WorldWideScience

Sample records for vectest antigen assay

  1. Detecting West Nile virus in owls and raptors by an antigen-capture assay.

    Science.gov (United States)

    Gancz, Ady Y; Campbell, Douglas G; Barker, Ian K; Lindsay, Robbin; Hunter, Bruce

    2004-12-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%-95.2% for northern owl species but raptors.

  2. Detecting West Nile Virus in Owls and Raptors by an Antigen-capture Assay

    OpenAIRE

    Gancz, Ady Y.; Campbell, Douglas G.; Barker, Ian K.; Lindsay, Robbin; Hunter, Bruce

    2004-01-01

    We evaluated a rapid antigen-capture assay (VecTest) for detection of West Nile virus in oropharyngeal and cloacal swabs, collected at necropsy from owls (N = 93) and raptors (N = 27). Sensitivity was 93.5%–95.2% for northern owl species but

  3. A rapid one-step radiometric assay for hepatitis B surface antigen utilising monoclonal antibodies

    International Nuclear Information System (INIS)

    Goodall, A.H.; Meek, F.L.; Waters, J.A.; Miescher, G.C.; Janossy, G.; Thomas, H.C.

    1982-01-01

    A two-site antigen assay for HBsAg has been developed that employs 3 monoclonal antibodies. The antibodies were selected for their high affinity and their particular epitope specificity to establish an assay with a sensitivity for the antigen comparable with that of a conventional assay with heterologous antisera. In addition, by selecting a monoclonal antibody for use as a tracer which does not compete for antigenic binding sites with the solid-phase monoclonal antibodies, it has been possible to perform a two-site assay in a single 1 h incubation step, achieving the same degree of sensitivity. This principle of using monoclonal antibodies in a one-step assay therefore gives advantages of speed and simplicity over assays using heterologous antisera and would be applicable to a variety of antigen assays for which appropriate monoclonal antibodies are available. (Auth.)

  4. Fundamental and clinical evaluation of ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen

    International Nuclear Information System (INIS)

    Koizumi, Mitsuru; Endo, Keigo; Nakajima, Kotoko

    1987-01-01

    A commercial ''SCC RIABEAD'' kit for immunoradiometric assay of squamous cell carcinoma related antigen (SCC antigen) was fundamentally and clinically evaluated. Laboratory performance was satisfactory for intra-assay and inter-assay reproducibility, recovery, and dilution, with rapid and simple measurement techniques. Seropositivity for SCC antigen was significantly higher for squamous cell carcinoma of the liver and uterine cervix than the other histology types. In the case of cervical squamous cell carcinoma, it increased with progressing disease. Post-treatment serum levels of SCC antigen returned to negative. SCC antigen is considered to be a useful tumor marker for these diseases. There was a good correlation between the measurement values obtained from the present and conventional (SCC RIAKIT) assays. The present assay remarkably decreased false-positive cases of pulmonary benign diseases. The results showed a ''SCC RIABEAD'' to be a favorable kit for immunoradiometric assay of SSC antigen, as compared with conventional assay kit. (Namekawa, K.)

  5. [Clinical benefit of HCV core antigen assay in patients receiving interferon and ribavirin combination therapy].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Saito, Hidetsugu

    2006-02-01

    A highly sensitive second generation HCV core antigen assay has recently been developed. We compared viral disappearance and kinetics data between commercially available core antigen assays, Lumipulse Ortho HCV Ag, and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor Test, Version 2 to estimate the predictive benefit of sustained viral response (SVR) and non-SVR in 59 patients treated with interferon and ribavirin combination therapy. We found a good correlation between HCV core Ag and HCV RNA level regardless of genotype. Although the sensitivity of the core antigen assay was lower than PCR, the dynamic range was broader than that of the PCR assay, so that we did not need to dilute the samples in 59 patients. We detected serial decline of core Ag levels in 24 hrs, 7 days and 14 days after interferon combination therapy. The decline of core antigen levels was significant in SVR patients compared to non-SVR as well as in genotype 2a, 2b patients compared to 1b. Core antigen-negative on day 1 could predict all 10 SVR patients (PPV = 100%), whereas RNA-negative could predict 22 SVR out of 25 on day 14 (PPV = 88.0%). None of the patients who had detectable serum core antigen on day 14 became SVR(NPV = 100%), although NPV was 91.2% on RNA negativity. An easy, simple, low cost new HCV core antigen detecting system seems to be useful for assessing and monitoring IFN treatment for HCV.

  6. Performance Assessment of a Trypanosoma cruzi Chimeric Antigen in Multiplex Liquid Microarray Assays.

    Science.gov (United States)

    Santos, Fred Luciano Neves; Celedon, Paola Alejandra Fiorani; Zanchin, Nilson Ivo Tonin; Leitolis, Amanda; Crestani, Sandra; Foti, Leonardo; de Souza, Wayner Vieira; Gomes, Yara de Miranda; Krieger, Marco Aurélio

    2017-10-01

    Diagnosing chronic Chagas disease (CD) requires antibody-antigen detection methods, which are traditionally based on enzymatic assay techniques whose performance depend on the type and quality of antigen used. Previously, 4 recombinant chimeric proteins from the Instituto de Biologia Molecular do Paraná (IBMP-8.1 to 8.4) comprising immuno-dominant regions of diverse Trypanosoma cruzi antigens showed excellent diagnostic performance in enzyme-linked immunosorbent assays. Considering that next-generation platforms offer improved CD diagnostic accuracy with different T. cruzi -specific recombinant antigens, we assessed the performance of these chimeras in liquid microarrays (LMAs). The chimeric proteins were expressed in Escherichia coli and purified by chromatography. Sera from 653 chagasic and 680 healthy individuals were used to assess the performance of these chimeras in detecting specific anti- T. cruzi antibodies. Accuracies ranged from 98.1 to 99.3%, and diagnostic odds ratio values were 3,548 for IBMP-8.3, 4,826 for IBMP-8.1, 7,882 for IBMP-8.2, and 25,000 for IBMP-8.4. A separate sera bank (851 samples) was employed to assess cross-reactivity with other tropical diseases. Leishmania , a pathogen with high similarity to T. cruzi , showed cross-reactivity rates ranging from 0 to 2.17%. Inconclusive results were negligible (0 to 0.71%). Bland-Altman and Deming regression analysis based on 200 randomly selected CD-positive and negative samples demonstrated interchangeability with respect to CD diagnostic performance in both singleplex and multiplex assays. Our results suggested that these chimeras can potentially replace antigens currently used in commercially available assay kits. Moreover, the use of multiplex platforms, such as LMA assays employing 2 or more IBMP antigens, would abrogate the need for 2 different testing techniques when diagnosing CD. Copyright © 2017 American Society for Microbiology.

  7. Establishment of immunoradiometric assay for free prostate-specific antigen

    International Nuclear Information System (INIS)

    Ma Lianxue

    2009-01-01

    An immunoradiometric assay (IRMA) of free prostate specific antigen (F-PSA) in serum was established. One monoclonal antibody against total PSA (T-PSA) was coated on the plastic tubes, the other against F-PSA was labeled with 125 I. The sensitivity of assay was 0.04 μg/L (n=20, +2s), the CVs were 2.9%-4.0% for the intra-assay and 3.5%-10.5% for the inter-assay and the average recovery was 102.7%. The correlative equation comparing with the FPSA-RIA (CIS BIO) is y=0.965 1 χ -0.001 1, and r=0.996 4. This F-PSA IRMA is a sensitive and precise method in detecting F-PSA and fit for the vitro assay. (authors)

  8. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    International Nuclear Information System (INIS)

    Ahlstedt, S.; Rylander, H.

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, 125 I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not. (author)

  9. Immunoradiometric assay for quantification of serum antibodies to dental plaque antigen in immunized dogs

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstedt, S; Rylander, H [Goeteborg Univ. (Sweden)

    1975-01-01

    An immunoradiometric assay (IRMA) was used for quantifying dog serum antibodies to antigens from dental plaque collected from full-grown dogs. The antigens were adsorbed onto the inner surface of plastic tubes and then incubated with dog-anti-plaque serum, /sup 125/I-labelled anti-dog plasma-immunoglobulin was used for quantification of the specific antibodies. Four 10 months old Beagle dogs in excellent gingival health were immunized for 10 weeks with ultrasonicated dog dental plaque. The antibody levels in antisera sampled 6, 8, 10 and 11 weeks after the first antigen injection were 2 to 5 times as high as those recorded before the immunizing period. The variability of the assay as judged from the difference between duplicate samples was found to be 18 percent+-4 (p<0.01) of the mean value and the variability between the same serum ran on different test occasions 13 percent+-7 (p<0.01). The specificity of the antigen-antibody reaction in the immuno assay was tested by inhibition experiments. Preincubation of the antisera with dental plaque antigen significantly inhibited the antigen-antibody reaction in the IRMA, while bovine serum albumin did not.

  10. Performance evaluation of new automated hepatitis B viral markers in the clinical laboratory: two quantitative hepatitis B surface antigen assays and an HBV core-related antigen assay.

    Science.gov (United States)

    Park, Yongjung; Hong, Duck Jin; Shin, Saeam; Cho, Yonggeun; Kim, Hyon-Suk

    2012-05-01

    We evaluated quantitative hepatitis B surface antigen (qHBsAg) assays and a hepatitis B virus (HBV) core-related antigen (HBcrAg) assay. A total of 529 serum samples from patients with hepatitis B were tested. HBsAg levels were determined by using the Elecsys (Roche Diagnostics, Indianapolis, IN) and Architect (Abbott Laboratories, Abbott Park, IL) qHBsAg assays. HBcrAg was measured by using Lumipulse HBcrAg assay (Fujirebio, Tokyo, Japan). Serum aminotransferases and HBV DNA were respectively quantified by using the Hitachi 7600 analyzer (Hitachi High-Technologies, Tokyo, Japan) and the Cobas AmpliPrep/Cobas TaqMan test (Roche). Precision of the qHBsAg and HBcrAg assays was assessed, and linearity of the qHBsAg assays was verified. All assays showed good precision performance with coefficients of variation between 4.5% and 5.3% except for some levels. Both qHBsAg assays showed linearity from 0.1 to 12,000.0 IU/mL and correlated well (r = 0.9934). HBsAg levels correlated with HBV DNA (r = 0.3373) and with HBcrAg (r = 0.5164), and HBcrAg also correlated with HBV DNA (r = 0.5198; P < .0001). This observation could provide impetus for further research to elucidate the clinical usefulness of the qHBsAg and HBcrAg assays.

  11. Diagnosis of Fasciola gigantica infection in cattle using capture-ELISA assay for detecting antigen in faeces

    Directory of Open Access Journals (Sweden)

    Sarwitri Endah Estuningsih

    2006-10-01

    Full Text Available Capture-ELISA assay is a diagnosis for antigen detection in the serum or faeces using polyclonal or monoclonal antibodies. The purpose of this study was to determine the sensitivity and specificity of capture-ELISA assay using polyclonal antibody for diagnosing Fasciola gigantica infection in cattle by detecting antigen in the faeces. In this study, faecal samples and livers were collected from 141 cattle slaughtered in the abattoir in Jakarta. From each animal, liver was processed for liver flukes count and the corresponding faecal sample was analysed for coproantigen. The result of capture-ELISA assay for antigen detection showed that from 85 cattle infected with Fasciola gigantica, 83 had OD > 0.52 (range from 0.52-1.39 and 2 cattle had OD < 0.52 (range from 0.17-0.51. The sensitivity and specificity of the assay were 97.6% and 92.8% respectively. The assay also able to detect 50 ng/ml of antigen in faecal supernatant. It suggests that this assay will have the advantage over the other methods on its ability to detect the active infection. Collection of faeces, rather than serum, will allow a more cost-effective and adaptable method.

  12. Detection of target staphylococcal enterotoxin B antigen in orange juice and popular carbonated beverages using antibody-dependent antigen-capture assays.

    Science.gov (United States)

    Principato, MaryAnn; Njoroge, Joyce M; Perlloni, Andrei; O' Donnell, Michael; Boyle, Thomas; Jones, Robert L

    2010-10-01

    There is a critical need for qualitative and quantitative methodologies that provide the rapid and accurate detection of food contaminants in complex food matrices. However, the sensitivity of the assay can be affected when antigen-capture is applied to certain foods or beverages that are extremely acidic. This study was undertaken to assess the effects of orange juice and popular carbonated soft drink upon the fidelity of antibody-based antigen-capture assays and to develop simple approaches that could rescue assay performance without the introduction of additional or extensive extraction procedures. We examined the effects of orange juice and a variety of popular carbonated soft drink beverages upon a quantitative Interleukin-2 (IL-2) enzyme-linked immunosorbent assay (ELISA) assay system and a lateral flow device (LFD) adapted for the detection of staphylococcal enterotoxin B (SEB) in foods. Alterations in the performance and sensitivity of the assay were directly attributable to the food matrix, and alterations in pH were especially critical. The results demonstrate that approaches such as an alteration of pH and the use of milk as a blocking agent, either singly or in combination, will partially rescue ELISA performance. The same approaches permit lateral flow to efficiently detect antigen. Practical Application: The authors present ways to rescue an ELISA assay compromised by acidity in beverages and show that either the alteration of pH, or the use of milk as a blocking agent are not always capable of restoring the assay to its intended efficiency. However, the same methods, when employed with lateral flow technology, are rapid and extremely successful.

  13. Expression of Hepatitis C Virus Core and E2 antigenic recombinant proteins and their use for development of diagnostic assays.

    Science.gov (United States)

    Ali, Amjad; Nisar, Muhammad; Idrees, Muhammad; Rafique, Shazia; Iqbal, Muhammad

    2015-05-01

    Early diagnosis of HCV infection is based on detection of antibodies against HCV proteins using recombinant viral antigens. The present study was designed to select, clone and express the antigenic regions of Core and E2 genes from local HCV-3a genotype and to utilize the antigenic recombinant proteins (Core & E2) to develop highly sensitive, specific and economical diagnostic assays for detection of HCV infection. The antigenic sites were determined within Core and E2 genes and were then cloned in pET-28a expression vector. The right orientation of the desired inserted fragments of Core and E2 were confirmed via sequencing prior to expression and were then transformed in BL21 (DE3) pLysS strains of E. coli and induced with 0.5mM Isopropyl-b-D-thiogalactopyranoside (IPTG) for the production of antigenic recombinant proteins. The produced truncated antigens were then purified by Nickel affinity chromatography and were confirmed by western blotting, immunoblotting and enzyme-linked immunosorbent assay (ELISA). The expressed Core and E2 recombinant antigens were used to develop immunoblotting assay for the detection of anti-HCV antibodies in sera. With immunoblotting, a total of 93-HCV infected sera and 35-HCV negative individuals were tested for the presence of anti-HCV antibodies to the Core and E2 antigens. Recombinant antigen showed 100% reactivity against HCV infected sera, with no cross reactivity against HCV-negative sera. The immunoblot assay mixture of recombinant antigens (Core+E2) showed a strong reaction intensity in the test area (TA) as compared to the individual truncated Core and E2 recombinant antigens. In the in-house ELISA assay, mixed Core and E2 recombinant antigens showed 100% reactivity against a standardized panel of 150-HCV-positive sera and non reactivity against a standardized panel of 150 HCV-negative sera while also being non reactive to sera positive for other viral infections. The antigenic recombinant antigens also were tested for the

  14. Evaluation of five hepatitis delta virus marker assays for detection of antigen and antibody.

    OpenAIRE

    Bezeaud, A; Rosenswajg, M; Guillin, M C

    1989-01-01

    Five commercially available assays for hepatitis delta (HD) virus markers were compared for sensitivity, specificity, and reproducibility: three assays for antibody (anti-HD), provided by Diagnostics Pasteur, Organon Teknika, and Abbott Laboratories, and two assays for antigen (HD Ag), from Pasteur and Organon Teknika. The assay from Organon Teknika is the less sensitive assay for anti-HD detection. Although the sensitivities of the Pasteur and Abbott assays for anti-HD detection are similar,...

  15. Limitations of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) for detection of filarial antigens in serum

    International Nuclear Information System (INIS)

    Hamilton, R.G.; Alexander, E.; Adkinson, N.F.

    1984-01-01

    The performance of the radioimmunoprecipitation polyethylene glycol assay (RIPEGA) was examined for quantitation of filarial antigens (Brugia malayi and Dirofilaria immitis) in serum from infected human and animal hosts and non-infected controls. Multiple PEG concentrations were employed to determine the level of non-specific binding (NSB) in non-exposed human sera (NEHS) containing no filarial antigen. The NSB observed when 3 different 125 I-labelled IgG antibodies were added to 26 NEHS varied 3-fold and was correlated significantly with total serum IgM (r = 0.80, P 2 fragment of the 125 I-labelled antibody was used, but the correlation of NSB with total serum IgM remained significant (r = 0.57, P < 0.01). The presence of rheumatoid factor in NEHS sera also significantly increased NSB by an average of 3-fold. These effects eliminated the assay's ability to detect in sera from infected hosts filarial antigen the presence of which could be readily demonstrated by an immunoradiometric assay. The RIPEGA's precision (intra-assay coefficient of variation (CV) = 21% at 35% Bsub(max)) and reproducibility (inter-assay CV = 29% at 35% Bsub(max)) are less satisfactory than many alternative immunoassays. (Auth.)

  16. Automation of the ELISpot assay for high-throughput detection of antigen-specific T-cell responses.

    Science.gov (United States)

    Almeida, Coral-Ann M; Roberts, Steven G; Laird, Rebecca; McKinnon, Elizabeth; Ahmed, Imran; Pfafferott, Katja; Turley, Joanne; Keane, Niamh M; Lucas, Andrew; Rushton, Ben; Chopra, Abha; Mallal, Simon; John, Mina

    2009-05-15

    The enzyme linked immunospot (ELISpot) assay is a fundamental tool in cellular immunology, providing both quantitative and qualitative information on cellular cytokine responses to defined antigens. It enables the comprehensive screening of patient derived peripheral blood mononuclear cells to reveal the antigenic restriction of T-cell responses and is an emerging technique in clinical laboratory investigation of certain infectious diseases. As with all cellular-based assays, the final results of the assay are dependent on a number of technical variables that may impact precision if not highly standardised between operators. When studies that are large scale or using multiple antigens are set up manually, these assays may be labour intensive, have many manual handling steps, are subject to data and sample integrity failure and may show large inter-operator variability. Here we describe the successful automated performance of the interferon (IFN)-gamma ELISpot assay from cell counting through to electronic capture of cytokine quantitation and present the results of a comparison between automated and manual performance of the ELISpot assay. The mean number of spot forming units enumerated by both methods for limiting dilutions of CMV, EBV and influenza (CEF)-derived peptides in six healthy individuals were highly correlated (r>0.83, pautomated system compared favourably with the manual ELISpot and further ensured electronic tracking, increased through-put and reduced turnaround time.

  17. Evaluation of performance of human immunodeficiency virus antigen/antibody combination assays in Taiwan.

    Science.gov (United States)

    Chang, Chun-Kai; Kao, Cheng-Feng; Lin, Pi-Han; Huang, Hui-Lin; Ho, Shu-Yuan; Wong, Kuo-Chen; Lin, Bo-Chang; Yeh, Chang-Ching; Lee, Chia-Yeh; Kao, Chuan-Liang; Lee, Chun-Nan; Chang, Sui-Yuan; Yang, Jyh-Yuan

    2017-08-01

    The fourth-generation human immunodeficiency virus (HIV) combination assay, which can simultaneously detect the presence of anti-HIV antibody and HIV antigen, has been shown to shorten the window period in HIV diagnosis compared with the third-generation HIV antibody immunoassay. This study was aimed to determine the performance of HIV combination assays in Taiwan, where the HIV-1 seroprevalence is 0.007% and HIV-2 infection has never been reported. Performance of three fourth-generation HIV Ag/Ab combination assays (Dia.Pro, Wantai, and Bio-Rad) and one third-generation HIV Ab immunoassay (AxSYM HIV 1/2 gO) was assessed. A total of 152 specimens, including 86 confirmed HIV-seropositive and 66 HIV-seronegative samples, were used in the study. The sensitivity of four assays varied from 98.8% to 100%, and specificity varied from 98.5% to 100%. Performance of the 75 equivocal samples, the HIV status of which was confirmed later, in terms of negative prediction varied from 81.8% to 87.5%. The Bio-Rad and Dia.Pro assays exhibited higher sensitivity for the detection of p24 antigen among the three fourth-generation HIV combination assays. The three fourth-generation HIV Ag/Ab combination assays exhibited better sensitivity, specificity, and negative prediction than the third-generation HIV Ab immunoassay. Copyright © 2015. Published by Elsevier B.V.

  18. Evaluation of the specificity of antigen assays for plasminogen activator inhibitor 1 : Comparison of two new commercial kits

    NARCIS (Netherlands)

    Huisman, L.G.M.; Meijer, P.; Griensven, J. van; Kluft, C.

    1992-01-01

    t-PA depleted citrated plasma was used to prepare standards of different molecular forms of plasminogen activator inhibitor 1 (PAI-1). These standards were used to evaluate the specificity of two new PAI-1 antigen assays: the TintElize PAI-1 antigen assay (cat. no. 210221) and the Innotest PAI-1.

  19. Two types of nanoparticle-based bio-barcode amplification assays to detect HIV-1 p24 antigen

    Directory of Open Access Journals (Sweden)

    Dong Huahuang

    2012-08-01

    Full Text Available Abstract Background HIV-1 p24 antigen is a major viral component of human immunodeficiency virus type 1 (HIV-1 which can be used to identify persons in the early stage of infection and transmission of HIV-1 from infected mothers to infants. The detection of p24 is usually accomplished by using an enzyme-linked immunosorbent assay (ELISA with low detection sensitivity. Here we report the use of two bio-barcode amplification (BCA assays combined with polymerase chain reaction (PCR and gel electrophoresis to quantify HIV-1 p24 antigen. Method A pair of anti-p24 monoclonal antibodies (mAbs were used in BCA assays to capture HIV-1 p24 antigen in a sandwich format and allowed for the quantitative measurement of captured p24 using PCR and gel electrophoresis. The first 1 G12 mAb was coated on microplate wells or magnetic microparticles (MMPs to capture free p24 antigens. Captured p24 in turn captured 1D4 mAb coated gold nanoparticle probes (GNPs containing double-stranded DNA oligonucleotides. One strand of the oligonucleotides was covalently immobilized whereas the unbound complimentary bio-barcode DNA strand could be released upon heating. The released bio-barcode DNA was amplified by PCR, electrophoresed in agarose gel and quantified. Results The in-house ELISA assay was found to quantify p24 antigen with a limit of detection (LOD of 1,000 pg/ml and a linear range between 3,000 and 100,000 pg/ml. In contrast, the BCA-based microplate method yielded an LOD of 1 pg/ml and a linear detection range from 1 to 10,000 pg/ml. The BCA-based MMP method yielded an LOD of 0.1 pg/ml and a linear detection range from 0.1 to 1,000 pg/ml. Conclusions When combined with PCR and simple gel electrophoresis, BCA-based microplate and MMPs assays can be used to quantify HIV-1 p24 antigen. These methods are 3–4 orders of magnitude more sensitive than our in-house ELISA-based assay and may provide a useful approach to detect p24 in patients newly infected

  20. Use of Novel Recombinant Antigens in the Interferon Gamma Assay for Detection of Mycobacterium Avium Subsp. Paratuberculosis Infection in Cattle

    DEFF Research Database (Denmark)

    Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose

    2012-01-01

    of the study were to evaluate immunogenicity and specificity of 14 novel recombinant antigens for use in the IFN-γ assay and to assess the consistency of IFN-γ responses. The antigens used were 4 ESAT-6 family members, 4 latency proteins, 4 secreted proteins including Ag85B, 3 other antigens and PPDj......Early stage Mycobacterium avium subsp. paratuberculosis (MAP) infection can be detected by measuring antigen specific cell mediated immune responses by the interferon gamma (IFN-γ) assay. Available IFN-γ assay use purified protein derivate of Johnin (PPDj) leading to low specificity. The objectives...... of the infected and non-infected herds were significantly (Passay using PPDj did not correlate with the results using the novel antigens since 5 of the 17 animals that were positive to PPDj were...

  1. Development of a new in vivo kit for detection of prostate specific antigen in human serum using immunoradiometric assay method

    International Nuclear Information System (INIS)

    Babaei, M. H.; Behradkia, P.; Shafii, M.; Movla, M.; Forutan, H.; Najafi, R.

    2006-01-01

    Prostate is a leading site for the cancer incidence, accounted for 31.0% of new cancer cases in men. Prostate-specific antigen is widely used in the detection and monitoring of the prostate cancer. Currently, immunoassay is used to detect Prostate-specific antigen in human serum. This technique is based on the interaction between antibody and antigen. The varied immunoassay formats and equipment to run the assays allow the users to measure the analytes rapidly, with the flexibility to run a small or a large number of samples. Among different immunoassay methods, immunoradiometric assay is a more sensitive and valuable detection approach. This study has been made in 4 parts: (1) purification of Prostate-specific antigen from seminal fluid; (2) preparation of hybridoma cells which secrete monoclonal antibody (mAb) against Prostate-specific antigen , (3) selection of pair monoclonal antibody among those antibodies, and finally (4) design of an immunoradiometric assay kit and it's quality control . The results of this study were: (1) obtaining a huge amount of Prostate-specific antigen as semi-purified and purified, that is a valuable material for preparation of standard kits; (2) preparation of 8 kinds of monoclonal antibodies; (3) finding 4 pairs of monoclonal antibodies which react with different epitopes on Prostate-specific antigen molecule; and (4) preparation of immunoradiometric assay kit for measuring Prostate-specific antigen concentration in human serum

  2. Preparation of anti-CEA and anti-goat γ-globulin sera for radioimmunologic assay of carcinoembryonic antigen

    International Nuclear Information System (INIS)

    Kusnierczyk-Glazman, H.; Breborowicz, J.

    1977-01-01

    Goats were immunized with purified carcinoembryonic antigen, and the suitability of the antisera for clinical assays of carcinoembryonic antigen was characterized. Reactivity of equine sera to goat γ-globulin as a precipitating factor in the radioimmunologic double antibody technique was also evaluated. (author)

  3. Benefit of Hepatitis C Virus Core Antigen Assay in Prediction of Therapeutic Response to Interferon and Ribavirin Combination Therapy

    OpenAIRE

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) ...

  4. Chagas disease-specific antigens: characterization of epitopes in CRA/FRA by synthetic peptide mapping and evaluation by ELISA-peptide assay.

    Science.gov (United States)

    Bottino, Carolina G; Gomes, Luciano P; Pereira, José B; Coura, José R; Provance, David William; De-Simone, Salvatore G

    2013-12-03

    The identification of epitopes in proteins recognized by medically relevant antibodies is useful for the development of peptide-based diagnostics and vaccines. In this study, epitopes in the cytoplasmic repetitive antigen (CRA) and flagellar repetitive antigen (FRA) proteins from Trypanosoma cruzi were identified using synthetic peptide techniques and pooled sera from Chagasic patients. The epitopes were further assayed with an ELISA assay based on synthetic peptides. Twenty-two overlapping synthetic peptides representing the coding sequence of the T. cruzi CRA and FRA proteins were assessed by a Spot-synthesis array analysis using sera donated by patients with Chagas disease. Shorter peptides were selected that represented the determined epitopes and synthesized by solid phase synthesis to evaluate the patterns of cross-reactivities and discrimination through an ELISA-diagnostic assay. The peptide Spot-synthesis array successfully identified two IgG antigenic determinants in the CRA protein and four in FRA. Bioinformatics suggested that the CRA antigens were unique to T. cruzi while the FRA antigen showed similarity with sequences present within various proteins from Leishmania sp. Subsequently, shorter peptides representing the CRA-1, CRA-2 and FRA-1 epitopes were synthesized by solid phase synthesis and assayed by an ELISA-diagnostic assay. The CRA antigens gave a high discrimination between Chagasic, Leishmaniasis and T. cruzi-uninfected serum. A sensitivity and specificity of 100% was calculated for CRA. While the FRA antigen showed a slightly lower sensitivity (91.6%), its specificity was only 60%. The epitopes recognized by human anti-T. cruzi antibodies have been precisely located in two biomarkers of T. cruzi, CRA and FRA. The results from screening a panel of patient sera through an ELISA assay based on peptides representing these epitopes strongly suggest that the sequences from CRA would be useful for the development of diagnostic reagents that could

  5. How-to-do-it: Immunological Assays for the Classroom 1. Enzyme Linked Immunosorbent Assay (ELISA): A Laboratory Tool for Demonstration of Antibody-Antigen Interaction.

    Science.gov (United States)

    Russo, A. J.; And Others

    1984-01-01

    Background information, list of required materials, and procedures are provided for an immunological assay which has been modified for use as a classroom/laboratory demonstration of antigen-antibody reaction. The assay is designed for a two and one-half hour laboratory period but may be modified for one hour laboratories. (JN)

  6. Indirect solid-phase immunosorbent assay for detection of arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A [Institute of Poliomyelitis anU Viral Encephalities of the U.S.S.R. Academy of Medical Sciences, Moscow

    1984-05-01

    Indirect enzyme-linked immunosorbent assay (ELISA) and solid phase radioimmunoassay (SPRIA) using either enti-human or anti-mouse IgG labelled with horseradish peroxidase and /sup 125/I, respectively, were developed for the detection of Junin, Machupo, Tacaribe, Amapari, Tamiami, Lassa and LCM arenaviruses. Both methods allow high sensitivity detection of arenavirus antigens and antibodies.

  7. A sensitive immunoradiometric assay for the detection of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Cameron, C.H.; Combridge, B.S.; Howell, D.R.; Barbara, J.A.J.

    1980-01-01

    A solid-phase immunoradiometric assay for hepatitis B surface antigen is described which has been in use since 1972. Initially it was used for reference laboratory work, but from 1974 it has also been used for screening blood and blood products. Methods for the production of reagents and their use in blood transfusion and reference work, are outlined. (Auth.)

  8. Sensitivity of hepatitis C virus core antigen and antibody combination assays in a global panel of window period samples

    Science.gov (United States)

    Laperche, Syria; Nubling, C. Micha; Stramer, Susan L.; Brojer, Ewa; Grabarczyk, Piotr; Yoshizawa, Hiroshi; Kalibatas, Vytenis; El Elkyabi, Magdy; Moftah, Faten; Girault, Annie; van Drimmelen, Harry; Busch, Michael P.; Lelie, Nico

    2016-01-01

    BACKGROUND Hepatitis C virus (HCV) antigen and antibody combination assays have been launched as a cost-effective alternative to nucleic acid testing (NAT) for reducing the antibody-negative window period (WP). Later, a HCV antigen chemiluminescence immunoassay (CLIA) became available. STUDY DESIGN AND METHODS A panel composed of 337 HCV NAT–yield samples that were characterized for viral load (VL) and genotype was used to compare the sensitivity of two combination enzyme-linked immunosorbent assays (Monolisa, Bio-Rad; and Murex, formerly Abbott) and a HCV antigen CLIA (Abbott). Analytic sensitivity was compared with HCV RNA detection using Ultrio (Grifols) by testing serial dilutions of 10 genotype (gt)1 to gt4 samples. RESULTS HCV antigen CLIA detected 92.4% of samples, whereas Monolisa and Murex detected 38.3 and 47.5%, respectively. In the HCV RNA VL range of 105 to 107 IU/mL, Monolisa and Murex detected 38% to 56% of gt1, 85% to 78% of gt2, and 21% to 37% of gt3. The overall geometric mean 50% limit of detection (range) of Ultrio on gt1 to gt4 dilution series was 3.5 (1.2–7.7) copies/mL, compared to 3.3 × 106 (4.4 × 105-2.7 × 107), 3.4 × 106 (2.2 × 105–4.2 × 107), and 2728 (415–7243) copies/mL for Monolisa, Murex, and HCV antigen CLIA, respectively. CONCLUSION Analytical sensitivity of NAT was on average 1 million- and 780-fold higher than combination assays and HCV antigen CLIA, respectively. Relative sensitivities of combination assays differed for genotypes with Murex being more sensitive for gt1 and gt3 and Monolisa more sensitive for gt2. Although being less sensitive than NAT, combination assays could be considered in resource-limited settings since they detect 38% to 47% of seronegative WP donations. PMID:26013970

  9. A novel dendritic cell-based direct ex vivo assay for detection and enumeration of circulating antigen-specific human T cells.

    Science.gov (United States)

    Carrio, Roberto; Zhang, Ge; Drake, Donald R; Schanen, Brian C

    2018-05-07

    Although a variety of assays have been used to examine T cell responses in vitro, standardized ex vivo detection of antigen-specific CD4 + T cells from human circulatory PBMCs remains constrained by low-dimensional characterization outputs and the need for polyclonal, mitogen-induced expansion methods to generate detectable response signals. To overcome these limitations, we developed a novel methodology utilizing antigen-pulsed autologous human dendritic target cells in a rapid and sensitive assay to accurately enumerate antigen-specific CD4 + T cell precursor frequency by multiparametric flow cytometry. With this approach, we demonstrate the ability to reproducibly quantitate poly-functional T cell responses following both primary and recall antigenic stimulation. Furthermore, this approach enables more comprehensive phenotypic profiling of circulating antigen-specific CD4 + T cells, providing valuable insights into the pre-existing polarization of antigen-specific T cells in humans. Combined, this approach permits sensitive and detailed ex vivo detection of antigen-specific CD4 + T cells delivering an important tool for advancing vaccine, immune-oncology and other therapeutic studies.

  10. The diagnostic value of the fibrinogen/fibrin fragment E antigen assay in clinically suspected deep vein thrombosis

    International Nuclear Information System (INIS)

    Zielinsky, A.; Hirsh, J.; Straumanis, G.; Carter, C.J.; Gent, M.; Sackett, D.L.; Hull, R.; Kelton, J.G.; Powers, P.; Turpie, A.G.

    1982-01-01

    We have evaluated the fibrinogen/fibrin fragment E antigen assay as a diagnostic test in patients with clinically suspected venous thrombosis by comparing the results of this assay with venography in 272 patients. The result of the fragment E antigen assay was elevated in 79 of 80 patients with positive venograms for recent venous thrombosis (sensitivity 99%) and within the normal range in 161 of 192 patients with normal venograms (specificity 84%). The fragment E assay was also evaluated in 130 medical and surgical controls without evidence of venous thrombosis by leg scanning and the test was found to be relatively nonspecific. However, in the patient group under study, a correct clinical diagnosis of no thrombosis, based on a normal fragment E result, was made in 161 of 162 cases (negative predictive value of 99%). Therefore, a normal test result effectively excludes a diagnosis of venous thrombosis in clinically symptomatic patients. The assay, as currently performed, is technically demanding and takes 24 hr to complete. Therefore, it will have to be simplified before it can be applied to clinical practice

  11. The diagnostic value of the fibrinogen/fibrin fragment E antigen assay in clinically suspected deep vein thrombosis

    International Nuclear Information System (INIS)

    Zielinsky, A.; Hirsh, J.; Straumanis, G.; Carter, C.J.; Gent, M.; Sackett, D.L.; Hull, R.; Kelton, J.G.; Powers, P.

    1982-01-01

    We have evaluated the fibrinogen/fibrin fragment E antigen assay as a diagnostic test in patients with clinically suspected venous thrombosis by comparing the results of this assay with venography in 272 patients. The result of the fragment E antigen assay was elevated in 79 of 80 patients with positive venograms for recent venous thrombosis (sensitivity 99%) and within the normal range in 161 of 192 patients with normal venograms (specificity 84%). The fragment E assay was also evaluated in 130 medical and surgical controls without evidence of venous thrombosis by leg scanning and the test was found to be relatively nonspecific. However, in the patient group under study, a correct clinical diagnosis of no thrombosis, based on a normal fragment E result, was made in 161 of 162 cases (negative predictive value 99%). Therefore, a normal test result effectively excludes a diagnosis of venous thrombosis in clinically symptomatic patients. The assay, as currently performed, is technically demanding and takes 24 hr to complete. Therefore, it will have to be simplified before it can be applied to clinical practice

  12. An improved haemolytic plaque assay for the detection of cells secreting antibody to bacterial antigens

    DEFF Research Database (Denmark)

    Barington, T; Heilmann, C

    1992-01-01

    Recent advances in the development of conjugate polysaccharide vaccines for human use have stimulated interest in the use of assays detecting antibody-secreting cells (AbSC) with specificity for bacterial antigens. Here we present improved haemolytic plaque-forming cell (PFC) assays detecting Ab......SC with specificity for tetanus and diphtheria toxoid as well as for Haemophilus influenzae type b and pneumococcal capsular polysaccharides. These assays were found to be less time consuming, more economical and yielded 1.9-3.4-fold higher plaque numbers than traditional Jerne-type PFC assays. In the case of anti......-polysaccharide antibodies aggregation of secreted monomeric antibody (IgG) is critical for plaque formation and increases the avidity of binding to target cells....

  13. Enzyme-linked immunosorbent assays for detection of equine antibodies specific to Sarcocystis neurona surface antigens.

    Science.gov (United States)

    Hoane, Jessica S; Morrow, Jennifer K; Saville, William J; Dubey, J P; Granstrom, David E; Howe, Daniel K

    2005-09-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM.

  14. A simple assay for the detection of antibodies to endocrine islet cell surface antigens

    International Nuclear Information System (INIS)

    Contreas, G.; Madsen, O.D.; Vissing, H.; Lernmark, Aa.

    1986-01-01

    A simple and sensitive immunoradiometric assay for the detection of islet cell surface antibodies (CIRMA) has been developed. Live, transformed islet cells derived from a liver metastasis of a transplantable islet cell tumor were grown in removable microtiter wells and incubated with antibody. Cell-bound antibodies were quantitated using 125 I-labelled second antibodies. The assay was used to detect islet cell antibodies present in sera from non-diabetic and diabetic BB rats and proved to be particularly effective for screening hybridoma supernatants in order to identify monoclonal antibodies recognizing islet cell surface antigens. (Auth.)

  15. Detection of antibodies to the extractable nuclear antigens by enzyme linked immunosorbent assay

    International Nuclear Information System (INIS)

    Aziz, Khalil A.; Fzizal, Abul A.

    2005-01-01

    Anti-extractable nuclear antigen (ENA) antibodies are a group of autoantibodies that are directed against various components of the cell nucleus. Antibodies to these antigens are closely associated with connective tissue disease. Early diagnosis of these diseases can prove very difficult and therefore clinicians rely on the use of anti-ENA antibody testing for the exclusion. Old methods of testing are time consuming and require great skills. For these reasons clinical immunology laboratories are switching to testing for anti-ENA antibodies by enzyme linked immunosorbent assay (ELISA). The latter assays are more sensitive and require little skills. In the present study we have investigated a number of different ELISA preparations. The study was conducted at Birmingham Heartlands Hospital during the period 2003. We tested a number of ENA-positive and negative samples using 3 different commercial ELISA preparations and compared the results with traditional CCIE-assay. The present study revealed that some ELISA preparations can be more sensitive than CCIE method. Laboratories still using later method should switch to ELISA. However it is important that laboratories evaluate a long range of different ELISA preparations before selecting the most optimal one. In addition it is recommended that laboratories then audit results in order to determine true significance of such results. Finally until the true significance of ELISA generated results is known, positive ENA-results should be interpreted in conjunction with the clinical picture and this would require close liaison in between the clinical immunology laboratory and clinicians

  16. Fibrin related antigens: assay development, clinical and kinetic studies

    Energy Technology Data Exchange (ETDEWEB)

    Kruskal, J B

    1987-08-01

    This thesis describes an assay which is able to measure and to determine the proportions of fibrin- and fibrinogen-related antigens (FRA) present in clinical samples. No assay exists at present which is capable of distinguishing between fibrin and fibrinogen degradation products concurrently and in a clinical setting. The assay may be used as a tool with which to gain further insight to pathophysiology of disorders characterized by activation of the coagulation and fibrinolytic pathways. This study provides and analysis of the FRA profiles in patients with disorders characterised by possible enhanced fibrinolytic activity. Studies have been undertaken on patients with acute and chronic liver diseases, on patients with the various syndromes of coronary artery disease and on patients with insulin-dependent diabetes mellitus with and without evidence of microvascular disease. Certain observations made it evident that further studies were required in order to explain previously undocumented fibrinolytic abnormalities in certain patient groups. Data obtained from patients with liver disease provided information compatible with the activation of their fibrinolytic pathways. The initial scope of this study was then extended to further investigate the deranged haemostatic mechanisms in patients with severe liver diseases. Kinetic studies were performed which required the development of specific technology to be able to measure certain previously undertermined parameters. Mathematical models describing the rates of fibrin formation and lysis were developed for human studies. Fibrin-derived D-dimer was radiolabelled and its validity as and intravenous tracer and maker of fibrin degradation established.

  17. Comparison of a newly developed automated and quantitative hepatitis C virus (HCV) core antigen test with the HCV RNA assay for clinical usefulness in confirming anti-HCV results.

    Science.gov (United States)

    Kesli, Recep; Polat, Hakki; Terzi, Yuksel; Kurtoglu, Muhammet Guzel; Uyar, Yavuz

    2011-12-01

    Hepatitis C virus (HCV) is a global health care problem. Diagnosis of HCV infection is mainly based on the detection of anti-HCV antibodies as a screening test with serum samples. Recombinant immunoblot assays are used as supplemental tests and for the final detection and quantification of HCV RNA in confirmatory tests. In this study, we aimed to compare the HCV core antigen test with the HCV RNA assay for confirming anti-HCV results to determine whether the HCV core antigen test may be used as an alternative confirmatory test to the HCV RNA test and to assess the diagnostic values of the total HCV core antigen test by determining the diagnostic specificity and sensitivity rates compared with the HCV RNA test. Sera from a total of 212 treatment-naive patients were analyzed for anti-HCV and HCV core antigen both with the Abbott Architect test and with the molecular HCV RNA assay consisting of a reverse transcription-PCR method as a confirmatory test. The diagnostic sensitivity, specificity, and positive and negative predictive values of the HCV core antigen assay compared to the HCV RNA test were 96.3%, 100%, 100%, and 89.7%, respectively. The levels of HCV core antigen showed a good correlation with those from the HCV RNA quantification (r = 0.907). In conclusion, the Architect HCV antigen assay is highly specific, sensitive, reliable, easy to perform, reproducible, cost-effective, and applicable as a screening, supplemental, and preconfirmatory test for anti-HCV assays used in laboratory procedures for the diagnosis of hepatitis C virus infection.

  18. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens

    Directory of Open Access Journals (Sweden)

    Ondigo Bartholomew N

    2012-12-01

    Full Text Available Abstract Background Multiplex cytometric bead assay (CBA have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Methods Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Results Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from Conclusion With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in positive samples and lower background readings for blank samples than ELISA.

  19. Immunodiagnosis of fascioliasis using sandwich enzyme-linked immunosorbent assay for detection of Fasciola gigantica paramyosin antigen

    Science.gov (United States)

    Abou-Elhakam, Hany Mohamed Adel; Bauomy, Ibraheem Rabia; El Deeb, Somaya Osman; El Amir, Azza Mohamed

    2013-01-01

    Background: Many immunological techniques have been developed over years using the different Fasciola antigens for diagnosis of parasitic infection and to replace the parasitological techniques, which are time consuming and usually lack sensitivity and reproducibility. Materials and Methods: In this study, Fasciola gigantica paramyosin (Pmy) antigen was early detected in cattle sera using sandwich enzyme-linked immunosorbent assay (ELISA), to evaluate the Pmy antigen performance in diagnosis. This work was conducted on 135 cattle blood samples, which were classified according to parasitological investigation into, healthy control (30), fascioliasis (75), and other parasites (30) groups. Results: The sensitivity of Sandwich ELISA was 97.33%, and the specificity was 95%, in comparison with parasitological examination, which recorded 66.66% sensitivity and 100% specificity, respectively. Conclusions: It was clear that the native F. gigantica Pmy is considered as a powerful antigen in early immunodiagnosis of fascioliasis, using a highly sensitive and specific sandwich ELISA technique. PMID:23961441

  20. Detection of hepatitis B surface antigen by solid phase radioimmunoassay and immunometric assay (using enhanced luminescence)

    International Nuclear Information System (INIS)

    Nicholson, S.; Efandis, T.; Gust, I.

    1991-01-01

    A study was performed to assess the sensitivity and specificity of the amerlite monoclonal immunoassay for detection of hepatitis B surface antigen (HBsAG) by comparison with the Abbott Ausria II radioimmunoassay (RI). Serial bleeds from 34 patients with acute or chronic hepatitis B were tested by both assays. The Abbott Ausria II assay detected HBsAG longer than the Amersham Amerlite assay on two occasions and earlier on one occasion. Twelve patients with low HBsAg positive results (confirmed by Ausria II) were tested by the Amerlite assay, four were repeatably positive, five repeatably negative and three gave borderline results (which on repeat testing were negative). A similar trend was seen when a panel of sera containing known concentrations of HBsAG was tested. Replicate testing of 10 specimens eight times showed very good reproducibility by the Amerlite assay. Overall, the specificity of both assays was comparable, however differences in sensitivity were observed. 3 tabs

  1. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    OpenAIRE

    Alderete, J F

    1984-01-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses durin...

  2. An analytical approach to reduce between-plate variation in multiplex assays that measure antibodies to Plasmodium falciparum antigens.

    Science.gov (United States)

    Fang, Rui; Wey, Andrew; Bobbili, Naveen K; Leke, Rose F G; Taylor, Diane Wallace; Chen, John J

    2017-07-17

    Antibodies play an important role in immunity to malaria. Recent studies show that antibodies to multiple antigens, as well as, the overall breadth of the response are associated with protection from malaria. Yet, the variability and reliability of antibody measurements against a combination of malarial antigens using multiplex assays have not been well characterized. A normalization procedure for reducing between-plate variation using replicates of pooled positive and negative controls was investigated. Sixty test samples (30 from malaria-positive and 30 malaria-negative individuals), together with five pooled positive-controls and two pooled negative-controls, were screened for antibody levels to 9 malarial antigens, including merozoite antigens (AMA1, EBA175, MSP1, MSP2, MSP3, MSP11, Pf41), sporozoite CSP, and pregnancy-associated VAR2CSA. The antibody levels were measured in triplicate on each of 3 plates, and the experiments were replicated on two different days by the same technician. The performance of the proposed normalization procedure was evaluated with the pooled controls for the test samples on both the linear and natural-log scales. Compared with data on the linear scale, the natural-log transformed data were less skewed and reduced the mean-variance relationship. The proposed normalization procedure using pooled controls on the natural-log scale significantly reduced between-plate variation. For malaria-related research that measure antibodies to multiple antigens with multiplex assays, the natural-log transformation is recommended for data analysis and use of the normalization procedure with multiple pooled controls can improve the precision of antibody measurements.

  3. Anti-human neutrophil antigen-1a, -1b, and -2 antibodies in neonates and children with immune neutropenias analyzed by extracted granulocyte antigen immunofluorescence assay.

