use was correspondingly less sensitive to changes in the minimum VR. The modeling indicates that minimum VRs influence HVAC energy and total energy use in schools by only a few percent. For both the retail building and the school buildings, minimum VRs substantially affected the predicted annual-average indoor concentrations of an indoor generated contaminant, with larger effects in schools. The shape of the curves relating contaminant concentrations with VRs illustrate the importance of avoiding particularly low VRs.

  8. Thermal comfort in naturally ventilated buildings in Maceio, Brazil

    Science.gov (United States)

    Djamila, Harimi

    2017-11-01

    This article presents the results from thermal comfort survey carried out in classrooms over two different seasons in Maceio, Brazil. The secondary data were collected from thermal comfort field study conducted in naturally ventilated classrooms. Objective and subjective parameters were explored to evaluate thermal comfort conditions. The potential effect of air movement on subjects' vote under neutrality was evaluated. Overall, the indoor climate of the surveyed location was classified warm and humid. Conflicting results were depicted when analyzing the effect of air movements on subjects' vote. The mean air temperature for subjects feeling hot was found to be lower than those feeling warm. A reasonable approach to tackle these two unpredictable results was suggested. Correlation matrix between selected thermal comfort variables was developed. Globe temperature recorded the highest correlation with subjects' response on ASHRAE seven-point scale. The correlation was significant at the 0.01 level. On the other hand, the correlation between air movement and subjects' response on ASHRAE seven-point scale was weak but significant. Further field studies on the current topic were recommended.

  9. Experimental and Numerical Studies of Solar Chimney for Ventilation in Low Energy Buildings

    DEFF Research Database (Denmark)

    Zha, Xinyu; Zhang, Jun; Qin, Menghao

    2017-01-01

    As an effective way to protect environment and save energy in buildings, passive ventilation method has generated intense interest for improving indoor thermal environment in recent years. Among these passive ventilation solutions, design of solar chimney in buildings is a promising approach...... the performance of a full-scale solar chimney in a real building in East-ern China. The measured performance is compared with theoretical calculation and numerical simulation. In a solar chimney of 6.2m length, 2.8m width and 0.35m air gap, the experimental results show that air flow rate of 70.6 m3/h~1887.6 m3/h...... can be achieved during the daytime in the testing day. Comparing measured value with theoretical value, the flow rate is generally lower than the theoretical value. By data analysis, the suggested discharge coefficient Cd of solar energy in real engineering project is 0.51. With the use...

  10. Prediction of Indoor Airflow Patterns in Livestock Buildings Ventilated through a Diffuse Ceiling

    DEFF Research Database (Denmark)

    Jacobsen, L.; Nielsen, Peter Vilhelm; Morsing, S.

    2004-01-01

    The airflow conditions in an experimental pig housing unit are examined both experimentally and numerically (simulation) with particular focus on the airflow conditions in the occupational zone of the animals. Two heating setups are used, and the temperature is measured in a horizontal profile at...... at the floor and at the ceiling. Good concordances between the measurements and the simulations are reached at the floor level. At the ceiling level, the conformity to the measuring results is unsatisfactory...

  11. Cost optimization for buildings with hybrid ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Kun; Lu, Yan

    2018-02-13

    A method including: computing a total cost for a first zone in a building, wherein the total cost is equal to an actual energy cost of the first zone plus a thermal discomfort cost of the first zone; and heuristically optimizing the total cost to identify temperature setpoints for a mechanical heating/cooling system and a start time and an end time of the mechanical heating/cooling system, based on external weather data and occupancy data of the first zone.

  12. A First Approach to Natural Thermoventilation of Residential Buildings through Ventilation Chimneys Supplied by Solar Ponds

    Directory of Open Access Journals (Sweden)

    Ferdinando Salata

    2015-07-01

    Full Text Available The exploitation of natural ventilation is a good solution to improve buildings from an energetic point of view and to fulfill the requirements demanded by the thermohygrometric comfort and the air quality in enclosed spaces. Some past researches demonstrated how some devices, useful to this purpose, follow the principles of solar chimneys and are able to move air masses while exploiting the Archimedes thrust. The natural ventilation must be supplied by a flow moving upward, generated by a heat source performing at temperatures slightly higher than the one present in the environment. To have a minimum energetic effect, the heat can be extracted from solar ponds; solar ponds are able to collect and store solar energy in the geographical regions characterized by sufficient values of solar radiation. Thus it is possible, in summer, to provoke a nocturnal natural ventilation useful for the air change in indoor spaces (in those climatic areas where, during the night, there is a temperature gradient.

  13. Enhancement of Fire Safety of an Existing Green Building due to Natural Ventilation

    Directory of Open Access Journals (Sweden)

    Hong Sheng Huang

    2016-03-01

    Full Text Available In recent years, natural ventilation technology is extensively used in order to improve indoor environment quality and reduce power consumption of air-conditioning systems in green buildings. However, the effect of natural ventilation on fires needs to be evaluated carefully, and how to make these energy-saving buildings safe is a topic worth studying. This study uses Fire Dynamics Simulator on some fire safety enhancement measures for an existing green building without installation of a smoke exhaust system. Since the building is located on a school campus, it does not require a smoke exhaust system according to Taiwan fire regulations. Referential results, obtained after a series of improvement strategies are tested, show that kiln natural ventilation can generate a comfortable air flow. Unfortunately, due to the stack effect, hot air and fatal smoke are blown into the evacuation route area behind the room when a fire occurs. The findings showed that there are two feasible improvement measures, “controlling the off state of each air inlet” and “setting up an exhaust port in the rear of room”, which can effectively resolve the fire safety issues; the construction of which can be undertaken at a reasonable cost.

  14. Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings

    DEFF Research Database (Denmark)

    Hummelgarrd, John; Juhl, Peter; Sæbjörnsson, Kristian

    2005-01-01

    The indoor air quality and occupant satisfaction was studied in five mechanically ventilated and four naturally ventilated open-plan office buildings in Copenhagen, using a simplified assessment procedure. Temperature and the concentration of CO2 were monitored in 2-10 locations per office...... on the same day within that week. The study indicated that occupants in naturally ventilated offices have a lower prevalence of symptoms than those in mechanically ventilated offices. Although the room air temperature varied more and the concentration of CO2 was higher in the naturally ventilated offices...... the results showed that the occupants' satisfaction with the indoor environment was higher in naturally ventilated than in mechanically ventilated offices....

  15. Airtightness and ventilation system performance of apartments in new multi-unit residential buildings

    Energy Technology Data Exchange (ETDEWEB)

    Cooke, G. [Air Solutions Inc., Toronto, ON (Canada); Kokko, J.; Greene, T. [Enermodal Engineering Ltd., Kitchener, ON (Canada)

    2005-07-01

    There are growing concerns that conventional air handling systems in apartment buildings cannot ventilate individual apartments, are expensive in terms of initial cost and maintenance, have little impact on indoor air quality, and negatively impact the integrity of fire and smoke control separations. This paper discusses the strategy of compartmentalizing individual apartments to eliminate uncontrolled air movement as well as providing efficient and effective ventilation in each suite. The findings of recent air leakage testing and ventilation system performance testing in several recently constructed high-rise buildings were documented in this paper. Results indicated that compartmentalization was a viable strategy. However, ventilation strategies for both common corridors and apartments required adjustments. Air leakage testing showed that individual apartments were relatively airtight. However, concerns were raised that continuous negative pressure could induce water leakage through the building envelope. Testing also discovered that airflow capacities of in-suite exhaust equipment was less than manufacturer's specifications. Duct lengths, diameters, fittings, elbows and termination details had an impact on airflow performance. Testing also confirmed that the corridor ventilation systems were not energy efficient as a significant amount of outdoor air was required to pressurize leaks in the corridors and to ensure sufficient air was available to make-up air requirements in each apartment in response to intermittent exhaust fan operation. It was also determined that a very small positive pressure was required to accomplish the task of pressurizing corridors to minimize odour transmission. The provision of weather-stripping on corridor to apartment doors would reduce the quantity of airflow required for pressurization, helping to prevent shifts in pressure due to opening doors, elevators and wind and stack pressures acting in varying ways. 8 refs., 4 tabs., 2

  16. Augmenting natural ventilation using solar heat and free cool energy for residential buildings

    Directory of Open Access Journals (Sweden)

    N. B. Geetha

    2014-03-01

    Full Text Available In many urban buildings ventilation is not sufficient that will increase the temperature and also create unhealthy atmosphere inside the room. In such buildings artificially induced ventilation through freely available energy promote comfort conditions by reducing the temperature by 2 to 3°C and also creating good circulation of fresh air inside the room. In the present work the concept of improving the ventilation by excess hot energy available during summer days from the solar flat plate collector and by storing cool energy available during the early morning hour in the Phase Change Material (PCM based storage system is attempted. An experimental setup is made to study the effect of improvement in natural ventilation and the results are reported. A visible reduction in temperature is observed through circulation of air from the bottom side of the room to the roof of the house using the stored hot and cool energy. A CFD analysis is also carried out using ANSYS-CFX software to simulate and evaluate the mass flow of air at the inlet and at the selected RTD location by matching the transient temperature profile of the simulated result with the experimental results at the selected RTD location.

  17. Natural ventilation - A new method based on the Walton model applied to cross-ventilated buildings having two large external openings

    OpenAIRE

    Bastide, Alain; Allard, Francis; Boyer, Harry

    2007-01-01

    International audience; In order to provide comfort in a low energy consumption building, it is preferable to use natural ventilation rather than HVAC systems. To achieve this, engineers need tools that predict the heat and mass transfers between the building's interior and exterior. This article presents a method implemented in some building software, and the results are compared to CFD. The results show that the knowledge model is not sufficiently well-described to identify all the physical...

  18. A Prospective Study of Ventilation Rates and Illness Absence in California Office Buildings

    Energy Technology Data Exchange (ETDEWEB)

    Eliseeva, Ekaterina A. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Spears, Michael [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sullivan, Douglas P. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-10-07

    Background – This study investigated the associations of ventilation rates (VRs), estimated from indoor CO2 concentrations, in offices with the amount of respiratory infections, illness absences, and building-related health symptoms in occupants. Methods – Office buildings were recruited from three California climate zones. In one or more study spaces within each building, real-time logging sensors measured carbon dioxide, temperature, and relative humidity for one year. Ventilation rates were estimated using daily peak CO2 levels, and also using an alternative metric. Data on occupants and health outcomes were collected through web-based surveys every three months. Multivariate models were used to assess relationships between metrics of ventilation rate or CO2 and occupant outcomes. For all outcomes, negative associations were hypothesized with VR metrics, and positive associations with CO2 metrics. Results – Difficulty recruiting buildings and low survey response limited sample size and study power. In 16 studied spaces within 9 office buildings, VRs were uniformly high over the year, from twice to over nine times the California office VR standard (7 L/s or 15 cfm per person). VR and CO2 metrics had no statistically significant relationships with occupant outcomes, except for a small significantly positive association of the alternative VR metric with respiratory illness-related absence, contrary to hypotheses. Conclusions– The very high time-averaged VRs in the California office buildings studied presumably resulted from “economizer cycles” bringing in large volumes of outdoor air; however, in almost all buildings even the estimated minimum VRs supplied (without the economizer) substantially exceeded the minimum required VR. These high VRs may explain the absence of hypothesized relationships with occupant outcomes. Among uniformly high VRs, little variation in contaminant concentration and occupant effects would be expected. These findings may

  19. Cost benefit analysis of the night-time ventilative cooling in office building

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli; Fisk, William J.; Faulkner, David

    2003-06-01

    The indoor temperature can be controlled with different levels of accuracy depending on the building and its HVAC system. The purpose of this study was to evaluate the potential productivity benefits of improved temperature control, and to apply the information for a cost-benefit analyses of night-time ventilative cooling, which is a very energy efficient method of reducing indoor daytime temperatures. We analyzed the literature relating work performance with temperature, and found a general decrement in work performance when temperatures exceeded those associated with thermal neutrality. These studies included physiological modelling, performance of various tasks in laboratory experiments and measured productivity at work in real buildings. The studies indicate an average 2% decrement in work performance per degree C temperature rise, when the temperature is above 25 C. When we use this relationship to evaluate night-time ventilative cooling, the resulting benefit to cost ratio varies from 32 to 120.

  20. Ventilation Relevant Contaminants of Concern in Commercial Buildings Screening Process and Results

    Energy Technology Data Exchange (ETDEWEB)

    Parthasarathy, Srinandini [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); McKone, Thomas E. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States); Apte, Michael G. [Lawrence Berkeley National Laboratory (LBNL), Berkeley, CA (United States)

    2011-04-29

    This report summarizes the screening procedure and its results for selecting contaminants of concern (COC), whose concentrations are affected by ventilation in commercial buildings. Many pollutants comprising criteria pollutants, volatile organic compounds (VOCs), semi-volatile organic compounds (SVOCs) and biological contaminants are found in commercial buildings. In this report, we focus primarily on identifying potential volatile organic COC, which are impacted by ventilation. In the future we plan to extend this effort to inorganic gases and particles. Our screening considers compounds detected frequently in indoor air and compares the concentrations to health-guidelines and thresholds. However, given the range of buildings under consideration, the contaminant sources and their concentrations will vary depending on the activity and use of the buildings. We used a literature review to identify a large list of chemicals found in commercial-building indoor air. The VOCs selected were subject to a two stage screening process, and the compounds of greater interest are included in priority List A. Other VOCs that have been detected in commercial buildings are included in priority List B. The compounds in List B, were further classified into groups B1, B2, B3, B4 in order of decreasing interest.

  1. Assessment of buildings with ventilated facade systems and evaluation of point thermal bridges

    OpenAIRE

    Šadauskienė, Jolanta; Šeduikytė, Lina; Juozas RAMANAUSKAS; Buska, Andrius

    2017-01-01

    Analyzes of influence of the point thermal bridges of buildings with ventilated facade systems on the thermal properties of envelops are presented in the paper. The relation between the separate components of the envelop were made: thermal properties and thickness of supporting wall's layer; value of thermal conductivity and thickness of insulation layer. Studies have shown, that the value of the point thermal transmittance, which depended on the thermal properties of the envelop and thicknes...

  2. Hybrid ventilation in residential buildings – the proposal of research for the Polish climatic conditions

    Directory of Open Access Journals (Sweden)

    Kostka Maria

    2017-01-01

    Full Text Available Due to the geographic location and the influence of the polar maritime and polar continental air masses we observe a large variety and variability of external air parameters in Poland. Both during the whole year and also in shorter, even several-day periods. The parameters of outside air indicate that combination of mechanical and natural ventilation in detached buildings can be cost-effective and allows keeping the thermal comfort and good indoor air quality.

  3. Assessment of Natural Ventilation Potential for Residential Buildings across Different Climate Zones in Australia

    OpenAIRE

    Zijing Tan; Xiang Deng

    2017-01-01

    In this study, the natural ventilation potential of residential buildings was numerically investigated based on a typical single-story house in the three most populous climate zones in Australia. Simulations using the commercial simulation software TRNSYS (Transient System Simulation Tool) were performed for all seasons in three representative cities, i.e., Darwin for the hot humid summer and warm winter zone, Sydney for the mild temperate zone, and Melbourne for the cool temperate zone. A na...

  4. Use of VOC sensors for air quality control of building ventilation systems

    OpenAIRE

    Großklos, M.

    2015-01-01

    Air quality control with VOC (volatile organic compound) sensors in residential buildings could increase user comfort by adapting to the actual contaminant level. Preliminary tests assessed the dynamics of VOC levels in single-family passive houses with a ventilation system. At normal and exceptional usages, sufficient signal variations were measured for air quality control. An air quality control was developed and tested in four single-family passive house dwellings to cont...

  5. The integration of engineering and architecture: A perspective on natural ventilation for the new San Francisco Federal Building

    Energy Technology Data Exchange (ETDEWEB)

    McConahey, Erin; Haves, Philip; Christ, Tim

    2002-05-31

    A description of the in-progress design of a new Federal Office Building for San Francisco is used to illustrate a number of issues arising in the design of large, naturally ventilated office buildings. These issues include the need for an integrated approach to design involving the architects, mechanical and structural engineers, lighting designers and specialist simulation modelers. In particular, the use of natural ventilation, and the avoidance of air-conditioning, depends on the high degree of exposed thermal mass made possible by the structural scheme and by the minimization of solar heat gains while maintaining the good daylighting that results from optimization of the fagade. Another issue was the need for a radical change in interior space planning in order to enhance the natural ventilation; all the individual enclosed offices are located along the central spine of each floorplate rather than at the perimeter. The role of integration in deterring the undermining of the design through value engineering is discussed. The comfort criteria for the building were established based on the recent extension to the ASHRAE comfort standard based on the adaptive model for naturally ventilated buildings. The building energy simulation program EnergyPlus was used to compare the performance of different natural ventilation strategies. The results indicate that, in the San Francisco climate, wind-driven ventilation provides sufficient nocturnal cooling to maintain comfortable conditions and that external chimneys do not provide significant additional ventilation at times when it when it would be beneficial.

  6. Impact of ventilation systems and energy savings in a building on the mechanisms governing the indoor radon activity concentration.

    Science.gov (United States)

    Collignan, Bernard; Powaga, Emilie

    2017-11-23

    For a given radon potential in the ground and a given building, the parameters affecting the indoor radon activity concentration (IRnAC) are indoor depressurization of a building and its air change rate. These parameters depend mainly on the building characteristics, such as airtightness, and on the nature and performances of the ventilation system. This study involves a numerical sensitivity assessment of the indoor environmental conditions on the IRnAC in buildings. A numerical ventilation model has been adapted to take into account the effects of variations in the indoor environmental conditions (depressurization and air change rate) on the radon entry rate and on the IRnAC. In the context of the development of a policy to reduce energy consumption in a building, the results obtained showed that IRnAC could be strongly affected by variations in the air permeability of the building associated with the ventilation regime. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Indoor air quality in mechanically ventilated residential dwellings/low-rise buildings: A review of existing information

    DEFF Research Database (Denmark)

    Aganovic, Amar; Hamon, Mathieu; Kolarik, Jakub

    Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review of the e......Mechanical ventilation has become a mandatory requirement in multiple European standards addressing indoor air quality (IAQ) and ventilation in residential dwellings (single family houses and low-rise apartment buildings). This article presents the state of the art study through a review...... concentrations. The authors additionally noted that the literature frequently reported the role of improper maintenance and use on deterioration of IAQ in residential dwellings. The summarized data and comments may provide useful information for future guidelines related to ventilation strategies designed...

  8. A Model for Air Flow in Ventilated Cavities Implemented in a Tool for Whole-Building Hygrothermal Analysis

    DEFF Research Database (Denmark)

    Grau, Karl; Rode, Carsten

    2006-01-01

    A model for calculating air flows in ventilated cavities has been implemented in the whole-building hygrothermal simulation tool BSim. The tool is able to predict indoor humidity conditions using a transient model for the moisture conditions in the building envelope.......A model for calculating air flows in ventilated cavities has been implemented in the whole-building hygrothermal simulation tool BSim. The tool is able to predict indoor humidity conditions using a transient model for the moisture conditions in the building envelope....

  9. CAN SORBENT-BASED GAS PHASE AIR CLEANING FOR VOCS SUBSTITUTE FOR VENTILATION IN COMMERCIAL BUILDINGS?

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William; Fisk, William J.

    2007-08-01

    This paper reviews current knowledge about the suitability of sorbent-based air cleaning for removing volatile organic compounds (VOCs) from the air in commercial buildings, as needed to enable reductions in ventilation rates and associated energy savings. The principles of sorbent air cleaning are introduced, criteria are suggested for sorbent systems that can counteract indoor VOC concentration increases from reduced ventilation, major findings from research on sorbent performance for this application are summarized, and related priority research needs are identified. Major conclusions include: sorbent systems can remove a broad range of VOCs with moderate to high efficiency, sorbent technologies perform effectively when challenged with VOCs at the low concentrations present indoors, and there is a large uncertainty about the lifetime and associated costs of sorbent air cleaning systems when used in commercial buildings for indoor VOC control. Suggested priority research includes: experiments to determine sorbent system VOC removal efficiencies and lifetimes considering the broad range and low concentration of VOCs indoors; evaluations of in-situ regeneration of sorbents; and an updated analysis of the cost of sorbent air cleaning relative to the cost of ventilation.

  10. Energy Performance of a Novel System Combining Natural Ventilation with Diffuse Ceiling Inlet and Thermally Activated Building Systems (TABS)

    DEFF Research Database (Denmark)

    Yu, Tao

    As a response to new stringent energy policies in the building sector, office buildings have become well-insulated and highly-airtight, resulting in an increasing cooling need in both summer and winter. This study proposes a novel system combining natural ventilation with diffuse ceiling inlet...... and thermally activated building systems (TABS) for cooling and ventilation in future Danish office buildings. The new solution would have the special potential of using natural ventilation all year round even in the extremely cold seasons without any draught risk. The main focuses of this study are the energy...... saving potential and the steady-state and dynamic energy performance of this system. The presented work utilizes building simulation method to investigate the energy saving potential of this novel system. Afterwards, an experimental set-up is built in the laboratory to simulate a real office environment...

  11. Airborne Particulate Matter in Two Multi-Family Green Buildings: Concentrations and Effect of Ventilation and Occupant Behavior

    Directory of Open Access Journals (Sweden)

    Allison P. Patton

    2016-01-01

    Full Text Available There are limited data on air quality parameters, including airborne particulate matter (PM in residential green buildings, which are increasing in prevalence. Exposure to PM is associated with cardiovascular and pulmonary diseases, and since Americans spend almost 90% of their time indoors, residential exposures may substantially contribute to overall airborne PM exposure. Our objectives were to: (1 measure various PM fractions longitudinally in apartments in multi-family green buildings with natural (Building E and mechanical (Building L ventilation; (2 compare indoor and outdoor PM mass concentrations and their ratios (I/O in these buildings, taking into account the effects of occupant behavior; and (3 evaluate the effect of green building designs and operations on indoor PM. We evaluated effects of ventilation, occupant behaviors, and overall building design on PM mass concentrations and I/O. Median PMTOTAL was higher in Building E (56 µg/m3 than in Building L (37 µg/m3; I/O was higher in Building E (1.3–2.0 than in Building L (0.5–0.8 for all particle size fractions. Our data show that the building design and occupant behaviors that either produce or dilute indoor PM (e.g., ventilation systems, combustion sources, and window operation are important factors affecting residents’ exposure to PM in residential green buildings.

  12. Composition and distribution of particulate matter (PM10) in a mechanically ventilated University building

    Science.gov (United States)

    Ali, Mohamed Yasreen Mohamed; Hanafiah, Marlia Mohd; Latif, Mohd Talib

    2016-11-01

    This study analyses the composition and distribution of particulate matter (PM10) in the Biology department building, in UKM. PM10 were collected using SENSIDYNE Gillian GilAir-5 Personal Air Sampling System, a low-volume sampler, whereas the concentration of heavy metals was determined using Inductively coupled plasma-mass spectrometry (ICP-MS). The concentration of PM10 recorded in the mechanically ventilated building ranges from 89 µgm-3 to 910 µgm-3. The composition of the selected heavy metals in PM10 were dominated by zinc, followed by copper, lead and cadmium. It was found that the present of indoor-related particulate matter were originated from the poorly maintained ventilation system, the activity of occupants and typical office equipments such as printers and photocopy machines. The haze event occured during sampling periods was also affected the PM10 concentration in the building. This results can serve as a starting point to assess the potential human health damage using the life cycle impact assessment, expressed in term of disability adjusted life year (DALY).

  13. Thermal Comfort and Ventilation Criteria for low Energy Residential Buildings in Building Codes

    DEFF Research Database (Denmark)

    Cao, Guangyu; Kurnitski, Jarek; Awbi, Hazim

    2012-01-01

    Indoor environmental quality and energy performance of buildings are becoming more and more important in the design and construction of low energy, passive and zero energy buildings. At the same time, improved insulation and air tightness have the potential to resulting in a deterioration of the ...

  14. Air movement preferences observed in naturally ventilated buildings in humid subtropical climate zone in China.

    Science.gov (United States)

    Yang, Wei; Zhang, Guoqiang

    2009-11-01

    Occupants' preferences for air movement in naturally ventilated buildings have been extracted from a database of three thermal comfort surveys conducted in the humid subtropical climate zone in China, during winter, spring, and summer seasons. The distribution of draft sensation shows that only 25.7, 38.5, and 28.7% of the subjects in winter, spring, and summer, respectively, felt that the available air movement was just right, suggesting that indoor air velocity may be a big problem in naturally ventilated buildings in humid subtropical China. Air movement preferences show that 15.8, 61.3, and 80.6% of subjects in winter, spring, and summer, respectively, wanted more air movement. Only a handful of subjects wanted less air movement than they were actually experiencing in any season, suggesting that draft was not much of an issue for thermal comfort. Occupants' preference for air movement is strongly related to thermal sensation, showing that people want to control air movement as a means of improving their comfort. The demand for less air movement under cool sensation is much smaller than the overwhelming demand for more air movement when the sensation was warm. The above results indicate that air movement might have a significant influence over the respondents' comfort sensation and that people required a high level of air movement in order to be comfortable during the summer season. Thus, one efficient way to improve the thermal environment in summer in humid subtropical China could be to provide occupants with effective natural ventilation and allow personal control of the air movement. Our findings are also applicable to other buildings, to encourage designers to provide air movement as a low energy cooling strategy and to ensure that sufficient levels of air movement are available.

  15. Possible User-Dependent CFD Predictions of Transitional Flow in Building Ventilation

    DEFF Research Database (Denmark)

    Peng, Lei; Nielsen, Peter Vilhelm; Wang, Xiaoxue

    2016-01-01

    among different teams. It indicates that the combined effects of a lack of general turbulence model, and possible errors in multiple decisions based on users’ experience may have caused the observed significant difference. Prediction of transitional flows, as often observed in building ventilation......, is shown to be still a very challenging task. This calls for a solid approach of validation and uncertainty assessment in CFD “experiments”. The users are recommended to follow an existing guideline of uncertainty assessment of CFD predictions to minimize the errors and uncertainties in the future....

  16. Partial pit exhaust improves indoor air quality and effectiveness of air cleaning in livestock housing

    DEFF Research Database (Denmark)

    Zhang, Guoqiang; Bjerg, B.; Zong, C.

    2017-01-01

    Ammonia and odor emissions from livestock production systems cause negative impact on atmospheric environment and local society. It is, therefore, important to develop cost-effective methods to reduce these emissions. Air cleaning technologies, including chemical and biological filters, have been...... proposed to clean the exhaust ventilation air from confined livestock buildings. However, it requires large capacity of the air cleaning unit for the total exhaust air and, consequently, results in high investment and operational costs of the livestock production system. Aiming at emission reduction...... and optimal indoor air quality of confined farm animal buildings, a concept of partial pit ventilation has been investigated in varied conditions in Denmark. Partial pit ventilation is based on the hypothesis that the most polluted air can be removed by a separate air exhaust near the pollution sources in pit...

  17. Investigating the adaptive model of thermal comfort for naturally ventilated school buildings in Taiwan.

    Science.gov (United States)

    Hwang, Ruey-Lung; Lin, Tzu-Ping; Chen, Chen-Peng; Kuo, Nai-Jung

    2009-03-01

    Divergence in the acceptability to people in different regions of naturally ventilated thermal environments raises a concern over the extent to which the ASHRAE Standard 55 may be applied as a universal criterion of thermal comfort. In this study, the ASHRAE 55 adaptive model of thermal comfort was investigated for its applicability to a hot and humid climate through a long-term field survey performed in central Taiwan among local students attending 14 elementary and high schools during September to January. Adaptive behaviors, thermal neutrality, and thermal comfort zones are explored. A probit analysis of thermal acceptability responses from students was performed in place of the conventional linear regression of thermal sensation votes against operative temperature to investigate the limits of comfort zones for 90% and 80% acceptability; the corresponding comfort zones were found to occur at 20.1-28.4 degrees C and 17.6-30.0 degrees C, respectively. In comparison with the yearly comfort zones recommended by the adaptive model for naturally ventilated spaces in the ASHRAE Standard 55, those observed in this study differ in the lower limit for 80% acceptability, with the observed level being 1.7 degrees C lower than the ASHRAE-recommended value. These findings can be generalized to the population of school children, thus providing information that can supplement ASHRAE Standard 55 in evaluating the thermal performance of naturally ventilated school buildings, particularly in hot-humid areas such as Taiwan.

  18. Investigating the adaptive model of thermal comfort for naturally ventilated school buildings in Taiwan

    Science.gov (United States)

    Hwang, Ruey-Lung; Lin, Tzu-Ping; Chen, Chen-Peng; Kuo, Nai-Jung

    2009-03-01

    Divergence in the acceptability to people in different regions of naturally ventilated thermal environments raises a concern over the extent to which the ASHRAE Standard 55 may be applied as a universal criterion of thermal comfort. In this study, the ASHRAE 55 adaptive model of thermal comfort was investigated for its applicability to a hot and humid climate through a long-term field survey performed in central Taiwan among local students attending 14 elementary and high schools during September to January. Adaptive behaviors, thermal neutrality, and thermal comfort zones are explored. A probit analysis of thermal acceptability responses from students was performed in place of the conventional linear regression of thermal sensation votes against operative temperature to investigate the limits of comfort zones for 90% and 80% acceptability; the corresponding comfort zones were found to occur at 20.1-28.4°C and 17.6-30.0°C, respectively. In comparison with the yearly comfort zones recommended by the adaptive model for naturally ventilated spaces in the ASHRAE Standard 55, those observed in this study differ in the lower limit for 80% acceptability, with the observed level being 1.7°C lower than the ASHRAE-recommended value. These findings can be generalized to the population of school children, thus providing information that can supplement ASHRAE Standard 55 in evaluating the thermal performance of naturally ventilated school buildings, particularly in hot-humid areas such as Taiwan.

  19. Reducing Mortality from Terrorist Releases of Chemical and Biological Agents: I. Filtration for Ventilation Systems in Commercial Building

    Energy Technology Data Exchange (ETDEWEB)

    Thatcher, Tracy L.; Daisey, Joan M.

    1999-09-01

    There is growing concern about potential terrorist attacks involving releases of chemical and/or biological (CB) agents, such as sarin or anthrax, in and around buildings. For an external release, the CB agent can enter the building through the air intakes of a building's mechanical ventilation system and by infiltration through the building envelope. For an interior release in a single room, the mechanical ventilation system, which often recirculates some fraction of the air within a building, may distribute the released CB agent throughout the building. For both cases, installing building systems that remove chemical and biological agents may be the most effective way to protect building occupants. Filtration systems installed in the heating, ventilating and air-conditioning (HVAC) systems of buildings can significantly reduce exposures of building occupants in the event of a release, whether the release is outdoors or indoors. Reduced exposures can reduce the number of deaths from a terrorist attack. The purpose of this report is to provide information and examples of the design of filtration systems to help building engineers retrofit HVAC systems. The report also provides background information on the physical nature of CB agents and brief overviews of the basic principles of particle and vapor filtration.

  20. Thermal comfort in naturally ventilated and air-conditioned buildings in humid subtropical climate zone in China.

    Science.gov (United States)

    Yang, Wei; Zhang, Guoqiang

    2008-05-01

    A thermal comfort field study has been carried out in five cities in the humid subtropical climate zone in China. The survey was performed in naturally ventilated and air-conditioned buildings during the summer season in 2006. There were 229 occupants from 111 buildings who participated in this study and 229 questionnaire responses were collected. Thermal acceptability assessment reveals that the indoor environment in naturally ventilated buildings could not meet the 80% acceptability criteria prescribed by ASHRAE Standard 55, and people tended to feel more comfortable in air-conditioned buildings with the air-conditioned occupants voting with higher acceptability (89%) than the naturally ventilated occupants (58%). The neutral temperatures in naturally ventilated and air-conditioned buildings were 28.3 degrees C and 27.7 degrees C, respectively. The range of accepted temperature in naturally ventilated buildings (25.0-31.6 degrees C) was wider than that in air-conditioned buildings (25.1-30.3 degrees C), which suggests that occupants in naturally ventilated buildings seemed to be more tolerant of higher temperatures. Preferred temperatures were 27.9 degrees C and 27.3 degrees C in naturally ventilated and air-conditioned buildings, respectively, both of which were 0.4 degrees C cooler than neutral temperatures. This result suggests that people of hot climates may use words like "slightly cool" to describe their preferred thermal state. The relationship between draught sensation and indoor air velocity at different temperature ranges indicates that indoor air velocity had a significant influence over the occupants' comfort sensation, and air velocities required by occupants increased with the increasing of operative temperatures. Thus, an effective way of natural ventilation which can create the preferred higher air movement is called for. Finally, the indoor set-point temperature of 26 degrees C or even higher in air-conditioned buildings was confirmed as making

  1. Modeling ventilation rates in bedrooms based on building characteristics and occupant behavior

    DEFF Research Database (Denmark)

    Bekö, Gabriel; Toftum, Jørn; Clausen, Geo

    2011-01-01

    (lowest ACR in buildings from early 1970s), observed condensation on the bedroom window (higher ACR at less condensation), etc. The best-fitting model explained 46% of the variability in the air change rates. Variables related to occupant behavior were stronger predictors of ventilation rate (model R2 ¼ 0.......30) than those related to building characteristics (model R2 ¼ 0.09). Although not perfectly accurate on a room-to-room basis, our best-fitting model may be useful when a rough estimate of the average air change rate for larger study populations is required in future indoor air quality models.......Air change rate (ACR) data obtained from the bedrooms of 500 Danish children and presented in an earlier paper were analyzed in more detail. Questionnaires distributed to the families, home inspections and interviews with the parents provided information about a broad range of residential...

  2. Role of mechanical ventilation in the airborne transmission of infectious agents in buildings.

    Science.gov (United States)

    Luongo, J C; Fennelly, K P; Keen, J A; Zhai, Z J; Jones, B W; Miller, S L

    2016-10-01

    Infectious disease outbreaks and epidemics such as those due to SARS, influenza, measles, tuberculosis, and Middle East respiratory syndrome coronavirus have raised concern about the airborne transmission of pathogens in indoor environments. Significant gaps in knowledge still exist regarding the role of mechanical ventilation in airborne pathogen transmission. This review, prepared by a multidisciplinary group of researchers, focuses on summarizing the strengths and limitations of epidemiologic studies that specifically addressed the association of at least one heating, ventilating and/or air-conditioning (HVAC) system-related parameter with airborne disease transmission in buildings. The purpose of this literature review was to assess the quality and quantity of available data and to identify research needs. This review suggests that there is a need for well-designed observational and intervention studies in buildings with better HVAC system characterization and measurements of both airborne exposures and disease outcomes. Studies should also be designed so that they may be used in future quantitative meta-analyses. © 2015 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. The Elgaard project. Energy-saving experiments. Older versus modern ventilation of barns; Projekt Elgaard; Energispareforsoeg. Aeldre kontra moderne staldventilation

    Energy Technology Data Exchange (ETDEWEB)

    Gudbjerg, E.; Guul-Simonsen, F.

    1993-07-01

    The survey comprised examination of relevant theoretical data concerning livestock ventilation together with heat recovery tests and tests with ventilation units in climate-controlled livestock buildings, in which existing units were rebuilt or replaced with new modern types, for examination of electricity saving possibilities. Moreover, considerations were made on existing research requirements within the field. It was concluded that electricity consumption for heating and ventilation purposes can be reduced by 30-60%, when using modern ventilation units, and if the humidity control unit is adjusted in accordance with seasonal weather variations. Control units used for livestock ventilation units are not equally applicable for control of the indoor climate, which may result in inexpedient temperature and humidity fluctuations. Heat recovery of ventilation air can be made in climate-controlled livestock units over a 2-5 years refund period. Well-maintained heat exchangers influence the indoor climate positively. Development of energy-control in climate-controlled buildings for piglets is needed, using methods for calculating annual energy consumption under given conditions for given ventilation and heating units or methods for evaluation of the coherence between stability of the indoor climate, managerial economics and pig growth. As the degree-day method is inapplicable, a method for correction of test data from livestock buildings in relation to data on outdoor climate should be developed in addition to methods for dimensioning and testing heat exchangers. (AB)

  4. Influence of placement and height of high-rise buildings on wind pressure distribution and natural ventilation of low- and medium-rise buildings

    Czech Academy of Sciences Publication Activity Database

    Kuznetsov, Sergeii; Butova, A.; Pospíšil, Stanislav

    2016-01-01

    Roč. 15, 3/4 (2016), s. 253-266 ISSN 1473-3315 R&D Projects: GA ČR(CZ) GA14-12892S; GA MŠk(CZ) LO1219 Keywords : natural ventilation * high-rise buildings * low- and medium-rise buildings * wind pressure coefficient * wind tunnel tests Subject RIV: JM - Building Engineering Impact factor: 0.391, year: 2016 http://www.tandfonline.com/doi/full/10.1080/14733315.2016.1214396

  5. Natural Ventilation of Buildings through Light Shafts. Design-Based Solution Proposals

    Science.gov (United States)

    Ángel Padilla-Marcos, Miguel; Meiss, Alberto; Feijó-Muñoz, Jesús

    2017-10-01

    This work analyses how the built environment affects the quality of the air to be introduced into buildings from light shafts. Several factors such as urban environment and building design intervene in the ability of the light shaft to produce its air change process. Urban areas continuously pollute the air in cities which affects the human health and the environment sustainability. Poor air quality outside buildings supposes a big energy waste to promote an acceptable air quality inside buildings. That requires a large flow rate to maintain the indoor air quality which is translated to an energy efficiency term. The main objective focuses on the impact of standardized architecture design in the quality of the indoor air dependent on the air change in the light shaft. The air change capacity of the outdoor space is numbered analysed using the concept of air change efficiency (ACE). ACE is determined by the built environment, the wind conditions and the design of the building containing light shafts. This concept is comparatively evaluated inside a control domain virtually defined to obtain the mean age of the air for a known air volume. The longer the light shaft in the wind direction is, the better the ACE is compared with other options. Light shafts up to 12 metres high are the most suitable in order to obtain acceptable efficiency results. Other studied cases verify that assumption. Different simplified tools for the technicians to evaluate the design of buildings containing light shafts are proposed. Some strategies of architectural design of buildings with light shafts to be used for ventilation are presented.

  6. Developing evidence-based prescriptive ventilation rate standards for commercial buildings in California: a proposed framework

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J.; Fisk, William J.

    2014-02-01

    Background - The goal of this project, with a focus on commercial buildings in California, was to develop a new framework for evidence-based minimum ventilation rate (MVR) standards that protect occupants in buildings while also considering energy use and cost. This was motivated by research findings suggesting that current prescriptive MVRs in commercial buildings do not provide occupants with fully safe and satisfactory indoor environments. Methods - The project began with a broad review in several areas ? the diverse strategies now used for standards or guidelines for MVRs or for environmental contaminant exposures, current knowledge about adverse human effects associated with VRs, and current knowledge about contaminants in commercial buildings, including their their presence, their adverse human effects, and their relationships with VRs. Based on a synthesis of the reviewed information, new principles and approaches are proposed for setting evidence-based VRs standards for commercial buildings, considering a range of human effects including health, performance, and acceptability of air. Results ? A review and evaluation is first presented of current approaches to setting prescriptive building ventilation standards and setting acceptable limits for human contaminant exposures in outdoor air and occupational settings. Recent research on approaches to setting acceptable levels of environmental exposures in evidence-based MVR standards is also described. From a synthesis and critique of these materials, a set of principles for setting MVRs is presented, along with an example approach based on these principles. The approach combines two sequential strategies. In a first step, an acceptable threshold is set for each adverse outcome that has a demonstrated relationship to VRs, as an increase from a (low) outcome level at a high reference ventilation rate (RVR, the VR needed to attain the best achievable levels of the adverse outcome); MVRs required to meet each

  7. Comparative study on the ventilation mode of the residential building in Beijing area in winter

    Science.gov (United States)

    Wang, G. J.; Li, Q. P.; Guo, Y.; Hu, Y. H.

    2016-08-01

    With the development of residential energy conservation technology, the air tightness requirement of the window is higher and higher. So in winter the cold penetration wind cannot satisfy the requirement of indoor personnel to fresh air. The common ventilation mode includes natural ventilation, natural inlet and mechanical exhaust, wall type ventilator with heat exchange, ventilation unit with heat exchange. Looking for energy saving, comfortable way of ventilation, the application effect of the way of ventilation is evaluated in air distribution and comfort performance and the initial investment by FLUENT software. The conclusion is that the mode of ventilation unit with heat exchange has higher superiority compared with the others.

  8. Moisture condensation on building envelopes in differential ventilated spaces in the tropics: quantitative assessment of influencing factors

    Directory of Open Access Journals (Sweden)

    Ali Maisarah

    2016-01-01

    Full Text Available Ventilation systems play a significant role in maintaining the indoor thermal and hygric balance. Nevertheless, the systems had been implicated to result in many problems. In the tropical climate, especially for energy efficiency purposes, building spaces are operated with differential ventilation. Such spaces operate on 24-hrs basis, some on 8-hrs while others are either naturally ventilated or served with mechanical supply-exhaust fan systems with non-conditioned outdoor air. This practice had been found to result in condensation problems. This study involves a quantitative appraisal of the effect of operative conditions and hygrothermal quality of building envelopes on condensation risk. The in-situ experiment is combined with an analytical approach to assessing the hygrothermal quality of building envelopes in a tropical climate building under differential ventilation between adjacent spaces. The case-studied building is with a known history of condensation and associated damages including mould growth. The microclimate measurement and hygrothermal performance of the wall and floor against condensation and mould growth risks had been previously reported elsewhere. As a step further, the present study evaluates the effects of various envelope insulation types and configurations together with the HVAC cooling set-points on envelope hygrothermal performance. The results revealed that overcooling the air-conditioned side increases condensation risk on the non-air-conditioned side of the envelopes. The envelopes failed criteria for surface condensation at existing operative conditions irrespective of envelope hygrothermal quality improvements. However, the envelope performed well at improved cooling operative conditions even at existing envelope hygrothermal quality. It is, therefore, important to ascertain the envelope hygrothermal quality as well the cooling operative conditions while embarking on energy efficiency operations in mechanical

  9. Natural Ventilation Building Design Approach in Mediterranean Regions—A Case Study at the Valencian Coastal Regional Scale (Spain

    Directory of Open Access Journals (Sweden)

    Miguel Mora-Pérez

    2016-08-01

    Full Text Available Environmental awareness has led to an increased concern about low carbon technologies implementation. Among these technologies, the following research is focused on the natural ventilation effect evaluation in buildings prior to its construction. The aim is to select the most suitable architectural solution to ensure comfortable indoor environment in the most efficient way in the early building design stage. The design approach takes into account the wind conditions in the region and the building surroundings to evaluate the façade opening distribution impact on natural ventilation performance. The design approach is based on computational fluid dynamics (CFD. In this article, a case study located in the Valencian Community (Spain is depicted. The Valencian Community coastal climatic conditions are evaluated to assess the low carbon technology energy saving potential. Moreover, the main drivers and barriers involved in the design approach implementation in the region are discussed. The conclusions show that the natural ventilation design approach can improve up to 9.7% the building energy performance respect an initial building design, in which natural ventilation has not been considered. The results contribute to an assessment of the complete low carbon technology effect in the region.

