WorldWideScience

Sample records for vein graft reconstruction

  1. Saphenous vein grafts for perforator flap salvage in autologous breast reconstruction.

    Science.gov (United States)

    Flores, Jaime I; Rad, Ariel N; Shridharani, Sachin M; Stapleton, Sahael M; Rosson, Gedge D

    2009-01-01

    Although the use of saphenous vein grafts in free-flap salvage and extremity replantation is relatively common, their use in breast reconstruction is rare. These two case reports represent extreme alternatives for breast reconstruction flap salvage. In our normal daily practice, the overwhelming majority of elective breast reconstructions proceed smoothly. However, the occasional patient may require saphenous vein graft flap rescue for completion of the reconstruction. (c) 2008 Wiley-Liss, Inc.

  2. Impact of Short Hepatic Vein Reconstruction in Living Donor Adult Liver Transplantation Using a Left Liver Plus Caudate Lobe Graft

    Directory of Open Access Journals (Sweden)

    Koji Mikami

    2010-01-01

    Conclusion: Although no definite advantage from the V1 reconstruction was demonstrated, hepatic vein reconstruction with a significantly-sized short hepatic vein might provide an additional margin of safety for marginally-sized liver grafts during the early phase of graft regeneration.

  3. Leiomyosarcoma of inferior vena cava involving bilateral renal veins: Surgical challenges and reconstruction with upfront saphenous vein interposition graft for left renal vein outflow

    Directory of Open Access Journals (Sweden)

    Rishi Nayyar

    2010-01-01

    Full Text Available Leiomyosarcoma of inferior vena cava (IVC involving bilateral renal veins presents a surgical challenge. Herein, we report the successful management of two such cases using restoration of left renal venous outflow by saphenous vein interposition graft as first step of surgery. Then radical resection of tumor and right kidney was done. IVC was lastly reconstructed using Gore-Tex graft. This report highlights the surgical challenges to ensure radical resection. Furthermore, the importance of restoring left renal outflow in presence of concomitant right nephrectomy is discussed. Both the patients were disease free at six months with no loss of left renal glomerular filtration rate.

  4. Reinforced long saphenous vein bypass graft for infrainguinal reconstruction procedures: case series and literature review.

    LENUS (Irish Health Repository)

    Hynes, Niamh

    2006-03-01

    Poor rehabilitation rates and the high-cost of managing postamputation patients justify an aggressive revascularization policy in critical lower limb ischemia. Endovascular therapy is our first choice for limb salvage in these patients. However there are patients for whom endovascular therapy is not feasible. When bypass is necessary, autologous vein is a superior conduit to synthetic material. However, varicosities usually contraindicate autologous vein bypass because of the risk of aneurysm formation, rupture and increased intimal hyperplasia compared with nonvaricose venous grafts. We report the use of varicosed long saphenous vein (LSV) with external Dacron support in infrainguinal bypass procedures for limb salvage, where endovascular therapy was not feasible. The external Dacron tube was not brought close to the distal anastomotic area itself. With a mean follow-up of 18 months, duplex ultrasonography and computed tomography angiography showed no evidence of stenosis of the reinforced vein segments or aneurysmal degeneration of the residual vein. External reinforcement with Dacron prosthesis allows the use of autogenous greater saphenous veins with varicose dilatation without compromising graft patency and limb salvage.

  5. Simplified one-orifice venoplasty for middle hepatic vein reconstruction in adult living donor liver transplantation using right lobe grafts.

    Science.gov (United States)

    Kim, Joo Dong; Choi, Dong Lak; Han, Young Seok

    2014-05-01

    Middle hepatic vein (MHV) reconstruction is often essential to avoid hepatic congestion and serious graft dysfunction in living donor liver transplantation (LDLT). The aim of this report was to introduce evolution of our MHV reconstruction technique and excellent outcomes of simplified one-orifice venoplasty. We compared clinical outcomes with two reconstruction techniques through retrospective review of 95 recipients who underwent LDLT using right lobe grafts at our institution from January 2008 to April 2012; group 1 received separate outflow reconstruction and group 2 received new one-orifice technique. The early patency rates of MHV in group 2 were higher than those in group 1; 98.4% vs. 88.2% on postoperative day 7 (p = 0.054) and 96.7% vs. 82.4% on postoperative day 14, respectively (p = 0.023). Right hepatic vein (RHV) stenosis developed in three cases in group 1, but no RHV stenosis developed because we adopted one-orifice technique (p = 0.043). The levels of aspartate aminotransferase (AST) and alanine aminotransferase (ALT) in group 2 were significantly lower than those in group 1 during the early post-transplant period. In conclusion, our simplified one-orifice venoplasty technique could secure venous outflow and improve graft function during right lobe LDLT. © 2014 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  6. One-step reconstruction of the right inferior hepatic veins using auto-venous grafts in living-donor liver transplantation.

    Science.gov (United States)

    Ikegami, Toru; Shirabe, Ken; Yoshiya, Shohei; Soejima, Yuji; Yoshizumi, Tomoharu; Uchiyama, Hideaki; Toshima, Takeo; Motomura, Takashi; Maehara, Yoshihiko

    2013-07-01

    Reconstruction of the right inferior hepatic vein (RIHV) presents a major technical challenge in living donor liver transplantation (LDLT) using right lobe grafts. We studied 47 right lobe LDLT grafts with RIHV revascularization, comparing one-step reconstruction, performed post-May 2007 (n = 16), with direct anastomosis, performed pre-May 2007 (n = 31). In the one-step reconstruction technique, the internal jugular vein (n = 6), explanted portal vein (n = 5), inferior vena cava (n = 3), and shunt vessels (n = 2) were used as venous patch grafts for unifying the right hepatic vein, RIHVs, and middle hepatic vein tributaries. By 6 months after LDLT, there was no case of occlusion of the reconstructed RIHVs in the one-step reconstruction group, but a cumulative occlusion rate of 18.2 % in the direct anastomosis group. One-step reconstruction required a longer cold ischemic time (182 ± 40 vs. 115 ± 63, p one-step reconstruction and 83.9 % with direct anastomosis, respectively. One-step reconstruction of the RIHVs using auto-venous grafts is an easy and feasible technique promoting successful right lobe LDLT.

  7. Vein grafting in fingertip replantations.

    Science.gov (United States)

    Yan, Hede; Jackson, William D; Songcharoen, Somjade; Akdemir, Ovunc; Li, Zhijie; Chen, Xinglong; Jiang, Liangfu; Gao, Weiyang

    2009-01-01

    In this retrospective study, the survival rates of fingertip replantation with and without vein grafting were evaluated along with their postoperative functional and cosmetic results. One hundred twenty-one-fingertip amputations were performed in 103 patients between September 2002 and July 2007. Thirty-four amputated fingertips were replanted without vein grafting, while 87 amputated fingertips were replanted with vein grafting for arterial and/or venous repairs. The overall survival rates of the replantations with and without vein grafting were 90% (78/87) and 85% (29/34), respectively. The survival rates were 88% (36/41) with venous repair, 93% (25/27) with arterial repair, and 89% (17/19) with both. Nineteen patients without vein grafting and 48 patients with vein grafting had a follow-up period of more than one year. Good cosmetic and functional outcomes were observed in both groups of patients. The results show that vein grafting is a reliable technique in fingertip replantations, showing no significant difference (P > 0.05) in survival between those with and without vein grafting. Furthermore, no significant difference (P > 0.05) in survival was found between cases with vein grafts for arterial and/or venous repairs. In fingertip replantations with vein grafting, favorable functional and esthetic results can be achieved without sacrificing replantation survival. (c) 2009 Wiley-Liss, Inc.

  8. Kinetics of vein graft hyperplasia

    International Nuclear Information System (INIS)

    Zwolak, R.M.; Adams, M.C.; Clowes, A.W.

    1986-01-01

    Human aortocoronary vein grafts fail due to accelerated occlusive disease. The possibility that this is related to cellular hyperplasia was investigated in a rabbit model where kinetics of vein graft thickening, endothelial (EC) repair, and smooth muscle cell (SMC) proliferation were measured from 2 days to 24 weeks after implanting jugular vein segments in the carotid artery. Immediately after graft placement focal EC denudation was observed. These defects were repaired within 1 week and did not recur. By 4 weeks intimal area had increased 30 fold from 0.028 +/- 0.004 to 0.705 +/- 0.021 mm 2 , and a 24 weeks was 0.93 +/- 0.21 mm 2 . This response did not produce a reduction in graft lumen area. EC and SMC thymidine-labeling index were measured by en face and cross-section autoradiography after injection of 3 H-thymidine and perfusion fixation. Despite rapid EC surface repair EC labeling index remained elevated and only returned to normal levels at 12 weeks; SMC labeling was 10 fold greater than baseline even at 24 weeks (0.22% vs 0.02%). SMC mass demonstrated morphometrically increased between 2 and 12 weeks. Intimal thickening in vein grafts is due to SMC proliferation and develops after the EC layer has been restored. In contrast, intimal SMC proliferate in damaged arteries when the EC layer is absent and cease when the EC layer is regenerated

  9. Improving the Outcome of Vein Grafts: Should Vascular Surgeons Turn Veins into Arteries?

    OpenAIRE

    Isaji, Toshihiko; Hashimoto, Takuya; Yamamoto, Kota; Santana, Jeans M.; Yatsula, Bogdan; Hu, Haidi; Bai, Hualong; Jianming, Guo; Kudze, Tambudzai; Nishibe, Toshiya; Dardik, Alan

    2017-01-01

    Autogenous vein grafts remain the gold standard conduit for arterial bypass, particularly for the treatment of critical limb ischemia. Vein graft adaptation to the arterial environment, i.e., adequate dilation and wall thickening, contributes to the superior performance of vein grafts. However, abnormal venous wall remodeling with excessive neointimal hyperplasia commonly causes vein graft failure. Since the PREVENT trials failed to improve vein graft outcomes, new strategies focus on the ada...

  10. Cartilage grafting in nasal reconstruction.

    Science.gov (United States)

    Immerman, Sara; White, W Matthew; Constantinides, Minas

    2011-02-01

    Nasal reconstruction after resection for cutaneous malignancies poses a unique challenge to facial plastic surgeons. The nose, a unique 3-D structure, not only must remain functional but also be aesthetically pleasing to patients. A complete understanding of all the layers of the nose and knowledge of available cartilage grafting material is necessary. Autogenous material, namely septal, auricular, and costal cartilage, is the most favored material in a free cartilage graft or a composite cartilage graft. All types of material have advantages and disadvantages that should guide the most appropriate selection to maximize the functional and cosmetic outcomes for patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  11. Septal graft in laryngeal reconstruction

    International Nuclear Information System (INIS)

    Bahannan, Abdulrahman; Slavicek, A.; Taudy, M.; Chovanec, M.

    2006-01-01

    A 62-year-old woman presented with symptoms of dyspnea. Ultrasonography and computed tomography examinations revealed mass extending from the cricoid cartilage to the left lobe of thyroid gland and thyroid cartilage. Cytology revealed possibility of cartilaginous origin, which was proven to be chondrosarcoma (Grade 1) from the biopsy specimen obtained during panendosopy. She underwent one stage radical resection and immediate reconstruction of laryngeal skeleton defect by mucocartilaginous graft from the nasal septum. Her postoperative course was optimal with preservation of the laryngeal functions. Twenty-eight months postoperatively, she had to undergo total laryngectomy as a salvage procedure for the advanced local recurrence. We report on the relatively easy technique for functional reconstruction of the large laryngeal defect with the employment cartilage graft from the nasal septum. (author)

  12. Beta irradiation inhibits neo-intimal formation in vein grafts

    International Nuclear Information System (INIS)

    Lang Xiaoou; Ji Shenquan; Zeng Ke; Li Jun; Liu Bingbing; Ma Wenfeng; Zhang Qiang

    2002-01-01

    Objective: The study was to evaluate the effect of beta irradiation on intimal proliferation response in vein grafts. Methods: An autogenous vein graft model was established in 40 rats by transplanting internal branch of jugular vein to carotid artery by end-to-end anastomosis. The vein was irradiated by 32 P before anastomosis. Four dose schedules were studied: (1) control graft (nonirradiated); (2) irradiated with 8 Gy; (3) 18 Gy; and (4) 36 Gy. The grafted veins were harvested at 2 weeks after the operation. IH (intimal hyperplasia) and SMC (smooth muscle cell) proliferation were histologically and immuno-histochemically observed and analyzed by a computer digitalising system. Results: In 18 Gy and 36 Gy-irradiated grafts compared with the control, there was a significant decrease in the average intimal thickness (P 0.05). Immunohistochemical analysis of PCNA indicated decrease of positive cells in both 18 Gy and 36 Gy groups compared with 8 Gy and the control group (P 0.05) groups, and there was also no significant difference between 8 Gy and the control group (P > 0.05). Conclusion: These preliminary results demonstrate that proper dose of beta irradiation in vein graft inhibits smooth muscle cells proliferation and neo-intimal hyperplasia in rat

  13. Graft infections after surgical aortic reconstructions

    OpenAIRE

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open surgical reconstructions as first line of treatment for aorto-iliac diseases. Nowadays, open reconstructions are primarily reserved for patients unsuitable for endovascular reconstructions or for redo ...

  14. Sarpogrelate hydrochloride reduced intimal hyperplasia in experimental rabbit vein graft.

    Science.gov (United States)

    Kodama, Akio; Komori, Kimihiro; Hattori, Keisuke; Yamanouchi, Dai; Kajikuri, Junko; Itoh, Takeo

    2009-05-01

    The selective 5-HT(2A) receptor antagonist sarpogrelate has been clinically used for treatment in atherosclerotic diseases. However, it remains unknown whether administration of sarpogrelate inhibits intimal hyperplasia seen in autologous vein grafts. Therefore, we sought to clarify this question using an experimental rabbit vein graft model. Male rabbits were divided into two groups: a control group and a sarpogrelate-treated group. The jugular vein was interposed in the carotid artery in reversed fashion for 4 weeks and intimal hyperplasia of the grafted vein was measured (n = 8, in each group). Acetylcholine (ACh)-induced endothelium-dependent relaxation was tested by precontraction with prostaglandin F(2alpha) (PGF(2alpha), 5 muM) (n = 5, in each). endothelial nitric oxide synthase (eNOS) protein expression and superoxide production of these veins were also assessed. The suppression of intimal hyperplasia was significantly greater in the sarpogrelate-treated group than in the control group. ACh induced an endothelium-dependent relaxation in the sarpogrelate-treated group (but not in the control group). In endothelium-intact strips from the sarpogrelate-treated group, the nitric oxide (NO) synthase inhibitor nitroarginine enhanced the PGF(2alpha)-induced contraction and blocked the ACh-induced relaxation. Immunoreactive eNOS protein expression was similar between the two groups but superoxide production (estimated from ethidium fluorescence) in endothelial cells was significantly smaller in the sarpogrelate-treated group. The present results indicate that in vivo blockade of 5-HT(2A) receptors leads to an inhibition of intimal hyperplasia in rabbit vein graft. It is suggested that an increased function of endothelium-derived NO through a reduction in endothelial superoxide production may be a possible underlying mechanism for this. These novel findings support the clinical usefulness of sarpogrelate for preventing intimal hyperplasia in vein graft after bypass

  15. Nasolabial facial artery and vein as recipient vessels for midface microsurgical reconstruction.

    Science.gov (United States)

    Oh, Suk Joon; Jeon, Man Kyung; Koh, Sung Hoon

    2011-05-01

    Although free flap transfer is commonly performed to reconstruct facial defects, the submandibular facial artery and vein have historically been considered as adequate recipient vessels for microsurgical reconstruction. If the vascular pedicles of the free flap are short, vein grafts are necessary. The purpose of this study was to determine the indications for and effectiveness of using the nasolabial facial vessels for midfacial reconstruction. A retrospective chart review of 6 patients undergoing microsurgical reconstruction for defects of the face revealed 6 free tissue transfers in which the nasolabial facial artery and vein were considered for use as recipient vessels. Flap success rates were evaluated. Six patients (5 men and 1 woman) underwent 6 free flap transfers. Five anterior helix free flaps were used for the reconstruction of defects in the lower third of the nose. Nasal defects were due to trauma in 4 patients and squamous cell carcinoma in 1 patient. In 1 neurofibromatosis type 1 case, a radial forearm flap was used for reconstruction of the left orbital defect. The facial artery and vein in the nasolabial fold were used as the recipient artery and vein in every case. The mean length of follow-up was 5.8 years. All flaps survived. All patients were satisfied with the degree of aesthetic improvement after surgery.Use of the facial artery and vein in the nasolabial fold for facial reconstruction is reliable and safe. The nasolabial facial artery and vein should be considered as primary recipient vessels in microsurgical reconstruction of the midface.

  16. Graft infections after surgical aortic reconstructions

    NARCIS (Netherlands)

    Berger, P.

    2015-01-01

    Prosthetic vascular grafts are frequently used to reconstruct (part) of the aorta. Every surgical procedure caries a certain risk for infection and when a prosthetic aortic graft is implanted, this may lead to an aortic graft infection (AGI). Endovascular techniques have gradually replaced open

  17. Neointima development in externally stented saphenous vein grafts

    Directory of Open Access Journals (Sweden)

    Przemysław Węglarz

    2016-11-01

    Full Text Available Introduction : The main limitation of coronary artery bypass grafting (CABG is rapid neointimal hyperplasia leading to graft failure. Aim : To assess plaque formation in saphenous vein grafts (SVG covered by an external Dacron stent in comparison with the classical technique. Material and methods : In the study group vein grafts covered by external stent mesh made of Dacron were implanted. An intravascular ultrasonography (IVUS study was performed in 35 aorto-coronary SVG covered by an external Dacron stent and in 64 normal SVG during the first year after CABG. In each SVG 25 mm of good quality IVUS image, volumes of lumen, plaque (neointima, outer border of the vein graft (external SVG and adventitia were calculated in three time periods: 0–130 days, 130–260 days and 260–390 days. Results : Between the first and second time period, lumen volume (mm3 was reduced from 10.33 ±4.4, to 6.80 ±2.23 in the second period and 5.69 ±1.26 in the third one. This effect was much less marked in normal grafts. The corresponding lumen volume (mm3 was: 10.90 ±3.9, 9.15 ±2.94 and 8.92 ±2.93 in consecutive time periods. Plaque volume (mm3 did not change in control grafts during the course of the study, but it increased very significantly in stented grafts from 0.86 ±1.24 in the first period to 2.70 ±1.58 in the second and 3.29 ±2.66 in the third one. Conclusions : The experimental technique of implanting SVG covered with an external elastic Dacron stent seems to be inferior to traditional ones. This is probably due to the more complicated process of vein implantation and higher micro-injury occurrence during the surgery.

  18. A dynamical system that describes vein graft adaptation and failure.

    Science.gov (United States)

    Garbey, Marc; Berceli, Scott A

    2013-11-07

    Adaptation of vein bypass grafts to the mechanical stresses imposed by the arterial circulation is thought to be the primary determinant for lesion development, yet an understanding of how the various forces dictate local wall remodeling is lacking. We develop a dynamical system that summarizes the complex interplay between the mechanical environment and cell/matrix kinetics, ultimately dictating changes in the vein graft architecture. Based on a systematic mapping of the parameter space, three general remodeling response patterns are observed: (1) shear stabilized intimal thickening, (2) tension induced wall thinning and lumen expansion, and (3) tension stabilized wall thickening. Notable is our observation that the integration of multiple feedback mechanisms leads to a variety of non-linear responses that would be unanticipated by an analysis of each system component independently. This dynamic analysis supports the clinical observation that the majority of vein grafts proceed along an adaptive trajectory, where grafts dilate and mildly thicken in response to the increased tension and shear, but a small portion of the grafts demonstrate a maladaptive phenotype, where progressive inward remodeling and accentuated wall thickening lead to graft failure. © 2013 The Authors. Published by Elsevier Ltd. All rights reserved.

  19. Laser-assisted fibrinogen bonding of umbilical vein grafts.

    Science.gov (United States)

    Oz, M C; Williams, M R; Souza, J E; Dardik, H; Treat, M R; Bass, L S; Nowygrod, R

    1993-06-01

    Despite success with autologous tissue welding, laser welding of synthetic vascular prostheses has not been possible. The graft material appears inert and fails to allow the collagen breakdown and electrostatic bonding that results in tissue welding. To develop a laser welding system for graft material, we repaired glutaraldehyde-tanned human umbilical cord vein graft incisions using laser-assisted fibrinogen bonding (LAFB) technology. Modified umbilical vein graft was incised transversely (1.2 cm). Incisions were repaired using sutures, laser energy alone, or LAFB. For LAFB, indocyanine green dye was mixed with human fibrinogen and the compound applied with forceps onto the weld site prior to exposure to 808 nm diode laser energy (power density 4.8 W/cm 2). Bursting pressures for sutured repairs (126.6 +/- 23.4 mm Hg) were similar to LAFB anastomoses (111.6 +/- 55.0 mm Hg). No evidence of collateral thermal injury to the graft material was noted. In vivo evaluation of umbilical graft bonding with canine arteries demonstrates that LAFB can reliably reinforce sutured anastomoses. The described system for bonding graft material with laser exposed fibrinogen may allow creation or reinforcement of vascular anastomoses in procedures where use of autologous tissue is not feasible.

  20. Renal vessel reconstruction in kidney transplantation using a polytetrafluoroethylene (PTFE) vascular graft.

    Science.gov (United States)

    Kamel, Mohamed H; Thomas, Anil A; Mohan, Ponnusamy; Hickey, David P

    2007-04-01

    We report a rare experience in reconstructing short renal vessels in kidney transplantation using polytetrafluroethylene (PTFE) vascular grafts. The short renal vessels in three kidney grafts were managed by the interposition of PTFE vascular grafts. Two grafts were from deceased donors and the third was a renal auto-transplant graft. PTFE grafts were used to lengthen short renal veins in two kidney grafts and a short renal artery in one. The warm ischaemia time was under 1 h and all kidneys functioned well post-operatively. Excellent blood perfusion in the three renal grafts was present on postoperative MAG 3 renal scan. No intra-operative or post-operative complications were encountered. In the three described patients, the use of PTFE vascular graft presented no additional morbidity to the kidney transplant operation and no post-oerative complication was related to its use. However, more data are necessary to conclude that PTFE graft can be used safely in kidney transplantation.

  1. Rule-based model of vein graft remodeling.

    Directory of Open Access Journals (Sweden)

    Minki Hwang

    Full Text Available When vein segments are implanted into the arterial system for use in arterial bypass grafting, adaptation to the higher pressure and flow of the arterial system is accomplished thorough wall thickening and expansion. These early remodeling events have been found to be closely coupled to the local hemodynamic forces, such as shear stress and wall tension, and are believed to be the foundation for later vein graft failure. To further our mechanistic understanding of the cellular and extracellular interactions that lead to global changes in tissue architecture, a rule-based modeling method is developed through the application of basic rules of behaviors for these molecular and cellular activities. In the current method, smooth muscle cell (SMC, extracellular matrix (ECM, and monocytes are selected as the three components that occupy the elements of a grid system that comprise the developing vein graft intima. The probabilities of the cellular behaviors are developed based on data extracted from in vivo experiments. At each time step, the various probabilities are computed and applied to the SMC and ECM elements to determine their next physical state and behavior. One- and two-dimensional models are developed to test and validate the computational approach. The importance of monocyte infiltration, and the associated effect in augmenting extracellular matrix deposition, was evaluated and found to be an important component in model development. Final model validation is performed using an independent set of experiments, where model predictions of intimal growth are evaluated against experimental data obtained from the complex geometry and shear stress patterns offered by a mid-graft focal stenosis, where simulation results show good agreements with the experimental data.

  2. Renal Vein Reconstruction for Harvesting Injury in Kidney Transplantation

    Directory of Open Access Journals (Sweden)

    Birkan Bozkurt

    2014-03-01

    Full Text Available Kidney transplantation is the best treatment choice in the end-stage renal disease. In the renal transplantation, renal vein damage or shortness which occurs during cadaveric or living donor nephrectomy causes technical difficulties for surgeons. The lack of the donors already especially cadaveric, the acquirement of the graft, gets very much importance. In this report, it is aimed to share the clinical experiment by which it seen, how anastomosis can become appropriate by using the renal vein which is damaged in the way that anastomosis cannot be done anyway by using cadaveric vena cava graft. The renal vein brought to length for anostomosis which is repaired by using cadaveric vena cava graft, is anastomosed successfully by becoming an end-to-side of the external iliac vein of the recipient. Vascular anastomoses are applied easily in technique. The time of the warm ischemia was under 2 hours and the kidney was functional in the post-operative period. Renal vein trombosis was not observed. The renal vein damage occured during cadaveric or living donor nephrectomy, can be repaired by some methods. In the kidneys in which vein requirement is done, the success rates are rather high although acute tubular necrosis and delayed function can be seen more.

  3. Aortic reconstruction with bovine pericardial grafts

    Directory of Open Access Journals (Sweden)

    Silveira Lindemberg Mota

    2003-01-01

    Full Text Available INTRODUCTION: Glutaraldehyde-treated crimped bovine pericardial grafts are currently used in aortic graft surgery. These conduits have become good options for these operations, available in different sizes and shapes and at a low cost. OBJECTIVE:To evaluate the results obtained with bovine pericardial grafts for aortic reconstruction, specially concerning late complications. METHOD: Between January 1995 and January 2002, 57 patients underwent different types of aortic reconstruction operations using bovine pericardial grafts. A total of 29 (50.8% were operated on an urgent basis (mostly acute Stanford A dissection and 28 electively. Thoracotomy was performed in three patients for descending aortic replacement (two patients and aortoplasty with a patch in one. All remaining 54 underwent sternotomy, cardiopulmonary bypass and aortic resection. Deep hypothermia and total circulatory arrest was used in acute dissections and arch operations. RESULTS: Hospital mortality was 17.5%. Follow-up was 24.09 months (18.5 to 29.8 months confidence interval and complication-free actuarial survival curve was 92.3% (standard deviation ± 10.6. Two patients lately developed thoracoabdominal aneurysms following previous DeBakey II dissection and one died from endocarditis. One "patch" aortoplasty patient developed local descending aortic pseudoaneurysm 42 months after surgery. All other patients are asymptomatic and currently clinically evaluated with echocardiography and CT scans, showing no complications. CONCLUSION: Use of bovine pericardial grafts in aortic reconstruction surgery is adequate and safe, with few complications related to the conduits.

  4. An unusual case of fistula formation and thrombosis between arteriovenous graft and a native vein

    Directory of Open Access Journals (Sweden)

    Young Sub Kim

    2016-03-01

    Full Text Available Arteriovenous graft for hemodialysis vascular access is a widely used technique with many advantages. However, it has crucial complications with graft thrombosis and infection. We recently experienced an unusual case of arteriovenous graft complication involving graft thrombosis related to fistula formation between the graft and the natural vein with infection. We diagnosed this condition using Doppler ultrasound and computed tomography angiography. Successful surgical treatment including partial graft excision and creation of a secondary arteriovenous fistula using an inadvertently dilated cephalic vein was performed. The dialysis unit staff should keep this condition in mind and try to prevent this complication.

  5. C1-esterase inhibitor protects against early vein graft remodeling under arterial blood pressure.

    Science.gov (United States)

    Krijnen, Paul A J; Kupreishvili, Koba; de Vries, Margreet R; Schepers, Abbey; Stooker, Wim; Vonk, Alexander B A; Eijsman, Leon; Van Hinsbergh, Victor W M; Zeerleder, Sacha; Wouters, Diana; van Ham, Marieke; Quax, Paul H A; Niessen, Hans W M

    2012-01-01

    Arterial pressure induced vein graft injury can result in endothelial loss, accelerated atherosclerosis and vein graft failure. Inflammation, including complement activation, is assumed to play a pivotal role herein. Here, we analyzed the effects of C1-esterase inhibitor (C1inh) on early vein graft remodeling. Human saphenous vein graft segments (n=8) were perfused in vitro with autologous blood either supplemented or not with purified human C1inh at arterial pressure for 6h. The vein segments and perfusion blood were analyzed for cell damage and complement activation. In addition, the effect of purified C1inh on vein graft remodeling was analyzed in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. Application of C1inh in the in vitro perfusion model resulted in significantly higher blood levels and significantly more depositions of C1inh in the vein wall. This coincided with a significant reduction in endothelial loss and deposition of C3d and C4d in the vein wall, especially in the circular layer, compared to vein segments perfused without supplemented C1inh. Administration of purified C1inh significantly inhibited vein graft intimal thickening in vivo in atherosclerotic C57Bl6/ApoE3 Leiden mice, wherein donor caval veins were interpositioned in the common carotid artery. C1inh significantly protects against early vein graft remodeling, including loss of endothelium and intimal thickening. These data suggest that it may be worth considering its use in patients undergoing coronary artery bypass grafting. Copyright © 2011 Elsevier Ireland Ltd. All rights reserved.

  6. Rapamycin treatment is associated with an increased apoptosis rate in experimental vein grafts.

    Science.gov (United States)

    Schachner, Thomas; Oberhuber, Alexander; Zou, Yping; Tzankov, Alexandar; Ott, Harald; Laufer, Günther; Bonatti, Johannes

    2005-02-01

    Rapamycin is an immunosuppressive agent with marked antiproliferative properties and is effective in reducing in stent restenosis and vein graft neointimal hyperplasia. Apoptosis is one mechanism counterbalancing cellular proliferation. We therefore investigated the role of apoptosis in rapamycin treated vein grafts in a mouse model. C57BL6J mice underwent interposition of the inferior vena cava from isogenic donor mice into the common carotid artery using a cuff technique. In the treatment group 200 microg of rapamycin were applied locally in pluronic gel. The control group did not receive local treatment. Vein grafts were harvested at 4 weeks postoperatively and underwent morphometric analysis as well as immunohistochemical analysis for apoptosis (TUNEL). In grafted veins without treatment (controls) neointimal thickness was 50 (12-58) microm at 4 weeks postoperatively. In 200 microg rapamycin treated grafts the neointimal thickness was 17 (5-55) microm. Rapamycin treated vein grafts showed a significantly increased rate of apoptosis in the adventitia as compared with controls (P=0.032). In the neointima the apoptosis rate was lower in both groups with no significant difference between rapamycin treated grafts and controls. We conclude that treatment of experimental vein grafts with rapamycin is associated with an increased apoptosis rate in the vascular wall and a trend towards reduction of neointimal hyperplasia. These results suggest that apoptosis may be a beneficial antiproliferative component for the treatment of vein graft disease.

  7. PTFE Graft as a "Bridge" to Communicating Veins Maturation in the Treatment of an Intrahepatic Cholangiocarcinoma Involving the 3 Hepatic Veins. The Minor-but-Complex Liver Resection.

    Science.gov (United States)

    Urbani, Lucio; Balestri, Riccardo; Sidoti, Francesco; Bernardini, Juri Riccardo; Arces, Francesco; Licitra, Gabriella; Leoni, Chiara; Forfori, Francesco; Colombatto, Piero; Boraschi, Piero; Castagna, Maura; Buccianti, Piero

    2016-12-01

    Parenchyma-sparing liver surgery allows resecting hepatic veins (HV) at the hepatocaval confluence with minor (PTFE graft can be used as a bridge to communicating-veins maturation to ensure the correct outflow of the spared liver. We present a video of an intrahepatic cholangiocarcinoma (IC) involving the three HV at the hepatocaval confluence treated with this approach. In a 50-year old obese (BMI 44.8) male a 6-cm IC involving the hepatocaval confluence was identified during the follow-up for a kidney malignancy. At the preoperative CT scan the left HV was not detectable, the middle HV was incorporated within the tumor, and right HV had a 3-cm contact with the tumor. No communicating veins were evident at preoperative imaging. After a J-shape thoracophrenolaparotomy, the resection of segments II-III-IVa was partially extended to segment VIII-VII and I. The right HV was detached from the tumor, and the middle HV was reconstructed with a 7-mm ringed-armed PTFE graft anastomosed to V8. Surgery lasted 20 h and 55 min with an estimated blood loss of 3500 ml, but the postoperative course was uneventful and the patient was discharged on the 14th postoperative day. One month later the CT scan showed a patent PTFE graft with the maturation of communicating-veins. One year later a complete thrombosis of the PTFE graft was observed with normal liver perfusion and function, and the patient was disease-free. PTFE-based parenchyma-sparing liver resection is a new tool to treat tumors located at the hepatocaval confluence exploiting the maturation of intrahepatic communicating-veins between main HV.

  8. A Rabbit Model for Testing Helper-Dependent Adenovirus-Mediated Gene Therapy for Vein Graft Atherosclerosis

    Directory of Open Access Journals (Sweden)

    Lianxiang Bi

    2017-12-01

    Full Text Available Coronary artery bypass vein grafts are a mainstay of therapy for human atherosclerosis. Unfortunately, the long-term patency of vein grafts is limited by accelerated atherosclerosis. Gene therapy, directed at the vein graft wall, is a promising approach for preventing vein graft atherosclerosis. Because helper-dependent adenovirus (HDAd efficiently transduces grafted veins and confers long-term transgene expression, HDAd is an excellent candidate for delivery of vein graft-targeted gene therapy. We developed a model of vein graft atherosclerosis in fat-fed rabbits and demonstrated long-term (≥20 weeks persistence of HDAd genomes after graft transduction. This model enables quantitation of vein graft hemodynamics, wall structure, lipid accumulation, cellularity, vector persistence, and inflammatory markers on a single graft. Time-course experiments identified 12 weeks after transduction as an optimal time to measure efficacy of gene therapy on the critical variables of lipid and macrophage accumulation. We also used chow-fed rabbits to test whether HDAd infusion in vein grafts promotes intimal growth and inflammation. HDAd did not increase intimal growth, but had moderate—yet significant—pro-inflammatory effects. The vein graft atherosclerosis model will be useful for testing HDAd-mediated gene therapy; however, pro-inflammatory effects of HdAd remain a concern in developing HDAd as a therapy for vein graft disease.

  9. A Rabbit Model for Testing Helper-Dependent Adenovirus-Mediated Gene Therapy for Vein Graft Atherosclerosis.

    Science.gov (United States)

    Bi, Lianxiang; Wacker, Bradley K; Bueren, Emma; Ham, Ervin; Dronadula, Nagadhara; Dichek, David A

    2017-12-15

    Coronary artery bypass vein grafts are a mainstay of therapy for human atherosclerosis. Unfortunately, the long-term patency of vein grafts is limited by accelerated atherosclerosis. Gene therapy, directed at the vein graft wall, is a promising approach for preventing vein graft atherosclerosis. Because helper-dependent adenovirus (HDAd) efficiently transduces grafted veins and confers long-term transgene expression, HDAd is an excellent candidate for delivery of vein graft-targeted gene therapy. We developed a model of vein graft atherosclerosis in fat-fed rabbits and demonstrated long-term (≥20 weeks) persistence of HDAd genomes after graft transduction. This model enables quantitation of vein graft hemodynamics, wall structure, lipid accumulation, cellularity, vector persistence, and inflammatory markers on a single graft. Time-course experiments identified 12 weeks after transduction as an optimal time to measure efficacy of gene therapy on the critical variables of lipid and macrophage accumulation. We also used chow-fed rabbits to test whether HDAd infusion in vein grafts promotes intimal growth and inflammation. HDAd did not increase intimal growth, but had moderate-yet significant-pro-inflammatory effects. The vein graft atherosclerosis model will be useful for testing HDAd-mediated gene therapy; however, pro-inflammatory effects of HdAd remain a concern in developing HDAd as a therapy for vein graft disease.

  10. Adolescent External Iliac Artery Trauma: Recurrent Aneurysmal Dilatation of an Iliofemoral Saphenous Vein Graft Treated by Stent-Grafting

    International Nuclear Information System (INIS)

    Lenton, James; Davies, John; Homer-Vanniasinkam, S.; McPherson, Simon

    2008-01-01

    An adolescent male sustained a severe penetrating injury to the external iliac artery. Emergency surgical revascularization was with a reversed long saphenous vein interposition graft. The primary graft and the subsequent revision graft both became aneurysmal. The second graft aneurysm was successfully excluded by endovascular stent-grafts with medium-term primary patency. A venous graft was used initially rather than a synthetic graft to reduce the risk of infection and the potential problems from future growth. Aneurysmal dilatation of venous grafts in children and adolescents is a rare but recognized complication. To the best of our knowledge, exclusion of these aneurysms with stent-grafts has not been previously reported in the adolescent population.

  11. Surgery for acquired cardiovascular disease: antiseptic treatment of contaminated vein grafts.

    Science.gov (United States)

    Schmidt, F P; Peivandi, A A; Kohnen, W; Jansen, B

    2014-04-01

    Saphenous vein grafts harvested for use as bypass conduits can be contaminated intraoperatively, e.g. by being inadvertently dropped to the floor of the operating room (OR). This study was performed to investigate microorganisms most likely contaminating vein grafts and to assess the possible efficacy of measures to treat potentially contaminated vein grafts antiseptically for further use. In a first step we determined the microbiological flora of the OR using surface cultures and cultures from intentionally dropped vein grafts. Several antiseptic agents (PVP-iodine 10%, octenidinhydrochloride 0.1%, polyhexanide 1%) were evaluated for their in vitro efficacy to disinfect artificially contaminated vein segments. The most promising antiseptic regimen was tested on veins contaminated in a real OR setting. Finally, we tested for possible alterations in mechanical properties of the veins caused by antiseptic treatment. Coagulase-negative staphylococci where the predominant bacteria recovered from the OR with 59.9%. Antiseptic treatment with a combination of octenidine and PVP-iodine resulted in a higher rate of negative cultures than any single agent. Treatment of 50 saphenous vein grafts contaminated in the OR with the combination regimen resulted in only 3 positive cultural results within 7 days. Mechanical tear-stress testing comparing antiseptically treated vein grafts with controls showed no difference in their resistance to tear stress. Antiseptic treatment of contaminated vein grafts was shown to be effective in a high percentage of cases without altering mechanical properties of grafts and may be an option for the surgeon in case of a contamination.

  12. Graft fixation in cruciate ligament reconstruction.

    Science.gov (United States)

    Brand, J; Weiler, A; Caborn, D N; Brown, C H; Johnson, D L

    2000-01-01

    Cruciate ligament reconstruction has progressed dramatically in the last 20 years. Anatomic placement of ligament substitutes has fostered rehabilitation efforts that stress immediate and full range of motion, immediate weightbearing, neuromuscular strength and coordination, and early return to athletic competition (3 months). This has placed extreme importance on secure graft fixation at the time of ligament reconstruction. Current ligament substitutes require a bony or soft tissue component to be fixed within a bone tunnel or on the periosteum at a distance from the normal ligament attachment site. Fixation devices have progressed from metal to biodegradable and from far to near-normal native ligament attachment sites. Ideally, the biomechanical properties of the entire graft construct would approach those of the native ligament and facilitate biologic incorporation of the graft. Fixation should be done at the normal anatomic attachment site of the native ligament (aperture fixation) and, over time, allow the biologic return of the histologic transition zone from ligament to fibrocartilage, to calcified fibrocartilage, to bone. The purpose of this article is to review current fixation devices and techniques in cruciate ligament surgery.

  13. Allogenic lyophilized cartilage grafts for craniomaxillofacial reconstruction

    International Nuclear Information System (INIS)

    Pill Hoon Choung

    1999-01-01

    Allogenic lyophilized cartilages were made in our clinic after Sailer methods and some modification. In our clinic, we have used allogenic cartilage grafts on 102 defects of craniomaxillofacial area; 1) for defects from cyst or ameloblastoma, 2) for lack of continuity of the mandible, 3) for rhinoplasty, 4) for paranasal augmentation, 5) for augmentation genioplasty, 6) for reconstruction of orbital floor, 7) for oroantral fistula, 8) for temporal augmentation, 9) for TMJ surgery 10) for condyle defect as a costochondral graft, 11) for filling of tooth socket and alveolus augmentation,12) for correction or orbital height and 13) for guided bone regeneration in peripheral implant. The types of lyophilized cartilage used were chip, sheet and block types developed by freeze-dried methods. Some grafts showed change of ossification, in which case we could perform implant on it. We have good results on reconstruction of craniomaxillofacial defects. Allogenic cartilage have advantages such as 1) it has no immune reaction clinically, 2) it is more tolerable to infection than that of autogenous cartilage, 3) it has character of less resorption which require no over correction, 4) it is easy to manipulate contouring, and 5) it has possibility of undergoing ossification. Allogenic cartilage has been considered as good substitutes for bone. The author would like to report the results on 102 allogenic cartilage have

  14. Long-term engraftment of bone marrow-derived cells in the intimal hyperplasia lesion of autologous vein grafts.

    Science.gov (United States)

    Diao, Yanpeng; Guthrie, Steve; Xia, Shen-Ling; Ouyang, Xiaosen; Zhang, Li; Xue, Jing; Lee, Pui; Grant, Maria; Scott, Edward; Segal, Mark S

    2008-03-01

    Intimal hyperplasia of autologous vein grafts is a critical problem affecting the long-term patency of many types of vascular reconstruction. Within intimal hyperplasia lesions, smooth muscle cells are a major component, playing an essential role in the pathological process. Given that bone marrow-derived cells may differentiate into smooth muscle cells in the neointima of injured arteries, we hypothesized that the bone marrow may serve as a source for some of the smooth muscle cells within intimal hyperplasia lesions of vein grafts. To test this hypothesis, we used an established mouse model for intimal hyperplasia in wild-type mice that had been transplanted with bone marrow from a green fluorescent protein (GFP+/+) transgenic mouse. High-resolution confocal microscopy analysis performed 2 and 8 weeks after grafting demonstrated expression of GFP in 5.4 +/- 0.8% and 11.9 +/- 2.3%, respectively, of smooth muscle cells within intimal hyperplasia lesions. By 16 weeks, GFP expression in smooth muscle cells was not detected by immunohistochemistry; however, real-time PCR revealed that 20.2 +/- 1.7% of the smooth muscle cells captured from the neointima lesion by laser capture microdissection at 16 weeks contained GFP DNA. Our results suggest that bone marrow-derived cells differentiated into smooth muscle cells within the intimal lesion and may provide a novel clinical approach for decreasing intimal hyperplasia in vein grafts.

  15. Thrombosed aneurysm of saphenous vein coronary artery bypass grafting

    Energy Technology Data Exchange (ETDEWEB)

    Queiroz, Rodolfo Mendes; Nastri Filho, Rogerio; Ferez, Marcus Antonio; Costa, Mauro Jose Brandao da; Laguna, Claudio Benedini; Valentin, Marcus Vinicius Nascimento, E-mail: rod_queiroz@hotmail.com [Documenta - Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Departamento de Radiologia e Diagnostico por Imagem; Hospital Sao Francisco, Ribeirao Preto, SP (Brazil). Centro de Terapia Intensiva

    2017-06-15

    We describe the case of a male patient, aged 76 years, referred for cardiac investigation due to retrosternal chest pain and dyspnea. He had a history of acute myocardial infarction and angioplasties in the last 30 years, including a saphenous vein coronary artery bypass grafting (SVCABG). Echocardiogram showed hypoechoic oval formation near the right ventricle, suggesting a pericardial cyst. Computed angiotomography revealed a predominantly fusiform and thrombosed aneurysmal dilation of the SVCABG to the right coronary artery. SVCABG aneurysms are very rare and potentially fatal. They usually appear in the late postoperative period, and patients are often asymptomatic. On radiography, it is frequently presented as enlargement of the mediastinum, with echocardiography, computed tomography and magnetic resonance imaging being very useful for diagnosis. Coronary angiography is the gold standard to detect these cases. Our report illustrates a rare situation arising late from a relatively common surgery. Due to its severity, proper recognition in the routine assessment of patients with a similar history is essential. (author)

  16. [In situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts].

    Science.gov (United States)

    Badretdinov, I A; Pokrovsky, A V

    2015-01-01

    The article presents a review of literature sources covering possibilities of peiforming in situ aortofemoral reconstructions in surgical treatment of infected aortofemoral grafts. This methodology makes it possible to improve the outcomes of treatment for paraprosthetic infection at the expense of decreasing lethality and morbidity, increasing parameters of patency of grafts and lower limb salvage in the remote postoperative period. Mention should be made that in situ secondary aortofemoral reconstructions are fraught with danger of relapsing paraprosthetic infection, therefore many publications are dedicated to search for prostheses most resistant to infection. The article also presents the results of works devoted to the use of various types of prostheses for in situ secondary aortofemoral reconstructions: prostheses made of polytetrafluoroethylene (PTFE), synthetic grafts saturated with various antibacterial drugs and gelatine, cadaveric allografts, synthetic prostheses treated with silver ions, autovenous conduits based on the femoral and popliteal veins.

  17. Fingertip Replantation Using Y-Shaped Vein Graft to Pulp Artery.

    Science.gov (United States)

    Kim, Jun Hyuk; Lee, Young Man

    2015-10-01

    Re-establishing adequate venous outflow is the most important factor for success of fingertip replantation. However, in zone I level, replantation is very difficult, especially in repairing venous circulation. The authors have made an attempt to replantation using Y-shaped vein (YSV) graft to identify and repair veins easily in fingertip replantation. From January 2007 to December 2012, a total of 46 fingertip replantations in 44 consecutive patients with amputations in the Tamai zone I level were performed by using YSV graft. In all patients, arterial anastomosis was performed using YSV graft, and interpositional vein grafts were used for venous repair. The overall success rate of the YSV-grafted replantations was 91.3% (42/46). Postoperative vascular complications occurred in 6 YSV-grafted replantations (13%), and pulp atrophy in the YSV-grafted digits was 9.5% (4/42). Fingertip replantation in zone I level is a difficult territory to a microsurgeon, especially anastomosing veins. However, our YSV grafting technique has shown value in this setting, enabling better esthetic and functional results.

  18. Imaging features of anterior cruciate ligament reconstruction graft insufficiency

    International Nuclear Information System (INIS)

    Shang Yao; Zhang Yue; Tian Chunyan; Zheng Zhuozhao

    2011-01-01

    Objective: To investigate the imaging features of anterior cruciate ligament (ACL) graft insufficiency. Methods: X-Ray and MR imaging examinations in 24 consecutive patients who had ACL reconstructive graft insufficiency were retrospectively evaluated for tunnel position, osteoarthrosis and its related complications. Follow-up arthroscopy showed 16 graft tears and 8 graft laxities. Fisher exact test was used to compare tunnel malpositions, the proportion of graft tear on MRI and osteoarthrosis between graft tear group and graft laxity group. Results: Two malpositions of tibial tunnel and 3 malpositions of femoral tunnel were seen in graft tear group. Three-malpositions of tibial tunnel and 4 malpositions of femoral tunnel were seen in graft laxity group. The proportion of tibial or femoral malposition showed no significant difference between the two groups (P=0.289, P=0.167). In graft tear group, 15 complete graft tears were diagnosed correctly, 1 partial tear was misdiagnosed as normal on MRI. In graft laxity group, 4 grafts were diagnosed as normal and 4 were considered as graft tear on MRI. A significant difference was seen between the two groups (P=0.028) in the proportion of graft tear diagnosed on MRI. Fourteen osteoarthrosis were seen in graft tear group and 5 in graft laxity group. No significant difference was seen between the two groups (P= 0.289) in the proportion of osteoarthrosis. Conclusion: The proportions of tunnel malposition and osteoarthrosis showed no significant difference between the graft tear group and graft Laxity group. Most graft tears can be diagnosed accurately on MRI, but some cases of graft laxity may be misdiagnosed for graft tear. (authors)

  19. Preduodenal superior mesenteric vein and Whipple procedure with vascular reconstruction-A case report.

    Science.gov (United States)

    Höing, Kristina; Ringe, Kristina I; Bektas, Hüseyin; Klempnauer, Jürgen; Jäger, Mark D

    2015-01-01

    Portal vein (PV) disorders are various, but rare. Here, we report a preduodenal superior mesenteric vein (PDSMV) in a patient who underwent a pancreaticoduodenectomy. A 67-year old woman with familial adenomatosis polyposis was suspicious for cancer of the papilla of vater and scheduled for surgery. Pre-operative diagnostic revealed a PDSMV continuing into the left PV. The splenic vein (SV) continued directly into the right PV without forming ananatomic PV confluence. Eight centimetre of the PDSMV were resected during the pancreaticoduodenectomy and reconnected using a polytetrafluoroethylene prosthesis. On day 1, early graft thrombosis was treated by thrombectomy and change to a larger graft. Pathology confirmed a R0-resection of the adenocarcinoma of the papilla of vater (pTis pN0,G2). At three-month follow-up, the patient was cancer-free and clinically asymptomatic, although, a late graft thrombosis with accompanying newly build venous collaterals passing mesenteric blood to the SV were found. Rare PV disorders like a PDSMV do not contradict pancreatic surgery, but should be treated in experienced centres. Skills of SMV/PV reconstruction and its peri-operative management might be beneficial for successful outcome. Despite late graft thrombosis no clinical disadvantage occurred most likely due to preservation of the SV and of potential venous collateral pathways. Extended surgical procedures like a pancreaticoduodenectomy are realisable in patients with PV disorders, but require awareness, adequate radiological interpretation and specific surgical experience for secure treatment. Copyright © 2015 The Authors. Published by Elsevier Ltd.. All rights reserved.

  20. Prospectively randomized clinical trial to compare in situ and reversed saphenous vein grafts for femoropopliteal bypass.

    Science.gov (United States)

    Harris, P L; How, T V; Jones, D R

    1987-04-01

    Two hundred and fifteen femoropopliteal bypass procedures using autologous saphenous vein grafts were randomly allocated to either the reversed or in situ technique. Eleven veins (5 per cent) were rejected at operation on the basis of their small size, nine in the reversed group and two in the in situ group, and there were two (2 per cent) perioperative deaths in each group, leaving 102 reversed and 98 in situ grafts for further study. The cumulative patency at 3 years of the reversed grafts was 77 per cent and that of the in situ grafts was 68 per cent (n.s.). The patency of all grafts was affected adversely by small veins (P less than 0.005), long grafts (P less than 0.05), low volume of blood flow in the grafts (P less than 0.001) and poor run-off (P less than 0.05). These factors influenced the outcome of the in situ and reversed operations to a similar degree and there was no statistically significant difference between them within any subgroup. The mean compliance of the in situ grafts measured 3 months or more after operation with an ultrasonic echo-tracking system was 0.024 +/- 0.01 per cent/mmHg (+/- s.d.) compared with 0.017 +/- 0.01 per cent/mmHg for the reversed grafts (t = 2.43, P less than 0.02). The incidence of fibrous stricture formation as shown by intravenous digital subtraction angiography was 29 per cent in both the reversed and the in situ grafts. The results of the study to date indicate that reversed and in situ vein grafts are equally effective for femoropopliteal bypass.

  1. A new design concept for knitted external vein-graft support mesh.

    Science.gov (United States)

    Singh, Charanpreet; Wang, Xungai

    2015-08-01

    Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh. Copyright © 2015 Elsevier Ltd. All rights

  2. A new method of prefabricated vascularized allogenic bone grafts for maxillo-mandibular reconstruction

    International Nuclear Information System (INIS)

    Pill-Hoon Choung

    1999-01-01

    Although there are various applications of allogenic bone grafts, a new technique of prevascularized lyophilized allogenic bone grafting for maxillo-mandibular reconstruction will be presented. Allogenic bone has been made by author's protocol for jaw defects as a powder, chip or block bone type. The author used lyophilized allogenic bone grafts for discontinuity defects as a block bone. In those cases, neovascularization and resorption of the allogenic bone were important factors for success of grafting. To overcome the problems, the author designed the technique of prefabricated vascularization of allogenic bone, which was lyophilized cranium, with an application of bovine BMP or not. Lyophilized cranial bone was designed for the defects and was put into the scalp. After confirming a hot spot via scintigram several months later, vascularized allogenic bone was harvested pedicled on the parietotemporal fascia based on the superficial temporal artery and vein. Vascularized allogenic cranial bone was rotated into the defect and fixed rigidly. Postoperatively, there was no severe resorption and functional disturbance of the mandible. In this technique, BMP seems to be an important role to help osteogenesis and neovascularization. Eight patients underwent prefabricated vascularization of allogenic bone grafts. Among them, four cases of reconstruction in mandibular discontinuity defects and one case of reconstruction in maxillectomy defect underwent this method, which will be presented with good results. This method may be an alternative technique of microvascular free bone graft

  3. Leiomyosarcoma of the inferior vena cava level II involvement: curative resection and reconstruction of renal veins

    Directory of Open Access Journals (Sweden)

    Wang Quan

    2012-06-01

    Full Text Available Abstract Leiomyosarcoma of the inferior vena cava (IVCL is a rare retroperitoneal tumor. We report two cases of level II (middle level, renal veins to hepatic veins IVCL, who underwent en bloc resection with reconstruction of bilateral or left renal venous return using prosthetic grafts. In our cases, IVCL is documented to be occluded preoperatively, therefore, radical resection of tumor and/or right kidney was performed and the distal end of inferior vena cava was resected and without caval reconstruction. None of the patients developed edema or acute renal failure postoperatively. After surgical resection, adjuvant radiation therapy was administrated. The patients have been free of recurrence 2 years and 3 months, 9 months after surgery, respectively, indicating the complete surgical resection and radiotherapy contribute to the better survival. The reconstruction of inferior vena cava was not considered mandatory in level II IVCL, if the retroperitoneal venous collateral pathways have been established. In addition to the curative resection of IVCL, the renal vascular reconstruction minimized the risks of procedure-related acute renal failure, and was more physiologically preferable. This concept was reflected in the treatment of the two patients reported on.

  4. A Meta-Analysis of Outcomes After In Situ Reconstructions for Aortic Graft Infection.

    Science.gov (United States)

    Batt, Michel; Feugier, Patrick; Camou, Fabrice; Coffy, Amandine; Senneville, Eric; Caillon, Jocelyne; Calvet, Brigitte; Chidiac, Christian; Laurent, Frederic; Revest, Matthieu; Daures, Jean Pierre

    2018-05-01

    To confirm the advantage of in situ reconstruction (ISR) over extra-anatomic reconstruction (EAR) for aortic graft infection and determine the most appropriate conduit including autogenous veins, cryopreserved allografts, and synthetic prosthesis (standard, rifampicin of silver polyesters). A meta-analysis was conducted with rate of mortality, graft occlusion, amputation, and reinfection. A meta-regression was performed with 4 factors: patients' age, presence of prosthetic-duodenal fistula (PDF), virulent organisms, or nonvirulent organisms. In situ reconstruction over EAR seems to favor all events. For the 5 conduits used for ISR, according to operative mortality, age of the patients looks to have a positive correlation only for silver polyester and no conduit present any advantage in the presence of PDF. Reinfection seems to be not significantly different for the 5 conduits, and only autogenous veins appear to have a positive correlation with infecting organisms. In situ reconstruction may be considered as first-line treatment. Our results suggest that silver polyesters appear to be most appropriate for older patients, and in order to limit reinfection, autogenous veins are probably the most suitable conduit.

  5. Evaluation of aortocoronary bypass graft patency by reconstructed CT image

    International Nuclear Information System (INIS)

    Kawakita, Seizaburo; Koide, Takashi; Saito, Yoshio; Yamamoto, Tadao; Iwasaki, Tadaaki

    1982-01-01

    Ten patients were examined in the period of three months from January to March 1981. The patients were operated from 1 month to 7 years before CT. A bypass to the left anterior descending artery (LAD) was grafted in 10 cases, 2 to the right coronary artery (RCA), 4 to an obtuse marginal artery (OM), and 1 to a diagonal artery. Image reconstruction was performed in 10 cases by using an image analytical computer Evaluskop. Appropriate planes for reconstruction were selected by trial and error methods upon observation of CT images. When gained picture of a graft course coincided with surgical records or angiography, the work of building images was concluded. On cross section, grafts to LAD were visualized in all 10 cases: 9 in the entire course and 1 in a proximal part of the graft. Two to RCA, 4 to OM and 1 to a diagonal were also successfully visualized. Reconstruction of graft images succeeded in 9 grafts of 6 cases. The course of a graft could be pursued from the proximal to the distal end adjacent to the cardiac chamber. The picture of a bypass to LAD was visualized in 6 of 10 grafts. Two bypass to RCA could be depicted, and 1 to OM was also found. However 3 to OM and 1 to a diagonal failed to be visualized throughout their courses in reconstructed images. I think that the causes of faillure mainly depended upon the course of the graft. When a graft was running arc-like surrounding the heart chamber, it was very difficult to depict its entire length in reconstructed images, though the graft could be detected in cross sections. These preliminary studies indicated that reconstruction of CT images had some benefits for the pursuit of graft courses. (J.P.N.)

  6. A novel technique for distal fingertip replantation: Polypropylene suture guided interpositional vein graft.

    Science.gov (United States)

    Dadaci, Mehmet; Ince, Bilsev; Altuntas, Zeynep; Bitik, Ozan; Uzun, Hakan; Bilgen, Fatma

    2015-05-04

    Despite current advances in microsurgery, fingertip replantation is still controversial, mainly due to its difficulty and cost. The purpose of this study is to describe a new technique of interposition vein graft guided by polypropylene suture in distal fingertip replantation. A total of eight consecutive Tamai zone 1 fingertip replantations performed by the same author were included. All replantations were performed using interposition vein graft guided by polypropylene suture. This technique involved a vein graft of ∼ 2 cm, with appropriate calibration, obtained from the volar part of the forearm and a 2-0 polyprolene suture passed through the interposition vein graft. Then, a polypropylene suture guide carrying the vein graft was inserted into the artery. The anastomosis was easily performed with the aid of 10-0 or 11-0 nylon in a bloodless medium and without encountering the posterior wall problem. Average surgery time was 2.5 hours (range = 2-3 hours). Among eight Tamai zone 1 replantations, six were successful (75%). There were two replantations lost because of arterial failure. This technique may ease fingertip replantations and increase the success rate for Tamai zone 1 injuries.

  7. Detection of imminent vein graft occlusion: what is the optimal surveillance program?

    Science.gov (United States)

    Tinder, Chelsey N; Bandyk, Dennis F

    2009-12-01

    The prediction of infrainguinal vein bypass failure remains an inexact judgment. Patient demographics, technical factors, and vascular laboratory graft surveillance testing are helpful in identifying a high-risk graft cohort. The optimal surveillance program to detect the bypass at risk for imminent occlusion continues to be developed, but required elements are known and include clinical assessment for new or changes in limb ischemia symptoms, measurement of ankle and/or toe systolic pressure, and duplex ultrasound imaging of the bypass graft. Duplex ultrasound assessment of bypass hemodynamics may be the most accurate method to detect imminent vein graft occlusion. The finding of low graft flow during intraoperative assessment or at a scheduled surveillance study predicts failure; and if associated with an occlusive lesion, a graft revision can prolong patency. The most common abnormality producing graft failure is conduit stenosis caused by myointimal hyperplasia; and the majority can be repaired by an endovascular intervention. Frequency of testing to detect the failing bypass should be individualized to the patient, the type of arterial bypass, and prior duplex ultrasound scan findings. The focus of surveillance is on identification of the low-flow arterial bypass and timely repair of detected critical stenosis defined by duplex velocity spectra criteria of a peak systolic velocity 300 cm/s and peak systolic velocity ratio across the stenosis >3.5-correlating with >70% diameter-reducing stenosis. When conducted appropriately, a graft surveillance program should result in an unexpected graft failure rate of <3% per year.

  8. Early aneurysmal degeneration of femoral vein conduit used for aortoiliac reconstruction in a child

    Directory of Open Access Journals (Sweden)

    Zakariyae Bouziane, MD

    2016-09-01

    Full Text Available We report the case of a 14-year-old boy who underwent an aortobi-iliac bypass with a femoral vein graft. The patient presented with early aneurysmal degeneration of the entire venous graft only 11 months later. He was treated successfully with redo abdominal aortic surgery and a bifurcated Dacron graft.

  9. Oral mucosa grafts for urethral reconstruction

    African Journals Online (AJOL)

    reports reveal that split and full thickness skin grafts from the scrotum, penis, extragenital sites (ureter, saphenous .... Table 1: Summary of the history of oral mucosa grafts for urethroplasty .... advised that care should be taken when suturing the.

  10. A free vein graft cap influences neuroma formation after nerve transection.

    Science.gov (United States)

    Galeano, Mariarosaria; Manasseri, Benedetto; Risitano, Giovanni; Geuna, Stefano; Di Scipio, Federica; La Rosa, Paola; Delia, Gabriele; D'Alcontres, Francesco Stagno; Colonna, Michele R

    2009-01-01

    : Neuroma formation is a major problem in nerve surgery and consensus about its prevention has not been reached. It has been suggested that vein covering can reduce neuroma formation in transected nerves. In this article, the Authors propose an easy and novel method of covering by nerve stump capping with a free vein graft. : Neuroma-like lesions were created on the rat thigh sectioning the femoral nerve above its division in 16 animals. The proximal nerve stump was invaginated into the lumen of a 1.5 cm long femoral free vein graft on the right side, and the vein was closed on itself by microsurgical sutures to form a cap for the nerve stump. On the left side acting as the control neuroma, the nerve was cut and left uncovered. Histological and immunohistochemical assessment was used to quantify the degree of neuroma formation. : Significant differences were found in both neuroma size and axon-glia organization between the treated and control sides indicating that free vein graft capping reduced neuroma formation in comparison to uncovered nerve stumps. : Our results confirm that vein-covering of a transected nerve stump can be effective in reducing neuroma formation. Moreover, unlike previous works that buried the nerve into an adjacent vein left in place, our experiments showed that also the use of a free vein graft cap can hinder neuroma formation. Although translation of rat experiments to the clinics should be dealt with caution, our data suggest a careful clinical use of the technique. (c) 2009 Wiley-Liss, Inc. Microsurgery, 2009.

  11. A different management of saphenous vein graft failure related to cardiac tamponade following coronary surgery

    Directory of Open Access Journals (Sweden)

    Hamit Serdar Başbuğ

    2016-03-01

    Full Text Available Cardiac tamponade is a state of constriction of the heart with an excessive fluid or hematoma resulted from various conditions. Postoperative tamponade can occur after coronary bypass surgery. Despite it is uncommon, its results may have a high risk of mortality and morbidity. Acute postoperative cardiac tamponade reveals a vast spectrum of symptoms. Moreover, a compression over the saphenous vein graft is the worst complication that should be managed without delay. We report a rare case of saphenous vein graft failure due to the cardiac tamponade following a coronary surgery and its management with a practical measure.

  12. Endoscopic Vein Harvesting for Coronary Bypass Grafting: A Blessing or a Trojan Horse?

    Directory of Open Access Journals (Sweden)

    Ryan Accord

    2011-01-01

    Full Text Available Conventional open harvest of the great saphenous vein (GSV during CABG results in approximately 7% donor-site complications. Using endoscopic vein harvesting (EVH the full GSV length can be harvested through a 3 cm incision. This nonsystematic review discusses several key issues concerning EVH, based on an extensive Pubmed search. Found studies show that EVH results in reduced number of wound complications, less postoperative pain, earlier postoperative mobilisation, reduced length of hospital stay, and is more cost-effective. Initial studies did not find significant differences in graft histology, patency, or clinical outcome. However, in 2009 convincing evidence of inferior histological graft properties became available. Furthermore, an observational study showed that EVH resulted in significantly more graft stenosis, was associated with higher mortality, more myocard infarction, and more reinterventions. Most recent publications could not confirm these findings, however larger randomised controlled trials focusing on graft quality are being awaited.

  13. Right adrenal vein: comparison between adaptive statistical iterative reconstruction and model-based iterative reconstruction.

    Science.gov (United States)

    Noda, Y; Goshima, S; Nagata, S; Miyoshi, T; Kawada, H; Kawai, N; Tanahashi, Y; Matsuo, M

    2018-06-01

    To compare right adrenal vein (RAV) visualisation and contrast enhancement degree on adrenal venous phase images reconstructed using adaptive statistical iterative reconstruction (ASiR) and model-based iterative reconstruction (MBIR) techniques. This prospective study was approved by the institutional review board, and written informed consent was waived. Fifty-seven consecutive patients who underwent adrenal venous phase imaging were enrolled. The same raw data were reconstructed using ASiR 40% and MBIR. The expert and beginner independently reviewed computed tomography (CT) images. RAV visualisation rates, background noise, and CT attenuation of the RAV, right adrenal gland, inferior vena cava (IVC), hepatic vein, and bilateral renal veins were compared between the two reconstruction techniques. RAV visualisation rates were higher with MBIR than with ASiR (95% versus 88%, p=0.13 in expert and 93% versus 75%, p=0.002 in beginner, respectively). RAV visualisation confidence ratings with MBIR were significantly greater than with ASiR (pASiR (pASiR (p=0.0013 and 0.02). Reconstruction of adrenal venous phase images using MBIR significantly reduces background noise, leading to an improvement in the RAV visualisation compared with ASiR. Copyright © 2018 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  14. The effects of vasoactive agents on flow through saphenous vein grafts during lower-extremity peripheral vascular surgery.

    Science.gov (United States)

    Maslow, Andrew D; Bert, Arthur; Slaiby, Jeffrey; Carney, William; Marcaccio, Edward

    2007-06-01

    The purpose of this study was to assess the effects of hemodynamic alterations on vein graft flow during peripheral vascular surgery. It was hypothesized that vasopressors can be administered without compromising flow through the vein grafts. Tertiary care center, university medical center. Randomized placebo-controlled double-blinded study. The effects of phenylephrine, epinephrine, milrinone, intravenous fluid, and placebo on newly constructed peripheral vein grafts were assessed in 60 patients (12 patients in each of 5 groups). Systemic and central hemodynamics were measured by using intra-arterial and pulmonary artery catheters. Vein graft flow was measured by using a transultrasonic flow probe (Transultrasonic Inc, Ithaca, NY). Phenylephrine increased systemic mean blood pressure (mBP) (68.2-94.0 mmHg, p < 0.01), systemic vascular resistance (SVR) (1,091-1,696 dynes x sec x cm(-5), p < 0.001), and vein graft flow (39.5-58.9 mL/min, p < 0.01), whereas cardiac output remained unchanged. Epinephrine resulted in increased cardiac output (4.4-6.9 L/min, p < 0.01) and mBP (72.7-89.1 mmHg, p < 0.01), whereas vein graft flow was reduced in 6 of 12 patients. Intravenous fluid administration resulted in a relatively smaller increase in graft flow (37.6-46.0 mL/min, p < 0.05), an increase in cardiac output, and an insignificant decrease in SVR. Other treatments had either little or no effect on vein graft flow. The study hypothesis was partly supported. Although both phenylephrine and epinephrine increased blood pressure, only the former increased vein graft flow in all patients. In conjunction with increases in graft flow after fluid administration, these data suggest that factors affecting vein graft flow are not just simply related to systemic hemodynamics.

  15. Inhibition of vein graft intimal and medial thickening by periadventitial application of a sulfated carbohydrate polymer

    NARCIS (Netherlands)

    Toes, GT; Barnathan, ES; Liu, HG; Raghunath, PN; Tomaszewski, JE; Caron, RJ; Weisz, PB; vanOeveren, W; Golden, MA

    Purpose: The purpose of this study was to determine whether the wall thickening observed in vein grafts after they were placed into the arterial circulation could be inhibited by periadventitial delivery of an insoluble sulfated polymer of beta-cyclodextrin (P-CDS) capable of tightly binding heparin

  16. Uncommon Case of a Post-Traumatic Portal Vein Pseudoaneurysm Treated with Percutaneous Transhepatic Stent Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Ierardi, Anna Maria, E-mail: amierardi@yahoo.it [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy); Berselli, Mattia, E-mail: mattia.berselli@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Cuffari, Salvatore, E-mail: salvatore.cuffari@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Anesthesiology Department (Italy); Castelli, Patrizio, E-mail: patrizio.castelli@uninsubria.it [Uninsubria, Ospedale di Circolo, Department of Vascular Surgery (Italy); Cocozza, Eugenio, E-mail: eugenio.cocozza@ospedale.varese.it [Uninsubria, Ospedale di Circolo, Department of Surgery (Italy); Carrafiello, Gianpaolo, E-mail: gcarraf@gmail.com [Uninsubria, Ospedale di Circolo, Interventional Radiology Unit (Italy)

    2016-10-15

    We describe a man who presented with a traumatic portal vein pseudoaneurysm, which was subsequently managed with a percutaneous transhepatic stent graft. This case demonstrates a rarely seen condition in the traumatic population and a novel management strategy, which should be considered in the management of this challenging injury.

  17. Arterial Blood Pressure Induces Transient C4b-Binding Protein in Human Saphenous Vein Grafts.

    Science.gov (United States)

    Kupreishvili, Koba; Meischl, Christof; Vonk, Alexander B A; Stooker, Wim; Eijsman, Leon; Blom, Anna M; Quax, Paul H A; van Hinsbergh, Victor W M; Niessen, Hans W M; Krijnen, Paul A J

    2017-05-01

    Complement is an important mediator in arterial blood pressure-induced vein graft failure. Previously, we noted activation of cell protective mechanisms in human saphenous veins too. Here we have analyzed whether C4b-binding protein (C4bp), an endogenous complement inhibitor, is present in the vein wall. Human saphenous vein segments obtained from patients undergoing coronary artery bypass grafting (n = 55) were perfused in vitro at arterial blood pressure with either autologous blood for 1, 2, 4, or 6 hr or with autologous blood supplemented with reactive oxygen species scavenger N-acetylcysteine. The segments were subsequently analyzed quantitatively for presence of C4bp and complement activation product C3d using immunohistochemistry. Perfusion induced deposition of C3d and C4bp within the media of the vessel wall, which increased reproducibly and significantly over a period of 4 hr up to 3.8% for C3d and 81% for C4bp of the total vessel area. Remarkably after 6 hr of perfusion, the C3d-positive area decreased significantly to 1.3% and the C4bp-positive area to 19% of the total area of the vein. The areas positive for both C4bp and C3d were increased in the presence of N-acetylcysteine. Exposure to arterial blood pressure leads to a transient presence of C4bp in the vein wall. This may be part of a cell-protective mechanism to counteract arterial blood pressure-induced cellular stress and inflammation in grafted veins. Copyright © 2017 Elsevier Inc. All rights reserved.

  18. Clinicopathological comparisons of open vein harvesting and endoscopic vein harvesting in coronary artery bypass grafting patients in Mashhad.

    Science.gov (United States)

    Amouzeshi, Ahmad; Teshnisi, Mohamad Abbassi; Zirak, Nahid; Shamloo, Alireza Sepehri; Hoseinikhah, Hamid; Alizadeh, Behzad; Moeinipour, Aliasghar

    2016-01-01

    Harvesting of the greater saphenous vein is almost an inevitable part of coronary artery bypass grafting (CABG) operations, and it is done by two main techniques, i.e., conventional or open vein harvesting (OVH) and the minimally-invasive endoscopic vein harvesting (EVH). This study aimed to compare these two techniques in off-pump CABG procedures with respect to clinical and pathological outcomes. This cohort study was conducted on CABG candidates during a one-year period from October 2013 through September 2014 in the Department of Cardiac Surgery at Mashhad University of Medical Sciences. Eighty-seven patients voluntarily underwent EVH, and another 86 patients matched for age, gender, and other cardiovascular risk factors were selected for OVH. They were followed up for six weeks, and the main outcome measures were infections of the wound, pain, duration of hospital stay, and the costs of hospitalization. Paired sample t-test, independent t-test, or their non-parametric equivalents and the chi-squared test were used by SPSS version 17.0 for data analysis. The mean duration of time for vein harvesting was shorter in the EVH group (p < 0.001), and the pain score was lower (p = 0.04). No infections occurred at the site of the wound. The length of hospital stay was not significantly different for the two groups (OVH versus EVH: 8.5 ± 3.3 versus 8.4 ± 3.2 days; p-value: 0.08). Hospitalization costs were significantly higher in the EVH group (OVH versus EVH: 5.8 ± 4.7 versus 7.3 ± 2.0 million Tomman; p-value: 0.008), yet no difference was diagnosed with respect to endothelial damage in the vein grafts harvested by the EVH and OVH techniques. EVH is considered as a minimally invasive and safe vein harvesting technique in our Center, and it can reduce the harvesting time and post-operative pain. In addition, its efficiency was similar to that of OVH.