    Science.gov (United States)

    Onodera, Rie; Kurita, Emi; Taniguchi, Kikuyo; Karakawa, Shuhei; Okada, Satoshi; Kihara, Hirotaka; Fujii, Teruhisa; Kobayashi, Masao

    2017-11-01

    Anti-human neutrophil antigen (HNA) antibodies have been implicated in the development of neonatal alloimmune neutropenia (NAN) and autoimmune neutropenia (AIN). There are many conventional assay methods that detect anti-HNA antibodies. However, a method to measure multiple samples and detect several anti-HNA antibodies simultaneously is needed. We developed a new method, the extracted granulocyte antigen immunofluorescence assay (EGIFA), to analyze anti-HNA-1a, -1b, and -2 antibodies in sera. The results obtained by EGIFA were evaluated in comparison with those from several standard assay methods. Anti-HNA antibodies in serum samples from nine familial cases with suspected NAN (n = 19) and children with suspected AIN (n = 88) were also measured by EGIFA. The evaluation of nine serum samples with anti-HNA antibodies suggested that EGIFA demonstrated equivalent specificity and superior sensitivity to monoclonal antibody-specific immobilization of granulocyte antigens and had comparable sensitivity to the granulocyte indirect immunofluorescence test. EGIFA successfully detected anti-HNA-1a or -1b antibodies in seven of nine familial cases with suspected NAN. EGIFA detected anti-HNA antibodies in 40.9% of children with suspected AIN. Among them, isolated anti-HNA-1a or -1b antibody was detected in 4.5 or 12.5% of children, respectively, and anti-HNA-2 antibody was identified in 3.4% of children. The 30.8% (16 of 52) of children negative for anti-HNA antibody by EGIFA were positive for anti-HLA antibody. EGIFA facilitated the measurement of anti-HNA-1a, -1b, and/or -2 antibodies in sera. The prompt measurement of anti-HNA antibodies will improve the diagnosis and clinical management of patients with suspected NAN or AIN. © 2017 AABB.

  4. Immune chromatography: a quantitative radioimmunological assay

    International Nuclear Information System (INIS)

    Davis, J.W.; Demetriades, M.; Bowen, J.M.

    1984-01-01

    Immune chromatography, a radioimmunological binding assay, employs paper chromatography to separate immune complexes from free antigen and antibodies. During chromatography free antigen and antibodies become distributed throughout the paper, while immune complexes remain near the bottoms of the strips. The chromatographic differences can be made quantitative by using either iodinated antigens or antibodies. Under these conditions nanogram quantities of antigen can be detected or antibodies in sera diluted several 1000-fold. The immune chromatography assay can also be performed as an indirect assay, since the paper strips are cut from nitrocellulose paper. In this case the immune components are absorbed by the paper during chromatography. Antigen is then detected with an iodinated second antibody. The indirect immune chromatography assay is particularly useful for identifying different sera that react with the same antigen. Reaction with the first serum before chromatography reduces the amount of antigen available to the second serum following chromatography. In addition to characterizing the immune chromatography procedure, we discuss the possible applications of chromatography assays for the quantitation of other types of molecular binding interactions. (Auth.)

  5. Clinical performance of a new hepatitis B surface antigen quantitative assay with automatic dilution

    Directory of Open Access Journals (Sweden)

    Ta-Wei Liu

    2015-01-01

    Full Text Available Hepatitis B virus surface antigen (HBsAg levels reflect disease status and can predict the clinical response to antiviral treatment; however, the emergence of HBsAg mutant strains has become a challenge. The Abbott HBsAg quantification assay provides enhanced detection of HBsAg and HBsAg mutants. We aimed to evaluate the performance of the Abbott HBsAg quantification assay with automatic sample dilutions (shortened as automatic Architect assay, compared with the Abbott HBsAg quantification assay with manual sample dilutions (shortened as manual Architect assay and the Roche HBsAg quantification assay with automatic sample dilutions (shortened as Elecsys. A total of 130 sera samples obtained from 87 hepatitis B virus (HBV-infected patients were collected to assess the correlation between the automatic and manual Architect assays. Among the 87 patients, 41 provided 42 sera samples to confirm the linearity and reproducibility of the automatic Architect assay, and find out the correlation among the Elecsys and two Architect assays. The coefficients of variation (0.44–9.53% and R2 = 0.996–1, which were both determined using values obtained from the automatic Architect assay, showed good reproducibility and linearity. Results of the two Architect assays demonstrated a feasible correlation (n = 130 samples; R = 0.898, p  0.93 in all cases. In conclusion, the correlation between the automatic and manual dilution Architect assays was feasible, particularly in the HBeAg-negative and low DNA groups. With lower labor costs and less human error than the manual version, the Abbott automatic dilution Architect assay provided a good clinical performance with regard to the HBsAg levels.

  6. Definition of purified enzyme-linked immunosorbent assay antigens from the culture filtrate protein of Mycobacterium bovis by proteomic analysis.

    Science.gov (United States)

    Cho, Yun Sang; Lee, Sang-Eun; Ko, Young Joon; Cho, Donghee; Lee, Hyang Shim; Hwang, Inyeong; Nam, Hyangmi; Heo, Eunjung; Kim, Jong Man; Jung, Sukchan

    2009-01-01

    Enzyme-linked immunosorbent assay (ELISA) has been developed as the ancillary diagnosis of bovine tuberculosis at ante-mortem to overcome the disadvantages of intradermal skin test. In this study, the antigenic proteins were purified, applied to bTB ELISA, and identified through proteomic analysis. Culture filtrate protein of Mycobacterium bovis was fractionated by MonoQ column chromatography, and examined the antigenicity by immunoblotting. The antigenic 20 kDa protein was in-gel digested and identified the antigenome by LTQ mass spectrometer and peptide match fingerprinting, which were MPB64, MPB70, MPB83, Fas, Smc, Nrp, RpoC, Transposase, LeuA, and MtbE. The 20 kDa protein exhibited the highest antigenicity to bTB positive cattle in ELISA and would be useful for bTB serological diagnosis.

  7. Potential radioimmunoassay system for detection of Hanganutziu-Deicher type heterophile antigen(s) and antibodies in tissues and fluids

    Energy Technology Data Exchange (ETDEWEB)

    Mukuria, J C; Naiki, Masaharu; Hashimoto, Masato; Nishiura, Katsumi; Okabe, Masahiro; Kato, Shiro

    1985-06-12

    A relatively simple, specific and sensitive radioimmunoassay system has been developed for the detection of heterophile Hanganutziu-Deicher (H-D) antigen(s) and antibodies. The SVI-labeled H-D antigen-active molecule used for the assay is a bovine erythrocyte major glycoprotein previously found to have a strong H-D antigen potency. Different H-D antigen-active molecules were compared for heterophile H-D antigen potency. Eight different lung cancer tissues were assayed for H-D antigen. The sera from the 8 lung cancer patients were also screened by ELISA and RIA in an attmept to correlate expression of H-D antigen on tissues with elevation of H-D antibodies.

  8. Standardization and validation of a cytometric bead assay to assess antibodies to multiple Plasmodium falciparum recombinant antigens.

    Science.gov (United States)

    Ondigo, Bartholomew N; Park, Gregory S; Gose, Severin O; Ho, Benjamin M; Ochola, Lyticia A; Ayodo, George O; Ofulla, Ayub V; John, Chandy C

    2012-12-21

    Multiplex cytometric bead assay (CBA) have a number of advantages over ELISA for antibody testing, but little information is available on standardization and validation of antibody CBA to multiple Plasmodium falciparum antigens. The present study was set to determine optimal parameters for multiplex testing of antibodies to P. falciparum antigens, and to compare results of multiplex CBA to ELISA. Antibodies to ten recombinant P. falciparum antigens were measured by CBA and ELISA in samples from 30 individuals from a malaria endemic area of Kenya and compared to known positive and negative control plasma samples. Optimal antigen amounts, monoplex vs multiplex testing, plasma dilution, optimal buffer, number of beads required were assessed for CBA testing, and results from CBA vs. ELISA testing were compared. Optimal amounts for CBA antibody testing differed according to antigen. Results for monoplex CBA testing correlated strongly with multiplex testing for all antigens (r = 0.88-0.99, P values from <0.0001 - 0.004), and antibodies to variants of the same antigen were accurately distinguished within a multiplex reaction. Plasma dilutions of 1:100 or 1:200 were optimal for all antigens for CBA testing. Plasma diluted in a buffer containing 0.05% sodium azide, 0.5% polyvinylalcohol, and 0.8% polyvinylpyrrolidone had the lowest background activity. CBA median fluorescence intensity (MFI) values with 1,000 antigen-conjugated beads/well did not differ significantly from MFI with 5,000 beads/well. CBA and ELISA results correlated well for all antigens except apical membrane antigen-1 (AMA-1). CBA testing produced a greater range of values in samples from malaria endemic areas and less background reactivity for blank samples than ELISA. With optimization, CBA may be the preferred method of testing for antibodies to P. falciparum antigens, as CBA can test for antibodies to multiple recombinant antigens from a single plasma sample and produces a greater range of values in

  9. Analysis of hepatitis B surface antigen (HBsAg) using high-sensitivity HBsAg assays in hepatitis B virus carriers in whom HBsAg seroclearance was confirmed by conventional assays.

    Science.gov (United States)

    Ozeki, Itaru; Nakajima, Tomoaki; Suii, Hirokazu; Tatsumi, Ryoji; Yamaguchi, Masakatsu; Kimura, Mutsuumi; Arakawa, Tomohiro; Kuwata, Yasuaki; Ohmura, Takumi; Hige, Shuhei; Karino, Yoshiyasu; Toyota, Joji

    2018-02-01

    We investigated the utility of high-sensitivity hepatitis B surface antigen (HBsAg) assays compared with conventional HBsAg assays. Using serum samples from 114 hepatitis B virus (HBV) carriers in whom HBsAg seroclearance was confirmed by conventional HBsAg assays (cut-off value, 0.05 IU/mL), the amount of HBsAg was re-examined by high-sensitivity HBsAg assays (cut-off value, 0.005 IU/mL). Cases negative for HBsAg in both assays were defined as consistent cases, and cases positive for HBsAg in the high-sensitivity HBsAg assay only were defined as discrepant cases. There were 55 (48.2%) discrepant cases, and the range of HBsAg titers determined by high-sensitivity HBsAg assays was 0.005-0.056 IU/mL. Multivariate analysis showed that the presence of nucleos(t)ide analog therapy, liver cirrhosis, and negative anti-HBs contributed to the discrepancies between the two assays. Cumulative anti-HBs positivity rates among discrepant cases were 12.7%, 17.2%, 38.8%, and 43.9% at baseline, 1 year, 3 years, and 5 years, respectively, whereas the corresponding rates among consistent cases were 50.8%, 56.0%, 61.7%, and 68.0%, respectively. Hepatitis B virus DNA negativity rates were 56.4% and 81.4% at baseline, 51.3% and 83.3% at 1 year, and 36.8% and 95.7% at 3 years, among discrepant and consistent cases, respectively. Hepatitis B surface antigen reversion was observed only in discrepant cases. Re-examination by high-sensitivity HBsAg assays revealed that HBsAg was positive in approximately 50% of cases. Cumulative anti-HBs seroconversion rates and HBV-DNA seroclearance rates were lower in these cases, suggesting a population at risk for HBsAg reversion. © 2017 The Japan Society of Hepatology.

  10. An immunoradiometric assay for procoagulant factor VIII antigen: results in haemophilia, von Willebrand's disease and fetal plasma and serum

    International Nuclear Information System (INIS)

    Peake, I.R.; Bloom, A.L.; Giddings, J.C.; Ludlam, C.A.

    1979-01-01

    An immunoradiometric assay (IRMA) has been developed based on the inhibitor which arose in a polytransfused severe haemophiliac. The two-site IRMA measured antigens closely associated with the procoagulant parts of the factor VIII complex, which are termed FVIIIC antigens or FVIIICAG. FVIIICAG was present in normal plasma and also, at a slightly lower concentration, in normal serum. In 37 patients with haemophilia A, 36 had FVIIICAG levels of less than 10% of the normal plasma pool. In patients with von Willebrand's disease the levels of FVIIIC and FVIIICAG were in good agreement, both before and after treatment with cryoprecipitate or DDAVP. FVIIICAG was relatively stable in plasma at 37 0 C and could also be detected in cord and fetal serum. The assay is of potential value for detecting reduced levels of factor VIII, for carrier detection and for the prenatal diagnosis of haemophilia. (author)

  11. Specific binding-adsorbent assay method and test means

    International Nuclear Information System (INIS)

    1981-01-01

    A description is given of an improved specific binding assay method and test means employing a nonspecific adsorbent for the substance to be determined, particularly hepatitis B surface (HBsub(s)) antigen, in its free state or additionally in the form of its immune complex. The invention is illustrated by 1) the radioimmunoadsorbent assay for HBsub(s) antigen, 2) the radioimmunoadsorbent assay for HBsub(s) antigen in the form of immune complex with antibody, 3) a study of adsorption characteristics of various anion exchange materials for HBsub(s) antigen, 4) the use of hydrophobic adsorbents in a radioimmunoadsorbent assay for HBsub(s) antigen and 5) the radioimmunoadsorbent assay for antibody to HBsub(s) antigen. The advantages of the present method for detecting HBsub(s) antigen compared to previous methods include the manufacturing advantages of eliminating the need for insolubilised anti-HBsub(s) and the advantages of a single incubation step, fewer manipulations, storability of adsorbent materials, increased sensitivity and versatility of detecting HBsub(s) antigen in the form of its immune complex if desired. (U.K.)

  12. Detection of H5 Avian Influenza Viruses by Antigen-Capture Enzyme-Linked Immunosorbent Assay Using H5-Specific Monoclonal Antibody▿

    OpenAIRE

    He, Qigai; Velumani, Sumathy; Du, Qingyun; Lim, Chee Wee; Ng, Fook Kheong; Donis, Ruben; Kwang, Jimmy

    2007-01-01

    The unprecedented spread of highly pathogenic avian influenza virus subtype H5N1 in Asia and Europe is threatening animals and public health systems. Effective diagnosis and control management are needed to control the disease. To this end, we developed a panel of monoclonal antibodies (MAbs) against the H5N1 avian influenza virus (AIV) and implemented an antigen-capture enzyme-linked immunosorbent assay (AC-ELISA) to detect the H5 viral antigen. Mice immunized with denatured hemagglutinin (H...

  13. Short Communication: Comparison of Maxim and Sedia Limiting Antigen Assay Performance for Measuring HIV Incidence.

    Science.gov (United States)

    Schlusser, Katherine E; Konikoff, Jacob; Kirkpatrick, Allison R; Morrison, Charles; Chipato, Tsungai; Chen, Pai-Lien; Munjoma, Marshall; Eshleman, Susan H; Laeyendecker, Oliver

    2017-06-01

    Accurate methods for cross-sectional incidence estimation are needed for HIV prevention research. The Limiting Antigen Avidity (LAg-Avidity) assay has been marketed by two vendors, Maxim Biomedical and Sedia BioSciences Corporation. Performance differences between the two versions of the assay are unknown. We tested a total 1,410 treatment-naive samples with both versions of the assay. The samples came from 176 seroconverters from the Zimbabwe Hormonal Contraception and HIV Study. The correlation between the two versions of the assay was 0.93 for the optical density (OD) and 0.86 for the normalized OD. As the difference was more pronounced for the normalized OD, the difference in assays can be attributed to the calibrators. The mean duration of recent infection (MDRI), the average time individuals infected 1,000 copies/ml. The MDRI was 137 days for Sedia and 157 days for Maxim, with a difference of 20 days (95% CI 11-30). The MDRIs decreased to 102 and 120 days with the inclusion of a viral load cutoff of >1,000 copies/ml. These results imply that use of the Sedia LAg-Avidity will result in estimates of incidence ∼13% lower than those using the Maxim LAg-Avidity.

  14. Scintillation proximity assay

    International Nuclear Information System (INIS)

    Hart, H.

    1980-01-01

    In a method of immunological assay two different classes of particles which interact at short distances to produce characteristic detectable signals are employed in a modification of the usual latex fixation test. In one embodiment an aqueous suspension of antigen coated tritiated latex particles (LH) and antigen coated polystyrene scintillant particles (L*) is employed to assay antibody in the aqueous medium. The amount of (LH) (L*) dimer formation and higher order aggregation induced and therefore the concentration of antibody (or antigen) present which caused the aggregation can be determined by using standard liquid scintillation counting equipment. (author)

  15. Using a genomic assay for the detection of SNPs of Knops blood group antigens leads to the identification of two caucasians homozygous for the SNP associated with the knops SL3 antigen

    DEFF Research Database (Denmark)

    Jakobsen, M. A.; Sprogoe, U.

    2015-01-01

    designed a genomic assay based on sequencing targeting the SNPs underlying the antigens of the Knops system. Study Design/Methods: Samples from a total of 105 blood donors and 2 patients were examined for polymorphisms in CR1 exon 29 by using PCR and subsequent Sanger sequencing. Results......Background/Case Studies: The antigens of the Knops (Kn) blood group system are associated with SNPs located on exon 29 and (to lesser extent) on exon 26 of the complement receptor 1 (CR1) gene. Because of a lack of proper typing antibodies, serologic detection of Kn antigens is not feasible. We....../Findings: With regard to Kn a and b antigens, we found SNP frequencies to be 90.5% for G/G (4681)* associated with Kn(a+b-) and 9.5% for G/A associated with Kn(a+b+). None of the 107 patients/donors were found to be homozygous for A/A associated with Kn(ab+). The frequencies of SNPs associated with the KCAM antigen...

  16. Sensitivity and specificity of tritiated thymidine incorporation and ELISPOT assays in identifying antigen specific T cell immune responses

    Directory of Open Access Journals (Sweden)

    MacLeod Beth

    2007-09-01

    Full Text Available Abstract Background Standardization of cell-based immunologic monitoring is becoming increasingly important as methods for measuring cellular immunity become more complex. We assessed the ability of two commonly used cell-based assays, tritiated thymidine incorporation (proliferation and IFN-gamma ELISPOT, to predict T cell responses to HER-2/neu, tetanus toxoid (tt, and cytomegalovirus (CMV antigens. These antigens were determined to be low (HER-2/neu, moderate (tt, and robustly (CMV immunogenic proteins. Samples from 27 Stage II, III, and IV HER-2/neu positive breast cancer patients, vaccinated against the HER-2/neu protein and tt, were analyzed by tritiated thymidine incorporation and IFN-gamma ELISPOT for T cell response. Results Linear regression analysis indicates that both stimulation index (SI (p = 0.011 and IFN-gamma secreting precursor frequency (p Conclusion These data underscore the importance of taking into consideration the performance characteristics of assays used to measure T cell immunity. This consideration is particularly necessary when determining which method to utilize for assessing responses to immunotherapeutic manipulations in cancer patients.

  17. Whole blood assay to access T cell-immune responses to Mycobacterium tuberculosis antigens in healthy Brazilian individuals

    Directory of Open Access Journals (Sweden)

    Paulo RZ Antas

    2004-02-01

    Full Text Available The production of interferon gamma (IFNgamma guarantees effective T cell-mediated immunity against Mycobacterium tuberculosis infection. In the present study, we simply compare the in vitro immune responses to Mycobacterium antigens in terms of IFNg production in a total of 10 healthy Brazilian volunteers. Whole blood and mononuclear cells were cultivated in parallel with PPD, Ag85B, and M. bovis hsp65, and five-days supernatants were harvested for cytokine detection by ELISA. The inter-assay result was that the overall profile of agreement in response to antigens was highly correlated (r² = 0.9266; p = 0.0102. Potential analysis is in current progress to dictate the usefulness of this method to access the immune responses also in tuberculosis patients and its contacts.

  18. Comparison of three stool antigen assays with the 13C- urea breath test for the primary diagnosis of Helicobacter pylori infection and monitoring treatment outcome.

    LENUS (Irish Health Repository)

    Hooton, Carmel

    2012-02-03

    BACKGROUND: The urea breath test (UBT) is the gold-standard non-invasive test for the detection of Helicobacter pylori infection, however, the lack of availability of the UBT due to the high cost of the test, and in particular the need for expensive analytical instrumentation, limits the usefulness of this method. Stool antigen assays may offer an alternative non-invasive method for the diagnosis of infection. OBJECTIVE: To compare the accuracy of three stool antigen assays (HpSA, IDEIA HpStAR, and ImmunoCard STAT) against the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome. METHODS: A total of 102 patients attending two gastroenterology day-case clinics for the investigation of dyspepsia were included. Each patient provided breath and stool samples for analysis. Patients who tested positive for H. pylori by the validated UBT were prescribed triple therapy and invited to return for repeat breath and stool sample analysis 6 weeks post-treatment. RESULTS: Of the 102 patients tested, 48 were diagnosed with H. pylori infection by the UBT. The HpSA assay interpreted 38 of these as positive (79% sensitive). Of the 54 UBT-negative patients the HpSA assay interpreted all 54 as negative (100% specific). The IDEIA HpStAR assay correctly identified 44 patients as positive (92% sensitive) and 50 as negative (92.5% specific). The ImmunoCard STAT assay interpreted 38 patients as positive (79% sensitive) and 52 as negative (96.3% specific). CONCLUSION: The findings indicate that the IDEIA HpStAR stool antigen kit is the most accurate assay of the three assays evaluated, and possibly represents a viable alternative to the UBT for the primary diagnosis of H. pylori infection and for monitoring treatment outcome.

  19. Statistical prediction of immunity to placental malaria based on multi-assay antibody data for malarial antigens

    DEFF Research Database (Denmark)

    Siriwardhana, Chathura; Fang, Rui; Salanti, Ali

    2017-01-01

    Background Plasmodium falciparum infections are especially severe in pregnant women because infected erythrocytes (IE) express VAR2CSA, a ligand that binds to placental trophoblasts, causing IE to accumulate in the placenta. Resulting inflammation and pathology increases a woman’s risk of anemia...... to 28 malarial antigens and used the data to develop statistical models for predicting if a woman has sufficient immunity to prevent PM. Methods Archival plasma samples from 1377 women were screened in a bead-based multiplex assay for Ab to 17 VAR2CSA-associated antigens (full length VAR2CSA (FV2), DBL...... in the following seven statistical approaches: logistic regression full model, logistic regression reduced model, recursive partitioning, random forests, linear discriminant analysis, quadratic discriminant analysis, and support vector machine. Results The best and simplest model proved to be the logistic...

  20. PCR Assays for Identification of Coccidioides posadasii Based on the Nucleotide Sequence of the Antigen 2/Proline-Rich Antigen

    Science.gov (United States)

    Bialek, Ralf; Kern, Jan; Herrmann, Tanja; Tijerina, Rolando; Ceceñas, Luis; Reischl, Udo; González, Gloria M.

    2004-01-01

    A conventional nested PCR and a real-time LightCycler PCR assay for detection of Coccidioides posadasii DNA were designed and tested in 120 clinical strains. These had been isolated from 114 patients within 10 years in Monterrey, Nuevo Leon, Mexico, known to be endemic for coccidioidomycosis. The gene encoding the specific antigen 2/proline-rich antigen (Ag2/PRA) was used as a target. All strains were correctly identified, whereas DNA from related members of the family Onygenaceae remained negative. Melting curve analysis by LightCycler and sequencing of the 526-bp product of the first PCR demonstrated either 100% identity to the GenBank sequence of the Silveira strain, now known to be C. posadasii (accession number AF013256), or a single silent mutation at position 1228. Length determination of two microsatellite-containing loci (GAC and 621) identified all 120 isolates as C. posadasii. Specific DNA was amplified by conventional nested PCR from three microscopically spherule-positive paraffin-embedded tissue samples, whereas 20 human tissue samples positive for other dimorphic fungi remained negative. Additionally, the safety of each step of a modified commercially available DNA extraction procedure was evaluated by using 10 strains. At least three steps of the protocol were demonstrated to sufficiently kill arthroconidia. This safe procedure is applicable to cultures and to clinical specimens. PMID:14766853

  1. Antigenic determinants and functional domains in core antigen and e antigen from hepatitis B virus

    International Nuclear Information System (INIS)

    Salfeld, J.; Pfaff, E.; Noah, M.; Schaller, H.

    1989-01-01

    The precore/core gene of hepatitis B virus directs the synthesis of two polypeptides, the 21-kilodalton subunit (p21c) forming the viral nucleocapsid (serologically defined as core antigen [HBcAg]) and a secreted processed protein (p17e, serologically defined as HBe antigen [HBeAg]). Although most of their primary amino acid sequences are identical, HBcAg and HBeAg display different antigenic properties that are widely used in hepatitis B virus diagnosis. To locate and to characterize the corresponding determinants, segments of the core gene were expressed in Escherichia coli and probed with a panel of polyclonal or monoclonal antibodies in radioimmunoassays or enzyme-linked immunosorbent assays, Western blots, and competition assays. Three distinct major determinants were characterized. It is postulated that HBcAg and HBeAg share common basic three-dimensional structure exposing the common linear determinant HBe1 but that they differ in the presentation of two conformational determinants that are either introduced (HBc) or masked (HBe2) in the assembled core. The simultaneous presentation of HBe1 and HBc, two distinctly different antigenic determinants with overlapping amino acid sequences, is interpreted to indicate the presence of slightly differently folded, stable conformational states of p21c in the hepatitis virus nucleocapsid

  2. Evaluation of enzyme-linked immunosorbent assays based on monoclonal antibodies for the serology and antigen detection in canine parvovirus infections.

    NARCIS (Netherlands)

    G.F. Rimmelzwaan (Guus); N. Juntti; B. Klingeborn; J. Groen (Jan); F.G.C.M. Uytdehaag (Fons); A.D.M.E. Osterhaus (Albert)

    1990-01-01

    textabstractAn enzyme-linked immunosorbent assay (ELISA) system was developed for the detection of canine parvovirus (CPV) or CPV antigen in dog faeces and two other ELISA systems were developed for the detection of CPV-specific antibodies in dog sera. The ELISA's were based on the use of

  3. Antigen detection systems

    Science.gov (United States)

    Infectious agents or their constituent parts (antigens or nucleic acids) can be detected in fresh, frozen, or fixed tissues or other specimens, using a variety of direct or indirect assays. The assays can be modified to yield the greatest sensitivity and specificity but in most cases a particular m...

  4. Review of Mycobacteriumavium subsp. paratuberculosis antigen candidates with diagnostic potential

    DEFF Research Database (Denmark)

    Mikkelsen, Heidi; Aagaard, Claus; Nielsen, Søren Saxmose

    2011-01-01

    antigens, heat shock antigens and hypothetical antigens. Strategies for evaluation of novel antigen candidates are discussed critically. Relatively few of the described antigens were evaluated for their use in CMI based diagnostic assays and so far, no obvious candidate has been identified...... to development of antibodies and shedding of detectable amounts of MAP. At present, available diagnostic assays are limited by the lack of MAP specific antigens included in these assays resulting in poor specificity. The objective of this review is to provide a systematic overview of diagnostic MAP antigen...... faeces; however, these diagnostic tools are often not applicable until years after infection. Detection of MAP specific cell-mediated immune (CMI) responses can serve as an alternative and be implemented in a diagnostic tool. CMI responses can be measured at an early stage of infection, prior...

  5. Comparison of colorimetric assays with quantitative amino acid analysis for protein quantification of Generalized Modules for Membrane Antigens (GMMA).

    Science.gov (United States)

    Rossi, Omar; Maggiore, Luana; Necchi, Francesca; Koeberling, Oliver; MacLennan, Calman A; Saul, Allan; Gerke, Christiane

    2015-01-01

    Genetically induced outer membrane particles from Gram-negative bacteria, called Generalized Modules for Membrane Antigens (GMMA), are being investigated as vaccines. Rapid methods are required for estimating the protein content for in-process assays during production. Since GMMA are complex biological structures containing lipid and polysaccharide as well as protein, protein determinations are not necessarily straightforward. We compared protein quantification by Bradford, Lowry, and Non-Interfering assays using bovine serum albumin (BSA) as standard with quantitative amino acid (AA) analysis, the most accurate currently available method for protein quantification. The Lowry assay has the lowest inter- and intra-assay variation and gives the best linearity between protein amount and absorbance. In all three assays, the color yield (optical density per mass of protein) of GMMA was markedly different from that of BSA with a ratio of approximately 4 for the Bradford assay, and highly variable between different GMMA; and approximately 0.7 for the Lowry and Non-Interfering assays, highlighting the need for calibrating the standard used in the colorimetric assay against GMMA quantified by AA analysis. In terms of a combination of ease, reproducibility, and proportionality of protein measurement, and comparability between samples, the Lowry assay was superior to Bradford and Non-Interfering assays for GMMA quantification.

  6. Carcinoembryonic antigen (CEA)

    International Nuclear Information System (INIS)

    Ephraim, K.H.; Cox, P.H.; Hamer, C.J.A. v.d.; Berends, W.; Delhez, H.

    1977-01-01

    The carcinoembryonic antigen (CEA) is a complex of antigen determinants and also the carrier of these determinants. Chemically it is a glycoprotein. Its occurrence in blood serum or urine is correlated with malignant disease. Several radioimmunoassays (RIA) have been developed, one by Hoffmann-Laroche and one by the Rotterdam Radiotherapeutic Institute. Both methods and the Hoffmann assay kit are tested. Specifications are given for isolation of the antigen, preparation of the antiserum, and the execution of the RIA. Biochemical and clinical aspects are discussed

  7. Detection of Giardia duodenalis antigen in human fecal eluates by enzyme-linked immunosorbent assay using polyclonal antibodies

    Directory of Open Access Journals (Sweden)

    Sofía Duque-Beltrán

    2002-12-01

    Full Text Available The present study developed and standardized an enzime-linked immunosorbent assay (ELISA to detect Giardia antigen in feces using rabbit polyclonal antibodies. Giardia cysts were purified from human fecal samples by sucrose and percoll gradients. Gerbils (Meriones unguiculatus were infected to obtain trophozoites. Rabbits were inoculated with either cyst or trophozoite antigens of 14 Colombian Giardia isolates to develop antibodies against the respective stages. The IgG anti-Giardia were purified by sequential caprylic acid and ammonium sulfate precipitation. A portion of these polyclonal antibodies was linked to alkaline phosphatase (conjugate. One hundred and ninety six samples of human feces, from different patients, were tested by parasitologic diagnosis: 69 were positive for Giardia cysts, 56 had no Giardia parasites, and 71 revealed parasites other than Giardia. The optimal concentration of polyclonal antibodies for antigen capture was 40 µg/ml and the optimal conjugate dilution was 1:100. The absorbance cut-off value was 0.24. The parameters of the ELISA test for Giardia antigen detection were: sensitivity, 100% (95% CI: 93.4-100%; specificity, 95% (95% CI: 88.6-97.6%; positive predictive value, 91% (95% CI: 81.4-95.9%; and negative predictive value, 100% (95% CI: 96.1-100%. This ELISA will improve the diagnosis of Giardia infections in Colombia and will be useful in following patients after treatment.

  8. Bayesian nonparametric clustering in phylogenetics: modeling antigenic evolution in influenza.

    Science.gov (United States)

    Cybis, Gabriela B; Sinsheimer, Janet S; Bedford, Trevor; Rambaut, Andrew; Lemey, Philippe; Suchard, Marc A

    2018-01-30

    Influenza is responsible for up to 500,000 deaths every year, and antigenic variability represents much of its epidemiological burden. To visualize antigenic differences across many viral strains, antigenic cartography methods use multidimensional scaling on binding assay data to map influenza antigenicity onto a low-dimensional space. Analysis of such assay data ideally leads to natural clustering of influenza strains of similar antigenicity that correlate with sequence evolution. To understand the dynamics of these antigenic groups, we present a framework that jointly models genetic and antigenic evolution by combining multidimensional scaling of binding assay data, Bayesian phylogenetic machinery and nonparametric clustering methods. We propose a phylogenetic Chinese restaurant process that extends the current process to incorporate the phylogenetic dependency structure between strains in the modeling of antigenic clusters. With this method, we are able to use the genetic information to better understand the evolution of antigenicity throughout epidemics, as shown in applications of this model to H1N1 influenza. Copyright © 2017 John Wiley & Sons, Ltd. Copyright © 2017 John Wiley & Sons, Ltd.

  9. [Fundamental and clinical evaluation of hepatitis B virus core-related antigen assay by LUMIPULSE f].

    Science.gov (United States)

    Tanaka, Yasuhito; Takagi, Kazumi; Hiramatsu, Kumiko; Naganuma, Hatsue; Iida, Takayasu; Takasaka, Yoshimitsu; Mizokami, Masashi

    2006-07-01

    A sensitive chemiluminescence enzyme immunoassay (CLEIA) has been developed for hepatitis B virus (HBV) core-related antigens (HBcrAg) detection. The HBcrAg is designated as the precore/core gene products including HBeAg. The aim of this study is to evaluate reproducibility of HBcrAg and correlation with HBV-DNA in serum using the automatic LUMIPULSE f to estimate an assay suitable for general laboratory use. In this study, we demonstrated that HBcrAg assay had highly intra-assay reproducible [coefficients of variation(CVs); 2.8-5.2%] and inter-assay reproducible [CVs; 3.9-9.1%]. When the cutoff value was tentatively set at 1 kU/ml, all healthy controls (HBsAg/HBV-DNA negative; n=100) and anti-HCV antibody-positive (n=50) sera were identified as negative. The assay showed a detection limit of 0.5 kU/ml using four serially diluted HBV high-titer sera, indicating higher sensitivity than HBV-DNA (transcription-mediated amplification). The HBcrAg concentration correlated positively with serum HBV-DNA (n=125, r = 0.860, p < 0.0001) regardless of HBeAg, although the HBcrAg levels were higher in HBeAg-positive group than in HBeAg-negative group. In the natural course of HBV infection, the HBcrAg concentration usually changed in accordance with HBV-DNA levels, however during lamivudine therapy the change of HBcrAg was more gradual than that of HBV-DNA. In conclusion, HBcrAg concentration provides a reflection of HBV virus load equivalent to HBV-DNA level, and the assay therefore offers a simple method for monitoring hepatitis B patients.

  10. Evaluation of a Direct Immunofluorescent Assay and/or Conjunctival Cytology for Detection of Canine Distemper Virus Antigen.

    Science.gov (United States)

    Athanasiou, Labrini V; Kantere, Maria C; Kyriakis, Constantinos S; Pardali, Dimitra; Adamama Moraitou, Katerina; Polizopoulou, Zoe S

    2018-04-01

    Canine distemper is a common and potentially lethal multisystemic disease caused by the Canine distemper virus (CDV). We evaluated the diagnostic performance of direct immunofluorescent assay (FA) and cytology to detect CDV antigen in conjunctival cells compared with an established polymerase chain reaction (PCR) detection assay used as a gold standard for CDV diagnosis. Samples were collected from 57 young dogs presenting with central nervous system signs compatible with distemper disease. Exfoliative epithelial cells were collected from the right and left conjunctiva of each animal using nylon-bristled cytobrushes for cytology and cotton swabs for FA and PCR. For the direct FA, samples were stained with anti-CDV polyclonal antiserum conjugated to fluorescein isothiocyanate and imaged using a fluorescent microscope. Out of 57 dogs tested, 19 were PCR positive (15 positive in direct FA and 4 positive in cytology, including one that was negative by PCR), whereas 37 dogs were negative in all methods. A good agreement was observed between the FA and PCR, with a κ-value of 0.833 (95% CI: 0.678-0.989). Meanwhile, there was poor agreement between cytology and PCR (κ-value of 0.164; 95% CI: -0.045 to 0.373) and a fair agreement between FA and cytology (κ-value of 0.231; 95% CI: -0.026 to 0.487). Our results indicated a poor performance of cytology for the detection of CDV antigen. In contrast, FA is a 100% specific and an adequately sensitive assay (sensitivity: 78.95%, negative likelihood ratio: 0.21, 95% CI: 0.09-0.50) for antemortem diagnosis of canine distemper.

  11. Multiplex assay (Mikrogen recomBead) for detection of serum IgG and IgM antibodies to 13 recombinant antigens of Borrelia burgdorferi sensu lato in patients with neuroborreliosis

    DEFF Research Database (Denmark)

    Dessau, Ram Benny; Møller, Jens K.; Kolmos, Birte

    2015-01-01

    A multiplex-bead-based assay for the detection of serum antibodies to Borrelia burgdorferi sensu lato was evaluated. The assay contained 13 different antigens in both the IgG and the IgM assay; thus, a total of 26 measurement results were available from each sample. A total of 49 Danish patients......, the construction of a diagnostic score, evaluation of the scoring method using an independent dataset and an assessment of the analytical quality of the multiplex assay. The VlsE IgG had the highest diagnostic value with an AUC (area under the curve) of 96% on the receiver operating characteristic curve. The Osp......C IgM had AUCs just above 80%. All the other antigens had both low quantitative reactivity and lower contrast in the patients with LNB compared to controls. The diagnostic value of the assay may be improved by using a logistic model giving a sensitivity of 90 and 79% for the specificities at 92 and 98...

  12. Enzyme linked immunosorbent assay for detecting antibody to Trichomonas vaginalis: use of whole cells and aqueous extract as antigen.

    Science.gov (United States)

    Alderete, J F

    1984-06-01

    An enzyme linked immunosorbent assay (ELISA) for detecting antibody to antigenic Trichomonas vaginalis macromolecules has been identified using whole cells or an aqueous protein extract as antigen. The test was developed under optimum conditions using serum samples from experimental animals. The sensitivity of the ELISA was equal to or greater than that obtained by radioimmunoprecipitation and electrophoresis-fluorography techniques. The ELISA was capable of assessing antibody responses during the development of lesions in animals inoculated subcutaneously and it reproducibly measured the individual classes immunoglobulins directed at T vaginalis. The colorimetric assay was also suitable for showing cross reactivity between trichomonal species as well as between different strains of T vaginalis. Conditions established for monitoring antibody to trichomanads in immunised rabbits or infected mice were equally effective for human materials, such as serum or vaginal washes. Serum from experimental animals or infected people showed high concentrations of IgG, IgA, and IgM antibody to trichomonads. Only antibodies of the IgG and IgA class were detected in vaginal washes from women with acute trichomoniasis. No IgE antibody to trichomonads was found under a variety of conditions in serum samples from patients or experimental animals.

  13. Monoclonal antibodies to Nocardia asteroides and Nocardia brasiliensis antigens.

    OpenAIRE

    Jiménez, T; Díaz, A M; Zlotnik, H

    1990-01-01

    Nocardia asteroides and Nocardia brasiliensis whole-cell extracts were used as antigens to generate monoclonal antibodies (MAbs). Six stable hybrid cell lines secreting anti-Nocardia spp. MAbs were obtained. These were characterized by enzyme-linked immunosorbent assay, Western blot (immunoblot), and immunofluorescence assay. Although all the MAbs exhibited different degrees of cross-reactivity with N. asteroides and N. brasiliensis antigens as well as with culture-filtrate antigens from Myco...

  14. Development of a Luminex Bead Based Assay for Diagnosis of Toxocariasis Using Recombinant Antigens Tc-CTL-1 and Tc-TES-26.

    Directory of Open Access Journals (Sweden)

    John P Anderson

    Full Text Available The clinical spectrum of human disease caused by the roundworms Toxocara canis and Toxocara cati ranges from visceral and ocular larva migrans to covert toxocariasis. The parasite is not typically recovered in affected tissues, so detection of parasite-specific antibodies is usually necessary for establishing a diagnosis. The most reliable immunodiagnostic methods use the Toxocara excretory-secretory antigens (TES-Ag in ELISA formats to detect Toxocara-specific antibodies. To eliminate the need for native parasite materials, we identified and purified immunodiagnostic antigens using 2D gel electrophoresis followed by electrospray ionization mass spectrometry. Three predominant immunoreactive proteins were found in the TES; all three had been previously described in the literature: Tc-CTL-1, Tc-TES-26, and Tc-MUC-3. We generated Escherichia coli expressed recombinant proteins for evaluation in Luminex based immunoassays. We were unable to produce a functional assay with the Tc-MUC-3 recombinant protein. Tc-CTL-1 and Tc-TES-26 were successfully coupled and tested using defined serum batteries. The use of both proteins together generated better results than if the proteins were used individually. The sensitivity and specificity of the assay for detecting visceral larval migrans using Tc-CTL-1 plus Tc-TES-26 was 99% and 94%, respectively; the sensitivity for detecting ocular larval migrans was 64%. The combined performance of the new assay was superior to the currently available EIA and could potentially be employed to replace current assays that rely on native TES-Ag.

  15. Comparison of Colorimetric Assays with Quantitative Amino Acid Analysis for Protein Quantification of Generalized Modules for Membrane Antigens (GMMA)

    OpenAIRE

    Rossi, Omar; Maggiore, Luana; Necchi, Francesca; Koeberling, Oliver; MacLennan, Calman A.; Saul, Allan; Gerke, Christiane

    2014-01-01

    Genetically induced outer membrane particles from Gram-negative bacteria, called Generalized Modules for Membrane Antigens (GMMA), are being investigated as vaccines. Rapid methods are required for estimating the protein content for in-process assays during production. Since GMMA are complex biological structures containing lipid and polysaccharide as well as protein, protein determinations are not necessarily straightforward. We compared protein quantification by Bradford, Lowry, and Non-Int...

  16. Antigenic determinants of prostate-specific antigen (PSA) and development of assays specific for different forms of PSA.

    OpenAIRE

    Nilsson, O.; Peter, A.; Andersson, I.; Nilsson, K.; Grundstr?m, B.; Karlsson, B.

    1997-01-01

    Monoclonal antibodies were raised against prostate-specific antigen (PSA) by immunization with purified free PSA, i.e. not in complex with any protease inhibitor (F-PSA) and PSA in complex with alpha1-anti-chymotrypsin (PSA-ACT). Epitope mapping of PSA using the established monoclonal antibody revealed a complex pattern of independent and partly overlapping antigenic domains in the PSA molecule. Four independent antigenic domains and at least three partly overlapping domains were exposed both...

  17. Benefit of hepatitis C virus core antigen assay in prediction of therapeutic response to interferon and ribavirin combination therapy.

    Science.gov (United States)

    Takahashi, Masahiko; Saito, Hidetsugu; Higashimoto, Makiko; Atsukawa, Kazuhiro; Ishii, Hiromasa

    2005-01-01

    A highly sensitive second-generation hepatitis C virus (HCV) core antigen assay has recently been developed. We compared viral disappearance and first-phase kinetics between commercially available core antigen (Ag) assays, Lumipulse Ortho HCV Ag (Lumipulse-Ag), and a quantitative HCV RNA PCR assay, Cobas Amplicor HCV Monitor test, version 2 (Amplicor M), to estimate the predictive benefit of a sustained viral response (SVR) and non-SVR in 44 genotype 1b patients treated with interferon (IFN) and ribavirin. HCV core Ag negativity could predict SVR on day 1 (sensitivity = 100%, specificity = 85.0%, accuracy = 86.4%), whereas RNA negativity could predict SVR on day 7 (sensitivity = 100%, specificity = 87.2%, accuracy = 88.6%). None of the patients who had detectable serum core Ag or RNA on day 14 achieved SVR (specificity = 100%). The predictive accuracy on day 14 was higher by RNA negativity (93.2%) than that by core Ag negativity (75.0%). The combined predictive criterion of both viral load decline during the first 24 h and basal viral load was also predictive for SVR; the sensitivities of Lumipulse-Ag and Amplicor-M were 45.5 and 47.6%, respectively, and the specificity was 100%. Amplicor-M had better predictive accuracy than Lumipulse-Ag in 2-week disappearance tests because it had better sensitivity. On the other hand, estimates of kinetic parameters were similar regardless of the detection method. Although the correlations between Lumipulse-Ag and Amplicor-M were good both before and 24 h after IFN administration, HCV core Ag seemed to be relatively lower 24 h after IFN administration than before administration. Lumipulse-Ag seems to be useful for detecting the HCV concentration during IFN therapy; however, we still need to understand the characteristics of the assay.

  18. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies; Assay development and evaluation in blood transfusion practice

    Energy Technology Data Exchange (ETDEWEB)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J. (Medical School, Manchester (United Kingdom). Department of Medical microbiology, Virology Unit); Morell, G. (Regional Blood Transfusion Centre, manchester (United Kingdom))

    1990-03-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 (human cytomegalovirus (CMV)) has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab.

  19. Comparison of antigen-specific T-cell responses of tuberculosis patients using complex or single antigens of Mycobacterium tuberculosis

    DEFF Research Database (Denmark)

    Mustafa, A S; Amoudy, H A; Wiker, H G

    1998-01-01

    GroES, rPstS, rGroEL and rDnaK) antigens of Mycobacterium tuberculosis. The responses of PBMC to these defined antigens were compared with the corresponding results obtained with complex antigens, such as whole-cell M. tuberculosis, M. tuberculosis culture filtrate (MT-CF) and cell wall antigens, as well...... as the vaccine strain, Mycobacterium bovis bacillus Calmette-Guerin (BCG). In addition, M. tuberculosis and MT-CF-induced T-cell lines were tested in the same assays against the panel of purified and complex antigens. The compiled data from PBMC and T-cell lines tested for antigen-induced proliferation and IFN...

  20. Assessment of Dextran Antigenicity of Intravenous Iron Preparations with Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Neiser, Susann; Koskenkorva, Taija S; Schwarz, Katrin; Wilhelm, Maria; Burckhardt, Susanna

    2016-07-21

    Intravenous iron preparations are typically classified as non-dextran-based or dextran/dextran-based complexes. The carbohydrate shell for each of these preparations is unique and is key in determining the various physicochemical properties, the metabolic pathway, and the immunogenicity of the iron-carbohydrate complex. As intravenous dextran can cause severe, antibody-mediated dextran-induced anaphylactic reactions (DIAR), the purpose of this study was to explore the potential of various intravenous iron preparations, non-dextran-based or dextran/dextran-based, to induce these reactions. An IgG-isotype mouse monoclonal anti-dextran antibody (5E7H3) and an enzyme-linked immunosorbent assay (ELISA) were developed to investigate the dextran antigenicity of low molecular weight iron dextran, ferumoxytol, iron isomaltoside 1000, ferric gluconate, iron sucrose and ferric carboxymaltose, as well as isomaltoside 1000, the isolated carbohydrate component of iron isomaltoside 1000. Low molecular weight iron dextran, as well as dextran-based ferumoxytol and iron isomaltoside 1000, reacted with 5E7H3, whereas ferric carboxymaltose, iron sucrose, sodium ferric gluconate, and isolated isomaltoside 1000 did not. Consistent results were obtained with reverse single radial immunodiffusion assay. The results strongly support the hypothesis that, while the carbohydrate alone (isomaltoside 1000) does not form immune complexes with anti-dextran antibodies, iron isomaltoside 1000 complex reacts with anti-dextran antibodies by forming multivalent immune complexes. Moreover, non-dextran based preparations, such as iron sucrose and ferric carboxymaltose, do not react with anti-dextran antibodies. This assay allows to assess the theoretical possibility of a substance to induce antibody-mediated DIARs. Nevertheless, as this is only one possible mechanism that may cause a hypersensitivity reaction, a broader set of assays will be required to get an understanding of the mechanisms that may

  1. Screening for simian foamy virus infection by using a combined antigen Western blot assay: evidence for a wide distribution among Old World primates and identification of four new divergent viruses

    International Nuclear Information System (INIS)

    Hussain, Althaf I.; Shanmugam, Vedapuri; Bhullar, Vinod B.; Beer, Brigitte E.; Vallet, Dominique; Gautier-Hion, Annie; Wolfe, Nathan D.; Karesh, William B.; Kilbourn, Annelisa M.; Tooze, Zeena; Heneine, Walid; Switzer, William M.

