WorldWideScience

Sample records for vena tech lp

  1. Placement of the VenaTech LP Caval Filter in the Elderly: Feasibility and Clinical Benefits of Insertion Via the Arm

    International Nuclear Information System (INIS)

    Le Blanche, Alain F.; Pautas, Eric; Gouin, Isabelle; Baguees, Audrey; Piette, Francois; Chaibi, Pascal

    2005-01-01

    Purpose. To evaluate routine use of access sites in the arm for percutaneous caval filter placement (PCFP) in elderly patients. Neck arthritis, patient anxiety, access site thrombosis or fecal/urinary incontinence complicating jugular or femoral access may require alternative access sites in this population. Methods. Access via the right arm was chosen for PCFP (VenaTech LP). The indication for PCFP was deep vein thrombosis, a history of pulmonary embolism, and a contraindication to anticoagulant therapy. Ultrasound-guided puncture was performed after diameter measurement of the arm veins (O AV ). The filter was inserted with standard imaging procedures. Procedural difficulty was graded and compared with O AV and the angle from the arm vein to the superior vena cava (α AV/SVC ). Results. Over 2 years, 16 patients (14 women, 2 men) with an average age of 90 years (range 79-97 years) were included in the study. The average O AV value of the basilic or brachial veins was 4.2 mm (range 3.0-5.1 mm). The minimal O AV for successful access was determined after the first 15 patients. No hematoma occurred at the puncture sites. The average α AV/SVC value was 62 deg. (range 29 deg. - 90 deg.). Arm access was possible in 12 of 16 patients (75%) with O AV ≥ 3.5 mm and α AV/SVC ≥ 29 deg. Every procedure via the arm was graded 'easy' by the operator, regardless of angulation values. Femoral access was used in one case due to the impossibility of traversing the heart (patient no. 2), and jugular access was used in 3 of 16 (19%) patients due to puncture failure (patient no. 4), small O AV (3 mm) (patient no. 6), and stenosis of the distal right subclavian vein (patient no.16), respectively. Conclusion. PCFP via the arm can be routinely accomplished in patients older than 75 years, provided O AV ≥ 3.5 mm, and α AV/SVC ≥ 29 deg

  2. The Lp Lp Lp-curvature images of convex bodies and Lp Lp Lp

    Indian Academy of Sciences (India)

    Associated with the Lp-curvature image defined by Lutwak, some inequali- ... theory. With it, Lutwak [10] generalized many affine isoperimetric inequalities from their ... For quick reference, we recall some basic properties of Lp-mixed and dual ...

  3. Tech House

    Science.gov (United States)

    1978-01-01

    The members of the Swain family- Dr. Charles "Bill" Swain, wife Elaine, daughter Carol, 17, son "Chuck", 12, and dog Susie have an interesting assignment. They are active participants in an important NASA research program involving the application of space-age technology to home construction. b' Transplanted Floridians, the Swains now reside in NASA's Tech House, loatedat Langley Research Center, Hampton, Virginia. Their job is to use and help evaluate the variety of advanced technology systems in Tech House. A contemporary three-bedroom home, Tech House incorporates NASA technology, the latest commercial building techniques and other innovations, all designed to reduce energy and water consumption and to provide new levels of comfort, convenience, security and fire safety. Tech House equipment performed well in initial tests, but a house is not a home until it has people. That's where the Swains come in. NASA wants to see how the various systems work under actual living conditions, to confirm the effectiveness of the innovations or to determine necessary modifications for improvement. The Swains are occupying the house for a year, during which NASA engineers are computer monitoring the equipment and assembling a record of day-to-day performance. . Tech House is a laboratory rather than a mass production prototype, but its many benefits may influence home design and construction. In a period of sharply rising utility costs, widespread adoption of Tech House features could provide large-scale savings to homeowners and potentially enormous national benefit in resources conservation. Most innovations are aerospace spinoffs: Some of the equipment is now commercially available; other systems are expected to be in production within a few years. Around 1980, a Tech House-type of home could be built for $45-50,000 (1 976 dollars). It is estimated that the homeowner would save well over $20,000 (again 1976 dollars) in utility costs over the average mortgage span of 20 years.

  4. The Optional VenaTech™ Convertible™ Vena Cava Filter: Experimental Study in Sheep

    International Nuclear Information System (INIS)

    Le Blanche, Alain F.; Ricco, Jean-Baptiste; Bonneau, Michel; Reynaud, Philippe

    2012-01-01

    Purpose: Retrieval of optional caval filters may be impaired by filter tilting, migration, fracture, or embedding in the IVC wall. The goal of this experimental study was to evaluate a new optional filter, convertible by unlocking and removing the filter head. Methods: Forty-nine Pre-Alp sheep (average weight, 55 kg) were anesthetized. IVC was catheterized via the right femoral vein (n = 46) or via the internal jugular vein (n = 3) with a 12.9-F sheath. VenaTech ™ Convertible ™ IVC filters were inserted as either permanent filters (n = 14) or as filters to be converted. Conversion was immediately after deployment (n = 19) or delayed after 1, 3, or 6 months (n = 20). Filter delivery, deployment, and conversion with measurement of migration and tilting were evaluated by cavography. Incorporation of the filter’s stabilizers and arms in the IVC wall was assessed by gross anatomy. Results: Delivery system insertion, filter release, and immediate conversion were successful in all cases. Delayed conversion was completed in all but one sheep, due to insufficient snare tension. Complimentary balloon-catheter inflation was required in 12 of 20 delayed conversions to achieve filter opening. In all 49 sheep, no thrombosis, migration, or significant tilting occurred. Within 4 weeks of conversion, the filter’s stabilizers and arms were incorporated into the IVC wall. Upon removal, the filter head was free of intimal growth. Conclusions: The VenaTech ™ Convertible ™ optional IVC filter was successfully implanted in all sheep with no migration or tilting. Conversion at various dates by filter head removal was feasible in all but one case.

  5. Job Future's Bright for the Chefs of Muskingum Tech.

    Science.gov (United States)

    Hoffman, Carl

    1993-01-01

    A two-year culinary arts program at Muskingum College (Zanesville, Ohio) prepares students for jobs in an emerging service-based economy. Students receive intensive classroom instruction and hands-on learning in a high-tech kitchen. Twenty-five full-time and 12 part-time students are completing their first year in the program. (LP)

  6. CORN, LP Goldfield Approval

    Science.gov (United States)

    This November 19, 2015 letter from EPA approves the petition from CORN, LP, Goldfield facility, regarding non-grandfathered ethanol produced through a dry mill process, qualifying under the Clean Air Act for renewable fuel (D-code 6) RINs under the RFS pro

  7. An unusual cause of an inferior vena cava syndrome

    NARCIS (Netherlands)

    Regoort, M.; Reekers, J. A.; Kromhout, J. G.

    1989-01-01

    Two patients are presented with an occlusion of the infrarenal vena cava caused by a vena cava aneurysm. This rare congenital vena caval anomaly may mimic retroperitoneal lymphadenopathy, especially on CT- imaging without contrast enhancement

  8. Advanced LP turbine blade design

    International Nuclear Information System (INIS)

    Jansen, M.; Pfeiffer, R.; Termuehlen, H.

    1990-01-01

    In the 1960's and early 1970's, the development of steam turbines for the utility industry was mainly influenced by the demand for increasing unit sizes. Nuclear plants in particular, required the design of LP turbines with large annulus areas for substantial mass and volumetric steam flows. Since then the development of more efficient LP turbines became an ongoing challenge. Extensive R and D work was performed in order to build efficient and reliable LP turbines often exposed to severe corrosion, erosion and dynamic excitation conditions. This task led to the introduction of an advanced disk-type rotor design for 1800 rpm LP turbines and the application of a more efficient, reaction-type blading for all steam turbine sections including the first stages of LP turbines. The most recent developments have resulted in an advanced design of large LP turbine blading, typically used in the last three stages of each LP turbine flow section. Development of such blading required detailed knowledge of the three dimensional, largely transonic, flow conditions of saturated steam. Also the precise assessment of blade stressing from dynamic conditions, such as speed and torsional resonance, as well as stochastic and aerodynamic excitation is of extreme importance

  9. LEP dominates LP-HEP

    Energy Technology Data Exchange (ETDEWEB)

    Fraser, Gordon

    1991-09-15

    CERN's LEP electron-positron collider was the star of this year's major physics meeting - the Joint International Lepton-Photon Symposium and Europhysics Conference on High Energy Physics (LP-HEP) - held in Geneva from 25 July - 1 August.

  10. Lp-dual affine surface area

    Science.gov (United States)

    Wei, Wang; Binwu, He

    2008-12-01

    According to the notion of Lp-affine surface area by Lutwak, in this paper, we introduce the concept of Lp-dual affine surface area. Further, we establish the affine isoperimetric inequality and the Blaschke-Santaló inequality for Lp-dual affine surface area. Besides, the dual Brunn-Minkowski inequality for Lp-dual affine surface area is presented.

  11. Anomalies of the vena cava inferior

    International Nuclear Information System (INIS)

    Koen, F.R.; Bouwer, A.J.; Bornman, M.S.; Du Plessis, D.J.

    1986-01-01

    Two cases of anomalous inferior vena cava are presented, with the emphasis on embryology. The firts patient was investigated by venography for a clinically proven varicocele as a probable cause of infertility. A double inferior vena cava was found during venography, and was confirmed by computed tomography (CT). In the second case a left-sided inferior vena cava was an incidental finding when a CT scan was done as a diagnostic procedure in a case of Hodgkin's disease. A short summary of the embryology and the significance of the variants is presented

  12. Persistent left superior vena cava with absent right superior vena cava: image findings

    International Nuclear Information System (INIS)

    Araujo Junior, Cyrillo Rodrigues de; Carvalho, Tarcisio Nunes; Fraguas Filho, Sergio Roberto; Costa, Marlos Augusto Bitencourt; Jacob, Beatriz Mahmud; Machado, Marcio Martins; Teixeira, Kim-Ir-Sen Santos; Ximenes, Carlos Alberto

    2003-01-01

    Persistent left superior vena cava absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the coronary sinus. We report the case of a patient with a persistent left superior vena cava and absence of right superior vena cava identified by chance during a chest radiograph and computed tomography examination for investigation of chronic pulmonary obstructive disease. The patient had no congenital heart disease and the blood from the right side was drained by the persistent left superior vena cava into the right atrium through the coronary sinus. (author)

  13. High-tech entrepreneurship

    DEFF Research Database (Denmark)

    Bernasconi, Michel; Harris, Simon; Mønsted, Mette

    High-tech businesses form a crucial part of entrepreneurial activity - in some ways representing very typical examples of entrepreneurship, yet in some ways representing quite different challenges. The uncertainty in innovation and advanced technology makes it difficult to use conventional economic...... focuses on the blend of theory and practice needed to inform advanced entrepreneurship students of the specifics of high-tech start-ups. Key topics covered include: uncertainty and innovation; entrepreneurial finance; marketing technological innovations; and high-tech incubation management.......Edited by a multi-national team, it draws together leading writers and researchers from across Europe, and is therefore a must-read for all those involved in advanced entrepreneurship with specific interests in high-tech start-ups....

  14. TechEdSat

    Data.gov (United States)

    National Aeronautics and Space Administration — TechEdSat is a 1U CubeSat built by San Jose State University in partnership with NASA Ames Research Center and AAC Microtec. Its mission is to evaluate Space...

  15. Online lektiehjælp

    DEFF Research Database (Denmark)

    Hansen, Jens Jørgen; Remvig, Kirstin

    2016-01-01

    vejledningsdidaktik, herunder metoder, modeller og materialer for lektievejledning i regi af Lektier Online. Lektier Online er en organisation ved Statsbiblioteket i Århus, der tilbyder en online lektiecafe, hvor bl.a. gymnasie-elever kan få hjælp af frivillige universitetsstuderende. Dette didaktiske de-sign er et...

  16. LEP dominates LP-HEP

    International Nuclear Information System (INIS)

    Fraser, Gordon

    1991-01-01

    CERN's LEP electron-positron collider was the star of this year's major physics meeting - the Joint International Lepton-Photon Symposium and Europhysics Conference on High Energy Physics (LP-HEP) - held in Geneva from 25 July - 1 August

  17. High-tech entrepreneurship

    DEFF Research Database (Denmark)

    Bernasconi, Michel; Harris, Simon; Mønsted, Mette

    ; entrepreneurial finance; marketing technological innovations; and high-tech incubation management. Including case studies to give practical insights into genuine business examples, this comprehensive book has a distinctly 'real-world' focus throughout.Edited by a multi-national team, this comprehensive book......High-tech businesses form a crucial part of entrepreneurial activity - in some ways representing very typical examples of entrepreneurship, yet in some ways representing quite different challenges. The uncertainty in innovation and advanced technology makes it difficult to use conventional economic...... planning models, and also means that the management skills used in this area must be more responsive to issues of risk, uncertainty and evaluation than in conventional business opportunities. Whilst entrepreneurial courses do reflect the importance of high-tech businesses, they often lack the resources...

  18. Nalco Fuel Tech

    Energy Technology Data Exchange (ETDEWEB)

    Michalak, S.

    1995-12-31

    The Nalco Fuel Tech with its seat at Naperville (near Chicago), Illinois, is an engineering company working in the field of technology and equipment for environmental protection. A major portion of NALCO products constitute chemical materials and additives used in environmental protection technologies (waste-water treatment plants, water treatment, fuel modifiers, etc.). Basing in part on the experience, laboratories and RD potential of the mother company, the Nalco Fuel Tech Company developed and implemented in the power industry a series of technologies aimed at the reduction of environment-polluting products of fuel combustion. The engineering solution of Nalco Fuel Tech belong to a new generation of environmental protection techniques developed in the USA. They consist in actions focused on the sources of pollutants, i.e., in upgrading the combustion chambers of power engineering plants, e.g., boilers or communal and/or industrial waste combustion units. The Nalco Fuel Tech development and research group cooperates with leading US investigation and research institutes.

  19. Vena cava superior syndrome associated with sarcoidosis

    International Nuclear Information System (INIS)

    Wurm, K.; Walz, M.; Reidemeister, J.C.; Donhuijsen, K.

    1988-01-01

    We report the first observation of clinical manifestations of vena cava superior syndrome (VCSS) associated with sarcoidosis. Twenty-four years after the first signs of the disease had been noted, mediastinal lymphomas penetrating the wall of the vena cava superior caused complete obstruction. It is most unusual for the vessel wall to be destroyed in this way, which explains why VCSS is often missed in sarcoidosis. The obstructed vessel was resected and successfully replaced by a Gore-Tex prosthesis. The importance of VCSS for the differential diagnosis is pointed out. Two further peculiarities are the simultaneous occurrence of elevated intraocular pressure and VCSS, and the familial incidence. (orig.) [de

  20. West Africa LP gas market development study

    International Nuclear Information System (INIS)

    2001-01-01

    Jointly sponsored with the World Bank, this essential study explores the opportunity for greatly expanded LP Gas use in the West Africa region. LP Gas supply in the area is increasing rapidly, This offers the opportunity for bringing modern energy to millions without current access, protects forests the only current source of energy for many, and encourages governments to adopt proactive policies that will reap benefits of the increasing availability of LP Gas. (author)

  1. Lp-mixed affine surface area

    Science.gov (United States)

    Wang, Weidong; Leng, Gangsong

    2007-11-01

    According to the three notions of mixed affine surface area, Lp-affine surface area and Lp-mixed affine surface area proposed by Lutwak, in this article, we give the concept of ith Lp-mixed affine surface area such that the first and second notions of Lutwak are its special cases. Further, some Lutwak's results are extended associated with this concept. Besides, applying this concept, we establish an inequality for the volumes and dual quermassintegrals of a class of star bodies.

  2. Experience with three percutaneous vena cava filters

    International Nuclear Information System (INIS)

    McCowan, T.C.; Ferris, E.J.; Harshfield, D.L.; Hassell, D.R.; Baker, M.L.

    1987-01-01

    Twenty-one Kimray-Greenfield, 33 bird's nest, and 19 Amplatz vena cava filters were placed percutaneously. The Kimray-Greenfield filter was the most difficult to insert. The major problem was the insertion site, which required venipuncture with a 24-F catheter. Minor hemorrhage was frequent, and femoral vein thrombosis occurred in four patients. No migration, caval thrombosis, or pulmonary emboli were seen after Kimray-Greenfield filter placement. The bird's nest filter was relatively easy to insert, although in two cases the filter prongs could not be adequately seated in the wall of the inferior vena cava. Three patients with bird's nest filters had thrombosis below the filter, and three filters migrated to the heart. One migrated filter could not be removed. One patient had multiple small pulmonary emboli at autopsy. No other pulmonary emboli after filter placement were noted. The Amplatz filter was the easiest of the three filters to insert. Only one patient with an Amplatz filter had thrombosis of the vena cava below the filter. No filter migrations were documented, and no recurrent pulmonary emboli were found on clinical or radiologic follow-up. The Amplatz vena cava filter is easier to place than percutaneous Kimray-Greenfield or bird's nest filters, has a low complication rate, and has proven to be clinically effective in preventing pulmonary emboli

  3. Some Inequalities for the Lp-Curvature Image

    Directory of Open Access Journals (Sweden)

    Xiang Yu

    2009-01-01

    Full Text Available Lutwak introduced the notion of Lp-curvature image and proved an inequality for the volumes of convex body and its Lp-curvature image. In this paper, we first give an monotonic property of Lp-curvature image. Further, we establish two inequalities for the Lp-curvature image and its polar, respectively. Finally, an inequality for the volumes of Lp-projection body and Lp-curvature image is obtained.

  4. Total laparoscopic retrieval of inferior vena cava filter.

    Science.gov (United States)

    Benrashid, Ehsan; Adkar, Shaunak Sanjay; Bennett, Kyla Megan; Zani, Sabino; Cox, Mitchell Wayne

    2015-01-01

    While there is some local variability in the use of inferior vena cava filters and there has been some evolution in the indications for filter placement over time, inferior vena cava filters remain a standard option for pulmonary embolism prophylaxis. Indications are clear in certain subpopulations of patients, particularly those with deep venous thrombosis and absolute contraindications to anticoagulation. There are, however, a variety of reported inferior vena cava filter complications in the short and long term, making retrieval of the filter desirable in most cases. Here, we present the case of a morbidly obese patient complaining of chronic abdominal pain after inferior vena cava filter placement and malposition of the filter with extensive protrusion outside the inferior vena cava. She underwent successful laparoscopic retrieval of her malpositioned inferior vena cava filters after failure of a conventional endovascular approach.

  5. Total laparoscopic retrieval of inferior vena cava filter

    Directory of Open Access Journals (Sweden)

    Ehsan Benrashid

    2015-08-01

    Full Text Available While there is some local variability in the use of inferior vena cava filters and there has been some evolution in the indications for filter placement over time, inferior vena cava filters remain a standard option for pulmonary embolism prophylaxis. Indications are clear in certain subpopulations of patients, particularly those with deep venous thrombosis and absolute contraindications to anticoagulation. There are, however, a variety of reported inferior vena cava filter complications in the short and long term, making retrieval of the filter desirable in most cases. Here, we present the case of a morbidly obese patient complaining of chronic abdominal pain after inferior vena cava filter placement and malposition of the filter with extensive protrusion outside the inferior vena cava. She underwent successful laparoscopic retrieval of her malpositioned inferior vena cava filters after failure of a conventional endovascular approach.

  6. Retroperitoneal arteriovenous malformation extending through the inferior vena cava into the heart and causing inferior vena cava dissection

    International Nuclear Information System (INIS)

    Sung, Yon Mi; Choe, Yeon Hyeon; Park, Seung Woo; Park, Pyo Won; Sung, Chang Ohk

    2005-01-01

    We present a case of retroperitoneal arteriovenous malformation extending through the inferior vena cava into the heart, which was associated with dissection of the inferior vena cava in a 32-year-old female. Computed tomography and magnetic resonance imaging showed a double-lumen inferior vena cava and a rod-like solid component attached to a sac-like lesion in the right heart chambers. Digital subtraction angiography showed an arteriovenous malformation draining to the inner lumen of the inferior vena cava. (orig.)

  7. New Tech, New Ties:

    DEFF Research Database (Denmark)

    Ling, Richard

    regardless of where they are. But when we are engaged in these intimate conversations with absent friends, what happens to our relationship with the people who are actually in the same room with us? In New Tech, New Ties, Rich Ling examines how the mobile telephone affects both kinds of interactions......The message of this book is simple: the mobile phone strengthens social bonds among family and friends. With a traditional land-line telephone, we place calls to a location and ask hopefully if someone is "there"; with a mobile phone, we have instant and perpetual access to friends and family......—those mediated by mobile communication and those that are face to face. Ling finds that through the use of various social rituals the mobile telephone strengthens social ties within the circle of friends and family—sometimes at the expense of interaction with those who are physically present—and creates what he...

  8. Vessel wall reaction after vena cava filter placement

    NARCIS (Netherlands)

    Hoekstra, A; Elstrodt, JM; Nikkels, PGJ; Tiebosch, ATMG

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in a porcine model. Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava (IVC) diameter and filter patency, filter leg span, and stability were

  9. Topography and distribution of ostia venae hepatica in the ...

    African Journals Online (AJOL)

    BACKGROUND: Openings of hepatic veins into the retrohepatic surface of the inferior vena cava. (ostia venae hepatica) play a part in controlling hepatic circulation by acting as collateral channels in obstruction. Their topography and distribution must be taken into account during catheterization and liver transplantation.

  10. Fatal pericardial tamponade after superior vena cava stenting.

    NARCIS (Netherlands)

    Ploegmakers, M.J.M.; Rutten, M.J.C.M.

    2009-01-01

    We discuss a fatal complication of percutaneous superior vena cava (SVC) self-expandable stent placement in a patient with superior vena cava syndrome (SVCS). The SVCS was caused by a malignant mediastinal mass with total occlusion of the SVC. Twenty-four hours after the procedure, the patient died

  11. Ultrasound Detection of Superior Vena Cava Thrombus

    Directory of Open Access Journals (Sweden)

    Aaron Birch

    2014-09-01

    Full Text Available Superior vena cava (SVC syndrome is most commonly the insidious result of decreased vascular flow through the SVC due to malignancy, spontaneous thrombus, infections, and iatrogenic etiologies. Clinical suspicion usually leads to computed tomography to confirm the diagnosis. However, when a patient in respiratory distress requires emergent airway management, travel outside the emergency department is not ideal. With the growing implementation of point-of-care ultrasound (POCUS, clinicians may make critical diagnoses rapidly and safely. We present a case of SVC syndrome due to extensive thrombosis of the deep venous system cephalad to the SVC diagnosed by POCUS. [West J Emerg Med. 2014;15(6:715-718

  12. FinTech in Denmark

    OpenAIRE

    Hategan, Ramona Anamaria; Mockus, Gytis; Trinkunaite, Sarune

    2017-01-01

    ABSTRACTThe purpose of this paper has been to seek understanding and knowledge of FinTech phenomenon, with a particular focus on the effect of its emergence on the Danish financial sector. We have attempted to answer our initial research question with the help of a theoretical and methodological framework conceived of concepts belonging to Actor-Network Theory, Diffusion of Innovation Theory and alluding to Foucault’s concepts of power, knowledge and discourses. We have followed FinTech as an...

  13. Endovascular management of inferior vena cava filter thrombotic occlusion.

    Science.gov (United States)

    Branco, Bernardino C; Montero-Baker, Miguel F; Espinoza, Eduardo; Gamero, Maria; Zea-Vera, Rodrigo; Labropoulos, Nicos; Leon, Luis R

    2018-01-01

    Objective Inferior vena cava occlusion is a potentially life-threatening complication related to caval filters. We present our experience with filter-induced inferior vena cava occlusion in order to assess the feasibility, safety, and effectiveness of endovascular management. Methods A retrospective review of all patients undergoing inferior vena cava filter placement over a 60-month study period was performed. From this cohort, a total of 10 cases of inferior vena cava occlusion after filter placement were identified. Demographics, clinical data, procedures, and outcomes were extracted. Patients were followed to the last clinic visit or until they died. Results One-hundred eighty filters were placed by our group practice during the study period. Of those, a total of 10 patients were identified. Overall, there were 7 males; the mean age was 57.1 years (25-78 years). The median time between inferior vena cava filter placement and filter occlusion was 105 days (range 5-4745 days). All patients were clinically symptomatic at the time of their presentation. Nine out of 10 patients were successfully managed endovascularly. Trellis™-8 thrombectomy was the most common endovascular strategy performed ( n = 9). Four patients had balloon angioplasty, two of those with stent placement for chronically occluded inferior vena cava/iliac veins. No thromboembolic complications developed during a median follow-up period of 233 days (range 4-1083 days). Conclusions Endovascular management of inferior vena cava occlusion is feasible, safe, and effective in decreasing thrombus burden in the presence of an inferior vena cava filter. Further studies evaluating long-term inferior vena cava patency and optimal surveillance regimen after endovascular management of filter-related inferior vena cava occlusion are warranted.

  14. The clinical application of inferior vena caval CO2-DSA

    International Nuclear Information System (INIS)

    Guo Jinhe; Teng Gaojun; Zhu Guangyu; Li Guozhao; Fang Wen; He Shicheng; Deng Tang

    2007-01-01

    Objective: To explore the feasibility and safety of inferior vena caval CO 2 -DSA and evaluate the results of inferior vena cavography using CO 2 -DSA or iodinated contrast media. Methods: 25 patients diagnosed as deep venous thrombosis of lower limb were prepared to conceive the implantation of inferior vena caval filter. The inferior vena cava and right renal vein CO 2 -DSA and iodinated contrast media DSA were carried out through jugular or femoral vein approach in all patients. Results: The inferior vena caval angiography with CO 2 -DSA or iodinated contrast media were carried out successfully in all patients. The quality of the inferior vena caval angiogram showed: with CO 2 as contrast media, 14 cases obtained excellent images and 11 cases had good images; with iodinated contrast media the images of 18 cases were excellent and 7 cases were good. No thrombus and variation of inferior vena cava were found by the two kinds of angiography. The diameter of inferior vena cava showed: (20.01 ± 0.83) mm with CO 2 contrast media and (20.15 ± 0.92) mm with iodinated contrast media, (P=0.006); having statistical significance between them. The safety of angiography with CO 2 presented only 1 case with transient slight decrease of O 2 saturation. No abnormal changes were found in blood pressure, heart rate and so on. Conclusions: Inferior vena caval CO 2 -DSA is feasible and safe, with statistical significance in the measurement of inferior vena caval diameter comparing with iodinated contrast material but with no influence on the implantation of filter. (authors)

  15. Tomographic anatomy of the vena cava and renal veins: features relevant to vena cava filter placement

    Directory of Open Access Journals (Sweden)

    Thiago Melo do Espírito Santo

    2015-03-01

    Full Text Available BACKGROUND: There is a growing demand for invasive procedures involving the inferior vena cava, in particular for placement of vena cava filters. It is not always easy to identify the more distal renal vein with cavography, for safe release of filters. OBJECTIVES: To determine parameters for the relationships between the renal veins and the infrarenal vena cava and their corresponding vertebral bodies, their relationships with biotype and the occurrence of anatomic variations, the relationships between vertebral bodies and the bifurcation of the common iliac veins and the distance from this bifurcation to the outflow of the more distal renal vein, with reference to placement of vena cava filters. METHODS: A total of 150 abdominal computed tomography scans conducted from October to November 2011 were analyzed and classified according to the biotype exhibited (using Charpy's angle. Scans were performed at MEDIMAGEM and analyzed at the Integrated Vascular Surgery Service, both part of Hospital da Beneficência Portuguesa in São Paulo, Brazil. RESULTS: In 127 of the 150 scans analyzed (84.66%, the more distal renal vein emerged between the first lumbar intervertebral space (L1-L2 and the body of L2, irrespective of patient biotype. Just 23 patients (15.33% exhibited a more distal renal vein with outflow below the body of L2, i.e. in the projection of the space between L2 and L3. CONCLUSIONS: The radiological correlation between the confluence of the more distal renal vein and vertebral bodies exhibits little variation, irrespective of the biotype of the patient.

  16. Right superior vena cava draining into the left atrium

    Energy Technology Data Exchange (ETDEWEB)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); Batisse, Alain [Institut de Puericulture et de Perinatalogie, Paris (France); Vouhe, Pascal [University Rene Descartes-Paris 5, Department of Paediatric Cardiac Surgery, Hopital Necker-Enfants Malades, Paris (France); Ou, Phalla [University Rene Descartes-Paris 5, Department of Paediatric Cardiology, Hopital Necker-Enfants Malades, Paris (France); University Rene Descartes-Paris 5, Department of Pediatric Radiology, Hopital Necker-Enfants Malades, Paris (France)

    2008-08-15

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  17. Right superior vena cava draining into the left atrium

    International Nuclear Information System (INIS)

    Calcagni, Giulio; Sidi, Daniel; Bonnet, Damien; Batisse, Alain; Vouhe, Pascal; Ou, Phalla

    2008-01-01

    The right superior vena cava draining into the left atrium is a rare malformation causing cyanosis and clubbing in patients in whom no other signs of congenital heart defect are present. Diagnosis may be difficult as cyanosis may be mild and the anomaly is not always easily detectable by echocardiography. For this reason we report a 13-month-old male in whom we confirmed the clinical and echocardiographic suspicion of anomalous drainage of the right superior vena cava using multidetector CT. This allowed successful surgical reconnection of the right superior vena cava to the right atrium. (orig.)

  18. Statistical review of global LP gas 2001

    International Nuclear Information System (INIS)

    2001-01-01

    This review provides essential production and consumption data from 1990 through 2000. A more detailed breakdown of supply and sector demand is given for the year 2000 and historic data on international trade, shipping and pricing is also shown. Statistics pertaining to auto-gas are also included in this edition of Statistical Review of Global LP Gas 2001. (author)

  19. Statistical Review of Global LP Gas 2002

    International Nuclear Information System (INIS)

    2002-01-01

    This review provides essential production and consumption data from 1991 through 2001. A detailed breakdown of supply and sector demand is given for the year 2001 and historic data on international trade, shipping and pricing is also shown. Statistics pertaining to auto-gas are also included in this edition of Statistical Review of Global LP Gas 2001. (author)

  20. Radiotherapy of superior vena cava syndrome

    International Nuclear Information System (INIS)

    Kawanami, Shoko; Imada, Hajime; Terashima, Hiromi; Nakata, Hajime

    1996-01-01

    The records of 38 patients with superior vena cava syndrome (SVC syndrome) due to malignancy and who received radiation therapy were retrospectively reviewed. The majority were lung cancers, constituting 28 of the 38 cases (73.7%). All patients were treated with conventional radiation doses ranging from 20 to 70 Gy and good symptomatic response was observed in 31 cases (81.6% ). The response appeared within 1.7±0.9 weeks on average (3 days-4 weeks;, and performance status also improved in 50% of the patients. The median survival was 6.6 months. Long term survivors were seen mostly in patients with thymoma, and only one patient ever showed a recurrence of SVC syndrome. We conclude that radiotherapy can be an effective therapeutic modality for SVC syndrome and that it improves the quality of life in most patients. (author)

  1. Collateral circulations in inferior vena cava obstruction

    International Nuclear Information System (INIS)

    Lee, Jong Beum; Park, Jae Hyung; Han, Man Chung; Park, Soo Soung

    1985-01-01

    Obstruction of the inferior vena cava (IVC) is an uncommon condition, and the collateral pathway varies according to the level, extent, duration and the cause of obstruction. Membranous obstruction of IVC in its hepatic portion might be one of the principle cause among Korean, though not reported till now. Analytical study was performed in 26 cases of IVC obstruction with various cause. 1. The level of the obstruction showed relatively even distribution as follows, upper caval in 11 cases, middle caval in 6 cases and infrarenal in 9 cases. 2. The main cause of upper caval obstruction was membranous obstruction. 3. As a whole, the main collateral pathway was the central route (22 cases: 85%). 4. Characteristic collateral pathway unique to upper caval obstruction was transhepatic venous collateral, developed between the obstructed segment and unobstructed segment of IVC. 5. Scalloping of left cardiac border produced by pericardiophrenic venous collateral was characteristic simple chest x-ray finding in IVC obstruction

  2. CT findings of superior vena cava syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee [Catholic Medical College, Seoul (Korea, Republic of)

    1986-10-15

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%)

  3. CT findings of superior vena cava syndrome

    International Nuclear Information System (INIS)

    Lim, Jun; Lee, Jae Mun; Kim, Choon Yul; Bahk, Yong Whee

    1986-01-01

    Since early 1980's high resolution CT has been used for detection of intrathoracic pathologic condition such as superior vena cava syndrome. Authors retrospectively analysed CT findings of 18 cases of proven SVC syndrome. The results were as follows: 1. The mean age was 50-year-old, and 14 cases were male. 2. Of 18 cases of SVC syndrome, 8 cases had confirmed to be lung cancers, malignant thymoma and teratoma were respectively each 2 cases, and malignant lymphoma, mediastinal abscess, thyroid adenoma and metastatic tumor were 1 case. 3. CT findings were A. Abnormal SVC consisted of compression with displacement (44.4%), intraluminal thrombus (27.8%), and encasement (27.8%). B. The collateral pathways were the azygos-homozygous (88.8%), vertebral (50%), internal mammary (44.4%), and lateral thoracic route (33.3%).

  4. Inferior vena cava obstruction and shock

    Directory of Open Access Journals (Sweden)

    Megri Mohammed

    2018-01-01

    Full Text Available Shock is one of the most challenging life-threatening conditions with high mortality and morbidity; the outcomes are highly dependent on the early detection and management of the condition. Septic shock is the most common type of shock in the Intensive Care Unit. While not as common as other subsets of shock, obstructive shock is a significant subtype due to well defined mechanical and pathological causes, including tension pneumothorax, massive pulmonary embolism, and cardiac tamponade. We are presenting a patient with obstructive shock due to inferior vena cava obstruction secondary to extensive deep venous thrombosis. Chance of survival from obstructive shock in our patient was small; however, there was complete and immediate recovery after treatment of the obstruction on recognizing the affected vessels. This case alerts the practicing intensivist and the emergency medicine physician to consider occlusion of the great vessels other than the pulmonary artery or aorta as causes of obstructive shock.

  5. Superior vena thrombosis with peripartum dilated cardiomyopathy

    International Nuclear Information System (INIS)

    Munir, R.; Hussain, S.; Kayani, A.M.

    2014-01-01

    A 30 years multiparous female with history of emergency caesarean section 10 days back was referred to us with cough, severe breathlessness at rest, orthopnea with pain in neck and arms. Clinical examination revealed signs of heart failure. Echocardiography showed ejection fraction of 15%, with no right ventricular strain. A diagnosis of peripartum cardiomyopathy was made. Doppler ultrasound of neck veins showed bilateral internal jugular vein thrombosis. Subsequent multislice CT examination showed thrombosis of superior vena cava and both internal jugular veins (with collateral formation) and pulmonary embolism. There were no mediastinal abnormalities on the CT scan. Her thrombophilia screen and CT scan brain was normal. She was managed in collaboration with cardiologist. Following treatment with subcutaneous enoxaparin therapy and warfarin her symptoms of upper limb pain improved. She responded very well to medical therapy for heart failure with marked improvement of NYHA functional class. (author)

  6. Superior vena cava syndrome in hemodialysis patient

    Directory of Open Access Journals (Sweden)

    Azeb Molhem

    2011-01-01

    Full Text Available Obstruction of blood flow in the superior vena cava (SVC results in symptoms and signs of SVC syndrome. SVC obstruction can be caused either by invasion or external compression of the SVC by contagious pathologic processes involving the right lung, lymph nodes, and other mediastinal structures, or by thrombosis of blood within the SVC. Occasionally, both mechanisms co-exist. We hereby report a case of a 28-year-old male, Saudi patient who was diagnosed with end-stage renal disease and was maintained on regular hemodiaysis via right jugular vein dual lumen catheter for ten months. Three years later, the patient presented with signs and symptoms suggestive of SVC obstruction that was successfully managed with SVC stenting.

  7. High Tech M&As

    DEFF Research Database (Denmark)

    Toppenberg, Gustav

    2013-01-01

    Technology driven industries have seen fast moving technology changes, higher complexity and reduced product life cycles. These emerging trends present challenges for companies in industries where technology is at the forefront. The extant research deals with ‘low-tech’ industries and majority...... of findings are not applicable to the high-tech industry; in fact this industry has many additional challenges. In this study, we aim to explore the process of M&A in the high-tech industry by drawing on extant literature and empirical field work. The paper outlines a research project in progress which...... intends to provide theoretical, empirical and practical contributions in answering the research question: what role does Operations and IT play in creating value in high-tech M&As? The research adds a needed perspective on M&A literature by unveiling unique challenges and opportunities faced by the M...

  8. Symplastic Leiomyoma in the Suprarenal Inferior Vena Cava

    International Nuclear Information System (INIS)

    Kahveci, Volkan; Ogur, Torel; Cipe, Gokhan; Ozdemir, Sevim; Hazinedaroglu, Selcuk

    2012-01-01

    Leiomyomas are benign tumors of the soft tissue and may develop in any location where smooth muscle is present. Leiomyoma in the inferior vena cava is a rarely seen pathology, and symplastic leiomyoma is also a rare histological variant of leiomyoma. In this case, we present a rare histological variant of symplastic leiomyoma in the inferior vena cava (IVC). This is the first radiologically reported case of a symplastic leiomyoma of the IVC

  9. High-Tech Security Help.

    Science.gov (United States)

    Flanigan, Robin L.

    2000-01-01

    Advocates embrace high-tech security measures as necessary to avoid Columbine-style massacres. Critics contend that school systems can go overboard, making students feel less safe and too closely scrutinized. Current electronic, biometric, and computer-mapping devices and school applications are discussed. Vendors are listed. (MLH)

  10. 75 FR 39680 - Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid...

    Science.gov (United States)

    2010-07-12

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR10-44-000; Docket No. PR10-46-000; Docket No. PR10-48- 000; Docket No. PR10-49-000; Docket No. PR10-50-000] Houston Pipe Line Company LP, Worsham-Steed Gas Storage, L.P., Energy Transfer Fuel, LP, Mid Continent Market Center, L.L.C...

  11. Policy subjects of the LP gas industry; LP gas sangyo no seisaku kadai

    Energy Technology Data Exchange (ETDEWEB)

    Murata, K. [Agency of Natural Resources and Energy, Tokyo (Japan)

    1996-09-01

    The paper commented on current environmental changes in the LP gas industry and the measures for reinforcement of the physical constitution. When correction of the high cost structure in Japan is now the problem, waves of deregulation and rationalization reach to not only to LP gas but energy competitive with LP gas such as petroleum, electric power and town gas. With this, it is expected that LP gas will be faced with severe competition with other energy media. In the LP gas industry, business becomes more and more in number and smaller and smaller in scale as it extends downstream. Therefore, the resulting complicatedness in the distribution sector is the problem. It is necessary to realize scale profit in each distribution stage and to heighten productivity by expanding the scale in the retailing stage, especially. It is also important to tackle scale merit, improvement of productivity, and cost reduction by concentrating functions on either of wholesalers or retailers in every function of delivery, safety, free from each distribution stage.

  12. 'Pseudothrombus' of the inferior vena cava

    International Nuclear Information System (INIS)

    Takebayashi, Shigeo; Odagiri, Kunio; Matsui, Kengo; Hayano, Ikuo.

    1983-01-01

    Normal Inferior Vena Cava (IVC) of 15 cases were studies on CT with bolus injection in the foot vein.FWell dilated IVC were obtained on scan both at full-inspiration and full-expiration. As the normal findings of IVC, different opacification patterns which may be designate ''homogenous'', ''layered'' and ''pseudothrombus'' were obtained. The ''homogenous'' opacification was noted both at full-inspiration and full-expiration. In homogenous patterns as noted as ''layered'' and ''pseudothrombus'' were suspected to occur in the case of insufficient mixing of contrast agent with blood and/or insufficient amount of contrast agent. And both these patterns were observed in dilated IVC. The ''layered'' opacified IVC was shown on scan at full-inspiration at which respiratory phase the blood flow in IVC may decrease.FThe ''pseudothrombus'' pattern was generally noted at full-expiration at which the blood flow may increase.FAlthough bolus injection of contrast agent into foot vein is useful for evaluation of IVC, one shound be aware of normal opacification of IVC including ''pseudothrombus'' pattern. (author)

  13. Symptomatic duodenal perforation by inferior vena cava filter.

    Science.gov (United States)

    Baptista Sincos, Anna Pw; Sincos, Igor R; Labropoulos, Nicos; Donegá, Bruno C; Klepacz, Andrea; Aun, Ricardo

    2017-01-01

    Objectives Duodenal perforation by an inferior vena cava filter is rare and life threatening. Our objective is to find out number of occurrences and compare diagnosis and treatments. Method The reference list of Malgor's review in 2012 was considered as well as all new articles with eligible features. Search was conducted on specific databases: MEDLINE, Web of Sciences, and Literatura Latino-Americana e do Caribe em Ciências da Saúde. Results Most of the patients presented with upper abdominal pain and the use of radiologic studies was crucial for diagnosis. The most common treatment was laparotomy with filter or strut removal plus duodenum repair. However, clinical conditions of patients must be considered and the endovascular technique with endograft deployment into inferior vena cava may be an alternative. Conclusion Duodenal perforation by an inferior vena cava filter is uncommon and in high-risk surgical patients endovascular repair must be considered.

  14. PuLP/XtraPuLP : Partitioning Tools for Extreme-Scale Graphs

    Energy Technology Data Exchange (ETDEWEB)

    2017-09-21

    PuLP/XtraPulp is software for partitioning graphs from several real-world problems. Graphs occur in several places in real world from road networks, social networks and scientific simulations. For efficient parallel processing these graphs have to be partitioned (split) with respect to metrics such as computation and communication costs. Our software allows such partitioning for massive graphs.

  15. Superior vena caval obstruction - decompression with chemotherapy and subsequent irradiation

    International Nuclear Information System (INIS)

    Kolaric, K.; Maricic, Z.; Dujmovic, I.; Mrsic, Z.

    1975-01-01

    The clinical picture, pathogenesis and etiology of malignant vena caval obstruction are described. The importance of using modern methods to treat this critical condition is emphasized. Furthermore, the authors examine the principles of chemotherapeutic decompression followed by irradiation. A single dose of nitrogen mustard was applied intravenously, followed by irradiation, on 24 patients with malignant vena caval obstruction. The results of this treatment are presented. The effect of this treatment was controlled by measuring the venous blood pressure and with chest X-rays. The authors conclude, that this method of decompression is successful in the palliative treatment of this syndrom. (orig.) [de

  16. Liver trauma and transection of the inferior vena cava

    International Nuclear Information System (INIS)

    Radin, D.R.

    1992-01-01

    CT of a child with severe liver trauma due to a seat belt injury demonstrated avulsion of a portion of the lateral segment of the left lobe of the liver. The location of nondependent extravasated contrast material aided in identification of the visceral fracture site (the sentinel contrast sign). Associated transection of the inferior vena cava was evidenced by hypoatenuating zones adjacent to all the major hepatic veins and vena cava (hepatic perivenous tracking). Recognition of these two signs is important so that the radiologist can help the surgeon select the optimal operative approach. (orig.)

  17. Superior and inferior vena cavae: Embryology, variants, and pathology

    International Nuclear Information System (INIS)

    Mendelson, D.S.; Mitty, H.; Janus, C.; Gendal, E.; Berson, B.

    1987-01-01

    The superior and inferior venae cavae may be involved in a host of disease processes. Knowledge of the normal anatomy and variants of these structures is valuable in interpreting plain films and the results of angiographic procedures and all cross-sectional modalities. The authors review the embryology of venae cavae and proceed to describe their normal anatomy and variants. An awareness of the variants can prevent mistaking variants for pathologic processes. Finally, the authors describe pathology involving these vessels and demonstrate the radiographic manifestations

  18. Nederland krijgt belangstelling voor mid tech en low tech kassenbouw (interview met Anne Elings)

    NARCIS (Netherlands)

    Kierkels, T.; Elings, A.

    2013-01-01

    Nederland zet de toon in high tech kassenbouw over de hele wereld. Maar in toenemende mate kijken de toeleveringsbedrijven ook naar mogelijkheden binnen het mid tech en zelfs het low tech segment. De Nederlandse overheid ondersteunt demonstratieprojecten in bijvoorbeeld Mexico, Oost-Afrika en

  19. Running-gear Tech 2001; Fahrwerk-Tech 2001. Tagung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Dynamic driving characteristics, active safety and high comfort are conflicting goals which can be combined by active vehicle management systems. The conference discussed modern tools and methods in the fields of design, simulation and experiment. [German] Im Zielkonflikt zwischen Fahrdynamik, aktiver Sicherheit und Komfort bieten Fahrzeugregelsysteme enorme Moeglichkeiten. Systeme fuer Bremsen, Stabilisierung, Daempfung, Aufbaukontrolle und Fahrerassistenz werden in der Zukunft zu einem Fahrwerksmanagement verschmelzen. Diese Fahrzeugintelligenz erfordert moderne Tools und Methoden im Bereich Konzeption, Simulation und Versuch. Die Tagung Fahrwerk-Tech 2001 wird das Fahrwerk in dieser Gesamtheit betrachten und Experten aus den verschiedenen Bereichen zusammen bringen. (orig.)

  20. Bilateral inferior vena cava filter insertion in a patient with duplication of the infrarenal vena cava.

    LENUS (Irish Health Repository)

    Leong, S

    2010-06-19

    BACKGROUND: Inferior vena cava (IVC) filter insertion is a commonly performed procedure for indications such as recurrent pulmonary emboli or contraindication to anticoagulation. Symptomatic duplication of the IVC is exceedingly rare with only a handful of cases being described in the literature. AIM: We report an unusual case of a patient with symptomatic duplication of the IVC. RESULT: A 53-year-old woman presented at our hospital for resection of a cerebral metastasis from a non-small cell lung cancer following a recent diagnosis of bilateral lower limb deep venous thrombosis. This required perioperative reversal of anticoagulation and IVC filter insertion. Conventional venography performed during filter insertion documented the existence of a duplicated IVC. CONCLUSION: We present a case of a symptomatic duplication of the IVC requiring filter insertion. We review the developmental anatomy of the IVC along with the diagnostic findings and management strategies available.

  1. Spiral CT in aplasia of the pre-renal inferior vena cava as a cause of phlebothrombosis from the femoral veins to the inferior vena cava; Spiral-CT einer Aplasie der praerenalen Vena cava inferior als Ursache einer Phlebothrombose von den Oberschenkelvenen bis in die Vena cava inferior

    Energy Technology Data Exchange (ETDEWEB)

    Schweiger, U. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Schedel, H. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany); Thiede, U. [Deutsches Herzzentrum Berlin (Germany). Arbeitsgruppe Digitale Bildbearbeitung; Felix, R. [Strahlenklinik und Poliklinik, Universitaetsklinikum Rudolf Virchow, Freie Univ. Berlin (Germany)

    1994-12-31

    The case report focuses on the computed tomography of the thrombotic okklusion of the inferior vena cava, venae iliacae and femorales communes due to congenital interruption of the prerenal inferior vena cava. The embryology of the abnormality was discussed. (orig.) [Deutsch] Anhand einer Fallstudie wurden die Moeglichkeiten der computertomographischen Diagnostik bei einer durch Teilplasie der `praerenalen` Vena cava inferior hervorgerufenen Thrombose der Vv. femorales superficiales et profundae, der grossen Beckenvenen und der Vena cava inferior erlaeutert. In der Diskussion wurde auf die Embryologie der Missbildung eingegangen. (orig.)

  2. Inferior vena cava leiomyosarcoma: vascular reconstruction is not ...

    African Journals Online (AJOL)

    ... vena cava is a rare and aggressive tumor, arising from the smooth muscle cells in the vessel wall. A large complete surgical resection is the essential treatment. The need of vascular reconstruction is not always mandatory. It's above all to understand the place of the reconstruction with artificial vascular patch prosthetics of ...