  19. Topical application of sodium hyaluronate for preventing perivascular adhesion of the vein grafts in rabbits: An experimental study

    Directory of Open Access Journals (Sweden)

    Ming-ke GUO

    2017-10-01

    Full Text Available Objective To explore the effect of topical application of sodium hyaluronate on preventing perivascular adhesion of the vein grafts in rabbits. Methods Thirty-six male New Zealand white rabbits, aged 5 months, were randomly and equally divided into 2 groups: groups A and B. Arterial defect model was established by cutting about 1cm artery from the middle part of the dissected left common carotid artery. A section about 3cm was cut from the right external jugular vein, and the harvested vein was inverted and anastomosed end-to-end to the artery defect. After the anastomosis, the adventitia and two anastomoses of the grafted veins in group A were coated locally with 0.2ml sodium hyaluronate. The grafted veins were obtained 1, 2 and 4 weeks after the operation, with the perivascular adhesion of the vein grafts being examined macroscopically before the resection. HE staining and Masson staining were preformed for histological changes of grafted vein wall and the perivascular adhesion of the vein grafts. At 2, 4 weeks postoperation, the perivascular adhesions of the vein grafts were graded by the grading criteria of adhesion in macroscopic evaluation and histological evaluation. Results At 1, 2 and 4 weeks postoperatively, the macroscopic and histological observation found that the perivascular adhesions in group A were looser than those in group B. The macroscopic grade and histological grade were lower in group A than in group B, there was a significant difference between the two groups at 2 and 4 weeks postoperation (P<0.05. Conclusion Topical application of sodium hyaluronate can reduce the perivascular adhesion and is an ideal treatment strategy for preventing perivascular adhesion of vein grafts. DOI: 10.11855/j.issn.0577-7402.2017.08.14

  20. Pelvic reconstruction with allogeneic bone graft after tumor resection

    Science.gov (United States)

    Wang, Wei; Bi, Wen Zhi; Yang, Jing; Han, Gang; Jia, Jin Peng

    2013-01-01

    OBJECTIVES : Pelvic reconstruction after tumor resection is challenging. METHODS: A retrospective study had been preformed to compare the outcomes among patients who received pelvic reconstructive surgery with allogeneic bone graft after en bloc resection of pelvic tumors and patients who received en bloc resection only. RESULTS: Patients without reconstruction had significantly lower functional scores at 3 months (10 vs. 15, P = 0.001) and 6 months after surgery (18.5 vs. 22, P = 0.0024), a shorter duration of hospitalization (16 day vs. 40 days, P 0.05). CONCLUSIONS : Pelvic reconstruction with allogeneic bone graft after surgical management of pelvic tumors is associated with satisfactory surgical and functional outcomes. Further clinical studies are required to explore how to select the best reconstruction method. Level of Evidence IV, Case Series. PMID:24453659

  1. Optimal Covering Material for Stent-Grafts Placed in the Portal Vein in a Canine Model

    International Nuclear Information System (INIS)

    Ishii, Seigo; Sato, Morio; Sonomura, Tetsuo; Yamada, Katsuyuki; Tanihata, Hirohiko; Ishikawa, Hime; Terada, Masaki; Sahara, Shinya; Kawai, Nobuyuki; Kimura, Masashi; Mori, Ichiro

    2005-01-01

    Purpose. We evaluated the suitability of Dacron, polytetrafluoroethylene (PTFE), and small intestinal submucosa (SIS) as a covering material for stent-grafts placed in the portal vein as compared with a bare stent. Methods. Using 24 beagle dogs, either bare stents or stent-grafts covered with Dacron, PTFE, or SIS were placed in the main trunk of the portal vein in 6 animals each. Portography was performed immediately after stent placement, and at 2, 4, and 12 weeks thereafter. Next, the extracted stents or stent-grafts were examined histopathologically. Neointimal thickness adjacent to the stent wire and at the midportion between the stent wires was compared among the groups. Then, the neointimal thickness at the sub- and supragraft sites was compared between each stent-graft group. Serial changes in the histologic features of the thickened neointima were also investigated. Results. No significant difference was noted in the mean stenotic ratio of the portal vein diameter between the bare stent and PTFE groups, whereas it was significantly higher in the Dacron and SIS groups compared with the bare stent group. In neither of the studies on neointimal thickness adjacent to the stent wire and at the midportion between the stent wires were any significant differences noted between the neointimal thickness of the bare stent group and the sum of the neointimal thickness of the PTFE group, whereas the sum of the neointimal thickness of the Dacron and SIS groups was significantly greater than that of the bare stent group at both sites. In the comparison of the supragraft neointimal thickness, the SIS group showed significantly greater thickness than the PTFE group, while the difference between the Dacron and PTFE groups was not significant. In the comparison of the subgraft neointimal thickness, the Dacron and SIS groups showed significantly greater thickness than the PTFE group. Conclusion. The present results indicate that of the three covering materials examined here

  2. Satisfactory surgical option for cartilage graft absorption in microtia reconstruction.

    Science.gov (United States)

    Han, So-Eun; Oh, Kap Sung

    2016-04-01

    We routinely perform auricular elevation at least 6 months after implantation of framework in microtia reconstruction using costal cartilage. However, in a few cases, cartilage graft absorption has occurred, which has led to contour irregularity with unfavorable long-term results. In the present study, we recount the details of using additional rib cartilage augmentation to achieve an accentuated contour in cartilage graft absorption cases. The cartilage graft absorption was defined as contour irregularity or cartilage graft deformation as evaluated by the surgeon and patient. Depending on the extent of cartilage graft absorption, another rib cartilage framework was added to the previously implanted framework, targeting the absorption area. We used banked cartilage or harvested new cartilage based on three-dimensional rib computed tomography. Additional recontouring of framework was conducted in eight patients who were examined for cartilage graft absorption from 1.5 to 5 years after implantation of the framework. Four patients received additional rib cartilage augmentation and tissue expander insertion simultaneously prior to auricular elevation. Two patients underwent auricular elevation simultaneously. In another two patients, additional rib cartilage augmentation was performed before auricular elevation. The mean follow-up period was 18 months, and in all cases reconstructive results were acceptable. Although further follow-up evaluation is required, additional rib cartilage augmentation is an attractive surgical option for cartilage graft absorption cases. Copyright © 2016 European Association for Cranio-Maxillo-Facial Surgery. Published by Elsevier Ltd. All rights reserved.

  3. Warfarin improves the outcome of infrainguinal vein bypass grafting at high risk for failure.

    Science.gov (United States)

    Sarac, T P; Huber, T S; Back, M R; Ozaki, C K; Carlton, L M; Flynn, T C; Seeger, J M

    1998-09-01

    Patients with marginal venous conduit, poor arterial runoff, and prior failed bypass grafts are at high risk for infrainguinal graft occlusion and limb loss. We sought to evaluate the effects of anticoagulation therapy after autogenous vein infrainguinal revascularization on duration of patency, limb salvage rates, and complication rates in this subset of patients. This randomized prospective trial was performed in a university tertiary care hospital and in a Veterans Affairs Hospital. Fifty-six patients who were at high risk for graft failure were randomized to receive aspirin (24 patients, 27 bypass grafts) or aspirin and warfarin (WAR; 32 patients, 37 bypass grafts). All patients received 325 mg of aspirin each day, and the patients who were randomized to warfarin underwent anticoagulation therapy with heparin immediately after surgery and then were started on warfarin therapy to maintain an international normalized ratio between 2 and 3. Perioperative blood transfusions and complications were compared with the Student t test or with the chi2 test. Graft patency rates, limb salvage rates, and survival rates were compared with the Kaplan-Meier method and the log-rank test. Sixty-one of the 64 bypass grafts were performed for rest pain or tissue loss, and 3 were performed for short-distance claudication. There were no differences between the groups in ages, indications, bypass graft types, risk classifications (ie, conduit, runoff, or graft failure), or comorbid conditions (except diabetes mellitus). The cumulative 5-year survival rate was similar between the groups. The incidence rate of postoperative hematoma (32% vs 3.7%; P = .004) was greater in the WAR group, but no differences were seen between the WAR group and the aspirin group in the number of packed red blood cells transfused, in the incidence rate of overall nonhemorrhagic wound complications, or in the overall complication rate (62% vs 52%). The immediate postoperative primary graft patency rates (97

  4. Vascular Reconstruction Technique Using a Tubular Graft for Leiomyosarcoma of the Inferior Vena Cava: A Case Report

    Directory of Open Access Journals (Sweden)

    C. Higutchi

    Full Text Available Objective/background: This study is a case report that addresses the key aspects of vascular reconstruction, as well as the intraoperative complications, postoperative morbidity, and possibility of adjunctive therapy. Methods: This article reports the case of a 46 year old female patient with a leiomyosarcoma located in the middle segment of the inferior vena cava (between the renal and hepatic veins who underwent surgical resection with vena cava reconstruction and insertion of a tubular graft made of a synthetic material. Results: This case report reveals that surgical resection of the tumor with the insertion of a smaller-caliber tubular graft provide better patency of the vena cava reconstruction, which was maintained for a year after surgery. In addition, the patient was asymptomatic for lower limb edema, despite having a local recurrence after one year. Surgical resection is the treatment of choice for leiomyosarcoma of the inferior vena cava (LIVC and is the only therapy that offers a chance of cure. Several surgical techniques are used for this condition, especially, reconstruction with a vascular graft using natural or synthetic materials. Conclusion: Due to the aggressiveness of the disease, this study suggests that surgical intervention used may have no influence on a patient's survival outcome. However, vascular reconstruction with a smaller-caliber tubular graft may yield a better prognosis for patients in terms of postoperative symptoms, such as edema and thrombosis. Keywords: Inferior vena cava, Leiomyosarcoma, Synthetic vascular grafting

  5. Endovascular treatment of external iliac vein stenosis caused by graft compression after kidney transplantation

    Directory of Open Access Journals (Sweden)

    Willamax Oliveira de Sousa

    2013-06-01

    Full Text Available A 57-year old patient presented with approximately 80% stenosis of the left external iliac vein due to compression by the renal graft after kidney transplantation. The initial clinical manifestation of this vascular complication was progressive edema of the left lower limb, starting in the foot during the immediate postoperative period and reaching the thigh. Renal function also deteriorated during the first four months after transplantation. Venous Doppler ultrasound findings were suggestive of a diagnosis of extrinsic compression by the kidney graft and so phlebography was ordered, confirming stenosis of the left external iliac vein. The patient was initially treated with balloon angioplasty, but there was still residual stenosis so a stent was inserted, eliminating the stenosis. The edema reduced over time and the patient's renal function improved. While vascular complications are rare, and potentially severe, events, success rates are good if treatment is started early.

  6. [Free tissue transfers with lengthening of vascular pedicle using interpositional vein grafts. About 10 cases].

    Science.gov (United States)

    Yeo, S; Perrot, P; Duteille, F

    2010-04-01

    The realization of free flaps with lack of reliable vessels nearby the loss of substance is a difficult problem for plastic surgeons. We report 10 cases of free tissue transfers with a one-stage technique lengthening the vascular pedicle of the free flap with interpositional vein grafts. Taking into consideration the good results and the low rate of morbidity, the authors emphasize the use of this technique rather than a two-stage procedure. Copyright 2009 Elsevier Masson SAS. All rights reserved.

  7. Feasibility of the Use of RapiGraft and Skin Grafting in Reconstructive Surgery

    Directory of Open Access Journals (Sweden)

    Jung Dug Yang

    2016-09-01

    Full Text Available BackgroundSkin grafting is a relatively simple and thus widely used procedure. However, the elastic and structural quality of grafted skin is poor. Recently, various dermal substitutes have been developed to overcome this disadvantage of split-thickness skin grafts. The present study aims to determine the feasibility of RapiGraft as a new dermal substitute.MethodsThis prospective study included 20 patients with partial- or full-thickness skin defects; the patients were enrolled between January 2013 and March 2014. After skin defect debridement, the wound was divided into two parts by an imaginary line. Split-thickness skin grafting alone was performed on one side (group A, and RapiGraft and split-thickness skin grafting were used on the other side (group B. All patients were evaluated using photographs and self-questionnaires. The Manchester scar scale (MSS, a chromameter, and a durometer were used for the scar evaluation. The average follow-up period was 6 months.ResultsThe skin graft take rates were 93% in group A and 89% in group B, a non-significant difference (P=0.082. Statistically, group B had significantly lower MSS, vascularity, and pigmentation results than group A (P<0.05 for all. However, the groups did not differ significantly in pliability (P=0.155.ConclusionsThe present study indicates that a simultaneous application of RapiGraft and a split-thickness skin graft is safe and yields improved results. Therefore, we conclude that the use of RapiGraft along with skin grafting will be beneficial for patients requiring reconstructive surgery.

  8. Degloved foot sole successfully reconstructed with split thickness skin grafts

    NARCIS (Netherlands)

    Janssens, Loes; Holtslag, Herman R.; Schellekens, Pascal P A; Leenen, Luke P H

    2015-01-01

    Introduction The current opinion is that split thickness skin grafts are not suitable to reconstruct a degloved foot sole. The tissue is too fragile to carry full bodyweight; and therefore, stress lesions frequently occur. The treatment of choice is the reuse of the avulsed skin whenever possible,

  9. Vascularized nerve grafts for lower extremity nerve reconstruction.

    Science.gov (United States)

    Terzis, Julia K; Kostopoulos, Vasileios K

    2010-02-01

    Vascularized nerve grafts (VNG) were introduced in 1976 but since then, there have been no reports of their usage in lower extremity reconstruction systematically. The factors influencing outcomes as well as a comparison with conventional nerve grafts will be presented.Since 1981, 14 lower extremity nerve injuries in 12 patients have been reconstructed with VNG. Common peroneal nerve was injured in 12 and posterior tibial nerve in 5 patients. The level of the injury was at the knee or thigh. Twelve sural nerves were used as VNG with or without concomitant vascularized posterior calf fascia.All patients regained improved sensibility and adequate posterior tibial nerve function. For common peroneal nerve reconstructions, all patients with denervation time less than 6 months regained muscle strength of grade at least 4, even when long grafts were used for defects of 20 cm or more. Late cases, yielded inadequate muscle function even with the use of VNG.Denervation time of 6 months or less was critical for reconstruction with vascularized nerve graft. Not only the results were statistically significant compared with late cases, but also all early operated patients achieved excellent results. VNG are strongly recommended in traction avulsion injuries of the lower extremity with lengthy nerve damage.

  10. Effect of Ticagrelor Plus Aspirin, Ticagrelor Alone, or Aspirin Alone on Saphenous Vein Graft Patency 1 Year After Coronary Artery Bypass Grafting: A Randomized Clinical Trial.

    Science.gov (United States)

    Zhao, Qiang; Zhu, Yunpeng; Xu, Zhiyun; Cheng, Zhaoyun; Mei, Ju; Chen, Xin; Wang, Xiaowei

    2018-04-24

    The effect of ticagrelor with or without aspirin on saphenous vein graft patency in patients undergoing coronary artery bypass grafting (CABG) is unknown. To compare the effect of ticagrelor + aspirin or ticagrelor alone vs aspirin alone on saphenous vein graft patency 1 year after CABG. Randomized, multicenter, open-label, clinical trial among 6 tertiary hospitals in China. Eligible patients were aged 18 to 80 years with indications for elective CABG. Patients requiring urgent revascularization, concomitant cardiac surgery, dual antiplatelet or vitamin K antagonist therapy post-CABG, and who were at risk of serious bleeding were excluded. From July 2014 until November 2015, 1256 patients were identified and 500 were enrolled. Follow-up was completed in January 2017. Patients were randomized (1:1:1) to start ticagrelor (90 mg twice daily) + aspirin (100 mg once daily) (n = 168), ticagrelor (90 mg twice daily) (n = 166), or aspirin (100 mg once daily) (n = 166) within 24 hours post-CABG. Neither patients nor treating physicians were blinded to allocation. Primary outcome was saphenous vein graft patency 1 year after CABG (FitzGibbon grade A) adjudicated independently by a committee blinded to allocation. Saphenous vein graft patency was assessed by multislice computed tomographic angiography or coronary angiography. Among 500 randomized patients (mean age, 63.6 years; women, 91 [18.2%]), 461 (92.2%) completed the trial. Saphenous vein graft patency rates 1 year post-CABG were 88.7% (432 of 487 vein grafts) with ticagrelor + aspirin; 82.8% (404 of 488 vein grafts) with ticagrelor alone; and 76.5% (371 of 485 vein grafts) with aspirin alone. The difference between ticagrelor + aspirin vs aspirin alone was statistically significant (12.2% [95% CI, 5.2% to 19.2%]; P aspirin alone was not statistically significant (6.3% [95% CI, -1.1% to 13.7%]; P = .10). Five major bleeding episodes occurred during 1 year of follow-up (3 with

  11. Accuracy of secondary maxillofacial reconstruction with prefabricated fibula grafts using 3D planning and guided reconstruction

    NARCIS (Netherlands)

    Schepers, Rutger H.; Kraeima, Joep; Vissink, Arjan; Lahoda, Lars U.; Roodenburg, Jan L. N.; Reintsema, Harry; Raghoebar, Gerry M.; Witjes, Max J.

    Background: We compared the pre-operative 3D-surgical plan with the surgical outcome of complex two-stage secondary reconstruction of maxillofacial defects using inserted implants in the prefabricated fibula graft. Methods: Eleven reconstructions of maxillofacial defects with prefabricated fibulas

  12. Superior Lower Extremity Vein Graft Bypass Patency among Married Patients with Peripheral Artery Disease.

    Science.gov (United States)

    Lagergren, Emily; Kempe, Kelly; Craven, Timothy E; Kornegay, Susan T; Hurie, Justin B; Garg, Nitin; Velazquez-Ramirez, Gabriela; Edwards, Matthew S; Corriere, Matthew A

    2017-10-01

    Outcome disparities associated with lower extremity bypass (LEB) for peripheral artery disease (PAD) have been identified but are poorly understood. Marital status may affect outcomes through factors related to health risk behaviors, adherence, and access to care but has not been characterized as a predictor of surgical outcomes and is often omitted from administrative data sets. We evaluated associations between marital status and vein graft patency following LEB using multivariable models adjusting for established risk factors. Consecutive patients undergoing autogenous LEB for PAD were identified and analyzed. Survival analysis and Cox proportional hazards models were used to evaluate patency stratified by marital status (married versus single, divorced, or widow[er]) adjusting for demographic, comorbidity, and anatomic factors in multivariable models. Seventy-three participants who underwent 79 autogenous vein LEB had complete data and were analyzed. Forty-three patients (58.9%) were married, and 30 (41.1%) were unmarried. Compared with unmarried patients, married patients were older at the time of their bypass procedure (67.3 ± 10.8 years vs. 62.2 ± 10.6 years; P = 0.05). Married patients also had a lower prevalence of female gender (11.6% vs. 33.3%; P = 0.02). Diabetes, hypertension, hyperlipidemia, and smoking were common among both married and unmarried patients. Minimum great saphenous vein conduit diameters were larger in married versus unmarried patients (2.82 ± 0.57 mm vs. 2.52 ± 0.65 mm; P = 0.04). Twenty-four-month primary patency was 66% for married versus 38% for unmarried patients. In a multivariable proportional hazards model adjusting for proximal and distal graft inflow/outflow, medications, gender, age, race, smoking, diabetes, and minimum vein graft diameter, married status was associated with superior primary patency (hazard ratio [HR] = 0.33; 95% confidence limits [0.11, 0.99]; P = 0.05); other predictive covariates

  13. Cartilage grafting in facial reconstruction with special consideration of irradiated grafts

    International Nuclear Information System (INIS)

    Donald, P.J.

    1986-01-01

    The search for the perfect facial implant for reconstruction of the face continues. Cartilage, once thought to be an undesirable graft material because of its propensity for absorption, has regained popularity in the past decade. Various preparation techniques have been employed to ensure graft sterility and diminished absorption. An improved understanding of cartilage structure and physiology has shed considerable light on the host-graft relationship. Gamma irradiation is a time-honored method of preservation. An experiment was undertaken to investigate the physiology of irradiated cartilage grafts following prolonged implantation on the facial skeleton of sheep and dog. Merthiolate preserved grafts were used as controls. Direct observation, histochemical techniques, autoradiography, and transmission electron micrography were used to determine chondrocyte viability and matrix composition. It was surprising to note that following implantation of 16 to 72 months, complete resorption was seen in 87.7% of the irradiated grafts and in 43.8% of the Merthiolate stored controls. Many of the grafts acquired chondrocytes from the host and produced new proteoglycan matrix as well as undergoing some degree of ossification. A comparison to the clinical situation in humans is made. 98 references

  14. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Directory of Open Access Journals (Sweden)

    Jianlin Tang

    2014-12-01

    Conclusion: The lessons we learned are (1 Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2 Synthetic graft is an alternative for internal jugular vein graft. (3 Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4 It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  15. The treatment of malignant ventricular tachycardia by aorto-coronary saphenous vein bypass graft

    Science.gov (United States)

    Ikram, H.; Jeffery, R. M.; Parkins, R. A.; Makey, A. R.; Emery, E. R. J.; Stone, D. L.

    1974-01-01

    A 61-year-old man with a previous cardiac infarction had at least fifteen attacks of ventricular tachycardia which finally did not respond to either drug or electrical therapy. Angiography showed a blocked right coronary artery and a non-contractile portion of postero-inferior left ventricular wall. An aorto to right coronary saphenous vein bypass graft was inserted, and although attacks of tachycardia occurred following the operation these were of short duration and reverted spontaneously. He has been free of tachycardia for 5 weeks, with a greatly improved effort tolerance. ImagesFig. 2Fig. 3

  16. [Value of preserved saphenous vein graft for the creation of access ports in hemodialyzed patients: report of 309 cases].

    Science.gov (United States)

    Schneider, Marc; Barrou, Benoît; Cluzel, Philippe; Hamani, Aziz; Bitker, Marc-Olivier; Richard, François

    2003-09-01

    Biological grafts are rarely used for the creation of vascular access, despite their many advantages. Our group prefers to use distal vascular accesses with interposition of a biological graft when direct access cannot be achieved. The objective of this study was to determine the long-term patency and the complication rate of a series of 309 vascular access procedures using a preserved saphenous (PS) vein homograft. 410 (27%) of the 1,500 vascular access procedures performed by our group required the use of a graft, including 376 PS vein homografts (25%). This retrospective study comprised complete data collection for 309 arteriovenous fistulas (AVF) using preserved saphenous (PS) vein graft in the forearm performed in 267 patients between 1985 and 2000. Primary patency was defined as the interval between creation of the vascular access and the first complication requiring surgical or radiological correction; secondary patency was defined as the interval between creation and loss of the graft, with or without revision of the fistula. Survival rates were calculated according to the Kaplan-Meier method. Inter-group comparison was performed by the Logrank test and analysis of variance was performed by logistic regression. Primary patency rates were 77%, 40% and 27% at 1,2 and 5 years, respectively. Secondary patency rates were 79% and 47% at 1 year and 5 years, respectively. The thrombosis rate was 42%. Two episodes of thrombosis occurred in 25% of grafts and 3 episodes were observed in 10% of cases. Infection rates were 1.9% postoperatively and 5% after dialysis, respectively. An aneurysm occurred on 10% of grafts. The operator's experience (RR = 1.58; p creation of vascular accesses with similar patency rates to those of prosthetic grafts. Vein grafts present a number of advantages, particularly a greater ease of use facilitating distal implantation of the graft and a low infection rate.

  17. Association of Angiotensin-Converting Enzyme Genotype, Insertion/Deletion Polymorphism and Saphenous Vein Graft Atherosclerosis in Iranian Patients

    Directory of Open Access Journals (Sweden)

    Neda Zeinali

    2015-10-01

    Full Text Available ABSTRACT OBJECTIVE: The aim of this study was to evaluate possible interactions among Angiotensin-I converting enzyme genotype, insertion/deletion polymorphism and atherosclerosis of vein grafts in Iranian patients, and characterize their clinical and demographic profile. METHODS: In this cross-sectional study, patients who underwent coronary artery bypass graft surgery more than five years ago, were included for angiographic analysis. Atherosclerosis was determined by quantitative angiography and adjusted Gensini score. The gene angiotensin converting enzyme I/D polymorphism was detected by polymerase chain reaction. RESULTS: A total of 102 patients participated in this study. Eighty-four patients were male. The frequency distribution of DD, ID and II polymorphism were 23.6%, 62.7% and 13.7% respectively. There were no differences among genotypic groups in age, sex, number of risk factors, number of vein grafts and months since bypass surgery. According to adjusted Gensini score [0.18±0.12 (II vs. 0.11±0.09 (ID and 0.1±0.09 (DD P=0.021] the II genotype was associated with severity of vein graft atherosclerosis. CONCLUSION: Although there are conflicting results about gene angiotensin converting enzyme I/D polymorphism and the degree of venous bypass graft degeneration, this study suggests an association between ACE genotype II and atherosclerosis of saphenous vein grafts, however, large samples considering clinical, demographic and ethnic profile are necessary to confirm these results.

  18. [Reconstruction of the hypopharynx and cervical esophagus using a free jejunal graft].

    Science.gov (United States)

    Pesko, P; Bumbasirević, M; Knezević, J; Dunjić, M; Djukić, V; Simić, A; Stojakov, D; Sabljak, P; Bjelović, M; Janković, Z; Micev, M; Saranović, D

    2000-01-01

    Extensive malignant tumors of the hypopharynx and cervical esophagus continue to challenge surgeons in respect to both type and extent of resection as well as type of reconstruction. In the period between November 1st, 1996 and November 1st, 1998, at our Department, five patients have been operated due to squamocellular carcinoma of the hypopharynx using a free jejunal graft reconstruction method. The first free jejunal graft operation due to hypopharyngeal carcinoma, at the same time the first operation of this kind ever done in our Country, was performed on November 13th, 1998. There were 4 female and one male patient, average age 47.75 years. Disfagia for solid foods was a leading symptom in all patients (mean duration of 3.5 months) and was always accompanied with weight loss (average of 8 kg for two months). In all patients barium swallow, endoscopy, CT as well as intraoperative endoscopy was performed. Radical surgical procedure was always accompanied with the bilateral modified lympf node neck dissection. As a arterial donor vessel superior thyroid artery was used in all patients. As a venous drainage in three patients a external jugular vein was used and in two facial vein. Reconstruction using a free jejunal graft of approximately 25 cm long was performed in all patients creating upper, oropharingeal, anastomosis end to side and distal, esophageal, end to end (in only one patients side to end) using 3/0 apsorbable sutures. Mean duration of the operation was six hours. The postoperative course in all patients was uneventful. On the 9th postoperative day gastrografin and three days later barium swallow radiography was performed as a standard control study. Regular check ups were done on three, six, nine months, year and two years. On all controls all patients were symptom free and feeling well. It is our opinion that in the patients with isolated carcinoma of the hypopharynx due to low morbidity and mortality rate, free jejunal graft method is the surgical

  19. MRI of double-bundle ACL reconstruction: evaluation of graft findings

    Energy Technology Data Exchange (ETDEWEB)

    Kiekara, Tommi; Paakkala, Antti [Tampere University Hospital, Medical Imaging Centre, Tampere (Finland); Jaervelae, Timo [Sports Clinic and Hospital Mehilaeinen, Tampere (Finland); Huhtala, Heini [University of Tampere, School of Health Sciences, Tampere (Finland)

    2012-07-15

    To demonstrate the magnetic resonance imaging (MRI) findings of double-bundle (DB) anterior cruciate ligament (ACL) reconstruction grafts. Sixty-six patients with DB ACL reconstruction were evaluated with MRI 2 years postoperatively. Graft thickness was measured separately by two musculoskeletal radiologists. The MRI findings of graft disruption, signal intensity (SI) changes, cystic degeneration, arthrofibrosis, and impingement were analyzed. The statistical significance of the association between MRI findings was calculated. The mean anteromedial (AM) graft thickness was reduced 9% and the mean posterolateral (PL) graft thickness was reduced 18% from the original graft thickness. Disruption was seen in 3% of AM grafts and 6% of PL grafts and a partial tear in 8 and 23%, respectively. Both grafts were disrupted in 3% of patients. Increased SI was seen in 14% of intact AM grafts and in 60% of partially torn AM grafts (p = 0.032). In PL grafts the increased SI was seen in 51% of the intact grafts and in 93% of the partially torn grafts (p = 0.005). Cystic degeneration was seen in 8% of AM grafts and in 5% of PL grafts. Diffuse arthrofibrosis was seen in 5% of patients and a localized cyclops lesion in 3% of patients. Impingement of the AM graft was seen in 8% of patients. Both grafts were disrupted in 3% of patients. Also, the frequencies of other complications were low. The use of orthogonal sequences in the evaluation of the PL graft SI seems to cause volume-averaging artefacts. (orig.)

  20. Management of complex pediatric laryngotracheal stenosis with skin graft reconstruction.

    Science.gov (United States)

    Bowe, Sarah N; Wentland, Carissa J; Sandhu, G S; Hartnick, Christopher J

    2018-05-01

    For pediatric patients with laryngotracheal stenosis, the ultimate goal is creation of a safe, functional airway. Unfortunately, wound healing in a hollow structure can complicate repair attempts, leading to restenosis. Herein, we present our experience using skin-grafting techniques in two complex pediatric laryngotracheal stenosis cases, leading to successful decannulation or speech production. A chart review was performed examining the evaluation and management of two pediatric patients with laryngotracheal stenosis despite prior reconstructive attempts. Patient history, bronchoscopic evaluation, intra-operative technique, post-operative management, treatment outcomes, and complications were noted. Harvesting and preparation of the split-thickness skin grafts (STSG) proceeded in a similar manner for each case. Stenting material varied based on the clinical scenario. Using this technique, our patient with a Type 3 glottic web achieved substantial improvement in exercise tolerance, as well as vocal strength and quality. In addition, our aphonic patient could vocalize for the first time since her laryngotracheal injury. Temporary endoluminal stenting with skin graft lining can reproduce epithelial continuity and provide "biological inhibition" to enhance the wound healing process. When previous reconstructive efforts have failed, use of STSG can be considered in the management of complex pediatric laryngotracheal stenosis. Copyright © 2018. Published by Elsevier B.V.

  1. Fast magnetic reconstruction of the portal vein with allogeneic blood vessels in canines.

    Science.gov (United States)

    Wang, Shan-Pei; Yan, Xiao-Peng; Xue, Fei; Dong, Ding-Hui; Zhang, Xu-Feng; Ma, Feng; Wang, Hao-Hua; Lv, Yi

    2015-06-01

    The resection and reconstruction of large vessels, including the portal vein, are frequently needed in tumor resection. Warm ischemia before reconstruction might have deleterious effects on the function of some vital organs and therefore, how to reconstruct the vessels quickly after resection is extremely important. The present study was to introduce a new type of magnetic compression anastomosis (MCA) device to establish a quick non-suture anastomosis of the portal vein after resection in canines. The new MCA device consists of a pair of titanium alloy and neodymium-ferrum-boron magnet (Ti-NdFeB) composite rings. The NdFeB magnetic ring as a core of the device was hermetically sealed inside the biomedical titanium alloy case. Twelve canines were divided into two groups: a MCA group in which the end-to-end anastomoses was made with a new device after resection in the portal vein and a traditional manual suture (TMS) group consisted of 6 canines. The anastomosis time, anastomotic patency and quality were investigated at week 24 postoperatively. The portal vein was reconstructed successfully in all of the animals and they all survived. The duration of portal vein anastomosis was significantly shorter in the MCA group than in the TMS group (8.16+/-1.25 vs 36.24+/-2.17 min, PNdFeB composite MCA device was applicable in reconstruction of large vessels after resection. This device was easy to use and the anastomosis was functionally better than the traditional sutured anastomosis.

  2. Radial bone graft usage for nasal septal reconstruction

    Directory of Open Access Journals (Sweden)

    Yakup Cil

    2011-01-01

    Full Text Available Background: Although various techniques have been described for correction of crooked and saddle nose deformities, these problems are challenging with high recurrence and revision rates. Conventional septal surgery may not be adequate for nose reconstruction in crooked and saddle nose deformities. Materials and Methods: Between December 2005 and October 2009, six patients with crooked nose and five patients with saddle nose deformities underwent corrective surgery in our clinic. All patients were male, and the mean age was 21 years (range, 19-23 years. We used rigid radial bone graft to prevent redeviation and recurrence following corrective nasal septal surgery. Results: The mean follow-up period was 28 months, ranging from 18 to 46 months. Mean operation time was 4 hours (3-4.5. All patients healed uneventfully. None of the patients required secondary surgery. Conclusions: We believe that radial bone grafts offer a long lasting support in treatment of challenging cases with crooked and saddle nose deformities.

  3. The sural artery and vein as recipient vessels in free flap reconstruction about the knee.

    Science.gov (United States)

    Johnson, P E; Harris, G D; Nagle, D J; Lewis, V L

    1987-04-01

    The sural artery and vein were used successfully as recipient vessels in nine patients who required free flap reconstruction about the knee. The anatomy of the sural vessels and the potential advantages of their use as free flap recipients are reviewed and discussed. Indications include popliteal vessels that are absent or severely damaged, as determined by preoperative angiography. No anastomotic complications were encountered in this series, indicating that the sural artery and vein can be used successfully as recipient vessels.

  4. Comparison of fractional flow reserve of composite Y-grafts with saphenous vein or right internal thoracic arteries.

    Science.gov (United States)

    Glineur, David; Boodhwani, Munir; Poncelet, Alain; De Kerchove, Laurent; Etienne, Pierre Yves; Noirhomme, Philippe; Deceuninck, Paul; Michel, Xavier; El Khoury, Gebrine; Hanet, Claude

    2010-09-01

    Composite Y-grafts, using the left internal thoracic artery as the inflow, allow a more efficient use of conduits without the need to touch a diseased ascending aorta. Among other conduits, the saphenous vein graft may be an alternative to the radial artery in elderly patients. We evaluated the hemodynamic characteristics of 17 composite Y-grafts made with the left internal thoracic artery anastomosed to the left anterior descending coronary artery in all cases and with either the free right internal thoracic artery (RITA group, n = 10) or a saphenous vein graft (SVG group, n = 7) implanted proximally to the left internal thoracic artery and distally to the circumflex territory 6 months after the operation. At baseline, the pressure gradient measured with a 0.014-inch pressure wire was minimal between the aorta and the internal thoracic artery stem (2 +/- 1 mm Hg), the internal thoracic artery and left anterior descending (4 +/- 2 mm Hg), the internal thoracic artery and left circumflex (3 +/- 1 mm Hg), and the saphenous vein graft and left circumflex (2 +/- 2 mm Hg). During hyperemia induced by adenosine, the pressure gradient increased significantly to 6 +/- 2 mm Hg in the internal thoracic artery stem, 9 +/- 4 mm Hg in the internal thoracic artery and left anterior descending artery, 9 +/- 3 mm Hg in the internal thoracic artery and left circumflex, and 7 +/- 4 mm Hg in the saphenous vein graft and left circumflex. Fractional flow reserve was 0.94 +/- 0.02 in internal thoracic artery stem, 0.90 +/- 0.04 mm Hg in the internal thoracic artery and left anterior descending, 0.91 +/- 0.03 mm Hg in the internal thoracic artery and left circumflex, and 0.92 +/- 0.06 mm Hg in the saphenous vein graft and left circumflex. No difference between the two types of composite Y-grafts was observed for pressure gradients or fractional flow reserve measured in internal thoracic artery stem or in distal branches. Composite Y-grafts with saphenous vein or right internal thoracic

  5. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy – Case report

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B.

    2014-01-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. Conclusion The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival. PMID:25568802

  6. Ligation of superior mesenteric vein and portal to splenic vein anastomosis after superior mesenteric-portal vein confluence resection during pancreaticoduodenectomy - Case report.

    Science.gov (United States)

    Tang, Jianlin; Abbas, Jihad; Hoetzl, Katherine; Allison, David; Osman, Mahamed; Williams, Mallory; Zelenock, Gerald B

    2014-12-01

    62 year old Caucasian female with pancreatic head mass abutting the superior mesenteric vein (SMV) presented with fine needle aspiration biopsy confirmed diagnosis of ductal adenocarcinoma. CT scan showed near complete obstruction of portal vein and large SMV collateral development. After 3 months of neoadjuvant therapy, her portal vein flow improved significantly, SMV collateral circulation was diminished. Pancreaticoduodenectomy (PD) and superior mesenteric portal vein (SMPV) confluence resection were performed; A saphenous vein interposition graft thrombosed immediately. The splenic vein remnant was distended and adjacent to the stump of the portal vein. Harvesting an internal jugular vein graft required extra time and using a synthetic graft posed a risk of graft thrombosis or infection. As a result, we chose to perform a direct anastomosis of the portal and splenic vein in a desperate situation. The anastomosis decompressed the mesenteric venous system, so we then ligated the SMV. The patient had an uneventful postoperative course, except transient ascites. She redeveloped ascites more than one year later. At that time a PET scan showed bilateral lung and right femur metastatic disease. She expired 15 months after PD. The lessons we learned are (1) Before SMPV confluence resection, internal jugular vein graft should be ready for reconstruction. (2) Synthetic graft is an alternative for internal jugular vein graft. (3) Direct portal vein to SMV anastomosis can be achieved by mobilizing liver. (4) It is possible that venous collaterals secondary to SMV tumor obstruction may have allowed this patient's post-operative survival.

  7. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    Energy Technology Data Exchange (ETDEWEB)

    Borges, Marcela Dias; Aguillera, André Haraguti [Escola Paulista de Medicina, Universidade Federal de São Paulo, São Paulo, SP (Brazil); Brilhante, José Joaquim; Caixeta, Adriano [Hospital Israelita Albert Einstein, São Paulo, SP (Brazil)

    2013-07-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export{sup ™} catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta{sup ™} FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation.

  8. Saphenous vein graft thrombus findings by scanning electron microscopy in a patient with acute myocardial infarction

    International Nuclear Information System (INIS)

    Borges, Marcela Dias; Aguillera, André Haraguti; Brilhante, José Joaquim; Caixeta, Adriano

    2013-01-01

    An eighty-year-old male patient with a history of prior (19 years) coronary artery bypass graft surgery was admitted to the hospital with non ST-segment elevation myocardial infarction (NSTEMI). During the hospital stay he was taking acetylsalicylic acid 100mg per day, a loading dose of 600mg clopidogrel, and low molecular weight heparin 1mg/kg twice a day. Twenty-four hours later the patient underwent coronary angiography, which showed a 90% obstruction in the mid portion of the saphenous vein graft to obtuse marginal with signs of degeneration and local thrombus (Figure 1). Thrombus aspiration was performed with a 6-Fr Export"™ catheter (Medtronic, Santa Rosa, CA, USA), which removed small reddish colored fragments. They were fixed in 2,5% glutaraldehyde in a 0.1M sodium cacodilate buffer. The material was processed following the GOTO protocol in which the fragments were washed with osmium tetroxide and titanic acid, after which they were dried in a critical-point device and a golden bath. Scanning electron microscopy and high definition photos (3,000 to 27,221x magnification) were obtained by the FEI Quanta"™ FEG SEM device (FEI Company, Hillsboro, OR, USA). The images showed that the thrombus was rich in activated platelets, with few erythrocytes or inflammatory cells. Many cholesterol crystals were observed (Figures 2 to). The fibrin networks were sparse and thin, which is compatible with a short ischemic time and recent thrombus formation

  9. Extended Hemi-Hepatectomy with Portal Vein Reconstruction in a Patient with Situs Ambiguous

    Directory of Open Access Journals (Sweden)

    Keishi Sugimachi

    2008-03-01

    Full Text Available We report a case of far-advanced hepatocellular carcinoma (HCC with situs ambiguous, complex visceral and vascular anomalies, who was successfully managed by extended hemi-hepatectomy. A 67-year-old man was referred to our hospital with a large liver mass. Abdominal ultrasonography, computed tomography and angiography revealed HCC with a diameter of 10 cm, with tumor thrombus in the main and first branch of the portal vein. Multiple complex anomalies in the abdomen were determined preoperatively. He had right-sided spleens-stomach-duodenum, liver at midline, inferior vena cava interruption with azygous continuation, and hepatic arterial anomaly. Extended left lobectomy of the liver with reconstruction of the portal vein was performed. Postoperatively, the patient recovered without major complications, and he was discharged on postoperative day 21. We report the first successful extended hepatectomy with portal vein reconstruction for HCC in a patient with rare situs anomalies.

  10. [Transposition of the cephalic vein in free flap breast reconstruction: Technical note].

    Science.gov (United States)

    Silhol, T; Suffee, T; Hivelin, M; Lantieri, L

    2018-02-01

    Free flaps have become a reliable practice for breast reconstruction. However, the venous congestion is still the most frequent reason of flap failure. It is due to bad quality of the internal mammary veins, a preferential superficial venous outflow of the flap or due to venous thrombosis. The transposition of the cephalic vein could useful in some cases. We describe the surgical technique and suggest an intraoperative algorithm. Seventeen patients (15 DIEP and 2 PAP) were included. Twenty nine point four percent had an unusable internal mammary vein, 23.5% a preferential superficial venous outflow and 47.1% a venous thrombosis. The length of the cephalic vein dissected varied from 15 to 25cm. The mean time of dissection was 39min. There was no flap failure after cephalic vein transposition. The sequelae were one or two scars on the arm without any functional morbidity. The transposition of the cephalic vein is a reliable, less morbid alternative in case of bad quality internal mammary vein with a good quality internal mammary artery, in case of an additional venous outflow necessity or in case of venous thrombosis. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  11. The Anatomy of the Facial Vein: Implications for Plastic, Reconstructive, and Aesthetic Procedures.

    Science.gov (United States)

    Cotofana, Sebastian; Steinke, Hanno; Schlattau, Alexander; Schlager, Markus; Sykes, Jonathan M; Roth, Malcolm Z; Gaggl, Alexander; Giunta, Riccardo E; Gotkin, Robert H; Schenck, Thilo L

    2017-06-01

    Anatomical knowledge of the facial vasculature is crucial for successful plastic, reconstructive, and minimally invasive procedures of the face. Whereas the majority of previous investigations focused on facial arteries, the precise course, variability, and relationship with adjacent structures of the facial vein have been widely neglected. Seventy-two fresh frozen human cephalic cadavers (32 male and 40 female cadavers; mean age, 75.2 ± 10.9 years; mean body mass index, 24.2 ± 6.6 kg/m; 99 percent Caucasian ethnicity) were investigated by means of layer-by-layer anatomical dissection. In addition, 10 cephalic specimens were investigated using contrast agent-enhanced computed tomographic imaging. The facial vein displayed a constant course in relation to the adjacent anatomical structures. The vein was identified posterior to the facial artery, anterior to the parotid duct, and deep to the zygomaticus major muscle. The angular vein formed the lateral boundary of the deep medial cheek fat and the premaxillary space, and the medial boundary of the deep lateral cheek fat and the sub-orbicularis oculi fat. The mean distance of the inferior and superior labial veins, of the deep facial vein, and of the angular vein from the inferior orbital margin was 51.6 ± 3.1, 42.6 ± 2.3, 27.4 ± 3.0, and 4.2 ± 0.7 mm, respectively. This work provides detailed information on the course of the facial vein in relation to neighboring structures. The presented clinically relevant anatomical observations and descriptions of landmarks will serve as helpful information for plastic, reconstructive, and aesthetic surgeons.

  12. An External Wire Frame Fixation Method of Skin Grafting for Burn Reconstruction.

    Science.gov (United States)

    Yoshino, Yukiko; Ueda, Hyakuzoh; Ono, Simpei; Ogawa, Rei

    2017-06-28

    The skin graft is a prevalent reconstructive method for burn injuries. We have been applying external wire frame fixation methods in combination with skin grafts since 1986 and have experienced better outcomes in percentage of successful graft take. The overall purpose of this method was to further secure skin graft adherence to wound beds in hard to stabilize areas. There are also location-specific benefits to this technique such as eliminating the need of tarsorrhaphy in periorbital area, allowing immediate food intake after surgery in perioral area, and performing less invasive fixing methods in digits, and so on. The purpose of this study was to clarify its benefits and applicable locations. We reviewed 22 postburn patients with skin graft reconstructions using the external wire frame method at our institution from December 2012 through September 2016. Details of the surgical technique and individual reports are also discussed. Of the 22 cases, 15 (68%) were split-thickness skin grafts and 7 (32%) were full-thickness skin grafts. Five cases (23%) involved periorbital reconstruction, 5 (23%) involved perioral reconstruction, 2 (9%) involved lower limb reconstruction, and 10 (45%) involved digital reconstruction. Complete (100%) survival of the skin graft was attained in all cases. No signs of complication were observed. With 30 years of experiences all combined, we have summarized fail-proof recommendations to a successful graft survival with an emphasis on the locations of its application.

  13. Preauricular full-thickness skin grafting in medial canthal reconstruction

    Directory of Open Access Journals (Sweden)

    Rafael Corredor-Osorio

    2018-02-01

    Full Text Available Basal cell carcinoma in medial canthal is a surgical challenge to oculoplastic surgeon. We report a case an 80 –year-old woman who presented with a vegetative tumor in the right inferior medial canthus that increased slowly in size over the past two years. An excisional biopsy from the tumor was suggestive of a basal cell carcinoma. A full-thickness excision of the tumor within the oncologic safety limits, was performed. A wide range of reconstruction techniques should be customized to the individual patient. In this case, the use of a preauricular full. Thickness skin graft was a favorable option, without complications, and with acceptable functional and cosmetic results. The aim of the treatment is to restore anatomy, functional and cosmetic of the patients.

  14. Temporal network based analysis of cell specific vein graft transcriptome defines key pathways and hub genes in implantation injury.

    Directory of Open Access Journals (Sweden)

    Manoj Bhasin

    Full Text Available Vein graft failure occurs between 1 and 6 months after implantation due to obstructive intimal hyperplasia, related in part to implantation injury. The cell-specific and temporal response of the transcriptome to vein graft implantation injury was determined by transcriptional profiling of laser capture microdissected endothelial cells (EC and medial smooth muscle cells (SMC from canine vein grafts, 2 hours (H to 30 days (D following surgery. Our results demonstrate a robust genomic response beginning at 2 H, peaking at 12-24 H, declining by 7 D, and resolving by 30 D. Gene ontology and pathway analyses of differentially expressed genes indicated that implantation injury affects inflammatory and immune responses, apoptosis, mitosis, and extracellular matrix reorganization in both cell types. Through backpropagation an integrated network was built, starting with genes differentially expressed at 30 D, followed by adding upstream interactive genes from each prior time-point. This identified significant enrichment of IL-6, IL-8, NF-κB, dendritic cell maturation, glucocorticoid receptor, and Triggering Receptor Expressed on Myeloid Cells (TREM-1 signaling, as well as PPARα activation pathways in graft EC and SMC. Interactive network-based analyses identified IL-6, IL-8, IL-1α, and Insulin Receptor (INSR as focus hub genes within these pathways. Real-time PCR was used for the validation of two of these genes: IL-6 and IL-8, in addition to Collagen 11A1 (COL11A1, a cornerstone of the backpropagation. In conclusion, these results establish causality relationships clarifying the pathogenesis of vein graft implantation injury, and identifying novel targets for its prevention.

  15. Simultaneous Iliac Vein Bovine Pericardial Patch Venoplasty and Creation of PTFE Lower Limb Arteriovenous Fistula Graft for Rescue Vascular Access.

    Science.gov (United States)

    Meecham, Lewis; Fisher, Owain; Kirby, George; Evans, Richard; Buxton, Pauline; Legge, Jocelyn; Rajagopalan, Sriram; Asquith, John; Pherwani, Arun

    2016-10-01

    We present a case of external iliac vein patch venoplasty to accommodate rescue vascular access via a polytetrafluoroethylene loop arteriovenous fistula graft (AVG) for a patient with multiple central venous stenoses. A 35-year-old female with anti-glomerular basement membrane antibody disease required rescue vascular access for hemodialysis. Repeated occlusion and/or thrombosis of long-term central venous access cannulae, to facilitate dialysis, had caused stenosis of brachiocephalic veins: right external iliac vein and occlusion of the left common iliac vein. A previous right brachiobasilic fistula had occluded within 1 year. No other upper limb options for arteriovenous fistula (AVF) were available. A right external iliac vein bovine patch angioplasty concurrently with a polytetrafluoroethylene AV graft between common femoral artery and common femoral vein was performed to restore venous patency and allow rescue dialysis access. At 3-year follow-up, the fistula remains widely patent with 2 L/min flow rates and no recurrent stenosis to the treated iliac vein. She has not required any further surgical or interventional radiological procedures to maintain fistula or central venous patency. Central venous stenosis or occlusion is common for patients requiring dialysis, especially those with multiple previous long-term central venous cannulations. If restriction of outflow is present, AVF may fail. Venous patch angioplasty in these cases is a successful technique, allowing AVF formation and long-term patency. Central venous stenosis can be treated successfully with patch venoplasty to accommodate AVF/AVG formation for rescue vascular access; this is a potentially lifesaving intervention for patients requiring dialysis. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Reconstruction of mandibular defects with autogenous bone grafts: a review of 30 cases

    International Nuclear Information System (INIS)

    Sajid, M.A.; Warraich, R.A.; Abid, H.; Haq, M.E.; Shah, K.L.; Khan, Z.

    2012-01-01

    Multitudes of options are available for reconstruction of functional and cosmetic defects of the mandible, caused by various ailments. At the present time, autogenous bone grafting is the gold standard by which all other techniques of reconstruction of the mandible can be judged. The purpose of this study was to evaluate the outcome of different osseous reconstruction options using autogenous bone grafts for mandibular reconstruction. Methods: This Interventional study was conducted at Department of Oral and Maxillofacial Surgery, King Edward Medical University/Mayo Hospital Lahore, from January 2008 to July 2009 including one year follow-up. The study was carried out on thirty patients having bony mandibular defects. They were reconstructed with the autogenous bone grafts from different graft donor sites. On post-operative visits they were evaluated for outcome variables. Results: Success rate of autogenous bone grafts in this study was 90%. Only 10% of the cases showed poor results regarding infection, resorption and graft failure. Conclusion: Autogenous bone grafts, non-vascularized or vascularized, are a reliable treatment modality for the reconstruction of the bony mandibular defects with predictable functional and aesthetic outcome. (author)

  17. Follow-up of in situ vein femoral-to-popliteal bypass grafts with intravenous digital subtraction angiography

    International Nuclear Information System (INIS)

    Hemingway, A.P.; Hartnell, G.G.; Smith, J.

    1986-01-01

    The detection of early strictures or occlusion of in situ vein (femoral to popliteal) grafts allows the possibility of surgical or radiological intervention to preserve graft function. Twenty patients have been followed up prospectively with intravenous digital subtraction angiography at 3-month intervals after surgery. Contrast medium is injected via a centrally placed catheter, and five over-lapping positions are examined using a 14-inch intensifier. An average total of 175-200 ml of contrast medium has been given. In all cases it has been possible to visualize the entire graft, the distal anastomoses, and the run-off. In four patients early stenoses have been diagnosed. Three have been treated by percutaneous transluminal angioplasty and one surgically, all with a successful outcome

  18. Interposition vein cuffs.

    Science.gov (United States)

    Harris, P; Da Silva, T; How, T

    1996-01-01

    A vein cuff interposed at the distal anastomosis between a prosthetic vascular graft and a recipient infrageniculate artery improves the chances of continued patency of the graft, at least in the short and medium term. The mode of effect appears to be suppression or modification of anastomotic myointimal hyperplasia (MIH). In the event of graft failure the recipient artery and run-off vessels remain free from MIH and their patency is preserved thereby improving the prospects for further vascular reconstruction and limb salvage. The mechanisms by which interposition vein cuffs might modulate MIH are reviewed. Experimental evidence is described to show that the geometry of a cuffed anastomosis promotes a characteristic haemodynamic flow structure with a stable vortex. It is suggested that this vortex exerts greater shear stress upon the wall of the artery than the normal laminar flow observed in conventional anastomoses. High shear stress is known to inhibit MIH.

  19. Resolution of Large Azygos Vein Aneurysm Following Stent-Graft Shunt Placement in a Patient with Ehlers-Danlos Syndrome Type IV

    International Nuclear Information System (INIS)

    D'Souza, Estelle S.; Williams, David M.; Deeb, G.M.; Cwikiel, Wojciech

    2006-01-01

    Ehlers-Danlos syndrome (EDS) type IV is a rare connective tissue disorder associated with thin-walled, friable arteries and veins predisposing patients to aneurysm formation, dissection, fistula formation, and vessel rupture. Azygos vein aneurysm is an extremely rare condition which has not been reported in association with EDS in the literature. We present a patient with EDS type IV and interrupted inferior vena cava (IVC) with azygos continuation who developed an azygos vein aneurysm. In order to decrease flow through the azygos vein and reduce the risk of aneurysm rupture, a stent-graft shunt was created from the right hepatic vein to the azygos vein via a transhepatic, retroperitoneal route. At 6 month follow-up the shunt was open and the azygos vein aneurysm had resolved

  20. Full paleostress tensor reconstruction using quartz veins of Panasqueira Mine, central Portugal; part I: Paleopressure determination

    Science.gov (United States)

    Jaques, Luís; Pascal, Christophe

    2017-09-01

    Paleostress tensor restoration methods are traditionally limited to reconstructing geometrical parameters and are unable to resolve stress magnitudes. Based on previous studies we further developed a methodology to restore full paleostress tensors. We concentrated on inversion of Mode I fractures and acquired data in Panasqueira Mine, Portugal, where optimal exposures of mineralized quartz veins can be found. To carry out full paleostress restoration we needed to determine (1) pore (paleo)pressure and (2) vein attitudes. The present contribution focuses specifically on the determination of pore pressure. To these aims we conducted an extensive fluid inclusion study to derive fluid isochores from the quartz of the studied veins. To constrain P-T conditions, we combined these isochores with crystallisation temperatures derived from geochemical analyses of coeval arsenopyrite. We also applied the sphalerite geobarometer and considered two other independent pressure indicators. Our results point to pore pressures of ∼300 MPa and formation depths of ∼10 km. Such formation depths are in good agreement with the regional geological evolution. The obtained pore pressure will be merged with vein inversion results, in order to achieve full paleostress tensor restoration, in a forthcoming companion paper.

  1. Acromioclavicular joint reconstruction using a tendon graft: a biomechanical study comparing a novel “sutured throughout” tendon graft to a standard tendon graft

    Directory of Open Access Journals (Sweden)

    Naziri Qais

    2016-01-01

    Full Text Available Background: With a recurrence rate of over 30%, techniques that offer stronger acromioclavicular (AC joint reconstruction through increased graft strength may provide longevity. The purpose of our study was to determine the biomechanical strength of a novel tendon graft sutured throughout compared to a native tendon graft in Grade 3 anatomical AC joint reconstruction. Methods: For this in vitro experiment, nine paired (n = 18 embalmed cadaveric AC joints of three males and six females (age 86 years, range 51–94 years were harvested. Anatomic repair with fresh bovine Achilles tendon grafts without bone block was simulated. Specimens were divided into two groups; with group 1 using grafts with ultra-high molecular-weight polyethylene (UHMWPE suture ran throughout the entire length. In group 2, reconstruction with only native allografts was performed. The distal scapula and humerus were casted in epoxy compound and mounted on the mechanical testing machine. Tensile tests were performed using a mechanical testing machine at the rate of 50 mm/min. Maximum load and displacement to failure were collected. Results: The average load to failure was significantly higher for group 1 compared to group 2, with mean values of 437.5 N ± 160.7 N and 94.4 N ± 43.6 N, (p = 0.001. The average displacement to failure was not significantly different, with 29.7 mm ± 10.6 mm in group 1 and 25 mm ± 9.1 mm in group 2 (p = 0.25. Conclusion: We conclude that a UHMWPE suture reinforced graft can provide a 3.6 times stronger AC joint reconstruction compared to a native graft.

  2. Immediate breast reconstruction using autologous skin graft associated with breast implant.

    Science.gov (United States)

    Dutra, A K; Andrade, W P; Carvalho, S M T; Makdissi, F B A; Yoshimatsu, E K; Domingues, M C; Maciel, M S

    2012-02-01

    Immediate breast reconstruction with skin graft is still little mentioned in the literature. Follow-up studies regarding the technique aspects are particularly scarce. The objective was to detail immediate breast reconstruction using autologous skin graft. Patients (n = 49) who underwent mastectomies and autologous immediate breast reconstruction with skin graft associated with a breast implant at A. C. Camargo Hospital (São Paulo, Brazil) between January 2007 and July 2010 were included. Information on clinical data, technique details and clinical outcome were prospectively collected. Following mastectomy, the autologous full-thickness skin graft was obtained through an inframammary fold incision along the contralateral breast in most patients. The skin graft was placed on the surface of the pectoralis major muscle after adjustments to conform to the mastectomy defect. A minimum of 10-month follow-up period was established. Patients' age ranged from 35 to 55 years and all received a silicone gel textured surface implant to obtain the necessary breast mound. The mean surgical time was 45 min, and the mean amount of skin resection was 4.5 cm in the largest diameter. Follow-up ranged from 10 to 35 months (median 23). All patients had silicone-gel textured surface implants to perform the breast mound reconstruction. No complications were observed in 87.8% of reconstructions. Forty-six patients (94%) had no complaints about the donor-site aesthetics. The result was a breast mound with a central ellipse of healed skin graft. Three (6%) poor results were observed. Thirty-six patients (67%) reported the results as good or very good. Our results lead us to conclude that autologous skin graft provided a reliable option in immediate breast reconstruction to skin-sparing mastectomy defects. The technique accomplished a single-stage implant breast reconstruction when there is inadequate skin coverage. Copyright © 2011 British Association of Plastic, Reconstructive and

  3. Breast Reconstruction after a Bilateral Mastectomy Using the BRAVA Expansion System and Fat Grafting

    Directory of Open Access Journals (Sweden)

    Ondrej Mestak, MD

    2013-11-01

    Full Text Available Summary: Fat graft breast reconstruction following a mastectomy is always limited by the size of the skin envelope, which affects the amount of graft that can be injected in 1 session. Because the fat graft naturally resorbs in all patients, several sessions of fat grafting are necessary. BRAVA’s negative pressure causes a “reverse” expansion of the skin envelope, thus permitting more space for the fat graft. This allows decreasing number of required procedures for an adequate breast reconstruction. We operated on a 38-year-old patient 4 years after bilateral mastectomy without irradiation for breast cancer. Before the procedure, the patient was instructed to wear the BRAVA system for 12 hours daily for 2 months before the first session, at all times between the sessions and for 1 month following the last fat grafting session. We performed 3 fat grafting sessions, as planned. Altogether, we injected 840 cm3 of fat on the right side and 790 cm3 of fat on the left side. Four months after the last operation, the patient was very satisfied with her new breasts. The breasts were soft, with good sensation and a natural feel. Using the BRAVA external expansion system for the enhancement of fat grafting is a suitable technique for breast reconstruction after a mastectomy. This technique produces soft and natural feeling breasts in fewer operative sessions, with a minimal risk of complications. Patient compliance, however, is greatly needed to achieve the desired results.

  4. Knee extension and flexion muscle power after anterior cruciate ligament reconstruction with patellar tendon graft or hamstring tendons graft: a cross-sectional comparison 3 years post surgery

    DEFF Research Database (Denmark)

    Ageberg, Eva; Roos, Harald; Silbernagel, Karin

    2008-01-01

    Hamstring muscles play a major role in knee-joint stabilization after anterior cruciate ligament (ACL) injury. Weakness of the knee extensors after ACL reconstruction with patellar tendon (PT) graft, and in the knee flexors after reconstruction with hamstring tendons (HT) graft has been observed ...

  5. [Application of joint reconstruction with autogenous coronoid process graft to treat temporomandibular joint ankylosis].

    Science.gov (United States)

    Xie, Qing-tiao; Huang, Xuan-ping; Jiang, Xian-fang; Yang, Yuan-yuan; Li, Hua; Lin, Xi

    2013-08-01

    To evaluate the clinical effect of joint reconstruction by using autogenous coronoid process graft to treat temporomandibular joint(TMJ) ankylosis. Nine cases of TMJ ankylosis from September 2008 to September 2010 were surgically treated by joint reconstruction with autogenous coronoid process graft, using autogenous articular disc or prosthodontic membrane as interpositional material. Mouth opening, occlusion and cone beam CT(CBCT) were used for evaluation before and after surgery. Satisfactory mouth opening was achieved in all patients and no one got occlusal changes or reankylosis during follow-up. CBCT showed that coronoid process graft reached bone union with the ramus and turned to be round. It is effective to cure TMJ ankylosis through joint reconstruction with autogenous coronoid process graft.

  6. Reconstruction of circulation in the fingertip without vein repair in zone I replantation.

    Science.gov (United States)

    Zhang, Xu; Wen, Sumin; Wang, Baoshi; Wang, Qi; Li, Chenglin; Zhu, Hongwei

    2008-11-01

    In fingertip replantation, adequate venous drainage is important for success. As the level of amputation becomes more distal, anastomosis of veins becomes more technically difficult. External bleeding is a common solution to venous congestion, but the process is burdensome because of duration of bleeding for 3 or more days after surgery. We present a new technique for reconstructing circulation without vein anastomosis in zone I replantation and analyze the outcomes of this technique in terms of eliminating external bleeding and of a high survival rate of the replanted digits. Between 1997 and 2007, we performed 120 replantations in 112 patients (83 male and 29 female; mean age, 33 years; range, 3-54 years). All were zone I amputations, based on the Tamai classification. We surgically repaired both proper digital arteries, excluded the vein, and then ligated 1 of the arteries. Using this technique, circulation was restored. Included in the outcome evaluation were 91 digits in the 87 patients (mean age, 35 years; range, 14-54) who returned for outcome assessments 12 months after surgery. Of 120 digits replanted, 115 digits survived, corresponding to an overall success rate of 96%. No patients received alternative means to alleviate venous congestion, such as leeches or other means of external bleeding. Nearly all of the 87 patients (91 digits) were satisfied with the results of the replantations. Our technique reconstructs circulation without vein anastomosis in zone I replantation. This alternative to venous congestion involves a simple surgical procedure and straightforward postoperative care. Follow-up assessments of a series of 120 replantations show that the majority of zone I replantations led to satisfactory function. We therefore propose this technique as an effective method for zone I replantation. Therapeutic IV.

  7. Reconstruction of mandibular defects using nonvascularized autogenous bone graft in Nigerians

    Directory of Open Access Journals (Sweden)

    Kizito Chioma Ndukwe

    2014-01-01

    Full Text Available Objectives: The aim of this study is to evaluate the success rate and complications of mandibular reconstruction with nonvascularized bone graft in Ile-Ife, Nigeria. Patients and Methods: A total of 25 patients who underwent reconstruction of mandibular discontinuity defects between January 2003 and February 2012, at the Obafemi Awolowo University Teaching Hospitals Complex, Ile-Ife constituted the study sample. Relevant information was retrieved from the patients′ records. This information include patients′ demographics (age and sex as well as the type of mandibular defect, cause of the defect, type of mandibular resection done, source of the bone graft used, and the method of graft immobilization. Morbidity associated with the graft procedures were assessed by retrieving information on graft failures, length of hospital stay following surgery, rehabilitation device used and associated graft donor and recipient site complications. Result: There were 12 males and 13 females with a male:female ratio was 1:1.1. The age of the patients ranged from 13 to 73 years with a mean age for males 32.7 ± standard deviation (SD 12.9 and for females 35.0 ± SD 17.1. Jaw defect was caused by resection for tumours and other jaw pathologies in 92% of cases. Complete symphyseal involvement defect was the most common defect recorded 11 (44%. Reconstruction with nonvascularized rib graft accounted for 68% of cases while iliac crest graft was used in 32% of the patients. Successful take of the grafts was recorded in 22 patients while three cases failed. Wound dehiscence (two patients and postoperative wound infection (eight patients were the most common complications recorded. Conclusion: The use of nonvascularized graft is still relevant in the reconstruction of large mandibular defects caused by surgical ablation of benign conditions in Nigerians. Precise surgical planning and execution, extended antibiotic therapy, and meticulous postoperative care

  8. Acromioclavicular Reconstruction using Autogenous Semitendinosus Tendon Graft and the Importance of Postoperative Rehabilitation: A Case Report

    Directory of Open Access Journals (Sweden)

    Jade PY Ho

    2013-11-01

    Full Text Available We present a case of chronic acromioclavicular joint dislocation (Rockwood type 5 in which the choice of acromioclavicular reconstruction using autogenous semitendinosus tendon graft was made due to its superiority in anatomical reconstruction of the coracoclavicular ligaments, and the impact of postoperative rehabilitation on the recovery of this patient. We also discuss the rationale behind this.

  9. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: early results.

    Science.gov (United States)

    Hwang, Ho Young; Kim, Jun Sung; Oh, Se Jin; Kim, Ki-Bong

    2012-11-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft trial was designed to evaluate the saphenous vein compared with the right internal thoracic artery as a Y-composite graft anastomosed to the side of the left internal thoracic artery. In this early analysis, we compared early angiographic patency rates and clinical outcomes. From September 2008 to October 2011, 224 patients with multivessel coronary artery disease were randomized prospectively to undergo off-pump revascularization using the saphenous vein group (n = 112) or the right internal thoracic artery group (n = 112) as Y-composite grafts. Early postoperative (1.4 ± 1.1 days) angiographic patency and clinical outcomes were compared. There was 1 operative death in the right internal thoracic artery group. No statistically significant differences in postoperative morbidities, including atrial fibrillation and acute renal failure, were observed between the groups. The number of distal anastomoses using the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 2.3 ± 0.8 and 1.9 ± 0.7 in the saphenous vein and right internal thoracic artery groups, respectively (P < .001). A third conduit was used in 44 patients (saphenous vein group vs right internal thoracic artery group, 4/109 vs 40/110; P < .001) to extend the side-arm Y-composite graft for complete revascularization. Early angiography demonstrated an overall patency rate of 99.4% (771 of 776 distal anastomoses). Patency rates of the side-arm Y-composite graft (saphenous vein vs right internal thoracic artery) were 98.8% (245 of 248) and 99.5% (207 of 208) in the saphenous vein and right internal thoracic artery groups, respectively (P = .629). A third conduit was needed to extend the right internal thoracic artery composite graft and reach the target vessels in 36.4% (40/110) of the patients. The saphenous vein composite graft was comparable with the right internal thoracic artery composite graft

  10. Hemodynamic effects of spiral ePTFE prosthesis compared with standard arteriovenous graft in a carotid to jugular vein porcine model.

    Science.gov (United States)

    Jahrome, Ommid K; Hoefer, Imo; Houston, Graeme J; Stonebridge, Peter A; Blankestijn, Peter J; Moll, Frans L; de Borst, Gert J

    2011-01-01

    The primary patency rate of arteriovenous (AV) grafts is limited by distal venous anastomosis stenosis or occlusion due to intimal hyperplasia associated with distal graft turbulence. The normal blood flow in native arteries is spiral laminar flow. Standard vascular grafts do not produce spiral laminar flow at the distal anastomosis. Vascular grafts which induce a spiral laminar flow distally result in lower turbulence, particularly near the vessel wall. This initial study compares the hemodynamic effects of a spiral flow-inducing graft and a standard graft in a new AV carotid to jugular vein crossover graft porcine model. Four spiral flow grafts and 4 control grafts were implanted from the carotid artery to the contralateral jugular vein in 4 pigs. Two animals were terminated after 48 hours and 2 at 14 days. Graft patency was assessed by selective catheter digital angiography, and the flow pattern was assessed by intraoperative flow probe and color Doppler ultrasound (CDU) measurements. The spiral grafts were also assessed at enhanced flow rates using an external roller pump to simulate increased flow rates that may occur during dialysis using a standard dialysis needle cannulation. The method increased the flow rate through the graft by 660 ml/min. The graft distal anastomotic appearances were evaluated by explant histopathology. All grafts were patent at explantation with no complications. All anastomoses were found to be wide open and showed no significant angiographic stenosis at the distal anastomosis in both spiral and control grafts. CDU examinations showed a spiral flow pattern in the spiral graft and double helix pattern in the control graft. No gross histopathological effects were seen in either spiral or control grafts. This porcine model is robust and allows hemodynamic flow assessment up to 14 days postimplantation. The spiral flow-inducing grafts produced and maintained spiral flow at baseline and enhanced flow rates during dialysis needle

  11. Press-fit Femoral Fixation in ACL Reconstruction using Bone-Patellar Tendon-Bone Graft

    Directory of Open Access Journals (Sweden)

    Kaseb Mohammad Hasan

    2009-05-01

    Full Text Available Bone-patellar tendon auto graft is probably the most widely used graft for ACL reconstruction. Several methods for graft fixation have been described. To avoid intra-articular hardware we adopt biological fixation with a femoral trapezoidal press-fit fixation. A prospective study was performed on 30 consecutive active people who underwent ACL reconstruction with this technique by two surgeons between september2004 and march2007 (mean follow-up 15.2 months. Results were evaluated by an independent examiner using radiography, subjective and objective evaluation. Assessment using the IKDC knee scoring revealed 92% of the patients with a normal or nearly normal knee joint. Lysholm's score was 63.6(40- 86 preoperatively and 91.88(73-100 at the latest follow up (P < 0.005. No patient complained of instability at latest follow up. The quadriceps muscle showed mild atrophy at 3 and 6 months and at final follow-up. Five Patients complained of anterior knee pain and had a positive kneeling test. We found no graft displacement on follow up radiographs. All cases showed radiological evidence of graft osteointegration at last follow up. Our results show that press-fit fixation of trapezoidal bone graft in femoral tunnel is a simple, reliable, and cost-effective alternative for ACL recon-struction using bone-patellar tendon-bone graft.

  12. Sequential Vein Bypass Grafting is Not Associated with an Increase of Either In-hospital or Mid-term Adverse Events in Off-pump Coronary Artery Bypass Grafting

    Directory of Open Access Journals (Sweden)

    Fucheng Xiao

    2015-01-01

    Full Text Available Background: The impact of sequential vein bypass grafting on clinical outcomes is less known in off-pump coronary artery bypass grafting (CABG. We aimed to evaluate the effects of sequential vein bypass grafting on clinical outcomes in off-pump CABG. Methods: From October 2009 to September 2013 at the Fuwai Hospital, 127 patients with at least one sequential venous graft were matched with 127 patients of individual venous grafts only, using propensity score matching method to obtain risk-adjusted outcome comparison. In-hospital measurement was composite outcome of in-hospital death, myocardial infarction (MI, stroke, requirement for intra-aortic ballon pump (IABP assistance and prolonged ventilation. Major adverse cardiac events (MACEs: Death, MI or repeat revascularization and angina recurrence were considered as mid-term endpoints. Results: No significant difference was observed among the groups in baseline characteristics. Intraoperative mean blood flow per vein graft was 40.4 ml in individual venous grafts groups versus 59.5 ml in sequential venous grafts groups (P < 0.001. There were no differences between individual and sequential venous grafts groups with regard to composite outcome of in-hospital mortality, MI, stroke, IABP assistance and prolonged ventilation (11.0% vs. 14.2%, P = 0.45. Individual in-hospital measurement also did not differ significantly between the two groups. At about four years follow-up, the survival estimates free from MACEs (92.5% vs. 97.3%, P = 0.36 and survival rates free of angina recurrence (80.9% vs. 85.5%, P = 0.48 were similar among individual and sequential venous grafts groups with a mean follow-up of 22.5 months. In the Cox regression analysis, sequential vein bypass grafting was not identified as an independent predictor of both MACEs and angina recurrence. Conclusions: Compared to individual vein bypass grafting, sequential vein bypass grafting was not associated with an increase of either in

  13. The accuracy of MRI in assessing graft integrity after anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Nakayama, Yoshihito; Shirai, Yasumasa; Narita, Tetsuya; Mori, Atsushi; Kobayashi, Kaoru

    2001-01-01

    To evaluate the efficacy of MRI in assessing anterior cruciate ligament (ACL) reconstruction graft integrity, we compared MRI findings with arthroscopic findings in 52 patients who had undergone arthroscopically assisted ACL reconstruction using semitendinosus and gracilis tendons augmented by woven polyester. MRI and arthroscopy were carried out 12 months after the operation. The MR appearance of ACL grafts was categorized into 3 types by signal intensity and continuity of the ligament according to Rak's method: well-defined type: the graft was visualized as a smoothly continuous band with low signal over the entire course; intermediate type: signal intensity increased and a low-signal band was visualized only in part of the graft; indiscernible type: the graft was not identified through the joint cavity due to markedly increased signal intensity. When the MR appearance of intermediate or indiscernible types was defined as torn, the grafts were presumed to be torn in 9 patients whose arthroscopic findings were 7 intact and 2 torn grafts. All cases with intact MRI findings were intact on arthroscopic examination. Thus, the sensitivity, specificity and accuracy of MRI as an evaluative tool for ACL graft tears were 100%, 86% and 86.5%, respectively. (author)

  14. Angiographic predictors of 3-year patency of bypass grafts implanted on the right coronary artery system: a prospective randomized comparison of gastroepiploic artery, saphenous vein, and right internal thoracic artery grafts.

    Science.gov (United States)

    Glineur, David; D'hoore, William; de Kerchove, Laurent; Noirhomme, Philippe; Price, Joel; Hanet, Claude; El Khoury, Gebrine

    2011-11-01

    Saphenous vein, in situ right gastroepiploic artery, and right internal thoracic artery grafts are routinely used to revascularize the right coronary artery. Little is known about the predictive value of objective preoperative angiographic parameters on midterm graft patency. We prospectively enrolled 210 consecutive patients undergoing coronary revascularization. Revascularization of the right coronary artery was randomly performed with the saphenous vein grafts in 81 patients and the right gastroepiploic artery in 92 patients. During the same study period, 37 patients received right coronary artery revascularization with the right internal thoracic artery used in a Y-composite fashion. All patients underwent a protocol-driven coronary angiogram 3 years after surgery. Preoperative angiographic parameters included minimum lumen diameter percent stenosis measured by quantitative angiography. A graft was considered "not functional" with patency scores of 0 to 2 and "functional" with patency scores of 3 or 4. Angiographic follow-up was 100% complete. A significant difference in the distribution of flow patterns was observed in the 3 groups. In multivariate analysis, the use of a saphenous vein graft was associated with superior graft functionality compared with the other conduits (odds ratio, 6.1; 95% confidence interval, 2.4-15). Graft function was negatively influenced by the minimum lumen diameter (odds ratio, 0.11; confidence interval, 0.05-0.25). In the right gastroepiploic artery and right internal thoracic artery groups, the proportion of functional grafts was higher when the minimum lumen diameter was below a threshold value in the third minimum lumen diameter quartile (0.64-1.30 mm). Preoperative angiography predicts graft patency in the right gastroepiploic artery and right internal thoracic artery, whereas the flow pattern in saphenous vein grafts is significantly less influenced by quantitative angiographic parameters. Copyright © 2011 The American

  15. Efficacy of duplex ultrasound surveillance after infrainguinal vein bypass may be enhanced by identification of characteristics predictive of graft stenosis development.