  10. Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols; Kolokotroni, Maria

    -of-the-art of ventilative cooling potentials and limitations, its consideration in current energy performance regulations, available building components and control strategies and analysis methods and tools. In addition, the report provides twenty six examples of operational buildings using ventilative cooling ranging from...

  11. Natural ventilation - A new method based on the Walton model applied to cross-ventilated buildings having two large external openings

    CERN Document Server

    Bastide, Alain; Boyer, Harry

    2012-01-01

    In order to provide comfort in a low energy consumption building, it is preferable to use natural ventilation rather than HVAC systems. To achieve this, engineers need tools that predict the heat and mass transfers between the building's interior and exterior. This article presents a method implemented in some building software, and the results are compared to CFD. The results show that the knowledge model is not sufficiently well-described to identify all the physical phenomena and the relationships between them. A model is developed which introduces a new building-dependent coefficient allowing the use of Walton's model, as extended by Roldan to large external openings, and which better represents the turbulent phenomena near large external openings. The formulation of the mass flow rates is inversed to identify modeling problems. It appears that the discharge coefficient is not the only or best parameter to obtain an indoor static pressure compatible with CFD results, or to calculate more realistic mass fl...

  12. Occupant Time Period of Thermal Adaption to Change of Outdoor Air Temperature in Naturally Ventilated Buildings

    DEFF Research Database (Denmark)

    liu, weiwei; Wargocki, Pawel; Xiong, Jing

    2014-01-01

    The present work proposed a method to determine time period of thermal adaption of occupants in naturally ventilated building, based on the relationship between their neutral temperatures and running mean outdoor air temperature. Based on the data of the field investigation, the subjects’ time...... period of thermal adaption was obtained with the proposed method. The result revealed that the subjects needed to take 4.25 days to fully adapt to a step-change in outdoor air temperature. The time period of thermal adaption for the occupants in five European countries was also calculated and compared...... with the value of the subjects in this study. The comparison shows that the occupants in China had a shorter time period of thermal adaption than European occupants, which means that Chinese occupants can adapt to a new outdoor climate condition faster....

  13. Optimization and Performance Study of Select Heating Ventilation and Air Conditioning Technologies for Commercial Buildings

    Science.gov (United States)

    Kamal, Rajeev

    Buildings contribute a significant part to the electricity demand profile and peak demand for the electrical utilities. The addition of renewable energy generation adds additional variability and uncertainty to the power system. Demand side management in the buildings can help improve the demand profile for the utilities by shifting some of the demand from peak to off-peak times. Heating, ventilation and air-conditioning contribute around 45% to the overall demand of a building. This research studies two strategies for reducing the peak as well as shifting some demand from peak to off-peak periods in commercial buildings: 1. Use of gas heat pumps in place of electric heat pumps, and 2. Shifting demand for air conditioning from peak to off-peak by thermal energy storage in chilled water and ice. The first part of this study evaluates the field performance of gas engine-driven heat pumps (GEHP) tested in a commercial building in Florida. Four GEHP units of 8 Tons of Refrigeration (TR) capacity each providing air-conditioning to seven thermal zones in a commercial building, were instrumented for measuring their performance. The operation of these GEHPs was recorded for ten months, analyzed and compared with prior results reported in the literature. The instantaneous COPunit of these systems varied from 0.1 to 1.4 during typical summer week operation. The COP was low because the gas engines for the heat pumps were being used for loads that were much lower than design capacity which resulted in much lower efficiencies than expected. The performance of equivalent electric heat pump was simulated from a building energy model developed to mimic the measured building loads. An economic comparison of GEHPs and conventional electrical heat pumps was done based on the measured and simulated results. The average performance of the GEHP units was estimated to lie between those of EER-9.2 and EER-11.8 systems. The performance of GEHP systems suffers due to lower efficiency at

  14. Influence of input data on airflow network accuracy in residential buildings with natural wind- and stack-driven ventilation

    DEFF Research Database (Denmark)

    Arendt, Krzysztof; Krzaczek, Marek; Tejchman, Jacek

    2017-01-01

    The airflow network (AFN) modeling approach provides an attractive balance between the accuracy and computational demand for naturally ventilated buildings. Its accuracy depends on input parameters such as wind pressure and opening discharge coefficients. In most cases, these parameters...... is still poor. In this paper, the influence of wind pressure data on the accuracy of a coupled AFN-BES model for a real building with natural wind- and stack-driven ventilation was analyzed. The results of 8 computation cases with different wind pressure data from secondary sources were compared...... are obtained from secondary sources which are solely representative for very simplified buildings, i.e. for buildings without facade details. Although studies comparing wind pressure coefficients or discharge coefficients from different sources exist, the knowledge regarding the effect of input data on AFN...

  15. Experimental study of diffuse ceiling ventilation coupled with a thermally activated building construction in an office room

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per Kvols; Pomianowski, Michal Zbigniew

    2015-01-01

    This paper presents and analyses the performance of an integrated system with diffuse ceiling ventilation and a thermally activated building construction. A full-scale experiment is carried out in a hot box with an office setup. The performance of the integrated system is evaluated under different...

  16. Effect of ventilation on perceived quality of air polluted by building materials. A summary of reported data

    Energy Technology Data Exchange (ETDEWEB)

    Wargocki, P.; Vondruskova, J. (International Centre for Indoor Environment and Energy, Dept. of Mechanical Engineering, DTU, Kgs. Lyngby (DK)); Knudsen, Henrik N. (Danish Building Research Institute, Aalborg Univ., Hoersholm (DK))

    2007-02-15

    This paper summarizes existing data on how varying ventilation rates affect the perceived quality of air polluted by building materials. This is done by reviewing literature dealing with exposure-response relationships, i.e. the log-linear relationships between the concentration of pollutants (exposure) and the perceived air quality (response). The reviewed data originate from studies with single building materials performed in small-scale ventilated chambers and from studies carried out in a full-scale setting resembling normal offices. Perceived air quality expressed in terms of acceptability as assessed by untrained panels was included. The results show that the exposure-response relationships vary for different building materials as regards the impact of changing ventilation rate on perceived air quality and the level of perceived air quality at a constant ventilation rate. This applies both for the data collected in small-scale and in full-scale experiments. The differences may be caused by the experimental conditions, psychological factors, physiological factors, and chemical/physical factors. A well controlled study taking these factors into account with several different building materials, is thus recommended to further study whether the observed results have practical significance. These experiments should be carried out under realistic fullscale conditions. (au)

  17. Building America Top Innovations 2014 Profile: ASHRAE Standard 62.2. Ventilation and Acceptable Indoor Air Quality in Low-Rise Residential Buildings

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2014-11-01

    This 2014 Top Innovations profile describes Building America research and support in developing and gaining adoption of ASHRAE 62.2, a residential ventilation standard that is critical to transforming the U.S. housing industry to high-performance homes.

  18. [Biological contamination in office buildings related to ventilation/air conditioning system].

    Science.gov (United States)

    Bródka, Karolina; Sowiak, Małgorzata; Kozajda, Anna; Cyprowski, Marcin; Irena, Szadkowska-Stańczyk

    2012-01-01

    Indoor air is contaminated with microorganisms coming from both the atmospheric air and sources present in premises. The aim of this study was to analyze the concentrations of biological agents in office buildings, dependending on ventilation/air conditioning system and season. The study covered office buildings (different in the system of ventila-tion/air conditioning). Air samples for assessing the levels of inhalable dust, endotoxins and (1-->3)-beta-D-glucans, were taken at the selected stationary points of each building during summer and winter. The air was sampled for 6 h, using portable sets consisting of the GilAir 5 pump and the head filled with a filter of fiber glass. The samples for the presence of airborne bacteria and fungi were collected twice during the day using the impaction method. Average concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans in office premises were 0.09 mg/m3, 6.00 x 10(2) cfu/m3, 4.59 x 10(1) cfu/m3, 0.42 ng/m3 and 3.91 ng/m3, respectively. Higher concentrations of the investigated agents were found in summer. In premises with air conditioning concentrations of airborne fungi, (1-->3)-beta-D-glucans and inhalable dust were significantly lower in winter. In summer the trend was reverse except for (1-->3)-beta-D-glucans. Concentrations of biological agents were affected by the season and the presence of air conditioning. Concentrations of inhalable dust, bacteria, fungi, endotoxins and (1-->3)-beta-D-glucans, observed inside the office buildings, were significantly higher in summer than in winter. The presence of the air conditioning system modified in various ways the levels of biological agents. Its influence was greater on the concentration of fungi and (1-->3)-beta-D-glucans than on that of bacteria and endotoxins.

  19. Humidity conditions in renovated high-rise buildings with three ventilation solutions. Luftfugtighed i renoverede hoejhuse med tre ventilationsloesninger

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, O.

    1989-01-01

    In connection with the renovation of two high-rise apartment buildings using different methods of ventilation The Danish Building Research Institute examined humidity conditions before and after renovation took place. Air velocities in the living area of one of the buildings were also examined. The methods of ventilation were those which occurs naturally through leaks and open windows only - with mechanical injection in living area and mechanical exhaust from kitchen and bathroom in addition to 20 cm2 outdoor air valve in living area facade and, thirdly, with sealed facades, windows and doors and a 30 cm2 valve in the facade of each room. Air velocity conditions were measured in three flats where mechanical injection and exhaust were established and where part of the indoor air was taken in unheated through valves in the facade. Significant variations were found in relation to the three ventilation methods. Significant variations in humidity conditions were found in relation to the three ventilation solutions. In the building with mechanical injection and exhaust the air humidity conditions were measured as satisfactory. Only in a few flats did the air humidity exceed the limit which might cause condensed moisture on normal double-glazed windows and above the value of about 45 per cent RF at 21 deg. C, often recommended as the upper limit in the coldest season to combat house dust mites. In the building with the original ventilation, with re-sealed facade and installation of a 30 cm2 valve in the facade of each room too high air humidities were measured in many of the flats. The mechanically injected air flow, and the air entering through the outdoor valves did not in general create too high air velocities in the living areas. (AB).

  20. Lifecycle performance. Special issue on management and maintenance, hybrid ventilation concepts, installation-low buildings; Lifecycle performance. Themanummer over beheer en onderhoud, hybride ventilatieconcepten, installatie-arme gebouwen

    Energy Technology Data Exchange (ETDEWEB)

    Thierauf, I. [Universiteit Utrecht, Utrecht (Netherlands); Kurvers, S.R.; Van den Ham, E.R.; Leijten, J.L. [Sectie Climate Design and Sustainability, Afdeling Architectural Engineering and Technology, Faculteit Bouwkunde, Technische Universiteit Delft TUD, Delft (Netherlands); Juricic, S. [Ecole National des Travaux Publics de l' Etat, Lyon (France); Jacobs, P. [Afdeling Energy and Comfort Systems, TNO, Delft (Netherlands); Versteeg, H. [LBP Sight, Nieuwegein (Netherlands); Van Loon, P.P.M. [Stichting Scholen van Morgen, Rotterdam (Netherlands); Hoek, H.C.; Van Eeden, H.; Nibbelink, J. [Collectief C-on, Haarlem (Netherlands); Veerman, J.; Maassen, W.H. [Royal Haskoning DHV, Nijmegen (Netherlands); Derksen, A.H.P. [ISSO, Rotterdam (Netherlands); Morren, K. [Universiteit Twente, Enschede (Netherlands)

    2012-12-15

    In 9 articles various aspects regarding the title topic are discussed: energy efficiency and user comfort, ventilation in new houses with balanced ventilation, the revised assessment for ventilation performance, air quality in school buildings, buildings with only a few installations, hybrid ventilation, the management and maintenance process, and future performance requirements [Dutch] In 9 artikelen wordt aandacht besteed aan diverse aspecten m.b.t. het titelonderwerp: energie-efficientie en gebruikerscomfort, ventilatie in nieuwbouwwoningen met balansventilatie, de herziene beoordelingsrichtlijn ventilatie prestatie, luchtkwaliteit in schoolgebouwen, installatie-arme gebouwen, hybride ventilatie, het beheer- en onderhoudsproces, en de toekomstige prestatie-eisen.

  1. Potential for passive cooling of buildings by night-time ventilation in present and future climates in Europe

    DEFF Research Database (Denmark)

    Artmann, Nikolai; Manz, Heinrich; Heiselberg, Per

    2006-01-01

    Given the general shift in recent decades towards a lower heating and higher cooling demand for buildings in many European countries, passive cooling by night-time ventilation has come to be seen as a promising option, particularly in the moderate or cold climates of Central, Eastern and Northern......-time ventilation alone might not suffice to guarantee thermal comfort. It should also be remembered that climatic cooling potential is likely to have fallen appreciably by the end of the 21st century due to climate warming....

  2. The Effects of Air Permeability, Background Ventilation and Lifestyle on Energy Performance, Indoor Air Quality and Risk of Condensation in Domestic Buildings

    Directory of Open Access Journals (Sweden)

    Arman Hashemi

    2015-04-01

    Full Text Available Effective and efficient ventilation is essential when improving energy performance and Indoor Air Quality (IAQ of buildings. Reducing air permeability can considerably improve the energy performance of buildings; however, making the buildings more airtight may result in lower rates of natural ventilation which may in turn increase the risks of condensation and unacceptable IAQ. This study evaluates the effects of different air permeability rates, background ventilation and occupants’ lifestyles on the energy performance as well as the risk of condensation and CO2 concentration in domestic buildings. Dynamic computer simulations were conducted in EnergyPlus. Results indicated direct relations between the ventilation rates, energy performance and IAQ. Higher air permeability along with background ventilation resulted in considerably better IAQ while energy consumption increased by up to four times. Occupants’ lifestyles were identified as a major contributor to the risk of condensation.

  3. Indoor air quality and occupant satisfaction in five mechanically and four naturally ventilated open-plan office buildings

    DEFF Research Database (Denmark)

    Hummelgaard, J.; Juhl, P.; Saebjornsson, K.O.

    2007-01-01

    Occupant responses and indoor environment characteristics were recorded and compared in five mechanically and four naturally ventilated open-plan office buildings by using a simple approach that enabled us to survey many buildings simultaneously. All occupant responses were obtained during one...... afternoon. In a pre-experiment, temperature and the concentration Of CO2 were monitored in 2-10 locations/office to evaluate the variation throughout the offices. A representative measurement point was subsequently selected and measurements of the same parameters were made during one week. All offices were...... monitored during the same week and occupant responses to the indoor environment were collected via the internet on the same day within that week. The temperature and the CO2 concentration varied more and were in some cases higher in the naturally ventilated buildings, but occupant responses in terms...

  4. Natural Ventilation: A Mitigation Strategy to Reduce Overheating In Buildings under Urban Heat Island Effect in South American Cities

    Science.gov (United States)

    Palme, Massimo; Carrasco, Claudio; Ángel Gálvez, Miguel; Inostroza, Luis

    2017-10-01

    Urban heat island effect often produces an increase of overheating sensation inside of buildings. To evacuate this heat, the current use of air conditioning increases the energy consumption of buildings. As a good alternative, natural ventilation is one of the best strategies to obtain indoor comfort conditions, even in summer season, if buildings and urban designs are appropriated. In this work, the overheating risk of a small house is evaluated in four South American cities: Guayaquil, Lima, Antofagasta and Valparaíso, with and without considering the UHI effect. Then, natural ventilation is assessed in order to understand the capability of this passive strategy to assure comfort inside the house. Results show that an important portion of the indoor heat can be evacuated, however the temperature rising (especially during the night) due to UHI can generate a saturation effect if appropriate technical solutions, like the increase in the air speed that can be obtained with good urban design, are not considered.

  5. Simulations of the impacts of building height layout on air quality in natural-ventilated rooms around street canyons.

    Science.gov (United States)

    Yang, Fang; Zhong, Ke; Chen, Yonghang; Kang, Yanming

    2017-10-01

    Numerical simulations were conducted to investigate the effects of building height ratio (i.e., HR, the height ratio of the upstream building to the downstream building) on the air quality in buildings beside street canyons, and both regular and staggered canyons were considered for the simulations. The results show that the building height ratio affects not only the ventilation fluxes of the rooms in the downstream building but also the pollutant concentrations around the building. The parameter, outdoor effective source intensity of a room, is then proposed to calculate the amount of vehicular pollutants that enters into building rooms. Smaller value of this parameter indicates less pollutant enters the room. The numerical results reveal that HRs from 2/7 to 7/2 are the favorable height ratios for the regular canyons, as they obtain smaller values than the other cases. While HR values of 5/7, 7/7, and 7/5 are appropriate for staggered canyons. In addition, in terms of improving indoor air quality by natural ventilation, the staggered canyons with favorable HR are better than those of the regular canyons.

  6. Calibration of a Sensor Array (an Electronic Tongue for Identification and Quantification of Odorants from Livestock Buildings

    Directory of Open Access Journals (Sweden)

    Jens Jørgen Lønsmann Iversen

    2007-01-01

    Full Text Available This contribution serves a dual purpose. The first purpose was to investigate the possibility of using a sensor array (an electronic tongue for on-line identification and quantification of key odorants representing a variety of chemical groups at two different acidities, pH 6 and 8. The second purpose was to simplify the electronic tongue by decreasing the number of electrodes from 14, which was the number of electrodes in the prototype. Different electrodes were used for identification and quantification of different key odorants. A total of eight electrodes were sufficient for identification and quantification in micromolar concentrations of the key odorants n-butyrate, ammonium and phenolate in test mixtures also containing iso-valerate, skatole and p-cresolate. The limited number of electrodes decreased the standard deviation and the relative standard deviation of triplicate measurements in comparison with the array comprising 14 electrodes. The electronic tongue was calibrated using 4 different test mixtures, each comprising 50 different combinations of key odorants in triplicates, a total of 600 measurements. Back propagation artificial neural network, partial least square and principal component analysis were used in the data analysis. The results indicate that the electronic tongue has a promising potential as an on- line sensor for odorants absorbed in the bioscrubber used in livestock buildings.

  7. Calibration of a Sensor Array (an Electronic Tongue) for Identification and Quantification of Odorants from Livestock Buildings

    Science.gov (United States)

    Abu-Khalaf, Nawaf; Iversen, Jens Jørgen Lønsmann

    2007-01-01

    This contribution serves a dual purpose. The first purpose was to investigate the possibility of using a sensor array (an electronic tongue) for on-line identification and quantification of key odorants representing a variety of chemical groups at two different acidities, pH 6 and 8. The second purpose was to simplify the electronic tongue by decreasing the number of electrodes from 14, which was the number of electrodes in the prototype. Different electrodes were used for identification and quantification of different key odorants. A total of eight electrodes were sufficient for identification and quantification in micromolar concentrations of the key odorants n-butyrate, ammonium and phenolate in test mixtures also containing iso-valerate, skatole and p-cresolate. The limited number of electrodes decreased the standard deviation and the relative standard deviation of triplicate measurements in comparison with the array comprising 14 electrodes. The electronic tongue was calibrated using 4 different test mixtures, each comprising 50 different combinations of key odorants in triplicates, a total of 600 measurements. Back propagation artificial neural network, partial least square and principal component analysis were used in the data analysis. The results indicate that the electronic tongue has a promising potential as an online sensor for odorants absorbed in the bioscrubber used in livestock buildings.

  8. Ventilation Effectiveness

    DEFF Research Database (Denmark)

    Mundt, M.; Mathisen, H. M.; Moser, M.

    Improving the ventilation effectiveness allows the indoor air quality to be significantly enhanced without the need for higher air changes in the building, thereby avoiding the higher costs and energy consumption associated with increasing the ventilation rates. This Guidebook provides easy...

  9. Parameter Estimation of Dynamic Multi-zone Models for Livestock Indoor Climate Control

    DEFF Research Database (Denmark)

    Wu, Zhuang; Stoustrup, Jakob; Heiselberg, Per

    2008-01-01

    , the livestock, the ventilation system and the building on the dynamic performance of indoor climate. Some significant parameters employed in the climate model as well as the airflow interaction between each conceptual zone are identified with the use of experimental time series data collected during spring...... and winter at a real scale livestock building in Denmark. The obtained comparative results between the measured data and the simulated output confirm that a very simple multi-zone model can capture the salient dynamical features of the climate dynamics which are needed for control purposes....

  10. Recommended Changes to Specifications for Demand Controlled Ventilation in California's Title 24 Building Energy Efficiency Standards

    Energy Technology Data Exchange (ETDEWEB)

    Fisk, William J.; Sullivan, Douglas P.; Faulkner, David

    2010-04-08

    In demand-controlled ventilation (DCV), rates of outdoor air ventilation are automatically modulated as occupant density varies. The objective is to keep ventilation rates at or above design specifications and code requirements and also to save energy by avoiding excessive ventilation rates. DCV is most often used in spaces with highly variable and sometime dense occupancy. In almost all cases, carbon dioxide (CO{sub 2}) sensors installed in buildings provide the signal to the ventilation rate control system. People produce and exhale CO{sub 2} as a consequence of their normal metabolic processes; thus, the concentrations of CO{sub 2} inside occupied buildings are higher than the concentrations of CO{sub 2} in the outdoor air. The magnitude of the indoor-outdoor CO{sub 2} concentration difference decreases as the building's ventilation rate per person increases. The difference between the indoor and outdoor CO{sub 2} concentration is also a proxy for the indoor concentrations of other occupant-generated bioeffluents, such as body odors. Reviews of the research literature on DCV indicate a significant potential for energy savings, particularly in buildings or spaces with a high and variable occupancy. Based on modeling, cooling energy savings from applications of DCV are as high as 20%. With support from the California Energy Commission and the U.S. Department of Energy, the Lawrence Berkeley National Laboratory has performed research on the performance of CO{sub 2} sensing technologies and optical people counters for DCV. In addition, modeling was performed to evaluate the potential energy savings and cost effectiveness of using DCV in general office spaces within the range of California climates. The above-described research has implications for the specifications pertaining to DCV in section 121 of the California Title 24 Standard. Consequently, this document suggests possible changes in these specifications based on the research findings. The suggested

  11. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Commercial Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    none,

    2011-09-01

    This report covers an assessment of 182 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. commercial buildings to identify and provide analysis on 17 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, description of technical maturity, description of non-energy benefits, description of current barriers for market adoption, and description of the technology’s applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  12. Designing and testing an air-PCM heat exchanger for building ventilation application coupled to energy storage

    OpenAIRE

    Dechesne, Bertrand; Gendebien, Samuel; Martens, Jonathan; Gilbert, Jacques; Lemort, Vincent

    2014-01-01

    This paper studies a PCM heat exchanger coupled to a building ventilation system. This PCM module can either store heat during the day (e.g. by cooling solar PV panels) and restore it to the building during the night for space heating purposes or store coolness during the night and give it back during the day and thus act as a free cooling system. This project aims to develop a performing air-PCM heat exchanger providing latent energy storage of 0.5 kWh, this energy is deliver...

  13. Energy Savings Potential and Research, Development, & Demonstration Opportunities for Residential Building Heating, Ventilation, and Air Conditioning Systems

    Energy Technology Data Exchange (ETDEWEB)

    Goetzler, William [Navigant Consulting, Inc., Burlington, MA (United States); Zogg, Robert [Navigant Consulting, Inc., Burlington, MA (United States); Young, Jim [Navigant Consulting, Inc., Burlington, MA (United States); Schmidt, Justin [Navigant Consulting, Inc., Burlington, MA (United States)

    2012-10-01

    This report is an assessment of 135 different heating, ventilation, and air-conditioning (HVAC) technologies for U.S. residential buildings to identify and provide analysis on 19 priority technology options in various stages of development. The analyses include an estimation of technical energy-savings potential, descriptions of technical maturity, descriptions of non-energy benefits, descriptions of current barriers for market adoption, and descriptions of the technology's applicability to different building or HVAC equipment types. From these technology descriptions, are suggestions for potential research, development and demonstration (RD&D) initiatives that would support further development of the priority technology options.

  14. DNA accumulation on ventilation system filters in university buildings in Singapore.

    Directory of Open Access Journals (Sweden)

    Irvan Luhung

    Full Text Available Biological particles deposit on air handling system filters as they process air. This study reports and interprets abundance and diversity information regarding biomass accumulation on ordinarily used filters acquired from several locations in a university environment.DNA-based analysis was applied both to quantify (via DNA fluorometry and qPCR and to characterize (via high-throughput sequencing the microbial material on filters, which mainly processed recirculated indoor air. Results were interpreted in relation to building occupancy and ventilation system operational parameters.Based on accumulated biomass, average DNA concentrations per AHU filter surface area across nine indoor locations after twelve weeks of filter use were in the respective ranges 1.1 to 41 ng per cm2 for total DNA, 0.02 to 3.3 ng per cm2 for bacterial DNA and 0.2 to 2.0 ng DNA per cm2 for fungal DNA. The most abundant genera detected on the AHU filter samples were Clostridium, Streptophyta, Bacillus, Acinetobacter and Ktedonobacter for bacteria and Aspergillus, Cladosporium, Nigrospora, Rigidoporus and Lentinus for fungi. Conditional indoor airborne DNA concentrations (median (range were estimated to be 13 (2.6-107 pg/m3 for total DNA, 0.4 (0.05-8.4 pg/m3 for bacterial DNA and 2.3 (1.0-5.1 pg/m3 for fungal DNA.Conditional airborne concentrations and the relative abundances of selected groups of genera correlate well with occupancy level. Bacterial DNA was found to be more responsive than fungal DNA to differences in occupancy level and indoor environmental conditions.

  15. Dynamic model to tune a climate control algorithm in pig houses with natural ventilation

    NARCIS (Netherlands)

    Klooster, van 't C.E.; Bontsema, J.; Salomons, L.

    1995-01-01

    Algorithms for environmental control in livestock buildings have to be tuned for optimum response of actuators. For tuning, a simple, but dynamic, climate model for a pig house was formulated and validated to predict the
    environmental changes in a pig house with natural ventilation under varying

  16. Noxious gases in rabbit housing systems: effects of cross and longitudinal ventilation

    Directory of Open Access Journals (Sweden)

    Francesco da Borso

    2016-12-01

    Full Text Available Animal welfare is a matter of increasing interest due to ethical and economical worries regarding animal rights and the sustainability of meat production. Ammonia, carbon dioxide, and methane can be produced in the livestock buildings and, if not adequately controlled by ventilation, can be dangerous for animals and farmers. The aim of the present paper is to study the effects of different ventilation systems in rabbit buildings based on the temporal patterns and the spatial distribution of these noxious gases. The experimental measurements were conducted in two rabbit farms with genetically homogeneous animals subjected to the same diet. Two buildings with different forced ventilation layouts (cross ventilation - building A and longitudinal ventilation - building B were subjected to the monitoring of indoor environmental conditions (temperature, relative humidity, ammonia, carbon dioxide, methane over a whole year. In both the buildings, ventilation was adjusted automatically by means of electronic control units, which were controlled by temperature sensors, located at the centre of the buildings. Gas concentrations inside the buildings followed clearly defined sinusoidal patterns on a daily basis with the highest values reached in winter during the morning hours for ammonia and during the night hours for carbon dioxide and methane. In particular, ammonia revealed a maximum concentration of 30.7 mg m–3 in building A (cross ventilation and 12.9 mg m–3 in building B (longitudinal ventilation, whereas the minimum values were 6.0 and 4.2 mg m–3, in building A and B, respectively. As a consequence, daily mean concentrations of noxious gases, solely could not be considered representative of the actual conditions of air quality in the buildings. The airflow direction clearly influenced the spatial concentration of ammonia, which showed different patterns in the two buildings. In building A, the highest ammonia concentration was in a diffuse

  17. Appropriate Ventilation Solutions For The Iconographic Buildings From The Fifties - A Cross Disciplinary Investigation

    DEFF Research Database (Denmark)

    Vestergaard, Inge; Blyt, Henrik Jean

    2016-01-01

    : this integrated working methodology develops new renovation processes. Based on both quantitative measurements and on qualitative judgements the cases are analysed comparatively. Parameters such as ventilation solutions in facades are discussed as architectural consequence and value. User interviews will also...

  18. Methodology Applied to the Evaluation of Natural Ventilation in Residential Building Retrofits: A Case Study

    National Research Council Canada - National Science Library

    Alberto Meiss; Miguel A Padilla-Marcos; Jesús Feijó-Muñoz

    2017-01-01

    The primary objective of this paper is to present the use of a steady model that is able to qualify and quantify available natural ventilation flows applied to the energy retrofitting of urban residential districts...

  19. Quantifying the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building.

    Science.gov (United States)

    Tong, Zheming; Chen, Yujiao; Malkawi, Ali; Adamkiewicz, Gary; Spengler, John D

    2016-01-01

    Improper natural ventilation practices may deteriorate indoor air quality when in close proximity to roadways, although the intention is often to reduce energy consumption. In this study, we employed a CFD-based air quality model to quantify the impact of traffic-related air pollution on the indoor air quality of a naturally ventilated building. Our study found that the building envelope restricts dispersion and dilution of particulate matter. The indoor concentration in the baseline condition located 10m away from the roadway is roughly 16-21% greater than that at the edge of the roadway. The indoor flow recirculation creates a well-mixed zone with little variation in fine particle concentration (i.e., 253nm). For ultrafine particles (indoors with increasing distance from the road is observed due to Brownian and turbulent diffusion. In addition, the indoor concentration strongly depends on the distance between the roadway and building, particle size, wind condition, and window size and location. A break-even point is observed at D'~2.1 (normalized distance from the roadway by the width of the road). The indoor particle concentration is greater than that at the highway where D'air intakes are important to the indoor air quality of existing buildings adjacent to roadways. Copyright © 2016 Elsevier Ltd. All rights reserved.

  20. Numerical analysis of the potential of using light radiant ceilings in combination with diffuse ventilation to achieve thermal comfort in NZEB buildings

    DEFF Research Database (Denmark)

    Krusaa, Marie Rugholm; Hviid, Christian Anker; Kolarik, Jakub

    Renewable energy resources for heating and cooling of buildings have temperatures close to room temperature and therefore a limited convertibility potential, i.e. they are of low value. To exploit low-valued energy sources Low Temperature Heating and High Temperature Cooling (LTH-HTC) systems must...... ceiling panels. These panels make it possible to combine the heating/cooling ceiling with the diffuse ventilation method. The diffuse ventilation method or leak ventilation use larger surfaces to provide air into the room instead of diffusers. An office building is investigated an analysed on an annual...... basis in the dynamic building simulation tool IDA Indoor Climate and Energy (IDA ICE). The office building contains both offices and meeting rooms. Worst-case scenarios are investigated in the office building considering heat gains, solar gains and the temperature offset between supply water temperature...

  1. Experimental and Numerical Investigation of the Tracer Gas Methodology in the Case of a Naturally Cross-Ventilated Building

    DEFF Research Database (Denmark)

    Nikolopoulos, Nikos; Nikolopoulos, Aristeidis; Larsen, Tine Steen

    2012-01-01

    in this area of scientific research is provided, using the numerical predictions as a reference. It is concluded that velocity measurements in the inlet window are of high accuracy when the flow in this region has a steady character, whilst the accuracy of the tracer gas methodology depends significantly......The paper presents the investigation of a naturally cross – ventilated building using both experimental and numerical methods with the parameters being the free-stream and the incidence angle of the wind to the openings of the building. The experimental methodology calculates the air change rate......, focusing on the time dependent character of the induced flow field. The numerical results are compared with corresponding experimental data for the three aforementioned experimental methodologies in the case of a full scale building inside a wind-tunnel. The numerical investigation reveals that for large...

  2. To Investigate the Influence of Building Envelope and Natural Ventilation on Thermal Heat Balance in Office Buildings in Warm and Humid Climate

    Science.gov (United States)

    Kini, Pradeep G.; Garg, Naresh Kumar; Kamath, Kiran

    2017-07-01

    India’s commercial building sector is witnessing robust growth. India continues to be a key growth market among global corporates and this is reflective in the steady growth in demand for prime office space. A recent trend that has been noted is the increase in demand for office spaces not just in major cities but also in smaller tier II and Tier III cities. Growth in the commercial building sector projects a rising trend of energy intensive mechanical systems in office buildings in India. The air conditioning market in India is growing at 25% annually. This is due to the ever increasing demand to maintain thermal comfort in tropical regions. Air conditioning is one of the most energy intensive technologies which are used in buildings. As a result India is witnessing significant spike in energy demand and further widening the demand supply gap. Challenge in India is to identify passive measures in building envelope design in office buildings to reduce the cooling loads and conserve energy. This paper investigates the overall heat gain through building envelope components and natural ventilation in warm and humid climate region through experimental and simulation methods towards improved thermal environmental performance.

  3. Applied patent RFID systems for building reacting HEPA air ventilation system in hospital operation rooms.

    Science.gov (United States)

    Lin, Jesun; Pai, Jar-Yuan; Chen, Chih-Cheng

    2012-12-01

    RFID technology, an automatic identification and data capture technology to provide identification, tracing, security and so on, was widely applied to healthcare industry in these years. Employing HEPA ventilation system in hospital is a way to ensure healthful indoor air quality to protect patients and healthcare workers against hospital-acquired infections. However, the system consumes lots of electricity which cost a lot. This study aims to apply the RFID technology to offer a unique medical staff and patient identification, and reacting HEPA air ventilation system in order to reduce the cost, save energy and prevent the prevalence of hospital-acquired infection. The system, reacting HEPA air ventilation system, contains RFID tags (for medical staffs and patients), sensor, and reacting system which receives the information regarding the number of medical staff and the status of the surgery, and controls the air volume of the HEPA air ventilation system accordingly. A pilot program was carried out in a unit of operation rooms of a medical center with 1,500 beds located in central Taiwan from Jan to Aug 2010. The results found the air ventilation system was able to function much more efficiently with less energy consumed. Furthermore, the indoor air quality could still keep qualified and hospital-acquired infection or other occupational diseases could be prevented.

  4. Nonstationary heat and mass transfer in the multilayer building construction with ventilation channels

    Science.gov (United States)

    Kharkov, N. S.

    2017-11-01

    Results of numerical modeling of the coupled nonstationary heat and mass transfer problem under conditions of a convective flow in facade system of a three-layer concrete panel for two different constructions (with ventilation channels and without) are presented. The positive effect of ventilation channels on the energy and humidity regime over a period of 12 months is shown. Used new method of replacement a solid zone (requiring specification of porosity and material structure, what complicates process of convergence of the solution) on quasi-solid in form of a multicomponent mixture (with restrictions on convection and mass fractions).

  5. New Air Cleaning Strategies for Reduced Commercial Building Ventilation Energy ? FY11 Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Sidheswaran, Meera; Destaillats, Hugo; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William J.

    2011-10-31

    The research carried out in this project focuses on developing novel volatile organic compounds (VOCs) air cleaning technologies needed to enable energy-saving reductions in ventilation rates. we targeted a VOC air cleaning system that could enable a 50% reduction in ventilation rates. In a typical commercial HVAC system that provides a mixture of recirculated and outdoor air, a VOC air cleaner in the supply airstream must have a 15% to 20% VOC removal efficiency to counteract a 50% reduction in outdoor air supply.

  6. Design and operation of ventilation in low energy residences – A survey on code requirements and building reality from six European countries and China

    DEFF Research Database (Denmark)

    del Carmen Bocanegra-Yanez, Maria; Rojas, Gabriel; Zukowska-Tejsen, Daria

    One of the key objectives of the IEA Annex 68 research programme entitled “Indoor Air Quality Design and Control in Low Energy Residential Buildings” is to provide a generic guideline for the design and operation of ventilation in residential buildings. Modern and refurnished domestic buildings...... involved in the Annex. There were two main objectives, firstly, to describe and analyse a transition between actual requirements (national building codes and standards) and current practice. Secondly, to investigate current barriers and challenges regarding installation of mechanical ventilation...... resulting from poor construction, lack of commissioning and/or maintenance....

  7. Environmental control for confinement livestock housing

    Energy Technology Data Exchange (ETDEWEB)

    Jones, D.D.; Friday, W.H.; DeForest, S.S.

    1980-06-01

    Advantages and disadvantages of mechanical ventilation systems for livestock housing are discussed. Various principles involved in environmental control are reviewed. The design, operation, maintenance, and management of the equipment needed for environmental control are discussed. (JGB)

  8. Contribution to the study of hybrid ventilation system effectiveness in office and educational buildings; Contribution a l'etude de l'efficacite des systemes de ventilation hybride dans les batiments du secteur tertiaire

    Energy Technology Data Exchange (ETDEWEB)

    Cron, F.

    2004-06-15

    This study is part of the International Energy Agency Annex 35, 'Hybrid Ventilation in New and Retro-fitted Office Buildings', also called the HybVent Project. It presents the numerical analyses of a number of hybrid ventilation systems and their potential for several buildings in relation to local climate characteristics. The first part of this work reviews the state-of-the-art of existing ventilation systems and details the principles, expectations and features of hybrid ventilation systems. This first section also examines some examples of hybrid systems extracted from the collection of Annex 35 case studies. A comprehensive bibliography of numerical tools available for this type of analysis is given in the second section. The numerical models for building simulation and the object-oriented environment used to develop our simulation tool are presented in this section as well. Two single-zone studies undertaken in this project are reported in the third section. The first study concerns an experimental cell simulation. Numerical results are compared to experimental data to validate the use of the simulation tool developed. The second single-zone study predicts the potential of a specific hybrid ventilation system in a typical classroom, given climatic conditions. Finally, the last section presents a more complete study - a multi-zone study of the Tonga school, an Annex 35 case study located in Sweden. Three rooms were modelled initially to compare numerical results to experimental data and then to analyse the performance of the existing hybrid ventilation system and two other systems. This final study was completed for three European cities with very different climates. The overall analysis of the potential of the hybrid ventilation systems considered and the perspective for future work are outlined in the conclusion. (author)

  9. Design Principles for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system -Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and - principles are discussed and illustrated by four building examples....

  10. Evaluation of Heating, Ventilation, and Air conditioning (HVAC System Performance in an Administrative Building in Tehran (Iran

    Directory of Open Access Journals (Sweden)

    H. Mari Oriyad

    2014-09-01

    Full Text Available Introduction: One of the factors influencing on indoor air quality of the buildings is performance of HVAC (heating, ventilation, and air conditioning systems. These systems supply clean and odorless air, with temperature, humidity, and air velocity within comfort ranges for the residents. The aim of this study was to evaluate performance HVAC system in an administrative building in Tehran. .Material and Method: A questionnaire, developed in their research was used to assess the building occupants’ perception about the performance of HVAC system. To evaluate the performance of HVAC systems, air velocities were measured in the diffusers using a thermal anemometer. Moreover, CO2 concentration, air temperature and relative humidity were measured in the whole floors of the building. Air distribution inside the building was evaluated using smoke test. .Results: Most of the studied people complained about the direction of airflow, thermal conditions and cigarette odor. The highest level of carbon dioxide was measured at 930 ppm inside the restaurant. The maximum and minimum air temperatures and relative humidity were measured 28.3-13.8° C and 28.4-23% respectively. Smoke test showed that the air distribution/direction wasn’t suitable in one third of air diffusers. .Conclusion: Improper air distribution / direction was the main problem with the studied HVAC system which could be corrected by adjusting and balancing of the system.

  11. Feedback effect of human physical and psychological adaption on time period of thermal adaption in naturally ventilated building

    DEFF Research Database (Denmark)

    liu, weiwei; Huangfu, Hao; Xiong, Jing

    2014-01-01

    This study proposed a method to determine time period of thermal adaption for occupants in naturally ventilated building, and analyzed the synergistic and separate feedback effect of the physical and psychological adaption modes on the time period of thermal adaption. Using the method, the values...... indicated that the psychological adaption mode can speed up the process of thermal adaption to the variation in the outdoor climate condition. This study presented a new insight into the feedback from the thermal adaption modes to occupant thermal comfort.......This study proposed a method to determine time period of thermal adaption for occupants in naturally ventilated building, and analyzed the synergistic and separate feedback effect of the physical and psychological adaption modes on the time period of thermal adaption. Using the method, the values......, under the synergistic feedback effect of the physical and psychological adaption modes. The time period of thermal adaption increased to 13 days, if only the feedback effect of the physical adaption mode was accounted for. The difference between the two values of the time period of thermal adaption...

  12. Computational Fluid Dynamics Study on the Influence of Airflow Patterns on Carbon Dioxide Distribution in a Scaled Livestock Building

    DEFF Research Database (Denmark)

    Rong, Li; Nielsen, Peter V.; Tong, Guohong

    2008-01-01

    has been applied to simulate the contaminant distribution. Experiments of tracer gas concentration distribution in the chamber are performed at Air Physic Lab of Aarhus University to validate CFD software. Simulation results and measurements show that ventilation rates and airflow patterns have...

  13. Building envelope design for renewal of air by natural ventilation in moderate climates. Proposition of a designing methodology; Conception des enveloppes de batiments pour le renouvellement d'air par ventilation naturelle en climats temperes. Proposition d'une methodologie de conception

    Energy Technology Data Exchange (ETDEWEB)

    Mansouri, Y.

    2003-12-01

    The subject of this research is to produce methods and methodological tools for the architects to support the integration of natural ventilation systems in the building envelope design. Our research is situated to the interface between the architectural practice and the physical research on natural ventilation. We are interested in phenomena that can influence or force the strategy of ventilation. A morphological analysis of naturally ventilated buildings concerning the integration modes of natural ventilation systems is done permitting US to propose a typology and a topology of ventilation systems. We define criteria in relation to the thermal comfort, to the quality of air and the economy of energy to assess air renewal techniques. In complement of the sizing tool, we elaborate a methodology of conception for the integration of passives ventilation systems. Design guidelines permit US to conclude on an effective natural ventilation system which is well adapted to collective habitat. (author)

  14. A study of interunit dispersion around multistory buildings with single-sided ventilation under different wind directions

    Science.gov (United States)

    Ai, Z. T.; Mak, C. M.