  3. Prosthetic replacement of the infrahepatic inferior vena cava for leiomyosarcoma.

    Science.gov (United States)

    Illuminati, Giulio; Calio', Francesco G; D'Urso, Antonio; Giacobbi, Daniela; Papaspyropoulos, Vassilios; Ceccanei, Gianluca

    2006-09-01

    Resection of the infrahepatic inferior vena cava associated with prosthetic graft replacement for caval leiomyosarcoma is an acceptable procedure to obtain prolonged and good-quality survival. A consecutive sample clinical study with a mean follow-up of 40 months. The surgical department of an academic tertiary center and an affiliated secondary care center. Eleven patients, with a mean age of 51 years, who have primary leiomyosarcoma of the infrahepatic inferior vena cava. All of the patients underwent radical resection of the tumor en bloc with the affected segment of the vena cava. Reconstruction consisted of 10 cavocaval polytetrafluoroethylene grafts and 1 cavobiliac graft. An associated right nephrectomy was performed in 2 cases. The left renal vein was reimplanted in the graft in 3 cases. Cumulative disease-specific survival, disease-free survival, and graft patency rates expressed by standard life-table analysis. No patients died in the postoperative period. The cumulative (SE) disease-specific survival rate was 53% (21%) at 5 years. The cumulative (SE) disease-free survival rate was 44% (19%) at 5 years. The cumulative (SE) graft patency rate was 67% (22%) at 5 years. Radical resection followed by prosthetic graft reconstruction is a valuable method for treating primary leiomyosarcoma of the infrahepatic inferior vena cava.

  4. Renal Angiomyolipoma Associated with Inferior Vena Cava Thrombus

    Directory of Open Access Journals (Sweden)

    Xavier Durand

    2009-01-01

    Full Text Available A 57-year-old woman was found to have an inferior vena cava involvement of a known sinusal angiomyolipoma incompletely resected three years beforehand. Intravascular extension into the IVC of angiomyolipoma has rarely been reported. We present a new case and reconsider the literature about this uncommon complication of a benign renal tumor.

  5. Asymptomatic Lumbar Vertebral Erosion from Inferior Vena Cava Filter Perforation

    International Nuclear Information System (INIS)

    Fang, Wayne; Hieb, Robert A.; Olson, Eric; Carrera, Guillermo F.

    2007-01-01

    In 2002, a 24-year-old female trauma patient underwent prophylactic inferior vena cava filter placement. Recurrent bouts of renal stones prompted serial CT imaging in 2004. In this brief report, we describe erosion and ossification of the L3 vertebral body by a Greenfield filter strut

  6. Vena porta thrombosis in patient with inherited factor VII deficiency

    DEFF Research Database (Denmark)

    Klovaite, Jolanta; Friis-Hansen, Lennart Jan; Larsen, Fin S

    2010-01-01

    with inherited FVII deficiency and chronic vena porta thrombosis. She presented at 32 weeks of gestation with spontaneously increased international normalized ratio, severe thrombocytopenia and very few unspecific symptoms. The extensive examination of the patient revealed cavernous transformation of the portal...

  7. Superior vena cava obstruction caused by radiation induced venous fibrosis

    NARCIS (Netherlands)

    Van Putten, JWG; Schlosser, NJJ; Vujaskovic, Z; Van der Leest, AHD; Groen, HJM

    Superior vena cava syndrome is most often caused by lung carcinoma. Two cases are described in whom venous obstruction in the superior mediastinum was caused by local vascular fibrosis due to radiotherapy five and seven years earlier. The development of radiation injury to greater vessels is

  8. An urban trauma centre experience with abdominal vena cava injuries

    African Journals Online (AJOL)

    Background: The aim of the study was to present the surgical management of injuries to the abdominal vena cava (AVC) and to identify clinical and physiological factors and management strategies which affect the outcome. Methods: A retrospective review was conducted of AVC injuries in patients attending the trauma ...

  9. 78 FR 45592 - DeltaPoint Capital IV, LP;

    Science.gov (United States)

    2013-07-29

    ..., Suite 160, Pittsford, NY 14534. The financing was contemplated for working capital. The financing is... SMALL BUSINESS ADMINISTRATION [License No. 02/02-0662] DeltaPoint Capital IV, LP; Notice Seeking... given that DeltaPoint Capital IV, L.P., 45 East Avenue, 6th Floor, Rochester, NY 14604, Federal...

  10. Trigonometric bases for matrix weighted Lp-spaces

    DEFF Research Database (Denmark)

    Nielsen, Morten

    2010-01-01

    We give a complete characterization of 2π-periodic matrix weights W for which the vector-valued trigonometric system forms a Schauder basis for the matrix weighted space Lp(T;W). Then trigonometric quasi-greedy bases for Lp(T;W) are considered. Quasi-greedy bases are systems for which the simple...

  11. Flygtninge på langvarig starthjælp

    DEFF Research Database (Denmark)

    Johansen, Adam; Højland, Marianne; Hansen, Henning

    Spørgeskema-, fokusgruppe- og interviewbaseret undersøgelse af personlige og sociale konsekvenser af familiers forsørgelse på starthjælp. Kvalitativ og kvantitativ undersøgelse af starthjælpens konsekvenser for flygtningefamilier med mere end 1 år på starthjælp...

  12. The role of LP gas in eradicating energy poverty

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, Michael; Behuria, Sarthak

    2010-09-15

    LP Gas is an ideal solution for dealing with energy poverty. Clean burning, low carbon, extremely efficient, requiring minimal infrastructure or R and D investment and with plentiful long term global supply, LP Gas can be quickly introduced to play an important role in eradicating energy poverty and steering both industrialised and developing countries onto more sustainable energy development paths.

  13. 76 FR 49760 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2011-08-11

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-524-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on July 29, 2011, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056-5310, filed with the Federal Energy...

  14. 78 FR 66352 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2013-11-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-9-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on October 17, 2013, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed an application in Docket No. CP14-9...

  15. 78 FR 43874 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2013-07-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP13-514-000] Texas Eastern Transmission, LP; Notice of Application On July 2, 2013, Texas Eastern Transmission, LP (Texas Eastern) filed... natural gas facilities no longer in service. As described more fully in the Application, Texas Eastern...

  16. 76 FR 38381 - Texas Eastern Transmission, LP; Notice of Amendment

    Science.gov (United States)

    2011-06-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-67-001] Texas Eastern Transmission, LP; Notice of Amendment Take notice that on June 13, 2011, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed in the above referenced docket an amendment...

  17. 78 FR 79687 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2013-12-31

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-29-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on December 10, 2013 Texas Eastern Transmission, LP (Texas Eastern), at 5400 Westheimer Court, Houston, Texas 77056, filed an application in Docket No. CP14...

  18. 77 FR 26534 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2012-05-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP12-164-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on April 19, 2012, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed in Docket No. CP12-164-000, a request...

  19. 77 FR 20015 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2012-04-03

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP12-88-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on March 19, 2012, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056-5310, filed an application in Docket No...

  20. 76 FR 7833 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2011-02-11

    ...] Texas Eastern Transmission, LP; Notice of Application Take notice that on January 25, 2011, Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed in the above... TEAM 2012 Project. Specifically, Texas Eastern requests: (i) Authorization under NGA sections 7(b) and...

  1. 77 FR 12045 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2012-02-28

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP12-68-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on February 16, 2012, Texas Eastern Transmission, LP (Texas Eastern), PO Box 1642, Houston, Texas 77056 filed an application in the above referenced docket...

  2. Tech Prep Compendium of Models. [Revised].

    Science.gov (United States)

    Delaware Technical and Community Coll., Dover.

    This publication discusses four models for technical preparation (tech prep): program organization; student progress; tech prep data collection and evaluation model; and school/community. The program organization model is divided into four sections. Section I, the business industry, and labor section, shows the flow from craft committee and…

  3. Injuries of the retrohepatic inferior vena cava and the liver

    Directory of Open Access Journals (Sweden)

    Koprivica Radenko

    2008-01-01

    Full Text Available Beckground. Injuries of the retrohepatic inferior vena cava, and the liver have mortality rate up to 71-78%. We presented a patient with combined injury of the retrohepatic inferior vena cava, liver, craniocerebral and thoracic traumas, inflicted in a traffic accident. Case report. Man, 20 years old has been injured in a traffic accident. At admission, 20 minutes after the injury, the patient was comatose and hypotensive. Bloody content was obtained by abdominal tracer. The patient underwent emergent laparotomy, utilizing trifurcated incision and cell saver device. Abdominal exploration revealed two liters of free blood and massive retroperitoneal hematoma. Manual compression of the liver was done, as well as perihepatic packing, complete hepatic vascular exclusion and mobilization of the right liver lobe. Due to impressive chemodynamic instability supraceliac aortic clamping was performed. Upon exposure of the retrohepatic inferior vena cava and right liver lobe, multiple lacerations of retrohepatic inferior vena cava and right hepatic vein, and right hepatic vein avulsion were found. We also identified an injury of VII and VIII segments of the liver (grade V according to the Moore's classification. Nonexpansive hepatoduodenal ligament hematoma and the injury of II and III segments of the liver group II/III according to Moore were found. Venorrhaphy of the inferior vena cava was done in the area of circumference of the right hepatic vein, a portion of which served as autologous vein patch. Continuous prolene 3/0 venorrhaphy of the distal caval laceration was done. Total caval and aorta clamping time of the inferior vena cava was 41 minutes. Atypical resection, debridment, of hepatic segments was done by using a harmonic scalpel. Hepatoduodenal ligament was declamped after 65 minutes. Fibrin glue was applied on the resectioned area of liver. The patient received 3.2 l of autologuos blood transfusion with 5 units of packed red blood cells, 6

  4. Lp-dual affine surface area forms of Busemann–Petty type problems

    Indian Academy of Sciences (India)

    Associated with the notion of Lp-intersection body which was defined ... Lp-dual affine surface area; Lp-intersection body; Busemann–Petty ..... [11] Schneider R, Convex Bodies: The Brunn–Minkowski Theory (1993) (Cambridge: Cam-.

  5. Lithium in LP944-20

    Science.gov (United States)

    Pavlenko, Ya. V.; Jones, H. R. A.; Martín, E. L.; Guenther, E.; Kenworthy, M. A.; Zapatero Osorio, M. R.

    2007-09-01

    We present a new estimate of the lithium abundance in the atmosphere of the brown dwarf LP944-20. Our analysis is based on a self-consistent analysis of low-, intermediate- and high-resolution optical and near-infrared spectra. We obtain logN(Li) = 3.25 +/- 0.25 using fits of our synthetic spectra to the LiI resonance line doublet profiles observed with Very Large Telescope/Ultraviolet-Visual Echelle Spectrograph (VLT/UVES) and Anglo-Australian Telescope/Segmented Pupil/Image Reformatting Array of Lenslets (AAT/SPIRAL). This lithium abundance is over two orders of magnitude larger than previous estimates in the literature. In order to obtain good fits of the resonance lines of KI and RbI and better fits to the TiO molecular absorption around the LiI resonance line, we invoke a semi-empirical model atmosphere with the dusty clouds located above the photosphere. The lithium abundance, however, is not changed by the effects of the dusty clouds. We discuss the implications of our estimate of the lithium abundance in LP944-20 for the understanding of the properties of this benchmark brown dwarf. Based on observations obtained on the European Southern Observatory at Cerro Paranal, Chile, in programs 68.C-0063(A) and 072.C-0110(B), the Anglo-Australian Telescope at Siding Springs Observatory during commissioning observations for SPIRAL (Segmented Pupil/Image Reformatting Array of Lenslets) instrument and the Keck Observatory in Mauna Kea, Hawaii. E-mail: yp@mao.kiev.ua

  6. Mechatronics education at Virginia Tech

    Science.gov (United States)

    Bay, John S.; Saunders, William R.; Reinholtz, Charles F.; Pickett, Peter; Johnston, Lee

    1998-12-01

    The advent of more complex mechatronic systems in industry has introduced new opportunities for entry-level and practicing engineers. Today, a select group of engineers are reaching out to be more knowledgeable in a wide variety of technical areas, both mechanical and electrical. A new curriculum in mechatronics developed at Virginia Tech is starting to bring students from both the mechanical and electrical engineering departments together, providing them wit an integrated perspective on electromechanical technologies and design. The course is cross-listed and team-taught by faculty from both departments. Students from different majors are grouped together throughout the course, each group containing at least one mechanical and one electrical engineering student. This gives group members the ability to learn from one another while working on labs and projects.

  7. Transverse stress induced LP 02-LP 21 modal interference of stimulated Raman scattered light in a few-mode optical fiber

    Science.gov (United States)

    Sharma, A.; Posey, R.

    1996-02-01

    Four-photon mixing followed by stimulated Raman scattering is observed in LP 02 mode in a 7.9 μm core diameter optical fiber. A localized transverse stress efficiency couples LP 02 to the LP 21 mode with a macroscopic beat length of 1.8 mm. LP 02-LP 21 modal interference is investigated by detecting the 550-590 nm SRS through a pinhole in the far field exit plane. Quantitative explanation of wavelength dependent intensity modulation results in a precise experimental determination of {∂[β 02(λ) - β 21(λ)] }/{∂λ}, for mode-propagation constants β02( λ) and β21( λ) of LP 02 and LP 21 modes respectively, as well as Δ, the relative core-cladding refractive index difference. The LP 02-LP 21 modal interference is used for sensing of temperature between 50-300°C.

  8. A new Nitinol stent for use in superior vena cava syndrome

    DEFF Research Database (Denmark)

    Andersen, Poul Erik; Midtgaard, Annette; Brenøe, Anne-Sofie

    2015-01-01

    AIM: The aim of the study was to assess the early clinical experience with the Zilver Vena stent in treating patients with malignant superior vena cava syndrome. METHODS: Demographic, procedural, and follow-up data of 12 patients (seven women; mean age 69 years) treated for superior vena cava...... syndrome with in all 21 Zilver Vena stents between March 2012 and October 2013 were retrospectively reviewed. All cavographies and contrast enhanced CT related to the treatment and during follow-up were evaluated and the patients had clinical follow-up until dead. They were all in terminal state...... at the time of stent deployment. RESULTS: All patients had superior vena cava obstruction and clinical superior vena cava syndrome caused by malignant expansive mediastinal disease (eight patients non-small cell lung cancer and four small cell lung cancer). The technical success with deployment of the stents...

  9. Vessel Wall Reaction after Vena Cava Filter Placement

    International Nuclear Information System (INIS)

    Hoekstra, Arend; Elstrodt, Jan M.; Nikkels, Peter G.J.; Tiebosch, Anton T.M.G.

    2002-01-01

    Purpose: To evaluate the interaction between the Cordis Keeper vena caval filter and vessel wall in aporcine model.Methods: Implantation of the filter was performed in five pigs. Radiologic data concerning inferior vena cava(IVC) diameter and filter patency, filter leg span, and stability were collected. At 2 or 6 months post-implantation, histopathologic analysis of the IVC wall was performed.Results: All filters remained patent with no evidence of migration. However, at 6 months follow-up, two legs of one filter penetrated the vessel wall and were adherent to the liver. These preliminary results suggest that with the observed gradual increase in the filter span, the risk of caval wall penetration increases with time, especially in a relatively small IVC(average diameter 16 mm).Conclusion: The Cordis Keeper filter was well tolerated, but seems to be prone to caval wall penetration in the long term

  10. Recidiva en vena cava inferior de carcinoma suprarrenal

    Directory of Open Access Journals (Sweden)

    Javier Orrit

    2005-01-01

    Full Text Available Paciente de 15 meses sometido a resección de masa suprarrenal derecha. Estudio de extensión negativo e histología de tumor adrenocortical. Dos meses después presenta recidiva tumoral en vena cava inferior (VCI a nivel de venas suprahepáticas que se reseca bajo hipotermia profunda y parada circulatoria (19 min (Fig. 1. Se extrae una masa friable de 25 × 20 mm que ocluye la VCI, sin evidencia de resto tumoral, aunque se considera resección incompleta al estar infiltradas las paredes de VCI. La histología confirma carcinoma suprarrenal (Fig. 2. A los 5 meses sigue quimioterapia sin datos de nueva invasión de VCI.

  11. Partial anomalous pulmonary venous connection to the superior vena cava.

    Science.gov (United States)

    Aramendi, José I; Rey, Estibaliz; Hamzeh, Gadah; Crespo, Alejandro; Luis, Maite; Voces, Roberto

    2011-04-01

    We describe the surgical technique of reimplantation of the right superior pulmonary vein into the left atrium in 2 patients with partial anomalous pulmonary venous connection to the superior vena cava without atrial septal defect. A right axillary minithoracotomy is done through the fourth intercostal space. The pulmonary vein is detached from its origin in the superior vena cava. This is sutured with 6-0 reabsorbable polydioxanone suture (Ethicon, Somerville, NJ). A lateral clamp is applied to the left atrium, and the pulmonary vein is reimplanted. The patient is extubated in the operating room. Neither cardiopulmonary bypass nor blood transfusion was required. It is simple, safe, and reproducible. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  12. Optional inferior vena caval filters: where are we now?

    LENUS (Irish Health Repository)

    Keeling, A N

    2008-08-01

    With the advent of newer optional\\/retrievable inferior vena caval filters, there has been a rise in the number of filters inserted globally. This review article examines the currently available approved optional filter models, outlines the clinical indications for filter insertion and examines the expanding indications. Additionally, the available evidence behind the use of optional filters is reviewed, the issue of anticoagulation is discussed and possible future filter developments are considered.

  13. Myofibroblastic tumor associated to superior vena cava syndrome

    International Nuclear Information System (INIS)

    Ortega Jaramillo, Hector; Durango Gutierrez, Luisa Fernanda; Perez Figueroa, Maria del Pilar

    2005-01-01

    Inflammatory myofibroblastic tumor (IMT) is an uncommon pathological entity of unknown cause, composed of differentiated myofibroblastic cells accompanied by plasma cells, lymphocytes and eosinophils, which involve extrapulmonary and pulmonary tissues. IMT has an unpredictable clinical course, rarely undergoes malignant transformation. Local invasion and involvement of the mediastinum and hiliar structures are unusual manifestations; however; we reports a case of superior vena cava syndrome and IMT

  14. In vivo evaluation of a new vena cava filter

    Directory of Open Access Journals (Sweden)

    Gilberto do Nascimento Galego

    2016-01-01

    Full Text Available Abstract Background Pulmonary embolism is an important cause of cardiovascular death. Inferior vena cava filters have been shown to be effective for prevention of this condition. Objectives To determine the safety, performance and efficacy of a new inferior vena cava filter in an ovine model. Methods BKone1 filters are self-centering with over-the-wire deployment, have three filtering regions and are made from nickel-titanium alloy. Eight of these filters were implanted in 8 sheep. The sheep were divided into 4 groups of two animals (A and B and the number of clots injected differed by group. Two clots were injected in group 2, four in group 3, eight in group 4 and zero clots in group 1. A animals underwent euthanasia soon after the procedure and B animals were observed for 30 days and then euthanized after a control cavography. All inferior vena cavas were processed for histological examination. Clots were prepared in a metal mold, sectioned and then radiopaque markers were inserted. Clot capture was analyzed by identifying the radiopaque marker on fluoroscopy. Results No clot migration was observed during follow-up. Control cavographies showed patent inferior vena cavas. Pathological examination indicated little inflammatory tissue response. All clots were captured in the condition with 2 clots, only one clot was missed in the group injected with 4 clots and in the condition of 8 clots, they were partly captured. Conclusions The filters were deployed safely. There was a reduction in efficacy as the number of blood clots increased.

  15. Detection by means of CT of inferior vena cava filters

    International Nuclear Information System (INIS)

    Zurera Tendero, L.J.; Canis Lopez, M.; Oteros Fernandez, R.; Ramos Gomez, M.; Garcia Revillo, J.; Roman Rios, G.

    1995-01-01

    Vena cava filters are an excellent tool for the prevention of pulmonary embolism (PE) in patients with deep vein thrombosis (DVT) of the lower limbs. However, these devices are not entirely free of complications as thrombi can develop inside them, threatening to occlude them completely. The objective of this report is to study the incidence of thrombosis in vena cava filters, as well as their impact on prognosis. We also mention the importance of CT as an imaging technique in the study of this complication. We present 30 patients in whom different filters were implanted and their prospective follow-up by means of CT over a mean follow-up period of 36 months. Chi-square analysis was used to determine whether there was a significant relationship among the complications encountered (p<0,05), and their course over time was studied by means of Kaplan-Meyer curves. Five cases (16%) of complete thrombosis of the filter were observed among patients in whom the Gunther model had been implanted, yielding an index of probability of complete permeability of the inferior vena cava at 13 months of 82%. Thrombi of different degrees (between 5% and 60%) were also observed inside the filter in ten patients (33%) with Gunther, Simon-Nitional and LGM models. Filter thrombosis was not significantly associated with the onset of recurrent PE or of venous disorders involving lower limbs, the relationship between PE and preimplantation presence of inferior vena cava thrombosis was significant (p<0.01). It was also observed that post implantation anti coagulation did not significantly prevent later onset of filter thrombosis. (Author)

  16. Modeling Flow Past a Tilted Vena Cava Filter

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L

    2009-06-29

    Inferior vena cava filters are medical devices used to prevent pulmonary embolism (PE) from deep vein thrombosis. In particular, retrievable filters are well-suited for patients who are unresponsive to anticoagulation therapy and whose risk of PE decreased with time. The goal of this work is to use computational fluid dynamics to evaluate the flow past an unoccluded and partially occluded Celect inferior vena cava filter. In particular, the hemodynamic response to thrombus volume and filter tilt is examined, and the results are compared with flow conditions that are known to be thrombogenic. A computer model of the filter inside a model vena cava is constructed using high resolution digital photographs and methods of computer aided design. The models are parameterized using the Overture software framework, and a collection of overlapping grids is constructed to discretize the flow domain. The incompressible Navier-Stokes equations are solved, and the characteristics of the flow (i.e., velocity contours and wall shear stresses) are computed. The volume of stagnant and recirculating flow increases with thrombus volume. In addition, as the filter increases tilt, the cava wall adjacent to the tilted filter is subjected to low velocity flow that gives rise to regions of low wall shear stress. The results demonstrate the ease of IVC filter modeling with the Overture software framework. Flow conditions caused by the tilted Celect filter may elevate the risk of intrafilter thrombosis and facilitate vascular remodeling. This latter condition also increases the risk of penetration and potential incorporation of the hook of the filter into the vena caval wall, thereby complicating filter retrieval. Consequently, severe tilt at the time of filter deployment may warrant early clinical intervention.

  17. Virginia Tech honors women in March

    OpenAIRE

    Lazenby, Jenna

    2007-01-01

    Commemorating National Women's History Month in March, the Virginia Tech community will host a variety of informative, educational, and entertaining events and programs that highlight women's diverse experiences and achievements.

  18. Vena caval impalement: an unusual lawn mower injury in a child.

    Science.gov (United States)

    Muńoz-Juárez, M; Drugas, G T; Hallett, J W; Zietlow, S P

    1998-06-01

    Penetrating injury to the vena cava is a potentially life threatening condition that necessitates prompt recognition and immediate treatment. Herein we describe a unique lawn mower-related injury in a 4-year-old boy, resulting in the impalement of the inferior vena cava by a foreign body projectile. Relevant concepts in the management of children with lawn mower injuries are discussed, with emphasis on penetrating injury to the inferior vena cava.

  19. Aneurisma de la vena de Galeno Galen's vein aneurysm

    Directory of Open Access Journals (Sweden)

    Sergio Piloña Ruiz

    2010-09-01

    Full Text Available La malformación arteriovenosa de la vena de Galeno es una enfermedad congénita poco frecuente que se produce a partir de un defecto en la fusión de las venas cerebrales internas y que, debido a la baja resistencia, produce un cuadro de falla cardíaca de alto gasto. Las manifestaciones clínicas son muy variables y dependen de la edad de presentación. El pronóstico depende del tamaño del aneurisma. Se presenta el caso de un recién nacido del sexo masculino, con diagnóstico prenatal de aneurisma de la vena de Galeno y, desde el nacimiento, graves signos de insuficiencia cardíaca congestiva de difícil tratamiento. Se realiza una revisión sobre el tema.Arteriovenous malformation of Galen's vein is an uncommon congenital disease present from a defect in internal cerebral veins fusion and that due to the low resistance, produces a high output heart failure. Clinical manifestations are very variables depending on age of presentation. Prognosis depends on the size of aneurysm. This is the case of a male newborn diagnosed prenatally with Galen's vein aneurysm and from his birth severe signs of congestive heart failure of difficult treatment. A literature review on this subject is made.

  20. Crash-Tech 2001. Conference; Crash-Tech 2001. Tagung

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    Improved active and passive safety of motor vehicles has resulted in a very much improved accident statistics. This conference discussed further optimisations in motor car safety. The harmonisation of test specifications world-wide was gone into, with particular interest in compatibility. Safety specifications resulting from current accident research and new legislation were gone into, and the current state of measuring and technology in crash testing was outlined. [German] Aufgrund der Verbesserungen in der aktiven und passiven Sicherheit von Fahrzeugen weisen die Unfallstatistiken in vielen europaeischen Laendern eine erfreuliche Tendenz auf. Die Tagung wird sich mit den Moeglichkeiten der weiteren Optimierung der Verkehrssicherheit befassen. Die 'Crash-Tech 2001' will sich mit dem Motto 'Sind wir auf dem Weg zum World NCAP?' der Harmonisierung der Testvorschriften unter Einbeziehung der Kompatibilitaet widmen. Dazu werden Anforderungen an die Fahrzeugsicherheit diskutiert, die sich sowohl aus der aktuellen Unfallforschung als auch aus den Vorschriften ergeben. Weiterhin wird der aktuelle Stand der Mess- und Versuchstechnik im Unfallversuch vorgestellt. (orig.)

  1. LP formulation of asymmetric zero-sum stochastic games

    KAUST Repository

    Li, Lichun

    2014-12-15

    This paper provides an efficient linear programming (LP) formulation of asymmetric two player zero-sum stochastic games with finite horizon. In these stochastic games, only one player is informed of the state at each stage, and the transition law is only controlled by the informed player. Compared with the LP formulation of extensive stochastic games whose size grows polynomially with respect to the size of the state and the size of the uninformed player\\'s actions, our proposed LP formulation has its size to be linear with respect to the size of the state and the size of the uninformed player, and hence greatly reduces the computational complexity. A travelling inspector problem is used to demonstrate the efficiency of the proposed LP formulation.

  2. LP formulation of asymmetric zero-sum stochastic games

    KAUST Repository

    Li, Lichun; Shamma, Jeff S.

    2014-01-01

    This paper provides an efficient linear programming (LP) formulation of asymmetric two player zero-sum stochastic games with finite horizon. In these stochastic games, only one player is informed of the state at each stage, and the transition law is only controlled by the informed player. Compared with the LP formulation of extensive stochastic games whose size grows polynomially with respect to the size of the state and the size of the uninformed player's actions, our proposed LP formulation has its size to be linear with respect to the size of the state and the size of the uninformed player, and hence greatly reduces the computational complexity. A travelling inspector problem is used to demonstrate the efficiency of the proposed LP formulation.

  3. 2009 Navy ManTech Project Book

    Science.gov (United States)

    2009-01-01

    build a hybrid laser / GMAW system that combined deep keyhole penetration of laser welding with the high metal deposition rate of GMAW, enabling...committed to the successful outcome of the ManTech project. In addition, this close working relationship between the parties provides ManTech with a longer...the cost and time to build and repair Navy ships. The Center works closely with the Navy’s acquisition community and the shipbuilding industry to

  4. On $L_p$ Affine Surface Area and Curvature Measures

    OpenAIRE

    Zhao, Yiming

    2015-01-01

    The relationship between $L_p$ affine surface area and curvature measures is investigated. As a result, a new representation of the existing notion of $L_p$ affine surface area depending only on curvature measures is derived. Direct proofs of the equivalence between this new representation and those previously known are provided. The proofs show that the new representation is, in a sense, "polar" to that of Lutwak's and "dual" to that of Sch\\"utt & Werner's.

  5. Experimental study of domestic inferior vena cava filter comparative to Antheor temporary vena cava filter in vitro

    International Nuclear Information System (INIS)

    Chen Guoping; Gu Jianping; Lou Wensheng; He Xu; Chen Liang; Su Haobo

    2007-01-01

    Objective: To evaluate clot capturing efficacy and stability of a new domestic designed inferior vena cava filter (DDIVCF) by comparing with Anthem temporary vena cava filter in vitro. Methods: (1)The DDIVCF and Antheor filter were tested in a flow model simulated the inferior vena cava (IVC) with 20 mm and 25 mm in diameter. The swine clots of four sizes were used: 3 mm x 20 mm, 3 mm x 30 mm, 6 mm x 20 mm, 6 mm x 30 mm. The clot capturing capacity was observed in horizontal position. (2) The stability was observed by measuring the comparative moving distance of 6 mm x 30 mm clots after clot trapping. Results: (1) DDIVCF capture rates were 34%, 56%, 82%, 94% and 26%, 38%, 56%, 86% for the 20 mm and 25 mm IVC models of four different sizes clots respectively, comparing with 54%, 64%, 86%, 96% and 38%, 44%, 68%, 90% respectively of Anthem temporary vena cava filter. The capture rates of DDIVCF and Antheor filter showed no significant differences of 3 mm x 30 mm, 6mm x 20 mm and 6 mm x 30 mm clots in 20 mm and 25 mm IVC models (P>0.05). (2) There was a few caudal migration with no significant difference (P>0.05). The filter migration distances were (0.6±0.3) cm and (1.0±0.1) cm respectively in the 20 mm and 25 mm IVC models with most clots of 6 mm x 30 mm were captured, comparing with (0.4±0.1) cm and (0.8 ±0.3) cm respectively for Antheor filter. Conclusions: DDIVCF is a stable and effective filter in an in-vitro model experiment but application in vivo would rather be further evaluated through more animal experiments. (authors)

  6. Determining the group velocity dispersion by field analysis for the LP0X, LP1X, and LP2X mode groups independently of the fiber length: applications to step-index fibers

    DEFF Research Database (Denmark)

    Israelsen, Stine Møller; Usuga Castaneda, Mario A.; Rottwitt, Karsten

    2017-01-01

    By knowing the electric field distribution of a guided mode in an optical fiber, we are able to evaluate the group velocity dispersion in a weakly guiding step-index fiber for a pure mode in the LP0X, LP1X, and LP2X mode groups independently of the fiber length. We demonstrate the method numerica...

  7. Comparison of superior vena caval and inferior vena caval access using a radioisotope technique during normal perfusion and cardiopulmonary resuscitation

    International Nuclear Information System (INIS)

    Dalsey, W.C.; Barsan, W.G.; Joyce, S.M.; Hedges, J.R.; Lukes, S.J.; Doan, L.A.

    1984-01-01

    Recent studies of thoracic pressure changes during external cardiopulmonary resuscitation (CPR) suggest that there may be a significant difference in the rate of delivery of intravenous drugs when they are administered through the extrathoracic inferior vena cava (IVC) rather than the intrathoracic superior vena cava (SVC). Comparison of delivery of a radionuclide given using superior and inferior vena caval access sites was made during normal blood flow and during CPR. Mean times from injection to peak emission count in each ventricle were determined. There were no significant differences between mean peak times for SVC or IVC routes during normal flow or CPR. When peak times were corrected for variations in cardiac output, there were no significant differences between IVC and SVC peak times during normal flow. During CPR, however, mean left ventricular peak time, when corrected for cardiac output, was significantly shorter (P less than .05) when the SVC route was used. The mean time for the counts to reach half the ventricular peak was statistically shorter (P less than .05) in both ventricles with the SVC route during the low flow of CPR. This suggests that during CPR, increased drug dispersion may occur when drugs are infused by the IVC route and thus may modify the anticipated effect of the drug bolus. These results suggest that during CPR, both the cardiac output and the choice of venous access are important variables for drug delivery

  8. NASA Tech Briefs, February 2009

    Science.gov (United States)

    2009-01-01

    Tech Briefs are short announcements of innovations originating from research and development activities of the National Aeronautics and Space Administration. They emphasize information considered likely to be transferable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. Topics covered include: Measuring Low Concentrations of Liquid Water in Soil; The Mars Science Laboratory Touchdown Test Facility; Non-Contact Measurement of Density and Thickness Variation in Dielectric Materials; Compact Microwave Fourier Spectrum Analyzer; InP Heterojunction Bipolar Transistor Amplifiers to 255 GHz; Combinatorial Generation of Test Suites; In-Phase Power-Combined Frequency Tripler at 300 GHz; Electronic System for Preventing Airport Runway Incursions; Smaller but Fully Functional Backshell for Cable Connector; Glove-Box or Desktop Virtual-Reality System; Composite Layer Manufacturing with Fewer Interruptions; Improved Photoresist Coating for Making CNT Field Emitters; A Simplified Diagnostic Method for Elastomer Bond Durability; Complex Multifunctional Polymer/Carbon-Nanotube Composites; Very High Output Thermoelectric Devices Based on ITO Nanocomposites; Reducing Unsteady Loads on a Piggyback Miniature Submarine; Ultrasonic/Sonic Anchor; Grooved Fuel Rings for Nuclear Thermal Rocket Engines; Pulsed Operation of an Ion Accelerator; Autonomous Instrument Placement for Mars Exploration Rovers; Mission and Assets Database; TCP/IP Interface for the Satellite Orbit Analysis Program (SOAP); Trajectory Calculator for Finite-Radius Cutter on a Lathe; Integrated System Health Management Development Toolkit.

  9. THE FUNDAMENTALS OF HIGH-TECH SECTOR AND HIGH-TECH COMPANIES OPERATION

    Directory of Open Access Journals (Sweden)

    Svetlana V. Gavrilova

    2014-01-01

    Full Text Available The article develops the concept of the«high-tech sector» and the «high-techcompany» as well as their differences and relation. Further the author accounts for the particularities of the high-tech company functioning compared to the common one. Finally the key factors and coreelements of high technology are identified.

  10. High tech in the Öresund region

    DEFF Research Database (Denmark)

    Hansen, Povl Adler; Serin, Göran Folke

    This book discusses the development conditions in the high tech sector for both high tech manufacturing and services. A central issue in the book is the differences in externalities which exist between various industries in the high tech sector. In this connection the confusion of externalities...... related to different parts of the high tech sector will be addressed. The location of the high tech sector in the Öresund region will be analysed and the region will also be related to other high tech regions in Europe....

  11. 78 FR 21491 - DeltaPoint Capital IV, L.P., DeltaPoint Capital IV (New York), L.P.; Notice Seeking Exemption...

    Science.gov (United States)

    2013-04-10

    ... SMALL BUSINESS ADMINISTRATION [License No. 02/02-0662, 02/02-0661] DeltaPoint Capital IV, L.P., DeltaPoint Capital IV (New York), L.P.; Notice Seeking Exemption Under Section 312 of the Small Business Investment Act, Conflicts of Interest Notice is hereby given that DeltaPoint Capital IV, L.P. and DeltaPoint...

  12. NASA Tech Briefs, January 2009

    Science.gov (United States)

    2009-01-01

    Tech Briefs are short announcements of innovations originating from research and development activities of the National Aeronautics and Space Administration. They emphasize information considered likely to be transferable across industrial, regional, or disciplinary lines and are issued to encourage commercial application. Topics covered include: The Radio Frequency Health Node Wireless Sensor System; Effects of Temperature on Polymer/Carbon Chemical Sensors; Small CO2 Sensors Operate at Lower Temperature; Tele-Supervised Adaptive Ocean Sensor Fleet; Synthesis of Submillimeter Radiation for Spectroscopy; 100-GHz Phase Switch/Mixer Containing a Slot-Line Transition; Generating Ka-Band Signals Using an X-Band Vector Modulator; SiC Optically Modulated Field-Effect Transistor; Submillimeter-Wave Amplifier Module with Integrated Waveguide Transitions; Metrology System for a Large, Somewhat Flexible Telescope; Economical Implementation of a Filter Engine in an FPGA; Improved Joining of Metal Components to Composite Structures; Machined Titanium Heat-Pipe Wick Structure; Gadolinia-Doped Ceria Cathodes for Electrolysis of CO2; Utilizing Ocean Thermal Energy in a Submarine Robot; Fuel-Cell Power Systems Incorporating Mg-Based H2 Generators; Alternative OTEC Scheme for a Submarine Robot; Sensitive, Rapid Detection of Bacterial Spores; Adenosine Monophosphate-Based Detection of Bacterial Spores; Silicon Microleaks for Inlets of Mass Spectrometers; CGH Figure Testing of Aspherical Mirrors in Cold Vacuums; Series-Coupled Pairs of Silica Microresonators; Precise Stabilization of the Optical Frequency of WGMRs; Formation Flying of Components of a Large Space Telescope; Laser Metrology Heterodyne Phase-Locked Loop; Spatial Modulation Improves Performance in CTIS; High-Performance Algorithm for Solving the Diagnosis Problem; Truncation Depth Rule-of-Thumb for Convolutional Codes; Efficient Method for Optimizing Placement of Sensors.

  13. Human capital in low-tech manufacturing

    DEFF Research Database (Denmark)

    Hansen, Teis; Winther, Lars; Hansen, Ronnie Fibæk

    2014-01-01

    An essential feature associated with the rise of the knowledge economy has been the increasing focus on the importance of human capital as a precondition for economic growth. Human capital has been found to have a positive impact on the economic growth of high-tech industries, however, the influe......An essential feature associated with the rise of the knowledge economy has been the increasing focus on the importance of human capital as a precondition for economic growth. Human capital has been found to have a positive impact on the economic growth of high-tech industries, however......, the influence of human capital on the development of low-tech industries is yet to be analysed. This paper provides such an examination of low-tech industries based on an analysis of employment data within manufacturing industries in Denmark in the period 1993–2006. The findings highlight, first, that human...... capital appears to be equally important for economic development in low-tech industries and, second, that the divide between the large urban regions, especially Copenhagen, and the rest of the country plays the primary role in explaining the geography of human capital. These findings stress the relevance...

  14. Blunt injury of the infrarenal inferior vena cava — imaging and ...

    African Journals Online (AJOL)

    Blunt injury of the infrarenal inferior vena cava — imaging and conservative management. Ian C Duncan, Basil J Sher, Leslie M Fingleson. Abstract. Isolated rupture of the infrarenal segment of the inferior vena cava due to blunt trauma is relatively rare. It may be missed clinically and even diagnostic peritoneal lavage may ...

  15. Kirurgisk radikal resektion af leiomyosarkom i retrohepatiske vena cava med intrakardial tumortrombosering

    DEFF Research Database (Denmark)

    Pedersen, Christian Ross; Larsen, Peter Nørgaard; Arendrup, Henrik C

    2005-01-01

    Sarcoma of the inferior vena cava (IVC) is a rare clinical entity. Surgical treatment of IVC is associated with improved survival. This case report describes a 42-year-old woman with biopsy-proven leiomyosarcoma of the inferior vena cava with intracardial tumour growth. The primary tumour was only...

  16. Widening of mediastinum with persistent left superior Vena cava - CT diagnosis

    International Nuclear Information System (INIS)

    Neuwirth, J.; Kolar, J.

    1992-01-01

    Described in this paper are radiographic findings recorded from a case of persistent left superior vena cava which grew manifest by widening of the left contour of the upper mediastinal region. Contrast-enhanced computed tomography (CT) was undertaken to clear up suspicion of mediastinal tumour and revealed double superior vena cava. The diagnosis was then confirmed by digital subtraction venography. (orig.) [de

  17. Computed tomographic diagnosis of calcified inferior vena cava thrombus in a child with Wilm's tumor

    Energy Technology Data Exchange (ETDEWEB)

    Kirks, D R; Ponzi, J W; Korobkin, M

    1980-01-01

    A calcified thrombus in the inferior vena cava of infants and children may be imaged by computed tomography. The precise location of the calcification within the inferior vena cava may be confirmed by computed tomographic scanning during injection of intravenous contrast material.

  18. Cine computed tomography for diagnosis of superior vena cava obstruction following the mustard operation

    International Nuclear Information System (INIS)

    Matherne, G.P.; Atkins, D.L.; Frey, E.E.; Smith, W.L.

    1987-01-01

    Superior vena caval obstruction is a well described complication following Mustard's repair for transposition of the great arteries. We report a case of a 6-year-old child with superior vena cava obstruction correctly diagnosed by Cine-CT. The advantages of imaging with Cine-CT for this complication are discussed. (orig.)

  19. Vena cava filter behavior and endovascular response : An experimental in vivo study

    NARCIS (Netherlands)

    Hoekstra, A; Hoogeveen, Y; Elstrodt, JM; Tiebosch, ATMG

    2003-01-01

    Purpose: To evaluate the behavior and endovascular response of a new nitinol permanent vena cava filter, the TrapEase. Methods: Percutaneous implantation of the filter was performed in six goats, with inferior vena cava (IVC) diameter close to that of man. Radiologic data concerning the IVC, filter

  20. FinTech in Norway : the effect of FinTech on the traditional Norwegian banking sector

    OpenAIRE

    Omreng, Stian; Gjendem, Ida

    2017-01-01

    The purpose of this thesis is to investigate the effect of FinTech on the Norwegian banking industry. We investigate the drivers of FinTech, the current and potential Norwegian FinTech market, and the international competitiveness of the Norwegian FinTech movement. We identify nine segments of FinTech within the traditional banking functions Financing, Asset management, Payments and Authentication, and we find the key drivers behind the rapid growth of the FinTech market as cha...

  1. Hepatic vena cava syndrome: New concept of pathogenesis.

    Science.gov (United States)

    Shrestha, Santosh Man; Kage, Masayoshi; Lee, Byung Boong

    2017-06-01

    Hepatic vena cava syndrome, also known as membranous obstruction of inferior vena cava (IVC), was considered a rare congenital disease and classified under Budd-Chiari syndrome. It is now recognized as a bacterial infection-induced disease related to poor hygiene. Localized thrombophlebitis of the IVC at the site close to hepatic vein outlets is the initial lesion which converts on resolution into stenosis or complete obstruction, the circulatory equilibrium being maintained by development of cavo-caval collateral anastomosis. These changes persist for the rest of the patient's life. The patient remains asymptomatic for a variable period until acute exacerbations occur, precipitated by bacterial infection, resulting in deposition of thrombi at the site of the lesion and endophlebitis in intrahepatic veins. Large thrombus close to hepatic vein outlets results in ascites from hepatic venous outflow obstruction, which is followed by development of venocentric cirrhosis. Endophlebitis of intrahepatic veins results in ischemic liver damage and development of segmental stenosis or membrane. Acute exacerbations are recognized clinically as intermittent jaundice and/or elevation of aminotransferase or ascites associated with neutrophil leukocytosis and elevation of C-reactive protein; sonologically, they are recognized as the presence of thrombi of different ages in IVC and thrombosis of intrahepatic veins. Development of liver cirrhosis and hepatocellular carcinoma is related to severity or frequency of acute exacerbations and not to duration or type of caval obstruction. Hepatic vena cava syndrome is a common co-morbid condition with other liver diseases in developing countries and it should be considered in differential diagnosis in patient with intermittent elevation serum bilirubin and or aminotransferase or development of ascites and cirrhosis. © 2017 The Japan Society of Hepatology.

  2. Concomitant Persistent Left Superior Vena Cava and Horseshoe Kidney

    Directory of Open Access Journals (Sweden)

    Faraz Jaffer

    2015-01-01

    Full Text Available Persistent left superior vena cava (PLSVC and horseshoe kidney (HSK are common congenital abnormalities; however presence of both in the same person is extremely rare. A patient with hepatitis C cirrhosis awaiting transplant presented with worsening liver dysfunction, diagnosed with acute renal failure secondary to hepatorenal syndrome, and required X-ray fluoroscopy guided tunneled venous catheter placement for hemodialysis. Review of imaging studies demonstrated coexistence of PLSVC and HSK. PLSVC in adulthood is usually incidental with the most common drainage pattern being without physiologic dysfunction. Isolated horseshoe kidney is still the most common of renal fusion anomalies; however etiology of coexistent PLSVC remains unknown.

  3. Leonardo da Vinci and Kethem-Kiveris vena.

    Science.gov (United States)

    Dolezal, Antonín; Skorepova-Honzlova, Zita; Jelen, Karel

    2012-01-01

    In the drawing of coitus by Leonardo da Vinci are pictured the contemporary hypotheses regarding this act. The authors analyze the mamillaruteral connection depicted by the artist and grow up to believe that this is a hypothetical kiveris vena, female vein described by Anatomist Master Nicolai Physicus from the Salerno School. The Hebrew roots were found in the name. The connection is described also by Mondino in The Anathomia. The same connection can be found in the picture of the pregnant woman in Fasciculus Medicinæ by Johannes De Ketham.

  4. Omental flap transposition for inferior vena cava filter penetration

    Directory of Open Access Journals (Sweden)

    Junji Yamaguchi, MD

    2017-03-01

    Full Text Available A 40-year-old woman presented with uterine malignancy, deep vein thrombosis, and nonmassive pulmonary embolism in both lungs. Gunter-tulip filter was inserted, because she had severe genital bleeding, which is one of the contraindications to anticoagulation therapy. Total hysterectomy was conducted and anticoagulation therapy was started afterward. The thrombus worsened perioperatively, and the filter could not be retrieved. Since there was lymph node recurrence, the second time operation was performed. During operation, the struts were found to be penetrating the inferior vena cava. Omental flap was used to cover the struts, and no associated complications occurred after operation.

  5. Symptomatic caval penetration by a Celect inferior vena cava filter

    International Nuclear Information System (INIS)

    Bogue, Conor O.; John, Philip R.; Connolly, Bairbre L.; Rea, David J.; Amaral, Joao G.

    2009-01-01

    We report a case of penetration of the inferior vena cava (IVC) by all four primary struts of a Celect caval filter in a 17-year-old girl with Klippel-Trenaunay syndrome. The girl presented with acute lower abdominal and right leg pain 17 days after filter insertion. An abdominal radiograph demonstrated that the filter had moved caudally and that the primary struts had splayed considerably since insertion. Contrast-enhanced CT confirmed that all four primary struts had penetrated the IVC wall. There was a small amount of retroperitoneal hemorrhage. The surrounding vessels and viscera were intact. The filter was subsequently retrieved without complication. (orig.)

  6. Extreme premature with persistent left superior vena cava.

    Science.gov (United States)

    Aboitiz-Rivera, Carlos Manuel; Blachman-Braun, Ruben; Parra-Pérez, Mariana Yazmin

    2017-10-01

    Persistent left superior vena cava (PLSVC) is a congenital anomaly, that results when there is an absence of the normal regression of the left common precardinal vein during embryogenesis. Usually, this anomaly remains asymptomatic, however, when the PLSVC drains into the left atrium this could lead to a right-to-left shunt. Additionally, this can result in inadvertent delivery of air or thrombus into the systemic circulation with potential neurologic, cardiac and renal complications. In this article, we present a case of an extreme premature Mexican newborn in which the diagnosis was made after placement of a percutaneous central venues catheter.

  7. New low pressure (LP) turbines for NE Krsko

    International Nuclear Information System (INIS)

    Nemcic, K.; Novsak, M.

    2004-01-01

    During the evaluation of possible future maintenance strategies on steam turbine in very short period of time, engineering decision was made by NE Krsko in agreement with Owners to replace the existing two Low Pressure (LP) Turbines with new upgrading LP Turbines. This decision is presented with review of the various steam turbine problems as: SCC on turbine discs; blades cracking; erosion-corrosion with comparison of various maintenance options and efforts undertaken by the NE Krsko to improve performance of the original low pressure turbines. This paper presents the NEK approach to solve the possible future problems with steam turbine operation in NE Krsko as pro-active engineering and maintenance activities on the steam turbine. This paper also presents improvements involving retrofits, confined to the main steam turbine path, with major differences between original and new LP Turbines as beneficial replacement because of turbine MWe upgrading and return capital expenditures.(author)

  8. Assisting the rehabilitation by hi-tech

    Directory of Open Access Journals (Sweden)

    Mateusz Tomanek

    2017-03-01

    Full Text Available High-tech, which the use is becoming increasingly popular in medicine, media and education has several advantages as increasing the number of persons to whom these services can hit. Example of such activities is the use of videoconference during rehabilitation, where patients perform basic exercises at home, and physiotherapist could control the movement by on-line video. The use of modern technology is only assisting the rehabilitation, rather than a complete replacement. As the purpose of the article was adopted to show the range of possibilities for the use of high-tech in rehabilitation.

  9. Arkansas Tech University TRIGA nuclear reactor

    International Nuclear Information System (INIS)

    Sankoorikal, J.; Culp, R.; Hamm, J.; Elliott, D.; Hodgson, L.; Apple, S.

    1990-01-01

    This paper describes the TRIGA nuclear reactor (ATUTR) proposed for construction on the campus of Arkansas Tech University in Russellville, Arkansas. The reactor will be part of the Center for Energy Studies located at Arkansas Tech University. The reactor has a steady state power level of 250 kW and can be pulsed with a maximum reactivity insertion of $2.0. Experience gained in dismantling and transporting some of the components from Michigan State University, and the storage of these components will be presented. The reactor will be used for education, training, and research. (author)

  10. Capped Lp approximations for the composite L0 regularization problem

    OpenAIRE

    Li, Qia; Zhang, Na

    2017-01-01

    The composite L0 function serves as a sparse regularizer in many applications. The algorithmic difficulty caused by the composite L0 regularization (the L0 norm composed with a linear mapping) is usually bypassed through approximating the L0 norm. We consider in this paper capped Lp approximations with $p>0$ for the composite L0 regularization problem. For each $p>0$, the capped Lp function converges to the L0 norm pointwisely as the approximation parameter tends to infinity. We point out tha...