    Science.gov (United States)

    Tinder, Chelsey N; Chavanpun, Joe P; Bandyk, Dennis F; Armstrong, Paul A; Back, Martin R; Johnson, Brad L; Shames, Murray L

    2008-09-01

    Controversy regarding the efficacy of duplex ultrasound surveillance after infrainguinal vein bypass led to an analysis of patient and bypass graft characteristics predictive for development of graft stenosis and a decision of secondary intervention. Retrospective analysis of a contemporary, consecutive series of 353 clinically successful infrainguinal vein bypasses performed in 329 patients for critical (n = 284; 80%) or noncritical (n = 69; 20%) limb ischemia enrolled in a surveillance program to identify and repair duplex-detected graft stenosis. Variables correlated with graft stenosis and bypass repair included: procedure indication, conduit type (saphenous vs nonsaphenous vein; reversed vs nonreversed orientation), prior bypass graft failure, postoperative ankle-brachial index (ABI) < 0.85, and interpretation of the first duplex surveillance study as "normal" or "abnormal" based on peak systolic velocity (PSV) and velocity ratio (Vr) criteria. Overall, 126 (36%) of the 353 infrainguinal bypasses had 174 secondary interventions (endovascular, 100; surgery, 74) based on duplex surveillance; resulting in 3-year Kaplan-Meier primary (46%), assisted-primary (80%), and secondary (81%) patency rates. Characteristics predictive of duplex-detected stenosis leading to intervention (PSV: 443 +/- 94 cm/s; Vr: 8.6 +/- 9) were: "abnormal" initial duplex testing indicating moderate (PSV: 180-300 cm/s, Vr: 2-3.5) stenosis (P < .0001), non-single segment saphenous vein conduit (P < .01), warfarin drug therapy (P < .01), and redo bypass grafting (P < .001). Procedure indication, postoperative ABI level, statin drug therapy, and vein conduit orientation were not predictive of graft revision. The natural history of 141 (40%) bypasses with an abnormal first duplex scan differed from "normal" grafts by more frequent (51% vs 24%, P < .001) and earlier (7 months vs 11 months) graft revision for severe stenosis and a lower 3-year assisted primary patency (68% vs 87%; P < .001). In 52

  16. Comparative Evaluation of Chitosan Nerve Guides with Regular or Increased Bendability for Acute and Delayed Peripheral Nerve Repair: A Comprehensive Comparison with Autologous Nerve Grafts and Muscle-in-Vein Grafts.

    Science.gov (United States)

    Stößel, Maria; Wildhagen, Vivien M; Helmecke, Olaf; Metzen, Jennifer; Pfund, Charlotte B; Freier, Thomas; Haastert-Talini, Kirsten

    2018-05-08

    Reconstruction of joint-crossing digital nerves requires the application of nerve guides with a much higher flexibility than used for peripheral nerve repair along larger bones. Nevertheless, collapse-resistance should be preserved to avoid secondary damage to the regrowing nerve tissue. In recent years, we presented chitosan nerve guides (CNGs) to be highly supportive for the regeneration of critical gap length peripheral nerve defects in the rat. Now, we evidently increased the bendability of regular CNGs (regCNGs) by developing a wavy wall structure, that is, corrugated CNGs (corrCNGs). In a comprehensive in vivo study, we compared both types of CNGs with clinical gold standard autologous nerve grafts (ANGs) and muscle-in-vein grafts (MVGs) that have recently been highlighted in the literature as a suitable alternative to ANGs. We reconstructed rat sciatic nerves over a critical gap length of 15 mm either immediately upon transection or after a delay period of 45 days. Electrodiagnostic measurements were applied to monitor functional motor recovery at 60, 90, 120, and 150 (only delayed repair) days postreconstruction. Upon explanation, tube properties were analyzed. Furthermore, distal nerve ends were evaluated using histomorphometry, while connective tissue specimens were subjected to immunohistological stainings. After 120 days (acute repair) or 150 days (delayed repair), respectively, compression-stability of regCNGs was slightly increased while it remained stable in corrCNGs. In both substudies, regCNGs and corrCNGs supported functional recovery of distal plantar muscles in a similar way and to a greater extent when compared with MVGs, while ANGs demonstrated the best support of regeneration. Anat Rec, 2018. © 2018 Wiley Periodicals, Inc. © 2018 Wiley Periodicals, Inc.

  17. Transportal anterior cruciate ligament reconstruction with quadrupled hamstring tendon graft: A prospective outcome study

    Directory of Open Access Journals (Sweden)

    Chandan Kumar

    2017-01-01

    Full Text Available Background: Anterior cruciate ligament (ACL reconstruction has been one of the most commonly performed procedures throughout the world. Unsatisfactory outcome with conventional ACL reconstruction has been attributed to nonanatomic graft placement. Researchers have advised placing the graft in the native footprint of ACL to avoid nonanatomic graft placement. The goal of this study was to analyze the outcome of anatomic single bundle ACL reconstruction using transportal technique. Materials and Methods: This was a prospective outcome study conducted on 85 consecutive patients of ACL reconstruction of which 62 patients met inclusion and exclusion criteria and were analyzed for final results. All the patients underwent ACL reconstruction by quadrupled hamstring tendon graft using transportal technique and the accessory anteromedial (AAM portal for femoral tunnel creation. The graft was fixed with endobutton on femoral side and bioabsorbable screw on the tibial side. Patients were evaluated for range of motion, International Knee Documentation Committee (IKDC score, and Lysholm scores at a minimum followup period of 2 years. The mean pre- and postoperative scores were compared using Wilcoxon signed-rank test. Results: The mean Lysholm and IKDC scores improved significantly (P < 0.0001 from preoperative value. According to IKDC score, 90.3% (n = 56 were either normal or near normal at final followup. According to Lysholm score, 75.8% of patients had excellent and 13.3% had good results. Preoperatively, pivot shift was present in 85.5% (n = 53 of patients which reduced to 4.8% (n = 3 postoperatively. Infection and knee stiffness occurred in two patients, and femoral tunnel blowout and graft re-rupture occurred in one patient each. Conclusion: Anatomic ACL reconstruction by AAM portal is a reproducible technique which gives good clinical outcome at short-term followup.

  18. Chest wall reconstruction with autologas rib grafts in dogs and report of a clinic case.

    Science.gov (United States)

    Tunçözgür, B; Elbeyli, L; Güngör, A; Işik, F; Akay, H

    1999-09-01

    Nowadays, in chest wall reconstruction prosthetic materials are generally used. However, the rejections of prosthetic materials and infections frequently occur in chest wall reconstruction, especially after radiotherapy or resection that is performed due to infections. We used 10 mongrel dogs and performed resections of 8 cm diameter on their chest walls. In the reconstruction of these defects, in five of the subjects, we used two free rib grafts with periosteum to be resected from the contralateral side and in other five subjects, we used free rib grafts without periosteum. After this experimental study, sternal resection was performed in a 24-year-old man because of sternal osteomyelitis. First to obtain rib grafts with periosteum, partial resection was performed to 5th, 7th, and 9th ribs of the lateral left side. After, total sternal resection, end to end anastomosis was performed to the 2nd, 3rd, 4th and 5th anterior ends of the ribs. Autogeneous rib grafts were found to be enough to provide chest wall stabilization. The contralateral autogeneous free rib grafts can successfully be used in reconstruction of wide chest wall defects. This method is found to be effective and sufficient to prevent infection, rejection and to provide stabilization.

  19. Reconstruction of the Upper Eyelid with Flaps and Free Grafts after Excision of Basal Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    Alessandro Guido Actis

    2011-11-01

    Full Text Available Purpose: To describe a reconstructive technique of the superior eyelid with flaps and free grafts after excision of a basal cell carcinoma. Methods: Single case report of a 79-year-old woman who presented to our hospital with a basal cell carcinoma of the upper eyelid margin with initial erosion. Results: A large and full-thickness excision of the carcinoma was performed. The reconstruction technique should be customized to the individual patient. In this case, the use of a full-thickness tarsal graft from the contralateral upper eyelid, followed by an ipsilateral bipedicled flap and finally by a skin graft, was an effective surgical procedure, performed in one stage, without complications, and with good functional and esthetic results. Conclusions: Malignant neoplasms represent the leading cause of plastic reconstruction in the orbital region. Surgical techniques must be individualized for each patient and for each type of carcinoma. Reconstructive techniques with free grafts and flaps yield excellent results in the orbital region, particularly when some advice and a few fundamental rules are followed, namely accurate hemostasis of the receiving graft bed by moderate use of diathermy, careful suturing of the edges, and application of a compressive dressing for at least 4 days. Postoperative complications are very rare.

  20. Fingertip reconstruction with simultaneous flaps and nail bed grafts following amputation.

    Science.gov (United States)

    Hwang, Euna; Park, Byung Ho; Song, Seung Yong; Jung, Ho Sung; Kim, Chung Hun

    2013-07-01

    To report our technique and results with treating fingertip amputations with flaps and simultaneous nailbed grafts. We reconstructed 20 fingertip amputations with loss of bone and nail with flaps combined with nailbed grafts. We reconstructed the volar side of the fingertip with a flap, and the dorsal side of the fingertip with a nailbed grafted to the raw inner surface of the flap. We employed volar V-Y advancement flaps for transverse or dorsal oblique fingertip injuries and generally used abdominal flaps for volar oblique fingertip injuries. We harvested nailbeds from the amputated finger or from the patient's first toe. The length of the amputated fingertips was restored with the flaps, and the lost nailbeds were restored to their natural appearance with the nailbed grafts. We classified the results according to the length of the reconstructed fingertip and the appearance of the nail. Excellent or good results were achieved in 16 cases. Three cases had fair results and 1 had a poor result. We observed favorable results for distal fingertip amputations (Allen type II or III). In particular, most cases that were reconstructed with volar V-Y advancement flaps combined with nailbed grafts demonstrated favorable results. This method is useful for the restoration of dorsal oblique or transverse type fingertip amputations and is a good alternative when replantation is not an option. Copyright © 2013 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  1. Fat grafting and breast reconstruction: tips for ensuring predictability.

    Science.gov (United States)

    Gabriel, Allen; Champaneria, Manish C; Maxwell, G Patrick

    2015-06-01

    Autologous fat grafting is widely used in breast surgery to refine and optimize aesthetic outcomes. Despite its widespread use, obtaining predictable, reliable, and consistent outcomes remains a significant challenge and is influenced by the technique used for procurement, processing, and placement of the fat. At present, there is no published consensus on the optimal technique. The purpose of this article is to review current techniques at each stage of fat grafting and provide tips on best practices based on the published literature as well as our extensive clinical experience.

  2. Skin and Composite Grafting Techniques in Facial Reconstruction for Skin Cancer.

    Science.gov (United States)

    Brenner, Michael J; Moyer, Jeffrey S

    2017-08-01

    Skin and composite grafting provide effective resurfacing and reconstruction for cutaneous defects after excision of the malignancy. The goal is to restore a natural appearance and function while preventing distortion of the eyelid, nose, or lips. With careful planning and attention to aesthetic subunits, the surgeon can camouflage incisions and avoid blunting aesthetically sensitive sulci. The surgical plan is also informed by the pathology, as basal or squamous cell carcinomas removed by Mohs micrographic excision have different prognostic and logistical considerations from melanoma. Skin and composite grafting are useful as stand-alone procedures or may complement local flaps and other soft tissue reconstructions. Copyright © 2017 Elsevier Inc. All rights reserved.

  3. Multidetector CT angiography as a noninvasive tool to assess graft patency of surgically reconstructed diffusely diseased coronary arteries

    Directory of Open Access Journals (Sweden)

    Ahmed I. Rezk

    2014-03-01

    Conclusion: Extensive reconstruction of the diffusely diseased LAD using an ITA graft could be performed safely with very encouraging results. MDCT angiography is an excellent non invasive tool not only to evaluate graft patency in the reconstructed LAD but also to detect other findings in asymptomatic patients with diffuse coronary artery disease for better and more close follow up.

  4. The use of hamstring tendon graft for the anterior cruciate ligament reconstruction (benefi ts, problems and their solutions

    Directory of Open Access Journals (Sweden)

    V. V. Slastinin

    2017-01-01

    Full Text Available The search for optimal graft for anterior cruciate ligament reconstruction is going on. The donor site morbidity remains one of the major problems when using autografts. The article provides an overview of the advantages and disadvantages of using the hamstring tendon autografts for anterior cruciate ligament reconstruction, and the ways of solving the problems associated with using such types of grafts.

  5. Cartilage Morphological and Histological Findings After Reconstruction of the Glenoid With an Iliac Crest Bone Graft.

    Science.gov (United States)

    Auffarth, Alexander; Resch, Herbert; Matis, Nicholas; Hudelmaier, Martin; Wirth, Wolfgang; Forstner, Rosemarie; Neureiter, Daniel; Traweger, Andreas; Moroder, Philipp

    2018-04-01

    The J-bone graft is presumably representative of iliac crest bone grafts in general and allows anatomic glenoid reconstruction in cases of bone defects due to recurrent traumatic anterior shoulder dislocations. As a side effect, these grafts have been observed to be covered by some soft, cartilage-like tissue when arthroscopy has been indicated after such procedures. To evaluate the soft tissue covering of J-bone grafts by use of magnetic resonance imaging (MRI) and histological analysis. Case series; Level of evidence, 4. Patients underwent MRI at 1 year after the J-bone graft procedures. Radiological data were digitally processed and evaluated by segmentation of axial images. Independent from the MRI analysis, 2 biopsy specimens of J-bone grafts were harvested for descriptive histological analysis. Segmentation of the images revealed that all grafts were covered by soft tissue. This layer had an average thickness of 0.87 mm compared with 1.96 mm at the adjacent native glenoid. Of the 2 biopsy specimens, one exhibited evident hyaline-like cartilage and the other presented patches of chondrocytes embedded in a glycosaminoglycan-rich extracellular matrix. J-bone grafts are covered by soft tissue that can differentiate into fibrous and potentially hyaline cartilage. This feature may prove beneficial for delaying the onset of dislocation arthropathy of the shoulder.

  6. Reconstruction of the maxilla following hemimaxillectomy defects with scapular tip grafts and dental implants.

    Science.gov (United States)

    Mertens, Christian; Freudlsperger, Christian; Bodem, Jens; Engel, Michael; Hoffmann, Jürgen; Freier, Kolja

    2016-11-01

    Treatment of post-resective defects of the maxilla can be challenging and usually requires dental obturation or microvascular reconstruction. As compared to soft-tissue microvascular grafts, bone reconstruction can additionally allow for facial support and retention of dental implants. The aim of this study was to evaluate scapular tip grafts with respect to their applicability for maxillary reconstruction and their potential to retain dental implants for later dental rehabilitation. In this retrospective study, 14 patients with hemimaxillectomy defects were reconstructed with free scapular tip grafts, oriented horizontally, to rebuild the palate and alveolar ridge. After bone healing, three-dimensional virtual implant planning was performed, and a radiographic guide was fabricated to enable implant placement in the optimal anatomic and prosthetic position. All patients' mastication and speech were evaluated, along with the extent of defect closure, suitability of the graft sites for implant placement, and soft-tissue stability. Pre- and postsurgical radiographs were also evaluated. A good postoperative outcome was achieved in all patients, with complete closure of maxillary defects that were class II, according to the system of Brown and Shaw. Additional bone augmentation was necessary in two patients in order to increase vertical bone height. Patients were subsequently treated with 50 dental implants to retain dental prostheses. In all cases, additional soft-tissue surgery was necessary to achieve a long-term stable periimplant situation. No implants were lost during the mean observation period of 34 months. Due to its specific form, the scapular tip graft is well suited to reconstruct the palate and maxillary alveolar ridge and to enable subsequent implant-retained rehabilitation. Due to the limited bone volume, an accurate three-dimensional graft orientation is essential. Furthermore, most cases require additional soft-tissue surgery to achieve a long

  7. Outcomes and complications following graft reconstruction for anterior sternoclavicular joint instability.

    Science.gov (United States)

    Willinger, Lukas; Schanda, Jakob; Herbst, Elmar; Imhoff, Andreas B; Martetschläger, Frank

    2016-12-01

    Publications describing tendon graft reconstruction for anterior sternoclavicular joint (SCJ) instability are rare and usually refer to small patient numbers. The aim of this study was to systematically review the literature regarding outcomes and complications following tendon graft reconstruction techniques for anterior SCJ instability. An online database was systematically searched to identify studies on graft reconstruction for anterior SCJ instability. Reported outcome scores were graded as excellent, good, fair and poor to summarize the study results. All reported complications were recorded. Five articles with a total of 80 patients met the inclusion criteria. Reported outcomes were excellent in 10 %, good in 89 % and fair in 1 %. Recurrent instability was found in 10 % of the patients, and 5 % underwent revision surgery due to persistent impairment of shoulder function related to SCJ instability or osteoarthritis. Surgical stabilization techniques for the SCJ using autologous tendon grafts have shown to be safe and reliable and make better patients' pain situation and shoulder function. However, a certain amount of impairment might persist, which needs to be discussed with patients. Severe complications were rare and revision rates were as low as 5 %. Therefore, graft reconstruction techniques should be considered for patients with chronic anterior SCJ instability after a course of failed conservative treatment. This study is valuable for clinicians in daily clinical practice when dealing with this difficult-to-treat pathology and can help surgeons to better predict the clinical outcomes and complications following SCJ graft reconstruction. It should, however, not lead to underestimation of the potential risks of the procedure. Systematic review, Level IV.

  8. Alternatives to Autologous Bone Graft in Alveolar Cleft Reconstruction: The State of Alveolar Tissue Engineering.

    Science.gov (United States)

    Liang, Fan; Leland, Hyuma; Jedrzejewski, Breanna; Auslander, Allyn; Maniskas, Seija; Swanson, Jordan; Urata, Mark; Hammoudeh, Jeffrey; Magee, William

    2018-05-01

    Alveolar cleft reconstruction has historically relied on autologous iliac crest bone grafting (ICBG), but donor site morbidity, pain, and prolonged hospitalization have prompted the search for bone graft substitutes. The authors evaluated bone graft substitutes with the highest levels of evidence, and highlight the products that show promise in alveolar cleft repair and in maxillary augmentation. This comprehensive review guides the craniofacial surgeon toward safe and informed utilization of biomaterials in the alveolar cleft.A literature search was performed to identify in vitro human studies that fulfilled the following criteria: Level I or Level II of evidence, ≥30 subjects, and a direct comparison between a autologous bone graft and a bone graft substitute. A second literature search was performed that captured all studies, regardless of level of evidence, which evaluated bone graft substitutes for alveolar cleft repair or alveolar augmentation for dental implants. Adverse events for each of these products were tabulated as well.Sixteen studies featuring 6 bone graft substitutes: hydroxyapatite, demineralized bone matrix (DBM), β-tricalcium phosphate (TCP), calcium phosphate, recombinant human bone morphogenic protein-2 (rhBMP-2), and rhBMP7 fit the inclusion criteria for the first search. Through our second search, the authors found that DBM, TCP, rhBMP-2, and rhBMP7 have been studied most extensively in the alveolar cleft literature, though frequently in studies using less rigorous methodology (Level III evidence or below). rhBMP-2 was the best studied and showed comparable efficacy to ICBG in terms of volume of bone regeneration, bone density, and capacity to accommodate tooth eruption within the graft site. Pricing for products ranged from $290 to $3110 per 5 mL.The balance between innovation and safety is a complex process requiring constant vigilance and evaluation. Here, the authors profile several bone graft substitutes that demonstrate the most

  9. Using polypropylene mesh graft for soft-tissue reconstruction in internal hemipelvectomy: a case report

    Directory of Open Access Journals (Sweden)

    Asavamongkolkul Apichat

    2012-06-01

    Full Text Available Abstract We report the case of a patient with chondrosarcoma involving the right pelvis and contralateral pubic area in a 45-year-old male who underwent an extensive internal hemipelvectomy without bony reconstruction. We demonstrate the technique of using polypropylene mesh graft for soft-tissue reconstruction. Follow-up at 7.5 years showed a good oncological and functional outcome.

  10. Anterior Cranial Base Reconstruction with a Reverse Temporalis Muscle Flap and Calvarial Bone Graft

    Directory of Open Access Journals (Sweden)

    Seung Gee Kwon

    2012-07-01

    Full Text Available BackgroundCranial base defects are challenging to reconstruct without serious complications. Although free tissue transfer has been used widely and efficiently, it still has the limitation of requiring a long operation time along with the burden of microanastomosis and donor site morbidity. We propose using a reverse temporalis muscle flap and calvarial bone graft as an alternative option to a free flap for anterior cranial base reconstruction.MethodsBetween April 2009 and February 2012, cranial base reconstructions using an autologous calvarial split bone graft combined with a reverse temporalis muscle flap were performed in five patients. Medical records were retrospectively analyzed and postoperative computed tomography scans, magnetic resonance imaging, and angiography findings were examined to evaluate graft survival and flap viability.ResultsThe mean follow-up period was 11.8 months and the mean operation time for reconstruction was 8.4±3.36 hours. The defects involved the anterior cranial base, including the orbital roof and the frontal and ethmoidal sinus. All reconstructions were successful. Viable flap vascularity and bone survival were observed. There were no serious complications except for acceptable donor site depressions, which were easily corrected with minor procedures.ConclusionsThe reverse temporalis muscle flap could provide sufficient bulkiness to fill dead space and sufficient vascularity to endure infection. The calvarial bone graft provides a rigid framework, which is critical for maintaining the cranial base structure. Combined anterior cranial base reconstruction with a reverse temporalis muscle flap and calvarial bone graft could be a viable alternative to free tissue transfer.

  11. Microsurgical reconstruction of large nerve defects using autologous nerve grafts.

    Science.gov (United States)

    Daoutis, N K; Gerostathopoulos, N E; Efstathopoulos, D G; Misitizis, D P; Bouchlis, G N; Anagnostou, S K

    1994-01-01

    Between 1986 and 1993, 643 patients with peripheral nerve trauma were treated in our clinic. Primary neurorraphy was performed in 431 of these patients and nerve grafting in 212 patients. We present the functional results after nerve grafting in 93 patients with large nerve defects who were followed for more than 2 years. Evaluation of function was based on the Medical Research Council (MRC) classification for motor and sensory recovery. Factors affecting functional outcome, such as age of the patient, denervation time, length of the defect, and level of the injury were noted. Good results according to the MRC classification were obtained in the majority of cases, although function remained less than that of the uninjured side.

  12. miRNA-21 is dysregulated in response to vein grafting in multiple models and genetic ablation in mice attenuates neointima formation

    NARCIS (Netherlands)

    McDonald, Robert A; White, Katie M; Wu, Junxi; Cooley, Brian C; Robertson, Keith E; Halliday, Crawford A; McClure, John D; Francis, Sheila; Lu, Ruifaug; Kennedy, Simon; George, Sarah J; Wan, Song; van Rooij, Eva; Baker, Andrew H

    AIMS: The long-term failure of autologous saphenous vein bypass grafts due to neointimal thickening is a major clinical burden. Identifying novel strategies to prevent neointimal thickening is important. Thus, this study aimed to identify microRNAs (miRNAs) that are dysregulated during neointimal

  13. Comparison between the STENTYS self-apposing bare metal and paclitaxel-eluting coronary stents for the treatment of saphenous vein grafts (ADEPT trial)

    NARCIS (Netherlands)

    A.J.J. IJsselmuiden (Alexander); C. Simsek (Cihan); Van Driel, A.G. (A. G.); Bouchez, D. (D.); G. Amoroso (Giovanni); P. Vermeersch (Paul); Karjalainen, P.P. (P. P.)

    2018-01-01

    textabstractAims To describe the safety and performance of STENTYS self-expandable bare metal stents (BMS) versus paclitaxel-eluting stents (PES) in saphenous vein grafts (SVGs). Methods and Results A randomised controlled trial was performed in four hospitals in three European countries between

  14. Antiplatelet drug selection in PCI to vein grafts in patients with acute coronary syndrome and adverse clinical outcomes

    DEFF Research Database (Denmark)

    Sirker, Alex; Kwok, Chun Shing; Kontopantelis, Evangelos

    2018-01-01

    OBJECTIVE: This study aims to evaluate outcomes associated with different P2Y12 agents in Saphenous Vein graft (SVG) percutaneous coronary intervention (PCI). BACKGROUND: SVG PCI is associated with greater risks of ischemic complications, compared with native coronary PCI. Outcomes associated...... with the use of potent P2Y12 blocking drugs, Prasugrel and Ticagrelor, in SVG PCI are unknown. METHODS: Patients included in the study underwent SVG PCI in the United Kingdom between 2007 and 2014 for acute coronary syndrome and were grouped by P2Y12 antiplatelet use. In-hospital major adverse cardiac events....... CONCLUSIONS: Our real world national study provides no clear evidence to indicate that use of potent P2Y12 blockers in SVG PCI is associated with improved clinical outcomes....

  15. Knee stabiligy after ACL reconstruction through graft fixation in femoral tunnel: transfemoral pinning versus endobutton techniques

    Directory of Open Access Journals (Sweden)

    Tahmasebi MN

    2011-05-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: One of the most common orthopedic complaints is direct or indirect trauma to the knee with torn anterior cruciate ligament (ACL. Reconstruction of the torn ACL is emphatically offered in active individuals as by this operation, we prevent osteoarthritis, knee instability and injury to the meniscus. There are numerous methods for graft fixation in the femoral tunnel in ACL reconstruction. If the graft proves to be stable after the operation, patients would not complain of giving way knee joints. In this clinical trial, we compared transfemoral pinning with endobutton fixation of hamstring graft in arthroscopic ACL reconstruction by examining knee stability and use of other relevant functional tests. "n"nMethods : Fourteen Patients who had undergone arthroscopic ACL reconstruction in Shariati Hospital during the years 2008-2009 and were being followed up were evaluated at least 15 months post-operatively by physical examination and the use of an arthrometer made by the Faculty of Mechanics of Sharif Technical University."n"nResults : The results showed that two out of seven patients in which their ACL had been reconstructed by hamstring graft fixation by endobutton technique, and

  16. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    International Nuclear Information System (INIS)

    Bakhru, Prashant; Park, Brian; Umans, Hilary; DiFelice, Gregory S.; Tobin, Keith

    2011-01-01

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  17. MRI of broken bioabsorbable crosspin fixation in hamstring graft reconstruction of the anterior cruciate ligament

    Energy Technology Data Exchange (ETDEWEB)

    Bakhru, Prashant [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Park, Brian [Albert Einstein College of Medicine, Bronx, NY (United States); Umans, Hilary [Department of Radiology Jacobi Medical Center, Bronx, NY (United States); Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States); DiFelice, Gregory S. [Hospital for Special Surgery, New York, NY (United States); Tobin, Keith [Lenox Hill Radiology and Imaging Associates, P.C., New York, NY (United States)

    2011-06-15

    To report seven cases of broken bioabsorbable femoral crosspins identified by MRI in evaluation of hamstring grafts of the anterior cruciate ligament. Seven cases of broken bioabsorbable crosspins utilized in femoral fixation of ACL hamstring grafts were identified prospectively and retrospectively from our PACs database during a period from 9/1/08 to 8/31/09. All imaging was performed using 1.5 or 3.0 Tesla MRI and were evaluated for T2 signal within and surrounding the crosspin, osteolysis surrounding the fragments, displacement of fragments, and graft integrity. Time from surgery was also recorded. Seven cases of hamstring grafts with broken bioabsorbable crosspins were imaged 4 months to 3 years following grafting. There was osteolysis surrounding the crosspin in all but one case in which the graft was intact but a pin fragment was displaced into the joint. One graft failed due to aseptic foreign-body reaction to the fixation with aggressive osteolysis at 9 months post surgery. In the remaining five, the ACL graft was either completely torn, partially torn, lax, or degenerative and frayed. Of these, the crosspins were broken and angulated with osteolysis surrounding the apex of the angulated fragment or demonstrated lateral extrusion of the peripheral fragment. Bioabsorbable crosspins utilized in femoral fixation of hamstring graft reconstruction of the ACL may become fractured. While the natural history of osteo-integration of these devices as demonstrated by MRI has not been defined, osteolysis surrounding the fragments, extrusion or displacement of the fragments, and graft laxity or failure would suggest that these are abnormal findings that should be reported. (orig.)

  18. Reconstruction of large upper eyelid defects with a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft.

    Science.gov (United States)

    Toft, Peter B

    2016-01-01

    To review and present the results of a one-step method employing a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft for reconstruction of large upper eyelid defects after tumour surgery. This was a retrospective case-series of 8 patients who underwent reconstruction of the upper eyelid after tumour removal. The horizontal defect involved 50-75% of the lid (3 pts.), more than 75% (3 pts.), and more than 75% plus the lateral canthus (2 pts.). The posterior lamella was reconstructed with contralateral upper eyelid tarsal plate. The anterior lamella was reconstructed with a laterally based myocutaneous pedicle flap in 7 patients, leaving a raw surface under the brow which was covered with a free skin graft. In 1 patient with little skin left under the brow, the anterior lamella was reconstructed with a bi-pedicle orbicularis muscle flap together with a free skin graft. All patients healed without necrosis, did not suffer from lagophthalmos, achieved reasonable cosmesis, and did not need lubricants. In one patient, a contact lens was necessary for three weeks because of corneal erosion. One patient still needs a contact lens 3 months after excision to avoid eye discomfort. Large upper eyelid defects can be reconstructed with a free tarsal plate graft and a laterally based myocutaneous pedicle flap in combination with a free skin graft. Two-step procedures can probably be avoided in most cases.

  19. Onlay Rib Bone Graft in Elevation of Reconstructed Auricle: 17 Years of Experience

    Directory of Open Access Journals (Sweden)

    Taehoon Kim

    2013-05-01

    Full Text Available BackgroundA cartilage wedge block and covering flap are standard procedures for firm elevation of the ear in microtia correction. However, using costal cartilage for elevation of the reconstructed auricle can be insufficient, and the fixed cartilage wedge block may be absorbed or may slip out. Furthermore, elevating covering flaps is time-consuming and uses up fascia, a potential source of reconstruction material. Therefore, we propose an innovative method using autologous onlay rib bone graft for auricular elevation of microtia.MethodsFrom February 1995 to August 2012, 77 patients received a first stage operation with a rib cartilage framework graft. In the second stage operation, a small full thickness of rib bone was harvested through the previous donor scar. The bihalved rib bone was inserted into the subperiosteal pocket beneath the cartilage framework.ResultsThe follow-up time ranged from 1 month to 17 years, with a mean of 3 years. All of the patients sustained the elevation of their ears very well during the follow-up period. Donor site problems, except for hypertrophic scars, were not observed. Surgery-related complications, specifically skin necrosis, infection, or hematoma, occurred in 4 cases.ConclusionsOnlay rib bone graft used to elevate the reconstructed auricle is a more anatomically appropriate material than cartilage, due to the bone-to-bone contact between the bone graft and the temporal bone. Postoperative minor correction of the elevation degree is straightforward and the skin graft survives better. Therefore, reconstructed auricle elevation using onlay rib bone graft is a useful and valuable method.

  20. Oral mucosa grafts for urethral reconstruction | Mungadi | Annals of ...

    African Journals Online (AJOL)

    Background: Urethral reconstruction has continued to present formidable and enormous challenges for urologic, paediatric and plastic surgeons as diverse opinions have been expressed on the quality and type of ideal substitution material. This literature review is aimed at drawing attention of surgeons to the versatile ...

  1. Comment on Article 'Split Calvarial Bone Graft for the Reconstruction ...

    African Journals Online (AJOL)

    and materials introduced in the 'market',[1,2] many surgeons need to review the advantages of the 'natural' ... numerous researches in the field of craniofacial reconstruction, the final results and conclusions are ... accompanied with bright advertisements, which can be misleading in cases where the knowledge of the subject.

  2. [Clinical study of full-thickness skin graft for reconstruction of completely defect nail unit].

    Science.gov (United States)

    Li, Wen-jun; Li, Chun; Zhu, Jin; Tian, Guang-lei; Chen, Shan-lin; Tian, Wen

    2012-12-18

    To explore a reconstruction method for complete nail bed defect caused by various kinds of reasons and to retrospectively analyze the effect of application of free full-thickness skin graft for the whole nail unit repair. Between Apr. 2010 and Mar. 2012, the method of free full-thickness skin graft was done for reconstruction of the completely nail unit defect in seven cases. There were 2 male and 5 female patients; the mean age of these patients at the time of surgery was 51.9 years (range: 7 to 70 years). The preoperative diagnoses included two cases of malignant melanoma, one of chronic infection, one of squamous cell carcinoma, two of subungual pigmentation and one of junctional nevus. There were 2 thumb lesions, 3 middle and 2 index finger lesions. Nail unit defect was in the range of 1.5 cm×2 cm to 2.5 cm × 3.5 cm and full thickness skin graft was harvested from the same medial side of upper arm (3 cases), forearm cubital fossa (1 case) and contralateral side of groin region (3 cases). All the patients were followed with an average follow-up time being 10 months. All the free skin graft taken was achieved with 100% in all the 7 cases, even in those patients whose partial cortical bone had been curetted. The skin graft was often bluish initially, and superficial blisters were always noticed within 1.5 months postoperatively and the survival skin graft was smooth eventually, and skin graft was adhered to the underlying bone tightly. There was no epidermal inclusion cyst and no residual nail formation. The skin donor sites were without complications. Aesthetic appearance was assessed by the surgeons and found no unacceptable for their patients. And all the patients were satisfied with the cosmetic appearance and active range of motion of their involved fingers, who did not express a desire to undergo any further of nail reconstruction. Free full-thickness skin grafting for reconstruction of the complete nail unit defect is a simple, safe and effective

  3. Reconstruction of a total avulsion of the hepatic veins and the suprahepatic inferior vena cava secondary to blunt thoracoabdominal trauma.

    Science.gov (United States)

    Kaemmerer, Daniel; Daffner, Wolfgang; Niwa, Martin; Kuntze, Thomas; Hommann, Merten

    2011-02-01

    Blunt injury to the inferior vena cava is a rare but dramatic event having a high mortality up to 80%. The mortality increases after total avulsion especially in combination with secondary intra-abdominal injuries. We report on a 15-year-old boy who sustained a blunt trauma with a total, partially covered avulsion of the hepatic veins and the suprahepatic inferior vena cava. We treated the patient under internal bypassing of the retrohepatic vena cava by using the heart-lung machine and reconstructed the hepatic veins and suprahepatic vena cava with a conduit made of pericard.

  4. In Situ Splitting of a Rib Bone Graft for Reconstruction of Orbital Floor and Medial Wall.

    Science.gov (United States)

    Uemura, Tetsuji; Yanai, Tetsu; Yasuta, Masato; Harada, Yoshimi; Morikawa, Aya; Watanabe, Hidetaka; Kurokawa, Masato

    2017-06-01

    In situ splitting of rib bone graft was conducted in 22 patients for the repair of orbital fracture with no other complicating fractures. A bone graft was harvested from the sixth or seventh rib in the right side. The repair of the orbital floor and medial wall was successful in all the cases. Ten patients had bone grafting to the orbital floor, eight had it done onto medial wall, and 4 onto both floor and wall after reduction. The mean length of in situ rib bone graft was 40.9 mm (range, 20-70 mm), the mean width of these was 14.9 mm (range, 8-20 mm). The bone grafting was done by one leaf for 15 cases and two leafs for 7 cases in size of defects. The technique of in situ splitting of a rib bone graft for the repair of the orbital floor and medial wall is a simple and safe procedure, easily taking out the in situ splitting of a rib, and less pain in donor site. It has proved to be an optimal choice in craniofacial reconstruction, especially the defects of orbital floor and medial wall.

  5. A RETROSPECTIVE ANALYSIS OF ARTHROSCOPIC ACL RECONSTRUCTION WITH HAMSTRING TENDON GRAFT

    Directory of Open Access Journals (Sweden)

    Ashish R. Agarwal

    2017-08-01

    Full Text Available BACKGROUND ACL reconstruction is one of the commonest knee surgeries done. Young adults are the commonest patients; thus, this injury has a large impact on socioeconomic status of the family. The aim of the study is to study the outcome of arthroscopic ACL reconstruction with hamstring tendon graft. MATERIALS AND METHODS 50 patients following up in the OPD who had undergone ACL reconstruction with hamstring tendon graft are evaluated. Patients who had other lesions, such meniscal injuries or collateral injuries were discarded. These patients were evaluated by using Tegner and Lysholm score of 6 months, 12 months and 24 months. Settings- It is a retrospective analysis of the data collected from the patients who were opiated at Nair Hospital. RESULTS 90% of patients in the study were males. Mean age of the study population is 30.7 years. All the patients in the study had instability as a symptom, while 80% of them also had pain. Six months after surgery, according to Tegner and Lysholm score, 52% patients had good outcome, while 48% had fair outcome. At 2 years, 98% of study population had excellent outcome. CONCLUSION Arthroscopic ACL reconstruction with hamstring graft is an effective way of treating ACL tear.

  6. Potential advantages of treatment of transplanted saphenous vein aorto-coronary artery bypass grafts with beta irradiation to prevent graft occlusion.

    Science.gov (United States)

    Smith, R G

    1997-01-01

    Intimal proliferation or Neointimal hyperplasia (NIH) is a vascular lesion that often arises in arteries after balloon angioplasty or other vessel wall injuries. FIH is a vascular lesion that develops in autologous saphenous vein grafts (SVG) after transplantation into the aorto-coronary circulation or the peripheral vascular circulation. FIH shares elements of smooth muscle migration, proliferation and fibrous tissue deposition in common with nibrointimal proliferation (NIH). Either NIH of a coronary artery or FIH of a SVG obstruct the vascular lumen and result in myocardial dysfunction. Local radiotherapy has been used for several decades to reduce the post-operative recurrence of the fibrovascular proliferations of pterygia and keloids. Similarly, in animal and human experiments, endovascular radiotherapy has been shown to reduce arterial smooth muscle proliferation. Consideration of the similarities of vascular smooth muscle cell proliferation in NIH and FIH leads one to suggest that endovascular beta irradiation can reduce FIH as well as it reduces NIH. The goal of such treatment is to achieve a clinically significant decrease in the morbidity and mortality resulting from SVG occlusions. The potential for large reduction of the consequences of SVG occlusion, the very large number of patients at risk, and the simplicity of the proposed intervention encourages prompt scientific evaluation of this technique.

  7. Tibial tunnel and pretibial cysts following ACL graft reconstruction: MR imaging diagnosis

    Energy Technology Data Exchange (ETDEWEB)

    Ghazikhanian, Varand [Brigham and Women' s Hospital, Musculoskeletal Imaging and Intervention, Department of Radiology, Boston, MA (United States); Beltran, Javier [Maimonides Medical Center, Brooklyn, NY (United States); Nikac, Violeta [Maimonides Medical Center, Department of Radiology, Brooklyn, NY (United States); Bencardino, Jenny T. [NYU Hospital for Joint Diseases, New York, NY (United States); Feldman, Marina

    2012-11-15

    Tunnel cyst formation is a rare complication after anterior cruciate ligament reconstruction, usually occurring 1-5 years post-operatively, which may occasionally be symptomatic. There are multiple proposed theories regarding the etiology of tunnel cysts. Theories include necrosis, foreign-body reaction, lack of complete graft osteo-integration, and intravasation of articular fluid. It is important to know if the tunnel cysts are communicating or not communicating with the joint, as surgical management may be different. Imaging characteristics on magnetic resonance images (MRI) include tibial tunnel widening, multilocular or unilocular cyst formation in the graft or tibial tunnel, with possible extension into the pretibial space, intercondylar notch, and/or popliteal fossa. The MR imaging differential diagnosis of tibial tunnel cysts includes infection, foreign-body granuloma, or tibial screw extrusion. Importantly, to the best of our knowledge, graft failure or instability has not been reported in association with tibial tunnel cysts. (orig.)

  8. Simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft.

    Science.gov (United States)

    Shin, Sang-Jin; Campbell, Sean; Scott, Jonathan; McGarry, Michelle H; Lee, Thay Q

    2014-09-01

    The purpose of this study was to introduce a novel surgical technique for simultaneous anatomic reconstruction of the acromioclavicular and coracoclavicular ligaments using a single tendon graft and to compare its biomechanical characteristics to those of a coracoid cerclage reconstruction of the coracoclavicular ligaments. Six matched pairs of human acromioclavicular joints with an average age of 54.8 ± 7.8 years were used. One shoulder from each pair received the single tendon acromioclavicular-coracoclavicular reconstruction; the contralateral shoulder received the coracoid cerclage reconstruction. Bovine extensor tendon was used for both techniques. The single tendon acromioclavicular-coracoclavicular reconstruction technique provided anatomic restoration of the two coracoclavicular ligaments and the superior and inferior acromioclavicular ligaments simultaneously using one coracoid hole, one acromion hole, and two clavicular holes with interference screws. Anterior-posterior and superior-inferior translations were quantified for all specimens before and after reconstruction, followed by load to failure testing. Following coracoid cerclage reconstruction, total anterior-posterior translation was significantly greater than intact (10.0 ± 5.7 mm; p = 0.008). Following single tendon acromioclavicular-coracoclavicular reconstruction, there was no significant difference in anterior-posterior translation compared to intact (-1.6 ± 2.2 mm; n.s.). The coracoid cerclage technique demonstrated significantly greater anterior-posterior translation than the single tendon acromioclavicular-coracoclavicular technique (p = 0.007). Both techniques restored superior-inferior translation to the intact condition (n.s.). Ultimate load, deformation at ultimate load, and energy absorbed at ultimate load were significantly greater after acromioclavicular-coracoclavicular reconstruction than after coracoid cerclage reconstruction (p

  9. Anatomical reconstruction of the fourth brachymetatarsia with one-stage iliac bone and cartilage cap grafting.

    Science.gov (United States)

    Woo, Sang Hyun; Bang, Chi Young; Ahn, Hee-Chan; Kim, Sung-Jung; Choi, Jun-Young

    2017-05-01

    We present a one-stage procedure for lengthening the fourth brachymetatarsia with autogenous iliac bone and cartilage cap grafting for the anatomical reconstruction of the metatarsophalangeal (MTP) joint METHODS: During the last 8 years, 56 feet in 41 patients with congenital brachymetatarsia of the fourth toe were corrected with a one-stage operation to reposition the articular cartilage cap to the distal part of interpositional iliac bone graft at the metatarsal epiphysis. The length of the harvested iliac bone graft was 22.9 mm on average. The mean fixation period was 58.5 days, and the mean gain in length and percentage increase was 20.9 mm and 39%, respectively. MRI showed a stable MTP joint over viable cartilage cap in 83.3% of the cases. Mean postoperative American Orthopedic Foot and Ankle Society lesser MTP-interphalangeal score was 82.0. Neither neurovascular impairment nor recurrence of brachymetatarsia occurred in the mean follow-up period of 43.6 months. All patients were satisfied with the postoperative cosmetic results. Thirteen patients (23.2%) complained of limited active dorsiflexion of the fourth toe, and extensor adhesion was released by extensor tenolysis in only one patient. In a single case of nonunion at the bone graft site, additional surgery was not necessary. Anatomical reconstruction of the fourth brachymetatarsia with one-stage interpositional iliac bone and cartilage cap grafting resulted in excellent cosmetic results and a physiologic MTP joint, providing the benefits of one-stage lengthening with a low complication rate. Therapeutic, IV. Copyright © 2017 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  10. Clinical observation on the reconstruction of large areas lower eyelid defect with Medpor spacer graft

    Directory of Open Access Journals (Sweden)

    Hai-Yan Li

    2014-08-01

    Full Text Available AIM: To observe the effects of porous polyethylene(Medporas a spacer graft in the reconstruction of large areas eyelid defect after the operation of malignant tumors of lower eyelids.METHODS: Nineteen cases(19 eyesof malignant tumors of lower eyelid underwent the eyelid reconstruction were selected. Medpor lower eyelid inserts implantation were used to replace tarsal joint sliding conjunctival flap and pedicle flap, and repaired full-thickness lower eyelid defects then underwent eyelid reconstruction. RESULTS: Appearance of eyelids and functional improvements were satisfactory with no stimulation on the eyeball and no effect on the visual function. Implants is with no absorption, shift, exclusion or infection and no tumor recurrence in all cases during the follow up for 6-36mo.CONCLUSION: Medpor lower eyelid inserts implantation can instead tarsal plate for the reconstruction of medium to large areas lower eyelid defect, which is easy performing with rare complications. It is an ideal alternatives of tarsal plate.

  11. Partial lesions of the intratemporal segment of the facial nerve: graft versus partial reconstruction.

    Science.gov (United States)

    Bento, Ricardo F; Salomone, Raquel; Brito, Rubens; Tsuji, Robinson K; Hausen, Mariana

    2008-09-01

    In cases of partial lesions of the intratemporal segment of the facial nerve, should the surgeon perform an intraoperative partial reconstruction, or partially remove the injured segment and place a graft? We present results from partial lesion reconstruction on the intratemporal segment of the facial nerve. A retrospective study on 42 patients who presented partial lesions on the intratemporal segment of the facial nerve was performed between 1988 and 2005. The patients were divided into 3 groups based on the procedure used: interposition of the partial graft on the injured area of the nerve (group 1; 12 patients); keeping the preserved part and performing tubulization (group 2; 8 patients); and dividing the parts of the injured nerve (proximal and distal) and placing a total graft of the sural nerve (group 3; 22 patients). Fracture of the temporal bone was the most frequent cause of the lesion in all groups, followed by iatrogenic causes (p lesion of the facial nerve is still questionable. Among these 42 patients, the best results were those from the total graft of the facial nerve.

  12. Looking beyond oral mucosa: Initial results of everted saphenous vein graft urethroplasty (eSVGU) in long anterior urethral strictures.

    Science.gov (United States)

    Akhtar, Arif; Khattar, Nikhil; Goel, Hemant; Rao, Swatantra; Tanwar, Raman; Sood, Rajeev

    2017-09-01

    To prospectively evaluate the feasibility and initial results of an everted saphenous vein graft (eSVG) as a dorsolateral onlay, in patients with long anterior urethral strictures and/or chronic tobacco users. In all, 20 patients with long anterior urethral strictures (>7 cm) and/or chronic tobacco exposed oral mucosa were included in the study. The harvested SVG was hydro-distended, detubularised, and everted. Substitution urethroplasty using an eSVG was performed using a dorsolateral onlay technique. Symptoms were assessed using the International Prostate Symptom Score (IPSS) and uroflowmetry at 1, 3 and 6 months; and voiding and retrograde urethrograms, and urethroscopy were done at 3 months. Failure was defined as failure to void, need for interventions in form of direct-vision internal urethrotomy or endodilatation. Three patients were excluded because they underwent a staged urethroplasty. In all, 17 patients underwent eSVG substitution urethroplasty. The mean (SD, range) follow-up of our patients was 17.64 (5.23, 10-26) months. The mean (SD, range) length of the strictured segment was 14 (2.5, 10-18) cm and the length of the harvested SVG was 16.3 (2.7, 12-20) cm. The mean (SD) IPSS at 1, 3 and 6 months after catheter removal was 10 (2.8), 10 (3.4) and 10 (1.4) and the quality-of-life score was 1.76 (0.5), 2.05 (1.0) and 2.05 (1.0), respectively. Postoperatively, endodilatation was required in two patients. Complete failure occurred in one patient. An eSVG, as a dorsolateral onlay graft, is a promising and prudent option for long anterior urethral strictures, especially in patients with poor oral hygiene and chronic tobacco use.

  13. Nonexpansive immediate breast reconstruction using human acellular tissue matrix graft (AlloDerm).

    Science.gov (United States)

    Salzberg, C Andrew

    2006-07-01

    Immediate breast reconstruction has become a standard of care following mastectomy for cancer, largely due to improved esthetic and psychologic outcomes achieved with this technique. However, the current historical standards--transverse rectus abdominis myocutaneous flap reconstruction and expander--implant surgery-still have limitations as regards patient morbidity, short-term body-image improvements, and even cost. To address these shortcomings, we employ a novel concept of human tissue replacement to enhance breast shape and provide total coverage, enabling immediate mound reconstruction without the need for breast expansion prior to permanent implant placement. AlloDerm (human acellular tissue matrix) is a human-derived graft tissue with extensive experience in various settings of skin and soft tissue replacement surgery. This report describes the success using acellular tissue matrix to provide total coverage over the prosthesis in immediate reconstruction, with limited muscle dissection. In this population, 49 patients (76 breasts) successfully underwent the acellular tissue matrix-based immediate reconstruction, resulting in durable breast reconstruction with good symmetry. These findings may predict that acellular tissue matrix-supplemented immediate breast reconstruction will become a new technique for the immediate reconstruction of the postmastectomy breast.

  14. Split thickness skin graft for cervicovaginal reconstruction in congenital atresia of cervix.

    Science.gov (United States)

    Zhang, Xuyin; Han, Tiantian; Ding, Jingxin; Hua, Keqin

    2015-10-01

    To introduce a new technique that combines laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in patients with congenital atresia of the cervix. Video article introducing a new surgical technique. University hospital. A 16-year-old patient with congenital cervical atresia, vaginal dysgenesis, and ovarian endometrial cyst. An original technique of combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft for cervicovaginal reconstruction. A midline incision at the vaginal introitus was made, and a 9-cm canal was made between the bladder and the rectum using sharp and blunt dissection along the anatomic vaginal route, with the aid of laparoscopy to ensure correct orientation. A 14 × 12 cm split thickness skin graft was harvested from the right lateral thigh. By laparoscopy, the level of the lowest pole of the uterine cavity was exposed and the cervix was incised by shape dissection. The proximal segment of the harvested skin to the lower uterine segment was secured, and the distal segment was sutured with the upper margin of vulva vaginally. Surgical technique reports in anonymous patients are exempted from ethical approval by the Institutional Review Board. The patient gave consent to use the video in the article. The procedure was successfully completed. Since February 2013, our experiences of combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in 10 patients with congenital atresia of cervix were positive, with successful results and without complications or cervical, or vaginal stenosis. Our technique is feasible and safe for congenital atresia of cervix, with successful results and without complications or cervical or vaginal stenosis. Copyright © 2015 American Society for Reproductive Medicine. Published by Elsevier Inc. All rights reserved.

  15. Collagen-grafted porous HDPE/PEAA scaffolds for bone reconstruction.

    Science.gov (United States)

    Kim, Chang-Shik; Jung, Kyung-Hye; Kim, Hun; Kim, Chan-Bong; Kang, Inn-Kyu

    2016-01-01

    After tumor resection, bone reconstruction such as skull base reconstruction using interconnected porous structure is absolutely necessary. In this study, porous scaffolds for bone reconstruction were prepared using heat-pressing and salt-leaching methods. High-density polyethylene (HDPE) and poly(ethylene-co-acrylic acid) (PEAA) were chosen as the polymer composites for producing a porous scaffold of high mechanical strength and having high reactivity with biomaterials such as collagen, respectively. The porous structure was observed through surface images, and its intrusion volume and porosity were measured. Owing to the carboxylic acids on PEAA, collagen was successfully grafted onto the porous HDPE/PEAA scaffold, which was confirmed by FT-IR spectroscopy and electron spectroscopy for chemical analysis. Osteoblasts were cultured on the collagen-grafted porous scaffold, and their adhesion, proliferation, and differentiation were investigated. The high viability and growth of the osteoblasts suggest that the collagen-grafted porous HDPE/PEAA is a promising scaffold material for bone generation.

  16. Complications of grafts used in female pelvic floor reconstruction: Mesh erosion and extrusion

    Directory of Open Access Journals (Sweden)

    Tanya M Nazemi

    2007-01-01

    Full Text Available Introduction: Various grafts have been used in the treatment of urinary incontinence and pelvic prolapse. Autologous materials such as muscle and fascia were first utilized to provide additional anatomic support to the periurethral and pelvic tissues; however, attempts to minimize the invasiveness of the procedures have led to the use of synthetic materials. Complications such as infection and erosion or extrusion associated with these materials may be troublesome to manage. We review the literature and describe a brief overview of grafts used in pelvic floor reconstruction and focus on the management complications specifically related to synthetic materials. Materials and Methods: We performed a comprehensive review of the literature on grafts used in pelvic floor surgery using MEDLINE and resources cited in those peer-reviewed manuscripts. The results are presented. Results: Biologic materials provide adequate cure rates but have associated downfalls including potential complications from harvesting, variable tissue quality and cost. The use of synthetic materials as an alternative graft in pelvic floor repairs has become a popular option. Of all synthetic materials, the type I macroporous polypropylene meshes have demonstrated superiority in terms of efficacy and fewer complication rates due to their structure and composition. Erosion and extrusion of mesh are common and troublesome complications that may be managed conservatively with observation with or without local hormone therapy, with transvaginal debridement or with surgical exploration and total mesh excision, dependent upon the location of the mesh and the mesh type utilized. Conclusions: The ideal graft would provide structural integrity and durability with minimal adverse reaction by the host tissue. Biologic materials in general tend to have fewer associated complications, however, the risks of harvesting, variable integrity of allografts, availability and high cost has led to the

  17. Biomechanical Evaluation of Glenoid Reconstruction With an Implant-Free J-Bone Graft for Anterior Glenoid Bone Loss.

    Science.gov (United States)

    Pauzenberger, Leo; Dyrna, Felix; Obopilwe, Elifho; Heuberer, Philipp R; Arciero, Robert A; Anderl, Werner; Mazzocca, Augustus D

    2017-10-01

    The anatomic restoration of glenoid morphology with an implant-free J-shaped iliac crest bone graft offers an alternative to currently widely used glenoid reconstruction techniques. No biomechanical data on the J-bone grafting technique are currently available. To evaluate (1) glenohumeral contact patterns, (2) graft fixation under cyclic loading, and (3) the initial stabilizing effect of anatomic glenoid reconstruction with the implant-free J-bone grafting technique. Controlled laboratory study. Eight fresh-frozen cadaveric shoulders and J-shaped iliac crest bone grafts were used for this study. J-bone grafts were harvested, prepared, and implanted according to a previously described, clinically used technique. Glenohumeral contact patterns were measured using dynamic pressure-sensitive sensors under a compressive load of 440 N with the humerus in (a) 30° of abduction, (b) 30° of abduction and 60° of external rotation, (c) 60° of abduction, and (d) 60° of abduction and 60° of external rotation. Using a custom shoulder-testing system allowing positioning with 6 degrees of freedom, a compressive load of 50 N was applied, and the peak force needed to translate the humeral head 10 mm anteriorly at a rate of 2.0 mm/s was recorded. All tests were performed (1) for the intact glenoid, (2) after the creation of a 30% anterior osseous glenoid defect parallel to the longitudinal axis of the glenoid, and (3) after anatomic glenoid reconstruction with an implant-free J-bone graft. Furthermore, after glenoid reconstruction, each specimen was translated anteriorly for 5 mm at a rate of 4.0 mm/s for a total of 3000 cycles while logging graft protrusion and mediolateral bending motions. Graft micromovements were recorded using 2 high-resolution, linear differential variable reluctance transducer strain gauges placed in line with the long leg of the graft and the mediolateral direction, respectively. The creation of a 30% glenoid defect significantly decreased glenohumeral

  18. Anterior cruciate ligament reconstruction with tibial attachment preserving hamstring graft without implant on tibial side

    Directory of Open Access Journals (Sweden)

    Skand Sinha

    2018-01-01

    Full Text Available Background: Tibial attachment preserving hamstring graft could prevent potential problems of free graft in anterior cruciate ligament (ACL reconstruction such as pull out before graft-tunnel healing or rupture before ligamentization. Different implants have been reportedly used for tibial side fixation with this technique. We investigated short-term outcome of ACL reconstruction (ACLR with tibial attachment sparing hamstring graft without implant on the tibial side by outside in technique. Materials and Methods: Seventy nine consecutive cases of ACL tear having age of 25.7 ± 6.8 years were included after Institutional Board Approval. All subjects were male. The mean time interval from injury to surgery was of 7.5 ± 6.4 months. Hamstring tendons were harvested with open tendon stripper leaving the tibial insertion intact. The free ends of the tendons were whip stitched, quadrupled, and whip stitched again over the insertion site of hamstring with fiber wire (Arthrex. Single bundle ACLR was done by outside in technique and the femoral tunnel was created with cannulated reamer. The graft was pulled up to the external aperture of femoral tunnel and fixed with interference screw (Arthrex. The scoring was done by Lysholm, Tegner, and KT 1000 by independent observers. All cases were followed up for 2 years. Results: The mean length of quadrupled graft attached to tibia was 127.65 ± 7.5 mm, and the mean width was 7.52 ± 0.78 mm. The mean preoperative Lysholm score of 47.15 ± 9.6, improved to 96.8 ± 2.4 at 1 year. All cases except two returned to the previous level of activity after ACLR. There was no significant difference statistically between preinjury (5.89 ± 0.68 and postoperative (5.87 ± 0.67 Tegner score. The anterior tibial translation (ATT (KT 1000 improved from 11.44 ± 1.93 mm to 3.59 ± 0.89 mm. The ATT of operated knee returned to nearly the similar value as of the opposite knee (3.47 ± 1.16 mm. The Pivot shift test was negative in

  19. Reconstruction of large upper eyelid defects with a free tarsal plate graft and a myocutaneous pedicle flap plus a free skin graft

    DEFF Research Database (Denmark)

    Toft, Peter B

    2016-01-01

    skin graft. RESULTS: All patients healed without necrosis, did not suffer from lagophthalmos, achieved reasonable cosmesis, and did not need lubricants. In one patient, a contact lens was necessary for three weeks because of corneal erosion. One patient still needs a contact lens 3 months after...... excision to avoid eye discomfort. CONCLUSION: Large upper eyelid defects can be reconstructed with a free tarsal plate graft and a laterally based myocutaneous pedicle flap in combination with a free skin graft. Two-step procedures can probably be avoided in most cases....

  20. Distally based sural neuro-fasciocutaneous perforator flap for foot and ankle reconstruction: Surgical modifications for flap pedicle and donor site closure without skin graft.

    Science.gov (United States)

    Chi, Zhenglin; Chen, Yiheng; Chu, Tinggang; Gao, Weiyang; Li, Zhijie; Yan, Hede; Song, Yonghuan

    2018-02-01

    The conventional procedure of the sural neuro-fasciocutaneous flap enables the supply of blood and venous drainage by increasing the width of the adipofascial tissue and preserving tiny venous return routes. Moreover, skin graft is a common method for donor site closure, which may lead to some complications and influence the aesthetic appearance. We report modifications for a distally based sural neuro-fasciocutaneous perforator flap and a relaying flap for donor site closure without skin graft. Twelve patients undergoing the modified flap for foot and ankle reconstruction were included in this study between 2014 and 2016. A peroneal-based perforator, a superficial vein, and the vascular axis of the sural nerve were included in the pedicle. A Z-shape skin incision was performed to explore the perforator vessels and a relaying island perforator flap was used to close the donor site. All flaps survived completely without necrosis. The area of the flaps ranged from 16 × 8 cm to 30 × 15 cm. The diameter width of the pedicle ranged from 1.0 to 2.0 cm. A relaying perforator island flap was used in 10 cases for donor site closure and no skin graft was performed. There were no serious donor site complications. All patients were satisfied with the aesthetic outcome postoperatively at the final follow-up. The distally based sural neuro-fasciocutaneous perforator flap is considered a reliable method for foot and ankle reconstruction. The modification for flap pedicle and donor site closure method without skin graft should be recommended. Copyright © 2017. Published by Elsevier Ltd.

  1. A 10-year institutional experience with open branched graft reconstruction of aortic aneurysms in connective tissue disorders versus degenerative disease.

    Science.gov (United States)

    Hicks, Caitlin W; Lue, Jennifer; Glebova, Natalia O; Ehlert, Bryan A; Black, James H

    2017-11-01

    Aortic reconstruction for complex thoracoabdominal aortic aneurysms (TAAAs) can be challenging, especially in patients with connective tissue disorders (CTDs) in whom tissue fragility is a major concern. Branched graft reconstruction is a more complex operation compared with inclusion patch repair of the aorta but is frequently necessary in patients with CTDs or other pathologies because of anatomic reasons. We describe our institutional experience with open branched graft reconstruction of aortic aneurysms and compare outcomes for patients with CTDs vs degenerative pathologies. We retrospectively analyzed all patients undergoing open aortic reconstruction using branched grafts at our institution between July 2006 and December 2015. Postoperative outcomes, including perioperative morbidity and mortality, midterm graft patency, and the development of new aneurysms, were compared for patients with CTD vs degenerative disease. During the 10-year study period, 137 patients (CTD, 29; degenerative, 108) underwent aortic repair with branched graft reconstruction. CTD patients were significantly younger (39 ± 1.9 vs 68 ± 1.0 years; P disease, coronary artery disease; P degenerative disease. Perioperative mortality (CTD: 10% [n = 3] vs degenerative: 6% [n = 6]; P = .40) and any complication (62% vs 55%; P = .47) were similar between groups. At a median follow-up time of 14.5 months (interquartile range: 6.5, 43.9 months), CTD patients were more likely to develop both new aortic (21%) and nonaortic (14%) aneurysms compared with the degenerative group (7% and 4% for aortic and nonaortic aneurysms, respectively; P = .02). Loss of branch graft patency occurred in 0 of 99 grafts (0%) in CTD patients and in 13 of 167 grafts (7.8%) in degenerative disease patients (P = .005). Loss of branch graft patency occurred most commonly in left renal artery bypass grafts (77%) and was clinically asymptomatic (creatinine: 1.77 ± 0.13 mg/dL currently vs 1.41 ± 0

  2. Reconstruction of epidermis by grafting of keratinocytes cultured on polymer support--clinical study.

    Science.gov (United States)

    Dvoránková, Barbora; Holíková, Zuzana; Vacík, Jirí; Königová, Radana; Kapounková, Zuzana; Michálek, Jirí; Prádn, Martin; Smetana, Karel

    2003-03-01

    Extensive wound coverage still represents a challenge for contemporary medicine. We demonstrate the results of a clinical trial of the grafting of cultured keratinocytes directly on a polymer cultivation support in the treatment of skin defects in seriously burned patients and in patients with trophic ulcers. Wound closure was evaluated clinically. The morphology and phenotypic pattern of the reconstructed epidermis, including the basal lamina, as well as the presence of Langerhans cells, were evaluated immunocytochemically using a panel of monoclonal antibodies. All layers of the reconstructed epidermis were normally differentiated (cytokeratin immunocytochemistry). The basal lamina contained collagen type IV and laminin. The reconstructed epidermis was extensively colonized by Langerhans cells. The results of the described technology are encouraging, especially in patients after a burn injury. The described procedure is suitable for the treatment of skin defects in clinical practice.

  3. Biomechanical Comparison of an Intramedullary and Extramedullary Free-Tissue Graft Reconstruction of the Acromioclavicular Joint Complex

    Science.gov (United States)

    Garg, Rishi; Javidan, Pooya; Lee, Thay Q.

    2013-01-01

    Background Several different surgical techniques have been described to address the coracoclavicular (CC) ligaments in acromioclavicular (AC) joint injuries. However, very few techniques focus on reconstructing the AC ligaments, despite its importance in providing stability. The purpose of our study was to compare the biomechanical properties of two free-tissue graft techniques that reconstruct both the AC and CC ligaments in cadaveric shoulders, one with an extramedullary AC reconstruction and the other with an intramedullary AC reconstruction. We hypothesized intramedullary AC reconstruction will provide greater anteroposterior translational stability and improved load to failure characteristics than an extramedullary technique. Methods Six matched cadaveric shoulders underwent translational testing at 10 N and 15 N in the anteroposterior and superoinferior directions, under AC joint compression loads of 10 N, 20 N, and 30 N. After the AC and CC ligaments were transected, one of the specimens was randomly assigned the intramedullary free-tissue graft reconstruction while its matched pair received the extramedullary graft reconstruction. Both reconstructed specimens then underwent repeat translational testing, followed by load to failure testing, via superior clavicle distraction, at a rate of 50 mm/min. Results Intramedullary reconstruction provided significantly greater translational stability in the anteroposterior direction than the extramedullary technique for four of six loading conditions (p < 0.05). There were no significant differences in translational stability in the superoinferior direction for any loading condition. The intramedullary reconstructed specimens demonstrated improved load to failure characteristics with the intramedullary reconstruction having a lower deformation at yield and a higher ultimate load than the extramedullary reconstruction (p < 0.05). Conclusions Intramedullary reconstruction of the AC joint provides greater stability in the

  4. Does the graft-tunnel friction influence knee joint kinematics and biomechanics after anterior cruciate ligament reconstruction? A finite element study.

    Science.gov (United States)

    Wan, Chao; Hao, Zhixiu

    2018-02-01

    Graft tissues within bone tunnels remain mobile for a long time after anterior cruciate ligament (ACL) reconstruction. However, whether the graft-tunnel friction affects the finite element (FE) simulation of the ACL reconstruction is still unclear. Four friction coefficients (from 0 to 0.3) were simulated in the ACL-reconstructed joint model as well as two loading levels of anterior tibial drawer. The graft-tunnel friction did not affect joint kinematics and the maximal principal strain of the graft. By contrast, both the relative graft-tunnel motion and equivalent strain for the bone tunnels were altered, which corresponded to different processes of graft-tunnel integration and bone remodeling, respectively. It implies that the graft-tunnel friction should be defined properly for studying the graft-tunnel integration or bone remodeling after ACL reconstruction using numerical simulation.

  5. Reconstruction of long digital extensor tendon by cranial tibial muscle fascia graft in a dog.

    Science.gov (United States)

    Sabiza, Soroush; Khajeh, Ahmad; Naddaf, Hadi

    2016-01-01

    Tendon rupture in dogs is generally the result of a direct trauma. This report described the use of adjacent muscle autogenic fascial graft for reconstruction of distal rupture of long digital extensor tendon in a dog. A two-year-old male mix breed dog, was presented with a non-weight bearing lameness of the right hind limb and a deep rupture of lateral side of right tarsus. History taking revealed that this rupture appeared without any apparent cause, when walking around the farm, three days before. Radiography was done and no fracture was observed. Hyperextension of right tarsal joint compared to left limb was observed. Under general anesthesia, after dissections of the ruptured area, complete rupture of long digital extensor tendon was revealed. Then, we attempted to locate the edge of the tendon, however, the tendon length was shortened approximately 1 cm. Hence, a strip of 1 cm length from fascia of cranial tibial muscle was harvested to fill the defect. The graft was sutured to the two ends of tendon using locking loop pattern. Subcutaneous layers and the skin were sutured routinely. Ehmer sling bandage was applied to prevent weight bearing on the surgical region. Re-examination and phone contact with the owner eight weeks and six months postoperatively revealed a poor lameness and excellent function of the dog, respectively. It could be concluded that the fascia of adjacent muscles can be used as an autogenic graft for reconstruction of some tendon ruptures.

  6. [Mesenteric-cava shunt's results with autologous jugular vein graft in children with pre-sinusoidal portal hypertension].

    Science.gov (United States)

    Leal, N; López Santamaría, M; Gámez, M; Murcia, J; Andolfi, G; Berrocal, T; Frauca, E; Jara, P; Tovar, J

    2002-07-01

    Presinusoidal portal hypertension (PPH) in children evaluates without functional hepatic damage, and with the time, trends to compensate through the creation of spontaneous portosystemic shunts. Nevertheless, some patients suffer episodes of gastrointestinal bleeding (GIB) that because of its frequency or severity, force to propose the change of surgical treatment. To evaluate the results of the mesocaval shunt (MCS) with autologous jugular vein in children with PPH. Among the 32 children with PPH treated in our Hospital in the last 7 years, 10 had episodes of GIB that forced to perform a surgical shunt. The types of shunt were distal splenorenal in 3 patients and mesocaval in 7. These 7 cases are the material of this study. The origin of the PPH was a cavernomatosis transformation of the portal vein in 6 cases and a congenital hepatic fibrosis in 1. Before the surgery the average number of episodes of GIB was 9 (range 2-15); all the patients needed transfusion of blood products and variceal sclerosis. In 2 cases a tamponade with the Sengtaken balloon was required and 5 patients were treated with somatostatin and propranolol. The Doppler ultrasounds revealed and intense hepatofugal collateral circulation in all the cases. The initial flow through the shunt was adequate in all the patients except one who required a percutaneous balloon dilatation. Only this patient has suffered an episode of GIB. The hyperesplenism signs disappeared or improved in all the seven cases and the collateral circulation was significantly reduced. The pressure in the splenic territory decreased around 50% in the 4 patients that was measured. There were no cases of encephalopasty and only one child with congenital hepatic fibrosis shows signs of mild hepatic disfunction. The medium follow up post-shunt is 32 months (range 8 m-6 years). The MCS prevents the GIB in the PPH not responsive to the conservative treatment; its effectiveness is related with an adequate permeability though the graft

  7. Reconstruction of partially amputated external ear with costal cartilage graft: case report.

    Science.gov (United States)

    Brunelli, A; Bottini, D J; Cervelli, V; Cervelli, G; Grimaldi, M

    2004-06-01

    Many causes are responsible for secondary anomalies of the outer ear, such as: car accidents, sport- or work-related accidents, assaults, bites from animals or humans, benign or malignant tumours, burns and the effects of surgical interventions of the ear (plastic surgery on the ear or attempts at correction of primary malformations of the ear). The anatomical complexity of the ear makes its reconstruction particularly complicated with post-operative results that are often disappointing. The Authors describe their experience in the reconstruction of a partially amputated outer ear following a dog bite. The therapeutic protocol required various surgical stages. Initially, a cutaneous expander was applied at the level of the mastoid in order to ensure a sufficient quantity of local skin. The second stage was to remove cartilage from the ribs, followed by construction of a cartilaginous model of the ear and its insertion into the subcutaneous mastoid region after removal of the cutaneous expander and any residual ear cartilage. The last stage was to separate the neo-formed outer ear from the mastoid skin with the insertion of a cartilage graft to the posterior region of the reconstructed ear. This graft was covered by the occipital fascia rotated at 180 degrees and by a skin graft removed from the pubis. The postoperative result was satisfactory with recuperation of a good aesthetic appearance of the ear. Aim of the present report is to describe the surgical technique employed in the reconstruction of secondary anomalies of the ear and to highlight errors committed during this procedure. These considerations have allowed us to stress some fundamental elements in the reconstruction of the ear. In particular, the watershed was the awareness that we had to create a cartilaginous model that respected, as far as possible, the anatomy of the outer ear with all its ridges, trenches and cavities. This as well as ensuring a sufficient quantity of local skin in order to cover

  8. Reconstruction of internal nasal valve, septum, dorsum, and anterior structures of the nose in a single procedure with a molded bone graft: the sail graft.

    Science.gov (United States)

    Guneren, Ethem; Ciftci, Mehmet; Karaaltin, Mehmet Veli; Yildiz, Kemalettin

    2012-05-01

    Excessive surgical removal or traumatic loss of the tissues supporting the nasal roof can result in the "saddle nose" deformity. It involves both cartilage and bone deficiencies. Two main resources are used to reconstruct this difficult deformity: autogenous bone and cartilage grafts and alloplastic materials. This study presents the reconstruction of the dorsum, septum, internal nasal valve, and anterior structures and the tip of the nose using a block of molded autogenous bone graft. We called it the "sail graft," because it looks like a sail from a lateral view. The mast of the sail is oriented in a superior-to-inferior direction, beginning in the frontonasal region to the tip of the nose to form a straight, well-rounded dorsum. The longest postoperative follow-up of 13 cases is now 10 years; the median follow-up is 2 years. The results have been satisfactory.

  9. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Science.gov (United States)

    Liu, Jingbo; Wang, Jun; Luo, Fen; Wang, Zhiming; Wang, Yin

    2013-01-01

    Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG) and the vagal resection group (VG). The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis). Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  10. Reconstruction of the abdominal vagus nerve using sural nerve grafts in canine models.

    Directory of Open Access Journals (Sweden)

    Jingbo Liu

    Full Text Available BACKGROUND: Recently, vagus nerve preservation or reconstruction of vagus has received increasing attention. The present study aimed to investigate the feasibility of reconstructing the severed vagal trunk using an autologous sural nerve graft. METHODS: Ten adult Beagle dogs were randomly assigned to two groups of five, the nerve grafting group (TG and the vagal resection group (VG. The gastric secretion and emptying functions in both groups were assessed using Hollander insulin and acetaminophen tests before surgery and three months after surgery. All dogs underwent laparotomy under general anesthesia. In TG group, latency and conduction velocity of the action potential in a vagal trunk were measured, and then nerves of 4 cm long were cut from the abdominal anterior and posterior vagal trunks. Two segments of autologous sural nerve were collected for performing end-to-end anastomoses with the cut ends of vagal trunk (8-0 nylon suture, 3 sutures for each anastomosis. Dogs in VG group only underwent partial resections of the anterior and posterior vagal trunks. Laparotomy was performed in dogs of TG group, and latency and conduction velocity of the action potential in their vagal trunks were measured. The grafted nerve segment was removed, and stained with anti-neurofilament protein and toluidine blue. RESULTS: Latency of the action potential in the vagal trunk was longer after surgery than before surgery in TG group, while the conduction velocity was lower after surgery. The gastric secretion and emptying functions were weaker after surgery in dogs of both groups, but in TG group they were significantly better than in VG group. Anti-neurofilament protein staining and toluidine blue staining showed there were nerve fibers crossing the anastomosis of the vagus and sural nerves in dogs of TG group. CONCLUSION: Reconstruction of the vagus nerve using the sural nerve is technically feasible.