    2003-01-01

    Simian foamy viruses (SFVs) belong to a genetically and antigenically diverse class of retroviruses that naturally infect a wide range of nonhuman primates (NHPs) and can also be transmitted to humans occupationally exposed to NHPs. Current serologic detection of SFV infection requires separate Western blot (WB) testing by using two different SFV antigens [SFV AGM (African green monkey) and SFV CPZ (chimpanzee)]. However, this method is labor intensive and validation is limited to only small numbers of NHPs. To facilitate serologic SFV testing, we developed a WB assay that combines antigens from both SFV AGM and SFV CPZ . The combined-antigen WB (CA-WB) assay was validated with 145 serum samples from 129 NHPs (32 African and Asian species) and 16 humans, all with known SFV infection status determined by PCR. Concordant CA-WB results were obtained for all 145 PCR-positive or -negative primate and human specimens, giving the assay a 100% sensitivity and specificity. In addition, no reactivity was observed in sera from persons positive for human immunodeficiency virus or human T cell lymphotropic virus (HIV/HTLV) (n = 25) or HIV/HTLV-negative U.S. blood donors (n = 100). Using the CA-WB assay, we screened 360 sera from 43 Old World primate species and found an SFV prevalence of about 68% in both African and Asian primates. We also isolated SFV from the blood of four seropositive primates (Allenopithecus nigroviridis, Trachypithecus francoisi, Hylobates pileatus, and H. leucogenys) not previously known to be infected with SFV. Phylogenetic analysis of integrase sequences from these isolates confirmed that all four SFVs represent new, distinct, and highly divergent lineages. These results demonstrate the ability of the CA-WB assay to detect infection in a large number of NHP species, including previously uncharacterized infections with divergent SFVs

  2. Evaluation of Enzyme-Linked Immunosorbent Assay for Diagnosis of Post-Kala-Azar Dermal Leishmaniasis with Crude or Recombinant k39 Antigen

    Science.gov (United States)

    Salotra, P.; Sreenivas, G.; Nasim, A. A.; Subba Raju, B. V.; Ramesh, V.

    2002-01-01

    The diagnosis of post-kala-azar dermal leishmaniasis (PKDL), a dermatosis that provides the only known reservoir for the parasite Leishmania donovani in India, remains a problem. Timely recognition and treatment of PKDL would contribute significantly to the control of kala-azar. We evaluated here the potential of the enzyme-linked immunosorbent assay (ELISA) as a diagnostic tool for PKDL. Antigen prepared from promastigotes and axenic amastigotes with parasite isolates that were derived from skin lesions of a PKDL patient gave sensitivities of 86.36 and 92%, respectively, in the 88 PKDL cases examined. The specificity of the ELISA test was examined by testing groups of patients with other skin disorders (leprosy and vitiligo) or coendemic infections (malaria and tuberculosis), as well as healthy controls from areas where this disease is endemic or is not endemic. A false-positive reaction was obtained in 14 of 144 (9.8%) of the controls with the promastigote antigen and in 14 of 145 (9.7%) of the controls with the amastigote antigen. Evaluation of the serodiagnostic potential of recombinant k39 by ELISA revealed a higher sensitivity (94.5%) and specificity (93.7%) compared to the other two antigens used. The data demonstrate that ELISA with crude or recombinant antigen k39 provides a relatively simple and less-invasive test for the reliable diagnosis of PKDL. PMID:11874880

  3. Inaccuracy of Enzyme-Linked Immunosorbent Assay Using Soluble and Recombinant Antigens to Detect Asymptomatic Infection by Leishmania infantum

    Science.gov (United States)

    Moreno, Elizabeth Castro; Gonçalves, Andréa Vieira; Chaves, Anderson Vieira; Melo, Maria Norma; Lambertucci, José Roberto; Andrade, Antero Silva Ribeiro; Negrão-Corrêa, Deborah; Antunes, Carlos Mauricio de Figueiredo; Carneiro, Mariângela

    2009-01-01

    Background One of the most important drawbacks in visceral leishmaniasis (VL) population studies is the difficulty of diagnosing asymptomatic carriers. The aim of this study, conducted in an urban area in the Southeast of Brazil, was to evaluate the performance of serology to identify asymptomatic VL infection in participants selected from a cohort with a two-year follow-up period. Methodology Blood samples were collected in 2001 from 136 cohort participants (97 positive and 39 negatives, PCR/hybridization carried out in 1999). They were clinically evaluated and none had progressed to disease from their asymptomatic state. As controls, blood samples from 22 control individuals and 8 patients with kala-azar were collected. Two molecular biology techniques (reference tests) were performed: PCR with Leishmania-generic primer followed by hybridization using L. infantum probe, and PCR with specific primer to L. donovani complex. Plasma samples were tested by ELISA using three different antigens: L. infantum and L. amazonensis crude antigens, and rK39 recombinant protein. Accuracy of the serological tests was evaluated using sensitivity, specificity, likelihood ratio and ROC curve. Findings The presence of Leishmania was confirmed, by molecular techniques, in all kala-azar patients and in 117 (86%) of the 136 cohort participants. Kala-azar patients showed high reactivity in ELISAs, whereas asymptomatic individuals presented low reactivity against the antigens tested. When compared to molecular techniques, the L. amazonensis and L. infantum antigens showed higher sensitivity (49.6% and 41.0%, respectively) than rK39 (26.5%); however, the specificity of rK39 was higher (73.7%) than L. amazonensis (52.6%) and L. infantum antigens (36.8%). Moreover, there was low agreement among the different antigens used (kappa<0.10). Conclusions Serological tests were inaccurate for diagnosing asymptomatic infections compared to molecular methods; this could lead to misclassification bias

  4. Antigen spot test (AST): a highly sensitive assay for the detection of antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Herbrink, P; van Bussel, F J; Warnaar, S O [Rijksuniversiteit Leiden (Netherlands)

    1982-02-12

    A method is described for detection of antibodies by means of nitrocellulose or diazobenzyloxymethyl (DBM) paper on which various antigens have been spotted. The sensitivity of this antigen spot test (AST) is comparable with that of RIA and ELISA. The method requires only nanogram amounts of antigen. Since a variety of antigens can be spotted on a single piece of nitrocellulose or DBM paper, this antigen spot test is especially useful for specificity controls on antibodies.

  5. Influence of various desinfectants on the radioimmuno-assay for Australia antigen

    International Nuclear Information System (INIS)

    Bernhard, U.

    1979-01-01

    At normal room temperature dilution series were produced out of pooled serum, serum previously treated with UV irradiation and beta propiolacton, and serum of patients with hepatitis type B and various desinfectants. After differing incubation times the Australia antigen titre was measured in the radioimmunoassay. Electronmicroscopic examinations should detect possible morphologic changes of the Dane particles. The counts/min. measured for Australia antigen after an incubation with aldehyde-containing preparations, are below the limit value with serum treated previously with UV light and beta propiolacton; in negative Australia-antigen-positive serum the counts/min. are close to the limit value. The antigenity is clearly reduced. The comparison with an insulin containing serum showed that also the radioimmunoassay was influenced by the aldehyde. A direct influence of the aldehydes on the protein seems to be possible. From this results that the radioimmunoassay for Australia antigen cannot be used as the exclusive method for measuring the efficacy of desinfectants compared to Dane particles. The morphologic changes of the Dane particles observed in the electronic microscope confirm the supposition that the desinfectants influence the hepatitis viruses. (orig./MG) [de

  6. Direct Competitive Enzyme-Linked Immunosorbent Assay (ELISA).

    Science.gov (United States)

    Kohl, Thomas O; Ascoli, Carl A

    2017-07-05

    The competitive enzyme-linked immunosorbent assay (ELISA) (cELISA; also called an inhibition ELISA) is designed so that purified antigen competes with antigen in the test sample for binding to an antibody that has been immobilized in microtiter plate wells. The same concept works if the immobilized molecule is antigen and the competing molecules are purified labeled antibody versus antibody in a test sample. Direct cELISAs incorporate labeled antigen or antibody, whereas indirect assay configurations use reporter-labeled secondary antibodies. The cELISA is very useful for determining the concentration of small-molecule antigens in complex sample mixtures. In the direct cELISA, antigen-specific capture antibody is adsorbed onto the microtiter plate before incubation with either known standards or unknown test samples. Enzyme-linked antigen (i.e., labeled antigen) is also added, which can bind to the capture antibody only when the antibody's binding site is not occupied by either the antigen standard or antigen in the test samples. Unbound labeled and unlabeled antigens are washed away and substrate is added. The amount of antigen in the standard or the test sample determines the amount of reporter-labeled antigen bound to antibody, yielding a signal that is inversely proportional to antigen concentration within the sample. Thus, the higher the antigen concentration in the test sample, the less labeled antigen is bound to the capture antibody, and hence the weaker is the resultant signal. © 2017 Cold Spring Harbor Laboratory Press.

  7. Toxoplasma gondii: II. Tachyzoite antigenic characterization of eigth strains

    Directory of Open Access Journals (Sweden)

    Regina Mitsuka

    1998-01-01

    Full Text Available Eight Toxoplasma gondii strains were analyzed using ELISA and Western blot techniques, in order to demonstrate possible immunological differences. The analyzed strains were: LIV IV, LIV V and S 11 isolated from swine, RH and VPS from a human being, AS 28 from a wild mouse, HV III from a dog and CN from a cat. With the ELISA assay the eight strains showed similar reactivity with homologous and heterologous sera. The antigenic suspension, consisting of total cellular extract of tachyzoites, was effective in the indirect ELISA assay, with the positive sera reacting strongly and the negative not reacting with the antigens. The Western blot analysis showed that the T. gondii strains have similar antigenic profiles with a few variations. Three bands were observed in all strains: one of about 33 kDa (p33, another of 54 kDa (p54 and a third one of 66 kDa (p66. The HV III strain, isolated from a dog, did not show three antigens (50, 70 and 75 kDa that were present in the others. However, this difference was not detected by the ELISA assay. Only two antigens (62 kDa of the CN and 67 kDa of the LIV IV were strain-specific antigens.

  8. Antigenic relatedness of primate procollagens as determined by a competitive radioimmunoassay

    International Nuclear Information System (INIS)

    Taubman, M.B.; Goldberg, B.

    1978-01-01

    A radioimmunoassay specific for the nonhelical carboxy terminal portion of human type I procollagen was used to study the antigenic relatedness of primate procollagens. The assay identified reactive antigen in primate sera and in the media of primate fibroblast cultures. The displacement curves generated in the assay indicated that human and ape type I procollagens have antigenically identical carboxy terminal determinants which are partially cross-reactive with those from Old and New World monkeys. (author)

  9. Standardization of micro-enzyme-linked immunosorbent assay (ELISA) and Western blot for detection of Trypanosoma cruzi antibodies using extracts from Mexican strains as antigens.

    Science.gov (United States)

    Sánchez, B; Monteón, V; Reyes, P A; Espinoza, B

    2001-01-01

    This report describes two assays for the detection of anti-Trypanosoma cruzi antibodies using Mexican strains of the parasite and the concordance with two assays previously evaluated at the Instituto Nacional de Cardiología Ignacio Chávez in Mexico City. Micro-enzyme-linked immunosorbent assay (ELISA) and Western blot were used for the detection of T. cruzi antibodies with a total extract of epimastigote from Ninoa and Queretaro, which are Mexican strains of T. cruzi. To standardize these methods, a total of 246 serum samples was used. In addition, sera from six confirmed Mexican chronic individuals in the asymptomatic phase were also used for comparison with the Argentinean antigen. ELISA was 100% specific in that no false positive results were found with sera of both healthy individuals and non-Chagasic cardiopaths. Sera from individuals infected with Leishmania sp. showed approximately 16% of cross-reaction with ELISA. The test showed a positive predictive value of 90% and a negative predictive value of 100%. Western blot was also a highly sensitive test for detecting chronic Chagasic symptomatic patients from Mexico because no false negative results were obtained. Furthermore, it was possible to use Western blot to detect seven immunodominant antigens of approximately 30, 32, 40, 42, 65, 70, and 83 kDa. Concordance with two previous standardized tests at the Instituto Nacional de Cardiología showed a Kappa index of 0.96, indicating high concordance between the results obtained at these two laboratories. Finally, ELISA using Ninoa antigen extract was more sensitive than ELISA with an Argentinean extract, which failed to detect individuals in the chronic asymptomatic phase (undetermined phase) of infection. This study indicates that ELISA and Western blot using Ninoa and/or Queretaro extracts of T. cruzi as antigens are useful tools in the detection of individuals who have been exposed to T. cruzi both in the undetermined/asymptomatic and symptomatic phases

  10. [Improvement of sensitivity in the second generation HCV core antigen assay by a novel concentration method using polyethylene glycol (PEG)].

    Science.gov (United States)

    Higashimoto, Makiko; Takahashi, Masahiko; Jokyu, Ritsuko; Syundou, Hiromi; Saito, Hidetsugu

    2007-11-01

    A HCV core antigen (Ag) detection assay system, Lumipulse Ortho HCV Ag has been developed and is commercially available in Japan with a lower detection level limit of 50 fmol/l, which is equivalent to 20 KIU/ml in PCR quantitative assay. HCV core Ag assay has an advantage of broader dynamic range compared with PCR assay, however the sensitivity is lower than PCR. We developed a novel HCV core Ag concentration method using polyethylene glycol (PEG), which can improve the sensitivity five times better than the original assay. The reproducibility was examined by consecutive five-time measurement of HCV patients serum, in which the results of HCV core Ag original and concentrated method were 56.8 +/- 8.1 fmol/l (mean +/- SD), CV 14.2% and 322.9 +/- 45.5 fmol/l CV 14.0%, respectively. The assay results of HCV negative samples in original HCV core Ag were all 0.1 fmol/l and the results were same even in the concentration method. The results of concentration method were 5.7 times higher than original assay, which was almost equal to theoretical rate as expected. The assay results of serially diluted samples were also as same as expected data in both original and concentration assay. We confirmed that the sensitivity of HCV core Ag concentration method had almost as same sensitivity as PCR high range assay in the competitive assay study using the serially monitored samples of five HCV patients during interferon therapy. A novel concentration method using PEG in HCV core Ag assay system seems to be useful for assessing and monitoring interferon treatment for HCV.

  11. Evaluation of Antigen-Specific IgM and IgG Production during an In Vitro Peripheral Blood Mononuclear Cell Culture Assay

    Directory of Open Access Journals (Sweden)

    Yoshiko Matsuda

    2017-07-01

    Full Text Available The recent attention given to diseases associated with memory B-cell (mBC-produced antibodies (Abs suggests the need for a similar in vitro assay to evaluate the functions of mBCs. Here, we cultured peripheral blood mononuclear cells (PBMCs with the intent to collect mBC-derived Abs in vitro and maintain their cell–cell contact-dependent interactions with helper T-cells. PBMCs were cultured with interleukin (IL-21, CpG-oligodeoxynucleotides (ODN, phorbol myristate acetate (PMA, and phytohemagglutinin/leucoagglutinin (PHA-L in 24-well flat-bottom plates (5 × 105 cells/well. A culture supernatant analysis of PBMCs from healthy donors (n = 10 indicated that antigen-specific IgM Ab levels in a PBMC culture supernatant might be better able to demonstrate the antigen sensitization status in a smaller peripheral blood sample, compared to IgG because Epstein–Barr virus-specific IgM mBCs circulate peripherally at a significantly higher frequency once antiviral humoral immunity has stabilized. Thus, our in vitro assay demonstrated the potential significance of antigen-specific IgM Ab production in the culture supernatants. Furthermore, an analysis of cultured PBMCs from allograft kidney recipients (n = 16 sensitized with de novo donor-specific human leukocyte antigen (HLA-specific Abs (DSAs showed that IgM-type HLA-specific Abs were detected mainly from the culture supernatants from PBMCs of patients with stable graft function, whereas IgG isotype HLA Abs were detectable only from patients with biopsy-proven antibody-mediated rejection. In other words, these IgG isotype Abs also represented an activated humoral immune response in vivo. Additionally, IgM- and IgG-expressing mBCs from healthy donors (n = 5 were cultured with IL-21, CpG-ODN, and a supernatant produced by stimulating CD19+ B-cell-depleted PBMCs with PHA-L and PMA in 24-well flat-bottom plates (1 × 105 cells/well, and the resulting in vitro analysis provided some

  12. Technical and clinical performance of a new assay to detect squamous cell carcinoma antigen levels for the differential diagnosis of cervical, lung, and head and neck cancer.

    Science.gov (United States)

    Holdenrieder, Stefan; Molina, Rafael; Qiu, Ling; Zhi, Xiuyi; Rutz, Sandra; Engel, Christine; Kasper-Sauer, Pia; Dayyani, Farshid; Korse, Catharina M

    2018-04-01

    In squamous cell carcinoma, squamous cell carcinoma antigen levels are often elevated. This multi-center study evaluated the technical performance of a new Elecsys ® squamous cell carcinoma assay, which measures serum squamous cell carcinoma antigen 1 and 2 levels in an equimolar manner, and investigated the potential of squamous cell carcinoma antigen for differential diagnosis of cervical, lung, and head and neck squamous cell carcinoma.Assay precision and method comparison experiments were performed across three European sites. Reference ranges for reportedly healthy individuals were determined using samples from banked European and Chinese populations. Differential diagnosis experiments determined whether cervical, lung, or head and neck cancer could be differentiated from apparently healthy, benign, or other malignant cohorts using squamous cell carcinoma antigen levels alone. Squamous cell carcinoma antigen cut-off levels were calculated based on squamous cell carcinoma antigen levels at 95% specificity. Repeatability coefficients of variation across nine analyte concentrations were ≤5.3%, and intermediate precision coefficients of variation were ≤10.3%. Method comparisons showed good correlations with Architect and Kryptor systems (slopes of 1.1 and 1.5, respectively). Reference ranges for 95th percentiles for apparently healthy individuals were 2.3 ng/mL (95% confidence interval: 1.9-3.8; European cohort, n = 153) and 2.7 ng/mL (95% confidence interval: 2.2-3.3; Chinese cohort, n = 146). Strongest differential diagnosis results were observed for cervical squamous cell carcinoma: receiver operating characteristic analysis showed that squamous cell carcinoma antigen levels (2.9 ng/mL cut-off) differentiate cervical squamous cell carcinoma (n = 127) from apparently healthy females (n = 286; area under the curve: 86.2%; 95% confidence interval: 81.8-90.6; sensitivity: 61.4%; specificity: 95.6%), benign diseases (n = 187; area

  13. Single-dilution enzyme-linked immunosorbent assay for quantification of antigen-specific salmonid antibody

    Science.gov (United States)

    Alcorn, S.W.; Pascho, R.J.

    2000-01-01

    An enzyme-linked immunosorbent assay (ELISA) was developed on the basis of testing a single dilution of serum to quantify the level of antibody to the p57 protein of Renibaclerium salmoninarum in sockeye salmon (Oncorhynchus nerka). The levels of antibody were interpolated from a standard curve constructed by relating the optical densities (OD) produced by several dilutions of a high-titer rainbow trout (O. mykiss) antiserum to the p57 protein. The ELISA OD values produced by as many as 36 test sera on each microplate were compared with the standard curve to calculate the antigen-specific antibody activity. Repeated measurements of 36 samples on 3 microplates on each of 6 assay dates indicated that the mean intraassay coefficient of variation (CV) was 6.68% (range, 0-23%) and the mean interassay CV was 8.29% (range, 4-16%). The antibody levels determined for the serum sample from 24 sockeye salmon vaccinated with a recombinant p57 protein generally were correlated with the levels determined by endpoint titration (r2 = 0.936) and with results from another ELISA that was based on extrapolation of antibody levels from a standard curve (r2 = 0.956). The single-dilution antibody ELISA described here increases the number of samples that can be tested on each microplate compared with immunoassays based on analysis of several dilutions of each test serum. It includes controls for interassay standardization and can be used to test fish weighing <3 g.

  14. Carcinoembryonic antigen: assay following heat compared with perchloric acid extraction in patients with colon cancer, non-neoplastic gastrointestinal diseases, or chronic renal failure

    International Nuclear Information System (INIS)

    Witherspoon, L.R.; Shuler, S.E.; Alyea, K.; Husserl, F.E.; Alton Ochsner Medical Foundation, New Orleans, LO)

    1983-01-01

    Heat inactivation has been proposed as an alternative to perchloric acid (PCA) precipitation for the extraction of carcinoembryonic antigen (CEA) from human plasma. A commercial RIA kit using heat inactivation was examined and results compared with those obtained with PCA precipitation. Adequate sensitivity (1.5 μg CEA/I plasma), satisfactory analytical recovery of CEA added to plasma, and dilutional linearity of samples found to have elevated CEA concentrations, were demonstrated for the heat-inactivation assay. Between-assay precision was better with the heat inactivation than with the PCA assay. Although the absolute concentration of CEA estimated after heat inactivation was consistently lower than that estimated after PCA extraction of plasma specimens, there was excellent correlation between results obtained with the two methods in colon cancer patients free of disease, colon cancer patients with residual or recurrent disease, patients with benign gastrointestinal disease, and in patients with chronic renal failure. The heat-inactivation assay is an excellent alternative to the PCA assay

  15. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    Energy Technology Data Exchange (ETDEWEB)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul [Seoul Metropolitan Government Seoul National University Boramae Medical Center, Seoul (Korea, Republic of); Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo [Seoul National University college of Medicine, Seoul (Korea, Republic of)

    2009-08-15

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2+-1.7%, 3.9+-2.1%, 7.1+-6.2%, 11.2+-7.2%. The CVs by random assay were 2.1+-1.7%, 4.8+-3.1%, 3.6+-4.8%, and 7.4+-6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  16. Comparison of Batch Assay and Random Assay Using Automatic Dispenser in Radioimmunoassay

    International Nuclear Information System (INIS)

    Moon, Seung Hwan; Jang, Su Jin; Kang, Ji Yeon; Lee, Dong Soo; Chung, June Key; Lee, Myung Chul; Lee, Ho Young; Shin, Sun Young; Min, Gyeong Sun; Lee, Hyun Joo

    2009-01-01

    Radioimmunoassay (RIA) was usually performed by the batch assay. To improve the efficiency of RIA without increase of the cost and time, random assay could be a choice. We investigated the possibility of the random assay using automatic dispenser by assessing the agreement between batch assay and random assay. The experiments were performed with four items; Triiodothyronine (T3), free thyroxine (fT4), Prostate specific antigen (PSA), Carcinoembryonic antigen (CEA). In each item, the sera of twenty patients, the standard, and the control samples were used. The measurements were done 4 times with 3 hour time intervals by random assay and batch assay. The coefficient of variation (CV) of the standard samples and patients' data in T3, fT4, PSA, and CEA were assessed. ICC (Intraclass correlation coefficient) and coefficient of correlation were measured to assessing the agreement between two methods. The CVs (%) of T3, fT4, PSA, and CEA measured by batch assay were 3.2±1.7%, 3.9±2.1%, 7.1±6.2%, 11.2±7.2%. The CVs by random assay were 2.1±1.7%, 4.8±3.1%, 3.6±4.8%, and 7.4±6.2%. The ICC between the batch assay and random assay were 0.9968 (T3), 0.9973 (fT4), 0.9996 (PSA), and 0.9901 (CEA). The coefficient of correlation between the batch assay and random assay were 0.9924(T3), 0.9974 (fT4), 0.9994 (PSA), and 0.9989 (CEA) (p<0.05). The results of random assay showed strong agreement with the batch assay in a day. These results suggest that random assay using automatic dispenser could be used in radioimmunoassay

  17. Assay of anti-HBs antibodies using a recombinant antigen and latex particle counting: comparison with five commercial tests.

    Science.gov (United States)

    Galanti, L M; Cornu, C; Masson, P L; Robert, A R; Becheanu, D; Lamy, M E; Cambiaso, C L

    1991-05-01

    An assay of anti-HBs antibodies based on agglutination of latex particles coated with recombinant HBs-antigen was compared with Abbott radioimmunoassay (Abbott-RIA), which uses a human plasma-derived antigen. The population examined consisted of 76 Abbott-RIA anti-HBs-negative prevaccinated subjects and 1044 serum samples anti-HBs found positive by Abbott-RIA, including 283 samples of subjects vaccinated either with a human plasma-derived vaccine (group A; n = 180) or with a recombinant vaccine (group B; n = 103). Correlation coefficients between the two techniques were respectively r = 0.89 for the whole population (n = 1044), r = 0.98 in group A and r = 0.74 in group B. Anti-HBs titres were higher with latex than with RIA in group B as shown by the regression slopes: latex = 508 + 1.11 RIA in group A and latex = -1138 + 3.97 RIA in group B, suggesting that some vaccinated subjects from group B produced antibodies against epitopes proper to the recombinant antigen. In the prevaccinated population and in group A, the latex results were compared with those of radioimmunoassays (Abbott, Sorin) and enzyme immunoassays (Behring, Roche, Pasteur). Only the Roche-EIA detected anti-HBs in the prevaccinated subjects. The correlation between the various immunoassays was r greater than 0.96 only for values higher than 100 IU/l.

  18. Monitoring T-Cell Responses in Translational Studies: Optimization of Dye-Based Proliferation Assay for Evaluation of Antigen-Specific Responses

    Directory of Open Access Journals (Sweden)

    Anja Ten Brinke

    2017-12-01

    Full Text Available Adoptive therapy with regulatory T cells or tolerance-inducing antigen (Ag-presenting cells is innovative and promising therapeutic approach to control undesired and harmful activation of the immune system, as observed in autoimmune diseases, solid organ and bone marrow transplantation. One of the critical issues to elucidate the mechanisms responsible for success or failure of these therapies and define the specificity of the therapy is the evaluation of the Ag-specific T-cell responses. Several efforts have been made to develop suitable and reproducible assays. Here, we focus on dye-based proliferation assays. We highlight with practical examples the fundamental issues to take into consideration for implementation of an effective and sensitive dye-based proliferation assay to monitor Ag-specific responses in patients. The most critical points were used to design a road map to set up and analyze the optimal assay to assess Ag-specific T-cell responses in patients undergoing different treatments. This is the first step to optimize monitoring of tolerance induction, allowing comparison of outcomes of different clinical studies. The road map can also be applied to other therapeutic interventions, not limited to tolerance induction therapies, in which Ag-specific T-cell responses are relevant such as vaccination approaches and cancer immunotherapy.

  19. Antigen-binding radioimmunoassays for human IgG antibodies to bovine ν-lactoglobulin

    International Nuclear Information System (INIS)

    Turner, M.W.; Paganelli, R.; Levinsky, R.J.; Williams, A.

    1983-01-01

    A double antibody antigen-binding assay for the detection of human IgG antibodies to the bovine milk allergen ν-lactoglobulin is described. The levels of such antibodies in patients with established cows' milk protein intolerance were significantly higher than the levels observed in a healthy control group (P<0.01). The assay showed excellent correlation with a solid phase antigen binding assay (rsub(s) = 0.8, P<0.001). (Auth.)

  20. A radioimmunoassay for human antibody specific for microbial antigens

    International Nuclear Information System (INIS)

    Tew, J.G.; Burmeister, J.; Greene, E.J.; Pflaumer, S.K.; Goldstein, J.

    1977-01-01

    A simple and sensitive method for detecting and quantitating antibody specific or microbial antigens is described. Bacterial, fungal, parasitic or viral antigens attached to bromoacetyl cellulose or the intact cells themselves were added to a series of two-fold dilutions of human serum. After a short incubation period, which allowed human antibody to attach to the antigens, the complex was thoroughly washed and carbon-14 labeled anti-human light chain antibody was added to each dilution. The resulting complex was washed, collected on a filter pad, placed in a scintillation vial and radioassayed. The relationship between radioactivity bound and -log 2 of the serum dilution was linear. The endpoint for each assay and a confidence interval was calculated by doing inverse prediction from simple linear regression. Results obtained using this assay indicated the presence of antibody in a pool of normal human sera specific for herpes virus and for both cell surface and intracellular antigens of Streptococcus mutans, Naegleria fowleri and Cryptococcus neoformans. In general the dominant response was against the intracellular antigens rather than cell surface antigens

  1. Whole blood microculture assay of human lymphocyte function.

    Science.gov (United States)

    Pauly, J L; Han, T

    1976-11-01

    A whole blood microculture assay is described for measuring lymphocyte reactivity to mitogenic and antigenic stimulants. This assay employs heparinized whole blood, serum-free culture medium, microtiter plates, and a Multiple Automated Sample Harvester (MASH). When this assay is compared to other leukocyte assays, its major advantages include (1) the utilization of fewer lymphocytes per microculture, thuus reducing the amount of blood required per test while increasing the number of test agents and replicate cultures which can be employed in any given experiment; (2) the conservation of mitogens, antigens, drugs, enzymes, hormones, lymphokines, and other test agents, some of which are either expensive of difficult to prepare in large quantities; (3) the elimination of lymphocyte isolation and purification procedures which may disrupt the relative proportion of T cells, B cells and antigen-processing cells; and (4) the application of an automated harvester which simplifies and expedites procedures required for processing cells for liquid scintillation counting.

  2. Immunoradiometric assay for cytomegalovirus-specific IgG antibodies

    International Nuclear Information System (INIS)

    Klapper, P.E.; Cleator, G.M.; Prinja-Wolks, D.; Morris, D.J.

    1990-01-01

    An immunoradiometric assay (radio-immunosorbent test; RIST) for the detection of IgG antibodies to human herpesvirus 4 [human cytomegalovirus (CMV)] has been developed. The technique utilizes CMV antigen passively adsorbed to a polyvinyl microtitration plate and a radiolabelled murine monoclonal anti-human IgG antibody to detect binding of human antibody to the 'solid phase' reagent. The assay was optimized, and its specifity confirmed by testing paired acute and convalescent sera from patients with acute CMV or other human herpesvirus infections. To determine the assay's sensitivity 1433 blood donor sera were examined. The RIST was more sensitive than a standard complement fixation (CFT). Use of a monoclonal anti-human IgG antibody in the RIST reduced non-specific binding to the control uninfected cell antigen such that blood donor sera could be tested in the assay using only a CMV antigen without generating an unacceptable false positive rate. (author). 23 refs.; 1 tab

  3. Serotype determination of Salmonella by xTAG assay.

    Science.gov (United States)

    Zheng, Zhibei; Zheng, Wei; Wang, Haoqiu; Pan, Jincao; Pu, Xiaoying

    2017-10-01

    Currently, no protocols or commercial kits are available to determine the serotypes of Salmonella by using Luminex MAGPIX®. In this study, an xTAG assay for serotype determination of Salmonella suitable for Luminex MAGPIX® is described and 228 Salmonella isolates were serotype determined by this xTAG assay. The xTAG assay consists of two steps: 1) Multiplex PCR to amplify simultaneously O, H and Vi antigen genes of Salmonella, and 2) Magplex-TAG™ microsphere hybridization to identify accurately the specific PCR products of different antigens. Compared with the serotyping results of traditional serum agglutination test, the sensitivity and specificity of the xTAG assay were 95.1% and 100%, respectively. The agreement rate of these two assays was 95.2%. Compared with Luminex xMAP® Salmonella Serotyping Assay (SSA) kit, the advantages of this xTAG assay are: First, the magnetic beads make it applicable to both the Luminex®100/200™ and MAGPIX® systems. Second, only primers rather than both primers and probes are needed in the xTAG assay, and the process of coupling antigen-specific oligonucleotide probes to beads is circumvented, which make the xTAG assay convenient to be utilized by other laboratories. The xTAG assay may serve as a rapid alternative or complementary method for traditional Salmonella serotyping tests, especially for laboratories that utilize the MAGPIX® systems. Copyright © 2017 Elsevier B.V. All rights reserved.

  4. Development of a Nucleoprotein-Based Enzyme-Linked Immunosorbent Assay Using a Synthetic Peptide Antigen for Detection of Avian Metapneumovirus Antibodies in Turkey Sera

    Science.gov (United States)

    Alvarez, Rene; Njenga, M. Kariuki; Scott, Melissa; Seal, Bruce S.

    2004-01-01

    Avian metapneumoviruses (aMPV) cause an upper respiratory tract disease with low mortality but high morbidity, primarily in commercial turkeys, that can be exacerbated by secondary infections. There are three types of aMPV, of which type C is found only in the United States. The aMPV nucleoprotein (N) amino acid sequences of serotypes A, B, and C were aligned for comparative analysis. On the basis of the predicted antigenicity of consensus sequences, five aMPV-specific N peptides were synthesized for development of a peptide antigen enzyme-linked immunosorbent assay (aMPV N peptide-based ELISA) to detect aMPV-specific antibodies among turkeys. Sera from naturally and experimentally infected turkeys were used to demonstrate the presence of antibodies reactive to the chemically synthesized aMPV N peptides. Subsequently, aMPV N peptide 1, which had the sequence 10-DLSYKHAILKESQYTIKRDV-29, with variations at only three amino acids among aMPV serotypes, was evaluated as a universal aMPV ELISA antigen. Data obtained with the peptide-based ELISA correlated positively with total aMPV viral antigen-based ELISAs, and the peptide ELISA provided higher optical density readings. The results indicated that aMPV N peptide 1 can be used as a universal ELISA antigen to detect antibodies for all aMPV serotypes. PMID:15013970

  5. Lea blood group antigen on human platelets

    International Nuclear Information System (INIS)

    Dunstan, R.A.; Simpson, M.B.; Rosse, W.F.

    1985-01-01

    One- and two-stage radioligand assays were used to determine if human platelets possess the Lea antigen. Goat IgG anti-Lea antibody was purified by multiple adsorptions with Le(a-b-) human red blood cells, followed by affinity chromatography with synthetic Lea substance and labeling with 125 I. Human IgG anti-Lea antibody was used either in a two stage radioassay with 125 I-labeled mouse monoclonal IgG anti-human IgG as the second antibody or, alternatively, purified by Staph protein A chromatography, labeled with 125 I, and used in a one-stage radioassay. Platelets from donors of appropriate red blood cell phenotypes were incubated with the antisera, centrifuged through phthalate esters, and assayed in a gamma scintillation counter. Dose response and saturation curve analysis demonstrate the presence of Lewis a antigen on platelets from Lea+ donors. Furthermore, platelets from an Le(a-b-) donor incubated in Le (a+b-) plasma adsorb Lea antigen in a similar manner to red blood cells. The clinical significance of these antigens in platelet transfusion remains undefined

  6. Chimeric rabbit/human Fab antibodies against the hepatitis Be-antigen and their potential applications in assays, characterization, and therapy.

    Science.gov (United States)

    Zhuang, Xiaolei; Watts, Norman R; Palmer, Ira W; Kaufman, Joshua D; Dearborn, Altaira D; Trenbeath, Joni L; Eren, Elif; Steven, Alasdair C; Rader, Christoph; Wingfield, Paul T

    2017-10-06

    Hepatitis B virus (HBV) infection afflicts millions worldwide, causing cirrhosis and liver cancer. HBV e-antigen (HBeAg), a clinical marker for disease severity, is a soluble variant of the viral capsid protein. HBeAg is not required for viral replication but is implicated in establishing immune tolerance and chronic infection. The structure of recombinant e-antigen (rHBeAg) was recently determined, yet to date, the exact nature and quantitation of HBeAg still remain uncertain. Here, to further characterize HBeAg, we used phage display to produce a panel of chimeric rabbit/human monoclonal antibody fragments (both Fab and scFv) against rHBeAg. Several of the Fab/scFv, expressed in Escherichia coli , had unprecedentedly high binding affinities ( K d ∼10 -12 m) and high specificity. We used Fab/scFv in the context of an enzyme-linked immunosorbent assay (ELISA) for HBeAg quantification, which we compared with commercially available kits and verified with seroconversion panels, the WHO HBeAg standard, rHBeAg, and patient plasma samples. We found that the specificity and sensitivity are superior to those of existing commercial assays. To identify potential fine differences between rHBeAg and HBeAg, we used these Fabs in microscale immunoaffinity chromatography to purify HBeAg from individual patient plasmas. Western blotting and MS results indicated that rHBeAg and HBeAg are essentially structurally identical, although HBeAg from different patients exhibits minor carboxyl-terminal heterogeneity. We discuss several potential applications for the humanized Fab/scFv.

  7. Molecular cloning of cDNA for the human tumor-associated antigen CO-029 and identification of related transmembrane antigens

    International Nuclear Information System (INIS)

    Szala, S.; Kasai, Yasushi; Steplewski, Z.; Rodeck, U.; Koprowski, H.; Linnenbach, A.J.

    1990-01-01

    The human tumor-associated antigen CO-029 is a monoclonal antibody-defined cell surface glycoprotein of 27-34 kDa. By using the high-efficiency COS cell expression system, a full-length cDNA clone for CO-029 was isolated. When transiently expressed in COS cells, the cDNA clone directed the synthesis of an antigen reactive to monoclonal antibody CO-029 in mixed hemadsorption and immunoblot assays. Sequence analysis revealed that CO-029 belongs to a family of cell surface antigens that includes the melanoma-associated antigen ME491, the leukocyte cell surface antigen CD37, and the Sm23 antigen of the parasitic helminth Schistosoma mansoni. CO-029 and ME491 antigen expression and the effect of their corresponding monoclonal antibodies on cell growth were compared in human tumor cell lines of various histologic origins

  8. Specificity of antigens on UV radiation-induced antigenic tumor cell variants measured in vitro and in vivo

    International Nuclear Information System (INIS)

    Hostetler, L.W.; Romerdahl, C.A.; Kripke, M.L.

    1989-01-01

    The purpose of this study was to determine whether antigenic variants cross-react immunologically with the parental tumor and whether the UVR-associated antigen unique to UVR-induced tumors is also present on the variants. Antigenic (regressor) variants and nonimmunogenic (progressor) clones derived from UV-irradiated cultures of the C3H K1735 melanoma and SF19 spontaneous fibrosarcoma cell lines were used to address these questions. In an in vivo immunization and challenge assay, the antigenic variants did not induce cross-protection among themselves, but each induced immunity against the immunizing variant, the parent tumor cells, and nonimmunogenic clones derived from UV-irradiated parent cultures. Therefore, the variants can be used to induce in mice a protective immunity that prevents the growth of the parent tumor and nonimmunogenic clones, but not other antigenic variants. In contrast, immunization with cells of the parental tumor or the nonimmunogenic clones induced no protective immunity against challenge with any of the cell lines. Utilizing the K1735 melanoma-derived cell lines in vitro, T-helper (Th) cells isolated from tumor-immunized mice were tested for cross-reactivity by their ability to collaborate with trinitrophenyl-primed B-cells in the presence of trinitrophenyl-conjugated tumor cells. Also, the cross-reactivity of cytotoxic T-lymphocytes from tumor-immunized mice was assessed by a 4-h 51Cr-release assay. Antigenic variants induced cytotoxic T-lymphocytes and Th activity that was higher than that induced by the parent tumor and nonimmunogenic clones from the UVR-exposed parent tumor and cross-reacted with the parental tumor cells and nonimmunogenic clones, but not with other antigenic variants

  9. An indirect antibody assay using haptenated antigen and 125I-labelled anti-hapten antibody

    International Nuclear Information System (INIS)

    Aalberse, R.C.; Amsterdam Univ.

    1978-01-01

    Hapten (trinitrophenyl) was coupled to antigen (ovalbumin). The haptenated antigen was bound by anti-ovalbumin antibody and binding was quantitated with 125 I-labelled anti-hapten antibodies. Thus, with a single radioactive reagent, antibodies against a variety of antigens can be detected while the problems inherent in a labelled antiglobulin binding test are avoided. In the ovalbumin system, the haptenated antigen binding test proved to be approximately 20 times as sensitive as the iodinated ovalbumin binding test

  10. Concepts and applications for influenza antigenic cartography

    Science.gov (United States)

    Cai, Zhipeng; Zhang, Tong; Wan, Xiu-Feng

    2011-01-01

    Influenza antigenic cartography projects influenza antigens into a two or three dimensional map based on immunological datasets, such as hemagglutination inhibition and microneutralization assays. A robust antigenic cartography can facilitate influenza vaccine strain selection since the antigenic map can simplify data interpretation through intuitive antigenic map. However, antigenic cartography construction is not trivial due to the challenging features embedded in the immunological data, such as data incompleteness, high noises, and low reactors. To overcome these challenges, we developed a computational method, temporal Matrix Completion-Multidimensional Scaling (MC-MDS), by adapting the low rank MC concept from the movie recommendation system in Netflix and the MDS method from geographic cartography construction. The application on H3N2 and 2009 pandemic H1N1 influenza A viruses demonstrates that temporal MC-MDS is effective and efficient in constructing influenza antigenic cartography. The web sever is available at http://sysbio.cvm.msstate.edu/AntigenMap. PMID:21761589

  11. A simplified radioimmunoassay for triiodothyronine (T3) using pre-incubated labelled antigen and antibody

    International Nuclear Information System (INIS)

    Pillai, M.R.A.; Nagvekar, U.H.; Desai, C.N.; Mani, R.S.

    1986-01-01

    The development of a simplified radioimmunoassay for triiodothyronine (T 3 ) using pre-incubated labelled T 3 and antibody is described. The assay is carried out by adding 50 μl of standard or sample to 0.4 ml of pre-incubated reagent dispensed in assay tubes. The reaction was allowed to proceed for about four hours and the antigen-antibody complex precipitated by the addition of 1 cm 3 of 22% polyethylene glycol solution. Due to the high dissociation constant of T 3 -antibody complex at 37 deg C, the labelled antigen-antibody complex dissociates and thereby the unlabelled antigen binds with the antibody. The sensitivity of this assay is comparable to an assay done by the equilibrium method using the same antibody. Sixty serum samples were analyzed using this method and were compared with the equilibrium assay. (author)

  12. Antigen-specific secretion of IFNγ and CXCL10 in whole blood assay detects Mycobacterium leprae infection but does not discriminate asymptomatic infection from symptomatic leprosy.

    Science.gov (United States)

    Hungria, Emerith Mayra; Freitas, Aline Araújo; Pontes, Maria Araci Andrade; Gonçalves, Heitor Sá; Sousa, Ana Lúcia Osório Maroccolo; Costa, Maurício Barcelos; Castilho, Mirian Lane Oliveira Rodrigues; Duthie, Malcolm S; Stefani, Mariane Martins Araújo

    2017-04-01

    To advance toward a whole blood assay (WBA)-based test capable of facilitating the diagnosis of paucibacillary (PB) leprosy, we evaluated a prototype in-tube WBA using combinations of Mycobacterium leprae antigens. Blood was collected from newly diagnosed untreated PB (n=38), multibacillary (MB) (n=30), healthy household contacts (HHC) of MB (n=27), and endemic controls (n=61) residing in Goiânia and Fortaleza, Brazil. Blood was incubated with M. leprae cell sonicate, recombinant proteins (46f+LID-1; ML0276+LID-1), or controls (phosphate-buffered saline, phytohemagglutinin, M. tuberculosis purified protein derivative). Antigen-specific IFNγ production was observed in 71-84% and 55% of PB and HHC, respectively. Antigen-specific CXCL10 levels were similarly assessed to determine if, unlike IFNγ, CXCL10 could differentiate PB from HHC with repeated exposure/asymptomatic M. leprae infection. The CXCL10 levels induced in response to M. leprae antigens could not, however, differentiate PB from HHC. Despite these limitations, the WBAs reported here still represent important tools for assessing M. leprae infection rates and evaluating the impact of control measures. Copyright © 2017 Elsevier Inc. All rights reserved.

  13. Antigenic evaluation of a recombinant baculovirus-expressed Sarcocystis neurona SAG1 antigen.

    Science.gov (United States)

    Gupta, G D; Lakritz, J; Saville, W J; Livingston, R S; Dubey, J P; Middleton, J R; Marsh, A E

    2004-10-01

    Sarcocystis neurona is the primary parasite associated with equine protozoal myeloencephalitis (EPM). This is a commonly diagnosed neurological disorder in the Americas that infects the central nervous system of horses. Current serologic assays utilize culture-derived parasites as antigen. This method requires large numbers of parasites to be grown in culture, which is labor intensive and time consuming. Also, a culture-derived whole-parasite preparation contains conserved antigens that could cross-react with antibodies against other Sarcocystis species and members of Sarcocystidae such as Neospora spp., Hammondia spp., and Toxoplasma gondii. Therefore, there is a need to develop an improved method for the detection of S. neurona-specific antibodies. The sera of infected horses react strongly to surface antigen 1 (SnSAG1), an approximately 29-kDa protein, in immunoblot analysis, suggesting that it is an immunodominant antigen. The SnSAG1 gene of S. neurona was cloned, and recombinant S. neurona SAG1 protein (rSnSAG1-Bac) was expressed with the use of a baculovirus system. By immunoblot analysis, the rSnSAG1-Bac antigen detected antibodies to S. neurona from naturally infected and experimentally inoculated equids, cats, rabbit, mice, and skunk. This is the first report of a baculovirus-expressed recombinant S. neurona antigen being used to detect anti-S. neurona antibodies in a variety of host species.

  14. Clinical utility of the cryptococcal antigen lateral flow assay in a diagnostic mycology laboratory.

    Directory of Open Access Journals (Sweden)

    Brendan J McMullan

    Full Text Available BACKGROUND: Cryptococcus neoformans causes life-threatening meningitis. A recently introduced lateral flow immunoassay (LFA to detect cryptococcal antigen (CRAG is reportedly more rapid and convenient than standard latex agglutination (LA, but has not yet been evaluated in a diagnostic laboratory setting. METHODS: One hundred and six serum, 42 cerebrospinal fluid (CSF, and 20 urine samples from 92 patients with known or suspected cryptococcosis were tested by LA and LFA, and titres were compared. Results were correlated with laboratory-confirmed cryptococcosis. Serial samples were tested in nine treated patients. RESULTS: Twenty-five of 92 patients had confirmed cryptococcosis; all sera (n = 56 from these patients were positive by LFA (sensitivity 100%, 95% confidence interval (CI 93.6-100% compared with 51/56 positive by LA (sensitivity 91.1%, 95% CI 80.7-96.1%. Fifty sera from 67 patients without cryptococcosis tested negative in both assays. While LA yielded more false negative results (5/56 this did not reach statistical significance (p = 0.063. Nine CSF samples from patients with cryptococcal meningitis yielded positive results using both assays while 17/18 urine samples from patients with cryptococcosis were positive by the LFA. The LFA detected CRAG in C. gattii infection (n = 4 patients. Agreement between titres obtained by both methods (n = 38 samples was imperfect; correlation between log-transformed titres (r was 0.84. Turn-around-time was 20 minutes for the LFA and 2 h for LA. The cost per qualitative sample was 18USD and 91 USD, respectively and per quantitative sample was 38USD and 144USD, respectively. CONCLUSIONS: Qualitative agreement between the LFA and LA assays performed on serum and CSF was good but agreement between titres was imperfect. Ease of performance of the LFA and the capacity for testing urine suggest it has a role in the routine laboratory as a rapid diagnostic test or point-of-care test.