  11. Electronics Technology. Tech Prep Competency Profile.

    Science.gov (United States)

    Lakeland Tech Prep Consortium, Kirtland, OH.

    This tech prep competency profile covers the occupation of electronics technician. Section 1 provides the occupation definition. Section 2 lists development committee members. Section 3 provides the leveling codes--abbreviations for grade level, (by the end of grade 12, by the end of associate degree), academic codes (communications, math, or…

  12. International banker to speak at Virginia Tech

    OpenAIRE

    Ho, Sookhan

    2004-01-01

    International banker David Bieri will give a talk, "Why Central Banks Manage Reserves," on Monday, April 5, 11 a.m. in 1045 Pamplin Hall on the Virginia Tech campus. His talk is part of the "International Business and Culture" guest lecture series sponsored by the Pamplin College of Business. The talk is free and open to the public.

  13. Supplier challenges in health tech innovation

    DEFF Research Database (Denmark)

    Rolfstam, Max

    Suppliers, in particular small innovative firms, is an important contributor not only for innovation in health-tech, but also a component to consider in the light of the emerging policy interest for using public procurement as a means to stimulate innovation. Research on barriers preventing...

  14. Is Education Facing a "Tech Bubble"?

    Science.gov (United States)

    Davis, Michelle R.

    2013-01-01

    Educational technology companies and entrepreneurs may face the risk of a "tech bubble," similar to the massive boom-and-bust that rocked the technology market in the late 1990s, according to market analysts and a recently released paper. A relatively new focus on K-12 educational technology as an investment vehicle, a surge of investors looking…

  15. URBox : High tech energy and informal housing

    NARCIS (Netherlands)

    Cuperus, Y.J.; Smets, D.

    2011-01-01

    This paper reports on the URBox concept encompassing the high tech end of solar energy and informal low cost and affordable housing. It aims to contribute to solving the global energy crisis by building solar energy settlements in deserts where land is affordable and sunshine in abundance. First the

  16. Primary research on direct multi-slice spiral CT venography in inferior vena cava

    International Nuclear Information System (INIS)

    Gong Peiyou; Liu Fengli; Ma Xianying; Zhao Li; Wang Liping; Li Xuehua; Li Jian

    2010-01-01

    Objective: To investigate the superiority of direct multi-slice spiral CT venography in inferior vena cava. Methods: Twenty-eight patients performed MSCT venography in inferior vena cava, including 2 cases with both indirect and direct venography, 10 cases with indirect venography, 20 cases with direct venography through unilateral or bilateral lower extremity venous injection. The image quality and enhancement degree of the inferior vena cava were compared in double-blind method. Results: Of 10 cases with indirect venography of inferior vena cava, 1 case was failed due to mild enhancement in inferior vena cava. Image quality was good in 2 cases, poor in 7 cases, no excellent case. Of 20 cases with direct venography of inferior vena cava, the enhancement degree was scored 1, 2 degree in 16, 4 cases respectively and no case was scored 3 degree, the image quality was excellent, good in 16, 4 cases and no case was bad. The success rate was 100%. Conclusion: The image quality of direct MSCT venography in inferior vena cava is better than that of indirect method. (authors)

  17. Pharmacist and Technician Perceptions of Tech-Check-Tech in Community Pharmacy Practice Settings.

    Science.gov (United States)

    Frost, Timothy P; Adams, Alex J

    2018-04-01

    Tech-check-tech (TCT) is a practice model in which pharmacy technicians with advanced training can perform final verification of prescriptions that have been previously reviewed for appropriateness by a pharmacist. Few states have adopted TCT in part because of the common view that this model is controversial among members of the profession. This article aims to summarize the existing research on pharmacist and technician perceptions of community pharmacy-based TCT. A literature review was conducted using MEDLINE (January 1990 to August 2016) and Google Scholar (January 1990 to August 2016) using the terms "tech* and check," "tech-check-tech," "checking technician," and "accuracy checking tech*." Of the 7 studies identified we found general agreement among both pharmacists and technicians that TCT in community pharmacy settings can be safely performed. This agreement persisted in studies of theoretical TCT models and in studies assessing participants in actual community-based TCT models. Pharmacists who had previously worked with a checking technician were generally more favorable toward TCT. Both pharmacists and technicians in community pharmacy settings generally perceived TCT to be safe, in both theoretical surveys and in surveys following actual TCT demonstration projects. These perceptions of safety align well with the actual outcomes achieved from community pharmacy TCT studies.

  18. 77 FR 77122 - Pyxis Capital, L.P., et al.;

    Science.gov (United States)

    2012-12-31

    ... SECURITIES AND EXCHANGE COMMISSION [Investment Company Act Release No. 30316; 812-13489-01] Pyxis Capital, L.P., et al.; Notice of Application December 21, 2012. AGENCY: Securities and Exchange Commission (the ``Commission''). ACTION: Notice of an application for an order under section 6(c) of the...

  19. 75 FR 45611 - Texas Eastern Transmission LP; Notice of Application

    Science.gov (United States)

    2010-08-03

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP10-471-000] Texas Eastern Transmission LP; Notice of Application July 27, 2010. Take notice that on July 15, 2010, Texas Eastern Transmission (Texas Eastern), P.O. Box 1642, Houston, Texas 77251-1642, filed in Docket No. CP10-471-000, an...

  20. 78 FR 64933 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2013-10-30

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-4-000] Texas Eastern Transmission, LP; Notice of Application Take notice that on October 10, 2013, Texas Eastern Transmission, (Texas Eastern), having its principal place of business at 5400 Westheimer Court, Houston, Texas, 77056...

  1. 76 FR 18210 - Texas Eastern Transmission, LP; Notice of Application

    Science.gov (United States)

    2011-04-01

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-138-000] Texas Eastern Transmission, LP; Notice of Application On March 15, 2011, Texas Eastern Transmission Corporation (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056-5310, filed with the Federal Energy Regulatory...

  2. Sunoco Pipeline, L.P. Clean Water Act Settlement - 2017

    Science.gov (United States)

    EPA, and the U.S. Department of Justice announced that Sunoco Pipeline, L.P. (Sunoco) has agreed to pay a civil penalty for alleged violation of the Clean Water Act stemming from a 2012 gasoline discharge near Wellington, Ohio.

  3. View of the LP gas supply/demand in Asia and a survey of the Middle East trend; Asia no LP gas jukyu tenbo to Chuto doko chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-09-01

    A study was made on the LP gas supply/demand in Asia including an outlook for 2000. Eleven countries in Asia including NIES countries, ASEAN countries, China and India have been continuing their rapid growth of economy and have rapidly been increasing their energy consumption. There, LP gas spreads as a home use fuel, and countries excluding some LP gas producing countries depend considerably upon the import from the Middle East. The LP gas consumption quantity is steadily increasing in China and India having huge population, etc., and dependence of LP gas is increasing upon LP gas producing countries of the Middle East. Nevertheless, in the Middle East, the domestic consumption of LP gas, mostly butane, is increasing. Namely, butane is used as raw material of MTBE, and LP gas as that of petroleum chemicals. The Middle East has a lot of plant projects of a sizable size in the future, which predicts that LP gas export from LP gas producing countries of the Middle East is decreasing. 2 refs., 62 figs., 57 tabs.

  4. 78 FR 47546 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2013-08-06

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Model... Aviation Authority of Israel (CAAI), which is the aviation authority for Israel, has issued Israeli...

  5. 76 FR 41041 - Special Conditions: Gulfstream Aerospace LP (GALP) Model G250 Airplane, Interaction of Systems...

    Science.gov (United States)

    2011-07-13

    ... Conditions No. 25-439-SC] Special Conditions: Gulfstream Aerospace LP (GALP) Model G250 Airplane, Interaction... special conditions are issued for the Gulfstream Aerospace LP (GALP) Model G250 airplane. This airplane...

  6. Creation of the permanent inferior vena cava filter for prevention of pulmonary artery embolism

    Directory of Open Access Journals (Sweden)

    Yа.O. Povar

    2016-05-01

    Full Text Available The aim of the study was to create a new permanent cava filter to improve functional capacities of the construction and achieve high clinical parameters. A new geometry of the permanent inferior vena cava filter was presented which has high blood clot-capturing ability, does not cause thrombus fragmentation, makes migration impossible. The inferior vena cava filter does not injure the vessel wall and preserves integrity under long-term use. The inferior vena cava filter installation is safe and controllable, the filter self-positioning and reposition are possible, the delivery system size is 6F, the blood flow changing is minimal.

  7. Commercial introduction of the Advanced NOxTECH system

    Energy Technology Data Exchange (ETDEWEB)

    Sudduth, B.C. [NOxTECH, Inc., Irvine, CA (United States)

    1997-12-31

    NOxTECH is BACT for diesel electric generators. Emissions of NO{sub x} are reduced 95% or more with substantial concurrent reductions in CO, particulates, and ROG`s. No engine modifications or other exhaust aftertreatments can remove all criteria pollutants as effectively as NOxTECH. The NOxTECH system reliably maintains NH{sub 3} slip below 2 ppm. Unlike other emissions controls, NOxTECH does not generate hazardous by-products. The Advanced NOxTECH system reduces the size, weight, and cost for BACT emissions reductions. Based on the operation of a 150 kW prototype, NOxTECH, Inc. is quoting commercial units for diesel electric generators. Advanced NOxTECH equipment costs about half as much as SCR systems, and NO{sub x} reduction can exceed 95% with guarantees for emissions compliance.

  8. Right-sided duplication of the inferior vena cava and the common iliac vein: hidden hinds in spiral-computed tomography; Rechtsseitige Dopplung der Vena cava inferior und Vena iliaca communis: Bildgebung mit der Spiral-Computertomographie

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, D.R.; Friedrich, M. [Krankenhaus am Urban (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin; Andresen, R. [Staedtisches Krankenhaus Zehlendorf, Behring (Germany). Abt. fuer Roentgendiagnostik und Nuklearmedizin

    1998-05-01

    Duplications of the inferior vena cava (IVC) are rare variants of the abdominal vessels and are normally located on both sides of the abdominal aorta. The rare case of a rightsided infrarenal duplication of the IVC with involvement of the common iliac vein is reported. Details of the embryology are presented for the understanding of this IVC variant. The spiral CT with multiplanar reconstructions makes it possible to define the vascular morphology and to differentiate it from lymphoma. (orig.) [Deutsch] Duplikaturen der Vena cava inferior (VCI) sind seltene meist bilateral der Aorta abdominalis gelegene abdominelle Gefaessvarianten. Der ungewoehnliche Fall einer rechtsseitigen infrarenalen Dopplung der VCI mit Beteiligung der Vena iliaca communis wird dargestellt. Auf der Embryologie wird, soweit fuer das Verstaendnis der vorliegenden VCI-Variante notwendig, eingegangen. Die Spiral-CT mit multiplanaren Rekonstruktionen erlaubt die morphologische Beschreibung der Gefaesssituation und die Differenzierung gegenueber Lymphomen. (orig.)

  9. The superior vena cava syndrome caused by malignant disease

    International Nuclear Information System (INIS)

    Eren, Suat; Karaman, Adem; Okur, Adnan

    2006-01-01

    Objective: The superior vena cava (SVC) obstruction by malignant diseases is either by direct invasion and compression or by tumour thrombus of the SVC. Whatever is its cause, obstruction of the SVC causes elevated pressure in the veins draining into the SVC and increased or reversed blood flow through collateral vessels. Severity of the syndrome depends on the collateral vascular system development. Therefore, imaging of the collateral veins with variable location and connection is important in determining the extension and management of the disease. Our aims are to describe collateral vessels of the superior vena cava syndrome (SVCS) related with the malignant diseases and to assess the ability of multi-detector row CT with multiplanar and 3D volume rendering techniques in determining and describing collateral circulations. Materials and methods: We present CT angiography findings of seven patients with small cell carcinoma of the lung (n = 2), squamous cell carcinoma of the lung (n = 3), Hodgkin disease of the thorax (n = 1), and squamous cell carcinoma of the oesophagus (n = 1). The patients received contrast-enhanced CT scans of the chest and abdomen on a multi-detector row CT during breath holding at suspended inspiration. Results: CT images revealed the cause and level of the SVC obstruction in all patients with axial and multiplanar reconstructed images. The SVC showed total obstruction in five patients and partial obstruction in two patients. The most common experienced collateral vessels were azygos vein (6), intercostal veins (6), mediastinal veins (6), paravertebral veins (5), hemiazygos vein (5), thoracoepigastric vein (5), internal mammary vein (5), thoracoacromioclavicular venous plexus (5), and anterior chest wall veins (5). While one case showed the portal-systemic shunt, V. cordis media and sinus coronarius with phrenic veins were enlarged in two cases, and the left adrenal vein was enlarged in a patient. In one case, the azygos vein with reversed

  10. The superior vena cava syndrome caused by malignant disease

    Energy Technology Data Exchange (ETDEWEB)

    Eren, Suat [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)]. E-mail: suateren@atauni.edu.tr; Karaman, Adem [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey); Okur, Adnan [Department of Radiology, Faculty of Medicine, Atatuerk University, 25240 Erzurum (Turkey)

    2006-07-15

    Objective: The superior vena cava (SVC) obstruction by malignant diseases is either by direct invasion and compression or by tumour thrombus of the SVC. Whatever is its cause, obstruction of the SVC causes elevated pressure in the veins draining into the SVC and increased or reversed blood flow through collateral vessels. Severity of the syndrome depends on the collateral vascular system development. Therefore, imaging of the collateral veins with variable location and connection is important in determining the extension and management of the disease. Our aims are to describe collateral vessels of the superior vena cava syndrome (SVCS) related with the malignant diseases and to assess the ability of multi-detector row CT with multiplanar and 3D volume rendering techniques in determining and describing collateral circulations. Materials and methods: We present CT angiography findings of seven patients with small cell carcinoma of the lung (n = 2), squamous cell carcinoma of the lung (n = 3), Hodgkin disease of the thorax (n = 1), and squamous cell carcinoma of the oesophagus (n = 1). The patients received contrast-enhanced CT scans of the chest and abdomen on a multi-detector row CT during breath holding at suspended inspiration. Results: CT images revealed the cause and level of the SVC obstruction in all patients with axial and multiplanar reconstructed images. The SVC showed total obstruction in five patients and partial obstruction in two patients. The most common experienced collateral vessels were azygos vein (6), intercostal veins (6), mediastinal veins (6), paravertebral veins (5), hemiazygos vein (5), thoracoepigastric vein (5), internal mammary vein (5), thoracoacromioclavicular venous plexus (5), and anterior chest wall veins (5). While one case showed the portal-systemic shunt, V. cordis media and sinus coronarius with phrenic veins were enlarged in two cases, and the left adrenal vein was enlarged in a patient. In one case, the azygos vein with reversed

  11. 75 FR 38514 - Application to Export Electric Energy; Brookfield Energy Marketing LP

    Science.gov (United States)

    2010-07-02

    ... Energy Marketing LP AGENCY: Office of Electricity Delivery and Energy Reliability, DOE. ACTION: Notice of application. SUMMARY: Brookfield Energy Marketing LP (BEM LP) has applied for authority to transmit electric... surplus energy purchased from electric utilities, Federal power marketing agencies and other entities...

  12. LpMab-19 Recognizes Sialylated O-Glycan on Thr76 of Human Podoplanin.

    Science.gov (United States)

    Ogasawara, Satoshi; Kaneko, Mika K; Kato, Yukinari

    2016-08-26

    Human podoplanin (hPDPN) is expressed in lymphatic vessels, pulmonary type-I alveolar cells, and renal glomerulus. The hPDPN/C-type lectin-like receptor-2 (CLEC-2) interaction is involved in platelet aggregation and cancer metastasis. High expression of hPDPN in cancer cells or cancer-associated fibroblasts (CAFs) leads to a poor prognosis for cancer patients. In our previous research, we reported on several anti-hPDPN monoclonal antibodies (mAbs), including LpMab-2, LpMab-3, LpMab-7, LpMab-9, LpMab-12, LpMab-13, and LpMab-17 of mouse IgG 1 subclass, which were produced using CasMab technology. Here we produced a novel anti-hPDPN mAb LpMab-19 of mouse IgG 2b subclass. Flow cytometry revealed that the epitope of LpMab-19 includes O-glycan, which is attached to Thr76 of hPDPN. We further identified the minimum epitope of LpMab-19 as Thr76-Arg79 of hPDPN. Immunohistochemistry revealed that LpMab-19 is useful for detecting not only normal cells, including lymphatic vessels, but also glioblastoma and oral squamous cell carcinoma cells. LpMab-19 could be useful for investigating the physiological function of O-glycosylated hPDPN.

  13. 78 FR 11567 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2013-02-19

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Model Gulfstream G150... Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.): Amendment 39...

  14. 76 FR 70040 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2011-11-10

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Aerospace LP (type certificate previously held by Israel Aircraft Industries, Ltd.) Model Galaxy and... new AD: 2011-23-07 Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft...

  15. Plasma Lp-PLA2 mass and apoB-lipoproteins that carry Lp-PLA2 decrease after sodium

    NARCIS (Netherlands)

    Constantinides, Alexander; Kerstens, Michiel N.; Dikkeschei, Bert D.; van Pelt, L. Joost; Tellis, Constantinos C.; Tselepis, Alexandros D.; Dullaart, Robin P. F.

    2012-01-01

    Eur J Clin Invest 2012; 42 (11): 12351243 Abstract Background Lipoprotein-associated phospholipase A2 (Lp-PLA2) is a novel cardiovascular risk marker, which is predominantly complexed to apolipoprotein (apo) B-containing lipoproteins in human plasma. As increasing dietary sodium intake may decrease

  16. Marker-Negative Pheochromocytoma Associated with Inferior Vena Cava Thrombosis

    Directory of Open Access Journals (Sweden)

    S. Poudyal

    2017-01-01

    Full Text Available Pheochromocytoma associated with inferior vena cava (IVC thrombosis is very rare. A 27-year-old female presented with right flank pain and hypertensive urgency. Contrast-enhanced CT abdomen and gadolinium-contrast MRI abdomen revealed right adrenal mass suspicious of malignancy with invasion and compression to the right IVC wall along with IVC thrombus extending from the level of renal veins to the level of confluence with hepatic veins. Her routine laboratory investigations including 24-hour urine fractionated metanephrines, vanillylmandelic acid, and cortisol were normal. Right adrenalectomy with IVC thrombectomy was done. Perioperative period was uneventful. Histopathology of the mass turned out to be pheochromocytoma with thrombus revealing fibroadipose tissue with fibrin. Pheochromocytoma may present with IVC thrombus as well as normal serum and urinary markers. Thus, clinical suspicion is imperative in perioperative management of adrenal mass.

  17. Indications, management, and complications of temporary inferior vena cava filters

    International Nuclear Information System (INIS)

    Linsenmaier, Ulrich; Rieger, Johannes; Schenk, Franz; Rock, Clemens; Mangel, Eugen; Pfeifer, Klaus Juergen

    1998-01-01

    Purpose: We describe the results of a preliminary prospective study using different recently developed temporary and retrievable inferior vena cava (IVC) filters.Methods: Fifty temporary IVC filters (Guenther, Guenther Tulip, Antheor) were inserted in 47 patients when the required period of protection against pulmonary embolism (PE) was estimated to be less than 2 weeks. The indications were documented deep vein thrombosis (DVT) and temporary contraindications for anticoagulation, a high risk for PE, and PE despite DVT prophylaxis.Results: Filters were removed 1-12 days after placement and nine (18%) had captured thrombi. Complications were one PE during and after removal of a filter, two minor filter migrations, and one IVC thrombosis.Conclusion: Temporary filters are effective in trapping clots and protecting against PE, and the complication rate does not exceed that of permanent filters. They are an alternative when protection from PE is required temporarily, and should be considered in patients with a normal life expectancy.

  18. Venous Thromboembolism After Removal of Retrievable Inferior Vena Cava Filters

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Tanaka, Osamu; Yoshimatsu, Rika; Miura, Hiroshi; Nishimura, Tsunehiko

    2010-01-01

    The purpose of this study was to examine the incidence of new or recurrent venous thromboembolism (VTE) after retrieval of inferior vena cava (IVC) filters and risk factors associated with such recurrence. Between March 2001 and September 2008, at our institution, implanted retrievable vena cava filters were retrieved in 76 patients. The incidence of new or recurrent VTE after retrieval was reviewed and numerous variables were analyzed to assess risk factors for redevelopment of VTE after filter retrieval. In 5 (6.6%) of the 76 patients, redevelopment or worsening of VTE was seen after retrieval of the filter. Three patients (4.0%) had recurrent deep venous thrombosis (DVT) in the lower extremities and 2 (2.6%) had development of pulmonary embolism, resulting in death. Although there was no significant difference in the incidence of new or recurrent VTE related to any risk factor investigated, a tendency for development of VTE after filter retrieval was higher in patients in whom DVT in the lower extremities had been so severe during filter implantation that interventional radiological therapies in addition to traditional anticoagulation therapies were required (40% in patients with recurrent VTE vs. 23% in those without VTE; p = 0.5866 according to Fisher's exact probability test) and in patients in whom DVT remained at the time of filter retrieval (60% in patients with recurrent VTE vs. 37% in those without VTE; p = 0.3637). In conclusion, new or recurrent VTE was rare after retrieval of IVC filters but was most likely to occur in patients who had severe DVT during filter implantation and/or in patients with a DVT that remained at the time of filter retrieval. We must point out that the fatality rate from PE after filter removal was high (2.6%).

  19. Percutaneous placement of bird's nest inferior vena cava filter

    International Nuclear Information System (INIS)

    Lee, Seung Hoon; Sung, Kyu Bo; Yoon, Hyun Ki

    1999-01-01

    To describe clinical experiences of the use of Bird's Nest inferior vena cava(IVC) filter. Between August 1991 and August 1997, IVC filter was percutaneously inserted in 51 patients with pulmonary embolism(PE) and deep vein thrombosis of the lower extremities. Indications for the placement of this filter were contraindication to anticoagulation in 17 patients, prophylaxis of PE in 17, failed anticoagulation in 11, massive PE with residual floating thrombus in three and complications involving anticoagulation in 3. In order to delineate the location of renal vein and extension of deep vein thrombosis into the IVC, all patients under went inferior vena cavography before filter placement. Thirty filters were inserted through the right femoral vein, 19 through the right internal jugular vein and three through the left femoral vein. The patients involved were followed up for periods ranging from one week to six years (mean 10 months). A Bird's Nest IVC filter was placed in the infrarenal IVC in 44 patients and in the suprarenal IVC in 7. Certain complicatioins ensued. IVC penetration occurred in three patients(5.9%), and in seven(1.37%) the filter wire prolapsed. Except for transient pain, however, there were no serious IVC penetration-related complications and no evidence of recurrence of PE in the cases involving prolapse of the filter wire. During follow up, clinically suspected recurrent PE was noted in two patients(3.9%), but there was no evidence of newly developed occlusion of the IVC. In patients who under went follow up, Bird's Nest IVC filter effectively prevented the development and recurrence of PE, and there were no complications. To prevent of penetration of the IVC and prolapse of the filter, however, technical skill was needed

  20. Simon nitinol vena cava filters: effectiveness and complications

    International Nuclear Information System (INIS)

    Wolf, F.; Thurnher, S.; Lammer, J.

    2001-01-01

    Purpose: The aim of this retrospective analysis was to evaluate the clinical safety and effectiveness of the simon nitinol inferior vena cava filter (SNF) for prevention of pulmonary embolism. Patients and Methods: 117 patients (63 male, 54 female; aged 58.38 ± 14.59 years) underwent percutaneous implantation of an SNF from 1993 through 1999. Patient reports were retrospectively analysed for complications during and after implantation and deep venous thrombosis (DVT) and pulmonary embolism before and after implantation. Helical-CT with contrast media and plain abdominal radiography were performed on 35 patients, helical-CT alone on two patients. We checked the position and configuration of the SNF and looked for a perforation of the filter legs through the wall of the inferior vena cava (IVC). The IVC and deep pelvic veins were analysed for patency. Results: During implantation 10 of 117 (9%) patients had minor complications, major complications were reported in 0.9% (1/117). There was no significant increase in thrombosis of the deep pelvic veins and the IVC after implantation. Pulmonary re-embolism (PE) was documented in 9 out of 117 patients (7.7%). One out of the 35 examined patients (2.9%) showed a single strut fracture of the SNF. Tilting more than 15 was seen in 7 out of 37 patients (19%). Dislocation of the SNF more than 10 mm occurred in one out of 35 patients (2.9%), perforation through the wall of the IVC in all 37 patients. We found no occlusion of the IVC. (orig.) [de

  1. Deep Venous Thrombosis Associated With Inferior Vena Cava Abnormalities And Hypoplastic Kidney In Siblings

    Directory of Open Access Journals (Sweden)

    Duicu Carmen

    2016-06-01

    Full Text Available Congenital inferior vena cava anomalies have a reduced frequency in general population, many times being an asymptomatic finding. Patients caring such anomalies are at risk to develop deep vein thrombosis. In this paper, we present 2 siblings with deep venous thrombosis and inferior vena cava abnormalities, with a symptomatic onset at similar age. The inferior vena cava abnormality was documented by an angio-CT in each case. The thrombophilic workup was negative. Patients were treated with conservative therapy: low molecular weight heparin anticoagulants converted later to oral anticoagulant with resolution of symptoms and disappearance of the thrombus. Finally, in the absence of any risk factor in a young patient admitted with deep vein thrombosis investigations to exclude inferior vena cava anomalies are mandatory.

  2. Is there a relationship between the diameter of the inferior vena cava ...

    African Journals Online (AJOL)

    2015-04-12

    Apr 12, 2015 ... Key words: Central venous pressures, critically ill patients, inferior vena cava. Date of Acceptance: ... Regardless of the cause of the patient's status, the blood/ .... AUC=Area under ROC curve, IAP=Anteroposterior diameter of.

  3. Inferior vena cava filter penetration following Whipple surgical procedure causing ureteral injury.

    Science.gov (United States)

    Abdel-Aal, Ahmed Kamel; Ezzeldin, Islam B; Moustafa, Amr Soliman; Ertel, Nathan; Oser, Rachel

    2015-12-01

    We report a case of an indwelling inferior vena cava filter that penetrated the IVC wall after Whipple's pancreatico-duodenectomy procedure performed in a patient with ampullary carcinoma, resulting in right ureteral injury and obstruction with subsequent hydroureter and hydronephrosis. This was incidentally discovered on a computed tomography scan performed as routine follow up to evaluate the results of the surgery. We retrieved the inferior vena cava filter and placed a nephrostomy catheter to relieve the ureteral obstruction. Our case highlights the importance of careful inferior vena cava manipulation during abdominal surgery in the presence of an inferior vena cava filter, and the option of temporary removal of the filter to be placed again after surgery in order to avoid this complication, unless protection is required against clot migration during the surgical procedure.

  4. Nurturing a FinTech Ecosystem

    DEFF Research Database (Denmark)

    Leong, Carmen; Tan, Barney; Xiao, Xiao

    2017-01-01

    Financial technology, or FinTech, involves the design and delivery of financial products and services through technology. It impacts financial institutions, regulators, customers, and merchants across a wide range of industries. Pervasive digital technologies are challenging the fundamentals...... of the highly regulated financial sector, leading to the emergence of non-traditional payment systems, peer-to-peer money exchanges and increased turbulence in currency markets. This case study explores the development of a FinTech company in China that offers microloans to college students. Five lessons...... learned are presented for organizations to better manage the challenges and to leverage the opportunities amidst the disruption of financial sector. Our findings also shed light on how digital technology 1) offers the strategic capability for a firm to occupy a market niche in financial sector, 2) enables...

  5. Radiological evidence of double inferior vena cava in a young adult male

    International Nuclear Information System (INIS)

    Nevruz, O.; Ural, U.; Kirici, Y.; Kilic, C.; Bozlar, U.

    2007-01-01

    The development of the inferior vena cava IVC is a complex process comprising the formation and regression of some anastomoses, so various anomalies may occur during embryogenesis. These variations can increase the difficulty of aneurysm resection as well as the risk of venous injury and subsequent excessive bleeding during retroperitoneal and thoracic surgical interventions. Here, we report a patient with double inferior vena cava by radiographically during his investigation for the etiology of pancytopenia. (author)

  6. Spontaneous tilting after placement of the gunther-tulip inferior vena caval filter: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Tae Seok; Cha, In Ho; Seol, Hae Young; Park, Cheol Min [Guro Hospital, Korea University College of Medicine, Seoul (Korea, Republic of)

    2006-10-15

    Tilting of a deployed filter in the inferior vena cava (IVC) is a particular kind of periprocedural complication and this can reduce the filter's clot-trapping ability and increase the occlusion of the IVC at a later period. The authors report here on a case of spontaneous tilting of an inferior vena caval filter that was associated with thrombosis in the IVC within 2 weeks of the initially successful placement of the filter without tilting.

  7. Spontaneous tilting after placement of the gunther-tulip inferior vena caval filter: a case report

    International Nuclear Information System (INIS)

    Seo, Tae Seok; Cha, In Ho; Seol, Hae Young; Park, Cheol Min

    2006-01-01

    Tilting of a deployed filter in the inferior vena cava (IVC) is a particular kind of periprocedural complication and this can reduce the filter's clot-trapping ability and increase the occlusion of the IVC at a later period. The authors report here on a case of spontaneous tilting of an inferior vena caval filter that was associated with thrombosis in the IVC within 2 weeks of the initially successful placement of the filter without tilting

  8. FuSuMaTech workshop

    CERN Multimedia

    Olofsson, Simon

    2018-01-01

    The goal of the FuSuMaTecH IP workshop, organised at CERN Ideaquare 19-20 April, was to educate superconductivity and magnet experts about intellectual property. About 30 participants from multiple institutes and companies worked together in this two day interactive program which was facilitated by CERN Knowledge Transfer. Great progress was made in shaping the FuSuMaTech industrial demonstrator projects as well as the R&D&I subjects.

  9. Hi tech microeconomics and information nonintensive calculi

    Directory of Open Access Journals (Sweden)

    Mirko Dohnal

    2013-11-01

    Full Text Available The article establishes link between the contributions made to the study of hi tech phenomena. It analyzes the evolution undergone by studies on the topic of the knowledge economics (HI-TECH process carried out by different disciplines (hard and soft sciences – sociology, ecology etc. from the point of view of the objectives they pursue. The attentions are concentrated on analysis of applicable mathematical tools used to develop realistic formal models. Information intensity is defined as the amount of information which is needed for the realistic application of a corresponding formal tool. High information intensity is desirable because it influences the model accuracy. Low information intensity is preferred when high information intensity requires more information items than are available and this is usually the case in knowledge engineering. Fuzzy models seem to be a useful extension of formal tool used in hi tech microeconomics. However, even fuzzy sets could be prohibitively information intensive. Therefore the range of available formal tools must be considerably broader. This paper introduces qualitative and semiqualitative models and rough sets. Each formal tool is briefly characterized.

  10. TurboTech Technical Evaluation Automated System

    Science.gov (United States)

    Tiffany, Dorothy J.

    2009-01-01

    TurboTech software is a Web-based process that simplifies and semiautomates technical evaluation of NASA proposals for Contracting Officer's Technical Representatives (COTRs). At the time of this reporting, there have been no set standards or systems for training new COTRs in technical evaluations. This new process provides boilerplate text in response to interview style questions. This text is collected into a Microsoft Word document that can then be further edited to conform to specific cases. By providing technical language and a structured format, TurboTech allows the COTRs to concentrate more on the actual evaluation, and less on deciding what language would be most appropriate. Since the actual word choice is one of the more time-consuming parts of a COTRs job, this process should allow for an increase in quantity of proposals evaluated. TurboTech is applicable to composing technical evaluations of contractor proposals, task and delivery orders, change order modifications, requests for proposals, new work modifications, task assignments, as well as any changes to existing contracts.

  11. Evaluation of gradual occlusion of the caudal vena cava in clinically normal dogs.

    Science.gov (United States)

    Peacock, John T; Fossum, Theresa W; Bahr, Anne M; Miller, Matthew W; Edwards, John F

    2003-11-01

    To devise a technique for gradual occlusion of the caudal vena cava in dogs and determine effects of complete occlusion of the caudal vena cava. 8 mixed-breed hounds that weighed between 25 and 30 kg. Baseline evaluation of dogs included serum biochemical analyses and determination of glomerular filtration rate (GFR) with dynamic renal scintigraphy and plasma clearance analysis. An occluder was placed around the vena cava in the region cranial to the renal veins. The occluder was attached to a vascular access port. The vena cava was gradually occluded over 2 weeks. The GFR was measured every 2 weeks after surgery, and venograms were performed every 3 weeks after surgery. Blood samples were collected every 48 hours for the first week and then weekly thereafter to measure BUN and creatinine concentrations and activities of alanine transaminase, alkaline phosphatase, and creatinine kinase. Dogs were euthanatized 6 weeks after surgery, and tissues were submitted for histologic examination. The GFR and biochemical data were compared with baseline values. Gradual occlusion of the caudal vena cava was easily and consistently performed with this method, and adverse clinical signs were not detected. Formation of collateral vessels allowed overall GFR to remain constant despite a decrease in function of the left kidney. Measured biochemical values did not deviate from reference ranges. Gradual occlusion of the caudal vena cava may allow removal of adrenal gland tumors with vascular invasion that would otherwise be difficult or impossible to resect.

  12. Multidetector row computed tomography and ultrasound characteristics of caudal vena cava duplication in dogs.

    Science.gov (United States)

    Bertolini, Giovanna; Diana, Alessia; Cipone, Mario; Drigo, Michele; Caldin, Marco

    2014-01-01

    Caudal vena cava duplication has been rarely reported in small animals. The purpose of this retrospective study was to describe characteristics of duplicated caudal vena cava in a large group of dogs. Computed tomography (CT) and ultrasound databases from two hospitals were searched for canine reports having the diagnosis "double caudal vena cava." One observer reviewed CT images for 71 dogs and two observers reviewed ultrasound images for 21 dogs. In all CT cases, the duplication comprised two vessels that were bilaterally symmetrical and approximately the same calibre (similar to Type I complete duplication in humans). In all ultrasound cases, the duplicated caudal vena cava appeared as a distinct vessel running on the left side of the abdominal segment of the descending aorta and extending from the left common iliac vein to the left renal vein. The prevalence of caudal vena cava duplication was 0.46% for canine ultrasound studies and 2.08% for canine CT studies performed at these hospitals. Median body weight for affected dogs was significantly lower than that of unaffected dogs (P dogs, caudal vena cava duplication should be differentiated from other vascular anomalies when planning surgeries and for avoiding misdiagnoses. © 2014 American College of Veterinary Radiology.

  13. Interrupted inferior vena cava with hemiazygos continuation in an adult with a persistent left superior vena cava and left single coronary artery: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeo Jin; Kwon, Se Hwan; Ahn, Sung Eun; Kim, Soo Joong; Oh, Joo Hyeong [College of Medicine, Kyung Hee University, Seoul (Korea, Republic of); Shin, Jong Soo [Dept. of Radiology, Kyung Hee University Hospital at Gangdong, Seoul (Korea, Republic of)

    2016-06-15

    A 50-year-old woman was referred to our institution for medical screening due to an incidental finding on abdominal ultrasonography. She underwent chest, abdomen and cardiac multi-detector computed tomography (MDCT). Her MDCT revealed absence of the hepatic segment of the inferior vena cava (IVC), with hemiazygos continuation and a left single coronary artery. The dilated hemiazygos vein drained directly into the persistent left superior vena cava (SVC). Herein, we reported a very rare case combining an incidentally found interrupted IVC with hemiazygos vein continuation, persistent left SVC and a left single coronary artery diagnosed by MDCT.

  14. Tech Prep Marketing Guide. The Complete Book of Strategies and Practical Experiences.

    Science.gov (United States)

    Williamson, Patty

    This guide explains the concept of marketing tech prep and provides marketing principles and strategies to promote tech prep programs. The guide covers the following topics: (1) why it is necessary to market tech prep; (2) what a comprehensive tech prep marketing plan should include; (3) targeting the benefits message; (4) marketing tech prep to…

  15. Dødshjælp, drabsforbud og deontologi

    DEFF Research Database (Denmark)

    Dige, Morten

    2008-01-01

    Et velkendt argument imod aktiv dødshjælp har det deontologiske forbud mod drab eller pligten til ikke at slå ihjel som en central præmis. Sådanne deontologiske argumenter spiller en fremtrædende rolle i nylige publikationer fra Det Etiske Råd. For at gælde ukvalificeret, må disse argumenter imid...

  16. Who's who in the LP-Gas industry

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    All pertinent information about the most important North American companies in the LP-Gas industry are listed alphabetically in an easy-to-use directory. A total of 395 listings are included. Besides company names and addresses, other information such as key personnel and products produced and marketed to affiliated companies, and a list of other services offered by each company are also provided

  17. Liquid-phase problems in steam turbine LP stages

    International Nuclear Information System (INIS)

    Blanc-Feraud, P.

    1978-01-01

    Wet steam formation owing to incipient condensation in final steam turbine pressure stages results in a loss of efficiency and possible rotor blading erosion. The effects of erosion are now clearly understood and quite easily counteracted, but loss of thermodynamics, mechanical and aerodynamic efficiency is still a problem. Only the final LP stages of conventional power station plant operate with wet steam, whereas nuclear plant turbines use it to produce most of their total output [fr

  18. LP turbine retrofit modernization: Improvements in performance and operation

    International Nuclear Information System (INIS)

    Groenedaal, J.C.; Fowls, L.G.; Subbiah, R.; Maxwell, B.P.; Persson, B.

    1996-01-01

    Westinghouse Electric Corporation retrofitted six low pressure (LP) nuclear turbine rotors and associated blade path components at Ringhals 1, a 1960's vintage English Electric (GEC) unit located near Varobacka, Sweden, and operated by Vattenfall AB. This achieved significant performance improvements and provided improved mechanical features over the original equipment. This paper, discusses design, manufacture, installation, operation and project coordination. The retrofit processes employed for these units can be applied to any potential customers units

  19. Smell of danger: an analysis of LP-gas odorization

    Energy Technology Data Exchange (ETDEWEB)

    Cain, W.S.; Turk, A.

    1985-03-01

    LP-gas derives warning properties from the odorants ethyl mercaptan or thiophane. Laboratory tests have implied that the average person has the ability to smell the odors before leaking LP-gas reaches one-fifth its lower limit of flammability. Generally, however, laboratory tests ignore or discard persons with a poor sense of smell, especially the elderly and persons with certain types of hyposmia. Some persons who apparently can smell the warning agents when directed may otherwise fail to notice or identify them. Elderly men seem particularly vulnerable to instances of incidental anosmia and olfactory agnosia. Psychophysical testing of the warning agents has been rather unsophisticated. There exists neither a standard protocol for testing nor adequate specification of the perceptual properties that might make one warning agent better than another. Without such developments, improvement in warning agents will fail to occur. Possible improvements include increases in concentration, the use of blends to insure more uniform delivery of agent and, to decrease the perceptual vulnerability of relatively insensitive people, use of agents with favorable psychophysical (stimulus-response) functions and use of agents with favorable adaptation characteristics. Even without a change in existing products, it seems advisable to learn more about the vulnerability of LP-gas users and to employ educational means to reduce risks.

  20. Successful Percutaneous Retrieval of an Inferior Vena Cava Filter Migrating to the Right Ventricle in a Bariatric Patient

    International Nuclear Information System (INIS)

    Veerapong, Jula; Wahlgren, Carl Magnus; Jolly, Neeraj; Bassiouny, Hisham

    2008-01-01

    The use of an inferior vena cava filter has an important role in the management of patients who are at high risk for development of pulmonary embolism. Migration is a rare but known complication of inferior vena cava filter placement. We herein describe a case of a prophylactic retrievable vena cava filter migrating to the right ventricle in a bariatric patient. The filter was retrieved percutaneously by transjugular approach and the patient did well postoperatively. A review of the current literature is given.

  1. Right to left shunt as a collateral circulation in a patient with superior vena cava syndrome: a case report

    International Nuclear Information System (INIS)

    Kim, Young Sun; Jeon, Seok Chol; Moon, Won Jin; Choi, Yo Won; Seo, Heung Suk; Hahm, Chang Kok; Park, Choong Ki

    1999-01-01

    In patients with superior vena cava syndrome, the form of the collateral circulatory system which communicates with the inferior vena cava via various systemic veins usually varics. We found an instance of unusual collateral circulation : direct communication between the systemic and pulmonary vein in a woman with superior vena cava syndrome caused by metastatic lymph node enlargement. In this report, we describe the CT and radionuclide venographic findings

  2. Agglomeration Economies and the High-Tech Computer

    OpenAIRE

    Wallace, Nancy E.; Walls, Donald

    2004-01-01

    This paper considers the effects of agglomeration on the production decisions of firms in the high-tech computer cluster. We build upon an alternative definition of the high-tech computer cluster developed by Bardhan et al. (2003) and we exploit a new data source, the National Establishment Time-Series (NETS) Database, to analyze the spatial distribution of firms in this industry. An essential contribution of this research is the recognition that high-tech firms are heterogeneous collections ...

  3. 78 FR 62614 - Guttman Energy, Inc., PBF Holding Company LLC v. Buckeye Pipe Line Company, L.P., Laurel Pipe...

    Science.gov (United States)

    2013-10-22

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. OR14-4-000] Guttman Energy, Inc., PBF Holding Company LLC v. Buckeye Pipe Line Company, L.P., Laurel Pipe Line Company, L.P... complaint against Buckeye Pipe Line Company L.P. and Laurel Pipe Line Company L.P. (Respondents) challenging...

  4. Is there such a thing as Tech Trans?

    DEFF Research Database (Denmark)

    Helms, Niels Henrik

    2009-01-01

    This short paper is an attempt to start a discussion on some basic issues within the concept of Tech Trans especially the relationship between flow and structure within the concept. The background to this paper is first of all an academic interest in the relationship between flow and structure...... explores the concept of Tech Trans, show rooms and innovation systems, and it suggests that the notion of Tech Trans should be defined in the fix point of vertical and horizontal innovation. Finally this paper suggests a mathematical formula for evaluating Tech Trans....

  5. Reconstruction of a total avulsion of the hepatic veins and the suprahepatic inferior vena cava secondary to blunt thoracoabdominal trauma.

    Science.gov (United States)

    Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten

    2011-02-01

    Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.

  6. The Lp_3561 and Lp_3562 enzymes support a functional divergence process in the lipase/esterase toolkit from Lactobacillus plantarum

    Directory of Open Access Journals (Sweden)

    Maria Esteban-Torres

    2016-07-01

    Full Text Available Lactobacillus plantarum species is a good source of esterases since both lipolytic and esterase activities have been described for strains of this species. No fundamental biochemical difference exists among esterases and lipases since both share a common catalytic mechanism. L. plantarum WCFS1 possesses a protein, Lp_3561, which is 44% identical to a previously described lipase, Lp_3562. In contrast to Lp_3562, Lp_3561 was unable to degrade esters possessing a chain length higher than C4 and the triglyceride tributyrin. As in other L. plantarum esterases, the electrostatic potential surface around the active site in Lp_3561 is predicted to be basic, whereas it is essentially neutral in the Lp_3562 lipase. The fact that the genes encoding both proteins were located contiguously in the L. plantarum WCFS1 genome, suggests that they originated by tandem duplication, and therefore are paralogs as new functions have arisen during evolution. The presence of the contiguous lp_3561 and lp_3562 genes was studied among L. plantarum strains. They are located in a 8,903 bp DNA fragment that encodes proteins involved in the catabolism of sialic acid and are predicted to increase bacterial adaptability under certain growth conditions.

  7. CT diagnosis of tumor thrombus of the renal vein and inferior vena cava

    International Nuclear Information System (INIS)

    Masuda, Fujio; Chen, Zuicho; Oishi, Yukihiko; Machida, Toyohei

    1980-01-01

    We used computed tomography (CT) for diagnosis in 4 cases of renal tumor associated with tumor thrombus of the renal vein and inferior vana cava. The results obtained are described below: A total of 4 cases consisting of 3 cases of renal cell carcinoma and one case of squamous cell carcinoma of the renal pelvis, treated at the Jikei University Hospital during the six months period from January to June of 1979, were studied. The affected side was right in 3 cases and left in one case. In all of the former cases the tumor thrombus was extending from the renal vein to the inferior vena cava, while in the latter case it was confined in the renal vein. All these 4 cases received CT together with renal arteriography and inferior venacavography, followed by nephrectomy, and were confirmed of the presence of tumor thrombus in the renal vein and inferior vena cava operatively. CT findings revealed a pronounced enlargement of the renal vein, and tumor thrombus of the renal vein was diagnosed in all of the 4 cases. In 2 of 3 cases in which tumor thrombus extended to the inferior vena cava, the dilated renal vein was found to be connected to the slightly dilated inferior vena cava, while in the remaining one case the outline of the inferior vena cava was obscure, showing no clear dilatation. After contrast enhancement, a filling defect was seen in the inferior vena cava. CT findings of tumor thrombus in the vein indicated a dilatation of the renal vein and inferior vena cava. In addition, a filling defect was found after contrast enhancement, suggesting that CT is helpful as a diagnostic aid. (author)

  8. Retrocaval ureter and anomalies of inferior vena cava

    International Nuclear Information System (INIS)

    Tsubogo, Yoshitaka; Hiraoka, Hisaki; Tonariya, Yoshito; Miyamae, Tatsuya; Fujioka, Mutsumi

    1980-01-01

    We report two cases of retrocaval ureter: one with the usual hook-shaped pattern of the course of ureter (Type 1 according to Kenawi and Williams) and the other with the ureter medially displaced in a large curving fashion without kinking or obstruction. (Type 2). The second case was diagnosed on CT without resorting to any invasive procedure. It can be classified as Type 2 of Kenawi and Williams because of the absence of obstruction and kinking of ureter. The first case is associated with a complicated anomaly of inferior vena cava previously not reported which shows the duplication of infrarenal segment of cava with azygos continuation via the right persistent supracardinal vein. This anomaly is also complicated by the persistent posterior cardinal vein which is continuous with the normal prerenal segment of cava after receiving the right renal vein. This persistent posterior cardinal vein is the cause of retrocaval ureter in this case. It is also stressed that the knowledge of various caval anomalies is important in the interpretation of CT. (author)

  9. Evaluation of Retrievability of the Gunther Tulip Vena Cava Filter

    International Nuclear Information System (INIS)

    Yamagami, Takuji; Kato, Takeharu; Hirota, Tatsuya; Yoshimatsu, Rika; Matsumoto, Tomohiro; Nishimura, Tsunehiko

    2007-01-01

    Purpose. To evaluate the feasibility and safety of withdrawal of a Gunther tulip retrievable vena cava filter (GTF). Methods. Between June 2001 and December 2005, at our institution 86 GTFs were implanted for temporary caval filtration in 59 patients (37 women, 22 men; mean age 59.3 years, range 18-87 years). For GTFs retrieved thereafter, we retrospectively reviewed the following parameters: rate of success in retrieval, degree of trapped thrombus in the filter, and complications during retrieval. Results. Worsening of or new development of pulmonary embolism after filter implantation did not occur in any patient. Of the 86 GTFs implanted, retrieval of 80 was attempted. Among those 80 filters, 77 (96%) were successfully retrieved (with the standard method, n = 72; with the modified method, n = 5) without any complication. The period of implantation of the retrieved filters was 13.4 ± 4.2 days. In the 5 filters that were filled to a height of ≥ 1/4 with trapped thrombus, retrieval was performed after attempts were made to decrease trapped thrombi. In addition, a temporary filter or another GTF was temporarily placed at the cephalad level of the GTF during this removal procedure. Conclusion. GTFs can be retrieved in the majority of cases. Even when encountering situations in which the filter could not be removed using the standard method, withdrawal was possible in a high frequency of cases through various trials using modified methods

  10. Radiographic evaluation of caudal vena cava size in dogs

    International Nuclear Information System (INIS)

    Lehmkuhl, L.B.; Bonagura, J.D.; Biller, D.S.; Hartman, W.M.