  11. Adult-Brain-Derived Neural Stem Cells Grafting into a Vein Bridge Increases Postlesional Recovery and Regeneration in a Peripheral Nerve of Adult Pig

    Directory of Open Access Journals (Sweden)

    Olivier Liard

    2012-01-01

    Full Text Available We attempted transplantation of adult neural stem cells (ANSCs inside an autologous venous graft following surgical transsection of nervis cruralis with 30 mm long gap in adult pig. The transplanted cell suspension was a primary culture of neurospheres from adult pig subventricular zone (SVZ which had been labeled in vitro with BrdU or lentivirally transferred fluorescent protein. Lesion-induced loss of leg extension on the thigh became definitive in controls but was reversed by 45–90 days after neurosphere-filled vein grafting. Electromyography showed stimulodetection recovery in neurosphere-transplanted pigs but not in controls. Postmortem immunohistochemistry revealed neurosphere-derived cells that survived inside the venous graft from 10 to 240 post-lesion days and all displayed a neuronal phenotype. Newly formed neurons were distributed inside the venous graft along the severed nerve longitudinal axis. Moreover, ANSC transplantation increased CNPase expression, indicating activation of intrinsic Schwann cells. Thus ANSC transplantation inside an autologous venous graft provides an efficient repair strategy.

  12. Immediate reconstruction with autologous fat grafting: influence in breast cancerregional recurrence.

    Science.gov (United States)

    Stumpf, Camile Cesa; Biazus, Jorge Villanova; Zucatto, Fernando Schuh Ângela Erguy; Cericatto, Rodrigo; Cavalheiro, José Antônio Crespo; Damin, Andrea Pires Souto; Melo, Márcia Portela

    2017-01-01

    to evaluate local and systemic recurrence of breast cancer in patients submitted to autologous fat grafting in the immediate reconstruction after conservative surgery for breast cancer. this is a historical cohort study comparing 167 patients submitted to conservative surgery without reconstruction (conservative surgery group) with 27 patients submitted to conservative treatment with immediate graft reconstruction, following the Coleman's technique (lipofilling group). All patients had invasive carcinoma and were operated by a single surgeon from 2004 to 2011. The postoperative follow-up time was 36 months. the overall incidence of local recurrence was 2.4%. No patient in the lipofilling group had local recurrence during the study period. For systemic recurrence, the rates obtained were 3.7% (one patient) for the fat grafting group and 1.8% (three patients) for the conservative surgery group without reconstruction. there was no significant difference for local or systemic recurrence in the groups studied. Immediate autologous fat grafting appears to be a safe procedure. avaliar recorrência local e sistêmica do câncer de mama em pacientes submetidas ao enxerto autólogo de gordura na reconstrução imediata após cirurgia conservadora para o câncer de mama. estudo de coorte histórica em que foram comparadas 167 pacientes submetidas à cirurgia conservadora sem reconstrução com 27 pacientes submetidas ao tratamento conservador com reconstrução imediata do enxerto, seguindo técnica de Coleman. Todas as pacientes eram portadoras de carcinoma invasor e foram operadas por um único cirurgião, no período de 2004 a 2011. O tempo de acompanhamento pós-operatório foi 36 meses. a incidência global de recidiva local foi 2,4%. Nenhuma paciente do grupo de lipoenxertia apresentou recorrência local durante o período do estudo. Para recorrência sistêmica, as taxas obtidas foram de 3,7% (uma paciente) para o grupo lipoenxertia e 1,8% (três pacientes) para grupo

  13. Grafting

    Energy Technology Data Exchange (ETDEWEB)

    Garnett, J L [New South Wales Univ., Kensington (Australia). School of Chemistry

    1979-01-01

    The unique value of ionizing radiation for the initiation of grafting to backbone polymers is discussed. The principles of the technique are briefly reviewed. The conditions under which free radicals and ions participate in these reactions are examined. Examples of representative grafting processes are considered to illustrate where the technique can be of potential commercial value to a wide range of industries. The general principles of these grafting reactions are shown to be applicable to radiation induced rapid cure technology such as is provided by electron beam processing facilities. Grafting reactions initiated by UV are also treated and shown to be of importance because of the many similarities in properties of the ionizing radiation and UV systems, also the rapid industrial exploitation of EB and sensitized UV processing technology. Possible future trends in radiation grafting are outlined.

  14. Five-Strand versus Four-Strand Hamstring Tendon Graft Technique for Anterior Cruciate Ligament Reconstruction: A Biomechanical Comparison.

    Science.gov (United States)

    Vaillant, Eric R; Parks, Brent G; Camire, Lyn M; Hinton, Richard Y

    2017-11-01

    The aim of this article is to compare diameter and stiffness, displacement, and strain in a five-strand versus four-strand hamstring graft for anterior cruciate ligament reconstruction. Eight matched pairs of lower extremities underwent four-strand or five-strand hamstring graft reconstruction. Diameter was significantly higher in the five-strand versus the four-strand construct ( p  = 0.002). No significant difference was found between the groups in construct displacement or stiffness. Significantly higher strain was observed in the inner limb versus the outer limb in the four-strand construct ( p  = 0.001) and in the inner limb versus the fifth limb in the 5-strand construct ( p  = 0.004). A fifth limb added to a four-strand hamstring graft significantly increased graft diameter but did not significantly change stiffness or displacement, suggesting that attachment of additional graft material via suture did not provide for full incorporation of the added limb into the graft at time zero. The inner limb in both constructs absorbed significantly greater load than did other limbs. The use of suture to attach additional material to a four-strand hamstring graft may not contribute to improved biomechanical qualities of the graft at time zero. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  15. Vascularized fibula grafts for reconstruction of bone defects after resection of bone sarcomas

    DEFF Research Database (Denmark)

    Petersen, Michael Mørk; Hovgaard, Dorrit; Elberg, Jens Jørgen

    2010-01-01

    We evaluated the results of limb-sparing surgery and reconstruction of bone defects with vascularized fibula grafts in 8 consecutive patients (mean age at operation 13.6 years (range 4.1-24.2 years), female/male = 6/2) with bone sarcomas (BS) (osteosarcoma/Ewing's sarcoma/chondrosarcoma= 4....../3/1) operated on form 2000 to 2006. The bone defects reconstructed were proximal femoral diaphysis and epiphysis (n = 2), humeral diaphysis (n = 2), humeral proximal diaphysis and epiphysis (n = 1), femoral diaphysis (n = 1), ulnar diaphysis (n = 1), and tibial diaphysis (n = 1). One patient with Ewing......'s sarcoma had an early hip disarticulation, developed multiple metastases, and died 9 months after the operation. The remaining patients (n = 7) are all alive 50 months (range 26-75 months) after surgery. During the follow-up the following major complications were seen: 1-2 fractures (n = 4), pseudarthrosis...

  16. Cryopreserved Human Allografts for the Reconstruction of Aortic and Peripheral Prosthetic Graft Infection.

    Science.gov (United States)

    Bossi, Matteo; Tozzi, Matteo; Franchin, Marco; Ferraro, Stefania; Rivolta, Nicola; Ferrario, Massimo; Guttadauro, Chiara; Castelli, Patrizio; Piffaretti, Gabriele

    2017-12-25

    Background : This study aimed to present cases with cryopreserved human allografts (CHAs) for vascular reconstruction in both aortic and peripheral infected prosthetic grafts. Materials and Methods : This is a single center, observational descriptive study with retrospective analysis. In all cases, the infected prosthetic graft material was completely removed. At discharge, patients were administered anticoagulants. Follow-up examinations included clinical visits, echo-color-Doppler ultrasounds, or computed tomography angiography within 30 days and at 3, 6, and 12 months after the treatment, and then twice per year. Results : We treated 21 patients (90% men, n=19) with the mean age of 71±12 years and mean interval between the initial operation and replacement with CHA of 30 months [range, 1-216; interquartile range (IQR), 2-36]. In-hospital mortality was 14% (n=3); no CHA-related complication led to death. Limb salvage was 100%. No patient was lost at the median follow-up of 14 months (range, 2-61; IQR, 6-39). No rupture, aneurysmal degeneration, or re-infection occurred. Estimated freedom from CHA-related adverse events (95% confidence interval, 43-63) was 95% at 3 years. Conclusion : In our experience, CHAs are a viable option for prosthetic graft infections and provide satisfactory clinical results and favorable stability because of a very low rate of CHA-related adverse events during follow-up.

  17. [Bone graft reconstruction for posterior mandibular segment using the formwork technique].

    Science.gov (United States)

    Pascual, D; Roig, R; Chossegros, C

    2014-04-01

    Pre-implant bone graft in posterior mandibular segments is difficult because of masticatory and lingual mechanical constraints, because of the limited bone vascularization, and because of the difficulty to cover it with the mucosa. The formwork technique is especially well adapted to this topography. The recipient site is abraded with a drill. Grooves are created to receive and stabilize the grafts. The bone grafts were harvested from the ramus. The thinned cortices are assembled in a formwork and synthesized by mini-plates. The gaps are filled by bone powder collected during bone harvesting. The bone volume reconstructed with the formwork technique allows anchoring implants more than 8mm long. The proximity of the inferior alveolar nerve does not contra indicate this technique. The formwork size and its positioning on the alveolar crest can be adapted to prosthetic requirements by using osteosynthesis plates. The lateral implant walls are supported by the formwork cortices; the implant apex is anchored on the native alveolar crest. The primary stability of implants is high, and the torque is important. The ramus harvesting decreases operative risks. Copyright © 2014 Elsevier Masson SAS. All rights reserved.

  18. [Reconstruction of ankle and foot with combination of free perforator flaps and skin graft].

    Science.gov (United States)

    Yin, Lu; Gong, Ketong; Yin, Zhonggang; Zhang, Bo; Xu, Jianhua

    2017-03-01

    To evaluate the clinical outcomes of free perforator flaps combined with skin graft for reconstruction of ankle and foot soft tissue defects. Between June 2014 and October 2015, 20 cases of ankle and foot soft tissue defects were treated. There were 16 males and 4 females, aged from 19 to 61 years (mean, 43.3 years). Injury was caused by traffic accident in 7 cases, by crashing in 9 cases, and machine twist in 4 cases. The locations were the ankle in 6 cases, the heel in 3 cases, the dorsum pedis in 4 cases, and the plantar forefoot in 7 cases of avulsion injury after toes amputation. The size of wound ranged from 15 cm×10 cm to 27 cm×18 cm. The time from injury to treatment was from 11 to 52 days (mean, 27 days). The anterolateral thigh perforator flap was used in 11 cases, thoracodorsal antery perforator flap in 3 cases, medial sural artery perforator flap in 4 cases, deep inferior epigastric perforator flap in 1 case, and anteromedial thigh perforator flap in 1 case, including 5 chimeric perforator flaps, 5 polyfoliate perforator flaps, 3 flow-through perforator flaps, and 3 conjoined perforator flaps. The size of the perforator flap ranged from 10.0 cm×6.5 cm to 36.0 cm×8.0 cm, the size of skin graft from 5 cm×3 cm to 18 cm×12 cm. Venous crisis occurred in 2 flaps which survived after symptomatic treatment; 18 flaps survived successfully and skin grafting healed well. The follow-up time ranged 4-18 months (mean, 8.3 months). The flaps had good appearance, texture and color, without infection. The patients could walk normally and do daily activities. Only linear scars were observed at the donor sites. Free perforator flap can be used to reconstruct defects in the ankle and foot, especially in the weight-bearing area of the plantar forefoot. A combination of free perforator flap and skin graft is ideal in reconstruction of great soft tissue defects in the ankle and foot.

  19. Autologous Cricoid Cartilage as a Graft for Airway Reconstruction in an Emergent Technique - A Case Report

    Directory of Open Access Journals (Sweden)

    Farzad Izadi

    2016-03-01

    Full Text Available Introduction: Laryngotracheal stenosis can be caused after traumatic injuries to the neck from the subglottic larynx to the trachea. Patients with laryngotracheal stenosis often need a tracheotomy and occasionally may become tracheotomy dependent. Different procedures have been described for the management of these lesions. Management options include techniques of endoscopic dilation, laser resection, laryngo-fissure, and an innovative array of plastic reconstructions with or without the use of stents.   Case Report:This paper presents airway reconstruction in a young patient with severe subglottic stenosis due to a blunt trauma to the neck, who was treated using particles of an autologous fractured cricoid cartilage as the source for airway augmentation. An incision was made in the anterior midline of the cricoid lamina and deepened through the scar tissue to the posterior cricoid lamina. Then two lateral incisions (right & left were made in the cricoid lamina and fractured cartilage particles and the scar tissue were removed via these two lateral incisions. The mucosal lining at the right and left of the midline incision, after debulking, were sutured to a lateral position. Thereafter three cartilage particles were used to reconstruct the anterior cricoid lamina and augment the lumen.   Conclusion:  It is worth to mention that an autologus cartilage graft can be used for certain cases with traumatic airway stenosis. Further follow up and more patients are needed to approve this method of reconstructive surgery in emergent situations.

  20. RECONSTRUCTION OF ATROPHIC MAXILLA BY ANTERIOR ILIAC CREST BONE GRAFTING VIA NEUROAXIAL BLOCKADE TECHNIQUE: A CASE REPORT

    Directory of Open Access Journals (Sweden)

    Erol CANSIZ

    2017-01-01

    Full Text Available Anterior iliac crest bone grafting is a well-established modality in the treatment of alveolar bone deficiencies. However, this procedure may also have considerable postoperative morbidity which is mostly related to general anesthesia. Postoperative pain-related complications can be managed by neuroaxial blockade techniques which provide adequate surgical analgesia and reduce postoperative pain. This clinical report describes the reconstruction of a severely atrophic maxilla with anterior iliac crest bone grafting using combined spinal epidural anesthesia. Neuroaxial blockade techniques may be a useful alternative to eliminate general anesthesia related challenges of anterior iliac crest bone grafting procedures.

  1. Graft Utilization in the Bridging Reconstruction of Irreparable Rotator Cuff Tears: A Systematic Review.

    Science.gov (United States)

    Lewington, Matthew R; Ferguson, Devin P; Smith, T Duncan; Burks, Robert; Coady, Catherine; Wong, Ivan Ho-Bun

    2017-11-01

    Rotator cuff tears are one of the most common conditions affecting the shoulder. Because of the difficulty in managing massive rotator cuff tears and the inability of standard techniques to prevent arthropathy, surgeons have developed several novel techniques to improve outcomes and ideally alter the natural history. To systematically review the existing literature and analyze reported outcomes to evaluate the effectiveness of using a bridging graft reconstruction technique to treat large to massive irreparable rotator cuff tears. Systematic review. A systematic search of PubMed, EMBASE, CINAHL, and CENTRAL was employed with the key terms "tear," "allograft," and "rotator cuff." Eligibility was determined by a 3-phase screening process according to the outlined inclusion/exclusion criteria. Data in relation to the primary and secondary outcomes were summarized. The results were synthesized according to the origin of the graft and the level of evidence. Fifteen studies in total were included in this review: 2 comparative studies and 13 observational case series. Both the biceps tendon and the fascia lata autograft groups had significantly superior structural integrity rates on magnetic resonance imaging at 12-month minimum follow-up when compared with their partial primary repair counterparts (58% vs 26%, P = .036; 79% vs 58%, P rotator cuff tears demonstrated high structural healing rates (74%-90%, 73%-100%, and 60%-90%, respectively). Additionally, both comparative studies and case series demonstrated a general improvement of patients' functional outcome scores. Using a graft for an anatomic bridging rotator cuff repair results in improved function on objective testing and may be functionally better than nonanatomic or partial repair of large to massive rotator cuff tears. Allograft or xenograft techniques appear to be favorable options, given demonstrated functional improvement, imaging-supported graft survival, and lack of harvest complication risk. More high

  2. Hamstrings tendon graft preparation for anterior cruciate ligament reconstruction using the WhipKnotTM soft tissue cinch technique.

    Directory of Open Access Journals (Sweden)

    Amin Masoumiganjgah

    2012-04-01

    Full Text Available BackgroundAppropriate graft tension and secure graft incorporation inbone tunnels are essential for successful anterior cruciateligament (ACL reconstruction using hamstrings tendonautografts. The WhipKnot™ soft tissue cinch, introduced bySmith and Nephew in 2004, is an alternative option to thecommonly used whipstitch technique during preparation ofthe hamstring autograft in ACL reconstruction.AimsTo investigate the effectiveness of the WhipKnot™ softtissue cinch and technique during the preparation of thetendon graft for ACL reconstruction.MethodA total of 33 ACL reconstruction operations performedbetween February 2011 and December 2011 were includedin this study. These were performed by a single seniorsurgeon who used the Whipknot™ technique for thepreparation of each graft. Four were used for eachoperation; two for each end of the harvested hamstringstendons, including semitendinosus and gracilis tendonsrespectively.ResultsIn total, 132 WhipKnots were used during the kneeoperations. Use of the WhipKnot™ technique resulted insuccessful graft preparations, tensioning and effective graftplacement in the tibial and femoral tunnels in almost allinstances. Only one case of WhipKnot™ failure (slippagewas recorded.ConclusionThese results indicate that the Whipknot™ technique is asafe, reliable and practical option for the preparation of thehamstrings autografts.

  3. Procedural and clinical outcomes after use of the glycoprotein IIb/IIIa inhibitor abciximab for saphenous vein graft interventions

    Energy Technology Data Exchange (ETDEWEB)

    Harskamp, Ralf E., E-mail: r.e.harskamp@gmail.com [Academic Medical Center–University of Amsterdam, Amsterdam (Netherlands); VU University Medical Center, Amsterdam (Netherlands); Duke Clinical Research Institute, Durham, NC (United States); Hoedemaker, Niels [Academic Medical Center–University of Amsterdam, Amsterdam (Netherlands); Newby, L. Kristin [Duke Clinical Research Institute, Durham, NC (United States); Woudstra, Pier; Grundeken, Maik J.; Beijk, Marcel A.; Piek, Jan J.; Tijssen, Jan G. [Academic Medical Center–University of Amsterdam, Amsterdam (Netherlands); Mehta, Rajendra H. [Duke Clinical Research Institute, Durham, NC (United States); Winter, Robbert J. de [Academic Medical Center–University of Amsterdam, Amsterdam (Netherlands)

    2016-01-15

    Background: Percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) poses a high-risk for distal coronary thromboembolic events. Glycoprotein IIb/IIIa inhibitors are frequently used in hope of reducing the impact of this, although the safety and efficacy of these drugs to improve outcomes in this setting are understudied. Methods: Patients were included if they had prior coronary artery bypass surgery and subsequently underwent PCI of ≥ 1 SVG graft at a Dutch academic center between 1997 and 2008. These patients were matched 1:1 based on peri-procedural use of abciximab using a propensity-score matching algorithm based on 17 variables. Conditional logistic regression and Cox regression stratified on matched pairs were performed to evaluate the association between abciximab use and MACCE (the composite measure of mortality, myocardial infarction, stroke and repeat revascularization) at 30 days and up to 1 year. Results: The composite of 30-day MACCE occurred in 18 patients (15.3%) in the abciximab group and 16 patients (13.6%) in the propensity matched control group (OR: 1.13, 95% CI: 0.57–2.21, p = 0.73). At 1-year follow-up, MACCE rates were also similar (32.5% vs. 33.9%, HR: 0.97, 95% CI: 0.59–1.59). Major bleeding (BARC types 3a–c) was higher in the abciximab group (11.9% vs. 4.2%, OR: 2.80, 95% CI: 1.01–7.77). Ischemic outcomes did not differ among patients with acute coronary syndromes. Conclusion: The use of intravenous abciximab was not associated with improved clinical outcomes up to 1-year among patients undergoing SVG PCI, but was related to more bleeding. - Highlights: • PCI of SVG poses a high-risk for distal coronary thromboembolic events. • Glycoprotein IIb/IIIa inhibitors are frequently used in an attempt to reduce this risk. • We evaluated the safety and efficacy of abciximab (a glycoprotein IIb/IIIa inhibitor) using a propensity-score matched analysis of 236 patients at a large academic medical center. • Thirty

  4. Effect of ticlopidine on the long-term patency of saphenous-vein bypass grafts in the legs. Etude de la Ticlopidine après Pontage Fémoro-Poplité and the Association Universitaire de Recherche en Chirurgie.

    Science.gov (United States)

    Becquemin, J P

    1997-12-11

    Optimal therapy to prevent late occlusion of arterial bypass grafts in the legs has not been determined. We assessed the effect of ticlopidine, an inhibitor of platelet aggregation, on the long-term patency of saphenous-vein bypass grafts for the treatment of peripheral vascular disease. A total of 243 patients with femoropopliteal or femorotibial saphenous-vein bypass grafts were randomly assigned to receive either ticlopidine (250 mg twice a day) or matching placebo for two years. The primary end point was graft patency at two years, as assessed by physical examination, measurement of the ankle brachial index, and duplex ultrasonography or arteriography. The incidence of death and major ischemic events was also analyzed in the two groups. After two years, 66.4 percent of the patients were alive with a patent graft in the ticlopidine group, as compared with 51.2 percent in the placebo group (95 percent confidence interval for the difference between the two groups, 2.9 to 27.4 percent; P=0.02). The two-year cumulative patency rate was 82 percent in the ticlopidine group and 63 percent in the placebo group (P=0.002). There was no significant difference between groups in overall mortality or major ischemic events. Ticlopidine significantly improved the long-term patency of saphenous-vein bypass grafts in the legs. Since the drug was well tolerated, its use can be recommended after peripheral-vein bypass surgery.

  5. Bile duct reconstruction by a young surgeon in living donor liver transplantation using right liver graft.

    Science.gov (United States)

    Kim, Jong Man; Cho, Wontae; Kwon, Choon Hyuck David; Joh, Jae-Won; Park, Jae Berm; Ko, Justin Sangwook; Gwak, Mi Sook; Kim, Gaab Soo; Kim, Sung Joo; Lee, Suk-Koo

    2014-09-01

    Biliary strictures and bile leaks account for the majority of biliary complications after living donor liver transplantation (LDLT). The aim of this study was to examine differences in biliary complications after adult LDLTs were performed by an experienced senior surgeon and an inexperienced junior surgeon. Surgeries included bile duct reconstruction after adult LDLT using a right liver graft, and risk factors for biliary stricture were identified. We retrospectively reviewed the medical records of 136 patients who underwent LDLT in order to identify patients who developed biliary complications. The senior surgeon performed 102 surgeries and the junior surgeon performed 34 surgeries. The proportion of patients with biliary stricture was similar between the senior and the junior surgeons (27.5% vs 26.5%; P = 0.911). However, the incidence of biliary leakage was higher in patients of the junior surgeon than in those of the senior surgeon (23.5% vs 2.9%; P = 0.001). The frequency of percutaneous drainage was also higher for the junior surgeon than the senior surgeon because of the junior surgeon's high leakage rate of the drainage. When the junior surgeon performed bile duct anastomosis, biliary leakage occurred in 7 patients between the 11th and 20th cases. However, biliary leakage occurred in only 1 case thereafter. Bile duct reconstruction performed by beginner surgeons in LDLT using right lobe grafts should be cautiously monitored and observed by a senior surgeon until an inexperienced junior surgeon has performed at least 20 cases, because of the high incidence of biliary leakage related to surgeon's inexperience in bile duct reconstructions in LDLT.

  6. Anatomic single-bundle anterior cruciate ligament reconstruction improves walking economy: hamstrings tendon versus patellar tendon grafts.

    Science.gov (United States)

    Iliopoulos, Efthymios; Galanis, Nikiforos; Zafeiridis, Andreas; Iosifidis, Michael; Papadopoulos, Pericles; Potoupnis, Michael; Geladas, Nikolaos; Vrabas, Ioannis S; Kirkos, John

    2017-10-01

    Anterior cruciate ligament (ACL) injury is associated with a pathologic gait pattern and increased energy cost during locomotion. ACL reconstruction could improve the gait pattern. Hamstrings tendon (HAM) and bone-patellar tendon-bone (BPTB) grafts are usually used for reconstruction. The aim of this study was to compare the efficacy of anatomic ACL reconstruction with HAM and BPTB grafts on improving and normalizing the energy cost and physiologic reserves during flat, uphill, and downhill walking. Twenty male subjects with unilateral ACL injuries were randomly assigned to ACL reconstruction with a HAM (n = 10) or BPTB (n = 10) graft. Ten matched controls were also enrolled. All participants performed three 8-min walking tasks at 0, +10, and -10 % gradients before and 9 months after surgery. Energy cost (oxygen consumption, VO 2 ), heart rate (HR), and ventilation (VE) were measured. Lysholm/IKDC scores were recorded. Pre-operatively, VO 2 , HR, and VE were higher in the HAM and BPTB groups than in controls during walking at 0, +10, and -10 % gradients (p energy cost and nearly normalized locomotion economy and cardiorespiratory reserves during flat, uphill, and downhill walking. The improved locomotion economy is an additional benefit of anatomic ACL reconstruction, irrespective of the type of graft used, that the orthopaedic surgeons should consider. II.

  7. Evaluating different closed loop graft preparation technique for tibial suspensory fixation in ACL reconstruction using TightRope™

    Directory of Open Access Journals (Sweden)

    Takahisa Sasho

    2018-04-01

    Full Text Available In most anterior cruciate ligament (ACL reconstructions, grafts are fixed to the femoral side first followed by the tibial side. Various techniques have been reported to achieve optimal tension on the grafts, but once the grafts are fixed it is difficult to adjust graft tension further. To enable post fixation tension control we have invented a new graft configuration using an adjustable loop-device (TightRopeTM, Arthrex, FL, USA on the tibial side. In this paper, biomechanical properties of this configuration using soft tissue were examined in terms of graft diameter and various suture techniques (referred to as base suture to make a closed circle to support TightRopeTM.Two experiments were conducted under different conditions. In each experiment, cyclic load, followed by a pull-to-failure load, was applied to the grafts and elongation and failure mode were recorded. (1 To evaluate the effects of diameter, 5.0 or 6.0 mm grafts were prepared by a single locking loop stitch as the base suture (SLL5, SLL6. (2 To evaluate different base sutures, 5.0 mm tendons were used, and grafts were prepared using five kinds of base sutures (SLL, ZLL: zigzag locking loop, DZLL: double zigzag locking loop, DK: double Krackow, DK w/o TR: double Krackow without TightRopeTM. In the first experiment, tearing was observed in 2 of 6 cases in the SLL5 test group, whereas no tearing was observed with SLL6. In the second experiment, no tearing was observed with DZLL or DK. Elongation was smaller in these two groups compared to the other groups. Mechanical strength decreases with a smaller graft diameter. Biomechanical properties differed with different base sutures and, among them, the double-zigzag-suture stitch and double Krackow provided less elongation and higher ultimate load in this graft configuration.

  8. Pain following double-bundle anterior cruciate ligament reconstruction: Correlation with morphological graft findings and dynamic contrast-enhanced MRI

    International Nuclear Information System (INIS)

    Lin, Y.-C.; Mhuircheartaigh, J.N.; Cheung, Y.-C.; Juan, Y.-H.; Chiu, C.-H.; Yeh, W.-L.; Wu, J.S.

    2014-01-01

    Aim: To determine the relationship between knee pain following anterior cruciate ligament (ACL) graft placement with morphological graft findings and dynamic contrast enhancement as assessed at MRI. Material and methods: Following institutional review board approval, 37 consecutive patients with double-bundle ACL reconstruction were enrolled. Thirteen patients had pain and 24 were asymptomatic. Imaging was performed using a 1.5 T MRI machine an average of 7.6 months after surgery. Graft-related (increase signal intensity, abnormal orientation, discontinuity, cystic degeneration, anterior translation of lateral tibia, arthrofibrosis), and non-graft related causes of knee pain (meniscal tear, cartilage injury, loose bodies, and synovitis) were evaluated. During dynamic contrast enhancement analysis, peak enhancement (ePeak) was calculated by placing a region of interest at the osteoligamentous interface of each bundle. Student's t-test was used for continuous variables analysis and chi-square or Fisher's exact test was used for categorical variables analysis. Results: There was no difference between symptomatic and asymptomatic patients regarding morphological graft-related or non-graft-related causes of knee pain. For dynamic contrast enhancement analysis, symptomatic patients had significantly lower ePeak values than asymptomatic patients in the anteromedial (p = 0.008) and posterolateral (p = 0.001) bundles or when using the higher ePeak value in either bundle (p = 0.003). Conclusion: Morphological ACL graft findings as assessed at MRI could not be used to distinguish between symptomatic and asymptomatic patients. However, lower ePeak values had a significant association with knee pain. This may indicate poor neovascularization of the graft, potentially leading to graft failure. - Highlights: • Morphologic graft findings of MRI are poorly associated with knee pain. • Lower contrast enhancement values are significantly associated with knee pain

  9. Complications and Adverse Events of a Randomized Clinical Trial Comparing 3 Graft Types for ACL Reconstruction.

    Science.gov (United States)

    Mohtadi, Nicholas; Barber, Rhamona; Chan, Denise; Paolucci, Elizabeth Oddone

    2016-05-01

    Complications/adverse events of anterior cruciate ligament (ACL) surgery are underreported, despite pooled level 1 data in systematic reviews. All adverse events/complications occurring within a 2-year postoperative period after primary ACL reconstruction, as part of a large randomized clinical trial (RCT), were identified and described. Prospective, double-blind randomized clinical trial. Patients and the independent trained examiner were blinded to treatment allocation. University-based orthopedic referral practice. Three hundred thirty patients (14-50 years; 183 males) with isolated ACL deficiency were intraoperatively randomized to ACL reconstruction with 1 autograft type. Graft harvest and arthroscopic portal incisions were identical. Patients were equally distributed to patellar tendon (PT), quadruple-stranded hamstring tendon (HT), and double-bundle (DB) hamstring autograft ACL reconstruction. Adverse events/complications were patient reported, documented, and diagnoses confirmed. Two major complications occurred: pulmonary embolism and septic arthritis. Twenty-four patients (7.3%) required repeat surgery, including 25 separate operations: PT = 7 (6.4%), HT = 9 (8.2%), and DB = 8 (7.3%). Repeat surgery was performed for meniscal tears (3.6%; n = 12), intra-articular scarring (2.7%; n = 9), chondral pathology (0.6%; n = 2), and wound dehiscence (0.3%; n = 1). Other complications included wound problems, sensory nerve damage, muscle tendon injury, tibial periostitis, and suspected meniscal tears and chondral lesions. Overall, more complications occurred in the HT/DB groups (PT = 24; HT = 31; DB = 45), but more PT patients complained of moderate or severe kneeling pain (PT = 17; HT = 9; DB = 4) at 2 years. Overall, ACL reconstructive surgery is safe. Major complications were uncommon. Secondary surgery was necessary 7.3% of the time for complications/adverse events (excluding graft reinjury or revisions) within the first 2 years. Level 1 (therapeutic studies

  10. Neo-glans reconstruction for penile cancer: Description of the primary technique using autologous testicular tunica vaginalis graft

    Directory of Open Access Journals (Sweden)

    Peter Weibl

    2018-06-01

    Neo-glans reconstruction with TV coverage may be another promising alternative, which certainly requires further evaluation. We believe that the donor-site associated morbidity is minimal when compared to other harvesting sites. However, this is just an assumption, because direct comparison data on grafting techniques and neo-glans reconstruction are not available. Nevertheless, we think that for re-do procedures a standardised approach using a STSG technique should be the treatment method of choice.

  11. A randomized comparison of the Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial: One-year angiographic results and mid-term clinical outcomes.

    Science.gov (United States)

    Kim, Ki-Bong; Hwang, Ho Young; Hahn, Seokyung; Kim, Jun Sung; Oh, Se Jin

    2014-09-01

    The Saphenous Vein Versus Right Internal Thoracic Artery as a Y-Composite Graft (SAVE RITA) trial was designed to evaluate the noninferiority of the saphenous vein (SV) compared with the right internal thoracic artery ([R]ITA) used as a Y-composite graft. A total of 224 patients who had undergone off-pump revascularization for multivessel coronary artery disease using the SV or RITA as a Y-composite graft based on the in situ left ITA were assigned randomly to the SV Y-composite graft (SV group, n = 112) or free RITA Y-composite graft (RITA group, n = 112). The primary endpoint was the 1-year angiographic patency rate of the second limb conduits (SV or RITA). Postoperative 1-year coronary angiograms were performed in 215 patients (SV group, 108; RITA group, 107). The overall graft patency rate was 97.4% (745 of 765) at 1 year (97.9% in the SV group vs 96.9% in the RITA group, P = .362). The primary endpoint of the study, the 1-year patency rate of the SV composite grafts, was 97.1% (238 of 245) and was noninferior to that of the RITA composite grafts (97.1% [198 of 204]) with a 95% lower confidence limit of -2.6% (P RITA composite grafts in terms of the 1-year angiographic patency rates. Copyright © 2014 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  12. Accuracy of using computer-aided rapid prototyping templates for mandible reconstruction with an iliac crest graft

    Science.gov (United States)

    2014-01-01

    Background This study aimed to evaluate the accuracy of surgical outcomes in free iliac crest mandibular reconstructions that were carried out with virtual surgical plans and rapid prototyping templates. Methods This study evaluated eight patients who underwent mandibular osteotomy and reconstruction with free iliac crest grafts using virtual surgical planning and designed guiding templates. Operations were performed using the prefabricated guiding templates. Postoperative three-dimensional computer models were overlaid and compared with the preoperatively designed models in the same coordinate system. Results Compared to the virtual osteotomy, the mean error of distance of the actual mandibular osteotomy was 2.06 ± 0.86 mm. When compared to the virtual harvested grafts, the mean error volume of the actual harvested grafts was 1412.22 ± 439.24 mm3 (9.12% ± 2.84%). The mean error between the volume of the actual harvested grafts and the shaped grafts was 2094.35 ± 929.12 mm3 (12.40% ± 5.50%). Conclusions The use of computer-aided rapid prototyping templates for virtual surgical planning appears to positively influence the accuracy of mandibular reconstruction. PMID:24957053

  13. Postoperative irradiation after reconstructive surgery: comparative study of radiosensitivity between free-skin grafts and skin flaps

    International Nuclear Information System (INIS)

    Sumi, Y.; Ueda, M.; Kaneda, T.; Oka, T.; Torii, S.; Sakuma, S.

    1984-01-01

    Radiation effects after reconstructive surgery (free-skin grafts and skin flaps) were studied in the rat, and the optimum time for irradiation was determined. The radiosensitivity of both free-skin grafts and skin flaps showed the same trend depending on time of irradiation after operation. The grafts or flaps irradiated in the hypervascular stage showed severe reactions to irradiation, whereas those irradiated in the hypovascular stage showed milder reactions in gross and microangiographic observation. Vascular damage should be given primary consideration when deciding the proper time for irradiation after reconstructive surgery. In general, free-skin grafts showed more severe reactions than skin flaps, especially in the grafts irradiated in the early stage after operation. The experimental results of this study cannot be readily transferred to a clinical setting, but they suggest that postoperative irradiation could be begun 3 to 4 weeks after operation with respect to graft or flap survival, and the results of the clinical cases almost coincide with these experimental results

  14. A composed graft for subclavian artery reconstruction in case of redo surgery for aortic coarctation

    Directory of Open Access Journals (Sweden)

    Fabrizio Sansone

    2013-01-01

    Full Text Available We report the case of a 66-year-old woman admitted to the intensive care unit (ICU for ongoing dyspnea and hemoptoe. She was operated upon in 1979 for aortic coarctation by the interposition of a 14 mm Dacron prosthesis from the left subclavian artery to descending aorta. Clinical evaluation performed over the years was normal with no signs of cardiac failure or prosthesis malfunctioning. The computed tomography scans (CT showed a progressive increase of the descending aorta diameters and the onset of a pseudo-aneurysm of 50 mm in diameter. Patient was re-operated through a median sternotomy enlarged by a left thoracotomy and intra-operative findings revealed the pseudo-aneurysm originating from a dehiscence of the proximal suture. In order to allow a safe reconstruction of the dilated subclavian artery, a T-shaped composed graft was confectioned and then sutured to the descending aorta and the subclavian artery, respectively. Post-operative course was uneventful and three months CT scan showed a normal position of the composed graft.

  15. Solitary haemangioma of the shaft of long bones: resection and reconstruction with autologous bone graft.

    Science.gov (United States)

    Li, Zhaoxu; Tang, Jicun; Ye, Zhaoming

    2013-04-01

    Bone haemangiomas are uncommon lesions, occurring in the skull or spine. A solitary haemangioma in the diaphysis of a long bone is rare. We retrospectively investigated six patients who presented with a solitary haemangioma in a long bone diaphysis. After segmental bone resection, the bone defect was replaced by a bone autograft. Patients were reviewed clinically and with radiographs. The mean follow-up was 6 years (range : 1-20 years). At the time of latest follow-up, no patient had a recurrence. Postoperative complications were one wound necrosis and one superficial wound infection. Union of the gap filling graft with the host bone was achieved in all patients at an average of 4 months (range: 3-8 months). The average Musculoskeletal Tumor Society functional score was 77% (range: 53%-90%) of normal at 6 months postoperatively, and 97% (range: 95%-99%) at the last follow-up evaluation. Segmental resection for solitary haemangioma and reconstruction with autologous bone graft can be considered as a suitable treatment option.

  16. One stage revision single-bundle anterior cruciate ligament reconstruction with impacted morselized bone graft following a failed double-bundle reconstruction

    Directory of Open Access Journals (Sweden)

    Ho Jong Ra

    2017-01-01

    Full Text Available Although double-bundle anterior cruciate ligament (ACL reconstruction has theoretical benefits such as more accurate reproduction of ACL anatomy, it is technically more demanding surgery. This report describes the case of a one stage revision single-bundle ACL reconstruction after primary double-bundle ACL reconstruction. A professional dancer had an ACL previously reconstructed with a double-bundle technique, but the femoral tunnels were malpositioned resulting in residual laxity and rotational instability. The previous femoral tunnel positions were vertical and widened. The previous vertical tunnels were filled with impacted bone graft and a revision single-bundle ACL reconstruction was performed via the new femoral tunnel with a 2 O'clock position between the previous two tunnels. After 10 months of postoperative rehabilitation, the patient returned to professional dancing with sound bony union and without any residual instability.

  17. Modified Weaver-Dunn Procedure Versus The Use of Semitendinosus Autogenous Tendon Graft for Acromioclavicular Joint Reconstruction.

    Science.gov (United States)

    Hegazy, Galal; Safwat, Hesham; Seddik, Mahmoud; Al-Shal, Ehab A; Al-Sebai, Ibrahim; Negm, Mohame

    2016-01-01

    The optimal operative method for acromioclavicular joint reconstruction remains controversial. The modified Weaver-Dunn method is one of the most popular methods. Anatomic reconstruction of coracoclavicular ligaments with autogenous tendon grafts, widely used in treating chronic acromioclavicular joint instability, reportedly diminishes pain, eliminates sequelae, and improves function as well as strength. To compare clinical and radiologic outcomes between a modified Weaver-Dunn procedure and an anatomic coracoclavicular ligaments reconstruction technique using autogenous semitendinosus tendon graft. Twenty patients (mean age, 39 years) with painful, chronic Rockwood type III acromioclavicular joint dislocations were subjected to surgical reconstruction. In ten patients, a modified Weaver-Dunn procedure was performed, in the other ten patients; autogenous semitendinosus tendon graft was used. The mean time between injury and the index procedure was 18 month (range from 9 - 28). Clinical evaluation was performed using the Oxford Shoulder Score and Nottingham Clavicle Score after a mean follow-up time of 27.8 months. Preoperative and postoperative radiographs were compared. In the Weaver-Dunn group the Oxford Shoulder Score improved from 25±4 to 40±2 points. While the Nottingham Clavicle Score increased from 48±7 to 84±11. In semitendinosus tendon graft group, the Oxford Shoulder Score improved from 25±3 points to 50±2 points and the Nottingham Clavicle Score from 48±8 points to 95±8, respectively. Acromioclavicular joint reconstruction using the semitendinosus tendon graft achieved better Oxford Shoulder Score and Nottingham Clavicle Score compared to the modified Weaver-Dunn procedure.

  18. Prevention of one-year vein-graft occlusion after aortocoronary-bypass surgery: a comparison of low-dose aspirin, low-dose aspirin plus dipyridamole, and oral anticoagulants. The CABADAS Research Group of the Interuniversity Cardiology Institute of The Netherlands

    NARCIS (Netherlands)

    van der Meer, J.; Hillege, H. L.; Kootstra, G. J.; Ascoop, C. A.; Mulder, B. J.; Pfisterer, M.; van Gilst, W. H.; Lie, K. I.

    1993-01-01

    Aspirin, alone or in combination with dipyridamole, is known to prevent occlusion of aortocoronary vein grafts. The benefit of dipyridamole in addition to aspirin remains controversial, and the efficacy and safety of oral anticoagulants for prevention of vein-graft occlusion have not been

  19. Polyurethane Foam Wound Dressing Technique for Areola Skin Graft Stabilization and Nipple Protection After Nipple-Areola Reconstruction.

    Science.gov (United States)

    Satake, Toshihiko; Muto, Mayu; Nagashima, Yu; Haga, Shoko; Homma, Yuki; Nakasone, Reiko; Kadokura, Marina; Kou, Seiko; Fujimoto, Hiroshi; Maegawa, Jiro

    2018-04-01

    We describe a new wound management technique using a soft dressing material to stabilize the areola skin graft and protect the nipple after nipple-areola reconstruction at the final stage of breast reconstruction. We introduced a center-fenestrated multilayered hydrocellular polyurethane foam dressing material that provides adequate pressure and retains a moist environment for a smooth skin graft "take." Moreover, the reconstructed nipple can be monitored at any time through the fenestrated window for adequate blood circulation. Altogether, this simple and inexpensive wound dressing technique improves the clinical outcome. Level of Evidence IV This journal requires that authors assign a level of evidence to each article. For a full description of these Evidence-Based Medicine ratings, please refer to Table of Contents or the online Instructions to Authors www.springer.com/00266 .

  20. Panorama of Reconstruction of Skull Base Defects: From Traditional Open to Endonasal Endoscopic Approaches, from Free Grafts to Microvascular Flaps

    Science.gov (United States)

    Reyes, Camilo; Mason, Eric; Solares, C. Arturo

    2014-01-01

    Introduction A substantial body of literature has been devoted to the distinct characteristics and surgical options to repair the skull base. However, the skull base is an anatomically challenging location that requires a three-dimensional reconstruction approach. Furthermore, advances in endoscopic skull base surgery encompass a wide range of surgical pathology, from benign tumors to sinonasal cancer. This has resulted in the creation of wide defects that yield a new challenge in skull base reconstruction. Progress in technology and imaging has made this approach an internationally accepted method to repair these defects. Objectives Discuss historical developments and flaps available for skull base reconstruction. Data Synthesis Free grafts in skull base reconstruction are a viable option in small defects and low-flow leaks. Vascularized flaps pose a distinct advantage in large defects and high-flow leaks. When open techniques are used, free flap reconstruction techniques are often necessary to repair large entry wound defects. Conclusions Reconstruction of skull base defects requires a thorough knowledge of surgical anatomy, disease, and patient risk factors associated with high-flow cerebrospinal fluid leaks. Various reconstruction techniques are available, from free tissue grafting to vascularized flaps. Possible complications that can befall after these procedures need to be considered. Although endonasal techniques are being used with increasing frequency, open techniques are still necessary in selected cases. PMID:25992142

  1. Comparing the Efficacy of Triple Nerve Transfers with Nerve Graft Reconstruction in Upper Trunk Obstetric Brachial Plexus Injury.

    Science.gov (United States)

    O'Grady, Kathleen M; Power, Hollie A; Olson, Jaret L; Morhart, Michael J; Harrop, A Robertson; Watt, M Joe; Chan, K Ming

    2017-10-01

    Upper trunk obstetric brachial plexus injury can cause profound shoulder and elbow dysfunction. Although neuroma excision with interpositional sural nerve grafting is the current gold standard, distal nerve transfers have a number of potential advantages. The goal of this study was to compare the clinical outcomes and health care costs between nerve grafting and distal nerve transfers in children with upper trunk obstetric brachial plexus injury. In this prospective cohort study, children who underwent triple nerve transfers were followed with the Active Movement Scale for 2 years. Their outcomes were compared to those of children who underwent nerve graft reconstruction. To assess health care use, a cost analysis was also performed. Twelve patients who underwent nerve grafting were compared to 14 patients who underwent triple nerve transfers. Both groups had similar baseline characteristics and showed improved shoulder and elbow function following surgery. However, the nerve transfer group displayed significantly greater improvement in shoulder external rotation and forearm supination 2 years after surgery (p The operative time and length of hospital stay were significantly lower (p the overall cost was approximately 50 percent less in the nerve transfer group. Triple nerve transfer for upper trunk obstetric brachial plexus injury is a feasible option, with better functional shoulder external rotation and forearm supination, faster recovery, and lower cost compared with traditional nerve graft reconstruction. Therapeutic, II.

  2. Do peak torque angles of muscles change following anterior cruciate ligament reconstruction using hamstring or patellar tendon graft?

    Science.gov (United States)

    Yosmaoğlu, Hayri Baran; Baltacı, Gül; Sönmezer, Emel; Özer, Hamza; Doğan, Deha

    2017-12-01

    This study aims to compare the effects of anterior cruciate ligament (ACL) reconstruction using autogenous hamstring or patellar tendon graft on the peak torque angle. The study included 132 patients (103 males, 29 females; mean age 29±9 year) who were performed ACL reconstruction with autogenous hamstring or patellar tendon graft. The peak torque angles in the quadriceps and hamstring muscles were recorded using an isokinetic dynamometer. Angle of peak knee flexion torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the hamstring tendon group. Angle of peak knee extension torque occurred significantly earlier within the range of motion on the operated side than nonoperated side at 180°/second in the patellar tendon group. There were no statistically significant differences in the flexion and extension peak torque angles between the operated and nonoperated knees at 60°/second in both groups. The angle of peak torque at relatively high angular velocities is affected after ACL reconstruction in patients with hamstring or patellar tendon grafts. The graft donor site directly influences this parameter. This finding may be important for clinicians in terms of preventing re-injury.

  3. Anterior versus posterior approach in reconstruction of infected nonunion of the tibia using the vascularized fibular graft: potentialities and limitations.

    Science.gov (United States)

    Amr, Sherif M; El-Mofty, Aly O; Amin, Sherif N

    2002-01-01

    The potentialities, limitations, and technical pitfalls of the vascularized fibular grafting in infected nonunions of the tibia are outlined on the basis of 14 patients approached anteriorly or posteriorly. An infected nonunion of the tibia together with a large exposed area over the shin of the tibia is better approached anteriorly. The anastomosis is placed in an end-to-end or end-to-side fashion onto the anterior tibial vessels. To locate the site of the nonunion, the tibialis anterior muscle should be retracted laterally and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. All the scarred skin over the anterior tibia should be excised, because it becomes devitalized as a result of the exposure. To cover the exposed area, the fibula has to be harvested with a large skin paddle, incorporating the first septocutaneous branch originating from the peroneal vessels before they gain the upper end of the flexor hallucis longus muscle. A disadvantage of harvesting the free fibula together with a skin paddle is that its pedicle is short. The skin paddle lies at the antimesenteric border of the graft, the site of incising and stripping the periosteum. In addition, it has to be sutured to the skin at the recipient site, so the soft tissues (together with the peroneal vessels), cannot be stripped off the graft to prolong its pedicle. Vein grafts should be resorted to, if the pedicle does not reach a healthy segment of the anterior tibial vessels. Defects with limited exposed areas of skin, especially in questionable patency of the vessels of the leg, require primarily a fibula with a long pedicle that could easily reach the popliteal vessels and are thus better approached posteriorly. In this approach, the site of the nonunion is exposed medial to the flexor digitorum muscle and the proximal and distal ends of the site of the nonunion debrided up to healthy bleeding bone. No attempt should be made to strip the scarred skin off

  4. Assessment of rotatory instability after anterior cruciate ligament reconstruction with a bone-patellar tendon-bone graft

    International Nuclear Information System (INIS)

    Tashiro, Yasutaka; Okazaki, Ken; Miura, Hiromasa

    2010-01-01

    Anatomically oriented anterior cruciate ligament (ACL) reconstruction has been advocated recently, but its effect on rotatory instability remains to be cleared objectively. The purpose of this study was to quantitatively evaluate rotatory instability in ACL reconstructed knees with a bone-patellar tendon-bone (BTB) graft using an open MRI system. Eighteen subjects underwent arthroscopic ACL reconstruction with a BTB graft. The tibial tunnel was placed in the center of the ACL footprint. The femoral tunnel was drilled transtibially at the 10:00 to 10:30-o'clock position for the right knees. Subjects were examined using a Slocum anterolateral rotatory instability test in open MRI. Anterior tibial translation was measured at the medial and lateral compartments by evaluating sagittal images. Anterior knee stability was evaluated using the KT-2000 arthrometer. The clinical knee function was assessed with the Lysholm and Tegner scoring scales before and after the surgery. Side-to-side differences of anterolateral tibial translation was 0.1 mm. Side-to-side difference on KT-2000 arthrometer measurement was 1.8 mm. The Lysholm score improved to 96 and the latest Tegner score reached substantially the preinjury level. ACL reconstruction with a BTB graft was successful in restoring rotatory stability as well as anterior stability and knee function. (author)

  5. Comparative analysis of use of porous orbital implant with mucus membrane graft and dermis fat graft as a primary procedure in reconstruction of severely contracted socket

    Directory of Open Access Journals (Sweden)

    Kasturi Bhattacharjee

    2014-01-01

    Full Text Available Purpose: The purpose of our study is to present a surgical technique of primary porous orbital ball implantation with overlying mucus membrane graft (MMG for reconstruction of severely contracted socket and to evaluate prosthesis retention and motility in comparison to dermis fat graft (DFG. Study Design: Prospective comparative study. Materials and Methods: A total of 24 patients of severe socket contracture (Grade 2-4 Krishna′s classification were subdivided into two groups, 12 patients in each group. In Group I, DFG have been used for reconstruction. In Group II, porous polyethylene implant with MMG has been used as a primary procedure for socket reconstruction. In Group I DFG was carried out in usual procedure. In case of Group II, vascularized scar tissues were separated 360° and were fashioned into four strips. A scleral capped porous polyethylene implant was placed in the intraconal space and four strips of scar tissue were secured to the scleral cap and extended part overlapped the implant to make a twofold barrier between the implant and MMG. Patients were followed-up as per prefixed proforma. Prosthesis motility and retention between the two groups were measured. Results: In Group I, four patients had recurrence of contracture with fall out of prosthesis. In Group II stable reconstruction was achieved in all the patients. In terms of prosthesis motility, maximum in Group I was 39.2% and Group II, was 59.3%. The difference in prosthesis retention (P = 0.001 and motility (P = 0.004 between the two groups was significant. Conclusion: Primary socket reconstruction with porous orbital implant and MMG for severe socket contracture is an effective method in terms of prosthesis motility and prosthesis retention.

  6. Biomechanical findings in rats undergoing fascial reconstruction with graft materials suggested as an alternative to polypropylene.

    Science.gov (United States)

    Konstantinovic, M L; Ozog, Y; Spelzini, F; Pottier, C; De Ridder, D; Deprest, J

    2010-03-01

    Graft materials used for pelvic floor reinforcement should still be considered as investigational and, therefore, evaluated experimentally and within clinical trials. The present report describes our biomechanical findings in rats implanted with selected novel implant materials, which in recent years have been suggested as alternatives to plain polypropylene (PP) meshes. Full thickness abdominal wall defects were primarily repaired by the implant of interest. Experiments involved eight different implant materials: two partly degradable synthetic implants, that is, a hybrid of polyglactin 910 with PP (Vypro II) and collagen coated PP (Pelvitex); two non-cross linked (Surgisis, InteXēn LP) and two cross-linked materials (Pelvicol, Pelvisoft) and two porous modifications of InteXēn LP and Pelvicol implants. At different time points (7, 14, 30, and 90 days), the implants and surrounding host tissue (explant) were harvested and tensiometry was performed. Tensile strength and location of breakage were recorded. In general resorbable non-cross linked collagen matrices and porous materials were weaker after 90 days; similar behavior was seen for implant materials alone and their construction with the surrounding native tissue. Both non-porous and porous modification of InteXēn LP appeared at 90 days as a very thin layer of collagen that was two-thirds, respectively one-third of the initial thickness. In experimental conditions, sufficient strength was obtained only after 3 months, and PP containing constructs appeared as the strongest though reconstruction with Pelvicol showed comparable outcomes. Lower values for strength of non-cross linked and porous collagen materials are questioning their efficacy for pelvic floor reconstruction. (c) 2009 Wiley-Liss, Inc.

  7. Ultrastructural investigations for reducing endothelial cell damage of vein grafts during CABG-operation and practical consequences.

    Science.gov (United States)

    Hickethier, T; Dämmrich, J; Silber, R E; Finster, S; Elert, O

    1999-02-01

    In the present study the influence of different storage solutions on endothelial integrity or damage was investigated with direct methods particularly with transmission electron microscopy (TEM), scanning electron microscopy (SEM) and immunohistochemistry. Saphenous vein segments of 10 cm in length were taken surgically from 6 male CABG-patients (aged 60-70) under standardized conditions. Each vein segment was cut into rings, which were incubated at room temperature for 45 minutes in different storage solutions, particularly in 0.9% sodium chloride solution and in buffered solution (M 199) with 5% human serum albumin respectively. Then, the vein segments were fixed in 3.5% glutaraldehyde and prepared for scanning and transmission electron microscopy to evaluate the endothelial damage. In addition, immunohistochemical staining (CD34, PECAM and Factor VIII) was performed. When using 0.9% sodium chloride solution, the SEM-examination revealed that 55% of the cell population was destroyed. In comparison to these findings only 26% of the endothelial cell population was damaged when the venous segment was stored in buffered solution with 5% albumin (p<0.01). In immunohistochemistry (CD34, PECAM, Factor VIII) these findings were supported. This study demonstrates the importance of storage solutions in regard to endothelial integrity. For best preservation of endothelium it is necessary to modify conventional storage methods. So, storage in buffered solution with albumin has shown much better endothelial cell preservation compared with physiological saline which might reduce the obliteration rate of CABG in future.

  8. Bracing can partially limit tibial rotation during stressful activities after anterior crucial ligament reconstruction with a hamstring graft.

    Science.gov (United States)

    Giotis, D; Paschos, N K; Zampeli, F; Pappas, E; Mitsionis, G; Georgoulis, A D

    2016-09-01

    Hamstring graft has substantial differences with BPTB graft regarding initial mechanical strength, healing sequence, and vascularization, which may imply that a different approach during rehabilitation period is required. The purpose of this study was to investigate the influence of knee bracing on tibial rotation in ACL-reconstructed patients with a hamstring autograft during high loading activities. The hypothesis was that there would be a decrease in tibial rotation in the ACL-reconstructed braced knee as compared to the unbraced knee. Twenty male patients having undergone unilateral ACL reconstruction with a semitendinosus/gracilis autograft were assessed. Kinematic data were collected with an eight-camera optoelectronic system during two stressful tasks: (1) descending from a stair and subsequent pivoting; and (2) landing from a platform and subsequent pivoting. In each patient, three different experimental conditions were evaluated: (A) wearing a prophylactic brace (braced condition); (B) wearing a patellofemoral brace (sleeved condition); (C) without brace (unbraced condition). The intact knee without brace served as a control. Tibial rotation was significantly lower in the intact knee compared to all three conditions of the ACL-reconstructed knee (P≤0.01 for both tasks). Presence of a brace or sleeve resulted in lower tibial rotation than in the unbraced condition (p=0.003 for descending/pivot and P=0.0004 for landing/pivot). The braced condition resulted in lower rotation than the sleeved condition for descending/pivoting (P=0.031) while no differences were found for landing/pivoting (P=0.230). Knee bracing limited the excessive tibial rotation during pivoting under high loading activities in ACL-reconstructed knees with a hamstring graft. This partial restoration of normal kinematics may have a potential beneficial effect in patients recovering from ACL reconstruction with a hamstring autograft. Level III, case-control therapeutic study. Copyright

  9. Endolymphatic Thoracic Duct Stent-Graft Reconstruction for Chylothorax: Approach, Technical Success, Safety, and Short-term Outcomes.

    Science.gov (United States)

    Srinivasa, Rajiv N; Chick, Jeffrey Forris Beecham; Hage, Anthony N; Gemmete, Joseph J; Murrey, Douglas C; Srinivasa, Ravi N

    2018-04-01

    To report approach, technical success, safety, and short-term outcomes of thoracic duct stent-graft reconstruction for the treatment of chylothorax. Two patients, 1 (50%) male and 1 (50%) female, with mean age of 38 years (range: 16-59 years) underwent endolymphatic thoracic duct stent-graft reconstruction between September 2016 and July 2017. Patients had radiographic left-sided chylothoraces (n = 2) from idiopathic causes (n = 1) and heart transplantation (n = 1). In both (100%) patients, antegrade lymphatic access was used to opacify the thoracic duct after which retrograde access was used for thoracic duct stent-graft placement. Pelvic lymphangiography technical success, antegrade cisterna chyli cannulation technical success, thoracic duct opacification technical success, retrograde thoracic duct access technical success, thoracic duct stent-graft reconstruction technical success, ethiodized oil volume, contrast volume, estimated blood loss, procedure time, fluoroscopy time, radiation dose, clinical success, complications, deaths, and follow-up were recorded. Pelvic lymphangiography, antegrade cisterna chyli cannulation, thoracic duct opacification, retrograde thoracic duct access, and thoracic duct stent-graft reconstruction were technically successful in both (100%) patients. Mean ethiodized oil volume was 8 mL (range: 5-10 mL). Mean contrast volume was 13 mL (range: 5-20 mL). Mean estimated blood loss was 13 mL (range: 10-15 mL). Mean fluoroscopy time was 50.4 min (range: 31.2-69.7 min). Mean dose area product and reference air kerma were 954.4 μGmy 2 (range: 701-1,208 μGmy 2 ) and 83.5 mGy (range: 59-108 mGy), respectively. Chylothorax resolved in both (100%) patients. There were no minor or major complications directly related to the procedure. Thoracic duct stent-graft reconstruction may be a technically successful and safe alternative to thoracic duct embolization, disruption, and surgical ligation for the treatment of chylothorax

  10. Aneurismas múltiplos de pontes aorto-coronárias de veia safena com ruptura fatal Multiple aneurysms of aortocoronary saphenous vein grafts with fatal rupture

    Directory of Open Access Journals (Sweden)

    Fábio R. Távora

    2007-05-01

    Full Text Available Aneurismas de pontes aorto-coronárias de veia safena são eventos raros, usualmente assintomáticos e detectados de forma incidental. Rupturas espontâneas de pontes de safena são raras, havendo poucos dados radiológicos disponíveis na literatura. Relatamos o caso de um senhor de 39 anos internado com hematêmese dez anos depois de ter sido submetido a cirurgia de revascularização miocárdica. Imagens tomográficas mostraram três aneurismas nas pontes de safena, mas o exame não detectou ruptura. O paciente veio a falecer e a necropsia revelou que a causa do óbito havia sido ruptura de aneurisma de pontes de safena. Esse caso ilustra a necessidade de tratamento agressivo de aneurismas sintomáticos de pontes coronarianas.Aortocoronary saphenous vein graft (SVG aneurysms are rare, and are usually asymptomatic and detected incidentally. Spontaneous rupture of SVG is rare and imaging data are few. We report on a 39-year old man who was admitted to the hospital with hematemesis 10 years after aortocoronary bypass surgery. CT images revealed 3 aortocoronary SVG aneurysms, but failed to detect any rupture. His subsequent death due to rupture of SVG aneurysm was documented at autopsy, illustrating the need for aggressive treatment of symptomatic coronary graft aneurysms.

  11. Excision of Oral Submucous Fibrosis and Reconstruction with Full Thickness Skin Graft: A Case Study and Review of the Literature

    Science.gov (United States)

    Alshadwi, Ahmad; Bhatia, Ishwar

    2012-01-01

    Oral submucous fibrosis is a chronic debilitating disease characterized by gradually increasing fibrosis of the oral cavity and pharynx, mainly the buccal mucosa, resulting in trismus. The highest incidence of oral submucous fibrosis is seen in South India due to various deleterious habits. In spite of the numerous medical modalities employed in the management of oral submucous fibrosis, occasionally surgical intervention becomes inevitable. Various surgical approaches have been used to reconstruct the surgical defects following excision of fibrous bands. Full thickness skin grafts have been described in the literature with variable outcomes. In the present study a 38-year-old male presented with severe oral submucous fibrosis of the buccal mucosa, which was successfully treated and reconstructed using full thickness skin graft with stable functional result after one year of treatment. An integrated review of the literature regarding etiology, histopathology, diagnostic, and treatment modalities of the disease follows. PMID:23304568

  12. [Fusion of reconstructed titanic plate, vertebral pedical screws and autogenous granulated cancellous bone graft in posterior occipitocervical region].

    Science.gov (United States)

    Zhong, Dejun; Song, Yueming

    2006-08-01

    To explore the technique of fusing the reconstructed titanic plate, the C2 pedical screws, and the autogenous granulated cancellous bone graft in the occipitocervical region. From April 2002 to January 2005, 19 patients aged 31-67 years with occipitocervical instability underwent the occipitocervical fusion using the reconstructed plate, C2 pedical screws, and autogenous granulated cancellous bone graft. Of the patients, 8 had complex occipitocervical deformity, 8 had old atlantoaxial fracture and dislocation, 2 had rheumatoid arthritis and anterior dislocation of the atlantoaxial joint, and 1 had cancer of the deltoid process of the axis. No complication occurred during and after operation. The follow-up for an average of 16 months in 19 patients showed that all the patients achieved solid bony fusion in the occipitocervical region. There was no broken plate, broken screw, looseness of the internal fixation or neurovascular injury. The fixation of the C2 pedical screws with the reconstructed titanic plate is reliable, the insertion is easy, and the autogenous granulated cancellous bone graft has a high fusion rate, thus resulting in a satisfactory effect in the occipitocervical fusion.

  13. Skin Graft

    OpenAIRE

    Shimizu, Ruka; Kishi, Kazuo

    2012-01-01

    Skin graft is one of the most indispensable techniques in plastic surgery and dermatology. Skin grafts are used in a variety of clinical situations, such as traumatic wounds, defects after oncologic resection, burn reconstruction, scar contracture release, congenital skin deficiencies, hair restoration, vitiligo, and nipple-areola reconstruction. Skin grafts are generally avoided in the management of more complex wounds. Conditions with deep spaces and exposed bones normally require the use o...

  14. Biomechanical properties of patellar and hamstring graft tibial fixation techniques in anterior cruciate ligament reconstruction: experimental study with roentgen stereometric analysis.

    Science.gov (United States)

    Adam, Frank; Pape, Dietrich; Schiel, Karin; Steimer, Oliver; Kohn, Dieter; Rupp, Stefan

    2004-01-01

    Reliable fixation of the soft hamstring grafts in ACL reconstruction has been reported as problematic. The biomechanical properties of patellar tendon (PT) grafts fixed with biodegradable screws (PTBS) are superior compared to quadrupled hamstring grafts fixed with BioScrew (HBS) or Suture-Disc fixation (HSD). Controlled laboratory study with roentgen stereometric analysis (RSA). Ten porcine specimens were prepared for each group. In the PT group, the bone plugs were fixed with a 7 x 25 mm BioScrew. In the hamstring group, four-stranded tendon grafts were anchored within a tibial tunnel of 8 mm diameter either with a 7 x 25 mm BioScrew or eight polyester sutures knotted over a Suture-Disc. The grafts were loaded stepwise, and micromotion of the graft inside the tibial tunnel was measured with RSA. Hamstring grafts failed at lower loads (HBS: 536 N, HSD 445 N) than the PTBS grafts (658 N). Stiffness in the PTBS group was much greater compared to the hamstring groups (3500 N/mm versus HBS = 517 N/mm and HSD = 111 N/mm). Irreversible graft motion after graft loading with 200 N was measured at 0.03 mm (PTBS), 0.38mm (HBS), and 1.85mm (HSD). Elasticity for the HSD fixation was measured at 0.67 mm at 100 N and 1.32 mm at 200 N load. Hamstring graft fixation with BioScrew and Suture-Disc displayed less stiffness and early graft motion compared to PTBS fixation. Screw fixation of tendon grafts is superior to Suture-Disc fixation with linkage material since it offers greater stiffness and less graft motion inside the tibial tunnel. Our results revealed graft motion for hamstring fixation with screw or linkage material at loads that occur during rehabilitation. This, in turn, may lead to graft laxity.

  15. Reconstruction of irradiated mandible after segmental resection of osteoradionecrosis-a technique employing a microvascular latissimus dorsi flap and subsequent particulate iliac bone grafting

    DEFF Research Database (Denmark)

    Hillerup, Soren; Elberg, Jens Jorgen; Thorn, Jens Jorgen

    2014-01-01

    patients had a subsequent bone grafting from the posterior ileum for repair of defects up to 14 cm length. Three patients had no bone graft for various reasons. In three patients dental rehabilitation was achieved with implant supported prosthodontic appliances. Ten patients met the success criteria......, and the defect site was primed with a LD musculocutaneous flap wrapped around the reconstruction plate to bring in vascularized tissue and optimize healing conditions for a subsequent particulate iliac free bone graft reconstruction. The management of defect closure was successful in all 15 patients. Twelve...

  16. Reconstruction of the Shallow Acetabulum With a Combination of Autologous Bulk and Impaction Bone Grafting Fixed by Cement.

    Science.gov (United States)

    Maruyama, Masaaki; Wakabayashi, Shinji; Ota, Hiroshi; Tensho, Keiji

    2017-02-01

    Acetabular bone deficiency, especially proximal and lateral deficiency, is a difficult technical problem during primary total hip arthroplasty (THA) in developmental dysplasia of the hip (DDH). We report a new reconstruction method using a medial-reduced cemented socket and additional bulk bone in conjunction with impaction morselized bone grafting (additional bulk bone grafting method). In a population of patients with acetabular dysplasia undergoing THA using a medial-reduced cemented socket and additional bulk bone with impacted morselized bone grafting, we evaluated (1) the radiographic appearance of bone graft; (2) the proportion of cups that developed loosening and subsequent revision; and (3) clinical results (outcome scores and complications). Forty percent of 330 THAs for DDH performed at one center between 1999 and 2009 were defined as shallow dysplastic hips. The additional bulk bone grafting method was performed on 102 THAs with shallow acetabulum (31% for DDH) at one center between 1999 and 2009. We used this approach and technique for shallow acetabuli when a cup protruded from the lateral acetabular edge in preoperative templating. The other 132 dysplastic hips without bone grafting had THA performed at the same periods and served as a control. Acetabuli were defined as shallow when the depth was less than or equal to one-fifth of the pelvic height (cranial-caudal length on radiograph). The additional bulk bone grafting technique was as follows: the resected femoral head was sectioned at 1 to 2 cm thickness, and a suitable size of the bulk bone graft was placed on the lateral iliac cortex and fixed by poly-L-lactate absorbable screws. Autologous impaction morselized bone grafting, with or without hydroxyapatite granules, was performed along with the implantation of a medial-reduced cemented socket. We defined an "incorporated" graft as remodeling and trabeculation including rounding off of the protruding edge of a graft beyond the socket

  17. Combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in patients with congenital atresia of cervix.

    Science.gov (United States)

    Zhang, Xuyin; Han, Tiantian; Ding, Jingxin; Hua, Keqin

    2015-01-01

    The aim of this study was to introduce a new technique which is combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in patients with congenital atresia of cervix and to evaluate the feasibility and the safety of it. This is a prospective observational study of 10 patients with congenital atresia of cervix who underwent combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft for cervicovaginal reconstruction from February 2013 to August 2014 in our hospital. All of the surgical procedures were carried out by the same operation team. Patient data were collected including operating time, estimated blood loss, hospital stay post-surgery, complications, total cost, and median vaginal length at 3 month, resumption of menstruation, vaginal stenosis and stricture of the cervix postoperatively. The operative procedure lasted 237±46 (175-380) min. The estimated blood loss was 160±76 (50-300) ml. The hospital stay post-surgery was 12±2 (9-18) days. None of the patients had complications or required a blood transfusion. The mean total cost was $3352±1025. The average vaginal length at 3 month was 8.3±1.1 (8-10) cm. All patients had resumption of menstruation. The patients were followed for a mean of 5±2 (1-10) months. Cervical or vaginal stenosis did not occur in any of the patients. Our experiences of combined laparoscopic and vaginal cervicovaginal reconstruction using split thickness skin graft in10 patients with congenital atresia of cervix were positive, with successful results and without complications, and cervical or vaginal stenosis.

  18. Posterolateral Corner Reconstruction using the Anatomical Two-Tailed Graft Technique: Clinical Outcomes in the Multiligament Injured Knee.

    Science.gov (United States)

    Woodmass, Jarret M; Sanders, Thomas L; Johnson, Nick R; Wu, Isabella T; Krych, Aaron J; Stuart, Michael J; Levy, Bruce A

    2018-02-14

    Injury to the posterolateral corner (PLC) of the knee can lead to both varus and rotational instability. Multiple PLC reconstruction techniques have been described, including one-tailed graft (fibula-based constructs) or two-tailed graft (combined fibula- and tibia-based constructs). The purpose of our study was to evaluate the clinical outcomes of anatomical two-tailed graft reconstruction of the PLC in the setting of multiligament knee injuries (MKLIs) with grade III varus instability. Patients were identified through a prospective MLKI database between 2004 and 2013. Patients who received fibular collateral ligament and PLC reconstructions using a two-tailed graft and had a minimum follow-up of 2 years were included. Patients were assessed for clinical laxity grade, range of motion, and functional outcomes using Lysholm and International Knee Documentation Committee (IKDC) scores. Twenty patients (16 male, 4 female) with a mean age of 30.7 (range: 16-52) and a mean follow-up of 52.2 months (range: 24-93 months) were included. Knee dislocation (KD) grades included: 4 KD-1, 10 KD 3-L, 5 KD-4, and 1 KD-5. No patients had isolated PLC injuries. Mean IKDC and Lysholm score were 73.1 ± 25.8 and 78 ± 26, respectively. Mean range of motion was -1.1 to 122.8. In full extension, two patients (10%) had grade 1 laxity to varus stress. In 30 degrees of knee flexion, five (25%) patients had grade 1 laxity, and two (10%) had grade 2 laxity. Anatomical two-tailed PLC reconstruction can reliably restore varus stability when performed on patients with MLKIs and type C posterolateral instability with hyperextension external rotation recurvatum deformity. Satisfactory functional outcome scores were achieved in the majority of patients. This study supports the use of an anatomical two-tailed PLC reconstruction in the multiligament injured knee. The level of evidence is IV, case series. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  19. Outcomes of the patellar tendon and hamstring graft anterior cruciate ligament reconstructions in patients aged above 50 years

    Directory of Open Access Journals (Sweden)

    Tarun Bali

    2015-01-01

    Full Text Available Background: The treatment of anterior cruciate ligament (ACL injury consists of arthroscopic ACL reconstruction with patellar tendon or hamstring graft. Satisfactory results have been reported so far in the younger age group. Dilemma arises regarding the suitability of ACL reconstruction in the patients aged 50 years and above. This retrospective analyses the outcome of ACL reconstruction in patients aged 50 years and above at the time of presentation. Materials and Methods: 55 patients aged 50 years and above presented to our institution with symptomatic ACL tear and were managed with arthroscopic reconstruction with patellar tendon/hamstring graft. 22 patients underwent ACL reconstruction with bone- patellar tendon-bone graft and the remaining 33 with a hamstring graft. Evaluation of functional outcome was performed using International Knee Documentation Committee (IKDC and Lysholm scoring in the preoperative period, at the end of 1 year and at the final followup. Radiographic evaluation was performed using the Kellgren–Lawrence grading system. Results: The mean preoperative IKDC score was 39.7 ± 3.3. At the end of 1-year following the operation, the mean IKDC score was 73.6 ± 4.9 and at the final followup was 67.8 ± 7.7. The mean preoperative Lysholm score was 40.4 ± 10.3. At the end of 1-year following the intervention, the mean Lysholm score was 89.7 ± 2.1 and at final followup was 85.3 ± 2.5. Overall, 14 out of 42 patients who underwent radiographic assessment showed progression of osteoarthritis changes at the final followup after the intervention. Conclusion: In our study, there was a statistically significant improvement in the IKDC and Lysholm scores following the intervention. There was a slight deterioration in the scores at the final followup but the overall rate of satisfaction was still high and most of the patients were able to do their routine chores and light exercises suitable for their age group. Around one-third of

  20. Quantification of deposition of neutrophilic granulocytes on vascular grafts in dogs with 111In-labeled granulocytes

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Solis, E.; Mackey, S.T.; Socher, S.; Chowdhury, S.; Wu, F.P.; Kaye, M.P.