    2014-05-01

    This study examines the interunit dispersion characteristics in and around multistory buildings under wind-induced single-sided ventilation conditions using computational fluid dynamics (CFD) method, under the hypothesis that infectious respiratory aerosols exhausted from a unit can reenter into another unit in a same building through opened windows. The effect of balconies on the interunit dispersion pattern is considered. The RNG k - ɛ model and the two-layer near-wall model are employed to establish the coupled indoor and outdoor airflow field, and the tracer gas technique is adopted to simulate pollutant dispersion. Reentry ratios from each unit to other units under prevailing wind directions are quantified and the possible interunit dispersion routes are then revealed. It is found that many reentry ratios appear to reach around 10.0%, suggesting that the interunit dispersion is an important pollutant transmission route. The interunit dispersion pattern is highly dependent on the incident wind direction and the fact whether the building has protrusive envelope features. On average, the strongest dispersion occurs on the windward wall of the buildings under oblique wind direction, owing to high ACH (air change per hour) values and unidirectional spread routes. Except under a normal incident wind, the presence of balconies intensifies the interunit dispersion by forming dispersion channels to increase the reentry ratios.

  15. Multifamily Ventilation Retrofit Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Ueno, K.; Lstiburek, J.; Bergey, D.

    2012-12-01

    In multifamily buildings, central ventilation systems often have poor performance, overventilating some portions of the building (causing excess energy use), while simultaneously underventilating other portions (causing diminished indoor air quality). BSC and Innova Services Corporation performed a series of field tests at a mid-rise test building undergoing a major energy audit and retrofit, which included ventilation system upgrades.

  16. A method for evaluating the problem complex of choosing the ventilation system for a new building

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2007-01-01

    for evaluating the performance of a ventilation system in the design proces by treating quantifiable and non-quantifiable datasets together. The method is based on general morphological analysis and applies cross-consistency assessment for reducing the problem complex, thus treating the multi......-dimensionality, the uncertainty and the subjectivity that arises in the design proces on a sound methodological and scientific basis. Through a distance analysis of the shared parameter values the solution scenarios may be plotted relative to each other, hence providing the designer with an illustrated ‘space of solutions...

  17. Personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  18. Particle deposition from turbulent flow: Review of published research and its applicability to ventilation ducts in commercial buildings

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark R.; Nazaroff, William W.

    2002-06-01

    This report reviews published experimental and theoretical investigations of particle deposition from turbulent flows and considers the applicability of this body of work to the specific case of particle deposition from flows in the ducts of heating, ventilating and air conditioning (HVAC) systems. Particle deposition can detrimentally affect the performance of HVAC systems and it influences the exposure of building occupants to a variety of air pollutants. The first section of this report describes the types of HVAC systems under consideration and discusses the components, materials and operating parameters commonly found in these systems. The second section reviews published experimental investigations of particle deposition rates from turbulent flows and considers the ramifications of the experimental evidence with respect to HVAC ducts. The third section considers the structure of turbulent airflows in ventilation ducts with a particular emphasis on turbulence investigations that have been used as a basis for particle deposition models. The final section reviews published literature on predicting particle deposition rates from turbulent flows.

  19. Limiting the Temperatures in Naturally Ventilated Buildings in Warm Climates. Building Research Establishment Current Paper 7/74.

    Science.gov (United States)

    Petherbridge, P.

    Formulas used in the calculation of cooling loads and indoor temperatures are employed to demonstrate the influence of various building parameters--such as thermal transmittance (U-value), solar absorptivity, and thermal storage--on the indoor thermal environment. The analysis leads to guidance on ways of limiting temperatures in naturally…

  20. Decommissioning of Active Ventilation Systems in a Nuclear R and D Facility to Prepare for Building Demolition (Whiteshell Laboratories Decommissioning Project, Canada) - 13073

    Energy Technology Data Exchange (ETDEWEB)

    Wilcox, Brian; May, Doug; Howlett, Don; Bilinsky, Dennis [Atomic Energy of Canada Limited, Ara Mooradian Way, Pinawa, Manitoba (Canada)

    2013-07-01

    Whiteshell Laboratories (WL) is a nuclear research establishment owned by the Canadian government and operated by Atomic Energy of Canada Limited (AECL) since the early 1960's. WL is currently under a decommissioning license and the mandate is to remediate the nuclear legacy liabilities in a safe and cost effective manner. The WL Project is the first major nuclear decommissioning project in Canada. A major initiative underway is to decommission and demolish the main R and D Laboratory complex. The Building 300 R and D complex was constructed to accommodate laboratories and offices which were mainly used for research and development associated with organic-cooled reactors, nuclear fuel waste management, reactor safety, advanced fuel cycles and other applications of nuclear energy. Building 300 is a three storey structure of approximately 16,000 m{sup 2}. In order to proceed with building demolition, the contaminated systems inside the building have to be characterized, removed, and the waste managed. There is a significant focus on volume reduction of radioactive waste for the WL project. The active ventilation system is one of the significant contaminated systems in Building 300 that requires decommissioning and removal. The active ventilation system was designed to manage hazardous fumes and radioactivity from ventilation devices (e.g., fume hoods, snorkels and glove boxes) and to prevent the escape of airborne hazardous material outside of the laboratory boundary in the event of an upset condition. The system includes over 200 ventilation devices and 32 active exhaust fan units and high efficiency particulate air (HEPA) filters. The strategy to remove the ventilation system was to work from the laboratory end back to the fan/filter system. Each ventilation duct was radiologically characterized. Fogging was used to minimize loose contamination. Sections of the duct were removed by various cutting methods and bagged for temporary storage prior to disposition

  1. Effects of animal activity and air temperature on methane and ammonia emissions from a naturally ventilated building for dairy cows

    Science.gov (United States)

    Ngwabie, N. M.; Jeppsson, K.-H.; Gustafsson, G.; Nimmermark, S.

    2011-12-01

    Knowledge of how different factors affect gas emissions from animal buildings can be useful for emission prediction purposes and for the improvement of emission abatement techniques. In this study, the effects of dairy cow activity and indoor air temperature on gas emissions were examined. The concentrations of CH 4, NH 3, CO 2 and N 2O inside and outside a dairy cow building were measured continuously between February and May together with animal activity and air temperature. The building was naturally ventilated and had a solid concrete floor which sloped towards a central urine gutter. Manure was scraped from the floor once every hour in the daytime and once every second hour at night into a partly covered indoor pit which was emptied daily at 6 a.m. and at 5 p.m. Gas emissions were calculated from the measured gas concentrations and ventilation rates estimated by the CO 2 balance method. The animal activity and emission rates of CH 4 and NH 3 showed significant diurnal variations with two peaks which were probably related to the feeding routine. On an average day, CH 4 emissions ranged from 7 to 15 g LU -1 h -1 and NH 3 emissions ranged from 0.4 to 1.5 g LU -1 h -1 (1 LU = 500 kg animal weight). Mean emissions of CH 4 and NH 3 were 10.8 g LU -1 h -1 and 0.81 g LU -1 h -1, respectively. The NH 3 emissions were comparable to emissions from tied stall buildings and represented a 4% loss in manure nitrogen. At moderate levels, temperature seems to affect the behaviour of dairy cows and in this study where the daily indoor air temperature ranged from about 5 up to about 20 °C, the daily activity of the cows decreased with increasing indoor air temperature ( r = -0.78). Results suggest that enteric fermentation is the main source of CH 4 emissions from systems of the type in this study, while NH 3 is mainly emitted from the manure. Daily CH 4 emissions increased significantly with the activity of the cows ( r = 0.61) while daily NH 3 emissions increased

  2. Wind-induced single-sided natural ventilation in buildings near a long street canyon: CFD evaluation of street configuration and envelope design

    DEFF Research Database (Denmark)

    Ai, Z.T.; Mak, C.M.

    2018-01-01

    an urban context, this study investigates the wind-induced single-sided natural ventilation in buildings near a long street canyon under a perpendicular wind direction using CFD method. Four aspect ratios (AR) of the street canyon, from 1.0, 2.0, 4.0 to 6.0, are investigated to examine the influence...

  3. Building ventilation: A pressure airflow model computer generation and elements of validation

    CERN Document Server

    Boyer, H; Adelard, L; Mara, T A

    2012-01-01

    The calculation of airflows is of great importance for detailed building thermal simulation computer codes, these airflows most frequently constituting an important thermal coupling between the building and the outside on one hand, and the different thermal zones on the other. The driving effects of air movement, which are the wind and the thermal buoyancy, are briefly outlined and we look closely at their coupling in the case of buildings, by exploring the difficulties associated with large openings. Some numerical problems tied to the resolving of the non-linear system established are also covered. Part of a detailled simulation software (CODYRUN), the numerical implementation of this airflow model is explained, insisting on data organization and processing allowing the calculation of the airflows. Comparisons are then made between the model results and in one hand analytical expressions and in another and experimental measurements in case of a collective dwelling.

  4. Investigation of the Indoor Environment in a Passive House Apartment Building Heated by Ventilation Air

    DEFF Research Database (Denmark)

    Lysholt Hansen, MathiasYoung Bok; Koulani, Chrysanthi Sofia; Peuhkuri, Ruut Hannele

    2014-01-01

    comfort and the performance of the air heating system and solar shading. Thermal comfort category B according to ISO 7730 was obtained in the building during field measurements, indicating that the air heating system was able to maintain comfort conditions in winter, when the outdoor temperature had been...... building project finished medio 2012. The design challenge was met with a concept of air heating that is individually controlled in every room. It also applies external solar shading. This study used indoor climate measurements and dynamic simulations in one of these apartment buildings to evaluate thermal...... unusual low for a longer period. The dynamic simulations also indicated that air heating during winter can provide a comfortable thermal environment. Dynamic simulations also demonstrated that during summer, apartments with automatic external solar screens had no serious overheating, whereas in apartments...

  5. The influence of opening windows and doors on the natural ventilation rate of a residential building

    Science.gov (United States)

    Increased building energy efficiency is important in reducing national energy use and greenhouse gas emissions. An analysis of air change rates due to door and window openings in a research test house located in a residential environment are presented. These data inform developme...

  6. Sick building syndrome and perceived indoor environment in relation to energy saving by reduced ventilation flow during heating season: a 1 year intervention study in dwellings.

    Science.gov (United States)

    Engvall, K; Wickman, P; Norbäck, D

    2005-04-01

    Ventilation in Scandinavian buildings is commonly performed by means of a constant flow ventilation fan. By using a regulated fan, it is possible to make a seasonal adjustment of outdoor ventilation flow. Energy saving can be achieved by reducing the mechanical ventilation flow during the heating season, when natural ventilation driven by temperature differences between outdoor and indoor is relatively high. This ventilation principle has been called 'seasonally adapted ventilation (SAV)'. The aim was to study if a 25-30% reduction of outdoor ventilation flow during heating season influenced sick building syndrome (SBS) and the perception of the indoor environment. This was done in a 1-year cross-over intervention study in 44 subjects in a multi-family building. During the first heating season (November to April), one part of the building (A) got a reduced flow during the heating season [0.4-0.5 air exchanges per hour (ACH)] while the other part (B) had constant flow (0.5-0.8 ACH). The next heating season, part A got constant flow, while part B got reduced ventilation flow. Reduced ventilation increased the relative air humidity by 1-3% in the living room (mean 30-37% RH), 1-5% in the bathroom (mean 48-58% RH) during heating season. The room temperature increased 0.1-0.3 degrees C (mean 20.7-21.6 degrees C), mean carbon dioxide (CO2) concentration in the bedroom increased from 920 to 980 p.p.m. at reduced flow. The indoor air quality was perceived as poorer at reduced outdoor airflow, both in the bedroom and in the apartment as a whole. There was a significant increase of stuffy odor (P = 0.05) at reduced outdoor airflow and the indoor air quality was perceived as poorer, both in the bedroom (P = 0.03) and in the apartment as a whole (P = 0.04). No significant influence on SBS symptoms or specific perceptions such as odors, draught, temperature, air dryness or stuffy air could be detected. In conclusion, reducing the ventilation flow in dwellings to a level below

  7. Healthy Zero Energy Buildings (HZEB) Program - Cross-Sectional Study of Contaminant Levels, Source, Strengths, and Ventilation Rates in Retail Stores

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R.; Sidheswaran, Meera; Cohn, Sebastian; Sullivan, Douglas P.; Fisk, William

    2014-02-01

    This field study measured ventilation rates and indoor air quality parameters in 21 visits to retail stores in California. The data was collected to guide the development of new, science-based commercial building ventilation rate standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. Data collection occurred between September 2011 and March 2013. Three types of stores participated in this study: grocery stores, furniture/hardware stores, and apparel stores. Ventilation rates and indoor air contaminant concentrations were measured on a weekday, typically between 9 am and 6 pm. Ventilation rates measured using a tracer gas decay method exceeded the minimum requirement of California’s Title 24 Standard in all but one store. Even though there was adequate ventilation according to Title 24, concentrations of formaldehyde, acetaldehyde, and acrolein exceeded the most stringent chronic health guidelines. Other indoor air contaminants measured included carbon dioxide (CO{sub 2}), carbon monoxide (CO), ozone (O{sub 3}), and particulate matter (PM). Concentrations of CO{sub 2} were kept low by adequate ventilation, and were assumed low also because the sampling occurred on a weekday when retail stores were less busy. CO concentrations were also low. The indoor-outdoor ratios of O{sub 3} showed that the first-order loss rate may vary by store trade types and also by ventilation mode (mechanical versus natural). Analysis of fine and ultrafine PM measurements showed that a substantial portion of the particle mass in grocery stores with cooking-related emissions was in particles less than 0.3 μm. Stores without cooking as an indoor source had PM size distributions that were more similar indoors and outdoors. The whole-building emission rates of volatile organic compounds (VOCs) and PM were estimated from the measured ventilation rates and indoor and outdoor contaminant concentrations. Mass balance models were

  8. Partial pit exhaust improves indoor air quality and effectiveness of air cleaning in livestock housing

    DEFF Research Database (Denmark)

    Zhang, Guoqiang; Bjerg, B.; Zong, C.

    2017-01-01

    approach to reduce emissions by combining an effective exhaust cleaner. The system can significantly improve the indoor air quality, because a considerable amount of the concentrated pollutants in the air are removed directly via PPAE. The pollutant removal via PPAE is influenced by airflow patterns......Ammonia and odor emissions from livestock production systems cause negative impact on atmospheric environment and local society. It is, therefore, important to develop cost-effective methods to reduce these emissions. Air cleaning technologies, including chemical and biological filters, have been...... proposed to clean the exhaust ventilation air from confined livestock buildings. However, it requires large capacity of the air cleaning unit for the total exhaust air and, consequently, results in high investment and operational costs of the livestock production system. Aiming at emission reduction...

  9. Characterization of ventilation ductwork in Building K-33 at the Oak Ridge K-25 Site

    Energy Technology Data Exchange (ETDEWEB)

    Mrochek, J.E.

    1992-05-01

    An extensive sampling and analysis program was initiated in September 1991 to characterize the ductwork of Building K-33, which is located at the Oak Ridge K-25 Site. This building, 32.4 acres under roof, contains nearly 3 miles of main plenums without considering the side laterals, which are extensive. A large number (i.e., 131) of hexane-moistened wipe samples were taken from within randomly selected locations in the 16 main plenums and the side lateral network. Samples were analyzed for polychlorinated biphenyls (PCBs), uranium, and technetium. These samples were augmented by 5 bulk material and 13 metal coupon samples that were subjected to TCLP (Toxicity Characteristic Leaching Procedure) analyses for arsenic, barium, cadmium, chromium, lead, nickel, selenium, silver, and mercury.

  10. Buoyancy-Driven Ventilation Generated by the Double-Skin Façade of a High-Rise Building in Tropical Climate: Case Study Bandung, Indonesia

    Directory of Open Access Journals (Sweden)

    Aziiz Akhlish Diinal

    2017-01-01

    Full Text Available High-rise buildings in tropical region is identical to the use of mechanical Air Conditioning in massive scale. Nevertheless, there is an encouragement to high-rise buildings to reduce its energy consumptions, since they consume quite large amount of energy. This challenge can be overcome with various of strategies, one of them, by means of reducing the cooling load of mechanical Air Conditioning in high-rise building. Prospects come from the modern tall building design strategies, for example the use of double-skin façade to give addition of building skin which could provide indoor temperature protection from outside. Double-skin façade system has continued to increase in buildings in a tropical region such as in Indonesia. However, there is another potential of double skin façade, which is the possibility to increase the buoyancy effect in the air gap between the skin and building envelope. The possibility needs to be studied in order to give a proper way in designing double-skin façade of a high-rise building, especially on Bandung-Indonesia tropical climate. This paper explores the potential of double-skin façade in driving the air inside the façade to generate natural ventilation for a high-rise building in Bandung climate condition. Two parameters are used in exploring the buoyancy force, the width of double-skin façade and the temperature of the skin façade. In general, double-skin façade of a high-rise building in tropical climate can generate buoyancy driven ventilation for the building, it relates strongly to the distance between of the double-skin façade and the building envelope.

  11. Diffuse ceiling ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen

    Diffuse ceiling ventilation is an innovative ventilation concept where the suspended ceiling serves as air diffuser to supply fresh air into the room. Compared with conventional ventilation systems, diffuse ceiling ventilation can significantly reduce or even eliminate draught risk due to the low...... momentum supply. In addition, this ventilation system uses a ceiling plenum to deliver air and requires less energy consumption for air transport than full-ducted systems. There is a growing interest in applying diffuse ceiling ventilation in offices and other commercial buildings due to the benefits from...... both thermal comfort and energy efficient aspects. The present study aims to characterize the air distribution and thermal comfort in the rooms with diffuse ceiling ventilation. Both the stand-alone ventilation system and its integration with a radiant ceiling system are investigated. This study also...

  12. Modulating ventilation - low cost VAV for office buildings. [Variable Air Volume]; Modulerende ventilation - low cost VAV til kontor-bygninger. Slutrapport

    Energy Technology Data Exchange (ETDEWEB)

    Hoej Christensen, A.; Olsen, Hans; Drivsholm, C.

    2012-02-15

    The report describes a concept for renovating older existing Constant Air Volume (CAV) ventilation systems to modulating low-cost Variable Air Volume (VAV) systems. The concept is based on the total ventilated area being divided into appropriate indoor climate zones, which can cover from one to several offices with similar climate needs. For this initial climate assessment two relatively ''simple'' tools were developed that can estimate the temperature level in one room from the ventilation airflow, heat loads, etc.: - BSimFast (24-hour mean temperature calculation according to SBI-196, 2000); - BSimLight (Temperature simulation based on Danvak Textbook of Heat and Climate Technology). The concept of 'one room' can also be extended to 'one zone' with appropriate assumptions. However, only one mean room temperature is calculated. The different climate zones were equipped with Halton HFB control unit at the air supply and exhaust side. The project the following feedback options were used: - HFB unit's damper opening degree (0 to 90 degrees); - HFB unit's current flow; - HFB unit's exhaust temperature; and feedback from: - Frequency transformer (fan speed); - The central static duct pressure at the ventilation unit. In the project a control algorithm is developed that ensures a robust control of the entire ventilation system without adverse cyclic variations, based among other things on the exhaust temperature for each climate zone, and with the requirement that at least one throttle valve is always at least 80% open. It turned out that information on the current partial air volumes was necessary in addition to the individual throttle settings. Otherwise, a cyclic variations could not be controlled..Thus, it was the exhaust temperature from individual climate zones that defined the respective volumes of air. The concept was implemented on a complete CAV system and on part of a large CAV system, respectively. (LN)

  13. The ability of hospital ventilation systems to filter Aspergillus and other fungi following a building implosion.

    Science.gov (United States)

    Srinivasan, Arjun; Beck, Christopher; Buckley, Timothy; Geyh, Allison; Bova, Greg; Merz, William; Perl, Trish M

    2002-09-01

    To assess the ability of hospital air handling systems to filter Aspergillus, other fungi, and particles following the implosion of an adjacent building; to measure the quantity and persistence of airborne fungi and particles at varying distances during a building implosion; and to determine whether manipulating air systems based on the movement of the dust cloud would be an effective strategy for managing the impact of the implosion. Air sampling study. A 976-bed teaching hospital in Baltimore, Maryland. Single-stage impactors and particle counters were placed at outdoor sites 100, 200, and 400 m from the implosion and in five locations in the hospital: two oncology floors, the human immunodeficiency virus unit, the cardiac surgical intensive care unit, and the ophthalmology unit. Air handling systems would operate normally unless the cloud approached the hospital. Wind carried the bulk of the cloud away from the hospital. Aspergillus counts rose more than tenfold at outdoor locations up to 200 m from the implosion, but did not increase at 400 m. Total fungal counts rose more than sixfold at 100 and 200 m and twofold at 400 m. Similar to Aspergillus, particle counts rose several-fold following the implosion at 100 and 200 m, but did not rise at 400 m. No increases in any fungi or particles were measured at indoor locations. Reacting to the movement of the cloud was effective, because normal operation of the hospital air handling systems was able to accommodate the modest increase in Aspergillus, other fungi, and particles generated by the implosion. Aspergillus measurements were paralleled by particle counts.

  14. Healthy Zero Energy Buildings (HZEB) Program Interim Report on Cross Sectional Study of Contaminant Levels, Source Strengths, and Ventilation Rates in Retail Stores

    Energy Technology Data Exchange (ETDEWEB)

    Chan, Wanyu R. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sidheswaran, Meera [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); sullivan, Douglas [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Cohn, Sebastian [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Fisk, William J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-11-05

    The HZEB research program aims to generate information needed to develop new science-based commercial building ventilation rate (VR) standards that balance the dual objectives of increasing energy efficiency and maintaining acceptable indoor air quality. This interim report describes the preliminary results from one HZEB field study on retail stores. The primary purpose of this study is to estimate the whole-building source strengths of contaminant of concerns (COCs). This information is needed to determine the VRs necessary to maintain indoor concentrations of COCs below applicable health guidelines.The goal of this study is to identify contaminants in retail stores that should be controlled via ventilation, and to determine the minimum VRs that would satisfy the occupant health and odor criteria.

  15. Design Principles for Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. ....... The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples....

  16. Design Principles for Natural and Hybrid Ventilation

    OpenAIRE

    Heiselberg, Per

    2000-01-01

    For many years mechanical and natural ventilation systems have developed separately. Naturally, the next step in this development is the development of ventilation concepts that utilize and combine the best features from each system to create a new type of ventilation system- Hybrid Ventilation. The hybrid ventilation concepts, design challenges and principles are discussed and illustrated by four building examples.

  17. Personalized ventilation.

    Science.gov (United States)

    Melikov, A K

    2004-01-01

    The thermal environment and air quality in buildings affects occupants' health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard to physiological and psychological response, clothing insulation, activity, air temperature and air movement preference, etc. Environmental conditions acceptable for most occupants in rooms may be achieved by providing each occupant with the possibility to generate and control his/her own preferred microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfill the above requirements. This paper reviews existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analyzed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice. Performance criteria are defined. Recommendations for design of PV that would be in compliance with the criteria are given. Future research needed on the topic is outlined. Personalized ventilation can improve occupants' comfort, decrease SBS symptoms and reduce the risk of transmission of contagion between occupants in comparison with total volume ventilation. However in order to perform efficiently in rooms in practice, the design (air distribution, control, etc.) has to be carefully considered together with type of occupant activity (occupancy rate, occupied density, etc.).

  18. What does the scientific literature tell us about the ventilation-health relationship in public and residential buildings?

    DEFF Research Database (Denmark)

    Carrer, Paolo; Wargocki, Pawel; Fanetti, Annaclara

    2015-01-01

    Objective of this paper is to examine whether the available epidemiological evidence provides information on the link between outdoor air ventilation rates and health, and whether it can be used for regulatory purposes when setting ventilation requirements for non-industrial built environments. E...

  19. Natural ventilation for new technoloy center building of Mercedes-Benz Maybach; Keine kuenstliche Beatmung - fuer den Mercedes-Benz Maybach im neuen Technologie-Zentrum

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    1998-11-01

    The buildings of the Mercedes-Benz technology centre at Sindelfingen are equipped with natural illumination and natural ventilation systems. This is achieved by daylighting and by circulation of fresh air. Temperature differences in the air flow are used for keeping a constant temperature level inside the buildings. [Deutsch] Im Technologie-Zentrum in Sindelfingen klimatisiert und beleuchtet Daimler-Benz die Gebaeude weitgehend auf eine natuerliche Art und Weise. Ermoeglicht wird dies durch Gebaeudefassaden, die Tageslicht blendfrei in die Tiefe der Raeume lenken, ferner durch die Zirkulation der Aussenluft, die vorhandene Temperaturdifferenzen fuer eine Vergleichmaessigung der Gebaeudetemperatur nutzbar macht. (orig.)

  20. Manchester Civil Justice Centre: Procuring and Managing an Institutional Building with a Mixed Mode Ventilation System—A Case for Post-Occupancy Evaluation

    Directory of Open Access Journals (Sweden)

    John Napier

    2013-04-01

    Full Text Available Manchester Civil Justice Centre is a striking contemporary 14 storey court building which has won awards for many different aspects of its design, construction and sustainability. From November 2002 to July 2005, the author was a key member of Denton Corker Marshall’s London project team having responsibility for key areas of design development, integration of technology and sustainable design including the East elevation’s “environmental veil”. This paper tracks the procurement of the building, describing its low energy features and their performance in practice. The paper reviews the low carbon elements of the design (daylight and natural ventilation systems in the context of similar buildings and the buildings operational performance. The building has a mixed mode ventilation system which is managed centrally; the paper describes the ongoing relationship between the Facilities Management and the building’s users and their expectations of comfort and offers an explanation as to why the building’s energy performance is not as good as predicted at design stage. A case is made that this building is a significant example of low energy design and would form a good example for a detailed Post Occupancy Evaluation. The energy performance of the building could be studied in more detail to encourage the users (judges, staff and the public to improve the building’s energy performance and to share knowledge within the construction industry. Institutional and commercial barriers to the more mainstream adoption of Post Occupancy Evaluation are discussed with respect to the Manchester Civil Justice Centre.

  1. Hybrid Ventilation Air Flow Process

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols

    The scope of this annex is therefore to obtain better knowledge of the use of hybrid ventilation technologies. The annex focus on development of control strategies for hybrid ventilation, on development of methods to predict hybrid ventilation performance in office buildings and on implementation...

  2. Environmental impact comparison of a ventilated and a non-ventilated building-integrated photovoltaic rooftop design in the Netherlands: Electricity output, energy payback time, and land claim

    NARCIS (Netherlands)

    Ritzen, M.J.; Vroon, Z.A.E.P.; Rovers, R.; Lupíšek, A.; Geurts, C.P.W.

    2017-01-01

    Building Integrated PV (BIPV) is considered as a key development for successful deployment of PV in the built environment. However, the effect of PV integration on environmental impact is not fully understood. In this study a single indicator for environmental impact assessment of BIPV is

  3. Predicting night-time natural ventilation in Stanford's Y2E2 building using an integral model in combination with a CFD model

    Science.gov (United States)

    Lamberti, Giacomo; Gorle', Catherine

    2016-11-01

    Natural ventilation can significantly reduce energy consumption in buildings, but the presence of uncertainty makes robust design a challenging task. We will discuss the prediction of the natural ventilation performance during a 4 hour night-flush in Stanford's Y2E2 building using a combination of two models with different levels of fidelity: an integral model that solves for the average air and thermal mass temperature and a CFD model, used to calculate discharge and heat transfer coefficients to update the integral model. Uncertainties are propagated using polynomial chaos expansion to compute the mean and 95% confidence intervals of the quantities of interest. Comparison with building measurements shows that, despite a slightly to fast cooling rate, the measured air temperature is inside the 95% confidence interval predicted by the integral model. The use of information from the CFD model in the integral model reduces the maximum standard deviation of the volume-averaged air temperature by 20% when compared to using literature-based estimates for these quantities. The heat transfer coefficient resulting from the CFD model was found to be within the literature-based interval initially assumed for the integral model, but the discharge coefficients were found to be different.

  4. International Energy Agency Building Energy Simulation Test and Diagnostic Method for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST); Volume 1: Cases E100-E200

    Energy Technology Data Exchange (ETDEWEB)

    Neymark, J.; Judkoff, R.

    2002-01-01

    This report describes the Building Energy Simulation Test for Heating, Ventilating, and Air-Conditioning Equipment Models (HVAC BESTEST) project conducted by the Tool Evaluation and Improvement International Energy Agency (IEA) Experts Group. The group was composed of experts from the Solar Heating and Cooling (SHC) Programme, Task 22, Subtask A. The current test cases, E100-E200, represent the beginning of work on mechanical equipment test cases; additional cases that would expand the current test suite have been proposed for future development.

  5. Low home ventilation rate in combination with moldy odor from the building structure increase the risk for allergic symptoms in children.

    Science.gov (United States)

    Hägerhed-Engman, L; Sigsgaard, T; Samuelson, I; Sundell, J; Janson, S; Bornehag, C-G

    2009-06-01

    There are consistent findings on associations between asthma and allergy symptoms and residential mold and moisture. However, definitions of 'dampness' in studies are diverse because of differences in climate and building construction. Few studies have estimated mold problems inside the building structure by odor assessments. In a nested case-control study of 400 Swedish children, observations and measurements were performed in their homes by inspectors, and the children were examined by physicians for diagnoses of asthma, eczema, and rhinitis. In conclusion, we found an association between moldy odor along the skirting board and allergic symptoms among children, mainly rhinitis. No associations with any of the allergic symptoms were found for discoloured stains, 'floor dampness' or a general mold odor in the room. A moldy odor along the skirting board can be a proxy for hidden moisture problem inside the outer wall construction or in the foundation construction. There are indications that such dampness problems increase the risk for sensitization but the interpretation of data in respect of sensitization is difficult as about 80% of the children with rhinitis were sensitized. Furthermore, low ventilation rate in combination with moldy odor along the skirting board further increased the risk for three out of four studied outcomes, indicating that the ventilation rate is an effect modifier for indoor pollutants. This study showed that mold odor at the skirting board level is strongly associated with allergic symptoms among children. Such odor at that specific place can be seen as a proxy for some kind of hidden moisture or mold problem in the building structure, such as the foundation or wooden ground beam. In houses with odor along the skirting board, dismantling of the structure is required for an investigation of possible moisture damage, measurements, and choice of actions. In homes with low ventilation in combination with mold odor along the skirting board

  6. Design Procedure for Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Tjelflaat, Per Olaf

    Mechanical and natural ventilation systems have developed separately during many years. The natural next step in this development is development of ventilation concepts that utilises and combines the best features from each system into a new type of ventilation system - Hybrid Ventilation....... Buildings with hybrid ventilation often include other sustainable technologies and an energy optimisation requires an integrated approach in the design of the building and its mechanical systems. Therefore, the hybrid ventilation design procedure differs from the design procedure for conventional HVAC....... The first ideas on a design procedure for hybrid ventilation is presented and the different types of design methods, that is needed in different phases of the design process, is discussed....

  7. Laboratory study on the cooling effect of flash water evaporative cooling technology for ventilation and air-conditioning of buildings

    DEFF Research Database (Denmark)

    Fang, Lei; Yuan, Shu; Yang, Jianrong

    2016-01-01

    environments and the other simulated an air-conditioned indoor environment. The flash water evaporation cooling device was installed in the chamber that simulated indoor environment. The air from the chamber simulating outdoor environment was introduced into the cooling device and cooled by the flash water...... evaporation. Two outdoor summer climates were simulated in the study, i.e. the design summer climate of Las Vegas and the extreme summer climate of Copenhagen represented hot/dry and warm/dry climates. The results showed that the flash evaporative cooling technology, a simple and green cooling technology......This paper presents a simple cooling technology using flash water evaporation. The technology combines a water atomizer with a plate heat exchanger used for heat recovery of a ventilation system. It is mainly used to cool the ventilation airflow from outdoors and is particularly suitable to be used...

  8. On the association between building ventilation characteristics, some indoor environmental exposures, some allergic manifestations and subjective symptom reports

    Energy Technology Data Exchange (ETDEWEB)

    Sundell, J. (Karolinska Institute, Institute of Environmental Medicine, Stockholm (Sweden))

    1994-05-01

    The aims of the present thesis are (1) to assess the associations between ventilation characteristics of homes, house dust mite infestation and allergy among children; (2) to assess the association between ventilation characteristics and occurrence of reported SBS-related symptoms among office workers; (3) to analyze associations between reported SBS-related symptoms and the reported sensation of dryness and associations between the reported sensation of dryness and physical air humidity, room characteristics and chemical factors; and (4) to study changes in total volatile organic compounds (TVOC) or formaldehyde concentration from outdoor air to room air and to study the associations between SBS-related symptom reports and concentrations of TVOC and formaldehyde in room air. (au) (256 refs.)

  9. Building America Case Study: Energy Efficient Management of Mechanical Ventilation and Relative Humidity in Hot-Humid Climates, Cocoa, Florida

    Energy Technology Data Exchange (ETDEWEB)

    2017-01-01

    In hot and humid climates, it is challenging to energy-efficiently maintain indoor RH at acceptable levels while simultaneously providing required ventilation, particularly in high performance low cooling load homes. The fundamental problem with solely relying on fixed capacity central cooling systems to manage moisture during low sensible load periods is that they are oversized for cooler periods of the year despite being 'properly sized' for a very hot design cooling day. The primary goals of this project were to determine the impact of supplementing a central space conditioning system with 1) a supplemental dehumidifier and 2) a ductless mini-split on seasonal energy use and summer peak power use as well as the impact on thermal distribution and humidity control inside a completely furnished lab home that was continuously ventilated in accordance with ASHRAE 62.2-2013.

  10. Livestock Animal Displacement on Rural Tourism Destinations: Placing Livestock's “Pest” Role in the Background

    Directory of Open Access Journals (Sweden)

    Guorong Tang

    2017-07-01

    Full Text Available Rural tourism is becoming increasingly embedded in the livestock animal management in rural areas. Drawing on a multi-methods approach, this exploratory research shows how to construct the livestock animal displacement actor-networks. As is found, human actors (local governments, tourists, and local residents, non-human animal (livestock and quasi-object (human dwellings construct an interaction network in a structured way. The critical action route of livestock animal displacement demonstrated in this research is aimed to improve residents' participation willingness and further to change the local livestock feeding model and traditional dwelling by rural environment governance and rural tourism landscape consumption. Through the process of translation, problematization, interest, enrollment, mobilization and opposition, the livestock displacement actor-networks were constructed to build a heterogeneous network of the local government, tourists, local residents, livestock and human dwelling. The ultimate goal is to change the traditional human dwelling to a dis-dwelling; the most important thing is to promote residents’ participation willingness in the livestock displacement actor-networks. This article attempts to perform compelling exploratory research to elucidate the livestock displacement actor-networks in hope to provide a meaningful contribution to the epistemology and methodology of livestock management on rural tourism destination and open a new path for research on rural livestock-human relations.

  11. A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Logue, J. M.; Turner, W. J.N.; Walker, I. S.; Singer, B. C.

    2015-07-01

    Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector’s energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level.

  12. A simplified model for estimating population-scale energy impacts of building envelope air-tightening and mechanical ventilation retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Logue, Jennifer M. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Turner, William J. N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Trinity College Dublin, Dublin (Ireland); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Singer, Brett C. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2015-01-19

    Changing the air exchange rate of a home (the sum of the infiltration and mechanical ventilation airflow rates) affects the annual thermal conditioning energy. Large-scale changes to air exchange rates of the housing stock can significantly alter the residential sector's energy consumption. However, the complexity of existing residential energy models is a barrier to the accurate quantification of the impact of policy changes on a state or national level. The Incremental Ventilation Energy (IVE) model developed in this study combines the output of simple air exchange models with a limited set of housing characteristics to estimate the associated change in energy demand of homes. The IVE model was designed specifically to enable modellers to use existing databases of housing characteristics to determine the impact of ventilation policy change on a population scale. The IVE model estimates of energy change when applied to US homes with limited parameterisation are shown to be comparable to the estimates of a well-validated, complex residential energy model.

  13. Agroecology : integration with livestock

    OpenAIRE

    Tichit, Muriel; Lecompte, Philippe; Dumont, Bertrand

    2014-01-01

    Livestock systems are a large global asset contributing to food security and poverty alleviation, but livestock supply chains have major environmental impacts at global scale. The scientific literature on agroecology has not yet integrated livestock systems; only 5 percent of the indexed studies concerning agroecology deal with livestock. Following Dumont et al. (2013), we review five principles for integrating livestock systems within the agroecology debate: (i) adopting management practices...

  14. Ventilation rates and health

    DEFF Research Database (Denmark)

    Sundell, Jan; Levin, H; Nazaroff, W W

    2011-01-01

    The scientific literature through 2005 on the effects of ventilation rates on health in indoor environments has been reviewed by a multidisciplinary group. The group judged 27 papers published in peer-reviewed scientific journals as providing sufficient information on both ventilation rates...... and health effects to inform the relationship. Consistency was found across multiple investigations and different epidemiologic designs for different populations. Multiple health endpoints show similar relationships with ventilation rate. There is biological plausibility for an association of health outcomes...... studies of the relationship between ventilation rates and health, especially in diverse climates, in locations with polluted outdoor air and in buildings other than offices. PRACTICAL IMPLICATIONS: Ventilation with outdoor air plays an important role influencing human exposures to indoor pollutants...

  15. Displacement ventilation

    DEFF Research Database (Denmark)

    Kosonen, Risto; Melikov, Arsen Krikor; Mundt, Elisabeth

    The aim of this Guidebook is to give the state-of-the art knowledge of the displacement ventilation technology, and to simplify and improve the practical design procedure. The Guidebook discusses methods of total volume ventilation by mixing ventilation and displacement ventilation and it gives...... insights of the performance of the displacement ventilation. It also shows practical case studies in some typical applications and the latest research findings to create good local micro-climatic conditions....

  16. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    -cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...... in applying diffuse ceiling ventilation in offices and other commercial buildings because of the benefits from both thermal comfort and energy efficiency aspects. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation and the design...

  17. Low-energy mechanical ventilation

    DEFF Research Database (Denmark)

    Andersen, Claus Wessel; Hviid, Christian Anker

    2014-01-01

    and with as little energy consumption as 41.1 kWh/m2/year including heating and all building services with no use of renewable energy such as PVcells or solar heating. One of the key means of reaching the objectives was to implement mechanical ventilation with low pressure loss and therefore low energy consumption....... The project consists of two buildings, building one is 6 stories high, and building two is 4 stories high. The buildings have a gross area of 50,500 m2 including underground parking. The ventilation and indoor climate concept was to use mechanical ventilation together with mechanical cooling and fanassisted......, with an average of 1.1 kJ/m3. The yearly mean SFP based on estimated runtime is approx. 0.8 kJ/m3. The case shows the unlocked potential that lies within mechanical ventilation for nearzero energy consuming buildings....

  18. Comparison of a Constant Air Volume (CAV) and a Demand Controlled Ventilation (DCV) System in a Residential Building

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig; Nielsen, Toke Rammer; Topp, Claus

    2008-01-01

    hygroscopic properties on indoor climate and energy consumption was investigated for the two systems. Dynamic simulations of the studio apartment were carried out in the program WUFI+ with weather data from Copenhagen including outside temperature end relative humidity. For the non-hygroscopic case...... it was found that the energy consumption for heating and operating the ventilation system could be reduced by respectively 8.0% and 10.6 % in the case of DCV without negative impact on the indoor climate. Including the hygroscopic properties of the materials resulted in a reduction of the energy consumption...

  19. Apartment building built to passive-house standard with solar balanced ventilation system; Mehrfamilien-Passivhaus mit solarem Luftsystem. Lueftung/Luftheizung/WRG/Solarfassade an der Rychenbergstrasse, Winterthur - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Guetermann, A.

    2002-04-15

    This final report for the Swiss Federal Office of Energy (SFOE) deals with an apartment building in Winterthur, Switzerland, built to passive-house standards and equipped with a solar balanced ventilation system. The building and its convective solar facade are described, as are the fan-assisted, balanced ventilation systems used. The operation of the systems in winter, during transitional periods and in summer is discussed. Domestic hot water preparation is looked at. The energy balance of the building is examined, as is the economic viability of the energy systems. The building, its energy installations and the measurement concept used are considered in detail. Finally, the findings of the study are summarised and commented on.

  20. Impact of the atmospheric boundary layer profile on the ventilation of a cubic building with two large opposite openings

    OpenAIRE

    Bastide, Alain; Lucas, Franck; Boyer, Harry

    2014-01-01

    International audience; The aim of this paper is to show the influence of the atmospheric boundary layer profile on the distribution of velocity in a building having two large openings. The knowledge of the flow form inside a building is useful to define a thermal environment favourable with thermal comfort and good air quality. In computational fluid dynamics, several profiles of atmospheric boundary layer can be used like logarithmic profiles or power profiles. This paper shows the impact o...

  1. Modeling a Naturally Ventilated Double Skin Façade with a Building Thermal Simulation Program

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Kalyanova, Olena; Heiselberg, Per

    2008-01-01

    to predict. This is manly due to the very transient and complex air flow in the naturally ventilated double skin façade cavity. In this paper the modelling of the DSF using a thermal simulation program, BSim, is discussed. The simulations are based on the measured weather boundary conditions......The use of Double Skin Façade (DSF) has increased during the last decade. There are many reasons for this including e.g. aesthetics, sound insulation, improved indoor environment and energy savings. However, the influence on the indoor environment and energy consumption are very difficult......, and the simulation results are compared to the measurement results like energy consumption for cooling, air temperature, temperature gradient and mass flow rate in the DSF cavity, etc. Details about the measurements are reported in \\Kalyanova et al. 2008\\. The thermal simulation program does not at the moment...

  2. Modeling a Naturally Ventilated Double Skin Façade with a Building Thermal Simulation Program

    DEFF Research Database (Denmark)

    Jensen, Rasmus Lund; Kalyanova, Olena; Heiselberg, Per

    2008-01-01

    The use of Double Skin Façade (DSF) has increased during the last decade. There are many reasons for this including e.g. aesthetics, sound insulation, improved indoor environment and energy savings. However, the influence on the indoor environment and energy consumption are very difficult...... to predict. This is manly due to the very transient and complex air flow in the naturally ventilated double skin façade cavity. In this paper the modelling of the DSF using a thermal simulation program, BSim, is discussed. The simulations are based on the measured weather boundary conditions......, and the simulation results are compared to the measurement results like energy consumption for cooling, air temperature, temperature gradient and mass flow rate in the DSF cavity, etc. Details about the measurements are reported in \\Kalyanova et al. 2008\\. The thermal simulation program does not at the moment...