    1997-01-01

    Dilation of the caudal vena cava (CVC) on lateral thoracic radiographs is often interpreted as suggestive of right-sided congestive heart failure, To quantitate the clinical utility of evaluating CVC size as an indicator of right-sided heart disease, we compared the ratio of the diameter of the CVC as measured on a left lateral thoracic radiograph to the descending aorta (Ao), length of the thoracic vertebra above the tracheal bifurcation (VL), and width of the right fourth rib (R4) in 35 dogs with right heart disease and 35 control dogs, Each CVC ratio(CVC/Ao, CVC/VL, CVC/R4) was statistically larger in dogs with right heart disease, Response operating characteristic curves and likelihood ratios were used to determine ratios helpful in identifying dogs with right heart disease. A CVC/Ao > 1.50, CVC/VL > 1.30, or CVC/R4 > 3.50 are strongly suggestive of a right-sided heart abnormality in a patient

  11. FinTech Market Development Perspectives

    OpenAIRE

    Kalmykova, Ekaterina Yurievna; Ryabova, Anna

    2016-01-01

    Fast development of technologies has led to emergence of the new market – FinTech – which is very attractive for investors today. By now this market has a great number of different concepts: P2P-crediting, E-wallets, Bitcoins, mPOS-acquiring, T-commerce, mobile banks, etc. Many of these tools have already heavily entered our ordinary life. People can obtain any credits through special services on the Internet from other users without participation of banks, pay by credit card using mobile dev...

  12. Animal experimental study of safety for a self-made vena cava stent-filter

    International Nuclear Information System (INIS)

    Qin Dingwen; Shi Haibin; Liu Sheng; Li Linsun

    2008-01-01

    Objective: To evaluate the safety of a self-made vena cava stent-filter(VCSF)for prevention of pulmonary embolism. Methods: Fusiform unmhrella-like vena cava filter was made of Nitinol wires and stainless steel metal pole, and then ten mongrel dogs were implanted with these self-made filters and divided into 5 groups according to the different periods (2, 3, 4, 5 and 6 w) of filter placement, with 2 dogs in each group. After the VCSFs were placed in inferior vena cava via the right femoral vein approach, the dogs in each group were bred for 2-6 weeks, respectively. The blood flow of inferior vena cava and the position of the filters were inspected by inferior vena-cavography according to the indwelling periods. Finally the metal pole was retrieved via the femoral vein, leaving the VCSF as permanent venousz stent. The feasibility of retrieval and the free state of filter net with the adhering vascular wall were evaluated. Laparotomies were performed to remove the inferior vena cava from the animals for gross and electron microscopic examinations of the inferior vena cava intimal changes of the involved segment. Results: All 10 VCSFs were placed at the right positions of the dogs successfully. Angiography showed patent inferior vena cava without filter thrombosis at 2-6 weeks. There were no tilting and migration of the filter and all the metal poles were successfully retrieved. The superior and inferior extremities of filter nets could be set free with all the filters turning into venous stents. Postmortem displayed retroperitoneal hemorrhage and caval thrombosis. The barbs of the filters penetrated over the caval adventitial coat. Under electron microscope, a thin layer of neointima already covered the braiding net of VCSFs at 2 weeks after the deployment. The tunica intima became slightly thick at 3-4 weeks and with moderate proliferation at 5-6 weeks. Conclusions: The self-made vena cava stent-filter possesses rather long indwelling period according to the

  13. Study of 99Tcm-annexin V distribution in inferior vena cava thrombus models of rabbits

    International Nuclear Information System (INIS)

    Wu Dayong; Zhang Wenyan; Bian Yanzhu; Hu Yujing

    2013-01-01

    To study 99 Tc m -Annexin V distribution in inferior vena cava thrombus models of rabbits and uptake of 99 Tc m -Annexin V in fresh and old venous thrombus. Rabbits (n=15) were randomly grouped into 3 groups (the fresh thrombus group, old thrombus group, and control group). The rabbits of two thrombus groups developed inferior vena cava thrombus models by operations. The control group received sham operation. The fresh thrombus group and control group rabbits were injected 99 Tc m -Annexin V after operating 1 d; the old thrombus group 14 d. After 1 h all rabbits were killed by injecting overdose pentobarbital sodium. The thrombus (or the inferior vena cava about 3 cm below inferior pole of right kidney level in the control group rabbits), blood, thrombus area inferior vena cava, head lateral inferior vena cava (except the control group), thigh muscle, stomach, myocardium, pulmonary, liver, kidney, spleen, bone and small intestine were obtained from all group rabbits. The ex tissue and blood were weighed and measured by a Well-type detector. The percentage of the injected dose per gram of ex tissue (or blood) was calculated by the above data. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and thigh muscle ratios were calculated by percentage of the injected dose per gram of ex tissue (or blood). The test was used to compare the fresh thrombus group and old thrombus group by SPSS 17.0. The percentage of' the injected dose per gram of thrombi (0.01894± 0.002 16% ID/g) in the fresh thrombus group was higher than the old thrombus group (0.00473±0.001 28% ID/g), P<0.05. The thrombus to blood, thrombus area inferior vena cava, head lateral inferior vena cava and muscle ratios (3.42±1.06, 26.32±13.60, 31.23 ±16.00, 111.62±52.23) in the fresh thrombus group were higher than the old thrombus group (0.98±0.09, 5.12±2.01, 6.25±2.38, 21.82±5.93), P<0.05 for all. All the thrombi of the fresh thrombus group were confirmed

  14. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee [Catholic University College of Medicine, Seoul (Korea, Republic of)

    1988-03-15

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  15. Neuroimaging findings in neonates and infants from superior vena cava obstruction after cardiac operation

    International Nuclear Information System (INIS)

    Karmazyn, Boaz; Horev, Gadi; Kornreich, Liora; Dagan, Ovdi; Vidne, Bernado A.

    2002-01-01

    Extraventricular obstructive hydrocephalus may develop after superior vena cava obstruction, an uncommon complication after cardiac surgery.Objective. To describe the neuroimaging findings in neonates and infants with superior vena cava thrombosis after cardiac surgery for congenital heart disease.Materials and methods. Between 1993 and 2001, 333 neonates and infants in our hospital underwent cardiac surgery, of whom 13 (3.9%) subsequently acquired superior vena cava syndrome. Eleven of these 13 children (7 boys, 4 girls) were evaluated by head ultrasound and computed tomography scans.Results. One child had normal findings on head ultrasound, and 10 children had extraventricular obstructive hydrocephalus (EVOH). In 6 children, aggravation of the hydrocephalus was noted up to 11.4 months after cardiac surgery; in 3 of them, the hydrocephalus was shunted to the peritoneum. One child had thrombosis of the dural sinuses, and 1 had hemorrhagic infarction. Two children died during follow-up.Conclusion. EVOH is a common complication of superior vena cava thrombosis, and head ultrasound should be performed in all neonates and infants with superior vena cava thrombosis after cardiac surgery. Long-term follow-up is needed, as the hydrocephalus may worsen even months after surgery. (orig.)

  16. Computed tomographic characteristics of collateral venous pathways in dogs with caudal vena cava obstruction.

    Science.gov (United States)

    Specchi, Swan; d'Anjou, Marc-André; Carmel, Eric Norman; Bertolini, Giovanna

    2014-01-01

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n = 2), portal (n = 2), intermediate (n = 7), and superficial (n = 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector-row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases. © 2014 American College of Veterinary Radiology.

  17. Hepatic Scintigraphic Findings of Budd-Chiari Syndrome due to Inferior Vena Caval Obstruction

    International Nuclear Information System (INIS)

    Kim, Sung Hoon; Chung, Soo Kyo; Byun, Jae Young; Lee, Sung Yong; Shinn, Kyung Sub; Kim, Choon Yul; Bahk, Yong Whee

    1988-01-01

    Budd-Chiari syndrome (BCS) is a rare clinical entity characterized by post-sinusoidal portal hypertension caused by the obstruction to the hepatic vein outflow. The diagnosis is suggested by hepatic scintigraphy and is usually confirmed by hepatic venography, inferior vena cavography and biopsy. The scintigraphic finding of BCS caused by the obstruction of main hepatic vein has been reported to consist typically of hypertrophy of the caudate lobe with increased radionuclide accumulation. Such a typical finding has been accounted for by the fact that the venous outflow from the caudate lobe is preserved when the main hepatic vein is obstructed. But usually, the hepatic venous outflow from the caudate lobe is also obstructed in BCS due to inferior vena caval obstruction. So hepatic scintigraphic findings of BCS due to inferior vena caval obstruction show different findings as compared with the BCS due to hepatic vein obstruction. We evaluate the hepatic scintigrams of the 13 cases of BCS due to inferior vena caval obstruction and review the literatures. The results are as follows: 1) We cannot observe the caudate lobe hypertrophy with increased uptake, which is known as a classic finding in BCS due to hepatic vein obstruction. 2) The most prominent hepatic scintigraphic findings of BCS are nonhomogenous uptake in the liver with extrahepatic uptake in the all cases. 3) We can see cold areas at the superior aspect of right hepatic lobe in 7 cases (54%). This is a useful finding suggesting BCS due to inferior vena caval obstruction.

  18. Sparse Adaptive Channel Estimation Based on lp-Norm-Penalized Affine Projection Algorithm

    Directory of Open Access Journals (Sweden)

    Yingsong Li

    2014-01-01

    Full Text Available We propose an lp-norm-penalized affine projection algorithm (LP-APA for broadband multipath adaptive channel estimations. The proposed LP-APA is realized by incorporating an lp-norm into the cost function of the conventional affine projection algorithm (APA to exploit the sparsity property of the broadband wireless multipath channel, by which the convergence speed and steady-state performance of the APA are significantly improved. The implementation of the LP-APA is equivalent to adding a zero attractor to its iterations. The simulation results, which are obtained from a sparse channel estimation, demonstrate that the proposed LP-APA can efficiently improve channel estimation performance in terms of both the convergence speed and steady-state performance when the channel is exactly sparse.

  19. 2-LP mode few-mode fiber amplifier employing ring-core erbium-doped fiber.

    Science.gov (United States)

    Ono, Hirotaka; Hosokawa, Tsukasa; Ichii, Kentaro; Matsuo, Shoichiro; Nasu, Hitoshi; Yamada, Makoto

    2015-10-19

    A fiber amplifier supporting 2 LP modes that employs a ring-core erbium-doped fiber (RC-EDF) is investigated to reduce differential modal gain (DMG). The inner and outer radii of the ring-core of the RC-EDF are clarified for 2-LP mode operation of the amplifier, and are optimized to reduce the DMG. It is shown that using the overlap integral between the erbium-doped core area and the signal power mode distribution is a good way to optimize the inner and outer radii of the ring-core of the RC-EDF and thus minimize the DMG. A fabricated RC-EDF and a constructed 2-LP mode EDFA are described and a small DMG of around 1 dB is realized for LP01, LP11 and LP21 pumping.

  20. The Debreather and NuTech: A Reply to Kleespies

    Science.gov (United States)

    Ogden, Russel D.

    2010-01-01

    This article responds to Phillip Kleespies's (2010/this issue) commentary on NuTech fieldworkers and their use of the debreather. Non-medical assistance with suicide raises legitimate concerns about accountability, public safety, and care for those who are suffering. Given that suicide is not a crime, an outcome of the NuTech movement may be that…

  1. TechTrends 2010-2015: A Content Analysis

    Science.gov (United States)

    Stauffer, Eric

    2017-01-01

    This study is a content analysis of articles published within the journal "TechTrends" from 2000 to 2015. The study reveals that the publication "TechTrends" has increased the overall number of peer reviewed original papers over the last 6 years. The author describes the proportion of these original papers per volume and…

  2. Ball handling system for tech united soccer robots

    NARCIS (Netherlands)

    Gerrits, K.P.; Molengraft, van de M.J.G.; Hoogendijk, R.; Steinbuch, M.

    2012-01-01

    This pre-master end project is done for team Tech United of Eindhoven University of Technology. The Tech United team is a group of students and employees who design, build and program soccer robots to compete in the RoboCup Middle Size League. RoboCup is a worldwide competition in which two teams of

  3. TechEdSat Nano-Satellite Series Fact Sheet

    Science.gov (United States)

    Murbach, Marcus; Martinez, Andres; Guarneros Luna, Ali

    2014-01-01

    TechEdSat-3p is the second generation in the TechEdSat-X series. The TechEdSat Series uses the CubeSat standards established by the California Polytechnic State University Cal Poly), San Luis Obispo. With typical blocks being constructed from 1-unit (1U 10x10x10 cm) increments, the TechEdSat-3p has a 3U volume with a 30 cm length. The project uniquely pairs advanced university students with NASA researchers in a rapid design-to-flight experience lasting 1-2 semesters.The TechEdSat Nano-Satellite Series provides a rapid platform for testing technologies for future NASA Earth and planetary missions, as well as providing students with an early exposure to flight hardware development and management.

  4. Abdominal wall phlebitis due to Prevotella bivia following renal transplantation in a patient with an occluded inferior vena cava

    NARCIS (Netherlands)

    Janssen, S.; van Donselaar-van der Pant, K. A. M. I.; van der Weerd, N. C.; Develter, W.; Bemelman, F. J.; Grobusch, M. P.; Idu, M. M.; ten Berge, I. J. M.

    2013-01-01

    Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous

  5. Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success

    Energy Technology Data Exchange (ETDEWEB)

    Geisbuesch, Philipp, E-mail: philippgeisbuesch@gmx.de; Benenati, James F.; Pena, Constantino S.; Couvillon, Joseph; Powell, Alex; Gandhi, Ripal; Samuels, Shaun; Uthoff, Heiko [Baptist Cardiac and Vascular Institute, Division of Vascular and Interventional Radiology (United States)

    2012-10-15

    Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11-95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients had an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.

  6. Percutaneous treatment of superior vena cava syndrome using metallic stents

    International Nuclear Information System (INIS)

    De Gregorio Ariza, Miguel Angel; Gimeno, Maria Jose; Alfonso, Eduardo; Mainar, Antonio; Medrano, Joaquin; Lopez-Marin, Paloma; Gamboa, Pablo; Tobio, Ricardo; Herrera, Marcos

    2003-01-01

    The purpose of this study was to evaluate the results of treatment of superior vena cava syndrome (SVCS) in patients with benign and malignant disease using expandable metallic stent. From January 1995 to April 2000, 87 expandable stents were implanted in 82 patients (59 men, 23 women; mean age 57.8 years, age range 39-79 years) for the treatment of SVCS. The SVCS was defined as symptomatic bilateral obstruction of venous drainage from head, neck and upper extremities. In 68 patients SVCS was due to malignant neoplasia, and in 14 cases it was due to benign aetiology. All patients were treated with expandable stent. We implanted 81 Wallstent prostheses and 6 Palmaz stents. Adjuvant thrombolysis was applied in 12 patients who required fibrinolysis. After recanalization, the stent was implanted in all cases in SVC (infra- or supra-azygos vein). All patients were treated with heparin of low molecular weight (HBPM) during 6 months. Patency was analyzed according to clinical symptoms and Doppler US or venograms exploration. Technical success was observed in all cases. Clinical success was reached in 78 of 82 patients (95.1%) (absence of symptoms in 2 or 3 days). Four patients suffered immediate thrombosis which required fibrinolitic treatment with a new prosthesis placement in 1 case. The follow-up for the malignant process was of 7.1 months (range 1-39 months) and in benign cases was 31.2 months (range 11-61 months). Sixty-two (91.1%) patients with malignancy died without SVCS symptomatology. All the patients with benign pathology are alive. Clinical primary patency in malignant cases was 87% with assisted patency of 96.2%. Endovascular therapy using metallic stent and thrombolysis is a successful method to treat SVCS due to benign or malignant aetiology. (orig.)

  7. Retrievable Inferior Vena Cava Filters: Factors that Affect Retrieval Success

    International Nuclear Information System (INIS)

    Geisbüsch, Philipp; Benenati, James F.; Peña, Constantino S.; Couvillon, Joseph; Powell, Alex; Gandhi, Ripal; Samuels, Shaun; Uthoff, Heiko

    2012-01-01

    Purpose: To report and analyze the indications, procedural success, and complications of retrievable inferior vena cava filters (rIVCF) placement and to identify parameters that influence retrieval attempt and failure. Methods: Between January 2005 and December 2010, a total of 200 patients (80 men, median age 67 years, range 11–95 years) received a rIVCF with the clinical possibility that it could be removed. All patients with rIVCF were prospectively entered into a database and followed until retrieval or a decision not to retrieve the filter was made. A retrospective analysis of this database was performed. Results: Sixty-one percent of patients had an accepted indication for filter placement; 39% of patients had a relative indication. There was a tendency toward a higher retrieval rate in patients with relative indications (40% vs. 55%, P = 0.076). Filter placement was technically successful in all patients, with no procedure-related mortality. The retrieval rate was 53%. Patient age of >80 years (odds ratio [OR] 0.056, P > 0.0001) and presence of malignancy (OR 0.303, P = 0.003) was associated with a significantly reduced probability for attempted retrieval. Retrieval failure occurred in 7% (6 of 91) of all retrieval attempts. A time interval of > 90 days between implantation and attempted retrieval was associated with retrieval failure (OR 19.8, P = 0.009). Conclusions: Patient age >80 years and a history of malignancy are predictors of a reduced probability for retrieval attempt. The rate of retrieval failure is low and seems to be associated with a time interval of >90 days between filter placement and retrieval.

  8. Vena Cava Responsiveness to Controlled Isovolumetric Respiratory Efforts.

    Science.gov (United States)

    Folino, Anna; Benzo, Marco; Pasquero, Paolo; Laguzzi, Andrea; Mesin, Luca; Messere, Alessandro; Porta, Massimo; Roatta, Silvestro

    2017-10-01

    Respirophasic variation of inferior vena cava (IVC) size is affected by large variability with spontaneous breathing. This study aims at characterizing the dependence of IVC size on controlled changes in intrathoracic pressure. Ten healthy subjects, in supine position, performed controlled isovolumetric respiratory efforts at functional residual capacity, attaining positive (5, 10, and 15 mmHg) and negative (-5, -10, and -15 mmHg) alveolar pressure levels. The isovolumetric constraint implies that equivalent changes are exhibited by alveolar and intrathoracic pressures during respiratory tasks. The IVC cross-sectional area equal to 2.88 ± 0.43 cm 2 at baseline (alveolar pressure = 0 mmHg) was progressively decreased by both expiratory and inspiratory efforts of increasing strength, with diaphragmatic efforts producing larger effects than thoracic ones: -55 ± 15% decrease, at +15 mmHg of alveolar pressure (P < .01), -80 ± 33 ± 12% at -15 mmHg diaphragmatic (P < .01), -33 ± 12% at -15 mmHg thoracic. Significant IVC changes in size (P < .01) and pulsatility (P < .05), along with non significant reduction in the response to respiratory efforts, were also observed during the first 30 minutes of supine rest, detecting an increase in vascular filling, and taking place after switching from the standing to the supine position. This study quantified the dependence of the IVC cross-sectional area on controlled intrathoracic pressure changes and evidenced the stronger influence of diaphragmatic over thoracic activity. Individual variability in thoracic/diaphragmatic respiratory pattern should be considered in the interpretation of the respirophasic modulations of IVC size. © 2017 by the American Institute of Ultrasound in Medicine.

  9. Inferior vena cava segmentation with parameter propagation and graph cut.

    Science.gov (United States)

    Yan, Zixu; Chen, Feng; Wu, Fa; Kong, Dexing

    2017-09-01

    The inferior vena cava (IVC) is one of the vital veins inside the human body. Accurate segmentation of the IVC from contrast-enhanced CT images is of great importance. This extraction not only helps the physician understand its quantitative features such as blood flow and volume, but also it is helpful during the hepatic preoperative planning. However, manual delineation of the IVC is time-consuming and poorly reproducible. In this paper, we propose a novel method to segment the IVC with minimal user interaction. The proposed method performs the segmentation block by block between user-specified beginning and end masks. At each stage, the proposed method builds the segmentation model based on information from image regional appearances, image boundaries, and a prior shape. The intensity range and the prior shape for this segmentation model are estimated based on the segmentation result from the last block, or from user- specified beginning mask if at first stage. Then, the proposed method minimizes the energy function and generates the segmentation result for current block using graph cut. Finally, a backward tracking step from the end of the IVC is performed if necessary. We have tested our method on 20 clinical datasets and compared our method to three other vessel extraction approaches. The evaluation was performed using three quantitative metrics: the Dice coefficient (Dice), the mean symmetric distance (MSD), and the Hausdorff distance (MaxD). The proposed method has achieved a Dice of [Formula: see text], an MSD of [Formula: see text] mm, and a MaxD of [Formula: see text] mm, respectively, in our experiments. The proposed approach can achieve a sound performance with a relatively low computational cost and a minimal user interaction. The proposed algorithm has high potential to be applied for the clinical applications in the future.

  10. Diagnosis of tricuspid insufficiency by Doppler flowmetry in the inferior vena cava

    International Nuclear Information System (INIS)

    Smith, H.J.

    1986-01-01

    Eighty-five patients subjected to routine heart catheterization were examined with duplex scanning of the inferior vena cava. Adequate Doppler recordings and a right ventricular angiography were obtained in 79 of them. Tricuspid insufficiency was found to be present in 34 patients at angiography and in 24 at duplex examination. No false positive Doppler diagnoses of tricuspid insufficiency occurred. The possibility of false positive angiographic diagnoses is discussed. A high correlation was found between percentage reversed flow in the inferior vena cava during ventricular systole and degree of angiographic tricuspid insufficiency. It is concluded that duplex scanning of the inferior vena cava seems to be a good alternative to angiography in the diagnosis and quantification of tricuspid insufficiency. (orig.)

  11. Patent abdominal subcutaneous veins caused by congenital absence of the inferior vena cava: a case report

    Directory of Open Access Journals (Sweden)

    Lipp Rainer W

    2010-07-01

    Full Text Available Abstract Introduction Patent paraumbilical and abdominal subcutaneous veins are found frequently as collaterals in patients due to portal hypertension mainly in liver cirrhosis. Case presentation For evaluation of portal hypertension in a 72-year-old Caucasian man without liver cirrhosis, magnetic resonance imaging with gadolinium contrast-enhancement was performed and demonstrated a missing inferior vena cava. A blood return from the lower extremities was shown through enlarged collateral veins of the abdominal wall, vena azygos and hemiazygos continuation, and multiple liver veins emptying into the right cardiac atrium. We describe a rare case of abdominal subcutaneous wall veins as collaterals caused by a congenitally absent infrarenal inferior vena cava with preservation of a hypoplastic suprarenal segment. Conclusion Knowledge of these congenital variations can be of clinical importance and it is imperative for the reporting radiologist to identify these anomalies as they can have a significant impact on the clinical management of the patient.

  12. Unusual caudal vena cava thrombosis in a cow, secondary to Trueperella (Arcanobacterium pyogenes infection

    Directory of Open Access Journals (Sweden)

    Rodrigo Garcia Motta

    Full Text Available Abstract: The caudal vena cava thrombosis, or pulmonary thromboembolism, in cattle is correlated with lactic acidosis, caused by diets rich in grains and highly fermentable, associated or not to septic situations, used in feedlots of beef or high-producing dairy cattle. This paper reports an unusual caudal vena cava thrombosis in a cow, secondary to Trueperella (Arcanobacterium pyogenes infection, resulting in reduced milk production, anorexia, pale mucous membranes, ruminal atony, sternal decubitus and autoauscultation position. The heart was enlarged at necropsy, presence of clots distributed along the thoracic cavity, adherence between lung and pleura, abscesses, emphysema, petechiae, suffusions and ecchymosis in lungs, thickening of the caudal vena cava wall, hepatomegaly with chronic passive congestion ("nutmeg" aspect, and rumenitis. In lab, the actinomycete Trueperella (Arcanobacterium pyogenes was isolated from liver and lung samples, probably resulting through dissemination of the bacteria of the rumen content, what reaffirms the opportunistic behavior of this actinomycete.

  13. Segmental variants of the inferior vena cava - typical findings correlated with embryological development for differential diagnosis; Segmentale Varianten der Vena cava inferior - Erscheinungsbild mit embryologischer Korrelation in Abgrenzung zum sekundaeren Vena-cava-Verschluss

    Energy Technology Data Exchange (ETDEWEB)

    Meyer, D.R. [Abt. fuer Radiologie, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany); Inst. fuer Radiologie und Nuklearmedizin, Krankenhaus am Urban, Akademisches Lehrkrankenhaus der Freien Univ. Berlin (Germany); Huggle, H.; Hueppe, T.; Friedrich, M. [Inst. fuer Radiologie und Nuklearmedizin, Krankenhaus am Urban, Akademisches Lehrkrankenhaus der Freien Univ. Berlin (Germany); Andresen, R. [Abt. fuer Radiologie, Guestrower Krankenhaus, Akademisches Lehrkrankenhaus der Univ. Rostock (Germany)

    2001-07-01

    The vast variability of the overall rare congenital anomalies of the inferior vena cava (IVC) are mostly detected by accident through different imaging modalities. These cannot be classed as pathological findings, and should not be confused with lymphomas and has to differ from secondary collateral venous pathways. Based on 656 CT examinations 10.5% known forms of IVC anomalies were found. According to the embryological development three main groups of IVC variants could be nosologically classified: agenesis of the suprarenal IVC, anomalies of the pars renalis and anomalies of the infrarenal IVC. Additionally three unusual anomaly complexes were found. For the understanding details of the embryology based on a simplified depiction are presented. (orig.) [German] Die grosse Variabilitaet der als insgesamt selten anzusehenden angeborenen Venenanomalien der Vena cava inferior werden meist zufaellig durch verschiedene bildgebende Untersuchungsverfahren entdeckt. Diese koennen nicht als Pathologien des venoesen Systems klassifiziert werden und sollten nicht mit Lymphomen oder sekundaeren venoesen Kollateralen verwechselt werden. Basierend auf 656 CT-Untersuchungen fanden sich insgesamt 10,5% an bekannten Vena cava inferior (VCI) Anomalien. Unter Beruecksichtigung der embryologischen Entwicklung konnten drei Hauptgruppen an VCI-Varianten nosologisch differenziert werden: Agenesie der suprarenalen VCI, Anomalien der Pars renalis und Anomalien der infrarenalen VCI. Zusaetzlich fanden sich drei ungewoehnliche Anomaliekomplexe. Fuer das Verstaendnis der VCI-Varianten wird eine schematisierte Embryologie praesentiert. (orig.)

  14. Training Lp norm multiple kernel learning in the primal.

    Science.gov (United States)

    Liang, Zhizheng; Xia, Shixiong; Zhou, Yong; Zhang, Lei

    2013-10-01

    Some multiple kernel learning (MKL) models are usually solved by utilizing the alternating optimization method where one alternately solves SVMs in the dual and updates kernel weights. Since the dual and primal optimization can achieve the same aim, it is valuable in exploring how to perform Lp norm MKL in the primal. In this paper, we propose an Lp norm multiple kernel learning algorithm in the primal where we resort to the alternating optimization method: one cycle for solving SVMs in the primal by using the preconditioned conjugate gradient method and other cycle for learning the kernel weights. It is interesting to note that the kernel weights in our method can obtain analytical solutions. Most importantly, the proposed method is well suited for the manifold regularization framework in the primal since solving LapSVMs in the primal is much more effective than solving LapSVMs in the dual. In addition, we also carry out theoretical analysis for multiple kernel learning in the primal in terms of the empirical Rademacher complexity. It is found that optimizing the empirical Rademacher complexity may obtain a type of kernel weights. The experiments on some datasets are carried out to demonstrate the feasibility and effectiveness of the proposed method. Copyright © 2013 Elsevier Ltd. All rights reserved.

  15. Percutaneous retrieval of a vena cava filter from the right atrium: case report

    International Nuclear Information System (INIS)

    Rasuli, P.; Mehran, R.; French, G.; Turek, M.; Lalonde, K.A.; Cardinal, P.

    2000-01-01

    Migration of vena cava filters can occur spontaneously, but it can also occur as a result of entanglement of the filter with a guidewire, particularly during 'blind' (unguided) insertion of a central venous line. When a filter migrates to the heart, traditional practice has been either to leave the filter in place or to remove it surgically by means of open heart surgery and cardiopulmonary bypass. We found only 6 reports of successful percutaneous retrieval or repositioning of a vena cava filter (Table 1). We describe a new interventional technique for retrieving a filter from the right atrium and a novel endosurgical method for removing a filter from the innominate vein. (author)

  16. Intracranial hemorrhage due to intracranial hypertension caused by the superior vena cava syndrome

    DEFF Research Database (Denmark)

    Bartek, Jiri; Abedi-Valugerdi, Golbarg; Liska, Jan

    2013-01-01

    We report a patient with intracranial hemorrhage secondary to venous hypertension as a result of a giant aortic pseudoaneurysm that compressed the superior vena cava and caused obstruction of the venous return from the brain. To our knowledge, this is the first patient reported to have...... an intracranial hemorrhage secondary to a superior vena cava syndrome. The condition appears to be caused by a reversible transient rise in intracranial pressure, as a result of compression of the venous return from the brain. Treatment consisted of surgery for the aortic pseudoaneurysm, which led...

  17. Gianturco expandable wire stents for treatment of superior vena cava syndrome secondary to lung carcinoma

    International Nuclear Information System (INIS)

    Rosch, J.; Bedell, J.; Putnam, J.; Antonovic, R.; Uchida, B.

    1986-01-01

    Two patients with superior vena cava syndrome (SVCS) secondary to lung carcinoma which recurred after maximum-dose radiation therapy were treated with placement of modified Gianturco expandable wire stents constructed in the authors' research laboratory. Symptoms of SVCS disappeared in 24 hours after stent placement, and the patients remained asymptomatic to their last follow-up, 2 1/2 months after the procedure (to the submission of this abstract). Both stents were widely patent at that time on superior vena cavograms and draining well the head, neck, and upper extremity circulation to the right atrium

  18. Outcome of prolonged acute vena cava occlusion after iatrogenic transection and repair in a dog.

    Science.gov (United States)

    Halwagi, Marie-Chantal; Crawford, Evan; Hoddinott, Katie; Oblak, Michelle L

    2017-08-01

    A 12-year-old castrated male Airedale terrier dog was diagnosed with a hepatocellular carcinoma in the right medial liver lobe. During tumor resection, inadvertent stapling and transection of the caudal vena cava occurred. Complete caval occlusion was required for 18 minutes and primary anastomosis was completed. The dog received 2 blood transfusions and developed mild pelvic limb edema after surgery. Computed tomography evaluation 9 months after surgery showed collateral circulation and suspected stricture of the vena cava with an absence of clinical effect. The dog remained alive and asymptomatic more than 1 year after surgery.

  19. Hepatic Veins and Inferior Vena Cava Thrombosis in a Child Treated by Transjugular Intrahepatic Portosystemic Shunt

    International Nuclear Information System (INIS)

    Carnevale, Francisco Cesar; Santos, Aline Cristine Barbosa; Tannuri, Uenis; Cerri, Giovanni Guido

    2010-01-01

    We report the case of a 9-year-old boy with portal hypertension, due to Budd-Chiari syndrome, and retrohepatic inferior vena cava thrombosis, submitted to a transjugular intrahepatic portosystemic shunt (TIPS) by connecting the suprahepatic segment of the inferior vena cava directly to the portal vein. After 3 months, the withdrawal of anticoagulants promoted the thrombosis of the TIPS. At TIPS revision, thrombosis of the TIPS and the main portal vein and clots at the splenic and the superior mesenteric veins were found. Successful angiography treatment was performed by thrombolysis and balloon angioplasty of a severe stenosis at the distal edge of the stent.

  20. AegeanMarTech project: General Introduction

    Science.gov (United States)

    Psarra, S.; Zervakis, V.; Karageorgis, A. P.

    2017-10-01

    This issue of "Continental Shelf Research" is dedicated to the study of processes potentially responsible for the relatively high productivity of the North Aegean Sea in comparison to other regions of the Eastern Mediterranean. This region, one of the most important fishing grounds in the eastern Mediterranean, is characterized by: i) the inflow of mesotrophic waters of Black Sea (BSW) origin into the North Aegean and their interaction with the more saline Levantine waters (LW); and ii) the wind-generated coastal upwelling occurring every summer in the eastern Aegean. The study of these two natural fertilization mechanisms has been the major aim of the AegeanMarTech project ("Technological and oceanographic cooperation Network for the Study of mechanisms fertilizing the North-East Aegean Sea").

  1. 77 FR 26588 - In the Matter of Recycle Tech, Inc.; Order of Suspension of Trading

    Science.gov (United States)

    2012-05-04

    ... SECURITIES AND EXCHANGE COMMISSION [File No. 500-1] In the Matter of Recycle Tech, Inc.; Order of... of current and accurate information concerning the securities of Recycle Tech, Inc. (``Recycle Tech... protection of investors require a suspension of trading in the securities of Recycle Tech. Therefore, it is...

  2. Fee-based services in sci-tech libraries

    CERN Document Server

    Mount, Ellis

    2013-01-01

    This timely and important book explores how fee-based services have developed in various types of sci-tech libraries. The authoritative contributors focus on the current changing financial aspects of the sci-tech library operation and clarify for the reader how these changes have brought about conditions in which traditional methods of funding are no longer adequate. What new options are open and how they are best being applied in today's sci-tech libraries is fully and clearly explained and illustrated. Topics explored include cost allocation and cost recovery, fees for computer searching, an

  3. LP (a) levels and apo (a) phenotypes in urban black South African ...

    African Journals Online (AJOL)

    300 U/I), intermediate (300 - 700 UII) and high (> 700 UII) plasma Lp (a) ... Tygerberg Hospital, Tygerberg, W Cape ... up to 200-fold difference in Lp (a) concentrations.' In addition, ethnic .... An interesting observation was the large number of phenotypes, Le. ... sample of black Americans with a high-resolution SOS- agarose ...

  4. 76 FR 25229 - Special Conditions: Gulfstream Aerospace LP (GALP) Model G250 Airplane, Dynamic Test Requirements...

    Science.gov (United States)

    2011-05-04

    ... Memorandum ``Side-Facing Seats on Transport Category Airplanes'' and draft Issue Paper ``Dynamic Test...; Special Conditions No. 25-425-SC] Special Conditions: Gulfstream Aerospace LP (GALP) Model G250 Airplane... are issued for the Gulfstream Aerospace LP (GALP) model G250 airplane. This airplane will have a novel...

  5. 76 FR 45246 - Tesoro Refining and Marketing Company v. SFPP, L.P.; Notice of Complaint

    Science.gov (United States)

    2011-07-28

    ... and Marketing Company v. SFPP, L.P.; Notice of Complaint Take notice that on July 20, 2011, pursuant...), Tesoro Refining and Marketing Company (Tesoro) filed a formal complaint against SFPP, L.P. (SFPP). Tesoro... notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service...

  6. 75 FR 35017 - Brookfield Energy Marketing LP; Supplemental Notice That Initial Market-Based Rate Filing...

    Science.gov (United States)

    2010-06-21

    ... Energy Marketing LP; Supplemental Notice That Initial Market-Based Rate Filing Includes Request for... proceeding of Brookfield Energy Marketing LP's application for market-based rate authority, with an... protests and interventions in lieu of paper, using the FERC Online links at http://www.ferc.gov . To...

  7. 77 FR 71585 - Brookfield Energy Marketing LP v. ISO New England Inc.; Notice of Complaint

    Science.gov (United States)

    2012-12-03

    ... Energy Marketing LP v. ISO New England Inc.; Notice of Complaint Take notice that on November 21, 2012...), Brookfield Energy Marketing LP (Complainant) filed a formal complaint against ISO New England Inc... notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service...

  8. 76 FR 45247 - Tesoro Refining and Marketing Company v. SFPP, L.P.; Notice of Complaint

    Science.gov (United States)

    2011-07-28

    ... Refining and Marketing Company v. SFPP, L.P.; Notice of Complaint Take notice that on July 20, 2011... Marketing Company (Complainant) filed a formal complaint against SFPP L.P. (SFPP or Respondent) alleging... with any FERC Online service, please e-mail [email protected] , or call (866) 208-3676 (toll...

  9. 77 FR 28375 - Eagle Rock Desoto Pipeline, L.P.; Notice of Petition for Rate Approval

    Science.gov (United States)

    2012-05-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-25-000] Eagle Rock Desoto Pipeline, L.P.; Notice of Petition for Rate Approval Take notice that on May 1, 2012, Eagle Rock Desoto Pipeline, L.P. (Desoto) filed a Rate Election pursuant to 284.123(b)(1) of the Commissions...

  10. 78 FR 11639 - Houston Pipe Line Company LP; Notice of Petition for Rate Approval

    Science.gov (United States)

    2013-02-19

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR13-31-000] Houston Pipe Line Company LP; Notice of Petition for Rate Approval Take notice that on February 1, 2013, Houston Pipe Line Company LP (HPL) filed for approval of rates for transportation service pursuant to section...

  11. 78 FR 69078 - Houston Pipe Line Company LP; Notice of Application

    Science.gov (United States)

    2013-11-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-13-000] Houston Pipe Line Company LP; Notice of Application Take notice that on October 28, 2013, Houston Pipe Line Company LP (HPL), 1300 Main Street, Houston, Texas 77002, filed an application in Docket No. CP14-13-000...

  12. 77 FR 44113 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2012-07-27

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Aerospace LP (Type Certificate previously held by Israel Aircraft Industries, Ltd.) Model Gulfstream G150... to the manufacturer. This action was prompted by a report from the Civil Aviation Authority of Israel...

  13. 77 FR 64767 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2012-10-23

    ... Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Airplanes AGENCY... airworthiness directive (AD) for certain Gulfstream Aerospace LP (Type Certificate previously held by Israel... Certificate previously held by Israel Aircraft Industries, Ltd.) Model Galaxy and Gulfstream 200 airplanes...

  14. 75 FR 28485 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2010-05-21

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.): Amendment 39... previously held by Israel Aircraft Industries, Ltd.) Model Gulfstream 100 airplanes; and Model Astra SPX and...

  15. 76 FR 81360 - Special Conditions: Gulfstream Aerospace LP (GALP) Model G280 Airplane, Operation Without Normal...

    Science.gov (United States)

    2011-12-28

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 25 [Docket No. FAA-2011-1172: Special Conditions No. 25-453-SC] Special Conditions: Gulfstream Aerospace LP (GALP) Model G280... Aerospace LP (GALP) Model G280 airplane. This airplane will have a novel or unusual design feature...

  16. 76 FR 66660 - Special Conditions: Gulfstream Aerospace LP (GALP) Model G280 Airplane, Operation Without Normal...

    Science.gov (United States)

    2011-10-27

    ... DEPARTMENT OF TRANSPORTATION Federal Aviation Administration 14 CFR Part 25 [Docket No. FAA-2011-1172: Notice No. 25-11-17-SC] Special Conditions: Gulfstream Aerospace LP (GALP) Model G280 Airplane... Aerospace LP (GALP) Model G280 airplane. This airplane will have a novel or unusual design feature...

  17. 76 FR 29234 - Texas Eastern Transmission, LP; Notice of Request Under Blanket Authorization

    Science.gov (United States)

    2011-05-20

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-477-000] Texas Eastern Transmission, LP; Notice of Request Under Blanket Authorization Take notice that on May 10, 2011 Texas Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed in Docket No. CP11-477-000...

  18. 76 FR 12103 - Erie Boulevard Hydropower, L.P; Notice of Settlement Agreement and Soliciting Comments

    Science.gov (United States)

    2011-03-04

    ... Hydropower, L.P; Notice of Settlement Agreement and Soliciting Comments Take notice that the following... Boulevard Hydropower, L.P. e. Location: The existing multi-development project is located on the Oswegatchie... 791 (a)-825(r) h. Applicant Contact: Daniel Daoust, Erie Boulevard Hydropower, 33 West 1st Street...

  19. Outcome of inferior vena cava and noncaval venous leiomyosarcomas.

    Science.gov (United States)

    Illuminati, Giulio; Pizzardi, Giulia; Calio', Francesco; Pacilè, Maria Antonietta; Masci, Federica; Vietri, Francesco

    2016-02-01

    Leiomyosarcoma (LMS) is a rare tumor arising from the smooth muscle cells of arteries and veins. LMS may affect both the inferior vena cava (IVC) and non-IVC veins. Because of its rarity, the experience with the outcome of the disease originating from the IVC compared with that with non-IVC offspring is overall limited. In this study, we compared the clinical features and outcomes after operative resection of IVC and non-IVC LMS to detect possible significant differences that could affect treatment and prognosis. Twenty-seven patients undergoing operative resection of a venous LMS at a single tertiary care center and one secondary care hospital were reviewed retrospectively and divided into 2 groups: IVC-LMS (Group A, n = 18) and non-IVC LMS (Group B, n = 9). As primary end points, postoperative mortality and morbidity, disease-specific survival and, if applicable, patency of venous reconstruction were considered. Bivariate differences were compared with the χ(2) test. Disease-specific survival was expressed by a life-table analysis and compared using the log-rank test. No postoperative mortality was observed in either group. Postoperative morbidity was 28% in group A and 11% in group B (P = .33). The mean duration of follow-up was 60 months (range, 13-140). Disease-specific survival was 60% in group A and 75% in group B at 3 years (P = .48), and it was 54% in group A and 62% in group B at 5 years (P = .63). Seven grafts were occluded in group A (39%) and 1of 3 were occluded in group B (33%) (P = .85). IVC and non-IVC LMS exhibit similar outcomes in terms of postoperative course and survival. Operative resection associated with vascular reconstruction, if applicable, eventually followed by radiation and chemotherapy may be curative and is associated with good functional results. Copyright © 2016 Elsevier Inc. All rights reserved.

  20. Implementing and analyzing the multi-threaded LP-inference

    Science.gov (United States)

    Bolotova, S. Yu; Trofimenko, E. V.; Leschinskaya, M. V.

    2018-03-01

    The logical production equations provide new possibilities for the backward inference optimization in intelligent production-type systems. The strategy of a relevant backward inference is aimed at minimization of a number of queries to external information source (either to a database or an interactive user). The idea of the method is based on the computing of initial preimages set and searching for the true preimage. The execution of each stage can be organized independently and in parallel and the actual work at a given stage can also be distributed between parallel computers. This paper is devoted to the parallel algorithms of the relevant inference based on the advanced scheme of the parallel computations “pipeline” which allows to increase the degree of parallelism. The author also provides some details of the LP-structures implementation.

  1. Infimal Convolution Regularisation Functionals of BV and Lp Spaces

    KAUST Repository

    Burger, Martin

    2016-02-03

    We study a general class of infimal convolution type regularisation functionals suitable for applications in image processing. These functionals incorporate a combination of the total variation seminorm and Lp norms. A unified well-posedness analysis is presented and a detailed study of the one-dimensional model is performed, by computing exact solutions for the corresponding denoising problem and the case p=2. Furthermore, the dependency of the regularisation properties of this infimal convolution approach to the choice of p is studied. It turns out that in the case p=2 this regulariser is equivalent to the Huber-type variant of total variation regularisation. We provide numerical examples for image decomposition as well as for image denoising. We show that our model is capable of eliminating the staircasing effect, a well-known disadvantage of total variation regularisation. Moreover as p increases we obtain almost piecewise affine reconstructions, leading also to a better preservation of hat-like structures.

  2. Effect of dissolved oxygen on SCC of LP turbine steel

    International Nuclear Information System (INIS)

    Maeng, W. Y.; Lee, J. H.; Kim, W. C.

    2002-01-01

    Slow Strain Rate Tests (SSRT) were carried out to investigate the effect of dissolved oxygen on Stress Corrosion Cracking (SCC) susceptibility of 3.5NiCrMoV steels used in discs of Low-Pressure (LP) steam turbines in electric power generating plants. The influence of dissolved oxygen on cracking in water was studied; for this purpose, specimens were strained to fracture at 150 .deg. C in water environments with various amounts of dissolved oxygen. The maximum elongation of the turbine steel decreased with increasing dissolved oxygen. Dissolved oxygen significantly affected the SCC susceptibility of turbine steel in water. The increase of the SCC susceptibility of the turbine steel in a higher dissolved oxygen environment is due to the non protectiveness of the oxide layer of the turbine steel surface and the increase of corrosion current

  3. Thrombosis caused by polyurethane double-lumen subclavian superior vena cava catheter and hemodialysis

    DEFF Research Database (Denmark)

    Wanscher, Maria Rørbæk; Frifelt, J J; Smith-Sivertsen, C

    1988-01-01

    During an 18-month period, 82 consecutive patients (37 women and 45 men), with a mean age of 50 yr (range 15 to 74), underwent hemodialysis with 91 polyurethane double-lumen subclavian superior vena cava catheters inserted via the right subclavian vein. Upon catheter removal, venograms were...

  4. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    International Nuclear Information System (INIS)

    Currarino, G.; Stannard, M.W.; Texas Univ., Dallas, TX; Kolni, H.

    1991-01-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.)

  5. An elusive persistent left superior vena cava draining into left atrium

    NARCIS (Netherlands)

    A. Soward; F.J. ten Cate (Folkert); P.M. Fioretti (Paolo); P.W.J.C. Serruys (Patrick); J.R.T.C. Roelandt (Jos)

    1986-01-01

    textabstractA case report of a persistent left superior vena cava draining into left atrium with a fibromuscular left ventricular outflow tract obstruction and a small atrial septal defect. The anomalous vessel escaped detection during two right and left heart catheterizations from the right arm and

  6. Prenatal diagnosis of long QT syndrome with the superior vena cava-aorta Doppler approach.

    Science.gov (United States)

    Chabaneix, Julie; Andelfinger, Gregor; Fournier, Anne; Fouron, Jean-Claude; Raboisson, Marie-Josée

    2012-10-01

    We describe a fetus at 36 weeks with long QT syndrome presenting with variable types of atrioventricular blocks, ventricular premature beats, and torsades de pointes. All these diagnoses were made with the superior vena cava-aorta Doppler approach and confirmed with postnatal electrocardiography. Copyright © 2012 Mosby, Inc. All rights reserved.

  7. Bird's Nest Filter Causing Symptomatic Hydronephrosis Following Transmural Penetration of the Inferior Vena Cava

    International Nuclear Information System (INIS)

    Stacey, C.S.; Manhire, A.R.; Rose, D.H.; Bishop, M.C.

    2004-01-01

    We report a case of symptomatic hydronephrosis caused by transcaval penetration of a Bird's Nest filter. Perforation of the wall of the inferior vena cava (IVC) following insertion of a caval filter is a well-recognized complication. Whilst two cases of hydronephrosis have been described with Greenfield filters, no case involving a Bird's Nest filter has been reported previously

  8. Transection of the inferior vena cava from blunt thoracic trauma: case reports.

    Science.gov (United States)

    Peitzman, A B; Udekwu, A O; Pevec, W; Albrink, M

    1989-04-01

    Blunt thoracic trauma is a frequent cause of death in multiple trauma victims. Myocardial rupture may occur in up to 65% of patients who die with thoracic injuries. Two cases are presented with intrapericardial transection of the inferior vena cava, pericardial rupture, and myocardial rupture from blunt thoracic trauma. Both patients died.

  9. Umbilical vein draining into the inferior vena cava via the internal iliac vein, bypassing the liver

    Energy Technology Data Exchange (ETDEWEB)

    Currarino, G.; Stannard, M.W. (Children' s Medical Center, Dallas, TX (United States). Dept. of Radiology Texas Univ., Dallas, TX (United States). Southwestern Medical Center); Kolni, H. (Methodist Hospital, Dallas, TX (United States). Dept. of Pediatrics)

    1991-05-01

    This is the third report of an anomalous umbilical vein draining ectopically in a left pelvic vein, probably the left internal iliac, and through the inferior vena cava into the right atrium. The anomaly was encountered in a newborn infant with nonimmune hydrops fetalis, hypertrophic cardiomyopathy, multiorgan failure and possibly Noonan Syndrome. (orig.).

  10. Deep venous thrombosis and agenesis of the intrahepatic segment of inferior vena cava

    International Nuclear Information System (INIS)

    Velasco, J.; Fernandez, M.M.; Manzanares, R.; Hernando, A.