  15. Comparison of antigen-specific T-cell responses of tuberculosis patients using complex or single antigens of Mycobacterium tuberculosis

    DEFF Research Database (Denmark)

    Mustafa, A S; Amoudy, H A; Wiker, H G

    1998-01-01

    We have screened peripheral blood mononuclear cells (PBMC) from tuberculosis (TB) patients for proliferative reactivity and interferon-gamma (IFN-gamma) secretion against a panel of purified recombinant (r) and natural (n) culture filtrate (rESAT-6, nMPT59, nMPT64 and nMPB70) and somatic-derived (r......GroES, rPstS, rGroEL and rDnaK) antigens of Mycobacterium tuberculosis. The responses of PBMC to these defined antigens were compared with the corresponding results obtained with complex antigens, such as whole-cell M. tuberculosis, M. tuberculosis culture filtrate (MT-CF) and cell wall antigens, as well...... as the vaccine strain, Mycobacterium bovis bacillus Calmette-Guerin (BCG). In addition, M. tuberculosis and MT-CF-induced T-cell lines were tested in the same assays against the panel of purified and complex antigens. The compiled data from PBMC and T-cell lines tested for antigen-induced proliferation and IFN...

  16. Evaluation of a newly designed sandwich enzyme linked immunosorbent assay for the detection of hydatid antigen in serum, urine and cyst fluid for diagnosis of cystic echinococcosis.

    Science.gov (United States)

    Chaya, Dr; Parija, Subhash Chandra

    2013-07-01

    Cystic echinococcosis (CE) is a zoonotic disease of humans with variable clinical manifestations. Imaging and immunological methods are currently the mainstay of diagnosis of this disease. Although the immunological tests for detection of anti-echinococcal antibodies have several disadvantages, they are widely being used. Antigen is far more superior than antibody detection test as they can provide a specific parasitic diagnosis. A sandwich enzyme linked immunosorbent assay (ELISA) was designed using antibodies to 24 kDa urinary hydatid antigen for the detection of hydatid antigens in urine, serum and cyst fluid specimens. The performance of this novel test was compared with that of other hydatid antibody detection ELISA and enzyme immune transfer blot (EITB) using radiological and surgical confirmation as the gold standard. The antigen detection ELISA showed 100% sensitivity and specificity when tested with cyst fluid. On testing urine and serum, the antigen detection ELISA was found to be more specific than antibody detection ELISA. EITB was found to be the most sensitive and specific test. ELISA using polyclonal antibodies against 24 kDa urinary hydatid protein was moderately sensitive to detect hydatid antigen in serum and urine. Hence polyclonal antibodies to 24 kDa urinary hydatid antigen can be used as an alternative source of antibody to detect hydatid antigen in serum, urine and cyst fluid. In the present study, EITB was found to be highly specific test for detection of hydatid antibodiesin serum. 24 kDa protein was found to be specific and of diagnostic value in CE.

  17. Performance of hepatitis B assays on the Bayer ADVIA Centaur Immunoassay System.

    Science.gov (United States)

    van Helden, Josef; Denoyel, Gérard; Karwowska, Sylwia; Reamer, Randy; Schmalz, John; Wright, Ted; Preisel-Simmons, Barbara

    2004-01-01

    Bayer HealthCare LLC, Diagnostics Division, has developed several new assays on the ADVIA Centaur immunoassay system for the detection of markers of hepatitis B virus infection in human serum and plasma. This panel includes assays for: hepatitis B surface antigen (HBsAg), a confirmatory test method for HBsAg, antibodies to hepatitis B surface antigen (anti-HBs), IgM and IgG antibodies to hepatitis B core antigen (anti-HBc Total) and IgM antibodies to hepatitis B core antigen (anti-HBc IgM). These assays employ magnetic particle separation technology with direct chemiluminescence for optimal assay performance. All of the assays are fully automated, require sample volumes ranging from 15 microl to 100 microl (with the exception of the ADVIA Centaur HBsAg Confirmatory Assay, which requires 2 x 100 microl), and have throughputs of up to 240 tests per hour. The five ADVIA Centaur HBV assays were tested in extensive performance evaluations conducted at two sites in Europe. The performance evaluations, which included samples from HBV-infected individuals, blood donors, hospitalized/clinical patients, and HBV vaccinees (for Anti-HBs evaluation), generated performance data in support of obtaining the Communautés Européennes (CE) mark for European market distribution. The HBV performance evaluations resulted in an overall diagnostic specificity > 99%, i.e. 99.94% for the ADVIA Centaur HBsAg Assay, 100% for the ADVIA Centaur Anti-HBs Assay, 100% for the ADVIA Centaur HBc IgM Assay and 99.94% for the ADVIA Centaur HBc Total Assay. All of the ADVIA Centaur assays showed a very good diagnostic sensitivity on these populations with 100% for the ADVIA Centaur HBsAg Assay, 99.0% for the ADVIA Centaur Anti-HBs Assay, 98.53% for the ADVIA Centaur HBc IgM Assay and 100% for the ADVIA Centaur HBc Total Assay. The ADVIA Centaur HBsAg Confirmatory Test confirmed 100% of the positive HBsAg samples. Testing of interfering substances and potential cross-reacting samples for all ADVIA

  18. Differentiation of foot-and-mouth disease virus-infected from vaccinated pigs by enzyme-linked immunosorbent assay using nonstructural protein 3AB as the antigen and application to an eradication program

    DEFF Research Database (Denmark)

    Chung, Wen Bin; Sørensen, Karl Johan; Liao, Pei Chih

    2002-01-01

    Baculovirus-expressed foot-and-mouth disease virus (FMDV) nonstructural protein 3AB was used as the antigen in an enzyme-linked immunosorbent assay. This assay allowed the differentiation of vaccinated from infected pigs. Serial studies were performed using sera collected from pigs in the field...... in Taiwan showed that the positive reactors steadily decreased over time in both finishers and sows, indicating that the pig population risk of infection by FMDV has decreased....

  19. Ultrasensitive prostate specific antigen assay following laparoscopic radical prostatectomy--an outcome measure for defining the learning curve.

    Science.gov (United States)

    Viney, R; Gommersall, L; Zeif, J; Hayne, D; Shah, Z H; Doherty, A

    2009-07-01

    Radical retropubic prostatectomy (RRP) performed laparoscopically is a popular treatment with curative intent for organ-confined prostate cancer. After surgery, prostate specific antigen (PSA) levels drop to low levels which can be measured with ultrasensitive assays. This has been described in the literature for open RRP but not for laparoscopic RRP. This paper describes PSA changes in the first 300 consecutive patients undergoing non-robotic laparoscopic RRP by a single surgeon. To use ultrasensitive PSA (uPSA) assays to measure a PSA nadir in patients having laparoscopic radical prostatectomy below levels recorded by standard assays. The aim was to use uPSA nadir at 3 months' post-prostatectomy as an early surrogate end-point of oncological outcome. In so doing, laparoscopic oncological outcomes could then be compared with published results from other open radical prostatectomy series with similar end-points. Furthermore, this end-point could be used in the assessment of the surgeon's learning curve. Prospective, comprehensive, demographic, clinical, biochemical and operative data were collected from all patients undergoing non-robotic laparoscopic RRP. We present data from the first 300 consecutive patients undergoing laparoscopic RRP by a single surgeon. uPSA was measured every 3 months post surgery. Median follow-up was 29 months (minimum 3 months). The likelihood of reaching a uPSA of bench-marking performance. With experience, a surgeon can achieve in excess of an 80% chance of obtaining a uPSA nadir of < or = 0.01 ng/ml at 3 months after laparoscopic RRP for a British population. This is equivalent to most published open series.

  20. Inclusion bodies of recombinant Epstein-Barr virus capsid antigen p18 as potential immobilized antigens in enzyme immunoassays for detection of nasopharyngeal carcinoma.

    Science.gov (United States)

    Lim, Chun Shen; Goh, Siang Ling; Kariapper, Leena; Krishnan, Gopala; Lim, Yat-Yuen; Ng, Ching Ching

    2015-08-25

    Development of indirect enzyme-linked immunosorbent assays (ELISAs) often utilizes synthetic peptides or recombinant proteins from Escherichia coli as immobilized antigens. Because inclusion bodies (IBs) formed during recombinant protein expression in E. coli are commonly thought as misfolded aggregates, only refolded proteins from IBs are used to develop new or in-house diagnostic assays. However, the promising utilities of IBs as nanomaterials and immobilized enzymes as shown in recent studies have led us to explore the potential use of IBs of recombinant Epstein-Barr virus viral capsid antigen p18 (VCA p18) as immobilized antigens in ELISAs for serologic detection of nasopharyngeal carcinoma (NPC). Thioredoxin fusion VCA p18 (VCA-Trx) and IBs of VCA p18 without fusion tags (VCA-IBs) were purified from E. coli. The diagnostic performances of IgG/VCA-IBs, IgG/VCA-Denat-IBs (using VCA-IBs coated in 8mol/l urea), IgG/VCA-Trx, and IgG/VCA-Peptide assays were compared by screening 100 NPC case-control pairs. The IgG/VCA-Denat-IBs assay showed the best area under the receiver operating characteristic curve (AUC: 0.802; p<0.05), while the AUCs for the IgG/VCA-IBs, IgG/VCA-Trx, and IgG/VCA-Peptide assays were comparable (AUC: 0.740, 0.727, and 0.741, respectively). We improved the diagnostic performance of the ELISA significantly using IBs of recombinant VCA p18. Copyright © 2015 Elsevier B.V. All rights reserved.

  1. ELISA with double antigen sandwich for screening specific serum anti-TP antibody in blood donors

    International Nuclear Information System (INIS)

    Wang Yiqing; Shi Zhixu

    2002-01-01

    Objective: To select a sensitive and specific laboratory examination suitable for screening serum anti-TP antibody in blood donors. Methods: The serum anti-TP antibody in 11271 blood donors were detected using ELISA with double antigen sandwich and the outcomes were compared with those using RPR assay. The conflicting specimen were confirmed by repeating the test with TPHA assay. Results: The positive rates of serum anti-TP antibody by ELISA with double antigen sandwich and RPR was 0.36% (41/11271) and 0.26% (29/11271), respectively. The coincidence of the detecting outcomes by ELISA with double antigen sandwich and RPR with TPHA was 97.5% (40/41) and 63.41%(26/41) respectively. Conclusion: Compared with RPR assay, ELISA with double antigen sandwich has higher sensibility and specificity for screening serum anti-TP antibody in blood donors

  2. A radioimmunoassay to screen for antibodies to native conformational antigens and analyse ligand-induced structural states of antigenic proteins

    International Nuclear Information System (INIS)

    Bernotat-Danielowski, S.; Koepsell, H.

    1988-01-01

    A radioimmunoassay is described in which antigenic protein was immobilized by incubating nitrocellulose filters of defined diameter with antigen-containing solutions. Antigenic sites which are sensitive to protein denaturation by drying could be detected with the assay. The assay was also used to screen hybridoma supernatants for antibodies directed against Na + cotransport proteins from renal brush-border membranes. Monoclonal antibodies were selected which showed different binding charactertics depending on whether or not substrates of Na + cotransporters were present. One of the antibodies, which showed different antibody binding after addition of D-glucose or L-lactate, bound to a polypeptide component of the renal N + -D-glucose cotransporter and was able to inhibit Na + gradient-dependent. To investigate the effects of D-glucose and L-lactate on the binding of this antibody concentration dependence was measured. High and low affinity binding sites for D-glucose and L-lactate were characterized thereby demonstrating that the radioimmunoassay permits investigations of the properties of high and low affinity substrate binding sites. (author). refs.; 6 figs.; 2 tabs

  3. A versatile, high through-put, bead-based phagocytosis assay for Plasmodium falciparum

    DEFF Research Database (Denmark)

    Lloyd, Yukie M.; Ngati, Elise P.; Salanti, Ali

    2017-01-01

    Antibody-mediated phagocytosis is an important immune effector mechanism against Plasmodium falciparum-infected erythrocytes (IE); however, current phagocytosis assays use IE collected from infected individuals or from in vitro cultures of P. falciparum, making them prone to high variation....... A simple, high-throughput flow cytometric assay was developed that uses THP-1 cells and fluorescent beads covalently-coupled with the malarial antigen VAR2CSA. The assay is highly repeatable, provides both the overall percent phagocytosis and semi-quantitates the number of antigen-coupled beads...

  4. Time-resolved immunofluorometric assay of serum ferritin

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Yao [China Inst. of Atomic Energy, Beijing (China)

    2007-06-15

    This assay is a solid phase, two-site fluoroimmunometric assay based on the direct sandwish technique. Standards or samples containing ferritin are first reacted with immobilized anti-ferritin antibodies. Then the europium-lablled antibodies are reacted with the bound antigen. The range of this assay is 2-1000 ng/mL. The analytical sentivity is better than 0.05 ng/mL. The intra-assay variation and inter-assay variation are both below 5%; This kit was compared with Wallac DELFIA kit. The correlation is r=0.96. (authors)

  5. Evaluation of an Antigen-Antibody “Combination” Enzyme Linked ...

    African Journals Online (AJOL)

    Conclusion: We conclude that although this assay depicts high sensitivity and specificity in detecting antibodies to HCV, it seems not to add further benefit in our study population to detect HCV infections by enhanced sensitivity due the potential contingency to trace viral capsid antigens. Keywords: Ag-Ab Combination assay ...

  6. Performance of ARCHITECT HCV core antigen test with specimens from US plasma donors and injecting drug users.

    Science.gov (United States)

    Mixson-Hayden, Tonya; Dawson, George J; Teshale, Eyasu; Le, Thao; Cheng, Kevin; Drobeniuc, Jan; Ward, John; Kamili, Saleem

    2015-05-01

    Hepatitis C virus (HCV) core antigen is a serological marker of current HCV infection. The aim of this study was mainly to evaluate the performance characteristics of the ARCHITECT HCV core antigen assay with specimens from US plasma donors and injecting drug users. A total of 551 serum and plasma samples with known anti-HCV and HCV RNA status were tested for HCV core antigen using the Abbott ARCHITECT HCV core antigen test. HCV core antigen was detectable in 100% of US plasma donor samples collected during the pre-seroconversion phase of infection (anti-HCV negative/HCV RNA positive). Overall sensitivity of the HCV core antigen assay was 88.9-94.3% in samples collected after seroconversion. The correlation between HCV core antigen and HCV RNA titers was 0.959. HCV core antigen testing may be reliably used to identify current HCV infection. Published by Elsevier B.V.

  7. Establishment of an in vivo potency assay for the recombinant hepatit is B surface antigen in monovalent and combined vaccines

    Directory of Open Access Journals (Sweden)

    Mabel Izquierdo-López

    2014-12-01

    Full Text Available In this paper the development of potency assay in animals (mice was made, with the objective of demonstrating the immunogenic power of the recombinant Hepatitis B surface antigen in monovalent and combined vaccines, produced at the Center of Genetic Engineering and Biotechnology. The potency test is a parameter in quality control and it is also a tool to demonstrate the consistency of the production process. Parameters such as duration of the test, number of animals in the test, as well as different areas for the maintenance of the animals were evaluated. The results on the applicability of the potency test, to two presentations of the vaccines; monovalent Heberbiovac HB and pentavalent liquid in one vial Heberpenta-L are shown, for which specificity studies, evaluating different vaccine lots, the behavior of linearity, and parallelism, as well as establishing quality specification of the test were performed. This assay led to the obtainment of reliable results for the vaccines evaluated, the consistent evaluation of the immunogenic power and the monitoring of different production processes.

  8. Large Scale Immune Profiling of Infected Humans and Goats Reveals Differential Recognition of Brucella melitensis Antigens

    Science.gov (United States)

    Liang, Li; Leng, Diana; Burk, Chad; Nakajima-Sasaki, Rie; Kayala, Matthew A.; Atluri, Vidya L.; Pablo, Jozelyn; Unal, Berkay; Ficht, Thomas A.; Gotuzzo, Eduardo; Saito, Mayuko; Morrow, W. John W.; Liang, Xiaowu; Baldi, Pierre; Gilman, Robert H.; Vinetz, Joseph M.; Tsolis, Renée M.; Felgner, Philip L.

    2010-01-01

    Brucellosis is a widespread zoonotic disease that is also a potential agent of bioterrorism. Current serological assays to diagnose human brucellosis in clinical settings are based on detection of agglutinating anti-LPS antibodies. To better understand the universe of antibody responses that develop after B. melitensis infection, a protein microarray was fabricated containing 1,406 predicted B. melitensis proteins. The array was probed with sera from experimentally infected goats and naturally infected humans from an endemic region in Peru. The assay identified 18 antigens differentially recognized by infected and non-infected goats, and 13 serodiagnostic antigens that differentiate human patients proven to have acute brucellosis from syndromically similar patients. There were 31 cross-reactive antigens in healthy goats and 20 cross-reactive antigens in healthy humans. Only two of the serodiagnostic antigens and eight of the cross-reactive antigens overlap between humans and goats. Based on these results, a nitrocellulose line blot containing the human serodiagnostic antigens was fabricated and applied in a simple assay that validated the accuracy of the protein microarray results in the diagnosis of humans. These data demonstrate that an experimentally infected natural reservoir host produces a fundamentally different immune response than a naturally infected accidental human host. PMID:20454614

  9. Correlation between the e-antigen, Pre-S2 antigen and DNA of hepatitis B virus

    International Nuclear Information System (INIS)

    Cai Changhui; Liang Jinsheng

    2006-01-01

    Objective: To study the relationship between the hepatitis B e-antigen (HBeAg), Pre-S1 antigen (Pre-S1), Pre-S2 antigen (Pre-S2) and DNA of hepatitis B virus (HBV). Methods: The blood samples of 268 cases of viral B hepatitis were collected. The HBV DNA of all samples were tested by fluorescent-quantitating PCR method, and HBeAg were assayed by time-resolved fluoro-immunoassay method, and their Pre-S1 and Pre-S2 were assayed by enzyme linked immunosorbentassay method. Results: The positive rates of HBeAg, Pre-S1 and Pre-S2 in HBV DNA positive group were 48.2%, 76.4% and 100% respectively, and 1.6%, 36.3% and 32.3% respectively in HBV DNA negative group. There was significantly difference between the HBeAg, Pre-S1 and Pre-S2 positive rates of the two groups (Chi-square test, P<0.01). Conclusions: There was positive relationship between the HBeAg, Pre-S1, Pre-S2 and DNA which all were indicators of HBV reproduction. Comparing to HBV DNA, Pre-S2 was the most, Pre-S1 the second, and HBeAg the third sensitive indicator for evaluating HBV reproduction. Pre-S1 and Pre-S2 could be used as the supplementary indicator for the reproduction of HBV. (authors)

  10. Real-time PCR analysis of genes encoding tumor antigens in esophageal tumors and a cancer vaccine

    DEFF Research Database (Denmark)

    Weinert, Brian T; Krishnadath, Kausilia K; Milano, Francesca

    2009-01-01

    Tumor antigens are the primary target of therapeutic cancer vaccines. We set out to define and compare the expression pattern of tumor antigen genes in esophagus carcinoma biopsies and in an allogeneic tumor lysate-based cancer vaccine, MelCancerVac. Cells used for vaccine production were treated...... in the production of the vaccine. Quantitative PCR was used to assay 74 tumor antigen genes in patients with squamous cell carcinoma of the esophagus. 81% (13/16) of tumors expressed more than five cancer/testis (CT) antigens. A total of 96 genes were assayed in the tumor cell clone (DDM1.7) used to make tumor cell...

  11. Low cut-off values increase diagnostic performance of protein S assays

    NARCIS (Netherlands)

    Mulder, Rene; ten Kate, Min Ki; Kluin-Nelemans, Hanneke C.; Mulder, Andre B.

    Conflicting data have been reported on the accuracy of protein S (PS) assays for detection of hereditary PS deficiency. In this study we assessed the diagnostic performance of two total PS antigen assays, four free PS assays and three PS activity assays in a group of 28 heterozygous carriers of

  12. LATERAL FLOW ASSAY FOR CRYPTOCOCCAL ANTIGEN: AN IMPORTANT ADVANCE TO IMPROVE THE CONTINUUM OF HIV CARE AND REDUCE CRYPTOCOCCAL MENINGITIS-RELATED MORTALITY

    Directory of Open Access Journals (Sweden)

    Jose E. VIDAL

    2015-09-01

    Full Text Available SUMMARYAIDS-related cryptococcal meningitis continues to cause a substantial burden of death in low and middle income countries. The diagnostic use for detection of cryptococcal capsular polysaccharide antigen (CrAg in serum and cerebrospinal fluid by latex agglutination test (CrAg-latex or enzyme-linked immunoassay (EIA has been available for over decades. Better diagnostics in asymptomatic and symptomatic phases of cryptococcosis are key components to reduce mortality. Recently, the cryptococcal antigen lateral flow assay (CrAg LFA was included in the armamentarium for diagnosis. Unlike the other tests, the CrAg LFA is a dipstick immunochromatographic assay, in a format similar to the home pregnancy test, and requires little or no lab infrastructure. This test meets all of the World Health Organization ASSURED criteria (Affordable, Sensitive, Specific, User friendly, Rapid/robust, Equipment-free, and Delivered. CrAg LFA in serum, plasma, whole blood, or cerebrospinal fluid is useful for the diagnosis of disease caused by Cryptococcusspecies. The CrAg LFA has better analytical sensitivity for C. gattii than CrAg-latex or EIA. Prevention of cryptococcal disease is new application of CrAg LFA via screening of blood for subclinical infection in asymptomatic HIV-infected persons with CD4 counts < 100 cells/mL who are not receiving effective antiretroviral therapy. CrAg screening of leftover plasma specimens after CD4 testing can identify persons with asymptomatic infection who urgently require pre-emptive fluconazole, who will otherwise progress to symptomatic infection and/or die.

  13. Radioimmunoassay for hepatitis B core antigen

    International Nuclear Information System (INIS)

    Sagnelli, E.; Pereira, C.; Triolo, G.; Vernace, S.; Paronetto, F.

    1982-01-01

    Serum hepatitis B core antigen (HBcAg) is an important marker of hepatitis B virus replication. We describe an easy, sensitive radioimmunoassay for determination of HBcAg in detergent-treated serum pellets containing Dane particles. Components of a commercial kit for anticore determination are used, and HBcAG is measured by competitive inhibition of binding of 125 I-labeled antibodies to HBcAg with HBcAg-coated beads. We assayed for HBcAG in the sera of 49 patients with hepatitis B surface antigen (HBsAg)-positive chronic hepatitis, 50 patients with HBsAg-negative chronic hepatitis, and 30 healthy volunteers. HBcAg was detected in 41% of patients with HBsAg-positive chronic hepatitis but not in patients with HBsAg-negative chronic hepatitis. Hepatitis Be antigen (an antigen closely associated with the core of Dane particles) determined in the same sera by radioimmunoassay, was not detected in 50% of HBcAg-positive sera

  14. Toward low-cost affinity reagents: lyophilized yeast-scFv probes specific for pathogen antigens.

    Directory of Open Access Journals (Sweden)

    Sean A Gray

    Full Text Available The generation of affinity reagents, usually monoclonal antibodies, remains a critical bottleneck in biomedical research and diagnostic test development. Recombinant antibody-like proteins such as scFv have yet to replace traditional monoclonal antibodies in antigen detection applications, in large part because of poor performance of scFv in solution. To address this limitation, we have developed assays that use whole yeast cells expressing scFv on their surfaces (yeast-scFv in place of soluble purified scFv or traditional monoclonal antibodies. In this study, a nonimmune library of human scFv displayed on the surfaces of yeast cells was screened for clones that bind to recombinant cyst proteins of Entamoeba histolytica, an enteric pathogen of humans. Selected yeast-scFv clones were stabilized by lyophilization and used in detection assay formats in which the yeast-scFv served as solid support-bound monoclonal antibodies. Specific binding of antigen to the yeast-scFv was detected by staining with rabbit polyclonal antibodies. In flow cytometry-based assays, lyophilized yeast-scFv reagents retained full binding activity and specificity for their cognate antigens after 4 weeks of storage at room temperature in the absence of desiccants or stabilizers. Because flow cytometry is not available to all potential assay users, an immunofluorescence assay was also developed that detects antigen with similar sensitivity and specificity. Antigen-specific whole-cell yeast-scFv reagents can be selected from nonimmune libraries in 2-3 weeks, produced in vast quantities, and packaged in lyophilized form for extended shelf life. Lyophilized yeast-scFv show promise as low cost, renewable alternatives to monoclonal antibodies for diagnosis and research.

  15. Radiation and chemical effects on viral transformation and tumor antigen expression. Annual progress report, August 1, 1978--May 1, 1979

    International Nuclear Information System (INIS)

    Coggin, J.H. Jr.

    1979-01-01

    Studies aimed at the biological, biochemical, and immunologic characterization of fetal antigens (EA) in hamsters and mice and locating and determining the distribution of fetal antigens in tumor tissues and in developing fetuses have been underway for several months. Progress has been made in isolating embryonic or fetal antigens from fetuses and from tumor cells. We have developed and reported a reliable lymphocyte transformation assay (LTA) which meets our needs in routinely assaying cell free tumor associated antigen (TAA) preparations from fetal and tumor cells. The assay correlated with transplantation resistance assays and has appropriate specificity. We have also developed the staph-A protein binding assay utilizing anti-serum derived against embryonic antigens present on SV40 tumor cells. In other studies, we have reported increases and perturbations in thymocytes during viral and chemical oncogenesis in hamsters, have developed a simple technique for preserving functional lymphocytes sensitized against TAA by freezing for use in our model system work, have reported the cross-reactivity of tranplantation resistance antigen on a spectrum of chemically induced tumors previously believed to only contain individually specific TSTAs and have recently reported the cross-reactivity of papovavirus induced transplantation resistance antigen in sarcoma cells induced by different viruses. We have concluded our studies of glycosyltransferases in the membranes of developing fetuses and noted no differences in their levels with advancing days of gestation using whold embryo cell populations

  16. Specific Antibodies Reacting with SV40 Large T Antigen Mimotopes in Serum Samples of Healthy Subjects.

    Directory of Open Access Journals (Sweden)

    Mauro Tognon

    Full Text Available Simian Virus 40, experimentally assayed in vitro in different animal and human cells and in vivo in rodents, was classified as a small DNA tumor virus. In previous studies, many groups identified Simian Virus 40 sequences in healthy individuals and cancer patients using PCR techniques, whereas others failed to detect the viral sequences in human specimens. These conflicting results prompted us to develop a novel indirect ELISA with synthetic peptides, mimicking Simian Virus 40 capsid viral protein antigens, named mimotopes. This immunologic assay allowed us to investigate the presence of serum antibodies against Simian Virus 40 and to verify whether Simian Virus 40 is circulating in humans. In this investigation two mimotopes from Simian Virus 40 large T antigen, the viral replication protein and oncoprotein, were employed to analyze for specific reactions to human sera antibodies. This indirect ELISA with synthetic peptides from Simian Virus 40 large T antigen was used to assay a new collection of serum samples from healthy subjects. This novel assay revealed that serum antibodies against Simian Virus 40 large T antigen mimotopes are detectable, at low titer, in healthy subjects aged from 18-65 years old. The overall prevalence of reactivity with the two Simian Virus 40 large T antigen peptides was 20%. This new ELISA with two mimotopes of the early viral regions is able to detect in a specific manner Simian Virus 40 large T antigen-antibody responses.

  17. 21 CFR 866.3310 - Hepatitis A virus (HAV) serological assays.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Hepatitis A virus (HAV) serological assays. 866... Hepatitis A virus (HAV) serological assays. (a) Identification. HAV serological assays are devices that consist of antigens and antisera for the detection of hepatitis A virus-specific IgM, IgG, or total...

  18. Metal-amplified Density Assays, (MADAs), including a Density-Linked Immunosorbent Assay (DeLISA).

    Science.gov (United States)

    Subramaniam, Anand Bala; Gonidec, Mathieu; Shapiro, Nathan D; Kresse, Kayleigh M; Whitesides, George M

    2015-02-21

    This paper reports the development of Metal-amplified Density Assays, or MADAs - a method of conducting quantitative or multiplexed assays, including immunoassays, by using Magnetic Levitation (MagLev) to measure metal-amplified changes in the density of beads labeled with biomolecules. The binding of target analytes (i.e. proteins, antibodies, antigens) to complementary ligands immobilized on the surface of the beads, followed by a chemical amplification of the binding in a form that results in a change in the density of the beads (achieved by using gold nanoparticle-labeled biomolecules, and electroless deposition of gold or silver), translates analyte binding events into changes in density measureable using MagLev. A minimal model based on diffusion-limited growth of hemispherical nuclei on a surface reproduces the dynamics of the assay. A MADA - when performed with antigens and antibodies - is called a Density-Linked Immunosorbent Assay, or DeLISA. Two immunoassays provided a proof of principle: a competitive quantification of the concentration of neomycin in whole milk, and a multiplexed detection of antibodies against Hepatitis C virus NS3 protein and syphilis T. pallidum p47 protein in serum. MADAs, including DeLISAs, require, besides the requisite biomolecules and amplification reagents, minimal specialized equipment (two permanent magnets, a ruler or a capillary with calibrated length markings) and no electrical power to obtain a quantitative readout of analyte concentration. With further development, the method may be useful in resource-limited or point-of-care settings.

  19. Identification of toxocara canis antigens by Western blot in experimentally infected rabbits

    Directory of Open Access Journals (Sweden)

    MORALES Olga Lucía

    2002-01-01

    Full Text Available Toxocariasis is a frequent helminthiasis that can cause visceral and ocular damage in humans specially in children. The identification of specific antigens of Toxocara canis is important in order to develop better diagnostic techniques. Ten rabbits were infected orally with a dose of 5000 Toxocara canis embryonated eggs. Rabbits were bled periodically and an ELISA assay was performed to determine levels of specific Toxocara IgG antibodies. ELISA detected antibodies at day 15 after infection. Western blot (WB assay was performed using excretory/secretory antigens (E/S of T. canis second stage larvae. Different antigen concentrations were evaluated: 150, 200, 250 and 300 µg/mL. The concentration of 250 µg/mL was retained for analysis. Rabbit sera were diluted 1:100. Secondary antibody was used at a dilution of 1:1000. Results of WB indicated that in the first month after infection specific antibodies against the 200 KDa, 116 KDa, 92 KDa and 35 KDa antigens were detected; antibodies against the 92 KDa, 80 KDa, 66 KDa, 45 KDa, 31 KDa and 28 KDa antigens appeared later. All positive sera in the ELISA test were also positive in WB. Two antigen bands, 92 KDa and 35 KDa, were identified since the beginning and throughout the course of infection. These antigens merit further evaluation as candidates for use in diagnosis.

  20. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool.

    Science.gov (United States)

    Mesquita, Flávio da Silva; Oliveira, Danielle Bruna Leal de; Crema, Daniela; Pinez, Célia Miranda Nunes; Colmanetti, Thaís Cristina; Thomazelli, Luciano Matsumia; Gilio, Alfredo Elias; Vieira, Sandra Elisabeth; Martinez, Marina Baquerizo; Botosso, Viviane Fongaro; Durigon, Edison Luiz

    The aim of this study was to evaluate the QuickVue ® RSV Test Kit (QUIDEL Corp, CA, USA) as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue ® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. From 313 positive samples by immunofluorescence assays, 282 (90%) were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue ® RSV Test and viral load or specific strain. The QuickVue ® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. This study demonstrated that the QuickVue ® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Copyright © 2016 Sociedade Brasileira de Pediatria. Published by Elsevier Editora Ltda. All rights reserved.

  1. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool,

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    Full Text Available Abstract Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics.

  2. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    International Nuclear Information System (INIS)

    Wun, T.C.; Capuano, A.

    1987-01-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above

  3. Immunoradiometric quantitation of tissue plasminogen activator-related antigen in human plasma: crypticity phenomenon and relationship to plasma fibrinolysis

    Energy Technology Data Exchange (ETDEWEB)

    Wun, T.C.; Capuano, A.

    1987-05-01

    A two-site immunoradiometric assay for tissue plasminogen activator (tPA) antigen has been developed using immunoaffinity purified antibody. Various treatments enhanced the detection of tPA antigen in the plasma samples. Maximum detection was obtained by acidification of plasma to pH 4.8 to 6.5 or addition of 0.5 mol/L of L-lysine or L-arginine. Acidification or addition of lysine to plasma is also required for maximum immunoadsorption of plasma tPA antigen on anti-tPA-Ig-sepharose. These results indicate that plasma tPA antigen is partially cryptic to antibody in untreated plasma. The plasma tPA antigen isolated by immunoadsorption of either untreated plasma or acidified plasma on anti-tPA-Ig-sepharose consists mainly of a 100-kd plasminogen activator species as determined by fibrin-agar zymography. The 100-kd activity is possibly a tPA:inhibitor complex. A standardized sample preparation method was conveniently adopted by mixing 3 vol of plasma and 1 vol of 2 mol/L of L-lysine for the assay. Reconstitution and recovery studies showed that the method is specific and permits full detection of both free tPA and tPA:inhibitor complex. The validity of the assay is further supported by the finding that the spontaneous plasma fibrinolysis previously demonstrated to be dependent on plasma tPA antigen is correlated with tPA antigen content. Using the standardized assay, we found that tPA antigen concentrations in 16 blood bank plasmas are equivalent to 3.7 to 20 ng of 60 kd tPA/mL. In all the plasma tested, more than half of the antigen is undetected unless the plasma is treated as described above.

  4. Rapid enzyme-linked immunosorbent assay (ELISA) for Aspergillus fumigatus antibodies.

    OpenAIRE

    Richardson, M D; Stubbins, J M; Warnock, D W

    1982-01-01

    A rapid enzyme-linked immunosorbent assay (ELISA) where component incubation periods were shortened to one hour, was compared with agar gel double diffusion (AGDD) and a standard ELISA procedure for detecting antibodies to Aspergillus fumigatus in 28 asthmatic patients with suspected allergic aspergillosis. Using two A fumigatus antigens the rapid ELISA compared well with AGDD and the standard ELISA method. Eleven sera that reacted with both antigens in AGDD were all positive against antigen ...

  5. Purification and analyses of the specificity of two putative diagnostic antigens for larval cyathostomin infection in horses.

    Science.gov (United States)

    Dowdall, S M J; Proudman, C J; Love, S; Klei, T R; Matthews, J B

    2003-12-01

    Cyathostomins are important equine gastrointestinal parasites. Mass emergence of mucosal stage larvae causes a potentially fatal colitis. Mucosal stages are undetectable non-invasively. An assay that would estimate mucosal larval stage infection would greatly assist in treatment, control and prognosis. Previously, we identified two putative diagnostic antigens (20 and 25 kDa) in somatic larval preparations. Here, we describe their purification and antigen-specific IgG(T) responses to them. Western blots confirmed the purity of the antigens and showed that epitopes in the 20 kDa complex were specific to larval cyathostomins. No cross-reactive antigens appeared to be present in Parascaris equorum or Strongyloides westeri species. Low levels of cross-reactivity were observed in Strongylus edentatus and Strongylus vulgaris species. Use of purified antigens greatly reduced background binding in equine sera. These results indicate that both antigen complexes may be of use in a diagnostic assay.

  6. Microbead agglutination based assays

    KAUST Repository

    Kodzius, Rimantas

    2013-01-21

    We report a simple and rapid room temperature assay for point-of-care (POC) testing that is based on specific agglutination. Agglutination tests are based on aggregation of microbeads in the presence of a specific analyte thus enabling the macroscopic observation. Such tests are most often used to explore antibody-antigen reactions. Agglutination has been used for protein assays using a biotin/streptavidin system as well as a hybridization based assay. The agglutination systems are prone to selftermination of the linking analyte, prone to active site saturation and loss of agglomeration at high analyte concentrations. We investigated the molecular target/ligand interaction, explaining the common agglutination problems related to analyte self-termination, linkage of the analyte to the same bead instead of different microbeads. We classified the agglutination process into three kinds of assays: a two- component assay, a three-component assay and a stepped three- component assay. Although we compared these three kinds of assays for recognizing DNA and protein molecules, the assay can be used for virtually any molecule, including ions and metabolites. In total, the optimized assay permits detecting analytes with high sensitivity in a short time, 5 min, at room temperature. Such a system is appropriate for POC testing.

  7. Detection of soluble antigens of Toxoplasma gondii by a four-layer modification of an enzyme immunoassay.

    Science.gov (United States)

    Turunen, H J

    1983-01-01

    A sensitive four-layer modification of an enzyme immunoassay for the detection of soluble antigens of Toxoplasma gondii is described. Microtiter plates were sensitized with rabbit anti-toxoplasma immunoglobulins (6 micrograms/ml) used as the primary antibodies; guinea pig anti-toxoplasma immunoglobulins (6 micrograms/ml) were used as the secondary trapping antibodies. Horseradish peroxidase-conjugated anti-guinea pig immunoglobulins were used as the indicator antibodies. The specificity of the antigen assay was confirmed by using guinea pig immunoglobulins from preimmunization sera. The sensitivity of the antigen assay was found to be at least 10 ng of antigen protein per ml. The suitability of the method for detecting antigens of T. gondii in different specimens was studied by experimental toxoplasma infection in mice. Antigenic components of T. gondii could be detected in different tissue specimens from infected animals from the first day after infection onwards. Toxoplasma antigen in serum and urine samples from infected mice reached detectable levels on day 2 after infection followed by a linear increase in antigen concentration in succeeding samples. This method might offer a valuable aid for a rapid etiological diagnosis also in human cases of acute toxoplasmosis. PMID:6345574

  8. A novel double-isotope technique for the enzymatic assay of plasma histamine: application to estimation of mast cell activation assessed by antigen challenge in asthmatics

    International Nuclear Information System (INIS)

    Brown, M.J.; Ind, P.W.; Causon, R.; Lee, T.H.

    1982-01-01

    The concentration of plasma histamine may provide an index of mast cell activation (degranulation) and can be measured by a sensitive radioenzymatic assay based on its specific conversion to (/sup 3/H)-methylhistamine in the presence of histamine-N-methyltransferase and (/sup 3/H)-S-adenosyl-L-methionine. In this assay, the separation of excess (/sup 3/H)-S-adenosyl-L-methionine from (/sup 3/H)-methylhistamine requires several steps, for which a correction factors is necessary to maintain precision. In the present modification, duplicate 50-microliters aliquots of each plasma sample were incubated with histamine-N-methyltransferase and (/sup 3/H)-S-adenosyl-L-methionine. A further aliquot, with an added standard of 200 ng/ml histamine, was incubated with histamine-N-methyl-transferase and (/sup 14/C)-S-adenosyl-L-methionine. This standard was converted to (/sup 14/C)-methylhistamine, and its recovery at the end of the assay corrected both for varying efficiency of methylation among plasma samples and for losses during the subsequent extraction and separation stages. The sensitivity of the assay was 25 pg/ml. The intra-assay and interassay coefficients of variation were 7.2% and 11.6%, respectively. In five asthmatics, antigen challenge caused a 28% fall in FEV1, and this was associated with a twofold to threefold rise in plasma histamine concentration. This assay may thus prove a useful method for assessing the role of mast cell release of mediators in vivo

  9. Can resting B cells present antigen to T cells

    International Nuclear Information System (INIS)

    Ashwell, J.D.; DeFranco, A.L.; Paul, W.E.; Schwartz, R.H.

    1985-01-01

    Antigen stimulation of T lymphocytes can occur only in the presence of an antigen-presenting cell (APC). An ever-increasing number of cell types have been found to act as APCs; these include macrophages, splenic and lymph node dendritic cells, and Langerhans cells of the skin. Although activated B lymphocytes and B cell lymphomas are known to serve as APCs, it has been generally believed that resting B cells cannot perform this function. However, in recent studies the authors have found that resting B cells can indeed present soluble antigen to T cell clones as well as to antigen-primed T cells. The previous difficulty in demonstrating this activity can be explained by the finding that, in contrast to macrophages and dendritic cells, the antigen-presenting ability of resting B cells is very radiosensitive. Macrophages are usually irradiated with 2000-3300 rads to prevent them from incorporating [ 3 H]thymidine in the T cell proliferation assay. Resting B cells, however, begin to lose presenting function at 1500 rads and have completely lost this activity at 3300 rads. It was also possible to distinguish two distinct T cell clonal phenotypes when resting B cells were used as APCs on the basis of two different assays (T cell proliferation, and B cell proliferation resulting from T cell activation). The majority of T cell clones tested were capable of both proliferating themselves and inducing the proliferation of B cells. Some T cells clones, however, could not proliferate in the presence of antigen and B cell APCs, although they were very good at inducing the proliferation of B cells

  10. [Serological diagnosis of sporotrichosis using an antigen of Sporothrix schenckii sensu stricto mycelium].

    Science.gov (United States)

    Alvarado, Primavera; Ostos, Ana; Franquiz, Nohelys; Roschman-González, Antonio; Zambrano, Edgar A; Mendoza, Mireya

    2015-06-01

    We developed and analyzed an Enzyme-Linked Immunosorbent Assay (ELISA) in order to detect antibodies in sera from sporotrichosis patients. We used a crude antigen of Sporothrix schenckii sensu stricto, obtained from the mycelial phase of the fungi. Positive sera were analyzed by other serological techniques such as double immunodiffusion (IGG) and counterimmunoelectrophoresis (CIE). The assay was validated by using sera from patients with other pathologies such as: histoplasmosis, paracoccidioidomycosis, tuberculosis, leishmaniasis, lupus and healthy individuals as negative controls. For the Sporothrix schenckii sensu stricto antigen, we found a 100% of specificity by every technique and sensitivity higher than 98% with IDD, CIE and ELISA. Our results show a high sensitivity and specificity for the Sporothrix schenckii sensu stricto antigen, so it can be used for IDD, CIE and ELISA. The results suggest that this antigen could be used in conjunction with other conventional tests for differential diagnosis and may be useful for monitoring the disease progression and response to treatment.

  11. Determinants of wheat antigen and fungal alpha-amylase exposure in bakeries.

    Science.gov (United States)

    Burstyn, I; Teschke, K; Bartlett, K; Kennedy, S M

    1998-05-01

    The study's objectives were to measure flour antigen exposure in bakeries and define the determinants of exposure. Ninety-six bakery workers, employed in seven different bakeries, participated in the study. Two side-by-side full-shift inhalable dust samples were obtained from each study participant on a single occasion. The flour antigen exposure was measured as wheat antigen and fungal alpha-amylase content of the water-soluble fraction of inhalable dust, assayed via enzyme-linked immunosorbent assays. During the entire sampling period bakers were observed and information on 14 different tasks was recorded at 15-minute intervals. Other production characteristics were also recorded for each sampling day and used in statistical modeling to identify significant predictors of exposure. The mean alpha-amylase antigen exposure was 22.0 ng/m3 (ranging from below the limit of detection of 0.1 ng/m3 to 307.1 ng/m3) and the mean wheat antigen exposure was 109 micrograms/m3 (ranging from below the limit of detection of 1 microgram/m3 to 1018 micrograms/m3). Regression models that explained 74% of variability in wheat antigen and alpha-amylase antigen exposures were constructed. The models indicated that tasks such as weighing, pouring, and operating dough-brakers increased flour antigen exposure, while packing and decorating resulted in lower exposures. Croissant, puff-pastry, and bread/bun production lines were associated with increased exposure, while cake production and substitution of dusting with the use of divider oil were associated with decreased exposure. Exposure levels can be reduced by the automation of forming tasks, alteration of tasks requiring pouring of flour, and changes to the types of products manufactured.

  12. Isotopic methods or immuno diagnosis: The Radioimmunoassay and immunoradiometric assay

    International Nuclear Information System (INIS)

    Caso, R.

    1997-01-01

    This work offers an explanation about the more used isotopic techniques for immuno diagnosis: the radioimmunoassay (RIA) and immunoradiometric assay (IRMA). It describes the basic principles of these assays, the antigen-antibody reaction, the radioiodination methods with I-125 for antigens and antibodies, the purification and characterization of labelled compounds. On the order hand they present work gives a review of the methods for separate the bound and free fractions. At the end it offers the principles of the quality control of immunoassay and the future lines of research in the field of RIA and IRMA

  13. Multiplex real-time PCR for identification of canine parvovirus antigenic types.

    Science.gov (United States)

    Kaur, Gurpreet; Chandra, Mudit; Dwivedi, P N; Narang, Deepti

    2016-07-01

    Canine parvovirus (CPV) is an important disease causing gastroenteritis and/or haemorrhagic gastroenteritis in dogs. There are four antigenic types of CPV reported worldwide viz. CPV 2, CPV 2a, CPV 2b and CPV 2c. The diagnosis of CPV with the identification of the antigen type responsible remains problematic. In the present study, identification as well as antigenic typing of CPV was done using a de novo multiplex real time PCR to combat the problem of antigenic type identification. From the study it could be concluded that the here developed multiplex real time PCR assay could be used for rapid detection of CPV as well as typing of its three antigenic types. Copyright © 2016 Elsevier B.V. All rights reserved.

  14. Radioimmune assay of human platelet prostaglandin synthetase

    International Nuclear Information System (INIS)

    Roth, G.J.; Machuga, E.T.

    1982-01-01

    Normal platelet function depends, in part, on platelet PG synthesis. PG synthetase (cyclo-oxygenase) catalyzes the first step in PG synthesis, the formation of PGH 2 from arachidonic acid. Inhibition of the enzyme by ASA results in an abnormality in the platelet release reaction. Patients with pparent congenital abnormalities in the enzyme have been described, and the effects have been referred to as ''aspirin-like'' defects of the platelet function. These patients lack platelet PG synthetase activity, but the actual content of PG synthetase protein in these individuals' platelets is unknown. Therefore an RIA for human platelet PG synthetase would provide new information, useful in assessing the aspirin-like defects of platelet function. An RIA for human platelet PG synthetase is described. The assay utilizes a rabbit antibody directed against the enzyme and [ 125 I]-labelled sheep PG synthetase as antigen. The human platelet enzyme is assayed by its ability to inhibit precipitation of the [ 125 I]antigen. The assay is sensitive to 1 ng of enzyme. By the immune assay, human platelets contain approximately 1200 ng of PG synethetase protein per 1.5 mg of platelet protein (approximately 10 9 platelets). This content corresponds to 10,000 enzyme molecules per platelet. The assay provides a rapid and convenient assay for the human platelet enzyme, and it can be applied to the assessment of patients with apparent platelet PG synthetase (cyclo-oxygenase) deficiency

  15. Enhancement of Human Antigen-Specific Memory T-Cell Responses by Interleukin-7 May Improve Accuracy in Diagnosing Tuberculosis▿ †

    Science.gov (United States)

    Feske, Marsha; Nudelman, Rodolfo J.; Medina, Miguel; Lew, Justin; Singh, Manisha; Couturier, Jacob; Graviss, Edward A.; Lewis, Dorothy E.