  3. Temperature and Humidity Control in Livestock Stables

    DEFF Research Database (Denmark)

    Hansen, Michael; Andersen, Palle; Nielsen, Kirsten M.

    2010-01-01

    The paper describes temperature and humidity control of a livestock stable. It is important to have a correct air flow pattern in the livestock stable in order to achieve proper temperature and humidity control as well as to avoid draught. In the investigated livestock stable the air flow...... is controlled using wall mounted ventilation flaps. In the paper an algorithm for air flow control is presented meeting the needs for temperature and humidity while taking the air flow pattern in consideration. To obtain simple and realisable controllers a model based control design method is applied....... In the design dynamic models for temperature and humidity are very important elements and effort is put into deriving and testing the models. It turns out that non-linearities are dominating in both models making feedback linearization the natural design method. The air controller as well as the temperature...

  4. Risk Factors in Heating, Ventilating, and Air-Conditioning Systemsfor Occupant Symptoms in U.S. Office Buildings: the EPA BASE Study

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, M.J.; Lei-Gomez, Q.; Mirer, A.; Seppanen, O.; Brunner, G.

    2006-10-01

    Nonspecific building-related symptoms among occupants of modern office buildings worldwide are common and may be associated with important reductions in work performance, but their etiology remains uncertain. Characteristics of heating, ventilating, and air-conditioning (HVAC) systems in office buildings that increase risk of indoor contaminants or reduce effectiveness of ventilation may cause adverse exposures and subsequent increase in these symptoms among occupants. We analyzed data collected by the U.S. EPA from a representative sample of 100 large U.S. office buildings--the Building Assessment and Survey Evaluation (BASE) study--using multivariate logistic regression models with generalized estimating equations adjusted for potential personal and building confounders. We estimated odds ratios (ORs) and 95% confidence intervals (CIs) for associations between seven building-related symptom outcomes and selected HVAC system characteristics. Among factors of HVAC design or configuration: Outdoor air intakes less than 60 m above the ground were associated with approximately doubled odds of most symptoms assessed. Sealed (non-operable) windows were associated with increases in skin and eye symptoms (ORs= 1.9, 1.3, respectively). Outdoor air intake without an intake fan was associated with an increase in eye symptoms (OR=1.7). Local cooling coils were associated with increased headache (OR=1.5). Among factors of HVAC condition, maintenance, or operation: the presence of humidification systems in good condition was associated with an increase in headache (OR=1.4), whereas the presence of humidification systems in poor condition was associated with increases in fatigue/difficulty concentrating, as well as upper respiratory symptoms (ORs=1.8, 1.5). No regularly scheduled inspections for HVAC components was associated with increased eye symptoms, cough and upper respiratory symptoms (ORs=2.2, 1.6, 1.5). Less frequent cleaning of cooling coils or drip pans was associated

  5. Equivalence in Ventilation and Indoor Air Quality

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max; Walker, Iain; Logue, Jennifer

    2011-08-01

    We ventilate buildings to provide acceptable indoor air quality (IAQ). Ventilation standards (such as American Society of Heating, Refrigerating, and Air-Conditioning Enginners [ASHRAE] Standard 62) specify minimum ventilation rates without taking into account the impact of those rates on IAQ. Innovative ventilation management is often a desirable element of reducing energy consumption or improving IAQ or comfort. Variable ventilation is one innovative strategy. To use variable ventilation in a way that meets standards, it is necessary to have a method for determining equivalence in terms of either ventilation or indoor air quality. This study develops methods to calculate either equivalent ventilation or equivalent IAQ. We demonstrate that equivalent ventilation can be used as the basis for dynamic ventilation control, reducing peak load and infiltration of outdoor contaminants. We also show that equivalent IAQ could allow some contaminants to exceed current standards if other contaminants are more stringently controlled.

  6. Effects of ventilation rate per person and per floor area on perceived air quality, sick building syndrome symptoms, and decision-making.

    Science.gov (United States)

    Maddalena, R; Mendell, M J; Eliseeva, K; Chan, W R; Sullivan, D P; Russell, M; Satish, U; Fisk, W J

    2015-08-01

    Ventilation rates (VRs) in buildings must adequately control indoor levels of pollutants; however, VRs are constrained by the energy costs. Experiments in a simulated office assessed the effects of VR per occupant on perceived air quality (PAQ), Sick Building Syndrome (SBS) symptoms, and decision-making performance. A parallel set of experiments assessed the effects of VR per unit floor area on the same outcomes. Sixteen blinded healthy young adult subjects participated in each study. Each exposure lasted four hours and each subject experienced two conditions in a within-subject study design. The order of presentation of test conditions, day of testing, and gender were balanced. Temperature, relative humidity, VRs, and concentrations of pollutants were monitored. Online surveys assessed PAQ and SBS symptoms and a validated computer-based tool measured decision-making performance. Neither changing the VR per person nor changing the VR per floor area, had consistent statistically significant effects on PAQ or SBS symptoms. However, reductions in either occupant-based VR or floor-area-based VR had a significant and independent negative impact on most decision-making measures. These results indicate that the changes in VR employed in the study influence performance of healthy young adults even when PAQ and SBS symptoms are unaffected. The study results indicate the importance of avoiding low VRs per person and low VRs per floor area to minimize decrements in cognitive performance. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  7. CFD Simulation of Spread Risks of Infectious Disease due to Interactive Wind and Ventilation Airflows via Window Openings in High-Rise Buildings

    Science.gov (United States)

    Niu, J. L.; Gao, N. P.

    2010-05-01

    One of the concerns is that there may exist multiple infectious disease transmission routes across households in high-rise residential buildings, one of which is the natural ventilative airflow through open windows between flats, caused by buoyancy effects. This study presents the modeling of this cascade effect using computational fluid dynamics (CFD) technique. It is found that the presence of the pollutants generated in the lower floor is generally lower in the immediate upper floor by two orders of magnitude, but the risk of infection calculated by the Wells-Riley equation is only around one order of magnitude lower. It is found that, with single-side open-window conditions, wind blowing perpendicularly to the building may either reinforce or suppress the upward transport, depending on the wind speed. High-speed winds can restrain the convective transfer of heat and mass between flats, functioning like an air curtain. Despite the complexities of the air flow involved, it is clear that this transmission route should be taken into account in infection control.

  8. CFD and Ventilation Research

    DEFF Research Database (Denmark)

    Li, Y.; Nielsen, Peter V.

    2011-01-01

    There has been a rapid growth of scientific literature on the application of computational fluid dynamics (CFD) in the research of ventilation and indoor air science. With a 1000–10,000 times increase in computer hardware capability in the past 20 years, CFD has become an integral part...... of scientific research and engineering development of complex air distribution and ventilation systems in buildings. This review discusses the major and specific challenges of CFD in terms of turbulence modelling, numerical approximation, and boundary conditions relevant to building ventilation. We emphasize...... the growing need for CFD verification and validation, suggest on-going needs for analytical and experimental methods to support the numerical solutions, and discuss the growing capacity of CFD in opening up new research areas. We suggest that CFD has not become a replacement for experiment and theoretical...

  9. Benefits of the use of thermal insulation in a naturally ventilated residential building in Brazilian temperate climate

    OpenAIRE

    Vinícius Linczuk; Fernando Simon Westphal

    2016-01-01

    The use of thermal insulation is not a common practice in civil construction in Brazil. The national standard for thermal performance and the energy efficiency labeling program do not require the use of thermal insulation in the building envelope, even for the hottest and for the coldest regions of the country. Brazil has a temperate climate region that covers 7.2% of its territory and contains important and populous cities. This paper explores the benefits of the use of thermal i...

  10. Ventilation for Free

    NARCIS (Netherlands)

    Scholten, R.D.; Ter Haar, J.

    2014-01-01

    This "designers' manual" is made during the TIDO-course AR0533 Innovation & Sustainability. The goal of this manual is to give a clear and simple overview of some of the possibilities for using natural ventilation in buildings. These systems are described through their formulas to give an idea of

  11. Balancing energy conservation and occupant needs in ventilation rate standards for Big Box stores and other commercial buildings in California. Issues related to the ASHRAE 62.1 Indoor Air Quality Procedure

    Energy Technology Data Exchange (ETDEWEB)

    Mendell, Mark J. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Apte, Mike G. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2010-10-31

    This report considers the question of whether the California Energy Commission should incorporate the ASHRAE 62.1 ventilation standard into the Title 24 ventilation rate (VR) standards, thus allowing buildings to follow the Indoor Air Quality Procedure. This, in contrast to the current prescriptive standard, allows the option of using ventilation rate as one of several strategies, which might include source reduction and air cleaning, to meet specified targets of indoor air concentrations and occupant acceptability. The research findings reviewed in this report suggest that a revised approach to a ventilation standard for commercial buildings is necessary, because the current prescriptive ASHRAE 62.1 Ventilation Rate Procedure (VRP) apparently does not provide occupants with either sufficiently acceptable or sufficiently healthprotective air quality. One possible solution would be a dramatic increase in the minimum ventilation rates (VRs) prescribed by a VRP. This solution, however, is not feasible for at least three reasons: the current need to reduce energy use rather than increase it further, the problem of polluted outdoor air in many cities, and the apparent limited ability of increasing VRs to reduce all indoor airborne contaminants of concern (per Hodgson (2003)). Any feasible solution is thus likely to include methods of pollutant reduction other than increased outdoor air ventilation; e.g., source reduction or air cleaning. The alternative 62.1 Indoor Air Quality Procedure (IAQP) offers multiple possible benefits in this direction over the VRP, but seems too limited by insufficient specifications and inadequate available data to provide adequate protection for occupants. Ventilation system designers rarely choose to use it, finding it too arbitrary and requiring use of much non-engineering judgment and information that is not readily available. This report suggests strategies to revise the current ASHRAE IAQP to reduce its current limitations. These

  12. Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm

    Displacement ventilation is an interesting new type of air distribution principle which should be considered in connection with design of comfort ventilation in both smal1 and large spaces. Research activities on displacement ventilation are large all over the world and new knowledge of design...... methods appears continuously. This book gives an easy introduction to the basis of displacement ventilation and the chapters are written in the order which is used in a design procedure. The main text is extended by five appendices which show some of the new research activities taking place at Aalborg...

  13. Building

    OpenAIRE

    Seavy, Ryan

    2014-01-01

    Building for concrete is temporary. The building of wood and steel stands against the concrete to give form and then gives way, leaving a trace of its existence behind. Concrete is not a building material. One does not build with concrete. One builds for concrete. MARCH

  14. Summary of human responses to ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli A.; Fisk, William J.

    2004-06-01

    The effects of ventilation on indoor air quality and health is a complex issue. It is known that ventilation is necessary to remove indoor generated pollutants from indoor air or dilute their concentration to acceptable levels. But, as the limit values of all pollutants are not known, the exact determination of required ventilation rates based on pollutant concentrations and associated risks is seldom possible. The selection of ventilation rates has to be based also on epidemiological research (e.g. Seppanen et al., 1999), laboratory and field experiments (e.g. CEN 1996, Wargocki et al., 2002a) and experience (e.g. ECA 2003). Ventilation may also have harmful effects on indoor air quality and climate if not properly designed, installed, maintained and operated as summarized by Seppdnen (2003). Ventilation may bring indoors harmful substances that deteriorate the indoor environment. Ventilation also affects air and moisture flow through the building envelope and may lead to moisture problems that deteriorate the structures of the building. Ventilation changes the pressure differences over the structures of building and may cause or prevent the infiltration of pollutants from structures or adjacent spaces. Ventilation is also in many cases used to control the thermal environment or humidity in buildings. Ventilation can be implemented with various methods which may also affect health (e.g. Seppdnen and Fisk, 2002, Wargocki et al., 2002a). In non residential buildings and hot climates, ventilation is often integrated with air-conditioning which makes the operation of ventilation system more complex. As ventilation is used for many purposes its health effects are also various and complex. This paper summarizes the current knowledge on positive and negative effects of ventilation on health and other human responses. The focus of the paper is on office-type working environment and residential buildings. In the industrial premises the problems of air quality are usually

  15. Seasonal and diel variations of ammonia and methane emissions from a naturally ventilated dairy building and the associated factors influencing emissions.

    Science.gov (United States)

    Saha, C K; Ammon, C; Berg, W; Fiedler, M; Loebsin, C; Sanftleben, P; Brunsch, R; Amon, T

    2014-01-15

    Understanding seasonal and diel variations of ammonia (NH3) and methane (CH4) emissions from a naturally ventilated dairy (NVD) building may lead to develop successful control strategies for reducing emissions throughout the year. The main objective of this study was to quantify seasonal and diel variations of NH3 and CH4 emissions together with associated factors influencing emissions. Measurements were carried out with identical experimental set-up to cover three winter, spring and summer seasons, and two autumn seasons in the years 2010, 2011, and 2012. The data from 2010 and 2011 were used for developing emission prediction models and the data from 2012 were used for model validation. The results showed that NH3 emission varied seasonally following outside temperature whereas CH4 emission did not show clear seasonal trend. Diel variation of CH4 emission was less pronounced than NH3. The average NH3 and CH4 emissions between 6a.m. and 6p.m. were 66% and 33% higher than the average NH3 and CH4 emissions between 6p.m. and 6a.m., respectively for all seasons. The significant relationships (Pclimate factors, hours of the day and days of the year on CH4 emission might be directly related to activities of the cows. © 2013.

  16. Ventilation with heat recovery

    DEFF Research Database (Denmark)

    Tommerup, Henrik M.; Svendsen, Svend

    2005-01-01

    This paper presents the experiences from the use of ventilation with heat recovery in several experimental single-family houses developed and built within the last four years to meet the new Danish energy requirements of 2005. Included are descriptions of the ventilation system components...... and the main functional demands as well as measurements of the thermal efficiency, electricity consumptions and building air tightness. The paper addresses the aspects of minimizing the heat loss from the duct system and the heat recovery unit (when placed in an unheated attic space) in order to obtain...

  17. Application of Building Basement Ventilation Engineering, Smoke Engineering%浅谈建筑地下室中通风工程、防排烟工程的应用

    Institute of Scientific and Technical Information of China (English)

    程剑

    2015-01-01

    通过分析建筑地下室通风工程和防排烟工程的设计思路和存在的问题,提出了相应的优化设计和解决方法。%By analyzing the building basement ventilation and smoke control engineering project design ideas and problems, put forward the corresponding design and optimization solutions.

  18. Liquid Ventilation

    Directory of Open Access Journals (Sweden)

    Qutaiba A. Tawfic

    2011-01-01

    Full Text Available Mammals have lungs to breathe air and they have no gills to breath liquids. When the surface tension at the air-liquid interface of the lung increases, as in acute lung injury, scientists started to think about filling the lung with fluid instead of air to reduce the surface tension and facilitate ventilation. Liquid ventilation (LV is a technique of mechanical ventilation in which the lungs are insufflated with an oxygenated perfluorochemical liquid rather than an oxygen-containing gas mixture. The use of perfluorochemicals, rather than nitrogen, as the inert carrier of oxygen and carbon dioxide offers a number of theoretical advantages for the treatment of acute lung injury. In addition, there are non-respiratory applications with expanding potential including pulmonary drug delivery and radiographic imaging. The potential for multiple clinical applications for liquid-assisted ventilation will be clarified and optimized in future. Keywords: Liquid ventilation; perfluorochemicals; perfluorocarbon; respiratory distress; surfactant.

  19. Livestock Vaccine Innovation Fund: Strengthening of Research ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    This project creates the authorization for capacity building support to develop and manage the Livestock Vaccine Innovation Fund (LVIF). The fund aims to support the development of quality vaccines that are more affordable, available, and acceptable to small-scale farmers. It will also help ensure their use at scale.

  20. Ventilator graphics.

    Science.gov (United States)

    Prabhakaran, Priya; Sasser, William C; Kalra, Yuvrai; Rutledge, Chrystal; Tofil, Nancy M

    2016-12-01

    Providing optimal mechanical ventilation to critically-ill children remains a challenge. Patient-ventilator dyssynchrony results frequently with numerous deleterious consequences on patient outcome including increased requirement for sedation, prolonged duration of ventilation, and greater imposed work of breathing. Most currently used ventilators have real-time, continuously-displayed graphics of pressure, volume, and flow versus time (scalars) as well as pressure, and flow versus volume (loops). A clear understanding of these graphics provides a lot of information about the mechanics of the respiratory system and the patient ventilator interaction in a dynamic fashion. Using this information will facilitate tailoring the support provided and the manner in which it is provided to best suit the dynamic needs of the patient. This paper starts with a description of the scalars and loops followed by a discussion of the information that can be obtained from each of these graphics. A review will follow, on the common types of dyssynchronous interactions and how each of these can be detected on the ventilator graphics. The final section discusses how graphics can be used to optimize the ventilator support provided to patients.

  1. Wind Extraction for Natural Ventilation

    Science.gov (United States)

    Fagundes, Tadeu; Yaghoobian, Neda; Kumar, Rajan; Ordonez, Juan

    2017-11-01

    Due to the depletion of energy resources and the environmental impact of pollution and unsustainable energy resources, energy consumption has become one of the main concerns in our rapidly growing world. Natural ventilation, a traditional method to remove anthropogenic and solar heat gains, proved to be a cost-effective, alternative method to mechanical ventilation. However, while natural ventilation is simple in theory, its detailed design can be a challenge, particularly for wind-driven ventilation, which its performance highly involves the buildings' form, surrounding topography, turbulent flow characteristics, and climate. One of the main challenges with wind-driven natural ventilation schemes is due to the turbulent and unpredictable nature of the wind around the building that impose complex pressure loads on the structure. In practice, these challenges have resulted in founding the natural ventilation mainly on buoyancy (rather than the wind), as the primary force. This study is the initial step for investigating the physical principals of wind extraction over building walls and investigating strategies to reduce the dependence of the wind extraction on the incoming flow characteristics and the target building form.

  2. Design of Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    The effectiveness of natural ventilation, i.e. its ability to ensure indoor air quality and passive cooling in a building, depends greatly on the design process. Mechanical ventilation systems can be designed separately from the design of the building in which they are installed. They can also...... be installed in existing buildings after a few modifications. In contrast, ventilation systems using only natural forces such as wind and thermal buoyancy need to be designed together with the building, since the building itself and its components are the elements that can reduce or increase air movement...... as well as influence the air content (dust, pollution etc.). Architects and engineers need to acquire qualitative and quantitative information about the interactions between building characteristics and natural ventilation in order to design buildings and systems consistent with a passive low...

  3. Modelling of Natural and Hybrid Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per

    as well as influence the air content (dust, pollution etc.). Architects and engineers need to acquire qualitative and quantitative information about the interactions between building characteristics and natural ventilation in order to design buildings and systems consistent with a passive low......The effectiveness of natural ventilation, i.e. its ability to ensure indoor air quality and passive cooling in a building, depends greatly on the design process. Mechanical ventilation systems can be designed separately from the design of the building in which they are installed. They can also...... be installed in existing buildings after a few modifications. In contrast, ventilation systems using only natural forces such as wind and thermal buoyancy need to be designed together with the building, since the building itself and its components are the elements that can reduce or increase air movement...

  4. Experimental Analysis and Model Validation of an Opaque Ventilated Facade

    DEFF Research Database (Denmark)

    López, F. Peci; Jensen, Rasmus Lund; Heiselberg, Per

    2012-01-01

    Natural ventilation is a convenient way of reducing energy consumption in buildings. In this study an experimental module of an opaque ventilated façade (OVF) was built and tested for assessing its potential of supplying free ventilation and air preheating for the building. A numerical model was ...

  5. Experimental Study of Air Distribution and Ventilation Effectiveness in a Room with a Combination of Different Mechanical Ventilation and Heating/Cooling Systems

    DEFF Research Database (Denmark)

    Olesen, Bjarne W.; Simone, Angela; Krajcik, Michal

    2011-01-01

    Mixing and displacement ventilation are common systems in commercial buildings, while mixing ventilation is used in residential buildings. Displacement ventilation provides fresh air to the occupied zone in a more efficient way than mixing ventilation but it is important to know how well it works...

  6. Mechanical Ventilation

    Science.gov (United States)

    ... cared for in a hospital’s intensive care unit (ICU). People who need a ventilator for a longer time may be in a regular unit of a hospital, a rehabilitation facility, or cared for at home. Why are ...

  7. Low home ventilation rate in combination with moldy odor from the building structure increase the risk for allergic symptoms in children

    DEFF Research Database (Denmark)

    Hägerhed-Engman, L.; Sigsgaard, T.; Samuelson, I.

    2009-01-01

    ventilation rate in combination with moldy odor along the skirting board further increased the risk for three out of four studied outcomes, indicating that the ventilation rate is an effect modifier for indoor pollutants.This study showed that mold odor at the skirting board level is strongly associated...... for an investigation of possible moisture damage, measurements, and choice of actions. In homes with low ventilation in combination with mold odor along the skirting board, there was even a higher risk of health effects. This emphasizes the need for the appropriate remediation as this is an ever increasing problem...

  8. Indoor Air Quality: Is Increased Ventilation the Answer?

    Science.gov (United States)

    Hansen, Shirley

    1989-01-01

    Explains how indoor air quality is affected by pollutants in the air and also by temperature, humidity, and ventilation. Increased ventilation alone seldom solves the "sick building syndrome." Lists ways to improve indoor air quality and optimize energy efficiency. (MLF)

  9. Harnessing natural ventilation benefits.

    Science.gov (United States)

    O'Leary, John

    2013-04-01

    Making sure that a healthcare establishment has a good supply of clean fresh air is an important factor in keeping patients, staff, and visitors, free from the negative effects of CO2 and other contaminants. John O'Leary of Trend Controls, a major international supplier of building energy management solutions (BEMS), examines the growing use of natural ventilation, and the health, energy-saving, and financial benefits, that it offers.

  10. Moulds in floor dust - a particular problem in mechanically ventilated rooms? A study of adolescent schoolboys under the Danish moulds in buildings program

    DEFF Research Database (Denmark)

    Meyer, Harald W; Suadicani, Poul; Nielsen, Peter A

    2011-01-01

    form might be a result of the higher air flow keeping the dust in the breathing zone for a longer time, thereby increasing the exposure for the occupants of the classrooms. It is important in future indoor air research also to focus on the combination effects of risk factors, including the type......), the negative effect of high levels of mould in floor dust was more pronounced in rooms with mechanical ventilation system. With a variable combining high level of moulds in floor dust with type of ventilation in the classroom, a significantly increased risk was found for all symptoms in the mechanically...... ventilated classrooms with high mould concentrations. In multiple logistic regression models, significant odds ratios (OR) ranged from 3.9 [95% confidence interval (95% CI) 1.5-10.1] (nasal congestion) to 17.0 (95% CI 2.1-138) (dizziness). CONCLUSIONS: The combined effect of moulds in dust and ventilation...

  11. Livestock biodiversity and sustainability

    NARCIS (Netherlands)

    Hoffmann, I.

    2011-01-01

    Sustainable development equally includes environmental protection including biodiversity, economic growth and social equity, both within and between generations. The paper first reviews different aspects related to the sustainable use of livestock biodiversity and property regimes that influence

  12. Comparative performance assessment of a non-ventilated and ventilated BIPV rooftop configurations in the Netherlands

    NARCIS (Netherlands)

    Ritzen, M.J.; Vroon, Z.A.E.P.; Rovers, R.; Geurts, C.P.W.

    2017-01-01

    Backside ventilation is one of the most common passive cooling methods of PV modules in the built environment, but might be under constraint when integrating PV in the building envelope. To investigate the short and long term effect of backside ventilation on Building Integrated PV (BIPV)

  13. ASHRAE and residential ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.

    2003-10-01

    In the last quarter of a century, the western world has become increasingly aware of environmental threats to health and safety. During this period, people psychologically retreated away from outdoors hazards such as pesticides, smog, lead, oil spills, and dioxin to the seeming security of their homes. However, the indoor environment may not be healthier than the outdoor environment, as has become more apparent over the past few years with issues such as mold, formaldehyde, and sick-building syndrome. While the built human environment has changed substantially over the past 10,000 years, human biology has not; poor indoor air quality creates health risks and can be uncomfortable. The human race has found, over time, that it is essential to manage the indoor environments of their homes. ASHRAE has long been in the business of ventilation, but most of the focus of that effort has been in the area of commercial and institutional buildings. Residential ventilation was traditionally not a major concern because it was felt that, between operable windows and envelope leakage, people were getting enough outside air in their homes. In the quarter of a century since the first oil shock, houses have gotten much more energy efficient. At the same time, the kinds of materials and functions in houses changed in character in response to people's needs. People became more environmentally conscious and aware not only about the resources they were consuming but about the environment in which they lived. All of these factors contributed to an increasing level of public concern about residential indoor air quality and ventilation. Where once there was an easy feeling about the residential indoor environment, there is now a desire to define levels of acceptability and performance. Many institutions--both public and private--have interests in Indoor Air Quality (IAQ), but ASHRAE, as the professional society that has had ventilation as part of its mission for over 100 years, is the

  14. Short-term airing by natural ventilation

    DEFF Research Database (Denmark)

    Perino, Marco; Heiselberg, Per

    2009-01-01

    traditional mechanical ventilation components with natural ventilation devices, such as motorized windows and louvers. Among the various ventilation strategies that are currently available, buoyancy driven single-sided natural ventilation has proved to be very effective and can provide high air change rates...... that was aimed at developing and validating numerical models for the analysis of buoyancy driven single-sided natural ventilation systems. Once validated, these models can be used to optimize control strategies in order to achieve satisfactory indoor comfort conditions and IAQ.......The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. This kind of system frequently integrates...

  15. Construction legislation and energy efficiency. A discussion on the covered open spaces for ventilation adopted by the Rio de Janeiro city building code, Brazil; Legislacao edilicia e eficiencia energetica. Uma discussao sobre os vaos de ventilacao adotados pelo codigo de obras do Rio de Janeiro

    Energy Technology Data Exchange (ETDEWEB)

    Pimenta, Gustavo Carvalho; Barroso-Krause, Claudia [Universidade Federal, Rio de Janeiro, RJ (Brazil). Faculdade de Arquitetura e Urbanismo. Programa de Pos-graduacao em Arquitetura]. E-mails: gparj@terra.com.br; bkrause@ufrj.br

    2002-07-01

    This paper analyses, under the energetic efficiency viewpoint, the critical points of the Rio de Janeiro city construction legislation, by the time that decrees the directives for covered open spaces for ventilation in multi-familiar buildings. The paper also demonstrates where and how the building code influences the architectonic project to induce energy consumption not contributing for an efficient architecture.

  16. A venturi-shaped roof for wind-induced natural ventilation of buildings : Wind tunnel and CFD evaluation of different design configurations

    NARCIS (Netherlands)

    Van Hooff, T.; Blocken, B.; Aanen, L.; Bronsema, B.

    2011-01-01

    Wind tunnel experiments and Computational Fluid Dynamics (CFD) are used to analyse the flow conditions in a venturi-shaped roof, with focus on the underpressure in the narrowest roof section (contraction). This underpressure can be used to partly or completely drive the natural ventilation of the

  17. Direct and indirect impacts of crop-livestock organization on mixed crop-livestock systems sustainability: a model-based study.

    Science.gov (United States)

    Sneessens, I; Veysset, P; Benoit, M; Lamadon, A; Brunschwig, G

    2016-11-01

    Crop-livestock production is claimed more sustainable than specialized production systems. However, the presence of controversial studies suggests that there must be conditions of mixing crop and livestock productions to allow for higher sustainable performances. Whereas previous studies focused on the impact of crop-livestock interactions on performances, we posit here that crop-livestock organization is a key determinant of farming system sustainability. Crop-livestock organization refers to the percentage of the agricultural area that is dedicated to each production. Our objective is to investigate if crop-livestock organization has both a direct and an indirect impact on mixed crop-livestock (MC-L) sustainability. In that objective, we build a whole-farm model parametrized on representative French sheep and crop farming systems in plain areas (Vienne, France). This model permits simulating contrasted MC-L systems and their subsequent sustainability through the following indicators of performance: farm income, production, N balance, greenhouse gas (GHG) emissions (/kg product) and MJ consumption (/kg product). Two MC-L systems were simulated with contrasted crop-livestock organizations (MC20-L80: 20% of crops; MC80-L20: 80% of crops). A first scenario - constraining no crop-livestock interactions in both MC-L systems - permits highlighting that crop-livestock organization has a significant direct impact on performances that implies trade-offs between objectives of sustainability. Indeed, the MC80-L20 system is showing higher performances for farm income (+44%), livestock production (+18%) and crop GHG emissions (-14%) whereas the MC20-L80 system has a better N balance (-53%) and a lower livestock MJ consumption (-9%). A second scenario - allowing for crop-livestock interactions in both MC20-L80 and MC80-L20 systems - stated that crop-livestock organization has a significant indirect impact on performances. Indeed, even if crop-livestock interactions permit

  18. Brucellosis vaccines for livestock.

    Science.gov (United States)

    Goodwin, Zakia I; Pascual, David W

    2016-11-15

    Brucellosis is a livestock disease responsible for fetal loss due to abortions. Worldwide, this disease has profound economic and social impact by reducing the ability of livestock producers to provide an adequate supply of disease-free meat and dairy products. In addition to its presence in domesticated animals, brucellosis is harbored in a number of wildlife species creating new disease reservoirs, which adds to the difficulty of eradicating this disease. Broad and consistent use of the available vaccines would contribute in reducing the incidence of brucellosis. Unfortunately, this practice is not common. In addition, the current brucellosis vaccines cannot provide sterilizing immunity, and in certain circumstances, vaccinated livestock are not protected against co-mingling Brucella-infected wildlife. Given that these vaccines are inadequate for conferring complete protection for some vaccinated livestock, alternatives are being sought, and these include genetic modifications of current vaccines or their reformulations. Alternatively, many groups have sought to develop new vaccines. Subunit vaccines, delivered as a combination of soluble vaccine plus adjuvant or the heterologous expression of Brucella epitopes by different vaccine vectors are currently being tested. New live attenuated Brucella vaccines are also being developed and tested in their natural hosts. Yet, what is rarely considered is the route of vaccination which could improve vaccine efficacy. Since Brucella infections are mostly transmitted mucosally, mucosal delivery of a vaccine has the potential of eliciting a more robust protective immune response for improved efficacy. Hence, this review will examine these questions and provide the status of new vaccines for livestock brucellosis. Copyright © 2016 Elsevier B.V. All rights reserved.

  19. Measures of Energy Economy in Livestock Housing

    Energy Technology Data Exchange (ETDEWEB)

    Kreslins, Andris; Ramata, Anna [Riga Technical University - Institute of Heat, Gas and Water Technology, Riga (Lithuania)

    2009-07-01

    For reduce production costs at agriculture, and wherewith costs for end product largely depend on consume of energy, how effective and useful it is used. Effective utilization of energy, sustainable agriculture and welfare of animals are interrelated activities. At 2001 The Council of the European Union accepted Directive 2001/88/EC laying down minimum welfare standards adaptable for the intensively kept pigs. These directives provide requirements concerning breeding of pigs and their welfare. The Cabinet of ministers of Latvia adapted a law Nr 5. 'General Requirements of Welfare for Agriculture Animals', which are legislate in accordance with law of Animal Protection. Under the rules, in livestock housing the owner must provide optimal air exchange, ventilation, temperature, relative humidity of air, level of concentration of gases, dusts and odours, which are harmless and agree for physiology requirements of animals. One of indices of animal welfare and factors of influence to productivity is quality of air parameters. To provide air parameters in livestock housing of pigs workings of ventilating system was analyzed. Usually traditional ventilating systems have high energy demand. We research, how to decrease consumption using heat - moisture balance and regenerative heat exchange apparatus for heat recovery from exhaust air. For study we employ outdoor air temperature and moisture climatology data per each month, about fluctuations of sun radiation and find more effective ventilating system, whose will have to provide an optimal heat and mass transfer. Meteorology parameter of air - temperature, moisture content, relative humidity, velocity of air, and temperature of surfaces - determine the microclimate of livestock housing. It is one of main animal's productivity and farm cost-efficiency influence factor. There is proven that optimal microclimate in livestock housing provide output up to 30 %. Animal nature can keep even optimal temperature of

  20. Displacement Ventilation in Hospital Environments

    DEFF Research Database (Denmark)

    Li, Yuguo; Nielsen, Peter V.; Sandberg, Mats

    2011-01-01

    Hospital differ from conventional buildings in terms of ventilation needs. Exhaled infectious droplets or droplet nuclei of an infected patient need to be removed in general wards, waiting areas and isolation rooms to minimize transmission to health-care workers, other patients and visitors...

  1. International Ventilation Cooling Application Database

    DEFF Research Database (Denmark)

    Holzer, Peter; Psomas, Theofanis Ch.; OSullivan, Paul

    2016-01-01

    The currently running International Energy Agency, Energy and Conservation in Buildings, Annex 62 Ventilative Cooling (VC) project, is coordinating research towards extended use of VC. Within this Annex 62 the joint research activity of International VC Application Database has been carried out, ...

  2. Estimation of Airflow in livestock Buildings

    DEFF Research Database (Denmark)

    Larsen, Rasmus

    1995-01-01

    -illuminated plane may be visualized. Based of sequences of images recorded of this plane local measurements of the velocity field are obtained by analysis of the local energy distribution, which is sampled using a set of 3-D spatio-temporal Gabor filters. We will show how physically inspired a priori distribution...... of the flow field may be used to integrate the local observations to a smooth field....

  3. The Effects of Ventilation in Homes on Health

    DEFF Research Database (Denmark)

    Wargocki, Pawel

    2013-01-01

    and to reduce emissions. Often, especially in existing buildings, this strategy is difficult to implement, in which case exposures are controlled by providing sufficient, presumably clean, outdoor ventilation air to dilute and remove the contaminants. The present paper attempts to find out how much ventilation...... in existing homes. No data were found indicating that buildings having dedicated natural ventilation systems perform less well than the dwellings in which mechanical ventilation systems are installed. Newly installed mechanical ventilation systems were observed to improve health conditions. In homes...... Guidelines for Indoor Air Quality and improving ventilation measurements). Exposures should also be controlled using different ventilation methods for comparison. Future studies should also advance the understanding of how ventilation systems should be operated to achieve optimal performance. These data...

  4. Functionality of Ventilated Facades: Protection of Insulation

    Directory of Open Access Journals (Sweden)

    Petrichenko Mikhail

    2016-01-01

    Full Text Available This article discusses about methods of construction of the ventilated facades. The ventilated facade is not only the element of facing, it is the supporting structure. Their main objective - creation of air ventilating space between a facade and an external wall of the building. Moving of air in this gap protects a heater from destruction, interfering with a moisture congestion. In addition, the ventilated facade protect the building from aggressive influence of external environment, have a sound and thermal insulation properties. There are several problems of systems of the ventilated facades connected with an application of a heater. For more effective using it is necessary to minimize contact of a heater with environment.

  5. Development of a Residential Integrated Ventilation Controller

    Energy Technology Data Exchange (ETDEWEB)

    Staff Scientist; Walker, Iain; Sherman, Max; Dickerhoff, Darryl

    2011-12-01

    The goal of this study was to develop a Residential Integrated Ventilation Controller (RIVEC) to reduce the energy impact of required mechanical ventilation by 20percent, maintain or improve indoor air quality and provide demand response benefits. This represents potential energy savings of about 140 GWh of electricity and 83 million therms of natural gas as well as proportional peak savings in California. The RIVEC controller is intended to meet the 2008 Title 24 requirements for residential ventilation as well as taking into account the issues of outdoor conditions, other ventilation devices (including economizers), peak demand concerns and occupant preferences. The controller is designed to manage all the residential ventilation systems that are currently available. A key innovation in this controller is the ability to implement the concept of efficacy and intermittent ventilation which allows time shifting of ventilation. Using this approach ventilation can be shifted away from times of high cost or high outdoor pollution towards times when it is cheaper and more effective. Simulations, based on the ones used to develop the new residential ventilation requirements for the California Buildings Energy code, were used to further define the specific criteria and strategies needed for the controller. These simulations provide estimates of the energy, peak power and contaminant improvement possible for different California climates for the various ventilation systems. Results from a field test of the prototype controller corroborate the predicted performance.

  6. Housing and natural ventilation. Indoor climate, energy, reliability; Bolig og naturlig ventilation: indeklima energi driftssikkerhed

    Energy Technology Data Exchange (ETDEWEB)

    Marsh, R.; Lauring, M. (eds.)

    2003-07-01

    The aim of this book is to show how natural ventilation can be used successfully in housing. Housing ventilation aims at balancing complex and often diametrically opposed demands. This book examines the complexity with different quantitative and qualitative approaches. In the first chapter, History, the Danish housing ventilation from 1850-2002 is examined. The requirements for natural ventilation have developed historically, based upon a spatial organisation with fresh air supply to the less polluted rooms and stack effect removal from the more polluted rooms. A series of important factors relating to a healthy indoor climate, energy savings and demands for functional stability have affected this development. In the second chapter, Models, a series of architectural models for natural ventilated large building types are analysed. There has for many years been much R and D activity aimed at using natural ventilation in large buildings. Much of the knowledge about the requirements for natural ventilation (spatial organisation, fresh air supply and stack effect removal) can therefore be used in the development of naturally ventilated housing. The third chapter, Principles, develops a set of principles for naturally ventilated housing by examining the requirements relating to spatial organisation, fresh air supply, and stack effect removal. By optimizing the architectural and technical design of a typical terraced house, the three aims for the successful use of natural ventilation in housing can be achieved; a very low energy consumption and environmental impact, a healthy indoor climate and a functionally stable ventilation system. The fourth chapter, Houses, presents architectural designs for a series of naturally ventilated terraced houses. The designs focus on the use of spatial organisation, fresh air supply and stack removal to optimize the natural ventilation. Architecture and technology are integrated in the design to achieve low energy consumption, a healthy

  7. Displacement Ventilation

    DEFF Research Database (Denmark)

    Bjørn, Erik; Mattsson, Magnus; Sandberg, Mats

    Full-scale experiments were made in a displacement ventilated room with two breathing thermal manikins to study the effect of movements and breathing on the vertical contaminant distribution, and on the personal exposure of occupants. Concentrations were measured with tracer gas equipment...... in the room and in the inhalation of both manikins. Tracer gas was added in the heat plume above a sitting manikin, or in the exhalation through either the nose or the mouth. The other manikin moved back and forth at different speeds on a low trolley. The mentioned experimental conditions have a significant...

  8. Kitchen ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Kelso, R.M. [Univ. of Tennessee, Knoxville, TN (United States). College of Architecture; Rousseau, C. [Newcomb and Boyd Consulting Engineers, Atlanta, GA (United States)

    1995-09-01

    Kitchen ventilation is a subject that has not received the attention that has been given to more glamorous HVAC and R topics. Consequently, its theoretical and technical development has not advanced like these topics. However, a group has been working within the ASHRAE Technical Committee (TC) and Task Group (TG) framework to correct this situation. The group is TG5.KV and it achieved TG status last year after starting as an informal group and then a sub-committee of TC9.8. One of its efforts has been to write a Handbook chapter, which will appear in the 1995 ASHRAE Handbook -- Applications. This article is a survey of that chapter.

  9. Demand controlled ventilation for multi-family dwellings

    DEFF Research Database (Denmark)

    Mortensen, Dorthe Kragsig

    for ventilation in residential buildings that depend on occupancy, pollutant emission, etc., and results in periods with poor air quality and/or unnecessary energy consumption. If the ventilation rate is varied according to the demand, the indoor climate can be improved and the energy consumption for ventilation...... specify desired levels of indoor air quality through ventilation rate requirements. The Danish Building Code requires a constant air flow rate equivalent to at least 0.5 air changes per hour in residential buildings. A constant air flow requirement is inconsistent with the time varying needs...

  10. Investigation of Ventilation Strategies for the Day-Care Institutions

    DEFF Research Database (Denmark)

    Larsen, Olena Kalyanova; Afshari, Alireza; Heiselberg, Per

    2011-01-01

    Two existing nursery buildings, a mechanically and a naturally ventilated one, were chosen for investigations of energy saving potential and IAQ, using the different from present ventilation strategies and their control principles. These investigations are carried out applying a dynamic building ...

  11. Residential ventilation standards scoping study

    Energy Technology Data Exchange (ETDEWEB)

    McKone, Thomas E.; Sherman, Max H.

    2003-10-01

    The goals of this scoping study are to identify research needed to develop improved ventilation standards for California's Title 24 Building Energy Efficiency Standards. The 2008 Title 24 Standards are the primary target for the outcome of this research, but this scoping study is not limited to that timeframe. We prepared this scoping study to provide the California Energy Commission with broad and flexible options for developing a research plan to advance the standards. This document presents the findings of a scoping study commissioned by the Public Interest Energy Research (PIER) program of the California Energy Commission to determine what research is necessary to develop new residential ventilation requirements for California. This study is one of three companion efforts needed to complete the job of determining the ventilation needs of California residences, determining the bases for setting residential ventilation requirements, and determining appropriate ventilation technologies to meet these needs and requirements in an energy efficient manner. Rather than providing research results, this scoping study identifies important research questions along with the level of effort necessary to address these questions and the costs, risks, and benefits of pursuing alternative research questions. In approaching these questions and corresponding levels of effort, feasibility and timing were important considerations. The Commission has specified Summer 2005 as the latest date for completing this research in time to update the 2008 version of California's Energy Code (Title 24).

  12. Measurements of radon-daughter concentrations in and around dwellings in the northern part of the Netherlands; a search for the influences of building materials, construction and ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Wolfs, F.; Hofstede, H.; De Meijer, R.J.; Put, L.W.

    1984-08-01

    The concentration of radon daughters has been determined in and around 80 dwellings located in the northern part of the Netherlands by using a one-filter method. Median values of 2.0 and 0.4 mWL were measured for the indoor and outdoor concentrations, respectively. On the average, dwellings with double-pain windows and/or concrete floors were to have significantly higher radon concentrations than those with single-pane windows and/or wooden floors. For the living room of a particular dwelling 18 measurements were carrried out. The data for this dwelling indicate a linear relation between the concentration indoors and outdoors with a slope of 3.8 +/- 2.0. This unexpected behaviour is thought to be related to ventilation via the crawl space.