    1997-01-01

    We present a case of agenesis of the intrahepatic segment of inferior vena cava (IVC) with drainage through the azygos and hemiazygos systems. The presenting sign was deep venous thrombosis (DVT) in both lower extremities. The different imaging studies led to the diagnosis of both the congenital and acquired venous abnormalities, which are discussed. (Author) 14 refs

  11. The clinical application of the implantation of retrievable filters in superior vena cava

    International Nuclear Information System (INIS)

    Tian Yulong; Zhang Xitong; Hong Duo

    2011-01-01

    Objective: To investigate the safety of the placement of Tulip retrievable filter in superior vena cava and to discuss the prevention of pulmonary embolism (PE). Methods: Implantation of Tulip retrievable filter in superior vena cava was performed in ten patients (6 males and 4 females, aged 42-60 years) with acute or subacute deep venous thrombosis in upper extremity or cephalo-cervical region. After the placement of filter, the local via-catheter thrombolysis was conducted. The clinical results, such as the improvement of venous obstructed symptoms at upper extremity or cephalo-cervical region, were recorded. The filter's shape and location were checked. The possible occurrence of pulmonary embolism was observed. Results: The filter was successfully implanted in supper vena cava in all patients, and the deep venous thrombosis at upper extremity and cephalo-cervical region responded well to the local via-catheter thrombolysis. The filters showed no displacement or tilting. The swelling at upper extremity and cephalo-cervical region was markedly faded away. No symptomatic pulmonary embolism occurred. the filter was successfully retrieved via the femoral vein in four patients. Conclusion: Tulip filter can be safety implanted in superior vena cava and can be smoothly retrieved. The occurrence of pulmonary embolism can be effectively prevented if corresponding local via-catheter thrombolysis is carried out. (authors)

  12. [Bilateral deep venous thrombosis and vena cava aplasia treated with local thrombolysis

    DEFF Research Database (Denmark)

    Pelta, A.M.; Jørgensen, Maja; Just, Sven Richardt Lundgren

    2008-01-01

    In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete...

  13. Haematogenous tumour growth in the inferior vena cava in a patient with a nonseminomatous testicular tumour

    NARCIS (Netherlands)

    Ham, S J; Koops, H Schraffordt; Sleijfer, D T; Freling, N M; Molenaar, W M

    1991-01-01

    The case history is reported of a patient with an invasion of the inferior vena cava by metastases of a non-seminomatous testicular tumour. He was treated with combination chemotherapy, followed by laparotomy and resection of residual tumour tissue. Fourteen months after this operation he is in good

  14. Septic thrombosis of the inferior vena cava treated with percutaneous mechanical thrombectomy

    NARCIS (Netherlands)

    Burgmans, Mark C.; Rommes, Johannes H.; Spronk, Peter E.; van Nidek, Robert J. P. Brouerius; Bouma, Wim H.; Gratama, Jan Willem C.

    2006-01-01

    The present report describes a patient with septic thrombosis of the inferior vena cava (IVC) related to a subhepatic abscess adjacent to the IVC. Despite prolonged antimicrobial therapy and systemic anticoagulation, sepsis and septic embolism persisted while the size of the thrombus increased.

  15. Continuous and Lp estimates for the complex Monge-Ampère equation on bounded domains in ℂn

    Directory of Open Access Journals (Sweden)

    Patrick W. Darko

    2002-01-01

    Full Text Available Continuous solutions with continuous data and Lp solutions with Lp data are obtained for the complex Monge-Ampère equation on bounded domains, without requiring any smoothness of the domains.

  16. 78 FR 28273 - Alpine Investors IV SBIC, LP; Notice Seeking Exemption Under Section 312 of the Small Business...

    Science.gov (United States)

    2013-05-14

    ... SMALL BUSINESS ADMINISTRATION [License No. 09/09-0461] Alpine Investors IV SBIC, LP; Notice... hereby given that Alpine Investors IV SBIC, LP, 3 Embarcadero Center, Suite 2330, San Francisco, CA, a...'') Rules and [[Page 28274

  17. The initial experience of transjugular retrieval of Geunther Tulip inferior vena cava filters

    International Nuclear Information System (INIS)

    Xiao Liang; Shen Jing; Tong Jiajie; Li Haiwei; Xu Ke

    2011-01-01

    Objective: To explore the indications and technical procedures of transjugular retrieval of Geunther Tulip inferior vena cava filters. Methods: Seventy-four patients (40 males and 34 females with a mean age of 45.8 years) with acute lower extremity deep venous thrombosis encountered in our hospital from September 2007 to Mar 2009 were involved in this study. The onset of the disease was from one day to 14 days. Clinical symptoms included swelling, pain, cyanosis or pallescence of the affected limb with higher or normal skin temperature. Thirty-one patients who complicated with pulmonary embolism suffered from dyspnoea, chest pain, hemoptysis, etc. Implantation of Geunther Tulip retrievable inferior vena cava filters through femoral or right internal jugular vein was carried out, which was followed by intravenous transcatheter thrombolysis. Vascular ultrasound and angiography showed no fresh or free thrombus in 12-80 days after initial treatment, then the Geunther Tulip filter was taken out from right internal jugular vein, and inferior vena cavography was performed again. All patients accepted anticoagulation and antibiotic treatment for 3-5 days after operation. A follow-up lasting for 4-12 months was made. Results: Successful implantation of Geunther Tulip retrievable inferior vena cava filter with only one session was obtained in all 74 patients. During implantation procedure one filter became tilted 25 degrees. Successful removal of Geunther Tulip retrievable inferior vena cava filter was achieved in 40 patients in 41.3 days (12-80 days) after the filter was delivered, and the procedure cost only 5.8 minutes (1-115 minutes) with a successful rate of 97.6% (40/41). Failure of retrieval of IVC filter due to compact adhesion of the filter to IVC wall happened in one patient. Inferior vena cavography again confirmed that there was no any sign of vascular perforation or rupture. Retrieval of IVC filter was not performed in other 33 patients and no clinical

  18. Virginia Tech dining keeps customer service fresh (with Relish!)

    OpenAIRE

    Chadwick, Heather Riley

    2005-01-01

    Virginia Tech is consistently ranked among the top universities in providing its students with the very best in dining options. One important way they make that happen is keeping in touch with student preferences and needs.

  19. Virginia Tech's Cook Counseling Center receives international counseling accreditation

    OpenAIRE

    DeLauder, Rachel

    2010-01-01

    The Virginia Tech Thomas E. Cook Counseling Center has been accredited by the International Association of Counseling Services, Inc., an organization of United States, Canadian, and Australian counseling agencies based in Alexandria, Va.

  20. What Is the Tech Prep/Associate Degree Program?

    Science.gov (United States)

    Parnell, Dale

    1993-01-01

    Discusses the nature, importance, and future of the Tech Prep/Associate Degree program. Suggests that these programs must move beyond simple articulation and become aggressive in jointly examining, developing, and sustaining high quality educational programs. (JOW)

  1. Former Virginia Tech Aerospace and Ocean Engineering Department Head Dies

    OpenAIRE

    Gilbert, Karen

    2003-01-01

    James B. Eades, Jr., retired aerospace research scientist from Bluefield, W. Wa., and former professor and department head of aerospace and ocean engineering at Virginia Tech, died Dec. 14 at Veteran's Hospital in Washington, D.C. He was 80.

  2. Does Service Innovation Matter in High-Tech Industry?

    OpenAIRE

    Wang, Chao-Hung

    2014-01-01

    Service innovation has been found to be a major driver of innovation performance in service contexts. But this issue raises questions concerning the extent to which the relationship between market orientation and innovation performance holds in the high-tech industry. Relatively little research has examined how market orientation contributes to innovation performance through service innovation. We here report an empirical study of 235 Taiwanese high-tech firms to examine the influence of mark...

  3. Pricing Policy and Strategies for Consumer High-Tech Products

    Directory of Open Access Journals (Sweden)

    Dovleac, L.

    2014-06-01

    Full Text Available This paper highlights the complex process of price setting for consumer high-tech products. These prices are highly influenced by some external factors from the economic and social environment. The main objective of this paper is to establish the most effective pricing policies and strategies used by high-tech companies of various sizes. Decisions about price fixing for consumer high-technology products are largely influenced by consumer behaviour, too.

  4. Heart block and cardiac embolization of fractured inferior vena cava filter.

    Science.gov (United States)

    Abudayyeh, Islam; Takruri, Yessar; Weiner, Justin B

    2016-01-01

    A 66-year-old man underwent a placement of an inferior vena cava filter before a gastric surgery 9 years prior, presented to the emergency room with a complete atrioventricular block. Chest x-ray and transthoracic echocardiogram showed struts migrating to right ventricle with tricuspid regurgitation. Cardiothoracic surgery was consulted and declined an open surgical intervention due to the location of the embolized fragments and the patient's overall condition. It was also felt that the fragments had migrated chronically and were adhered to the cardiac structures. The patient underwent a dual-chamber permanent pacemaker implantation. Post-implant fluoroscopy showed no displacement of the inferior vena cava filter struts due to the pacemaker leads indicating that the filter fracture had likely been a chronic process. This case highlights a rare combination of complications related to inferior vena cava filter fractures and the importance of assessing for such fractures in chronic placements. Inferior vena cava filter placement for a duration greater than 1 month can be associated with filter fractures and strut migration which may lead to, although rare, serious or fatal complications such as complete atrioventricular conduction system disruption and valvular damage including significant tricuspid regurgitation. Assessing for inferior vena cava filter fractures in chronic filter placement is important to avoid such complications. When possible, retrieval of the filter should be considered in all patients outside the acute setting in order to avoid filter-related complications. Filter retrieval rates remain low even when a retrievable filter is in place and the patient no longer has a contraindication to anticoagulation.

  5. TrapEase inferior vena cava filter placement: use of the subclavian vein.

    Science.gov (United States)

    Stone, Patrick A; Aburahma, Ali F; Hass, Stephen M; Hofeldt, Matthew J; Zimmerman, William B; Deel, John T; Deluca, John A

    2004-01-01

    The purpose of this paper was to evaluate the safety and technical success of TrapEase inferior vena cava filter placement via the subclavian vein. As of yet, no reports in the literature have specifically investigated the use of the subclavian vein as a route for deploying TrapEase vena cava filters. Retrospective chart review was conducted of 135 patients with attempted TrapEase inferior vena cava filter placement over a 2-year period. In a majority of cases, the choice of subclavian vein approach was based primarily on surgeon preference. Other circumstances for subclavian vein deployment included cervical immobilization secondary to trauma, desire for concomitant placement of a subclavian long-term central venous access catheter, and patient body habitus limiting exposure to the internal jugular vein. One hundred and thirty-five filters were placed over this 2-year period. The internal jugular vein approach was used in 56 patients, the femoral vein approach in 39 patients, and the subclavian vein approach in 40 patients. Thirty-nine of the 40 TrapEase filter placements using the subclavian vein were successful. Twenty-six were deployed through the right subclavian vein and 14 through the left subclavian vein. The single failed subclavian deployment was due to the inability to pass the guidewire adequately into the inferior vena cava after successful cannulation of the right subclavian vein. The average deployment time for subclavian vein placement was 26 minutes when TrapEase filter placement was the only procedure performed. No insertional complications were encountered, specifically no pneumothoraces confirmed by chest radiography or fluoroscopy. The subclavian vein provides an alternative site of access for the TrapEase inferior vena cava filter. This route is comparable to other alternative methods evaluated both in average deployment time and complication occurrence. Furthermore, the subclavian vein route is valuable in patients with limited central access

  6. Design Optimization of Vena Cava Filters: An application to dual filtration devices

    Energy Technology Data Exchange (ETDEWEB)

    Singer, M A; Wang, S L; Diachin, D P

    2009-12-03

    Pulmonary embolism (PE) is a significant medical problem that results in over 300,000 fatalities per year. A common preventative treatment for PE is the insertion of a metallic filter into the inferior vena cava that traps thrombi before they reach the lungs. The goal of this work is to use methods of mathematical modeling and design optimization to determine the configuration of trapped thrombi that minimizes the hemodynamic disruption. The resulting configuration has implications for constructing an optimally designed vena cava filter. Computational fluid dynamics is coupled with a nonlinear optimization algorithm to determine the optimal configuration of trapped model thrombus in the inferior vena cava. The location and shape of the thrombus are parameterized, and an objective function, based on wall shear stresses, determines the worthiness of a given configuration. The methods are fully automated and demonstrate the capabilities of a design optimization framework that is broadly applicable. Changes to thrombus location and shape alter the velocity contours and wall shear stress profiles significantly. For vena cava filters that trap two thrombi simultaneously, the undesirable flow dynamics past one thrombus can be mitigated by leveraging the flow past the other thrombus. Streamlining the shape of thrombus trapped along the cava wall reduces the disruption to the flow, but increases the area exposed to abnormal wall shear stress. Computer-based design optimization is a useful tool for developing vena cava filters. Characterizing and parameterizing the design requirements and constraints is essential for constructing devices that address clinical complications. In addition, formulating a well-defined objective function that quantifies clinical risks and benefits is needed for designing devices that are clinically viable.

  7. 75 FR 8921 - Grant of Authority for Subzone Status; Brightpoint North America L.P. (Cell Phone Kitting and...

    Science.gov (United States)

    2010-02-26

    ... Status; Brightpoint North America L.P. (Cell Phone Kitting and Distribution) Indianapolis, IN Pursuant to... the cell phone kitting and distribution facilities of Brightpoint North America L.P., located in... cell phones at the facilities of Brightpoint North America L.P., located in Plainfield, Indiana...

  8. 75 FR 14644 - Gemini Investors IV, L.P., Notice Seeking Exemption Under Section 312 of the Small Business...

    Science.gov (United States)

    2010-03-26

    ... SMALL BUSINESS ADMINISTRATION [License No. 01/01-0410] Gemini Investors IV, L.P., Notice Seeking... given that Gemini Investors IV, L.P., 20 William Street, Wellesley, MA 02481, a Federal Licensee under... Regulations (13 CFR 107.730). Gemini Investors IV, L.P. proposes to provide equity and debt financing to...

  9. Significance of Lipiodol-CT in the evaluation of therapeutic effects of Lp-TAE for hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Jinno, Kenji; Tokuyama, Katuyuki; Yumoto, Yasuhiro

    1988-01-01

    In 20 lesions of 17 patients treated with arterial infusion of SMANCS dissolved in lipiodol (Lp) and transcatheter arterial embolization (TAE) for hepatocellular carcinoma (HCC), Lp deposition within the tumor were depicted on CT (Lp-CT). The findings of Lp-CT were compared with those of macroscopic, soft X-ray, and histologic examinations for resected specimens. Lp-CT appearance of HCC fell into four types: (I) complete type - round and homogeneous high density area (HDA) - in which Lp was deposited over the whole area; (II) defective type - inhomogeneous HDA - in which Lp was deposited in part of the tumor; (III) aggregated type - aggregation of small HDA; (IV) deficient type - no HDA - in which little or no Lp was deposited. Type I was found in 20 % of the lesions, type II in 25 %, type III in 20 %, and type IV in 35 %. In type I, HCC was of macroscopically nodular form with expansive growth and pseudocapsule and of histologically trabecular form with broad blood spaces and inviable cancer cells. In the other types, similar findings were seen in the necrotic area in which Lp was deposited, whereas scirrhous or compact type of HCC was histologically seen in the area containing viable cancer cells in which no Lp was deposited. The presence or not of Lp deposition, as depicted on CT, was closely correlated with histologic findings, which has significant implications for the evaluation of therapeutic efficacy of TAE with Lp. (Namekawa, K.)

  10. The lysine-peptoid hybrid LP5 maintain activity under physiological conditions and affects virulence gene expression in Staphylococcus aureus

    DEFF Research Database (Denmark)

    Gottschalk, Sanne; Ingmer, Hanne; Thomsen, Line E.

    2016-01-01

    The antimicrobial peptide, LP5, is a lysine-peptoid hybrid, with antimicrobial activity against clinically relevant bacteria. Here, we investigated how various environmental conditions affect the antimicrobial activity of LP5 against Staphylococcus aureus (S. aureus). We found that LP5 maintained...

  11. 75 FR 51451 - Erie Boulevard Hydropower, L.P.; Notice of Intent To File License Application, Filing of Pre...

    Science.gov (United States)

    2010-08-20

    ... Hydropower, L.P.; Notice of Intent To File License Application, Filing of Pre-Application Document, and.... Project No.: 7320-040. c. Dated Filed: June 29, 2010. d. Submitted By: Erie Boulevard Hydropower, L.P. e...: John Mudre at (202) 502-8902; or e-mail at [email protected] . j. Erie Boulevard Hydropower, L.P...

  12. Retrievable Inferior vena cava filters in pregnancy: Risk versus benefit?

    Science.gov (United States)

    Crosby, David A; Ryan, Kevin; McEniff, Niall; Dicker, Patrick; Regan, Carmen; Lynch, Caoimhe; Byrne, Bridgette

    2018-03-01

    Venous thromboembolism remains one of the leading causes of maternal mortality in the developed world. Retrievable inferior vena cava (IVC) filters have a role in the prevention of lethal pulmonary emboli when anticoagulation is contraindicated or has failed [1]. It is unclear whether or not the physiological changes in pregnancy influence efficacy and complications of these devices. The decision to place an IVC filter in pregnancy is complex and there is limited information in terms of benefit and risk to the mother. The objective of this study was to determine the efficacy and safety of these devices in pregnancy and to compare these with rates reported in the general population. The aim of this study was report three recent cases of retrievable IVC filter use in pregnant women in our department and to perform a systematic review of the literature to identify published cases of filters in pregnancy. The efficacy and complication rates of these devices in pregnancy were estimated and compared to rates reported in the general population in a recent review [2]. Fisher's exact test was used for statistical analysis. In addition to our three cases, 16 publications were identified with retrievable IVC filter use in 40 pregnant women resulting in a total of 43 cases. There was no pulmonary embolus in the pregnant group (0/43) compared to 57/6291 (0.9%) in the general population. Thrombosis of the filter (2.3% vs. 0.9%, p = 0.33) and perforation of the IVC (7.0% vs 4.4%, p = 0.44) were more common in pregnancy compared to the general population but the difference was not statistically significant. Failure to retrieve the filter is more likely to occur in pregnancy (26% vs. 11%, p = 0.006) but this did not correlate with the type of device (p = 0.61), duration of insertion (p = 0.58) or mode of delivery (p = 0.37). Data for retrievable IVC filters in pregnancy is limited and there may be a publication bias towards complicated cases. This study

  13. Iterest grows for Dutch mid-tech and low-tech greenhouse technology : A greenhouse to suit all tropical conditions (interview with Anne Elings)

    NARCIS (Netherlands)

    Kierkels, T.; Elings, A.

    2014-01-01

    The Netherlands sets the standard for high-tech greenhouses worldwide. But increasingly suppliers are looking too at possibilities within the mid-tech and even the low-tech market segments. The Dutch government is supporting demonstration projects, for example in Mexico, East Africa and Malaysia.

  14. FinTech Market Development Perspectives

    Directory of Open Access Journals (Sweden)

    Kalmykova Ekaterina

    2016-01-01

    Full Text Available Fast development of technologies has led to emergence of the new market – FinTech – which is very attractive for investors today. By now this market has a great number of different concepts: P2P-crediting, E-wallets, Bitcoins, mPOS-acquiring, T-commerce, mobile banks, etc. Many of these tools have already heavily entered our ordinary life. People can obtain any credits through special services on the Internet from other users without participation of banks, pay by credit card using mobile devices, and get information about expenses and incomes according to the card anywhere in the world. Users do not need to go to banks anymore and to spend their time for credit arrangements, currency exchange, to look for ATMs to remove cash. Purchases on the Internet can be paid not only in rubles, but also in new digital currency. These tools make life easier, however, they pose a serious threat for banks. Now, bank institutions should create more convenient and utility services for the clients to keep clients. Therefore, bank and credit systems start to change actively.

  15. Complications after the placement of domestic ZQL filter and imported inferior vena caval filter: a mid-and long-term comparative study

    International Nuclear Information System (INIS)

    Huang Kun; Zhao Yi; Xu Ke; Feng Bo; Liang Songnian

    2009-01-01

    Objective: To investigate the clinical value of domestic ZQL-type inferior vena caval filter through comparing its complications with that of imported inferior vena caval filter. Methods: Domestic ZQL-type inferior vena caval filter was placed in 62 patients (study group) and imported inferior vena caval filter in 58 patients (control group) for the treatment of deep venous thrombosis of the lower limb. Abdominal plain film, lower limb phlebography and/or pulmonary arteriography, color Doppler ultrasonography were performed after the procedure. 3D-CT scanning was carried out when pulmonary embolism was suspected. The complications were documented and analyzed. Results In all patients the inferior vena caval filter was successfully implanted in planned site. In study group, the complications included filter migration over 10 cm (n = 1), thrombus in the filter (n = 1), inferior vena cava obstruction (n = 2) and pulmonary embolism (n = 1). In control group, the complications included thrombus in the filter (n = 2), deep venous thrombus of the lower extremities (n = 2), inferior vena cava obstruction (n = 9), venous perforation by filter (n = 1) and pulmonary embolism (n = 1). The data were compared between two groups and statistic analysis showed no significant difference between two groups (P > 0.05). Conclusion: No significant difference in the occurrence of complications exists between domestic ZQL-type inferior vena caval filter and imported inferior vena caval filter, therefore, domestic ZQL-type inferior vena caval filter can safely substitute for the imported filter. (authors)

  16. A New Algorithm for Detecting Cloud Height using OMPS/LP Measurements

    Science.gov (United States)

    Chen, Zhong; DeLand, Matthew; Bhartia, Pawan K.

    2016-01-01

    The Ozone Mapping and Profiler Suite Limb Profiler (OMPS/LP) ozone product requires the determination of cloud height for each event to establish the lower boundary of the profile for the retrieval algorithm. We have created a revised cloud detection algorithm for LP measurements that uses the spectral dependence of the vertical gradient in radiance between two wavelengths in the visible and near-IR spectral regions. This approach provides better discrimination between clouds and aerosols than results obtained using a single wavelength. Observed LP cloud height values show good agreement with coincident Cloud-Aerosol Lidar and Infrared Pathfinder Satellite Observation (CALIPSO) measurements.

  17. Atypical leiomyoma arising in a hepatic vein with extension into the inferior vena cava and right atrium

    International Nuclear Information System (INIS)

    Dunlap, H.J.; Udjus, K.

    1990-01-01

    We report an atypical leiomyoma arising in a hepatic vein and extending into the inferior vena cava and right atrium in a fourteen year old boy. US, CT and MRI facilitated diagnosis and removal of this tumor. (orig.)

  18. Percutaneous transfemoral placement of inferior vena cava filter to prevent pulmonary embolism in patients with malignant tumor

    International Nuclear Information System (INIS)

    Hu Baoshan; Li Yong; Luo Pengfei

    2005-01-01

    Objective: To evaluate the effectiveness and safety of inserting an inferior vena cava filter to prevent the pulmonary embolism (PE) due to detachment of the thrombus in the lower extremities. Methods: Inferior vena cava filter were placed in 37 patients with malignant tumor and deep venous thrombosis from 1998 to 2004. Malignancy was confirmed by pathological or cellular biological examination in all cases. The episode of pulmonary embolism was monitored during a post-intervention follow-up. Results: All the filters were placed in the inferior vena cava safely via a percutaneous femoral venous access. No serious complications such as pulmonary embolism occurred during the follow-up periods. Conclusion: The inferior vena cava filter placement is an effective and safe procedure in preventing the pulmonary embolism in patients with malignant tumor and deep venous thrombosis. (authors)

  19. Thrombosis of the ileo-caval sector: puerperal thrombosis and agenesia thrombosis of the inferior vena cava

    International Nuclear Information System (INIS)

    Garcia Egea, Jorge; Lara Guerrero, Isabel; Fustero Aznar, Jose Miguel; Hermoso Cuenca, Vicente; Velez Lomana, Abel

    2011-01-01

    The thrombosis of the inferior vena cava account for around the 15% of the cases of deep venous thrombosis. This is the case of a puerperal primigravida with a cesarean section labor presenting with a thrombosis initially in the right ovarian vein and then extension to the inferior vena cava. Treatment included low molecular weight heparin in anticoagulant doses; rest with elevation of the extremities and elastic bandage. After a satisfactory process evolution with partial lysis of the thrombus, the oral anticoagulation with Acenocumarol for 6 months was started. The second patient, a man aged 73 with backgrounds of an operated hepatic hydatidosis, had a thrombosis of the infrarenal inferior vena cava and agenesia of retrohepatic segment of the inferior vena cava. The patient remains with anticoagulant treatment including Acenocumarol, elastic bandage and hygienic care. As sequela he had a postphlebitic syndrome and reworsening of the edema leading to its admission in two occasions.(author)

  20. Bilateral Deep Vein Thrombosis Associated with Inferior Vena Cava Agenesis in a Young Patient Manifesting as Low Back Pain

    Directory of Open Access Journals (Sweden)

    Felipe Langer

    2017-04-01

    Full Text Available Congenital absence of the inferior vena cava is a rare vascular anomaly, and most cases are asymptomatic. Nevertheless, patients with inferior vena cava malformations may have increased risk of deep venous thrombosis. Particularly, cases of bilateral deep venous thrombosis may arise owing to an insufficient collateral venous drainage from the lower limbs. We hereby describe a case of a previously healthy young male patient presenting with bilateral lower limb deep venous thrombosis as the initial clinical manifestation of congenital inferior vena cava agenesis. We conclude that in young patients presenting with deep venous thrombosis, especially when thrombosis occurs spontaneously, bilaterally, or recurrently, inferior vena cava anomalies should be thoroughly investigated and ruled out as appropriate.

  1. Fuzzy model investic do High-tech projektů

    Directory of Open Access Journals (Sweden)

    Alžběta Kubíčková

    2013-10-01

    Full Text Available Purpose of the article: Relations among parameters of High-tech projects are very complex, vague, partially inconsistent and multidimensional. Optimal decisions to invest into High-tech companies require top field experts and knowledgeable investors. Therefore the conventional methods of investments analysis are not relevant. Therefore fuzzy logic is introduced. Methodology/methods: A fuzzy knowledge base is a flexible framework for acquisition of vague inconsistent knowledge items which are typical for knowledge economics and consequently for High-tech projects. The pooling of the records and / or observations represents a trade-off between minimal modification of the original data and elimination of inconsistencies among available sets of data. Scientific aim: The paper presents a detailed description of fuzzy model of investment decision making into High-tech firm’s projects. A set of conditional statements was used to formalize the effects of selected variables on investment feasibility of High-tech projects. The main aim is to quantify feasibilities of High-tech projects risk investors make good /not bad decisions. Findings: A set of 50 observations of High-tech companies was transformed into a set of 50 conditional statements using 14 variables. The result is the fuzzy model, which can be used to answer investors’ queries. Two queries are answered and presented in details as an example and as a nucleus of a fuzzy dialogue investor – computer. Conclusions: The main problem is the sparseness of the fuzzy model. Many fuzzy similarities are relatively low and the decision process is therefore often problematic. A much more complex set of variables must be applied to specify the fuzzy model to increase reliability of predictions and decisions.

  2. Removal of a Guenther Tulip retrievable inferior vena cava filter after 147 days in a pediatric patient

    Energy Technology Data Exchange (ETDEWEB)

    Mody, Rekha N.; Stokes, LeAnn S.; Bream, Peter R.; Spottswood, Stephanie E. [Vanderbilt University Medical Center, Department of Radiology, Nashville, TN (United States)

    2006-05-15

    A Guenther Tulip retrievable inferior vena cava filter was placed in a 9-year-old boy with T-cell ALL who had both iliofemoral deep vein thrombosis (DVT) and acute intracranial hemorrhage. The filter was removed 147 days after placement, when the patient was no longer at increased risk for DVT or pulmonary embolus. Removal of the filter did not compromise flow through the vena cava. (orig.)

  3. Removal of a Guenther Tulip retrievable inferior vena cava filter after 147 days in a pediatric patient

    International Nuclear Information System (INIS)

    Mody, Rekha N.; Stokes, LeAnn S.; Bream, Peter R.; Spottswood, Stephanie E.

    2006-01-01

    A Guenther Tulip retrievable inferior vena cava filter was placed in a 9-year-old boy with T-cell ALL who had both iliofemoral deep vein thrombosis (DVT) and acute intracranial hemorrhage. The filter was removed 147 days after placement, when the patient was no longer at increased risk for DVT or pulmonary embolus. Removal of the filter did not compromise flow through the vena cava. (orig.)

  4. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    Energy Technology Data Exchange (ETDEWEB)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello [IRCCS Policlinico San Matteo Foundation, Pavia (Italy)

    2014-06-15

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  5. Dialysis catheter-related superior vena cava syndrome with patent vena cava: Long term efficacy of unilateral viatorr stent-graft avoiding catheter manipulation

    International Nuclear Information System (INIS)

    Quaretti, Pietro; Galli, Franco; Maramarco, Lorenzo Paplo; Corti, Riccardo; Leati, Giovanni; Fiorina, Ilaria; Maestri, Marcello

    2014-01-01

    Central venous catheters are the most frequent causes of benign central vein stenosis. We report the case of a 79-year-old woman on hemodialysis through a twin catheter in the right internal jugular vein, presenting with superior vena cava (SVC) syndrome with patent SVC. The clinically driven endovascular therapy was conducted to treat the venous syndrome with a unilateral left brachiocephalic stent-graft without manipulation of the well-functioning catheter. The follow-up was uneventful until death 94 months later.

  6. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Catherine Yang

    2013-07-01

    Full Text Available Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications.

  7. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    International Nuclear Information System (INIS)

    Yang, Catherine; Trad, Clovis Simao; Trad, Henrique Simao

    2013-01-01

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  8. Congenital inferior vena cava anomalies: a review of findings at multidetector computed tomography and magnetic resonance imaging

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Catherine; Trad, Clovis Simao [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Trad, Henrique Simao, E-mail: hstrad@terra.com.br [Central de Diagnostico Ribeirao Preto (CEDIRP), SP (Brazil); Universidade de Sao Paulo (HC-FMRPUSP), Ribeirao Preto, SP (Brazil). Fac. de Medicina. Hospital das Clinicas; Mendonca, Silvana Machado [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2013-06-15

    Inferior vena cava anomalies are rare, occurring in up to 8.7% of the population, as left renal vein anomalies are considered. The inferior vena cava develops from the sixth to the eighth gestational weeks, originating from three paired embryonic veins, namely the subcardinal, supracardinal and postcardinal veins. This complex ontogenesis of the inferior vena cava, with multiple anastomoses between the pairs of embryonic veins, leads to a number of anatomic variations in the venous return from the abdomen and lower limbs. Some of such variations have significant clinical and surgical implications related to other cardiovascular anomalies and in some cases associated with venous thrombosis of lower limbs, particularly in young adults. The authors reviewed images of ten patients with inferior vena cava anomalies, three of them with deep venous thrombosis. The authors highlight the major findings of inferior vena cava anomalies at multidetector computed tomography and magnetic resonance imaging, correlating them the embryonic development and demonstrating the main alternative pathways for venous drainage. The knowledge on the inferior vena cava anomalies is critical in the assessment of abdominal images to avoid misdiagnosis and to indicate the possibility of associated anomalies, besides clinical and surgical implications. (author)

  9. Vena cava filters and thrombolytic therapeutic monitoring based on functional near-infrared spectroscopy for deep vein thrombosis

    Science.gov (United States)

    Pan, Boan; Liu, Weichao; Fang, Xiang; Zhao, Ke; Li, Ting

    2018-02-01

    Deep vein thrombosis (DVT), happening in inpatients usually and especially with the postoperative population, is a serious disease characterized by an increased incidence. The venography is the golden standard to diagnose DVT. However, it involves invasive contrast agent injection and give patients physical and mental pressure. Functional nearinfrared spectroscopy (fNIRS) has been reported recently to diagnose DVT. Thrombolytic therapy activates the dissolution system with an exogenous activator that dissolves coronary thrombosis. The vena cava filter is a medical filter used for the treatment of thrombosis and the prevention of pulmonary embolism. Here we attempt to use portable NIRS for the DVT monitoring in the whole process of vena cava filter implantation and thrombolytic treatment, and contrast the patients of untreated, vena cava filter implantation and thrombolytic treatment. 19 DVT patients and 12 normal subjects were recruited. Thereinto, 7 patients have taken vena cava filter implantation, and 6 patients have taken the thrombolytic treatment. It was found that deoxyhemoglobins (Δ[Hb]) fluctuates and even increases in DVT. After vena cava filter implantation, Δ[Hb] increases first, then decreases. However, it emerges the rising trend and converge to the curves of normal subjects in thrombolytic treatment. The oxyhemoglobins (Δ[HbO2]) emerges opposite trend in most paradigms. The findings reveal the potential of fNIRS for monitoring DVT and therapeutic effect evaluation of thrombolysis and vena cava filters.

  10. LibraryH3lp: A New Flexible Chat Reference System

    Directory of Open Access Journals (Sweden)

    Pam Sessoms

    2008-09-01

    Full Text Available LibraryH3lp is an integrated IM and web chat system designed specifically for Virtual Reference services in libraries. The software was designed for, and is currently used by, a night-time chat reference collaboraton between several large academic libraries. LibraryH3lp is designed for the workflow of chat reference, supporting multiple simultaneous operators and routing to queues of operators in a particular service area. It also supports web page embeddable chat 'widgets', as well as simultaneous gateways to multiple IM protocols. This article discusses the motivation for the development of the software, and provides an overview of LibraryH3lp's features and technical architecture. Parts of LibraryH3lp are available as open source. The complete application is available as a low-cost hosted service, and will eventually be available to be licensed for local hosting.

  11. LP-tee pikeneb Tartust Pärnuni / Sirje Pärismaa

    Index Scriptorium Estoniae

    Pärismaa, Sirje, 1958-

    2015-01-01

    Norrast pärit tõenduspõhist koostöökultuuri arendava LP-mudeliga (learning environment and pedagogical analysis) on liitumas seitse kooli Pärnust, Viljandist, Puhjast, Tartust ning kolm lasteaeda

  12. Acute superior vena caval syndrome with airway obstruction following elective mediastinoscopy.

    LENUS (Irish Health Repository)

    Power, C K

    2012-02-03

    A 47-year-old female patient had a subclinical superior vena caval syndrome which developed into the \\'full blown\\' acute condition when she was placed into the left lateral position after mediastinoscopy. She developed airway obstruction requiring urgent re-intubation and subsequent admission to the intensive care unit. This subclinical condition might have been suspected pre-operatively if closer attention had been paid to the history, physical examination and review of the computerised axial tomography scan: she had a history of intermittent dysponea, wheeze and cough which was worse on waking and improved as the day progressed, she had a positive Pemberton\\'s sign and the computerised axial tomography scan showed that the lesion was encroaching on the superior vena cava.

  13. Isolated persistent left superior vena cava: A case report and its clinical implications

    Directory of Open Access Journals (Sweden)

    Samarjit Bisoyi

    2017-01-01

    Full Text Available The venous anomaly of a persistent left superior vena cava (PLSVC affects 0.3%-0.5% of the general population. PLSVC with absent right superior vena cava, also termed as "isolated PLSVC," is an extremely rare venous anomaly. Almost half of the patients with isolated PLSVC have cardiac anomalies in the form of atrial septal defect, endocardial cushion defects, or tetralogy of Fallot. Isolated PLSVC is usually innocuous. Its discovery, however, has important clinical implications. It can pose clinical difficulties with central venous access, cardiothoracic surgeries, and pacemaker implantation. When it drains to the left atrium, it may create a right to left shunt. In this case report, we present the incidental finding of isolated PLSVC in a patient who underwent aortic valve replacement. Awareness about this condition and its variations is important to avoid complications.

  14. Roentgenologic diagnosis of pulmonary veins pathologically inflowing into vena cava inferior

    International Nuclear Information System (INIS)

    Shumskij, V.I.; Konstantinova, N.V.; Fedorovich, Yu.N.

    1986-01-01

    The authors considered the problem of X-ray semiotics of the right inferior pulmonary vein pathologically inflowing in the vena cava inferior (4 patients) and the false syndrome of the ''Turkish sabre'' (1 patients). Among the patients there were 2 adults and 3 children. It was noted that the abnormal inflowing of the right lower lobe vein in the vena cava inferior was often combined with different types of heart diseases and defects of the major vessels, mainly with the defect of the interatrial septum, the open arterial canal and hypoplasia of the right pulmonary artery. Radiodiagnosis for this group of patients should incorporate, in addition to routine X-ray methods, angiographic investigation, and its volume in each case should be determined on an individual basis

  15. Creating a Fontan fenestration in a child with dextrocardia and interrupted inferior vena cava

    Directory of Open Access Journals (Sweden)

    Pradeepkumar Charlagorla

    2016-01-01

    Full Text Available Plastic bronchitis is a rare life-threatening complication of the Fontan operation. Transcatheter Fontan fenestration can ameliorate symptoms by decompressing elevated venous pressures. Transcatheter creation of a fenestration can be technically challenging in cases with complex venous anatomy. We report a case of a 5-year-old boy with heterotaxy, dextrocardia with unbalanced atrioventricular canal (AVC, atrial and visceral situs inversus, left-sided superior vena cava (SVC, and left-sided interrupted inferior vena cava (IVC with azygos continuation. With few modifications to the equipment, a successful Fontan fenestration with stent implantation was performed via transjugular approach. At 2-year follow-up, his symptoms of plastic bronchitis improved significantly.

  16. Entrapment of Guide Wire in an Inferior Vena Cava Filter: A Technique for Removal

    International Nuclear Information System (INIS)

    Abdel-Aal, Ahmed Kamel; Saddekni, Souheil; Hamed, Maysoon Farouk; Fitzpatrick, Farley

    2013-01-01

    Entrapment of a central venous catheter (CVC) guide wire in an inferior vena cava (IVC) filter is a rare, but reported complication during CVC placement. With the increasing use of vena cava filters (VCFs), this number will most likely continue to grow. The consequences of this complication can be serious, as continued traction upon the guide wire may result in filter dislodgement and migration, filter fracture, or injury to the IVC. We describe a case in which a J-tipped guide wire introduced through a left subclavian access without fluoroscopic guidance during CVC placement was entrapped at the apex of an IVC filter. We describe a technique that we used successfully in removing the entrapped wire through the left subclavian access site. We also present simple useful recommendations to prevent this complication.

  17. Breast varices: imaging findings of an unusual presentation of collateral pathways in superior vena caval syndrome

    International Nuclear Information System (INIS)

    Oezdemir, Ayseguel; Ilgit, Erhan T.; Konus, Oeznur L.; Cetin, Meltem; Oezsunar, Yelda

    2000-01-01

    Imaging findings are presented of an unusual pathway of collateral circulation consisting of bilateral and diffuse dilated breast veins from a patient with long standing superior vena caval syndrome. The main importance of this case is the extent of the collateral development through the breast veins, serving as the major pathway of collateral circulation. Identification of this unusual collateral development, which resembles breast varices, was performed with contrast-enhanced chest CT scans, digital subtraction venography, color Doppler ultrasonography, and mammographic studies. Collateral development was secondary to a long segment idiopathic venous occlusion involving bilateral subclavian and brachiocephalic veins as well as vena cava superior. We conclude that dilated breast veins when detected on any imaging modality should raise the suspicion of central venous obstruction

  18. Radiation-induced leiomyosarcoma of the great vessels presenting as superior vena cava syndrome

    International Nuclear Information System (INIS)

    Weiss, K.S.; Zidar, B.L.; Wang, S.

    1987-01-01

    A patient with a pleomorphic intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presented clinically with a superior vena cava syndrome. A latent period of 29 years elapsed between receiving orthovoltage radiation to the neck and right side of chest to treat recurrent ganglioneuroblastoma, and the appearance of a leiomyosarcoma and subsequent recurrences. The patient underwent partial resection of the tumor, received adjunct chemotherapy, and was shown to be free of disease by clinical tests and by magnetic resonance imaging (MRI) 17 months after completion of chemotherapy. The criteria for the diagnosis of radiation-induced sarcomas are reviewed in relation to the present case. The critical role of magnetic resonance imaging in both the diagnosis and continued follow-up of the patient is described. This would appear to be the first reported case of radiation-induced intravascular leiomyosarcoma of the great vessels of the neck and mediastinum presenting as a superior vena cava syndrome

  19. Bilateral dyb venos trombose og vena cava-aplasi behandlet med lokal trombolyse

    DEFF Research Database (Denmark)

    Pelta, A.M.; Jorgensen, M.; Jensen, L.P.

    2008-01-01

    In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete thr...... thrombus resolution and no valvular incompetence at three months follow-up. In our opinion this treatment should be offered even in complex cases of acute proximal deep venous thrombosis Udgivelsesdato: 2008/5/19......In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete...

  20. [Bilateral deep venous thrombosis and vena cava aplasia treated with local thrombolysis

    DEFF Research Database (Denmark)

    Pelta, A.M.; Jørgensen, Maja; Just, Sven Richardt Lundgren

    2008-01-01

    In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete thr...... thrombus resolution and no valvular incompetence at three months follow-up. In our opinion this treatment should be offered even in complex cases of acute proximal deep venous thrombosis Udgivelsesdato: 2008/5/19......In this case report the treatment of a young man with bilateral iliaco-femoral DVT and vena cava aplasia is presented. The patient was treated with catheter-directed thrombolysis; the catheters were introduced in the thrombus of both legs via v. popliteae. The treatment led to almost complete...

  1. Percutaneous retrieval of a vena cava filter from the right atrium: case report

    Energy Technology Data Exchange (ETDEWEB)

    Rasuli, P. [The Ottawa Hospital and University of Ottawa, Dept. of Radiology, Ottawa, Ontario (Canada); Mehran, R. [The Ottawa Hospital and University of Ottawa, Dept. of Thoracic Surgery, Ottawa, Ontario (Canada); French, G. [The Ottawa Hospital and University of Ottawa, Dept. of Radiology, Ottawa, Ontario (Canada); Turek, M. [The Ottawa Hospital and University of Ottawa, Dept. of Internal Medicine, Ottawa, Ontario (Canada); Lalonde, K.A. [The Ottawa Hospital and University of Ottawa, Dept. of Thoracic Surgery, Ottawa, Ontario (Canada); Cardinal, P. [The Ottawa Hospital and University of Ottawa, Dept. of Internal Medicine, Ottawa, Ontario (Canada)

    2000-07-01

    Migration of vena cava filters can occur spontaneously, but it can also occur as a result of entanglement of the filter with a guidewire, particularly during 'blind' (unguided) insertion of a central venous line. When a filter migrates to the heart, traditional practice has been either to leave the filter in place or to remove it surgically by means of open heart surgery and cardiopulmonary bypass. We found only 6 reports of successful percutaneous retrieval or repositioning of a vena cava filter (Table 1). We describe a new interventional technique for retrieving a filter from the right atrium and a novel endosurgical method for removing a filter from the innominate vein. (author)

  2. Convex Hypersurfaces and $L^p$ Estimates for Schr\\"odinger Equations

    OpenAIRE

    Zheng, Quan; Yao, Xiaohua; Fan, Da

    2004-01-01

    This paper is concerned with Schr\\"odinger equations whose principal operators are homogeneous elliptic. When the corresponding level hypersurface is convex, we show the $L^p$-$L^q$ estimate of solution operator in free case. This estimate, combining with the results of fractionally integrated groups, allows us to further obtain the $L^p$ estimate of solutions for the initial data belonging to a dense subset of $L^p$ in the case of integrable potentials.

  3. State of the Art in LP-WAN Solutions for Industrial IoT Services

    OpenAIRE

    Sanchez-Iborra, Ramon; Cano, Maria-Dolores

    2016-01-01

    The emergence of low-cost connected devices is enabling a new wave of sensorization services. These services can be highly leveraged in industrial applications. However, the technologies employed so far for managing this kind of system do not fully cover the strict requirements of industrial networks, especially those regarding energy efficiency. In this article a novel paradigm, called Low-Power Wide Area Networking (LP-WAN), is explored. By means of a cellular-type architecture, LP-WAN–base...

  4. Increase in Multicast OFDM Data Rate in PLC Network using Adaptive LP-OFDM

    OpenAIRE

    Maiga , Ali; Baudais , Jean-Yves; Hélard , Jean-François

    2009-01-01

    ISBN: 978-1-4244-3523-4; International audience; Linear precoding (LP) technique applied to OFDM systems has already proved its ability to significantly increase the system throughput in a powerline communication (PLC) context. In this paper, we propose resource allocation algorithms based on the LP technique to increase the multicast OFDM systems bit rate. The conventional multicast capacity is limited by the user which experiences the worst channel conditions. To increase the multicast bit ...

  5. Lr-Lp Stability of the Incompressible Flows with Nonzero Far-Field Velocity

    Directory of Open Access Journals (Sweden)

    Jaiok Roh

    2011-01-01

    Full Text Available We consider the stability of stationary solutions w for the exterior Navier-Stokes flows with a nonzero constant velocity u∞ at infinity. For u∞=0 with nonzero stationary solution w, Chen (1993, Kozono and Ogawa (1994, and Borchers and Miyakawa (1995 have studied the temporal stability in Lp spaces for 11 and obtain Lr-Lp stability as Kozono and Ogawa and Borchers and Miyakawa obtained for u∞=0.

  6. TRAC-PF1 code assessment using OECD LOFT LP-FP-1 experiment

    International Nuclear Information System (INIS)

    Barbero, F.J.

    1992-04-01

    This report assesses thermal-hydraulic aspects of LOFT LP-FP-1 experiment making use of TRAC-PF1/MOD1. LP-FP-1 experiment studies the system thermal-hydraulic and core thermal response for initial and boundary conditions similar to a large-break design basis LOCA leading to fission product release from the fuel cladding gap region. It also assesses the fission product retention effectiveness of the PWR-ECCS in best estimate conditions

  7. Reversal of flow in the inferior vena cava and hepatic veins on dynamic CT

    International Nuclear Information System (INIS)

    Lelij, H. van der; Mallens, W.M.C.

    1988-01-01

    A tricuspid insufficiency may not be clinically evident and may remain unknown to the clinician. The phenomenon of a reversal of inferior vena caval blood flow and hepatic veins is known to occur in tricuspid regurgitation from right ventricular angiography and duplex scanning. Demonstration of such a reversal flow on a dynamic CT scan, as in our case, has, to our knowledge, not as yet been reported

  8. Importance of a persisting left vena cava superior in pacemaker therapy

    International Nuclear Information System (INIS)

    Marosi, G.; Sagi, J.; Pokorny, L.; Simon, Z.; Orvostudomangi Egyetem, Szeged

    1982-01-01

    Basing on the description of a specific case and a review of literature, the article discusses the relationship between persisting left vena cava superior and pacemaker therapy. The article covers the technical problems caused by the vascular anomaly, the complications which can be expected, the possibilities in respect of recognising the vascular anomaly, as well as the methods for coping with the special situation prevailing in a particular case. (orig.) [de

  9. The diagnostic importance of the recognition of the inferior Vena cava abnormalities on CT-examinations

    International Nuclear Information System (INIS)

    Gouliamos, A.; Striggaris, K.; Haliasos, N.; Vlahos, N.; Pontifex, G.

    1981-01-01

    Two unusual variations of the Vena cava inferior, as shown by CT examinations, are reported and characteristic X-rays, as well as CT scans, are presented. The first case shows an IVC course to the left of the aorta and the second case absence of the intrahepatic portion of the IVC with azygos continuation. Difficulties in the differential diagnosis are analyzed and discussed, both demonstrated by plain X-rays and CT scans. (orig.) [de

  10. Diagnostic importance of the recognition of the inferior Vena cava abnormalities on CT-examinations

    Energy Technology Data Exchange (ETDEWEB)

    Gouliamos, A.; Striggaris, K.; Haliasos, N.; Vlahos, N.; Pontifex, G.

    1981-09-01

    Two unusual variations of the Vena cava inferior, as shown by CT examinations, are reported and characteristic X-rays, as well as CT scans, are presented. The first case shows an IVC course to the left of the aorta and the second case absence of the intrahepatic portion of the IVC with azygos continuation. Difficulties in the differential diagnosis are analyzed and discussed, both demonstrated by plain X-rays and CT scans.

  11. Inferior Vena Cava and Renal Vein Thrombosis Associated with Thymic Carcinoma

    Directory of Open Access Journals (Sweden)

    Vlad Teodor Berbecar

    2017-01-01

    Full Text Available Thymic tumors are rare mediastinal tumors that can present with a wide variety of symptoms. They can cause distant manifestations and are frequently associated with paraneoplastic syndromes. In our case, we describe the evolution of a 68-year-old male whose first manifestation was thrombosis of the inferior vena cava and renal veins. Thrombosis of large abdominal veins is rare, especially without being associated with any other comorbidity or risk factors.

  12. Superior Vena Cava Syndrome in a Patient with Small-Cell Lung Cancer: A Case Report

    OpenAIRE

    Christina Brzezniak; Bryan Oronsky; Corey A. Carter; Bennett Thilagar; Scott Caroen; Karen Zeman

    2017-01-01

    Superior vena cava (SVC) syndrome, a potential oncologic emergency, is closely associated with malignancy and right-sided lung cancer in particular. A case of SVC syndrome presenting with facial swelling, neck distension, and enlarged veins of the upper chest, which developed over a period of 5 weeks in a 46-year-old patient on a clinical trial with small-cell lung cancer, is reported. Computed tomography scan of the chest revealed slight enlargement of a superior conglomerate mediastinal lym...