    1985-01-01

    A new radioisotopic technique has been developed for quantification of deposition of neutrophilic granulocytes on vascular grafts. Nine healthy mongrel dogs underwent bilateral femoral artery resection and reconstruction with grafts of the femoral vein and Gore-Tex. Pure granulocytes that had been separated from whole blood by centrifugal elutriation were labeled with 111 In-tropolone in plasma. The granulocyte harvesting efficiency was 25 +/- 12%, and the labeling efficiency was 87 +/- 7%. Three hours after injection of labeled granulocytes and 2 hours after reperfusion, the grafts were harvested and cut into several segments for study of areas of anastomoses and midsections. On the basis of the radioactivity in the blood and in anastomotic and graft sections, the area of graft sections, and the neutrophilic granulocyte and differential leukocyte counts, the number of neutrophilic granulocytes adherent to a unit area and the total number of neutrophilic granulocytes on graft sections were calculated. These quantifications of the deposition of neutrophilic granulocytes indicated that the midsections of Gore-Tex grafts retained more neutrophilic granulocytes than did the midsections of vein grafts. Although the anastomotic areas retained more neutrophilic granulocytes than did the midsections of vein grafts, the opposite finding prevailed for the Gore-Tex grafts. A major fraction of neutrophilic granulocytes on Gore-Tex grafts was incorporated into the thrombus. Semiquantitative information obtained by scintigraphy of the deposition of neutrophilic granulocytes on vascular grafts also confirmed this observation

  1. Reconstruction of an amputated glans penis with a buccal mucosal graft: case report of a novel technique.

    Science.gov (United States)

    Aboutaleb, Hamdy

    2014-12-01

    Penile amputation is a rare catastrophe and a serious complication of circumcision. Reconstruction of the glans penis may be indicated following amputation. Our report discusses a novel technique for reconfiguration of an amputated glans penis 1 year after a complicated circumcision. A 2-year-old male infant presented to us with glans penis amputation that had occurred during circumcision 1 year previously. The parents complained of severe meatal stenosis with disfigurement of the penis. Penis length was 3 cm. Complete penile degloving was performed. The distal part of the remaining penis was prepared by removing fibrous tissue. A buccal mucosal graft was applied to the distal part of the penis associated with meatotomy. The use of a buccal mucosal graft is a successful and simple procedure with acceptable cosmetic and functional results for late reconfiguration of the glans penis after amputation when penile size is suitable.

  2. Injuries of the Portal Vein in Patients With Blunt Abdominal Trauma

    Directory of Open Access Journals (Sweden)

    D. Henne-Bruns

    1993-01-01

    four or more organs. Additionally, in 11.8% of these cases (n = 8 a major vascular injury (portal vein n = 5, vena cava n = 2, mesenteric root n = 1 was found. Injuries to the portal vein were always associated with complete rupture of the pancreas, requiring distal pancreatic resection in four cases and a duodenum preserving resection of the head of the pancreas in one. In two of these patients the portal vein had to be reconstructed with a Goretex prosthetic graft. Mortality was 14.7% for the whole group (n = 68 and 0% for patients with additional portal venous injuries.

  3. Reconstruction of anterior auricular conchal defect after malignancy excision: revolving-door flap versus full-thickness skin graft.

    Science.gov (United States)

    Dessy, Luca Andrea; Figus, Andrea; Fioramonti, Paolo; Mazzocchi, Marco; Scuderi, Nicolò

    2010-05-01

    Skin tumours of the anterior auricular concha are not uncommon. Wider excision and immediate reconstruction are required to reduce the risks of recurrence of the disease, cartilage infection and external ear distortion. Many surgical methods have been described for reconstruction of conchal defects. Post-auricular island flaps, such as the revolving-door (RD) flap, and full-thickness skin grafts (FTSGs) are the most-performed procedures. Although the RD flap has been fully described, it is not widely accepted and many surgeons, in their daily practice, prefer to use FTSG. It is a common experience that FTSGs are more subjected to centripetal contraction, decreasing the structural firmness of the conchal cavity and affecting functional and aesthetic outcomes. Furthermore, FTSGs are more prone to delay in wound healing due to the difficult access to this region that hinders adequate tie-over dressings. Between March 2003 and January 2007, 40 patients affected by T1 and T2 non-melanotic skin cancer and T1 melanoma of the anterior conchal surface of the external ear were included in a prospective study and randomly assigned to the RD reconstructed group or to the FTSG reconstructed group to investigate, compare and define advantages and disadvantages of both the techniques. Visual Analogue Scale (VAS) was used to evaluate the overall outcome and the colour and texture match. No flap or skin graft total loss was observed. Six patients (30%) showed partial failure of FTSG. The RD group demonstrated excellent cosmetic outcome, ideal colour match, adequate structure of external ear, projection and shape. Wilcoxon matched-pairs rank-sum test demonstrated statistically significant higher scores for the RD group compared to the FTSG group (p<0.0001). The RD harvesting technique is easy and quicker than the FTSG technique. RD flap should be considered as the first choice for reconstruction of anterior auricular conchal defects following wider excision of skin tumours

  4. Tibial bone fractures occurring after medioproximal tibial bone grafts for oral and maxillofacial reconstruction.

    Science.gov (United States)

    Kim, Il-Kyu; Cho, Hyun-Young; Pae, Sang-Pill; Jung, Bum-Sang; Cho, Hyun-Woo; Seo, Ji-Hoon

    2013-12-01

    Oral and maxillofacial defects often require bone grafts to restore missing tissues. Well-recognized donor sites include the anterior and posterior iliac crest, rib, and intercalvarial diploic bone. The proximal tibia has also been explored as an alternative donor site. The use of the tibia for bone graft has many benefits, such as procedural ease, adequate volume of cancellous and cortical bone, and minimal complications. Although patients rarely complain of pain, swelling, discomfort, or dysfunction, such as gait disturbance, both patients and surgeons should pay close attention to such after effects due to the possibility of tibial fracture. The purpose of this study is to analyze tibial fractures that occurring after osteotomy for a medioproximal tibial graft. An analysis was intended for patients who underwent medioproximal tibial graft between March 2004 and December 2011 in Inha University Hospital. A total of 105 subjects, 30 females and 75 males, ranged in age from 17 to 78 years. We investigated the age, weight, circumstance, and graft timing in relation to tibial fracture. Tibial fractures occurred in four of 105 patients. There were no significant differences in graft region, shape, or scale between the fractured and non-fractured patients. Patients who undergo tibial grafts must be careful of excessive external force after the operation.

  5. Acetabular reconstruction with human and bovine freeze-dried bone grafts and a reinforcement device

    Directory of Open Access Journals (Sweden)

    Ricardo Rosito

    2008-01-01

    Full Text Available BACKGROUND: This is a cohort trial (1997-2005 of 49 patients submitted to an acetabular component revision of a total hip arthroplasty, using impacted human and bovine freeze-dried cancellous bone grafts (H&FDBG and a reinforcement device. OBJECTIVE: To compare clinical/radiographic graft incorporation capability between cancellous bone grafts. PATIENTS/METHODS: There were two groups: I (n=26 receiving human grafts and II (n=25 receiving bovine grafts. The average follow-up times were 55 and 49 months, respectively. Clinical analysis was based on the Merle d'Aubigné and Postel score, and the radiographic analysis involved an established score based on Conn's et al. criteria for radiographic bone incorporation. RESULTS: No clinical/radiographic differences were found between the groups and both showed an overall rate of 88.5% and 76% of graft incorporation (p=0.424. CONCLUSION: The results presented here are comparable to those in the literature with the use of deep-FG. Therefore, cancellous bone grafts can be safely and adequately used in acetabular component revision in total hip arthroplasty.

  6. Robotic-assisted Reconstruction of the Cervix and Vagina by Small Intestinal Submucosa Graft and Fusion of the Hemiuterus.

    Science.gov (United States)

    Zhang, Ying; Chen, Yisong; Hua, Keqin

    To describe our technique of robotic-assisted reconstruction of the cervix and vagina using a small intestinal submucosa (SIS) graft and fusion of the hemiuterus. A step-by-step explanation of the procedure using video. Congenital complete vaginal and cervical atresia is rare. Some patients have urinary system abnormality. No standardized surgical treatment guideline was available, and the performance varies for each patient. We performed a robotic-assisted reconstruction of the cervix and vagina using an SIS graft (Cook Medical, Bloomington, IN) and fusion of the hemiuterus for a 12-year-old girl from China diagnosed with congenital vaginal and cervical atresia (U4C4V4). She complained of severe abdominal periodic pain for 2 months. Mammary development and her serum sex hormone were within normal range. The patient has a single kidney. The diagnosis was made according to clinical characteristics, physical examination, and magnetic resonance imaging and classified using the European Society of Human Reproduction and Embryology /European Society for Gynaecological Endoscopy (ESHRE/ESGE) system. There was a hematometra of 7-cm diameter in her pelvis. We constructed a novel vagina by sharp and blunt separation and connected it to the uterine cavity. With the SIS graft, we reconstructed her cervix and vagina, and we fused the hemiuterus to make the uterine cavity spacious. The operating time was 260 minutes, and blood loss was 300 mL. She recovered well after the operation without any complications. After surgery, the patient has had normal menstruation without pain. She insists on wearing the vaginal mold 24 hours per day. The follow-up was 10 months. The length of the vagina was 9 cm and the width was 3 cm. Robotic-assisted reconstruction of the cervix and vagina using an SIS graft and fusion of the hemiuterus is feasible and safety. However, additional studies are required. Copyright © 2016 AAGL. Published by Elsevier Inc. All rights reserved.

  7. Precision carving of costal cartilage graft for contour fill in aesthetic and reconstructive rhinoplasty

    Directory of Open Access Journals (Sweden)

    Uday Bhat

    2014-01-01

    Full Text Available Background: Autogenous costal cartilage is a good option for large volume requirements in rhinoplasty, when septal or conchal cartilages do not suffice. Reluctance to use costal cartilage is due to apprehension of warping. However, warping can be avoided if we follow the principle of balanced section as advocated by Gibson and Davis. "Warping" can also be utilized to change the curvature of the graft. Materials and Methods: We have used 69 costal cartilage grafts as a solid piece for contour fill in rhinoplasty in 31 patients over the last 10 years. Principle of balanced section as advocated by Gibson and Davis was adhered to while carving the grafts, however some grafts were allowed to warp to get different sizes and shapes. Results: All the procedures were uneventful. Aesthetic appearance of all patients was satisfactory and acceptable to all the patients. In two cases, the dorsal graft minimally shifted to one side, but remained straight. In one patient, there was late appearance of distortion. Conclusion: The mode of cartilage warping is predictable and it can be used to advantage. Apprehension to use costal cartilage graft is unjustified, as with precision carving a desired shape can be obtained.

  8. Acellular porcine small intestinal submucosa graft for cervicovaginal reconstruction in eight patients with malformation of the uterine cervix.

    Science.gov (United States)

    Ding, Jing-Xin; Chen, Xiao-Jun; Zhang, Xu-Yin; Zhang, Ying; Hua, Ke-Qin

    2014-04-01

    Can surgical reconstruction of the cervix and vagina in patients be achieved using an acellular porcine small intestinal submucosa (SIS) graft? Our experiences of combined laparoscopic and vaginal cervicovaginal reconstruction using an SIS graft in eight patients were positive, with successful reconstruction and no complications, cervical stenosis or vaginal stenosis. In patients with agenesis and dysgenesis of the uterine cervix and vagina, surgical reconstruction of the internal genitalia is a challenging problem for gynecologists. Hysterectomy with the creation of an artificial vagina was the treatment of choice in the 1990s. Recently, conservative management has been gradually adopted to avoid extirpation of the uterus, including the canalization techniques, the uterovaginal anastomosis and the reconstruction of cervical and vaginal agenesis with some autologous tissues. This prospective observational study from January 2012 to March 2013 included 8 patients aged 10-18 years with malformation of the cervix (1 with cervical agenesis, 1 with a cervical body consisting of a fibrous band and 6 with obstruction of the cervical os) and vagina (4 with complete vaginal aplasia and 4 with a 1-3 cm long vaginal pouch) diagnosed by physical examination and magnetic resonance imaging. Eight patients underwent combined laparoscopic and vaginal cervicovaginal reconstruction using an SIS graft during the end of menstruation. A T-shaped intrauterine device connected with a 14-French Foley catheter was inserted into the uterine cavity to keep the newly created cervix patent, and then a permanent lower uterine cerclage was placed. Patients were assessed post-operatively at 1, 2, 4, 6, 12 and 15 months, and data on menstruation and the morphology of the neovagina and cervix were recorded. The mean ± SD age of the patients was 14.5 ± 2.8 (10-18) years. All patients had a history of cyclic abdominal pain, and the average delay in diagnosis was 4.5 ± 4.0 (0-12) months. One

  9. MDCT angiography with 3D image reconstructions in the evaluation of failing arteriovenous fistulas and grafts in hemodialysis patients

    International Nuclear Information System (INIS)

    Dimopoulou, Angeliki; Raland, Hans; Magnusson, Anders; Wikstroem, Bjoern

    2011-01-01

    Background. Arteriovenous fistulas and grafts are the methods of choice for vascular access in renal failure patients in need of hemodialysis. Their major complication, however, is stenosis, which might lead to thrombosis. Purpose. To demonstrate the usefulness of 16-MDCTA with 3D image reconstructions, in long-term hemodialysis patients with dysfunctional arteriovenous fistulas and grafts (AVF and AVG). Material and Methods. During a 17-month period, 31 patients with dysfunctional AVF and AVG (24 AVF and seven AVG) were examined with MDCTA with 3D image postprocessing. Parameters such as comprehension of the anatomy, quality of contrast enhancement, and pathological vascular changes were measured. DSA was then performed in 24 patients. Results. MDCTA illustrated the anatomy of the AVF/AVG and the entire vascular tree to the heart, in a detailed and comprehensive manner in 93.5% of the evaluated segments, and depicted pathology of AVF/AVG or pathology of the associated vasculature. MDCTA demonstrated a total of 38 significant stenoses in 25 patients. DSA verified 37 stenoses in 24 patients and demonstrated two additional stenoses. MDCTA had thus a sensitivity of 95%. All 24 patients were treated with percutaneous transluminal angioplasty (PTA) with good technical results. Conclusion. MDCTA with 3D reconstructions of dysfunctioning AVFs and AVGs in hemodialysis patients is an accurate and reliable diagnostic method helping customize future intervention

  10. MDCT angiography with 3D image reconstructions in the evaluation of failing arteriovenous fistulas and grafts in hemodialysis patients

    Energy Technology Data Exchange (ETDEWEB)

    Dimopoulou, Angeliki; Raland, Hans; Magnusson, Anders (Dept. of Radiology, Univ. Hospital, Uppsala (Sweden)), email: angeliki.dimopoulou@akademiska.se; Wikstroem, Bjoern (Dept. of Medical Sciences, Renal Section, Univ. Hospital, Uppsala (Sweden))

    2011-11-15

    Background. Arteriovenous fistulas and grafts are the methods of choice for vascular access in renal failure patients in need of hemodialysis. Their major complication, however, is stenosis, which might lead to thrombosis. Purpose. To demonstrate the usefulness of 16-MDCTA with 3D image reconstructions, in long-term hemodialysis patients with dysfunctional arteriovenous fistulas and grafts (AVF and AVG). Material and Methods. During a 17-month period, 31 patients with dysfunctional AVF and AVG (24 AVF and seven AVG) were examined with MDCTA with 3D image postprocessing. Parameters such as comprehension of the anatomy, quality of contrast enhancement, and pathological vascular changes were measured. DSA was then performed in 24 patients. Results. MDCTA illustrated the anatomy of the AVF/AVG and the entire vascular tree to the heart, in a detailed and comprehensive manner in 93.5% of the evaluated segments, and depicted pathology of AVF/AVG or pathology of the associated vasculature. MDCTA demonstrated a total of 38 significant stenoses in 25 patients. DSA verified 37 stenoses in 24 patients and demonstrated two additional stenoses. MDCTA had thus a sensitivity of 95%. All 24 patients were treated with percutaneous transluminal angioplasty (PTA) with good technical results. Conclusion. MDCTA with 3D reconstructions of dysfunctioning AVFs and AVGs in hemodialysis patients is an accurate and reliable diagnostic method helping customize future intervention

  11. Surgical Access to Jejunal Veins for Local Thrombolysis and Stent Placement in Portal Vein Thrombosis

    International Nuclear Information System (INIS)

    Schellhammer, Frank; Esch, Jan Schulte am; Hammerschlag, Sascha; Knoefel, Wolfram Trudo; Fuerst, Guenter

    2008-01-01

    Portal vein thrombosis is an infrequent entity, which may cause high morbidity and mortality. We report a case of portal vein thrombosis due to benign stenosis following partial pancreatoduodenectomy with segmental replacement of the portal vein by a Gore-tex graft. Using a surgical access to jenunal veins, local thrombolysis, mechanical fragmentation of thrombus, and stent placement were successfully performed.

  12. Experimental Models Used in Fat Grafting Research for Volume Augmentation in Soft Tissue Reconstruction

    Directory of Open Access Journals (Sweden)

    Jorge Lujan-Hernandez

    2017-09-01

    Full Text Available As the popularity of fat grafting research increases, animal models are being used as the source of pre-clinical experimental information for discovery and to enhance techniques. To date, animal models used in this research have not been compared to provide a standardized model. We analyzed publications from 1968–2015 to compare published accounts of animal models in fat grafting research. Data collected included: species used, graft characteristics (donor tissue, recipient area, amount injected, injection technique, time of sacrifice and quantification methods. Mice were most commonly used (56% of studies, with the “athymic nude” strain utilized most frequently (44%. Autologous fat was the most common source of grafted tissue (52%. Subcutaneous dorsum was the most common recipient site (51%. On average, 0.80±0.60 mL of fat was grafted. A single bolus technique was used in 57% of studies. Fat volume assessment was typically completed at the end of the study, occurring at less than 1 week to one year. Graft volume was quantified by weight (63%, usually in conjunction with another analysis. The results demonstrate the current heterogeneity of animal models in this research. We propose that the research community reach a consensus to allow better comparison of techniques and results. One example is the model used in our laboratory and others; this model is described in detail. Eventually, larger animal models may better translate to the human condition but, given increased financial costs and animal facility capability, should be explored when data obtained from small animal studies is exhausted or inconclusive.

  13. Antiplatelet drug selection in PCI to vein grafts in patients with acute coronary syndrome and adverse clinical outcomes: Insights from the British Cardiovascular Intervention Society database.

    Science.gov (United States)

    Sirker, Alex; Kwok, Chun Shing; Kontopantelis, Evangelos; Johnson, Tom; Freeman, Philip; de Belder, Mark A; Ludman, Peter; Zaman, Azfar; Mamas, Mamas A

    2018-01-22

    This study aims to evaluate outcomes associated with different P2Y12 agents in Saphenous Vein graft (SVG) percutaneous coronary intervention (PCI). SVG PCI is associated with greater risks of ischemic complications, compared with native coronary PCI. Outcomes associated with the use of potent P2Y12 blocking drugs, Prasugrel and Ticagrelor, in SVG PCI are unknown. Patients included in the study underwent SVG PCI in the United Kingdom between 2007 and 2014 for acute coronary syndrome and were grouped by P2Y12 antiplatelet use. In-hospital major adverse cardiac events, major bleeding and 30-day and 1-year mortality were examined. Multiple imputations with chained equations to impute missing data were used. Adjustment for baseline imbalances was performed using (1) multiple logistic regression (MLR) and (separately) (2) propensity score matching (PSM). Data weres analyzed from 8,119 patients and most cases were treated with Clopidogrel (n = 7,401), followed by Ticagrelor (n = 497) and Prasugrel (n = 221). In both MLR and PSM models, there was no significant evidence to suggest that either Prasugrel or Ticagrelor was associated with significantly lower 30-day mortality compared with Clopidogrel. The odds ratios reported from the multivariable analysis were 1.22 (95% CI: 0.60-2.51) for Prasugrel vs. Clopidogrel and 0.48 (95% CI: 0.20-1.16) for Ticagrelor vs. Clopidogrel. No significant differences were seen for in-hospital ischemic or bleeding events. Our real world national study provides no clear evidence to indicate that use of potent P2Y12 blockers in SVG PCI is associated with improved clinical outcomes. © 2018 Wiley Periodicals, Inc.

  14. FUNCTIONAL OUTCOME OF ACCELERATED REHABILITATION IN ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION WITH BONE PATELLAR TENDON BONE GRAFT A PROSPECTIVE STUDY

    Directory of Open Access Journals (Sweden)

    Hiranyakumar

    2016-03-01

    Full Text Available INTRODUCTION An ideal rehabilitation program post anterior cruciate ligament reconstruction enables an individual to return to pre injury levels at a faster rate with minimal to no risk of reinjury to the graft. Rehabilitation protocols have changed considerably over time in the past. It has become “aggressive”, meaning an intensive rehabilitation which includes greater variety of exercises and sports related training. AIM OF THE STUDY The aim of our study is to assess the outcome of accelerated rehabilitation post anterior cruciate ligament (ACL reconstruction. METHODOLOGY 106 patients were operated by a single surgeon underwent arthroscopic anterior cruciate ligament reconstruction using bone patella tendon bone graft and partial meniscectomy for associated meniscal tear. Patients were put on an accelerated rehabilitation protocol designed in our institute on first post-operative day, under the guidance of a physical therapist in consultation with the operated surgeon. Patients were followed up at 3 weeks, 6 months and 9 months, post onset of rehabilitation, patients were assessed using KT1000 Arthrometer and Lysholm knee scoring system. RESULTS Out of 106 patients, who were selected, 96(91% were males and 10(9% were females. The mean pre-operative Lysholm score was 55.09. Post operatively, while on accelerated rehabilitation program the Lysholm scores were 69.73 at 3 weeks, 89.13 at 6 months and 89.19 at 9 months. In our pre-operative evaluation mean KT 1000 arthrometer score was 10.53 and post-operative at six months was 3.49. At nine months 105 patients had excellent results whereas 1 patient had good result. CONCLUSION Accelerated rehabilitation protocol enables the patient to functionally recover faster to pre injury levels. A rehabilitation protocol for 6 months is sufficient in enabling a patient to get back to pre-injury levels. Functional outcome is the same with or without associated meniscal injuries.

  15. Free muscle transfer with split thickness skin graft coverage in head and neck reconstructive surgery

    NARCIS (Netherlands)

    Bos, K. E.; Balm, A. J.; Schouwenburg, P. F.; Hilgers, F. J.; de Boer, J. B.

    1991-01-01

    Sixteen patients (eight females and eight males) who underwent microsurgical free tissue transfers for head and neck reconstruction are reviewed. In this series, the flap reconstruction was completed on eleven patients with extra-oral defects and five with intra-oral defects. Split thickness skin

  16. Noninvasive detection of coronary artery bypass graft patency by intravenous electron beam computed tomographic angiography.

    Science.gov (United States)

    Yamakami, Shoji; Toyama, Junji; Okamoto, Mitsuhiro; Matsushita, Toyoaki; Murakami, Yoshimasa; Ogata, Masaki; Ito, Shigenori; Fukutomi, Tatsuya; Okayama, Naotsuka; Itoh, Makoto

    2003-11-01

    This study evaluates the usefullness of intravenous electron beam computed tomographic angiography (EBA) for the detection of coronary artery bypass graft patency in 43 patients (33 men and 10 women, mean age, 65 years) who had coronary artery bypass graft surgery. EBA was performed a few days before selective bypass graft angiography (SGA). Forty axial cross-sections of angiographic images of the heart were acquired consecutively by an electrocardiographic trigger signal at 40% of the RR interval, which corresponds to the end-systolic phase. EBA data were reconstructed as a three-dimensional shaded surface display of the heart and bypass grafts. Detectability of the patency of bypass gratis was evaluated, taking selective angiographic images of the bypass grafts as a gold standard. One hundred and nine grafts (96%) out of 114 grafts were subjected to evaluation: 37 grafts were left internal mammary artery grafts (LIMA), 7 were right internal mammary artery grafts (RIMA), 6 were gastroepiploic artery grafts (GEA), 7 were free gastroepiploic artery grafts with venous drainage (free-GEA), 7 were radial artery grafts (RAG), and 45 were saphenous vein gratis (SVG). The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of EBA were 98%, 100%, 100%, 91%, and 98%, respectively. EBA sampled at the end-systolic period was determined to be useful for the detection of coronary artery bypass graft patency and occlusion.

  17. Supplementation of fat grafts with adipose-derived regenerative cells in reconstructive surgery [Stammzellangereicherte Fetttransplantation in der rekonstruktiven Chirurgie

    Directory of Open Access Journals (Sweden)

    Herold, C.

    2012-09-01

    Full Text Available [english] Introduction: The fraction of regenerative cells in adipose tissue has been described to be even higher than in bone marrow. Adipose tissue itself is excessively available in most patients. Given that adipose tissue is abundant in majority of patients adipose derrived stem cells (ASCs have come under scrutiny for regenerative procedures in reconstructive surgery.Material and methods: ASCs were extracted by the Celution system for enrichment of fat grafts that were administered in patients with decreased wound healing, soft tissue or scar defects.Results: All patients were satisfied after reconstruction with ASCs augmented fat grafts and no side effects were observed. Discussion: The Celution system provides fast recovery of ASCs which can be immediately utilized for appropriate application. Since a high number of stem cells are harvested from fat tissue no expansion of cells is needed as described for bone marrow derived stem cells. Enrichment of fat graft with ASCs is of great interest due to their reported angiogenetic effect. The reported cases demonstrate the potential of ASCs in the field of regenerative medicine and encourage further application in reconstructive surgery.[german] Einleitung: Es konnte gezeigt werden, dass der Anteil regenerativer Zellen im Fettgewebe höher als im Knochenmark ist. Fettgewebe hingegen ist bei den meisten Patienten exzessiv vorhanden. Das legt den Einsatz von ASCs (adipose derived stem cells bei regenerativen Anwendungen in der rekonstruktiven Chirurgie nahe.Material und Methoden: Mit dem Celution System von Cytori Therapeutics Inc. prozessierte, ASC angereicherte Fetttransplantate werden an vier Patienten mit Weichteildefiziten und störenden Narben sowie Wundheilungsstörungen angewendet.Ergebnisse: Insbesondere bei Patienten mit Weichteildefiziten und Narben konnte eine suffiziente Volumenaugmentation und ansprechende Verbesserung der Narben erzielt werden. Es wurden keine Nebenwirkungen

  18. Editorial Commentary: Graft Removal Versus Retention for Septic Arthritis After Anterior Cruciate Ligament Reconstruction: Accounting for Patient Preference Flips the Script on Current Practice.

    Science.gov (United States)

    Cote, Mark P

    2018-03-01

    Septic arthritis is a rare but potentially devastating complication after anterior cruciate ligament (ACL) reconstruction. Studies examining surgical treatment options including graft retention and removal are largely inconclusive. Although the literature indicated that 43.8% of patients who have the graft removed later go on to have a revision ACL reconstruction compared with only 6.5% among those whose graft is retained, this expected-value decision analysis found removal to be the optimal treatment for patients with septic arthritis after ACL reconstruction. This is largely based on patient preference to avoid a late reoperation for residual knee infection. These findings support the concept of utility when considering treatment options for patients with a septic knee. For some, avoiding a late reoperation for a persistent infection is the most important factor and as such graft removal may be the most appropriate treatment to produce a positive outcome among these patients despite the fact that currently, an attempt at graft retention could represent the generally preferred treatment option among practicing surgeons. Copyright © 2017. Published by Elsevier Inc.

  19. Histomorhological and clinical evaluation of maxillary alveolar ridge reconstruction after craniofacial trauma by applying combination of allogeneic and autogenous bone graft

    Directory of Open Access Journals (Sweden)

    Francesco Saverio De Ponte

    2017-02-01

    Full Text Available A variety of techniques and materials for the rehabilitation and reconstruction of traumatized maxillary ridges prior to dental implants placement have been described in literature. Autogenous bone grafting is considered ideal by many researchers and it still remains the most predictable and documented method. The aim of this report is to underline the effectiveness of using allogeneic bone graft for managing maxillofacial trauma. A case of a 30-year-old male with severely atrophic maxillary ridge as a consequence of complex craniofacial injury is presented here. Augmentation procedure in two stages was performed using allogeneic and autogenous bone grafts in different areas of the osseous defect. Four months after grafting, during the implants placement surgery, samples of both sectors were withdrawn and submitted to histological evaluation. On the examination of the specimens, treated by hematoxylin and eosin staining, the morphology of integrated allogeneic bone grafts was revealed to be similar to the autologous bone. Our clinical experience shows how the allogeneic bone graft presented normal bone tissue architecture and is highly vascularized, and it can be used for reconstruction of severe trauma of the maxilla.

  20. Histomorhological and clinical evaluation of maxillary alveolar ridge reconstruction after craniofacial trauma by applying combination of allogeneic and autogenous bone graft.

    Science.gov (United States)

    De Ponte, Francesco Saverio; Falzea, Roberto; Runci, Michele; Siniscalchi, Enrico Nastro; Lauritano, Floriana; Bramanti, Ennio; Cervino, Gabriele; Cicciu, Marco

    2017-02-01

    A variety of techniques and materials for the rehabilitation and reconstruction of traumatized maxillary ridges prior to dental implants placement have been described in literature. Autogenous bone grafting is considered ideal by many researchers and it still remains the most predictable and documented method. The aim of this report is to underline the effectiveness of using allogeneic bone graft for managing maxillofacial trauma. A case of a 30-year-old male with severely atrophic maxillary ridge as a consequence of complex craniofacial injury is presented here. Augmentation procedure in two stages was performed using allogeneic and autogenous bone grafts in different areas of the osseous defect. Four months after grafting, during the implants placement surgery, samples of both sectors were withdrawn and submitted to histological evaluation. On the examination of the specimens, treated by hematoxylin and eosin staining, the morphology of integrated allogeneic bone grafts was revealed to be similar to the autologous bone. Our clinical experience shows how the allogeneic bone graft presented normal bone tissue architecture and is highly vascularized, and it can be used for reconstruction of severe trauma of the maxilla. Copyright © 2017 Daping Hospital and the Research Institute of Surgery of the Third Military Medical University. Production and hosting by Elsevier B.V. All rights reserved.

  1. The vein collar

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  2. Myocutaneous pedicle flap combined with a free skin graft for upper eyelid reconstruction

    DEFF Research Database (Denmark)

    Toft, Peter B

    2010-01-01

    Repair of large upper eyelid defects can be accomplished by both 1-stage and 2-stage techniques some of which are complicated and time consuming. I here present a simple 1-stage technique for upper eyelid reconstruction....

  3. Oncological Recurrence after Autologous Fat Grafting in Breast Reconstruction : Critical appraisal of the current literature on basic science and clinical studies

    NARCIS (Netherlands)

    Groen, Jan-Willem; Tuinder, Stephania M.H.; Negenborn, Vera L.; van der Hulst, Rene

    Background The use of Autologous Fat Grafting (AFG) in surgical procedures of the female breast has gained enormous international interest over the last decade with indications ranging from aesthetic augmentation to the treatment of postmastectomy-pain-syndromes and breast-reconstructions. One of

  4. The pedicled omentoplasty and split skin graft (POSSG) for reconstruction of large chest wall defects. A validity study of 34 patients

    NARCIS (Netherlands)

    C.M.E. Contant; A.N. van Geel (Albert); B. van der Holt (Bronno); T. Wiggers (Theo)

    1996-01-01

    textabstractThe aim of this study was to evaluate retrospectively the results of pedicled omentoplasty and split skin graft (POSSG) in reconstructing (full thickness) chest wall defects, and to define its role as a palliative procedure for local symptom control. Thirty-four patients with recurrent

  5. Fixation methods in mandibular reconstruction using fibula grafts: a comparative study into the relative strength of three different types of osteosynthesis

    NARCIS (Netherlands)

    Strackee, S. D.; Kroon, F. H.; Bos, K. E.

    2001-01-01

    Bone staples made of a nickel titanium alloy exert dynamic compression, require little dissection, and may provide an alternative to conventional fixation in mandibular reconstruction with a free vascularized fibula graft. To evaluate its stability relative to conventional methods of fixation with

  6. Loss of reduction and complications of coracoclavicular ligament reconstruction with autogenous tendon graft in acute acromioclavicular dislocations.

    Science.gov (United States)

    Choi, Nam Hong; Lim, Seok Min; Lee, Sang Young; Lim, Tae Kang

    2017-04-01

    This study was conducted to report loss of reduction and complications after single-tunnel coracoclavicular (CC) ligament reconstruction with autogenous semitendinosus tendon graft for acute acromioclavicular (AC) joint dislocations. This retrospective study included patients with acute, unstable AC dislocations (surgery within 6 weeks after trauma). We excluded patients with chronic injury and distal clavicle fractures with CC ligaments disruption. We measured the CC distance on anteroposterior radiographs of both clavicles, preoperatively, immediately postoperatively, and at the final follow-up visit. We evaluated clinical outcomes using the American Shoulder and Elbow Surgeons Shoulder Assessment and the University of California, Los Angeles Shoulder Rating Scale scores and perioperative complications. There were 30 patients (27 men and 3 women) with mean age of 41 years (range, 19-70 years). The mean follow-up period was 31 months (range, 12-186 months). Mean CC distance was 15.5 ± 3.7 mm (84% ± 14% of the contralateral shoulder) preoperatively, 8.9 ± 2.6 mm (9% ± 40%) immediately postoperatively (P 25% increase of CC distance) developed in 14 patients (47%), and complications occurred in 6 patients (20%), including 3 distal clavicle fractures through the tunnel. Final clinical scores were significantly lower in patients with complications (27 vs. 33 of the University of California, Los Angeles assessment [P < .001] and 81 vs. 95 of the American Shoulder and Elbow Surgeons Shoulder assessment [P < .001]). In acute AC joint dislocation, single-tunnel CC ligament reconstruction using autogenous tendon graft resulted in loss of reduction rate of 47% and a complication rate of 20%. The development of complications adversely affected clinical outcomes. Copyright © 2017 Journal of Shoulder and Elbow Surgery Board of Trustees. Published by Elsevier Inc. All rights reserved.

  7. Drug-eluting stents appear superior to bare metal stents for vein-graft PCI in vessels up to a stent diameter of 4 mm

    Directory of Open Access Journals (Sweden)

    Oliver P. Guttmann

    2016-05-01

    Full Text Available BackgroundResearch trials have shown improved short-term outcome with drug-eluting stents (DES over bare metal stents (BMS in saphenous vein graft (SVG percutaneous coronary intervention (PCI, primarily by reducing target vessel revascularization (TVR for in-stent restenosis. We compared the outcomes in patients undergoing SVG stent implantation treated with DES or BMS. In exploratory analyses we investigated the influence of stent generation and diameter.MethodsData were obtained from a prospective database of 657 patients who underwent PCI for SVG lesions between 2003 and 2011. A total of 344 patients had PCI with BMS and 313 with DES. Propensity scores were developed based on 15 observed baseline covariates in a logistic regression model with stent type as the dependent variable. The nearest-neighbour-matching algorithm with Greedy 5-1 Digit Matching was used to produce two patient cohorts of 313 patients each. We assessed major adverse cardiac events (MACE out to a median of 3.3 years (interquartile range: 2.1-4.1. MACE was defined as all-cause mortality, myocardial infarction (MI, TVR and stroke.ResultsThere was a significant difference in MACE between the two groups in favour of DES (17.9% DES vs. 31.2% BMS group; p = 0.0017 over the 5-year follow-up period. MACE was driven by increased TVR in the BMS group. There was no difference in death, MI or stroke. Adjusted Cox analysis confirmed a decreased risk of MACE for DES compared with BMS 0.75 (95% confidence interval (CI 0.52-0.94, with no difference in the hazard of all-cause mortality (hazard ratio: 1.08; 95% CI: 0.77-1.68. However, when looking at stent diameters greater than 4 mm, no difference was seen in MACE rates between BMS and DES.ConclusionsOverall in our cohort of patients who had PCI for SVG disease, DES use resulted in lower MACE rates compared with BMS over a 5-year follow-up period; however, for stent diameters over 4 mm no difference in MACE rates was seen.

  8. Saphenous vein graft near-infrared spectroscopy imaging insights from the lipid core plaque association with clinical events near-infrared spectroscopy (ORACLE-NIRS) registry.

    Science.gov (United States)

    Danek, Barbara A; Karatasakis, Aris; Alame, Aya J; Nguyen-Trong, Phuong-Khanh J; Karacsonyi, Judit; Rangan, Bavana; Roesle, Michele; Atwell, Amy; Resendes, Erica; Martinez-Parachini, Jose Roberto; Iwnetu, Rahel; Kalsaria, Pratik; Siddiqui, Furqan; Muller, James E; Banerjee, Subhash; Brilakis, Emmanouil

    2017-05-01

    We sought to examine near-infrared spectroscopy (NIRS) imaging findings of aortocoronary saphenous vein grafts (SVGs). SVGs are prone to develop atherosclerosis similar to native coronary arteries. They have received little study using NIRS. We examined the clinical characteristics and imaging findings from 43 patients who underwent NIRS imaging of 45 SVGs at our institution between 2009 and 2016. The mean patient age was 67 ± 7 years and 98% were men, with high prevalence of diabetes mellitus (56%), hypertension (95%), and dyslipidemia (95%). Mean SVG age was 7 ± 7 years, mean SVG lipid core burden index (LCBI) was 53 ± 60 and mean maxLCBI 4 mm was 194 ± 234. Twelve SVGs (27%) had lipid core plaques (2 yellow blocks on the block chemogram), with a higher prevalence in SVGs older than 5 years (46% vs. 5%, P = 0.002). Older SVG age was associated with higher LCBI (r = 0.480, P < 0.001) and higher maxLCBI 4 mm (r = 0.567, P < 0.001). On univariate analysis, greater annual total cholesterol exposure was associated with higher SVG LCBI (r = 0.30, P = 0.042) and annual LDL-cholesterol and triglyceride exposure were associated with higher SVG maxLCBI 4 mm (LDL-C: r = 0.41, P = 0.020; triglycerides: r = 0.36, P = 0.043). On multivariate analysis, the only independent predictor of SVG LCBI and maxLCBI 4mm was SVG age. SVG percutaneous coronary intervention was performed in 63% of the patients. An embolic protection device was used in 96% of SVG PCIs. Periprocedural myocardial infarction occurred in one patient. Older SVG age and greater lipid exposure are associated with higher SVG lipid burden. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  9. Medial Patellofemoral Ligament Reconstruction: Impact of Knee Flexion Angle During Graft Fixation on Dynamic Patellofemoral Contact Pressure-A Biomechanical Study.

    Science.gov (United States)

    Lorbach, Olaf; Zumbansen, Nikolaus; Kieb, Matthias; Efe, Turgay; Pizanis, Antonius; Kohn, Dieter; Haupert, Alexander

    2018-04-01

    Objective evaluation of the optimal graft tension angle to fully restore patellofemoral contact pressure in reconstruction of the medial patellofemoral ligament (MPFL) in comparison to the native knee. Twelve cadaveric knee specimens were fixed in a custom-made fixation device. A sensitive pressure film (Tekscan) was fixed in the patellofemoral joint, and patellofemoral contact pressure was assessed during a dynamic flexion movement from 0° to 90°. The MPFL was cut and measurements were repeated. Reconstruction of the MPFL was performed with the gracilis tendon subsequently fixed in the femur at 15°, 30°, 45°, 60°, 75°, and 90° of knee flexion under controlled tension (2 N). The sequence of the flexion angles was alternated. Pressure measurements were repeated after every fixation of the graft. No significant differences were seen in the overall patellofemoral contact pressure compared to the native knee (P > .05). However, medial patellofemoral pressure showed a significant increased patellofemoral contact pressure after MPFL reconstruction at a knee flexion angle during graft fixation of 15° (P = .027), 45° (P = .050, P = .044), and 75° (P = .039). Moreover, proximal/distal patellofemoral contact pressure revealed a significantly reduced contact pressure at 15° (P = .003), 30° (P = .009), 45° (P = .025), 75° (P = .021), and 90° (P = .022) of flexion distal after MPFL reconstruction compared with the intact knee. Lateral patellofemoral contact pressure was significantly reduced in all performed reconstructions (P angle during graft fixation for MPFL reconstruction did not have a significant impact on the overall patellofemoral contact pressure. However, selective medial, proximal, distal, and lateral patellofemoral contact pressure was significantly altered for all reconstructions. Fixation of the MPFL graft at 60° of flexion was able to most closely restore patellofemoral contact pressure compared with the intact knee. Based on the

  10. Total Reconstruction of the Upper Lip Using Bilateral Nasolabial Flaps, Submental Flap, and Mucosa Graft following Complete Resection for Squamous Cell Carcinoma

    Directory of Open Access Journals (Sweden)

    O. G. Oseni

    2015-01-01

    Full Text Available Lip reconstruction following resection for tumour or following extensive trauma may pose a challenge. This is more so when the resection is total and a complete lip has to be constructed. We present a case of lip reconstruction following a total resection of the upper lip. The procedure used in this case was a combination of bilateral nasolabial flaps with a submental flap and buccal mucosal graft lining. We believe that this provides an alternative method of total upper lip reconstruction with minimal disruption of the facial aesthesis.

  11. Ilizarov bone transport versus fibular graft for reconstruction of tibial bone defects in children.

    Science.gov (United States)

    Abdelkhalek, Mostafa; El-Alfy, Barakat; Ali, Ayman M

    2016-11-01

    The aim of this study was to compare the results of treatment of segmental tibial defects in the pediatric age group using an Ilizarov external fixator versus a nonvascularized fibular bone graft. This study included 24 patients (age range from 5.5 to 15 years) with tibial bone defects: 13 patients were treated with bone transport (BT) and 11 patients were treated with a nonvascularized fibular graft (FG). The outcome parameters were bone results (union, deformity, infection, leg-length discrepancy) and functional results: external fixation index and external fixation time. In group A (BT), one patient developed refracture at the regenerate site, whereas, in group B (FG), after removal of the external fixator, one of the FGs developed a stress fracture. The external fixator time in group A was 10.7 months (range 8-14.5) versus 7.8 months (range 4-11.5 months) in group B (FG). In group A (BT), one patient had a limb-length discrepancy (LLD), whereas, in group B (FG), three patients had LLD. The functional and bone results of the Ilizarov BT technique were excellent in 23.1 and 30.8%, good in 38.5 and 46.2, fair in 30.8 and 15.4, and poor in 7.6 and 7.6%, respectively. The poor functional result was related to the poor bone result because of prolonged external fixator time resulting in significant pain, limited ankle motion, whereas the functional and bone results of fibular grafting were excellent in 9.1 and 18.2%, good in 63.6 and 45.5%, fair in 18.2 and 27.2%, and poor in 9.1 and 9.1%, respectively. Segmental tibial defects can be effectively treated with both methods. The FG method provides satisfactory results, with early removal of the external fixator. However, it had a limitation in patients with severe infection and those with LLD. Also, it requires a long duration of limb bracing until adequate hypertrophy of the graft. The Ilizarov method has the advantages of early weight bearing, treatment of postinfection bone defect in a one-stage surgery, and the

  12. A Comparison of the Local Flap and Skin Graft by Location of Face in Reconstruction after Resection of Facial Skin Cancer.

    Science.gov (United States)

    Lee, Kyung Suk; Kim, Jun Oh; Kim, Nam Gyun; Lee, Yoon Jung; Park, Young Ji; Kim, Jun Sik

    2017-12-01

    Surgery for reconstruction of defects after surgery should be performed selectively and the many points must be considered. The authors conducted this study to compare the local flap and skin graft by facial location in the reconstruction after resection of facial skin cancer. The authors performed the study in patients that had received treatment in Department of Plastic Surgery, Gyeongsang National University. The cases were analyzed according to the reconstruction methods for the defects after surgery, sex, age, tumor site, and tumor size. Additionally, the authors compared differences of aesthetic satisfaction (out of 5 points) of patients in the local flap and skin graft by facial location after resection of facial skin cancer by dividing the face into eight areas. A total of 153 cases were confirmed. The most common facial skin cancer was basal cell carcinoma (56.8%, 87 cases), followed by squamous cell carcinoma (37.2%, 57 cases) and bowen's disease (5.8%, 9 cases). The most common reconstruction method was local flap 119 cases (77.7%), followed by skin graft 34 cases (22.3%). 86 patients answered the questionnaire and mean satisfaction of the local flap and skin graft were 4.3 and 3.5 ( p =0.04), respectively, indicating that satisfaction of local flap was significantly high. When comparing satisfaction of patients according to results, local flap shows excellent effects in functional and cosmetic aspects would be able to provide excellent results rather than using a skin graft with poor touch and tone compared to the surrounding normal skin.

  13. Ipsilateral free semitendinosus tendon graft transfer for reconstruction of chronic tears of the Achilles tendon

    Directory of Open Access Journals (Sweden)

    Gougoulias Nikolaos

    2008-07-01

    Full Text Available Abstract Background Many techniques have been developed for the reconstruction of the Achilles tendon in chronic tears. In presence of a large gap (greater than 6 centimetres, tendon augmentation is required. Methods We present our method of minimally invasive semitendinosus reconstruction for the Achilles tendon using one para-midline and one midline incision. Results The first incision is a 5 cm longitudinal incision, made 2 cm proximal and just medial to the palpable end of the residual tendon. The second incision is 3 cm long and is also longitudinal but is 2 cm distal and in the midline to the distal end of the tendon rupture. The distal and proximal Achilles tendon stumps are mobilised. After trying to reduce the gap of the ruptured Achilles tendon, if the gap produced is greater than 6 cm despite maximal plantar flexion of the ankle and traction on the Achilles tendon stumps, the ipsilateral semitendinosus tendon is harvested. The semitendinosus tendon is passed through small incisions in the substance of the proximal stump of the Achilles tendon, and it is sutured to the Achilles tendon. It is then passed beneath the intact skin bridge into the distal incision, and passed from medial to lateral through a transverse tenotomy in the distal stump. With the ankle in maximal plantar flexion, the semitendinosus tendon is sutured to the Achilles tendon at each entry and exit point Conclusion This minimally invasive technique allows reconstruction of the Achilles tendon using the tendon of semitendinosus preserving skin integrity over the site most prone to wound breakdown, and can be especially used to reconstruct the Achilles tendon in the presence of large gap (greater than 6 centimetres.

  14. A study on evaluation of portal vein by utilizing MIP reconstruction in the PC environment after abdomen CT of hepatic artery embolization patients

    International Nuclear Information System (INIS)

    Kim, Young Keun; Jang, Young Ill; Heo, Young Nam

    2001-01-01

    When most patients are diagnosed with the quiet progressed hepatoma which often would make the operation impossible, the Interventional Radiology hepatic artery embolization is an extremely useful method for such patients. An existence of the malfunction is evaluated by gaining a portal vein image as a delayed phase image after injecting a contrast media into the superior mesenteric artery. However, it is difficult to make a definite judgement due to the extended exposure time with the peristalsis and the intestine gas obstructing the sharpness of the image when the patient exposure time increases and due to the increased usage of contrast media and its side effect. The portal vein can be evaluated by obtaining the MIP image after reconstructing a 3-dimensional personal computer setting using the 2-dimensional from an enhancement abdomen CT image that is almost a requisite in operation to a hepatoma patient. Such method may prevent a decrease in the quality of image based upon the time delay and intestine gas; also, because the patient exposure dose and contrast media usage may be reduced, it is a new, valuable way to decide the operational matter of hepatic artery embolization on a pre-angiography

  15. Planning of vessel grafts for reconstructive surgery in congenital heart diseases

    Science.gov (United States)

    Rietdorf, U.; Riesenkampff, E.; Schwarz, T.; Kuehne, T.; Meinzer, H.-P.; Wolf, I.

    2010-02-01

    The Fontan operation is a surgical treatment for patients with severe congenital heart diseases, where a biventricular correction of the heart can't be achieved. In these cases, a uni-ventricular system is established. During the last step of surgery a tunnel segment is placed to connect the inferior caval vein directly with the pulmonary artery, bypassing the right atrium and ventricle. Thus, the existing ventricle works for the body circulation, while the venous blood is passively directed to the pulmonary arteries. Fontan tunnels can be placed intra- and extracardially. The location, length and shape of the tunnel must be planned accurately. Furthermore, if the tunnel is placed extracardially, it must be positioned between other anatomical structures without constraining them. We developed a software system to support planning of the tunnel location, shape, and size, making pre-operative preparation of the tunnel material possible. The system allows for interactive placement and adjustment of the tunnel, affords a three-dimensional visualization of the virtual Fontan tunnel inside the thorax, and provides a quantification of the length, circumferences and diameters of the tunnel segments. The visualization and quantification can be used to plan and prepare the tunnel material for surgery in order to reduce the intra-operative time and to improve the fit of the tunnel patch.

  16. Dorsal capsulodesis associated with arthoscopy-assisted scapholunate ligament reconstruction using a palmaris longus tendon graft

    Directory of Open Access Journals (Sweden)

    Victor Bignatto Carvalho

    Full Text Available ABSTRACT OBJECTIVES: To measure the quality of life, the time to work return, and clinical, functional, and radiographic parameters of patients treated with dorsal capsulodesis associated with scapholunate (SL reconstruction, assisted by arthroscopy. METHODS: From January 2015 to September 2016, 14 adult patients with SL dissociation underwent surgical treatment with the SL reconstruction procedure assisted by arthroscopy, using the new technique proposed in this study. All patients were assessed by the occupational therapy department at regular intervals after surgery and performed the same sequence of rehabilitation. The parameters analyzed were: range of motion (ROM, Disability of the Arm, Shoulder, and Hand (DASH, visual analog scale (VAS, and radiographic analysis to visualize the pre- and postoperative SL gap and the pre- and postoperative dorsal intercalated segment instability (DISI deformity the. The complications and the time to return to work activities were described. RESULTS: The follow-up time was 12 months (3-17. The ROM averaged 321° (96.9% of the normal side. VAS was 1.79/10 (1-6. DASH was 6.50/100 (1-30. The time to work return work was 4.42 months (2-17. As for complications, one patient developed SLAC, and underwent four-corner fusion one year after ligament reconstruction. Currently, he has experienced pain relief, with a functional range of motion of the wrist, and has not yet returned to professional activities. The preoperative SL gap was 4.29 mm (2-7; in the postoperative period, it was 1.79 mm (1-4. The DISI deformity was present in ten patients with SL angle > 70° (preoperative and it was corrected after surgery, in all patients. SLAC stage I was identified in a patient. Arthroscopy was performed in all cases. The SL instability was classified as Geissler grade III in four cases and as grade IV in ten cases. CONCLUSION: The new approach (dorsal capsulodesis associated with SL reconstruction, assisted by arthroscopy

  17. Use of Fat Grafts in Facial Reconstruction on the Wounded Soldiers From the First World War (WWI) by Hippolyte Morestin (1869-1919).

    Science.gov (United States)

    Benmoussa, Nadia; Hansen, Kevin; Charlier, Philippe

    2017-11-01

    During the Great War of 1914 to 1918, spectacular progress was made in the field of facial reconstruction. The sheer number and severity of facial lesions inflicted during the fighting obliged French and German surgeons to take a close interest in the treatment of patients wounded in such a manner. As head surgeon of the fifth division "blessés de la face" at the hospital of Val-de-Grace, Hippolyte Morestin was responsible for one of the largest surgical departments specializing in facial surgery and reconstruction during the war. During his time of service, he developed various surgical techniques such as autoplasties using cartilaginous and adipose grafts to reconstruct tissue defects. This study focuses primarily on the adipose graft techniques and their aesthetic outcome used by Morestin during and in the aftermath of World War I. This is a historical descriptive study. Our research is based on documents available at the museum and archives of the Val-de-Grace Army Health Service (hospital activity reports, pre- and postoperative patient photographs, newspaper clippings, documented accounts of ward nurses, wax anatomy models). Thirty-four clinical cases published by Hippolyte Morestin dealing with facial reconstruction during the World War I were studied. Fat was mainly used to fill craniofacial substance losses after carrying out often complex reconstructions. The surgical technique is well documented and subdivided into 3 succeeding procedures. Most of the time, the grafts were of autologous origin but sometimes heterologous samples were used. Although the primary objective was to increase volume, an improved quality of skin healing and better skin flexibility were observed. The fat thus allowed the filling of substance losses, and its positive effects on scarring were noticed even before the regenerative properties of the stem cells present in body fat were discovered. Hippolyte Morestin can be named one of the pioneers of facial reconstruction. A

  18. Brachial artery repair using the basilic vein as a reliable conduit in a 3-year-old child

    Directory of Open Access Journals (Sweden)

    Hyunyoung G. Kim

    2017-04-01

    Full Text Available A supracondylar fracture of the humerus is the most common upper extremity fracture in children with concurrent neurovascular complications. However, bypass grafting in the management of a pediatric open elbow dislocation with an arterial injury has rarely been reported in the literature. Hence, an adequate conduit for a vessel graft interposition remains questionable when a primary anastomosis is limited in an arterial reconstruction. The purpose of this study is to present a brachial artery reconstruction in a 3-year-old patient with an open supracondylar fracture of the humerus. In the clinical and surgical examination of the patient, an open wound in the left antecubital fossa presented with accompanying brachial artery injury. To repair the artery, a reverse end-to-end anastomosis was conducted using basilic vein graft from the ipsilateral arm under general anesthesia. The patient had palpable radial pulses in the postoperative clinical examination and was discharged without complications. The great saphenous vein (GSV has proven to be the most common and the best conduit for arterial reconstruction of the upper extremity in the adult patients. However, the GSV graft is known to have the propensity for becoming aneurysmal in pediatric patients. Some studies have demonstrated the basilic vein as a suitable conduit in pediatric patients, in that it has durable patency, fewer branches, size compatibility for anastomosis, and proximity to the brachial artery. Our case confirms the safety of using this autogenous vein from within the zone of injury for arterial reconstruction, after a supracondylar humeral fracture. The management of pediatric elbow fractures accompanying vascular injuries can be technically demanding due to relatively small, delicate structures and concurrent neurovascular network. Nonetheless, a vascular injury should be treated with high level of suspicion and immediate intervention to avoid any limb ischemia or loss. In

  19. Reconstruction of juxta-articular huge defects of distal femur with vascularized fibular bone graft and Ilizarov's distraction osteogenesis.

    Science.gov (United States)

    Lai, Davy; Chen, Chuan-Mu; Chiu, Fang-Yao; Chang, Ming-Chau; Chen, Tain-Hsiung

    2007-01-01

    We evaluate the effect of reconstructing huge defects (mean, 15.8 cm) of the distal femur with Ilizarov's distraction osteogenesis and free twin-barreled vascularized fibular bone graft (TVFG). We retrospectively reviewed a consecutive series of five patients who had cases of distal femoral fractures with huge defects and infection that were treated by the Ilizarov's distraction osteogenesis. After radical debridement, two of the five cases had free TVFG and monolocal distraction osteogenesis, and another two cases had multilocal distraction osteogenesis with knee fusion because of loss of the joint congruity. The other case with floating knee injury had bilocal distraction osteogenesis and a preserved knee joint. The mean defect of distal femur was 15.8 cm (range, 14-18 cm) in length. The mean length of distraction osteogenesis by Ilizarov's apparatus was 8.2 cm. The mean length of TVFG was 8 cm. The average duration from application of Ilizarov's apparatus to achievement of bony union was 10.2 months (range, 8-13 months). At the end of the follow-up, ranges of motion of three knees were 0 to 45 degrees, 0 to 60 degrees, and 0 to 90 degrees. Two cases had knee arthrodesis with bony fusion because of loss of the joint congruity. There were no leg length discrepancies in all five patients. In addition, three patients had pin tract infections and one case had a 10 degree varus deformity of the femur. Juxta-articular huge defect (>10 cm) of distal femur remains a challenge to orthopedic surgeons. Ilizarov's technique provides the capability to maintain stability, eradicate infection, restore leg length, and to perform adjuvant reconstructive procedure easily. In this study, we found that combining Ilizarov's distraction osteogenesis with TVFG results in improved patient outcome for patients with injuries such as supracondylar or intercondylar infected fractures or nonunion of distal femur with huge bone defect.

  20. Associations between inadequate knee function detected by KOOS and prospective graft failure in an anterior cruciate ligament-reconstructed knee.

    Science.gov (United States)

    Granan, Lars-Petter; Baste, Valborg; Engebretsen, Lars; Inacio, Maria C S

    2015-04-01

    First, to evaluate whether the 2 year post-operative Knee injury and Osteoarthritis Outcome Score (KOOS) in primary anterior cruciate ligament reconstructions (ACLRs) was significantly different between patients that did not go on to have a subsequent revision after the 2 year post-operative control and the ones that did. Second, to test whether the "clinically failure" value of KOOS quality of life (QoL) < 44 was indicative of a clinically relevant difference in the risk of subsequent revision ACLR. ACLRs reported to the Norwegian Knee Ligament Registry between June 2004 and December 2009. 5,517 primary ACLRs with at least 2-year follow-up with KOOS QoL before revision surgery. There were clinically significant differences, adjusted and unadjusted, in both the KOOS Sport and Recreation and QoL subscales in patients with a later revision surgery compared to those that did not have a revision surgery. In adjusted models, the risk of later ACLR revision was 3.7 (95 % CI 2.2-6.0) higher in patients with a 2-year KOOS QoL < 44 compared to patients with a KOOS QoL ≥ 44. For every 10-point reduction in the KOOS QoL, a 33.6 % (95 % CI 21.2-47.5 %) higher risk for later ACLR revision was observed. This study reveals an association between inadequate knee function, as measured by KOOS, and a prospective ACL-reconstructed graft failure. Prognostic study (prospective cohort study), Level II.

  1. Breast reconstruction using dermoglandular flaps and fat grafting following the resection of unilateral giant fibrocystic changes

    Directory of Open Access Journals (Sweden)

    Ismail Kucuker

    2017-06-01

    Full Text Available Giant benign breast masses have been reported in the literature. Most of these reports are lipomas and fibroadenomas. Fibrocystic breast disease is also very common but has not been described as a giant mass in the breast as of yet. It can also be seen with fibroadenosis combined with micro- and macro-cyst formations. In this study, the aim was to present two-stage reconstructive management to restore a severe breast asymmetry caused by a rare benign lesion. A 39-year-old woman with unilateral asymmetry in her breast was admitted to the clinic. Preoperative USG revealed fibroglandular tissue in her right breast but did not show a well-circumscribed mass. It also showed micro- and macro-cysts. It was concluded that in case of severe breast asymmetry, a combination of different techniques is required. [Arch Clin Exp Surg 2017; 6(2.000: 100-103

  2. Effect of graft choice on the outcome of revision anterior cruciate ligament reconstruction in the Multicenter ACL Revision Study (MARS) Cohort

    Science.gov (United States)

    Wright, Rick W.; Huston, Laura J.; Haas, Amanda K.; Spindler, Kurt P.; Nwosu, Sam K.; Allen, Christina R.; Anderson, Allen F.; Cooper, Daniel E.; DeBerardino, Thomas M.; Dunn, Warren R.; Lantz, Brett (Brick) A.; Stuart, Michael J.; Garofoli, Elizabeth A.; Albright, John P.; Amendola, Annunziato (Ned); Andrish, Jack T.; Annunziata, Christopher C.; Arciero, Robert A.; Bach, Bernard R.; Baker, Champ L.; Bartolozzi, Arthur R.; Baumgarten, Keith M.; Bechler, Jeffery R.; Berg, Jeffrey H.; Bernas, Geoffrey A.; Brockmeier, Stephen F.; Brophy, Robert H.; Bush-Joseph, Charles A.; Butler, J. Brad; Campbell, John D.; Carey, James L.; Carpenter, James E.; Cole, Brian J.; Cooper, Jonathan M.; Cox, Charles L.; Creighton, R. Alexander; Dahm, Diane L.; David, Tal S.; Flanigan, David C.; Frederick, Robert W.; Ganley, Theodore J.; Gatt, Charles J.; Gecha, Steven R.; Giffin, James Robert; Hame, Sharon L.; Hannafin, Jo A.; Harner, Christopher D.; Harris, Norman Lindsay; Hechtman, Keith S.; Hershman, Elliott B.; Hoellrich, Rudolf G.; Hosea, Timothy M.; Johnson, David C.; Johnson, Timothy S.; Jones, Morgan H.; Kaeding, Christopher C.; Kamath, Ganesh V.; Klootwyk, Thomas E.; Levy, Bruce A.; Ma, C. Benjamin; Maiers, G. Peter; Marx, Robert G.; Matava, Matthew J.; Mathien, Gregory M.; McAllister, David R.; McCarty, Eric C.; McCormack, Robert G.; Miller, Bruce S.; Nissen, Carl W.; O'Neill, Daniel F.; Owens, Brett D.; Parker, Richard D.; Purnell, Mark L.; Ramappa, Arun J.; Rauh, Michael A.; Rettig, Arthur C.; Sekiya, Jon K.; Shea, Kevin G.; Sherman, Orrin H.; Slauterbeck, James R.; Smith, Matthew V.; Spang, Jeffrey T.; Svoboda, Steven J.; Taft, Timothy N.; Tenuta, Joachim J.; Tingstad, Edwin M.; Vidal, Armando F.; Viskontas, Darius G.; White, Richard A.; Williams, James S.; Wolcott, Michelle L.; Wolf, Brian R.; York, James J.

    2015-01-01

    Background Most surgeons believe that graft choice for ACL reconstruction is an important factor related to outcome. Although graft choice may be limited in the revision setting based on previously used grafts, it is still felt to be important. Hypothesis The purpose of this study was to determine if revision ACL graft choice predicts outcomes related to sports function, activity level, OA symptoms, graft re-rupture, and reoperation at two years following revision reconstruction. We hypothesized that autograft use would result in increased sports function, increased activity level, and decreased OA symptoms (as measured by validated patient reported outcome instruments). Additionally, we hypothesized that autograft use would result in decreased graft failure and reoperation rate 2 years following revision ACL reconstruction. Study Design Prospective cohort study; Level of evidence, 2. Methods Revision ACL reconstruction patients were identified and prospectively enrolled by 83 surgeons over 52 sites. Data collected included baseline demographics, surgical technique and pathology, and a series of validated patient reported outcome instruments (IKDC, KOOS, WOMAC, and Marx activity rating score). Patients were followed up at 2 years, and asked to complete the identical set of outcome instruments. Incidence of additional surgery and reoperation due to graft failure were also recorded. Multivariate regression models were used to determine the predictors (risk factors) of IKDC, KOOS, WOMAC, Marx scores, graft re-rupture, and reoperation rate at 2 years following revision surgery. Results 1205 patients were successfully enrolled with 697 (58%) males. Median age was 26. In 88% this was their first revision. 341 (28%) were undergoing revision by the surgeon that had performed the previous reconstruction. 583 (48%) underwent revision reconstruction utilizing an autograft, 590 (49%) allograft, and 32 (3%) both autograft and allograft. Median time since their last ACL

  3. [Necrotizing fasciitis of the hand and forearm : Acute surgical treatment and defect reconstruction with MatriDerm® and split-thickness skin graft].

    Science.gov (United States)

    Niedermueller, B; Singer, G; Pickl, P; Jesacher, M

    2018-03-01

    This case report describes a 55-year-old male patient with type II necrotizing fasciitis (NF) of the hand and forearm. The rapid progression of the tissue infection could be successfully stopped with radical surgical débridement and antibiotic therapy. For the reconstruction of the extensive loss of soft tissue a combination of split-thickness skin graft (STSG) and the synthetic dermal substitute MatriDerm® was used. In cases of NF, MatriDerm® and STSG provide a rapidly available and simple alternative to other reconstruction techniques.

  4. Acromioclavicular joint dislocation: a comparative biomechanical study of the palmaris-longus tendon graft reconstruction with other augmentative methods in cadaveric models

    Directory of Open Access Journals (Sweden)

    Sengupta S

    2007-11-01

    Full Text Available Abstract Background Acromioclavicular injuries are common in sports medicine. Surgical intervention is generally advocated for chronic instability of Rockwood grade III and more severe injuries. Various methods of coracoclavicular ligament reconstruction and augmentation have been described. The objective of this study is to compare the biomechanical properties of a novel palmaris-longus tendon reconstruction with those of the native AC+CC ligaments, the modified Weaver-Dunn reconstruction, the ACJ capsuloligamentous complex repair, screw and clavicle hook plate augmentation. Hypothesis There is no difference, biomechanically, amongst the various reconstruction and augmentative methods. Study Design Controlled laboratory cadaveric study. Methods 54 cadaveric native (acromioclavicular and coracoclavicular ligaments were tested using the Instron machine. Superior loading was performed in the 6 groups: 1 in the intact states, 2 after modified Weaver-Dunn reconstruction (WD, 3 after modified Weaver-Dunn reconstruction with acromioclavicular joint capsuloligamentous repair (WD.ACJ, 4 after modified Weaver-Dunn reconstruction with clavicular hook plate augmentation (WD.CP or 5 after modified Weaver-Dunn reconstruction with coracoclavicular screw augmentation (WD.BS and 6 after modified Weaver-Dunn reconstruction with mersilene tape-palmaris-longus tendon graft reconstruction (WD. PLmt. Posterior-anterior (horizontal loading was similarly performed in all groups, except groups 4 and 5. The respective failure loads, stiffnesses, displacements at failure and modes of failure were recorded. Data analysis was carried out using a one-way ANOVA, with Student's unpaired t-test for unpaired data (S-PLUS statistical package 2005. Results Native ligaments were the strongest and stiffest when compared to other modes of reconstruction and augmentation except coracoclavicular screw, in both posterior-anterior and superior directions (p WD.ACJ provided additional

  5. Satisfactory knee function after single-stage posterolateral corner reconstruction in the multi-ligament injured/dislocated knee using the anatomic single-graft technique.

    Science.gov (United States)

    Sanders, Thomas L; Johnson, Nick R; Pareek, Ayoosh; Krych, Aaron J; Marx, Robert G; Stuart, Michael J; Levy, Bruce A

    2018-04-01

    Increasing importance has been placed on the posterolateral corner (PLC) in maintaining varus and rotational stability of the knee. The goal of this study was to evaluate knee function and clinical stability following a single-graft PLC reconstruction technique and identify factors associated with poor knee function. This study identified patients with a multi-ligament knee injury between 2006 and 2013. Patients who received a single-graft fibular collateral ligament and PLC reconstruction with a single-stage surgery during the study period and had a minimum follow-up of 2 years after surgery were included. Functional outcomes were assessed using Lysholm and IKDC scores. Varus and rotational knee laxity and range of motion were assessed using physical examination. The final study cohort included 61 patients who underwent PLC reconstruction using a single-graft technique. The mean IKDC score was 74.1 (± 22.3) and the mean Lysholm score was 80.3 (± 21.8) at mean follow-up of 3.8 years (range 2-9 years). Mean range of motion at final follow-up measured from 0° to 126° [range flexion: 95-145, range extension: 0-5]. Fifty-eight patients (95%) had grade 0 varus laxity in full knee extension, and 54 patients (88.5%) had grade 0 varus laxity at 30° of knee flexion. Female gender was associated with a lower postoperative IKDC score (p = 0.04). Surgical treatment of the PLC using a single-graft technique can result in satisfactory knee function and stable physical examination findings at minimum 2 years after surgery. Female gender was predictive of poor knee function after PLC reconstruction. Surgical treatment of PLC injuries should be individualized based on the timing of surgery, specific injured knee structures, and physical examination findings. This study helps validate the use of a single-graft technique for PLC reconstruction and can be used to help counsel patients about expected knee function after surgical treatment of PLC injuries. Level of evidence

  6. [EFFECTIVENESS COMPARISON OF CORACOCLAVICULAR LIGAMENT RECONSTRUCTION BETWEEN BY AUTOLOGOUS AND ALLOGENEIC TENDON GRAFTS COMBINED WITH HOOK PLATE FIXATION FOR TREATING ACROMIOCLAVICULAR JOINT DISLOCATION].

    Science.gov (United States)

    Yin, Fei; Sun, Zhenzhong; Wei, Xuming; Liu, Xueguang; Zhou, Ming; Zhuang, Yin; Song, Sheng

    2016-05-08

    To compare the effectiveness of coracoclavicular ligament reconstruction between by using autologous plantaris tendon graft combined with hook plate fixation and allogeneic tendon graft combined with hook plate fixation for treating acromiocavicular joint dislocation. Thirty-three patients with acromioclavicular joint dislocation who accorded with the inclusion criteria between January 2013 and June 2014 were assigned into 2 groups. The patients were treated with autologous plantaris tendon graft combined with hook plate fixation in group A ( n =17), and with allogeneic tendon graft combined with hook plate fixation in group B ( n =16). Thirteen-one patients was followed up more than 12 months (15 in group A and 16 in group B). There was no significant difference in gender, age, cause of injury, sides, time between injury and surgery, and type of dislocation ( P >0.05). The assessments included operation time, hospitalization time, hospitalization expenses, shoulder range of motion, gap of acromioclavicular, Constant-Murley scores, and visual analogue scale (VAS) for pain. The operation time of group A was significantly longer than that of group B, and the hospitalization expense was significantly lower than that of group B ( P 0.05). No redislocation of acromioclavicular joint and rejection reaction occurred during follow-up. At last follow-up, there was no significant difference in shoulder range of motion, Constant-Murley score, and VAS score between 2 groups ( P >0.05). Coracoclavicular ligament reconstruction by autologous plantaris tendon or allogeneic tendon graft combined with hook plate fixation for the treatment of acromioclavicular joint dislocation can achieve good effectiveness. The appropriate treatment should be chosen according to the patient's economic situation.

  7. Does well maintained graft provide consistent return to play after medial ulnar collateral ligament reconstruction of the elbow joint in elite baseball players?

    Science.gov (United States)

    Park, Jin-Young; Oh, Kyung-Soo; Bahng, Seung-Chul; Chung, Seok-Won; Choi, Jin-Ho

    2014-06-01

    Several studies have reported the clinical outcomes of medial ulnar collateral ligament (MUCL) reconstruction of the elbow joint in throwing athletes, including the rate of return to sports. However, little has been known about the imaging outcomes after MUCL reconstruction. The aim of this study is to report the clinical and imaging outcomes after MUCL reconstruction using figure of eight fashion in the elite and professional baseball players. This study included 17 baseball players, who underwent MUCL reconstruction between July 2007 and May 2010. The average follow-up period was 48.6 months. Imaging assessment consisted of preoperative plain and stress radiographs, magnetic resonance imaging, and postoperative serial ultrasonography. The clinical assessments were composed of visual analogue scale (VAS) for pain, range of motion, and the Conway scale. The mean VAS score was 6.4 (range, 3 to 8) preoperatively and 2.2 (range, 0 to 4) postoperatively (p returned to sports at the same or higher level compared to preinjury. Serial ultrasonography revealed well-maintained grafts at 3 and 12 months in all of the players. Five out of 17 players showed decreased echogenecity in the common flexor tendon at 3 months, which was considered as remaining tissue swelling and resolved completely at 12 months. All grafts are well-maintained until 12-months based on the ultrasonographic findings, although only 53% of the players returned to preinjury level.

  8. The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.

    Science.gov (United States)

    Akamaru, Tomoyuki; Kawahara, Norio; Sakamoto, Jiro; Yoshida, Akira; Murakami, Hideki; Hato, Taizo; Awamori, Serina; Oda, Juhachi; Tomita, Katsuro

    2005-12-15

    A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total spondylectomy. The most recent reconstruction techniques following total spondylectomy for malignant spinal tumor include a titanium mesh cage filled with autologous bone as an anterior strut. The need for additional anterior instrumentation with posterior pedicle screws and rods is controversial. Transmission of the mechanical stress to grafted bone inside a titanium mesh cage is important for fusion and remodeling. To our knowledge, there are no published reports comparing the load-sharing properties of the different reconstruction methods following total spondylectomy. A 3-dimensional finite-element model of the reconstructed spine (T10-L4) following total spondylectomy at T12 was constructed. A Harms titanium mesh cage (DePuy Spine, Raynham, MA) was positioned as an anterior replacement, and 3 types of the reconstruction methods were compared: (1) multilevel posterior instrumentation (MPI) (i.e., posterior pedicle screws and rods at T10-L2 without anterior instrumentation); (2) MPI with anterior instrumentation (MPAI) (i.e., MPAI [Kaneda SR; DePuy Spine] at T11-L1); and (3) short posterior and anterior instrumentation (SPAI) (i.e., posterior pedicle screws and rods with anterior instrumentation at T11-L1). The mechanical energy stress distribution exerted inside the titanium mesh cage was evaluated and compared by finite-element analysis for the 3 different reconstruction methods. Simulated forces were applied to give axial compression, flexion, extension, and lateral bending. In flexion mode, the energy stress distribution in MPI was higher than 3.0 x 10 MPa in 73.0% of the total volume inside

  9. Functional Outcome and Graft Retention in Patients With Septic Arthritis After Anterior Cruciate Ligament Reconstruction: A Systematic Review.

    Science.gov (United States)

    Makhni, Eric C; Steinhaus, Michael E; Mehran, Nima; Schulz, Brian S; Ahmad, Christopher S

    2015-07-01

    To provide a comprehensive review of clinical and functional outcomes after treatment for septic arthritis after anterior cruciate ligament reconstruction. A systematic review of the literature was performed. Two reviewers assessed and confirmed the methodologic quality of each study. Studies that met the inclusion criteria were assessed for pertinent data, and when available, similar outcomes were combined to generate frequency-weighted means. Nineteen studies met the inclusion and exclusion criteria for this review, reporting on a total of 203 infected knees. The mean age was 27.5 years and the mean length of follow-up was 44.2 months, with male patients comprising 88% of the population. Hamstring and bone-patellar tendon-bone autografts were used in 63% and 33% of patients, respectively, with 78% of patients retaining their grafts. The studies reported mean flexion and extension deficits of 5.8° and 1.0°, respectively, and laxity testing showed a mean difference of 1.9 mm. The studies reported mean Lysholm, International Knee Documentation Committee, and Tegner scores of 82.1, 68.2, and 5.6, respectively. Of the patients, 83% reported an ability to return to activities of daily living whereas 67% reported a return to their preinjury level of athletics. Evidence of new degenerative changes was seen in 22% of patients. Septic arthritis after anterior cruciate ligament reconstruction remains a very infrequent event, affecting 0.5% of patients. On average, outcomes in these patients are comparable with those in patients in whom infection does not develop, including postoperative range of motion, residual instability, Lysholm scores, and return to preinjury level of activity. These patients do exhibit decreased International Knee Documentation Committee scores compared with patients without septic arthritis, however. The impact of this differential is not clear, but this scoring difference suggests that septic arthritis may be associated with more severe symptoms

  10. Management of chest deformity caused by microtia reconstruction: Comparison of autogenous diced cartilage versus cadaver cartilage graft partial filling techniques.