  13. Achieving Natural and Hybrid Ventilation in Practice

    DEFF Research Database (Denmark)

    Liddament, Martin; Axley, James; Heiselberg, Per

    2006-01-01

    Case studies provide essential evidence about the performance of buildings. They also illustrate the methods by which a technology can be implemented as well as highlighting problems. Various case study buildings (both new and retrofit) that incorporate mixed mode, natural ventilation and low...... energy cooling are reviewed in this paper. An outline of the tasks that ventilation is required to perform is also presented. The results show that many buildings perform well and can provide good thermal comfort and air quality for much of the occupied period. Various solutions have been introduced...

  14. Particulate matter emission from livestock houses: measurement methods, emission levels and abatement systems

    NARCIS (Netherlands)

    Winkel, Albert

    2016-01-01

    Animal houses are extremely dusty environments. Airborne particulate matter (PM) poses a health threat not only to the farmer and the animals, but, as a result of emissions from ventilation systems, also to residents living in livestock farming areas. In relation to this problem, the objectives of

  15. Short Term Airing by Natural Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Perino, M.

    2010-01-01

    that are currently available, buoyancy driven, single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and Indoor Air Quality (IAQ) control. However, to promote a wider distribution of these systems an improvement in the knowledge of their working......The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. Among the available ventilation strategies...... principles is necessary. The present study analyses and presents the results of an experimental evaluation of airing performance in terms of ventilation characteristics, IAQ and thermal comfort. It includes investigations of the consequences of opening time, opening frequency, opening area and expected...

  16. Potential of Natural Ventilation in Shopping Centres

    DEFF Research Database (Denmark)

    Diederichsen, Alice; Friis, Kristina; Brohus, Henrik

    2008-01-01

    The indoor environmental quality (IEQ) is a fundamental requirement for a well performing shopping centre. This paper contains a pilot study of the potential of using hybrid ventilation (a combination of automatically controlled natural and mechanical ventilation - respectively NV and MV) in shop......The indoor environmental quality (IEQ) is a fundamental requirement for a well performing shopping centre. This paper contains a pilot study of the potential of using hybrid ventilation (a combination of automatically controlled natural and mechanical ventilation - respectively NV and MV......) in shopping centres with focus on both the achieved IEQ and energy consumptions for air movement. By thermal building simulations it is found that there exists an interesting potential for hybrid ventilation of shopping centres, which can lead to great savings in the electrical energy consumptions...

  17. Variable mechanical ventilation

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini Jr., Luiz Alberto; Friedman, Gilberto

    2017-01-01

    Objective To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Conclusion Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation. PMID:28444076

  18. VENTILATION NEEDS DURING CONSTRUCTION

    Energy Technology Data Exchange (ETDEWEB)

    C.R. Gorrell

    1998-07-23

    The purpose of this analysis is to determine ventilation needs during construction and development of the subsurface repository and develop systems to satisfy those needs. For this analysis, construction is defined as pre-emplacement excavation and development is excavation that takes place simultaneously with emplacement. The three options presented in the ''Overall Development and Emplacement Ventilation Systems'' analysis (Reference 5.5) for development ventilation will be applied to construction ventilation in this analysis as well as adding new and updated ventilation factors to each option for both construction and development. The objective of this analysis is to develop a preferred ventilation system to support License Application Design. The scope of this analysis includes: (1) Description of ventilation conditions; (2) Ventilation factors (fire hazards, dust control, construction logistics, and monitoring and control systems); (3) Local ventilation alternatives; (4) Global ventilation options; and (5) Evaluation of options.

  19. Variable mechanical ventilation.

    Science.gov (United States)

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini, Luiz Alberto; Friedman, Gilberto

    2017-01-01

    To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE®, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". A total of 36 studies were selected. Of these, 24 were original studies, including 21 experimental studies and three clinical studies. Several experimental studies reported the beneficial effects of distinct variable ventilation strategies on lung function using different models of lung injury and healthy lungs. Variable ventilation seems to be a viable strategy for improving gas exchange and respiratory mechanics and preventing lung injury associated with mechanical ventilation. However, further clinical studies are necessary to assess the potential of variable ventilation strategies for the clinical improvement of patients undergoing mechanical ventilation.

  20. Variable mechanical ventilation

    OpenAIRE

    Fontela, Paula Caitano; Prestes, Renata Bernardy; Forgiarini Jr.,Luiz Alberto; Friedman, Gilberto

    2017-01-01

    Objective To review the literature on the use of variable mechanical ventilation and the main outcomes of this technique. Methods Search, selection, and analysis of all original articles on variable ventilation, without restriction on the period of publication and language, available in the electronic databases LILACS, MEDLINE?, and PubMed, by searching the terms "variable ventilation" OR "noisy ventilation" OR "biologically variable ventilation". Results A total of 36 studies were selected. ...

  1. African Journal of Livestock Extension

    African Journals Online (AJOL)

    African Journal of Livestock Extension aims to bring to the fore the role and significance of livestock in maintaining rural, peri-urban and urban households, vis-à-vis its impact on poverty alleviation, household nutritional status, economic coping strategy and provision of employment. The focus of the journal relates to all ...

  2. Women's Participation in Livestock Markets

    International Development Research Centre (IDRC) Digital Library (Canada)

    Women's participation in marketing of live animals. (cattle, sheep and goats) tends to be much lower than their participation in the milk market. Generally, they have far more rights over livestock products. Women's Participation in Livestock Markets. Elizabeth Waithanji, Jemimah Njuki and Nabintu Bagalwa. With training and ...

  3. Impacts of European livestock production

    NARCIS (Netherlands)

    Leip, Adrian; Billen, Gilles; Garnier, Josette; Grizzetti, Bruna; Lassaletta, Luis; Reis, Stefan; Simpson, David; Sutton, M.A.; Vries, De Wim; Weiss, Franz; Westhoek, Henk

    2015-01-01

    Livestock production systems currently occupy around 28% of the land surface of the European Union (equivalent to 65% of the agricultural land). In conjunction with other human activities, livestock production systems affect water, air and soil quality, global climate and biodiversity, altering

  4. Modelling Livestock Component in FSSIM

    NARCIS (Netherlands)

    Thorne, P.J.; Hengsdijk, H.; Janssen, S.J.C.; Louhichi, K.; Keulen, van H.; Thornton, P.K.

    2009-01-01

    This document summarises the development of a ruminant livestock component for the Farm System Simulator (FSSIM). This includes treatments of energy and protein transactions in ruminant livestock that have been used as a basis for the biophysical simulations that will generate the input production

  5. Airborne fungi in non-problem buildings in a southern-hemisphere mediterranean climate: preliminary study of natural and mechanical ventilation

    Energy Technology Data Exchange (ETDEWEB)

    Kemp, P.C.; Murry, F. [School of Environmental Science, Murdoch University, Murdoch (Australia); Neumeister-Kemp, H.G. [Freie Universitaet Berlin, Berlin (Germany); Lysek, G. [Fachbereich Botanik, Freie Universitaet Berlin, Berlin (Germany)

    2002-07-01

    There is a growing body of evidence on fungal contamination in moisture-damaged and complaint buildings worldwide, but little is known about the occurrence and distribution of fungi in healthy non-complaint buildings in a southern-hemisphere climate. The study tested the hypothesis that fungi in healthy buildings are low in numbers and very similar to the numbers and mixtures of species in both the outdoor air and the outdoor air in other parts of the world. Fungi were collected using a 6-stage Andersen sampler, and various indoor air quality (IAQ) indicators and a sick-building syndrome (SBS) questionnaire were used in parallel. The results showed that all IAQ parameters were within USA and Canadian guidelines in all the buildings. There was also a low incidence of SBS complaints and symptoms. The total colony-forming unit (CFU) counts were also low, and the range of fungal species was low compared to buildings in other parts of the world. However, the mixture of fungal genera in the indoor air was different from the outdoor air. There were also substantial differences between indoor locations. At some locations fungi including 'Aspergillus niger', 'Penicillium' spp. and 'Alternaria alternata' were much higher indoors than outdoors or, as the pathogen 'Paecilomyces lilacinus', were absent in the outdoor air indicating indoor sources. Differentiation of fungal species was required to identify indoor fungal sources as the outdoor air was not the major source of indoor fungi. The study also demonstrated that evaluating the potential exposure to airborne fungi in indoor air requires differentiation to the species level as simple CFU counts could not differentiate between benign and potentially harmful fungi. (author)

  6. Calculation of Industrial Enterprise Ventilation System by Network Integral Method

    Directory of Open Access Journals (Sweden)

    Mihienkova Evgeniya I.

    2016-01-01

    Full Text Available This paper describe a ventilation system calculation of the technology building industrial enterprise. On the basis of the calculation model for the enterprise offered technical decision of ventilation systems, subject to a compliance exchange multiplicity, purification efficiency, decontamination from the work area; provided the required volume of gas extraction from process equipment according to the sanitary standards and environmental requirements. Produced selection of ventilation equipment parameters, solved the problem of the air exchange balancing between ventilation systems to prevent the emergence of parasitic flows between the rooms building. SigmaNet software package was used for the implement the calculation.

  7. Biotechnology developments in the livestock sector in developing countries.

    Science.gov (United States)

    Onteru, Suneel; Ampaire, Agatha; Rothschild, Max

    2010-01-01

    Global meat and milk consumption is exponentially increasing due to population growth, urbanization and changes in lifestyle in the developing world. This is an excellent opportunity for developing countries to improve the livestock sector by using technological advances. Biotechnology is one of the avenues for improved production in the "Livestock revolution". Biotechnology developments applied to livestock health, nutrition, breeding and reproduction are improving with a reasonable pace in developing countries. Simple bio-techniques such as artificial insemination have been well implemented in many parts of the developing world. However, advanced technologies including transgenic plant vaccines, marker assisted selection, solid state fermentation for the production of fibrolytic enzymes, transgenic fodders, embryo transfer and animal cloning are confined largely to research organizations. Some developing countries such as Taiwan, China and Brazil have considered the commercialization of biotechnology in the livestock sector. Organized livestock production systems, proper record management, capacity building, objective oriented research to improve farmer's income, collaborations with the developed world, knowledge of the sociology of an area and research on new methods to educate farmers and policy makers need to be improved for the creation and implementation of biotechnology advances in the livestock sector in the developing world.

  8. Solar collector Suntherm. Laboratory test. Full scale test for preheating of ventilation air in a building for piglets. Solfaangare Suntherm. Laboratorieprovning. Fullskaletest foer foervaermning av stalluft

    Energy Technology Data Exchange (ETDEWEB)

    Gustafsson, G.; Hedstroem, R.

    1988-06-30

    A test of the solar collector 'SUNTHERM' has been performed. The solar collector has a suspended, permeable absorber covered with a corrugated plastic sheet. In the laboratory the momentary efficiency was measured when solar radiation exceeded 630 W/m/sup 2/. At specific air flows greater than 0.01 m/sup 3//(m/sup 2/ s), the upper absorber surface of the solar collector had the same temperature as the exhaust air. The air temperature in the exhaust air duct of the solar collector can therefore be controlled which means that conduction losses through the covering can be minimized. The effective heat transfer coefficient of the device was 17.3 W/(m/sup 2/k). A field study was made of a SUNTHERM heating device installed at a farm in southern Sweden. The area of the solar collector was 40 m/sup 2/. It was placed on the south gablewall of a pig house. It was used to preheat ventilation air. The energy supply from the collector during the test period, was about 1 300 kWh. The average efficiency of the device for the whole period was about 21 %. Some defects in the device were observed during the test period including some design errors. By correcting these errors it should be possible to increase the efficiency of the system to 25 to 30 %.

  9. Development of energy-efficient comfortable ventilation systems with air quality guided volume flow control and continuous monitoring of the window opening status. Part 1. Use of the LuQaS triple sensor for air quality guided volume flow control of mechanical ventilation systems in domestic buildings. Research project; Entwicklung energieeffizienter Komfortlueftungsanlagen mit luftqualitaetsgefuehrter Volumenstromregelung und kontinuierlicher Erfassung des Fensteroeffnungszustandes. Teilbericht 1. Einsatz des LuQaS-Triple-Sensors zur luftqualitaetsgefuehrten Volumenstromregelung von mechanischen Lueftungsanlagen in Wohngebaeuden. Forschungsprojekt

    Energy Technology Data Exchange (ETDEWEB)

    Grossklos, Marc; Ebel, Witta; Knissel, Jens

    2011-05-15

    The report presents the preparatory work on the research project of the above title. The first chapter presents a status report on air quality monitoring inside rooms and evaluates the projects so far in which the LuQaS air quality sensor was used. The second chapter is a documentation of preliminary measurements using the LuQaS sensor in two passive residential buildings and several individual measurements for sensor calibration. It was found that in apartments with mechanical ventilation, the sensor reflects the user activities; further, the measured values indicate signal changes also in the off-air of the building, so that control via central sensors in the ventilation and off-air systems appears feasible. The third chapter discusses control strategies for air quality control. Apart from a discussion of control unit types, operating regimes, methods to determine rated values, and additional control functions, the effects of threshold value control with different threshold limit values and volume flow changes on the air quality of a model building was simulated. The results prove the expectation that the air quality inside a building will be influenced positively by air quality control. Theoretical investigations of the DrD method will be presented in another part-report of the project.

  10. Ventilator associated pneumonia or ventilator induced pneumonia.

    Science.gov (United States)

    Khan, Zahid Hussain; Ceriana, Piero; Donner, Claudio F

    2017-01-01

    Ventilator associated pneumonia currently in vogue seems to have some pitfalls as far as the nomenclature is concerned and thus it imparts an erroneous impression to the reader. As the driving force is in fact the ventilator, the phraseology should preferably be changed to ventilator induced pneumonia to convey the in depth meaning of the term thus evading the terminology currently in practice. A new and emerging paradigm dealing with all side effects of mechanical ventilation can be helpful to solve this etymological conflict.

  11. Ventilation effectiveness : health benefits of heat recovery ventilators

    Energy Technology Data Exchange (ETDEWEB)

    Anon.

    2010-08-15

    Studies have shown that the installation of a heat recovery ventilator (HRV) in homes in northern Canada could improve indoor air quality and the respiratory health of inhabitants. Low ventilation rates are common in many homes in the North because the climate is severe, homes are smaller and lack basements, and occupancies are higher, leading to unhealthy indoor air quality. Northern communities also have a high rate of respiratory infections. HRVs recover much of the energy used to ventilate, which is desirable in cold regions with high heating costs. For the study, the test sample was divided into two types of houses, notably houses with active HRVs and those with control HRVs that were installed and operated but that did not function. The study results showed that HRVs provided increased ventilation. Complaints by residents about HRV noise, discomfort, or low humidity were common but equally spread between those with active and placebo HRVs. The study showed that the system design needs to be improved to better suit the needs of Inuit families. The nature of northern housing presents installation and maintenance challenges. It is hard to retrofit HRV ducting inside small, existing houses, and building supplies arrive infrequently, so detailed planning and careful take-offs of all supplies and materials must be done well in advance of construction. In addition, contractors are hard to locate and have variable expertise, and there is little technical follow-up. Robust technical support by local contractors and housing authorities is therefore important. 2 refs.

  12. Demand-controlled mechanical ventilation. Behovsstyret mekanisk ventilation; Fugt som reguleringsparameter - et pilotprojekt

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    This report presents the results from the registration throughout a month of relative humidity, temperature and outdoor air exchanger as well as the concentration of carbon dioxide in each room of an inhabited single family house, in which all rooms are ventilated by a mechanical balanced ventilation system with variable air volume. The ventilation outdoor air rate is controlled by the relative humidity, which is kept on a value adequate to reduce the living conditions for house dust mites and prevent condensation on the indoor surfaces of the building. Due to the demand control ventilation of each individual room a higher efficiency for reducing water vapors in the dwelling as a whole is likely to be achieved. The results show that it is possible with this kind of ventilation system and in the context of Danish outdoor climate to maintain humidity conditions that is anticipated to reduce the number of house dust mites in all rooms of a dwelling during more than five months of the year. In all the months the mean daily mechanical ventilation rate is estimated to be 39% below the level recommended in the Danish Building Code. At the same time indoor condensation was avoided on poorly insulated surfaces of the building. The concentration of carbon dioxide was below the level recommended in international ventilation standards. (au) (13 refs.)

  13. Low resource ventilation unit; Ressourcebesparende ventilationsenhed

    Energy Technology Data Exchange (ETDEWEB)

    Drivsholm, C.

    2012-03-15

    In the project a resource-saving ventilation device was developed which is based on the use of a regenerator and a reversible air flow. The regenerator is placed in the building envelope, and the concept works in the way that the heat in the air during ventilation is stored in the regenerator and brought back into the building by a reversible air change. The heated air is blown from inside the building out through the regenerator. In this way the regenerator accumulates the heat in the air. Over a period of 30-120 seconds, the regenerator capacity is utilized. When the regenerator cannot be further heated, the air flow is reversed and there is now blown cold air through the regenerator. Thereby the heat from the regenerator is released to the cold fresh air. Thus, the fresh air brings heat back into the building, whereby the air is replaced with a limited heat loss. Ventilation with a regenerator is described as micro-ventilation. The developed micro-ventilation unit was tested by the Danish Technological Institute. The test results shows that the unit performs according to expectations: 1) The heat recovery is 85%; 2) The flow through the unit is 80m3 per hour in a 5 section unit; 3) The noise level is 30 db(A) in a representative room; 4) The energy consumption is <300 J/m3. The unit is introduced into the market, and the first plants have been sold. (LN)

  14. Particle deposition in ventilation ducts

    Energy Technology Data Exchange (ETDEWEB)

    Sippola, Mark Raymond [Univ. of California, Berkeley, CA (United States)

    2002-09-01

    Exposure to airborne particles is detrimental to human health and indoor exposures dominate total exposures for most people. The accidental or intentional release of aerosolized chemical and biological agents within or near a building can lead to exposures of building occupants to hazardous agents and costly building remediation. Particle deposition in heating, ventilation and air-conditioning (HVAC) systems may significantly influence exposures to particles indoors, diminish HVAC performance and lead to secondary pollutant release within buildings. This dissertation advances the understanding of particle behavior in HVAC systems and the fates of indoor particles by means of experiments and modeling. Laboratory experiments were conducted to quantify particle deposition rates in horizontal ventilation ducts using real HVAC materials. Particle deposition experiments were conducted in steel and internally insulated ducts at air speeds typically found in ventilation ducts, 2-9 m/s. Behaviors of monodisperse particles with diameters in the size range 1-16 μm were investigated. Deposition rates were measured in straight ducts with a fully developed turbulent flow profile, straight ducts with a developing turbulent flow profile, in duct bends and at S-connector pieces located at duct junctions. In straight ducts with fully developed turbulence, experiments showed deposition rates to be highest at duct floors, intermediate at duct walls, and lowest at duct ceilings. Deposition rates to a given surface increased with an increase in particle size or air speed. Deposition was much higher in internally insulated ducts than in uninsulated steel ducts. In most cases, deposition in straight ducts with developing turbulence, in duct bends and at S-connectors at duct junctions was higher than in straight ducts with fully developed turbulence. Measured deposition rates were generally higher than predicted by published models. A model incorporating empirical equations based on the

  15. Livestock metabolomics and the livestock metabolome: A systematic review.

    Science.gov (United States)

    Goldansaz, Seyed Ali; Guo, An Chi; Sajed, Tanvir; Steele, Michael A; Plastow, Graham S; Wishart, David S

    2017-01-01

    Metabolomics uses advanced analytical chemistry techniques to comprehensively measure large numbers of small molecule metabolites in cells, tissues and biofluids. The ability to rapidly detect and quantify hundreds or even thousands of metabolites within a single sample is helping scientists paint a far more complete picture of system-wide metabolism and biology. Metabolomics is also allowing researchers to focus on measuring the end-products of complex, hard-to-decipher genetic, epigenetic and environmental interactions. As a result, metabolomics has become an increasingly popular "omics" approach to assist with the robust phenotypic characterization of humans, crop plants and model organisms. Indeed, metabolomics is now routinely used in biomedical, nutritional and crop research. It is also being increasingly used in livestock research and livestock monitoring. The purpose of this systematic review is to quantitatively and objectively summarize the current status of livestock metabolomics and to identify emerging trends, preferred technologies and important gaps in the field. In conducting this review we also critically assessed the applications of livestock metabolomics in key areas such as animal health assessment, disease diagnosis, bioproduct characterization and biomarker discovery for highly desirable economic traits (i.e., feed efficiency, growth potential and milk production). A secondary goal of this critical review was to compile data on the known composition of the livestock metabolome (for 5 of the most common livestock species namely cattle, sheep, goats, horses and pigs). These data have been made available through an open access, comprehensive livestock metabolome database (LMDB, available at http://www.lmdb.ca). The LMDB should enable livestock researchers and producers to conduct more targeted metabolomic studies and to identify where further metabolome coverage is needed.

  16. Livestock metabolomics and the livestock metabolome: A systematic review.

    Directory of Open Access Journals (Sweden)

    Seyed Ali Goldansaz

    Full Text Available Metabolomics uses advanced analytical chemistry techniques to comprehensively measure large numbers of small molecule metabolites in cells, tissues and biofluids. The ability to rapidly detect and quantify hundreds or even thousands of metabolites within a single sample is helping scientists paint a far more complete picture of system-wide metabolism and biology. Metabolomics is also allowing researchers to focus on measuring the end-products of complex, hard-to-decipher genetic, epigenetic and environmental interactions. As a result, metabolomics has become an increasingly popular "omics" approach to assist with the robust phenotypic characterization of humans, crop plants and model organisms. Indeed, metabolomics is now routinely used in biomedical, nutritional and crop research. It is also being increasingly used in livestock research and livestock monitoring. The purpose of this systematic review is to quantitatively and objectively summarize the current status of livestock metabolomics and to identify emerging trends, preferred technologies and important gaps in the field. In conducting this review we also critically assessed the applications of livestock metabolomics in key areas such as animal health assessment, disease diagnosis, bioproduct characterization and biomarker discovery for highly desirable economic traits (i.e., feed efficiency, growth potential and milk production. A secondary goal of this critical review was to compile data on the known composition of the livestock metabolome (for 5 of the most common livestock species namely cattle, sheep, goats, horses and pigs. These data have been made available through an open access, comprehensive livestock metabolome database (LMDB, available at http://www.lmdb.ca. The LMDB should enable livestock researchers and producers to conduct more targeted metabolomic studies and to identify where further metabolome coverage is needed.

  17. Sensor-based demand controlled ventilation

    Energy Technology Data Exchange (ETDEWEB)

    De Almeida, A.T. [Universidade de Coimbra (Portugal). Dep. Eng. Electrotecnica; Fisk, W.J. [Lawrence Berkeley National Lab., CA (United States)

    1997-07-01

    In most buildings, occupancy and indoor pollutant emission rates vary with time. With sensor-based demand-controlled ventilation (SBDCV), the rate of ventilation (i.e., rate of outside air supply) also varies with time to compensate for the changes in pollutant generation. In other words, SBDCV involves the application of sensing, feedback and control to modulate ventilation. Compared to ventilation without feedback, SBDCV offers two potential advantages: (1) better control of indoor pollutant concentrations; and (2) lower energy use and peak energy demand. SBDCV has the potential to improve indoor air quality by increasing the rate of ventilation when indoor pollutant generation rates are high and occupants are present. SBDCV can also save energy by decreasing the rate of ventilation when indoor pollutant generation rates are low or occupants are absent. After providing background information on indoor air quality and ventilation, this report provides a relatively comprehensive discussion of SBDCV. Topics covered in the report include basic principles of SBDCV, sensor technologies, technologies for controlling air flow rates, case studies of SBDCV, application of SBDCV to laboratory buildings, and research needs. SBDCV appears to be an increasingly attractive technology option. Based on the review of literature and theoretical considerations, the application of SBDCV has the potential to be cost-effective in applications with the following characteristics: (a) a single or small number of dominant pollutants, so that ventilation sufficient to control the concentration of the dominant pollutants provides effective control of all other pollutants; (b) large buildings or rooms with unpredictable temporally variable occupancy or pollutant emission; and (c) climates with high heating or cooling loads or locations with expensive energy.

  18. Patient-Ventilator Dyssynchrony

    Directory of Open Access Journals (Sweden)

    Elvira-Markela Antonogiannaki

    2017-11-01

    Full Text Available In mechanically ventilated patients, assisted mechanical ventilation (MV is employed early, following the acute phase of critical illness, in order to eliminate the detrimental effects of controlled MV, most notably the development of ventilator-induced diaphragmatic dysfunction. Nevertheless, the benefits of assisted MV are often counteracted by the development of patient-ventilator dyssynchrony. Patient-ventilator dyssynchrony occurs when either the initiation and/or termination of mechanical breath is not in time agreement with the initiation and termination of neural inspiration, respectively, or if the magnitude of mechanical assist does not respond to the patient’s respiratory demand. As patient-ventilator dyssynchrony has been associated with several adverse effects and can adversely influence patient outcome, every effort should be made to recognize and correct this occurrence at bedside. To detect patient-ventilator dyssynchronies, the physician should assess patient comfort and carefully inspect the pressure- and flow-time waveforms, available on the ventilator screen of all modern ventilators. Modern ventilators offer several modifiable settings to improve patient-ventilator interaction. New proportional modes of ventilation are also very helpful in improving patient-ventilator interaction.

  19. Measure Guideline: Ventilation Guidance for Residential High-Performance New Construction - Multifamily

    Energy Technology Data Exchange (ETDEWEB)

    Lstiburek, Joseph [Building Science Corp., Westford, MA (United States)

    2017-01-01

    The measure guideline provides ventilation guidance for residential high performance multifamily construction that incorporates the requirements of the ASHRAE 62.2 ventilation and indoor air quality standard. The measure guideline focus is on the decision criteria for weighing cost and performance of various ventilation systems. The measure guideline is intended for contractors, builders, developers, designers and building code officials. The guide may also be helpful to building owners wishing to learn more about ventilation strategies available for their buildings. The measure guideline includes specific design and installation instructions for the most cost effective and performance effective solutions for ventilation in multifamily units that satisfies the requirements of ASHRAE 62.2-2016.

  20. Mechanical ventilator - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007240.htm Mechanical ventilator - infants To use the sharing features on this page, please enable JavaScript. A mechanical ventilator is a machine that assists with breathing. ...

  1. 1992 Livestock Grazing Action Plan

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — The plan outlines a grazing program involving intensive amounts of livestock to achieve specific wildlife habitat goals and objectives during the 1993 growing...

  2. Chlamydial infections in Chinese livestock.

    Science.gov (United States)

    Yin, L; Kalmar, I D; Boden, J; Vanrompay, D

    2013-12-01

    The occurrence and impact of chlamydial infections in Western livestock is well documented in the international literature, but less is known aboutthese infections in livestock in the People's Republic of China. China's livestock production and its share in the global market have increased significantly in recent decades. In this review, the relevant English and Chinese literature on the epidemiology of chlamydial infections in Chinese livestock is considered, and biosecurity measures, prophylaxis and treatment of these infections in China's livestock are compared with Western practices. Chlamydial infections are highly prevalent in Chinese livestock and cause important economic losses, as they do in the rest of the world. Surveillance data and diagnostic results of abortion outbreaks in cattle, sheep and goats highlight the importance of virulent chlamydial infections in China's major ruminant species in many of China's provinces, autonomous regions and municipalities. Data from many of China's provincial divisions also indicate the widespread presence of chlamydial infections in industrially reared swine across the country. Less is known about chlamydial infections in yak, buffalo and horses, but available reports indicate a high prevalence in China's populations. In these reports, chlamydiosis was related to abortions in yak and pneumonia in horses. In Western countries, chlamydial infections are principally treated with antibiotics. In China, however, traditional medicine is often used in conjunction with antibiotics or used as an alternative treatment.

  3. Why we ventilate our houses - An historical look

    Energy Technology Data Exchange (ETDEWEB)

    Matson, Nance E.; Sherman, Max H.

    2004-05-14

    The knowledge of how to ventilate buildings, and how much ventilation is necessary for human health and comfort, has evolved over centuries of trial and error. Humans and animals have developed successful solutions to the problems of regulating temperature and removing air pollutants through the use of ventilation. These solutions include ingenious construction methods, such as engineered passive ventilation (termite mounds and passive stacks), mechanical means (wing-powered, fans), and an evolving effort to identify problems and develop solutions. Ventilation can do more than help prevent building occupants from getting sick; it can provide an improved indoor environment. Codes and standards provide minimum legal requirements for ventilation, but the need for ventilation goes beyond code minima. In this paper we will look at indoor air pollutant sources over time, the evolution of ventilation strategies, current residential ventilation codes and standards (e.g., recently approved ASHRAE Standard 62.2), and briefly discuss ways in which we can go beyond the standards to optimize residential ventilation, reduce indoor air quality problems, and provide corresponding social and economic benefit.

  4. Monitoring results and analysis of thermal comfort conditions in experimental buildings for different heating systems and ventilation regimes during heating and cooling seasons

    Science.gov (United States)

    Gendelis, S.; Jakovičs, A.; Ratnieks, J.; Bandeniece, L.

    2017-10-01

    This paper focuses on the long-term monitoring of thermal comfort and discomfort parameters in five small test buildings equipped with different heating and cooling systems. Calculations of predicted percentage of dissatisfied people (PPD) index and discomfort factors are provided for the room in winter season running three different heating systems – electric heater, air-air heat pump and air-water heat pump, as well as for the summer cooling with split type air conditioning systems. It is shown that the type of heating/cooling system and its working regime has an important impact on thermal comfort conditions in observed room. Recommendations for the optimal operating regimes and choice of the heating system from the thermal comfort point of view are summarized.

  5. Infiltration as Ventilation: Weather-Induced Dilution

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Turner, William J.N. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2011-06-01

    The purpose of outdoor air ventilation is to dilute or remove indoor contaminants to which occupants are exposed. It can be provided by mechanical or natural means. In most homes, especially older homes, weather-driven infiltration provides the dominant fraction of the total ventilation. As we seek to provide good indoor air quality at minimum energy cost, it is important to neither over-ventilate nor under-ventilate. Thus, it becomes critically important to evaluate correctly the contribution infiltration makes to the total outdoor air ventilation rate. Because weather-driven infiltration is dependent on building air leakage and weather-induced pressure differences, a given amount of air leakage will provide different amounts of infiltration. Varying rates of infiltration will provide different levels of contaminant dilution and hence effective ventilation. This paper derives these interactions and then calculates the impact of weather-driven infiltration for different climates. A new “N-factor” is introduced to provide a convenient method for calculating the ventilation contribution of infiltration for over 1,000 locations across North America. The results of this work could be used in indoor air quality standards (specifically ASHRAE 62.2) to account for the contribution of weather-driven infiltration towards the dilution of indoor pollutants.

  6. Building Assessment Survey and Evaluation Study Summarized Data - HVAC Characteristics

    Science.gov (United States)

    In the Building Assessment Survey and Evaluation (BASE) Study Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues was acquired by examining the building plans, conducting a building walk-through, and speaking with the building owner, manager, and/or operator.

  7. Effect of Ventilation Strategies on Residential Ozone Levels

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Sherman, Max H. [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2012-08-01

    Elevated outdoor ozone levels are associated with adverse health effects. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone of outdoor origin would lower population exposures and might also lead to a reduction in ozone-associated adverse health effects. In most buildings, indoor ozone levels are diminished with respect to outdoor levels to an extent that depends on surface reactions and on the degree to which ozone penetrates the building envelope. Ozone enters buildings from outdoors together with the airflows that are driven by natural and mechanical means, including deliberate ventilation used to reduce concentrations of indoor-generated pollutants. When assessing the effect of deliberate ventilation on occupant health one should consider not only the positive effects on removing pollutants of indoor origin but also the possibility that enhanced ventilation might increase indoor levels of pollutants originating outdoors. This study considers how changes in residential ventilation that are designed to comply with ASHRAE Standard 62.2 might influence indoor levels of ozone. Simulation results show that the building envelope can contribute significantly to filtration of ozone. Consequently, the use of exhaust ventilation systems is predicted to produce lower indoor ozone concentrations than would occur with balanced ventilation systems operating at the same air-­exchange rate. We also investigated a strategy for reducing exposure to ozone that would deliberately reduce ventilation rates during times of high outdoor ozone concentration while still meeting daily average ventilation requirements.

  8. Go with the Flow: Principles and examples of natural ventilation

    NARCIS (Netherlands)

    Van Agtmaal, B.

    2011-01-01

    This "designers' manual" is made during the TIDO-course AR0531 Smart & Bioclimatic Design. With an increasing need for more sustainable buildings, natural ventilation presents us with a low-energy and low-cost solution. This manual inspires designers to apply natural ventilation, by offering

  9. Impact of intensification of different types of livestock production in smallholder crop-livestock systems

    NARCIS (Netherlands)

    Udo, H.M.J.; Aklilu, H.A.; Phong, L.T.; Bosma, R.H.; Budisatria, I.G.S.; Patil, B.R.; Samdup, T.; Bebe, B.O.

    2011-01-01

    Intensification of livestock production is widely advocated to meet the increasing demands for livestock products and to contribute to improving the livelihoods of rural households. This paper discusses the impact of livestock intensification on smallholder farms using village poultry, integrated

  10. Improving comfort and health with personalized ventilation

    DEFF Research Database (Denmark)

    Melikov, Arsen Krikor

    2004-01-01

    The thermal environment and air quality in buildings affects occupants¿ health, comfort and performance. The heating, ventilating and air-conditioning (HVAC) of buildings today is designed to provide a uniform room environment. However, large individual differences exist between occupants in regard...... microenvironment. Furthermore, HVAC systems should be designed to protect occupants from airborne transmission of infectious agents that may be present in exhaled air. Personalized ventilation is a new development in the field of HVAC and has the potential to fulfil the above requirements. This paper reviews...... existing knowledge on performance of personalized ventilation (PV) and on human response to it. The airflow interaction in the vicinity of the human body is analysed and its impact on thermal comfort and inhaled air quality is discussed together with control strategies and the application of PV in practice...

  11. Natural Ventilation Driven by Wind and Temperature Difference

    DEFF Research Database (Denmark)

    Larsen, Tine Steen

    Natural ventilation is a commonly used principle when buildings are being ventilated. It can be controlled by openings in the building envelope, which open or close depending on the need of air inside the building. It can also be the simple action of just opening a door or a window to let the fresh...... air in. In both cases it is often necessary to have an idea of the amount of air coming through the window. Therefore, expressions for this prediction have been developed through the last decades. In cross-ventilation, the expressions are rather well defined and here the difficulty lies within...... the definition of the discharge coefficient that describes the characteristics of the opening, since it seems to fluctuate depending on the incidence angle of the wind. In single-sided ventilation where openings only exist in one side of the building, the flow through the opening is harder to predict. The main...

  12. Energy and IAQ Implications of Residential Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Turner, William [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States); Walker, Iain [Lawrence Berkeley National Lab. (LBNL), Berkeley, CA (United States)

    2014-08-01

    This study evaluates the energy, humidity and indoor air quality (IAQ) implications of residential ventilation cooling in all U.S. IECC climate zones. A computer modeling approach was adopted, using an advanced residential building simulation tool with airflow, energy and humidity models. An economizer (large supply fan) was simulated to provide ventilation cooling while outdoor air temperatures were lower than indoor air temperatures (typically at night). The simulations were performed for a full year using one-minute time steps to allow for scheduling of ventilation systems and to account for interactions between ventilation and heating/cooling systems.

  13. Mechanical ventilation with heat recovery in cold climates

    DEFF Research Database (Denmark)

    Kragh, Jesper; Rose, Jørgen; Svendsen, Svend

    2005-01-01

    like the Northern Europe or in arctic climate like in Greenland or Alaska these ventilation systems will typically face problems with ice formation in the heat exchanger. When the warm humid room air comes in contact with the cold surfaces inside the exchanger (cooled by the outside air), the moisture......Building ventilation is necessary to achieve a healthy and comfortable indoor environment, but as energy prices continue to rise it is necessary to reduce the energy consumption. Using mechanical ventilation with heat recovery reduces the ventilation heat loss significantly, but in cold climates...

  14. Method to assess the performance of ventilation systems in dwellings considering the influence of uncertainties

    NARCIS (Netherlands)

    Yang, Z.; Cauberg, J.J.M.; Tenpierik, M.J.

    2011-01-01

    Normally, the design of a ventilation system in a dwelling is based on national regulations, related design rules, building tradition and general knowledge about healthy indoor air quality, ventilation and air handling units. In practice, the actual performance of ventilation systems is determined

  15. Complications of mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Drašković Biljana

    2011-01-01

    Full Text Available Mechanical ventilation of the lungs, as an important therapeutic measure, cannot be avoided in critically ill patients. However, when machines take over some of vital functions there is always a risk of complications and accidents. Complications associated with mechanical ventilation can be divided into: 1 airway-associated complications; 2 complications in the response of patients to mechanical ventilation; and 3 complications related to the patient’s response to the device for mechanical ventilation. Complications of artificial airway may be related to intubation and extubation or the endotracheal tube. Complications of mechanical ventilation, which arise because of the patient’s response to mechanical ventilation, may primarily cause significant side effects to the lungs. During the last two decades it was concluded that mechanical ventilation can worsen or cause acute lung injury. Mechanical ventilation may increase the alveolar/capillary permeability by overdistension of the lungs (volutrauma, it can exacerbate lung damage due to the recruitment/derecruitment of collapsed alveoli (atelectrauma and may cause subtle damages due to the activation of inflammatory processes (biotrauma. Complications caused by mechanical ventilation, beside those involving the lungs, can also have significant effects on other organs and organic systems, and can be a significant factor contributing to the increase of morbidity and mortality in critically ill of mechanically ventilated patients. Complications are fortunately rare and do not occur in every patient, but due to their seriousness and severity they require extensive knowledge, experience and responsibility by health-care workers.

  16. Improve train tunnel. A dynamical ventilation method

    NARCIS (Netherlands)

    Phaff, J.C.; Gids, W.F. de

    1996-01-01

    Train tunnels and subways are an interesting field of ventilation. Trains move air through tunnels at rates of 600 m3/s (over 2 x 106 m3 per hour) which is much more than flow rates in buildings. Air pressures can vary up to some 3000 Pa leading to air velocities in the range of 10 to 50 m/s. This

  17. Implementation of ventilation in existing schools

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Petersen, Steffen

    ; they evaluate both scientific and practical implementation The analyses lead to a list of criteria associated with the implementation of ventilation in existing schools. Generic retrofitting scenarios which prioritize energy savings, indoor climate and building/facade integration are assembled and illustrated...

  18. Trends in Public Library Buildings.

    Science.gov (United States)

    Holt, Raymond M.

    1987-01-01

    Review of trends in public library buildings covers cycles in building activity; financial support; site selection; expansion, remodeling, or conversion of existing buildings; size of buildings; and such architectural concerns as flexible space, lighting, power, accommodation of computer systems, heat and ventilation, fire protection, security,…

  19. The State-of-the-Art for Ventilative Cooling

    DEFF Research Database (Denmark)

    Heiselberg, Per Kvols

    2016-01-01

    Ventilative cooling for buildings may lead to cooling energy savings and improvements in thermal comfort, especially in seasonally temperate and warm climates. But, codes and regulations need to better quantify its benefits.......Ventilative cooling for buildings may lead to cooling energy savings and improvements in thermal comfort, especially in seasonally temperate and warm climates. But, codes and regulations need to better quantify its benefits....

  20. RedVent. Turned off ventilation at night in schools - risks and opportunities; RedVent. Avstaengd ventilation paa natten i skolor - risker och moejligheter

    Energy Technology Data Exchange (ETDEWEB)

    Haegerhed Engman, Linda; Fyhr, Kristina; Langer, Sarka; Ruud, Svein; Ylmen, Peter

    2011-07-01

    Reduced ventilation rates or shutdown ventilation during nights is often being used in school buildings in order to save energy and can decrease the energy cost for heating and ventilation with at least 30 %. Swedish Building Regulations (BBR) allows reduced ventilation flow in non-residential buildings when no one is using the building but it must not give rise to adverse health effects or damage the building or its installations. Potential risks are mould- and moisture damages and indoor air quality problems. Another question is whether the shut down itself might lead to indoor air quality problems due to chemical reactions between outdoor air and indoor emissions built-up during the night. The study was divided into three steps; an interview with property managers and care-taker, calculations of energy saving potentials and a field study. Measurements were per-formed in one classroom for two weeks in April 2010. Different set-ups for ventilation flow during night time and air tightness of the building envelope were studied; ventilation shut down, intermittent ventilation (15 min every second hour) and continuous full speed ventilation during night. In the studied classroom, shutdown ventilation during nights did not significantly affect the indoor air quality in the classroom during the school day even though there were effects seen during the night. We found a somewhat higher moisture accumulation those nights when the ventilation was shut down and some fractions of particles during intermittent ventilation compared to continues full ventilation during night time. This specific school and classroom were well ventilated and there was no moisture supply from new building material or other types of moisture producing activities. Schools with lower day-time ventilation rates, moisture in building construction, IAQ- or dampness problems as well as buildings close to heavy traffic should analyse the conditions for the specific building before reducing ventilation to

  1. Livestock Fadama users' access to information on selected livestock ...

    African Journals Online (AJOL)

    The FUGs members never had access to information on key livestock technologies like artificial insemination, automated feeding, feed formulation and creep feeding. Farmers' number of years of formal education (r = -0.09) and family size (r= 0.09) had no significant relationships with respondents' access to information on ...

  2. Best available technology for European livestock farms

    DEFF Research Database (Denmark)

    Loyon, L.; Burton, C. H.; Misselbrook, T.

    2016-01-01

    Concerns over the negative environmental impact from livestock farming across Europe continue to make their mark resulting in new legislation and large research programs. However, despite a huge amount of published material and many available techniques, doubts over the success of national...... and European initiatives remain. Uptake of the more cost-effective and environmentally-friendly farming methods (such as dietary control, building design and good manure management) is already widespread but unlikely to be enough in itself to ensure that current environmental targets are fully met. Some......, the efficacies of many of the current BAT-listed options are modest, difficult to regulate and in some cases they may even be counterproductive with respect to other objectives ie pollution swapping. Evaluation of the existing and new BAT technologies is a key to a successful abatement of pollution from...