    2008-01-01

    Children and immunocompromised adults are at an increased risk of tuberculosis (TB), but diagnosis is more challenging. Recently developed gamma interferon (IFN-γ) release assays provide increased sensitivity and specificity for diagnosis of latent TB, but their use is not FDA approved in immunocompromised or pediatric populations. Both populations have reduced numbers of T cells, which are major producers of IFN-γ. Interleukin 7 (IL-7), a survival cytokine, stabilizes IFN-γ message and increases protein production. IL-7 was added to antigen-stimulated lymphocytes to improve IFN-γ responses as measured by enzyme-linked immunosorbent assay (ELISA) and enzyme-linked immunospot (ELISPOT) assay. Antigens used were tetanus toxoid (n = 10), p24 (from human immunodeficiency virus [HIV], n = 9), and TB peptides (n = 15). Keyhole limpet hemocyanin was used as a negative control, and phytohemagglutinin was the positive control. IL-7 improved antigen-specific responses to all antigens tested including tetanus toxoid, HIV type 1 p24, and TB peptides (ESAT-6 and CFP-10) with up to a 14-fold increase (mean = 3.8), as measured by ELISA. Increased IFN-γ responses from controls, HIV-positive patients, and TB patients were statistically significant, with P values of <0.05, 0.01, and 0.05, respectively. ELISPOT assay results confirmed ELISA findings (P values of <0.01, 0.02, and 0.03, respectively), with a strong correlation between the two tests (R2 = 0.82 to 0.99). Based on average background levels, IL-7 increased detection of IFN-γ by 39% compared to the level with antigen alone. Increased production of IFN-γ induced by IL-7 improves sensitivity of ELISA and ELISPOT assays for all antigens tested. Further enhancement of IFN-γ-based assays might improve TB diagnosis in those populations at highest risk for TB. PMID:18753334

  16. Diagnostic efficacy of monoclonal antibody based sandwich enzyme linked immunosorbent assay (ELISA for detection of Fasciola gigantica excretory/secretory antigens in both serum and stool

    Directory of Open Access Journals (Sweden)

    Zoheiry Mona K

    2011-09-01

    Full Text Available Abstract Background This research was carried out to develop a reliable monoclonal antibody (MoAb-based sandwich enzyme linked immunosorbent assay (ELISA for the diagnosis of active Fasciola gigantica infection in both serum and stool for comparative purposes. Methods From a panel of MoAbs raised against F. gigantica excretory/secretory antigens (ES Ags, a pair (12B/11D/3F and 10A/9D/10G was chosen due to its high reactivity and strict specificity to F. gigantica antigen by indirect ELISA. Results The two MoAbs were of the IgG1 and IgG2a subclasses, respectively. Using SDS-PAGE and EITB, the selected MoAbs recognized 83, 64, 45 and 26 kDa bands of ES Ags. The lower detection limit of ELISA assay was 3 ng/ml. In stool, the sensitivity, specificity and diagnostic efficacy of ELISA was 96%, 98.2 and 97.1%; while in serum they were 94%, 94.6% and 94.3%, respectively. Moreover, a positive correlation was found between ova count in stool of F. gigantica infected patients and the OD readings of ELISA in both stool and serum samples (r = 0.730, p Conclusions These data showed that the use of MoAb-based sandwich ELISA for the detection of F. gigantica coproantigens in stool specimens was superior to serum samples; it provides a highly efficient, non-invasive technique for the diagnosis of active F. gigantica infection.

  17. Characterization of the Apa antigen from M. avium subsp. paratuberculosis: a conserved Mycobacterium antigen that elicits a strong humoral response in cattle.

    Science.gov (United States)

    Gioffré, A; Echeverría-Valencia, G; Arese, A; Morsella, C; Garbaccio, S; Delgado, F; Zumárraga, M; Paolicchi, F; Cataldi, A; Romano, M I

    2009-12-15

    Johne's disease or paratuberculosis is widespread in almost all countries and remains difficult to eradicate. Nowadays, diagnosis of Mycobacterium avium subsp. paratuberculosis (MPTB) infection is one of the main concerns. In this work, we evaluated the expression, biochemical properties and antigenicity of the Apa antigen, encoded by the gene annotated as MAP1569, in the MPTB genome. We confirmed its expression in MPTB and its glycosylation by the ConA binding assay. Although the MPTB-Apa is not an immunodominant antigen, MPTB-infected cattle showed a strong humoral response to recombinant Apa by Western blot and ELISA. Milk was also a suitable sample to be tested by ELISA. We comparatively analysed the humoral cross-reactivity to the Apa from MPTB (MPTB-Apa) and the orthologue from Mycobacterium tuberculosis (MT-Apa, identical to that from Mycobacterium bovis) in both infected and control cows. Response of M. bovis- and MPTB-infected animals against MT-Apa was similar (P=0.6985) but the response of the M. bovis-infected ones to MPTB-Apa was differential, being significantly diminished (PApa stimulation in the IFNgamma release assay, we found no significant differences when compared infected herds with non-infected ones (P=0.34). This antigen, in contrast to bovine Purified Protein Derivative (PPDb), was strongly represented in avian PPD (PPDa), as shown by the recognition of BALB/c mice hyperimmune sera against MPTB-Apa by Dot-blot immunoassay. We therefore demonstrated the antigenicity of Apa in MPTB-infected animals and a differential response to the recombinant antigen when compared to M. bovis-infected animals. These traits herein described, added to the usefulness of milk samples to detect IgG anti-Apa, could be important for routine screening in dairy cattle, considering a multiantigenic approach to overcome the lack of immunodominance.

  18. Radioimmunometric assay of carbohydrate antigen 549 in diagnosis and follow-up of breast carcinoma

    International Nuclear Information System (INIS)

    Hervas, I.; Gonzalez-Cabezas, P.; Flores, D.; Perez-Pastor, J.L.; Bello, P.; Perez-Velasco, R.; Torres, I.; Olivas, C.; Mateo, A.

    2002-01-01

    Aim: The aim of this study is to assess the value of carbohydrate antigen 549 (CA 549) in diagnosis and follow-up of breast carcinoma and compare CA 549 with other tumoral markers. Methods: A. We have studied 1230 determinations of CA 549 corresponding to 460 patients (3 male) with confirmed or suspected diagnosis of breast carcinoma. CA 549 was determined using a radioimmunometric assay that use a 'sandwich' technique on solid phase. B. To compare CA 549 with other tumoral markers we have reviewed the case history of 40 patients with advanced breast carcinoma. The tumoral markers studied were: CEA, CA 19.9, CA 15.3 and CA 549. C. We have performed a correlation study between the different tumoral markers on 124 evaluations and calculated the Pearson's correlation coefficient. Results: In the group of confirmed or suspected diagnosis of breast carcinoma (n=460): 187 patients (40,65%) showed pathological levels of CA 549. In the group of patients with advanced breast carcinoma (36 patients with metastasis and 4 with advanced local extension). the results of the different tumoral markers are presented. The Pearson's correlation coefficient between CA 549 and CA 15.3 was 0.814, while no correlation was found in the remaining markers. Conclusion: CA 549 is a good marker of progression or persistence of tumoral disease in breast carcinoma

  19. Comparative efficacy of antigen and antibody detection tests for human trichinellosis

    International Nuclear Information System (INIS)

    Ivanoska, D.; Cuperlovic, K.; Gamble, H.R.; Murrell, K.D.

    1989-01-01

    Sera collected from patients with suspected or confirmed exposure to Trichinella spiralis were tested for circulating parasite antigens and antiparasite antibodies. Using an immunoradiometric assay, excretory--secretory antigens from muscle-stage larvae of T. spiralis were detected in the sera of 47% of 62 patients with clinical trichinellosis and 13% of 39 patients without clinical signs but suspected of exposure to infected meat. In comparison, antibodies were detected using an indirect immunofluorescent test in the circulation of 100% of the 62 patients with clinical trichinellosis and 46% of the 39 patients with suspected exposure. The presence of antibodies specific to excretory-secretory products of T. spiralis muscle larvae was confirmed in the majority of the samples tested by a monoclonal antibody-based competitive inhibition assay. These results indicate that antibody detection is a more sensitive diagnostic method for human trichinellosis, but that antigen detection might be a useful confirmatory test because it is a direct demonstration of parasite products in the circulation

  20. Immunoliposome-PCR: a generic ultrasensitive quantitative antigen detection system

    Directory of Open Access Journals (Sweden)

    He Junkun

    2012-06-01

    Full Text Available Abstract Background The accurate quantification of antigens at low concentrations over a wide dynamic range is needed for identifying biomarkers associated with disease and detecting protein interactions in high-throughput microarrays used in proteomics. Here we report the development of an ultrasensitive quantitative assay format called immunoliposome polymerase chain reaction (ILPCR that fulfills these requirements. This method uses a liposome, with reporter DNA encapsulated inside and biotin-labeled polyethylene glycol (PEG phospholipid conjugates incorporated into the outer surface of the liposome, as a detection reagent. The antigenic target is immobilized in the well of a microplate by a capture antibody and the liposome detection reagent is then coupled to a biotin-labeled second antibody through a NeutrAvidin bridge. The liposome is ruptured to release the reporter DNA, which serves as a surrogate to quantify the protein target using real-time PCR. Results A liposome detection reagent was prepared, which consisted of a population of liposomes ~120 nm in diameter with each liposome possessing ~800 accessible biotin receptors and ~220 encapsulated reporters. This liposome detection reagent was used in an assay to quantify the concentration of carcinoembryonic antigen (CEA in human serum. This ILPCR assay exhibited a linear dose–response curve from 10-10 M to 10-16 M CEA. Within this range the assay coefficient of variance was Conclusions The ILPCR assay has several advantages over other immuno-PCR methods. The reporter DNA and biotin-labeled PEG phospholipids spontaneously incorporate into the liposomes as they form, simplifying preparation of the detection reagent. Encapsulation of the reporter inside the liposomes allows nonspecific DNA in the assay medium to be degraded with DNase I prior to quantification of the encapsulated reporter by PCR, which reduces false-positive results and improves quantitative accuracy. The ability to

  1. The use of a synthetic antigen for the serological diagnosis of human trichinellosis

    Directory of Open Access Journals (Sweden)

    Bruschi F.

    2001-06-01

    Full Text Available Hosts infected with Trichinella produce antibodies specific for an epitope common to the TSL-1 family antigens. This epitope contained uncommon terminal 3, 6-dideoxy-D-arabinohexose (so called tyvelose residues. The disaccharide moiety was synthesized and an immunodiagnostic assay was developed, which was specific and sensitive in swine trichinellosis. We aimed to verify the specificity and sensitivity of this immunodiagnostic test in human trichinellosis. 15 sera from normal subjects, 12 from patients with other parasitic diseases and 50 from trichinellosis patients were tested. Indirect enzyme linked immunosorbent assay (ELISA for specific IgG and an amplified ELISA for specific IgE were performed using β-tyvelose-GalNAc-bovine serum albumin (BSA disaccharide conjugate or T. spiralis muscle larvae excretory/secretory (E/S products, as antigens. Neither control sera nor other parasitic infection sera resulted positive both for IgG and IgE when synthetic or E/S antigens were used. In trichinellosis patient sera, specific IgG were present in 100 % of cases, irrespective of the antigen used, but whereas specific IgE were detected in 78 % using E/S antigens, a 100% positivity rate was obtained, using the β-tyvelose- BSA conjugate.

  2. Highly sensitive solid-phase radioimmunoassay for the assay of Plasmodium falciparum antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D. (Hebrew Univ., Jerusalem (Israel). Hadassah Medical School)

    1982-08-27

    A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10/sup 6/ RBC.

  3. Antigenic characterisation of yeast-expressed lyssavirus nucleoproteins.

    Science.gov (United States)

    Kucinskaite, Indre; Juozapaitis, Mindaugas; Serva, Andrius; Zvirbliene, Aurelija; Johnson, Nicholas; Staniulis, Juozas; Fooks, Anthony R; Müller, Thomas; Sasnauskas, Kestutis; Ulrich, Rainer G

    2007-12-01

    In Europe, three genotypes of the genus Lyssavirus, family Rhabdoviridae, are present, classical rabies virus (RABV, genotype 1), European bat lyssavirus type 1 (EBLV-1, genotype 5) and European bat lyssavirus type 2 (EBLV-2, genotype 6). The entire authentic nucleoprotein (N protein) encoding sequences of RABV (challenge virus standard, CVS, strain), EBLV-1 and EBLV-2 were expressed in yeast Saccharomyces cerevisiae at high level. Purification of recombinant N proteins by caesium chloride gradient centrifugation resulted in yields between 14-17, 25-29 and 18-20 mg/l of induced yeast culture for RABV-CVS, EBLV-1 and EBLV-2, respectively. The purified N proteins were evaluated by negative staining electron microscopy, which revealed the formation of nucleocapsid-like structures. The antigenic conformation of the N proteins was investigated for their reactivity with monoclonal antibodies (mAbs) directed against different lyssaviruses. The reactivity pattern of each mAb was virtually identical between immunofluorescence assay with virus-infected cells, and ELISA and dot blot assay using the corresponding recombinant N proteins. These observations lead us to conclude that yeast-expressed lyssavirus N proteins share antigenic properties with naturally expressed virus protein. These recombinant proteins have the potential for use as components of serological assays for lyssaviruses.

  4. New developments in the standardization of total prostate-specific antigen.

    Science.gov (United States)

    Blijenberg, B G; Storm, B N; Van Zelst, B D; Kruger, A E; Schröder, F H

    1999-11-01

    Analytical evaluation of the calibration of three recently launched assays for the measurement of total prostate-specific antigen, i.e., IMx Total PSA (Abbott), Elecsys PSA (Roche), and IMMULITE 3rd Generation PSA (DPC). For accuracy assessment two reference materials were applied namely, Stanford 90:10 PSA Calibrator and Certified Reference Material 613 Prostate-Specific Antigen. Dilutions of these preparations were analyzed with all assays. In addition, clinical specimens from known prostate cancer or benign prostate hyperplasia patients and samples taken from an ongoing prostate cancer screening study were used for comparison. Application of the Stanford Calibrator revealed results well within 10% of the calculated values for all assays. Regarding the CRM Calibrator only the IMx Total PSA proved to approach the line of identity. The IMMULITE results differed about 40% and the Elecsys about 18% from the calculated values. The comparison with clinical specimens showed statistically different results for the combination IMMULITE-IMx and for IMMULITE-Elecsys. The regression lines for both collections were: y(IMx) = 0.86x(IMMULITE) +0.12 (n = 104, r = 0.970, Sy/x = 0.883 microg/L) and y(Elecsys) = 0.98x(IMMULITE) +0.38 (n = 97, r = 0.976, Sy/x = 0.733 microg/L). In the lower measuring range (PSA differences were less pronounced. In analytical sense a difference was found for both reference preparations in the assays studied. Clinically, despite improvements in methodology, results for total prostate-specific antigen are still not interchangeable. The possible consequences need to be elaborated.

  5. Pi overlapping ring systems contained in a homogeneous assay: a novel homogeneous assay for antigens

    Science.gov (United States)

    Kidwell, David A.

    1993-05-01

    A novel immunoassay, Pi overlapping ring systems contained in a homogeneous assay (PORSCHA), is described. This assay relies upon the change in fluorescent spectral properties that pyrene and its derivatives show with varying concentration. Because antibodies and other biomolecules can bind two molecules simultaneously, they can change the local concentration of the molecules that they bind. This concentration change may be detected spectrally as a change in the fluorescence emission wavelength of an appropriately labeled biomolecule. Several tests of PORSCHA have been performed which demonstrate this principle. For example: with streptavidin as the binding biomolecule and a biotin labeled pyrene derivative, the production of the excimer emitting at 470 nm is observed. Without the streptavidin present, only the monomer emitting at 378 and 390 nm is observed. The ratio of monomer to excimer provides the concentration of unlabeled biotin in the sample. Approximately 1 ng/mL of biotin may be detected with this system using a 50 (mu) l sample (2 X 10-16 moles biotin). The principles behind PORSCHA, the results with the streptavidin/biotin system are discussed and extensions of the PORSCHA concept to antibodies as the binding partner and DNA in homogeneous assays are suggested.

  6. Enhancement of human natural cytotoxicity by Plasmodium falciparum antigen activated lymphocytes

    DEFF Research Database (Denmark)

    Theander, T G; Pedersen, B K; Bygbjerg, I C

    1987-01-01

    Mononuclear cells (MNC) isolated from malaria immune donors and from donors never exposed to malaria were stimulated in vitro with soluble purified Plasmodium falciparum antigens (SPag) or PPD. After 7 days of culture the proliferative response and the cytotoxic activity against the natural killer...... were preincubated with interleukin 2 (IL-2) for one hour before the start of the cytotoxic assay. SPag activation did not enhance the cytotoxic activity of MNC which did not respond to the antigen in the proliferation assay, and preincubation of these cells with IL-2 did not increase the activity. PPD...

  7. Evaluation of two Taenia solium cysticercal antigenic preparations (vesicular fluid and a glycoprotein fraction with affinity for lentil lectin for the immunodiagnosis of neurocysticercosis by enzyme-linked immunosorbent assay (ELISA

    Directory of Open Access Journals (Sweden)

    Lisandra Akemi Suzuki

    2011-06-01

    Full Text Available OBJECTIVE: To evaluate the performance of two antigenic preparations (vesicular fluid - VF and a glycoprotein fraction, LLa-Gp fraction, purified from a whole parasite extract by lentil lectin affinity chromatography from Taenia solium cysticerci for the immunodiagnosis of neurocysticercosis. METHOD: Fifty-six cerebrospinal fluid (CSF samples (22 from patients with neurocysticercosis and 34 from patients with other neurological disorders and 57 serum samples (22 from patients with neurocysticercosis, 18 from patients with other infections and 17 from presumably healthy persons were assayed for anticysticercal IgG antibodies with an enzyme-linked immunosorbent assay (ELISA. RESULTS: The VF ELISA showed 100% sensitivity and specificity in CSF and serum samples, whereas the sensitivity and specificity of the LLa-Gp ELISA were, respectively, 90.9% and 97.1%, with the CSF samples and 95.5% and 100% with serum samples. There was no significant difference in the sensitivity and specificity of the two antigenic preparations used to screen CSF and serum samples. CONCLUSION: Considering the complexity and high cost of obtaining the LLa-Gp fraction, VF could be more suitable for screening specific antibodies by ELISA in CSF and serum samples from patients with neurocysticercosis.

  8. Penggunaan Crude Antigen Cysticercus cellulosae Isolat Bali Untuk Optimalisasi Uji ELISA

    Directory of Open Access Journals (Sweden)

    Inti Sari Pati R U Sianturi

    2017-01-01

    Full Text Available Sistiserkosis merupakan penyakit parasitik yang disebabkan oleh larva stadium metacestoda dari cacing pita yang disebut Cysticercus.  Cysticercus yang ditemukan pada babi adalah Cysticercus cellulosae yang merupakan larva dari cacing pita Taenia solium. Penelitian ini dilakukan dengan tujuan mengevaluasi antigen crude Cysticercus cellulosae untuk mendeteksi sistiserkosis pada babi. Cysticercus celllulosae yang digunakan adalah isolat lokal yang diperoleh dari babi terinfeksi Taenia solium asal Karangasem-Bali. Penelitian dilakukan untuk optimalisasi ELISA (Enzyme Linked Immunosorbent Assay terhadap antigen, serum, dan konjugat dengan cara mencari konsentrasi optimal dari antigen, pengenceran optimal serum, dan pengenceran optimal konjugat. Hasil penelitian didapatkan bahwa crude antigen Cysticercus cellulosae isolat Bali bersifat antigenik dan dapat digunakan untuk mendeteksi sistiserkosis pada babi dengan konsentrasi optimal antigen 0,3125 µg/ml, pengenceran optimal serum 1:50, dan pengenceran konjugat 1:2000.

  9. Immunoassay of poliovirus antigens by single-radial-diffusion: development and characteristics of a sensitive autoradiographic zone size enhancement (ZE) technique

    International Nuclear Information System (INIS)

    Schild, G.C.; Wood, J.M.; Minor, P.D.; Dandawate, C.N.; Magrath, D.I.

    1980-01-01

    The reactions of polioviruses in single-radial-immunodiffusion (SRD) tests were investigated with a view to developing accurate and sensitive antigen assay systems. In direct SRD tests, the reactions were type-specific for polioviruses of types 1, 2 and 3 but the tests were of low sensitivity, being applicable only to the assay of virus concentrates. A novel autoradiographic zone size enhancement (ZE) test was developed which increased the sensitivity of the SRD assay 40-to 100-fold. The ZE test was dependent upon the ability of unlabelled poliovirus to co-migrate with the radioactive marker virus and so enhance the zone size detected autoradiographically. The areas of the autoradiographic zones were directly proportional to the concentration of unlabelled antigen. The ZE test was capable of detecting poliovirus D antigens in amounts corresponding to 10sup(3.3) to 10sup(4.3) TCID 50 of infectious virus. Studies with poliovirus type 3 strains indicated that the ZE test was narrowly strain-specific for the D-antigen of poliovirus type 3 strains when homologous type 3 D-antigen was used as radioactive marker, but broadly cross-reactive for the D-antigen of type 3 viruses when heterologous poliovirus type 3 D-antigen was used as marker. (author)

  10. Rotor assembly and assay method

    Science.gov (United States)

    Burtis, C.A.; Johnson, W.F.; Walker, W.A.

    1993-09-07

    A rotor assembly for carrying out an assay includes a rotor body which is rotatable about an axis of rotation, and has a central chamber and first, second, third, fourth, fifth, and sixth chambers which are in communication with and radiate from the central chamber. The rotor assembly further includes a shuttle which is movable through the central chamber and insertable into any of the chambers, the shuttle including a reaction cup carrying an immobilized antigen or an antibody for transport among the chambers. A method for carrying out an assay using the rotor assembly includes moving the reaction cup among the six chambers by passing the cup through the central chamber between centrifugation steps in order to perform the steps of: separating plasma from blood cells, binding plasma antibody or antigen, washing, drying, binding enzyme conjugate, reacting with enzyme substrate and optically comparing the resulting reaction product with unreacted enzyme substrate solution. The movement of the reaction cup can be provided by attaching a magnet to the reaction cup and supplying a moving magnetic field to the rotor. 34 figures.

  11. Cell surface antigens of radiation leukemia virus-induced BALB/c leukemias defined by syngeneic cytotoxic T lymphocytes

    International Nuclear Information System (INIS)

    Kaneko, Yukio; Oettgen, H.F.; Obata, Yuichi; Nakayama, Eiichi.

    1989-01-01

    Two cell surface antigens of mouse leukemias were defined by BALB/c cytotoxic T lymphocytes (CTL) generated against syngeneic radiation leukemia virus (RadLV)-induced leukemia, BALBRV1 or BALBRVD. Hyperimmunization of BALB/c mice with irradiated leukemias followed by in vitro sensitization of primed spleen cells resulted in the generation of CTL with high killing activity. The specificity of CTL was examined by direct cytotoxicity assays and competitive inhibition assays. A shared cell surface antigen, designated as BALBRV1 antigen, was detected by BALB/c anti-BALBRV1 CTL. BALBRV1 antigen was expressed not only on RadLV-induced BALB/c leukemias except for BALBRVD, but also on spontaneous or X-ray-induced BALB/c leukemias, chemically-induced leukemias with the H-2 d haplotype and some chemically-induced BALB/c sarcomas. In contrast, a unique cell surface antigen, designated as BALBRVD antigen, was detected by BALB/c anti-BALBRVD CTL. BALBRVD antigen was expressed only on BALBRVD, but not on thirty-nine normal lymphoid or tumor cells. These two antigens could be distinguished from those previously defined on Friend, Moloney, Rauscher or Gross murine leukemia virus (MuLV) leukemias, or MuLV-related antigens. Both cytotoxic responses were blocked by antisera against H-2K d , but not H-2D d . The relationship of BALBRV1 antigen and BALBRVD antigen to endogenous MuLV is discussed with regard to the antigenic distribution on tumor cell lines. (author)

  12. Chemiluminescence immunoassay for prostate-specific antigen

    International Nuclear Information System (INIS)

    Zhang Xuefeng; Liu Yibing; Jia Juanjuan; Xu Wenge; Li Ziying; Chen Yongli; Han Shiquan

    2008-01-01

    The chemiluminescence immunoassay (CLIA) for serum total prostate-specific antigen (T-PSA) was developed. The reaction of luminol with hydrogen peroxide was introduced into this chemiluminescence system. The detection limit is established as 0.12 μg/L (n=10, mean of zero standard + 2SD) and the analytical recovery of PSA is 83.8%-118.7%. The intra-assay and inter-assay CVs vary from 4.4%-5.0% and 6.2%-11.7%, respectively. The experimental correlation coefficient of dilution is found to be 0.999. Compared with immunoradiometric assay (IRMA) kits, the correlative equation is y=1.07x+0.68, and correlation coefficient r=0.97. The standard range for the method is 1.5-80 μg/L, and it presents good linearity. (authors)

  13. Development of Two FhSAP2 Recombinant–Based Assays for Immunodiagnosis of Human Chronic Fascioliasis

    Science.gov (United States)

    Shin, Sun Hee; Hsu, Angel; Chastain, Holly M.; Cruz, Lorna A.; Elder, Eric S.; Sapp, Sarah G. H.; McAuliffe, Isabel; Espino, Ana M.; Handali, Sukwan

    2016-01-01

    In the United States, infection with Fasciola hepatica has been identified as an emerging disease, primarily in immigrants, refugees, and travelers. The laboratory test of choice for diagnosis of fascioliasis is detection of disease specific antibodies, most commonly uses excretory-secretory antigens for detection of IgG antibodies. Recently, recombinant proteins such as F. hepatica antigen (FhSAP2) have been used to detect IgG antibodies. The glutathione S-transferase (GST)–FhSAP2 recombinant antigen was used to develop Western blot (WB) and fluorescent bead-based (Luminex) assays to detect F. hepatica total IgG and IgG4 antibodies. The sensitivity and specificity of GST-FhSAP2 total IgG and IgG4 WB were similar at 94% and 98%, respectively. For the IgG Luminex assay, the sensitivity and specificity were 94% and 97%, and for the IgG4, the values were 100% and 99%, respectively. In conclusion, the GST-FhSAP2 antigen performs well in several assay formats and can be used for clinical diagnosis. PMID:27549636

  14. Development of Two FhSAP2 Recombinant-Based Assays for Immunodiagnosis of Human Chronic Fascioliasis.

    Science.gov (United States)

    Shin, Sun Hee; Hsu, Angel; Chastain, Holly M; Cruz, Lorna A; Elder, Eric S; Sapp, Sarah G H; McAuliffe, Isabel; Espino, Ana M; Handali, Sukwan

    2016-10-05

    In the United States, infection with Fasciola hepatica has been identified as an emerging disease, primarily in immigrants, refugees, and travelers. The laboratory test of choice for diagnosis of fascioliasis is detection of disease specific antibodies, most commonly uses excretory-secretory antigens for detection of IgG antibodies. Recently, recombinant proteins such as F. hepatica antigen (FhSAP2) have been used to detect IgG antibodies. The glutathione S-transferase (GST)-FhSAP2 recombinant antigen was used to develop Western blot (WB) and fluorescent bead-based (Luminex) assays to detect F. hepatica total IgG and IgG 4 antibodies. The sensitivity and specificity of GST-FhSAP2 total IgG and IgG 4 WB were similar at 94% and 98%, respectively. For the IgG Luminex assay, the sensitivity and specificity were 94% and 97%, and for the IgG 4 , the values were 100% and 99%, respectively. In conclusion, the GST-FhSAP2 antigen performs well in several assay formats and can be used for clinical diagnosis. © The American Society of Tropical Medicine and Hygiene.

  15. COMPARISONS OF ELISA AND WESTERN BLOT ASSAYS FOR DETECTION OF CRYPTOSPORIDIUM ANTIBODY

    Science.gov (United States)

    A seroprevalence survey was conducted using ELISA and Western blot (WB) assays for antibody to three Cryptosporidium antigens on 380 blood donors in Jackson County, Oregon. The purpose was to determine if either assay could detect serological evidence of an outbreak which occurre...

  16. The hybrid EIA test: a specific and sensitive assay for the detection of woodchuck antibody to hepatitis surface antigen (anti-WHs).

    Science.gov (United States)

    Millman, I; Glass, R G

    1988-05-01

    'Ausria II' polystyrene beads (Abbott Labs, N. Chicago) are reacted with woodchuck serum positive for WHsAg in a dilution predetermined by titration. This modified bead is used in a blocking assay to detect the presence of antibody to the surface antigen of woodchuck hepatitis virus (anti-WHs). Serum containing woodchuck anti-WHs and commercial horseradish peroxidase (HRP) labeled anti-HBs are sequentially added. A drop in optical density at 492 nm of 50% or more due to the blocking of HRP conjugated anti-HBs by anti-WHs compared with a control (negative woodchuck serum) is a measure of anti-WHs. The ease and simplicity of converting readily available 'Ausria II' beads to specific reagents for detecting anti-WHs should be welcomed by investigators studying WHV. The method described is both sensitive and reproducible.

  17. The effect of high antigen density on solid-phase radioimmunoassays for antibody regardless of immunoglobulin class

    International Nuclear Information System (INIS)

    Rubin, R.L.; Hardtke, M.A.; Carr, R.I.

    1980-01-01

    Human sera containing antibody to casein or to bovine serum albumin were used to assess the validity and utility of a solid-phase assay for quantitating antibody activity. Rabbit anti-human immunoglobulin radiolabeled with 125 I and capable of reacting with all human immunoglobulin classes was used to detect antibody bound to antigen immobilized to polystyrene tubes by a new covalent technique. This method results in very high antigen concentrations in highly stable association with polystyrene tubes. Kinetic and absorption studies demonstrated that low avidity antibodies are better detected when antigen is immobilized by the covalent method than when passively adsorbed. Conditions are described for minimizing artifactual interactions and for obtaining results similar to those obtained with conventional, liquid-phase assays. Failure to reach equilibrium in solid-phase assays and other problems are proposed to explain, in part, the inability to obtain a better correlation between solid- and liquid-phase immunoassays. (Auth.)

  18. Mycobacterium leprae antigens involved in human immune responses. I. Identification of four antigens by monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Britton, W.J.; Hellqvist, L.; Basten, A.; Raison, R.L.

    1985-12-01

    Four distinct antigens were identified in soluble sonicates of Mycobacterium leprae by using a panel of 11 monoclonal antibodies. Cross-reactivity studies with other mycobacterial species were conducted by using ELISA and immunoblot assays, and demonstrated that determinants on two of the antigens were present in many mycobacteria, whereas the other two were limited in distribution. Competitive inhibition experiments with radiolabeled monoclonal antibodies showed cross-inhibition between antibodies identifying two of the four antigenicbands. These two bands, of M/sub tau/ 4.5 to 6 KD and 30 to 40 KD, were resistant to protease treatment after immunoblotting. In contrast the two other bands of 16 and 70 KD were protease-sensitive. Although all four bands reacted with some human lepromatous leprosy sera in immunoblots, the 4.5 to 6 KD and 30 to 40 KD bands were most prominent. Lepromatous leprosy sera also inhibited the binding of radiolabeled monoclonal antibodies to each of the four antigens, with the mean titer causing 50% inhibition being higher for antibodies reacting with the 4.5 to 6 KD and 30 to 40 KD bands. These findings indicated that all four antigens were involved in the human B cell response to M. leprae.

  19. Mycobacterium leprae antigens involved in human immune responses. I. Identification of four antigens by monoclonal antibodies

    International Nuclear Information System (INIS)

    Britton, W.J.; Hellqvist, L.; Basten, A.; Raison, R.L.

    1985-01-01

    Four distinct antigens were identified in soluble sonicates of Mycobacterium leprae by using a panel of 11 monoclonal antibodies. Cross-reactivity studies with other mycobacterial species were conducted by using ELISA and immunoblot assays, and demonstrated that determinants on two of the antigens were present in many mycobacteria, whereas the other two were limited in distribution. Competitive inhibition experiments with radiolabeled monoclonal antibodies showed cross-inhibition between antibodies identifying two of the four antigenicbands. These two bands, of M/sub tau/ 4.5 to 6 KD and 30 to 40 KD, were resistant to protease treatment after immunoblotting. In contrast the two other bands of 16 and 70 KD were protease-sensitive. Although all four bands reacted with some human lepromatous leprosy sera in immunoblots, the 4.5 to 6 KD and 30 to 40 KD bands were most prominent. Lepromatous leprosy sera also inhibited the binding of radiolabeled monoclonal antibodies to each of the four antigens, with the mean titer causing 50% inhibition being higher for antibodies reacting with the 4.5 to 6 KD and 30 to 40 KD bands. These findings indicated that all four antigens were involved in the human B cell response to M. leprae

  20. Antigen delivery by α2-macroglobulin enhances the cytotoxic T lymphocyte response

    Science.gov (United States)

    Bowers, Edith V.; Horvath, Jeffrey J.; Bond, Jennifer E.; Cianciolo, George J.; Pizzo, Salvatore V.

    2009-01-01

    α2M* targets antigens to APCs for rapid internalization, processing, and presentation. When used as an antigen-delivery vehicle, α2M* amplifies MHC class II presentation, as demonstrated by increased antibody titers. Recent evidence, however, suggests that α2M* encapsulation may also enhance antigen-specific CTL immunity. In this study, we demonstrate that α2M*-delivered antigen (OVA) enhances the production of specific in vitro and in vivo CTL responses. Murine splenocytes expressing a transgenic TCR specific for CTL peptide OVA257–264 (SIINFEKL) demonstrated up to 25-fold greater IFN-γ and IL-2 secretion when treated in vitro with α2M*-OVA compared with soluble OVA. The frequency of IFN-γ-producing cells was increased ∼15-fold, as measured by ELISPOT. Expansion of the OVA-specific CD8+ T cell population, as assayed by tetramer binding and [3H]thymidine incorporation, and OVA-specific cell-mediated cytotoxicity, as determined by a flow cytometric assay, were also enhanced significantly by α2M*-OVA. Furthermore, significant CTL responses were observed at antigen doses tenfold lower than those required with OVA alone. Finally, we also observed enhanced humoral and CTL responses by naïve mice following intradermal immunization with α2M*-OVA. These α2M*-OVA-immunized mice demonstrated increased protection against a s.c.-implanted, OVA-expressing tumor, as demonstrated by delayed tumor growth and prolonged animal survival. The observation that α2M*-mediated antigen delivery elicits specific CTL responses suggests the cross-presentation of antigen onto MHC class I. These results support α2M* as an effective antigen-delivery system that may be particularly useful for vaccines based on weakly immunogenic subunits or requiring dose sparing. PMID:19652028

  1. Use of radioimmune assay in investigating reagents to be used in the immunocytochemical localization of hepatitis B surface antigen in immune complexes in the kidney of patients with membranous nephropathy and Australia antigenaemia

    Energy Technology Data Exchange (ETDEWEB)

    Wolfe-Coote, S [South African Medical Research Council, Tygerberg (South Africa). Inst. for Electron Microscopy

    1983-09-01

    Radioimmune assay (RIA) was used to investigate the effect of fixatives on antigenicity of the hepatitis B surface antigen (HBsAg) and the effect of pronase on the elution of antibody (Ab) from the HBsAg-Ab complex. The effect of pronase on Ab elution was also tested on sections of kidney from a patient with the immune complex disease systemic lupus erythematosus (SLE). Immunoglobulin G (IgG) was located in pronase treated and untreated sections using the indirect immunoperoxidase technique. Glutareldehyde was shown to be the fixative of choice for studies involving HBsAg. All fixatives were shown to have less effect on antigenicity at 4/sup 0/C than at room temperature. Osmium tetroxide reduced antigenicity to one-third, even at 4/sup 0/C. RIA and SLE kidney section studies showed that Ab was eluted from immune complexes by pronase. Pre-fixation of the antigen (Ag) by glutaraldehyde appears to have no effect on the final elution, although fixation after pronase treatment seemed to enhance the elution effects. The availability of an RIA kit with HBsAg- and Ab-coated beads was of great assistance in evaluating reagents to be used in immunoperoxidase studies of HBsAg in immune complexes of patients with membranous nephropathy and Australia antigenaemia.

  2. “New” Antigenic Targets and Methodological Approaches for Refining Laboratory Diagnosis of Antiphospholipid Syndrome

    Science.gov (United States)

    Misasi, Roberta; Capozzi, Antonella; Longo, Agostina; Recalchi, Serena; Lococo, Emanuela; Alessandri, Cristiano; Conti, Fabrizio; Valesini, Guido

    2015-01-01

    Antiphospholipid antibodies (aPLs) are a heterogeneous group of antibodies directed against phospholipids or protein/phospholipid complexes. Currently, aPLs are assessed using either “solid-phase” assays that identify anticardiolipin antibodies and anti-β2-glycoprotein I antibodies or “liquid-phase” assay that identifies lupus anticoagulant. However, in the last few years, “new” antigenic targets and methodological approaches have been employed for refining laboratory diagnosis of antiphospholipid syndrome (APS). In this review the potential diagnostic value of antibodies to domains of β2-GPI, prothrombin/phosphatidylserine, vimentin/cardiolipin, protein S, protein C, annexin A2, annexin A5, and phospholipid antigens is discussed. Moreover, new technical approaches, including chemiluminescence, multiline dot assay, and thin layer chromatography (TLC) immunostaining, which utilize different supports for detection of aPL, have been developed. A special focus has been dedicated on “seronegative” APS, that is, those patients with a clinical profile suggestive of APS (thromboses, recurrent miscarriages, or foetal loss), who are persistently negative for the routinely used aPL. Recent findings suggest that, in sera from patients with SN-APS, antibodies may be detected using “new” antigenic targets (mainly vimentin/cardiolipin) or methodological approaches different from traditional techniques (TLC immunostaining). Thus, APS represents a mosaic, in which antibodies against different antigenic targets may be detected thanks to the continuously evolving new technologies. PMID:25874238

  3. A FRET-based high throughput screening assay to identify inhibitors of anthrax protective antigen binding to capillary morphogenesis gene 2 protein.

    Directory of Open Access Journals (Sweden)

    Michael S Rogers

    Full Text Available Anti-angiogenic therapies are effective for the treatment of cancer, a variety of ocular diseases, and have potential benefits in cardiovascular disease, arthritis, and psoriasis. We have previously shown that anthrax protective antigen (PA, a non-pathogenic component of anthrax toxin, is an inhibitor of angiogenesis, apparently as a result of interaction with the cell surface receptors capillary morphogenesis gene 2 (CMG2 protein and tumor endothelial marker 8 (TEM8. Hence, molecules that bind the anthrax toxin receptors may be effective to slow or halt pathological vascular growth. Here we describe development and testing of an effective homogeneous steady-state fluorescence resonance energy transfer (FRET high throughput screening assay designed to identify molecules that inhibit binding of PA to CMG2. Molecules identified in the screen can serve as potential lead compounds for the development of anti-angiogenic and anti-anthrax therapies. The assay to screen for inhibitors of this protein-protein interaction is sensitive and robust, with observed Z' values as high as 0.92. Preliminary screens conducted with a library of known bioactive compounds identified tannic acid and cisplatin as inhibitors of the PA-CMG2 interaction. We have confirmed that tannic acid both binds CMG2 and has anti-endothelial properties. In contrast, cisplatin appears to inhibit PA-CMG2 interaction by binding both PA and CMG2, and observed cisplatin anti-angiogenic effects are not mediated by interaction with CMG2. This work represents the first reported high throughput screening assay targeting CMG2 to identify possible inhibitors of both angiogenesis and anthrax intoxication.

  4. Antigen specific T-cell responses against tumor antigens are controlled by regulatory T cells in patients with prostate cancer.

    Science.gov (United States)

    Hadaschik, Boris; Su, Yun; Huter, Eva; Ge, Yingzi; Hohenfellner, Markus; Beckhove, Philipp

    2012-04-01

    Immunotherapy is a promising approach in an effort to control castration resistant prostate cancer. We characterized tumor antigen reactive T cells in patients with prostate cancer and analyzed the suppression of antitumor responses by regulatory T cells. Peripheral blood samples were collected from 57 patients with histologically confirmed prostate cancer, 8 patients with benign prostatic hyperplasia and 16 healthy donors. Peripheral blood mononuclear cells were isolated and antigen specific interferon-γ secretion of isolated T cells was analyzed by enzyme-linked immunospot assay. T cells were functionally characterized and T-cell responses before and after regulatory T-cell depletion were compared. As test tumor antigens, a panel of 11 long synthetic peptides derived from a total of 8 tumor antigens was used, including prostate specific antigen and prostatic acid phosphatase. In patients with prostate cancer we noted a 74.5% effector T-cell response rate compared with only 25% in patients with benign prostatic hyperplasia and 31% in healthy donors. In most patients 2 or 3 tumor antigens were recognized. Comparing various disease stages there was a clear increase in the immune response against prostate specific antigens from intermediate to high risk tumors and castration resistant disease. Regulatory T-cell depletion led to a significant boost in effector T-cell responses against prostate specific antigen and prostatic acid phosphatase. Tumor specific effector T cells were detected in most patients with prostate cancer, especially those with castration resistant prostate cancer. Since effector T-cell responses against prostate specific antigens strongly increased after regulatory T-cell depletion, our results indicate that immunotherapy efficacy could be enhanced by decreasing regulatory T cells. Copyright © 2012 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Diagnosis of Coxiella burnetii infection: comparison of a whole blood interferon-gamma production assay and a Coxiella ELISPOT.

    Directory of Open Access Journals (Sweden)

    Teske Schoffelen

    Full Text Available Diagnosis of ongoing or past infection with Coxiella burnetii, the causative agent of Q fever, relies heavily on serology: the measurement of C. burnetii-specific antibodies, reflecting the host's humoral immune response. However, cell-mediated immune responses play an important, probably even more relevant, role in infections caused by the intracellular C. burnetii bacterium. Recent studies have investigated interferon-gamma (IFN-γ based assays, including a whole-blood IFN-γ production assay and a Coxiella enzyme-linked immunospot (Coxiella ELISPOT, as potential diagnostic tools for Q fever diagnosis. Both are in-house developed assays using stimulating antigens of different origin. The main objective of this study was to compare the test performance of the IFN-γ production assay and the Coxiella ELISPOT for detecting a cellular immune response to C. burnetii in Q fever patients, and to assess the correlation between both assays. To that end, both tests were performed in a well-defined patient group of chronic Q fever patients (n = 16 and a group of healthy seronegative individuals (n = 17. Among patients, both the Coxiella ELISPOT and the IFN-γ production assay detected positive response in 14/16. Among controls, none were positive in the Coxiella ELISPOT, whereas the IFN-γ production assay detected positive results in 1/17 and 3/17, when using Henzerling and Nine Mile as stimulating antigens, respectively. These results suggest the Coxiella ELISPOT has a somewhat higher specificity than the IFN-γ production assay when Nine Mile is used as antigen stimulus. The assays showed moderate correlation: the Spearman correlation coefficient r ranged between 0.37-0.60, depending on the antigens used. Further investigation of the diagnostic potential for C. burnetii infection of both assays is warranted.

  6. Serodiagnosis of sporotrichosis infection in cats by enzyme-linked immunosorbent assay using a specific antigen, SsCBF, and crude exoantigens.

    Science.gov (United States)

    Fernandes, Geisa Ferreira; Lopes-Bezerra, Leila Maria; Bernardes-Engemann, Andréa Reis; Schubach, Tânia Maria Pacheco; Dias, Maria Adelaide Galvão; Pereira, Sandro Antonio; de Camargo, Zoilo Pires

    2011-01-27

    The main objective of this study is to standardize an ELISA for the diagnosis of feline sporotrichosis. Sporothrix schenckii is the etiological agent of human and animal sporotrichosis. Cats may act as reservoirs for S. schenckii and can transmit the infection to humans by a bite or scratch. There are few methods for the serological diagnosis of fungal diseases in animals. In this paper, an ELISA test for the diagnosis of cat sporotrichosis is proposed, which detects S. schenckii-specific antibodies in feline sera. Two different kinds of antigens were used: "SsCBF", a specific molecule from S. schenckii that consists of a Con A-binding fraction derived from a peptido-rhamnomannan component of the cell wall, and a S. schenckii crude exoantigen preparation. The ELISA was developed, optimized, and evaluated using sera from 30 cats with proven sporotrichosis (by culture isolation); 22 sera from healthy feral cats from a zoonosis center were used as negative controls. SsCBF showed 90% sensitivity and 96% specificity in ELISA; while crude exoantigens demonstrated 96% sensitivity and 98% specificity. The ELISA assay described here would be a valuable screening tool for the detection of specific S. schenckii antibodies in cats with sporotrichosis. The assay is inexpensive, quick to perform, easy to interpret, and permits the diagnosis of feline sporotrichosis. Copyright © 2010 Elsevier B.V. All rights reserved.

  7. A highly sensitive solid-phase radioimmunoassay for the assay of Plasmodium falciparum antigens and antibodies

    International Nuclear Information System (INIS)

    Avraham, H.; Golenser, J.; Gazitt, Y.; Spira, D.T.; Sulitzeanu, D.

    1982-01-01

    A highly sensitive radioimmunoassay for detection of P. falciparum antibodies and antigens is described. A partially purified P. falciparum antigen preparation is obtained from in vitro cultured parasites enriched after gelatin sedimentation by sonicating the infected red blood cells and precipitating the proteins with 50% saturated ammonium sulfate. The precipitate is dissolved in buffer, ultracentrifuged and used to coat wells of microtiter plates. Anti-P. falciparum antibodies are detected by incubating antiserum dilutions in the coated wells and detecting the bound IgG with radioiodinated staphylococcal protein A. P. falciparum antigens are detected by their ability to inhibit binding of antibodies to the coated wells. Sera of individuals with a history of P. falciparum infection contain antibodies detectable at a dilution of 1:75,000. P. falciparum RBC infected in vitro can be detected at levels of parasitemia of the order of 1 parasite or less per 10 6 RBC. (Auth.)

  8. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    International Nuclear Information System (INIS)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo

    2011-01-01

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R 2= 0.838, P 2= 0.067, P=0.316 by IRMA, and R 2= 0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients

  9. Dot-blot immunoassay of Fasciola gigantica infection using 27 kDa and adult worm regurge antigens in Egyptian patients.

    Science.gov (United States)

    Kamel, Hanan H; Saad, Ghada A; Sarhan, Rania M

    2013-04-01

    The purpose of the present study was to evaluate the potential role of the 27-Kilodalton (KDa) antigen versus Fasciola gigantica adult worm regurge antigens in a DOT-Blot assay and to assess this assay as a practical tool for diagnosis fascioliasis in Egyptian patients. Fasciola gigantica antigen of an approximate molecular mass 27-(KDa) was obtained from adult worms by a simple elution SDS-PAGE. A Dot-Blot was developed comparatively to adult worm regurge antigens for the detection of specific antibodies from patients infected with F. gigantica in Egypt. Control sera were obtained from patients with other parasitic infections and healthy volunteers to assess the test and compare between the antigens. The sensitivity, specificity, positive and negative predictive values of Dot-Blot using the adult worm regurge were 80%, 90%, 94.1%, and 69.2% respectively, while those using 27-KDa were 100% which confirms the diagnostic potential of this antigen. All patients infected with Fasciola were positive, with cross reactivity reported with Schistosoma mansoni serum samples. This 27-KDa Dot-Blot assay showed to be a promising test which can be used for serodiagnosis of fascioliasis in Egyptian patients especially, those presenting with hepatic disease. It is specific, sensitive and easy to perform method for the rapid diagnosis particularly when more complex laboratory tests are unavailable.