    Science.gov (United States)

    Go, Ju Young; Kang, Bo Young; Hwang, Jin Hee; Oh, Kap Sung

    2017-01-01

    Efforts to prevent chest wall deformity after costal cartilage graft are ongoing. In this study, we introduce a new method to prevent donor site deformation using irradiated cadaver cartilage (ICC) and compare this method to the autogenous diced cartilage (ADC) technique. Forty-two pediatric patients comprised the ADC group (n = 24) and the ICC group (n = 18). After harvesting costal cartilage, the empty perichondrial space was filled with autologous diced cartilage in the ADC group and cadaver cartilage in the ICC group. Digital photographs and rib cartilage three-dimensional computed tomography (CT) data were analyzed to compare the preventive effect of donor site deformity. We compared the pre- and postoperative costal cartilage volumes using 3D-CT and graded the volumes (grade I: 0%-25%, grade II: 25%-50%, grade III: 50%-75%, and grade IV: 75%-100%). The average follow-up period was 20 and 24 months in the ADC and ICC groups, respectively. Grade IV maintenance of previous costal cartilage volume was evident postoperatively in 22% of patients in the ADC group and 82% of patients in the ICC group. Intercostal space narrowing and chest wall depression were less in the ICC group. There were no complications or severe resorption of cadaver cartilage. ICC support transected costal ring and prevented stability loss by acting as a spacer. The ICC technique is more effective in preventing intercostal space narrowing and chest wall depression than the ADC technique. Samsung Medical Center Institution Review Board, Unique protocol ID: 2009-10-006-008. This study is also registered on PRS (ClinicalTrials.gov Record 2009-10-006). Copyright © 2016 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  11. Comparison of knee flexion isokinetic deficits between seated and prone positions after ACL reconstruction with hamstrings graft: Implications for rehabilitation and return to sports decisions.

    Science.gov (United States)

    Koutras, Georgios; Bernard, Manfred; Terzidis, Ioannis P; Papadopoulos, Pericles; Georgoulis, Anastasios; Pappas, Evangelos

    2016-07-01

    Hamstrings grafts are commonly used in ACL reconstruction, however, the effect of graft harvesting on knee flexion strength has not been longitudinally evaluated in functional positions. We hypothesized that greater deficits in knee flexion strength exist in the prone compared to the seated position and these deficits remain as rehabilitation progresses. Case series. Forty-two consecutive patients who underwent ACL reconstruction with a hamstrings graft were followed prospectively for 9 months. Isokinetic knee flexion strength at a slow and a fast speed were collected at 3, 4, 6, and 9 months in two different positions: conventional (seated) and functional (0° of hip flexion). Peak torque knee flexion deficits were higher in the prone position compared to the seated position by an average of 6.5% at 60°/s and 9.1% at 180°/s (p<0.001). Measuring knee flexion strength in prone demonstrates higher deficits than in the conventional seated position. Most athletes would not be cleared to return to sports even at 9 months after surgery with this method. Copyright © 2015 Sports Medicine Australia. Published by Elsevier Ltd. All rights reserved.

  12. Comparação da perviedade entre artéria radial e veia safena em pacientes em pós-operatório de cirurgia de revascularização miocárdica com retorno dos sintomas Comparison of patency between radial artery and saphenous vein in a coronary artery bypass grafting post operative with return of the symptoms

    Directory of Open Access Journals (Sweden)

    Herbert Coelho Hortmann

    2010-06-01

    Full Text Available OBJETIVO: Comparar a perviedade da artéria radial e veia safena em pacientes com retorno dos sintomas após cirurgia de revascularização do miocárdio (CRVM. MÉTODOS: Estudo retrospectivo. No período de janeiro de 1998 a dezembro de 2005, foram realizadas 469 CRVMs com o uso da artéria radial dentre os enxertos, no Hospital Vera Cruz, em Belo Horizonte/MG. Destes, 94 pacientes apresentaram alterações isquêmicas no pós-operatório recente ou tardio e foram reestudados com cineangiocoronariografia. Os enxertos foram divididos em três grupos: artéria torácica interna (ATI, artéria radial (AR e veia safena (VS, e foram estratificados segundo a gravidade das lesões: sem lesão grave (OBJECTIVE: To compare the radial artery and saphenous vein's patency in patients with recurrence of symptoms in a coronary artery bypass grafting (CABG. METHODS: Retrospective study. From January 1998 to December 2005, 469 CABGs were performed using the radial artery as a graft, in Vera Cruz Hospital in Belo Horizonte/ MG. Among the patients who underwent those surgeries, 94 presented ischemic changes in early or late postoperative period, which led them to be re-evaluated by coronary angiography. The grafts were divided in three groups: internal thoracic artery (ITA, radial artery (RA and saphenous vein (SV, and they were stratified according to the severity of injury: uninjured or patent (< 70%, severe obstruction (70 to 99% and occlusion. RESULTS: For the 94 patients in the study, 86 grafts of ITA, 94 of RA and 111 of SV were used. For the 86 ITA grafts, 73 (84.88% were found patent. For the 94 RA grafts, 55 (58.51% were found patent, and for the 111 SV grafts, 73 (65.76% were uninjured. A statistically significant difference (P= 0.001 was found between RA and SV grafts, with a higher patency found for VS graft. For the RA grafts, women presented a worse result concerning the RA patency (65.7% and 40.7%, with P = 0.006. Concerning coronary

  13. One-stage treatment and reconstruction of Gustilo Type III open tibial shaft fractures with a vascularized fibular osteoseptocutaneous flap graft.

    Science.gov (United States)

    Zhen, Ping; Hu, Yun-Yu; Luo, Zhuo-Jing; Liu, Xing-Yan; Lu, Hao; Li, Xu-Sheng

    2010-12-01

    This study evaluated the usefulness of a single-stage, free-fibular vascularized osteoseptocutaneous flap transfer for Type III open tibial shaft fractures with segmental bone loss for the reconstruction of combined bone and soft tissue defects. Nonrandomized retrospective study. University Level I trauma center. All Gustilo Type III open tibial shaft fractures with segmental bone loss that were treated at one institution between 2000 and 2007 were identified from a trauma registry. The study group consisted of 28 patients with Type III open tibial fractures: 27 were Gustilo-Anderson Type IIIB and one was Grade IIIC. The cause of tibial injury included eight industrial accidents, seven motor vehicle accidents, five crushing injuries caused by heavy objects, five falls from a height, and three motorcycle crashes. The lengths of the preoperative segmental tibial bone loss ranged from 9 to 17 cm and the size of the associated soft tissue defects ranged from 8 × 6 cm to 15 × 7 cm. The free fibular vascularized osteoseptocutaneous flap was used to graft and reconstruct combined bone and soft tissue defects. The radical wound débridement, soft tissue and bone revision, fracture stabilization, and early soft tissue coverage were achieved by this technique in a one-stage procedure. The average duration from injury to one-stage reconstruction was 15.8 hours (range, 5.3 hours to 6.5 days). Radiographic and functional evaluation of the lower extremity. All free fibular osteoseptocutaneous flaps survived completely. The average time to overall union for the entire group was 32 weeks after surgery (range, 26-41 weeks). None of the patients in this series had a nonunion. Acceptable radiographic alignment, defined as 5° of angulation in any plane, was obtained in 22 patients (78.6%). Malunion affected six (21.4%) fractures. According to the lower extremity functional assessment, excellent and good results were achieved for 82.1% (23 of 28), fair results were seen in 14

  14. ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION: A COMPARISON BETWEEN BONE PATELLAR TENDON BONE GRAFT AND LIPSCOMB PROCEDURE - A FOLLOWUP STUDY OF 7 YEARS

    Directory of Open Access Journals (Sweden)

    Vijayamohan S

    2016-07-01

    Full Text Available BACKGROUND Anterior Cruciate Ligament injury has become more common and the demand by the patients to return to pre-injury level of activity has made reconstruction of the ligament very crucial. Though there are various techniques in reconstructing the anterior cruciate ligament, in this study, we compare two most commonly used techniques to see whether there is any significant difference in the outcome. METHODS Study included 25 patients in the age group of 19-36 years, of which 23 were males. The patients were divided randomly into 2 groups, and 15 patients underwent Anterior Cruciate Ligament reconstruction using Bone Patellar Tendon Bone Graft and 10 patients had Hamstring graft. RESULTS Patients were followed up at regular intervals monthly for the first six months and then at three monthly intervals. Patients were assessed using Knee Scoring Scale of Lysholm and Gillquist and International Knee Documentation Committee (IKDC scoring system. In addition, activity level, harvest site pain, thigh atrophy, kneeling pain and hamstring pain were assessed. All patients were followed up for a minimum period of 2 years. 20% of both groups were able to return to strenuous activity level, and 67% of Patellar tendon group and 50% of the Hamstring tendon group were able to return to moderate level of activity. 55% of patients in the patellar tendon group and 20% of patients in the hamstring tendon group had donor site pain in the first 6 months. 73% of patients in the hamstring group had at least 10 mm of thigh wasting. Pain on kneeling was seen only in the patellar tendon group (35% while hamstring pain was found only in the hamstring group (20%. CONCLUSIONS Patients in the patellar tendon group had increased anterior stability and were able to return to strenuous occupation. The difference in thigh atrophy between the two groups was not significant. The hamstring group had lower graft harvest site morbidity. Lachman test was the single most accurate

  15. Bioresorbable pins and interference screws for fixation of hamstring tendon grafts in anterior cruciate ligament reconstruction surgery: a randomized controlled trial.

    Science.gov (United States)

    Stengel, Dirk; Casper, Dirk; Bauwens, Kai; Ekkernkamp, Axel; Wich, Michael

    2009-09-01

    Biodegradable cross-pins have been shown to provide higher failure loads than do screws for fixation of hamstring tendons under laboratory conditions. To compare the clinical results of biodegradable pins (RigidFix) and interference screws (BioCryl) for fixation of hamstring grafts in arthroscopically assisted anterior cruciate ligament reconstruction. Study Design Randomized controlled trial; Level of evidence, 1. To test the hypothesis of a difference of 1.0 +/- 1.2 mm in anterior knee laxity between the two fixation options, 54 patients were randomly assigned to groups via a block randomization scheme and sealed envelopes. All patients underwent standardized hamstring graft reconstruction and had similar postoperative aftercare by an accelerated rehabilitation protocol. Measures assessed at baseline and after 1 and 2 years of follow-up included (1) the side-to-side difference in anterior laxity (KT-1000 arthrometer), (2) Short Form 36 physical and mental component scores, and (3) the International Knee Documentation Committee form scores. After 1 and 2 years, 26 and 21 patients in the BioCryl group and 28 and 24 patients in the RigidFix group were available for follow-up examination. No significant difference was noted in instrumented anterior translation between BioCryl and RigidFix fixation: 1 year, 0.11 (95% CI, -0.60 to 0.82; P = .7537); 2 years, 0.33 (95% CI, -0.43 to 1.08 mm; P = .3849). Also, there were no significant differences in the mean physical and mental component scores and International Knee Documentation Committee form scores and in overall complication and surgical revision rates. A pin dislocation was classified as the sole procedure-specific serious adverse event. Bioresorbable pins do not provide better clinical results than do resorbable interference screws for hamstring graft fixation in anterior cruciate ligament reconstruction surgery.

  16. Injuries of the Portal Vein in Patients With Blunt Abdominal Trauma

    Science.gov (United States)

    Kremer, B.; Lloyd, D. M.; Meyer-Pannwitt, U.

    1993-01-01

    Between January 1987 and September 1991, 68 severely traumatized patients underwent emergency laparotomy because of blunt abdominal trauma. Intraoperatively, 54.4% of the patients had a major injury to one organ, 23.5% had injuries to two organs, 16.2% had injuries to three organs and 5.9% to four or more organs. Additionally, in 11.8% of these cases (n = 8) a major vascular injury (portal vein n = 5, vena cava n = 2, mesenteric root n = 1) was found. Injuries to the portal vein were always associated with complete rupture of the pancreas, requiring distal pancreatic resection in four cases and a duodenum preserving resection of the head of the pancreas in one. In two of these patients the portal vein had to be reconstructed with a Goretex prosthetic graft. Mortality was 14.7% for the whole group (n = 68) and 0% for patients with additional portal venous injuries. PMID:8489966

  17. Partial medial second toe pulp free flap and dermal substitute with skin graft for salvage reconstruction of a complete skin envelope degloving of the small finger.

    Science.gov (United States)

    Calafat, V; Strugarek, C; Montoya-Faivre, D; Dap, F; Dautel, G

    2018-04-04

    Skin envelope degloving of fingers are rare injuries that require rapid care and surgical treatment. Mostly caused by ring finger injuries, these traumas include bone, tendon and neurovascular pedicle damage. The authors present an unusual case of finger degloving limited exclusively to the skin envelope, without skeletal, tendinous or vascular lesion. This rare case of skin envelope degloving rendered microsurgical revascularization impossible. The authors report the results at 12 months following salvage reconstruction combining a partial second toe pulp free flap for the volar side and a dermal substitute with a thin skin graft for the dorsum. Copyright © 2018 Elsevier Masson SAS. All rights reserved.

  18. Implante de stent dentro de stent recém-implantado em ponte de veia safena para otimização do resultado angiográfico Stenting a stent in saphenous vein graft to optimize the angiographic result

    Directory of Open Access Journals (Sweden)

    Antonio Esteves Fº

    1998-03-01

    Full Text Available Mulher de 60 anos, com angina progressiva e revascularização do miocárdio, há oito anos, com ponte de veia safena para coronária direita e anastomose de artéria mamaria esquerda para artéria descendente anterior. Submetida a implante de stent Gianturco-Roubin II em terço proximal da ponte de veia safena para artéria coronária direita, com resultado insatisfatório pela persistência de lesão residual, provavelmente, decorrente de prolapso para dentro da luz de material aterosclerótico através dos coils. Foi implantado outro stent (Palmaz-Schatz biliar dentro do stent GRII com sucesso e ótimo resultado angiográfico. Um 2º stent Palmaz-Schatz biliar foi implantado em lesão distal no corpo da ponte, ultrapassando os dois stents, anteriormente implantados, com sucesso. Em algumas situações, implante de stent dentro de outro stent é recurso útil para otimização de resultado angiográfico do implante de um stent.A 60 year-old woman with progressive angina who had been submitted to saphenous bypass-graft to right coronary artery and a left mammary artery graft to anterior descending artery eight years previously, underwent implantation of a Gianturco Roubin II stent in the proximal third of the saphenous vein graft. The result was suboptimal by persistence of a residual stenosis probably due to prolapse of atherosclerotic material through the coil spaces. Another stent (Palmaz-Schatz biliar stent was implanted at the previously stented site with no residual stenosis. Another Palmaz-Schatz biliar stent was successfully implanted in the distal body of the graft to treat another lesion (passing through the previously stents without difficulty. Stenting a stent, in selected situations, is a useful tool to optimize the angiographic result of stent implantation.

  19. Effects of cilostazol and k-134 on reconstructive surgery using prosthetic grafts in the abdominal aorta of beagle dogs.

    Science.gov (United States)

    Inoue, Yoshinori; Sugano, Norihide; Jibiki, Masatoshi; Kudo, Toshifumi; Iwai, Takehisa

    2008-01-01

    Problems associated with prosthetic graft replacement are stenosis at the anastomosis site and thrombus formation on the inner surface. Cilostazol is known to have antiplatelet activity and inhibit vascular smooth muscle cell proliferation and neointima thickening. A cilostazol derivative, (-)-6-[3-[3-cyclopropyl-3-[(1R,2R)-2-hydroxycyclohexyl]ureido]-propoxy]-2-(1H)-quinolinone (K-134), has more potent anti-platelet activity and anti-neointimal thickening activity than cilostazol in the in-vitro platelet aggregation and in-vivo anti-hyperplastic activity assay. The aim of this study was to investigate effects of cilostazol and K-134 on thrombus formation and neointimal thickening at the site of prosthetic graft replacement. Beagle dogs underwent infrarenal abdominal aortic resection with straight Dacron graft replacement, which were allocated to the control, cilostazol, and K-134 groups. Two dogs were dead without confirming the cause of death. After 6 months, all dogs were necropsied. All prosthetic grafts were patent in each group. Ratios of red thrombus to prosthetic graft area were 0.3+/-6.4%, and 3.3+/-4.5% in the cilostazol and K-134 groups, respectively, which were significant different from that in the control group (24.4+/-16.8%). However, no clear difference was seen among the 3 groups with respect to neointimal thickness (control group, 0.70+/-0.13 mm; cilostazol group, 0.59+/-0.14 mm; K-134 group, 0.67+/-0.14 mm). Cilostazol and K-134 significantly inhibited thrombus formation on the inner surface of the prosthetic graft at 6 months after graft replacement. Neointimal thickening on the inner surface was slight even in control-group animals, and the effects of cilostazol and K-134 on such thickening were unclear.

  20. Sclerotherapy of Varicose Veins and Spider Veins

    Science.gov (United States)

    ... Index A-Z Sclerotherapy of Varicose Veins and Spider Veins Sclerotherapy uses injections from a very fine, ... Sclerotherapy? What is Sclerotherapy of Varicose Veins and Spider Veins? Sclerotherapy is a minimally invasive treatment used ...

  1. Reconstrução marginal de pálpebras utilizando enxerto de palato duro Margin eyelid reconstruction with hard palate graft

    Directory of Open Access Journals (Sweden)

    Tiana Gabriela Burmann

    2008-08-01

    Full Text Available OBJETIVO: Avaliar os benefícios e complicações do uso do palato duro na reconstrução de pálpebras inferiores acometidas por carcinomas basocelulares extensos. MÉTODOS: Revisão da literatura e descrição da técnica utilizada no Setor de Oculoplástica do Hospital Santa Casa de Porto Alegre. RESULTADOS: O enxerto de palato duro é um excelente substituto da lamela posterior na reconstrução palpebral, pois apresenta os benefícios da superfície mucosa, associado ao fato de atuar como suporte semi-rígido. CONCLUSÃO: A técnica de sanduíche utilizando palato duro mostrou-se eficiente, com um resultado estético e funcional bastante satisfatório.PURPOSE: To investigate the advantages and the complications of the use of hard palate graft in the reconstruction of the inferior eyelids with large basocelular carcinoma. METHODS: Review of specialized articles and report of the technique used in the Oculoplastic Department of the "Hospital Santa Casa de Porto Alegre". RESULTS: The hard palate graft is an excellent replacement for posterior lamellar defects in eyelid reconstruction, because it presents the benefit of a mucous layer in addition to a semirigid support. CONCLUSION: The sandwich technique using hard palate was shown to be efficient, with good functional and esthetic results.

  2. Inferior tendon graft to bone tunnel healing at the tibia compared to that at the femur after anterior cruciate ligament reconstruction

    International Nuclear Information System (INIS)

    Lui, P.P.Y.; Ho, G.; Shum, W.T.; Lee, Y.W.; Ho, P.Y.; Lo, W.N.; Lo, C.K.

    2010-01-01

    Tunnel widening after anterior cruciate ligament (ACL) reconstruction (ACLR) is commonly reported without a clear understanding of the mechanism. This study aimed to quantify the spatiotemporal change of the newly formed bone mass, bone tunnel diameter, and area along both bone tunnels using micro-computed tomography (μCT) and correlated the result with histology. ACLR was performed in 24 rabbits. At baseline and weeks 2, 6, and 12, the juxta-articular, middle, and exit segments of both tunnels were harvested for μCT and histological evaluation. μCT and histology revealed significant bone tunnel and graft-bone tunnel healing, respectively, only at week 6 after reconstruction. Despite this, the mean tunnel diameter and area remained relatively unchanged with time. The newly formed bone mass [new bone volume/total bone volume (BV/TV) ratio] and its bone mineral density (BMD) were both higher, whereas the mean tunnel diameter and area were significantly smaller at the femoral tunnel compared to those at the tibial tunnel at weeks 6 and 12 and at week 12, respectively. These were consistent with histological findings, which showed inferior graft remodeling and integration at the tibial tunnel at weeks 6 and 12. The BV/TV increased, whereas the mean tunnel diameter and area decreased toward the exit segment of both tunnels. However, whereas better histological healing occurred at the femoral exit segment, poorer graft remodeling and Sharpey's fiber formation occurred at the tibial exit segment. Poor healing was observed during the initial 6 weeks, particularly that of the tibia, after ACLR. Bone resorption was rapid during healing, resulting in unchanged tunnel diameter and area with time. (author)

  3. Random Pattern Vertically Oriented, Partial Thickness Buccinator Myomucosal Flap for Intraoral Reconstruction: A Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Amin Rahpeyma

    2016-05-01

    Full Text Available Introduction: Reconstruction of the oral cavity witha flap design containing the buccal mucosa and buccinator muscle but excluding the facial artery and vein is the topic of these case reports. Case Reports: This article uses random pattern vertically oriented partial thickness buccinator myomucosal flap for intraoral reconstruction in two cases. The first was for lining the mandibular anterior vestibule in a trauma patient. The second was for oral side coverage of bone graft in special cleft patient. In both patients, this flap survived and good bone coverage with non-keratinized mucosa was obtained. Conclusion:  Thin long buccal myomucosal flap not including facial artery and vein can survive.

  4. Reconstruction of mandibular defects after radiation, using a free, living bone, graft transferred by microvascular anastomoses. An experimental study

    International Nuclear Information System (INIS)

    Ostrup, L.T.; Fredrickson, J.M.

    1975-01-01

    The replacement of a mandibular defect by a free, composite rib graft, transferred by microvascular anastomoses of the posterior intercostal vessels to donor vessels in the neck was described previously. We now present data which demonstrate that successful results can be achieved even after radical mandibular radiation. This technique, done in dogs, has obvious implications in the management of oral cancer in man

  5. ACL graft re-rupture after double-bundle reconstruction: factors that influence the intra-articular pattern of injury

    NARCIS (Netherlands)

    van Eck, Carola F.; Kropf, Eric J.; Romanowski, James R.; Lesniak, Bryson P.; Tranovich, Michael J.; van Dijk, C. Niek; Fu, Freddie H.

    2011-01-01

    To determine the most common rupture patterns of previously reconstructed DB-ACL cases, seen at the time of revision surgery, and to determine the influence of age, gender, time between the initial ACL reconstruction and re-injury, tunnel angle and etiology of failure. Forty patients who presented

  6. Sensory nerve function and auto-mutilation after reconstruction of various gap lengths with nerve guides and autologous nerve grafts

    NARCIS (Netherlands)

    den Dunnen, WFA; Meek, MF

    The aim of this study was to evaluate sensory nerve recovery and auto-mutilation after reconstruction of various lengths of nerve gaps in the sciatic nerve of the rat, using different techniques. Group 4, in which the longest nerve gap (15 mm) was reconstructed with a thin-walled

  7. Bone graft revascularization strategies

    NARCIS (Netherlands)

    Willems, W.F.

    2014-01-01

    Reconstruction of avascular necrotic bone by pedicled bone grafting is a well-known treatment with little basic research supporting its application. A new canine model was used to simulate carpal bone avascular necrosis. Pedicled bone grafting proved to increase bone remodeling and bone blood flow,

  8. Surgical Treatment of Subungual Squamous Cell Carcinoma by Wide Excision of the Nail Unit and Skin Graft Reconstruction: An Evaluation of Treatment Efficiency and Outcomes.

    Science.gov (United States)

    Topin-Ruiz, Solène; Surinach, Catherine; Dalle, Stéphane; Duru, Gérard; Balme, Brigitte; Thomas, Luc

    2017-05-01

    The best surgical treatment modalities for subungual squamous cell carcinoma (SUSCC) without bone invasion need to be determined. The limited available data on Mohs micrographic surgery do not demonstrate its use as a standard procedure. A previous study in a limited series of patients has shown that wide surgical excision of the nail unit was associated with a low rate of recurrence. To confirm the efficiency of wide surgical excision of the nail unit with full-thickness skin graft reconstruction on a series of patients with SUSCC with an extended follow-up and to evaluate short- and long-term postoperative morbidity and patient satisfaction. A consecutive series of 55 patients with biopsy-proven SUSCC without bone invasion treated by wide surgical excision of the nail unit followed by full-thickness skin graft reconstruction from January 1, 2000, to August 31, 2012 were included. After a minimum follow-up of 5 years, the recurrences were collected from the referring physicians. Statistical analysis was conducted from January 1 to June 30, 2016. Demographic data, pathologic characteristics of tumors, postoperative follow-up, and recurrences were collected from medical records. Patients' satisfaction with surgery, quality of life, and delayed postoperative morbidity (functional outcome and sensory disorders) were assessed from a questionnaire mailed to patients and physicians. Among the 55 patients (23 women and 32 men; mean age, 64 years), the mean follow-up was 6.6 years (range, 5.0-11.2 years), with a minimum follow-up of 5 years. Fifty-two questionnaires (95%) were returned. Two recurrences were observed. Minor early postoperative complications, such as graft infection and delayed wound healing, were seen in 6 patients; 8 patients experienced severe pain. Late postoperative complications included hypersensitivity to mechanical shocks (39 of 51 patients [76%]), mildly increased sensitivity to cold (38 of 51 patients [75%]), loss of fine touch sensation (17 of 35

  9. Peak stresses shift from femoral tunnel aperture to tibial tunnel aperture in lateral tibial tunnel ACL reconstructions: a 3D graft-bending angle measurement and finite-element analysis.

    Science.gov (United States)

    Van Der Bracht, Hans; Tampere, Thomas; Beekman, Pieter; Schepens, Alexander; Devriendt, Wouter; Verdonk, Peter; Victor, Jan

    2018-02-01

    To investigate the effect of tibial tunnel orientation on graft-bending angle and stress distribution in the ACL graft. Eight cadaveric knees were scanned in extension, 45°, 90°, and full flexion. 3D reconstructions with anatomically placed anterior cruciate ligament (ACL) grafts were constructed with Mimics 14.12 ® . 3D graft-bending angles were measured for classic medial tibial tunnels (MTT) and lateral tibial tunnels (LTT) with different drill-guide angles (DGA) (45°, 55°, 65°, and 75°). A pivot shift was performed on 1 knee in a finite-element analysis. The peak stresses in the graft were calculated for eight different tibial tunnel orientations. In a classic anatomical ACL repair, the largest graft-bending angle and peak stresses are seen at the femoral tunnel aperture. The use of a different DGA at the tibial side does not change the graft-bending angle at the femoral side or magnitude of peak stresses significantly. When using LTT, the largest graft-bending angles and peak stresses are seen at the tibial tunnel aperture. In a classic anatomical ACL repair, peak stresses in the ACL graft are found at the femoral tunnel aperture. When an LTT is used, peak stresses are similar compared to classic ACL repairs, but the location of the peak stress will shift from the femoral tunnel aperture towards the tibial tunnel aperture. the risk of graft rupture is similar for both MTTs and LTTs, but the location of graft rupture changes from the femoral tunnel aperture towards the tibial tunnel aperture, respectively. I.

  10. Total venous inflow occlusion and pericardial auto-graft reconstruction for right atrial hemangiosarcoma resection in a dog

    Science.gov (United States)

    Verbeke, Fei; Binst, Dominique; Stegen, Ludo; Waelbers, Tim; de Rooster, Hilde; Van Goethem, Bart

    2012-01-01

    A sizeable right atrial hemangiosarcoma in a 6-year-old Bordeaux dog, World Health Organization (WHO) stage 2, was excised using total venous inflow occlusion. The defect was restored with a non-vascularized pericardial auto-graft. The dog had a disease-free interval of 7 mo. The dog was euthanized 9 months later, at which time there were distant metastases but no indication of local recurrence. PMID:23543933

  11. Thumb fingertip reconstruction with palmar V-Y flaps combined with bone and nail bed grafts following amputation.

    Science.gov (United States)

    Zhou, Xiao; Wang, Libo; Mi, Jingyi; Xu, Yajun; Rui, Yongjun; Xue, Mingyu; Shen, Xiaofang; Qiang, Li

    2015-04-01

    The aim of treating thumb fingertip amputations with no indication for replantation is to reestablish functional and esthetic properties. From March 2005 to October 2008, we treated 14 patients with thumb fingertip amputation using palmar V-Y flaps combined with bone and nail bed grafts. There were 10 men and 4 women, whose ages at surgery ranged from 19 to 63 years (mean 35.8 years). In all, 11 of the injuries occurred in the dominant hand. According to Allen's classification, two were type II, seven were type III, and five were type IV. All patients underwent emergency surgery, with a time delay after injury of 3-12 h (mean 6.4 h). In each case, the amputation was a crush or avulsion injury, making microsurgical replantation not feasible. All of the flaps survived. At 8-17 months (average 12.8 months) of follow-up, the average subjective satisfaction score was 8.64. All patients experienced cold intolerance, and none of the patients complained of dysesthesia. Favorable results (excellent or good) were found in 78.6%. Thin primary nails appeared on the grafted nail bed about 3 weeks after surgery, following which the newly formed nail thickened and developed a more natural appearance. In one case, the new nail plate showed abnormal thickening due to hyperkeratosis. The bone graft healed at 5 weeks. The mean two-point discrimination was 7.5 mm. Grip strength was 10% less than that in the unaffected hand. Metacarpophalangeal and proximal interphalangeal joint mobility losses were less than 10°. All patients returned to their jobs. No patients had postoperative complications. We believe that the combination of palmar V-Y flap and bone and nail bed grafts provides a distinct advantage over other choices. It improves function when replantation is not an option.

  12. Reconstruction of the Midfoot Using a Free Vascularized Fibular Graft After En Bloc Excision for Giant Cell Tumor of the Tarsal Bones: A Case Report.

    Science.gov (United States)

    Hara, Hitomi; Kawamoto, Teruya; Onishi, Yasuo; Fujioka, Hiroyuki; Nishida, Kotaro; Kuroda, Ryosuke; Kurosaka, Masahiro; Akisue, Toshihiro

    2016-01-01

    We report the case of a 32-year-old Japanese female with a giant cell tumor of bone involving multiple midfoot bones. Giant cell tumors of bone account for approximately 5% of all primary bone tumors and most often arise at the ends of long bones. The small bones, such as those of the hands and feet, are rare sites for giant cell tumors. Giant cell tumors of the small bones tend to exhibit more aggressive clinical behavior than those of the long bones. The present patient underwent en bloc tumor excision involving multiple tarsals and metatarsals. We reconstructed the longitudinal arch of the foot with a free vascularized fibular graft. At the 2-year follow-up visit, bony union had been achieved, with no tumor recurrence. Copyright © 2016 American College of Foot and Ankle Surgeons. Published by Elsevier Inc. All rights reserved.

  13. COMPARATIVE STUDY OF CLINICAL OUTCOME OF ARTHROSCOPIC ANTERIOR CRUCIATE LIGAMENT RECONSTRUCTION BONE PATELLAR TENDON BONE GRAFT V/S HAMSTRING GRAFT

    Directory of Open Access Journals (Sweden)

    Priyank

    2015-08-01

    fulfilling the predetermined inclusion and exclusion criteria were included in the study. STATISTICAL METHODS : Intergroup comparison was analysed by K - Independent sample t test. Intragroup comparison was analysed by Paired t - test. RESULTS : Patients were divided into two groups and treated with using Bone - patellar tendon - bone graft and Hamstring graft respectively. Mean age group of patients was 29.16 yrs. (range 16 - 51yrs and 30.88 yrs. (range 19 - 48yrs in group A and B respectively we found the incidence of ACL injury in 15 - 44 years age group to be greater than twice the general population. A mean delay in surgery of 4.66 months (range 2 - 12 months since the time of injury in group A and 4.46 months (range 2 - 7 months in group B was observed. Subjective IKDC evaluation was done at the end of 12 months. Ther e was no difference in both the groups in the terms of effusion, passive motion, knee compartment findings, ligament examination, X - ray findings. Functional test and IKDC grade of both the groups showed statistically very highly significant improvement. Ho wever, there was statistically very high Harvest site pathology in group A. CONCLUSION : We found that there is statistically no significant difference in the overall clinical outcome between hamstring autograft with transfix and bone - patellar tendon bone autograft with interference screw except that the patellar tendon group had a greater tendency of having donor site morbidity compared to the hamstring tendon group.

  14. Reconstruction of irradiated bone segmental defects with a biomaterial associating MBCP+(R), microstructured collagen membrane and total bone marrow grafting: an experimental study in rabbits.

    Science.gov (United States)

    Jégoux, Franck; Goyenvalle, Eric; Cognet, Ronan; Malard, Olivier; Moreau, Francoise; Daculsi, Guy; Aguado, Eric

    2009-12-15

    The bone tissue engineering models used today are still a long way from any oncologic application as immediate postimplantation irradiation would decrease their osteoinductive potential. The aim of this study was to reconstruct a segmental critical size defect in a weight-bearing bone irradiated after implantation. Six white New Zealand rabbits were immediately implanted with a biomaterial associating resorbable collagen membrane EZ(R) filled and micro-macroporous biphasic calcium phosphate granules (MBCP+(R)). After a daily schedule of radiation delivery, and within 4 weeks, a total autologous bone marrow (BM) graft was injected percutaneously into the center of the implant. All the animals were sacrificed at 16 weeks. Successful osseous colonization was found to have bridged the entire length of the defects. Identical distribution of bone ingrowth and residual ceramics at the different levels of the implant suggests that the BM graft plays an osteoinductive role in the center of the defect. Periosteum-like formation was observed at the periphery, with the collagen membrane most likely playing a role. This model succeeded in bridging a large segmental defect in weight-bearing bone with immediate postimplantation fractionated radiation delivery. This has significant implications for the bone tissue engineering approach to patients with cancer-related bone defects.

  15. A novel technique for impaction bone grafting in acetabular reconstruction of revision total hip arthroplasty using an ex vivo compaction device

    International Nuclear Information System (INIS)

    Akiyama, Haruhiko; Takemoto, Mitsuru; Morishima, Takkan

    2011-01-01

    Impaction bone grafting allows restoration of the acetabular bone stock in revision hip arthroplasty. The success of this technique depends largely on achieving adequate initial stability of the component. To obtain well-compacted, well-graded allograft aggregates, we developed an ex vivo compaction device to apply it in revision total hip arthroplasty on the acetabular side, and characterized mechanical properties and putative osteoconductivity of allograft aggregates. Morselized allograft bone chips were compacted ex vivo using the creep technique and subsequent impaction technique to form the bone aggregates. Impaction allograft reconstruction of the acetabulum using an ex vivo compaction device was performed on eight hips. The mechanical properties and three-dimensional micro-CT-based structural characteristics of the bone aggregates were investigated. In clinical practice, this technique offered good reproducibility in reconstructing the cavity and the segmental defects of the acetabulum, with no migration and no loosening of the component. In vitro analysis showed that the aggregates generated from 25 g fresh-frozen bone chips gained compression stiffness of 13.5-15.4 MPa under uniaxial consolidation strain. The recoil of the aggregates after compaction was 2.6-3.9%. The compression stiffness and the recoil did not differ significantly from those measured using a variety of proportions of large- and small-sized bone chips. Micro-CT-based structural analysis revealed average pore sizes of 268-299 μm and average throat diameter of pores in the bone aggregates of more than 100 μm. These sizes are desirable for osteoconduction, although large interconnected pores of more than 500 μm were detectable in association with the proportion of large-sized bone chips. Cement penetration into the aggregates was related to the proportion of large-sized bone chips. This study introduces the value of an ex vivo compaction device in bone graft compaction in clinical

  16. The short- and long-term outcomes of percutaneous intervention with drug-eluting stent vs bare-metal stent in saphenous vein graft disease: An updated meta-analysis of all randomized clinical trials.

    Science.gov (United States)

    Kheiri, Babikir; Osman, Mohammed; Abdalla, Ahmed; Ahmed, Sahar; Bachuwa, Ghassan; Hassan, Mustafa

    2018-05-11

    The use of drug-eluting stents (DES) vs bare-metal stents (BMS) in saphenous vein graft (SVG) lesions remains controversial. We conducted a meta-analysis of all randomized clinical trials comparing the outcomes of DES with BMS in SVG percutaneous coronary interventions. A search of PubMed, Embase, the Cochrane Register of Controlled Trials, and Clinicaltrials.gov was performed for all randomized clinical trials. We evaluated the short- and long-term clinical outcomes of the following: all-cause mortality, major adverse cardiovascular events (MACE), definite/probable stent thrombosis, target lesion revascularization (TLR), and target-vessel revascularization (TVR). From a total of 1582 patients in 6 randomized clinical trials, 797 had DES and 785 had BMS. Patients with DES had lower short-term MACE, TLR, and TVR in comparison with BMS (odds ratio [OR]: 0.56, 95% confidence interval [CI]: 0.35-0.91, P = 0.02; OR: 0.43, 95% CI: 0.19-0.99, P = 0.05; and OR: 0.45, 95% CI: 0.22-0.95, P = 0.04, respectively). However, there were no different outcomes for all-cause mortality (P = 0.63) or stent thrombosis (P = 0.21). With long-term follow-up, there were no significant reductions of MACE (P = 0.20), TLR (P = 0.57), TVR (P = 0.07), all-cause mortality (P = 0.29), and stent thrombosis (P = 0.76). The use of DES in SVG lesions was associated with lower short-term MACE, TLR, and TVR in comparison with BMS. However, there were no significant differences with long-term follow-up. © 2018 Wiley Periodicals, Inc.

  17. Augmented reality based real-time subcutaneous vein imaging system.

    Science.gov (United States)

    Ai, Danni; Yang, Jian; Fan, Jingfan; Zhao, Yitian; Song, Xianzheng; Shen, Jianbing; Shao, Ling; Wang, Yongtian

    2016-07-01

    A novel 3D reconstruction and fast imaging system for subcutaneous veins by augmented reality is presented. The study was performed to reduce the failure rate and time required in intravenous injection by providing augmented vein structures that back-project superimposed veins on the skin surface of the hand. Images of the subcutaneous vein are captured by two industrial cameras with extra reflective near-infrared lights. The veins are then segmented by a multiple-feature clustering method. Vein structures captured by the two cameras are matched and reconstructed based on the epipolar constraint and homographic property. The skin surface is reconstructed by active structured light with spatial encoding values and fusion displayed with the reconstructed vein. The vein and skin surface are both reconstructed in the 3D space. Results show that the structures can be precisely back-projected to the back of the hand for further augmented display and visualization. The overall system performance is evaluated in terms of vein segmentation, accuracy of vein matching, feature points distance error, duration times, accuracy of skin reconstruction, and augmented display. All experiments are validated with sets of real vein data. The imaging and augmented system produces good imaging and augmented reality results with high speed.

  18. Evaluation of outcome of corrective ulnar osteotomy with bone grafting and annular ligament reconstruction in neglected monteggia fracture dislocation in children.

    Science.gov (United States)

    Datta, Tanmay; Chatterjee, Nd; Pal, Ananda Kisor; Das, Sunil Kumar

    2014-06-01

    Neglected Monteggia fracture dislocation in the paediatric age group constitutes significant disability in respect to pain, stiffness, deformity, neurological compromise and restriction of activities of daily living. A longitudinal prospective study was done on 21 children with old Monteggia fracture-dislocation which included 18 cases of Bado type I and 3 cases of Bado type III at the department of orthopaedics, IPGME&R,SSKM hospital, Kolkata, India between 2007 and 2012. All were treated by modified Hirayama corrective osteotomy of ulna with wedge bone grafting along with restoration of its length and reconstruction of annular ligament using Bell Tawse method and fixation of radial head with transcapitellar Kirschner wire. Average follow up period was 5.5 years. Results were evaluated on the basis of 100 point Mayo Elbow Performance Index, radiology and questionnaire. The mean postoperative increase in Mayo Elbow Performance Index score was 30 with average increase in the range of movement by 30o. In three cases, there was subluxation of radial head and in addition one had transient palsy of posterior interosseous nerve. Three cases showed distortion of the radial head which were insignificant functionally. Results of improvement in mean MEPI were analysed by chi-square test and was significant at 0 .01 level of significance. Study showed good results with modified Hirayama osteotomy with annular ligament reconstruction using Bell Tawse procedure which is a more biological option for restoration of elbow biomechanics.

  19. Varicose vein - noninvasive treatment

    Science.gov (United States)

    ... spider veins. These are small varicose veins. Salt water (saline) or a chemical solution is injected into the varicose vein. The vein will harden and then disappear. Laser treatment can be used on the surface of the skin. Small bursts ...

  20. Varicose vein stripping

    Science.gov (United States)

    ... stripping; Venous reflux - vein stripping; Venous ulcer - veins Patient Instructions Surgical wound care - open Varicose veins - what to ask your doctor Images Circulatory system References American Family Physician. Management of varicose veins. www.aafp.org/afp/2008/ ...

  1. What Are Varicose Veins?

    Science.gov (United States)

    ... Leer en español What Is Varicose (VAR-i-kos) veins are swollen, twisted veins that you can ... TA-ze-uhs), spider veins, varicoceles (VAR-i-ko-seals), and other vein problems. Telangiectasias Telangiectasias are ...

  2. Proximal Pole Scaphoid Nonunion Reconstruction With 1,2 Intercompartmental Supraretinacular Artery Vascularized Graft and Compression Screw Fixation.

    Science.gov (United States)

    Morris, Mark S; Zhu, Andy F; Ozer, Kagan; Lawton, Jeffrey N

    2018-02-06

    To review the incidence of union of patients with proximal pole scaphoid fracture nonunions treated using a 1,2 intercompartmental supraretinacular artery (1,2 ICSRA) vascularized graft and a small compression screw. This is a retrospective case series of 12 patients. Calculations of the size of the proximal pole fragment relative to the total scaphoid were performed using posteroanterior view scaphoid radiographs with the wrist in ulnar deviation and flat on the cassette. Analyses were repeated 3 times per subject, and the average ratio of proximal pole fragment relative to the entire scaphoid was calculated. We reviewed medical records, radiographs, and computed tomography (CT) scans of these 12 patients. The CT scans that were performed after an average of 12 weeks were ultimately used to confirm union of the scaphoid fractures. One patient was unable to have a CT so was excluded from the final calculation. All 11 (100%) scaphoid fractures that were assessed by CT were found to be healed at the 12-week assessment point. The mean proximal pole fragment size was 18% (range, 7%-27%) of the entire scaphoid. The 1,2 ICSRA vascularized graft and compression screw was an effective treatment for patients with proximal pole scaphoid fractures. Therapeutic IV. Copyright © 2018 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  3. Immediate Reconstruction of Failed Implants in the Esthetic Zone Using a Flapless Technique and Autogenous Composite Tuberosity Graft

    NARCIS (Netherlands)

    Raghoebar, Gerry M; Meijer, Henny J A; van Minnen, Baucke; Vissink, Arjan

    We describe a technique for immediate reconstruction of bone after removal of failed dental implants in the esthetic region to optimize the esthetic outcome of retreatment. We conducted a study of 16 consecutive patients in whom the bony defect resulting from implant removal was immediately

  4. Factors that influence the intra-articular rupture pattern of the ACL graft following single-bundle reconstruction

    NARCIS (Netherlands)

    van Eck, Carola F.; Kropf, Eric J.; Romanowski, James R.; Lesniak, Bryson P.; Tranovich, Michael J.; van Dijk, C. Niek; Fu, Freddie H.

    2011-01-01

    The number of revision anterior cruciate ligament (ACL) surgeries performed annually continues to rise. The purpose of this study was to determine the most common rupture pattern in ACL revision cases after previous single-bundle reconstruction. The second aim was to determine the relationship

  5. Skin graft

    Science.gov (United States)

    Skin transplant; Skin autografting; FTSG; STSG; Split thickness skin graft; Full thickness skin graft ... donor site. Most people who are having a skin graft have a split-thickness skin graft. This takes ...

  6. Laparoscopic creation of neovagina and neocervix, followed by their reconstruction with polytetrafluoroethylene graft/buccal mucosa and pudendal artery perforator flap

    Directory of Open Access Journals (Sweden)

    Yi-Chieh Li

    2015-11-01

    Full Text Available Congenital cervical agenesis of is a rare Müllerian anomaly that may be associated with partial or complete vaginal aplasia and renal anomalies. Symptoms such as amenorrhea and abdominal pain usually develop shortly after menarche, when the absence or obstruction of the cervical canal results in blood accumulation in the uterus and fallopian tubes, and finally in the peritoneal cavity. Physical examination sometimes reveals normally developed external sex organs. Delayed diagnosis and treatment may potentially result in extensive endometriosis, which may potentially cause severe adhesion and damage to reproductivity. Such consequences could complicate further the management of the disease. Traditionally, hysterectomy has been the treatment of choice in these cases because of the high failure rate of canalization procedures and risk of serious ascending infection. With advanced laparoscopic techniques, conservative management seems feasible and has been recommended. We herein present a patient with complete cervical and vaginal agenesis. Creation of a neovagina and uterovaginal anastomosis were performed first under the guidance of laparoscopy (Figure 1. A neocervix was composed of a polytetrafluoroethylene graft and a piece of oral mucosa retrieved from the buccal area. The neovagina was reconstructed with an external pudendal artery perforator flap. A cervical Fr 16 size Foley was left in place as a stent. The patient had uneventful postoperative recovery and fair wound healing at the outpatient follow-up. Congenital agenesis of the uterine cervix and vagina can be differentiated accurately and reconstructed laparoscopically. Using mesh-buccal mucosa composite and pudendal perforator flap is a practical way to reconstruct neocervix and neovagina after their creation.

  7. Use of a strontium-enriched calcium phosphate cement in accelerating the healing of soft-tissue tendon graft within the bone tunnel in a rabbit model of anterior cruciate ligament reconstruction.

    Science.gov (United States)

    Kuang, G M; Yau, W P; Lu, W W; Chiu, K Y

    2013-07-01

    We investigated whether strontium-enriched calcium phosphate cement (Sr-CPC)-treated soft-tissue tendon graft results in accelerated healing within the bone tunnel in reconstruction of the anterior cruciate ligament (ACL). A total of 30 single-bundle ACL reconstructions using tendo Achillis allograft were performed in 15 rabbits. The graft on the tested limb was treated with Sr-CPC, whereas that on the contralateral limb was untreated and served as a control. At timepoints three, six, nine, 12 and 24 weeks after surgery, three animals were killed for histological examination. At six weeks, the graft-bone interface in the control group was filled in with fibrovascular tissue. However, the gap in the Sr-CPC group had already been completely filled in with new bone, and there was evidence of the early formation of Sharpey fibres. At 24 weeks, remodelling into a normal ACL-bone-like insertion was found in the Sr-CPC group. Coating of Sr-CPC on soft tissue tendon allograft leads to accelerated graft healing within the bone tunnel in a rabbit model of ACL reconstruction using Achilles tendon allograft.

  8. Hypothenar hammer syndrome: long-term results of vascular reconstruction.

    Science.gov (United States)

    Endress, Ryan D; Johnson, Craig H; Bishop, Allen T; Shin, Alexander Y

    2015-04-01

    To evaluate long-term patency rates and related outcomes after vascular reconstruction of hypothenar hammer syndrome and identify patient- or treatment-related factors that may contribute to differences in outcome. We used color flow ultrasound to determine the patency of 18 vein graft reconstructions of the ulnar artery at the wrist in 16 patients. Validated questionnaires evaluated patients' functional disability with the Disabilities of the Arm, Shoulder, and Hand score, pain with the visual analog scale, and cold intolerance with the Cold Intolerance Symptom Severity survey. Patient demographics, clinical data, and surgical factors were analyzed for association with graft failure. Patients were asked to grade the result of treatment on a scale of 0 to 10. Of 18 grafts, 14 (78%) were occluded at a mean of 118 months postoperatively. Patients with patent grafts had significantly less disability related to cold intolerance according to the Cold Intolerance Symptom Severity survey in addition to significantly less pain on the visual analog scale. There was no statistical difference in Disabilities of the Arm, Shoulder, and Hand scores between patients with patent or occluded grafts. Patients graded the result significantly higher in patent reconstructions. We noted a higher incidence of graft occlusion than previously reported at a mean follow-up of 9.8 years, which represents a long-duration follow-up study of surgical treatment of hypothenar hammer syndrome. Despite a high percentage of occlusion, overall, patients remained satisfied with low functional disability and all would recommend surgical reconstruction. This study suggests that improved outcomes may result from patent grafts in the long term. Prognostic IV. Copyright © 2015 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  9. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Science.gov (United States)

    Lamana, Fernando de Azevedo; Dias, Ricardo Ribeiro; Duncan, Jose Augusto; Faria, Leandro Batisti de; Malbouisson, Luiz Marcelo Sa; Borges, Luciano de Figueiredo; Mady, Charles; Jatene, Fábio Biscegli

    2015-01-01

    To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graft-valve replacement. From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling). Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%), with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation. In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001) and lower bleeding complications (P=0.006). There was no difference for thromboembolism, endocarditis, and need of reoperation. The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  10. Broken Bioabsorbable Tibial Interference Screw after Anterior Cruciate Ligament (ACL Reconstruction using a Semitendinosus-gracilis Graft: A Case Report

    Directory of Open Access Journals (Sweden)

    Huang ME Deborah

    2012-07-01

    Full Text Available When a patient presents with knee pain and locking after an anterior cruciate ligament (ACL reconstruction, a new meniscal injury or an osteochondral loose body are usually considered for differential diagnosis. We present the case of a 22-year-old female with just these complaints 6 months after ACL reconstruction surgery. Magnetic resonance imaging (MRI of the knee showed a broken screw tip which was later arthroscopically removed. At arthroscopy, an 11mm long broken bioabsorbable interference screw tip was found lying in the intercondylar notch; this resulted in a 0.5cm Outerbridge grade II chondral ulcer located at mid- patella. Both menisci and cruciate ligaments were intact and no other loose bodies were found in the knee joint.

  11. Evaluation of temporal windows for coronary artery bypass graft imaging with 64-slice CT

    International Nuclear Information System (INIS)

    Desbiolles, Lotus; Leschka, Sebastian; Scheffel, Hans; Husmann, Lars; Garzoli, Elisabeth; Marincek, Borut; Alkadhi, Hatem; Plass, Andre; Gaemperli, Oliver; Kaufmann, Philipp A.

    2007-01-01

    Temporal windows providing the best image quality of different segments and types of coronary artery bypass grafts (CABGs) with 64-slice computed tomography (CT) were evaluated in an experimental set-up. Sixty-four-slice CT with a rotation time of 330 ms was performed in 25 patients (four female; mean age 59.9 years). A total of 84 CABGs (62 individual and 22 sequential grafts) were evaluated, including 28 internal mammary artery (33.3%), one radial artery with sequential grafting (2.4%), and 54 saphenous vein grafts (64.3%). Ten data sets were reconstructed in 10% increments of the RR-interval. Each graft was separated into segments (proximal and distal anastomosis, and body), and CABG types were grouped according to target arteries. Two readers independently assessed image quality of each CABG segment in each temporal window. Diagnostic image quality was found with good inter-observer agreement (kappa=0.62) in 98.5% (202/205) of all graft segments. Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001) and for distal anastomosis to the right coronary compared with other target coronary arteries (P<0.05). Overall, best image quality was found at 60%. Image quality of proximal segments did not significantly vary with the temporal window, whereas for all other segments image quality was significantly better at 60% compared with other temporal windows (P<0.05). Sixty-four-slice CT provides best image quality of various segments and types of CABG at 60% of the RR-interval. (orig.)

  12. One-stage reconstruction of soft tissue defects with the sandwich technique: Collagen-elastin dermal template and skin grafts

    Directory of Open Access Journals (Sweden)

    Uwe Wollina

    2011-01-01

    Full Text Available Background : A full-thickness soft tissue defect closure often needs complex procedures. The use of dermal templates can be helpful in improving the outcome. Objective : The objective was to evaluate a sandwich technique combining the dermal collagen-elastin matrix with skin grafts in a one-stage procedure. Materials and Methods : Twenty-three patients with 27 wounds were enrolled in this prospective single-centre observational study. The mean age was 74.8 ± 17.2 years. Included were full-thickness defects with exposed bone, cartilage and/ or tendons. The dermal collagen-elastin matrix was applied onto the wound bed accomplished by skin transplants, i.e. ′sandwich′ transplantation. In six wounds, the transplants were treated with intermittent negative pressure therapy. Results : The size of defects was ≤875 cm 2 . The use of the dermal template resulted in a complete and stable granulation in 100% of wounds. Seventeen defects showed a complete closure and 19 achieved a complete granulation with an incomplete closure. There was a marked pain relief. No adverse events were noted due to the dermal template usage. Conclusions : Sandwich transplantation with the collagen-elastin matrix is a useful tool when dealing with full-thickness soft tissue defects with exposed bone, cartilage or tendons.

  13. The Short Saphenous Vein: A Viable Alternative Conduit for ...

    African Journals Online (AJOL)

    This novel position allowed for two members of the surgical team to operate at the same time, thus ... along the ultrasound-marked vein positions similar to when harvesting the LSV. Once the veins were harvested and ... occlusion compared to LSV grafts utilized in the same procedure,[8] it was brought back to prominence ...

  14. Perforator based rectus free tissue transfer for head and neck reconstruction: New reconstructive advantages from an old friend.

    Science.gov (United States)

    Kang, Stephen Y; Spector, Matthew E; Chepeha, Douglas B

    2017-11-01

    To demonstrate three reconstructive advantages of the perforator based rectus free tissue transfer: long pedicle, customizable adipose tissue, and volume reconstruction without muscle atrophy within a contained space. Thirty patients with defects of the head and neck were reconstructed with the perforator based rectus free tissue transfer. Transplant success was 93%. Mean pedicle length was 13.4cm. Eleven patients (37%) had vessel-poor necks and the long pedicle provided by this transplant avoided the need for vein grafts in these patients. Adipose tissue was molded in 17 patients (57%). Twenty-five patients (83%) had defects within a contained space, such as the orbit, where it was critical to have a transplant that avoided muscle atrophy. The perforator based rectus free tissue transfer provides a long pedicle, moldable fat for flap customization, and is useful in reconstruction of defects within a contained space where volume loss due to muscle atrophy is prevented. Copyright © 2017 Elsevier Ltd. All rights reserved.

  15. Results of Use of Tissue-Engineered Autologous Oral Mucosa Graft for Urethral Reconstruction: A Multicenter, Prospective, Observational Trial.

    Science.gov (United States)

    Ram-Liebig, Gouya; Barbagli, Guido; Heidenreich, Axel; Fahlenkamp, Dirk; Romano, Giuseppe; Rebmann, Udo; Standhaft, Diana; van Ahlen, Hermann; Schakaki, Samer; Balsmeyer, Ulf; Spiegler, Maria; Knispel, Helmut

    2017-09-01

    Harvest of oral mucosa for urethroplasty due to urethral stricture is associated with donor-site-morbidity. We assessed functionality and safety of an authorized tissue-engineered oral mucosa graft (TEOMG) under routine practice in stricture recurrences of any etiology, location, length and severity (real-world data). 99 patients from eight centers with heterogenous urethroplasty experience levels were included in this prospective, non-interventional observational study. Primary and secondary outcomes were success rate (SR) and safety at 12 and 24months. All but one patient had ≥1, 77.1% (64 of 83)≥2 and 31.3% (26 of 83)≥4 previous surgical treatments. Pre- and postoperative mean±SD peak flow rate (Qmax) were 8.3±4.7mL/s (n=57) and 25.4±14.7mL/s (n=51). SR was 67.3% (95% CI 57.6-77.0) at 12 and 58.2% (95% CI 47.7-68.7) at 24months (conservative Kaplan Meier assessment). SR ranged between 85.7% and 0% in case of high and low surgical experience. Simple proportions of 12-month and 24-month SR for evaluable patients in all centers were 70.8% (46 of 65) and 76.9% (30 of 39). Except for one patient, no oral adverse event was reported. TEOMG is safe and efficient in urethroplasty. Copyright © 2017 The Authors. Published by Elsevier B.V. All rights reserved.

  16. Change in reimbursement and costs in German oncological head and neck surgery over the last decade: ablative tongue cancer surgery and reconstruction with split-thickness skin graft vs. microvascular radial forearm flap.

    Science.gov (United States)

    Hoefert, Sebastian; Lotter, Oliver

    2018-05-01

    Defects after ablative tongue cancer surgery can be reconstructed by split-thickness skin grafts or free microvascular flaps. The different surgical options may influence costs, reimbursement, and therefore possible profits. Our goal was to analyze the development of these parameters for different procedures in head and neck reconstruction in Germany over the last decade. After tumor resection and neck dissection of tongue cancer, three different scenarios were chosen to calculate costs, reimbursement, length of stay (LoS), and profits. Two options considered were reconstruction by split-thickness skin graft with (option Ia) and without (option Ib) tracheotomy. In addition, we analyzed microvascular reconstruction with radial forearm flap (option II). Furthermore, unsatisfactory results after options Ia and Ib may make secondary tongue plastic with split-thickness skin grafting necessary (option I+). The calculations were performed considering the German Diagnosis Related Group (DRG) system and compared to the specific DRG cost data of 250 German reference hospitals. The overall average length of stay (aLoS) declined from 16.7 to 12.8 days with a reduction in every option. Until 2011, all options showed similar accumulated DRG reimbursement. From 2012 onwards, earnings almost doubled for option II due to changes in the DRG allocation. As was expected, the highest costs were observed in option II. Profits (reimbursement minus costs) were also highest for option II (mean 2052 €, maximum 3630 Euros in 2015) followed by options Ia (765 €) and Ib/I+ (681 €). Average profits over time would be 17 to 19% higher if adjusted for inflation. We showed the development of the DRG allocation of two commonly used methods of reconstruction after ablative tongue cancer surgery and the associated LoS, reimbursement, costs, and profits. As expected, the highest values were found for microvascular reconstruction. Microvascular reconstruction may also be the primary choice of

  17. Intraosseous focal venous malformation of the mandibular body: Cone beam computed tomography planning followed by piezoelectric knife resection and free bone graft reconstruction

    Directory of Open Access Journals (Sweden)

    Nikolić Živorad S.

    2017-01-01

    Full Text Available Introduction. Intraosseous vascular malformation could be life-threatening due to uncontrolled hemorrhage after tooth extraction. According to biological behavior of this lesion, adequate diagnostic and treatment strategies are necessary in order to avoid possible complications. We reported cone beam computed tomography (CBCT planning of an urgent en bloc resection of an intraosseous venous malformation by piezoelectric knife. Case report. A 55-year-old man was submitted to CBCT planning followed by piezoelectric knife resection of an intraosseous focal venous malformation of the mandibular body. Immediate reconstruction of the defect using iliac bone free graft was performed. The surgical treatment was uneventful and a 2-year follow-up revealed no signs of recurrence. Conclusion. Piezoelectric knife could provide precise, safe and bloodless procedure which is especially important in this pathology. Advantages of this technique are: lower risk of damaging soft tissue structures, precise osteotomy and bloodless surgery. Moreover, using piezosurgery bone knife, blood transfusion and blood transmitted diseases could be avoided. This case highlights the importance of CBCT as planning tool for resection of the mandible, using piezoelectric knife as safe method to achieve bloodless surgery. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 175075

  18. Locking plate and fibular strut-graft augmentation in the reconstruction of unicameral bone cyst of proximal femur in the paediatric population.

    Science.gov (United States)

    Jamshidi, Khodamorad; Mirkazemi, Masoud; Izanloo, Azra; Mirzaei, Alireza

    2018-01-01

    Several therapeutic strategies have been used for managing unicameral bone cyst (UBC) of the proximal femur. However, there is insufficient evidence to support one treatment over another, and the optimal treatment is controversial. This study aims at describing our experience with surgical reconstruction of paediatric UBCs of the proximal femur using a proximal locking plate and fibular strut allograft. In total, 14 consecutive paediatric patients with Dormans types IB (four cases) and IIB (10 cases) UBC were assessed. Mean patient age was 8.6 ± 2.3 years, and mean follow-up period was 41.7 ± 29.8 months. Six patients (42.8%) were referred with a pathologic fracture. Clinical/radiological outcome and complication rates were evaluated at the final follow-up session. No cysts were Capanna's class III (recurrence) or IV (no response). Complete healing (Capanna's class I) was seen in ten cysts, while four other cysts healed with residual radiolucent areas (Capanna's class II). Mean healing period was 14.1 ± 5.1 (9-24 months). One patient had superficial infection, one heterotopic ossification, and one mild coxa vara, and mean Musculoskeletal Tumor Society (MSTS) score was 99.5%. According to our results, locking plate and fibular strut graft in Dormans classification types IB and IIB results in a favorable outcome in managing UBC of the proximal femur in the paediatric population.

  19. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Directory of Open Access Journals (Sweden)

    Fernando de Azevedo Lamana

    2015-09-01

    Full Text Available AbstractObjective:To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graftvalve replacement.Methods:From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling. Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%, with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation.Results:In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001 and lower bleeding complications (P=0.006. There was no difference for thromboembolism, endocarditis, and need of reoperation.Conclusion:The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  20. Focus on Varicose Veins

    Science.gov (United States)

    ... because the valves of the veins no longer work. Under the pressure of gravity these veins can continue to expand and, in ... and to determine whether the vein valves are work- ing properly or have ... painless. How are varicose veins treated? Varicose veins are always ...

  1. Varicose Veins - Multiple Languages

    Science.gov (United States)

    ... Concerns and Discomforts of Pregnancy: Varicose Veins - English MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - 简体中文 (Chinese, Simplified (Mandarin dialect)) MP3 Concerns and Discomforts of Pregnancy: Varicose Veins - English ...

  2. Spider Vein Removal

    Science.gov (United States)

    Spider veins: How are they removed? I have spider veins on my legs. What options are available ... M.D. Several options are available to remove spider veins — thin red lines or weblike networks of ...

  3. Over-the-top ACL Reconstruction Plus Extra-articular Lateral Tenodesis With Hamstring Tendon Grafts: Prospective Evaluation With 20-Year Minimum Follow-up.

    Science.gov (United States)

    Zaffagnini, Stefano; Marcheggiani Muccioli, Giulio Maria; Grassi, Alberto; Roberti di Sarsina, Tommaso; Raggi, Federico; Signorelli, Cecilia; Urrizola, Francisco; Spinnato, Paolo; Rimondi, Eugenio; Marcacci, Maurilio

    2017-12-01

    There are few published studies with very long-term follow-up of combined intra- and extra-articular anterior cruciate ligament (ACL) reconstruction. To analyze clinical and radiographic outcomes of over-the-top ACL reconstruction plus extra-articular lateral tenodesis with autologous hamstrings at minimum 20-year follow-up. Case series; Level of evidence, 4. Of 60 originally eligible patients who underwent over-the-top ACL reconstruction with double-stranded hamstring tendon (leaving intact graft tibial insertions) and extra-articular lateral plasty (performed with the remnant part of tendons), 52 were prospectively evaluated at a minimum 20-year follow-up (mean follow-up, 24 years; 41 men, 11 women; mean age at time of surgery, 25.5 ± 7.6 years). Twenty-nine patients were available for prospective evaluations: clinical (Lysholm, Tegner, and objective International Knee Documentation Committee [IKDC]), instrumented (KT-2000), and radiographic (standard, long-standing, and Merchant views). Subjective KOOS (Knee injury and Osteoarthritis Outcome Score) and objective inertial sensor pivot-shift analysis (KiRA) were carried out at final follow-up. Twenty-three patients were investigated by phone interview for subjective Tegner score and documented complications, rerupture, or revision surgery. At final follow-up, mean Lysholm score was 85.7 ± 14.6; median Tegner score, 4 (range, 3-5); sport activity resumption, 86.2%; and objective IKDC score, good or excellent in 86% of patients (31%, A; 55%, B). Only 3 of 26 patients (12%) had >5-mm manual maximum KT-2000 side-to-side difference. KiRA system documented positive pivot-shift (>0.9-m/s 2 tibial acceleration side-to-side difference) in these 3 of 26 patients (12%). Statistically significant changes were as follows: decrease in Tegner score from 7 (range, 6-8) at 5-year follow-up to 4 (range, 3-5) at 10 years ( P < .0001) and decrease in Lysholm score from 96.1 ± 7.3 at 10-year follow-up to 85.7 ± 14.6 at 20 years

  4. Transurethral ventral buccal mucosa graft inlay urethroplasty for reconstruction of fossa navicularis and distal urethral strictures: surgical technique and preliminary results.

    Science.gov (United States)

    Nikolavsky, Dmitriy; Abouelleil, Mourad; Daneshvar, Michael

    2016-11-01

    To introduce a novel surgical technique for the reconstruction of distal urethral strictures using buccal mucosal graft (BMG) through a transurethral approach. A retrospective institution chart review was conducted of all the patients who underwent a transurethral ventral BMG inlay urethroplasty from March 2014 to March 2016. Patients with greater than one-year follow-up were included. Steps of the procedure: transurethral ventral wedge resection of the stenosed segment and transurethral delivery and spread fixation of appropriate BMG inlay into the resultant urethrotomy. The patients were followed for post-operative complications and stricture recurrence with uroflow, PVR, cystoscopy and outcome questionnaires. Three patients with a minimum of 12-month follow-up are included in this case series. The mean age of the patients was 42 years (35-53); mean stricture length was 2.1 cm (1-4). All patients had at least 2 previous failed procedures. Mean follow-up was 18 months (12-24). There were no stricture recurrences or fistula. Mean pre- and post-operative uroflow values were 4.3 (0-8) and 19 (16-26), respectively. Neither penile chordee nor changes in sexual function were noted in patients on follow-up. Transurethral ventral BMG inlay urethroplasty is a feasible option for treatment of fossa navicularis strictures. This single-stage technique allows for avoiding skin incision or urethral mobilization. It helps to prevent glans dehiscence, fistula formation and avoids the use of genital skin flaps in all patients, especially those affected with LS. This novel surgical technique is an effective treatment alternative for men with distal urethral strictures.

  5. Sequential MRI Study of Graft Integrity and Signal Following Pediatric All-epiphyseal ACL Reconstruction: Does the “Sharp Turn” at the Socket of the Distal Femoral Aperture Matter?

    Science.gov (United States)

    Tuca, Maria; Greditzer, Harry Gus; Gausden, Elizabeth Bishop; Uppstrom, Tyler J.; Potter, Hollis G.; Cordasco, Frank A.; Green, Daniel W.

    2017-01-01

    Objectives: To analyze graft structure and signal with particular emphasis on the distal femoral socket aperture following all-epiphyseal ACLR using hamstring autografts with sequential MRI in skeletally immature athletes. Methods: Retrospective cohort study of 23 skeletally immature patients who underwent ACLR by the same surgical team at a tertiary center during 2011-2013. Athletes had at least two follow-up MRIs, the first MRI 6-12 months after surgery and the second MRI >18 months, were included. Exclusion criteria included those athletes with inMRI follow-up (6) or with a failure of their reconstructions (1). All athletes were treated with an arthroscopic all-inside, all-epiphyseal ACLR, using hamstring autograft, secured with adjustable loop cortical buttons on both tibia and femur. MRI images were analyzed independently and blinded by an orthopaedic surgery fellow and a musculoskeletal radiology fellow. Using a GE Functional Analysis Software, the signal intensity (SI) of the graft was measured in 5 different locations: 1) femoral tunnel, 2) intra-articular proximal turn, 3) midsubstance, 4) intra-articular distal turn, and 5) tibial tunnel. Values were normalized to cortical bone density. The amount of perigraft scarring and synovitis was analyzed. An intraclass correlation coefficient was used to quantify inter-rater reliability, non-parametric Wilcoxon test for perigraft scarring and synovitis, one-way ANOVA to test if significant differences of SI were seen between the different graft locations, and a 2-tailed student t-test for SI changes from 1st to 2nd MRI. Results: The study included 16 patients (5 girls and 11 boys), with an average age at surgery of 11.9 years (range 10-15). The first follow-up MRI was on average at 8.4 months (range 6-12 months), while the 2nd MRI was on average 30.7 months (range 18-40) after surgery. Intra-class correlation coefficients were above 0.7 for all measurements, indicating an excellent concordance between observers

  6. On free jejunal and colon transfer for pharyngo-esophageal reconstruction

    International Nuclear Information System (INIS)

    Fukui, Kiyoko; Annraku, Kuniaki; Ikenoya, Shintaro; Makino, Sachio; Ito, Kazuyuki; Takubo, Kenji; Kaji, Shogo

    2013-01-01

    Free jejunal transfer is a common procedure for hypopharyngo-esophageal reconstruction. We reviewed our experience with patients who underwent free jejunal and colon transfer surgery for hypopharyngo-esophageal reconstruction in the last 20 years in our institute. A retrospective review was conducted for 31 cases of reconstruction with free jejunal and colon transfer performed at Japanese Red Cross Matsue Hospital during the period of 20 years from January 1992 to December 2011. The mean age of the patients was 66 years. There were 30 patients with hypopharynx cancer and one patient with larynx cancer. Thirty patients had received preoperative radiotherapy and chemotherapy. The average time of surgery for free jejunal transfer reconstruction was 8.8 hours, including extraction of the hypopharynx, pharynx and cervical esophagus, debridment of pars hemi-cervicalis, and grafting procedure of free jejunum. The most common recipient vessels were the transverse cervical artery and external jugular vein, but recently, vessels of free flaps are often chosen to be anastomosed with the superior thyroid artery and internal jugular vein. The free jejunal and colon grafts for reconstruction took successfully in all patients. The complication rate was 52% (16/31 cases). Complications often occurred in cases of total esophagectomy, recurrence after full-dose chemoradiotherapy, and radiation therapy administered postoperatively. (author)

  7. Fatores de risco que afetam as complicações da dissecação da veia safena na revascularização cirúrgica do miocárdio The risk factors affecting the complications of saphenous vein graft harvesting in aortocoronary bypass surgery

    Directory of Open Access Journals (Sweden)

    Monir Abbaszadeh

    2008-09-01

    Full Text Available OBJETIVO: O problema da cicatrização de feridas é comumente observado após procedimentos de revascularização do miocárdio. Nosso objetivo é determinar a prevalência e os indicadores de complicação na dissecação da veia safena após procedimentos de revascularização coronária. MÉTODOS: Após revisão e aprovação pelo comitê de ética da instituição, uma revisão retrospectiva de 4029 procedimentos de revascularização foi realizada com enxerto da veia safena durante um período de seis anos. Treze fatores de risco para aqueles que desenvolveram complicações extensas nas feridas da perna foram analisados e comparados com toda a coorte de pacientes submetidos a procedimentos de revascularização semelhantes durante o mesmo período. RESULTADOS: Complicações nas feridas do membro inferior ocorreram em 68 pacientes (1,7%, 43 deles precisaram de intervenção cirúrgica adicional. Foram realizados 17 desbridamentos de feridas, nove transplantes de pele, uma angioplastia, 11 fasciotomias, três procedimentos vasculares e duas transferências livre de tecidos. Das treze variáveis analisadas pela análise multivariada, sexo feminino, IMC, uso de enxerto de veia torácica interna, doença vascular periférica, o uso de balão intra-aórtico no pós-operatório e hiperlipidemia pré-existente foram identificados como indicadores independentes significativos de complicações extensas nas feridas a perna (pOBJECTIVE: Problem of wound healing is commonly observed after coronary artery bypass graft procedures. Our aim is to determine the prevalence and the predictors of saphenous vein harvesting complication after coronary revascularization procedures. METHODS: After institutional ethical committee review and approval, a retrospective review was undertaken of 4029 bypass procedures with saphenous vein graft performed over a period of six years is conducted. Thirteen risk factors for those who developed major leg wound

  8. Portal Vein Thrombosis

    Directory of Open Access Journals (Sweden)

    Hakan Demirci

    2016-01-01

    Full Text Available Portal vein thrombosis is an important cause of presinusoidal portal hypertension. Portal vein thrombosis commonly occurs in patient with cirrhosis, malignancy and prothrombotic states. Patients with acute portal vein thrombosis have immediate onset. Patients with chronic portal vein thrombosis have developed portal hypertension and cavernous portal transformation. Portal vein thrombosis is diagnosed with doppler ultrasound, computed tomography and magnetic resonance imaging. Therapy with low molecular weight heparin achieves recanalization in more than half of acute cases.

  9. [Portal perfusion with right gastroepiploic vein flow in liver transplant].