  3. Performance of personalized ventilation combined with chilled ceiling in an office room: inhaled air quality and contaminant distribution

    DEFF Research Database (Denmark)

    Lipczynska, Aleksandra; Kaczmarczyk, Jan; Melikov, Arsen Krikor

    2014-01-01

    In a simulated two persons’ office room inhaled air quality and contaminant distribution provided with personalized ventilation combined with chilled ceiling, mixing ventilation only, chilled ceiling with mixing ventilation and chilled ceiling with mixing and personalized ventilation was studied...... people (exhaled air, bioeffluents) and building materials (wall painting). Personalized ventilation combined with chilled ceiling ensured highest air quality at the workstation under all conditions. Pollutant concentration in the occupied zone away from the workstations did not differ substantially...... between the tested systems. Chilled ceiling combined with personalized ventilation working as the only air supplying system may be optimal solution in many buildings....

  4. Mechanical ventilation in children.

    Science.gov (United States)

    Kendirli, Tanil; Kavaz, Asli; Yalaki, Zahide; Oztürk Hişmi, Burcu; Derelli, Emel; Ince, Erdal

    2006-01-01

    Mechanical ventilation can be lifesaving, but > 50% of complications in conditions that require intensive care are related to ventilatory support, particularly if it is prolonged. We retrospectively evaluated the medical records of patients who had mechanical ventilation in the Pediatric Intensive Care Unit (PICU) during a follow-up period between January 2002-May 2005. Medical records of 407 patients were reviewed. Ninety-one patients (22.3%) were treated with mechanical ventilation. Ages of all patients were between 1-180 (median: 8) months. The mechanical ventilation time was 18.8 +/- 14.1 days. Indication of mechanical ventilation could be divided into four groups as respiratory failure (64.8%), cardiovascular failure (19.7%), central nervous system disease (9.8%) and safety airway (5.4%). Tracheostomy was performed in four patients. The complication ratio of mechanically ventilated children was 42.8%, and diversity of complications was as follows: 26.3% atelectasia, 17.5% ventilator-associated pneumonia, 13.1% pneumothorax, 5.4% bleeding, 4.3% tracheal edema, and 2.1% chronic lung disease. The mortality rate of mechanically ventilated patients was 58.3%, but the overall mortality rate in the PICU was 12.2%. In conclusion, there are few published epidemiological data on the follow-up results and mortality in infants and children who are mechanically ventilated.

  5. Natural Ventilation in Atria

    DEFF Research Database (Denmark)

    Svidt, Kjeld; Heiselberg, Per; Hendriksen, Ole Juhl

    This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions.......This case study comprises a monitoring programme as well as a Computational Fluid Dynamics (CFD) analysis of a natural ventilated atrium. The purpose has been to analyse the performance of a typical natural ventilation system in Denmark under both summer and winter conditions....

  6. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [Building Science Corporation, Somerville, MA (United States); Bergey, Daniel [Building Science Corporation, Somerville, MA (United States)

    2014-02-01

    In this project, Building America research team Building Science Corporation tested the effectiveness of ventilation systems at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. This was because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four system factor categories: balance, distribution, outside air source, and recirculation filtration. Recommended system factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  7. LIVESTOCK MARKETS IN JIGAWA STATE

    African Journals Online (AJOL)

    *Department of Parasitology and Entomology, Faculty of Veterinary Medicine,. Ahmadu Bello University, Zaria. *"Department of Veterinary and Livestock Services,. Ministry of Agriculture and Natural Resources, Kano State. SUMMARY. A survey was conducted between October 1995 and September 2000 in which a total of ...

  8. SIZE OF LIVESTOCK AGRICULTURAL OPERATIONS

    Directory of Open Access Journals (Sweden)

    Bazbanela Stere

    2015-07-01

    Full Text Available The main goal of the paper is to map the performance of Romanian farms from the perspective of livestock agricultural operations using principal component analysis technique (PCA and similarities between Romania and other countries from UE. The empirical results reveal that animal breedings farms are grouped into two categories :small and middle sized farms ; and the fact that Romania , one of Europe’s major forces in the field of livestock husbandry, has come to be one of the biggest importers of food products, although, by tradition, it is one of the continent’s countries with ideal conditions for breeding all species of animals. When clustering the countries we observ that in countries such as Greece, Italy, Portugal, Spain, cow farms, for example, do not exceed 10-16 heads and in Holland, England, Denmark, Belgium and France, the average farm size reaches 30-70 heads of milk cows. The cluster analysis revealed that in livestock operations, animal stock is the one that generates production, while the animal number indicates the size of the livestock unit.

  9. Gender, Livestock and Asset Ownership

    International Development Research Centre (IDRC) Digital Library (Canada)

    can easily own and are not bound by complex property rights. • Women may own livestock, acquired through the market or inheritance before or during marriage .... depending on the cultural context as well as the production system. To cope with this complexity, compiling information on the rights that women have over their ...

  10. Thermoregulation and ventilation of termite mounds

    Science.gov (United States)

    Korb, Judith

    2003-05-01

    Some of the most sophisticated of all animal-built structures are the mounds of African termites of the subfamily Macrotermitinae, the fungus-growing termites. They have long been studied as fascinating textbook examples of thermoregulation or ventilation of animal buildings. However, little research has been designed to provide critical tests of these paradigms, derived from a very small number of original papers. Here I review results from recent studies on Macrotermes bellicosus that considered the interdependence of ambient temperature, thermoregulation, ventilation and mound architecture, and that question some of the fundamental paradigms of termite mounds. M. bellicosus achieves thermal homeostasis within the mound, but ambient temperature has an influence too. In colonies in comparably cool habitats, mound architecture is adapted to reduce the loss of metabolically produced heat to the environment. While this has no negative consequences in small colonies, it produces a trade-off with gas exchange in large colonies, resulting in suboptimally low nest temperatures and increased CO2 concentrations. Along with the alteration in mound architecture, the gas exchange/ventilation mechanism also changes. While mounds in the thermally appropriate savannah have a very efficient circular ventilation during the day, the ventilation in the cooler forest is a less efficient upward movement of air, with gas exchange restricted by reduced surface exchange area. These results, together with other recent findings, question entrenched ideas such as the thermosiphon-ventilation mechanism or the assumption that mounds function to dissipate internally produced heat. Models trying to explain the proximate mechanisms of mound building, or building elements, are discussed.

  11. Impact of Residential Mechanical Ventilation on Energy Cost and Humidity Control

    Energy Technology Data Exchange (ETDEWEB)

    Martin, Eric [Building Science Corporation, Westford, MA (United States)

    2014-01-01

    Optimizing whole house mechanical ventilation as part of the Building Ameerica program's systems engineered approach to constructing housing has been an important subject of the program's research. Ventilation in residential buildings is one component of an effective, comprehensive strategy for creation and maintenance of a comfortable and healthy indoor air environment. The study described in this report is based on building energy modeling with an important focus on the indoor humidity impacts of ventilation. The modeling tools used were EnergyPlus version 7.1 (E+) and EnergyGauge USA (EGUSA). Twelve U.S. cities and five climate zones were represented. A total of 864 simulations (2*2*3*3*12= 864) were run using two building archetypes, two building leakage rates, two building orientations, three ventilation systems, three ventilation rates, and twelve climates.

  12. Numerical estimation of natural ventilation of cubical urban arrays with different packing density

    Directory of Open Access Journals (Sweden)

    Shuhaimi Saidatul Sharin

    2017-01-01

    Full Text Available In an urban environment where buildings are closely packed, natural ventilation performance is undesirably disturbed by the effect of surrounding buildings. Cross-ventilation refers to the regulation of air within a building, which is essential in providing good air quality and thermal comfort for the occupants. Thus, this study focuses on the impact of packing density on ventilation rate of cross-ventilated buildings. The numerical estimation is performed by means of computational fluid dynamic (CFD using the Reynolds Averaged Navier-Stokes (RANS with RNG k – ε (RNG turbulence model. Three configurations of simplified generic cubes which are regularly aligned with packing density of 25%, 35%, and 50% were considered. Velocity distribution around and inside the buildings as well as the ventilation rate are analysed. The case with packing density of 25% exhibits a reduction of 90% in the ventilation rate compared to the isolated case and continues to decrease as the packing density increase up to 35%. However, further increase of packing density up to 50%, slightly increases the ventilation rate. Hence, the result of this study imposed that surrounding buildings have a substantial influence on ventilation performance of cross-ventilated buildings.

  13. LARGE BUILDING RADON MANUAL

    Science.gov (United States)

    The report summarizes information on how bilding systems -- especially the heating, ventilating, and air-conditioning (HVAC) system -- inclurence radon entry into large buildings and can be used to mitigate radon problems. It addresses the fundamentals of large building HVAC syst...

  14. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  15. Livestock Vaccine Innovation Fund | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    The Livestock Vaccine Innovation Fund (LVIF) seeks to improve the health of livestock and the livelihoods of farmers by supporting the development, production, and commercialization of innovative vaccines against neglected livestock diseases (including poultry) in sub-Saharan Africa, South and Southeast Asia.

  16. Livestock Farming Under Climate Change Conditions

    CSIR Research Space (South Africa)

    Koelle, B

    2016-12-01

    Full Text Available This book is intended for livestock farmers, as well as others who are wanting to learn about livestock farming. It is not intended to be a comprehensive livestock farming manual, but is rather aimed at giving some guidance on how to plan...

  17. Sustainable livestock farming as normative practice

    NARCIS (Netherlands)

    Rademaker, Corné J.; Glas, Gerrit; Jochemsen, Henk

    2017-01-01

    We argue that an understanding of livestock farming as normative practice clarifies how sustainability is to be understood in livestock farming. The sustainability of livestock farming is first approached by investigating its identity. We argue that the economic aspect qualifies and the formative

  18. 25 CFR 700.725 - Livestock trespass.

    Science.gov (United States)

    2010-04-01

    ... according to the range unit Range Management Plan. (c) The grazing of livestock upon any land withdrawn from... approved by the Commissioner. (e) Grazing of livestock whose brand is not recorded in the range unit Range Management Plan. The owner of any livestock grazing in trespass on the New Lands is liable to a civil penalty...

  19. MODELING OF INDICATORS OF LIVESTOCK IN RUSSIA

    Directory of Open Access Journals (Sweden)

    Ekaterina S. Darda

    2014-01-01

    Full Text Available The role of livestock in food without dangerous country. The analysis of the dynamics of production indicators waspsmainly livestock products. The problems offorecasting-ing performance of LivestockDevelopment of the Russian Federationon the basis of the a-analytical models ofalignment and connected series.

  20. Mainstreaming gender issues in livestock research | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-06-06

    Jun 6, 2016 ... Read more about how to mainstream gender considerations into livestock development projects in the Gender Responsive Livestock Research brief (PDF, 613KB, available in English only). This document summarizes findings presented in the book “Women, Livestock Ownership and Markets: Bridging the ...

  1. Energy efficient ventilation based on demand humidity control. Demonstration project with 49 apartments in Soenderborg

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-09-01

    The aim of the project is to demonstrate how the overall energy consumption in apartment buildings can be reduced through a combination of: 1) Energy efficient ventilation based on demand humidity control; 2) Energy efficient design of the building shell including passive solar and seasonally flexible sunspaces; 3) Use of low temperature heating system. The 3 blocks in the project, each with 16 apartments, are furnished with 3 different ventilation systems: 1) Standard exhaust system according to building codes; 2) Ventilation system with humidity control. Each room is furnished with an air inlet valve controlled by a processor, which monitors the humidity; 3) Standard ventilation system with heat recovery. (au)

  2. VENTILATION MODEL REPORT

    Energy Technology Data Exchange (ETDEWEB)

    V. Chipman

    2002-10-31

    The purpose of the Ventilation Model is to simulate the heat transfer processes in and around waste emplacement drifts during periods of forced ventilation. The model evaluates the effects of emplacement drift ventilation on the thermal conditions in the emplacement drifts and surrounding rock mass, and calculates the heat removal by ventilation as a measure of the viability of ventilation to delay the onset of peak repository temperature and reduce its magnitude. The heat removal by ventilation is temporally and spatially dependent, and is expressed as the fraction of heat carried away by the ventilation air compared to the fraction of heat produced by radionuclide decay. One minus the heat removal is called the wall heat fraction, or the remaining amount of heat that is transferred via conduction to the surrounding rock mass. Downstream models, such as the ''Multiscale Thermohydrologic Model'' (BSC 2001), use the wall heat fractions as outputted from the Ventilation Model to initialize their postclosure analyses.

  3. Experimental Investigation of Convective Heat Transfer during Night Cooling with Different Ventilation Systems and Surface Emissivities

    DEFF Research Database (Denmark)

    Le Dreau, Jerome; Heiselberg, Per; Jensen, Rasmus Lund

    2013-01-01

    Night-time ventilation is a promising approach to reduce the energy needed for cooling buildings without reducing thermal comfort. Nevertheless actual building simulation tools have showed their limits in predicting accurately the efficiency of night-time ventilation, mainly due to inappropriate ...

  4. Reducing the ingress of urban noise through natural ventilation openings.

    Science.gov (United States)

    Oldham, D J; de Salis, M H; Sharples, S

    2004-01-01

    For buildings in busy urban areas affected by high levels of road traffic noise the potential to use natural ventilation can be limited by excessive noise entering through ventilation openings. This paper is concerned with techniques to reduce noise ingress into naturally ventilated buildings while minimizing airflow path resistance. A combined experimental and theoretical approach to the interaction of airflow and sound transmission through ventilators for natural ventilation applications is described. A key element of the investigation has been the development of testing facilities capable of measuring the airflow and sound transmission losses for a range of ventilation noise control strategies. It is demonstrated that a combination of sound reduction mechanisms -- one covering low frequency sound and another covering high frequency sound -- is required to attenuate effectively noise from typical urban sources. A method is proposed for quantifying the acoustic performance of different strategies to enable comparisons and informed decisions to be made leading to the possibility of a design methodology for optimizing the ventilation and acoustic performance of different strategies. The need for employing techniques for combating low frequency sound in tandem with techniques for reducing high frequency sound in reducing the ingress of noise from urban sources such as road traffic to acceptable levels is demonstrated. A technique is proposed for enabling the acoustic and airflow performance of apertures for natural ventilation systems to be designed simultaneously.

  5. Ventilator waveform interpretation in mechanically ventilated small animals.

    Science.gov (United States)

    Corona, Terry M; Aumann, Marcel

    2011-10-01

    To review the topic of ventilator waveforms analysis with emphasis on interpretation of ventilator waveforms and their use in the management and monitoring of mechanically ventilated small animal patients. Human clinical studies, scientific reviews, and textbooks, as well as veterinary textbooks and clinical examples of ventilator waveforms in mechanically ventilated dogs. Ventilator waveforms are graphic representations of data collected from the ventilator and reflect patient-ventilator interactions. The 4 parameters pressure, volume, flow, and time are most descriptive of mechanical ventilation. Typically, 3 different graphs, also referred to as scalars, consisting of pressure versus time, volume versus time, and flow versus time, with time always plotted on the x-axis, are used. Changes in the ventilator settings as well as in the characteristics of the lungs such as airway resistance (R(aw)) and respiratory system compliance (C(rs)) can be recognized from specific variations in the waveforms. Flow-volume and pressure-volume loops provide additional information about changes in lung function. Patient-ventilator dyssynchrony is a common problem during mechanical ventilation and can lead to patient discomfort and an increased work of breathing. Ventilator waveforms are helpful to identify dyssynchrony, which can be divided into trigger, flow, cycle, and expiratory dyssynchrony. Ventilator waveforms allow the clinician to assess changes in respiratory mechanics, and can be useful in monitoring the progression of disease pathology and response to therapy. Adjustments in ventilator settings based on proper analysis and interpretation of these waveforms can help the clinician to optimize ventilation therapy. Ventilator waveforms are graphic representations of patient-ventilator interactions. Proper interpretation of ventilator waveforms affords the critical care clinician a better understanding of the patient's respiratory function, response to therapy, and causes

  6. Energy Analysis of the Ductless Personalized Ventilation

    DEFF Research Database (Denmark)

    Lelong, Cyril; Dalewski, Mariusz; Melikov, Arsen Krikor

    2013-01-01

    This study explores the impact of different occupancy profiles on the potential energy savings due to using ductless personalized ventilation (DPV) combined with displacement ventilation. Energy simulations were performed with the dynamic simulation software IDA-ICE in order to investigate optimal...... energy efficient strategies for implantation of DPV in practice. The impact of using DPV on annual energy use has been studied for different occupancy profiles in cold climates. The results suggest that using DPV combined with displacement ventilation may significantly reduce building energy use while...... providing good air quality and thermal comfort for the occupants. Matching DPV use with occupants’ presence at their workplaces may allow reducing the energy use of DPV significantly....

  7. Performance of displacement ventilation in practice

    DEFF Research Database (Denmark)

    Naidenov, K.; Pitchurov, G.; Langkilde, Gunnar

    2002-01-01

    This paper presents results of a field study in offices with displacement ventilation. It comprises detailed physical measurements of the thermal environment and collection of occupants´ response at 227 workplaces. The results, both physical measurements and human response, identified draught...... as the major local discomfort in the rooms with displacement ventilation. Twenty-three percent of the occupants were daily bothered by draught. In some buildings the maintenance personnel tried to improve occupants´ thermal comfort by raising the supply air temperature or office workers themselves blocked...... the diffusers by rearranging the furniture. Half of the surveyed occupants were not satisfied with the indoor air quality. The main conclusion is that displacement ventilation needs careful design and room furnishing in order to ensure a comfortable environment. Occupants must understand the underlying...

  8. Energy efficiency buildings program, FY 1980

    Energy Technology Data Exchange (ETDEWEB)

    1981-05-01

    A separate abstract was prepared on research progress in each group at LBL in the energy efficient buildings program. Two separate abstracts were prepared for the Windows and Lighting Program. Abstracts prepared on other programs are: Energy Performance of Buildings; Building Ventilation and Indoor Air Quality Program; DOE-21 Building Energy Analysis; and Building Energy Data Compilation, Analysis, and Demonstration. (MCW)

  9. Mechanical Ventilation Antioxidant Trial.

    Science.gov (United States)

    Howe, Kimberly P; Clochesy, John M; Goldstein, Lawrence S; Owen, Hugh

    2015-09-01

    Many patients each year require prolonged mechanical ventilation. Inflammatory processes may prevent successful weaning, and evidence indicates that mechanical ventilation induces oxidative stress in the diaphragm, resulting in atrophy and contractile dysfunction of diaphragmatic myofibers. Antioxidant supplementation might mitigate the harmful effects of the oxidative stress induced by mechanical ventilation. To test the clinical effectiveness of antioxidant supplementation in reducing the duration of mechanical ventilation. A randomized, prospective, placebo-controlled double-blind design was used to test whether enterally administered antioxidant supplementation would decrease the duration of mechanical ventilation, all-cause mortality, and length of stay in the intensive care unit and hospital. Patients received vitamin C 1000 mg plus vitamin E 1000 IU, vitamin C 1000 mg plus vitamin E 1000 IU plus N-acetylcysteine 400 mg, or placebo solution as a bolus injection via their enteral feeding tube every 8 hours. Clinical and statistically significant differences in duration of mechanical ventilation were seen among the 3 groups (Mantel-Cox log rank statistic = 5.69, df = 1, P = .017). The 3 groups did not differ significantly in all-cause mortality during hospitalization or in the length of stay in the intensive care unit or hospital. Enteral administration of antioxidants is a simple, safe, inexpensive, and effective intervention that decreases the duration of mechanical ventilation in critically ill adults. ©2015 American Association of Critical-Care Nurses.

  10. Chaos in Ocean Ventilation

    Science.gov (United States)

    MacGilchrist, G. A.; Marshall, D. P.; Johnson, H. L.; Lique, C.; Thomas, M. D.

    2016-02-01

    Ventilation of the subtropical ocean is important for setting the ocean stratification, the oceanic cycling of biogeochemical elements and the storage of carbon dioxide and heat on inter-annual to decadal timescales. In the textbook view, subtropical ocean ventilation is achieved through advection by the time-mean gyre circulation, with fluid parcels moving along sloping density surfaces into the ocean interior. At the same time, it is well accepted that the ocean circulation is highly nonlinear, with the kinetic energy budget dominated by mesoscale eddies. Consequently, ventilated fluid parcels, rather than remaining coherent as they move into the ocean interior, will be rapidly strained and stirred into surrounding water. To investigate the role of this nonlinear circulation in the ventilation process, we calculate a non-dimensional `filamentation number' - the ratio of the Lagrangian ventilation timescale and the timescale of strain by the nonlinear flow - across two density surfaces in the subtropical North Atlantic in an ocean circulation model. This number predicts the filament width of a ventilated fluid parcel, and is found to be large across both density surfaces (indicating small filament width), particularly on the deeper surface. A Lagrangian mapping from distributions of particles to the year in which they were ventilated is thus shown to be highly chaotic, with particles located side-by-side having been ventilated decades apart, even where the density surface is close to the ocean surface. This novel Lagrangian approach avoids the loss of information through diffusion, and emphasises the importance of mesoscale eddies in the ventilation of the subtropical ocean.

  11. Sick building syndrome

    OpenAIRE

    Tjandra Y. Aditama; Sita L. Andarini

    2002-01-01

    Sick building syndrome describes a number of mostly unspesific complaints of some occupants of the building. The exact pathophysiological mechanism remains elusive. It is a multi factorial event which may include physical, chemical, biological as well as psycological factors. In many cases it is due to insufficient maintenance of the HVAC (heating, ventilation, air conditioning) system in the building. Sign and symptoms can be uncomfortable and even disabling, which may include mucus membrane...

  12. Evaluation Tool of Climate Potential for Ventilative Cooling

    DEFF Research Database (Denmark)

    Belleri, Annamaria; Psomas, Theofanis Ch.; Heiselberg, Per Kvols

    2015-01-01

    . Within IEA Annex 62 project, national experts are working on the development of a climate evaluation tool, which aims at assessing the potential of ventilative cooling by taking into account also building envelope thermal properties, internal gains and ventilation needs. The analysis is based on a single......The new initiatives and regulations towards nearly zero energy buildings forces designers to exploit the cooling potential of the climate to reduce the overheating occurrence and to improve thermal comfort indoors. Climate analysis is particularly useful at early design stages to support decision...... making towards cost-effective passive cooling solution e.g. ventilative cooling. As buildings with different use patterns, envelope characteristics and internal loads level do not follow equally the external climate condition, the climate analysis cannot abstract from building characteristics and use...

  13. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, Robb [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    This document addresses adding -or improving - mechanical ventilation systems to existing homes. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including some discussion of relevant codes and standards. Advantages, disadvantages, and approximate costs of various system types are presented along with general guidelines for implementing the systems in homes. CARB intends for this document to be useful to decision makers and contractors implementing ventilation systems in homes. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors. It is the intent of this document to assist contractors in making more informed decisions when selecting systems. Ventilation is an integral part of a high-performance home. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability.

  14. Energy efficient demand controlled ventilation in single family houses

    DEFF Research Database (Denmark)

    Nielsen, Toke Rammer; Drivsholm, Christian

    2010-01-01

    in the Danish building regulations and the low flow rate is based on minimum requirements in indoor air quality standards. Measurements were performed on an existing single family house where the controls were installed on the existing mechanical ventilation system. The results showed that the ventilation can......This paper presents a strategy for a simple demand controlled ventilation system for single family houses where all sensors and controls are located in the air handling unit. The strategy is based on sensing CO2-concentration and moisture content in the outdoor air and exhaust air. The CO2......-concentration is used to ensure adequate ventilation during occupancy and the moisture content is used to ensure adequate removal of moisture produced in the house. The ventilation rate can be switched between two flow rates: a high rate and a low rate. The high flow rate is based on existing requirements...

  15. Livestock-Associated MRSA: The Impact on Humans

    Science.gov (United States)

    Cuny, Christiane; Wieler, Lothar H.; Witte, Wolfgang

    2015-01-01

    During the past 25 years an increase in the prevalence of methicillin-resistant Staphylococcus aureus (HA-MRSA) was recorded worldwide. Additionally, MRSA infections may occur outside and independent of hospitals, caused by community associated MRSA (CA-MRSA). In Germany, we found that at least 10% of these sporadic infections are due to livestock-associated MRSA (LA-MRSA), which is initially associated with livestock. The majority of these MRSA cases are attributed to clonal complex CC398. LA-MRSA CC398 colonizes the animals asymptomatically in about half of conventional pig farms. For about 77%–86% of humans with occupational exposure to pigs, nasal carriage has been reported; it can be lost when exposure is interrupted. Among family members living at the same farms, only 4%–5% are colonized. Spread beyond this group of people is less frequent. The prevalence of LA-MRSA in livestock seems to be influenced by farm size, farming systems, usage of disinfectants, and in-feed zinc. LA-MRSA CC398 is able to cause the same kind of infections in humans as S. aureus and MRSA in general. It can be introduced to hospitals and cause nosocomial infections such as postoperative surgical site infections, ventilator associated pneumonia, septicemia, and infections after joint replacement. For this reason, screening for MRSA colonization at hospital admittance is recommended for farmers and veterinarians with livestock contacts. Intrahospital dissemination, typical for HA-MRSA in the absence of sufficient hygiene, has only rarely been observed for LA-MRSA to date. The proportion of LA-MRSA among all MRSA from nosocomial infections is about 3% across Germany. In geographical areas with a comparatively high density of conventional farms, LA-MRSA accounts for up to 10% of MRSA from septicemia and 15% of MRSA from wound infections. As known from comparative genome analysis, LA-MRSA has evolved from human-adapted methicillin-susceptible S. aureus, and the jump to livestock was

  16. Livestock-Associated MRSA: The Impact on Humans

    Directory of Open Access Journals (Sweden)

    Christiane Cuny

    2015-11-01

    Full Text Available During the past 25 years an increase in the prevalence of methicillin-resistant Staphylococcus aureus (HA-MRSA was recorded worldwide. Additionally, MRSA infections may occur outside and independent of hospitals, caused by community associated MRSA (CA-MRSA. In Germany, we found that at least 10% of these sporadic infections are due to livestock-associated MRSA (LA-MRSA, which is initially associated with livestock. The majority of these MRSA cases are attributed to clonal complex CC398. LA-MRSA CC398 colonizes the animals asymptomatically in about half of conventional pig farms. For about 77%–86% of humans with occupational exposure to pigs, nasal carriage has been reported; it can be lost when exposure is interrupted. Among family members living at the same farms, only 4%–5% are colonized. Spread beyond this group of people is less frequent. The prevalence of LA-MRSA in livestock seems to be influenced by farm size, farming systems, usage of disinfectants, and in-feed zinc. LA-MRSA CC398 is able to cause the same kind of infections in humans as S. aureus and MRSA in general. It can be introduced to hospitals and cause nosocomial infections such as postoperative surgical site infections, ventilator associated pneumonia, septicemia, and infections after joint replacement. For this reason, screening for MRSA colonization at hospital admittance is recommended for farmers and veterinarians with livestock contacts. Intrahospital dissemination, typical for HA-MRSA in the absence of sufficient hygiene, has only rarely been observed for LA-MRSA to date. The proportion of LA-MRSA among all MRSA from nosocomial infections is about 3% across Germany. In geographical areas with a comparatively high density of conventional farms, LA-MRSA accounts for up to 10% of MRSA from septicemia and 15% of MRSA from wound infections. As known from comparative genome analysis, LA-MRSA has evolved from human-adapted methicillin-susceptible S. aureus, and the jump to

  17. What Is a Ventilator?

    Science.gov (United States)

    ... who are on ventilators for shorter periods. The advantage of this tube is that it can be ... Privacy Policy Freedom of Information Act (FOIA) Accessibility Copyright and Usage No FEAR Act Grants and Funding ...

  18. Why We Ventilate

    Energy Technology Data Exchange (ETDEWEB)

    Logue, Jennifer M.; Sherman, Max H.; Price, Phil N.; Singer, Brett C.

    2011-09-01

    It is widely accepted that ventilation is critical for providing good indoor air quality (IAQ) in homes. However, the definition of"good" IAQ, and the most effective, energy efficient methods for delivering it are still matters of research and debate. This paper presents the results of work done at the Lawrence Berkeley National Lab to identify the air pollutants that drive the need for ventilation as part of a larger effort to develop a health-based ventilation standard. First, we present results of a hazard analysis that identified the pollutants that most commonly reach concentrations in homes that exceed health-based standards or guidelines for chronic or acute exposures. Second, we present results of an impact assessment that identified the air pollutants that cause the most harm to the U.S. population from chronic inhalation in residences. Lastly, we describe the implications of our findings for developing effective ventilation standards.

  19. The influence of broiler activity, growth rate, and litter on carbon dioxide balances for the determination of ventilation flow rates in broiler production.

    Science.gov (United States)

    Calvet, S; Estellés, F; Cambra-López, M; Torres, A G; Van den Weghe, H F A

    2011-11-01

    Carbon dioxide balances are useful in determining ventilation rates in livestock buildings. These balances need an accurate estimation of the CO(2) produced by animals and their litter to determine the ventilation flows. To estimate the daily variation in ventilation flow, it is necessary to precisely know the daily variation pattern of CO(2) production, which mainly depends on animal activity. The objective of this study was to explore the applicability of CO(2) balances for determining ventilation flows in broiler buildings. More specifically, this work aimed to quantify the amount of CO(2) produced by the litter, as well as the amount of CO(2) produced by the broilers, as a function of productive parameters, and to analyze the influence of broiler activity on CO(2) emissions. Gas concentrations and ventilation flows were simultaneously measured in 3 trials, with 1 under experimental conditions and the other 2 in a commercial broiler farm. In the experimental assay, broiler activity was also determined. At the end of the experimental trial, on the day after the removal of the broilers, the litter accounted for 20% of the total CO(2) produced, and the broilers produced 3.71 L/h of CO(2) per kg of metabolic weight. On the commercial farm, CO(2) production was the same for the 2 cycles (2.60 L/h per kg of metabolic weight, P > 0.05). However, substantial differences were found between CO(2) and broiler activity patterns after changes in light status. A regression model was used to explain these differences (R(2) = 0.52). Carbon dioxide increased with bird activity, being on average 3.02 L/h per kg of metabolic weight for inactive birds and 4.73 L/h per kg of metabolic weight when bird activity was highest. Overall, CO(2) balances are robust tools for determining the daily average ventilation flows in broiler farms. These balances could also be applied at more frequent intervals, but in this case, particular care is necessary after light status changes because of

  20. Identification and Tracing Groundwater Contamination by Livestock Burial Sites

    Science.gov (United States)

    Ko, K.; Ha, K.; Park, S.; Kim, Y.; Lee, K.

    2011-12-01

    Foot-and-mouth disease (FMD) or hoof-and-mouth disease is a severe plague for animal farming that affects cloven-hoofed animals such as cattle, pigs, sheep, and goats. Since it is highly infectious and can be easily proliferated by infected animals, contaminated equipments, vehicles, clothing, people, and predators. It is widely known that the virus responsible for FMD is a picornavirus, the prototypic member of the genus Aphthovirus. A serious outbreak of foot-and-mouth disease, leading to the stamping out of 3.53 millions of pigs and cattle and the construction of 4,538 burial sites until 15th March, 2011. The build-up of carcass burial should inevitably produce leachate by the decomposition of buried livestock affecting the surround environment such as air, soil, groundwater, and surface water. The most important issues which are currently raised by scientists are groundwater contamination by leachate from the livestock burial sites. This study examined the current status of FMD outbreak occurred in 2010-2011 and the issues of groundwater contamination by leachate from livestock burial sites. The hydrogeochemical, geophysical, and hydrogeological studies were executed to identify and trace groundwater contamination by leachate from livestock burial sites. Generally livestock mortality leachate contains high concentrations of NH3-N, HCO3-, Cl-, SO42-, K+, Na+, P along with relative lesser amounts of iron, calcium, and magnesium. The groundwater chemical data around four burial sites showed high NH3-N, HCO3-, and K+ suggesting the leachate leakage from burial sites. This is also proved by resistivity monitoring survey and tracer tests. The simulation results of leachate dispersion showed the persistent detrimental impacts for groundwater environment for a long time (~50 years). It is need to remove the leachate of burial sites to prevent the dispersion of leachate from livestock burial to groundwater and to monitor the groundwater quality. The most important

  1. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Heiselberg, Per; Nielsen, Peter V.

    2014-01-01

    As a novel air distribution system, diffuse ceiling ventilation combines the suspended acoustic ceiling with ventilation supply. Due to the low-impulse supply from the large ceiling area, the system does not generate draught when supplying cold air. However, heat sources play an important role on...... temperature as well as optimizing the radiant cooling potential by combining with thermal mass is conducted and gives a direction for further investigation....

  2. Measure Guideline: Selecting Ventilation Systems for Existing Homes

    Energy Technology Data Exchange (ETDEWEB)

    Aldrich, R. [Consortium for Advanced Residential Buildings (CARB), Norwalk, CT (United States)

    2014-02-01

    This report, developed by Building America research team CARB, addresses adding or improving mechanical ventilation systems to existing homes. The goal of this report is to assist decision makers and contractors in making informed decisions when selecting ventilation systems for homes. With more air-sealed envelopes, a mechanical means of removing contaminants is critical for indoor environmental quality and building durability. The purpose of ventilation is to remove contaminants from homes, and this report discusses where, when, and how much ventilation is appropriate in a home, including examination of relevant codes and standards. Choosing the "best" system is not always straightforward; selecting a system involves balancing performance, efficiency, cost, required maintenance, and several other factors.

  3. Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    Rudd, Armin [National Renewable Energy Lab. (NREL), Golden, CO (United States); Bergey, Daniel [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2014-02-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow. Cumulative particle counts for six particle sizes, and formaldehyde and other Top 20 VOC concentrations were measured in multiple zones. The testing showed that single-point exhaust ventilation was inferior as a whole-house ventilation strategy. It was inferior because the source of outside air was not direct from outside, the ventilation air was not distributed, and no provision existed for air filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs. System improvement percentages were estimated based on four System Factor Categories: Balance, Distribution, Outside Air Source, and Recirculation Filtration. Recommended System Factors could be applied to reduce ventilation fan airflow rates relative to ASHRAE Standard 62.2 to save energy and reduce moisture control risk in humid climates. HVAC energy savings were predicted to be 8-10%, or $50-$75/year.

  4. A RESEARCH ON VENTILATION EFFICIENCY OF PIPED VENTILATION SYSTEMS IN GEOTHERMALLY HEATED GREENHOUSES

    Directory of Open Access Journals (Sweden)

    İbrahim Örüng

    2016-07-01

    Full Text Available Greenhouse play significant roles in human nutrition. Vegetable and fruit consumption at certain amounts is the basic pre-condition for a well nutrition. It is possible to produce sufficient quantities of fruits and vegetables in places with available climate conditions. However, fruits and vegetables should be grown in special buildings to have a year-long production in places without available climate conditions. These places include under-cover production facilities, greenhouses, low and high tunnel facilities. Environmental conditions are adjusted are adjusted in greenhouses as to provide proper conditions for plant growth and development. Ventilation is used to remove excess heat, moisture and carbon dioxide from the greenhouses. Either natural or mechanical ventilation is used in greenhouses. Mechanical ventilation systems have various advantages over natural systems. However, mostly natural ventilation systems are preferred because of their low installation and operational costs. Both systems operates based on negative pressure. Air exchange rates are usually low in winters and it is quite hard to evenly distribute cold fresh air within the greenhouse. Air inlets are usually placed over side walls and outlets are commonly placed along the ridge. In this study an alternative natural ventilation system was proposed for more efficient ventilation of the greenhouses. In this system, fresh air gets into the greenhouse through ventilation pipes installed beneath the greenhouse floor. The incoming fresh air also heated with geothermal hot water lines, thus direct contact of cold fresh air is prevented. The design and efficiency of piped ventilation systems were provided in this paper.

  5. Conventional mechanical ventilation

    Directory of Open Access Journals (Sweden)

    Tobias Joseph

    2010-01-01

    Full Text Available The provision of mechanical ventilation for the support of infants and children with respiratory failure or insufficiency is one of the most common techniques that are performed in the Pediatric Intensive Care Unit (PICU. Despite its widespread application in the PICUs of the 21st century, before the 1930s, respiratory failure was uniformly fatal due to the lack of equipment and techniques for airway management and ventilatory support. The operating rooms of the 1950s and 1960s provided the arena for the development of the manual skills and the refinement of the equipment needed for airway management, which subsequently led to the more widespread use of endotracheal intubation thereby ushering in the era of positive pressure ventilation. Although there seems to be an ever increasing complexity in the techniques of mechanical ventilation, its successful use in the PICU should be guided by the basic principles of gas exchange and the physiology of respiratory function. With an understanding of these key concepts and the use of basic concepts of mechanical ventilation, this technique can be successfully applied in both the PICU and the operating room. This article reviews the basic physiology of gas exchange, principles of pulmonary physiology, and the concepts of mechanical ventilation to provide an overview of the knowledge required for the provision of conventional mechanical ventilation in various clinical arenas.

  6. Eight challenges in modelling infectious livestock diseases

    Directory of Open Access Journals (Sweden)

    E. Brooks-Pollock

    2015-03-01

    Full Text Available The transmission of infectious diseases of livestock does not differ in principle from disease transmission in any other animals, apart from that the aim of control is ultimately economic, with the influence of social, political and welfare constraints often poorly defined. Modelling of livestock diseases suffers simultaneously from a wealth and a lack of data. On the one hand, the ability to conduct transmission experiments, detailed within-host studies and track individual animals between geocoded locations make livestock diseases a particularly rich potential source of realistic data for illuminating biological mechanisms of transmission and conducting explicit analyses of contact networks. On the other hand, scarcity of funding, as compared to human diseases, often results in incomplete and partial data for many livestock diseases and regions of the world. In this overview of challenges in livestock disease modelling, we highlight eight areas unique to livestock that, if addressed, would mark major progress in the area.

  7. Association of ventilation system type with SBS symptoms in office workers

    Energy Technology Data Exchange (ETDEWEB)

    Seppanen, Olli; Fisk, William J.

    2001-02-07

    This paper provides a review and synthesis of current knowledge about the associations of ventilation system types in office buildings with sick building syndrome symptoms and discusses potential explanations for the associations. Relative to natural ventilation, air conditioning, with or without humidification, was consistently associated with a statistically significant increase in the prevalence of one or more SBS symptoms. Prevalences were typically higher by approximately 30% to 200% in the air conditioned buildings. In two of three assessments from a single study, symptom prevalences were also significantly higher in air conditioned buildings than in buildings with simple mechanical ventilation and no humidification. In approximately half of assessments, SBS symptom prevalences were significantly higher in buildings with simple mechanical ventilation than in buildings with natural ventilation. Insufficient information was available for conclusions about the potential increased risk of SBS symptoms with humidification. The statistically significant associations of mechanical ventilation and air conditioning with SBS symptoms are much more frequent than expected from chance and also not likely to be a consequence of confounding by several potential personal, job, or building related confounders. The reasons for the increases in symptom prevalences with mechanical ventilation and particularly with air conditioning remain unclear. Multiple deficiencies in HVAC system design, construction, operation, or maintenance, including some which cause pollutant emissions from HVAC systems, may contribute to the increases in symptom prevalences.

  8. Monitoring and Simulation of Mechanically Ventilated Underground Car Parks

    OpenAIRE

    Eshack, Adil; D.G., Leo Samuel; S.M., Shiva Nagendra; Maiya, M. Prakash

    2015-01-01

    Rapid motorization in developed and developing countries demands more parking spaces in urban areas. Underground car parking space in multi story buildings offers viable solution. However, lack of natural ventilation accumulates the harmful emissions from cars, operating in underground car parks. Exposure to these hazardous pollutants causes health risk to the users. Therefore, proper mechanical ventilation system should be adopted for the removal of harmful pollutants. This paper discusses t...

  9. Ökompakt 50 - ventilator with heat regenerate

    Directory of Open Access Journals (Sweden)

    Heinz Hölter

    2000-03-01

    Full Text Available In the paper presents ventilator with heat regenerate. The apparaturs are manufactured by f. Hölter, GmbH, and it patent schould. The quality aur in interier is on line relation to different alergical disease (Sick Building Syndrom - SBS.Ventilator with heat regenerate have result in improved of interiors air quality in whick a man dwelled more as 90 % of life.

  10. On analysis of operating efficiency of autonomous ventilation systems

    Directory of Open Access Journals (Sweden)

    Kostuganov Arman

    2017-01-01

    Full Text Available The paper deals with the causes and consequences of malfunctioning of natural and mechanical ventilation systems in civil buildings of Russia. Furthermore it gives their classification and analysis based on the literature review. On the basis of the analysis technical solutions for improving the efficiency of ventilation systems in civil buildings are summarized and the field of their application is specified. Among the offered technical solutions the use of autonomous ventilation systems with heat recovery is highlighted as one of the most promising and understudied. Besides it has a wide range of applications. The paper reviews and analyzes the main Russian and foreign designs of ventilation systems with heat recovery that are mostly used in practice. Three types of such systems: UVRK-50, Prana-150, ТеFо are chosen for consideration. The sequence of field tests of selected autonomous ventilation systems have been carried out in order to determine the actual air exchange and efficiency of heat recovery. The paper presents the processed results of the research on the basis of which advantages and disadvantages of the tested ventilation systems are identified and recommendations for engineering and manufacturing of new design models of autonomous ventilation systems with heat recovery are formulated.

  11. Optimization of Occupancy Based Demand Controlled Ventilation in Residences

    Energy Technology Data Exchange (ETDEWEB)

    Mortensen, Dorthe K.; Walker, Iain S.; Sherman, Max H.

    2011-05-01

    Although it has been used for many years in commercial buildings, the application of demand controlled ventilation in residences is limited. In this study we used occupant exposure to pollutants integrated over time (referred to as 'dose') as the metric to evaluate the effectiveness and air quality implications of demand controlled ventilation in residences. We looked at air quality for two situations. The first is that typically used in ventilation standards: the exposure over a long term. The second is to look at peak exposures that are associated with time variations in ventilation rates and pollutant generation. The pollutant generation had two components: a background rate associated with the building materials and furnishings and a second component related to occupants. The demand controlled ventilation system operated at a low airflow rate when the residence was unoccupied and at a high airflow rate when occupied. We used analytical solutions to the continuity equation to determine the ventilation effectiveness and the long-term chronic dose and peak acute exposure for a representative range of occupancy periods, pollutant generation rates and airflow rates. The results of the study showed that we can optimize the demand controlled airflow rates to reduce the quantity of air used for ventilation without introducing problematic acute conditions.