  10. Solid phase radioimmunoassays using labelled antibodies: a conceptual framework for designing assays

    International Nuclear Information System (INIS)

    Kalmakoff, J.; Parkinson, A.J.; Crawford, A.M.; Williams, B.R.G.

    1977-01-01

    A simple theoretical model for the antigen-antibody reaction is presented and used to evaluate the optimum conditions for designing solid phase radioimmunoassays (RIA) using labelled antibodies. Both theoretical and experimental data are presented, using a wide variety of antigens and their corresponding antibodies. The types of RIA described include the direct, the indirect, the direct sandwich assays for detecting either antigen or antibody. The experimental results confirm in a semiquantitative manner that the greatest sensitivity of the RIA is achieved when the smallest amount of labelled antibody is used, that whenever possible the antigen/antibody ratio should be greater than unity(>1), and that the formation of the antigen-antibody complex is dependent on the mass action effect

  11. High throughput production of mouse monoclonal antibodies using antigen microarrays

    DEFF Research Database (Denmark)

    De Masi, Federico; Chiarella, P.; Wilhelm, H.

    2005-01-01

    Recent advances in proteomics research underscore the increasing need for high-affinity monoclonal antibodies, which are still generated with lengthy, low-throughput antibody production techniques. Here we present a semi-automated, high-throughput method of hybridoma generation and identification....... Monoclonal antibodies were raised to different targets in single batch runs of 6-10 wk using multiplexed immunisations, automated fusion and cell-culture, and a novel antigen-coated microarray-screening assay. In a large-scale experiment, where eight mice were immunized with ten antigens each, we generated...

  12. Pelacakan Secara Imunohistokimiawi Antigen Virus pada Ayam yang Diinfeksi dengan Virus Penyakit Tetelo (IMMUNOHISTOCHEMICAL DETECTION OF VIRAL ANTIGEN IN TISSUE OF CHICKENS EXPERIMENTALLY INFECTED WITH NEWCASTLE DISEASE VIRUS

    Directory of Open Access Journals (Sweden)

    Anak Agung Ayu Mirah Adi

    2013-07-01

    Full Text Available In order to study the distribution of Newcastle disease virus (NDV following infection, chickenswere experimentally infected with visceretropic velogenic NDV isolate. Monoclonal antibodies (mAbsagainst the NDV LaSota vaccine strain were then produced to detect viral antigen in the infectedorgans. The mAbs were firstly tested for their specificity by enzyme linked immunosorbent assay(ELISA using NDV and normal allantoic fluids as antigens. Eight mAbs specific against NDVwere isolated and two mAbs were used for immunodetection of NDV antigen in chicken’s tissues.By immunohistochemistry labeled streptavidin-biotin (LSAB staining NDV–antigen was detectedin paraffin embedded tissues of NDV-infected chickens. NDV antigen was not detected in noninfected chickens. In the infected chickens, high intensity of NDV antigen was detected in thelymphoid tissues, lung and intestine. The NDV antigen with a lesser intensity was detected in thebrain, trachea, liver and myocardium. This study shows that although viscerotropic velogenicNDV isolate can infect almost all organs, the main target of infection are lung, intestine andlymphoids tissues

  13. Seroprevalence of Cryptosporidium parvum infection of dairy cows in three northern provinces of Thailand determined by enzyme-linked immunosorbent assay using recombinant antigen CpP23.

    Science.gov (United States)

    Inpankaew, T; Jittapalapong, S; Phasuk, J; Pinyopanuwut, N; Chimnoi, W; Kengradomkit, C; Sunanta, C; Zhang, G; Aboge, G O; Nishikawa, Y; Igarashi, I; Xuan, X

    2009-06-01

    Cryptosporidium parvum is the most frequent parasitic agent that causes diarrhoea in AIDS patients in Thailand. Cryptosporidiosis outbreaks in humans may be attributed to contamination of their drinking water from infected dairy pastures. A 23-kDa glycoprotein of C. parvum (CpP23) is a sporozoite surface protein that is geographically conserved among C. parvum isolates. This glycoprotein is a potentially useful candidate antigen for the diagnosis of cryptosporidiosis by enzyme-linked immunosorbent assay. Therefore, we investigated the seroprevalence of C. parvum infection in dairy cows in northern Thailand using an ELISA based on recombinant CpP23 antigen. Sera were randomly collected from 642 dairy cows of 42 small-holder farmers, which had the top three highest number of the dairy cows' population in Northern Thailand, that included Chiang Mai, Chiang Rai and Lumpang provinces. The overall seroprevalence of the infection was 4.4%, and the seropositive rates for the three provinces were 3.3% in Chiang Mai, 5.1% in Chiang Rai and 3% in Lumpang. These results suggest that cattle could play a role in zoonotic cryptosporidiosis in Thailand.

  14. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    International Nuclear Information System (INIS)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M.

    1982-01-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys. (Auth.)

  15. Antibodies to poliovirus detected by immunoradiometric assay with a monoclonal antibody

    Energy Technology Data Exchange (ETDEWEB)

    Spitz, M.; Fossati, C.A.; Schild, G.C.; Spitz, L.; Brasher, M. (National Inst. for Biological Standards and Control, London (UK))

    1982-10-01

    An immunoradiometric assay (IRMA) for the assay of antibodies to poliovirus antigens is described. Dilutions of the test sera or whole (finger prick) blood samples were incubated with the poliovirus antigen bound to a solid phase and the specific antibody was detected by the addition of a mouse anti-human IgG monoclonal antibody (McAb), which was itself revealed by iodinated sheep IgG antimouse F(ab). The authors have shown that this technique is suitable for the estimation of IgG anti-poliovirus antibodies induced in children following polio vaccine. The present study shows that SPRIA provides a simple and inexpensive method for serological studies with poliovirus particularly for use in large-scale surveys.

  16. A Lateral Flow Protein Microarray for Rapid and Sensitive Antibody Assays

    Directory of Open Access Journals (Sweden)

    Helene Andersson-Svahn

    2011-11-01

    Full Text Available Protein microarrays are useful tools for highly multiplexed determination of presence or levels of clinically relevant biomarkers in human tissues and biofluids. However, such tools have thus far been restricted to laboratory environments. Here, we present a novel 384-plexed easy to use lateral flow protein microarray device capable of sensitive (< 30 ng/mL determination of antigen-specific antibodies in ten minutes of total assay time. Results were developed with gold nanobeads and could be recorded by a cell-phone camera or table top scanner. Excellent accuracy with an area under curve (AUC of 98% was achieved in comparison with an established glass microarray assay for 26 antigen-specific antibodies. We propose that the presented framework could find use in convenient and cost-efficient quality control of antibody production, as well as in providing a platform for multiplexed affinity-based assays in low-resource or mobile settings.

  17. Recombinant antigen-based immuno-slot blot method for serodiagnosis of syphilis

    Directory of Open Access Journals (Sweden)

    N.S. Sato

    2004-07-01

    Full Text Available Three recombinant antigens of Treponema pallidum Nichols strain were fused with GST, cloned and expressed in Escherichia coli, resulting in high levels of GST-rTp47 and GST-rTp17 expression, and supplementation with arginine tRNA for the AGR codon was needed to obtain GST-rTp15 overexpression. Purified fusion protein yields were 1.9, 1.7 and 5.3 mg/l of cell culture for GST-rTp47, GST-rTp17 and GST-rTp15, respectively. The identities of the antigens obtained were confirmed by automated DNA sequencing using ABI Prism 310 and peptide mapping by Finningan LC/MS. These recombinant antigens were evaluated by immuno-slot blot techniques applied to 137 serum samples from patients with a clinical and laboratory diagnosis of syphilis (61 samples, from healthy blood donors (50 samples, individuals with sexually transmitted disease other than syphilis (3 samples, and from individuals with other spirochetal diseases such as Lyme disease (20 samples and leptospirosis (3 samples. The assay had sensitivity of 95.1% (95% CI, 86.1 to 98.7% and a specificity of 94.7% (95% CI, 87.0 to 98.7%; a stronger reactivity was observed with fraction rTp17. The immunoreactivity results showed that fusion recombinant antigens based-immuno-slot blot techniques are suitable for use in diagnostic assays for syphilis.

  18. Relationship between the radioisotopic footpad assay and other immunological assays in tumor bearing rats

    International Nuclear Information System (INIS)

    Mizushima, Yutaka; Takeichi, Noritoshi; Minami, Akio; Kasai, Masaharu; Itaya, Toshiyuki

    1981-01-01

    KMT-17, a fibrosarcoma induced by 3-methylcholanthrene in a WKA rat, is a sensitive tumor to various kinds of immunological assays and is a suitable model tumor for the study of the immune status in tumor bearing hosts. The antitumor immune response of KMT-17 bearing rats was studied by a radioisotopic footpad assay (FPA) in comparison with other in vivo and in vitro assays. Delayed hypersensitivity to tumor antigens measured by the FPA was observed from the 8th day after transplantation of KMT-17 cells, reached a peak on the 12 - 15th day, and then declined in the late stage on the 17th day. The kinetics of the FPA correlated well with those of an in vivo Winn assay and of an in vitro lymphocyte cytotoxicity assay ( 51 Cr-release assay). The appearance of an antitumor antibody detected by a complement dependent cytotoxicity test also correlated well with the kinetics of the FPA. A growth inhibition assay (GIA) for non-specific cell-mediated immunity also showed similar kinetics to that of the FPA. The delayed hypersensitivity footpad reaction to tumor cell extracts measured by this FPA was tumor-specific. These results suggest that the FPA is a simple and reliable in vivo assay for evaluating antitumor immunity in tumor bearing hosts. (author)

  19. Profiling Humoral Immune Responses to Clostridium difficile-Specific Antigens by Protein Microarray Analysis.

    Science.gov (United States)

    Negm, Ola H; Hamed, Mohamed R; Dilnot, Elizabeth M; Shone, Clifford C; Marszalowska, Izabela; Lynch, Mark; Loscher, Christine E; Edwards, Laura J; Tighe, Patrick J; Wilcox, Mark H; Monaghan, Tanya M

    2015-09-01

    Clostridium difficile is an anaerobic, Gram-positive, and spore-forming bacterium that is the leading worldwide infective cause of hospital-acquired and antibiotic-associated diarrhea. Several studies have reported associations between humoral immunity and the clinical course of C. difficile infection (CDI). Host humoral immune responses are determined using conventional enzyme-linked immunosorbent assay (ELISA) techniques. Herein, we report the first use of a novel protein microarray assay to determine systemic IgG antibody responses against a panel of highly purified C. difficile-specific antigens, including native toxins A and B (TcdA and TcdB, respectively), recombinant fragments of toxins A and B (TxA4 and TxB4, respectively), ribotype-specific surface layer proteins (SLPs; 001, 002, 027), and control proteins (tetanus toxoid and Candida albicans). Microarrays were probed with sera from a total of 327 individuals with CDI, cystic fibrosis without diarrhea, and healthy controls. For all antigens, precision profiles demonstrated ELISA in the quantification of antitoxin A and antitoxin B IgG. These results indicate that microarray is a suitable assay for defining humoral immune responses to C. difficile protein antigens and may have potential advantages in throughput, convenience, and cost. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  20. Antigens of worms and eggs showed a differentiated detection of specific IgG according to the time of Schistosoma mansoni infection in mice

    Directory of Open Access Journals (Sweden)

    Rafaella Fortini Queiroz Grenfell

    2012-08-01

    Full Text Available INTRODUCTION: The correlation between the immunological assay and the antibody titer can offer a tool for the experimental analysis of different phases of the disease. METHODS: Two simple immunological assays for Schistosoma mansoni in mice sera samples based on specific IgG detection for worms soluble antigens and eggs soluble antigens were standardized and evaluated in our laboratory. Fifty mice were used in negative and positive groups and the results obtained by enzyme-linked immunosorbent assays (ELISA assays were compared with the number of worms counted and the IgG titers at different times of infection. RESULTS: Data showed that ELISA using adult worm antigens (ELISA-SWAP presented a satisfactory correlation between the absorbance value of IgG titers and the individual number of worms counted after perfusion technique (R²=0.62. In addition, ELISA-SWAP differentially detected positive samples with 30 and 60 days post infection (p=0.011 and 0.003, respectively, whereas ELISA using egg antigens (ELISA-SEA detected samples after 140 days (p=0.03. CONCLUSIONS: These data show that the use of different antigens in immunological methods can be used as potential tools for the analysis of the chronological evolution of S. mansoni infection in murine schistosomiasis. Correlations with human schistosomiasis are discussed.

  1. Augmentation of antigen-specific immune responses using DNA-fusogenic liposome vaccine

    International Nuclear Information System (INIS)

    Yoshikawa, Tomoaki; Imazu, Susumu; Gao Jianqing; Hayashi, Kazuyuki; Tsuda, Yasuhiro; Shimokawa, Mariko; Sugita, Toshiki; Niwa, Takako; Oda, Atushi; Akashi, Mitsuru; Tsutsumi, Yasuo; Mayumi, Tadanori; Nakagawa, Shinsaku

    2004-01-01

    In an attempt to enhance the immunological efficacy of genetic immunization, we investigated a new biological means for delivering antigen gene directly to the cytoplasm via membrane fusion. In this context, we investigated fusogenic liposome (FL) encapsulating DNA as a possible genetic immunization vehicle. RT-PCR analysis indicated that a FL could introduce and express encapsulating OVA gene efficiently and rapidly in vitro. Consistent with this observation, an in vitro assay showed that FL-mediated antigen-gene delivery can induce potent presentation of antigen via the MHC class I-dependent pathway. Accordingly, immunization with FL containing the OVA-gene induced potent OVA-specific Th1 and Th2 cytokine production. Additionally, OVA-specific CTL responses and antibody production were also observed in systemic compartments including the spleen, upon immunization with the OVA-gene encapsulating FL. These findings suggest that FL is an effective genetic immunization carrier system for the stimulation of antigen-specific immune responses against its encoding antigen

  2. Genetic diversity and antigenicity variation of Babesia bovis merozoite surface antigen-1 (MSA-1) in Thailand.

    Science.gov (United States)

    Tattiyapong, Muncharee; Sivakumar, Thillaiampalam; Takemae, Hitoshi; Simking, Pacharathon; Jittapalapong, Sathaporn; Igarashi, Ikuo; Yokoyama, Naoaki

    2016-07-01

    Babesia bovis, an intraerythrocytic protozoan parasite, causes severe clinical disease in cattle worldwide. The genetic diversity of parasite antigens often results in different immune profiles in infected animals, hindering efforts to develop immune control methodologies against the B. bovis infection. In this study, we analyzed the genetic diversity of the merozoite surface antigen-1 (msa-1) gene using 162 B. bovis-positive blood DNA samples sourced from cattle populations reared in different geographical regions of Thailand. The identity scores shared among 93 msa-1 gene sequences isolated by PCR amplification were 43.5-100%, and the similarity values among the translated amino acid sequences were 42.8-100%. Of 23 total clades detected in our phylogenetic analysis, Thai msa-1 gene sequences occurred in 18 clades; seven among them were composed of sequences exclusively from Thailand. To investigate differential antigenicity of isolated MSA-1 proteins, we expressed and purified eight recombinant MSA-1 (rMSA-1) proteins, including an rMSA-1 from B. bovis Texas (T2Bo) strain and seven rMSA-1 proteins based on the Thai msa-1 sequences. When these antigens were analyzed in a western blot assay, anti-T2Bo cattle serum strongly reacted with the rMSA-1 from T2Bo, as well as with three other rMSA-1 proteins that shared 54.9-68.4% sequence similarity with T2Bo MSA-1. In contrast, no or weak reactivity was observed for the remaining rMSA-1 proteins, which shared low sequence similarity (35.0-39.7%) with T2Bo MSA-1. While demonstrating the high genetic diversity of the B. bovis msa-1 gene in Thailand, the present findings suggest that the genetic diversity results in antigenicity variations among the MSA-1 antigens of B. bovis in Thailand. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Development of a radioimmunoassay for a high molecular mass tubular antigen in urine - its application for early detection of tubular damage

    International Nuclear Information System (INIS)

    Sachse, H.J.; Falkenberg, F.W.; Scherberich, J.E.; Stefanescu, T.; Fassbinder, W.; Mondorf, A.W.; Schoeppe, W.

    1981-01-01

    In order to isolate urinary kidney antigens, the gammaglobulin fraction of an antiserum against human kidney cortex plasma membranes was coupled to Sepharose 4B. By immunospecific affinity chromatography an antigen fraction was obtained from the urine of a patient suffering from severe kidney disease. After gel filtration, the main fraction, eluted with the exclusion volume of a Sephadex G-200 column and enriched 16000-fold, was labelled with 131 I and used in a radioimmunoassay system. Soluble kidney antigens, presumably of proximal tubular origin, could be detected and quantified by the assay system in urine samples of patients with various diseases. The samples did not need to be treated, either concentrated or dialyzed, before application. The results of the experiments show a correlation between antigen excretion and kidney damage. Rejection episodes in patients with kidney transplants could be recognized early by enhanced antigen excretion. Potentially nephrotoxic drugs caused antigen excretion as well. In normal, healthy subjects output of the antigen was very low. The assay system might be of value for monitoring renal diseases. (Auth.)

  4. Comparison of Simplexa universal direct PCR with cytotoxicity assay for diagnosis of Clostridium difficile infection: performance, cost, and correlation with disease.

    Science.gov (United States)

    Landry, Marie L; Ferguson, David; Topal, Jeffrey

    2014-01-01

    Simplexa Clostridium difficile universal direct PCR, a real-time PCR assay for the detection of the C. difficile toxin B (tcdB) gene using the 3M integrated cycler, was compared with a two-step algorithm which includes the C. Diff Chek-60 glutamate dehydrogenase (GDH) antigen assay followed by cytotoxin neutralization. Three hundred forty-two liquid or semisolid stools submitted for diagnostic C. difficile testing, 171 GDH antigen positive and 171 GDH antigen negative, were selected for the study. All samples were tested by the C. Diff Chek-60 GDH antigen assay, cytotoxin neutralization, and Simplexa direct PCR. Of 171 GDH-positive samples, 4 were excluded (from patients on therapy or from whom duplicate samples were obtained) and 88 were determined to be true positives for toxigenic C. difficile. Of the 88, 67 (76.1%) were positive by the two-step method and 86 (97.7%) were positive by PCR. Seventy-nine were positive by the GDH antigen assay only. Of 171 GDH antigen-negative samples, none were positive by PCR. One antigen-negative sample positive by the cytotoxin assay only was deemed a false positive based on chart review. Simplexa C. difficile universal direct PCR was significantly more sensitive for detecting toxigenic C. difficile bacteria than cytotoxin neutralization (P = 0.0002). However, most PCR-positive/cytotoxin-negative patients did not have clear C. difficile disease. The estimated cost avoidance provided by a more rapid molecular diagnosis was outweighed by the cost of isolating and treating PCR-positive/cytotoxin-negative patients. The costs, clinical consequences, and impact on nosocomial transmission of treating and/or isolating patients positive for toxigenic C. difficile by PCR but negative for in vivo toxin production merit further study.

  5. Development of a Novel, Ultra-rapid Biosensor for the Qualitative Detection of Hepatitis B Virus-associated Antigens and Anti-HBV, Based on “Membrane-engineered” Fibroblast Cells with Virus-Specific Antibodies and Antigens

    Directory of Open Access Journals (Sweden)

    Antonios Perdikaris

    2009-03-01

    Full Text Available A novel miniature cell biosensor detection system for the detection of Hepatis B virus (HBV-associated antigens and anti-HBV is described. The biosensor is based on “membrane-engineered” Vero fibroblast cells immobilized in an alginate matrix. The membrane-engineering process involved the electroinsertion of anti-HBV specific antibodies (anti-HBs, anti-HBe or antigens (HBsAg in the membranes of the Vero cells. The attachment of a homologous antigen to the electroinserted antibody (or, respectively, of the antibody to the electroinserted antigen triggered specific changes to the cell membrane potential that were measured by appropriate microelectrodes, according to the principle of the Bioelectric Recognition Assay (BERA. The sensor was used for screening 133 clinical blood serum samples according to a double-blind protocol. Considerably higher sensor responses were observed against HBV-positive samples, compared with responses against negative samples or samples positive for heterologous hepatitis viruses such as Hepatitis C (HCV virus. Detection of anti-HBs antibodies was made possible by using a biosensor based on immobilized Vero cells bearing the respective antigen (HBsAg. The observed response was rapid (45 sec and quite reproducible. Fluorescence microscopy observations showed that attachment of HBV particles to cells membrane-engineered with anti-HBs was associated with a decrease of [Ca2+]cyt. The perspectives for using the novel biosensor as a qualitative, rapid screening, high throughput assay for HBV antigens and anti-HBs in clinical samples is discussed.

  6. Radioimmunoassay for Epstein-Barr Virus (EBV)-associated Nuclear Antigen (EBNA). Binding of iodinated antibodies to antigen immobilized in polyacrylamide gel

    International Nuclear Information System (INIS)

    Dolken, G.; Klein, G.

    1977-01-01

    A solid-phase radioimmunoassay was developed for the EBV-associated nuclear antigen (EBNA). Total homogenates of EBV-DNA and EBNA positive or negative cells were polymerized in polyacrylamide gel and compared for their ability to bind 125 I-IgG prepared from anti-EBNA positive and anti-EBNA negative sera. EBNA specific binding was demonstrated and confirmed by serological and cellular specificity controls. The assay allows the quantitation of antigen or antibody even in the presence of detergents and is suitable for biochemical characterization of the antigen. Reciprocal blocking studies with extracts from different cell lines showed quantitative and qualitative differences. One part of the EBNA specificiti(es) present in the human Burkitt lymphoma derived lines RAJI, DAUDI and AW-RAMOS was lacking in B96-8, a marmoset line carrying EBV derived from a human infectious mononucleosis line. This result may reflect differences in the viral genomes derived from Burkitt lymphoma and infectious mononucleosis lines or differences in the host cells. (author)

  7. (ELISA) kit for diagnosis copro-antigens of Giardia lamblia

    African Journals Online (AJOL)

    STORAGESEVER

    2010-08-02

    Aug 2, 2010 ... methods based on antigen scanning of parasites such as enzyme linked immunosorbent assay (ELISA), ... samples. To design this method, a pure antibody against parasite as well as an antibody conjugated to a ..... school children in Santiago, Chile by capture ELISA for the detection of fecal Giardia ...

  8. Novel immunoradiometric assay of thyroglobulin in serum with use of monoclonal antibodies selected for lack of cross-reactivity with autoantibodies

    International Nuclear Information System (INIS)

    Piechaczyk, M.; Baldet, L.; Pau, B.; Bastide, J.M.

    1989-01-01

    A multisite immunoradiometric assay for measurement of serum thyroglobulin (Tg), designated Magnogel-IRMA-Tg, has been developed, involving magnetic microbeads (Magnogel). This assay is based on the use of five anti-Tg monoclonal antibodies (MAbs) directed against three antigenic regions on the Tg molecule that are not recognized by anti-Tg autoantibodies (aAbs). Four of these MAbs, directed against two antigenic domains, were coupled to the magnetic beads and were used to trap the serum antigen. Another MAb, directed against the third region, was iodinated and served as the labeled second antibody. The Magnogel-IRMA-Tg technique is reproducible, rapid, and sensitive (lower detection limit, 3 micrograms/L). The assay reliably measures serum Tg in the presence of anti-Tg aAbs

  9. Antigenic differences between bovine viral diarrhea viruses and HoBi virus: Possible impacts on diagnosis and control

    Science.gov (United States)

    Compare antigenic differences between HoBi virus and BVDV strains that might impact on diagnostics and control. Eighteen non-cytopathic isolates of pestiviruses including the 5 genotypic groups (BVDV1a-c, BVDV2, BDV) and HoBi virus, were tested using antigen capture enzyme-linked immunosorbent assay...

  10. Means for use in radioimmunodetection of an antigen-antibody reaction

    International Nuclear Information System (INIS)

    Reynolds, J.H.

    1983-01-01

    A unitized, solid phase kit for radioimmunoassay is described. All of the necessary assay reagents are incorporated in a single tube. Requiring only the addition of the patient's sample, all phases of the assay procedure are performed in this tube. Antibodies are bound to the tube surface, while labelled antigens are also present but unbound. Storage in the absence of air and water results in the stabilization of the reagents such that the system can be stored for long periods

  11. Designed ankyrin repeat proteins: a new approach to mimic complex antigens for diagnostic purposes?

    Directory of Open Access Journals (Sweden)

    Stefanie Hausammann

    Full Text Available Inhibitory antibodies directed against coagulation factor VIII (FVIII can be found in patients with acquired and congenital hemophilia A. Such FVIII-inhibiting antibodies are routinely detected by the functional Bethesda Assay. However, this assay has a low sensitivity and shows a high inter-laboratory variability. Another method to detect antibodies recognizing FVIII is ELISA, but this test does not allow the distinction between inhibitory and non-inhibitory antibodies. Therefore, we aimed at replacing the intricate antigen FVIII by Designed Ankyrin Repeat Proteins (DARPins mimicking the epitopes of FVIII inhibitors. As a model we used the well-described inhibitory human monoclonal anti-FVIII antibody, Bo2C11, for the selection on DARPin libraries. Two DARPins were selected binding to the antigen-binding site of Bo2C11, which mimic thus a functional epitope on FVIII. These DARPins inhibited the binding of the antibody to its antigen and restored FVIII activity as determined in the Bethesda assay. Furthermore, the specific DARPins were able to recognize the target antibody in human plasma and could therefore be used to test for the presence of Bo2C11-like antibodies in a large set of hemophilia A patients. These data suggest, that our approach might be used to isolate epitopes from different sets of anti-FVIII antibodies in order to develop an ELISA-based screening assay allowing the distinction of inhibitory and non-inhibitory anti-FVIII antibodies according to their antibody signatures.

  12. Antibody reaction of human anti-Toxoplasma gondii positive and negative sera with Neospora caninum antigens

    OpenAIRE

    Nam, Ho-Woo; Kang, Seung-Won; Choi, Won-Young

    1998-01-01

    Anti-Neospora caninum antibody was detected in anti-Toxoplasma gondii positive and negative human sera by ELISA, western blot and immunofluorescence assay (IFA). Twelve cases out of 172 (6.7%) Toxoplasma-positive sera cross-reacted with both T. gondii and N. caninum antigens, and one out of 110 Toxoplasma-negative sera reacted with N. caninum antigen by ELISA. By western blot, all 12 sera reacted with T. gondii antigens with various banding patterns but specifically at 30 kDa (SAG1) and 22 kD...

  13. Lymphocyte proliferation to mycobacterial antigens is detectable across a spectrum of HIV-associated tuberculosis

    Directory of Open Access Journals (Sweden)

    Bakari Muhammad

    2009-02-01

    Full Text Available Abstract Background Identifying novel TB diagnostics is a major public health priority. We explored the diagnostic characteristics of antimycobacterial lymphocyte proliferation assays (LPA in HIV-infected subjects with latent or active TB. Methods HIV-infected subjects with bacille Calmette Guérin (BCG scars and CD4 counts ≥ 200 cells/mm3 entering a TB booster vaccine trial in Tanzania had baseline in vivo and in vitro immune tests performed: tuberculin skin tests (TST, LPA and five day assays of interferon gamma (IFN-γ release. Assay antigens were early secreted antigenic target 6 (ESAT-6, antigen 85 (Ag85, and Mycobacterium tuberculosis whole cell lysate (WCL. Subjects were screened for active TB at enrollment by history, exam, sputum smear and culture. We compared antimycobacterial immune responses between subjects with and without latent or active TB at enrollment. Results Among 1885 subjects screened, 635 had latent TB and 13 had active TB. Subjects with latent TB were more likely than subjects without TB to have LPA responses to ESAT-6 (13.2% vs. 5.5%, P Conclusion Lymphoproliferative responses to mycobacteria are detectable during HIV-associated active TB, and are less sensitive but more specific than TST. Trial registration ClinicalTrials.gov Identifier NCT00052195.

  14. The antigenic property of the H5N1 avian influenza viruses isolated in central China

    Directory of Open Access Journals (Sweden)

    Zou Wei

    2012-08-01

    Full Text Available Abstract Background Three influenza pandemics outbroke in the last century accompanied the viral antigen shift and drift, resulting in the change of antigenic property and the low cross protective ability of the existed antibody to the newly emerged pandemic virus, and eventually the death of millions of people. The antigenic characterizations of the viruses isolated in central China in 2004 and 2006–2007 were investigated in the present study. Results Hemagglutinin inhibition assay and neutralization assay displayed differential antigenic characteristics of the viruses isolated in central China in two periods (2004 and 2006–2007. HA genes of the viruses mainly located in two branches in phylogeny analysis. 53 mutations of the deduced amino acids of the HA genes were divided into 4 patterns. Mutations in pattern 2 and 3 showed the main difference between viruses isolated in 2004 and 2006–2007. Meanwhile, most amino acids in pattern 2 and 3 located in the globular head of the HA protein, and some of the mutations evenly distributed at the epitope sites. Conclusions The study demonstrated that a major antigenic drift had occurred in the viruses isolated in central China. And monitoring the antigenic property should be the priority in preventing the potential pandemic of H5N1 avian influenza virus.

  15. Comparison of IgM Capture Enzyme- Linked Immunosorbent Assay (ELISA) using Inhouse method and commercially available MRL kit for serological confirmation of dengue infection

    International Nuclear Information System (INIS)

    Hapugoda, D.M.; De Silva R, Nilanthi; Abeywickreme, W.; Gunasena, Sunethra; Prithimala, L.D.; Jayawardene, S.L.G.J.; Kumari, Thamara

    2003-01-01

    Laboratory diagnosis of dengue infection is important for the management of the patients. In this study igM capture ELISA using an inhouse method and commercially available kit (MRL diagnostics,USA) was compared to detect diagnostic capability of Inhouse IgM ELISA for provision of diagnostic facilities to the public at an affordable cost. Eighty acute and convalescent serum samples were collected from serologically confirmed dengue patients. Serological confirmation of patients were performed by Haemagglutination Inhibition (HI) assay, gold standard assay for dengue on paired serum samples. All collected acute and convalescent sera were tested by IgM ELISA using the inhouse method and MRL kit. Antigen and conjugate for the inhouse IgM method were prepared in the laboratory. A cocktail of four dengue antigens containing 25 Antigen ELISA units of each type was prepared and used as the assay antigen. Conjugate was prepared using a serum sample with high dengue Anti flavi IgG antibody titre conjugated with Horseradish peroxidase. A prospective study of both IgM ELISA assays were performed using 113 acute sera collected from dengue suspected cases. Overall results showed that 46% and 52% acute sera collected from dengue confirmed patients were positive by inhouse ELISA assay and MRL kits respectively. In the prospective study done using acute sera collected from dengue suspected patients showed that 44% and 52% were positive by inhouse ELISA assay and MRL kits. There was no significant difference in positivity between these two assays. (P=0.18). Inhouse IgM ELISA can be used for provision of laboratory diagnosis of dengue virus infection more than 5 days. The assay is 10 times less costly than using MRL kits as assay antigen and conjugate can be prepared easily in the laboratory

  16. Pooled protein immunization for identification of cell surface antigens in Streptococcus sanguinis.

    Directory of Open Access Journals (Sweden)

    Xiuchun Ge

    2010-07-01

    Full Text Available Available bacterial genomes provide opportunities for screening vaccines by reverse vaccinology. Efficient identification of surface antigens is required to reduce time and animal cost in this technology. We developed an approach to identify surface antigens rapidly in Streptococcus sanguinis, a common infective endocarditis causative species.We applied bioinformatics for antigen prediction and pooled antigens for immunization. Forty-seven surface-exposed proteins including 28 lipoproteins and 19 cell wall-anchored proteins were chosen based on computer algorithms and comparative genomic analyses. Eight proteins among these candidates and 2 other proteins were pooled together to immunize rabbits. The antiserum reacted strongly with each protein and with S. sanguinis whole cells. Affinity chromatography was used to purify the antibodies to 9 of the antigen pool components. Competitive ELISA and FACS results indicated that these 9 proteins were exposed on S. sanguinis cell surfaces. The purified antibodies had demonstrable opsonic activity.The results indicate that immunization with pooled proteins, in combination with affinity purification, and comprehensive immunological assays may facilitate cell surface antigen identification to combat infectious diseases.

  17. Pooled protein immunization for identification of cell surface antigens in Streptococcus sanguinis.

    Science.gov (United States)

    Ge, Xiuchun; Kitten, Todd; Munro, Cindy L; Conrad, Daniel H; Xu, Ping

    2010-07-26

    Available bacterial genomes provide opportunities for screening vaccines by reverse vaccinology. Efficient identification of surface antigens is required to reduce time and animal cost in this technology. We developed an approach to identify surface antigens rapidly in Streptococcus sanguinis, a common infective endocarditis causative species. We applied bioinformatics for antigen prediction and pooled antigens for immunization. Forty-seven surface-exposed proteins including 28 lipoproteins and 19 cell wall-anchored proteins were chosen based on computer algorithms and comparative genomic analyses. Eight proteins among these candidates and 2 other proteins were pooled together to immunize rabbits. The antiserum reacted strongly with each protein and with S. sanguinis whole cells. Affinity chromatography was used to purify the antibodies to 9 of the antigen pool components. Competitive ELISA and FACS results indicated that these 9 proteins were exposed on S. sanguinis cell surfaces. The purified antibodies had demonstrable opsonic activity. The results indicate that immunization with pooled proteins, in combination with affinity purification, and comprehensive immunological assays may facilitate cell surface antigen identification to combat infectious diseases.

  18. Mutational analysis of polyomavirus small-T-antigen functions in productive infection and in transformation.

    Science.gov (United States)

    Martens, I; Nilsson, S A; Linder, S; Magnusson, G

    1989-05-01

    The function of polyomavirus small T antigen in productive infection and in transformation was studied. Transfection of permissive mouse cells with mixtures of mutants that express only one type of T antigen showed that small T antigen increased large-T-antigen-dependent viral DNA synthesis approximately 10-fold. Under the same conditions, small T antigen was also essential for the formation of infectious virus particles. To analyze these activities of small T antigen, mutants producing protein with single amino acid replacements were constructed. Two mutants, bc1073 and bc1075, were characterized. Although both mutations led to the substitution of amino acid residues of more than one T antigen, the phenotype of both mutants was associated with alterations of the small T antigen. Both mutant proteins had lost their activity in the maturation of infectious virus particles. The bc1075 but not the bc1073 small T antigen had also lost its ability to stimulate viral DNA synthesis in mouse 3T6 cells. Finally, both mutants retained a third activity of small T antigen: to confer on rat cells also expressing middle T antigen the ability to grow efficiently in semisolid medium. The phenotypes of the mutants in these three assays suggest that small T antigen has at least three separate functions.

  19. Comparison between an immunochromatographic test with an amplified ELISA for detecting e antigen and anti-e antigen antibodies in chronic Hepatitis B

    International Nuclear Information System (INIS)

    Mainet Gonzalez, Damian; Palenzuela Gardon, Daniel O; Aguilar Rubido; Julio C

    2009-01-01

    The disappearance of the e antigen and the appearance of anti-e antigen antibodies are two biomarkers that indicate favorable prognosis in Hepatitis B. In this study the Advanced QualityTM immunochromatographic test for detecting those biomarkers was compared to the Vidas semi-quantitative ELISA test. Our hypothesis was that it is possible to use these biomarkers measured in a rapid and simple Advanced QualityTM immunochromatographic test for evaluating the therapeutic response in clinical trials with chronic hepatitis B patients. The two methods were done following the manufacturer's instructions. The sera were taken from 69 patients with chronic hepatitis B of the clinical trial of the CIGB 440 therapeutic candidate. The immunochromatographic test and ELISA for detecting e antigen and anti-e antigen antibodies presented from substantial to almost perfect agreement in the evaluation of the sera of chronic Hepatitis B patients in a clinical trial. The immunochromatographic test for detecting e antigen had a low positive average agreement and a high negative average agreement compared to the ELISA. Nevertheless, the immunochromatographic test for detecting anti-e antigen antibodies had a high negative and positive average agreement in comparison to the ELISA. The immunochromagraphic test for the e antigen had a lower positive average agreement compared to the ELISA and some patients infected with Hepatitis B virus could not be detected by the former assay. The immunochromatographic test for anti-e antigen antibodies showed a similar performance to that of ELISA and could therefore be used in clinical trials for chronic Hepatitis B in health institutions without the need of a highly qualified lab technician. (author)

  20. Diagnosis of hypersensitivity pneumonitis by measurement of antibodies against environmental antigens

    International Nuclear Information System (INIS)

    Dewair, M.

    1989-01-01

    Hypersensitivity pneumonitis (HP), an immunologically mediated chronic pulmonary disease, is the result of an inflammatory response of the lung initiated by the inhalation of environmental organic dusts. These organic dusts usually contain substances (antigens) capable of eliciting immune responses in humans. The symptoms of HP generally present as recurrent flu-like episodes which makes it difficult to establish the proper diagnosis. However, detection in patients' sera of high-titer antibodies against the environmental antigens could be of great help in identifying those materials causing the disease and which must be avoided. A highly specific and sensitive serodiagnostic test, a radioimmuno assay (RIA), was developed for measurement of antibodies against antigens relevant to Farmer's Lung Disease (FLD), a type of HP affecting farmers

  1. Antigenic Relationships among Human Pathogenic Orientia tsutsugamushi Isolates from Thailand.

    Directory of Open Access Journals (Sweden)

    Sarah L James

    2016-06-01

    Full Text Available Scrub typhus is a common cause of undiagnosed febrile illness in certain tropical regions, but can be easily treated with antibiotics. The causative agent, Orientia tsutsugamushi, is antigenically variable which complicates diagnosis and efforts towards vaccine development.This study aimed to dissect the antigenic and genetic relatedness of O. tsutsugamushi strains and investigate sero-diagnostic reactivities by titrating individual patient sera against their O. tsutsugamushi isolates (whole-cell antigen preparation, in homologous and heterologous serum-isolate pairs from the same endemic region in NE Thailand. The indirect immunofluorescence assay was used to titrate Orientia tsutsugamushi isolates and human sera, and a mathematical technique, antigenic cartography, was applied to these data to visualise the antigenic differences and cross-reactivity between strains and sera. No functional or antigen-specific analyses were performed. The antigenic variation found in clinical isolates was much less pronounced than the genetic differences found in the 56kDa type-specific antigen genes. The Karp-like sera were more broadly reactive than the Gilliam-like sera.Antigenic cartography worked well with scrub typhus indirect immunofluorescence titres. The data from humoral responses suggest that a Karp-like strain would provide broader antibody cross-reactivity than a Gilliam-like strain. Although previous exposure to O. tsutsugamushi could not be ruled out, scrub typhus patient serum antibody responses were characterised by strong homologous, but weak heterologous antibody titres, with little evidence for cross-reactivity by Gilliam-like sera, but a broader response from some Karp-like sera. This work highlights the importance of antigenic variation in O. tsutsugamushi diagnosis and determination of new serotypes.

  2. Equine infectious anemia virus-infected dendritic cells retain antigen presentation capability

    International Nuclear Information System (INIS)

    Rivera, Julie A.; McGuire, Travis C.

    2005-01-01

    To determine if equine monocyte-derived dendritic cells (DC) were susceptible to equine infectious anemia virus (EIAV) infection, ex vivo-generated DC were infected with virus in vitro. EIAV antigen was detected by immunofluorescence 3 days post-infection with maximum antigen being detected on day 4, whereas there was no antigen detected in DC incubated with the same amount of heat-inactivated EIAV. No cytolytic activity was observed after EIAV WSU5 infection of DC. These monocyte-derived DC were more effective than macrophages and B cells in stimulating allogenic T lymphocytes. Both infected macrophages and DC stimulated similar levels of memory CTL responses in mixtures of CD8+ and CD4+ cells as detected with 51 Cr-release assays indicating that EIAV infection of DC did not alter antigen presentation. However, EIAV-infected DC were more effective than infected macrophages when used to stimulate memory CTL in isolated CD8+ cells. The maintenance of antigen processing and presenting function by EIAV-infected DC in vitro suggests that this function is maintained during in vivo infection

  3. Comparative testing of six antigen-based malaria vaccine candidates directed toward merozoite-stage Plasmodium falciparum

    DEFF Research Database (Denmark)

    Arnot, David E; Cavanagh, David R; Remarque, Edmond J

    2008-01-01

    Immunogenicity testing of Plasmodium falciparum antigens being considered as malaria vaccine candidates was undertaken in rabbits. The antigens compared were recombinant baculovirus MSP-1(19) and five Pichia pastoris candidates, including two versions of MSP-1(19), AMA-1 (domains I and II), AMA-1......G concentrations. The two P. pastoris-produced MSP-1(19)-induced IgGs conferred the lowest growth inhibition. Comparative analysis of immunogenicity of vaccine antigens can be used to prioritize candidates before moving to expensive GMP production and clinical testing. The assays used have given discriminating...

  4. Detection of Hepatitis B Virus Antigens in Paraffin-embedded Liver Specimens from the Amazon Region, Brazil

    Directory of Open Access Journals (Sweden)

    Simonetti SRR

    2002-01-01

    Full Text Available Hepatic viscerotomy of paraffin-preserved old specimens, collected in the period from 1934 to 1967, were analyzed by immunohistochemical assays to detect hepatitis B, hepatitis D, dengue and yellow fever virus antigens. The material belongs to the Yellow Fever Collection, Department of Pathology, Instituto Oswaldo Cruz, Rio de Janeiro, Brazil and the cases were diagnosed at that time according to clinical aspects and histopathological findings reporting viral hepatitis, yellow fever, focal necrosis and hepatic atrophy. From the 79 specimens, 69 were collected at the Labrea Region and the other 10 in different other localities in the Amazon Region. The five micra thick histological slices were analyzed for the presence of hepatitis B surface antigen (HBsAg and hepatitis B core antigen (HBcAg by immunoperoxidase technique. An immunofluorescence assay was applied to the detection of hepatitis D, yellow fever and dengue virus antigens. Nine (11.4% histological samples were HBsAg reactive and 5 (6.3% were HBcAg reactive. The oldest reactive sample was from 1934. Viral antigens related to the other pathologies were not detected in this study. Our results confirm that the methodology described may be used to elucidate the aetiology of hepatitis diseases even after a long time of conservation of the specimens.

  5. Expression and the antigenicity of recombinant coat proteins of tungro viruses expressed in Escherichia coli.

    Science.gov (United States)

    Yee, Siew Fung; Chu, Chia Huay; Poili, Evenni; Sum, Magdline Sia Henry

    2017-02-01

    Rice tungro disease (RTD) is a recurring disease affecting rice farming especially in the South and Southeast Asia. The disease is commonly diagnosed by visual observation of the symptoms on diseased plants in paddy fields and by polymerase chain reaction (PCR). However, visual observation is unreliable and PCR can be costly. High-throughput as well as relatively cheap detection methods are important for RTD management for screening large number of samples. Due to this, detection by serological assays such as immunoblotting assays and enzyme-linked immunosorbent assay are preferred. However, these serological assays are limited by lack of continuous supply of antibodies as reagents due to the difficulty in preparing sufficient purified virions as antigens. This study aimed to generate and evaluate the reactivity of the recombinant coat proteins of Rice tungro bacilliform virus (RTBV) and Rice tungro spherical virus (RTSV) as alternative antigens to generate antibodies. The genes encoding the coat proteins of both viruses, RTBV (CP), and RTSV (CP1, CP2 and CP3) were cloned and expressed as recombinant fusion proteins in Escherichia coli. All of the recombinant fusion proteins, with the exception of the recombinant fusion protein of the CP2 of RTSV, were reactive against our in-house anti-tungro rabbit serum. In conclusion, our study showed the potential use of the recombinant fusion coat proteins of the tungro viruses as alternative antigens for production of antibodies for diagnostic purposes. Copyright © 2016 Elsevier B.V. All rights reserved.

  6. Optimization of Diagnostic Elisa - Based Tests for the Detection of Auto-Antibodies Against Tumor Antigens in Human Serum

    Directory of Open Access Journals (Sweden)

    Daria Štefatić

    2008-08-01

    Full Text Available Colorectal cancer is one of the most common cancer types worldwide and it continues to be a serious public health problem. Early detection and diagnosis are of great importance in cancer management. At present, diagnostic blood tests are based on the detection of tumor-associated markers such as carcinoembryonic antigen (CEA, the cancer antigen CA19-9 for gastrointestinal cancer, CA15-3 for breast cancer or CA125 for ovarian cancer. The lack of sensitivity and specificity of these markers prevents their general use in cancer screening of an average risk population. Therefore, new cancer biomarkers or better screening methods are necessary to improve the diagnostics of the disease. This study was directed to the optimization of a diagnostic, enzyme linked immunosorbent assay (ELISA based test to identify and validate new serum markers, such as extracellular Protein Kinase A (ecPKA and Nicotinamide A-Meth- yltransferase (NNMT. In this type of assay, the cancer antigens are quantified indirectly - by detecting the presence of auto-antibodies against tumor proteins in human serum. The result of the optimization and validation process was in the case of ecPKA a reproducible and stable assay. In case of NNMT the assay was probably not sensitive enough.

  7. Miniature silicon electronic biological assay chip and applications for rapid battlefield diagnostics

    Science.gov (United States)

    Cunningham, Brian T.; Regan, Robert A.; Clapp, Christopher; Hildebrant, Eric; Weinberg, Marc S.; Williams, John

    1999-07-01

    Assessing the medical condition of battlefield personnel requires the development of rapid, portable biological diagnostic assays for a wide variety of antigens and enzymes. Ideally, such an assay would be inexpensive, small, and require no added reagents while maintaining the sensitivity and accuracy of laboratory-based assays. In this work, a microelectromechanical (MEMS) based biological assay sensor is presented which is expected to meet the above requirements. The sensor is a thin silicon membrane resonator (SMR) which registers a decrease in resonant frequency when mass is adsorbed onto its surface. By coating the sensor surface with a monolayer of antibody, for example, we have detected the corresponding antigen with a detection resolution of 0.25 ng/ml in phosphate buffer solution. Micromachining techniques are being used to integrate many (64 elements on the first test chip) identical SMR sensors into a single silicon chip which would be capable of simultaneously performing a wide variety of biomedical assays. The sensors require only a small printed circuit board and 8V power supply to operate and provide a readout. The presentation will describe the operation of the SMR sensor, the fabrication of the sensor array, and initial test results using commercially available animal immunoglobulins in laboratory-prepared test solutions.