    Science.gov (United States)

    Mendoza-Sánchez, Federico; Javier-Haro, Francisco; Mendoza-Medina, Diego Federico; González-Ojeda, Alejandro; Cortés-Lares, José Antonio; Fuentes-Orozco, Clotilde

    Liver transplantation in patients with liver cirrhosis, portal vein thrombosis, and cavernous transformation of the portal vein, is a complex procedure with high possibility of liver graft dysfunction. It is performed in 2-19% of all liver transplants, and has a significantly high mortality rate in the post-operative period. Other procedures to maintain portal perfusion have been described, however there are no reports of liver graft perfusion using right gastroepiploic vein. A 20 year-old female diagnosed with cryptogenic cirrhosis, with a Child-Pugh score of 7 points (class "B"), and MELD score of 14 points, with thrombosis and cavernous transformation of the portal vein, severe portal hypertension, splenomegaly, a history of upper gastrointestinal bleeding due to oesophageal varices, and left renal agenesis. The preoperative evaluation for liver transplantation was completed, and the right gastroepiploic vein of 1-cm diameter was observed draining to the infrahepatic inferior vena cava and right suprarenal vein. An orthotopic liver transplantation was performed from a non-living donor (deceased on January 30, 2005) using the Piggy-Back technique. Portal vein perfusion was maintained using the right gastroepiploic vein, and the outcome was satisfactory. The patient was discharged 13 days after surgery. Liver transplantation was performed satisfactorily, obtaining an acceptable outcome. In this case, the portal perfusion had adequate blood flow through the right gastroepiploic vein. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  10. Injertos óseos: Una alternativa efectiva y actual para la reconstrucción del complejo cráneo-facial BONE GRAFTS: AN EFFECTIVE AND CURRENT ALTERNATIVE FOR THE RECONSTRUCTION OF THE CRANIOFACIAL COMPLEX

    Directory of Open Access Journals (Sweden)

    Sergio Soto Góngora

    2005-04-01

    Full Text Available El empleo de injertos óseos como alternativa de reconstrucción de defectos óseos, ya sean congénitos u ocasionados como traumatismos, secuelas oncológicas e infecciosas, tienen como finalidad restablecer la integridad anatómica y funcional de una estructura alterada. Durante décadas, los investigadores se han dado a la tarea de encontrar en los injertos ciertas características que respondan a cada una de las necesidades de reconstrucción; este hecho a llevado a estudiar y comparar los beneficios de algunas estructuras óseas potencialmente donadoras, que incrementen las probabilidades de éxito del tratamiento y disminuyan considerablemente los posibles riesgos y complicaciones durante la toma del injerto. De igual manera, se han estudiado diversos materiales implantológicos, sin embargo, estos no poseen la capacidad natural de inducir el proceso de regeneración ósea, haciendo de ellos materiales inertes biocompatibles de "relleno", que no sustituyen las características de los injertos, pero utilizados conjuntamente si así se requiere, pueden mejorar los resultados. El presente trabajo plantea la utilización de injertos óseos como una alternativa viable, efectiva y actual en materia de reconstrucción.The use of bone grafts as an alternative to reconstruct osteal congenital or caused defects, such as traumatisms, oncological and infectious sequelae, is aimed at restoring the anatomical and functional integrity of an altered structure. During decades, investigators have tried to find in grafts certain characteristics that response to each of the reconstruction needs. This fact has led to the study and comparison of the benefits of some osteal structures that are potential donors and may increase the chances of success and considerably reduce the possible risks and complications during the graft taking. Likewise, diverse implantation materials have been studied, but they do not have the natural capacity to induce the osteal

  11. Platlet Rich Plasma (PRP) Improves Fat Grafting Outcomes.

    Science.gov (United States)

    Modarressi, Ali

    2013-01-01

    Autologous fat transfer offers many qualities of a ideal soft tissue filler. Main advantages of fat grafting ensue from the fact that the lipoaspirate tissue is an abundant source of regenerative pluripotential cells. However, the reported rates of fat cell survival vary greatly in the medical literature (10-90%). Different techniques of harvesting, processing, and reinjecting the fat cells are so claimed to be responsible for these differences, without any agreement concerning the best way to process. To address this important disadvantage, we propose the addition of autologous platelet rich plasma (PRP) which is known as a natural reservoir of growth factors stimulating tissue repair and regeneration. This approach is completely autologous and immediately employed without any type of preconditioning. Platelets rich plasma (PRP) preparation included bleeding of 8 ml of blood from patient's peripheral vein in Regen Lab© tubes containing sodium citrate anticoagulant. The whole blood was centrifugated at 1500 g during 3 min. As Regen-tubes contained a special gel separator, 99 % of red blood cells were discarded from the plasma at the bottom of the gel, and >90% of platelets were harvested in 4 ml of plasma on the top of the gel, called the platelet-rich plasma (PRP). The purified fat prepared by Coleman technique was mixed with different amount of PRP for in vitro, in vivo (mice) and clinical experiments: >50% of PRP for skin rejuvenation, superficial scars correction, infraorbital region, ..., and for 20% of PRP with 80% of purified fat for deep filler indication (nasolabial folds, lips, or soft tissue defect). In vitro studies demonstrated that PRP increased fat cells survival rate and stem cells differentiation. Animal models showed that fat graft survival rate was significantly increased by addition of PRP. Several clinical cases confirmed the improvement of wound healing and fat grafting survival in facial reconstruction and aesthetic cases by association of

  12. ACL Graft Healing and Biologics

    NARCIS (Netherlands)

    Muller, Bart; Bowman, Karl F.; Bedi, Asheesh

    2013-01-01

    Operative reconstruction of a torn anterior cruciate ligament (ACL) has become the most broadly accepted treatment. An important, but underreported, outcome of ACL reconstruction is graft failure, which poses a challenge for the orthopedic surgeon. An understanding of the tendon-bone healing and the

  13. Evaluation of a xenogeneic acellular collagen matrix as a small-diameter vascular graft in dogs--preliminary observations.

    Science.gov (United States)

    Nemcova, S; Noel, A A; Jost, C J; Gloviczki, P; Miller, V M; Brockbank, K G

    2001-01-01

    Autogenous veins are the materials of choice for arterial reconstruction. In the absence of autogenous material, prosthetic materials are used. However, vascular prostheses of less than 0.4 cm in diameter have low long-term patency. This study was designed to determine if cells would infiltrate an engineered xenogeneic biomaterial used as a small diameter arterial graft in dogs and, if so, to determine the phenotype of the infiltrating cells. Nine acellular xenogeneic grafts (0.4 cm in diameter, 5 cm long), composed of porcine collagen derived from the submucosa of the small intestine and type I bovine collagen, were implanted as end to-end interposition grafts in femoral arteries of five male mongrel dogs (total of nine grafts). All dogs received daily aspirin (325 mg). Patency of implanted grafts was monitored weekly by Duplex ultrasonography. After 9 weeks, or earlier in case of blood flow reduction by at least 75%, grafts were explanted and prepared for light or electron microscopy to evaluate cellularization. Eight of nine grafts remained patent up to 9 weeks. At explant, diameters were 0.31 +/- 0.02 cm at the midgraft, and 0.14 +/- 0.01 and 0.19 +/- 0.01 cm at the proximal and distal anastomoses. At explant, cells of mesenchymal origin (endothelial cells, smooth muscle cells, myofibroblasts) were embedded in the extracellular matrix of the graft scaffold. Minimal evidence of cellular inflammatory reaction and no aneurysmal dilatation or thrombus formation was detected. Variable degrees of hyperplasia were present at proximal and distal anastomoses. This preliminary study demonstrates that a collagen-based xenogeneic biomaterial provides a scaffold for cellularization when used for arterial reconstruction in dogs.

  14. Enrichment of autologous fat grafts with ex-vivo expanded adipose tissue-derived stem cells for graft survival

    DEFF Research Database (Denmark)

    Kølle, Stig-Frederik Trojahn; Fischer-Nielsen, Anne; Mathiasen, Anders Bruun

    2013-01-01

    Autologous fat grafting is increasingly used in reconstructive surgery. However, resorption rates ranging from 25% to 80% have been reported. Therefore, methods to increase graft viability are needed. Here, we report the results of a triple-blind, placebo-controlled trial to compare the survival ...... of fat grafts enriched with autologous adipose-derived stem cells (ASCs) versus non-enriched fat grafts....

  15. Reconstruction of the midface and maxilla.

    Science.gov (United States)

    Dalgorf, Dustin; Higgins, Kevin

    2008-08-01

    To review the current classification systems and reconstructive options available for restoration of maxillectomy defects. Defects involving the midface can have a great functional and aesthetic impact on the patient. Adequate restoration of the complex three-dimensional maxillary structure is required to replace form and function of the native tissue. An in-depth discussion of appropriate recipient vessel selection and reconstructive options are included in this article. The superficial temporal vessel system is presented as a reliable anastomosis site for restoration of midfacial defects. In addition, the complications of vein grafting, arteriovenous fistula loops and alternative recipient vessels sites are addressed to manage the challenge of the vessel-depleted neck. The current indications, advantages and disadvantages of local, regional and free-flap reconstructive options available for maxillectomy defects are highlighted in order to aid the surgeon in appropriate flap selection. A myriad of reconstructive options are available to restore maxillectomy defects. The surgeon must consider each defect and the needs of the individual patient when choosing the best suited reconstructive technique.

  16. Outcomes of AV Fistulas and AV Grafts after Interventional Stent-Graft Deployment in Haemodialysis Patients

    Energy Technology Data Exchange (ETDEWEB)

    Schmelter, Christopher, E-mail: christopher.schmelter@klinikum-ingolstadt.de; Raab, Udo, E-mail: udo.raab@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany); Lazarus, Friedrich, E-mail: friedrich.lazarus@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Nephrology (Germany); Ruppert, Volker, E-mail: volker.ruppert@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Vascular Surgery (Germany); Vorwerk, Dierk, E-mail: dierk.vorwerk@klinikum-ingolstadt.de [Klinikum Ingolstadt, Department of Diagnostic and Interventional Radiology (Germany)

    2015-08-15

    PurposeThe study was designed to assess outcomes of arteriovenous (AV) accesses after interventional stent-graft deployment in haemodialysis patients.Materials and Methods63 haemodialysis patients with 66 AV fistulas and AV grafts were treated by interventional stent-graft deployment from 2006 to 2012 at our hospital. Data of these patients were retrospectively analysed for location of deployed stent-grafts, occurrence and location of (re-)stenosis and (re-)thrombosis. Complex stenosis was the most frequent indication for stent-graft deployment (45.5 %), followed by complications of angioplasty with vessel rupture or dissection (31.8 %).ResultsA high rate of procedural success was achieved (98.5 %). The most frequent location of the deployed stent-graft was the draining vein (66.7 %). Stent-graft deployment was more frequent in AV grafts than in AV fistulas. Primary patency was 45.5 % at 6 month, 31.3 % at 12 month and 19.2 % at 24 month. Primary patency was significantly better for AV fistulas than for AV grafts with deployed stent-grafts. Patency of the deployed stent-graft was much better than overall AV access primary patency with deployed stent-graft. Re-stenosis with thrombosis was the most frequent indication for re-intervention. Most frequent location of re-stenosis was the draining vein (37.1 %), followed by stenosis at the AV access (29.5 %) and the deployed stent-graft (23.5 %).ConclusionRe-stenosis and re-thrombosis remain frequent in AV fistulas and AV grafts in haemodialysis patients despite stent-graft deployment. Re-stenosis of the deployed stent-graft is, only in the minority of the cases, responsible for AV access dysfunction.

  17. In Vivo Evaluation of Short-Term Performance of New Three-Layer Collagen-Based Vascular Graft Designed for Low-Flow Peripheral Vascular Reconstructions

    Directory of Open Access Journals (Sweden)

    Tomas Grus

    2018-01-01

    Full Text Available Aim. The aim of this study was to evaluate short-term patency of the new prosthetic graft and its structural changes after explantation. Methods. The study team developed a three-layer conduit composed of a scaffold made from polyester coated with collagen from the inner and outer side with an internal diameter of 6 mm. The conduit was implanted as a bilateral bypass to the carotid artery in 7 sheep and stenosis was created in selected animals. After a period of 161 days, the explants were evaluated as gross and microscopic specimens. Results. The initial flow rate (median ± IQR in grafts with and without artificial stenosis was 120±79 ml/min and 255±255 ml/min, respectively. Graft occlusion occurred after 99 days in one of 13 conduits (patency rate: 92%. Wall-adherent thrombi occurred only in sharp curvatures in two grafts. Microscopic evaluation showed good engraftment and preserved structure in seven conduits; inflammatory changes with foci of bleeding, necrosis, and disintegration in four conduits; and narrowing of the graft due to thickening of the wall with multifocal separation of the outer layer in two conduits. Conclusions. This study demonstrates good short-term patency rates of a newly designed three-layer vascular graft even in low-flow conditions in a sheep model.

  18. Graft type for femoro-popliteal bypass surgery.

    Science.gov (United States)

    Ambler, Graeme K; Twine, Christopher P

    2018-02-11

    Femoro-popliteal bypass is implemented to save limbs that might otherwise require amputation, in patients with ischaemic rest pain or tissue loss; and to improve walking distance in patients with severe life-limiting claudication. Contemporary practice involves grafts using autologous vein, polytetrafluoroethylene (PTFE) or Dacron as a bypass conduit. This is the second update of a Cochrane review first published in 1999 and last updated in 2010. To assess the effects of bypass graft type in the treatment of stenosis or occlusion of the femoro-popliteal arterial segment, for above- and below-knee femoro-popliteal bypass grafts. For this update, the Cochrane Vascular Information Specialist searched the Vascular Specialised Register (13 March 2017) and CENTRAL (2017, Issue 2). Trial registries were also searched. We included randomised trials comparing at least two different types of femoro-popliteal grafts for arterial reconstruction in patients with femoro-popliteal ischaemia. Randomised controlled trials comparing bypass grafting to angioplasty or to other interventions were not included. Both review authors (GKA and CPT) independently screened studies, extracted data, assessed trials for risk of bias and graded the quality of the evidence using GRADE criteria. We included nineteen randomised controlled trials, with a total of 3123 patients (2547 above-knee, 576 below-knee bypass surgery). In total, nine graft types were compared (autologous vein, polytetrafluoroethylene (PTFE) with and without vein cuff, human umbilical vein (HUV), polyurethane (PUR), Dacron and heparin bonded Dacron (HBD); FUSION BIOLINE and Dacron with external support). Studies differed in which graft types they compared and follow-up ranged from six months to 10 years.Above-knee bypassFor above-knee bypass, there was moderate-quality evidence that autologous vein grafts improve primary patency compared to prosthetic grafts by 60 months (Peto odds ratio (OR) 0.47, 95% confidence interval (CI

  19. Bypass grafting to the anterior tibial artery.

    Science.gov (United States)

    Armour, R H

    1976-01-01

    Four patients with severe ischaemia of a leg due to atherosclerotic occlusion of the tibial and peroneal arteries had reversed long saphenous vein grafts to the patent lower part of the anterior tibial artery. Two of these grafts continue to function 19 and 24 months after operation respectively. One graft failed on the fifth postoperative day and another occluded 4 months after operation. The literature on femorotibial grafting has been reviewed. The early failure rate of distal grafting is higher than in the case of femoropopliteal bypass, but a number of otherwise doomed limbs can be salvaged. Contrary to widely held views, grafting to the anterior tibial artery appears to give results comparable to those obtained when the lower anastomosis is made to the posterior tibial artery.

  20. The study of multi-detector CT on the grouping and measuring of the hepatic veins

    International Nuclear Information System (INIS)

    Wang Xianliang; Dong Guang; Geng Hai; Wang Wengang; Li Linkun; Gao Wei; Wang Rongfang

    2007-01-01

    Objective: To study the three-dimensional topography of the hepatic vein (HV), the inferior vena cava(IVC) and the inferior right hepatic vein(IRHV) in the retrohepatic and pre-IVC tunnel in human beings, and to provide an anatomic reference for liver surgery. Methods: One hundred and ten volunteers underwent CT scanning at 60 to 75 s after injection of contrast medium, and their HV, IVC and IRHV were reconstructed into MPR and 3D-MIP images. The hepatic veins were grouped according to the way by which the hepatic vein enters IVC. The angle between the right hepatic vein and the middle hepatic vein or the trunk of hepatic vein was measured, and the width from right hepatic vein to middle hepatic vein or to the trunk of hepatic vein on IVC was recorded. The frequency of IRHV was observed, and the length of the tunnel was measured. Results: Among the 110 volunteers, there were 6 cases (5.45%) with three hepatic veins respectively entering IVC, 98 cases (89.10%) with right hepatic vein and a common trunk of the middle hepatic vein and the left hepatic vein entering IVC, and 6 cases (5.45%) with left hepatic vein and a common trunk of the right hepatic vein and the middle hepatic vein entering IVC. The mean value of the angles between the right hepatic vein and the middle hepatic vein or the mink of hepatic vein was (55 ± 18) degree. The width from the right hepatic vein to the middle hepatic vein or to the trunk of hepatic vein was (21 ± 7)mm. The IRHV was observed in 30 cases(27.27%). The mean value of the tunnel length was (53 ± 11) mm. Conclusion: The parameters of the retrohepatic and pre-IVC tunnel in human beings can be measured accurately by the imaging of MPR, which can provide an anatomic reference for the liver surgery. (authors)

  1. Optimal temporal windows and dose-reducing strategy for coronary artery bypass graft imaging with 256-slice CT

    Energy Technology Data Exchange (ETDEWEB)

    Lu, Kun-Mu [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Lee, Yi-Wei [Department of Radiology, Kaohsiung Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Kaohsiung, Taiwan (China); Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Guan, Yu-Xiang [Department of Biomedical Imaging and Radiological Sciences, National Yang Ming University, Taipei, Taiwan (China); Chen, Liang-Kuang [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China); Law, Wei-Yip, E-mail: m002325@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); Su, Chen-Tau, E-mail: m005531@ms.skh.org.tw [Department of Radiology, Shin Kong Wu Ho-Su Memorial Hospital, 95 Wen Chang Road, Shih Lin District, Taipei 111, Taiwan. (China); School of Medicine, Fu Jen Catholic University, Taipei, Taiwan (China)

    2013-12-11

    Objective: To determine the optimal image reconstruction windows in the assessment of coronary artery bypass grafts (CABGs) with 256-slice computed tomography (CT), and to assess their associated optimal pulsing windows for electrocardiogram-triggered tube current modulation (ETCM). Methods: We recruited 18 patients (three female; mean age 68.9 years) having mean heart rate (HR) of 66.3 beats per minute (bpm) and a heart rate variability of 1.3 bpm for this study. A total of 36 CABGs with 168 segments were evaluated, including 12 internal mammary artery (33.3%) and 24 saphenous vein grafts (66.7%). We reconstructed 20 data sets in 5%-step through 0–95% of the R–R interval. The image quality of CABGs was assessed by a 5-point scale (1=excellent to 5=non-diagnostic) for each segment (proximal anastomosis, proximal, middle, distal course of graft body, and distal anastomosis). Two reviewers discriminated optimal reconstruction intervals for each CABG segment in each temporal window. Optimal windows for ETCM were also evaluated. Results: The determined optimal systolic and diastolic reconstruction intervals could be divided into 2 groups with threshold HR=68. The determined best reconstruction intervals for low heart rate (HR<68) and high heart rate (HR>68) were 76.0±2.5% and 45.0±0% respectively. Average image quality scores were 1.7±0.6 with good inter-observer agreement (Kappa=0.79). Image quality was significantly better for saphenous vein grafts versus arterial grafts (P<0.001). The recommended windows of ETCM for low HR, high HR and all HR groups were 40–50%, 71–81% and 40–96% of R-R interval, respectively. The corresponding dose savings were about 60.8%, 58.7% and 22.7% in that order. Conclusions: We determined optimal reconstruction intervals and ETCM windows representing a good compromise between radiation and image quality for following bypass surgery using a 256-slice CT.

  2. The protective effect of vein cuffed anastomoses is not mechanical in origin.

    Science.gov (United States)

    Norberto, J J; Sidawy, A N; Trad, K S; Jones, B A; Neville, R F; Najjar, S F; Sidawy, M K; DePalma, R G

    1995-04-01

    Intimal hyperplasia (IH) is a proliferative process of vascular smooth muscle cells that occurs after an arterial injury, particularly at outflow anastomoses of prosthetic bypass grafts. IH causes stenosis that leads ultimately to graft flow reduction and thrombosis. We have demonstrated previously that vein cuff interposition between an expanded polytetrafluoroethylene (e-PTFE) graft and artery at distal anastomoses diminished IH formation in the arterial outflow as compared with noncuffed anastomoses. Improved long-term patency rates associated with the placement of an interposition vein cuff at the distal anastomosis of e-PTFE grafts to infrageniculate arteries have also been demonstrated clinically. This study examined the mechanical factors that may contribute to the protective effect of cuffed anastomoses. These factors include the expansibility of the vein cuff as compared with e-PTFE, as well as the angle of the cuffed anastomosis. Compatible animals were selected by use of platelet aggregation studies. Nine dogs, group A, received a 4 mm e-PTFE graft plus a 1 cm long interposition vein cuff at the distal anastomosis in the left carotid artery. The same procedure was done on the right side, and in addition the vein cuff was encircled by an e-PTFE jacket incorporated into the anastomosis to prevent the expansion of the vein cuff with arterial pulsation. To study the effect of distal anastomotic angle and geometry on the formation of IH, five dogs, group B, received a 4 mm e-PTFE graft in both sides. On the left, the distal anastomosis was performed between the graft and the artery at an acute angle as it is commonly done when a bypass graft is placed. On the right side a 1 cm long, 6 mm diameter e-PTFE segment was interposed between the artery and the graft at a perpendicular angle. This geometry mimicked the right angle of a vein cuff-to-artery anastomosis. After 10 weeks the grafts were harvested, and the thickness of IH was measured with an ocular

  3. Three-Dimensional Bio-Printed Scaffold Sleeves With Mesenchymal Stem Cells for Enhancement of Tendon-to-Bone Healing in Anterior Cruciate Ligament Reconstruction Using Soft-Tissue Tendon Graft.

    Science.gov (United States)

    Park, Sin Hyung; Choi, Yeong-Jin; Moon, Sang Won; Lee, Byung Hoon; Shim, Jin-Hyung; Cho, Dong-Woo; Wang, Joon Ho

    2018-01-01

    To investigate the efficacy of the insertion of 3-dimensional (3D) bio-printed scaffold sleeves seeded with mesenchymal stem cells (MSCs) to enhance osteointegration between the tendon and tunnel bone in anterior cruciate ligament (ACL) reconstruction in a rabbit model. Scaffold sleeves were fabricated by 3D bio-printing. Before ACL reconstruction, MSCs were seeded into the scaffold sleeves. ACL reconstruction with hamstring tendon was performed on both legs of 15 adult rabbits (aged 12 weeks). We implanted 15 bone tunnels with scaffold sleeves with MSCs and implanted another 15 bone tunnels with scaffold sleeves without MSCs before passing the graft. The specimens were harvested at 4, 8, and 12 weeks. H&E staining, immunohistochemical staining of type II collagen, and micro-computed tomography of the tunnel cross-sectional area were evaluated. Histologic assessment was conducted with a histologic scoring system. In the histologic assessment, a smooth bone-to-tendon transition through broad fibrocartilage formation was identified in the treatment group, and the interface zone showed abundant type II collagen production on immunohistochemical staining. Bone-tendon healing histologic scores were significantly higher in the treatment group than in the control group at all time points. Micro-computed tomography at 12 weeks showed smaller tibial (control, 9.4 ± 0.9 mm 2 ; treatment, 5.8 ± 2.9 mm 2 ; P = .044) and femoral (control, 9.6 ± 2.9 mm 2 ; treatment, 6.0 ± 1.0 mm 2 ; P = .03) bone-tunnel areas in the treated group than in the control group. The 3D bio-printed scaffold sleeve with MSCs exhibited excellent results in osteointegration enhancement between the tendon and tunnel bone in ACL reconstruction in a rabbit model. If secure biological healing between the tendon graft and tunnel bone can be induced in the early postoperative period, earlier, more successful rehabilitation may be facilitated. Three-dimensional bio-printed scaffold sleeves with

  4. Early integration of a bone plug in the femoral tunnel in rectangular tunnel ACL reconstruction with a bone-patellar tendon-bone graft: a prospective computed tomography analysis.

    Science.gov (United States)

    Suzuki, Tomoyuki; Shino, Konsei; Nakagawa, Shigeto; Nakata, Ken; Iwahashi, Takehiko; Kinugasa, Kazutaka; Otsubo, Hidenori; Yamashita, Toshihiko

    2011-12-01

    The purpose of this prospective study was to evaluate how early the bone plug was integrated into the rectangular femoral tunnel after anatomical ACL reconstruction using a bone-patellar tendon-bone (BTB) graft via a rectangular tunnel (RT BTB ACL-R). Twenty consecutive patients who had undergone the reconstruction procedure were evaluated by CT scans at 4 and 8 weeks postoperatively. In each scan, 30 slices for multiplanar reconstruction were collected parallel to the long axis of the parallelepiped femoral tunnel and perpendicular to the tendinous plane of the bone plug. Each slice was classified as "complete," indicating no visible gap between the plug and the tunnel wall or trabecular continuity or "incomplete," showing a visible gap. Bone plug-tunnel integration was evaluated as "excellent," "good," "fair," or "poor" for >20, 11-20, 5-10, and values at the anterior interface between the bone plug and the tunnel wall were also measured on both scans. The mean changes in CT value at 8 weeks were significantly lower than those at 4 weeks. This study shows that bone plug-femoral tunnel integration was almost complete by 8 weeks after surgery using RT BTB ACL-R.

  5. Gd-DTPA-enhanced MR venography for varicose veins of the calf

    International Nuclear Information System (INIS)

    Kohata, Yoshiko; Naito, Akira; Ito, Katuhide.

    1995-01-01

    2D time-of-flight MR venography (2D TOF MRV) was performed in 16 patients (25 calves) with varicose veins and 2 volunteers (4 calves), and compared with venography. Sequential SPGR (TR/TE/FA=45 ms/7 ms/60deg) transverse images and/or GRASS (TR/TE/FA=100 ms/13 ms/60deg) transverse images were obtained for MRV. Superior presaturation pulse (S-SAT) was placed in 21 calves, and 0.05 mmol/kg Gd-DTPA was used in all calves. Projection MRVs were generated with maximum intensity projection (MIP) reconstruction. Regarding sequence parameter, S-SAT was useful to eliminate signal from artery that would obscure the signal of deep veins. The detectability of deep veins was improved with the use of S-SAT. In the comparison with venography, MRV could more clearly demonstrate varicose veins more than 5 mm in diameter and their drainage veins than venography. But it could not so clearly demonstrate deep veins as venography. It could not detect fine varicose veins less than 5 mm in diameter and connecting veins with valve insufficiency. In the examination of varicose veins, detection of deep veins, large varicose veins and their main drainage veins is clinically important, because diagnosis of patency of deep veins and dilatation of the drainage veins is necessary to choose the treatment, concluding conservative therapy, stripping and sclerotherapy. However, detection of fine varicose veins and connecting veins are not so important because those veins seldom need treatment. MRV was not so suitable for detection of deep veins, but very useful for detection of varicose veins more than 5 mm in diameter and their main drainage veins. In conclusion, MRV is non-invasive and effective method in varicose veins of calf, and it can take the place of venography with the improvement of deep vein detectability. (author)

  6. Edema de membro inferior secundário a exérese de veia safena magna para utilização como enxerto na revascularização do miocárdio Lower limb edema after great saphenous vein harvesting to be used as graft in myocardial revascularization

    Directory of Open Access Journals (Sweden)

    Cleusa Ema Quilici Belczak

    2009-03-01

    Full Text Available CONTEXTO: A revascularização do miocárdio utilizando-se a veia safena magna ainda é procedimento cirúrgico bastante realizado na atualidade. O edema que surge no membro inferior operado causa grande desconforto e necessita ser melhor estudado. OBJETIVOS: Caracterizar o edema de membro inferior secundário a exérese da veia safena magna pela técnica de incisões escalonadas para sua utilização como enxerto venoso na revascularização do miocárdio. MÉTODOS: Foram selecionados aleatoriamente 44 indivíduos submetidos a exérese de veia safena magna para revascularização miocárdica há mais de 3 meses. Excluíram-se fatores que pudessem interferir na formação de edema dos membros inferiores. Foram avaliados por volumetria e perimetria maleolares ambos os membros inferiores. Considerou-se como presença de edema significativo a diferença de volume maior que 50 mL e maior de 2 cm em relação ao membro não-operado. Para a análise estatística foram empregados o teste do qui-quadrado, teste exato de Fisher, teste t de Student e o teste de McNemar. O nível de significância adotado foi de 5% (a = 0,05. RESULTADOS: Encontraram-se diferenças estatisticamente significativas (p BACKGROUND: Myocardial revascularization using the great saphenous vein is still a very common surgical procedure. The edema that occurs in the operated leg causes much discomfort and requires further studies. OBJECTIVES: To describe lower limb edema secondary to great saphenous vein harvesting using the bridge technique for use as venous graft in myocardial revascularization. METHODS: Forty-four individuals previously submitted to great saphenous vein harvesting for myocardial revascularization more than 3 months before were randomly selected. Patients with factors that might interfere with formation of lower limb edema were excluded. Both operated and non-operated legs were evaluated by volumetry and perimetry of the malleolar region. Differences greater than

  7. Nanofat grafting under a split-thickness skin graft for problematic wound management.

    Science.gov (United States)

    Kemaloğlu, Cemal Alper

    2016-01-01

    Obesity and certain medical disorders make the reconstruction of skin defects challenging. Different kind of procedure can be used for these defect, besides, skin grafting is one of the most common and simplest procedure. Fat grafting and stem cells which are located in the adipose tissue have been commonly used in plastic surgery for regeneration and rejuvenation purposes. To decrease graft failure rate we performed nanofat grafting under an autologous split-thickness skin graft in our patient who had a problematic wound. The case of a 35-year-old female patient with a traumatic skin defect on her left anterior crural region is described herein. After subsequent flap reconstruction, the result was disappointing and the defect size was widened. The defect was treated with combined grafting (nanofat grafting under an autologous split-thickness skin graft). At the 6 months follow-up assessment after combined grafting, the integrity of the skin graft was good with excellent pliability. Combined grafting for problematic wounds seems to be a useful technique for cases requiring reconstruction. The potential existence of stem cells may be responsible for the successful result in our patient.

  8. Use of the Anterolateral Thigh and Vertical Rectus Abdominis Musculocutaneous Flaps as Utility Flaps in Reconstructing Large Groin Defects

    Directory of Open Access Journals (Sweden)

    Edwin Jonathan Aslim

    2014-09-01

    Full Text Available BackgroundGroin dissections result in large wounds with exposed femoral vessels requiring soft tissue coverage, and the reconstructive options are diverse. In this study we reviewed our experience with the use of the pedicled anterolateral thigh and vertical rectus abdominis musculocutaneous flaps in the reconstruction of large groin wounds.MethodsGroin reconstructions performed over a period of 10 years were evaluated, with a mean follow up of two years. We included all cases with large or complex (involving perineum defects, which were reconstructed with the pedicled anterolateral thigh musculocutaneous or the vertical rectus abdominis musculocutaneous (VRAM flaps. Smaller wounds which were covered with skin grafts, locally based flaps and pedicled muscle flaps were excluded.ResultsTwenty-three reconstructions were performed for large or complex groin defects, utilising the anterolateral thigh (n=10 and the vertical rectus abdominis (n=13 pedicled musculocutaneous flaps. Femoral vein reconstruction with a prosthetic graft was required in one patient, and a combination flap (VRAM and gracilis muscle flap was performed in another. Satisfactory coverage was achieved in all cases without major complications. No free flaps were used in our series.ConclusionsThe anterolateral thigh and vertical rectus abdominis pedicled musculocutaneous flaps yielded consistent results with little morbidity in the reconstruction of large and complex groin defects. A combination of flaps can be used in cases requiring extensive cover.

  9. Interventions in Infrainguinal Bypass Grafts

    International Nuclear Information System (INIS)

    Mueller-Huelsbeck, S.; Order, B.-M.; Jahnke, T.

    2006-01-01

    The interventional radiologist plays an important role in the detection and prevention of infrainguinal bypass failure. Early detection and evaluation of flow-limiting lesions effectively preserve graft (venous bypass and polyester or expanded polytetrafluoroethylene bypass) patency by identifying stenoses before occlusion occurs. Delay in treatment of the at-risk graft may result in graft failure and a reduced chance of successful revascularization. For this reason, surveillance protocols form an important part of follow-up after infrainguinal bypass surgery. As well as having an understanding of the application of imaging techniques including ultrasound, MR angiography, CT angiography and digital subtraction angiography, the interventional radiologist should have detailed knowledge of the minimally invasive therapeutic options. Percutaneous transluminal angioplasty (PTA), or alternatively cutting balloon angioplasty, is the interventional treatment of choice in prevention of graft failure and occlusion. Further alternatives include metallic stent placement, fibrinolysis, and mechanical thrombectomy. Primary assisted patency rates following PTA can be up to 65% at 5 years. When the endovascular approach is unsuccessful, these therapeutic options are complemented by surgical procedures including vein patch revision, jump grafting, or placement of a new graft

  10. Vaginal reconstruction

    International Nuclear Information System (INIS)

    Lesavoy, M.A.

    1985-01-01

    Vaginal reconstruction can be an uncomplicated and straightforward procedure when attention to detail is maintained. The Abbe-McIndoe procedure of lining the neovaginal canal with split-thickness skin grafts has become standard. The use of the inflatable Heyer-Schulte vaginal stent provides comfort to the patient and ease to the surgeon in maintaining approximation of the skin graft. For large vaginal and perineal defects, myocutaneous flaps such as the gracilis island have been extremely useful for correction of radiation-damaged tissue of the perineum or for the reconstruction of large ablative defects. Minimal morbidity and scarring ensue because the donor site can be closed primarily. With all vaginal reconstruction, a compliant patient is a necessity. The patient must wear a vaginal obturator for a minimum of 3 to 6 months postoperatively and is encouraged to use intercourse as an excellent obturator. In general, vaginal reconstruction can be an extremely gratifying procedure for both the functional and emotional well-being of patients

  11. Bilateral meandering pulmonary veins

    Energy Technology Data Exchange (ETDEWEB)

    Thupili, Chakradhar R.; Udayasankar, Unni [Pediatric Imaging, Imaging Institute Cleveland Clinic, Cleveland, OH (United States); Renapurkar, Rahul [Imaging Institute Cleveland Clinic, Thoracic Imaging, L10, Cleveland, OH (United States)

    2015-06-15

    Meandering pulmonary veins is a rare clinical entity that can be mistaken for more complex congenital syndromes such as hypogenetic lung syndrome. We report imaging findings in a rare incidentally detected case of bilateral meandering pulmonary veins. We briefly discuss the role of imaging in diagnosing this condition, with particular emphasis on contrast-enhanced CT. (orig.)

  12. Deep Vein Thrombosis

    African Journals Online (AJOL)

    OWNER

    Deep Vein Thrombosis: Risk Factors and Prevention in Surgical Patients. Deep Vein ... preventable morbidity and mortality in hospitalized surgical patients. ... the elderly.3,4 It is very rare before the age ... depends on the risk level; therefore an .... but also in the post-operative period. ... is continuing uncertainty regarding.

  13. Forças mecânicas e veias safenas humanas: implicação na revascularização do miocárdio Mechanical forces and human saphenous veins: coronary artery bypass graft implications

    Directory of Open Access Journals (Sweden)

    Rafael Angelo Tineli

    2007-03-01

    Full Text Available As células endoteliais vasculares estão expostas a uma variedade de forças mecânicas in vivo, resultantes do fluxo sangüíneo pulsátil. Dentre essas forças, destacam-se: forças de cisalhamento, tangenciais à parede do vaso, produzidas pelo atrito com o fluxo sangüíneo viscoso, tensão de complacência da parede vascular e a pressão hidrostática do conteúdo sangüíneo no interior da vasculatura. Diversos autores estudaram as alterações hemodinâmicas, funcionais e morfológicas em veias safenas humanas causadas por esses tipos de forças com resultados conflitantes. A motivação dessa revisão foi analisar dados da literatura e alguns dados experimentais do nosso laboratório. Os aspectos revistos são: 1 Respostas endoteliais e regulação gênica causadas pelo shear stress; 2 Efeitos da pressão hidrostática na morfologia da célula endotelial, expressão gênica da superfície celular endotelial e proliferação das células endoteliais, 3 Efeitos da tração no endotélio de veias safenas humanas.Vascular endothelial cells are exposed to a variety of in vivo mechanical forces, specifically, shear stress for the blood flow, tensile stress from the compliance of the vessel wall and the hydrostatic pressure from containment of blood within inside the vasculature. Many authors studied hemodynamic, functional and morphological human saphenous veins alterations caused by these different forces with conflictant results. This review text was motivated with the specific aim of analyze literature data and some experimental data carried out in our laboratory. The adopted review subjects were: 1 Endothelial responses and gene regulation to shear stress; 2 Effects of the hydrostatic pressure in the endothelial cell morphology, gene expression of the endothelial cellular surface and proliferation of endothelial cells; 3 Effects of the traction on the human saphenous vein endothelium.

  14. Current status of grafts and implants in rhinoplasty: Part II. Homologous grafts and allogenic implants.

    Science.gov (United States)

    Sajjadian, Ali; Naghshineh, Nima; Rubinstein, Roee

    2010-03-01

    After reading this article, the participant should be able to: 1. Understand the challenges in restoring volume and structural integrity in rhinoplasty. 2. Identify the appropriate uses of various homologous grafts and allogenic implants in reconstruction, including: (a) freeze-dried acellular allogenic cadaveric dermis grafts, (b) irradiated cartilage grafts, (c) hydroxyapatite mineral matrix, (d) silicone implants, (e) high-density polyethylene implants, (f) polytetrafluoroethylene implants, and (g) injectable filler materials. 3. Identify the advantages and disadvantages of each of these biomaterials. 4. Understand the specific techniques that may aid in the use these grafts or implants. This review specifically addresses the use of homologous grafts and allogenic implants in rhinoplasty. It is important to stress that autologous materials remain the preferred graft material for use in rhinoplasty, owing to their high biocompatibility and low risk of infection and extrusion. However, concerns of donor-site morbidity, graft availability, and graft resorption have motivated the development and use of homologous and allogenic implants.

  15. Quantifying Long-term Retention of Excised Fat Grafts

    DEFF Research Database (Denmark)

    Herly, Mikkel; Ørholt, Mathias; Glovinski, Peter V.

    2017-01-01

    Background: Predicting the degree of fat graft retention is essential whenplanning reconstruction or augmentation with free fat grafting. Most surgeonsobserve volume loss over time after fat grafting; however, the portion lost toresorption after surgery is still poorly defined, and the time to re...

  16. The effect on patency of type, shape and volume of a vein collar used at the distal anastomis of PTFE-bypass to arteries below-knee

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    The aim of this paper was to study the effect on patency rate of different types of vein collar (Miller's original or St Mary's boot), different length/height shapes of vein collar, and different vein collar volumes at the distal anastomosis of PTFE-bypass grafts to below-knee arteries in patients...

  17. Pancreas grafts

    International Nuclear Information System (INIS)

    Hahn, D.; Buell, U.; Land, W.; Unertl, K.

    1981-01-01

    Perfusion studies with sup(99m)Tc-DTPA, which has hitherto been used routinely to investigate renal grafts, have also proved useful for monitoring the perfusion of pancreas grafts. A total perfusion failure is equally reliably demonstrable as in renal grafts. Quantitatively smaller perfusion alterations can be demonstrated by monitoring the course. It seems possible to differentiate the salivary edema of a rejection reaction, well known from animal experiments, with the help of other paramters (e.g. creatinine). Further clinical studies are however necessary to confirm these results. (orig.) [de

  18. Different techniques of vessel reconstruction during kidney transplantation

    Directory of Open Access Journals (Sweden)

    Tomić Aleksandar

    2015-01-01

    Full Text Available Background/Aim. Multiple renal arteries (MRAs represent a surgical challenge by the difficulty in performing anastomoses, bleeding and stenosis. MRAs should be preserved and special attention should be paid to accessory polar arteries. All renal arteries (RAs must be reconstructed and prepared for safe anastomosis. The paper decribed the different techniques of vessel reconstruction during kidney transplantation including important steps within recovery of organs, preparation and implantation. Methods. In a 16-year period (1996-2012 of kidney transplantation in the Military Medical Academy, Belgrade, a total of 310 living donors and 44 human cadaver kidney transplantations were performed, of which 28 (8% kidneys had two or more RAs. Results. All the transplanted kidneys had immediate function. We repaired 20 cases of donor kidneys with 2 arteries, 4 cases with three RAs, one case with 4 RAs, one case with 4 RAs and renal vein reconstruction, one case with 3 arteries and additional polytetrafluoroethylene (PTFE graft reconstruction, one case with transected renal artery and reconstruction with 5 cm long deceased donor external iliac artery. There were no major complications and graft failure. At a minimum of 1-year follow-up, all the patients showed normal renal function. Conclusion. Donor kidney transplantation on a contralateral side and “end-to-end” anastomosis of the renal artery to the internal iliac artery (IIA is our standard procedure with satisfactory results. Renal artery reconstruction and anastomosis with IIA is a safe and highly efficient procedure and kidneys with MRAs are not contraindicated for transplantation. A surgical team should be fully competent to remove cadaveric abdominal organs to avoid accidental injuries of organs vessels.

  19. Endovascular vein harvest: systemic carbon dioxide absorption.

    Science.gov (United States)

    Maslow, Andrew M; Schwartz, Carl S; Bert, Arthur; Hurlburt, Peter; Gough, Jeffrey; Stearns, Gary; Singh, Arun K

    2006-06-01

    Endovascular vein harvest (EDVH) requires CO(2) insufflation to expand the subcutaneous space, allowing visualization and dissection of the saphenous vein. The purpose of this study was to assess the extent of CO(2) absorption during EDVH. Prospective observational study. Single tertiary care hospital. Sixty patients (30 EDVH and 30 open-vein harvest) undergoing isolated coronary artery bypass graft surgery. Hemodynamic, procedural, and laboratory data were collected prior to (baseline), during, and at it the conclusion (final) of vein harvesting. Data were also collected during cardiopulmonary bypass (CPB). Data were compared by using t tests, analysis of variance, and correlation statistics when needed. There were significant increases in arterial CO(2) (PaCO(2), 35%) and decreases in pH (1.35%) during EDVH. These were associated with increases in heart rate, mean blood pressure, and cardiac output. Within the EDVH group, greater elevations (>10 mmHg) in PaCO2 were more likely during difficult harvest procedures, and these patients exhibited greater increase in heart rate. Elevated CO(2) persisted during CPB, requiring higher systemic gas flows and greater use of phenylephrine to maintain desired hemodynamics. EDVH was associated with systemic absorption of CO(2). Greater absorption was more likely in difficult procedures and was associated with greater hemodynamic changes requiring medical therapy.

  20. Skull Bone Defects Reconstruction with Custom-Made Titanium Graft shaped with Electron Beam Melting Technology: Preliminary Experience in a Series of Ten Patients.

    Science.gov (United States)

    Francaviglia, Natale; Maugeri, Rosario; Odierna Contino, Antonino; Meli, Francesco; Fiorenza, Vito; Costantino, Gabriele; Giammalva, Roberto Giuseppe; Iacopino, Domenico Gerardo

    2017-01-01

    Cranioplasty represents a challenge in neurosurgery. Its goal is not only plastic reconstruction of the skull but also to restore and preserve cranial function, to improve cerebral hemodynamics, and to provide mechanical protection of the neural structures. The ideal material for the reconstructive procedures and the surgical timing are still controversial. Many alloplastic materials are available for performing cranioplasty and among these, titanium still represents a widely proven and accepted choice. The aim of our study was to present our preliminary experience with a "custom-made" cranioplasty, using electron beam melting (EBM) technology, in a series of ten patients. EBM is a new sintering method for shaping titanium powder directly in three-dimensional (3D) implants. To the best of our knowledge this is the first report of a skull reconstruction performed by this technique. In a 1-year follow-up no postoperative complications have been observed and good clinical and esthetic outcomes were achieved. Costs higher than those for other types of titanium mesh, a longer production process, and the greater expertise needed for this technique are compensated by the achievement of most complex skull reconstructions with a shorter operative time.

  1. Two-Stage Liver Transplantation with Temporary Porto-Middle Hepatic Vein Shunt

    Directory of Open Access Journals (Sweden)

    Giovanni Varotti

    2010-01-01

    Full Text Available Two-stage liver transplantation (LT has been reported for cases of fulminant liver failure that can lead to toxic hepatic syndrome, or massive hemorrhages resulting in uncontrollable bleeding. Technically, the first stage of the procedure consists of a total hepatectomy with preservation of the recipient's inferior vena cava (IVC, followed by the creation of a temporary end-to-side porto-caval shunt (TPCS. The second stage consists of removing the TPCS and implanting a liver graft when one becomes available. We report a case of a two-stage total hepatectomy and LT in which a temporary end-to-end anastomosis between the portal vein and the middle hepatic vein (TPMHV was performed as an alternative to the classic end-to-end TPCS. The creation of a TPMHV proved technically feasible and showed some advantages compared to the standard TPCS. In cases in which a two-stage LT with side-to-side caval reconstruction is utilized, TPMHV can be considered as a safe and effective alternative to standard TPCS.

  2. Limb salvage and reconstruction following a zebra attack

    Directory of Open Access Journals (Sweden)

    Jacob T. Carlson

    2017-06-01

    Full Text Available Animal bites are fairly rare events but can cause devastating traumatic injuries to the victim. In addition to the soft tissue, vascular, and orthopedic trauma inflicted by these occurrences, bite injuries also have the potential to introduce an inoculum of microbes, which may progress to an infection if not treated properly and expeditiously.We present the case of a healthy male who sustained multiple bite wounds from a domestic zebra to his left upper extremity. This attack caused severe damage, including devascularization of the arm at the brachial artery, disruption of the distal biceps and brachialis, stripping of the forearm nerves, and shearing of the overlying soft tissue. The patient was taken emergently to the operating room for revascularization of the extremity utilizing a vein bypass graft. The soft tissue injuries were addressed with numerous irrigation and debridement procedures, during which coverage of the vein bypass graft was obtained using a variety of techniques, including skin flaps, musculocutaneous advancements, and the application of an acellular dermal matrix (AlloDerm and a collagen-glycosaminoglycan matrix (Integra.Wound cultures obtained intra-operatively during the irrigation and debridement procedures were notable for the growth of multiple microbes, including Rhodococcus spp., which have been documented to cause infection in immunocompromised patients. The patient in this case was treated with a prolonged course of antibiotics, and wound cultures negative for microbial growth were eventually obtained prior to final closure of his wound. The patient then underwent successful biceps reconstruction with a pedicled latissimus dorsi muscle transfer. This case documents the extraordinary multidisciplinary approach provided in the salvage, management, and eventual reconstruction of a mangled left upper extremity that had sustained devastating traumatic injuries resulting from a rather unusual source. Keywords: Zebra

  3. Continuous Perfusion of Saphenous Vein by Oxygenated Blood during Beating Coronary Surgery

    Directory of Open Access Journals (Sweden)

    Mohammad Hossein Mandegar

    2015-09-01

    Full Text Available Background: The saphenous vein remains the most commonly used conduit for coronary artery bypass surgery (CABG. However, the long-term success of surgical revascularization is largely limited by development of occlusion in vein grafts. Objectives: We sought to reduce graft ischemia by maintaining the blood flow into the harvested vein throughout surgery at lowest costs and without special devices. Patients and Methods: This study was conducted on three hundred patients aged 58.5 ± 8 years undergoing elective first-time off-pump CABG with saphenous veins. Results: In addition to preserving nutritional materials and oxygen, the veins harvested via this novel technique did not go into spasm and were not subjected to high-pressure distension, eventually resulting in minimal damage to the endothelium. Conclusions: This technique confers favorable myocardial function and protection in the presence of left ventricular dysfunction, especially in elderly patients.

  4. Three-Dimensional Cone Beam Computed Tomography Volumetric Outcomes of rhBMP-2/Demineralized Bone Matrix versus Iliac Crest Bone Graft for Alveolar Cleft Reconstruction.

    Science.gov (United States)

    Liang, Fan; Yen, Stephen L-K; Imahiyerobo, Thomas; Sanborn, Luke; Yen, Leia; Yen, Daniel; Nazarian, Sheila; Jedrzejewski, Breanna; Urata, Mark; Hammoudeh, Jeffrey

    2017-10-01

    Recent studies indicate that recombinant human bone morphogenetic protein-2 (rhBMP-2) in a demineralized bone matrix scaffold is a comparable alternative to iliac bone autograft in the setting of secondary alveolar cleft repair. Postreconstruction occlusal radiographs demonstrate improved bone stock when rhBMP-2/demineralized bone matrix (DBM) scaffold is used but lack the capacity to evaluate bone growth in three dimensions. This study uses cone beam computed tomography to provide the first clinical evaluation of volumetric and density comparisons between these two treatment modalities. A prospective study was conducted with 31 patients and 36 repairs of the alveolar cleft over a 2-year period. Twenty-one repairs used rhBMP-2/DBM scaffold and 14 repairs used iliac bone grafting. Postoperatively, occlusal radiographs were obtained at 3 months to evaluate bone fill; cone beam computed tomographic images were obtained at 6 to 9 months to compare volumetric and density data. At 3 months, postoperative occlusal radiographs demonstrated that 67 percent of patients receiving rhBMP-2/DBM scaffold had complete bone fill of the alveolus, versus 56 percent of patients in the autologous group. In contrast, cone beam computed tomographic data showed 31.6 percent (95 percent CI, 24.2 to 38.5 percent) fill in the rhBMP-2 group compared with 32.5 percent (95 percent CI, 22.1 to 42.9 percent) in the autologous population. Density analysis demonstrated identical average values between the groups (1.38 g/cc). These data demonstrate comparable bone regrowth and density values following secondary alveolar cleft repair using rhBMP-2/DBM scaffold versus autologous iliac bone graft. Cone beam computed tomography provides a more nuanced understanding of true bone regeneration within the alveolar cleft that may contribute to the information provided by occlusal radiographs alone. Therapeutic, II.

  5. Bone graft viability evaluated by three phase bone scan

    International Nuclear Information System (INIS)

    Ljiljana Jaukovic Rajko Spaic; Marijan Novakovic; Srbislav Stosic

    2004-01-01

    Bone defects resulting war injury can be replaced by microvascular bone grafts from fibula. Aim: The aim of this study was to assess the value of three phase (3P) bone scintigraphy in the early detection of the bone graft complications. Method: 3P bone scans were performed in four patients (two after mandible reconstruction with micro vascular fibular bone grafts, one after fibular transplantation for ulnar and one with humeral reconstruction). First dynamic phase scan was performed immediately after iv injection of 740 MBq Tc- 99m DPD, acquiring 15 two seconds duration frames. Second, early static scan was performed during next 300 seconds, and third, delayed scan three hours later. All scans were obtained under the bone graft region. The scans were evaluated using ROI under graft region and the corresponding contra lateral area. Blood flow in graft region was determined using first phase scan, and tracer uptake in the same region was determined using second and third phase scans. Results: in all patients blood flow in graft region was particularly normal. Tracer uptake in one of two patients with mandible reconstruction was diffusely increased in graft, strongly suggesting infection; In the other patient delayed scan showed no tracer uptake in graft center .Both patients with ulnar and humeral reconstruction showed only slightly decreased tracer uptake in bone grafts. 3 phase bone scintigraphy may play a role in the evaluation of bone graft viability by predicting the infection and necrosis. (authors)

  6. Preventing Deep Vein Thrombosis

    Science.gov (United States)

    ... Physicians Contact Us My ACOG ACOG Departments Donate Shop Career Connection Home Clinical Guidance & Publications Practice Management ... skin. A clot also can form if blood flow is too slow the lining of a vein ...

  7. Depth of the graft bed influences split-skin graft contraction.

    NARCIS (Netherlands)

    Mensik, I.; Lamme, E.N.; Brychta, P.

    2003-01-01

    Contraction of a split-thickness skin graft used for coverage of large defects remains a great problem in plastic, burn and reconstructive surgery. In this study we evaluated healing of split-thickness skin grafts transplanted in wounds on the subcutaneous fat and muscle fascia in pigs. Four young

  8. An objective long-term evaluation of Integra (a dermal skin substitute) and split thickness skin grafts, in acute burns and reconstructive surgery.

    Science.gov (United States)

    Nguyen, Dai Q A; Potokar, Tom S; Price, Patricia

    2010-02-01

    The field of wound healing and tissue repair has advanced rapidly in the last decade, with this there is an increasing emphasis on the importance of the functional and cosmetic outcomes following injury. Integra artificial skin is the most widely used synthetic skin substitute and is reported to have better outcomes in relation to the appearance and elasticity when compared to split thickness skin grafting (SSG). A review of the literature reveals very few trials that are based on an objective evaluation of Integra treated scars as compared to SSGs. This research aimed to provide objective data on the long-term outcome of Integra. All adult patients from the Welsh Burns Centre who had been successfully treated with Integra+/-SSG were invited to attend a clinic for a follow up provided they had been healed for greater than one year. The hypothesis that Integra scars are more pliable than skin grafts was tested objectively using the Cutometer, a suction device which measures skin elasticity. Of the 13 patients eligible, six were available for assessment. The results of this study suggest that Integra treated sites correlate well with normal skin as measured by the Cutometer. This was statistically significant for the parameters Ur/Ue (elastic function) and Ur/Uf (gross elasticity). On the other hand there was no correlation seen between the patients SSG sites and the patient's normal skin. With advances in medicine we are increasingly able to modulate wound healing and the resultant scars. In order to assess new and often costly treatments the need for objective scar measurement tools have become apparent. Integra has been advocated to improve scarring from injury. However, there have been few studies to evaluate the long-term outcome of Integra as compared to traditional methods such as SSG. In the past scar evaluation has been based on subjective scores by patients and clinicians. Now the mechanical properties of the skin can be evaluated using simple

  9. Construction of tissue-engineered small-diameter vascular grafts in fibrin scaffolds in 30 days.

    Science.gov (United States)

    Gui, Liqiong; Boyle, Michael J; Kamin, Yishai M; Huang, Angela H; Starcher, Barry C; Miller, Cheryl A; Vishnevetsky, Michael J; Niklason, Laura E

    2014-05-01

    Tissue-engineered small-diameter vascular grafts have been developed as a promising alternative to native veins or arteries for replacement therapy. However, there is still a crucial need to improve the current approaches to render the tissue-engineered blood vessels more favorable for clinical applications. A completely biological blood vessel (3-mm inner diameter) was constructed by culturing a 50:50 mixture of bovine smooth muscle cells (SMCs) with neonatal human dermal fibroblasts in fibrin gels. After 30 days of culture under pulsatile stretching, the engineered blood vessels demonstrated an average burst pressure of 913.3±150.1 mmHg (n=6), a suture retention (53.3±15.4 g) that is suitable for implantation, and a compliance (3.1%±2.5% per 100 mmHg) that is comparable to native vessels. These engineered grafts contained circumferentially aligned collagen fibers, microfibrils and elastic fibers, and differentiated SMCs, mimicking a native artery. These promising mechanical and biochemical properties were achieved in a very short culture time of 30 days, suggesting the potential of co-culturing SMCs with fibroblasts in fibrin gels to generate functional small-diameter vascular grafts for vascular reconstruction surgery.

  10. Reconstruction of cervical scar contracture using axial thoracic flap based on the thoracic branch of the supraclavicular artery.

    Science.gov (United States)

    Ma, Xianjie; Li, Yang; Wang, Lu; Li, Weiyang; Dong, Liwei; Xia, Wei; Su, Yingjun

    2014-09-01

    Cervical scar contracture causes both physical and psychological distress for burn patients. Many pedicle flaps or skin grafting have been suggested for reconstruction of cervical scar contracture with variable results in the literature. The authors present the axial thoracic flap based on the thoracic branch of the supraclavicular artery (TBSA) for reconstruction of cervical scar contracture. Postburn scar contractures in anterior neck region of 66 patients had been reconstructed with the axial pattern thoracic flaps based on the TBSA, including 1 expanded and 10 nonexpanded pedicle flaps, and 9 expanded and 46 nonexpanded island pedicle flaps, during 1988 through 2012. After removing and releasing the cervical scar contracture, the flap was designed in the thoracic region. The axial artery of the flap is the TBSA bifurcating from the intersection point of sternocleidomastoid muscle and omohyoid muscle with several concomitant veins as the axial veins. The flap can be designed in a large area within the borders of the anterior border of the trapezius muscle superiorly, the middle part of the deltoid muscle laterally, the midsternal line medially, and the level 3 to 4 cm below nipples inferiorly. After incisions were made along the medial, inferior, and lateral border, dissection was performed toward the pedicle. Donor site was closed directly in expanded cases and with skin grafting in nonexpanded cases. Cervical scar contractures were repaired with good functional and cosmetic results in 64 cases among this cohort. Flap tip necrosis in other 2 cases, caused by postoperative hematoma, was repaired by skin grafting. The color and texture of all flaps were fitted with those of the surrounding skin. The donor sites all healed primarily. The flap sensation in the thoracic region regained in the early stage postoperatively and that in cervical area recovered completely after 6 months according to the report of the patients. With reliable blood supply based on the

  11. Gastric pull-up reconstruction combined with free jejunal transfer (FJT) following total pharyngolaryngo-oesophagectomy (PLE).

    Science.gov (United States)

    Ni, Song; Zhu, Yiming; Li, Dezhi; Li, Zhengjiang; Wu, Yuehuang; Xu, Zhengang; Liu, Shaoyan

    2015-06-01

    Reconstruction following total pharyngolaryngo-oesophagectomy (PLE) still challenges surgeons because of the extreme length of removed tissue. Gastric pull-up reconstruction, one of the most common reconstructive methods after PLE, has many complications such as anastomotic fistula and gastric necrosis caused by the high anastomotic tension. However, modifications of gastric pull-up reconstruction aiming to reducing the high anastomotic tension have been less reported compared with other aspects with this technique. Here we report a modified gastric pull-up reconstruction combined with free jejunal transfer (FTJ) to reduce the anastomosis tension, and thus to reduce the risk of complications after PLE. Patients underwent a standard surgical procedure including total pharyngolaryngo-oesophagectomy and bilateral internal jugular lymph nodal clearance. A free jejunal graft about 10 cm was harvested and placed in the appropriate position between mobilized stomach and oropharynx. The anastomosis between the free jejunal graft and the gastric tube was created through a stapler. Vascular anastomosis was made between the jejunal artery and the transverse cervical artery, and between the jejunal vein and the internal jugular vein. Hand suturing technique was used in the anastomosis between jejunum and pharynx. None of the patients suffered from any complications such as anastomotic fistula. Both patients resumed early postoperative oral intake. So far, they remain free of tumor recurrence and are in good health for 46 and 18 months, respectively. Considering the tumor status and the patient condition, the gastric pull-up reconstruction combined with FJT after PLE could be a reliable choice. Copyright © 2015 IJS Publishing Group Limited. Published by Elsevier Ltd. All rights reserved.

  12. Secondary bone grafting for alveolar cleft in children with cleft lip or cleft lip and palate

    NARCIS (Netherlands)

    Guo, J.; Li, C.; Zhang, Q.; Wu, G.; Deacon, S.A.; Chen, J.; Hu, H.; Zou, S.; Ye, Q.

    2011-01-01

    BACKGROUND: Secondary alveolar bone grafting has been widely used to reconstruct alveolar cleft. However, there is still some controversy. OBJECTIVES: To compare the effectiveness and safety of different secondary bone grafting methods. SEARCH STRATEGY: The final electronic and handsearches were

  13. Development of a one-step approach for the reconstruction of full thickness skin defects using minced split thickness skin grafts and biodegradable synthetic scaffolds as a dermal substitute.

    Science.gov (United States)

    Sharma, Kavita; Bullock, Anthony; Ralston, David; MacNeil, Sheila

    2014-08-01

    Tissue engineering has progressed in delivering laboratory-expanded keratinocytes to the clinic; however the production of a suitable alternative to a skin graft, containing both epidermis and dermis still remains a challenge. To develop a one-step approach to wound reconstruction using finely minced split thickness skin and a biodegradable synthetic dermal substitute. This was explored in vitro using scalpel diced pieces of split thickness human skin combined with synthetic electrospun polylactide (PLA) scaffolds. To aid the spreading of tissue, 1% methylcellulose was used and platelet releasate was examined for its effect on cellular outgrowth from tissue explants. The outcome parameters included the metabolic activity of the migrating cells and their ability to produce collagen. Cell presence and migration on the scaffolds were assessed using fluorescence microscopy and SEM. Cells were identified as keratinocytes by immunostaining for pan-cytokeratin. Collagen deposition was quantified by using Sirius red. Skin cells migrated along the fibers of the scaffold and formed new collagen. 1% methylcellulose improved the tissue handling properties of the minced skin. Platelet releasate did not stimulate the migration of skin cells along scaffold fibers. Immunohistochemistry and SEM confirmed the presence of both epithelial and stromal cells in the new tissue. We describe the first key steps in the production of a skin substitute to be assembled in theatre eliminating the need for cell culture. Whilst further experiments are needed to develop this technique it can be a useful addition to armamentarium of the reconstructive surgeon. Copyright © 2013 Elsevier Ltd and ISBI. All rights reserved.

  14. Comparison between mechanical properties of human saphenous vein and umbilical vein

    Directory of Open Access Journals (Sweden)

    Hamedani Borhan

    2012-08-01

    Full Text Available Abstract Background As a main cause of mortality in developed countries, Coronary Artery Disease (CAD is known as silent killer with a considerable cost to be dedicated for its treatment. Coronary Artery Bypass Graft (CABG is a common remedy for CAD for which different blood vessels are used as a detour. There is a lack of knowledge about mechanical properties of human blood vessels used for CABG, and while these properties have a great impact on long-term patency of a CABG. Thus, studying these properties, especially those of human umbilical veins which have not been considered yet, looks utterly necessary. Methods Umbilical vein, as well as human Saphenous vein, are respectively obtained after cesarean and CABG. First, histological tests were performed to investigate different fiber contents of the samples. Having prepared samples carefully, force-displacement results of samples were rendered to real stress–strain measurements and then a fourth-order polynomial was used to prove the non-linear behavior of these two vessels. Results Results were analyzed in two directions, i.e. circumferentially and longitudinally, which then were compared with each other. The comparison between stiffness and elasticity of these veins showed that Saphenous vein’s stiffness is much higher than that of umbilical vein and also, it is less stretchable. Furthermore, for both vessels, longitudinal stiffness was higher than that of circumferential and in stark contrast, stretch ratio in circumferential direction came much higher than longitudinal orientation. Conclusion Blood pressure is very high in the region of aorta, so there should be a stiff blood vessel in this area and previous investigations showed that stiffer vessels would have a better influence on the flow of bypass. To this end, the current study has made an attempt to compare these two blood vessels’ stiffness, finding that Saphenous vein is stiffer than umbilical vein which is somehow as stiff as

  15. Reconstructed anterior cruciate ligaments using patellar tendon ligament grafts: diagnostic value of contrast-enhanced MRI in a 2-year follow-up regimen

    Energy Technology Data Exchange (ETDEWEB)

    Vogl, T.J.; Schmitt, J.; Lubrich, J.; Hochmuth, K.; Diebold, T. [Dept. of Diagnostic and Interventional Radiology, Frankfurt Univ. (Germany); Del Tredici, K. [Dept. of Clinical Neuroanatomy, Frankfurt Univ. (Germany); Suedkamp, N. [Dept. of Traumatology and Orthopedics, Humboldt University, Berlin (Germany)

    2001-08-01

    We analyzed prospectively the diagnostic efficacy of contrast-enhanced MRI following anterior cruciate neoligament (ACL) reconstruction. One hundred fifty-six MR examinations were performed 2, 12, 52, 76, and 104 weeks post-operatively on 68 patients with ACL transplants. Sagittal, parasagittal, and coronal images using unenhanced T1- and T2-weighted spin-echo sequences, and post-contrast images utilizing T1-weighted spin-echo and fat-saturated sequences, were acquired. Results were correlated with those of the pivot shift, Lachman, and a mechanical test. The MR examination criteria included morphological analysis, signal intensity, transplant contrast enhancement, secondary signs (e.g., elongation of normal ligaments), and comparison with clinically standardized test results. Two weeks post-operatively all neoligaments showed homogeneous low signal intensity on T1- and T2-weighted spin-echo sequences indistinguishable from that of normal cruciate or patellar ligaments [contrast-to-noise ratio (C/N) on T1:1.6], with a 9% percentile enhancement. At 12-52 weeks, signal intensity increased (C/N:6.7), with a mean 50% percentile enhancement. The 1-year follow-up allowed no definite assessment of the neoligament's course. At 76 and 104 weeks, significant decrements in signal intensity (C/N:3.0) and ligamentous percentile enhancement (25%) occurred. All patients tested displayed stable transplants 2 years post-operatively. Contrast-enhanced MRI allows accurate evaluation of morphology and function up to 3 months post-operatively and 1-2 years following ACL reconstructive surgery. (orig.)

  16. Reconstruction of hand contracture by reverse ulnar perforator flap

    Directory of Open Access Journals (Sweden)

    Cengiz Eser

    2016-04-01

    Full Text Available Hand burn scar contractures affect patients in aesthetic and functional aspects. After releasing these scars, the defects should be repaired. The reconstruction methods include primary suturation, Z plasty, skin grafting, local or free flaps, etc. All methods have their own advantages and disadvantages. One of the most useful flaps is the reverse ulnar perforator flap. We performed a two-staged procedure for repairing a post-burn contracture release defect in a 40-year-old male. In the first stage we applied reverse ulnar perforator flap for the hand defect, and ulnar artery and vein repair in the second stage. In conclusion, this two-staged procedure is a non-primary but useful option for hand and finger defects and prevents major vascular structure damage of the forearm. [Hand Microsurg 2016; 5(1.000: 40-43

  17. Pelvic Vein Embolisation in the Management of Varicose Veins

    International Nuclear Information System (INIS)

    Ratnam, Lakshmi A.; Marsh, Petra; Holdstock, Judy M.; Harrison, Charmaine S.; Hussain, Fuad F.; Whiteley, Mark S.; Lopez, Anthony

    2008-01-01

    Pelvic vein incompetence is common in patients with atypical varicose veins, contributing to their recurrence after surgery. Therefore, refluxing pelvic veins should be identified and treated. We present our experience with pelvic vein embolisation in patients presenting with varicose veins. Patients presenting with varicose veins with a duplex-proven contribution from perivulval veins undergo transvaginal duplex sonography (TVUS) to identify refluxing pelvic veins. Those with positive scans undergo embolisation before surgical treatment of their lower limb varicose veins. A total of 218 women (mean age of 46.3 years) were treated. Parity was documented in the first 60 patients, of whom 47 (78.3%) were multiparous, 11 (18.3%) had had one previous pregnancy, and 2 (3.3%) were nulliparous. The left ovarian vein was embolised in 78%, the right internal iliac in 64.7%, the left internal iliac in 56.4%, and the right ovarian vein in 42.2% of patients. At follow-up TVUS, mild reflux only was seen in 16, marked persistent reflux in 6, and new reflux in 3 patients. These 9 women underwent successful repeat embolisation. Two patients experienced pulmonary embolisation of the coils, of whom 1 was asymptomatic and 1 was successfully retrieved; 1 patient had a misplaced coil protruding into the common femoral vein; and 1 patient had perineal thrombophlebitis. The results of our study showed that pelvic venous embolisation by way of a transjugular approach is a safe and effective technique in the treatment of pelvic vein reflux.

  18. Reconstrução coracoclavicular com enxerto tendíneo na luxação acromioclavicular crônica Coracoclavicular reconstruction using tendinous graft for chronic acromioclavicular joint dislocation

    Directory of Open Access Journals (Sweden)

    Jorge Henrique Assunção

    2011-01-01

    Full Text Available OBJETIVO: Apresentar os resultados radiográficos e funcionais de pacientes submetidos ao tratamento da luxação acromioclavicular crônica com reconstrução dos ligamentos coracoclaviculares com enxerto de tendão semitendíneo. MÉTODO: Quinze pacientes, entre abril de 2007 e junho de 2008, foram submetidos a reconstrução dos ligamentos coracoclaviculares com enxerto tendíneo. Dois pacientes foram excluídos do estudo por seguimento inadequado. Treze pacientes foram seguidos clinicamente e radiograficamente, em média, por 16 meses (12-26 meses. Os pacientes foram submetidos a avaliação clinica pré e pós-operatória, utilizando os escores Constant e UCLA. Radiografias pré e pós-operatórias foram comparadas. RESULTADOS: Neste grupo de 13 pacientes com seguimento mínimo de um ano, o escore Constant variou de 60,9 (26-88 na avaliação pré-operatória para 87 (60-98 na última avaliação no período pós-operatório. O escore UCLA foi de 16,8 (11-27 no pré operatório para 33 (29-35 na avaliação pós-operatória (p=0,001. No controle radiográfico com um ano de pós-operatório, encontramos 12 pacientes (92% com a distância coracoclavicular igual comparando o ombro operado ao contralateral. Todos os ombros operados apresentavam-se sem translação na direção antero-posterior no perfil axilar. CONCLUSÃO: O resultado funcional e radiográfico foi muito satisfatório nos pacientes submetidos à reconstrução das luxações acromioclaviculares crônicas, com baixo indice de recidiva. Nivel de Evidência IV, série de casos.OBJECTIVE: The aim of this study is to present the radiographic and functional results of patients undergoing treatment for chronic acromioclavicular dislocation with coracoclavicular ligament reconstruction using tendon graft. METHOD: Between 2007 and 2008, fifteen patients with chronic Rockwood type III through V acromioclavicular joint dislocations underwent reconstruction of the coracoclavicular ligaments

  19. Stent graft placement for dysfunctional arteriovenous grafts

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Gyeong Sik [Dept. of Radiology, CHA Bundang Medical Center, College of Medicine, CHA University, Seongnam (Korea, Republic of); Shin, Byung Seok; Ohm, Joon Young; Ahn, Moon Sang [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2015-07-15

    This study aimed to evaluate the usefulness and outcomes of stent graft use in dysfunctional arteriovenous grafts. Eleven patients who underwent stent graft placement for a dysfunctional hemodialysis graft were included in this retrospective study. Expanded polytetrafluoroethylene covered stent grafts were placed at the venous anastomosis site in case of pseudoaneurysm, venous laceration, elastic recoil or residual restenosis despite the repeated angioplasty. The patency of the arteriovenous graft was evaluated using Kaplan-Meier analysis. Primary and secondary mean patency was 363 days and 741 days. Primary patency at 3, 6, and 12 months was 82%, 73%, and 32%, respectively. Secondary patency at the 3, 6, 12, 24, and 36 months was improved to 91%, 82%, 82%, 50%, and 25%, respectively. Fractures of the stent graft were observed in 2 patients, but had no effect on the patency. Stent graft placement in dysfunctional arteriovenous graft is useful and effective in prolonging graft patency.

  20. Portal vein thrombosis.

    Science.gov (United States)

    Chawla, Yogesh K; Bodh, Vijay

    2015-03-01

    Portal vein thrombosis is an important cause of portal hypertension. PVT occurs in association with cirrhosis or as a result of malignant invasion by hepatocellular carcinoma or even in the absence of associated liver disease. With the current research into its genesis, majority now have an underlying prothrombotic state detectable. Endothelial activation and stagnant portal blood flow also contribute to formation of the thrombus. Acute non-cirrhotic PVT, chronic PVT (EHPVO), and portal vein thrombosis in cirrhosis are the three main variants of portal vein thrombosis with varying etiological factors and variability in presentation and management. Procoagulant state should be actively investigated. Anticoagulation is the mainstay of therapy for acute non-cirrhotic PVT, with supporting evidence for its use in cirrhotic population as well. Chronic PVT (EHPVO) on the other hand requires the management of portal hypertension as such and with role for anticoagulation in the setting of underlying prothrombotic state, however data is awaited in those with no underlying prothrombotic states. TIPS and liver transplant may be feasible even in the setting of PVT however proper selection of candidates and type of surgery is warranted. Thrombolysis and thrombectomy have some role. TARE is a new modality for management of HCC with portal vein invasion.

  1. Deep Vein Thrombosis

    Centers for Disease Control (CDC) Podcasts

    2012-04-05

    This podcast discusses the risk for deep vein thrombosis in long-distance travelers and ways to minimize that risk.  Created: 4/5/2012 by National Center for Emerging and Zoonotic Infectious Diseases (NCEZID).   Date Released: 4/5/2012.

  2. [Deep vein thrombosis prophylaxis.

    Science.gov (United States)

    Sandoval-Chagoya, Gloria Alejandra; Laniado-Laborín, Rafael

    2013-01-01

    Background: despite the proven effectiveness of preventive therapy for deep vein thrombosis, a significant proportion of patients at risk for thromboembolism do not receive prophylaxis during hospitalization. Our objective was to determine the adherence to thrombosis prophylaxis guidelines in a general hospital as a quality control strategy. Methods: a random audit of clinical charts was conducted at the Tijuana General Hospital, Baja California, Mexico, to determine the degree of adherence to deep vein thrombosis prophylaxis guidelines. The instrument used was the Caprini's checklist for thrombosis risk assessment in adult patients. Results: the sample included 300 patient charts; 182 (60.7 %) were surgical patients and 118 were medical patients. Forty six patients (15.3 %) received deep vein thrombosis pharmacologic prophylaxis; 27.1 % of medical patients received deep vein thrombosis prophylaxis versus 8.3 % of surgical patients (p < 0.0001). Conclusions: our results show that adherence to DVT prophylaxis at our hospital is extremely low. Only 15.3 % of our patients at risk received treatment, and even patients with very high risk received treatment in less than 25 % of the cases. We have implemented strategies to increase compliance with clinical guidelines.