  12. Passive ventilation systems with heat recovery and night cooling

    DEFF Research Database (Denmark)

    Hviid, Christian Anker; Svendsen, Svend

    2008-01-01

    In building design the requirements for energy consumption for ventilation, heating and cooling and the requirements for increasingly better indoor climate are two opposing factors. This paper presents the schematic layout and simulation results of an innovative multifunc-tional ventilation concept...... with little energy consumption and with satisfying indoor climate. The concept is based on using passive measures like stack and wind driven ventilation, effective night cooling and low pressure loss heat recovery using two fluid coupled water-to-air heat exchangers developed at the Technical University...

  13. Potential of Natural Ventilation in Cold Conditions Countries

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg

    2014-01-01

    The objective of this article is to investigate the energy performance of natural ventilation as a passive cooling method of buildings within houses located in temperate countries using Denmark as a case study. The method consists in running simulations with a thermal-airflow program of a household...... the simulations are validated with measured data, and by applying a new assessment method presented in this article as the cooling rate due to natural ventilation instead of a constant mechanical ventilation rate in the thermal balance within the dwelling, the energy saving is calculated. Results show...

  14. Analysis of the systems of ventilation of residential houses of Ukraine and Estonia

    Science.gov (United States)

    Savchenko, Olena; Zhelykh, Vasyl; Voll, Hendrik

    2017-12-01

    The most common ventilation system in residential buildings in Ukraine is natural ventilation. In recent years, due to increased tightness of structures, an increase in the content of synthetic finishing materials in them, the quality of microclimate parameters deteriorated. One of the measures to improve the parameters of indoor air in residential buildings is the use of mechanical inflow and exhaust ventilation system. In this article the regulatory documents concerning the design of ventilation systems in Ukraine and Estonia and the requirements for air exchange in residential buildings are considered. It is established that the existing normative documents in Ukraine are analogous to European norms, which allow design the system of ventilation of residential buildings according to European standards. However, the basis for the design of ventilation systems in Ukraine is the national standards, in which mechanical ventilation, unfortunately, is provided only for the design of high-rise buildings. To maintain acceptable microclimate parameters in residential buildings, it is advisable for designers to apply the requirements for designing ventilation systems in accordance with European standards.

  15. Relations between Household Livestock Ownership, Livestock Disease, and Young Child Growth123

    OpenAIRE

    Mosites, Emily; Thumbi, Samuel M.; Otiang, Elkanah; McElwain, Terry F.; Njenga, MK; Rabinowitz, Peter M.; Rowhani-Rahbar, Ali; Neuhouser, Marian L.; May, Susanne; Palmer, Guy H.; Walson, Judd L.

    2016-01-01

    Background: In resource-limited settings in which child malnutrition is prevalent, humans live in close proximity to household livestock. However, the relation between household livestock and child nutrition represents a considerable knowledge gap.

  16. Experimental Investigation of Ventilation Efficiency in a Dentistry Surgical Room

    Directory of Open Access Journals (Sweden)

    Oladokun Majeed Olaide

    2016-01-01

    Full Text Available As a response to the need to provide an acceptable thermal comfort and air quality in indoor environments, various ventilation performance indicators were developed over the years. These metrics are mainly geared towards air distribution, heat and pollutant removals. Evidence exists of influencing factors on these indicators as centered on ventilation design and operations. Unlike other indoor environments, health care environment requires better performance of ventilation system to prevent an incidence of nosocomial and other hospital acquired illnesses. This study investigates, using in-situ experiments, the ventilation efficiency in a dentistry surgical room. Thermal and hygric parameters were monitored on the air terminal devices and occupied zone over a period of one week covering both occupied and unoccupied hours. The resulting time-series parameters were used to evaluate the room’s ventilation effectiveness. Also, the obtained parameters were benchmarked against ASHRAE 170 (2013 and MS1525 (2014 requirements for ventilation in health care environment and building energy efficiency respectively. The results show that the mean daily operative conditions failed to satisfy the provisions of both standards. Regarding effectiveness, the findings reveal that the surgical room ventilation is ineffective with ventilation efficiency values ranging between 0 and 0.5 indicating air distribution short-circuiting. These results suggest further investigations, through numerical simulation, on the effect of this short-circuiting on thermal comfort, infection risk assessments and possible design improvements, an endeavour that forms our next line of research inquiries.

  17. 76 FR 43298 - Building Energy Standards Program: Preliminary Determination Regarding Energy Efficiency...

    Science.gov (United States)

    2011-07-20

    .... 40 ap 6. Heating, Includes demand Major + (reduces Ventilating, and Air controlled ventilation energy... Ventilating, and Air demand controlled automatic zone reset Conditioning. ventilation to in multizone include... lighting and power requirements, and the building mechanical equipment requirements. The emphasis of DOE's...

  18. Triggering of the ventilator in patient-ventilator interactions.

    Science.gov (United States)

    Sassoon, Catherine Sh

    2011-01-01

    With current ventilator triggering design, in initiating ventilator breaths patient effort is only a small fraction of the total effort expended to overcome the inspiratory load. Similarly, advances in ventilator pressure or flow delivery and inspiratory flow termination improve patient effort or inspiratory muscle work during mechanical ventilation. Yet refinements in ventilator design do not necessarily allow optimal patient-ventilator interactions, as the clinician is key in managing patient factors and selecting appropriate ventilator factors to maintain patient-ventilator synchrony. In patient-ventilator interactions, unmatched patient flow demand by ventilator flow delivery results in flow asynchrony, whereas mismatches between mechanical inspiratory time (mechanical T(I)) and neural T(I) produce timing asynchrony. Wasted efforts are an example of timing asynchrony. In the triggering phase, trigger thresholds that are set too high or the type of triggering methods induces wasted efforts. Wasted efforts can be aggravated by respiratory muscle weakness or other conditions that reduce respiratory drive. In the post-triggering phase, ventilator factors play an important role in patient-ventilator interaction; this role includes the assistance level, set inspiratory flow rate, T(I), pressurization rate, and cycling-off threshold, and to some extent, applied PEEP. This paper proposes an algorithm that clinicians can use to adjust ventilator settings with the goal to eliminate or reduce patients' wasted efforts.

  19. Mapping the global distribution of livestock.

    Directory of Open Access Journals (Sweden)

    Timothy P Robinson

    Full Text Available Livestock contributes directly to the livelihoods and food security of almost a billion people and affects the diet and health of many more. With estimated standing populations of 1.43 billion cattle, 1.87 billion sheep and goats, 0.98 billion pigs, and 19.60 billion chickens, reliable and accessible information on the distribution and abundance of livestock is needed for a many reasons. These include analyses of the social and economic aspects of the livestock sector; the environmental impacts of livestock such as the production and management of waste, greenhouse gas emissions and livestock-related land-use change; and large-scale public health and epidemiological investigations. The Gridded Livestock of the World (GLW database, produced in 2007, provided modelled livestock densities of the world, adjusted to match official (FAOSTAT national estimates for the reference year 2005, at a spatial resolution of 3 minutes of arc (about 5×5 km at the equator. Recent methodological improvements have significantly enhanced these distributions: more up-to date and detailed sub-national livestock statistics have been collected; a new, higher resolution set of predictor variables is used; and the analytical procedure has been revised and extended to include a more systematic assessment of model accuracy and the representation of uncertainties associated with the predictions. This paper describes the current approach in detail and presents new global distribution maps at 1 km resolution for cattle, pigs and chickens, and a partial distribution map for ducks. These digital layers are made publically available via the Livestock Geo-Wiki (http://www.livestock.geo-wiki.org, as will be the maps of other livestock types as they are produced.

  20. Effects of wolf mortality on livestock depredations.

    Directory of Open Access Journals (Sweden)

    Robert B Wielgus

    Full Text Available Predator control and sport hunting are often used to reduce predator populations and livestock depredations, but the efficacy of lethal control has rarely been tested. We assessed the effects of wolf mortality on reducing livestock depredations in Idaho, Montana and Wyoming from 1987-2012 using a 25 year time series. The number of livestock depredated, livestock populations, wolf population estimates, number of breeding pairs, and wolves killed were calculated for the wolf-occupied area of each state for each year. The data were then analyzed using a negative binomial generalized linear model to test for the expected negative relationship between the number of livestock depredated in the current year and the number of wolves controlled the previous year. We found that the number of livestock depredated was positively associated with the number of livestock and the number of breeding pairs. However, we also found that the number of livestock depredated the following year was positively, not negatively, associated with the number of wolves killed the previous year. The odds of livestock depredations increased 4% for sheep and 5-6% for cattle with increased wolf control--up until wolf mortality exceeded the mean intrinsic growth rate of wolves at 25%. Possible reasons for the increased livestock depredations at ≤25% mortality may be compensatory increased breeding pairs and numbers of wolves following increased mortality. After mortality exceeded 25%, the total number of breeding pairs, wolves, and livestock depredations declined. However, mortality rates exceeding 25% are unsustainable over the long term. Lethal control of individual depredating wolves may sometimes necessary to stop depredations in the near-term, but we recommend that non-lethal alternatives also be considered.

  1. TECHNOLOGIES TO REDUCE EMISSIONS OF NOXIOUS GASES RESULTING FROM LIVESTOCK FARMING

    Directory of Open Access Journals (Sweden)

    Anna Smurzyńska

    2016-05-01

    Full Text Available During the animal production, which is increasingly expanding, it comes to harmful gas emissions. These emissions relate to both greenhouse and odorous gases emissions. The resulting volatile compounds also contribute to the formation of acid rain, eutrophication of water aquens and soils, corrosion in livestock buildings and damage of the ozone layer. Considering the existing problem, solutions neutralizing the impact of animal production on the environment, are being looked for. Moreover, numerous activities in the way of nutritional and technological solutions are undertaken. Nutritional techniques are based on diet modification and require continuous monitoring of livestock animals. On the other hand, technological solutions are taking action to reduce emissions of gases from livestock buildings and slurry management. The proposed ways of disposing slurry result in different effects in terms of reduction of dangerous gases. They require the implementation of additional actions leading, among other things, to the proper animal waste disposal.

  2. Ventilation rates in recently constructed U.S. school classrooms.

    Science.gov (United States)

    Batterman, S; Su, F-C; Wald, A; Watkins, F; Godwin, C; Thun, G

    2017-09-01

    Low ventilation rates (VRs) in schools have been associated with absenteeism, poorer academic performance, and teacher dissatisfaction. We measured VRs in 37 recently constructed or renovated and mechanically ventilated U.S. schools, including LEED and EnergyStar-certified buildings, using CO2 and the steady-state, build-up, decay, and transient mass balance methods. The transient mass balance method better matched conditions (specifically, changes in occupancy) and minimized biases seen in the other methods. During the school day, air change rates (ACRs) averaged 2.0±1.3 hour(-1) , and only 22% of classrooms met recommended minimum ventilation rates. HVAC systems were shut off at the school day close, and ACRs dropped to 0.21±0.19 hour(-1) . VRs did not differ by building type, although cost-cutting and comfort measures resulted in low VRs and potentially impaired IAQ. VRs were lower in schools that used unit ventilators or radiant heating, in smaller schools and in larger classrooms. The steady-state, build-up, and decay methods had significant limitations and biases, showing the need to confirm that these methods are appropriate. Findings highlight the need to increase VRs and to ensure that energy saving and comfort measures do not compromise ventilation and IAQ. © 2017 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Mechanical ventilation strategies.

    Science.gov (United States)

    Keszler, Martin

    2017-08-01

    Although only a small proportion of full term and late preterm infants require invasive respiratory support, they are not immune from ventilator-associated lung injury. The process of lung damage from mechanical ventilation is multifactorial and cannot be linked to any single variable. Atelectrauma and volutrauma have been identified as the most important and potentially preventable elements of lung injury. Respiratory support strategies for full term and late preterm infants have not been as thoroughly studied as those for preterm infants; consequently, a strong evidence base on which to make recommendations is lacking. The choice of modalities of support and ventilation strategies should be guided by the specific underlying pathophysiologic considerations and the ventilatory approach must be individualized for each patient based on the predominant pathophysiology at the time. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Chapter 2: Livestock and Grazed Lands Emissions

    Science.gov (United States)

    A total of 342 MMT CO2 eq. of greenhouse gasses (GHGs) were emitted from livestock, managed livestock waste, and grazed land in 2013. This represents about 66% of total emissions from the agricultural sector, which totaled 516 MMT CO2 eq. Compared to the base line year (1990), emissions from livesto...

  5. Precision Livestock Farming: het dier centraal

    NARCIS (Netherlands)

    Lokhorst, C.

    2010-01-01

    Dit essay gaat over het concept Precision Livestock Farming (PLF). Voor de melkveehouderij is dit beschreven in het Wageningen UR Livestock rapport 358 (Kees Lokhorst, Bert Ipema, Edwin Bleumer, 2010. Haalbaarheid precisielandbouw voor de Melkveehouderij, ISSN 1570 – 8616, 21pp). Het PLF-concept is

  6. Eight challenges in modelling infectious livestock diseases

    NARCIS (Netherlands)

    Brooks-Pollock, E.; Jong, de M.; Keeling, M.J.; Klinkenberg, D.; Wood, J.L.N.

    2015-01-01

    The transmission of infectious diseases of livestock does not differ in principle from disease transmission in any other animals, apart from that the aim of control is ultimately economic, with the influence of social, political and welfare constraints often poorly defined. Modelling of livestock

  7. Livestock Husbandry and Snow Leopard Conservation

    NARCIS (Netherlands)

    Mohammad, Ghulam; Mostafawi, Sayed Naqibullah; Dadul, Jigmet; Rosen, Tatjana; Mishra, Charudutt; Bhatnagar, Yash Veer; Trivedi, Pranav; Timbadia, Radhika; Bijoor, Ajay; Murali, Ranjini; Sonam, Karma; Thinley, Tanzin; Namgail, Tsewang; Prins, Herbert H.T.; Nawaz, Muhammad Ali; Ud Din, Jaffar; Buzdar, Hafeez

    2016-01-01

    Livestock depredation is a key source of snow leopard mortality across much of the species' range. Snow leopards break into livestock corrals, killing many domestic animals and thereby inflicting substantial economic damage. Locals may retaliate by killing the cat and selling its parts.

  8. Women, Livestock Markets and Income Management

    International Development Research Centre (IDRC) Digital Library (Canada)

    decisions about spending of their earnings. Even when women have control over income, commercialisation of production can erode income management. This is an increasing concern, with rising demand for livestock and livestock products, particularly among urban consumers, changing markets and marketing systems.

  9. Livestock: An alternative mosquito control measure | Yakubu ...

    African Journals Online (AJOL)

    A survey was conducted to investigate the indigenous methods or measures adopted by urban livestock owners in the control of mosquito in Sokoto metropolis. Fifty (50) respondents who were engaged in urban livestock production were conveniently sampled, In addition, five (5) locations (Sidi farm, Kara market, Sokoto ...

  10. Livestock farming with care : summaries of essays

    NARCIS (Netherlands)

    Eijsackers, H.J.P.; Scholten, M.C.T.

    2011-01-01

    Wageningen UR is the country’s major research organisation in the field of livestock farming, providing the knowledge base for innovative livestock farming in our country and beyond and, as such, keen to play a role in the above mentioned debate. To this end an interdisciplinary task force was

  11. 50 CFR 35.9 - Livestock grazing.

    Science.gov (United States)

    2010-10-01

    ... 50 Wildlife and Fisheries 6 2010-10-01 2010-10-01 false Livestock grazing. 35.9 Section 35.9 Wildlife and Fisheries UNITED STATES FISH AND WILDLIFE SERVICE, DEPARTMENT OF THE INTERIOR (CONTINUED) THE..., reconstruction or relocation of only those livestock management improvements and structures which existed within...

  12. Airborne microorganisms and dust from livestock houses

    NARCIS (Netherlands)

    Zhao, Y.; Aarnink, A.J.A.; Jong, de M.C.M.; Groot Koerkamp, P.W.G.

    2011-01-01

    The objective of this study was to evaluate the efficiencies and suitability of samplers for airborne microorganisms and dust, which could be used in practical livestock houses. Two studies were performed: 1) Testing impaction and cyclone pre-separators for dust sampling in livestock houses; 2)

  13. Assessment of Indigenous Knowledge Application among Livestock ...

    African Journals Online (AJOL)

    Assessment of Indigenous Knowledge Application among Livestock Farmers in Southern Ijaw Local Government Area of Bayelsa State. ... It is therefore suggested that farmers' level of education should be improved while efforts should be made to blend the traditional and conventional (improved) technologies livestock ...

  14. Gender and Livestock: Issues, Challenges and Opportunities

    International Development Research Centre (IDRC) Digital Library (Canada)

    Securing current and future assets. • Sustaining and improving the productivity of agricultural systems in ... However, studies have shown that women do sometimes manage income from the sale of livestock products even when they do not own the livestock. In Tanzania, for example, women manage 49% of income from the.

  15. Technology Solutions Case Study: Ventilation System Effectiveness and Tested Indoor Air Quality Impacts

    Energy Technology Data Exchange (ETDEWEB)

    A. Rudd and D. Bergey

    2015-08-01

    Ventilation system effectiveness testing was conducted at two unoccupied, single-family, detached lab homes at the University of Texas - Tyler. Five ventilation system tests were conducted with various whole-building ventilation systems. Multizone fan pressurization testing characterized building and zone enclosure leakage. PFT testing showed multizone air change rates and interzonal airflow filtration. Indoor air recirculation by a central air distribution system can help improve the exhaust ventilation system by way of air mixing and filtration. In contrast, the supply and balanced ventilation systems showed that there is a significant benefit to drawing outside air from a known outside location, and filtering and distributing that air. Compared to the Exhaust systems, the CFIS and ERV systems showed better ventilation air distribution and lower concentrations of particulates, formaldehyde and other VOCs.

  16. Solar assisted ventilation tower, Frederiksberg[Denmark]; Ventilationsanlaeggenes betydning for ejendommens varmeforbrug. Delrapport 1

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2002-04-01

    The project has demonstrated a building integrated ventilation system with the ducts system installed outside the facade. The air ducts are installed in a solar tower parallel to the staircases in the courtyard. The towers utilise the solar energy for preheating the ventilation air. An air handling unit with counterflow heat exchanger is installed in the roof space. The system is designed for old building block, which are going to be renovated with mechanical ventilation. The system saves room space for the installations of the ventilation ducts. The monitoring of the system performance shows energy saving of 40% caused by new windows, individual heat meters and ventilation with heat recovery and solar tower. The system efficiency of the solar tower is high compared with other traditional solar wall constructions. The ventilation system is designed with a very low electricity consumption of the fans. The monitored electricity consumption is 22 W per dwellings. (au)

  17. Meeting Residential Ventilation Standards Through Dynamic Control of Ventilation Systems

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, Max H.; Walker, Iain S.

    2011-04-01

    Existing ventilation standards, including American Society of Heating, Refrigerating, and Air-conditioning Engineers (ASHRAE) Standard 62.2, specify continuous operation of a defined mechanical ventilation system to provide minimum ventilation, with time-based intermittent operation as an option. This requirement ignores several factors and concerns including: other equipment such as household exhaust fans that might incidentally provide ventilation, negative impacts of ventilation when outdoor pollutant levels are high, the importance of minimizing energy use particularly during times of peak electricity demand, and how the energy used to condition air as part of ventilation system operation changes with outdoor conditions. Dynamic control of ventilation systems can provide ventilation equivalent to or better than what is required by standards while minimizing energy costs and can also add value by shifting load during peak times and reducing intake of outdoor air contaminants. This article describes the logic that enables dynamic control of whole-house ventilation systems to meet the intent of ventilation standards and demonstrates the dynamic ventilation system control concept through simulations and field tests of the Residential Integrated Ventilation-Energy Controller (RIVEC).

  18. Piroplasmids of livestock in Tunisia.

    Science.gov (United States)

    Darghouth, M A

    2004-01-01

    Several species of piroplasms of livestock are present in Tunisia; some of them are of high veterinary importance. This paper reviews the species already reported in Tunisia on the basis of clinical observations, parasitological routine diagnostic and serological surveys, as well as those considered as potentially present according to epidemiological argumentations. The genus Theileria includes four species reported in Tunisia: T. annulata, T. buffeli, T. ovis, and T. equi. The ovine malignant theileriosis agent, T. lestoquardi, appears to be absent in Tunisia. Five species belonging to the genus Babesia were reported in the country, namely B. hovis, B. bigemina, B. divergens, B. caballi, and B. ovis. Furthermore, two more species, B. major and B. motasi, are potentially present in zones where their vectors of the genus Haemaphysalis occur.

  19. Natural ventilation: it's as easy as opening the windows, or is it

    Energy Technology Data Exchange (ETDEWEB)

    Siebein, G.W.

    1984-10-01

    The research consisted of an evaluation of the existing technologies available for passive cooling with an emphasis on strategies related to the use of natural ventilation. A preliminary data base for the study was established by three major efforts: 1. An extensive literature search of the architectural press was undertaken to ascertain the degree to which passive cooling strategies in general and natural ventilation in particular are designed into buildings at the present time. 2. An investigation of existing building stock profiles was undertaken to identify the existing and potential obstacles or advantages to the implementation of natural ventilation as a passive cooling strategy. The EIA Nonresidential Buildings Energy Consumption Survey and two previous PNL studies were reviewed. 3. Components 1 and 2 were followed up with telephone interviews and site visits with the architects, building owners and operators of selected buildings from 1 and 2 above to gain more specific insights into the problems and pleasures typically associated with natural ventilation.

  20. Evaluation of Discharge Coefficients for Window Openings in Wind Driven Natural Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Sandberg, Mats

    2006-01-01

    This paper describes the classical approach for calculation of wind driven airflow through large openings in buildings and discusses the fulfilment of the limiting assumptions. It is demonstrated that the limiting assumptions are not fulfilled for large openings in buildings for cross ventilation...... cannot be regarded as a constant and it is very difficult to estimate correct values resulting in less accuracy of prediction of natural ventilation.......This paper describes the classical approach for calculation of wind driven airflow through large openings in buildings and discusses the fulfilment of the limiting assumptions. It is demonstrated that the limiting assumptions are not fulfilled for large openings in buildings for cross ventilation......, and therefore, the classical approach is not appropriate for prediction of airflow through large openings in buildings in the cross ventilation case. Using the approach for real openings and estimating the discharge coefficient for window openings has also not been very successful. The discharge coefficient...

  1. Integrated crop-livestock systems and cover crop grazing in the Northern Great Plains

    Science.gov (United States)

    Integrating crops and livestock has been identified as an approach to sustainably intensify agricultural systems, increasing production while reducing the need for external inputs, building soil health, and increasing economic returns. Cover crops and grazing these cover crops are a natural fit with...

  2. Single-sided Natural Ventilation Driven by a Combination of Wind Pressure and Temperature Difference

    DEFF Research Database (Denmark)

    Larsen, Tine Steen; Heiselberg, Per

    2007-01-01

    . In both situations the aim is to obtain a good indoor environment but to control the amount of air, some basic knowledge of the flow through an opening is necessary. The amount of air going through the window opening in single-sided ventilation will depend on the wind speed near the building......, which make the prediction difficult. From earlier work, a few design expressions for single-sided ventilation already exist, but none of these include the wind direction, which here is an important parameter. Therefore several wind tunnel experiments are made in this work to find a new design expression......Natural ventilation is a commonly used principle when ventilation systems for buildings are designed. The ventilation can either be obtained by automatically controlled openings in the building envelope, or it can just be the simple action of opening a door or a window to let the fresh air in...

  3. Ventilation Criteria for Aeromedical Evacuation.

    Science.gov (United States)

    1986-09-01

    number) FIELD GROUP i SUB-GROUP Aeromedical evacuation; Ventilatory requirements; 06 11 06 12 iAir evacuation; and Mechanical ventilation . 19...ABSTRACT (Continue on reverse if necessary and identify by block number) -., fr evacLation of patients requiring mechanical ventilation exposes these...reasonably stable from a medical standpoint; none required mechanical ventilation . Unfortunately, we find no .- , studies that describe the

  4. The amazing Minivent ventilator

    African Journals Online (AJOL)

    TYYCVNCi2nM. Acknowledgements – The authors wish to thank Dr Christine Ball for the photograph of Dr Cohen and Dr Cohen for providing them with the last Minivent ventilator in his possession. It is still functioning and may be seen in the Nagin ...

  5. Measure Guideline: Ventilation Cooling

    Energy Technology Data Exchange (ETDEWEB)

    Springer, D.; Dakin, B.; German, A.

    2012-04-01

    The purpose of this measure guideline on ventilation cooling is to provide information on a cost-effective solution for reducing cooling system energy and demand in homes located in hot-dry and cold-dry climates. This guideline provides a prescriptive approach that outlines qualification criteria, selection considerations, and design and installation procedures.

  6. Understanding mechanical ventilators.

    Science.gov (United States)

    Chatburn, Robert L

    2010-12-01

    The respiratory care academic community has not yet adopted a standardized system for classifying and describing modes of ventilation. As a result, there is enough confusion that patient care, clinician education and even ventilator sales are all put at risk. This article summarizes a ventilator mode taxonomy that has been extensively published over the last 15 years. Specifically, the classification system has three components: a description of the control variables within breath; a description of the sequence of mandatory and spontaneous breaths; and a specification for the targeting scheme. This three-level specification provides scalability of detail to make the mode description appropriate for the particular need. At the bedside, we need only refer to a mode briefly using the first or perhaps first and second components. To distinguish between similar modes and brand names, we would need to include all components. This taxonomy uses the equation of motion for the respiratory system as the underlying theoretical framework. All terms relevant to describing modes of mechanical ventilation are defined in an extensive appendix.

  7. Mechanical ventilation of mice

    NARCIS (Netherlands)

    Schwarte, L. A.; Zuurbier, C. J.; Ince, C.

    2000-01-01

    Due to growing interest in murine functional genomics research, there is an increasing need for physiological stable in vivo murine models. Of special importance is support and control of ventilation by artificial respiration, which is difficult to execute as a consequence of the small size of the

  8. Elforbrug til mekanisk ventilation

    DEFF Research Database (Denmark)

    Olufsen, P.

    I Energi 2000 er ventilationsområdet udpeget som et af de områder, hvor der bør tages initiativ til at fremme elbesparelser. I rapporten beskrives og analyseres målinger af elforbruget til ventilation i 12 bygninger, der alle anvendes til administration eller lignende formål. På grundlag af...

  9. Increasing natural ventilation using solar chimney

    Directory of Open Access Journals (Sweden)

    Nakielska Magdalena

    2017-01-01

    Full Text Available At a time when much attention is paid to the problem of energy saving is looking for new technical solutions, among others in the construction industry. At present, searching new solutions is a worldwide trend in creating buildings. Those solutions enable a comfortable use of building structures in harmony with natural environment and ensure reducing energy consumption. Solar chimneys, which facilitate the gravity ventilation by using solar energy, may be a solution to the problem. In hot climates solar chimney has been applied in the process of passive cooling of a building. In temperate zones and cold is used to assist natural ventilation. The problem of the solar chimney is not popular in Poland. Construction in Bydgoszcz two research positions, enabled the analysis of the impact of solar chimneys on the thermal comfort of rooms. This article presents experimental studies on solar chimney located in Poland. The analysis of the flow of air in the room during the day have been measured using two testmodels situated on the 3.1 building of UTP University of Science and Technology at 7 Kaliska street in Bydgoszcz.

  10. Formaldehyde as a basis for residential ventilation rates

    Energy Technology Data Exchange (ETDEWEB)

    Sherman, M.H.; Hodgson, A.T.

    2002-04-28

    Traditionally, houses in the U.S. have been ventilated by passive infiltration in combination with active window opening. However in recent years, the construction quality of residential building envelopes has been improved to reduce infiltration, and the use of windows for ventilation also may have decreased due to a number of factors. Thus, there has been increased interest in engineered ventilation systems for residences. The amount of ventilation provided by an engineered system should be set to protect occupants from unhealthy or objectionable exposures to indoor pollutants, while minimizing energy costs for conditioning incoming air. Determining the correct ventilation rate is a complex task, as there are numerous pollutants of potential concern, each having poorly characterized emission rates, and poorly defined acceptable levels of exposure. One ubiquitous pollutant in residences is formaldehyde. The sources of formaldehyde in new houses are reasonably understood, and there is a large body of literature on human health effects. This report examines the use of formaldehyde as a means of determining ventilation rates and uses existing data on emission rates of formaldehyde in new houses to derive recommended levels. Based on current, widely accepted concentration guidelines for formaldehyde, the minimum and guideline ventilation rates for most new houses are 0.28 and 0.5 air changes per hour, respectively.

  11. Patient-ventilator dyssynchrony during assisted invasive mechanical ventilation.

    Science.gov (United States)

    Murias, G; Villagra, A; Blanch, L

    2013-04-01

    Patient-ventilator dyssynchrony is common during mechanical ventilation. Dyssynchrony decreases comfort, prolongs mechanical ventilation and intensive care unit stays, and might lead to worse outcome. Dyssynchrony can occur during the triggering of the ventilator, the inspiration period after triggering, the transition from inspiration to expiration, and the expiratory phase. The most common dyssynchronies are delayed triggering, autotriggering, ineffective inspiratory efforts (which can occur at any point in the respiratory cycle), mismatch between the patient's and ventilator's inspiratory times, and double triggering. At present, the detection of dyssynchronies usually depends on healthcare staff observing ventilator waveforms; however, performance is suboptimal and many events go undetected. To date, technological complexity has made it impossible to evaluate patient-ventilator synchrony throughout the course of mechanical ventilation. Studies have shown that a high index of dyssynchrony may increase the duration of mechanical ventilation. Better training, better ventilatory modes, and/or computerized systems that permit better synchronization of patients' demands and ventilator outputs are necessary to improve patient-ventilator synchrony.

  12. Performance of ductless personalized ventilation in conjunction with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Melikov, Arsen Krikor; Vesely, Michal

    2014-01-01

    The performance of ductless personalized ventilation (DPV) in conjunction with displacement ventilation was studied and compared with displacement ventilation alone and mixing ventilation. Thirty subjects were exposed in a climate chamber to environmental conditions representing three levels...... perception of the environment. The subjects could control the position of the DPV supply diffuser and the personalized air flow (air velocity). The use of DPV improved perceived air quality and thermal comfort compared to displacement ventilation alone. At 26 °C and 29 °C the percentage dissatisfied with air...... movement decreased with DPV compared to corresponding conditions with displacement ventilation alone and reached the same level as mixing or displacement ventilation at 23 °C. Subjects were able to control the volume and speed of the personalized air flow in order to avoid eye irritation. However...

  13. Human response to ductless personalized ventilation coupled with displacement ventilation

    DEFF Research Database (Denmark)

    Dalewski, Mariusz; Veselý, Michal; Melikov, Arsen K.

    2012-01-01

    A human subject experiment was carried out to investigate the extent to which ductless personalized ventilation (DPV) in conjunction with displacement ventilation can improve perceived air quality (PAQ) and thermal comfort at elevated room air temperature in comparison with displacement ventilation...... alone. The experimental conditions comprised displacement ventilation alone (room air temperature of 23 °C, 26 °C, 29 °C) and DPV with displacement ventilation (26 °C, 29 °C), both operating at supply air temperatures 3, 5 or 6K lower than room air temperature, as well as mixing ventilation (23 °C, 3 K......). During one hour exposure participants answered questionnaires regarding PAQ and thermal comfort. PAQ was significantly better with DPV than without DPV at the same background conditions. Thermal comfort improved when DPV was used. Combining DPV with displacement ventilation showed the potential...

  14. Livestock production: recent trends, future prospects.

    Science.gov (United States)

    Thornton, Philip K

    2010-09-27

    The livestock sector globally is highly dynamic. In developing countries, it is evolving in response to rapidly increasing demand for livestock products. In developed countries, demand for livestock products is stagnating, while many production systems are increasing their efficiency and environmental sustainability. Historical changes in the demand for livestock products have been largely driven by human population growth, income growth and urbanization and the production response in different livestock systems has been associated with science and technology as well as increases in animal numbers. In the future, production will increasingly be affected by competition for natural resources, particularly land and water, competition between food and feed and by the need to operate in a carbon-constrained economy. Developments in breeding, nutrition and animal health will continue to contribute to increasing potential production and further efficiency and genetic gains. Livestock production is likely to be increasingly affected by carbon constraints and environmental and animal welfare legislation. Demand for livestock products in the future could be heavily moderated by socio-economic factors such as human health concerns and changing socio-cultural values. There is considerable uncertainty as to how these factors will play out in different regions of the world in the coming decades.

  15. Relations between Household Livestock Ownership, Livestock Disease, and Young Child Growth.

    Science.gov (United States)

    Mosites, Emily; Thumbi, Samuel M; Otiang, Elkanah; McElwain, Terry F; Njenga, M K; Rabinowitz, Peter M; Rowhani-Rahbar, Ali; Neuhouser, Marian L; May, Susanne; Palmer, Guy H; Walson, Judd L

    2016-05-01

    In resource-limited settings in which child malnutrition is prevalent, humans live in close proximity to household livestock. However, the relation between household livestock and child nutrition represents a considerable knowledge gap. We assessed whether household livestock ownership or livestock disease episodes were associated with growth in young children in western Kenya. We incorporated monthly anthropometric measurements for children livestock ownership was related to baseline child height for age or prospective growth rate. We also evaluated whether livestock disease episodes were associated with child growth rate over 11 mo of follow-up. We collected data on 925 children over the course of follow-up. Greater household livestock ownership at baseline was not related to baseline child height-for-age z score (adjusted β: 0.01 SD; 95% CI: -0.02, 0.04 SD) or child growth rate (adjusted β: 0.02 cm/y; 95% CI: -0.03, 0.07 cm/y). Livestock disease episodes were not significantly associated with child growth across the entire cohort (adjusted β: -0.007 cm/mo; 95% CI: -0.02, 0.006 cm/mo). However, children in households with livestock digestive disease between June and November gained less height than did children in households that did not report livestock disease (β: -0.063 cm/mo; 95% CI: -0.112, -0.016 cm/mo). Children livestock digestive disease gained less weight than did those who did not report disease (β: -0.033 kg/mo; 95% CI: -0.063, -0.003 kg/mo). In this cohort of young children in western Kenya, we did not find an association between ownership of livestock and child growth status. However, disease episodes in household livestock may be related to a lower child growth rate in some groups. © 2016 American Society for Nutrition.

  16. Relations between Household Livestock Ownership, Livestock Disease, and Young Child Growth123

    Science.gov (United States)

    Mosites, Emily; Thumbi, Samuel M; Otiang, Elkanah; McElwain, Terry F; Njenga, MK; Rabinowitz, Peter M; Rowhani-Rahbar, Ali; Neuhouser, Marian L; May, Susanne; Palmer, Guy H; Walson, Judd L

    2016-01-01

    Background: In resource-limited settings in which child malnutrition is prevalent, humans live in close proximity to household livestock. However, the relation between household livestock and child nutrition represents a considerable knowledge gap. Objective: We assessed whether household livestock ownership or livestock disease episodes were associated with growth in young children in western Kenya. Methods: We incorporated monthly anthropometric measurements for children livestock ownership was related to baseline child height for age or prospective growth rate. We also evaluated whether livestock disease episodes were associated with child growth rate over 11 mo of follow-up. Results: We collected data on 925 children over the course of follow-up. Greater household livestock ownership at baseline was not related to baseline child height-for-age z score (adjusted β: 0.01 SD; 95% CI: −0.02, 0.04 SD) or child growth rate (adjusted β: 0.02 cm/y; 95% CI: −0.03, 0.07 cm/y). Livestock disease episodes were not significantly associated with child growth across the entire cohort (adjusted β: −0.007 cm/mo; 95% CI: −0.02, 0.006 cm/mo). However, children in households with livestock digestive disease between June and November gained less height than did children in households that did not report livestock disease (β: −0.063 cm/mo; 95% CI: −0.112, −0.016 cm/mo). Children livestock digestive disease gained less weight than did those who did not report disease (β: −0.033 kg/mo; 95% CI: −0.063, −0.003 kg/mo). Conclusion: In this cohort of young children in western Kenya, we did not find an association between ownership of livestock and child growth status. However, disease episodes in household livestock may be related to a lower child growth rate in some groups. PMID:27075911

  17. Sealed Crawl Spaces with Integrated Whole-House Ventilation in a Cold Climate

    Energy Technology Data Exchange (ETDEWEB)

    Zoeller, William [National Renewable Energy Lab. (NREL), Golden, CO (United States); Williamson, James [National Renewable Energy Lab. (NREL), Golden, CO (United States); Puttafunta, Srikanth [National Renewable Energy Lab. (NREL), Golden, CO (United States)

    2015-07-30

    One method of code-compliance for crawlspaces is to seal and insulate the crawlspace, rather than venting to the outdoors. However, codes require mechanical ventilation; either via conditioned supply air from the HVAC system, or a continuous exhaust ventilation strategy. As the CARB's building partner, Ithaca Neighborhood Housing Services, intended to use the unvented crawlspace in a recent

  18. Analysis of Natural Ventilation in a Passive House Located in Cold Conditions

    DEFF Research Database (Denmark)

    Oropeza-Perez, Ivan; Østergaard, Poul Alberg; Remmen, Arne

    2013-01-01

    This article shows the potential of using natural ventilation as a passive method of cooling buildings that are located in cold climate countries using Denmark as a case study. The energy saving potential of natural ventilation is found by performing thermal simulations of a household located in ...

  19. Ventrain: an ejector ventilator for emergency use.

    Science.gov (United States)

    Hamaekers, A E W; Borg, P A J; Enk, D

    2012-06-01

    A small, flow-regulated, manually operated ventilator designed for ventilation through a narrow-bore transtracheal catheter (TTC) has become available (Ventrain, Dolphys Medical BV, Eindhoven, The Netherlands). It is driven by a predetermined flow of oxygen from a high-pressure source and facilitates expiration by suction. The aim of this bench study was to test the efficacy of this new ventilator. The driving pressure, generated insufflation, and suction pressures and also the suction capacity of the Ventrain were measured at different oxygen flows. The minute volume achieved in an artificial lung through a TTC with an inner diameter (ID) of 2 mm was determined at different settings. Oxygen flows of 6-15 litre min(-1) resulted in driving pressures of 0.5-2.3 bar. Insufflation pressures, measured proximal to the TTC, ranged from 23 to 138 cm H(2)O. The maximal subatmospheric pressure build-up was -217 cm H(2)O. The suction capacity increased to a maximum of 12.4 litre min(-1) at an oxygen flow of 15 litre min(-1). At this flow, the achievable minute volume through the TTC ranged from 5.9 to 7.1 litres depending on the compliance of the artificial lung. The results of this bench study suggest that the Ventrain is capable of achieving a normal minute volume for an average adult through a 2 mm ID TTC. Further in vivo studies are needed to determine the value of the Ventrain as a portable emergency ventilator in a 'cannot intubate, cannot ventilate' situation.

  20. Time Delay for Aerial Ammonia Concentration Measurements in Livestock Buildings

    OpenAIRE

    Rom; Zhang

    2010-01-01

    Correct measurements of ammonia concentration in air still present considerable challenges. The high water solubility and polarity can cause it to adsorb on surfaces in the entire sampling system, including sampling lines, filters, valves, pumps and instruments, causing substantial measuring errors and time delays. To estimate time delay characteristics of a Photo Acoustic Multi Gas Monitor 1312 and a Multi Point Sampler continuous measurement of aerial ammonia concentrations at different lev...

  1. Time delay for aerial ammonia concentration measurements in livestock buildings.

    Science.gov (United States)

    Rom, Hans Benny; Zhang, Guo-Qiang

    2010-01-01

    Correct measurements of ammonia concentration in air still present considerable challenges. The high water solubility and polarity can cause it to adsorb on surfaces in the entire sampling system, including sampling lines, filters, valves, pumps and instruments, causing substantial measuring errors and time delays. To estimate time delay characteristics of a Photo Acoustic Multi Gas Monitor 1312 and a Multi Point Sampler continuous measurement of aerial ammonia concentrations at different levels was performed. In order to obtain reproducible data, a wind tunnel was used to generate selected concentrations inside and a background concentration representing the air inlet of the tunnel. Four different concentration levels (0.8 ppm, 6.2 ppm, 9.7 ppm and 13.7 ppm) were used in the experiments, with an additional outdoor concentration level as background. The results indicated a substantial time delay when switching between the measuring positions with high and low concentration and vice versa. These properties may course serious errors for estimation of e.g. gas emissions whenever more than one measuring channel is applied. To reduce the measurement errors, some suggestions regarding design of the measurement setup and measuring strategies were presented.

  2. Time Delay for Aerial Ammonia Concentration Measurements in Livestock Buildings

    Directory of Open Access Journals (Sweden)

    Hans Benny Rom

    2010-05-01

    Full Text Available Correct measurements of ammonia concentration in air still present considerable challenges. The high water solubility and polarity can cause it to adsorb on surfaces in the entire sampling system, including sampling lines, filters, valves, pumps and instruments, causing substantial measuring errors and time delays. To estimate time delay characteristics of a Photo Acoustic Multi Gas Monitor 1312 and a Multi Point Sampler continuous measurement of aerial ammonia concentrations at different levels was performed. In order to obtain reproducible data, a wind tunnel was used to generate selected concentrations inside and a background concentration representing the air inlet of the tunnel. Four different concentration levels (0.8 ppm, 6.2 ppm, 9.7 ppm and 13.7 ppm were used in the experiments, with an additional outdoor concentration level as background. The results indicated a substantial time delay when switching between the measuring positions with high and low concentration and vice versa. These properties may course serious errors for estimation of e.g. gas emissions whenever more than one measuring channel is applied. To reduce the measurement errors, some suggestions regarding design of the measurement setup and measuring strategies were presented.

  3. Effect of ventilation regimen on the welfare and production performance of the lactating ewe in winter

    Directory of Open Access Journals (Sweden)

    L. Taibi

    2011-03-01

    Full Text Available The importance of efficient ventilation systems of animal houses is often underestimated during the winter season and this may result in a serious limitation to high efficiencies of production and good health of farmed livestock. Poor ventilation may lead to high levels of gaseous pollutants as well as to increased moisture content of the house air and condensation on internal surfaces. Both events may enhance the growth and multiplication of microorganisms in the air and in the litter (Sevi et al., 2001...