  8. Evaluation of immunoradiometric and ELISA versions of a microtitre plate assay for Bacillus anthracis spores

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, A P; Martin, K L; Cross, N L [Chemical Defence Experimental Establishment, Porton (UK); Drake, R G [Glasgow Univ. (UK). Inst. of Biochemistry

    1984-05-11

    Solid-phase indirectly-labelled antibody assays for Bacillus anthracis spores heat-fixed on polystyrene microtitre plates were compared as immunoradiometric assay (IRMA) and enzyme-linked immunosorbent assay (ELISA) versions. Signal-to-noise ratios were usually higher in the IRMA than in the ELISA performed under parallel conditions but replicates were more varied in the IRMA. The antigen detection threshold and resolution limit calculated after regression analysis were broadly comparable in the 2 types of assay.

  9. Enhanced target-specific signal detection using an Escherichia coli lysate in multiplex microbead immunoassays with E. coli-derived recombinant antigens.

    Science.gov (United States)

    Crestani, Sandra; Leitolis, Amanda; Lima, Lucianna Freitas Oliveira; Krieger, Marco A; Foti, Leonardo

    2016-08-01

    Diverse techniques have been developed to analyze antibody-mediated responses to infections. However, the most common tests, i.e., enzyme-linked immunosorbent assays, require separate reactions for each antigen and consequently necessitate large sample volumes. Luminex technology allows the detection of multiple antibodies in a single experiment, but nonspecific binding can impair the results. Therefore, we examined the use of Escherichia coli lysates to reduce nonspecific binding and improve the results of liquid microarrays based on Luminex technology. Anti-bacteria antibodies were detected in human serum samples, as evidenced by high median fluorescence intensity (MFI) in assays performed with paramagnetic microspheres coupled with E. coli lysates. Moreover, the addition of an E. coli lysate as a blocker reduced the nonspecific binding of antigens produced by E. coli in a concentration-dependent manner. Tris-HCl reduced MFI values in negative samples, but did not affect MFI for positive samples. For microspheres coupled with different antigens, an E. coli lysate blocker significantly improved the fluorescence signals from positive samples. The addition of Tris-HCl and the E. coli lysate induced antigen-specific differences in MFI. This combination of the E. coli lysate blocker and Tris-HCl yielded a statistically significant improvement in MFI in the assays for Chagas disease and hepatitis C virus samples. However, for the Treponema pallidum p47 antigen improvement in MFI was only observed for the preparation with the E. coli blocker at a concentration of 3%. In conclusion, the addition of an E. coli lysate and Tris-HCl to the microarray assay reduced the nonspecific binding of human anti-bacteria antibodies and, therefore, increased the specific MFI. Copyright © 2016 Elsevier B.V. All rights reserved.

  10. Vaxfectin enhances antigen specific antibody titers and maintains Th1 type immune responses to plasmid DNA immunization.

    Science.gov (United States)

    Reyes, L; Hartikka, J; Bozoukova, V; Sukhu, L; Nishioka, W; Singh, G; Ferrari, M; Enas, J; Wheeler, C J; Manthorpe, M; Wloch, M K

    2001-06-14

    Antigen specific immune responses were characterized after intramuscular immunization of BALB/c mice with 5 antigen encoding plasmid DNAs (pDNAs) complexed with Vaxfectin, a cationic lipid formulation. Vaxfectin increased IgG titers for all of the antigens with no effect on the CTL responses to the 2 antigens for which CTL assays were performed. Both antigen specific IgG1 and IgG2a were increased, although IgG2a remained greater than IgG1. Furthermore, Vaxfectin had no effect on IFN-gamma or IL-4 production by splenocytes re-stimulated with antigen, suggesting that the Th1 type responses typical of intramuscular pDNA immunization were not altered. Studies with IL-6 -/- mice suggest that the antibody enhancement is IL-6 dependent and results in a correlative increase in antigen specific antibody secreting cells.

  11. Quantitative Measurement of Serum Hepatitis B Surface Antigen Using an Immunoradiometric Assay in Chronic Hepatitis B

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyun Woo; Lee, Ho Young; Kim, Seog Gyun; Kim, Won; Jung, Wong Jin; Kang, Keon Wook; Chung, June Key; Lee, Myung Chul; Lee, Dong Soo [Seoul National Univ. Seoul (Korea, Republic of)

    2011-03-15

    Measurement of serum hepatitis B virus surface antigen (HBsAg) levels is important for the management of chronic hepatitis D patients in terms of monitoring response to antiviral therapy. This study aimed to evaluate the diagnostic performance of a new diagnostic kit, which quantitatively measures serum HBsAg level using an immunoradiometric assay (IRMA) based method. Measurements were compared with those obtained using a chemiluminescent microparticle immunoassay (CMIA) based method. The blood samples of 96 patients with chronic hepatitis B were used in this study. Copy numbers of serum hepatitis B virus (HBV) DNA were determined in 23 of these samples. The correlation between and the concordance of IRMA and CMIA results were determined using Pearson's correlation coefficients. P values of 0.05 were considered to be statistically significant throughout. Laboratory diagnoses based on CMIA. Furthermors, serum HBsAg levels by IRMA were found to be highly correlated with those determined by CMIA (correlation coefficient R{sup 2=}0.838, P<0.001). Serum HBsAg level and serum HBV DNA copies were found to be linearly related by both methods (R{sup 2=}0.067, P=0.316 by IRMA, and R{sup 2=}0.101, P=0.215 by CMIA). The diagnostic performance of the investigated IRMA method of determining HBsAg levels was found to be comparable with that of a CMIA based method in chronic hepatitis B patients.

  12. Application of recombinant hemagglutinin proteins as alternative antigen standards for pandemic influenza vaccines.

    Science.gov (United States)

    Choi, Yejin; Kwon, Seong Yi; Oh, Ho Jung; Shim, Sunbo; Chang, Seokkee; Chung, Hye Joo; Kim, Do Keun; Park, Younsang; Lee, Younghee

    2017-09-01

    The single radial immunodiffusion (SRID) assay, used to quantify hemagglutinin (HA) in influenza vaccines, requires reference reagents; however, because centralized production of reference reagents may slow the emergency deployment of vaccines, alternatives are needed. We investigated the production of HA proteins using recombinant DNA technology, rather than a traditional egg-based production process. The HA proteins were then used in an SRID assay as a reference antigen. We found that HA can be quantified in both egg-based and cell-based influenza vaccines when recombinant HAs (rHAs) are used as the reference antigen. Furthermore, we confirmed that rHAs obtained from strains with pandemic potential, such as H5N1, H7N3, H7N9, and H9N2 strains, can be utilized in the SRID assay. The rHA production process takes just one month, in contrast to the traditional process that takes three to four months. The use of rHAs may reduce the time required to produce reference reagents and facilitate timely introduction of vaccines during emergencies.

  13. Identification of Schistosoma mansoni candidate antigens for diagnosis of schistosomiasis

    Directory of Open Access Journals (Sweden)

    Gardenia Braz Figueiredo Carvalho

    2011-11-01

    Full Text Available The development of a more sensitive diagnostic test for schistosomiasis is needed to overcome the limitations of the use of stool examination in low endemic areas. Using parasite antigens in enzyme linked immunosorbent assay is a promising strategy, however a more rational selection of parasite antigens is necessary. In this study we performed in silico analysis of the Schistosoma mansoni genome, using SchistoDB database and bioinformatic tools for screening immunogenic antigens. Based on evidence of expression in all parasite life stage within the definitive host, extracellular or plasmatic membrane localization, low similarity to human and other helminthic proteins and presence of predicted B cell epitopes, six candidates were selected: a glycosylphosphatidylinositol-anchored 200 kDa protein, two putative cytochrome oxidase subunits, two expressed proteins and one hypothetical protein. The recognition in unidimensional and bidimensional Western blot of protein with similar molecular weight and isoelectric point to the selected antigens by sera from S. mansoni infected mice indicate a good correlation between these two approaches in selecting immunogenic proteins.

  14. Evaluation of a new set of recombinant antigens for the serological diagnosis of human and canine visceral leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Franklin B Magalhães

    Full Text Available Current strategies for the control of zoonotic visceral leishmaniasis (VL rely on its efficient diagnosis in both human and canine hosts. The most promising and cost effective approach is based on serologic assays with recombinant proteins. However, no single antigen has been found so far which can be effectively used to detect the disease in both dogs and humans. In previous works, we identified Leishmania infantum antigens with potential for the serodiagnosis of VL. Here, we aimed to expand the panel of the available antigens for VL diagnosis through another screening of a genomic expression library. Seven different protein-coding gene fragments were identified, five of which encoding proteins which have not been previously studied in Leishmania and rich in repetitive motifs. Poly-histidine tagged polypeptides were generated from six genes and evaluated for their potential for diagnosis of VL by ELISA (Enzyme Linked ImmunoSorbent Assay with sera from infected humans and dogs. None of those was valid for the detection of human VL (26-52% sensitivity although their performance was increased in the canine sera (48-91% sensitivity, with one polypeptide useful for the diagnosis of canine leishmaniasis. Next, we assayed a mixture of three antigens, found to be best for human or canine VL, among 13 identified through different screenings. This "Mix" resulted in similar levels of sensitivity for both human (84% and canine (88% sera. With improvements, this validates the use of multiple proteins, including antigens identified here, as components of a single system for the diagnosis of both forms of leishmaniasis.

  15. Multiantigen Print Immunoassay for Comparison of Diagnostic Antigens for Taenia solium Cysticercosis and Taeniasis▿

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N.; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E.; Garcia, Hector H.; Gilman, Robert H.; Tsang, Victor C. W.; Wilkins, Patricia P.

    2010-01-01

    One of the best-characterized tests for the diagnosis of neurocysticercosis is the enzyme-linked immunoelectrotransfer blot assay, developed at the CDC, which uses lentil lectin-purified glycoproteins (LLGPs) extracted from Taenia solium cysticerci. The purification of the LLGP antigens has been difficult to standardize, and the polyacrylamide gel system used for the immunoblot assay is not easily transferable to other laboratories. In this study, we developed a multiantigen printing immunoassay (MAPIA) to compare the performance of multiple recombinant Taenia solium proteins with the potential for the detection of cysticercosis and taeniasis. We prepared MAPIA strips using six cysticercosis and two taeniasis diagnostic proteins and compared the performance of the proteins with sera collected from defined cysticercosis and taeniasis cases. Of the six cysticercosis antigens, rT24H performed well in detecting cases with two or more viable cysts in the brain (sensitivity and specificity, 97% and 99.4%, respectively); the use of a combination of cysticercosis antigens did not improve the sensitivity of the test and decreased the specificity. None of the antigens could differentiate the different clinical presentations of cysticercosis. Both of the taeniasis antigens (rES33 and rES38) had the same sensitivity of 99.4% and specificities of 93.9% and 94.5%, respectively. Some cross-reactivity against rES33 and rES38 was found, especially with sera from cases infected with Schistosoma mansoni. We conclude that MAPIA is a simple and effective tool that may be used to compare antibody responses to different cysticercosis and taeniasis antigens and, in this case, may be useful for the rapid detection of T. solium cases. PMID:19906893

  16. Multiantigen print immunoassay for comparison of diagnostic antigens for Taenia solium cysticercosis and taeniasis.

    Science.gov (United States)

    Handali, Sukwan; Klarman, Molly; Gaspard, Amanda N; Noh, John; Lee, Yeuk-Mui; Rodriguez, Silvia; Gonzalez, Armando E; Garcia, Hector H; Gilman, Robert H; Tsang, Victor C W; Wilkins, Patricia P

    2010-01-01

    One of the best-characterized tests for the diagnosis of neurocysticercosis is the enzyme-linked immunoelectrotransfer blot assay, developed at the CDC, which uses lentil lectin-purified glycoproteins (LLGPs) extracted from Taenia solium cysticerci. The purification of the LLGP antigens has been difficult to standardize, and the polyacrylamide gel system used for the immunoblot assay is not easily transferable to other laboratories. In this study, we developed a multiantigen printing immunoassay (MAPIA) to compare the performance of multiple recombinant Taenia solium proteins with the potential for the detection of cysticercosis and taeniasis. We prepared MAPIA strips using six cysticercosis and two taeniasis diagnostic proteins and compared the performance of the proteins with sera collected from defined cysticercosis and taeniasis cases. Of the six cysticercosis antigens, rT24H performed well in detecting cases with two or more viable cysts in the brain (sensitivity and specificity, 97% and 99.4%, respectively); the use of a combination of cysticercosis antigens did not improve the sensitivity of the test and decreased the specificity. None of the antigens could differentiate the different clinical presentations of cysticercosis. Both of the taeniasis antigens (rES33 and rES38) had the same sensitivity of 99.4% and specificities of 93.9% and 94.5%, respectively. Some cross-reactivity against rES33 and rES38 was found, especially with sera from cases infected with Schistosoma mansoni. We conclude that MAPIA is a simple and effective tool that may be used to compare antibody responses to different cysticercosis and taeniasis antigens and, in this case, may be useful for the rapid detection of T. solium cases.

  17. Shedding of leukemia-associated P24 antigen by lymphoblastoid cell lines.

    Science.gov (United States)

    Komada, Y; Ochiai, H; Shimizu, K; Azuma, E; Kamiya, H; Sakurai, M

    1987-12-01

    We report the development of a unique enzyme-linked immunosorbent assay (ELISA) which makes possible the detection of leukemia-associated P24 antigen, utilizing its ability to bind the Ricinus communis agglutinin (RCA1) and a monoclonal antibody, SJ-9A4 simultaneously. Using the RCA1/SJ-9A4-ELISA, P24 antigen, as few as 50 X 10(3) cells from a common acute lymphoblastic leukemia (C-ALL) cell line could be detected. The presence of D-galactose gave complete and specific inhibition of P24 antigen binding to RCA1. Matched concentrations of D-glucose and D-sucrose had no effect on binding. The release of the P24 antigen into the culture medium by a C-ALL cell line maintained at 37 degrees C could be detected; however, no P24 antigen was present in the culture medium when the cells were maintained at 4 degrees C. Sequential analysis of the culture medium for soluble P24 antigen revealed that release of the P24 antigen associated with cell growth. Molecular sieve chromatography of concentrated culture medium indicated that shed P24 antigen was eluted in the macromolecule fraction. P24 antigen was detected in the cerebrospinal fluid (CSF) of four patients with P24 positive ALL at the time of relapse of the central nervous system (CNS) and was undetectable while in complete remission. The CSF from three patients with P24 negative ALL and three patients with aseptic meningitis had no detectable activity.

  18. Detection of avian influenza antigens in proximity fiber, droplet, and optical waveguide microfluidics

    Science.gov (United States)

    Yoon, Jeong-Yeol; Heinze, Brian C.; Gamboa, Jessica; You, David J.

    2009-05-01

    Virus antigens of avian influenza subtype H3N2 were detected on two different microfluidic platforms: microchannel and droplet. Latex immunoagglutination assays were performed using 920-nm highly carboxylated polystyrene beads that are conjugated with antibody to avian influenza virus. The bead suspension was merged with the solutions of avian influenza virus antigens in a Y-junction of a microchannel made by polydimethylsiloxane soft lithography. The resulting latex immunoagglutinations were measured with two optical fibers in proximity setup to detect 45° forward light scattering. Alternatively, 10 μL droplets of a bead suspension and an antigen solution were merged on a superhydrophobic surface (water contact angle = 155°), whose movement was guided by a metal wire, and 180° back light scattering is measured with a backscattering optical probe. Detection limits were 0.1 pg mL-1 for both microchannel with proximity fibers and droplet microfluidics, thanks to the use of micro-positioning stages to help generate reproducible optical signals. Additionally, optical waveguide was tested by constructing optical waveguide channels (filled with mineral oil) within a microfluidic device to detect the same light scattering. Detection limit was 0.1 ng mL-1 for an optical waveguide device, with a strong potential of improvement in the near future. The use of optical waveguide enabled smaller device setup, easier operation, smaller standard deviations and broader linear range of assay than proximity fiber microchannel and droplet microfluidics. Total assay time was less than 10 min.

  19. Identification of Low- and High-Impact Hemagglutinin Amino Acid Substitutions That Drive Antigenic Drift of Influenza A(H1N1 Viruses.

    Directory of Open Access Journals (Sweden)

    William T Harvey

    2016-04-01

    Full Text Available Determining phenotype from genetic data is a fundamental challenge. Identification of emerging antigenic variants among circulating influenza viruses is critical to the vaccine virus selection process, with vaccine effectiveness maximized when constituents are antigenically similar to circulating viruses. Hemagglutination inhibition (HI assay data are commonly used to assess influenza antigenicity. Here, sequence and 3-D structural information of hemagglutinin (HA glycoproteins were analyzed together with corresponding HI assay data for former seasonal influenza A(H1N1 virus isolates (1997-2009 and reference viruses. The models developed identify and quantify the impact of eighteen amino acid substitutions on the antigenicity of HA, two of which were responsible for major transitions in antigenic phenotype. We used reverse genetics to demonstrate the causal effect on antigenicity for a subset of these substitutions. Information on the impact of substitutions allowed us to predict antigenic phenotypes of emerging viruses directly from HA gene sequence data and accuracy was doubled by including all substitutions causing antigenic changes over a model incorporating only the substitutions with the largest impact. The ability to quantify the phenotypic impact of specific amino acid substitutions should help refine emerging techniques that predict the evolution of virus populations from one year to the next, leading to stronger theoretical foundations for selection of candidate vaccine viruses. These techniques have great potential to be extended to other antigenically variable pathogens.

  20. Identification of Low- and High-Impact Hemagglutinin Amino Acid Substitutions That Drive Antigenic Drift of Influenza A(H1N1) Viruses

    Science.gov (United States)

    Harvey, William T.; Benton, Donald J.; Gregory, Victoria; Hall, James P. J.; Daniels, Rodney S.; Bedford, Trevor; Haydon, Daniel T.; Hay, Alan J.; McCauley, John W.; Reeve, Richard

    2016-01-01

    Determining phenotype from genetic data is a fundamental challenge. Identification of emerging antigenic variants among circulating influenza viruses is critical to the vaccine virus selection process, with vaccine effectiveness maximized when constituents are antigenically similar to circulating viruses. Hemagglutination inhibition (HI) assay data are commonly used to assess influenza antigenicity. Here, sequence and 3-D structural information of hemagglutinin (HA) glycoproteins were analyzed together with corresponding HI assay data for former seasonal influenza A(H1N1) virus isolates (1997–2009) and reference viruses. The models developed identify and quantify the impact of eighteen amino acid substitutions on the antigenicity of HA, two of which were responsible for major transitions in antigenic phenotype. We used reverse genetics to demonstrate the causal effect on antigenicity for a subset of these substitutions. Information on the impact of substitutions allowed us to predict antigenic phenotypes of emerging viruses directly from HA gene sequence data and accuracy was doubled by including all substitutions causing antigenic changes over a model incorporating only the substitutions with the largest impact. The ability to quantify the phenotypic impact of specific amino acid substitutions should help refine emerging techniques that predict the evolution of virus populations from one year to the next, leading to stronger theoretical foundations for selection of candidate vaccine viruses. These techniques have great potential to be extended to other antigenically variable pathogens. PMID:27057693

  1. Assessment of a serum tumour marker for carcinoma of the pancreas: the carbohydrate antigen C.A. 19-9

    International Nuclear Information System (INIS)

    Vincent, D.; Venot, J.; Catanzano, G.; Clement, M.N.; Piquet, M.F.; Veyriras, E.; Beck, C.

    1985-01-01

    A radio-immunological assay with monoclonal antibodies was used to measure the C 19-9 antigen in 51 patients to determine its diagnostic value in cancer of the pancreas. The results show that the C 19-9 antigen is a good marker for carcinoma of the pancreas and that it can be commonly used [fr

  2. Use of an Interferon Gamma Release Assay (IGRA) to test T-cell responsiveness to soluble Leishmania infantum antigen in whole blood of dogs from endemic areas.

    Science.gov (United States)

    Zribi, Lilia; El-Goulli, Amel F; Ben-Abid, Meriem; Gharbi, Mohamed; Ben-Sghaier, Ines; Boufaden, Imed; Aoun, Karim; Bouratbine, Aïda

    2017-11-15

    Interferon-Gamma (IFN-γ) Release Assays (IGRAs) are easy tests that allow rapid screening of primed memory T-cells immunity in response to antigen. The aim of this study was to use IGRA to assess IFN-γ release in response to Soluble Leishmania infantum antigen (SLA) in whole blood of dogs living in endemic area of visceral leishmaniasis and to interpret IGRA results according to clinical examination, specific anti-Leishmania humoral response and presence of L. infantum DNA in blood. The study was carried out on 56 dogs living in greater Tunis area. Physical examination, quantitative serology and PCR on blood were used to characterize dogs' status in relation to Leishmania infection and disease. IGRA consisted on testing by ELISA for IFN-γ-secretion in whole blood after a 20-h challenge with SLA. PBS and Phytohemagglutinin (PHA) stimulations were used as controls. Four groups of dogs were characterized: 31 were negative by both serology and PCR, two had doubtful serology, 10 presented no to mild clinical signs but low antibodies levels and 13 were affected by Canine Leishmaniasis (CanL). In seronegative dogs, IGRA was little contributory in 4 puppies (age dogs (median age=72months, IQR: 45-84 months) that didn't respond to PHA stimulation, IGRA was negative in 19 and positive in three animals with lymph node enlargement. In dogs with doubtful serology, IGRA was positive in one dog and negative in the other. In infected dogs with no to mild clinical signs, one dog exhibited high level of IFN-γ in absence of antigenic stimulation and all the other were positive by IGRA. CanL dogs showed variable IGRA results. Negative IGRAs (n=4) were shown in animals with the highest parasitic burden whereas positive IGRAs (n=5) were shown in dogs with negative PCR or low parasitic load. The 4 remaining dogs either didn't respond to PHA (n=2) or showed non-specific secretion in PBS tube (n=2). The results of this study showed that IGRA is a useful new tool that can assess

  3. Screening for epitope specificity directly on culture supernatants in the early phase of monoclonal antibody production by an ELISA with biotin-labeled antigen.

    Science.gov (United States)

    Andersen, Ditte C; Jensen, Charlotte H; Gregersen, Annemette; Brandt, Jette; Kliem, Anette; Skjødt, Karsten; Koch, Claus; Teisner, Børge

    2004-01-01

    This report describes an assay for comparison of epitope specificity in groups of monoclonal antibodies against a given antigen. The only prerequisite is the biotin-labeled antigen. One of the monoclonal antibodies is captured onto a plastic surface via a rabbit anti-mouse Ig, and the other preincubated with biotinylated antigen. When the two antibodies react with the same epitope subsequent binding of the biotin-labeled antigen is abolished (inhibition). In the cases where no inhibition was observed, the two antibodies were considered to react with distinct, independent epitopes. The obvious advantages using this assay, are that it can be performed directly on culture supernatants in the early phase of monoclonal antibody production, and also works for antigens with repetitive epitopes. Moreover, the bonus effect, i.e., a signal in excess of the reference signal when sets of monoclonal antibodies with different epitope specificity are compared, gives a relative measure of affinity.

  4. Quantification of an Epstein-Barr virus-associated membrane antigen component

    International Nuclear Information System (INIS)

    North, J.R.; Morgan, A.J.; Thompson, J.L.; Epstein, M.A.

    1982-01-01

    A method is described for the preparation of a 125 I-labelled membrane antigen (MA) component (gp340) from B95-8 cell membranes using sodium dodecyl sulphate-polyacrylamide gel electrophoresis (SDS-PAGE). Good yields of antigenic material were obtained when renaturation of the [ 125 I]gp340 was carried out by removal of SDS in the presence of urea and subsequent removal of the urea. The availability of purified, radiolabelled gp340 has provided the essential basis for the development of a radioimmunoassay which, for the first time, permits quantification of this antigen. The assay has been used to demonstrate that cell membrane MA is a better source of gp340 for large-scale work than is the Epstein-Barr virus envelope and to measure the increase in expression of gp340 following treatment of cells with 12-O-tetradecanoyl-phorbol-13-acetate (TPA). (Auth.)

  5. Molecular typing for blood group antigens within 40 minutes by direct PCR from plasma or serum

    Science.gov (United States)

    Wagner, Franz Friedrich; Flegel, Willy Albert; Bittner, Rita; Döscher, Andrea

    2016-01-01

    Determining blood group antigens by serological methods may be unreliable in certain situations, such as in patients after chronic or massive transfusion. Red cell genotyping offers a complementary approach, but current methods may take much longer than conventional serological typing, limiting their utility in urgent situations. To narrow this gap, we devised a rapid method using direct polymerase chain reaction (PCR) amplification while avoiding the DNA extraction step. DNA was amplified by PCR directly from plasma or serum of blood donors followed by a melting curve analysis in a capillary rapid-cycle PCR assay. We evaluated the single nucleotide polymorphisms underlying the clinically relevant Fya, Fyb, Jka and Jkb antigens, with our analysis being completed within 40 min of receiving a plasma or serum sample. The positive predictive value was 100% and the negative predictive value at least 84%. Direct PCR with melting point analysis allowed faster red cell genotyping to predict blood group antigens than any previous molecular method. Our assay may be used as a screening tool with subsequent confirmatory testing, within the limitations of the false-negative rate. With fast turnaround times, the rapid-cycle PCR assay may eventually be developed and applied to red cell genotyping in the hospital setting. PMID:27991657

  6. Tumor markers kits development for use in radioimmunometric assays

    International Nuclear Information System (INIS)

    Ahmed, B.

    1997-01-01

    The immunoassays such as RIA and IRMA are now widely used through the world for the quantitation of a variety of substances in the biological fluid for their high sensibility and specificity which required simple equipments. These techniques are also very used in Algeria for an effective amelioration of public heath The assays kits of RIA/IRMA of thyroid hormones are the most used, followed by peptidic hormones, steroids hormones and IRMA Tumor Markers (T.M) kits. In spite of the important demand, of tumor markers kits for the diagnosis and follow up of cancers their use are always insufficient due to the high cost. The research contract programme proposed by IAEA on the theme 'The Developments of IRMA Tumor Markers Kits' of prostate specific Antigen (PSA) and Tissue Polypeptide Specific Antigen (TPS) will allowed us to produce locally with best quality-price, the main reagents for PSA and TPS IRMA assays kits for diagnosis and follow up the prostate and breast cancers which are very spready in the country. This report include the following points: Generalities on the use of tumor markers in Algeria, programme for the Development of the PSA IRMA assay (schedule of protocols applied for each reagents; annual planning for assessing the programme activities) and conclusion

  7. Performance of seven serological assays for diagnosing tularemia

    Science.gov (United States)

    2014-01-01

    Background Tularemia is a rare zoonotic disease caused by the Gram-negative bacterium Francisella tularensis. Serology is frequently the preferred diagnostic approach, because the pathogen is highly infectious and difficult to cultivate. The aim of this retrospective study was to determine the diagnostic accuracy of tularemia specific tests. Methods The Serazym®Anti-Francisella tularensis ELISA, Serion ELISA classic Francisella tularensis IgG/IgM, an in-house ELISA, the VIRapid® Tularemia immunochromatographic test, an in-house antigen microarray, and a Western Blot (WB) assay were evaluated. The diagnosis tularemia was established using a standard micro-agglutination assay. In total, 135 sera from a series of 110 consecutive tularemia patients were tested. Results The diagnostic sensitivity and diagnostic specificity of the tests were VIRapid (97.0% and 84.0%), Serion IgG (96.3% and 96.8%), Serion IgM (94.8% and 96.8%), Serazym (97.0% and 91.5%), in-house ELISA (95.6% and 76.6%), WB (93.3% and 83.0%), microarray (91.1% and 97.9%). Conclusions The diagnostic value of the commercial assays was proven, because the diagnostic accuracy was >90%. The diagnostic sensitivity of the in-house ELISA and the WB were acceptable, but the diagnostic accuracy was <90%. Interestingly, the antigen microarray test was very specific and had a very good positive predictive value. PMID:24885274

  8. Radioimmunoassay for antibodies against surface membrane antigens using adhering cells

    Energy Technology Data Exchange (ETDEWEB)

    Tax, A; Manson, L A [Wistar Inst. of Anatomy and Biology, Philadelphia, Pa. (USA)

    1976-07-01

    A radioimmunoassay using cells adhering to plastic is described. In this assay, A-10 mammary carcinoma attached to the surface of plastic in microtiter plates were permitted to bind antibody and the bound antibody was detected with purified rabbit /sup 125/I-antimouse-Fab. The bound radioactive material was eluted with glycine-HCl buffer (pH 2.5), and the acid eluates were counted in a gamma counter. This assay can be used to detect cytolic or noncytolic antibody to cell surface antigens in studies with any tumor or normal cell that will adhere to a solid surface.

  9. Effect of radiation on the expression of tumor-associated antigens of human lung adenocarcinoma cells

    International Nuclear Information System (INIS)

    Hareyama, Masato

    1988-01-01

    We studied the effects of irradiation on the expression of a tumor-associated antigen (YH206 antigen) of cultured human lung adenocarcinoma A549 cells by using enzyme-linked immunosorbent assay (ELISA) and flow cytometry. YH206 antigen is preferentially expressed on adenocarcinoma cells. Irradiation of A549 cells remarkably increased the expression of YH206 antigen on the cell surface and the level of the antigen in the culture supernatant as well as in the cell lysate, whereas it significantly affected the expression of HLA (MHC-class I) antigen on the same cells. The expression of HLA antigen on the cell was also increased after treatment of the cells with interferon-γ. In an additional experiment, cells were stained simultaneously for surface antigens (fluorescein coupled antibodies) and for DNA content (propidium iodide), and then dual parameter measurements were performed by flow cytometry to analyse the relationship between antigen levels and the cell cycle. YH206 antigen and HLA antigen increased more in the S and G 2 /M phases of the cell cycle than in G 0 /G 1 . The expression of YH206 antigen was enhanced in the S and G 2 /M phases by irradiation, whereas the expression of HLA antigen was enhanced in each phase of the cell cycle with irradiation or IFN. These results suggest that irradiation plays a key role in the change of the expression of certain tumor-associated antigens. (author)

  10. Immunolocalization and immunodetection of the excretory/secretory (ES) antigens of Fasciola gigantica.

    Science.gov (United States)

    Khan, M A Hannan; Ullah, Rizwan; Rehman, Abdur; Rehman, Lubna; P A, Ahammed Shareef; Abidi, S M A

    2017-01-01

    The digenetic trematode Fasciola gigantica is a parasite of great agricultural and economic importance. Along with Fasciola hepatica, F. gigantica incurs huge economic losses to the agricultural sector. Because of unavailability of an effective and commercial vaccine, the earliest diagnosis of the disease is the only way to control the disease. The conventional coprological techniques are able to detect the disease only after the parasites get matured and starts releasing their eggs with the faeces of host, therefore prepatent infection remain undiagnosed. The alternative method is by serological tests that uses circulatory antigens. Despite high sensitivity, their reliability is quite low because of the common antigens shared between different helminth parasites. To overcome this, investigation was shifted to identify the copro-antigens which could be more sensitive and reliable. In the present study, we tried to identify some of the immunodominant proteins from the Excretory Secretory (ES) product of F. gigantica which can be further characterized and used for early detection of infection and also as drug and vaccine candidates. The ES products of F. gigantica were collected and used for raising the polyclonal antibody in rabbit. The polypeptide profile was generated as well as immunogenic polypeptides were identified. The Source of ES antigen was immunolocalized using confocal microscopy and dot blot assay was performed to diagnose field infection. The polypeptide profile of ES products revealed a total of 24 polypeptides out of which 12 immunogenic polypeptides were identified by western blotting. Confocal micrographs showed the immunolocalization of antigens in the intestinal caecae, vitalline glands, gonads as well as in the tegument of the worm. The dot blot assay confirmed the utility of ES products for the detection of field infection. Subsequently, cross reactivity was found negative with Gigantocotyle explanatum; an amphitome parasite of same habitat

  11. Immunolocalization and immunodetection of the excretory/secretory (ES antigens of Fasciola gigantica.

    Directory of Open Access Journals (Sweden)

    M A Hannan Khan

    Full Text Available The digenetic trematode Fasciola gigantica is a parasite of great agricultural and economic importance. Along with Fasciola hepatica, F. gigantica incurs huge economic losses to the agricultural sector. Because of unavailability of an effective and commercial vaccine, the earliest diagnosis of the disease is the only way to control the disease. The conventional coprological techniques are able to detect the disease only after the parasites get matured and starts releasing their eggs with the faeces of host, therefore prepatent infection remain undiagnosed. The alternative method is by serological tests that uses circulatory antigens. Despite high sensitivity, their reliability is quite low because of the common antigens shared between different helminth parasites. To overcome this, investigation was shifted to identify the copro-antigens which could be more sensitive and reliable. In the present study, we tried to identify some of the immunodominant proteins from the Excretory Secretory (ES product of F. gigantica which can be further characterized and used for early detection of infection and also as drug and vaccine candidates. The ES products of F. gigantica were collected and used for raising the polyclonal antibody in rabbit. The polypeptide profile was generated as well as immunogenic polypeptides were identified. The Source of ES antigen was immunolocalized using confocal microscopy and dot blot assay was performed to diagnose field infection. The polypeptide profile of ES products revealed a total of 24 polypeptides out of which 12 immunogenic polypeptides were identified by western blotting. Confocal micrographs showed the immunolocalization of antigens in the intestinal caecae, vitalline glands, gonads as well as in the tegument of the worm. The dot blot assay confirmed the utility of ES products for the detection of field infection. Subsequently, cross reactivity was found negative with Gigantocotyle explanatum; an amphitome parasite

  12. Evaluation of twenty rapid antigen tests for the detection of human influenza A H5N1, H3N2, H1N1, and B viruses.

    Science.gov (United States)

    Taylor, Janette; McPhie, Kenneth; Druce, Julian; Birch, Chris; Dwyer, Dominic E

    2009-11-01

    Twenty rapid antigen assays were compared for their ability to detect influenza using dilutions of virus culture supernatants from human isolates of influenza A H5N1 (clade 1 and 2 strains), H3N2 and H1N1 viruses, and influenza B. There was variation amongst the rapid antigen assays in their ability to detect different influenza viruses. Six of the 12 assays labeled as distinguishing between influenza A and B had comparable analytical sensitivities for detecting both influenza A H5N1 strains, although their ability to detect influenza A H3N2 and H1N1 strains varied. The two assays claiming H5 specificity did not detect either influenza A H5N1 strains, and the two avian influenza-specific assays detected influenza A H5N1, but missed some influenza A H3N2 virus supernatants. Clinical trials of rapid antigen tests for influenza A H5N1 are limited. For use in a pandemic where novel influenza strains are circulating (such as the current novel influenza A H1N1 09 virus), rapid antigen tests should ideally have comparable sensitivity and specificity for the new strains as for co-circulating seasonal influenza strains.

  13. Performance Assessment of Four Chimeric Trypanosoma cruzi Antigens Based on Antigen-Antibody Detection for Diagnosis of Chronic Chagas Disease.

    Directory of Open Access Journals (Sweden)

    Fred Luciano Neves Santos

    Full Text Available The performance of serologic tests in chronic Chagas disease diagnosis largely depends on the type and quality of the antigen preparations that are used for detection of anti-Trypanosoma cruzi antibodies. Whole-cell T. cruzi extracts or recombinant proteins have shown variation in the performance and cross-reactivity. Synthetic chimeric proteins comprising fragments of repetitive amino acids of several different proteins have been shown to improve assay performances to detect Chagasic infections. Here, we describe the production of four chimeric T. cruzi proteins and the assessment of their performance for diagnostic purposes. Circular Dichroism spectra indicated the absence of well-defined secondary structures, while polydispersity evaluated by Dynamic Light Scattering revealed only minor aggregates in 50 mM carbonate-bicarbonate (pH 9.6, demonstrating that it is an appropriate buffering system for sensitizing microplates. Serum samples from T. cruzi-infected and non-infected individuals were used to assess the performance of these antigens for detecting antibodies against T. cruzi, using both enzyme-linked immunosorbent assay and a liquid bead array platform. Performance parameters (AUC, sensitivity, specificity, accuracy and J index showed high diagnostic accuracy for all chimeric proteins for detection of specific anti-T. cruzi antibodies and differentiated seropositive individuals from those who were seronegative. Our data suggest that these four chimeric proteins are eligible for phase II studies.

  14. Detection of urinary excreted fungal galactomannan-like antigens for diagnosis of invasive aspergillosis.

    Directory of Open Access Journals (Sweden)

    Simon F Dufresne

    Full Text Available Mortality associated with invasive aspergillosis (IA remains high, partly because of delayed diagnosis. Detection of microbial exoantigens, released in serum and other body fluids during infection, may help timely diagnosis. In course of IA, Aspergillus galactomannan (GM, a well established polysaccharide biomarker, is released in body fluids including urine. Urine is an abundant, safely collected specimen, well-suited for point-of-care (POC testing, which could play an increasing role in screening for early disease. Our main objective was to demonstrate GM antigenuria as a clinically relevant biological phenomenon in IA and establish proof-of-concept that it could be translated to POC diagnosis. Utilizing a novel IgM monoclonal antibody (MAb476 that recognizes GM-like antigens from Aspergillus and other molds, we demonstrated antigenuria in an experimental animal IA model (guinea pig, as well as in human patients. In addition, we investigated the chemical nature of the urinary excreted antigen in human samples, characterized antigen detection in urine by immunoassays, described a putative assay inhibitor in urine, and indicated means of alleviation of the inhibition. We also designed and used a lateral flow immunochromatographic assay to detect urinary excreted antigen in a limited number of IA patient urine samples. In this study, we establish that POC diagnosis of IA based on urinary GM detection is feasible. Prospective studies will be necessary to establish the performance characteristics of an optimized device and define its optimal clinical use.

  15. Use of radio-immuno-inhibition assay for the study of the y, d and w determinants of hepatitis B surface antigen

    Energy Technology Data Exchange (ETDEWEB)

    Donea-Debroise, B; Brocteur, J; Andre, A; Remacle, M B [Liege Univ. (Belgium)

    1979-01-01

    A radioimmunoassay determination of the HBs antigen subtypes is discussed, this simple but effective technique was used in association with the use of the Austria II kit (Abbott Laboratories). This method consists of an inhibition reaction of the Austria II test, by previous incubation of the antigen to be subtyped with a monospecific antibody. With this method we were able to distinguish the y and the d antigens as well as the w1, w3, w4 determinants of hepatitis B surface antigen. We have included a frequency table of the various HBs subtypes found among donor and patient populations in Liege.

  16. Anti-Taenia solium monoclonal antibodies for the detection of parasite antigens in body fluids from patients with neurocysticercosis.

    Science.gov (United States)

    Paredes, Adriana; Sáenz, Patricia; Marzal, Miguel W; Orrego, Miguel A; Castillo, Yesenia; Rivera, Andrea; Mahanty, Siddhartha; Guerra-Giraldez, Cristina; García, Hector H; Nash, Theodore E

    2016-07-01

    Neurocysticercosis (NCC), an infection of the brain by Taenia solium (Ts) cysts, is the most common cause of adult-onset epilepsy in developing countries. Serological testing consists primarily of varying methods to detect antibodies in body fluids and more recently antigen (Ag) detection assays to identify individuals or animals with viable parasites. Antigen assays currently in use employ monoclonal antibodies (mAbs) raised against T. saginata, which have known cross reactivity to animal cestodes but are highly specific in human samples. We produced, characterized and tested 21 mAbs raised against T. solium whole cyst antigens, vesicular fluid or excretory secretory products. Reactivity of the TsmAbs against specific cyst structures was determined using immunofluorescence and immunohistochemistry on histological sections of Ts muscle cysts. Four TsmAbs reacted to vesicular space alone, 9 to the neck and cyst wall, one to the neck and vesicular space and 7 to the neck, cyst wall and vesicular space. An in-house ELISA assay to detect circulating Ts antigen, using the TsmAbs as capture antibodies and a rabbit polyclonal anti-Ts whole cyst antibody as a detector antibody demonstrated that eight of the 21 TsmAbs detected antigens in known NCC-positive human sera and three of these also in urine samples. Reactivity was expressed as normalized ratios of optical densities (OD positive control/OD negative control). Three TsmAbs had ratios >10 and five between 2 and 10. The TsmAbs have potential utility for the diagnosis and post-treatment monitoring of patients with viable NCC infections. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Comparison of non-magnetic and magnetic beads in bead-based assays

    NARCIS (Netherlands)

    Hansenová Maňásková, S.; van Belkum, A.; Endtz, H.P.; Bikker, F.J.; Veerman, E.C.I.; van Wamel, W.J.B.

    2016-01-01

    Multiplex bead-based flow cytometry is an attractive way for simultaneous, rapid and cost-effective analysis of multiple analytes in a single sample. Previously, we developed various bead-based assays using non-magnetic beads coated with Staphylococcus aureus and Streptococcus pneumoniae antigens

  18. Antigenic stability of pecan [Carya illinoinensis (Wangenh.) K. Koch] proteins: effects of thermal treatments and in vitro digestion.

    Science.gov (United States)

    Venkatachalam, Mahesh; Teuber, Suzanne S; Peterson, W Rich; Roux, Kenneth H; Sathe, Shridhar K

    2006-02-22

    Rabbit polyclonal antibody-based inhibition ELISA as well as immunoblotting analyses of proteins extracted from variously processed pecans (cv. Desirable) indicate that pecan proteins are antigenically stable. Pecan antigens were more sensitive to moist heat than dry heat processing treatments. SDS-PAGE and immunoblotting analysis of the native and heat-denatured proteins that were previously subjected to in vitro simulated gastric fluid digestions indicate that stable antigenic peptides were produced. Both enzyme-to-substrate ratio and digestion time were influential in determining the stability of pecan polypeptides. The stable antigenic polypeptides may serve as useful markers in developing assays suitable for the detection of trace amounts of pecans in foods.

  19. Characterisation of surface antigens of Strongylus vulgaris of potential immunodiagnostic importance.

    Science.gov (United States)

    Nichol, C; Masterson, W J

    1987-08-01

    When antigens prepared by detergent washes of Strongylus vulgaris and Parascaris equorum were probed in an enzyme-linked immunosorbent assay test with horse sera from single species infections of S. vulgaris and P. equorum, a high degree of cross-reaction between the species was demonstrated. Western blot analysis of four common horse nematode species showed a large number of common antigens when probed with horse infection sera. Antisera raised in rabbits against the four species, including S. vulgaris, were also found to cross-react considerably. Rabbit anti-S. vulgaris sera were affinity adsorbed over a series of affinity chromatography columns, bound with cross-reactive surface antigens, to obtain S. vulgaris-specific antisera and thereby identify S. vulgaris-specific antigens by Western blotting. These studies revealed potentially specific antigens of apparent molecular weights of 100,000, 52,000, and 36,000. Of these bands, only the 52 kDa and 36 kDa appeared to be found on the surface as judged by 125I-labelling of intact worms by the Iodogen method, although neither protein was immunoprecipitated by horse infection sera. Finally, immunoprecipitation of in vitro translated proteins derived from larval S. vulgaris RNA suggests that two proteins may be parasite-derived. These findings are discussed both with respect to the surface of S. vulgaris and to the use of these species-specific antigens in immunodiagnosis.

  20. System and method for detecting components of a mixture including a valving scheme for competition assays

    Science.gov (United States)

    Koh, Chung-Yan; Piccini, Matthew E.; Singh, Anup K.

    2017-07-11

    Examples are described including measurement systems for conducting competition assays. A first chamber of an assay device may be loaded with a sample containing a target antigen. The target antigen in the sample may be allowed to bind to antibody-coated beads in the first chamber. A control layer separating the first chamber from a second chamber may then be opened to allow a labeling agent loaded in a first portion of the second chamber to bind to any unoccupied sites on the antibodies. A centrifugal force may then be applied to transport the beads through a density media to a detection region for measurement by a detection unit.

  1. System and method for detecting components of a mixture including a valving scheme for competition assays

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan; Piccini, Matthew E.; Singh, Anup K.

    2017-09-19

    Examples are described including measurement systems for conducting competition assays. A first chamber of an assay device may be loaded with a sample containing a target antigen. The target antigen in the sample may be allowed to bind to antibody-coated beads in the first chamber. A control layer separating the first chamber from a second chamber may then be opened to allow a labeling agent loaded in a first portion of the second chamber to bind to any unoccupied sites on the antibodies. A centrifugal force may then be applied to transport the beads through a density media to a detection region for measurement by a detection unit.

  2. Detection of autoimmune antibodies in localized scleroderma by synthetic oligonucleotide antigens

    DEFF Research Database (Denmark)

    Samuelsen, Simone; Jørgensen, Christian Damsgaard; Mellins, Elizabeth D

    2018-01-01

    In this study, we developed a series of synthetic oligonucleotides that allowed us to investigate the details on the antigen recognition by autoimmune antibodies in localized scleroderma subjects. Besides dramatically improved analytical specificity of the assay, our data suggests a potential...... linking for antibodies to DNA to the biological status of disease state in localized scleroderma. Moreover, introducing chemical modifications into short synthetic deoxyribonucleic acid (DNA) and ribonucleic acid (RNA) molecules completely changed the binding titers of corresponding antibodies...... and their clinical relevance. The strongest observed effect was registered for the localized scleroderma skin damage index (LoSDI) on the IgG antibodies to TC dinucleotide-rich double-stranded antigen (p

  3. A molecular assay for sensitive detection of pathogen-specific T-cells.

    Directory of Open Access Journals (Sweden)

    Victoria O Kasprowicz

    Full Text Available Here we describe the development and validation of a highly sensitive assay of antigen-specific IFN-γ production using real time quantitative PCR (qPCR for two reporters--monokine-induced by IFN-γ (MIG and the IFN-γ inducible protein-10 (IP10. We developed and validated the assay and applied it to the detection of CMV, HIV and Mycobacterium tuberculosis (MTB specific responses, in a cohort of HIV co-infected patients. We compared the sensitivity of this assay to that of the ex vivo RD1 (ESAT-6 and CFP-10-specific IFN-γ Elispot assay. We observed a clear quantitative correlation between the two assays (P<0.001. Our assay proved to be a sensitive assay for the detection of MTB-specific T cells, could be performed on whole blood samples of fingerprick (50 uL volumes, and was not affected by HIV-mediated immunosuppression. This assay platform is potentially of utility in diagnosis of infection in this and other clinical settings.

  4. Identification of antigen-specific human monoclonal antibodies using high-throughput sequencing of the antibody repertoire.

    Science.gov (United States)

    Liu, Ju; Li, Ruihua; Liu, Kun; Li, Liangliang; Zai, Xiaodong; Chi, Xiangyang; Fu, Ling; Xu, Junjie; Chen, Wei

    2016-04-22

    High-throughput sequencing of the antibody repertoire provides a large number of antibody variable region sequences that can be used to generate human monoclonal antibodies. However, current screening methods for identifying antigen-specific antibodies are inefficient. In the present study, we developed an antibody clone screening strategy based on clone dynamics and relative frequency, and used it to identify antigen-specific human monoclonal antibodies. Enzyme-linked immunosorbent assay showed that at least 52% of putative positive immunoglobulin heavy chains composed antigen-specific antibodies. Combining information on dynamics and relative frequency improved identification of positive clones and elimination of negative clones. and increase the credibility of putative positive clones. Therefore the screening strategy could simplify the subsequent experimental screening and may facilitate the generation of antigen-specific antibodies. Copyright © 2016 Elsevier Inc. All rights reserved.