  13. La arteria radial puede ser una alternativa a la vena safena

    Directory of Open Access Journals (Sweden)

    Oscar Gil-Albarova

    2011-10-01

    Full Text Available La arteria radial se ha propuesto como alternativa a la vena safena en cirugía de revascularización miocárdica con el objetivo de mejorar la permeabilidad a largo plazo de los injertos. Se analizan los datos provenientes de los estudios prospectivos aleatorizados y los de trabajos retrospectivos con gran número de pacientes y seguimiento a largo plazo.

  14. Monorail system for percutaneous repositioning of the Greenfield vena caval filter.

    Science.gov (United States)

    Guthaner, D F; Wyatt, J O; Mehigan, J T; Wright, A M; Breen, J F; Wexler, L

    1990-09-01

    The authors describe a technique for removing or repositioning a malpositioned Greenfield inferior vena caval filter. A "monorail" system was used, in which a wire was passed from the femoral vein through the apical hole in the filter and out the internal jugular vein; the wire was held taut from above and below and thus facilitated repositioning or removal of the filter. The technique was used successfully in two cases.

  15. Outcome of prolonged acute vena cava occlusion after iatrogenic transection and repair in a dog

    OpenAIRE

    Halwagi, Marie-Chantal; Crawford, Evan; Hoddinott, Katie; Oblak, Michelle L.

    2017-01-01

    A 12-year-old castrated male Airedale terrier dog was diagnosed with a hepatocellular carcinoma in the right medial liver lobe. During tumor resection, inadvertent stapling and transection of the caudal vena cava occurred. Complete caval occlusion was required for 18 minutes and primary anastomosis was completed. The dog received 2 blood transfusions and developed mild pelvic limb edema after surgery. Computed tomography evaluation 9 months after surgery showed collateral circulation and susp...

  16. Anomalous inferior vena cava in association with omphalocele: a case report

    Energy Technology Data Exchange (ETDEWEB)

    Antoniou, E E.H. [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Matsuoka, S [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Mori, K [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Hayabuchi, Y [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan); Kuroda, Y [Dept. of Pediatrics, School of Medicine, Univ. of Tokushima (Japan)

    1995-06-01

    We present the case of a 6-year-old boy who had an omphalocele repaired at day 1 of life. He had a secundum atrial septal defect and an anomalous inferior vena cava of a type which has not been previously reported. Cine-MRI was a useful noninvasive tool for diagnosing the anomalous subaortic innominate vein and four immature vessels which make up the venous drainage systems of the lumbar region. (orig.)

  17. Anomalous inferior vena cava in association with omphalocele: a case report

    International Nuclear Information System (INIS)

    Antoniou, E.E.H.; Matsuoka, S.; Mori, K.; Hayabuchi, Y.; Kuroda, Y.

    1995-01-01

    We present the case of a 6-year-old boy who had an omphalocele repaired at day 1 of life. He had a secundum atrial septal defect and an anomalous inferior vena cava of a type which has not been previously reported. Cine-MRI was a useful noninvasive tool for diagnosing the anomalous subaortic innominate vein and four immature vessels which make up the venous drainage systems of the lumbar region. (orig.)

  18. Treatment of pacemaker-induced superior vena cava syndrome by balloon angioplasty and stenting.

    LENUS (Irish Health Repository)

    Klop, B

    2011-01-01

    Superior vena cava (SVC) syndrome is a rare but serious complication after pacemaker implantation. This report describes three cases of SVC syndrome treated with venoplasty and venous stenting, with an average follow-up of 30.7 (±3.1) months. These cases illustrate that the definitive diagnosis, and the extent and location of venous obstruction, can only be determined by venography.

  19. Gallium SPECT detection of neoplastic intravascular obstruction of the superior vena cava

    International Nuclear Information System (INIS)

    Swayne, L.C.; Kaplan, I.L.

    1989-01-01

    A rare case of an intravascular neoplastic obstruction of the superior vena cava is discussed. The lesion was detected with gallium single photon emission computed tomography (SPECT) despite a normal appearance on a concurrent radiographic CT study. A computer-generated composite SPECT-CT image confirmed the intravascular localization of the radioisotope, and a subsequent CT-guided transthoracic needle biopsy revealed a poorly differentiated adenocarcinoma

  20. Bilateral adrenal cystic neuroblastoma with superior vena cava syndrome and massive intracystic haemorrhage

    International Nuclear Information System (INIS)

    Pinarli, Faruk Guclu; Danaci, Murat; Diren, Baris; Tander, Burak; Rizalar, Riza; Dagdemir, Ayhan; Acar, Sabri

    2004-01-01

    Bilateral cystic adrenal tumours are a rare presentation of neuroblastoma. Intratumoural haemorrhage is a frequent finding in neuroblastoma, but is rarely symptomatic. We present an 11-month-old girl with predominantly cystic bilateral neuroblastomas and distant lymph-node metastasis. Massive intracystic haemorrhage and superior vena cava (SVC) syndrome were ominous prognostic factors, leading to death. Large tumours with intracystic haemorrhage might require a conservative approach. (orig.)

  1. Technical Error During Deployment Leads to Vena Cava Filter Migration and Massive Pulmonary Embolism

    International Nuclear Information System (INIS)

    Fotiadis, Nikolas I.; Sabharwal, Tarun; Dourado, Renato; Fikrat, Shabbo; Adam, Andreas

    2008-01-01

    The Guenther Tulip vena cava filter is a safe, effective, well-established device for pulmonary embolism prophylaxis. We report a patient in whom there was migration of the filter to the right atrium, 2 weeks after insertion, caused by a technical error during deployment. An attempt to retrieve the filter percutaneously failed, necessitating removal at open-heart surgery. The potential causes of migration are described and the lessons learned from this unusual case are outlined.

  2. Serial repositioning of a Guenther tulip retrievable inferior vena cava filter in a pediatric patient

    International Nuclear Information System (INIS)

    Haider, Ehsan A.; Rosen, J. Choi; Torres, Carlos; Valenti, David A.

    2005-01-01

    We report an 11-year-old boy who required inferior vena cava (IVC) filtration for a prolonged period of time. A retrievable IVC filter was placed and repositioned three times, providing a total of 60 days of IVC filtration. The filter was removed when his risk of pulmonary embolus had decreased substantially. This is a relatively uncommon practice in the pediatric population. The technique is presented, and the available literature is reviewed. (orig.)

  3. LpMab-23: A Cancer-Specific Monoclonal Antibody Against Human Podoplanin.

    Science.gov (United States)

    Yamada, Shinji; Ogasawara, Satoshi; Kaneko, Mika K; Kato, Yukinari

    2017-04-01

    Human podoplanin (hPDPN), the ligand of C-type lectin-like receptor-2, is involved in cancer metastasis. Until now, many monoclonal antibodies (mAbs) have been established against hPDPN. However, it is still difficult to develop a cancer-specific mAb (CasMab) against hPDPN because the protein sequence of hPDPN expressed in cancer cells is the same as that in normal cells. Herein, we report LpMab-23 of the mouse IgG 1 subclass, a novel CasMab against hPDPN. In an immunohistochemical analysis, LpMab-23 reacted with tumor cells of human oral cancer, but did not react with normal cells such as lymphatic endothelial cells (LECs). In contrast, LpMab-17, another anti-hPDPN mAb, reacted with both tumor cells and LECs. Furthermore, flow cytometric analysis revealed that LpMab-23 reacted with hPDPN-expressing cancer cell lines (LN319, RERF-LC-AI/hPDPN, Y-MESO-14/hPDPN, and HSC3/hPDPN) but showed little reaction with normal cells (LECs and HEK-293T), although another anti-hPDPN mAb, LpMab-7, reacted with both hPDPN-expressing cancer cells and normal cells, indicating that LpMab-23 is a CasMab against hPDPN.

  4. Genetic invalidation of Lp-PLA2 as a therapeutic target

    DEFF Research Database (Denmark)

    Gregson, John M; Freitag, Daniel F; Surendran, Praveen

    2017-01-01

    AIMS: Darapladib, a potent inhibitor of lipoprotein-associated phospholipase A2 (Lp-PLA2), has not reduced risk of cardiovascular disease outcomes in recent randomized trials. We aimed to test whether Lp-PLA2 enzyme activity is causally relevant to coronary heart disease. METHODS: In 72...... (Val379Ala (rs1051931)) in PLA2G7, the gene encoding Lp-PLA2. We supplemented de-novo genotyping with information on a further 45,823 coronary heart disease patients and 88,680 controls in publicly available databases and other previous studies. We conducted a systematic review of randomized trials...... to compare effects of darapladib treatment on soluble Lp-PLA2 activity, conventional cardiovascular risk factors, and coronary heart disease risk with corresponding effects of Lp-PLA2-lowering alleles. RESULTS: Lp-PLA2 activity was decreased by 64% (p = 2.4 × 10(-25)) with carriage of any of the four loss...

  5. The Anatomical Correlation between the Internal Venous Vertebral System and the Cranial Venae Cavae in Rabbit.

    Science.gov (United States)

    Mazensky, David; Petrovova, Eva; Danko, Jan

    2013-01-01

    The aim of this study was to describe the possible variations in the connection between the internal venous vertebral system and the cranial vena cava in rabbit using corrosion technique. The study was carried out on 40 adult New Zealand white rabbits. The venous system was injected by using Batson's corrosion casting kit number 17. We found the connection between the internal venous vertebral system and the cranial vena cava by means of the vertebral veins and the right azygos vein. The vertebral vein was present as independent tributary in 36 cases (90%). In the rest of the cases, it was found as being double, being triple, or forming a common trunk with other veins. The azygos vein was present as independent tributary of the cranial vena cava in 39 cases (97.5%). We found also a common trunk formed by the junction of the deep cervical vein, the right vertebral vein, and the azygos vein in one case (2.5%). The azygos vein received 6, 7, 8, or 9 pairs of dorsal intercostal veins. Documenting the anatomical variations in the rabbit will aid in the planning of future experimental studies and determining the clinical relevance on such studies.

  6. The Anatomical Correlation between the Internal Venous Vertebral System and the Cranial Venae Cavae in Rabbit

    Directory of Open Access Journals (Sweden)

    David Mazensky

    2013-01-01

    Full Text Available The aim of this study was to describe the possible variations in the connection between the internal venous vertebral system and the cranial vena cava in rabbit using corrosion technique. The study was carried out on 40 adult New Zealand white rabbits. The venous system was injected by using Batson's corrosion casting kit number 17. We found the connection between the internal venous vertebral system and the cranial vena cava by means of the vertebral veins and the right azygos vein. The vertebral vein was present as independent tributary in 36 cases (90%. In the rest of the cases, it was found as being double, being triple, or forming a common trunk with other veins. The azygos vein was present as independent tributary of the cranial vena cava in 39 cases (97.5%. We found also a common trunk formed by the junction of the deep cervical vein, the right vertebral vein, and the azygos vein in one case (2.5%. The azygos vein received 6, 7, 8, or 9 pairs of dorsal intercostal veins. Documenting the anatomical variations in the rabbit will aid in the planning of future experimental studies and determining the clinical relevance on such studies.

  7. Vena cava filter placement via the antecubital access: a report of 6 cases

    International Nuclear Information System (INIS)

    Yu Bo; Shi Weihao; He Qing; Wang Tieping; Wang Wei

    2008-01-01

    Objective: To study the methods and skill of vena cava filter placement via the antecubital access. Methods: Six patients with DVT (4 males and 2 females, mean age of 62) underwent vena cava filter placement via the antecubital access in Huashan Hospital from Oct. 2004 to May. 2006. The right basilic vein was punctured with the use of micropuncture technique. SNF(Simon nitinol filter, Bard)was inserted through its carrier into the 90-cm-long sheath. The filter was then deployed with a standard fashion in the IVC, 5 cm inferior to the renal vein. Results: The filter was once placed successfully in all six patients within average time of 25 min without complications, but with good healing, exclusion of bleeding and no phlebitis. The position of filter was accurate without deviation and no occurrence of pulmonary embolism. Conclusions: vena cava filter placement via antecubital access is easy, minimal invasive, no need of lying in bed postoperatively. It is beneficial for DVT patients as an alternative for the contra-indication to femoral venous access. (authors)

  8. Primitive neuroectodermal tumour of the kidney with vena caval and atrial tumour thrombus: a case report

    Directory of Open Access Journals (Sweden)

    Ong Poh

    2008-08-01

    Full Text Available Abstract Introduction Renal primitive neuroectodermal tumour is an extremely rare malignancy. Case presentation A 21-year-old woman presented with microscopic haematuria, a palpable right loin mass, dyspnoea, dizziness and fatigue. Initial ultrasound scan of the kidneys revealed an 11 cm right renal mass with venous extension into the inferior vena cava. Computed tomography of the thorax and abdomen revealed an extension of the large renal mass into the right renal vein, inferior vena cava and up to the right atrium. A small paracaval lymph node was noted and three small metastatic nodules were identified within the lung parenchyma. The patient underwent a radical nephrectomy and inferior vena caval tumour (level IV thrombectomy with cardiopulmonary bypass and deep hypothermic circulatory arrest. Immunohistochemical staining of the specimen showed a highly specific cluster of differentiation (CD 99, thus confirming the diagnosis of a primitive neuroectodermal tumour. Conclusion It is important that a renal primitive neuroectodermal tumour be considered, particularly in young patients with a renal mass and extensive thrombus.

  9. [Clinical analysis of patients with lower extremity deep venous thrombosis complicated with inferior vena cava thrombus].

    Science.gov (United States)

    Dong, Dian-ning; Wu, Xue-jun; Zhang, Shi-yi; Zhong, Zhen-yue; Jin, Xing

    2013-06-04

    To explore the clinical profiles of patients with lower extremity deep venous thrombosis (DVT) complicated with inferior vena cava (IVC) thrombus and summarize their clinical diagnostic and therapeutic experiences. The clinical characteristics, diagnosis and treatment of 20 hospitalized patients with DVT complicated with inferior vena cava thrombus were analyzed retrospectively. All of them were of proximal DVT. There were phlegmasia cerulea dolens (n = 3), pulmonary embolism (n = 3) and completely occlusion of IVC (n = 5). Clinical manifestations were severe. Retrievable inferior vena cava filter (IVCF) was implanted for 17 cases. Catheter-directed thrombolysis (CDT) through ipsilateral popliteal vein was applied for 7 cases and systemic thrombolysis therapy for 8 cases. The effective rate of thrombolysis for fresh IVC thrombus was 100%. Among 5 cases with Cockett Syndrome, 3 cases underwent balloon dilatation angioplasty and endovascular stenting of iliac vein. And 17 IVCFs were retrieved successfully within 3 weeks. IVC thrombus disappeared completely in 15 cases. Systemic or local thrombolysis with protective IVCF is a safe and effective therapy for nonocclusive IVC thrombus in DVT. And CDT is recommended for symptomatic occlusive IVC thrombus.

  10. Early and Late Retrieval of the ALN Removable Vena Cava Filter: Results from a Multicenter Study

    International Nuclear Information System (INIS)

    Pellerin, O.; Barral, F. G.; Lions, C.; Novelli, L.; Beregi, J. P.; Sapoval, M.

    2008-01-01

    Retrieval of removable inferior vena cava (IVC) filters in selected patients is widely practiced. The purpose of this multicenter study was to evaluate the feasibility and results of percutaneous removal of the ALN removable filter in a large patient cohort. Between November 2003 and June 2006, 123 consecutive patients were referred for percutaneous extraction of the ALN filter at three centers. The ALN filter is a removable filter that can be implanted through a femoral/jugular vein approach and extracted by the jugular vein approach. Filter removal was attempted after an implantation period of 93 ± 15 days (range, 6-722 days) through the right internal jugular vein approach using the dedicated extraction kit after control inferior vena cavography. Following filter removal, vena cavograms were obtained in all patients. Successful extraction was achieved in all but one case. Among these successful retrievals, additional manipulation using a femoral approach was needed when the apex of the filter was close to the IVC wall in two patients. No immediate IVC complications were observed according to the postimplantation cavography. Neither technical nor clinical differences between early and late filter retrieval were noticed. Our data confirm the safety of ALN filter retrieval up to 722 days after implantation. In infrequent cases, additional endovenous filter manipulation is needed to facilitate extraction.

  11. Leiomyosarcoma of the inferior vena cava level II involvement: curative resection and reconstruction of renal veins

    Directory of Open Access Journals (Sweden)

    Wang Quan

    2012-06-01

    Full Text Available Abstract Leiomyosarcoma of the inferior vena cava (IVCL is a rare retroperitoneal tumor. We report two cases of level II (middle level, renal veins to hepatic veins IVCL, who underwent en bloc resection with reconstruction of bilateral or left renal venous return using prosthetic grafts. In our cases, IVCL is documented to be occluded preoperatively, therefore, radical resection of tumor and/or right kidney was performed and the distal end of inferior vena cava was resected and without caval reconstruction. None of the patients developed edema or acute renal failure postoperatively. After surgical resection, adjuvant radiation therapy was administrated. The patients have been free of recurrence 2 years and 3 months, 9 months after surgery, respectively, indicating the complete surgical resection and radiotherapy contribute to the better survival. The reconstruction of inferior vena cava was not considered mandatory in level II IVCL, if the retroperitoneal venous collateral pathways have been established. In addition to the curative resection of IVCL, the renal vascular reconstruction minimized the risks of procedure-related acute renal failure, and was more physiologically preferable. This concept was reflected in the treatment of the two patients reported on.

  12. Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

    International Nuclear Information System (INIS)

    Hoffer, Eric K.; Mueller, Rebecca J.; Luciano, Marcus R.; Lee, Nicole N.; Michaels, Anne T.; Gemery, John M.

    2013-01-01

    PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters

  13. Safety and Efficacy of the Gunther Tulip Retrievable Vena Cava Filter: Midterm Outcomes

    Energy Technology Data Exchange (ETDEWEB)

    Hoffer, Eric K., E-mail: eric.k.hoffer@hitchcock.org; Mueller, Rebecca J.; Luciano, Marcus R.; Lee, Nicole N.; Michaels, Anne T.; Gemery, John M. [Dartmouth-Hitchcock Medical Center, Department of Radiology, Section of Vascular and Interventional Radiology (United States)

    2013-08-01

    PurposeTo evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter.MethodsA retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59 % were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86 % of patients; 14 % were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records.ResultsMean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3 %). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4 %). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8 %) at a mean of 731 days revealed a single (0.3 %) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5 %), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4 %) at a mean 757 days.ConclusionThe Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

  14. Safety and efficacy of the Gunther Tulip retrievable vena cava filter: midterm outcomes.

    Science.gov (United States)

    Hoffer, Eric K; Mueller, Rebecca J; Luciano, Marcus R; Lee, Nicole N; Michaels, Anne T; Gemery, John M

    2013-08-01

    To evaluate of the medium-term integrity, efficacy, and complication rate associated with the Gunther Tulip vena cava filter. A retrospective study was performed of 369 consecutive patients who had infrarenal Gunther Tulip inferior vena cava filters placed over a 5-year period. The mean patient age was 61.8 years, and 59% were men. Venous thromboembolic disease and a contraindication to or complication of anticoagulation were the indications for filter placement in 86% of patients; 14% were placed for prophylaxis in patients with a mean of 2.3 risk factors. Follow-up was obtained by review of medical and radiologic records. Mean clinical follow-up was 780 days. New or recurrent pulmonary embolus occurred in 12 patients (3.3%). New or recurrent deep-vein thrombosis occurred in 53 patients (14.4%). There were no symptomatic fractures, migrations, or caval perforations. Imaging follow-up in 287 patients (77.8%) at a mean of 731 days revealed a single (0.3%) asymptomatic fracture, migration greater than 2 cm in 36 patients (12.5%), and no case of embolization. Of 122 patients with CT scans, asymptomatic perforations were identified in 53 patients (43.4%) at a mean 757 days. The Gunther Tulip filter was safe and effective at 2-year follow-up. Complication rates were similar to those reported for permanent inferior vena cava filters.

  15. Retrievable Vena Cava Filters in Major Trauma Patients: Prevalence of Thrombus Within the Filter

    International Nuclear Information System (INIS)

    Mahrer, Arie; Zippel, Douglas; Garniek, Alexander; Golan, Gil; Bensaid, Paul; Simon, Daniel; Rimon, Uri

    2008-01-01

    The purpose of this study was to report the prevalence of thrombus within a retrievable vena cava filter inserted prophylactically in major trauma patients referred for filter extraction. Between November 2002 and August 2005, 80 retrievable inferior vena cava filters (68 Optease and 12 Gunther-Tulip) were inserted into critically injured trauma patients (mean injury severity score 33.5). The filters were inserted within 1 to 6 (mean 2) days of injury. Thirty-seven patients were referred for filter removal (32 with Optease and 5 with Gunther-Tulip). The indwelling time was 7 to 22 (mean 13) days. All patients underwent inferior vena cavography prior to filter removal. There were no insertion-related complications and all filters were successfully deployed. Forty-three (54%) of the 80 patients were not referred for filter removal, as these patients continued to have contraindications to anticoagulation. Thirty-seven patients (46%) were referred for filter removal. In eight of them (22%) a large thrombus was seen within the filters and they were left in place, all with the Optease device. The other 29 filters (36%) were removed uneventfully.We conclude that the relatively high prevalence of intrafilter thrombi with the Optease filter may be explained by either spontaneous thrombus formation or captured emboli.

  16. Does Service Innovation Matter in High-Tech Industry

    Directory of Open Access Journals (Sweden)

    Chao-Hung Wang

    2014-05-01

    Full Text Available Service innovation has been found to be a major driver of innovation performance in service contexts. But this issue raises questions concerning the extent to which the relationship between market orientation and innovation performance holds in the high-tech industry. Relatively little research has examined how market orientation contributes to innovation performance through service innovation. We here report an empirical study of 235 Taiwanese high-tech firms to examine the influence of market orientation on service innovation and innovation performance. A noteworthy finding is that the impacts of customer orientation and competitor orientation on innovation performance are fully mediated by service innovation. However, service innovation does only partially mediate the relationship between inter-functional orientation and innovation performance. The findings of this study should help managers consider appropriate service innovation in high-tech industry.

  17. HT-LP thermometamorphism modelling : Agly massif, French Pyrenees.

    Science.gov (United States)

    Tournaire Guille, Baptiste; Pascal, Marie-Lola; Lejeune, Anne-Marie; Annen, Catherine

    2017-04-01

    Owing to the strongly anomalous thermal gradients implied, HT-LP metamorphism is a worldwide type of processes in which magma emplacement and solidification at relatively high levels in the crust must be considered as a potentially major heat source. Thermal modelling (e.g. Annen et al. 2005) is an appropriate tool for constraining the part played by such processes in practical cases of thermometamorphism. We study the Agly massif, an exhumed part of middle crust from the Variscan belt in the French Pyrenees. This massif is a classical example of HT-LP metamorphism (Vielzeuf 1996), composed of a metasedimentary cover, mainly micaschists aged from upper Cambrian to Devonian, unconformably overlying an older basement of para- and orthogneisses. The Variscan metamorphic facies extend from greenschists, in the upper part of the cover, to granulites in the basement (Fonteilles 1976). The apparent geotherm of about 110°/km in the metasedimentary cover (amphibolite and greenschist facies) has given way to contrasting interpretations. Magmatic activity partly synchronous with and probably related to the Variscan thermometamorphism is observed at the outcropping level as at least 4 magmatic bodies of mantle origin (Touil 1994), of Stephanian age, including granodiorites and subordinate diorites and gabbros. Recent U/Pb datations on zircons (Tournaire-Guille et al., in prep) also reveal the presence of lower Cambrian magmatism in the gneisses, therefore confirming their interpretation as a pre-Variscan basement. The location (depth), volume (thickness), temperature (composition) and timing of magma emplacement are the parameters controlling the thermal effect to be modelled with a Matlab® code (Annen et al. 2005). In order to constrain these parameters, we have updated the lithostratigraphy and the PT conditions of the Variscan metamorphism in the Agly area. Mineralogic and petrologic data exploited in thermobarometric analyses compared with thermodynamic PerpleX modelling

  18. 78 FR 14359 - Verizon Business Networks Services, Inc., Specialist-Tech Customer Service, Philadelphia, PA...

    Science.gov (United States)

    2013-03-05

    ... Business Networks Services, Inc., Specialist-Tech Customer Service, Philadelphia, PA; Verizon Business Networks Services, Inc., Specialist-Tech Customer Service, Tampa, Florida; Amended Certification Regarding... should [[Page 14360

  19. Get on Board the Cost Effective Way: A Tech Prep Replication Process.

    Science.gov (United States)

    Moore, Wayne A.; Szul, Linda F.; Rivosecchi, Karen

    1997-01-01

    The Northwestern Pennsylvania Tech Prep Consortium model for replicating tech prep programs includes these steps: fact finding, local industry analysis, curriculum development, detailed description, marketing strategies, implementation, and program evaluation. (SK)

  20. Second public meeting of Governor Kaine's Independent Virginia Tech Incident Review Panel

    OpenAIRE

    Owczarski, Mark

    2007-01-01

    The second public meeting of Governor Kaine's Independent Virginia Tech Incident Review Panel will convene on Monday, May 21, at The Inn at Virginia Tech and Skelton Conference Center Latham Ballroom, 901 Prices Fork Road in Blacksburg.

  1. Virginia Tech's K-9 unit to receive Kevlar vest from alumni organization

    OpenAIRE

    Dickerson, Susan

    2004-01-01

    Hokie, the Virginia Tech Police Department's German shepherd, will be presented with a custom-fitted Virginia Tech Kevlar bulletproof vest to protect him from all the dangers he faces while performing his daily duties.

  2. Endobronchial Forceps-Assisted and Excimer Laser-Assisted Inferior Vena Cava Filter Removal: The Data, Where We Are, and How It Is Done.

    Science.gov (United States)

    Chen, James X; Montgomery, Jennifer; McLennan, Gordon; Stavropoulos, S William

    2018-06-01

    The recognition of inferior vena cava filter related complications has motivated increased attentiveness in clinical follow-up of patients with inferior vena cava filters and has led to development of multiple approaches for retrieving filters that are challenging or impossible to remove using conventional techniques. Endobronchial forceps and excimer lasers are tools for designed to aid in complex inferior vena cava filter removals. This article discusses endobronchial forceps-assisted and excimer laser-assisted inferior vena cava filter retrievals. Copyright © 2018 Elsevier Inc. All rights reserved.

  3. FinTech transformation: how it-enabled innovations shape the financial sector

    OpenAIRE

    Zavolokina, Liudmila; Dolata, Mateusz; Schwabe, Gerhard

    2016-01-01

    FinTech, the phenomenon which spans over the areas of information technologies and financial innovation, is currently on the rise and is gaining more and more attention from practitioners, investors and researchers. FinTech is broadly discussed by the media, which constitutes its understanding and represents social opinion, however, this perception of FinTech should be supported by empirical evidences. Therefore, we examine five Swiss FinTech companies through the lens of the conceptual frame...

  4. Sib-pair analysis detects elevated Lp(a) levels and large variation of Lp(a) concentration in subjects with familial defective ApoB

    NARCIS (Netherlands)

    van der Hoek, Y. Y.; Lingenhel, A.; Kraft, H. G.; Defesche, J. C.; Kastelein, J. J.; Utermann, G.

    1997-01-01

    Whether or not Lp(a) plasma levels are affected by the apoB R3500Q mutation, which causes Familial Defective apoB (FDB), is still a matter of debate. We have analyzed 300 family members of 13 unrelated Dutch index patients for the apoB mutation and the apolipoprotein(a) [apo(a)] genotype. Total

  5. Displacement in new economy labor markets: Post-displacement wage loss in high tech versus low tech cities.

    Science.gov (United States)

    Davis, Daniel J; Rubin, Beth A

    2016-11-01

    While scholars and politicians tout education as the salve to employment disruptions, we argue that the geography of the new economy, and the social closure mechanisms that geography creates, may be just as important as individuals' characteristics for predicting post-displacement wage loss (or gain). We use data from the 2012 Displaced Workers ement of the Current Population Survey and from the 2010 United States Census to test hypotheses linking local labor markets in different industrial contexts to post-displacement wage loss. Our results point to age as a closure mechanism, and to the partially protective effect of education in high-tech versus low-tech economic sectors. This study is the first to use national level data to examine how employment in high-tech cities influences post-displacement wages. These findings are relevant both for theorizing about the new economy and for public policy. Copyright © 2016 Elsevier Inc. All rights reserved.

  6. Using digital tech to improve life for refugees | IDRC - International ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    2016-12-20

    Dec 20, 2016 ... Using digital tech to improve life for refugees ... and netbooks - can help to close the access and quality-of-service gaps for Palestinians ... individuals to enjoy more accessible and better quality health care on a continuous basis. ... health challenges by bringing life-saving information to those most in need.

  7. Virginia Tech Wildlife Professor Helping To Save Florida Panther

    OpenAIRE

    Davis, Lynn

    2003-01-01

    With few Florida panthers now in existence, Mike Vaughan, Virginia Tech professor of wildlife and sciences in the College of Natural Resources, has been appointed to serve on the Florida Panther Scientific Review Team (SRT). Vaughan and other SRT members have made several trips to Naples, Fla., to interview state and federal biologists directly involved with the recovery of the Florida panther.

  8. Tech Team: Student Technology Assistants in the Elementary & Middle School.

    Science.gov (United States)

    Peto, Erica; Onishi, Esther; Irish, Barbara

    A step-by-step manual of worksheets, templates, forms and examples, this comprehensive handbook is designed for librarians, classroom teachers, and technology specialists who are interested in training students to be technology aides. The "Tech Team" program not only systematically outlines how one organizes and manages a support program, but…

  9. Virginia Tech's College Of Natural Resources Dedicates Cheatham Hall Expansion

    OpenAIRE

    Davis, Lynn

    2003-01-01

    Thanks to funding by private donors, Alyce Cheatham and her family of Portland, Oregon, Virginia Tech's College of Natural Resources will dedicate a much-needed, three-story addition to its current Cheatham Hall on Wednesday, March 19, at 2:30 p.m.

  10. Online Classes See Cheating Go High-Tech

    Science.gov (United States)

    Young, Jeffrey R.

    2012-01-01

    Easy A's may be even easier to score these days, with the growing popularity of online courses. Tech-savvy students are finding ways to cheat that let them ace online courses with minimal effort, in ways that are difficult to detect. The issue of online cheating may rise in prominence, as more and more institutions embrace online courses, and as…

  11. Development of a data capture tool for researching tech entrepreneurship

    DEFF Research Database (Denmark)

    Andersen, Jakob Axel Bejbro; Howard, Thomas J.; McAloone, Tim C.

    2014-01-01

    . This paper elucidates the requirements for such tools by drawing on knowledge of the entrepreneurial phenomenon and by building on the existing research tools used in design research. On this basis, the development of a capture method for tech startup processes is described and its potential discussed....

  12. CHARCOAL PACKED FURNACE FOR LOW-TECH CHARRING OF BONE

    DEFF Research Database (Denmark)

    Jacobsen, P.; Dahi, Elian

    1997-01-01

    A low-tech furnace for charring of raw bone using char coal is developed and tested. The furnace consists of a standard oil drum, fitted with simple materials as available in every market in small towns in developing counties. 80 kg of raw bone and 6 kg of charcoal are used for production of 50 kg...

  13. Ten Niche Strategies To Commercialize New High-Tech Products

    NARCIS (Netherlands)

    Ortt, J.R.; Langley, D.J.; Pals, N.

    2013-01-01

    There are serious gaps in the scientific literature relating to niche strategies as a means for commercializing new high-tech products. In particular, there is no clarity about what types of niche strategies can be distinguished, or how a niche strategy can be selected to suit a certain ituation. In

  14. Perceptions of Diversity Training Needs in High Tech Business.

    Science.gov (United States)

    Lieberman, Devorah A.; Gurtov, Ellene

    A study questioned 12 human resource personnel, corporation managers, and diversity trainers about their perceptions of diversity training needs in Pacific Northwest high tech organizations. The overarching research questions for the study were as follows: (1) What are the most frequently reported diversity training needs among human resource…

  15. Florida Tech professor gets three-year grant

    CERN Multimedia

    2003-01-01

    "Dr. Marc Baarmand, Florida Tech associate professor of physics, has received a three-year grant from the U.S. Department of Energy's Division of High Energy Physics, to conduct research with the Compact Muon Solenoid experiment" (1/3 page).

  16. 76 FR 68243 - Youth Leadership Program: TechGirls

    Science.gov (United States)

    2011-11-03

    ..., job shadowing, mini-internships, and/or site visits to high tech companies in the United States... Exempt From Income Tax,'' must include a copy of relevant portions of this form. (2) Those who do not... participants or partners and be able to respond to key evaluation questions, including satisfaction with the...

  17. High Touch in a High-Tech World

    Science.gov (United States)

    Gibson, Cindy L.

    2009-01-01

    In a world of high tech and low touch, it is easy for public relations programs to stray from tried-and-true interpersonal strategies long associated with solid communication planning. New technologies allow communications professionals to quickly send e-mails and telephone calls to selected groups. Social media sites provide users immediate…

  18. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  19. Analysis of error floor of LDPC codes under LP decoding over the BSC

    Energy Technology Data Exchange (ETDEWEB)

    Chertkov, Michael [Los Alamos National Laboratory; Chilappagari, Shashi [UNIV OF AZ; Vasic, Bane [UNIV OF AZ; Stepanov, Mikhail [UNIV OF AZ

    2009-01-01

    We consider linear programming (LP) decoding of a fixed low-density parity-check (LDPC) code over the binary symmetric channel (BSC). The LP decoder fails when it outputs a pseudo-codeword which is not a codeword. We propose an efficient algorithm termed the instanton search algorithm (ISA) which, given a random input, generates a set of flips called the BSC-instanton and prove that: (a) the LP decoder fails for any set of flips with support vector including an instanton; (b) for any input, the algorithm outputs an instanton in the number of steps upper-bounded by twice the number of flips in the input. We obtain the number of unique instantons of different sizes by running the ISA sufficient number of times. We then use the instanton statistics to predict the performance of the LP decoding over the BSC in the error floor region. We also propose an efficient semi-analytical method to predict the performance of LP decoding over a large range of transition probabilities of the BSC.

  20. TRAINING EMPLOYEES TO WORK WITH HI-TECH EQUIPMENT

    Directory of Open Access Journals (Sweden)

    M. A. Dremina

    2016-01-01

    Full Text Available The aim of the study is to describe a research relying on the capabilities of networking, which improves the quality of vocational training of skilled workers that are intended to work with new hi-tech equipment.Methods. Methods of system and comparative analysis, modeling, synthesis and generalization are used. Specification of the model of workers training offered by authors is carried out on the basis of deep interviews to experts – the representatives of the large enterprises who are carrying out training of the personnel.Results. Social and pedagogical contradictions are revealed, on the one hand, in the growing need for highly professional personnel for hi-tech productions, and, on the other hand, in insufficiently effective countermeasures of the system of vocational education and training on closing actual requirements of productions. The discrepancies reducing the quality of preparation of skilled workers are revealed by comparative analysis of competences based on an ideal competence model of the trainer and teacher of VET with the competences presented in educational both professional standards and the discussed projects. Characteristics of the existing pedagogical process in the hi-tech production environment are described. For the purpose of quality improvement of the pedagogical process, the network format of interactions of the enterprise, educational and the business organizations is offered.Scientific novelty. The concept «pedagogical process» for the purpose of making it more instrumental is specified; it joins a technological process and the design of its ideal model for the hi-tech production environment. The unique network project including design and development of innovative manuals and teaching materials for the welding equipment of Fronius International GmbH.Practical significance. The research results can be useful to the management of staff development and career advancement of hi-tech productions, and VET

  1. Circulating and PBMC Lp-PLA2 associate differently with oxidative stress and subclinical inflammation in nonobese women (menopausal status.

    Directory of Open Access Journals (Sweden)

    Jean Kyung Paik

    Full Text Available BACKGROUND: This study aimed to determine the association of lipoprotein-associated phospholipase A(2 (Lp-PLA(2 activity in circulation and peripheral blood mononuclear cells (PBMCs with inflammatory and oxidative stress markers in nonobese women and according to menopausal status. Lp-PLA(2 activity, a marker for cardiovascular risk is associated with inflammation and oxidative stress. METHODOLOGY/PRINCIPAL FINDINGS: Eighty postmenopausal women (53.0±4.05 yr and 96 premenopausal women (39.7±9.25 yr participated in this study. Lp-PLA(2 activities, interleukin (IL-6, tumor necrosis factor (TNF-α, and IL-1β in plasma as well as in PBMCs were measured. Plasma ox-LDL was also measured. Postmenopausal women demonstrated higher circulating levels of ox-LDL and IL-6, as well as IL-6, TNF-α, and IL-1β in PBMCs, than premenopausal women. In both groups, plasma Lp-PLA(2 activity positively correlated with Lp-PLA(2 activity in PBMCs and plasma ox-LDL. In premenopausal women, Lp-PLA(2 activities in plasma and PBMCs positively correlated with IL-6, TNF-α, and IL-1β in PBMCs. In postmenopausal women, plasma ox-LDL positively correlated with PBMC cytokine production. In subgroup analysis of postmenopausal women according to plasma ox-LDL level (median level: 48.715 U/L, a significant increase in Lp-PLA(2 activity in the plasma but not the PBMCs was found in the high ox-LDL subgroup. Plasma Lp-PLA(2 activity positively correlated with unstimulated PBMC Lp-PLA(2 activity in the low ox-LDL subgroup (r = 0.627, P<0.001, whereas in the high ox-LDL circulating Lp-PLA(2 activity positively correlated with plasma ox-LDL (r = 0.390, P = 0.014 but not with Lp-PLA(2 activity in PBMCs. CONCLUSIONS/SIGNIFICANCE: The lack of relation between circulating Lp-PLA(2 activity and Lp-PLA(2 activity in PBMCs was found in postmenopausal women with high ox-LDL. This may indicate other sources of circulating Lp-PLA(2 activity except PBMC in postmenopausal women

  2. FinTech in Taiwan: a case study of a Bank's strategic planning for an investment in a FinTech company

    OpenAIRE

    Hung, Jui-long; Luo, Binjie

    2016-01-01

    Introduction: Since 2015 is the year of FinTech in Taiwan, it is worth investigating the challenges that emerged when banks were encouraged to invest in FinTech companies for collaboration. This study aims to identify the strategic considerations in the process of searching for FinTech investment targets. Case description: This study used a case study investigation of a top-5 bank in Taiwan. The major data sources include the meeting notes of the FinTech investment task force and interviews w...

  3. Protocol of an expertise based randomized trial comparing surgical Venae Sectio versus radiological Puncture of Vena Subclavia for insertion of Totally Implantable Access Port in oncological patients

    Directory of Open Access Journals (Sweden)

    Radeleff Boris

    2008-10-01

    Full Text Available Abstract Background Totally Implantable Access Ports (TIAP are being extensively used world-wide and can be expected to gain further importance with the introduction of new neoadjuvant and adjuvant treatments in oncology. Two different techniques for the implantation can be selected: A direct puncture of a central vein and the utilization of a Seldinger device or the surgical Venae sectio. It is still unclear which technique has the optimal benefit/risk ratio for the patient. Design A single-center, expertise based randomized, controlled superiority trial to compare two different TIAP implantation techniques. 100 patients will be included and randomized pre-operatively. All patients aged 18 years or older scheduled for primary elective implantation of a TIAP under local anesthesia who signed the informed consent will be included. The primary endpoint is the primary success rate of the randomized technique. Control Intervention: Venae Sectio will be employed to insert a TIAP by a surgeon; Experimental intervention: Punction of V. Subclavia will be used to place a TIAP by a radiologist. Duration of study: Approximately 10 months, follow up time: 90 days. Organisation/Responsibility The PORTAS 2 – Trial will be conducted in accordance with the protocol and in compliance with the moral, ethical, and scientific principles governing clinical research as set out in the Declaration of Helsinki (1989 and Good Clinical Practice (GCP. The Center of Clinical Trials at the Department of Surgery, University Hospital Heidelberg is responsible for design and conduct of the trial including randomization and documentation of patients' data. Data management and statistical analysis will be performed by the independent Institute for Medical Biometry and Informatics (IMBI, University of Heidelberg. Trial Registration The trial is registered at ClinicalTrials.gov (NCT00600444.

  4. AspenTech shows specific tools for refiners; AspenTech deploie des outils specifiques pour les raffineurs

    Energy Technology Data Exchange (ETDEWEB)

    Legros, E

    2003-10-01

    The supplier of integrated softwares AspenTech has organized last May, the 7 in Gelsenkirchen, on the site of the Veba Oel refinery, a seminar 'refining' intended to show the specificities of its products: Hysys, Aspen Utilities, Icarus...About fifty German engineers and responsible persons coming from refining and engineering firms have participated to this studies day. (O.M.)

  5. Acute iliofemoral venous thrombosis in patients with atresia of the inferior vena cava can be treated successfully with catheter-directed thrombolysis

    DEFF Research Database (Denmark)

    Broholm, Rikke; Jørgensen, Maja; Just, Sven

    2011-01-01

    To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT).......To assess the effectiveness and clinical outcomes of catheter-directed thrombolysis in patients with atresia of the inferior vena cava (IVC) and acute iliofemoral deep vein thrombosis (DVT)....

  6. Tratamento da síndrome da veia cava superior Treatment of superior vena cava syndrome

    Directory of Open Access Journals (Sweden)

    Luís Marcelo Inaco Cirino

    2005-12-01

    Full Text Available A veia cava superior é formada pela união das duas veias inominadas, direita e esquerda, e localiza-se no mediastino médio, à direita da artéria aorta e anteriormente à traquéia. A síndrome da veia cava superior representa um conjunto de sinais (dilatação das veias do pescoço, pletora facial, edema de membros superiores, cianose e sintomas (cefaléia, dispnéia, tosse, edema de membro superior, ortopnéia e disfagia decorrentes da obstrução do fluxo sanguíneo através da veia cava superior em direção ao átrio direito. A obstrução pode ser causada por compressão extrínseca, invasão tumoral, trombose ou por dificuldade do retorno venoso ao coração secundária a doenças intra-atriais ou intraluminais. Aproximadamente 73% a 97% dos casos de síndrome da veia cava superior ocorrem durante a evolução de processos malignos intratorácicos. A maioria dos pacientes com a síndrome secundária a neoplasias malignas é tratada sem necessidade de cirurgia, através de radioterapia ou quimioterapia, ou através da colocação de stents endoluminais. Quando a síndrome é de etiologia benigna, o tratamento é feito através de medidas clínicas (anticoagulação, elevação da cabeça, etc. ou, em casos refratários, através de angioplastia, colocação de stents endoluminais e cirurgia.The superior vena cava is formed by the union of the right and left brachiocephalic veins. It is located in the middle mediastinum, to the right of the aorta and anterior to the trachea. Superior vena cava syndrome consists of a group of signs (dilation of the veins in the neck, facial swelling, edema of the upper limbs, and cyanosis and symptoms (headache, dyspnea, cough, orthopnea and dysphagia caused by the obstruction of blood flow through the superior vena cava to the right atrium. This obstruction can be caused by extrinsic compression, tumor invasion or thrombosis. Such obstruction may also occur as a result of insufficient venous return

  7. Diagnosis of tricuspid insufficiency by Doppler flowmetry in the inferior vena cava. A comparison with right ventricular angiography

    Energy Technology Data Exchange (ETDEWEB)

    Smith, H.J.

    Eighty-five patients subjected to routine heart catheterization were examined with duplex scanning of the inferior vena cava. Adequate Doppler recordings and a right ventricular angiography were obtained in 79 of them. Tricuspid insufficiency was found to be present in 34 patients at angiography and in 24 at duplex examination. No false positive Doppler diagnoses of tricuspid insufficiency occurred. The possibility of false positive angiographic diagnoses is discussed. A high correlation was found between percentage reversed flow in the inferior vena cava during ventricular systole and degree of angiographic tricuspid insufficiency. It is concluded that duplex scanning of the inferior vena cava seems to be a good alternative to angiography in the diagnosis and quantification of tricuspid insufficiency.

  8. Long-term success of endovascular treatment of benign superior vena cava occlusion with chylothorax and chylopericardium

    Energy Technology Data Exchange (ETDEWEB)

    Veroux, Pierfrancesco; Veroux, Massimiliano; Bonanno, Maria Giovanna; Tumminelli, Maria Giuseppina [Department of Surgery and Transplantation, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy); Baggio, Elda [Department of Surgery and Gastroenterological Sciences, University Hospital of Verona (Italy); Petrillo, Giuseppe [Department of Radiology, University Hospital, Via S. Sofia, 78, 95123 Catania (Italy)

    2002-07-01

    The most likely etiology of benign obstruction of the superior vena cava (SVC) include fibrosing mediastinitis and iatrogenic etiologies such as sclerosis and obstruction caused by pacemakers and central venous catheter. Percutaneous stenting of SVC has been used with success both in malignant and benign superior vena cava syndrome; however, long-term follow-up of endovascular procedures is not well known. We present a case of a patient with complete occlusion of SVC of benign etiology, presenting dramatically with bilateral chylothorax and chylopericardium with cardiac tamponade, who underwent successful vena caval revascularization with thrombolytic therapy and placement of self-expanding metallic stent. The 42-month follow-up could encourage endovascular procedures even in SVC syndrome of benign etiology. (orig.)

  9. Filtros de vena cava en pacientes con cáncer

    Directory of Open Access Journals (Sweden)

    Fernando A. Díaz Couselo

    2012-08-01

    Full Text Available Los pacientes con tromboembolismo venoso (TEV y cáncer tienen más complicaciones vinculadas al tratamiento anticoagulante que la población general. Los filtros de vena cava constituyen una herramienta útil para el tratamiento del TEV y su utilización es controvertida en estadios avanzados de la enfermedad. En este trabajo se revisaron las indicaciones, complicaciones y frecuencia de retiro de los filtros de vena cava en una población de pacientes oncológicos con TEV. Se analizaron 27 pacientes a quienes se les había colocado filtros de vena cava. Veinticinco tenían tumores sólidos y dos linfomas no Hodgkin. Veinticinco estaban bajo tratamiento activo (cirugía y/o quimioterapia. Diecinueve se hallaban en estadio IV de su enfermedad. El motivo de su indicación fue profilaxis en el período perioperatorio en 14 casos (51.9%, hemorragia (n = 5, trombocitopenia (n = 4, metástasis en sistema nervioso central (n = 2, accidente cerebrovascular (n = 1 y neurocirugía previa no reciente (n = 1. Se retiraron 8 (29.6% filtros. La mediana del tiempo de permanencia fue 21 días (6-75. No hubo diferencias estadísticamente significativas en la frecuencia de retiro entre los filtros colocados en el perioperatorio (6/14 y los colocados por otras contraindicaciones para la anticoagulación (2/13; p = 0.2087. No hubo fracasos ni complicaciones en los procedimientos de colocación y retiro.

  10. Indications, complications and outcomes of elderly patients undergoing retrievable inferior vena cava filter placement.

    Science.gov (United States)

    Rottenstreich, Amihai; Kleinstern, Geffen; Bloom, Allan I; Klimov, Alexander; Kalish, Yosef

    2017-10-01

    The utilization of inferior vena cava filter placement for pulmonary embolism prevention in elderly patients has not been well characterized. The present study aimed to review indications, complications and follow-up data of elderly patients undergoing inferior vena cava filter placement. A retrospective review was carried out of consecutive admitted patients who underwent inferior vena cava filter insertion at a large university hospital with a level I trauma center. Overall, 455 retrievable filters were inserted between 2009 and 2014. A total of 133 patients (29.2%) were aged ≥70 years. Elderly patients were less likely to have their filter retrieved compared with non-elderly patients (5.3% vs 21.4%, P Filter-related complications occurred in 13% of non-elderly patients and 14.3% of elderly patients (P = 0.72), most of them occurring in the first 3 months after filter placement. Survival among elderly patients with no evidence of active malignancy was similar to the non-elderly patients with a 1-year survival rate of 76.3% versus 82% in non-elderly patients (P = 0.22), and a 2-year survival rate of 73.1% versus 78.6% in non-elderly patients (P = 0.27). Although decreased, survival rates among elderly patients with active cancer were still substantial, with a 1-year survival rate of 45% and 2-year survival rate of 40%. Elderly patients had significantly lower rates of filter retrieval with similar complication rate. Survival rates among elderly patients were substantial, and in elderly patients with no active cancer were even comparable with non-elderly patients. When feasible, filter retrieval should be attempted in all elderly patients in order to prevent filter-related complications. Geriatr Gerontol Int 2017; 17: 1508-1514. © 2016 Japan Geriatrics Society.