  4. Building Assessment Survey and Evaluation (BASE) Study: Summarized Data - Test Space HVAC Characteristics

    Science.gov (United States)

    Information on the characteristics of the heating, ventilation, and air conditioning (HVAC) system(s) in the entire BASE building including types of ventilation, equipment configurations, and operation and maintenance issues

  5. Building thermal loads: A case study for David Hellen Petta public secondary school

    CSIR Research Space (South Africa)

    Kumirai, T

    2013-03-01

    Full Text Available This chapter assesses the impact of appropriate passive interventions on building thermal loads. The passive interventions investigated are ceiling insulation, wall insulation, attic ventilation, natural ventilation and roof absorptance and also...

  6. A review on control system algorithm for building automation systems

    CSIR Research Space (South Africa)

    Noubissie-Tientcheu, SI

    2016-09-01

    Full Text Available The building with its components such as Heating Ventilation Air Conditioning (HVAC) and lighting constitute a bigger part of energy consumption in Southern Africa. Control system in a building reduced the energy consumption, according to different...

  7. Application of biotechnology to improve livestock products

    Directory of Open Access Journals (Sweden)

    Swati Gupta

    Full Text Available Biotechnological achievements of recent years have emerged as powerful tool to improve quality attributes of livestock products including milk and meat products. Biotechnological approaches can be employed for improving productivity, economy, physicochemical and nutritional attributes of a wide range of livestock products. The target areas of biotechnological research in the field of livestock products can be envisaged as production of high yielding food animal, improvement in quality of their products, enhanced production of natural food grade preservatives, efficient byproduct utilization and so forth. Many of the biotechnological techniques can be explored in the area of quality assurance programmes, which would be of great help to produce livestock products of assured quality and public health safety. [Vet World 2012; 5(10.000: 634-638

  8. Livestock and Climate Change: Two Views

    NARCIS (Netherlands)

    Zijpp, van der A.J.

    2008-01-01

    Livestock rearing contributes to climate change, but at the same time it brings many benefits to small-scale farmers. Do these benefits outweigh the disadvantages in terms of greenhouse gas emissions? And how can these emissions be reduced?

  9. Adapting livestock behaviour to achieve management goals

    Science.gov (United States)

    Using livestock to efficiently achieve management goals requires melding animal behavior with mechanical and electronic equipment. Practices such as autonomously obtaining individual animal liveweight when combined with individual animal electronic identification can produce numerous cost saving ad...

  10. [Ventilation-perfusion ratios].

    Science.gov (United States)

    Schaffartzik, W

    1994-10-01

    Knowledge of normal and impaired pulmonary gas exchange is essential to the anaesthesiologist. Analysis of an arterial blood sample allows evaluation of whether or not pulmonary gas exchange is normal. For this purpose comparison with the oxygenation index or the alveolar-arterial PO2 difference is helpful. Pathological changes of these variables are mainly caused by ventilation-perfusion (VA/Q) mismatch. In daily practice, venous admixture or intrapulmonary shunt can be calculated using arterial and mixed-venous blood. By analysing arterial and expired PCO2, dead-space ventilation can be determined, but extended analyses of VA/Q distribution are not possible in daily practice. However, knowledge of the principles of typical disturbances of pulmonary gas exchange in acute and chronic lung disease allows the use of therapeutic strategies based on the pathophysiological changes.

  11. Diffuse Ceiling Ventilation

    DEFF Research Database (Denmark)

    Zhang, Chen; Yu, Tao; Heiselberg, Per Kvols

    -cooling period and night cooling potential. The investment cost of this ventilation system is about 5-10% lower than the conventional ones, because the acoustic ceiling could be directly applied as air diffuser and the use of plenum to distribute air reduces the cost of ductwork. There is a growing interest...... and manufacturers and the users of diffuse ceiling technology. The design guide introduces the principle and key characteristics of room air distribution with diffuse ceiling ventilation. It provides an overview of potential benefit and limitations of this technology. The benefits include high thermal comfort, high...... cooling capacity, energy saving, low investment cost and low noise level; while the limitations include condensation risk and the limit on the room geometry. Furthermore, the crucial design parameters are summarized and their effects on the system performance are discussed. In addition to the stand...

  12. Analysis of Numerical Models for Dispersion of Chemical/Biological Agents in Complex Building Environments

    Science.gov (United States)

    2004-11-01

    variation in ventilation rates over time and the distribution of ventilation air within a building, and to estimate the impact of envelope air...bio) contaminants. This CH2M HILL research: (1) analyzed existing filtration technologies for building heating, ventilating , and air-conditioning...009XGG, “ERASP (Environmental Response and Secu- rity Protection)/HVAC (Heating, Ventilating and Air Conditioning).” The technical monitor was Dr

  13. BSim models for 2 case-studies of naturally and mechanically ventilated daycare institutions

    Energy Technology Data Exchange (ETDEWEB)

    Kalyanova, O.; Heiselberg, P.

    2009-06-15

    The report intends to provide complete information necessary for evaluation of assumptions made in the models and conclusions derived from the results of simulation of two different institutions in various operational modes. Thermal models are prepared for two day-care buildings, one which is mechanically ventilated and one which is naturally ventilated. All simulations were preformed in BSim, and all the models are simulated in the current version og BSim which is version 6,8,9,8. The results of the simulations showed that it is possible to reduce energy use for ventilation, both in mechanically and naturally ventilated child care center without compromising indoor air quality. (ln)

  14. Subjective evaluation of different ventilation concepts combined with radiant heating and cooling

    DEFF Research Database (Denmark)

    Krajcik, Michal; Tomasi, Roberta; Simone, Angela

    2012-01-01

    Sixteen subjects evaluated the indoor environment in four experiments with different combinations of ventilation and radiant heating/cooling systems. Two test setups simulated a room in a low energy building with a single occupant during winter. The room was equipped either by a ventilation system...... with displacement ventilation. Vertical air temperature distribution was more uniform for floor heating than for warm air heating, but there was no significant difference in thermal perception between the two mixing ventilation systems. For the summer conditions the subjects voted warmer than predicted by the PMV...

  15. Matching Livestock Production Systems and Environment

    Science.gov (United States)

    Becchetti, T.; Stackhouse, J.; Snell, L.; Lile, D.; George, H.; Harper, J. M.; Larson, S.; Mashiri, F.; Doran, M.; Barry, S.

    2015-12-01

    Livestock production systems vary greatly over the world. Producers try to match the resources they have with the demands of production, this can vary by species, class of animal, number of animals, and production goals, etc. Using California's diversity in production systems as an example, we explored how livestock producers best utilize the forage and feed found in different ecosystems and available in different parts of the state. Livestock grazing, the predominant land use in California and in much of the world, makes efficient use of the natural vegetation produced without additional water (irrigation), minimal inputs such as fertilizer while often supporting a variety of conservation objectives including vegetation management, fire fuels management, and habitat and open space conservation. The numerous by-products produced by other sectors of California's agriculture as well as food industries, such as brewer's grain, cottonseeds, and almond hulls are utilized as a feed source for livestock. These by-products are not only an important feed source especially in drought years but are diverted from our waste stream when utilized by livestock. The concept of matching available resources to livestock needs throughout the world is often overlooked and production systems are often over simplified in projects conducting a life cycle analysis or developing carbon foot prints for livestock production systems. This paper provides details on the various production systems found in California, the ecosystem they have adapted to, and how the producers use science and ecological knowledge to match the biological requirements of the livestock and conservation objectives to feed and forage resources.

  16. Climate change mitigation through livestock system transitions.

    Science.gov (United States)

    Havlík, Petr; Valin, Hugo; Herrero, Mario; Obersteiner, Michael; Schmid, Erwin; Rufino, Mariana C; Mosnier, Aline; Thornton, Philip K; Böttcher, Hannes; Conant, Richard T; Frank, Stefan; Fritz, Steffen; Fuss, Sabine; Kraxner, Florian; Notenbaert, An

    2014-03-11

    Livestock are responsible for 12% of anthropogenic greenhouse gas emissions. Sustainable intensification of livestock production systems might become a key climate mitigation technology. However, livestock production systems vary substantially, making the implementation of climate mitigation policies a formidable challenge. Here, we provide results from an economic model using a detailed and high-resolution representation of livestock production systems. We project that by 2030 autonomous transitions toward more efficient systems would decrease emissions by 736 million metric tons of carbon dioxide equivalent per year (MtCO2e⋅y(-1)), mainly through avoided emissions from the conversion of 162 Mha of natural land. A moderate mitigation policy targeting emissions from both the agricultural and land-use change sectors with a carbon price of US$10 per tCO2e could lead to an abatement of 3,223 MtCO2e⋅y(-1). Livestock system transitions would contribute 21% of the total abatement, intra- and interregional relocation of livestock production another 40%, and all other mechanisms would add 39%. A comparable abatement of 3,068 MtCO2e⋅y(-1) could be achieved also with a policy targeting only emissions from land-use change. Stringent climate policies might lead to reductions in food availability of up to 200 kcal per capita per day globally. We find that mitigation policies targeting emissions from land-use change are 5 to 10 times more efficient--measured in "total abatement calorie cost"--than policies targeting emissions from livestock only. Thus, fostering transitions toward more productive livestock production systems in combination with climate policies targeting the land-use change appears to be the most efficient lever to deliver desirable climate and food availability outcomes.

  17. Ventilation i industrien

    DEFF Research Database (Denmark)

    Valbjørn, O.

    I en række afsnit belyses problemer med træk, kulde, varme, og luftforurening på industriens arbejdspladser, og hvordan man ved ventilation og bygningsudformning kan bekæmpe disse gener. Hvert afsnit kan i princippet læses for sig, og anvisningen kan derfor bruges som håndbog, både af de der er...

  18. Noninvasive mechanical ventilation

    OpenAIRE

    Karakurt, Sait

    2016-01-01

    Noninvasive mechanical ventilation (NIMV) has been widelyapplied to the patient with respiratory failure since 1990’s aroundthe world. The respiratory function of the patient with respiratoryfailure should be supported by using positive pressure ventilationuntil primary problem of the patient is treated. Positive pressureshould be given noninvasively or invasively. If the patient isconscious (except unconsiousness due to CO2 retention) and hasintact bulber function(sufficient cough reflex and...

  19. SEPARATION OF MECHANICAL VENTILATION

    OpenAIRE

    Ida Bagus Wisnu Parbawa Kusuma; I Nengah Kuning Atmajaya

    2014-01-01

    The weaning from mechanical ventilation can be defined as the process of letting theventilator either directly or in stages. Indication of weaning from mechanicalventilation, seen from several parameters such as disease processes, PaO2, PEEP,FiO2, pH, Hb, awareness, body temperature, cardiac function, lung function, drugssedative agent or paralysis agent, and psicologic status of patient. Based on thelength of the weaning, can be devided into two, long-term weaning dan short-termweaning. Shor...

  20. Ventilation i industrien

    DEFF Research Database (Denmark)

    Valbjørn, O.

    I en række afsnit belyses problemer med træk, kulde, varme, og luftforurening på industriens arbejdspladser, og hvordan man ved ventilation og bygningsudformning kan bekæmpe disse gener. Hvert afsnit kan i princippet læses for sig, og anvisningen kan derfor bruges som håndbog, både af de der er u...

  1. Purge ventilation operability

    Energy Technology Data Exchange (ETDEWEB)

    Marella, J.R.

    1995-04-10

    A determination of minimum requirements for purge exhaust ventilation system operability has been performed. HLWE and HLW Regulatory Program personnel have evaluated the various scenarios of equipment conditions and HLWE has developed the requirements for purge exhaust systems. This report is provided to document operability requirements to assist Tank Farm personnel to determine whether a system is operable/inoperable and to define required compensatory actions.

  2. A South African perspective on livestock production in relation to ...

    African Journals Online (AJOL)

    The general perception that livestock is a major contributor to global warming resulted mainly from the FAO publication, Livestock's Long Shadow, in 2006, which ... An effective way to reduce the carbon and water footprint of livestock is to decrease livestock numbers and increase production per animal, thereby improving ...

  3. Policy opportunities to enhance the role of smallholder livestock ...

    African Journals Online (AJOL)

    Very few livestock projects were funded. The success rate of institutional interventions was low. We argue that smallholder livestock systems offer policy opportunities to realise post-apartheid reform goals in the smallholder livestock sector. The premises are; there are more livestock in communal smallholder sector than in ...

  4. Estimating influence of stocking regimes on livestock grazing distributions

    Science.gov (United States)

    Matthew J. Rinella; Marty Vavra; Bridgett J. Naylor; Jennifer M. Boyd

    2011-01-01

    Livestock often concentrate grazing in particular regions of landscapes while partly or wholly avoiding other regions. Dispersing livestock from the heavily grazed regions is a central challenge in grazing land management. Position data gathered from GPS-collared livestock hold potential for increasing knowledge of factors driving livestock aggregation patterns, but...

  5. livestock husbandry and economic-sustainability of small farmers

    African Journals Online (AJOL)

    Osondu

    The study attempts livestock husbandry and sustainability of small farmers in West Gojjam region, Ethiopia where a ... and their engagement in different operations of livestock husbandry for economic sustainability. Systematic random sampling was ..... sell and purchase livestock from the livestock markets and within village ...

  6. Existing Whole-House Solutions Case Study: Multifamily Individual Heating and Ventilation Systems, Lawrence, Massachusetts

    Energy Technology Data Exchange (ETDEWEB)

    None

    2013-11-01

    The conversion of an older Massachusetts building into condominiums illustrates a safe, durable, and cost-effective solution for heating and ventilation systems that can potentially benefit millions of multifamily buildings. In this project, Merrimack Valley Habitat for Humanity (MVHfH) partnered with U.S. Department of Energy Building America team Building Science Corporation (BSC) to provide high performance affordable housing for 10 families in the retrofit of an existing mass masonry building (a former convent).

  7. Healthy Building Design for the Commercial, Industrial, and Institutional Marketplace.

    Science.gov (United States)

    Turner, William A.

    Building design and construction that helps deliver both superior air quality and occupant thermal comfort, while minimizing energy consumption, are examined. The paper explores an integrated building systems approach that combines the principles of "directed air flow control" and "demand controlled ventilation" where ventilation is effectively…

  8. Reducing Building HVAC Costs with Site-Recovery Energy

    Science.gov (United States)

    Pargeter, Stephen J.

    2012-01-01

    Building owners are caught between two powerful forces--the need to lower energy costs and the need to meet or exceed outdoor air ventilation regulations for occupant health and comfort. Large amounts of energy are wasted each day from commercial, institutional, and government building sites as heating, ventilation, and air conditioning (HVAC)…

  9. Determination of utilizable wind energy for indoor ventilation in ...

    African Journals Online (AJOL)

    Presented is the analysis of hourly wind data for 15 stations across Nigeria acquired from the Nigerian Meteorological Agency mostly covering the period of five years for purposes of wind energy utilisation for indoor ventilation in buildings. Weibull's distribution function was used for modeling of wind speed frequency ...

  10. Design analysis, selection and application of fans for ventilation and ...

    African Journals Online (AJOL)

    ... fluid mechanics and head losses due to friction and across fittings were considered. Practical illustrations are provided for ducted and non-ducted ventilation and air conditioned distribution in buildings. The use of characteristic curves for selection of fans is also discussed. Journal of Applied Science and Technology Vol.

  11. Design of energy efficient ventilation and air-conditioning systems

    CERN Document Server

    Seppänen, Olli; Bertilsson, Thore; Maripuu, Mari-Liis; Lamy, Hervé; Vanden Borre, Alex

    2012-01-01

    This guidebook covers numerous system components of ventilation and air-conditioning systems and shows how they can be improved by applying the latest technology products. Special attention is paid to details, which are often overlooked in the daily design practice, resulting in poor performance of high quality products once they are installed in the building system.

  12. Impact of Air Distribution on Heat Transfer during Night-Time Ventilation

    DEFF Research Database (Denmark)

    Heiselberg, Per; Artmann, Nikolai; Jensen, Rasmus Lund

    2009-01-01

    Passive cooling by night-time ventilation is seen as a promising approach for energy efficient cooling of buildings. However, uncertainties in prediction of cooling potential and consequenses for thermal comfort restrain architects and engineers from applying this technique. Heat transfer...... ventilation becomes most efficient. A design chart to estimate the performance of night-time cooling during an early stage of building design is proposed....

  13. Indoor Chemistry: Materials, Ventilation Systems, and Occupant Activities

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, G.C.; Corsi, R.L.; Destaillats, H.; Nazaroff, W.W.; Wells, J.R.

    2006-05-01

    Chemical processes taking place in indoor environments can significantly alter the nature and concentrations of pollutants. Exposure to secondary contaminants generated in these reactions needs to be evaluated in association with many aspects of buildings to minimize their impact on occupant health and well-being. Focusing on indoor ozone chemistry, we describe alternatives for improving indoor air quality by controlling chemical changes related to building materials, ventilation systems, and occupant activities.

  14. Mould growth on building materials

    DEFF Research Database (Denmark)

    Fog Nielsen, K.

    Mould growth in buildings is associated with adverse health effects among the occupants of the building. However actual growth only occurs in damp and water-damaged materials, and is an increasing problem in Denmark, due to less robust constructions, inadequate maintenance, and too little...... ventilation. This project was started to determine if mycotoxins are produced in damp and water-damaged buildings as well investigating the influence of environmental conditions (humidity and temperature) on the production of fungal growth and secondary metabolism....

  15. Livestock and health: understanding the links between agriculture and health

    OpenAIRE

    Catelo, Maria Angeles

    2006-01-01

    "The linkages between livestock and health are significant, particularly for the poor, whether as livestock raisers or as consumers of meat and milk, or even as users of the environment. The processes of livestock production and consumption bring both benefits and problems for human health... Livestock production and consumption can lead to four main types of human health risks: (1) diseases transmitted from livestock to humans; (2) environmental pollution; (3) foodborne diseases and risks; a...

  16. Climate change and livestock: Impacts, adaptation, and mitigation

    OpenAIRE

    M. Melissa Rojas-Downing; A. Pouyan Nejadhashemi; Timothy Harrigan; Sean A. Woznicki

    2017-01-01

    Global demand for livestock products is expected to double by 2050, mainly due to improvement in the worldwide standard of living. Meanwhile, climate change is a threat to livestock production because of the impact on quality of feed crop and forage, water availability, animal and milk production, livestock diseases, animal reproduction, and biodiversity. This study reviews the global impacts of climate change on livestock production, the contribution of livestock production to climate change...

  17. Effects of ventilation behaviour on indoor heat load based on test reference years

    Science.gov (United States)

    Rosenfelder, Madeleine; Koppe, Christina; Pfafferott, Jens; Matzarakis, Andreas

    2016-02-01

    Since 2003, most European countries established heat health warning systems to alert the population to heat load. Heat health warning systems are based on predicted meteorological conditions outdoors. But the majority of the European population spends a substantial amount of time indoors, and indoor thermal conditions can differ substantially from outdoor conditions. The German Meteorological Service (Deutscher Wetterdienst, DWD) extended the existing heat health warning system (HHWS) with a thermal building simulation model to consider heat load indoors. In this study, the thermal building simulation model is used to simulate a standardized building representing a modern nursing home, because elderly and sick people are most sensitive to heat stress. Different types of natural ventilation were simulated. Based on current and future test reference years, changes in the future heat load indoors were analyzed. Results show differences between the various ventilation options and the possibility to minimize the thermal heat stress during summer by using an appropriate ventilation method. Nighttime ventilation for indoor thermal comfort is most important. A fully opened window at nighttime and the 2-h ventilation in the morning and evening are more sufficient to avoid heat stress than a tilted window at nighttime and the 1-h ventilation in the morning and the evening. Especially the ventilation in the morning seems to be effective to keep the heat load indoors low. Comparing the results for the current and the future test reference years, an increase of heat stress on all ventilation types can be recognized.

  18. Short-term airing by natural ventilation - implication on IAQ and thermal comfort.

    Science.gov (United States)

    Heiselberg, P; Perino, M

    2010-04-01

    The need to improve the energy efficiency of buildings requires new and more efficient ventilation systems. It has been demonstrated that innovative operating concepts that make use of natural ventilation seem to be more appreciated by occupants. Among the available ventilation strategies that are currently available, buoyancy driven, single-sided natural ventilation has proved to be very effective and can provide high air change rates for temperature and Indoor Air Quality (IAQ) control. However, to promote a wider distribution of these systems an improvement in the knowledge of their working principles is necessary. The present study analyses and presents the results of an experimental evaluation of airing performance in terms of ventilation characteristics, IAQ and thermal comfort. It includes investigations of the consequences of opening time, opening frequency, opening area and expected airflow rate, ventilation efficiency, thermal comfort and dynamic temperature conditions. A suitable laboratory test rig was developed to perform extensive experimental analyses of the phenomenon under controlled and repeatable conditions. The results showed that short-term window airing is very effective and can provide both acceptable IAQ and thermal comfort conditions in buildings. Practical Implications This study gives the necessary background and in-depth knowledge of the performance of window airing by single-sided natural ventilation necessary for the development of control strategies for window airing (length of opening period and opening frequency) for optimum IAQ and thermal comfort in naturally ventilated buildings.

  19. Guide to Closing and Conditioning Ventilated Crawlspaces

    Energy Technology Data Exchange (ETDEWEB)

    Dickson, B.

    2013-01-01

    This how-to guide explains the issues and concerns with conventional ventilated crawlspaces and provides prescriptive measures for improvements that will create healthier and more durable spaces. The methods described in this guide are not the only acceptable ways to treat a crawlspace but represent a proven strategy that works in many areas of the United States. The designs discussed in this guide may or may not meet the local building codes and as such will need to be researched before beginning the project.

  20. Building technical services - Compact equipment for heating, hot water preparation, ventilation and cooling - Final report; Haustechnik - Kompaktgeraete (Heizen, Warmwasser, Lueften, Kuehlen - alles aus einem). Erkenntnisse aus der Praxis - Schlussbericht

    Energy Technology Data Exchange (ETDEWEB)

    Haessig, W.; Streit, S. [Haessig Sustech GmbH, Uster (Switzerland); Helfenfinger, D.; Keller, P. [Hochschule fuer Technik und Architektur Luzern (HSLU), Luzern (Switzerland)

    2009-06-15

    This comprehensive final report for the Swiss Federal Office of Energy (SFOE) presents and discusses the knowledge gained in practice concerning compact equipment that can be used for heating, hot water preparation, ventilation and cooling. Such units combine heat-pumps and the further equipment necessary. Data on various factors were collected over a period of one year in three apartment blocks that meet Swiss Minergie-P very low energy consumption standards. Apart from the above mentioned factors, the study also considered humidity and carbon dioxide levels in the apartments and inhabitant behaviour. The authors note that the energy consumption of several apartments fell below the Minergie-P limiting, annual value of 30 kWh/m2. An increase in electricity consumption dependent on room temperatures is noted and commented on. The economic feasibility of Minergie-P and so-called passive housing is commented on.

  1. The influence of ventilation on moisture conditions in facades with wooden cladding

    DEFF Research Database (Denmark)

    Hansen, Ernst Jan de Place; Brandt, Erik

    2009-01-01

    for mould growth on wood-based materials. The paper presents results from the investigation with emphasis on a discussion of the effect of cavity ventilation on moisture content in timber frame walls. In terms of moisture content behind the wind barrier, the behaviour of wood frame walls with a non......-ventilated cavity was found not to be inferior to the behaviour of wood frame walls with a ventilated cavity.......A ventilated cavity behind the cladding of timber frame walls is often considered good building practice that facilitates the removal of moisture from the construction. However, moisture will only be removed from the construction by ventilating it with dry air, whereas ventilating with humid air...

  2. Pretest Predictions for Ventilation Tests

    Energy Technology Data Exchange (ETDEWEB)

    Y. Sun; H. Yang; H.N. Kalia

    2007-01-17

    The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, concrete pipe walls, and insulation that will be developed during the ventilation tests involving various test conditions. The results will be used as input to the following three areas: (1) Decisions regarding testing set-up and performance. (2) Assessing how best to scale the test phenomena measured. (3) Validating numerical approach for modeling continuous ventilation. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the ventilation tests, and develop and describe numerical methods that can be used to calculate the effects of continuous ventilation. Sensitivity studies to assess the impact of variation of linear power densities (linear heat loads) and ventilation air flow rates are included. The calculation is limited to thermal effect only.

  3. Mechanical ventilation in neurosurgical patients

    OpenAIRE

    Keshav Goyal; Ranadhir Mitra; Shweta Kedia

    2013-01-01

    Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical pa...

  4. Mechanical ventilation in neurosurgical patients

    Directory of Open Access Journals (Sweden)

    Keshav Goyal

    2013-01-01

    Full Text Available Mechanical ventilation significantly affects cerebral oxygenation and cerebral blood flow through changes in arterial carbon dioxide levels. Neurosurgical patients might require mechanical ventilation for correction and maintenance of changes in the pulmonary system that occur either due to neurosurgical pathology or following surgery during the acute phase. This review discusses the basics of mechanical ventilation relevant to the neurosurgeon in the day-to-day management of neurosurgical patient requiring artificial support of the respiration.

  5. Ventilation Surge Techniques. Volume I

    Science.gov (United States)

    1981-12-01

    Whon Data Rntere), 20. The experimental program examined airflow patterns for both mechanically driven and thermally driven ventilation . Mechanical ...were used in the study. *The experimental program examined airflow patterns for both mechanically driven and thermally driven ventilation . Mechanical ... Ventilation can be supplied by mechanical means such as fans, blowers, and pumps or by natural forces such’as those created by wind or thermal buoyancy. The

  6. Revised spatially distributed global livestock emissions

    Science.gov (United States)

    Asrar, G.; Wolf, J.; West, T. O.

    2015-12-01

    Livestock play an important role in agricultural carbon cycling through consumption of biomass and emissions of methane. Quantification and spatial distribution of methane and carbon dioxide produced by livestock is needed to develop bottom-up estimates for carbon monitoring. These estimates serve as stand-alone international emissions estimates, as input to global emissions modeling, and as comparisons or constraints to flux estimates from atmospheric inversion models. Recent results for the US suggest that the 2006 IPCC default coefficients may underestimate livestock methane emissions. In this project, revised coefficients were calculated for cattle and swine in all global regions, based on reported changes in body mass, quality and quantity of feed, milk production, and management of living animals and manure for these regions. New estimates of livestock methane and carbon dioxide emissions were calculated using the revised coefficients and global livestock population data. Spatial distribution of population data and associated fluxes was conducted using the MODIS Land Cover Type 5, version 5.1 (i.e. MCD12Q1 data product), and a previously published downscaling algorithm for reconciling inventory and satellite-based land cover data at 0.05 degree resolution. Preliminary results for 2013 indicate greater emissions than those calculated using the IPCC 2006 coefficients. Global total enteric fermentation methane increased by 6%, while manure management methane increased by 38%, with variation among species and regions resulting in improved spatial distributions of livestock emissions. These new estimates of total livestock methane are comparable to other recently reported studies for the entire US and the State of California. These new regional/global estimates will improve the ability to reconcile top-down and bottom-up estimates of methane production as well as provide updated global estimates for use in development and evaluation of Earth system models.

  7. Pluripotent stem cells and livestock genetic engineering.

    Science.gov (United States)

    Soto, Delia A; Ross, Pablo J

    2016-06-01

    The unlimited proliferative ability and capacity to contribute to germline chimeras make pluripotent embryonic stem cells (ESCs) perfect candidates for complex genetic engineering. The utility of ESCs is best exemplified by the numerous genetic models that have been developed in mice, for which such cells are readily available. However, the traditional systems for mouse genetic engineering may not be practical for livestock species, as it requires several generations of mating and selection in order to establish homozygous founders. Nevertheless, the self-renewal and pluripotent characteristics of ESCs could provide advantages for livestock genetic engineering such as ease of genetic manipulation and improved efficiency of cloning by nuclear transplantation. These advantages have resulted in many attempts to isolate livestock ESCs, yet it has been generally concluded that the culture conditions tested so far are not supportive of livestock ESCs self-renewal and proliferation. In contrast, there are numerous reports of derivation of livestock induced pluripotent stem cells (iPSCs), with demonstrated capacity for long term proliferation and in vivo pluripotency, as indicated by teratoma formation assay. However, to what extent these iPSCs represent fully reprogrammed PSCs remains controversial, as most livestock iPSCs depend on continuous expression of reprogramming factors. Moreover, germline chimerism has not been robustly demonstrated, with only one successful report with very low efficiency. Therefore, even 34 years after derivation of mouse ESCs and their extensive use in the generation of genetic models, the livestock genetic engineering field can stand to gain enormously from continued investigations into the derivation and application of ESCs and iPSCs.

  8. Sustainability of livestock production systems : a comparing conventional and organic livestock husbandry

    NARCIS (Netherlands)

    Wagenberg, van C.P.A.; Haas, de Y.; Hogeveen, H.; Krimpen, van M.M.; Meuwissen, M.P.M.; Middelaar, van C.E.; Rodenburg, T.B.

    2016-01-01

    Sustainable livestock production systems are needed to feed the larger, more urban, richer and older world population in 2050. Quantitative information about the sustainability performance of existing livestock production systems can aid the debate of which actions could be developed and

  9. Use of Recirculating Ventilation With Dust Filtration to Improve Wintertime Air Quality in a Swine Farrowing Room.

    Science.gov (United States)

    Anthony, T Renée; Altmaier, Ralph; Jones, Samuel; Gassman, Rich; Park, Jae Hong; Peters, Thomas M

    2015-01-01

    The performance of a recirculating ventilation system with dust filtration was evaluated to determine its effectiveness to improve the air quality in a swine farrowing room of a concentrated animal feeding operation (CAFO). Air was exhausted from the room (0.47 m(3) sec(-1); 1000 cfm), treated with a filtration unit (Shaker-Dust Collector), and returned to the farrowing room to reduce dust concentrations while retaining heat necessary for livestock health. The air quality in the room was assessed over a winter, during which time limited fresh air is traditionally brought into the building. Over the study period, dust concentrations ranged from 0.005-0.31 mg m(-3) (respirable) and 0.17-2.09 mg m(-3) (inhalable). In-room dust concentrations were reduced (41% for respirable and 33% for inhalable) with the system in operation, while gas concentrations (ammonia [NH3], hydrogen sulfide [H2S], carbon monoxide [CO], carbon dioxide [CO2]) were unchanged. The position of the exhaust and return air systems provided reasonably uniform contaminant distributions, although the respirable dust concentrations nearest one of the exhaust ducts was statistically higher than other locations in the room, with differences averaging only 0.05 mg m(-3). Throughout the study, CO2 concentrations consistently exceeded 1540 ppm (industry recommendations) and on eight of the 18 study days it exceeded 2500 ppm (50% of the ACGIH TLV), with significantly higher concentrations near a door to a temperature-controlled hallway that was typically often left open. Alternative heaters are recommended to reduce CO2 concentrations in the room. Contaminant concentrations were modeled using production and environmental factors, with NH3 related to the number of sow in the room and outdoor temperatures and CO2 related to the number of piglets and outdoor temperatures. The recirculating ventilation system provided dust reduction without increasing concentrations of hazardous gases.

  10. Long-Term Mechanical Ventilation.

    Science.gov (United States)

    Sahetya, Sarina; Allgood, Sarah; Gay, Peter C; Lechtzin, Noah

    2016-12-01

    Although precise numbers are difficult to obtain, the population of patients receiving long-term ventilation has increased over the last 20 years, and includes patients with chronic lung diseases, neuromuscular diseases, spinal cord injury, and children with complex disorders. This article reviews the equipment and logistics involved with ventilation outside of the hospital. Discussed are common locations for long-term ventilation, airway and secretion management, and many of the potential challenges faced by individuals on long-term ventilation. Published by Elsevier Inc.

  11. Monitoring during Mechnical Ventilation

    Directory of Open Access Journals (Sweden)

    Dean Hess

    1996-01-01

    Full Text Available Monitoring is a continuous, or nearly continuous, evaluation of the physiological function of a patient in real time to guide management decisions, including when to make therapeutic interventions and assessment of those interventions. Pulse oximeters pass two wavelengths of light through a pulsating vascular bed and determine oxygen saturation. The accuracy of pulse oximetry is about ±4%. Capnography measures carbon dioxide at the airway and displays a waveform called the capnogram. End-tidal PCO2 represents alveolar PCO2 and is determined by the ventilation-perfusion quotient. Use of end-tidal PCO2 as an indication of arterial PCO2 is often deceiving and incorrect in critically ill patients. Because there is normally very little carbon dioxide in the stomach, a useful application of capnography is the detection of esophageal intubation. Intra-arterial blood gas systems are available, but the clinical impact and cost effectiveness of these is unclear. Mixed venous oxygenation (PvO2 or SvO2 is a global indicator of tissue oxygenation and is affected by arterial oxygen content, oxygen consumption and cardiac output. Indirect calorimetry is the calculation of energy expenditure and respiratory quotient by the measurement of oxygen consumption and carbon dioxide production. A variety of mechanics can be determined in mechanically ventilated patients including resistance, compliance, auto-peak end-expiratory pressure (PEEP and work of breathing. The static pressure-volume curve can be used to identify lower and upper infection points, which can be used to determine the appropriate PEEP setting and to avoid alveolar overdistension. Although some forms of monitoring have become a standard of care during mechanical ventilation (eg, pulse oximetry, there is little evidence that use of any monitor affects patient outcome.

  12. Plane Stratified Flow in a Room Ventilated by Displacement Ventilation

    DEFF Research Database (Denmark)

    Nielsen, Peter Vilhelm; Nickel, J.; Baron, D. J. G.

    2004-01-01

    The air movement in the occupied zone of a room ventilated by displacement ventilation exists as a stratified flow along the floor. This flow can be radial or plane according to the number of wall-mounted diffusers and the room geometry. The paper addresses the situations where plane flow...

  13. Study of heat-stress levels in naturally ventilated sheep barns during heat waves: development and assessment of regression models

    Science.gov (United States)

    Papanastasiou, D. K.; Bartzanas, T.; Panagakis, P.; Zhang, G.; Kittas, C.

    2016-11-01

    It is well documented that heat-stress burdens sheep welfare and productivity. Peak heat-stress levels are observed when high temperatures prevail, i.e. during heat waves; however, continuous measurements inside livestock buildings are not usually available for long periods so as to study the variation of summer heat-stress levels for several years, especially during extreme hot weather. Α methodology to develop a long time series of summer temperature and relative humidity inside naturally ventilated sheep barns is proposed. The accuracy and the transferability of the developed linear regression models were verified. Temperature Humidity Index (THI) was used to assess sheep's potential heat-stress. Τhe variation of THI inside a barn during heat wave and non-heat wave days was examined, and the results were comparatively assessed. The analysis showed that sheep were exposed to moderate, severe, and extreme severe heat-stress in 10, 21 and 66 % of hours, respectively, during heat wave days, while the corresponding values during non-heat wave days were 14, 33 and 43 %, respectively. The heat load on sheep was much higher during heat wave events than during non-heat wave periods. Additionally, based on the averaged diurnal variation of THI, it was concluded that extreme severe heat-stress conditions were prevailing between 1000 and 2400 hours local time during heat wave days. Cool off night periods were never and extremely rarely detected during heat wave and non-heat wave days, respectively.

  14. Ozone Reductions Using Residential Building Envelopes

    Energy Technology Data Exchange (ETDEWEB)

    Walker, Iain S.; Sherman, Max; Nazaroff, William W.

    2009-02-01

    Ozone is an air pollutant with that can have significant health effects and a significant source of ozone in some regions of California is outdoor air. Because people spend the vast majority of their time indoors, reduction in indoor levels of ozone could lead to improved health for many California residents. Ozone is removed from indoor air by surface reactions and can also be filtered by building envelopes. The magnitude of the envelope impact depends on the specific building materials that the air flows over and the geometry of the air flow paths through the envelope that can be changes by mechanical ventilation operation. The 2008 Residential Building Standards in California include minimum requirements for mechanical ventilation by referencing ASHRAE Standard 62.2. This study examines the changes in indoor ozone depending on the mechanical ventilation system selected to meet these requirements. This study used detailed simulations of ventilation in a house to examine the impacts of different ventilation systems on indoor ozone concentrations. The simulation results showed that staying indoors reduces exposure to ozone by 80percent to 90percent, that exhaust ventilation systems lead to lower indoor ozone concentrations, that opening of windows should be avoided at times of high outdoor ozone, and that changing the time at which mechanical ventilation occurs has the ability to halve exposure to ozone. Future work should focus on the products of ozone reactions in the building envelope and the fate of these products with respect to indoor exposures.

  15. [Air quality control systems: heating, ventilating, and air conditioning (HVAC)].

    Science.gov (United States)

    Bellucci Sessa, R; Riccio, G

    2004-01-01

    After a brief illustration of the principal layout schemes of Heating, Ventilating, and Air Conditioning (HVAC), the first part of this paper summarizes the standards, both voluntary and compulsory, regulating HVAC facilities design and installation with regard to the question of Indoor Air Quality (IAQ). The paper then examines the problem of ventilation systems maintenance and the essential hygienistic requirements in whose absence HVAC facilities may become a risk factor for people working or living in the building. Lastly, the paper deals with HVAC design strategies and methods, which aim not only to satisfy comfort and air quality requirements, but also to ensure easy and effective maintenance procedures.

  16. Occupant Interactions and Effectiveness of Natural Ventilation Strategies in Contemporary New Housing in Scotland, UK.

    Science.gov (United States)

    Sharpe, Tim; Farren, Paul; Howieson, Stirling; Tuohy, Paul; McQuillan, Jonathan

    2015-07-21

    The need to reduce carbon emissions and fuel poverty has led to increased building envelope air tightness, intended to reduce uncontrolled ventilation heat losses. Ventilation strategies in dwellings still allow the use of trickle ventilators in window frames for background ventilation. The extent to which this results in "healthy" Indoor Air Quality (IAQ) in recently constructed dwellings was a concern of regulators in Scotland. This paper describes research to explore this. First a review of literature was conducted, then data on occupant interactions with ventilation provisions (windows, doors, trickle vents) gathered through an interview-based survey of 200 recently constructed dwellings, and measurements made on a sample of 40 of these. The main measured parameter discussed here is CO2 concentration. It was concluded after the literature review that 1000 ppm absolute was a reasonable threshold to use for "adequate" ventilation. The occupant survey found that there was very little occupant interaction with the trickle ventilators e.g., in bedrooms 63% were always closed, 28% always open, and in only 9% of cases occupants intervened to make occasional adjustments. In the measured dwellings average bedroom CO2 levels of 1520 ppm during occupied (night time) hours were observed. Where windows were open the average bedroom CO2 levels were 972 ppm. With windows closed, the combination of "trickle ventilators open plus doors open" gave an average of 1021 ppm. "Trickle ventilators open" gave an average of 1571 ppm. All other combinations gave averages of 1550 to 2000 ppm. Ventilation rates and air change rates were estimated from measured CO2 levels, for all dwellings calculated ventilation rate was less than 8 L/s/p, in 42% of cases calculated air change rate was less than 0.5 ach. It was concluded that trickle ventilation as installed and used is ineffective in meeting desired ventilation rates, evidenced by high CO2 levels reported across the sampled dwellings

  17. Monitoring ventilation during anesthesia.

    Science.gov (United States)

    Kay, B

    1978-01-01

    In patients under anesthesia, ventilation is often monitored less adequately than circulation. A simple method, neglected in adults, is the use of a precordial or oesophageal stethoscope. Respiratory volumes may be measured directly, or inferred from flowrates or pressure changes. A rough measurement of inspired volumes may be made using a nonrebreathing valve, and controlling fresh gas input to maintain a constant underfilled reservoir bag. Spirometry of expired volumes is difficult and requires sophisticated apparatus. Respiratory volumes are easily inferred from flowrates using the Wright or Dräger respirometers. Flowrates may also be inferred from pressure changes, which are easy to record, as in the pneumotachorgraph. Accurate measurements require attention to many details, such as linearity of the transducer response over the flowrates measured. Calibration should be with the anesthetic gases used, at controlled temperature and humidity. Positive pressure ventilation peaks give a high flow artefact, and electronic drift requires regular recalibration. Electrical impedance changes may also be used to infer and record respiratory volumes, with reasonable accuracy if individual calibration is carried out. Anesthesia offers excellent opportunities to measure compliance and resistance, but itself changes these values, so that relation to normal values or changes due to pathology is difficult. Occlusion pressure is also readily measured during anesthesia, as an indication of respiratory drive, but rigid control of all other factors affecting respiratory muscle tensions is necessary.

  18. Light and Ventilation Analysis for Infrastructure in an Urban Region - A Case Study

    Directory of Open Access Journals (Sweden)

    Awkash Kumar

    2017-07-01

    Full Text Available Pressure on infrastructure due to over population has deteriorated the indoor environment causing various health issues. It has also contributed to the sick building syndrome making huge monetary burden to economy. Public health department of the country has taken many actions to mitigate these issues however; design of the building was not taken into consideration. Optimum quantities of light and proper ventilation express the quality of indoor environment. Also, the use of natural light and ventilation is definitely an advantage with the raising concerns regarding the cost and environmental impact of energy use. Natural light and ventilation can reduce building construction and operation costs and reduce the energy consumption. Moreover it would also ensure safe, healthy and comfortable living conditions. Therefore, it is very important to assess indoor environment before implementing new construction or building. This provides theoretical guidelines and basic calculations for understanding a green infrastructures and the factors related to it. In this paper, a building has been studied in an urban city of India where the percentage area of light and ventilation were analyzed Analysis showed the percentage of light is thrice and ventilation is twice the prescribed limits by Indian Green Building Council (IGBC. It has been found that building under study fulfills the given criteria by IGBC. This analysis can be useful while constructing a new infrastructure to improve the standard of living as 90% time is spent indoors.

  19. Research on the Impact of Wind Angles on the Residential Building Energy Consumption

    OpenAIRE

    Zou Huifen; Yang Fuhua; Zhang Qian

    2014-01-01

    Wind angles affect building’s natural ventilation and also energy consumption of the building. In winter, the wind direction in the outdoor environment will affect heat loss of the building, while in summer the change of wind direction and speed in the outdoor environment will affect the building’s ventilation and indoor air circulation. So, making a good deal with the issue of the angle between local buildings and the dominant wind direction can effectively solve the winter and summer ventil...

  20. Thermal plumes in ventilated rooms

    DEFF Research Database (Denmark)

    Kofoed, Peter; Nielsen, Peter V.

    1990-01-01

    The design of a displacement ventilation system involves determination of the flow rate in the thermal plumes. The flow rate in the plumes and the vertical temperature gradient influence each other, and they are influenced by many factors. This paper shows some descriptions of these effects. Free...... to be the only possible approach to obtain the volume flow in: thermal plumes in ventilated rooms....