  3. Using negative pressure therapy for improving skin graft taking on genital area defects following Fournier gangrene.

    Science.gov (United States)

    Orhan, Erkan; Şenen, Dilek

    2017-09-01

    Fournier's gangrene is an infective necrotizing fasciitis of the perineal, genital and perianal regions. Treatment includes aggressive surgical debridement that often results in extensive loss of genital skin. Skin grafts may be used for reconstruction but skin grafting of the male genitalia is diffucult because the penis and scrotum are mobile and deformable. A variety of methods are used to secure skin graft to recipient beds. We used negative pressure therapy (NPT) to secure skin grafts and improve skin graft taking. We used negative pressure therapy for graft fixation in 13 male patients who underwent debridements with the indication of Fournier gangrene, and whose defects formed were reconstructed with grafts between January 2009, and January 2014. Information about age of the patients, sessions of negative pressure therapy applied before, and after reconstruction, duration of hospital stay, and graft losses during postoperative period were recorded. Median age of the patients was 56.15 (46-72) years. NPT was applied to patients for an average of 6.64 sessions (4-12) before and 1 sessions after graft reconstruction. Patients were hospitalized for an average of 26.7 (20-39) days. Any graft loss was not seen after NPT. Because of the peculiar anatomy of the genital region, anchoring of grafts is difficult so graft losses are often encountered. Use of NPT for ensuring graft fixation on the genital region prevents skin graft shearing.

  4. Intraoperative transit-time flow measurement is not altered in venous bypass grafts covered by the eSVS mesh.

    Science.gov (United States)

    Emery, Robert W; Solien, Eric

    2013-01-01

    The aim of this study was to determine whether the eSVS Mesh interferes with transit-time flow measurement (TTFM) assessing intraoperative coronary vein graft patency. In four swine undergoing off-pump bypass grafting to the anterior descending coronary artery, five TTFMs were sequentially obtained on meshed and bare grafts at baseline and under Dobutamine stress at five separate locations on the graft in each animal. The Medistim VeriQ was used for TTFM. The grafts were examined for patency after the swine were killed. There was no difference in hemodynamics or TTFM either at baseline or under Dobutamine stress between the eSVS Mesh covered and uncovered grafts. Dobutamine, however, significantly increased hemodynamics and graft flow parameters measured from baseline. The eSVS Mesh does not interfere with Doppler flow measurement in covered coronary vein grafts.

  5. Evaluation of coronary artery bypass grafts with magnetic resonance imaging

    International Nuclear Information System (INIS)

    Okamura, Yoshitaka; Yamada, Yasuyuki; Mochizuki, Yoshihiko; Iida, Hiroshi; Mori, Hideaki; Sugita, You-ichi; Shimada, Kou-ichirou

    1997-01-01

    Currently, the efficacy of magnetic resonance imaging (MRI) for evaluating coronary artery disease has been reported. In this study, we have evaluated the usefulness and the problems of MRI for evaluating the patency of coronary artery bypass grafts. Thirty-five patients who received coronary artery bypass grafting (CABG) were evaluated by using MRI for determining the graft patency compared with conventional coronary angiography. There were 30 men and 5 women. The mean age was 61.2 years (range 45 to 75). The 35 patients had a total of 92 grafts (28 internal thoracic artery, 7 gastroepiploic artery and 57 saphenous vein grafts). Magnetic resonance coronary angiogram (MRCA) was performed with SIGNA HORIZON 1.5 T (GE Inc.) by using 2D-FASTCARD sequence. All patients underwent imaging in the transverse and coronal planes, most had imaging in the sagittal plane, and a few had in the oblique plane. By using MRCA, 82 of 90 grafts were diagnosed correctly as patent, and 1 of 2 grafts were diagnosed correctly as occluded. Thirty-four of 40 LAD grafts (85%), 20 of 22 RCA grafts (91%) and 29 of 30 Cx grafts (97%) were correctly evaluated. The efficacy of MRCA for evaluating the patency of coronary artery bypass grafts was recognized. But the sternal wire (stainless steel) and hemoclip interfere with the interpretation and reduce the sensitivity. Higher sensitivity may be obtained by changing the material of the sternal wires and hemoclips at coronary surgery. (author)

  6. The caudal septum replacement graft.

    Science.gov (United States)

    Foda, Hossam M T

    2008-01-01

    To describe a technique for reconstructing the lost tip support in cases involving caudal septal and premaxillary deficiencies. The study included 120 patients with aesthetic and functional nasal problems resulting from the loss of caudal septal and premaxillary support. An external rhinoplasty approach was performed to reconstruct the lost support using a cartilaginous caudal septum replacement graft and premaxillary augmentation with Mersilene mesh. The majority of cases (75%) involved revisions in patients who had previously undergone 1 or more nasal surgical procedures. A caudal septum replacement graft was combined with premaxillary augmentation in 93 patients (77.5%). The mean follow-up period was 3 years (range, 1-12 years). The technique succeeded in correcting the external nasal deformities in all patients and resulted in a significant improvement in breathing in 74 patients (86%) with preoperative nasal obstruction. There were no cases of infection, displacement, or extrusion. The caudal septum replacement graft proved to be very effective in restoring the lost tip support in patients with caudal septal deficiency. Combining the graft with premaxillary augmentation using Mersilene mesh helped increase support and stability over long-term follow-up.

  7. Collateral veins in left renal vein stenosis demonstrated via CT

    Energy Technology Data Exchange (ETDEWEB)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-02-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development.

  8. Collateral veins in left renal vein stenosis demonstrated via CT

    International Nuclear Information System (INIS)

    Lien, H.H.; Lund, G.; Talle, K.

    1983-01-01

    Twelve patients with left renal vein stenosis from tumor compression were studied with CT. All had distended collateral veins in the perirenal space which either formed a radiating or a cobweb pattern or appeared as marked longitudinal veins. Inferior phrenic vein branches were seen in seven patients and were considerably enlarged in two. Other major veins possibly taking part in collateral circulation could not be recognized due to obliteration of fat planes. The renal fascia was thickened in eleven patients, probably due to edema. A close study of the perirenal space with CT may give valuable information about collateral development. (orig.)

  9. Concerns and Discomforts of Pregnancy - Varicose Veins

    Science.gov (United States)

    Concerns and Discomforts of Pregnancy - Varicose Veins Varicose veins are enlarged veins you may see on your ... Healthy Roads Media project www. healthyroadsmedia. org English - Concerns and Discomforts of Pregnancy (Varicose Veins) Last reviewed ...

  10. Case Report: Supernumerary right renal vein draining inferior to the ...

    African Journals Online (AJOL)

    With recent increase in renal transplantations, renovascular reconstructions and imaging advances, meticulous knowledge of the normal and variant anatomy of the renal vasculature is important to avoid potential pitfalls. We report a case of an accessory renal vein arising from the right kidney, and draining into the inferior ...

  11. Estudo comparativo da biocompatibilidade da submucosa intestinal porcina e pericárdio bovino usados como enxertos na veia cava de cães Comparative study of the biocompatibility of the porcine intestinal submucosa and bovine pericardium used as grafts in the inferior cava vein of dogs

    Directory of Open Access Journals (Sweden)

    Fernando Hintz Greca

    2005-08-01

    . Stenosis of the vein was observed in 1 dog of A group and in 2 of the B group. RESULTS: Partial thrombosis with collateral circulation was evidenced in 1 dog of the bovine pericardium group. A moderated chronic inflammatory process was evidenced in both groups. Microscopic evaluation, regarding endothelization of the implant, collagen deposition, smooth muscle growth, was similar in both groups. CONCLUSION: SIS proved to be a functional graft patch for possessing local vena cava remodeling and its biocompatibility was similar to bovine pericardium.

  12. PX-18 Protects Human Saphenous Vein Endothelial Cells under Arterial Blood Pressure.

    Science.gov (United States)

    Kupreishvili, Koba; Stooker, Wim; Emmens, Reindert W; Vonk, Alexander B A; Sipkens, Jessica A; van Dijk, Annemieke; Eijsman, Leon; Quax, Paul H; van Hinsbergh, Victor W M; Krijnen, Paul A J; Niessen, Hans W M

    2017-07-01

    Arterial blood pressure-induced shear stress causes endothelial cell apoptosis and inflammation in vein grafts after coronary artery bypass grafting. As the inflammatory protein type IIA secretory phospholipase A 2 (sPLA 2 -IIA) has been shown to progress atherosclerosis, we hypothesized a role for sPLA 2 -IIA herein. The effects of PX-18, an inhibitor of both sPLA 2 -IIA and apoptosis, on residual endothelium and the presence of sPLA 2 -IIA were studied in human saphenous vein segments (n = 6) perfused at arterial blood pressure with autologous blood for 6 hrs. The presence of PX-18 in the perfusion blood induced a significant 20% reduction in endothelial cell loss compared to veins perfused without PX18, coinciding with significantly reduced sPLA 2 -IIA levels in the media of the vein graft wall. In addition, PX-18 significantly attenuated caspase-3 activation in human umbilical vein endothelial cells subjected to shear stress via mechanical stretch independent of sPLA 2 -IIA. In conclusion, PX-18 protects saphenous vein endothelial cells from arterial blood pressure-induced death, possibly also independent of sPLA 2 -IIA inhibition. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Arterial grafts balance survival between incomplete and complete revascularization: a series of 1000 consecutive coronary artery bypass graft patients with 98% arterial grafts.

    Science.gov (United States)

    Kieser, Teresa M; Curran, Helen J; Rose, M Sarah; Norris, Colleen M; Graham, Michelle M

    2014-01-01

    Coronary artery bypass grafting (CABG) with incomplete revascularization (ICR) is thought to decrease survival. We studied the survival of patients with ICR undergoing total arterial grafting. In a consecutive series of all-comer 1000 patients with isolated CABG, operative and midterm survival were assessed for patients undergoing complete versus ICR, with odds ratios and hazard ratios, adjusted for European System for Cardiac Operative Risk Evaluation category, CABG urgency, age, and comorbidities. In this series of 1000 patients with 98% arterial grafts (2922 arterial, 59 vein grafts), 73% of patients with multivessel disease received bilateral internal mammary artery grafts. ICR occurred in 140 patients (14%). Operative mortality was 3.8% overall, 8.6% for patients with ICR, and 3.2% for patients with complete revascularization (P = .008). For operative mortality using multivariable logistic regression, after controlling for European System for Cardiac Operative Risk Evaluation category (P System for Cardiac Operative Risk Evaluation category (P reserved.

  14. Accessory hepatic vein: MR imaging

    International Nuclear Information System (INIS)

    Lee, Chang Hee; Rho, Tack Soo; Cha, Sang Hoon; Park, Cheol Min; Cha, In Ho

    1995-01-01

    To evaluate the MR appearance of the accessory hepatic veins. The study included 87 consecutive patients for whom abdominal MR images were obtained. The subjects who had liver lesion or hepatic vascular abnormalities were excluded. Couinaud classified accessory hepatic veins into inferior and middle right hepatic veins. Our major interests were evaluation of the incidence, morphology, and location of the accessory hepatic vein. Inferior right hepatic vein was demonstrated in 43 out of 87 patients (49%). The morphology was linear in 35 patients (80.5%), and V-shaped in 8 patients (19.5%). In 40 patients (93%), the inferior right hepatic vein was located in the posteroinferior aspect of the right lobe. Middle right hepatic vein was demonstrated in 7 out of 87 patients (8%). All were single linear in morphology, combined with the inferior right hepatic vein, and located between the right hepatic vein and inferior right hepatic vein. The accessory hepatic vein was demonstrated in 49% among the Korean adult population, and was located in posteroinferior portion of the liver, in 93%

  15. Bone Graft Alternatives

    Science.gov (United States)

    ... Spine Treatment Spondylolisthesis BLOG FIND A SPECIALIST Treatments Bone Graft Alternatives Patient Education Committee Patient Education Committee ... procedure such as spinal fusion. What Types of Bone Grafts are There? Bone grafts that are transplanted ...

  16. Dysphagia after Colon Interposition Graft for Esophageal Carcinoma

    Directory of Open Access Journals (Sweden)

    C. Spitali

    2012-01-01

    Full Text Available Colon interposition is an established technique for esophageal reconstruction. We describe the case of primary adenocarcinoma arising in a colonic interposition graft that was performed after total esophagectomy for recurrence adenocarcinoma derived from the Barrett esophagus.

  17. Isolated Subclavian Vein Injury: A Rare and High Mortality Case

    Directory of Open Access Journals (Sweden)

    Sahin Iscan

    2013-01-01

    Full Text Available Isolated subclavian vein injuries are rarely seen without concomitant arterial injury, bone fracture, damage to brachial plexus, and thoracal traumas. Our case was brought to the emergency service 6 hours after he had been shot at the shoulder with a firearm. After detection of extravasation from the left axillary and subclavian vein on arteriographic and venographic examinations, he was operated on. An autogenous saphenous vein graft was interposed between subclavian and axillary veins. Cardiac arrest developed twice because of hypovolemia, which was resolved with medical therapy. Subclavian vein injuries have a more mortal course when compared with the injuries to the subclavian arteries. Its most important reason is excessive blood loss and air embolism because of delayed arrival to hospital. As is the case in all vascular injuries, angiography is the most important diagnostic examination. If the general health state of the patient permits, arteriography and venography should be performed in patients potentially exposed to vascular injuries. In patients with extreme blood loss and deteriorated health state, direct surgical exploration of the injury site, containment of the bleeding, and venous repair are life-saving approaches.

  18. Excellent Aesthetic and Functional Outcome After Fractionated Carbon Dioxide Laser Skin Graft Revision Surgery: Case Report and Review of Laser Skin Graft Revision Techniques.

    Science.gov (United States)

    Ho, Derek; Jagdeo, Jared

    2015-11-01

    Skin grafts are utilized in dermatology to reconstruct a defect secondary to surgery or trauma of the skin. Common indications for skin grafts include surgical removal of cutaneous malignancies, replacement of tissue after burns or lacerations, and hair transplantation in alopecia. Skin grafts may be cosmetically displeasing, functionally limiting, and significantly impact patient's quality-of-life. There is limited published data regarding skin graft revision to enhance aesthetics and function. Here, we present a case demonstrating excellent aesthetic and functional outcome after fractionated carbon dioxide (CO2) laser skin graft revision surgery and review of the medical literature on laser skin graft revision techniques.

  19. Fabrication and preliminary study of a biomimetic tri-layer tubular graft based on fibers and fiber yarns for vascular tissue engineering.

    Science.gov (United States)

    Wu, Tong; Zhang, Jialing; Wang, Yuanfei; Li, Dandan; Sun, Binbin; El-Hamshary, Hany; Yin, Meng; Mo, Xiumei

    2018-01-01

    Designing a biomimetic and functional tissue-engineered vascular graft has been urgently needed for repairing and regenerating defected vascular tissues. Utilizing a multi-layered vascular scaffold is commonly considered an effective way, because multi-layered scaffolds can easily simulate the structure and function of natural blood vessels. Herein, we developed a novel tri-layer tubular graft consisted of Poly(L-lactide-co-caprolactone)/collagen (PLCL/COL) fibers and Poly(lactide-co-glycolide)/silk fibroin (PLGA/SF) yarns via a three-step electrospinning method. The tri-layer vascular graft consisted of PLCL/COL aligned fibers in inner layer, PLGA/SF yarns in middle layer, and PLCL/COL random fibers in outer layer. Each layer possessed tensile mechanical strength and elongation, and the entire tubular structure provided tensile and compressive supports. Furthermore, the human umbilical vein endothelial cells (HUVECs) and smooth muscle cells (SMCs) proliferated well on the materials. Fluorescence staining images demonstrated that the axially aligned PLCL/COL fibers prearranged endothelium morphology in lumen and the circumferential oriented PLGA/SF yarns regulated SMCs organization along the single yarns. The outside PLCL/COL random fibers performed as the fixed layer to hold the entire tubular structure. The in vivo results showed that the tri-layer vascular graft supported cell infiltration, scaffold biodegradation and abundant collagen production after subcutaneous implantation for 10weeks, revealing the optimal biocompatibility and tissue regenerative capability of the tri-layer graft. Therefore, the specially designed tri-layer vascular graft will be beneficial to vascular reconstruction. Copyright © 2017. Published by Elsevier B.V.

  20. Influence of using a single facial vein as outflow in full-face transplantation: A three-dimensional computed tomographic study.

    Science.gov (United States)

    Rodriguez-Lorenzo, Andres; Audolfsson, Thorir; Wong, Corrine; Cheng, Angela; Arbique, Gary; Nowinski, Daniel; Rozen, Shai

    2015-10-01

    The aim of this study was to evaluate the contribution of a single unilateral facial vein in the venous outflow of total-face allograft using three-dimensional computed tomographic imaging techniques to further elucidate the mechanisms of venous complications following total-face transplant. Full-face soft-tissue flaps were harvested from fresh adult human cadavers. A single facial vein was identified and injected distally to the submandibular gland with a radiopaque contrast (barium sulfate/gelatin mixture) in every specimen. Following vascular injections, three-dimensional computed tomographic venographies of the faces were performed. Images were viewed using TeraRecon Software (Teracon, Inc., San Mateo, CA, USA) allowing analysis of the venous anatomy and perfusion in different facial subunits by observing radiopaque filling venous patterns. Three-dimensional computed tomographic venographies demonstrated a venous network with different degrees of perfusion in subunits of the face in relation to the facial vein injection side: 100% of ipsilateral and contralateral forehead units, 100% of ipsilateral and 75% of contralateral periorbital units, 100% of ipsilateral and 25% of contralateral cheek units, 100% of ipsilateral and 75% of contralateral nose units, 100% of ipsilateral and 75% of contralateral upper lip units, 100% of ipsilateral and 25% of contralateral lower lip units, and 50% of ipsilateral and 25% of contralateral chin units. Venographies of the full-face grafts revealed better perfusion in the ipsilateral hemifaces from the facial vein in comparison with the contralateral hemifaces. Reduced perfusion was observed mostly in the contralateral cheek unit and contralateral lower face including the lower lip and chin units. Copyright © 2015 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Ltd. All rights reserved.

  1. Radiographic analysis of pasteurized autologous bone graft

    International Nuclear Information System (INIS)

    Ahmed, Adel Refaat; Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi

    2003-01-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  2. Radiographic analysis of pasteurized autologous bone graft

    Energy Technology Data Exchange (ETDEWEB)

    Ahmed, Adel Refaat [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan); Department of Orthopedic Surgery, Alexandria University, Alexandria (Egypt); Manabe, Jun; Kawaguchi, Noriyoshi; Matsumoto, Seiichi; Matsushita, Yasushi [Department of Orthopedic Surgery, Cancer Institute Hospital, Japanese Foundation for Cancer Research, Kamiikebukuro 1-37-1, Toshima-ku, 170-0012, Tokyo (Japan)

    2003-08-01

    Local malignant bone tumor excision followed by pasteurization and subsequent reimplantation is a unique technique for reconstruction after resection of primary bone sarcomas. The purpose of this investigation was to assess the normal and abnormal long-term radiographic findings of intercalary and osteo-chondral pasteurized bone graft/implant composite. The long-term radiographic findings of pasteurized bone grafts used in reconstruction after resection of bone and soft tissue sarcomas in relation to patients' clinical data were reviewed retrospectively. Thirty-one patients (18 females, 13 males; age range 7-77 years, mean 30 years) who underwent surgery between April 1990 and January 1997 at the authors' institute constituted the material of this study. They were followed up for at least 3 years or until the patient's death (mean 69 months). The International Society of Limb Salvage graft evaluation method that assesses the fusion, resorption, fracture, graft shortening, fixation, subluxation, joint narrowing and subchondral bone was used for evaluation of the radiographs. Twenty-one patients (68%) showed complete incorporation of graft and eight patients (26%) had partial incorporation. The overall radiographic evaluation rate was 81%. Fracture (10%) and infection (16%) were the main complications. No local recurrence was detected. These results indicate that pasteurization of bone is a useful option for reconstruction after resection of malignant bone tumors. (orig.)

  3. Medial sural artery as a salvage recipient vessel for complex post traumatic microvascular lower limb reconstruction.

    Science.gov (United States)

    Baliarsing, Amresh; Date, Shivprasad; Ciudad, Pedro

    2018-02-01

    Complex lower extremity trauma still poses a formidable challenge for micro vascular reconstruction. The extensive surrounding zone of trauma can make it difficult to find a suitable recipient pedicle for anastomosis. A need was felt for exploration of newer recipient vessels in lower extremity which could be harnessed for reliable and tension free micro anastomosis. The purpose of the present report is to highlight the possibility of using medial sural artery for safe micro vascular anastomosis in selected scenarios like vessel depleted extremity. Between 2008 and 2013, we used the medial sural vessels for micro anastomosis in 10 cases of lower extremity trauma. All the cases had severe soft tissue trauma with or without a bony defect. A computed tomography angiogram (CTA) of the involved extremity revealed either severe perivascular scarring around the standard recipient vessels or patency of just a single vessel. However, in all cases a patent medial sural pedicle was identified on CTA. Interposition vein grafts (IVGs) were used in most cases to ensure a tension free anastomosis. In all cases, unscarred medial sural vessels were identified with average dissected length and diameter being 6.2 cm (range 4 to 7.5 cm) and 2 mm (range 1.5 to 2.5 mm) respectively. Vein graft [average length 5.6 cm (range 4 to 15 cm)] was interposed in seven cases, while in remaining three, long saphenous vein was used for vein anastomosis. All the flaps survived after the surgery. There was one re-exploration for evacuation of peri-anastomotic hematoma with no adverse effect on flap survival. The mean follow up period was 27.6 months. In the four cases with bone reconstruction, bony union was seen between 5 and 8 months. They were able to walk without aids and resume work after 10-14 months, following a structured rehabilitation program. The patients with soft tissue reconstruction (6 cases) could carry out aid free locomotion and resume their routine after 4-6 weeks. There were no

  4. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    Directory of Open Access Journals (Sweden)

    Hirpara Kieran M

    2011-07-01

    Full Text Available Abstract Background Tensioning of anterior cruciate ligament (ACL reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  5. Anterior cruciate ligament graft tensioning. Is the maximal sustained one-handed pull technique reproducible?

    LENUS (Irish Health Repository)

    O'Neill, Barry J

    2011-07-20

    Abstract Background Tensioning of anterior cruciate ligament (ACL) reconstruction grafts affects the clinical outcome of the procedure. As yet, no consensus has been reached regarding the optimum initial tension in an ACL graft. Most surgeons rely on the maximal sustained one-handed pull technique for graft tension. We aim to determine if this technique is reproducible from patient to patient. Findings We created a device to simulate ACL reconstruction surgery using Ilizarov components and porcine flexor tendons. Six experienced ACL reconstruction surgeons volunteered to tension porcine grafts using the device to see if they could produce a consistent tension. None of the surgeons involved were able to accurately reproduce graft tension over a series of repeat trials. Conclusions We conclude that the maximal sustained one-handed pull technique of ACL graft tensioning is not reproducible from trial to trial. We also conclude that the initial tension placed on an ACL graft varies from surgeon to surgeon.

  6. Mesh-graft urethroplasty: a case report

    OpenAIRE

    田中, 敏博; 滝川, 浩; 香川, 征; 長江, 浩朗

    1987-01-01

    We used a meshed free-foreskin transplant in a two-stage procedure for reconstruction of the extended stricture of urethra after direct vision urethrotomy. The results were excellent. Mesh-graft urethroplasty is a useful method for patients with extended strictures of the urethra or recurrent strictures after several operations.

  7. [TRANSPORT OF OXYGEN DURING GEOMETRICAL RECONSTRUCTION OF THE LEFT VENTRICLE IN CONJUNCTION WITH CORONARY ARTERY BYPASS GRAFTING AND USING OF HIGH THORACIC EPIDURAL ANESTHESIA AS A MAJOR COMPONENT OF GENERAL ANAESTHESIA].

    Science.gov (United States)

    Zatevahina, M V; Farzutdinov, A F; Rahimov, A A; Makrushin, I M; Kvachantiradze, G Y

    2015-01-01

    The purpose of the study is to examine the perioperative dynamics of strategic blood oxygen transport indicators: delivery (DO2), consumption (VO2), the coefficient of oxygen uptake (CUO2) and their composition, as well as the dynamics of blood lactate indicators in patients with ischaemic heart disease (IHD) who underwent surgery under cardiopulmonary bypass with high thoracic epidural anaesthesia (HTEA) as the main component of anesthesia. Research was conducted in 30 patients with a critical degree of operational risk, during the correction of post-infarction heart aneurysmn using the V. Dor method in combination with coronary artery bypass grafting. The strategic blood oxygen transport indicators (delivery, consumption and the oxygen uptake coefficient) showed a statistically significant decrease compared to the physiological norm and to the initial data at two points of the research: the intubation of the trachea and during cardiopulmonary bypass. The system components of oxygen were influenced at problematic stages by the dynamics of SvO2 (increase), AVD (decrease), hemodilution withe fall of the HIb- in the process of JR in the persence of superficial hypothermia. The maintenance of optimal CA in the context of HTEA, combined with a balanced volemic load and a minimized cardiotonic support ensured the stabilisation of strategic blood oxygen transport indicators aithe postperfusion stage and during the immediate postoperative period The article is dedicated to the study of strategic blood oxygen transport indicators and their components during the operation of geometric reconstruc-tion of the left ventricle combined with coronary artery-bypass using cardiopulmonary bypass and with high thoracic epidural anesthesia as the main component of general anaesthesia. The analysis has covered the stagewise delivery dynamics, consumption and the oxygen uptake coefficient at II stages of the operation and of the immediate postoperative period. The study has ident (fled

  8. Does patency after a vein collar and PTFE-bypass depend on sex and age?

    DEFF Research Database (Denmark)

    Lundgren, F; Schroeder, Torben Veith

    2012-01-01

    Randomized studies evaluating the effect of a vein collar at the distal anastomosis of PTFE-grafts show conflicting results. The study of the Joint Vascular Research Group (JVRG) of UK found improved primary patency while the Scandinavian Miller Collar Study (SCAMICOS) found neither any effect...

  9. Unification venoplasty to cope with recipient portal vein anomaly during living donor liver transplantation.

    Science.gov (United States)

    Kang, S-H; Hwang, S; Jung, D-H; Ahn, C-S; Moon, D-B; Ha, T-Y; Song, G-W; Kim, K-H; Park, G-C; Namgoong, J-M; Park, Y-H; Park, H-W; Jung, B-H; Lee, S-G

    2013-10-01

    To cope with recipient portal vein (PV) anomalies, such as early branching of the right posterior section (RPS), during living donor liver transplantation (LDLT) surgery, we performed a simulation study to standardize the surgical technique for unification portal venoplasty. This study included an observational analysis of conventional methods utilizing RPS PV, simulation-based design of a new surgical technique, and clinical application of this new technique. In a case encountering RPS PV, a mild anastomotic PV stenosis was persistent over 6 months postsurgery, indicating the need for technical refinement. After computational simulation analysis, we found that simple suturing of the PV branch patch automatically resulted in a funnel-shaped elongation. A prospective recipient study (n = 30) indicated that usual PV reconstruction via the PV bifurcation method is feasible in the absence of unusual donor or recipient PV anomaly. Retrospective living donor PV anatomy analysis (n = 20) revealed that 20-mm-long limbs of the first-order PV branches are necessary to make a 10- to l5-mm-long funneled PV stump. This technique of unification venoplasty for an anomalous recipient PV was applied to an adult patient undergoing LDLT with a right liver graft, for which it was shown to be technically feasible and effective. A simplified unification venoplasty technique was developed to cope with a recipient PV anomaly in adult LDLT. Copyright © 2013. Published by Elsevier Inc.

  10. Versatility of radial forearm free flap for intraoral reconstruction

    Directory of Open Access Journals (Sweden)

    Jeremić Jelena V.

    2015-01-01

    Full Text Available Introduction. The radial forearm free flap has an important role in reconstruction of the oncologic defects in the region of head and neck. Objective. The aim was to present and evaluate clinical experience and results in the radial forearm free transfer for intraoral reconstructions after resections due to malignancies. Methods. This article illustrates the versatility and reliability of forearm single donor site in 21 patients with a variety of intraoral oncologic defects who underwent immediate (19 patients, 90.5% or delayed (2 patients, 9.5% reconstruction using free flaps from the radial forearm. Fascio-cutaneous flaps were used in patients with floor of the mouth (6 cases, buccal mucosa (5 cases, lip (1 case and a retromolar triangle (2 cases defects, or after hemiglossectomy (7 cases. In addition, the palmaris longus tendon was included with the flap in 2 patients that required oral sphincter reconstruction. Results. An overall success rate was 90.5%. Flap failures were detected in two (9.5% patients, in one patient due to late ischemic necrosis, which appeared one week after the surgery, and in another patient due to venous congestion, which could not be salvaged after immediate re-exploration. Two patients required re-exploration due to vein thrombosis. The donor site healed uneventfully in all patients, except one, who had partial loss of skin graft. Conclusion. The radial forearm free flap is, due to multiple advantages, an acceptable method for reconstructions after resection of intraoral malignancies. [Projekat Ministarstva nauke Republike Srbije, br. 41006

  11. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    International Nuclear Information System (INIS)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients with

  12. Successful surgical repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery with prior reconstruction of the carotid artery

    Energy Technology Data Exchange (ETDEWEB)

    Miyahara, Ken; Maeda, Masanobu; Sakai, Yoshimasa; Sakurai, Hajime; Murayama, Hiroomi; Hasegawa, Hiroki [Social Insurance Chukyo Hospital, Nagoya (Japan)

    2003-01-01

    We report the successful repair of impending rupture of a pseudoaneurysm of the brachiocephalic artery (BCA) in a 70-year-old man. He had undergone a mediastinal tumor resection through a median sternotomy in 1995. Pathological examination revealed non-Hodgkin's lymphoma. Two years later, he underwent radiation therapy of 65 Gray for metastasis to the supraclavicular lymph nodes. On January 18, 2000, plastic surgeons planned to perform a pectoralis major musculocutaneous flap to repair a radiation skin ulcer. During the operation, the BCA was lacerated, possibly in an area of radiation tissue damage. We performed a prosthetic graft (10-mm Gelseal) replacement of the BCA. The right subclavian artery had to be ligated. Postoperative digital subtraction angiography (DSA) showed excellent reconstruction of the artery. Magnetic resonance angiography of the brain showed a deficit in the anterior communicating artery and stenosis of the posterior communicating artery, which indicated that the reconstruction procedure was reasonable. Seven months later, on August 18, 2000, the patient was transferred to our hospital because of swelling of the right neck and oozing from the previous cutaneous wound. CT scan and DSA demonstrated the presence of a pseudoaneurysm of the proximal anastomosis site, which required emergency surgery. Before this third sternotomy, a saphenous vein graft was interposed between both external carotid arteries. Removal of the prosthetic graft and resection of the pseudoaneurysm were performed under mild hypothermia and cardiopulmonary bypass with left common carotid arterial perfusion. Then, the wound was closed completely using a left pectoralis major musculocutaneous flap. The postoperative course was uneventful and DSA showed good patency of the graft and intracranial arteries. The patient was discharged without neurological complications. We conclude that prior reconstruction of the carotid artery is a safe and effective procedure for patients

  13. Novel anterior cruciate ligament graft fixation device reduces slippage

    Directory of Open Access Journals (Sweden)

    Lopez MJ

    2013-05-01

    Full Text Available Mandi J Lopez,1 Allen Borne,2 W Todd Monroe,3 Prakash Bommala,1 Laura Kelly,1 Nan Zhang11Laboratory for Equine and Comparative Orthopedic Research, Department of Veterinary Clinical Sciences, School of Veterinary Medicine, Louisiana State University, Baton Rouge, 2Louisiana State University, New Orleans Health Sciences Center, School of Medicine, New Orleans, 3Department of Biological and Agricultural Engineering, Agricultural Center, Louisiana State University, Baton Rouge, LA, USAAbstract: Clinically significant laxity occurs in 10%–30% of knees after anterior cruciate ligament reconstruction. Graft slippage and tension loss at the hamstring graft tibial fixation site during and after reconstruction surgery contribute to postoperative joint laxity and are detrimental to long-term knee stability and graft properties. Limiting graft slippage will reduce associated complications. We sought to compare the in vitro mechanical properties and in vivo joint stabilization, postoperative limb use, and graft incorporation of the novel GraftGrab™ (GG device designed to reduce hamstring graft tibial fixation slippage with the commercially available bioabsorbable Bio-Post™ and spiked washer (BP. Mechanical testing was performed on canine tibia-hamstring graft constructs to quantify initial fixation properties. In vivo joint stabilization, postoperative limb use and graft incorporation of hamstring graft reconstructions were determined in a canine model. Outcomes included tibial translation and ground reaction forces preoperatively and 4 and 8 weeks postoperatively, three-dimensional graft and bone tunnel dimensions at the latter two time points, and graft-bone microstructure, as well as mechanical properties 8 weeks after implantation. Immediately after fixation, all grafts slipped from the BP constructs versus about 30% of GG constructs. In vivo limb use remained low, and tibial translation increased with time in the BP cohort. These results together

  14. Tracheal transplantation for carinal reconstruction in dogs.

    Science.gov (United States)

    Kawahara, K; Inutsuka, K; Hiratsuka, M; Makihata, S; Okabayashi, K; Shiraishi, T; Shirakusa, T

    1998-09-01

    Experimental carinal allotransplantation has been performed with tracheocarinal Y-shaped allografts in dogs. In this study we tried canine carinal reconstruction with cylindrical allografts. Carinal reconstruction was performed with allotransplantation of cylindrical trachea in dogs, and graft healing was evaluated by bronchoscopic observation, mucosal blood flow measurement, and histologic examination. A section of the recipient carina containing five tracheal rings and two main stem bronchi was removed, and a donor trachea seven rings long was inserted between the recipient trachea and the left main stem bronchus; then side-to-end anastomosis was performed between the graft midportion and recipient right main stem bronchus (new carina). The grafts were wrapped with pedicled omentum. Fresh grafts were transplanted into one group of dogs (n=8 ), and grafts cryopreserved for 1 week were transplanted into another group (n=7). No anastomotic leakage occurred in any dog. Excellent healing of grafts and graft anastomoses was observed by fiberoptic bronchoscopy in six dogs (75%) in the fresh graft group and in four dogs (57%) in the cryopreserved graft group. The mucosal blood flow in the new carina decreased remarkably and, although it recovered, mucosal blood flow remained under the preoperative level on day 28 after the operation. Cylindrical tracheal allotransplantation is useful for carinal reconstruction, and the method of side-to-end anastomosis between the donor trachea and recipient bronchus is a feasible and accessible procedure in dogs.

  15. CMR diagnosis of coronary graft fistula

    Directory of Open Access Journals (Sweden)

    Bengt Johansson

    2014-01-01

    Full Text Available The patient is a 54-year old man with a previous history of cerebral aqueduct stenosis and hydrocephalus resulting in malignant hypertension who had surgery for permanent ventriculo-peritoneal shunt. At age 41, he had coronary artery bypass graft (CABG surgery with the right internal mammary artery anastomosed to the posterior descending artery and a saphenous vein graft to the first obtuse marginal branch. The patient was recently admitted with pneumonia that rapidly deteriorated and he went in respiratory failure requiring mechanical ventilation. A thoracic CT investigation showed massive bilateral pulmonary infiltrates, pulmonary artery embolism and a large vein graft aneurysm with a maximal diameter of 40 mm (Figure 1 A-B. The management course was complicated with prolonged respiratory failure, persistent infection, despite negative cultures and extended hospital stay. After 50 days of slow recovery the patient was discharged with a need for home oxygen therapy. Ten days later, he was re-admitted with chest pain requiring admission to the coronary care unit where severe pulmonary hypertension was diagnosed with Doppler echocardiography. Troponin-T was mildly elevated, 1,3 ug/L (ref <0,01, CRP was 50 mg/L and chest X-ray showed bilateral lung infiltrates and wide pulmonary vessels. At this point a systo-diastolic murmur was heard at the left lower sternal edge. With a view of potential coronary reintervention and to evaluate the pulmonary hypertension, a coronary angiogram and a pulmonary artery cathetherisation were performed. This showed a new stenosis in the left anterior descending coronary artery and the pulmonary catheterisation showed a “step-up” in oxygen saturation in the pulmonary artery, suggesting a left-to-right shunt. The vein graft aneurysm did not contribute to the coronary circulation. A cardiovascular magnetic resonance scan revealed a communication between the vein graft aneurysm and the left branch pulmonary artery

  16. Bone grafting: An overview

    Directory of Open Access Journals (Sweden)

    D. O. Joshi

    2010-08-01

    Full Text Available Bone grafting is the process by which bone is transferred from a source (donor to site (recipient. Due to trauma from accidents by speedy vehicles, falling down from height or gunshot injury particularly in human being, acquired or developmental diseases like rickets, congenital defects like abnormal bone development, wearing out because of age and overuse; lead to bone loss and to replace the loss we need the bone grafting. Osteogenesis, osteoinduction, osteoconduction, mechanical supports are the four basic mechanisms of bone graft. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. An ideal bone graft material is biologically inert, source of osteogenic, act as a mechanical support, readily available, easily adaptable in terms of size, shape, length and replaced by the host bone. Except blood, bone is grafted with greater frequency. Bone graft indicated for variety of orthopedic abnormalities, comminuted fractures, delayed unions, non-unions, arthrodesis and osteomyelitis. Bone graft can be harvested from the iliac crest, proximal tibia, proximal humerus, proximal femur, ribs and sternum. By adopting different procedure of graft preservation its antigenicity can be minimized. The concept of bone banking for obtaining bone grafts and implants is very useful for clinical application. Absolute stability require for successful incorporation. Ideal bone graft must possess osteogenic, osteoinductive and osteocon-ductive properties. Cancellous bone graft is superior to cortical bone graft. Usually autologous cancellous bone graft are used as fresh grafts where as allografts are employed as an alloimplant. None of the available type of bone grafts possesses all these properties therefore, a single type of graft cannot be recomm-ended for all types of orthopedic abnormalities. Bone grafts and implants can be selected as per clinical problems, the equipments available and preference of

  17. Leiomyosarcoma of the renal vein

    Directory of Open Access Journals (Sweden)

    Lemos Gustavo C.

    2003-01-01

    Full Text Available Leiomyosarcoma of the renal vein is a rare tumor of complex diagnosis. We presented a case of renal vein leiomyosarcoma detected in a routine study. The primary treatment was complete surgical removal of the mass. In cases where surgical removal is not possible the prognosis is poor, with high rates of local recurrence and distant spread.

  18. Midterm Experience of Ipsilateral Axillary-Axillary Arteriovenous Loop Graft as Tertiary Access for Haemodialysis

    Directory of Open Access Journals (Sweden)

    J. P. Hunter

    2014-01-01

    Full Text Available Objectives. To present a series of ipsilateral axillary artery to axillary vein loop arm grafts as an alternative vascular access procedure for haemodialysis in patients with difficult access. Design. Retrospective case series. Methods. Patients who underwent an axillary loop arteriovenous graft from September 2009 to September 2012 were included. Preoperative venous imaging to exclude central venous stenosis and to image arm/axillary veins was performed. A cuffed PTFE graft was anastomosed to the distal axillary artery and axillary vein and looped on the arm. Results. 25 procedures were performed on 22 patients. Median age was 51 years, with 9 males and 13 females. Median number of previous access procedures was 3 (range 0–7. Median followup was 16.4 months (range 1–35. At 3 months and 1 year, the primary and secondary patency rates were 70% and 72% and 36% and 37%, respectively. There were 11 radiological interventions in 6 grafts including 5 angioplasties and 6 thrombectomies. There were 19 surgical procedures in 10 grafts, including thrombectomy, revision, repair for bleeding, and excision. Conclusions. Our series demonstrates that the axillary loop arm graft yields acceptable early patency rates in a complex group of patients but to maintain graft patency required high rates of surgical and radiological intervention, in particular graft thrombectomy.

  19. Vein type uranium deposits

    International Nuclear Information System (INIS)

    1986-01-01

    Veins are tabular- or sheet-like masses of minerals occupying or following a fracture or a set of fractures in the enclosing rock. They have been formed later than the country rock and fractures, either by filling of the open spaces or by partial or complete replacement of the adjoining rock or most commonly by both of these processes combined. This volume begins with the occurrences and deposits known from old shield areas and the sedimentary belts surrounding them. They are followed by papers describing the European deposits mostly of Variscan age, and by similar deposits known from China being of Jurassic age. The volume is completed by two papers which do not fit exactly in the given scheme. A separate abstract was prepared for each of the 25 papers in this report

  20. The economics of vein disease.

    Science.gov (United States)

    Sales, Clifford M; Podnos, Joan; Levison, Jonathan

    2007-09-01

    The management of cosmetic vein problems requires a very different approach than that for the majority of most other vascular disorders that occur in a vascular surgery practice. This article focuses on the business aspects of a cosmetic vein practice, with particular attention to the uniqueness of these issues. Managing patient expectations is critical to the success of a cosmetic vein practice. Maneuvering within the insurance can be difficult and frustrating for both the patient and the practice. Practices should use cost accounting principles to evaluate the success of their vein work. Vein surgery--especially if performed within the office--can undergo an accurate break-even analysis to determine its profitability.

  1. Implantation of Right Kidneys: Is the Risk of Technical Graft Loss Real?

    Science.gov (United States)

    Khan, Taqi T; Ahmad, Nadeem; Siddique, Kashif; Fourtounas, Konstantinos

    2018-05-01

    The left kidney (LK) is preferred by transplant surgeons, because its vein is always of good length and has a thick wall that enables safe suturing. On the other hand, the right renal vein is generally shorter and thinner walled, and well known for its technical difficulty during venous anastomosis, and can result in graft loss. We examined our living (LD) and deceased donor (DD) recipient data and compared the incidence of technical graft loss and early graft function in right and left kidneys. A cohort of 58 adult and pediatric recipients received an LD or DD kidney between January 2015 and December 2016. The donor and recipient data were retrieved and retrospectively analyzed. Technical graft loss was defined as graft thrombosis within the 7 days after transplant. Right kidneys (RKs) were not a risk factor for technical graft loss, and no graft was lost for technical reasons in either LD or DD transplants. Early graft function in LK and RKs was also comparable in the LD cohort, and there were no LKs in the DD cohort. Based on our data, the use of RKs was not a risk factor for technical graft loss and early graft function was comparable to LKs.

  2. Straight configuration saphenous vein transposition to popliteal artery for vascular access.

    Science.gov (United States)

    Caco, Gentian; Golemi, Dhurata; Likaj, Eriola

    2017-03-21

    The saphenous vein is commonly used as a vascular graft in peripheral artery surgery but rarely used for vascular access. The literature on straight configuration saphenous vein transposition to the popliteal artery is scarce. Here we present two cases of straight configuration saphenous vein transposition to the popliteal artery for vascular access, the surgical technique and respective follow-up. Two young men, aged 29 and 36 years, were chosen for lower-limb vascular access for hemodialysis. The first patient was paraplegic since birth. He used his arms to move so upper extremity vascular access was avoided. The second patient presented with an infected upper extremity arteriovenous graft (AVG) and after multiple closed AVFs he had no more available arm veins. Both patients received autologous lower extremity straight configuration saphenous vein transpositions to the popliteal artery under spinal anesthesia in May and October 2012, respectively. Cannulation of the fistula was allowed after one month. There were no early complications. Slight swelling on the leg appeared in one of the patients. Both fistulas were still functional after 36 and 32 months, respectively. The straight configuration saphenous vein transposition to popliteal artery is simple to perform, offers a long and straight segment for cannulation and may be a suitable autologous vascular access in selected patients.

  3. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections.

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2016-12-01

    There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012-2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3 ± 8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. © The Author(s) 2016.

  4. Bio-absorbable antibiotic impregnated beads for the treatment of prosthetic vascular graft infections

    Science.gov (United States)

    Genovese, Elizabeth A; Avgerinos, Efthymios D; Baril, Donald T; Makaroun, Michel S; Chaer, Rabih A

    2017-01-01

    Objective There is limited investigation into the use of bio-absorbable antibiotic beads for the treatment of prosthetic vascular graft infections. Our goal was to investigate the rates of infection eradication, graft preservation, and limb salvage in patients who are not candidates for graft explant or extensive reconstruction. Methods A retrospective review of patients implanted with antibiotic impregnated bio-absorbable calcium sulfate beads at a major university center was conducted. Results Six patients with prosthetic graft infections were treated with bio-absorbable antibiotics beads from 2012–2014. Grafts included an aortobifemoral, an aorto-hepatic/superior mesenteric artery, and four extra-anatomic bypasses. Pathogens included Gram-positive and Gram-negative bacteria. Half of the patients underwent graft explant with reconstruction and half debridement of the original graft, all with antibiotic bead placement around the graft. Mean follow-up was 7.3±8.3 months; all patients had infection resolution, healed wounds, and 100% graft patency, limb salvage, and survival. Conclusion This report details the successful use of bio-absorbable antibiotic beads for the treatment prosthetic vascular graft infections in patients at high risk for graft explant or major vascular reconstruction. At early follow-up, we demonstrate successful infection suppression, graft preservation, and limb salvage with the use of these beads in a subset of vascular patients. PMID:26896286

  5. Subclavian vein aneurysm secondary to a benign vessel wall hamartoma

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Patrick [Nationwide Children' s Hospital, Section of Pediatric Interventional Radiology, Columbus, OH (United States); Spaeth, Maya [Nationwide Children' s Hospital, Section of Plastic and Reconstructive Surgery, Columbus, OH (United States); Prasad, Vinay [Nationwide Children' s Hospital, Section of Pediatric Pathology, Columbus, OH (United States); McConnell, Patrick [Nationwide Children' s Hospital, Section of Cardiothoracic Surgery, Columbus, OH (United States)

    2013-11-15

    Venous aneurysms are rare clinical entities, particularly in children, and their presentation and natural history often depend on the anatomical location and underlying etiology. We present a single case of a 12-year-old girl who presented with a palpable right supraclavicular mass. Imaging evaluation with CT, conventional venography, MRI and sonography revealed a large fusiform subclavian vein aneurysm with an unusual, mass-like fibrofatty component incorporated into the vessel wall. The girl ultimately required complete resection of the right subclavian vein with placement of a synthetic interposition graft. This case provides a radiology/pathology correlation of an entity that has not previously been described as well as an example of the utility of multiple imaging modalities to aid diagnosis and preoperative planning. (orig.)

  6. Evaluation of fluency stent-grafts in transjugular intrahepatic portosystemic shunts

    International Nuclear Information System (INIS)

    Zhao Jianbo; Li Yanhao; Chen Yong; He Xiaofeng; Zeng Qingle; Mei Quelin; Lu Wei

    2009-01-01

    Objective: To evaluate the efficacy of Fluency stent-graft (Bard Corp) in transjugular intrahepatic portosystemic shunt (TIPS). Methods: The clinical data of 21 consecutive patients treated by TIPS using Fluency stent-grafts were retrospectively reviewed. All of them were recurrent variceal bleeding secondary to portal vein hypertension, 1 was bleeding secondary to primary hepatic carcinoma with port vein thrombus, and 1 was Budd-Chiari syndrome. They were followed-up after (10.1±4.6) months (2.0 to 24.0 months). Stent-grafts patancy, portal vein pressure and liver function were recorded and compared. Results: Twenty-five stent-grafts were successfully implanted in 21 patients, 23 stent grafts were 8 mm 2 were 10 mm in diameter. The covered length of the stents varied from 6 to 8 cm. The bleeding was stopped and the portal vein pressure decreased significantly from (25.4±3.5) mm Hg to (15.4±2.8) mm Hg (t= 12.495, P 0.05). Conclusion: The Fluency stent-grafts could increase the patency of the TIPS, but its efficacy on the long-term effect and hepatic encephalopathy need further investigation. (authors)

  7. Nature or Artifice? Grafting in Early Modern Surgery and Agronomy.

    Science.gov (United States)

    Savoia, Paolo

    2017-01-01

    In 1597, Gaspare Tagliacozzi published a famous two-volume book on “plastic surgery.” The reconstructive technique he described was based on grafting skin taken from the arm onto the mutilated parts of the patient's damaged face – especially noses. This paper focuses on techniques of grafting, the “culture of grafting,” and the relationships between surgery and plant sciences in the sixteenth century. By describing the fascination with grafting in surgery, natural history, gardening, and agronomy the paper argues that grafting techniques were subject to delicate issues: to what extent it was morally acceptable to deceive the eye with artificial entities? and what was the status of the product of a surgical procedure that challenged the traditional natural/artificial distinction? Finally, this paper shows how in the seventeenth century grafting survived the crisis of Galenism by discussing the role it played in teratology and in controversies on the uses the new mechanistic anatomy.

  8. An update-tissue engineered nerve grafts for the repair of peripheral nerve injuries.

    Science.gov (United States)

    Patel, Nitesh P; Lyon, Kristopher A; Huang, Jason H

    2018-05-01

    Peripheral nerve injuries (PNI) are caused by a range of etiologies and result in a broad spectrum of disability. While nerve autografts are the current gold standard for the reconstruction of extensive nerve damage, the limited supply of autologous nerve and complications associated with harvesting nerve from a second surgical site has driven groups from multiple disciplines, including biomedical engineering, neurosurgery, plastic surgery, and orthopedic surgery, to develop a suitable or superior alternative to autografting. Over the last couple of decades, various types of scaffolds, such as acellular nerve grafts (ANGs), nerve guidance conduits, and non-nervous tissues, have been filled with Schwann cells, stem cells, and/or neurotrophic factors to develop tissue engineered nerve grafts (TENGs). Although these have shown promising effects on peripheral nerve regeneration in experimental models, the autograft has remained the gold standard for large nerve gaps. This review provides a discussion of recent advances in the development of TENGs and their efficacy in experimental models. Specifically, TENGs have been enhanced via incorporation of genetically engineered cells, methods to improve stem cell survival and differentiation, optimized delivery of neurotrophic factors via drug delivery systems (DDS), co-administration of platelet-rich plasma (PRP), and pretreatment with chondroitinase ABC (Ch-ABC). Other notable advancements include conduits that have been bioengineered to mimic native nerve structure via cell-derived extracellular matrix (ECM) deposition, and the development of transplantable living nervous tissue constructs from rat and human dorsal root ganglia (DRG) neurons. Grafts composed of non-nervous tissues, such as vein, artery, and muscle, will be briefly discussed.

  9. Pattern of venous collateral development after splenic vein occlusion in an extended Whipple procedure : comparison with collateral vein pattern in cases of sinistral portal hypertension.

    Science.gov (United States)

    Strasberg, Steven M; Bhalla, Sanjeev; Sanchez, Luis A; Linehan, David C

    2011-11-01

    The risks of developing sinistral portal hypertension as a result of occlusion of the splenic vein close to its termination during a Whipple procedure are unclear. Our purpose was to compare the pattern of venous collateral development after splenic vein ligation in an extended Whipple procedure with the pattern of collateral development in cases of sinistral portal hypertension. Five patients underwent an extended Whipple procedure in which the splenic vein was divided and not reconstructed. Six to eight months later detailed mapping of venous return from the spleen was determined by contrast-enhanced multidetector computed tomography or in one case by 3D contrast-enhanced MRI. Spleen size and length of residual patent splenic vein were also measured. The literature on sinistral portal hypertension was evaluated to ascertain whether the venous collateral pattern in cases of left-sided portal hypertension was similar to the pattern that developed when the splenic vein was ligated at its termination in the Whipple procedure. A length of splenic vein remained patent in all five patients, measuring 4.5 to 11.5 cm from the spleen. Splenomegaly did not develop. Blood returned from the spleen by multiple collaterals including collaterals in the omentum and mesocolon. These types of collaterals do not develop in sinistral portal hypertension, nor is residual patent splenic vein seen. Ligation of the splenic vein close to its termination in five patients resulted in a pattern of venous return different from patients that have developed left-sided portal hypertension.

  10. Hypothenar hammer syndrome: long-term follow-up after ulnar artery reconstruction with the lateral circumflex femoral artery.

    Science.gov (United States)

    de Niet, A; Van Uchelen, J H

    2017-06-01

    In symptomatic patients with hypothenar hammer syndrome, the occluded part of the ulnar artery can be reconstructed with an autologous graft. Venous grafts are used frequently, but they are known for their low patency rate. Arterial grafts show better patency rates than venous grafts in coronary bypass surgery. We performed 11 ulnar artery reconstructions with the descending branch of the lateral circumflex femoral artery and compared these with previously performed venous reconstructions. All patients with an arterial graft reconstruction had a patent graft at a mean follow-up of 63 months. In addition, nine out of 11 patients reported improvement in their symptoms. The patency rate of venous reconstructions in hypothenar hammer syndrome is significantly lower. Arterial grafting for hypothenar hammer syndrome has superior patency compared with venous grafting; we recommend it as the surgical treatment of choice for symptomatic hypothenar hammer syndrome. 4.

  11. Varicose Vein Treatment (Endovenous Ablation of Varicose Veins)

    Science.gov (United States)

    ... associated veins. top of page What are the benefits vs. risks? Benefits No surgical incision is needed—only a small ... risk of infection. The chance of infection requiring antibiotic treatment appears to be less than one in ...

  12. Vein matching using artificial neural network in vein authentication systems

    Science.gov (United States)

    Noori Hoshyar, Azadeh; Sulaiman, Riza

    2011-10-01

    Personal identification technology as security systems is developing rapidly. Traditional authentication modes like key; password; card are not safe enough because they could be stolen or easily forgotten. Biometric as developed technology has been applied to a wide range of systems. According to different researchers, vein biometric is a good candidate among other biometric traits such as fingerprint, hand geometry, voice, DNA and etc for authentication systems. Vein authentication systems can be designed by different methodologies. All the methodologies consist of matching stage which is too important for final verification of the system. Neural Network is an effective methodology for matching and recognizing individuals in authentication systems. Therefore, this paper explains and implements the Neural Network methodology for finger vein authentication system. Neural Network is trained in Matlab to match the vein features of authentication system. The Network simulation shows the quality of matching as 95% which is a good performance for authentication system matching.

  13. Thrombosis of right ovarian vein

    International Nuclear Information System (INIS)

    Forner, J.; Talens, A.; Flores, M.; Mendez, M.

    2001-01-01

    Ovarian vein thrombosis is a rare postpartum complication (0.1%). It can be fatal, since it can lead to sepsis, pulmonary thromboembolisms and inferior vena cava or renal vein thrombosis. Computed tomography and magnetic resonance imaging are the techniques of choice for its diagnosis, while the value of ultrasound is limited due to its low sensitivity and specificity. We report the case of a woman who, during puerperium, developed thrombosis of right ovarian vein that presented clinical, ultrasonographic and computed tomographic features of appendicitis. We describe the radiological sings and stress the fact that this diagnosis should be suspected in puerperal women. (Author) 9 refs

  14. Grafting and curing

    International Nuclear Information System (INIS)

    Garnett, J.L.; Loo-Teck Ng; Visay Viengkhou

    1998-01-01

    Progress in radiation grafting and curing is briefly reviewed. The two processes are shown to be mechanistically related. The parameters influencing yields are examined particularly for grafting. For ionising radiation grafting systems (EB and gamma ray) these include solvents, substrate and monomer structure, dose and dose-rate, temperature and more recently role of additives. In addition, for UV grafting, the significance of photoinitiators is discussed. Current applications of radiation grafting and curing are outlined. The recent development of photoinitiator free grafting and curing is examined as well as the potential for the new excimer laser sources. The future application of both grafting and curing is considered, especially the significance of the occurrence of concurrent grafting during cure and its relevance in environmental considerations

  15. Skin graft - slideshow

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/presentations/100100.htm Skin graft - series—Normal anatomy To use the sharing features ... entire body, and acts as a protective barrier. Skin grafts may be recommended for: Extensive wounds Burns Specific ...

  16. Bone grafts in dentistry

    Directory of Open Access Journals (Sweden)

    Prasanna Kumar

    2013-01-01

    Full Text Available Bone grafts are used as a filler and scaffold to facilitate bone formation and promote wound healing. These grafts are bioresorbable and have no antigen-antibody reaction. These bone grafts act as a mineral reservoir which induces new bone formation.

  17. PRFM enhance wound healing process in skin graft.

    Science.gov (United States)

    Reksodiputro, Mirta; Widodo, Dini; Bashiruddin, Jenny; Siregar, Nurjati; Malik, Safarina

    2014-12-01

    Facial plastic and reconstructive surgery often used skin graft on defects that cannot be covered primarily by a local flap. However, wound healing using skin graft is slow, most of the time the graft is contractured and the take of graft is not optimal. Platelet rich fibrin matrix (PRFM) is a new generation of concentrated platelets that produce natural fibrin and reported to speed up the healing process. Application of PRFM in the skin graft implants is expected to increase the survival of the graft. We used porcine as animal models to elucidate the effect of autologous PRFM on wound healing in full-thickness (FTSG) and split-thickness (STSG) skin grafts. Survival level of the skin graft was determined by using ImageJ software based on the formation of collagen type 1 and graft take. We observed that the use of PRFM in FTSG and STSG increased type 1 collagen formation. We also found that PRFM addition in STSG gave the best skin graft take. Thieme Medical Publishers 333 Seventh Avenue, New York, NY 10001, USA.

  18. A Vein Map Biometric System

    Directory of Open Access Journals (Sweden)

    Felix Fuentes

    2013-08-01

    Full Text Available There is increasing demand world-wide, from government agencies and the private sector for cutting-edge biometric security technology that is difficult to breach but userfriendly at the same time. Some of the older tools, such as fingerprint, retina and iris scanning, and facial recognition software have all been found to have flaws and often viewed negatively because of many cultural and hygienic issues associated with them. Comparatively, mapping veins as a human barcode, a new technology, has many advantages over older technologies. Specifically, reproducing a three-dimensional model of a human vein system is impossible to replicate. Vein map technology is distinctive because of its state-of-the-art sensors are only able to recognize vein patterns if hemoglobin is actively flowing through the person

  19. Incidence of Central Vein Stenosis and Occlusion Following Upper Extremity PICC and Port Placement

    International Nuclear Information System (INIS)

    Gonsalves, Carin F.; Eschelman, David J.; Sullivan, Kevin L.; DuBois, Nancy; Bonn, Joseph

    2003-01-01

    .Patients with longer catheter dwell time were more likely to develop central vein abnormalities. In order to preserve vascular access for dialysis fistulae and grafts and adhere to Dialysis Outcomes Quality Initiative guidelines, alternative venous access sites should be considered for patients with chronic renal insufficiency and end-stage renal disease

  20. Percutaneous Selective Embolectomy using a Fogarty Thru-Lumen Catheter for Pancreas Graft Thrombosis: A Case Report

    International Nuclear Information System (INIS)

    Izaki, Kenta; Yamaguchi, Masato; Matsumoto, Ippei; Shinzeki, Makoto; Ku, Yonson; Sugimura, Kazuro; Sugimoto, Koji

    2011-01-01

    A 57-year-old woman with a history of diabetes mellitus underwent simultaneous pancreas–kidney transplantation. The pancreaticoduodenal graft was implanted in the right iliac fossa. The donor’s portal vein was anastomosed to the recipient’s inferior vena cava (IVC). Seven days after the surgery, a thrombus was detected in the graft veins. Percutaneous thrombolysis was immediately performed; however, venous congestion was still present. We therefore attempted selective embolectomy using a Fogarty Thru-Lumen Catheter. Thrombi were directed from the graft veins toward the IVC and captured in the IVC filter with complete elimination of the thrombus without any major complications. We present our technique for the successful treatment of pancreas graft thrombosis within a short time period by percutaneous selective embolectomy using a Fogarty Thru-Lumen Catheter.

  1. The Impact of Anastomotic Angle for Re-Occlusion of Brachioaxillary Graft Arteriovenous Fistula after Percutaneous Thromboaspiration

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Keon Young; Jin, Gong Yong; Hwang, Seung Bae; Choi, Eun Jung; Song, Ji Soo; Han, Young Min; Kwon, Keun Sang [Chonbuk National University Hospital and Medical School, Jeonju (Korea, Republic of)

    2013-03-15

    The purpose of this study is to evaluate the factors that affect graft patency in brachioaxillary graft arteriovenous fistula patients. A retrospective study was conducted on 33 patients (20 men, 13 women; mean age, 67.5 years; mean interval to first stenosis, 17 months), who had performed percutaneous angioplasty for first episode of stenosis after brachioaxillary graft surgery. We evaluated the relevant factors affecting the graft patency after first episode of stenosis, such as age, sex, underlying disease (hypertension, diabetes mellitus, hyperlipidemia, cardiovascular disease, cerebrovascular attack), anastomotic angle between graft and axillary vein, and anastomotic angle between the graft and brachial artery. Kaplan-Meier method and log rank test and receiver operating characteristics curve analysis were used in statistical analysis. Graft patency rates after 1 month, 6 months, and 12 months were 75.8%, 39.4%, and 9.1%. There was a correlation between graft-axillary vein anastomotic angle and patency rates (r = 0.372, p = 0.033); larger the venous anastomotic angle, the longer patency rate. However, it does not come up with significant results in patency rates on age, sex, underlying disease, and graft-brachial artery angle. In patients with brachioaxillary graft arteriovenous fistula, as venous anastomotic angle more obtuse, the graft patency may be longer.

  2. Early Outcomes of Endoscopic Vein Harvesting during the Initial Learning Period

    Directory of Open Access Journals (Sweden)

    Do Yeon Kim

    2015-06-01

    Full Text Available Background: The endoscopic vein harvesting (EVH method has been used in coronary artery bypass surgery in many countries. We started using the EVH method recently, and investigated the results during the early learning period. Methods: Between March 2012 and June 2014, 75 patients (31 patients in the EVH method group, and 44 patients in the open method group who underwent isolated first-time coronary artery bypass grafting using vein grafts were retrospectively analyzed with respect to the early outcomes including graft patency and risk factors for leg wound complications. For assessing the patency of vein graft, we performed coronary computed tomography angiography during the immediate postoperative period and 6 months later. Results: Mean harvesting time of endoscopic method was about 15 minutes. Patency rate during the immediate operative period and the 6-month patency rate were similar between the two groups (postoperative period: EVH 100% vs. open method 94.4%, p=0.493; at 6 months: EVH 93.3% vs. open method 90.9%, p=0.791. Leg wound complications occurred more frequently in the open method group (EVH 3.2% vs. open method 13.6%, p=0.127. According to the analysis, age was an independent risk factor for leg wound complications. Conclusion: EVH is a feasible method even for beginners and can be performed satisfactorily during their learning period.

  3. Late-onset renal vein thrombosis: A case report and review of the literature.

    Science.gov (United States)

    Hogan, Jessica L; Rosenthal, Stanton J; Yarlagadda, Sri G; Jones, Jill A; Schmitt, Timothy M; Kumer, Sean C; Kaplan, Bruce; Deas, Shenequa L; Nawabi, Atta M

    2015-01-01

    Renal vein thrombosis, a rare complication of renal transplantation, often causes graft loss. Diagnosis includes ultrasound with Doppler, and it is often treated with anticoagulation or mechanical thrombectomy. Success is improved with early diagnosis and institution of treatment. We report here the case of a 29 year-old female with sudden development of very late-onset renal vein thrombosis after simultaneous kidney pancreas transplant. This resolved initially with thrombectomy, stenting and anticoagulation, but thrombosis recurred, necessitating operative intervention. Intraoperatively the renal vein was discovered to be compressed by a large ovarian cyst. Compression of the renal vein by a lymphocele or hematoma is a known cause of thrombosis, but this is the first documented case of compression and thrombosis due to an ovarian cyst. Early detection and treatment of renal vein thrombosis is paramount to restoring renal allograft function. Any woman of childbearing age may have thrombosis due to compression by an ovarian cyst, and screening for this possibility may improve long-term graft function in this population. Published by Elsevier Ltd.

  4. Distal vein patch as a form of autologus modification for infragenicular prosthetic bypass.

    Science.gov (United States)

    Totic, Dragan; Rustempasic, Nedzad; Djedovic, Muhamed; Solakovic, Sid; Vukas, Haris; Aslani, Ilijas; Krvavac, Alma; Rudalija, Dzejra; Ahmetasevic, Alen

    2013-01-01

    Preferred graft for infragenicular bypass is autologus vein. The problem is when there is not available autologus vein. Literature suggest that in these situations, prosthetic graft with some form of modification of distal anastomosis with autogenic tissue is valuable adjunctive. Frequently used modifications are Miller's cuff, Taylor's patch and St. Mary's boot. Recently, there are reports on "Distal vein patch" as a form of autologus modification which, due to its simplicity and patency rate, attracted attention. The aim of this study was to evaluate benefits of this novel modification by comparing its patencies with other autologus modification of distal anastomosis. Study was performed on 60 patients, diabetics, with critical limb ischemia (CLI). Patients were divided in two groups: Group with distal vein patch modification; and group with some other form modification - control group. Patients were followed at least 22 months. We examined patency of grafts by physical examination or using Color Doppler. For statistical purposes we used KIaplan Meier analysis and curve. Significance was determined by Mann-Whitney, Fisher's exact, Pearsons chi square or Student T test as appropriate. P value less than 0,05 was considered significant. Groups were fairly matched relative to demographics, risk factors, operative intervention and distal anastomosis site. There was not statistical difference in two year primary patency between distal vein patch and control group--50% vs 53% respectivly (X2 = 0,08; p = 0,773). Also, there was not statistically significant difference in extremity survival (77% vs 77%) and patient survival between groups (89% vs 93%; X2 = 2,458; p = 0,117). This study proved equivalent patencies of infragenicular prosthetic bypasses performed using distal vein patch technique as with any other modification of distal anastomosis.

  5. Emergency Stent Grafting After Unsuccessful Surgical Repair of a Mycotic Common Femoral Artery Pseudoaneurysm in a Drug Abuser

    International Nuclear Information System (INIS)

    Lupattelli, Tommaso; Garaci, Francesco Giuseppe; Basile, Antonio; Minnella, Daniela Paola; Casini, Andrea; Clerissi, Jacques

    2009-01-01

    Mycotic false aneurysm caused by local arterial injury from attempted intravenous injections in drug addicts remains a challenging clinical problem. The continued increase in drug abuse has resulted in an increased incidence of this problem, particularly in high-volume urban centres. In the drug-abusing population, mycotic arterial pseudoaneurysms most often occur because of missed venous injection and are typically seen in the groin, axilla, and antecubital fossa. Mycotic aneurysms may lead to life-threatening haemorrhage, limb loss, sepsis, and even death. Any soft-tissue swelling in the vicinity of a major artery in an intravenous drug abuser should be suspected of being a false aneurysm until proven otherwise and should prompt immediate referral to a vascular surgeon for investigation and management. We report a case of rupturing mycotic pseudoaneurysm of the left common femoral artery treated by surgical resection followed by vessel reconstruction with autologous material. Unfortunately, at the time of discharge a sudden leakage from the vein graft anastomosis occurred, with subsequent massive bleeding, and required emergent endovascular covered stenting. To the best of our knowledge, this is the first reported case of femoral artery bleeding in a drug abuser treated by stent graft placement.

  6. Quadriceps Tendon Autograft Medial Patellofemoral Ligament Reconstruction.

    Science.gov (United States)

    Fink, Christian; Steensen, Robert; Gföller, Peter; Lawton, Robert

    2018-06-01

    Critically evaluate the published literature related to quadriceps tendon (QT) medial patellofemoral ligament (MPFL) reconstruction. Hamstring tendon (HT) MPFL reconstruction techniques have been shown to successfully restore patella stability, but complications including patella fracture are reported. Quadriceps tendon (QT) reconstruction techniques with an intact graft pedicle on the patella side have the advantage that patella bone tunnel drilling and fixation are no longer needed, reducing risk of patella fracture. Several QT MPFL reconstruction techniques, including minimally invasive surgical (MIS) approaches, have been published with promising clinical results and fewer complications than with HT techniques. Parallel laboratory studies have shown macroscopic anatomy and biomechanical properties of QT are more similar to native MPFL than hamstring (HS) HT, suggesting QT may more accurately restore native joint kinematics. Quadriceps tendon MPFL reconstruction, via both open and MIS techniques, have promising clinical results and offer valuable alternatives to HS grafts for primary and revision MPFL reconstruction in both children and adults.

  7. [Localized purpura revealing vascular prosthetic graft infection].

    Science.gov (United States)

    Boureau, A S; Lescalie, F; Cassagnau, E; Clairand, R; Connault, J

    2013-07-01

    Prosthetic graft infection after vascular reconstruction is a rare but serious complication. We report a case of infection occurring late after implantation of an iliofemoral prosthetic vascular graft. The Staphylococcus aureus infection was revealed by vascular purpura localized on the right leg 7 years after implantation of a vascular prosthesis. This case illustrates an uncommonly late clinical manifestation presenting as an acute infection 7 years after the primary operation. In this situation, the presentation differs from early infection, which generally occurs within the first four postoperative months. Diagnosis and treatment remain a difficult challenge because prosthetic graft infection is a potentially life-threatening complication. Morbidity and mortality rates are high. Here we detail specific aspects of the clinical and radiological presentation. Copyright © 2013 Elsevier Masson SAS. All rights reserved.

  8. [Reconstructive methods after Fournier gangrene].

    Science.gov (United States)

    Wallner, C; Behr, B; Ring, A; Mikhail, B D; Lehnhardt, M; Daigeler, A

    2016-04-01

    Fournier's gangrene is a variant of the necrotizing fasciitis restricted to the perineal and genital region. It presents as an acute life-threatening disease and demands rapid surgical debridement, resulting in large soft tissue defects. Various reconstructive methods have to be applied to reconstitute functionality and aesthetics. The objective of this work is to identify different reconstructive methods in the literature and compare them to our current concepts for reconstructing defects caused by Fournier gangrene. Analysis of the current literature and our reconstructive methods on Fournier gangrene. The Fournier gangrene is an emergency requiring rapid, calculated antibiotic treatment and radical surgical debridement. After the acute phase of the disease, appropriate reconstructive methods are indicated. The planning of the reconstruction of the defect depends on many factors, especially functional and aesthetic demands. Scrotal reconstruction requires a higher aesthetic and functional reconstructive degree than perineal cutaneous wounds. In general, thorough wound hygiene, proper pre-operative planning, and careful consideration of the patient's demands are essential for successful reconstruction. In the literature, various methods for reconstruction after Fournier gangrene are described. Reconstruction with a flap is required for a good functional result in complex regions as the scrotum and penis, while cutaneous wounds can be managed through skin grafting. Patient compliance and tissue demand are crucial factors in the decision-making process.

  9. Bacterial adherence to vascular grafts after in vitro bacteremia

    International Nuclear Information System (INIS)

    Rosenman, J.E.; Pearce, W.H.; Kempczinski, R.F.

    1985-01-01

    All currently used arterial prosthetics have a greater susceptibility to infection following bacteremia than does autogenous tissue. This experiment compares quantitative bacterial adherence to various prosthetic materials after bacteremia carried out in a tightly controlled and quantitative fashion. Ten centimeters long, 4 mm i.d. Dacron, umbilical vein (HUV), and polytetrafluoroethylene (PTFE) grafts, as well as PTFE grafts with a running suture line at the midportion were tested. Each graft was interposed into a pulsatile perfusion system modified from a Waters MOX 100 TM renal transplant pump. Indium-111-labeled Staphylococcus aureus were added to heparinized canine blood to give a mean concentration of 4.7 X 10(6) bacteria/cc. This infected blood was recirculated through each graft for 30 min at a rate of 125 cc/m, 100 Torr (sys), 60 beats/min. The gamma counts/graft were used to calculate the number of bacteria/cm2 of graft surface. After nine experiments, a mean of 9.63 X 10(5) bacteria/cm2 were adherent to the Dacron, 1.04 X 10(5) bacteria/cm2 to the HUV, and 2.15 X 10(4) bacteria/cm2 to the PTFE. These differences were all significant at the 0.05 level. The addition of a suture line increased bacterial adherence to the PTFE graft by 50%. These results suggest that PTFE is the vascular graft material of choice when a prosthetic graft must be implanted despite a high risk of subsequent clinical bacteremia. An in vitro, pulsatile perfusion model gave accurate and reproducible results, and appears well suited for further studies of bacterial, or platelet adherence to grafts, as well as the biomechanics of vascular conduits

  10. Influence of Diabetes on Long-Term Coronary Artery Bypass Graft Patency.

    Science.gov (United States)

    Raza, Sajjad; Blackstone, Eugene H; Houghtaling, Penny L; Rajeswaran, Jeevanantham; Riaz, Haris; Bakaeen, Faisal G; Lincoff, A Michael; Sabik, Joseph F

    2017-08-01

    Nearly 50% of patients undergoing coronary artery bypass grafting have diabetes. However, little is known about the influence of diabetes on long-term patency of bypass grafts. Because patients with diabetes have more severe coronary artery stenosis, we hypothesized that graft patency is worse in patients with than without diabetes. This study sought to examine the influence of diabetes on long-term patency of bypass grafts. From 1972 to 2011, 57,961 patients underwent primary isolated coronary artery bypass grafting. Of these, 1,372 pharmacologically treated patients with diabetes and 10,147 patients without diabetes had 15,887 postoperative angiograms; stenosis was quantified for 7,903 internal thoracic artery (ITA) grafts and 20,066 saphenous vein grafts. Status of graft patency across time was analyzed by longitudinal nonlinear mixed-effects modeling. ITA graft patency was stable over time and similar in patients with and without diabetes: at 1, 5, 10, and 20 years, 97%, 97%, 96%, and 96% in patients with diabetes, and 96%, 96%, 95%, and 93% in patients without diabetes, respectively (early p = 0.20; late p = 0.30). In contrast, saphenous vein graft patency declined over time and similarly in patients with and without diabetes: at 1, 5, 10, and 20 years, 78%, 70%, 57%, and 42% in patients with diabetes, and 82%, 72%, 58%, and 41% in patients without diabetes, respectively (early p < 0.002; late p = 0.60). After adjusting for patient characteristic