  11. Percutaneous Transluminal Angioplasty for Complete Membranous Obstruction of Suprahepatic Inferior Vena Cava: Long-Term Results

    Energy Technology Data Exchange (ETDEWEB)

    Kucukay, Fahrettin, E-mail: fkucukay@hotmail.com [Turkiye Yuksek Ihtisas Hospital, Department of Interventional Radiology (Turkey); Akdogan, Meral, E-mail: akdmeral@yahoo.com [Turkiye Yuksek Ihtisas Hospital, Department of Gastroenterology (Turkey); Bostanci, Erdal Birol, E-mail: ebbostanci@yahoo.com [Turkiye Yuksek Ihtisas Hospital, Department of Gastrointestinal Surgery (Turkey); Ulus, Ahmet Tulga, E-mail: uluss@yahoo.com [Hacettepe University, Department of Cardiovascular Surgery (Turkey); Kucukay, Murat Bulent, E-mail: dr-mbk@hotmail.com [Lokman Hekim Hospital, Department of Internal Medicine (Turkey)

    2016-10-15

    PurposeTo determine the long-term results of percutaneous transluminal angioplasty (PTA) for a complete membranous obstruction of the suprahepatic inferior vena cava.MethodsPatients (n = 65) who were referred to the interventional unit for PTA for a complete membranous obstruction of the suprahepatic inferior vena cava between January 2006 and October 2014 were included in the study. Thirty-two patients (18 males, 14 females, mean age 35 ± 10.7, range 20–42 years) were treated. The patients presented with symptoms of ascites (88 %), pleural effusion (53 %), varicose veins (94 %), hepatomegaly (97 %), abdominal pain (84 %), and splenomegaly (40 %). Transjugular liver access set and re-entry catheter were used to puncture and traverse the obstruction from the jugular side. PTA balloon dilations were performed. The mean follow-up period was 65.6 ± 24.5 months. The objective was to evaluate technical success, complications, primary patency, and clinical improvement in the symptoms of the patients.ResultsThe technical success rate was 94 %. In two patients, obstruction could not be traversed. These patients underwent cavoatrial graft bypass surgery. There were no procedure-related complications. Clinical improvements were achieved in all patients within 3 months. The primary patency rate at 4 years was 90 %. There was no primary assisted patency. There was no need for metallic stent deployment in the cohort. The secondary patency rate at 4 years was 100 %.ConclusionsPercutaneous transluminal angioplasty for a complete membranous obstruction of the suprahepatic inferior vena cava is safe and effective, and the long-term results are excellent.

  12. Advanced LP turbine installation at 1300 MW nuclear power station Unterweser

    International Nuclear Information System (INIS)

    Jacobsen, G.; Oeynhausen, H.; Termuehlen, H.

    1991-01-01

    This paper reports on Preussen Elektra AG's Unterweser power plant. The steam turbine-generator features a disk-type LP turbine rotor design developed in the late 1960's to early 1970's. This rotor design has been installed in 19 nuclear power plants. The 47 rotors in these plants have been in operation for an average of almost 10 years. The design of the 1970 vintage nuclear LP turbine rotors was based on extensive experience gained with disk-type rotors of fossil turbines built in the 1950's. When EPRI reported about corrosion cracking in nuclear LP turbines, a program was initiated by Siemens/KWU as original steam turbine supplier to ultrasonically inspect all their disk-type rotors in nuclear power plats. Indications on one rotor disk in the Unterweser plant was found. This single event was the only one found out of 310 disks inspected in nuclear power plants

  13. P.S. I love you...and other growth hacking strategies used by disruptive tech start-ups : A case study on the relevance and enactment of growth hacking by Sweden's tech start-ups

    OpenAIRE

    Bergendal, Taghrid Sara

    2017-01-01

    Disruption innovation theory has been the zeitgeist for building globally disruptive tech companies since 1997. One decade later, disruptive tech start-ups are moving away from traditional marketing strategies in favour of growth hacking. There is a seemingly growing consensus by online tech experts, tech entrepreneurs, advisors and investors, that suggests that growth hacking is becoming increasingly important practice for disruption based tech start-ups. Furthermore, Sweden is becoming the ...

  14. Seminoma Presenting as Renal Mass, Inferior Vena Caval Thrombus, and Regressed Testicular Mass

    Directory of Open Access Journals (Sweden)

    Valary T. Raup

    2015-01-01

    Full Text Available Testicular cancer is the most common malignancy of men aged 15–40. Metastatic spread classically begins with involvement of the retroperitoneal lymph nodes, with metastases to the liver, lung, bone, and brain representing advancing disease. Treatment is based on pathologic analysis of the excised testicle and presence of elevated tumor markers. We report a case of a 34-year-old male presenting with back pain who was found to have a right renal mass with tumor extension into the inferior vena cava. Subsequent biopsy was consistent with seminoma. We review this rare case and discuss the literature regarding its diagnosis and management.

  15. Life-threatening Cerebral Edema Caused by Acute Occlusion of a Superior Vena Cava Stent

    International Nuclear Information System (INIS)

    Sofue, Keitaro; Takeuchi, Yoshito; Arai, Yasuaki; Sugimura, Kazuro

    2013-01-01

    A71-year-old man with advanced lung cancer developed a life-threatening cerebral edema caused by the acute occlusion of a superior vena cava (SVC) stent and was successfully treated by an additional stent placement. Although stent occlusion is a common early complication, no life-threatening situations have been reported until now. Our experience highlights the fact that acute stent occlusion can potentially lead to the complete venous shutdown of the SVC, resulting in life-threatening cerebral edema, after SVC stent placement. Immediate diagnosis and countermeasures are required.

  16. Thrombosis of right ovarian vein; Trombosis de la vena ovarica derecha

    Energy Technology Data Exchange (ETDEWEB)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M. [Hospital General Universitario de Valencia. Valencia (Spain)

    2001-07-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs.

  17. Primary Pulmonary Ewing’s Sarcoma: Rare Cause of Superior Vena Cava Syndrome in Children

    OpenAIRE

    Mehra, Shibani; Atwal, Swapndeep Singh; Garga, Umesh Chandra

    2014-01-01

    Ewing’s sarcoma is a common malignant bone tumour presenting in children and young adults. Rarely extra- skeletal soft tissues and visceral organs can also be the site of origin of Ewing’s sarcoma. Primary pulmonary Ewing’s sarcoma is an extremely rare malignancy which occurs in the paediatric population. We report an unusual case of primary pulmonary Ewing’s sarcoma in a nine year old girl who presented with features of superior vena cava syndrome in the emergency department. The diagnosis w...

  18. Renal angiomyolipoma with inferior vena caval thrombus in a 32-year-old male

    Directory of Open Access Journals (Sweden)

    Matthew W Christian

    2009-01-01

    Full Text Available Renal angiomyolipoma (AML rarely presents with evidence of extension into the renal vein, inferior vena cava (IVC or atrium. We report a case of a renal AML with a tumor thrombus to the IVC in a 32-year-old male. The patient subsequently underwent a right radical nephrectomy with IVC tumor thrombectomy. To our knowledge, there are four published cases of renal AML presenting with tumor thrombus in males. This case report describes the management of the youngest male ever to develop a renal AML with IVC tumor thrombus.

  19. Immediate endovascular treatment of an aortoiliac aneurysm ruptured into the inferior vena cava.

    Science.gov (United States)

    Kopp, Reinhard; Weidenhagen, Rolf; Hoffmann, Ralf; Waggershauser, Tobias; Meimarakis, Georgios; Andrassy, Joachim; Clevert, Dirk; Czerner, Stephan; Jauch, Karl-Walter

    2006-07-01

    An aortocaval fistula is a severe complication of an aortoiliac aneurysm, usually associated with high perioperative morbidity and mortality during open operative repair. We describe the successful endovascular treatment of a symptomatic infrarenal aortic aneurysm ruptured into the inferior vena cava with secondary interventional coiling of a persistent type II endoleak because of retrograde perfusion of the inferior mesenteric artery. Endovascular exclusion of ruptured abdominal aneurysms seems to be a valuable treatment option for selected patients even with complicated vascular conditions like an aortocaval fistula.

  20. Fibrosing mediastinitis and thrombosis of superior vena cava associated with Behcet's disease

    International Nuclear Information System (INIS)

    Harman, Mustafa; Sayarlioglu, Mehmet; Arslan, Halil; Ayakta, Hayati; Harman, Ece

    2003-01-01

    We present CT, MRI and venography findings in 13-year boy with mediastinal fibrosis and superior vena cava (SVC) thrombosis associated with Behcet's disease. Fibrosing mediastinitis is an excessive fibrotic reaction that occurs in the mediastinum and may lead to compression of mediastinal structures (especially vascular). This condition is usually idiopathic, though many (and perhaps most) cases in the USA are thought to be caused by an abnormal immunologic response to Histoplasma capsulatum infection. SVC syndrome secondary to extrinsic compression by mediastinal fibrosis combined with Behcet's disease has rarely been described. Radiological investigations of this syndrome are necessary to avoid a useless anticoagulant therapy

  1. Permanent Pacemaker-Induced Superior Vena Cava Syndrome: Successful Treatment by Endovascular Stent

    International Nuclear Information System (INIS)

    Lanciego, Carlos; Rodriguez, Mario; Rodriguez, Adela; Carbonell, Miguel A.; Garcia, Lorenzo Garcia

    2003-01-01

    The use of metallic stents in the management of benign and malignant superior vena cava syndrome (SVCS) is well documented. Symptomatic stenosis or occlusion of the SVC is a rare complication of a transvenous permanent pacemaker implant. Suggested treatments have included anticoagulation therapy, thrombolysis, balloon angioplasty and surgery. More recently, endovascular stenting has evolved as an attractive alternative but the data available in the literature are limited. We describe a case in which venous stenting with a Wallstent endoprosthesis was used successfully. The patient remains symptom free and with normal pacemaker function 36 months later

  2. Primary Pulmonary Ewing's Sarcoma: Rare Cause of Superior Vena Cava Syndrome in Children.

    Science.gov (United States)

    Mehra, Shibani; Atwal, Swapndeep Singh; Garga, Umesh Chandra

    2014-08-01

    Ewing's sarcoma is a common malignant bone tumour presenting in children and young adults. Rarely extra- skeletal soft tissues and visceral organs can also be the site of origin of Ewing's sarcoma. Primary pulmonary Ewing's sarcoma is an extremely rare malignancy which occurs in the paediatric population. We report an unusual case of primary pulmonary Ewing's sarcoma in a nine year old girl who presented with features of superior vena cava syndrome in the emergency department. The diagnosis was confirmed pathologically both by light microscopy and immunohistochemistry. The patient was put on chemotherapy and surgery was planned but the patient expired within three days of starting chemotherapy.

  3. Primary mediastinal melanoma presenting as superior vena cava syndrome: A case study

    Directory of Open Access Journals (Sweden)

    Ann C Gaffey

    2016-03-01

    Full Text Available The rates of melanoma have increased over the past 30 years. Malignant melanoma most commonly occurs in the skin with secondary involvement of other organs. Here, we present an extremely rare case of malignant melanoma of the mediastinum with presentation of superior vena cava syndrome without clinical evidence of extrathoracic disease. The incidence of this clinical presentation is uncommon, resulting in only a handful of case reports in the literature. [Arch Clin Exp Surg 2016; 5(1.000: 56-58

  4. A fractured inferior vena cava filter strut migrating to the left pulmonary artery

    Directory of Open Access Journals (Sweden)

    Tamer Hudali

    2015-01-01

    Full Text Available Inferior vena cava filters are increasingly used in patients with recurrent venous thromboembolism who are contraindicated to anticoagulation. Migration of a broken strut to the pulmonary artery is a very rare complication of these filters. We report the case of an 83-year-old female who experienced this complication with the migratory strut remaining in the same position for years. This case provides evidence that such filters probably have higher rates of complications than what has been thought that remain asymptomatic. The indications and the management of complications of such devices need to be studied further.

  5. Diagnostic value of CRP and Lp(a) in coronary heart disease.

    Science.gov (United States)

    Erbağci, Ayşe Binnur; Tarakçioğlu, Mehmet; Aksoy, Mehmet; Kocabaş, Ramazan; Nacak, Muradiye; Aynacioğlu, A Sükrü; Sivrikoz, Cumhur

    2002-06-01

    Increased lipoprotein (a) [Lp(a)] concentration was reported to be an independent risk factor for coronary heart disease (CHD). Recent epidemiological studies affirmed the value of C-reactive protein (CRP) as the strongest, univariate predictor of the cardiovascular events. We decided to establish cut-off levels providing maximum diagnostic efficiency for CHD. In this study we measured CRP and Lp(a) concentrations in patients with angiographically demonstrated CHD (group A, n: 120), patients without any angiographically demonstrable lesion (group B, n: 62) and a group of healthy subjects (group C, n: 41). Data were evaluated correcting for lipid and lipoprotein concentrations, diabetes mellitus, hypertension, smoking, age, and body mass index in men and women. ROC curve based cut-off values (comparing group A versus groups B and C) and associated diagnostic performances of the assays were evaluated. Significant increases were noted in serum CRP concentrations in men and women, in groups A vs. B,A vs. C, B vs. C. Lp(a) concentrations were not different among groups in men but were higher in group A vs. B and C in women. Optimal cut-off levels for CRP in women and men were found as 2.1 and 3.0 mg/l with the diagnostic values of 0.792 and 0.770, respectively. For Lp(a) optimal cut-off levels were found as 22.6 and 9.8 mg/dl with the diagnostic values of 0.612 and 0.596 in women and men, respectively. The CRP level is quite efficient for separation of patients from controls. Therefore keeping in mind the lack of specificity, the CRP level may be a useful tool in the diagnosis of coronary heart disease. However, the Lp(a) level is not efficient enough to support the use of Lp(a) measurement for management of coronary heart disease.

  6. A spinach O-acetylserine(thiollyase homologue, SoCSaseLP, suppresses cysteine biosynthesis catalysed by other enzyme isoforms

    Directory of Open Access Journals (Sweden)

    Miki Noda

    2016-06-01

    Full Text Available An enzyme, O-acetylserine(thiollyase (OASTL, also known as O-acetylserine sulfhydrylase or cysteine synthase (CSase, catalyses the incorporation of sulfide into O-acetylserine and produces cysteine. We previously identified a cDNA encoding an OASTL-like protein from Spinacia oleracea, (SoCSaseLP, but a recombinant SoCSaseLP produced in Escherichia coli did not show OASTL activity. The exon-intron structure of the SoCSaseLP gene shared conserved structures with other spinach OASTL genes. The SoCSaseLP and a Beta vulgaris homologue protein, KMT13462, comprise a unique clade in the phylogenetic tree of the OASTL family. Interestingly, when the SoCSaseLP gene was expressed in tobacco plants, total OASTL activity in tobacco leaves was reduced. This reduction in total OASTL activity was most likely caused by interference by SoCSaseLP with cytosolic OASTL. To investigate the possible interaction of SoCSaseLP with a spinach cytosolic OASTL isoform SoCSaseA, a pull-down assay was carried out. The recombinant glutathione S-transferase (GST-SoCSaseLP fusion protein was expressed in E. coli together with the histidine-tagged SoCSaseA protein, and the protein extract was subjected to glutathione affinity chromatography. The histidine-tagged SoCSaseA was co-purified with the GST-SoCSaseLP fusion protein, indicating the binding of SoCSaseLP to SoCSaseA. Consistent with this interaction, the OASTL activity of the co-purified SoCSaseA was reduced compared with the activity of SoCSaseA that was purified on its own. These results strongly suggest that SoCSaseLP negatively regulates the activity of other cytosolic OASTL family members by direct interaction.

  7. An LP-based heuristic for the fixed charge transportation problem

    DEFF Research Database (Denmark)

    Klose, Andreas

    2007-01-01

    The fixed charge transportation problem consists in finding a minimum cost network flow from a set of suppliers to a set of customers. Beside costs proportional to quantities transported, transportation costs also include a fixed charge. The paper describes a linear programming based heuristic...... approach for computing lower and upper bounds on the minimal cost. To this end, the LP relaxation is iteratively strengthened by means of adding cuts; in each iteration the current LP solution is then used to guide a local search heuristic. In addition to standard polyhedral cuts as lifted cover...

  8. Long Period (LP) volcanic earthquake source location at Merapi volcano by using dense array technics

    Science.gov (United States)

    Metaxian, Jean Philippe; Budi Santoso, Agus; Laurin, Antoine; Subandriyo, Subandriyo; Widyoyudo, Wiku; Arshab, Ghofar

    2015-04-01

    Since 2010, Merapi shows unusual activity compared to last decades. Powerful phreatic explosions are observed; some of them are preceded by LP signals. In the literature, LP seismicity is thought to be originated within the fluid, and therefore to be representative of the pressurization state of the volcano plumbing system. Another model suggests that LP events are caused by slow, quasi-brittle, low stress-drop failure driven by transient upper-edifice deformations. Knowledge of the spatial distribution of LP events is fundamental for better understanding the physical processes occurring in the conduit, as well as for the monitoring and the improvement of eruption forecasting. LP events recorded at Merapi have a spectral content dominated by frequencies between 0.8 and 3 Hz. To locate the source of these events, we installed a seismic antenna composed of 4 broadband CMG-6TD Güralp stations. This network has an aperture of 300 m. It is located on the site of Pasarbubar, between 500 and 800 m from the crater rim. Two multi-parameter stations (seismic, tiltmeter, S-P) located in the same area, equipped with broadband CMG-40T Güralp sensors may also be used to complete the data of the antenna. The source of LP events is located by using different approaches. In the first one, we used a method based on the measurement of the time delays between the early beginnings of LP events for each array receiver. The observed differences of time delays obtained for each pair of receivers are compared to theoretical values calculated from the travel times computed between grid nodes, which are positioned in the structure, and each receiver. In a second approach, we estimate the slowness vector by using MUSIC algorithm applied to 3-components data. From the slowness vector, we deduce the back-azimuth and the incident angle, which give an estimation of LP source depth in the conduit. This work is part of the Domerapi project funded by French Agence Nationale de la Recherche (https

  9. Right-sided superior vena cava draining into the left atrium: a rare anomaly of systemic venous return

    International Nuclear Information System (INIS)

    Aminololama-Shakeri, Shadi; Wootton-Gorges, Sandra L.; Reyes, Melissa; Moore, Elizabeth H.; Pretzlaff, Robert K.

    2007-01-01

    The most commonly encountered systemic thoracic venous anomaly is a persistent left superior vena cava that drains into the right atrium via the coronary sinus. A much rarer systemic venous anomaly is that of isolated anomalous drainage of a normally positioned right superior vena cava (RSVC) into the left atrium (LA). This has been reported in approximately 20 patients with the diagnosis usually being made by cardiac catheterization. We report the case of a toddler with asymptomatic hypoxemia resulting from anomalous drainage of a normal RSVC into his LA. This was diagnosed non-invasively by contrast-enhanced chest CT. (orig.)

  10. Tromboembolia pulmonar asociada al síndrome de la vena cava superior de origen trombótico

    Directory of Open Access Journals (Sweden)

    Ana Madeleine Barrera-López

    2017-07-01

    Full Text Available Se describe el caso de un paciente masculino de 32 años de edad, quien consulta al servicio de urgencias con historia clínica del síndrome de la vena cava superior, en el estudio de la angiotomografía pulmonar, se demuestra embolismo pulmonar izquierdo, trombosis de la vena yugular interna derecha y confluente yugulo subclavio. No hay evidencia de asociación con neoplasia, infecciones o enfermedades del tejido conectivo, siendo el único factor de riesgo asociado para la trombosis, hiperviscocidad (tríada de virchow por poliglobulia.

  11. A case of coarctation of the aorta associated with the patent ductus arteriosus and the persistent left superior vena cava

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yoo Keun [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    1974-10-15

    This is a case report of multiple congenital vascular anomalies in which coarctation of the aorta combined with the patent ductus arteriosus and the persistent left superior vena cava. The patient was a 15 year old girl and congenital heart disease was suspected during infancy. However, she heard the disease incurable, so she had been well with herb medicine until admission in our hospital. By physical examination and roentgenological studies including aortography, the diagnosis of the patent ductus arteriosus was detected and the coarctation of the aorta was suspected. The persistent left superior vena cava was found during surgery and it was proved roentgenologically by venography.

  12. Primary Leiomyosarcoma in the Inferior Vena Cava Extended to the Right Atrium: A Case Report and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Shuichi Fujita

    2016-10-01

    Full Text Available A 38-year-old woman had developed an abdominal distention, lower extremity edema, and dyspnea. Imaging examination revealed a large mass in the right atrium which was connected to lesions within the inferior vena cava. Although complete resection of the mass was not possible, partial surgical tumor resection was performed to avoid pulmonary embolization and circulatory collapse. Leiomyosarcoma was diagnosed histologically, and chemotherapy (doxorubicin followed by radiotherapy was started. By reviewing papers published in the past 10 years that included 322 patients, we also discuss the clinical presentations and prognosis of leiomyosarcoma in the inferior vena cava.

  13. Wolff-Parkinson-White syndrome with an unroofed coronary sinus without persistent left superior vena cava treated with catheter cryoablation

    Directory of Open Access Journals (Sweden)

    Andrei Catanchin

    2008-08-01

    Full Text Available Coronary sinus anomalies are rare congenital defects which are usually coexistent with a persistent left superior vena cava and may be associated with cardiac arrhythmias. We report an unroofed coronary sinus without persistent left superior vena cava diagnosed during a catheter ablation procedure for Wolff-Parkinson-White syndrome. Diagnostic and therapeutic options and outcomes are discussed. This condition is of relevance to electrophysiologists performing catheter-based procedures, as well as cardiologists implanting coronary sinus pacing leads, who may encounter this anomaly in their practice.

  14. Abdominal wall phlebitis due to Prevotella bivia following renal transplantation in a patient with an occluded inferior vena cava.

    Science.gov (United States)

    Janssen, S; van Donselaar-van der Pant, K A M I; van der Weerd, N C; Develter, W; Bemelman, F J; Grobusch, M P; Idu, M M; Ten Berge, I J M

    2013-02-01

    Pre-existing occlusion of the inferior vena cava may complicate renal transplantation. Suppurative abdominal wall phlebitis following renal transplantation was diagnosed in a patient with pre-existing thrombosis of the inferior vena cava of unknown cause. The phlebitis developed in the subcutaneous collateral veins of the abdominal wall contra-laterally to the renal transplant. Cultures from abdominal wall micro-abscesses yielded Prevotella bivia as the causative agent. This complication has not been described before in the context of renal transplantation. The pathogenesis and management of this serious complication are discussed in this paper.

  15. Left kidney angiomyolipoma, spreading to the renal vein, inferior vena cava and involving the heart. Report of one case

    OpenAIRE

    INNOCENTI C, FRANCO; ALARCÓN C, EMILIO; ARIAS O, ESTEBAN; STOCKINS L, ALECK; SÁNCHEZ U, ROBERTO; MADARIAGA B, JAIME; TORRES-QUEVEDO Q, RODRIGO; CABRERA E, FELIPE; DÍAZ J, RAMÓN

    2008-01-01

    El angiomiolipoma renal es un tumor benigno mesenquimático. Constituyen sólo del 2 al 6% de los tumores renales. Existen alrededor de 12 casos reportados con invasión a las venas renales y la cava inferior. En menos de 5, hay extensión de trombo tumoral hasta aurícula derecha. Objetivo: Presentar el caso clínico, manejo y evolución de una paciente con un angiomiolipoma renal con extensión tumoral a vena renal y cava inferior y que compromete la cavidad auricular derecha casi en su totalidad. ...

  16. Tromboembolismo pulmonar asociado al síndrome de la vena cava superior de origen trombótico

    OpenAIRE

    Barrera-López, Ana Madeleine; Cortés-P., Luis Arcadio; Salazar-C., Erika María

    2016-01-01

    Se describe el caso de un paciente masculino de 32 años de edad, quien consulta al servicio de urgencias con historia clínica del síndrome de la vena cava superior, en el estudio de la angiotomografía pulmonar, se demuestra embolismo pulmonar izquierdo, trombosis de la vena yugular interna derecha y confluente yugulo subclavio. No hay evidencia de asociación con neoplasia, infecciones o enfermedades del tejido conectivo, siendo el único factor de riesgo asociado para la trombosis, hiperviscoc...

  17. Cavernoma de la vena porta: Descripción de casos clínicos pediátricos

    OpenAIRE

    Maurente, Lucía; García, Ma Lucila; Machado, Karina; López, Carola; Montano, Alicia

    2012-01-01

    Resumen La cavernomatosis portal es una patología poco frecuente causada por la trombosis de la vena porta. Es la principal causa de hipertensión portal en niños. La causa muchas veces no se identifica, pudiendo reconocerse factores predisponentes, entre los cuales los más frecuentes son el cateterismo de la vena umbilical y la onfalitis. Se manifiesta a través de sus complicaciones: hemorragia digestiva alta por várices esofágicas y esplenomegalia. El diagnóstico se confirma con ecografía ab...

  18. Placement of a Retrievable Guenther Tulip Filter in the Superior Vena Cava for Upper Extremity Deep Venous Thrombosis

    International Nuclear Information System (INIS)

    Nadkarni, Sanjay; Macdonald, Sumaira; Cleveland, Trevor J.; Gaines, Peter A.

    2002-01-01

    A retrievable Guenther Tulip caval filter(William Cook, Europe) was successfully placed and retrieved in the superior vena cava for upper extremity deep venous thrombosis in a 56-year-old woman. Bilateral subclavian and internal jugular venous thromboses thought secondary to placement of multiple central venous catheters were present. There have been reports of the use of permanent Greenfield filters and a single case report of a temporary filter in the superior vena cava. As far as we are aware this is the first reported placement and successful retrieval of a filter in these circumstances

  19. Right atrium and superior vena cava pressure measurements in a novel animal model to study one and a half ventricle repair as compared to Fontan type procedure

    Directory of Open Access Journals (Sweden)

    Anil Bhattarai

    2017-01-01

    Full Text Available Background & Objectives: To evaluate the advantages of the one and a half ventricle repair on maintaining a low pressure in the inferior vena cava district. Also evaluate the competition of flows at the superior vena cava – right pulmonary artery anastomosis site, in order to understand the hemodynamic interaction of a pulsatile flow in combination to a laminar one. Materials & Methods: Adult rabbits (n=30 in terminal anaesthesia with a follow up of 8 h were used, randomly distributed in three experimental groups: Group 1: animals with an anastomosis between superior vena cava and right pulmonary artery, as a model of one and one half ventricle repair; Group 2: animals with the cavopulmonary anastomosis followed by clamping of the right pulmonary artery proximal to the anastomosis; and Group 3: sham animals. Pressures of superior vena cava and pulmonary arteries were afterwards measured, in a resting condition as well as after induced pharmacological stress test.Results: In Group 1, superior vena cava pressure was significantly higher, while venous pressure in the inferior vena cava – right atrium district was constant or lower in comparison with the other groups. After stress test, the pressure in the superior vena cava and the heart rate both increased further, but the right ventricular, right atrial and pulmonary artery pressures remained similar to the values in a resting condition. This proved that the inferior vena cava return was well-preserved, and no venous hypertension was present in the inferior vena cava district even after stress test (good exercise tolerance.Conclusion: One and one half ventricle repair can be considered a good surgical strategy for maintaining a low pressure in the inferior vena cava district with potential for right ventricle growth, restoring the more physiological circulation in borderline or failing right ventricle conditions. The experiment presented a positive finding in favour of one and one half

  20. 78 FR 32294 - DeltaPoint Capital IV, L.P., DeltaPoint Capital IV (New York), L.P., License No. 02/02-0662,02/02...

    Science.gov (United States)

    2013-05-29

    ... Small Business Investment Act of 1958, as amended (``the Act''), in connection with the financing of a... SMALL BUSINESS ADMINISTRATION DeltaPoint Capital IV, L.P., DeltaPoint Capital IV (New York), L.P., License No. 02/02-0662,02/02-0661; Notice Seeking Exemption Under Section 312 of the Small Business...

  1. The Methodical Instrumentarium for Analytical Monitoring of Markets for High-Tech Products

    Directory of Open Access Journals (Sweden)

    Mikaelian Suren G.

    2017-10-01

    Full Text Available The article is aimed at clarifying the essential characteristics of high-tech products and specifying the features of analytical monitoring of markets for high-tech products. The conceptual approaches to interpretation of the essence of high-tech products as a basic concept in the categorical apparatus for researching the systemic and complex processes of technological development have been clarified. The most efficient instruments for assessing innovation processes in the high-tech sphere have been systematized. The methodical instrumentarium for analytical monitoring of the markets for high-tech products has been clarified. The terminology of a high-tech product has been clarified in order to formulate the methodical instrumentarium for analytical monitoring of market for high-tech products. It has been determined that «high-tech products» are the original basic concept in the categorical apparatus for researching the systemic and complex processes of the high-tech market that needs to be concretized. Conceptual approaches to the essence of high-tech products have been systematized.

  2. 75 FR 28657 - Dell Products LP-Parmer North Location, a Subsidiary of Dell, Inc., Including On-Site Leased...

    Science.gov (United States)

    2010-05-21

    ... Spherion Corporation; Round Rock, TX; Dell Products LP--Parmer North One; Austin, TX; Amended Certification... Products LP--Parmer North Location, a Subsidiary of Dell, Inc., Including On-Site Leased Workers From... Act of 1974, as amended (``Act''), 19 U.S.C. 2273, the Department of Labor issued a Certification of...

  3. 78 FR 48177 - Purdue Pharma L.P.; Withdrawal of Approval of a New Drug Application for Oxycontin

    Science.gov (United States)

    2013-08-07

    ... DEPARTMENT OF HEALTH AND HUMAN SERVICES Food and Drug Administration [Docket No. FDA-2013-N-0883] Purdue Pharma L.P.; Withdrawal of Approval of a New Drug Application for Oxycontin AGENCY: Food and Drug... Purdue Pharma L.P. (Purdue), One Stamford Forum, Stamford, CT 06901-3431. Purdue has voluntarily...

  4. 75 FR 76037 - HAVI Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of...

    Science.gov (United States)

    2010-12-07

    ... Logistics, North America a Subsidiary of HAVI Group, LP Including On-Site Leased Workers of Express Personnel Services and the La Salle Network, Bloomingdale, IL; Havi Logistics, North America, Lisle, IL..., applicable to workers of HAVI Logistics, North America, a subsidiary of HAVI Group, LP, including on-site...

  5. 78 FR 48205 - Ranger Alternative Management, L.P. and Ranger Funds Investment Trust; Notice of Application

    Science.gov (United States)

    2013-08-07

    ... Alternative Management, L.P. and Ranger Funds Investment Trust; Notice of Application August 1, 2013. AGENCY... Management, L.P. (``Ranger'') and Ranger Funds Investment Trust (the ``Trust''). Summary of Application... (e) certain registered management investment companies and unit investment trusts outside of the same...

  6. The antimicrobial lysine-peptoid hybrid LP5 inhibits DNA replication and induces the SOS response in Staphylococcus aureus

    DEFF Research Database (Denmark)

    Gottschalk, Sanne; Ifrah, Dan; Lerche, Sandra

    2013-01-01

    the growth of S. aureus without ATP leakage. Instead, LP5 bound DNA and inhibited macromolecular synthesis. The binding to DNA also led to inhibition of DNA gyrase and topoisomerase IV and caused induction of the SOS response. CONCLUSIONS: Our data demonstrate that LP5 may have a dual mode of action against...

  7. Prenatal exposure to a maternal LP diet decreases BDNF expression in the brains of the neonatal offspring

    Science.gov (United States)

    Maternal low protein (LP) diets during gestation cause learning and mernmy impai1ment as well as cognitive deficits in the neonatal and adult offsp1ing. The cellular and molecular mechanism that mediate the deleterious effects of prenatal exposure to a maternal LP diet on cognitive function is egreg...

  8. 76 FR 2432 - Bancshares Capital, L.P.; Notice of Surrender Under 13 CFR 107.1900

    Science.gov (United States)

    2011-01-13

    ... SMALL BUSINESS ADMINISTRATION [License No. 10/10-0194] Bancshares Capital, L.P.; Notice of Surrender Under 13 CFR 107.1900 Pursuant to the authority granted to the United States Small Business... 107.1900 of the Small Business Administration Rules and Regulations Bancshares Capital, L.P., 16118...

  9. 75 FR 79065 - Emergence Capital Partners SBIC, L.P. License No. 09/79-0454; Notice Seeking Exemption Under...

    Science.gov (United States)

    2010-12-17

    ... 95113. The financing is contemplated for working capital and general operating purposes. The financing... SMALL BUSINESS ADMINISTRATION Emergence Capital Partners SBIC, L.P. License No. 09/79-0454; Notice... hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo, CA 94402...

  10. 77 FR 20871 - Praesidian Capital Opportunity Fund III, LP; License No. 02/02-0647; Notice Seeking Exemption...

    Science.gov (United States)

    2012-04-06

    ... contemplated to fund working capital and capital expenditures. The financing is brought within the purview of... SMALL BUSINESS ADMINISTRATION Praesidian Capital Opportunity Fund III, LP; License No. 02/02- 0647... given that Praesidian Capital Opportunity Fund III, LP, 419 Park Avenue South, New York, NY 10016, a...

  11. 75 FR 39588 - Emergence Capital Partners SBIC, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2010-07-09

    ..., San Jose, California 95113. The financing is contemplated for working capital and general operating... SMALL BUSINESS ADMINISTRATION [License No. 09/79-0454] Emergence Capital Partners SBIC, L.P... Notice is hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo...

  12. 76 FR 76474 - Emergence Capital Partners SBIC, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2011-12-07

    ..., Emeryville, CA 94608 (``Lithium''). The financing is contemplated for working capital and general operating... SMALL BUSINESS ADMINISTRATION [License No. 09/79-0454] Emergence Capital Partners SBIC, L.P... Notice is hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo...

  13. 75 FR 32230 - Solutions Capital I, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business...

    Science.gov (United States)

    2010-06-07

    ... working capital and general corporate purposes. The financing is brought within the purview of Sec. 107... SMALL BUSINESS ADMINISTRATION [License No. 03/03-0247] Solutions Capital I, L.P.; Notice Seeking... given that Solutions Capital I, L.P., 1100 Wilson Blvd., Suite 3000, Arlington, VA 22209, a Federal...

  14. 76 FR 1491 - Emergence Capital Partners SBIC, L.P. License No. 09/79-0454; Notice Seeking Exemption Under...

    Science.gov (United States)

    2011-01-10

    ... financing is contemplated for working capital and general operating purposes. The financing is brought... SMALL BUSINESS ADMINISTRATION Emergence Capital Partners SBIC, L.P. License No. 09/79-0454; Notice... hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo, CA 94402...

  15. 76 FR 28843 - Emergence Capital Partners SBIC, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2011-05-18

    ... 94404. The financing is contemplated for working capital and general operating purposes. The financing... SMALL BUSINESS ADMINISTRATION [License No. 09/79-0454] Emergence Capital Partners SBIC, L.P... Notice is hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo...

  16. 75 FR 32230 - Emergence Capital Partners SBIC, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2010-06-07

    ... is contemplated for working capital and general operating purposes. The financing is brought within... SMALL BUSINESS ADMINISTRATION [License No. 09/79-0454] Emergence Capital Partners SBIC, L.P... Notice is hereby given that Emergence Capital Partners SBIC, L.P., 160 Bovet Road, Suite 300, San Mateo...

  17. 76 FR 68803 - Escalate Capital Partners SBIC I, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2011-11-07

    ... Courtyard Drive, Suite 309, Austin, TX 78730. The financing is contemplated to provide working capital and... SMALL BUSINESS ADMINISTRATION [License No. 06/06-0335] Escalate Capital Partners SBIC I, L.P... Notice is hereby given that Escalate Capital Partners, SBIC I, L.P., 300 W. 6th Street, Suite 2250...

  18. 76 FR 36910 - Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas...

    Science.gov (United States)

    2011-06-23

    ... Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC... Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power [[Page... subscribed docket(s). For assistance with any FERC Online service, please e-mail [email protected

  19. 76 FR 34692 - Astoria Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas...

    Science.gov (United States)

    2011-06-14

    ... Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC... Generating Company, L.P., NRG Power Marketing LLC, Arthur Kill Power LLC, Astoria Gas Turbine Power LLC... notification when a document is added to a subscribed docket(s). For assistance with any FERC Online service...

  20. 78 FR 4842 - Linden VFT, LLC v. Brookfield Energy Marketing, LP, Cargill Power Markets, LLC; Notice of Complaint

    Science.gov (United States)

    2013-01-23

    ... v. Brookfield Energy Marketing, LP, Cargill Power Markets, LLC; Notice of Complaint Take notice that... Brookfield Energy Marketing, LP and Cargill Power Markets, LLC (Respondents) alleging that, Respondents... subscribed docket(s). For assistance with any FERC Online service, please email [email protected

  1. 78 FR 338 - Buckeye Hammond Railroad, L.L.C.; Acquisition and Operation Exemption; Buckeye Partners, L.P.

    Science.gov (United States)

    2013-01-03

    ... Railroad, L.L.C.; Acquisition and Operation Exemption; Buckeye Partners, L.P. Buckeye Hammond Railroad, L.L... acquire from Buckeye Partners, L.P., a noncarrier, and to operate approximately 6,797 feet (1.29 miles) of...: December 26, 2012. By the Board, Rachel D. Campbell, Director, Office of Proceedings. Jeffrey Herzig...

  2. 77 FR 71680 - Buckeye East Chicago Railroad, LLC-Acquisition and Operation Exemption-Buckeye Partners, L.P.

    Science.gov (United States)

    2012-12-03

    ... Chicago Railroad, LLC--Acquisition and Operation Exemption--Buckeye Partners, L.P. Buckeye East Chicago... acquire from Buckeye Partners, L.P., a noncarrier, and to operate approximately 7,065 feet (1.34 miles) of..., 2012. By the Board, Rachel D. Campbell, Director, Office of Proceedings. Jeffrey Herzig, Clearance Unit...

  3. 78 FR 78350 - Houston Pipe Line Company, LP; Notice of Intent to Prepare an Environmental Assessment for the...

    Science.gov (United States)

    2013-12-26

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP14-13-000] Houston Pipe Line Company, LP; Notice of Intent to Prepare an Environmental Assessment for the Proposed 24-Inch... Hidalgo County, Texas by Houston Pipe Line Company, LP (HPL). The Commission will use this EA in its...

  4. 75 FR 6414 - Cardinal Growth, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business...

    Science.gov (United States)

    2010-02-09

    ... SMALL BUSINESS ADMINISTRATION [License No. 05/75-0257] Cardinal Growth, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business Investment Act, Conflicts of Interest Notice is hereby given that Cardinal Growth, L.P., 311 South Wacker Driver, Suite 5500, Chicago, IL 60606, a Federal...

  5. 78 FR 77770 - Ironwood Equity Fund, LP; Notice Seeking Exemption Under Section 312 of the Small Business...

    Science.gov (United States)

    2013-12-24

    ... proposes to Finance a small business in which its Associate Ironwood Mezzanine Fund II, LP has an equity... SMALL BUSINESS ADMINISTRATION [ License No. 01171-0406] Ironwood Equity Fund, LP; Notice Seeking Exemption Under Section 312 of the Small Business Investment Act, Conflicts of Interest Notice is hereby...

  6. 77 FR 42353 - Escalate Capital Partners SBIC I, L.P.; Notice Seeking Exemption Under Section 312 of the Small...

    Science.gov (United States)

    2012-07-18

    ... Regulations because Escalate Capital Partners SBIC I, L.P. proposes to Finance a small business in which its... SMALL BUSINESS ADMINISTRATION [License No. 06/06-0335] Escalate Capital Partners SBIC I, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business Investment Act, Conflicts of Interest...

  7. 76 FR 66710 - Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing, Soliciting Comments...

    Science.gov (United States)

    2011-10-27

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 5984-063] Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing, Soliciting Comments, Motions To Intervene, and....: 5984-063. c. Date Filed: May 10, 2011. d. Applicant: Erie Boulevard Hydropower, L.P. (dba Brookfield...

  8. 78 FR 68044 - Erie Boulevard Hydropower, L.P.; Notice of Scoping Meetings and Environmental Site Review and...

    Science.gov (United States)

    2013-11-13

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 7320-042] Erie Boulevard Hydropower, L.P.; Notice of Scoping Meetings and Environmental Site Review and Soliciting Scoping Comments.... Date filed: July 1, 2013. d. Applicant: Erie Boulevard Hydropower, L.P. e. Name of Project: Chasm...

  9. 78 FR 62348 - Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing and Soliciting Motions...

    Science.gov (United States)

    2013-10-18

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 7320-042] Erie Boulevard Hydropower, L.P.; Notice of Application Accepted for Filing and Soliciting Motions To Intervene and Protests.... Date filed: July 1, 2013. d. Applicant: Erie Boulevard Hydropower, L.P. e. Name of Project: Chasm...

  10. 77 FR 11618 - Solutions Capital I, L.P.; Notice Seeking Exemption Under the Small Business Investment Act...

    Science.gov (United States)

    2012-02-27

    ... SMALL BUSINESS ADMINISTRATION [License No. 03/03-0247] Solutions Capital I, L.P.; Notice Seeking Exemption Under the Small Business Investment Act, Conflicts of Interest Notice is hereby given that Solutions Capital I, L.P., 1100 Wilson Blvd., Suite 3000, Arlington, VA 22209, a Federal Licensee under the...

  11. 75 FR 3502 - KLH Capital, L.P.; Notice Seeking Exemption Under 312 of the Small Business Investment Act...

    Science.gov (United States)

    2010-01-21

    ... SMALL BUSINESS ADMINISTRATION [License No. 04/04-0296] KLH Capital, L.P.; Notice Seeking Exemption Under 312 of the Small Business Investment Act, Conflicts of Interest Notice is hereby given that KLH Capital, L.P., 101 East Kennedy Boulevard, Suite 3925, Tampa, Florida 33602, a Federal Licensee under the...

  12. 76 FR 17180 - KLH Capital II, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business Investment...

    Science.gov (United States)

    2011-03-28

    ... SMALL BUSINESS ADMINISTRATION [License No. 04/04-0296] KLH Capital II, L.P.; Notice Seeking Exemption Under Section 312 of the Small Business Investment Act, Conflicts of Interest Notice is hereby given that KLH Capital, L.P., 101 East Kennedy Boulevard, Suite 3925, Tampa, FL, 33602 a Federal...

  13. Entrepreneurship in high-tech and knowledge-intensive sectors

    DEFF Research Database (Denmark)

    Christensen, Patrizia V.; Madsen, Henning; Neergaard, Helle

    development of new enterprises in high-tech and knowledge-intensive sectors are analysed in relation to the educational and professional background of the entrepreneur/entrepreneurial team, as well as the personal and professional social networks of the entrepreneurs. The analysis is based on a theoretical...... framework combining theories of human and social capital. Secondary aspects addressed in the research project are questions of male vs. female entrepreneurship, internationalisation-globalisation, and business success/failure.......The paper investigates key factors influencing the establishment and early growth of high-tech and knowledge-intensive new firms in Denmark. Particular attention is paid to the human and social variables affecting the creation, survival, and growth of such firms. The establishment and subsequent...

  14. The clinical implications of variants of vena cava inferior and aorta on retroperitoneal surgery

    Directory of Open Access Journals (Sweden)

    S. V. Mukhtarulina

    2014-12-01

    Full Text Available Objective: to study variants of retroperitoneal vascular structure and its clinical implications on retroperitoneal surgery in patients with cervical cancer IA–IIB stage.Materials and methods. 101 patients who underwent paraaortic and bilateral pelvic lymphadenectomy were included in this study. 10 patients of the first group with anomalies of inferior vena cava, renal arteries and veins, common iliac vein and ovarian vessels were compared with 91 patients of the second group without anomalies.Results. Variants of major retroperitoneal vascular structure were present in 10 (9.9 % patients. Supernumerary renal arteries and veins observed in 5 (4.9 % patients; retroaortic left renal vein type I and II – in 3 (3.0 % patients. Double vena cava inferior detected in 1 (1.0 % patient. Patients with variants of retroperitoneal vascular structures hadn’t vessel injury. There was no difference in intraoperative hemorrhage, transfusion red blood cell, rate of intraoperative hemoglobin and removed paraaortic lymph nodes between the groups. Risk factors for intraoperative bleeding in patients with cervical cancer, depending on the presence or absence of anomalies of retroperitoneal vessels had no significant difference.Conclusion. Despite the fact that the variants of retroperitoneal vascular structures are rare (9.9 %, the success of retroperitoneal surgery is associated with the knowledge of vascular variations which decrease serious, life-threatening complications.

  15. Nursing care of the complications caused by vena cava filter placement and thrombolytic therapy

    International Nuclear Information System (INIS)

    Ma Congfeng; Tan Meifang; Fu Bing; Luo Chunhua; Jiang Fengjiao

    2011-01-01

    Objective: To discuss the nursing care and observation measures for the complications occurred after vena cava filter placement and thrombolytic therapy. Methods: During the period of July 2007-March 2010, vena cava filter placement and thrombolytic therapy were employed in 70 patients. The observation for the main procedure-related complications was made. The main complications included bleeding tendency, pulmonary embolism, filter migration or loss, thrombus formation within filter, IVC perforation due to filter, venous insufficiency and skin blisters of the affected lower extremity. Results: The total effective rate of thrombolytic treatment in 70 patients was 95.7%. As reasonable and effective nursing care measures were implemented, no major complications, such as pulmonary embolism, filter migration or loss,thrombus formation within filter, IVC perforation due to filter, infection, etc. occurred. The other complications developed in some patients,which included hematuria (n=4), bleeding at puncturing site (n=3), bleeding at abdominal incision (n=3), subcutaneous ecchymosis (n=3) and skin vesicles of diseased limb (n=3), all of which were cured after proper management. Conclusion: Postoperative nursing is a kind of prospective nursing care, the primary purpose of which is to prevent the occurrence of the potential complications after surgery. Therefore, solid fundamental knowledge, careful observation ability and strong consciousness of responsibility are most important.(authors)

  16. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Fagedet, Dorothee, E-mail: DFagedet@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de medecine interne, Pole Pluridisciplinaire de Medecine (France); Thony, Frederic, E-mail: FThony@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Timsit, Jean-Francois, E-mail: JFTimsit@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de reanimation, Pole Medecine Aiguee Communautaire (France); Rodiere, Mathieu, E-mail: MRodiere@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Monnin-Bares, Valerie, E-mail: v-monnin@chu-montpellier.fr [CHRU Arnaud de Villeneuve, Imagerie Medicale Thoracique Cardiovasculaire (France); Ferretti, Gilbert R., E-mail: GFerretti@chu-grenoble.fr [CHU de Grenoble, Clinique universitaire de radiologie et imagerie medicale, Pole d' Imagerie (France); Vesin, Aurelien; Moro-Sibilot, Denis, E-mail: DMoro.pneumo@chu-grenoble.fr [University Grenoble 1 e Albert Bonniot Institute, Inserm U823 (France)

    2013-02-15

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  17. Is it worth adding an inferior vena cava filter to anticoagulation in thromboembolic disease?

    Directory of Open Access Journals (Sweden)

    Alexandra Yunes

    2017-06-01

    Full Text Available Resumen A pesar del tratamiento anticoagulante, algunos pacientes que han presentado un episodio de enfermedad tromboembólica persisten con riesgo elevado de recurrencia. Se ha planteado que adicionar un filtro de vena cava inferior podría disminuir este riesgo, pero la real utilidad clínica no está clara. Para responder esta pregunta utilizamos la base de datos Epistemonikos, la cual es mantenida mediante búsquedas en múltiples fuentes de información. Identificamos tres revisiones sistemáticas que en conjunto incluyen cuatro ensayos aleatorizados que responden la pregunta. Extrajimos los datos, realizamos un metanálisis y preparamos tablas de resumen de los resultados utilizando el método GRADE. Concluimos que podría existir poca o nula diferencia en cuanto a la ocurrencia de trombosis venosa profunda al agregar un filtro de vena cava inferior en pacientes anticoagulados, y que no está claro si existen diferencias en cuanto a la ocurrencia de tromboembolismo pulmonar o mortalidad porque la certeza de la evidencia es muy baja.

  18. Endovascular Treatment of Malignant Superior Vena Cava Syndrome: Results and Predictive Factors of Clinical Efficacy

    International Nuclear Information System (INIS)

    Fagedet, Dorothée; Thony, Frederic; Timsit, Jean-François; Rodiere, Mathieu; Monnin-Bares, Valérie; Ferretti, Gilbert R.; Vesin, Aurélien; Moro-Sibilot, Denis

    2013-01-01

    To demonstrate the effectiveness of endovascular treatment (EVT) with self-expandable bare stents for malignant superior vena cava syndrome (SVCS) and to analyze predictive factors of EVT efficacy. Retrospective review of the 164 patients with malignant SVCS treated with EVT in our hospital from August 1992 to December 2007 and followed until February 2009. Endovascular treatment includes angioplasty before and after stent placement. We used self-expandable bare stents. We studied results of this treatment and looked for predictive factors of clinical efficacy, recurrence, and complications by statistical analysis. Endovascular treatment was clinically successful in 95% of cases, with an acceptable rate of early mortality (2.4%). Thrombosis of the superior vena cava was the only independent factor for EVT failure. The use of stents over 16 mm in diameter was a predictive factor for complications (P = 0.008). Twenty-one complications (12.8%) occurred during the follow-up period. Relapse occurred in 36 patients (21.9%), with effective restenting in 75% of cases. Recurrence of SVCS was significantly increased in cases of occlusion (P = 0.01), initial associated thrombosis (P = 0.006), or use of steel stents (P = 0.004). Long-term anticoagulant therapy did not influence the risk of recurrence or complications. In malignancy, EVT with self-expandable bare stents is an effective SVCS therapy. These results prompt us to propose treatment with stents earlier in the clinical course of patients with SVCS and to avoid dilatation greater than 16 mm.

  19. Interorganizational imitation and acquisitions of high-tech ventures

    OpenAIRE

    Ozmel, Umit; Reuer, J. J.; Wu, Cheng-Wei

    2017-01-01

    Research summary: This article shows that there is a positive association between the changes in the number of prior acquisitions or the changes in the prominence of prior acquirers within the focal venture's subfield and the venture's likelihood to be acquired. Results are in line with the existence of frequency- and trait-based imitation in acquisitions targeting tech ventures. More importantly, these positive associations are more pronounced when (a) exogenous technological uncertainty wit...

  20. Orientace na konkurenci u hi-tech podniků

    Directory of Open Access Journals (Sweden)

    Lucie Kaňovská

    2013-10-01

    Full Text Available Purpose: The purpose of this paper is to examine the connection between market orientation and mainly competitor orientation and business performance at the hi-tech companies in the Czech Republic. Design/methodology/approach: The paper involves the New Method for measuring of market orientation. Data are collected through the survey and were used for the data analysis. Findings: The paper involves new aspects for perceiving competitor orientation, as a part of market orientation, and business performance. The result concurs with the results of researches of market orientation realized at this branch. Results show that competitor orientation has significant influence on business performance. Research limitations implications: The limitations are based on the methodology used for gaining data. However, the overall response rate is almost 20 %. The hi-tech industry is fast changing. From this reason, there can be many changes and it is impossible to repeat the research at the same companies. Practical implications: Our findings can help to understand market orientation and its relationship to competitors and business performance. Managers can use method for measuring of market orientation and can find out the level of market orientation at their companies. They can compare their results with the published average results of hi-tech companies. Originality/value: The originality of the paper comes from combining market orientation, the view of competition and business performance at hi-tech companies. The measurement of market orientation was made through the New Method. The model of the New method was constructed along after analysis of other 25 methods; we tried to eliminate the failings criticized in other methods.

  1. Orientace na konkurenci u hi-tech podniků

    OpenAIRE

    Kaňovská, Lucie; Tomášková, Eva

    2012-01-01

    Purpose: The purpose of this paper is to examine the connection between market orientation and mainly competitor orientation and business performance at the hi-tech companies in the Czech Republic. Design/methodology/approach: The paper involves the New Method for measuring of market orientation. Data are collected through the survey and were used for the data analysis. Findings: The paper involves new aspects for perceiving competitor orientation, as a part of market orientation, and busines...

  2. Virginia Tech recognizes National Farm Safety and Health Week

    OpenAIRE

    Sutphin, Michael D.

    2006-01-01

    Virginia Tech's College of Agriculture and Life Sciences and Virginia Cooperative Extension are observing National Farm Safety and Health Week, Sept. 18-22. This week commemorates the hard work, diligence, and sacrifices of our nation's farmers and ranchers and dovetails the announcement of an $800,000 grant to improve the lives of Virginia's farmers, their families, and those who live in rural communities.

  3. Lesbians and tech: Analyzing digital media technologies and lesbian experience.

    Science.gov (United States)

    Harris, Angelique; Daniels, Jessie

    2017-11-28

    The rise of the popular Internet has coincided with the increasing acceptance, even assimilation, of lesbians into mainstream society. The visible presence of lesbians in the tech industry and in digitally mediated spaces raises a set of questions about the relationship between queer identities and Internet technologies. This introduction to a special issue of Journal of Lesbian Studies explores some of these questions and provides an overview of the articles that follow.

  4. Finnish High Tech in China - A Study of Business Culture

    OpenAIRE

    Suhonen, Petri

    2013-01-01

    The objective of this thesis was to study the challenges caused by differences in Finnish and Chinese business cultures in the high technology industry. The study explains the main characteristics of the Chinese national and business cultures which every company operating in China will be dealing with, and offers examples of how these affect a high tech company. The study was conducted as a case study of a Finnish high technology company running a project in China. The company encountere...

  5. PROCESS MANAGEMENT IN HIGH TECH NEW ZEALAND FIRMS

    OpenAIRE

    LINCOLN WOOD; QIANG LU

    2008-01-01

    There are three distinct functions in the product realization chain — product design, process design, and process execution; thus there are two interfaces (product design — process design; process design — process execution) rather than one (product-manufacturing). Case studies of four organizations manufacturing high-tech products in New Zealand are explored to study the organization of process design functions and success strategies. Similarities in structuring, relationships between functi...

  6. FUNDAMENTALIZATION OF ICT LEARNING IN MODERN HIGH TECH ENVIRONMENT

    Directory of Open Access Journals (Sweden)

    M. P. Shyshkina

    2013-03-01

    Full Text Available The article outlines the features of the process of fundamentalization of ICT learning, educational background to ensure it in high school. The concept of fundamental knowledge and its role in training of a specialist is described. The problems of access to qualitative education, particularly to electronic learning resources in modern high-tech environment are revealed. The role of computer mathematics as a tool of ICT learning fundamentalization is emphasized.

  7. Virginia Tech Wildlife Student Studies Cheetah Home Ranges

    OpenAIRE

    Davis, Lynn

    2003-01-01

    The cheetah may be the world's fastest land animal, accelerating to high speeds in just a few steps, but within recent years the cheetahs of South Africa are battling the race for survival. To find remedies for this problem Peter Laver, a graduate student in fisheries and wildlife sciences in the College of Natural Resources at Virginia Tech, is expanding current research on home ranges of the cheetah population located in the Serengeti National Park in Tanzania, Africa.

  8. Capturing the real value in high-tech acquisitions.

    Science.gov (United States)

    Chaudhuri, S; Tabrizi, B

    1999-01-01

    Eager to stay ahead of fast-changing markets, more and more high-tech companies are going outside for competitive advantage. Last year in the United States alone, there were 5,000 high-tech acquisitions, but many of them yielded disappointing results. The reason, the authors contend, is that most managers have a shortsighted view of strategic acquisitions--they focus on the specific products or market share. That focus might make sense in some industries, where those assets can confer substantial advantages, but in high tech, full-fledged technological capabilities--tied to skilled people--are the key to long-term success. Instead of simply following the "buzz," successful acquires systematically assess their own capability needs. They create product road maps to identify holes in their product line. While the business group determines if it can do the work in-house, the business development office scouts for opportunities to buy it. Once business development locates a candidate, it conducts an expanded due diligence, which goes beyond strategic, financial, and legal checks. Successful acquires are focused on long-term capabilities, so they make sure that the target's products reflect a real expertise. They also look to see if key people would be comfortable in the new environment and if they have incentives to stay on board. The final stage of a successful acquisition focuses on retaining the new people--making sure their transition goes smoothly and their energies stay focused. Acquisitions can cause great uncertainty, and skilled people can always go elsewhere. In short, the authors argue, high-tech acquisitions need a new orientation around people, not products.

  9. A new LP formulation of the admission control problem modelled as an MDP under average reward criterion

    Science.gov (United States)

    Pietrabissa, Antonio

    2011-12-01

    The admission control problem can be modelled as a Markov decision process (MDP) under the average cost criterion and formulated as a linear programming (LP) problem. The LP formulation is attractive in the present and future communication networks, which support an increasing number of classes of service, since it can be used to explicitly control class-level requirements, such as class blocking probabilities. On the other hand, the LP formulation suffers from scalability problems as the number C of classes increases. This article proposes a new LP formulation, which, even if it does not introduce any approximation, is much more scalable: the problem size reduction with respect to the standard LP formulation is O((C + 1)2/2 C ). Theoretical and numerical simulation results prove the effectiveness of the proposed approach.

  10. 65 nm LP/GP mix low cost platform for multi-media wireless and consumer applications

    Science.gov (United States)

    Tavel, B.; Duriez, B.; Gwoziecki, R.; Basso, M. T.; Julien, C.; Ortolland, C.; Laplanche, Y.; Fox, R.; Sabouret, E.; Detcheverry, C.; Boeuf, F.; Morin, P.; Barge, D.; Bidaud, M.; Biénacel, J.; Garnier, P.; Cooper, K.; Chapon, J. D.; Trouiller, Y.; Belledent, J.; Broekaart, M.; Gouraud, P.; Denais, M.; Huard, V.; Rochereau, K.; Difrenza, R.; Planes, N.; Marin, M.; Boret, S.; Gloria, D.; Vanbergue, S.; Abramowitz, P.; Vishnubhotla, L.; Reber, D.; Stolk, P.; Woo, M.; Arnaud, F.

    2006-04-01

    A complete 65 nm CMOS platform, called LP/GP Mix, has been developed employing thick oxide transistor (IO), Low Power (LP) and General Purpose (GP) devices on the same chip. Dedicated to wireless multi-media and consumer applications, this new triple gate oxide platform is low cost (+1mask only) and saves over 35% of dynamic power with the use of the low operating voltage GP. The LP/GP mix shows competitive digital performance with a ring oscillator (FO = 1) speed equal to 7 ps per stage (GP) and 6T-SRAM static power lower than 10 pA/cell (LP). Compatible with mixed-signal design requirements, transistors show high voltage gain, low mismatch factor and low flicker noise. Moreover, to address mobile phone demands, excellent RF performance has been achieved with FT = 160 GHz for LP and 280 GHz for GP nMOS transistors.

  11. 78 FR 17389 - Texas Eastern Transmission, LP; Notice of Application for Certificate of Public Convenience and...

    Science.gov (United States)

    2013-03-21

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket Nos. CP13-84-000; PF12-19-000] Texas Eastern Transmission, LP; Notice of Application for Certificate of Public Convenience and Necessity and Authorization for Abandonment Take notice that on February 27, 2013, Texas Eastern...

  12. 76 FR 70438 - Enterprise Intrastate L.P., Enterprise Texas Pipeline LLC; Notice of Filing

    Science.gov (United States)

    2011-11-14

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR12-4-000; Docket No. PR12-5-000; Not Consolidated] Enterprise Intrastate L.P., Enterprise Texas Pipeline LLC; Notice of Filing Take notice that on November 1, 2011, the applicants listed above filed a revised Statement of...

  13. 75 FR 65467 - Enterprise Alabama Intrastate, LLC; Enterprise Intrastate L.P; Notice of Baseline Filings

    Science.gov (United States)

    2010-10-25

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. PR11-4-000; Docket No. PR11-5-000; Not Consolidated] Enterprise Alabama Intrastate, LLC; Enterprise Intrastate L.P; Notice of Baseline Filings October 18, 2010. Take notice that on October 15, 2010, the applicants listed above...

  14. Serum Lp-PLA2: as a novel viewpoint in periodontal treatment of hyperlipidaemics.

    Science.gov (United States)

    Fentoğlu, Özlem; Kirzioğlu, Fatma Yeşim; Tözüm Bulut, Memduha; Kurgan, Şivge; Koçak, Havva; Sütcü, Recep; Kale Köroğlu, Banu; Günhan, Meral

    2015-01-01

    To evaluate the effects of periodontal treatment on serum lipoprotein-associated phospholipase A2 (Lp-PLA2) and C-reactive protein (CRP) levels in hyperlipidaemic patients with periodontitis. The study included 52 hyperlipidaemics and 28 systemically healthy controls (C) with periodontitis. Of the 52 hyperlipidaemics, 29 received a suggested diet (HD), and 23 of them were prescribed statin (HS). Clinical periodontal parameters, serum lipids, Lp-PLA2, and CRP levels were assessed at the baseline and 2 months after the completion of the nonsurgical periodontal treatment (2MPT). Serum parameters were also evaluated 1 week following the periodontal treatment (1WPT). At the baseline, patients in the HS group had a higher percentage of bleeding on probing than those in the C and HD groups. Hyperlipidaemics had higher serum triglyceride levels than the control group at 2MPT compared to the baseline. At 2MPT, the levels of Lp-PLA2 in the HS group were significantly higher compared to the baseline and 1WPT. There were no statistically significant differences in CRP levels between study periods for all groups. The periodontal treatment may affect the inflammatory control of hyperlipidaemic patients with periodontitis via increased Lp-PLA2 levels and severity of the impaired lipid metabolism. These findings may be important regarding the therapeutic strategies for hyperlipidaemics with periodontitis.

  15. State of the Art in LP-WAN Solutions for Industrial IoT Services

    Directory of Open Access Journals (Sweden)

    Ramon Sanchez-Iborra

    2016-05-01

    Full Text Available The emergence of low-cost connected devices is enabling a new wave of sensorization services. These services can be highly leveraged in industrial applications. However, the technologies employed so far for managing this kind of system do not fully cover the strict requirements of industrial networks, especially those regarding energy efficiency. In this article a novel paradigm, called Low-Power Wide Area Networking (LP-WAN, is explored. By means of a cellular-type architecture, LP-WAN–based solutions aim at fulfilling the reliability and efficiency challenges posed by long-term industrial networks. Thus, the most prominent LP-WAN solutions are reviewed, identifying and discussing the pros and cons of each of them. The focus is also on examining the current deployment state of these platforms in Spain. Although LP-WAN systems are at early stages of development, they represent a promising alternative for boosting future industrial IIoT (Industrial Internet of Things networks and services.

  16. 77 FR 73089 - Cambria Investment Management, L.P. and Cambria ETF Trust; Notice of Application

    Science.gov (United States)

    2012-12-07

    ... Investment Management, L.P. and Cambria ETF Trust; Notice of Application November 30, 2012. AGENCY... (e) certain registered management investment companies and unit investment trusts outside of the same... Jennifer L. Sawin, Branch Chief, at (202) 551-6821 (Division of Investment Management, Office of Investment...

  17. 77 FR 74884 - Cambria Investment Management, L.P. and Cambria ETF Trust; Notice of Application

    Science.gov (United States)

    2012-12-18

    ... Investment Management, L.P. and Cambria ETF Trust; Notice of Application December 12, 2012. AGENCY... request an order that permits: (a) Actively-managed series of certain open-end management investment... registered management investment companies and unit investment trusts outside of the same group of investment...

  18. Efficacy and safety of the probiotic Lactobacillus paracasei LP-33 in allergic rhinitis

    DEFF Research Database (Denmark)

    Costa, D J; Marteau, P; Amouyal, M

    2014-01-01

    BACKGROUND/OBJECTIVES: An imbalance between Th1 and Th2 cells is involved in allergic rhinitis (AR) that may be improved by probiotics. To test the efficacy of the probiotic Lactobacillus paracasei subsp. paracasei LP-33, a double-blind, placebo-controlled, randomized trial was carried out in pat...

  19. 76 FR 63918 - Tesoro Refining and Marketing Company v. SFPP, L.P.; Notice of Complaint

    Science.gov (United States)

    2011-10-14

    ... and Marketing Company v. SFPP, L.P.; Notice of Complaint Take notice that on October 5, 2011, pursuant... section 1(13) of the Interstate Commerce Act (ICA), 49 U.S.C. App. 13(1), Tesoro Refining and Marketing... document is added to a subscribed docket(s). For assistance with any FERC Online service, please e-mail...

  20. 76 FR 71014 - Idaho Power Company, IDACORP Energy, L.P., IDACORP, Inc.; Notice of Petition

    Science.gov (United States)

    2011-11-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. IN03-9-000] Idaho Power Company, IDACORP Energy, L.P., IDACORP, Inc.; Notice of Petition Take notice that on September 9, 2011..., 2003,\\1\\ filed a petition to terminate Appendix B, Appendix C, and Appendix E to the Settlement...

  1. Study on the mechanism and efficiency of simulated annealing using an LP optimization benchmark problem - 113

    International Nuclear Information System (INIS)

    Qianqian, Li; Xiaofeng, Jiang; Shaohong, Zhang

    2010-01-01

    Simulated Annealing Algorithm (SAA) for solving combinatorial optimization problems is a popular method for loading pattern optimization. The main purpose of this paper is to understand the underlying search mechanism of SAA and to study its efficiency. In this study, a general SAA that employs random pair exchange of fuel assemblies to search for the optimum fuel Loading Pattern (LP) is applied to an exhaustively searched LP optimization benchmark problem. All the possible LPs of the benchmark problem have been enumerated and evaluated via the use of the very fast and accurate Hybrid Harmonics and Linear Perturbation (HHLP) method, such that the mechanism of SA for LP optimization can be explicitly analyzed and its search efficiency evaluated. The generic core geometry itself dictates that only a small number LPs can be generated by performing random single pair exchanges and that the LPs are necessarily mostly similar to the initial LP. This phase space effect turns out to be the basic mechanism in SAA that can explain its efficiency and good local search ability. A measure of search efficiency is introduced which shows that the stochastic nature of SAA greatly influences the variability of its search efficiency. It is also found that using fuel assembly k-infinity distribution as a technique to filter the LPs can significantly enhance the SAA search efficiency. (authors)

  2. State of the Art in LP-WAN Solutions for Industrial IoT Services.

    Science.gov (United States)

    Sanchez-Iborra, Ramon; Cano, Maria-Dolores

    2016-05-17

    The emergence of low-cost connected devices is enabling a new wave of sensorization services. These services can be highly leveraged in industrial applications. However, the technologies employed so far for managing this kind of system do not fully cover the strict requirements of industrial networks, especially those regarding energy efficiency. In this article a novel paradigm, called Low-Power Wide Area Networking (LP-WAN), is explored. By means of a cellular-type architecture, LP-WAN-based solutions aim at fulfilling the reliability and efficiency challenges posed by long-term industrial networks. Thus, the most prominent LP-WAN solutions are reviewed, identifying and discussing the pros and cons of each of them. The focus is also on examining the current deployment state of these platforms in Spain. Although LP-WAN systems are at early stages of development, they represent a promising alternative for boosting future industrial IIoT (Industrial Internet of Things) networks and services.

  3. 75 FR 6200 - Equitrans, L.P.; Notice of Request Under Blanket Authorization

    Science.gov (United States)

    2010-02-08

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP10-46-000] Equitrans, L.P..., Monongalia, and Wetzel Counties, West Virginia and to make certain modifications to compressor engines at [email protected] or call toll-free, (866) 208-3676 or TTY, (202) 502-8659. Specifically, Equitrans...

  4. 47 CFR 74.1204 - Protection of FM broadcast, FM Translator and LP100 stations.

    Science.gov (United States)

    2010-10-01

    ... 47 Telecommunication 4 2010-10-01 2010-10-01 false Protection of FM broadcast, FM Translator and... SERVICES FM Broadcast Translator Stations and FM Broadcast Booster Stations § 74.1204 Protection of FM broadcast, FM Translator and LP100 stations. (a) An application for an FM translator station will not be...

  5. Norra LP-mudel ajab Eestis juuri / intervjueerinud Sirje Pärismaa

    Index Scriptorium Estoniae

    2016-01-01

    Teaduspõhise LP-mudeli (Learning environment and pedagogical analysis) - abivahendi koolikultuuri parandamiseks ja süsteemsemaks lähenemiseks tekkinud probleemidele - on kasutusele võtnud 10 kooli ja 3 lasteaeda. Norra hariduseksperdid Janne Stoen ja Hanna Jahnsen vastasid Õpetajate Lehe küsimustele

  6. 76 FR 57087 - Stone Harbor Investment Partners LP, et al.; Notice of Application

    Science.gov (United States)

    2011-09-15

    ... SECURITIES AND EXCHANGE COMMISSION [Investment Company Act Release No. 29784; File No. 812-13931] Stone Harbor Investment Partners LP, et al.; Notice of Application September 7, 2011. AGENCY: Securities..., or cause more than 10% of the acquired company's voting stock to be owned by investment companies and...

  7. Serum LP(A) levels in randomized healthy men from different European countries

    NARCIS (Netherlands)

    Cigolini, M; Seidell, J C; Zenti, M G; Bonadonna, G; Zambelli, L; Deslypere, J P; Contaldo, F; Cruz, A.; Charzewska, J; Targher, G

    Serum lipoprotein(a) [Lp(a)], blood lipids, serum insulin and anthropometric parameters were determined in randomized samples of 38-year-old men living in six European cities: Ede (The Netherlands), Deinze (Belgium), Warsaw (Poland), Lumiar (Portugal), Verona and Naples (respectively in northern and

  8. 76 FR 41432 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2011-07-14

    ... Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Model Galaxy, Gulfstream... proposed AD. Discussion The Civil Aviation Authority (CAA), which is the aviation authority for Israel, has... Held by Israel Aircraft Industries, Ltd.): Docket No. FAA-2011-0716; Directorate Identifier 2011-NM-013...

  9. 75 FR 57844 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2010-09-23

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... Previously Held by Israel Aircraft Industries, Ltd.): Amendment 39-16438. Docket No. FAA-2010-0555... (Type Certificate previously held by Israel Aircraft Industries, Ltd.) Model Galaxy and Gulfstream 200...

  10. 75 FR 36296 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2010-06-25

    ... Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel Aircraft... contact we receive about this proposed AD. Discussion The Civil Aviation Authority of Israel (CAAI), which is the aviation authority for Israel, has issued Israeli Airworthiness Directive 01-10-01-07R1, dated...

  11. 77 FR 58323 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2012-09-20

    ... Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Airplanes AGENCY... Previously Held by Israel Aircraft Industries, Ltd.) Model Gulfstream G150 airplanes. This proposed AD was.... Discussion The Civil Aviation Authority of Israel (CAAI), which is the aviation authority for Israel, has...

  12. 77 FR 32069 - Airworthiness Directives; Gulfstream Aerospace LP (Type Certificate Previously Held by Israel...

    Science.gov (United States)

    2012-05-31

    ... Aerospace LP (Type Certificate Previously Held by Israel Aircraft Industries, Ltd.) Airplanes AGENCY... previously held by Israel Aircraft Industries, Ltd.) Model Galaxy and Gulfstream 200 airplanes. This proposed... receive about this proposed AD. Discussion The Civil Aviation Authority of Israel (CAAI), which is the...

  13. On Some Isomorphisms between Bounded Linear Maps and Non-Commutative Lp-Spaces

    Directory of Open Access Journals (Sweden)

    E. J. Atto

    2014-04-01

    Full Text Available We define a particular space of bounded linear maps using a Von Neumann algebra and some operator spaces. By this, we prove some isomorphisms, and using interpolation in some particular cases, we get analogue of non-commutative Lp spaces.

  14. Server scheduling in the Lp norm: A rising tide lifts all boat

    NARCIS (Netherlands)

    Bansal, N.; Pruhs, K.R.

    2003-01-01

    Often server systems do not implement the best known algorithms for optimizing average Quality of Service (QoS) out of concern of that these algorithms may be insufficiently fair to individual jobs. The standard method for balancing average QoS and fairness is optimize the Lp metric, 1

  15. Poly-(R)-3-hydroxybutyrates (PHB) are Atherogenic Components of Lipoprotein Lp(a).

    Science.gov (United States)

    Reusch, Rosetta N

    2015-12-01

    The hypothesis is that poly-(R)-3-hydroxybutyrates (PHB), linear polymers of the ketone body, R-3-hydroxybutyrate (R-3HB), are atherogenic components of lipoprotein Lp(a). PHB are universal constituents of biological cells and are thus components of all foods. Medium chain-length PHB (PHB (PHB are highly insoluble in water, but soluble in lipids in which they exhibit a high intrinsic viscosity. They have a higher density than other cellular lipids and they are very adhesive, i.e. they engage in multiple noncovalent interactions with other molecules and salts via hydrogen, hydrophobic and coordinate bonds, thus producing insoluble deposits. Following digestive processes, PHB enter the circulation in chylomicrons and very low density lipoproteins (VLDL). The majority of the PHB (>70%) are absorbed by albumin, which transports them to the liver for disposal. When the amount of PHB in the diet exceed the capacity of albumin to safely remove them from the circulation, the excess PHB remain in the lipid core of LDL particles that become constituents of lipoprotein Lp(a), and contribute to the formation of arterial deposits. In summary, the presence of PHB – water-insoluble, dense, viscous, adhesive polymers – in the lipid cores of the LDL moieties of Lp(a) particles supports the hypothesis that PHB are atherogenic components of Lp(a).

  16. 78 FR 66892 - BASF Plant Science LP; Availability of Plant Pest Risk Assessment and Environmental Assessment...

    Science.gov (United States)

    2013-11-07

    .... Kevin Shea, Administrator, Animal and Plant Health Inspection Service. [FR Doc. 2013-26701 Filed 11-6-13... DEPARTMENT OF AGRICULTURE Animal and Plant Health Inspection Service [Docket No. APHIS-2012-0028] BASF Plant Science LP; Availability of Plant Pest Risk Assessment and Environmental Assessment for...

  17. Survival associated pathway identification with group Lp penalized global AUC maximization

    Directory of Open Access Journals (Sweden)

    Liu Zhenqiu

    2010-08-01

    Full Text Available Abstract It has been demonstrated that genes in a cell do not act independently. They interact with one another to complete certain biological processes or to implement certain molecular functions. How to incorporate biological pathways or functional groups into the model and identify survival associated gene pathways is still a challenging problem. In this paper, we propose a novel iterative gradient based method for survival analysis with group Lp penalized global AUC summary maximization. Unlike LASSO, Lp (p 1. We first extend Lp for individual gene identification to group Lp penalty for pathway selection, and then develop a novel iterative gradient algorithm for penalized global AUC summary maximization (IGGAUCS. This method incorporates the genetic pathways into global AUC summary maximization and identifies survival associated pathways instead of individual genes. The tuning parameters are determined using 10-fold cross validation with training data only. The prediction performance is evaluated using test data. We apply the proposed method to survival outcome analysis with gene expression profile and identify multiple pathways simultaneously. Experimental results with simulation and gene expression data demonstrate that the proposed procedures can be used for identifying important biological pathways that are related to survival phenotype and for building a parsimonious model for predicting the survival times.

  18. 76 FR 25330 - Texas Eastern Transmission, LP; Notice of Request Under Blanket Authorization

    Science.gov (United States)

    2011-05-04

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-216-000] Texas Eastern... Eastern Transmission, LP (Texas Eastern), 5400 Westheimer Court, Houston, Texas 77056, filed in Docket No... in the termination of any services to Texas Eastern's customers, all as more fully set forth in the...

  19. 76 FR 61682 - Panhandle Eastern Pipe Line Company, LP; Notice of Application

    Science.gov (United States)

    2011-10-05

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-546-000] Panhandle Eastern Pipe Line Company, LP; Notice of Application On September 16, 2011, Panhandle Eastern Pipe Line... free). For TTY, call (202) 502-8659. Comment Date: 5 p.m. Eastern Time on October 19, 2011. Dated...

  20. 77 FR 22773 - Texas Eastern Transmission, L.P.; Notice of Response

    Science.gov (United States)

    2012-04-17

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [ Docket No. RP12-318-001] Texas Eastern... order of the Federal Energy Regulatory Commission in the above- captioned proceeding Texas Eastern Transmission, LP (Texas Eastern) submits its response to show cause why it should not be required to file...

  1. 76 FR 14387 - Texas Eastern Transmission, LP; Notice of Request Under Blanket Authorization

    Science.gov (United States)

    2011-03-16

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Docket No. CP11-118-000] Texas Eastern... Eastern Transmission, LP (Texas Eastern), Post Office Box 1642, Houston, Texas 77251-1642, filed in Docket... West Cameron Blocks 566, 565, and 548, offshore Louisiana, under Texas Eastern's blanket certificate...

  2. 76 FR 46287 - Erie Boulevard Hydropower, L.P.; Notice of Availability of Environmental Assessment

    Science.gov (United States)

    2011-08-02

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 2047-049] Erie Boulevard Hydropower, L.P.; Notice of Availability of Environmental Assessment In accordance with the National Environmental Policy Act of 1969 and the Federal Energy Regulatory Commission's (Commission or FERC) regulations...

  3. 76 FR 65717 - Erie Boulevard Hydropower, L.P.; Notice of Availability of Environmental Assessment

    Science.gov (United States)

    2011-10-24

    ... DEPARTMENT OF ENERGY Federal Energy Regulatory Commission [Project No. 2713-082-New York] Erie Boulevard Hydropower, L.P.; Notice of Availability of Environmental Assessment In accordance with the National Environmental Policy Act of 1969 and the Federal Energy Regulatory Commission's (Commission...

  4. 76 FR 65507 - Notice of Petition for Rate Approval; Eagle Ford Midstream, LP

    Science.gov (United States)

    2011-10-21

    ... Petition for Rate Approval; Eagle Ford Midstream, LP Take notice that on October 11, 2011, (Eagle Ford..., and its initial baseline Statement of Operating Conditions. Eagle Ford states that it is an existing..., currently providing intrastate services to its customers. Eagle Ford proposed rates for Section 311...

  5. Modulation of gut barrier function in patients with obstructive jaundice using probiotic LP299v.

    Science.gov (United States)

    Jones, Claire; Badger, Stephen A; Regan, Mark; Clements, Barry W; Diamond, Tom; Parks, Rowan W; Taylor, Mark A

    2013-12-01

    This study aimed to determine the effect of LP229v on intestinal permeability and tumour necrosis factor (TNF) p55 receptor concentrations in patients with obstructive jaundice undergoing biliary drainage. Patients undergoing biliary drainage were recruited and randomized into three groups to receive Lactobacillus plantarum 299v (LP299v), inactivated LP299v (placebo) or water. These were administered daily at noon until 7 days after biliary drainage. Intestinal permeability was measured using the lactulose/mannitol (L/M) dual sugar absorption test on admission, the day before biliary drainage and on days 1 and 7 after biliary drainage. Blood and urine were collected to determine the L/M ratio and the TNF p55 receptor levels at each time point. A total of 25 patients were recruited; 12 had choledocholithiasis and nine had a periampullary tumour. Open surgical biliary drainage was performed in nine patients, endoscopic retrograde cholangiopancreatography in 12 and percutaneous transhepatic cholangiography in two. Five patients received LP299v, five received placebo and seven, water. The median L/M ratio was 0.035 (0.018-0.065) at baseline. No difference existed between the groups on admission, before drainage and on day 7 after drainage (P=0.59, 0.175 and 0.61, respectively). The L/M ratio was lower in the LP299v group on day 1 after drainage [0.01 (0.01) vs. 0.18 (0.03-0.3) and 0.11 (0.07-0.14); P=0.37]. Although the TNF p55 receptor levels were lower on day 1 after drainage in the LP299v group (15.3 vs. 30.9 vs. 82.7 ng/ml; P=0.43), the concentration at the four time points was similar (P=0.24, 0.96, 0.43 and 0.68). Pretreatment with probiotic LP299v improves intestinal permeability after biliary drainage and attenuates the inflammatory response. However, a larger multicentre trial is required to determine the effect on clinical outcome.

  6. Amplitude and Recurrence Time of LP activity at Mt. Etna, Italy

    Science.gov (United States)

    Cauchie, Léna; Saccorotti, Gilberto; Bean, Christopher

    2013-04-01

    The manifestation of Long-Period (LP) activity is attested on many volcanoes worldwide and is thought to be associated with the resonant oscillations of subsurface, fluid-filled, cracks and conduits. Nonetheless the actual source mechanism that originates the resonance is still unclear. Different models have been proposed so far, including (i) fluid flow instabilities as periodic degassing and (ii) brittle failure in viscous magmas. Since LP activity usually precedes and accompanies volcanic eruption, the understanding of these sources is crucial for the hazard assessment and eruption early warning. The work is aimed at improving the understanding of the LP source mechanism through a statistical analysis of detailed LP catalogues. The behaviour of LP activity is compared with the empirical laws governing earthquakes recurrence (e.g., Gutenberg-Richter [GR] and Gamma-law distributions), in order to understand what relationships, if any, exist between these two apparently different earthquake classes. In particular, about 13000 events were detected on Mount Etna in August 2005 through a STA/LTA method. For this given period, the volcano does not present particular sign of unrest. The manifestation of the LP events is sustained in time over all the period of analysis. From the analysis of the directional properties, it turns out that the events of this first catalog propagate from 2 distinct sources . Furthermore, the events exhibit a high degree of waveform similarity, and provide a criterion for classification/source separation. The events were then grouped into families of comparable waveforms, resulting also in a separation for their source locations. We then used template signals of each family for a Matched-Filtering of the continuous data streams, in order to discriminate small-amplitude events previously undetected by the STA/LTA triggering method. This procedure allowed for a significant enrichment of the catalogues. The retrieved amplitude distributions

  7. Bilateral Breast Enlargement: An Unusual Presentation of Superior Vena Cava Obstruction in a Hemodialysis Patient with Fibrosing Mediastinitis

    International Nuclear Information System (INIS)

    Goo, Dong Erk; Kim, Yong Jae; Choi, Deuk Lin; Kwon, Kui Hyang; Yang, Seung Boo

    2011-01-01

    A 67-year-old woman with end-stage renal disease presented with profound edema of both breasts. The presence of a patent hemodialysis basilic transposition fistula and superior vena cava obstruction (SVC), due to fibrosing mediastinitis, was demonstrated by the use of fistulography. Endovascular treatment with a balloon and stent caused immediate resolution of the breast edema.

  8. Cerebral Fat Embolism in a Trauma Patient with Captured Imaging of Echogenic Emboli in the Inferior Vena Cava

    Directory of Open Access Journals (Sweden)

    Nancy N. Wang

    2016-12-01

    Full Text Available The authors present a case of fat embolism syndrome after traumatic long-bone fracture in a patient with rapid neurologic deterioration and multiple cerebral embolic events. Diagnostic workup revealed the neuroradiologic findings classically described with cerebral fat emboli. The authors present hallmark ultrasound imaging of echogenic material actively traveling through the inferior vena cava.

  9. Adult Wilms tumor with inferior vena cava thrombus and distal deep vein thrombosis - a case report and literature review.

    Science.gov (United States)

    Ratajczyk, Krzysztof; Czekaj, Adrian; Rogala, Joanna; Kowal, Pawel

    2018-02-23

    Adult Wilms tumor (WT, nephroblastoma) is a rare, but well-described renal neoplasm. Although inferior vena cava tumor thrombosis is present in up to 10% of Wilms tumors in childhood, only few cases of this clinical manifestation in adults have been reported. To the best of our knowledge, this is the first case of adult WT infiltrating into inferior vena cava (IVC) with concomitant distal deep vein thrombosis. A 28-year-old male patient with gross hematuria and right flank pain was diagnosed with right kidney tumor penetrating to IVC. Preoperatively, acute distal thrombosis in inferior vena cava and lower extremities veins occurred. Right radical nephrectomy with tumor thrombectomy via cavotomy was performed. In order to prevent pulmonary embolism, IVC was ligated below left renal vein level. Histopathological examination revealed a triphasic nephroblastoma without anaplastic features. Postoperatively, patient was diagnosed with metastatic liver disease, which was treated with two lines of chemotherapy followed by radiotherapy with achievement of complete response. Adult WT occurs usually in young patients, under 40 years of age. Neoadjuvant chemotherapy proved to be effective in children, resulting with tumor shrinkage and venous tumor thrombus regression. Therefore, percutaneous biopsy should be always considered in young patients presenting with renal tumor invading venous system. IVC ligation is a safe treatment option in the event of complete inferior vena cava occlusion due to distal thrombosis concomitant to tumor thrombus, provided collateral venous pathways are well-developed.

  10. Changes in inferior vena cava blood flow velocity and diameter during breathing movements in the human fetus

    NARCIS (Netherlands)

    T. Huisman (T.); S. van den Eijnde (Stefan); P.A. Stewart (Patricia); J.W. Wladimiroff (Juriy)

    1993-01-01

    textabstractBreathing movements in the human fetus cause distinct changes in Doppler flow velocity measurements at arterial, venous and cardiac levels. In adults, breathing movements result in a momentary inspiratory collapse of the inferior vena cava vessel wall. The study objective was to quantify

  11. Learning to perceive and recognize a second language: the L2LP model revised.

    Science.gov (United States)

    van Leussen, Jan-Willem; Escudero, Paola

    2015-01-01

    We present a test of a revised version of the Second Language Linguistic Perception (L2LP) model, a computational model of the acquisition of second language (L2) speech perception and recognition. The model draws on phonetic, phonological, and psycholinguistic constructs to explain a number of L2 learning scenarios. However, a recent computational implementation failed to validate a theoretical proposal for a learning scenario where the L2 has less phonemic categories than the native language (L1) along a given acoustic continuum. According to the L2LP, learners faced with this learning scenario must not only shift their old L1 phoneme boundaries but also reduce the number of categories employed in perception. Our proposed revision to L2LP successfully accounts for this updating in the number of perceptual categories as a process driven by the meaning of lexical items, rather than by the learners' awareness of the number and type of phonemes that are relevant in their new language, as the previous version of L2LP assumed. Results of our simulations show that meaning-driven learning correctly predicts the developmental path of L2 phoneme perception seen in empirical studies. Additionally, and to contribute to a long-standing debate in psycholinguistics, we test two versions of the model, with the stages of phonemic perception and lexical recognition being either sequential or interactive. Both versions succeed in learning to recognize minimal pairs in the new L2, but make diverging predictions on learners' resulting phonological representations. In sum, the proposed revision to the L2LP model contributes to our understanding of L2 acquisition, with implications for speech processing in general.

  12. The effect of an inhibitor of gut serotonin (LP533401) during the induction of periodontal disease.

    Science.gov (United States)

    Lima, G M G; Corazza, B J M; Moraes, R M; de Oliveira, F E; de Oliveira, L D; Franco, G C N; Perrien, D S; Elefteriou, F; Anbinder, A L

    2016-10-01

    LP533401 is an inhibitor of tryptophan hydroxylase 1, which regulates serotonin production in the gut. Previous work indicates that LP533401 has an anabolic effect in bone. Thus, we hypothesized that inhibition of gut serotonin production may modulate the host response in periodontal disease. In this study, we aimed to analyze the effects of LP533401 in a rat periodontitis model to evaluate the role of gut serotonin in periodontitis pathophysiology. Twenty-four rats were divided into three groups: treated group (T: ligature-induced periodontal disease and LP533401, 25 mg/kg/d) by gavage; ligature group (L: ligature-induced periodontal disease only); and control group (C: without ligature-induced periodontal disease). After 28 d, radiographic alveolar bone support was measured on digital radiographs, and alveolar bone volume fraction, tissue mineral density and trabeculae characteristics were quantified by microcomputed tomography in the right hemi-mandible. Left hemi-mandibles were decalcified and alveolar bone loss, attachment loss and area of collagen in the gingiva were histologically analyzed. Significant difference between the L and C groups was found, confirming that periodontal disease was induced. We observed no difference between the T and L groups regarding alveolar bone destruction and area of collagen. LP533401 (25 mg/kg/d) for 28 d does not prevent bone loss and does not modulate host response in a rat model of induced periodontal disease. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  13. The marketing of high-tech innovation: research and teaching as a multidisciplinary communication task

    OpenAIRE

    Hasenauer, Rainer; Fi8lo, Peter; Störi, Herbert

    2013-01-01

    Economically successful high-tech innovation is one of the driving forces for global welfare. Like innovation half-life, break-even time to market or technology acceptance, effective multidisciplinary communication between engineering and marketing is a critical success factor. This paper aims to show the requirements of multidisciplinary communication in B2B marketing of high-tech innovation and methodical approaches in research and academic education: 1. Requirements in high-tech innovat...

  14. The FinTech phenomenon: antecedents of financial innovation perceived by the popular press

    OpenAIRE

    Zavolokina, Liudmila; Dolata, Mateusz; Schwabe, Gerhard

    2016-01-01

    The financial industry has been strongly influenced by digitalization in the past few years reflected by the emergence of 'FinTech,' which represents the marriage of 'finance' and 'information technology.' FinTech provides opportunities for the creation of new services and business models and poses challenges to traditional financial service providers. Therefore, FinTech has become a subject of debate among practitioners, investors, and researchers and is highly visible in the popular media. ...

  15. Measurements of some basic constants of 68Ga(BAT-TECH) as an imaging agent

    International Nuclear Information System (INIS)

    Chen Huawei; Liu Boli

    1994-01-01

    The kinetic properties of a new myocardial imaging agent 68 Ga(BAT-TECH) are investigated and its thermodynamic constants are measured. The results are as follows: Citrate→BAT-TECH exchange reaction order is second-order; reaction rate k = 0.50 l/mol·s; activation energy E a = 56.6 kJ/mol; the stability constant of 68 Ga(BAT-TECH) lgβ = 14.9; the acid dissociation constants of BAT-TECH pK 1 = 4.62, pK 2 = 7.68, pK-3 = 8.68, pK 4 = 11.2

  16. Estimating the Population Impact of Lp(a) Lowering on the Incidence of Myocardial Infarction and Aortic Stenosis

    DEFF Research Database (Denmark)

    Afshar, Mehdi; Kamstrup, Pia R; Williams, Ken

    2016-01-01

    OBJECTIVE: High lipoprotein(a) (Lp[a]) is the most common genetic dyslipidemia and is a causal factor for myocardial infarction (MI) and aortic stenosis (AS). We sought to estimate the population impact of Lp(a) lowering that could be achieved in primary prevention using the therapies in developm......OBJECTIVE: High lipoprotein(a) (Lp[a]) is the most common genetic dyslipidemia and is a causal factor for myocardial infarction (MI) and aortic stenosis (AS). We sought to estimate the population impact of Lp(a) lowering that could be achieved in primary prevention using the therapies...... as measures of the population impact. For MI, the event rate was 4.0% versus 2.8% for high versus low Lp(a) (relative risk, 1.46; 95% confidence interval [CI], 1.45-1.46). The attributable risk was 1.26% (95% CI, 1.24-1.27), corresponding to 31.3% (95% CI, 31.0-31.7) of the excess MI risk in those with high...... and 7.8% for AS. CONCLUSIONS: Lp(a) lowering among the top 20% of the population distribution for Lp(a) could prevent 1 in 14 cases of MI and 1 in 7 cases of AS, suggesting a major impact on reducing the burden of cardiovascular disease. Targeting the top 10% could prevent 1 in 20 MI cases and 1 in 12...

  17. Comparative genome analysis of Lactobacillus plantarum GB-LP3 provides candidates of survival-related genetic factors.

    Science.gov (United States)

    Jeon, Soomin; Jung, Jaehoon; Kim, Kwondo; Yoo, DongAhn; Lee, Chanho; Kang, Jungsun; Cho, Kyungjin; Kang, Dae-Kyung; Kwak, Woori; Yoon, Sook Hee; Kim, Heebal; Cho, Seoae

    2017-09-01

    Lactobacillus plantarum is found in various environmental niches such as in the gastrointestinal tract of an animal host or a fermented food. This species isolated from a certain environment is known to possess a variety of properties according to inhabited environment's adaptation. However, a causal relationship of a genetic factor and phenotype affected by a specific environment has not been systematically comprehended. L. plantarum GB-LP3 strain was isolated from Korean traditional fermented vegetable and the whole genome of GB-LP3 was sequenced. Comparative genome analysis of GB-LP3, with other 14 L. plantarum strains, was conducted. In addition, genomic island regions were investigated. The assembled whole GB-LP3 genome contained a single circular chromosome of 3,206,111bp with the GC content of 44.7%. In the phylogenetic tree analysis, GB-LP3 was in the closest distance from ZJ316. The genomes of GB-LP3 and ZJ316 have the high level of synteny. Functional genes that are related to prophage, bacteriocin, and quorum sensing were found through comparative genomic analysis with ZJ316 and investigation of genomic islands. dN/dS analysis identified that the gene coding for phosphonate ABC transporter ATP-binding protein is evolutionarily accelerated in GB-LP3. Our study found that potential candidate genes that are affected by environmental adaptation in Korea traditional fermented vegetable. Copyright © 2017. Published by Elsevier B.V.

  18. Veia cava superior esquerda anômala com ausência de veia cava superior direita: achados de imagem Persistent left superior vena cava with absent right superior vena cava: image findings

    Directory of Open Access Journals (Sweden)

    Cyrillo Rodrigues de Araújo Júnior

    2003-10-01

    Full Text Available A persistência da veia cava superior esquerda com ausência da veia cava superior direita é uma anomalia rara, com menos de 150 casos descritos na literatura. A não-obliteração e regressão da veia cardinal anterior esquerda durante o desenvolvimento embriológico promove uma variação sistêmica de retorno venoso ao coração, com persistência da veia cava superior esquerda. Sua incidência varia de 0,3% em pacientes sem alterações cardíacas congênitas concomitantes a 4,3% naqueles com cardiopatias. Na maioria das vezes coexiste a veia cava superior direita, porém se houver regressão e degeneração da veia cardinal anterior direita, implicará a sua ausência e a drenagem venosa para o coração será feita pela veia cava superior esquerda ao átrio direito, através do seio coronariano. Mostramos um caso de um paciente submetido a radiografia de tórax e tomografia computadorizada para avaliação de doença pulmonar obstrutiva crônica, tendo como achado a persistência da veia cava superior esquerda com ausência da direita, sem qualquer cardiopatia associada e com a drenagem cardíaca sendo feita, através do seio coronariano, para o átrio direito.Persistent left superior vena cava with absent right superior vena cava is a rare anomaly, with less than 150 cases reported in the literature. Congenitally persistent left superior vena cava is the most common variant of systemic venous return to the heart, resulting embryologically from failure of the left anterior cardinal vein to become obliterated. Its incidence varies from 0.3% in patients with otherwise normal heart to 4.3% in patients with congenital heart disease. In the majority of the patients, a right superior vena cava is present as well, but rarely the right anterior cardinal vein degenerates resulting in the absence of the normal right superior vena cava. The blood from the right side is carried by the persistent left superior vena cava to the right atrium through the

  19. Sequential Venoplasty for Treatment of Inferior Vena Cava Stenosis Following Liver Transplant

    Directory of Open Access Journals (Sweden)

    Ahmad Parvinian

    2014-01-01

    Full Text Available Obstruction of the inferior vena cava (IVC is a rare complication of liver transplantation with significant consequences including intractable ascites and hepatic dysfunction. Although venoplasty and stenting are effective in many cases, patients who fail first-line treatment may require surgical intervention or re-transplantation. Scheduled sequential balloon dilation, an approach frequently used to treat fibrotic, benign biliary strictures, but less commonly vascular lesions, may avert the need for such high-risk alternatives while achieving favorable clinical and angiographic response. Herein, we report the case of a 36-year-old woman with transplant-related, initially angioplasty-resistant IVC stenosis that was successfully treated with sequential balloon dilation.

  20. Brachytherapy for the prevention of neointimal hyperplasia in the canine inferior vena cava after stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Isota, Masayuki; Kaminou, Toshio; Sakai, Yukimasa; Nakamura, Kenji; Yamada, Ryusaku [Osaka City Univ. (Japan). Medical School

    2002-06-01

    The aim of this study was to evaluate the efficacy of brachytherapy for preventing neointimal hyperplasia in the inferior vena cava (IVC) after stent placement. Sixteen beagles underwent Z-stent placement in the IVC and the aorta. For 8 of 16 beagles, irradiation (15 Gy) was delivered endoluminally to the stented segments of each vessel immediately after stent placement using the {sup 192}Ir. All animals were sacrificed after 6 weeks for morphometric and histopathologic examination. Morphometrically, neointimal thickness in the IVC of the radiation group was significantly decreased compared with the control group as well as that in the aorta (p<0.05). Histopathologic findings showed the neointima in the IVC of the control group contained markedly organization of thrombus and neovascularization though that in the IVC of the radiation group consisted mainly of smooth muscle cells without organization of thrombus and neovascularization. From these data intravenous irradiation may prevent clinical restenosis after stent placement. (author)