  5. Rapid solid-phase radioimmunoassay for detection of equine infectious anemia viral antigen and antibodies: parameters involved in standardization

    International Nuclear Information System (INIS)

    Horenstein, A.L.; Feinstein, R.E.

    1985-01-01

    Solid-phase radioimmunoassays (SPRIA) are described for the detection of equine infectious anemia (EIA) viral antigen and antibodies. Protein-antigen P29 currently used in the agar-gel immunodiffusion (AGID) test was used as antigen in the SPRIA. The specificity of the reaction was assessed by inhibition with the antigen. The reaction of immune serum against EIA-virus antigen adsorbed to the wells, was completely inhibited by the antigen in solution. This property was applied in an indirect competitive SPRIA for the detection of viral protein P29. The detection threshold of the SPRIA for EIA virus protein was about 5 ng and about 1 ng of antibody can be detected. The assay is rapid, specific and sensitive and allows the testing of multiple serum samples with the advantage of employing a single secondary labelled antibody. (orig.)

  6. Detection of antibodies to Actinobacillus pleuropneumoniae serotype 12 in pig serum using a blocking enzyme-linked immunosorbent assay

    DEFF Research Database (Denmark)

    Andresen, Lars Ole; Klausen, Joan; Barfod, Kristen

    2002-01-01

    and from herds declared free of infection with Ap. The Ap serotype 12 blocking ELISA showed a herd sensitivity of 0.77 (95% confidence interval, 0.62-0.88) and a herd specificity of 1.00 (0.95-1.00) with a cut-off value at 40% relative absorbance or 60% inhibition. The assay may be used advantageously......The objective was to develop a blocking enzyme-linked immunosorbent assay (ELISA) for detection of antibodies to Actinobacillus pleuropneumoniae (Ap) serotype 12 in pig serum. Lipopolysaccharide (LPS) from Ap serotype 12 was purified and used as antigen in the assay. Antibodies to the LPS antigen...... in samples of pig serum were detected by inhibition of the binding of polyclonal rabbit antibodies raised against Ap serotype 12. The assay was evaluated against sera from experimentally infected pigs, from pig herds naturally infected with Ap and from herds declared free of Ap serotypc 12 infection...

  7. Radioisotopic 51Cr-leukocyte adherence inhibition (LAI) assay. I

    International Nuclear Information System (INIS)

    Tsang, P.H.; Tangnavarad, K.; Lesnick, G.; Holland, J.F.; Bekesi, J.G.; Perloff, M.

    1980-01-01

    A simplified radioisotopic leukocyte adherence inhibition assay ( 51 Cr-LAI assay) was used to determine tumor-directed immune responses in patients with cancer of the breast. Essential steps in development of this assay are the standardization of conditions for optimal 51 Cr uptake by peripheral blood lymphocytes (PBL) and the inclusion of autologous or normal AB serum in the incubation media. A dextrose salt mixture (GNK) was found to enhance intracellular uptake of 51 Cr significantly (8-fold) without affecting viability of the cells or without causing selective loss of lymphocyte subpopulations. The presence of 10% autologous or normal AB serum prevented non-specific LAI responses to unrelated tumor antigens. Experimental results are presented and it is seen that this short term (4 h) 51 Cr-LAI assay provides reproducible and specific results analogous to those using tube-LAI assay. The test has the advantages of being accurate, sensitive and free from technical bias. (Auth.)

  8. Improved performance of a double antibody radioimmunoassay for carcinoembryonic antigen

    International Nuclear Information System (INIS)

    Zimmerman, R.

    1979-01-01

    A new double antibody solid-phase radioimmunoassay (RIA) for carcinoembryonic antigen (CEA) is critically analyzed. The aim of the study was 4-fold: (a) to define the level of sensitivity (a comparison of 3 different assay procedures revealed that the author's sequential assay was more sensitive than most previously reported RIAs, while competitive and non-equilibrium assay had wider measuring ranges); (b) to analyze recoveries of CEA in either serum, plasma or urine (the recovery , even in urine, was very close to expected values, indicating that no CEA is lost or degraded during brief storage or in the extraction procedure); (c) to evaluate inter- and intra-assay variations, since most clinical management is dependent on serial assays rather than single determinations. The coefficients of variation were low both within and between assays. A change of 3 ng CEA is required for significant change (>2 S.D.) at the normal serum level which is 16 ng CEA/ml in the authors assay. At levels above normal, a change of 4 ng is required; (d) the assay was also developed for determination of CEA levels in a large series of perchlorid acid treated serum, plasma or urine samples. This forms the basis for an assay suitable for serial assays with high sensitivity and accuracy in various neoplastic diseases. (Auth.)

  9. Bordetella bronchiseptica antigen enhances the production of Mycoplasma hyopneumoniae antigen-specific immunoglobulin G in mice.

    Science.gov (United States)

    Yim, Seol-Hwa; Hahn, Tae-Wook; Joo, Hong-Gu

    2017-09-30

    We previously demonstrated that Bordetella ( B .) bronchiseptica antigen (Ag) showed high immunostimulatory effects on mouse bone marrow cells (BMs) while Mycoplasma ( M .) hyopneumoniae Ag showed low effects. The focus of this study was to determine if B. bronchiseptica Ag can enhance the M. hyopneumoniae Ag-specific immune response and whether the host's immune system can recognize both Ags. MTT assay results revealed that each or both Ags did not significantly change BM metabolic activity. Flow cytometry analysis using carboxyfluorescein succinimidyl ester showed that B. bronchiseptica Ag can promote the division of BMs. In cytokine and nitric oxide (NO) assays, B. bronchiseptica Ag boosted production of tumor necrosis factor-alpha in M. hyopneumoniae Ag-treated BMs, and combined treatment with both Ags elevated the level of NO in BMs compared to that from treatment of M. hyopneumoniae Ag alone. Immunoglobulin (Ig)G enzyme-linked immunosorbent assay using the sera of Ag-injected mice clearly indicated that B. bronchiseptica Ag can increase the production of M. hyopneumoniae Ag-specific IgG. This study provided information valuable in the development of M. hyopneumoniae vaccines and showed that B. bronchiseptica Ag can be used both as a vaccine adjuvant and as a vaccine Ag.

  10. Prostate-specific antigen superior serum marker for prostatic carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Heaney, J A; Allen, M A; Keane, T; Duffy, J J

    1987-05-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM/sup R/) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable.

  11. Prostate-specific antigen superior serum marker for prostatic carcinoma

    International Nuclear Information System (INIS)

    Heaney, J.A.; Allen, M.A.; Keane, T.; Duffy, J.J.

    1987-01-01

    A new immunoradiometric assay based on dual monoclonal antibody reaction system (Hybritech-TANDEM R ) was used to measure serum levels of prostate-specific antigen (PSA) and prostatic acid phosphatase (PAP) in 39 patients with prostatic carcinoma (CaP), in 57 with benign prostatic hyperplasia (BPH) and in 14 without prostatic disease. Serum PSA was elevated in 82% of patients with CaP while PAP was elevated in only 54%. In this and other studies, PSA is superior to conventional serum markers in sensitivity, prediction of CaP stage and in longitudinal monitoring of disease. A 16% false positive rate precludes PSA as a screening test. The assay used was found to be simple and reliable. (author)

  12. Carcinoma-associated antigens

    International Nuclear Information System (INIS)

    Bartorelli, A.; Accinni, R.

    1981-01-01

    This invention relates to novel antigens associated with breast carcinoma, anti-sera specific to said antigens, 125 I-labeled forms of said antigens and methods of detecting said antigens in serum or plasma. The invention also relates to a diagnostic kit containing standardised antigens or antisera or marked forms thereof for the detection of said antigens in human blood, serum or plasma. (author)

  13. Immunity to tumour antigens.

    Science.gov (United States)

    Li, Geng; Ali, Selman A; McArdle, Stephanie E B; Mian, Shahid; Ahmad, Murrium; Miles, Amanda; Rees, Robert C

    2005-01-01

    During the last decade, a large number of human tumour antigens have been identified. These antigens are classified as tumour-specific shared antigens, tissue-specific differentiation antigens, overexpressed antigens, tumour antigens resulting from mutations, viral antigens and fusion proteins. Antigens recognised by effectors of immune system are potential targets for antigen-specific cancer immunotherapy. However, most tumour antigens are self-proteins and are generally of low immunogenicity and the immune response elicited towards these tumour antigens is not always effective. Strategies to induce and enhance the tumour antigen-specific response are needed. This review will summarise the approaches to discovery of tumour antigens, the current status of tumour antigens, and their potential application to cancer treatment.

  14. Demonstration of tumor-associated antigens in dogs

    International Nuclear Information System (INIS)

    Warren, R.P.; Tsoi, M.S.; Henderson, B.H.; Weiden, P.L.; Storb, R.

    1975-01-01

    Procedures for the 51 Cr release assay using labeled L cells or lymphocytes and the indirect leukocyte migration test are described. These assays appear capable of detecting cellular immunity against tumor associated antigens in dogs. In 8 of 14 instances, lymphocyte-mediated cytotoxicity to autochthonous L cells was found as measured by 51 Cr release, and lymphocytes from 12 of 24 dogs produced the migration inhibition factor (MIF) when cultured with autochthonous tumor cells. Chromium-51 release occurred with 4 h of exposure of effector cells to target cells, suggesting that the immunity detected in the tumor dogs against their tumors is also present in vivo. With the leukocyte migration test, however, consistent MIF production was achieved only after 3 to 6 days in culture, suggesting that in vitro sensitization may result in increased MIF production

  15. A radioimmunoassay for antibodies against surface membrane antigens using adhering cells

    International Nuclear Information System (INIS)

    Tax, A.; Manson, L.A.

    1976-01-01

    A radioimmunoassay using cells adhering to plastic is described. In this assay, A-10 mammary carcinoma attached to the surface of plastic in microtiter plates were permitted to bind antibody and the bound antibody was detected with purified rabbit 125 I-antimouse-Fab. The bound radioactive material was eluted with glycine-HCl buffer (pH 2.5), and the acid eluates were counted in a gamma counter. This assay can be used to detect cytolic or noncytolic antibody to cell surface antigens in studies with any tumor or normal cell that will adhere to a solid surface

  16. Characterization and standardization of Sabin based inactivated polio vaccine: proposal for a new antigen unit for inactivated polio vaccines.

    Science.gov (United States)

    Westdijk, Janny; Brugmans, Debbie; Martin, Javier; van't Oever, Aart; Bakker, Wilfried A M; Levels, Lonneke; Kersten, Gideon

    2011-04-18

    GMP-batches of Sabin-IPV were characterized for their antigenic and immunogenic properties. Antigenic fingerprints of Sabin-IPV reveal that the D-antigen unit is not a fixed amount of antigen but depends on antibody and assay type. Instead of the D-antigen unit we propose standardization of IPV based on a combination of protein amount for dose and D-antigenicity for quality of the vaccine. Although Sabin-IPV type 2 is less immunogenic than regular wild type IPV type 2, the immunogenicity (virus neutralizing titers) per microgram antigen for Sabin-IPV type 2 is in the same order as for wild type serotypes 1 and 3. The latter observations are in line with data from human trials. This suggests that a higher dose of Sabin-IPV type 2 to compensate for the lower rat immunogenicity may not be necessary. Copyright © 2011 Elsevier Ltd. All rights reserved.

  17. The Lumipulse G HBsAg-Quant assay for screening and quantification of the hepatitis B surface antigen.

    Science.gov (United States)

    Yang, Ruifeng; Song, Guangjun; Guan, Wenli; Wang, Qian; Liu, Yan; Wei, Lai

    2016-02-01

    Qualitative HBsAg assay is used to screen HBV infection for decades. The utility of quantitative assay is also rejuvenated recently. We aimed to evaluate and compare the performance of a novel ultra-sensitive and quantitative assay, the Lumipulse assay, with the Architect and Elecsys assays. As screening methods, specificity was compared using 2043 consecutive clinical routine samples. As quantitative assays, precision and accuracy were assessed. Sera from 112 treatment-naïve chronic hepatitis B patients, four patients undergoing antiviral therapy and one patient with acute infection were tested to compare the correlations. Samples with concurrent HBsAg/anti-HBs were also quantified. The Lumipulse assay precisely quantified ultra-low level of HBsAg (0.004 IU/mL). It identified additional 0.98% (20/2043) clinical samples with trance amount of HBsAg. Three assays displayed excellent linear correlations irrespective of genotypes and S-gene mutations (R(2)>0.95, PLumipulse assay did not yield higher HBsAg concentrations in samples with concomitant anti-HBs. Compared with other assays, the Lumipulse assay is sensitive and specific for detecting HBsAg. The interpretation of the extremely low-level results, however, is challenging. Quantitative HBsAg results by different assays are highly correlated, but they should be interpreted interchangeably only after conversion to eliminate the biases. Copyright © 2015 Elsevier B.V. All rights reserved.

  18. Recombinant Secreted Antigens from Mycoplasma hyopneumoniae Delivered as a Cocktail Vaccine Enhance the Immune Response of Mice

    Science.gov (United States)

    Galli, Vanessa; Simionatto, Simone; Marchioro, Silvana Beutinger; Klabunde, Gustavo Henrique Ferrero; Conceição, Fabricio Rochedo

    2013-01-01

    Mycoplasma hyopneumoniae is the etiological agent of porcine enzootic pneumonia (EP), which is a respiratory disease responsible for huge economic losses in the pig industry worldwide. The commercially available vaccines provide only partial protection and are expensive. Thus, the development of alternatives for the prophylaxis of EP is critical for improving pig health. The use of multiple antigens in the same immunization may represent a promising alternative. In the present study, seven secreted proteins of M. hyopneumoniae were cloned, expressed in Escherichia coli, and evaluated for antigenicity using serum from naturally and experimentally infected pigs. In addition, the immunogenicity of the seven recombinant proteins delivered individually or in protein cocktail vaccines was evaluated in mice. In Western blot assays and enzyme-linked immunosorbent assays, most of the recombinant proteins evaluated were recognized by convalescent-phase serum from the animals, indicating that they are expressed during the infectious process. The recombinant proteins were also immunogenic, and most induced a mixed IgG1/IgG2a humoral immune response. The use of these proteins in a cocktail vaccine formulation enhanced the immune response compared to their use as antigens delivered individually, providing evidence of the efficacy of the multiple-antigen administration strategy for the induction of an immune response against M. hyopneumoniae. PMID:23803903

  19. CELLISA: reporter cell-based immunization and screening of hybridomas specific for cell surface antigens.

    Science.gov (United States)

    Chen, Peter; Mesci, Aruz; Carlyle, James R

    2011-01-01

    Monoclonal antibodies (mAbs) specific for cell surface antigens are an invaluable tool to study immune receptor expression and function. Here, we outline a generalized reporter cell-based approach to the generation and high-throughput screening of mAbs specific for cell surface antigens. Termed CELLISA, this technology hinges upon the capture of hybridoma supernatants in mAb arrays that facilitate ligation of an antigen of interest displayed on BWZ reporter cells in the form of a CD3ζ-fusion chimeric antigen receptor (zCAR); in turn, specific mAb-mediated cross-linking of zCAR on BWZ cells results in the production of β-galactosidase enzyme (β-gal), which can be assayed colorimetrically. Importantly, the BWZ reporter cells bearing the zCAR of interest may be used for immunization as well as screening. In addition, serial immunizations employing additional zCAR- or native antigen-bearing cell lines can be used to increase the frequency of the desired antigen-specific hybridomas. Finally, the use of a cohort of epitope-tagged zCAR (e.g., zCAR(FLAG)) variants allows visualization of the cell surface antigen prior to immunization, and coimmunization using these variants can be used to enhance the immunogenicity of the target antigen. Employing the CELLISA strategy, we herein describe the generation of mAb directed against an uncharacterized natural killer cell receptor protein.

  20. Assignment of C1q-binding HLA antibodies as unacceptable HLA antigens avoids positive CDC-crossmatches prior to transplantation of deceased donor organs.

    Science.gov (United States)

    Juhl, David; Marget, Matthias; Hallensleben, Michael; Görg, Siegfried; Ziemann, Malte

    2017-03-01

    Soon, a virtual crossmatch shall replace the complement-dependent cytotoxicity (CDC) allocation crossmatch in the Eurotransplant region. To prevent positive CDC-crossmatches in the recipient centre, careful definition of unacceptable antigens is necessary. For highly sensitized patients, this is difficult by CDC alone. Assignment of all antibodies detected by sensitive assays, however, could prevent organ allocation. To assess the usefulness of the Luminex C1q-assay to prevent positive CDC-crossmatches, all CDC-crossmatches performed prior to deceased kidney transplantation in a 16-month-period were reviewed. Sera causing positive crossmatches were investigated by the C1q-assay. 31 out of 1432 crossmatches (2.2%) were positive. Sera involved in 26 positive crossmatches were available. C1q-binding donor-specific antibodies were detected in 19 sera (73.1%). The other sera were from recipients without any HLA antibodies detectable by CDC or common solid phase assays. Three patients had known Non-HLA antibodies causing positive CDC-results. Four crossmatches were only weak positive. Therefore, avoidance of donors with HLA antigens against whom C1q-binding antibodies were detected would have prevented all positive crossmatches due to HLA antibodies. Provided that all HLA specificities against which antibodies are detected by the Luminex C1q-assay are considered as unacceptable antigens, CDC-crossmatches prior to transplantation might safely be omitted in many patients. They should be maintained in highly immunized patients, however, for whom assignment of all C1q-positive antibodies as unacceptable antigens could lead to a significant delay or even prevention of transplantation. Copyright © 2017 Elsevier B.V. All rights reserved.

  1. Development of a dipstick assay for detection of Leishmania-specific canine antibodies

    NARCIS (Netherlands)

    Schallig, Henk D. F. H.; Cardoso, Luís; Hommers, Marieke; Kroon, Nel; Belling, Guus; Rodrigues, Manuela; Semião-Santos, Saul J.; Vetter, Hans

    2004-01-01

    A dipstick assay, based on Leishmania infantum antigen, for the rapid detection of Leishmania-specific antibodies in canine serum samples was developed and evaluated. After determination of optimal dipstick test conditions, test performance was compared with two existing serological tests, i.e., the

  2. Simple Objective Detection of Human Lyme Disease Infection Using Immuno-PCR and a Single Recombinant Hybrid Antigen

    Science.gov (United States)

    Halpern, Micah D.; Molins, Claudia R.; Schriefer, Martin

    2014-01-01

    A serology-based tiered approach has, to date, provided the most effective means of laboratory confirmation of clinically suspected cases of Lyme disease, but it lacks sensitivity in the early stages of disease and is often dependent on subjectively scored immunoblots. We recently demonstrated the use of immuno-PCR (iPCR) for detecting Borrelia burgdorferi antibodies in patient serum samples that were positive for Lyme disease. To better understand the performance of the Lyme disease iPCR assay, the repeatability and variability of the background of the assay across samples from a healthy population (n = 36) were analyzed. Both of these parameters were found to have coefficients of variation of Lyme disease patient serum samples (n = 12) demonstrated a strong correlation with that of 2-tier testing. Furthermore, a simplified iPCR approach using a single hybrid antigen and detecting only IgG antibodies confirmed the 2-tier diagnosis in the Lyme disease patient serum samples (n = 12). Validation of the hybrid antigen IgG iPCR assay using a blinded panel of Lyme disease and non-Lyme disease patient serum samples (n = 92) resulted in a sensitivity of 69% (95% confidence interval [CI], 50% to 84%), compared to that of the 2-tier analysis at 59% (95% CI, 41% to 76%), and a specificity of 98% (95% CI, 91% to 100%) compared to that of the 2-tier analysis at 97% (95% CI, 88% to 100%). A single-tier hybrid antigen iPCR assay has the potential to be an improved method for detecting host-generated antibodies against B. burgdorferi. PMID:24899074

  3. The use of radio-immuno-inhibition assay for the study of the y, d and w determinants of hepatitis B surface antigen

    International Nuclear Information System (INIS)

    Donea-Debroise, B.; Brocteur, J.; Andre, A.; Remacle, M.B.

    1979-01-01

    A radioimmunoassay determination of the HBs antigen subtypes is discussed, this simple but effective technique was used in association with the use of the Austria II kit (Abbott Laboratories). This method consists of an inhibition reaction of the Austria II test, by previous incubation of the antigen to be subtyped with a monospecific antibody. With this method we were able to distinguish the y and the d antigens as well as the w1, w3, w4 determinants of hepatitis B surface antigen. We have included a frequency table of the various HBs subtypes found among donor and patient populations in Liege

  4. Development of microLIPS (Luciferase Immunoprecipitation Systems): a novel microfluidic assay for rapid serum antibody detection

    Science.gov (United States)

    Chandrangsu, Matt; Burbelo, Peter D.; Iadarola, Michael J.; Smith, Paul D.; Morgan, Nicole Y.

    2012-06-01

    There is considerable interest in the development of rapid, point-of-care antibody detection for the diagnosis of infectious and auto-immune diseases. In this paper, we present work on the development of a self-contained microfluidic format for the Luciferase Immunoprecipitation Systems (LIPS) assay. Whereas the majority of immunoassays for antigen-specific antibodies employ either bacteria- or yeast-expressed proteins and require the use of secondary antibodies, the LIPS technique uses a fusion protein comprised of a Renilla luciferase reporter and the antigen of interest produced via mammalian cell culture, ensuring the addition of mammalian post-translational modifications. Patient serum is mixed with the fusion protein and passed over immobilized Protein A/G; after washing, the only remaining luciferase-tagged antigens are those retained by specific antibodies. These can be quantitatively measured using chemiluminescence upon the introduction of coelenterazine. The assay has been successfully employed for a wide variety of diseases in a microwell format. We report on a recent demonstration of rapid HSV-2 diagnosis with the LIPS assay in a microfluidic format, using one microliter of serum and obtaining results in under ten minutes. We will also discuss recent progress on two fronts, both aimed at the deployment of this technology in the field: first, simplifying assay operation through the automation of flow control using power-free means; and second, efforts to increase signal levels, primarily through strategies to increase antibody binding capacity, in order to move towards portable battery powered electronics.

  5. FULL-LENGTH PEPTIDE ASSAY OF ANTIGENIC PROFILE OF ENVELOPE PROTEINS FROM SIBERIAN ISOLATES OF HEPATITIS C VIRUS

    Directory of Open Access Journals (Sweden)

    A. A. Grazhdantseva

    2010-01-01

    Full Text Available Antigenic profiles of envelope glycoproteins of hepatitis C virus presented by three genotypes 1b, 2a/2c and 3a, which are most widespread in the territory of Russia and, in particular, in Novosibirsk, were studied using a panel of overlapping synthetic peptides. It was shown that highly immunogenic peptide epitopes of Е1 and Е2 proteins common for all HCV genotypes, are located in amino acid positions 250-260, 315-325 (Е1 protein, 390-400 (hypervariable region 1, 430-440, and 680-690 (Е2 protein. The greatest inter-genotypic differences were recorded in positions 280-290, 410-430 and 520-540. A novel antigenic determinant was detected in the region of aa 280-290 of the Е1 protein which was typical only for HCV 2a/2c genotype. A broad variation in the boundaries for the most epitopes suggests a high variability of the Е1 and Е2 viral proteins; however, a similar repertoire of antibodies induced by different HCV genotypes indicates to an opportunity of designing a new generation of cross-reactive HCV vaccines based on mapping of the E1 and E2 antigenic regions.

  6. Effect of Heamolysis on Prostate-Specific Antigen

    OpenAIRE

    Sağlam, Hasan S.; Köse, Osman; Özdemir, Fatma; Adsan, Öztuğ

    2012-01-01

    Purpose. We have investigated the effect of haemolysis on free and total prostate-specific antigen (PSA) in daily clinical practice. Materials and Methods. Thirty-nine consecutive men were enrolled in this study. With an 18 gauge (G) needle 4 cc of blood samples were drawn from the right arm and 2 cc of it was expelled gently in a Vacutainer for regular PSA assay and the remaining was emptied into a second tube for complete haemolysis. Simultaneously 2 cc of more blood were taken with a 26 G ...

  7. Accurate radioimmunoassay of human growth hormone with separation on polyacrylamide gel electrophoresis of free antigen; antigen-anti-body complex and damaged labelled antigen: a study is performed on this last one for the purpose of obtaining long lasting labelled products

    International Nuclear Information System (INIS)

    Bartolini, P.; Assis, L.M.; Schwarz, I.; Macchione, M.; Pieroni, R.R.

    1977-01-01

    The intent of this work was the obtainement of a radioimmunoassay method, accurate and precise enough, to furnish a suitable way for determining Human Growth Hormone (HGH) in extracts or in physiological fluids, useful more for specific research purposes than for routinized clinical assays, and where the labelled products could be used as long as possible. Only one technique was found that could give an answer to these requirements, though under some aspects more laborious than others: Polyacrylamide Gel Electrophoresis (PAGE). This was used introducing some modifications to the original method of Davis, and it was possible, using tubes 11 cm long, to separate on the same gel, the free, the antibody bound, and the damaged labelled antigen. The method, being able to detect separately and independently these three components and to give a better control on the analytically dangerous 'damaged', furnished accurate and reproducible curves. An example of determination is the one on KABI-Crescormon, that compares the results obatined with the present technique to those presented by another laboratory. Thanks to this method the labelled antigen could be used up to one month of time. After this period a re-purification on Sephadex was introduced so that the same labelled product was profitable for two more months. Parallel to this work a study has been performed on the various components originating in this so called process of 'damaging', and a particular importance has also been given to a more precise knowledge of the amount of antigen, in terms of mass, present in an assay. (orig.) [de

  8. A large portion of meningococcal antigen typing system-negative meningococcal strains from spain is killed by sera from adolescents and infants immunized with 4CMenB.

    Science.gov (United States)

    Abad, R; Biolchi, A; Moschioni, M; Giuliani, M M; Pizza, M; Vázquez, J A

    2015-04-01

    A new vaccine (the 4CMenB 4-component protein vaccine [Bexsero], which includes PorA, factor H-binding protein [fHbp], neisserial heparin-binding antigen [NHBA], and Neisseria adhesin A [NadA]) against serogroup B meningococci has recently been approved for use in people older than age 2 months in Europe, Australia, and Canada. Preapproval clinical efficacy studies are not feasible for invasive meningococcal disease because its incidence is low/very low, and the serum bactericidal antibody (SBA) titer (or the human SBA [hSBA] titer when human complement is used in the assay) has been used as a surrogate marker of protection. However, the hSBA assay cannot be used on a large scale, and therefore, a meningococcal antigen typing system (MATS) was developed. MATS combines conventional PorA genotyping with an enzyme-linked immunosorbent assay (ELISA) that quantifies both the expression and the cross-reactivity of antigenic variants. The assay has been used to evaluate the potential of the 4CMenB meningococcal group B vaccine to cover group B strains in several countries. Some recent data suggest that MATS is a conservative predictor of strain coverage. We used pooled sera from adolescents and infants to test by the hSBA assay 10 meningococcal group B strains isolated in Spain that were negative for the 3 antigens (n = 9) or that had very low levels of the 3 antigens (n = 1) by MATS. We found that all strains were killed by sera from adolescents and that 5 of the 10 strains were also killed, although at a low titer, by sera from infants. Our data confirm that MATS underestimates vaccine coverage. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  9. A comparison of labelled antibody methods for the detection of virus antigens in cell monolayers

    International Nuclear Information System (INIS)

    Oram, J.D.; Crooks, A.J.

    1979-01-01

    A number of labelled antibody methods have been applied to the detection of Semliki Forest virus antigens after replication of the virus in monolayers of host cells in multi-well polystyrene plates. The importance of several reaction variables has been investigated and the sensitivity of the methods compared for different periods of virus replication. Direct assays with radio-labelled antibody (RLA) and indirect assays peroxidase-antiperoxidase complexes (PAP) were equally sensitive. Direct and indirect assays using enzyme-linked antibodies (ELA) were slightly less sensitive than the direct RLA and PAP methods but were more sensitive than the indirect RLA or fluorescent antibody (FLA) methods. Direct assays using ELA were more rapid and easier to perform than the other assay methods. (Auth.)

  10. Production of Toxocara cati TES-120 Recombinant Antigen and Comparison with its T. canis Homolog for Serodiagnosis of Toxocariasis

    Science.gov (United States)

    Zahabiun, Farzaneh; Sadjjadi, Seyed Mahmoud; Yunus, Muhammad Hafiznur; Rahumatullah, Anizah; Moghaddam, Mohammad Hosein Falaki; Saidin, Syazwan; Noordin, Rahmah

    2015-01-01

    Toxocariasis is a cosmopolitan zoonotic disease caused by the infective larvae of Toxocara canis and T. cati. Diagnosis in humans is usually based on clinical symptoms and serology. Immunoglobulin G (IgG)-enzyme-linked immunosorbent assay kits using T. canis excretory–secretory (TES) larval antigens are commonly used for serodiagnosis. Differences in the antigens of the two Toxocara species may influence the diagnostic sensitivity of the test. In this study, T. cati recombinant TES-120 (rTES-120) was cloned, expressed, and compared with its T. canis homolog in an IgG4-western blot. The diagnostic sensitivity and specificity of T. cati rTES-120 were 70% (33/47) and 100% (39/39), respectively. T. canis rTES-120 showed 57.4% sensitivity and 94.4% specificity. When the results of assays using rTES-120 of both species were considered, the diagnostic sensitivity was 76%. This study shows that using antigens from both Toxocara species may improve the serodiagnosis of toxocariasis. PMID:26033026

  11. Monoclonal antibody against a serotype antigen of Porphyromonas (Bacteroides) endodontalis and characteristics of the antigen.

    Science.gov (United States)

    Hanazawa, S; Sagiya, T; Amano, S; Nishikawa, H; Kitano, S

    1990-01-01

    Recent studies have demonstrated the presence of three serotypes (O1K1, O1K2, and O1K-) of Porphyromonas (Bacteroides) endodontalis. In the present study, a hybridoma cell line producing monoclonal antibody (BEE11) specific for serotype O1K1 of P. endodontalis was established. The specificity of the antibody was evaluated by enzyme-linked immunosorbent assay and immunoslot blot analysis. BEE11 antibody reacted with strains ATCC 35406, HG 400, and HG 421 of the bacterium. However, it did not react with HG 422 or HG 948. Also, the antibody did not react with any of the black-pigmented Bacteroides strains tested. Although the antibody reacted with total cell envelope and capsule materials, it did not do so with lipopolysaccharide. The antibody reacted with antigen material having a molecular mass of 110 kilodaltons (kDa), as judged from fractionation by Superose 12 prep gel chromatography. When the peak fraction from the Superose 12 column was subjected to sodium dodecyl sulfate-polyacrylamide gel electrophoresis and Western blot (immunoblot) analysis, the reactivity was detected as a single band at an apparent molecular mass of about 52 kDa. The antigen material purified partially by high-performance liquid chromatography was sensitive to trypsin, V8 protease, and heating to 80 degrees C but not to neuraminidase. Therefore, the present study shows that BEE11 antibody recognizes a serotype antigen of P. endodontalis which may be a dimer consisting of monomers having molecular masses of approximately 52 kDa and sensitivity to proteases and heat. Images PMID:2370106

  12. A polyethylene glycol radioimmunoprecipitation assay for human immunoglobulin G

    International Nuclear Information System (INIS)

    Waller, S.J.; Taylor, R.P.; Andrews, B.S.

    1979-01-01

    A polyethylene glycol (PEG) radioimmunoprecipitation assay for human IgG is described that is sufficiently sensitive to detect 0.5 ng of IgG. This model antibody-antigen system was also used to study the stoichiometries of PEG-precipitation complexes. The results suggest that the presence of PEG may affect the stoichiometry of the complexes which precipitate from solution. (Auth.)

  13. Increased serum anti-mycobacterial antibody titers in rheumatoid arthritis patients: Is there any specific antigenic target?

    International Nuclear Information System (INIS)

    Cetin, Emel S.; Aksoy, Ali M

    2007-01-01

    Objective was to investigate the presence of immunoreactivity against mycobacterial antigens in the sera of patients with rheumatoid arthritis (Ra) and to detect the target of the immune reaction. This study was carried out on 60 patients with RA, and 25 patients with no joint diseases in the laboratory of Clinical Microbiology Department of Ankara University Medical Faculty, Ankara, Turkey between July 2003 to January 2004. Secreted and cellular antigens of Mycobacterium tuberculosis (M. tuberculosis) H37Rv and Mycobacterium bovis (M. bovis) were isolated and purified by high performance liquid chromatography to antigenic fractions. The immunoreactivity of patient and control sera against these antigens were determined by enzyme-linked immunosorbent assay (ELISA). Immunoreactivity against mycobacterial antigens in RA patients were significantly higher than controls. Significant difference between patients and controls has been determined with M. bovis Bacillus Calmette Guerin (BCG) culture fluid and sonicate antigens, but not with M. tuberculosis H37Rv. This suggests that the antigen triggering immune response in patients with RA may belong to or mainly expressed on M. bovis BCG. The ELISA results showed significant difference between RA patients and controls with all antigenic fractions. Presence of increased immunoreactivity against mycobacterial antigens in the sera of patients with RA was detected. When statistical analysis was considered, we cannot put forward any antigenic fraction alone as the one responsible for the increased reactivity. (author)

  14. Validation of a KHV antibody enzyme-linked immunosorbent assay (ELISA).

    Science.gov (United States)

    Bergmann, S M; Wang, Q; Zeng, W; Li, Y; Wang, Y; Matras, M; Reichert, M; Fichtner, D; Lenk, M; Morin, T; Olesen, N J; Skall, H F; Lee, P-Y; Zheng, S; Monaghan, S; Reiche, S; Fuchs, W; Kotler, M; Way, K; Bräuer, G; Böttcher, K; Kappe, A; Kielpinska, J

    2017-11-01

    Koi herpesvirus (KHV) causes KHV disease (KHVD). The virus is highly contagious in carp or koi and can induce a high mortality. Latency and, in some cases, a lack of signs presents a challenge for virus detection. Appropriate immunological detection methods for anti-KHV antibodies have not yet been fully validated for KHV. Therefore, it was developed and validated an enzyme-linked immunosorbent assay (ELISA) to detect KHV antibodies. The assay was optimized with respect to plates, buffers, antigens and assay conditions. It demonstrated high diagnostic and analytical sensitivity and specificity and was particularly useful at the pond or farm levels. Considering the scale of the carp and koi industry worldwide, this assay represents an important practical tool for the indirect detection of KHV, also in the absence of clinical signs. © 2017 John Wiley & Sons Ltd.

  15. Cell membrane antigen-antibody complex dissociation by the widely used glycine-HCL method: an unreliable procedure for studying antibody internalization.

    Science.gov (United States)

    Tsaltas, G; Ford, C H

    1993-02-01

    Methods following the process of binding and internalization of antibodies to cell surface antigens have often employed low pH isoosmolar buffers in order to dissociate surface antigen-antibody complexes. One of the most widely used buffers is a 0.05 M glycine-HCL buffer pH 2.8. Since the efficacy of action of this buffer was critical to a series of internalization experiments employing monoclonal antibodies (Mabs) to carcinoembryonic antigen (CEA) expressing cancer cell lines in this laboratory, we tested its performance in a number of different assays. Our results indicate that this buffer only partially dissociates antigen-antibody bonds and therefore can introduce major inaccuracies in internalization experiments.

  16. Screening for epitope specificity directly on culture supernatants in the early phase of monoclonal antibody production by an ELISA with biotin-labeled antigen

    DEFF Research Database (Denmark)

    Andersen, Ditte C; Jensen, Charlotte H; Gregersen, Annemette

    2004-01-01

    This report describes an assay for comparison of epitope specificity in groups of monoclonal antibodies against a given antigen. The only prerequisite is the biotin-labeled antigen. One of the monoclonal antibodies is captured onto a plastic surface via a rabbit anti-mouse Ig, and the other...... preincubated with biotinylated antigen. When the two antibodies react with the same epitope subsequent binding of the biotin-labeled antigen is abolished (inhibition). In the cases where no inhibition was observed, the two antibodies were considered to react with distinct, independent epitopes. The obvious...

  17. Definition of a virulence-related antigen of Neisseria gonorrhoeae with monoclonal antibodies and lectins.

    Science.gov (United States)

    Demarco de Hormaeche, R; Bundell, C; Chong, H; Taylor, D W; Wildy, P

    1986-03-01

    Variants of one strain of Neisseria gonorrhoeae, grown in vivo or in vitro, that have been previously shown to differ in infectivity, serum resistance, and capsule production were compared with use of monoclonal antibodies and lectins. Monoclonal antibodies to virulent gonococci recognized an antigenic site of the lipopolysaccharide (LPS) produced in large amounts by gonococci grown in vivo but present only in a small proportion of in vitro-grown gonococci. This antigen (C-LPS) was found in all 85 different gonococcal isolates studied but not among nonpathogenic neisseriae. It was shared by group B and C meningococci but not by groups A and D. Enzyme-linked immunosorbent assay and Western blot analysis showed that N-acetylglucosamine and N-acetylgalactosamine form part of the epitope. The C-LPS antigen was shown by immunofluorescence to be present on the surface of the gonococci and also free as slime. This antigen appears to confer resistance to killing by normal sera.

  18. Treatment of Schistosoma mansoni with miltefosine in vitro enhances serological recognition of defined worm surface antigens.

    Directory of Open Access Journals (Sweden)

    Marwa H El-Faham

    2017-08-01

    Full Text Available Miltefosine, an anti-cancer drug that has been successfully repositioned for treatment of Leishmania infections, has recently also shown promising effects against Schistosoma spp targeting all life cycle stages of the parasite. The current study examined the effect of treating Schistosoma mansoni adult worms with miltefosine on exposure of worm surface antigens in vitro.In an indirect immunofluorescence assay, rabbit anti-S.mansoni adult worm homogenate and anti-S. mansoni infection antisera gave strong immunofluorescence of the S. mansoni adult worm surface after treatment with miltefosine, the latter antiserum having previously been shown to synergistically enhance the schistosomicidal activity of praziquantel. Rabbit antibodies that recognised surface antigens exposed on miltefosine-treated worms were recovered by elution off the worm surface in low pH buffer and were used in a western immunoblotting assay to identify antigenic targets in a homogenate extract of adult worms (SmWH. Four proteins reacting with the antibodies in immunoblots were purified and proteomic analysis (MS/MS combined with specific immunoblotting indicated they were the S. mansoni proteins: fructose-1,6 bisphosphate aldolase (SmFBPA, Sm22.6, alkaline phosphatase and malate dehydrogenase. These antibodies were also found to bind to the surface of 3-hour schistosomula and induce immune agglutination of the parasites, suggesting they may have a role in immune protection.This study reveals a novel mode of action of miltefosine as an anti-schistosome agent. The immune-dependent hypothesis we investigated has previously been lent credence with praziquantel (PZQ, whereby treatment unmasks parasite surface antigens not normally exposed to the host during infection. Antigens involved in this molecular mechanism could have potential as intervention targets and antibodies against these antigens may act to increase the drug's anti-parasite efficacy and be involved in the development

  19. Quantitative and multiplexed detection for blood typing based on quantum dot-magnetic bead assay.

    Science.gov (United States)

    Xu, Ting; Zhang, Qiang; Fan, Ya-Han; Li, Ru-Qing; Lu, Hua; Zhao, Shu-Ming; Jiang, Tian-Lun

    2017-01-01

    Accurate and reliable blood grouping is essential for safe blood transfusion. However, conventional methods are qualitative and use only single-antigen detection. We overcame these limitations by developing a simple, quantitative, and multiplexed detection method for blood grouping using quantum dots (QDs) and magnetic beads. In the QD fluorescence assay (QFA), blood group A and B antigens were quantified using QD labeling and magnetic beads, and the blood groups were identified according to the R value (the value was calculated with the fluorescence intensity from dual QD labeling) of A and B antigens. The optimized performance of QFA was established by blood typing 791 clinical samples. Quantitative and multiplexed detection for blood group antigens can be completed within 35 min with more than 10 5 red blood cells. When conditions are optimized, the assay performance is satisfactory for weak samples. The coefficients of variation between and within days were less than 10% and the reproducibility was good. The ABO blood groups of 791 clinical samples were identified by QFA, and the accuracy obtained was 100% compared with the tube test. Receiver-operating characteristic curves revealed that the QFA has high sensitivity and specificity toward clinical samples, and the cutoff points of the R value of A and B antigens were 1.483 and 1.576, respectively. In this study, we reported a novel quantitative and multiplexed method for the identification of ABO blood groups and presented an effective alternative for quantitative blood typing. This method can be used as an effective tool to improve blood typing and further guarantee clinical transfusion safety.

  20. A ''reverse'' solid-phase radio-immuno-assay for IgM-antibodies to hepatitis A virus

    International Nuclear Information System (INIS)

    Meurman, O.H.; Matter, L.; Krishna, R.V.; Krech, U.H.

    1981-01-01

    A ''reverse'' solid-phase radio-immuno-assay for IgM antibodies to hepatitis A virus (HAV) was developed. Anti-human IgM immunoglobulins were bound on the wells of polyvinylchloride microtiter plates. Serum specimens were incubated in the anti-human IgM coated wells and bound IgM antibodies were then assayed for antigen specificity by subsequent incubations with HAV antigen and 125 I-labelled human anti-HAV IgG. The test showed a high sensitivity and specificity for anti-HAV IgM antibodies. No false-positive reactions were observed either in the sera from patients with hepatobiliary disorders other than HAV infection or in the sera containing both rheumatoid factor and anti-HAV IgG antibodies. In acute HAV infections specific IgM antibodies were present already in the first specimens taken within a few days after the onset of jaundice. The persistence of the IgM antibodies was from 4 to 6 months. IgM antibody titers up to 1,000,000 were observed in the acute phase of HAV infection. In routine diagnostic work the titration of the sera was not necessary, since a reliable qualitative result was obtained by testing the sera in a single dilution of 1:100. A similar ''reverse'' immuno-assay principle may be adaptable for the diagnostic determination of IgM antibodies to different viral and microbial antigens. (author)

  1. Antigenic variation of H1N1, H1N2 and H3N2 swine influenza viruses in Japan and Vietnam.

    Science.gov (United States)

    Takemae, Nobuhiro; Nguyen, Tung; Ngo, Long Thanh; Hiromoto, Yasuaki; Uchida, Yuko; Pham, Vu Phong; Kageyama, Tsutomu; Kasuo, Shizuko; Shimada, Shinichi; Yamashita, Yasutaka; Goto, Kaoru; Kubo, Hideyuki; Le, Vu Tri; Van Vo, Hung; Do, Hoa Thi; Nguyen, Dang Hoang; Hayashi, Tsuyoshi; Matsuu, Aya; Saito, Takehiko

    2013-04-01

    The antigenicity of the influenza A virus hemagglutinin is responsible for vaccine efficacy in protecting pigs against swine influenza virus (SIV) infection. However, the antigenicity of SIV strains currently circulating in Japan and Vietnam has not been well characterized. We examined the antigenicity of classical H1 SIVs, pandemic A(H1N1)2009 (A(H1N1)pdm09) viruses, and seasonal human-lineage SIVs isolated in Japan and Vietnam. A hemagglutination inhibition (HI) assay was used to determine antigenic differences that differentiate the recent Japanese H1N2 and H3N2 SIVs from the H1N1 and H3N2 domestic vaccine strains. Minor antigenic variation between pig A(H1N1)pdm09 viruses was evident by HI assay using 13 mAbs raised against homologous virus. A Vietnamese H1N2 SIV, whose H1 gene originated from a human strain in the mid-2000s, reacted poorly with post-infection ferret serum against human vaccine strains from 2000-2010. These results provide useful information for selection of optimal strains for SIV vaccine production.

  2. Identification and characterization of a novel protective antigen, Enolase of Streptococcus suis serotype 2.

    Science.gov (United States)

    Zhang, Anding; Chen, Bo; Mu, Xiaofeng; Li, Ran; Zheng, Pei; Zhao, Yaxin; Chen, Huanchun; Jin, Meilin

    2009-02-25

    Streptococcus suis serotype 2 (SS2) is a porcine and human pathogen with adhesive and invasive properties. The absence of suitable vaccine or virulent marker can be the bottleneck to control SS2 infection. In the present study, a novel immunogenic Enolase identified in the previous study was inducibly overexpressed in Escherichia coli, and the purified recombinant protein could elicit a significant humoral antibody response and confer efficient immunity against challenge with lethal dose of SS2 or SS7 infection in mouse model. The roles Enolase plays in pathogenicity of SS2 were also explored as reasons for which Enolase could be a protective antigen. The Enolase was an in vivo-induced antigen confirmed by the real-time PCR and could adhere to the Hep-2 cells by the indirect immunofluorescent assay and the inhibition assay. These suggested that Enolase could play important roles in pathogenicity and may serve as a novel vaccine candidate against SS2 infection.

  3. Shared and non-shared antigens from three different extracts of the metacestode of Echinococcus granulosus

    Directory of Open Access Journals (Sweden)

    David Carmena

    2005-12-01

    Full Text Available Hydatid cyst fluid (HCF, somatic antigens (S-Ag and excretory-secretory products (ES-Ag of Echinococcus granulosus protoscoleces are used as the main antigenic sources for immunodiagnosis of human and dog echinococcosis. In order to determine their non-shared as well as their shared antigenic components, these extracts were studied by ELISA-inhibition and immunoblot-inhibition. Assays were carried out using homologous rabbit polyclonal antisera, human sera from individuals with surgically confirmed hydatidosis, and sera from dogs naturally infected with E. granulosus. High levels of cross-reactivity were observed for all antigenic extracts, but especially for ES-Ag and S-Ag. Canine antibodies evidenced lesser avidity for their specific antigens than antibodies from human origin. The major antigenic components shared by HCF, S-Ag, and ES-Ag have apparent molecular masses of 4-6, 20-24, 52, 80, and 100-104 kDa, including doublets of 41/45, 54/57, and 65/68 kDa. Non-shared polypeptides of each antigenic extract of E. granulosus were identified, having apparent masses of 108 and 78 kDa for HCF, of 124, 94, 83, and 75 kDa for S-Ag, and of 89, 66, 42, 39, 37, and 35 kDa for ES-Ag.

  4. Asymptomatic cryptococcal antigen prevalence detected by lateral flow assay in hospitalised HIV-infected patients in São Paulo, Brazil.

    Science.gov (United States)

    Vidal, José E; Toniolo, Carolina; Paulino, Adriana; Colombo, Arnaldo; Dos Anjos Martins, Marilena; da Silva Meira, Cristina; Pereira-Chioccola, Vera Lucia; Figueiredo-Mello, Claudia; Barros, Tiago; Duarte, Jequelie; Fonseca, Fernanda; Alves Cunha, Mirella; Mendes, Clara; Ribero, Taiana; Dos Santos Lazera, Marcia; Rajasingham, Radha; Boulware, David R

    2016-12-01

    To determine the prevalence of asymptomatic cryptococcal antigen (CRAG) using lateral flow assay (LFA) in hospitalised HIV-infected patients with CD4 counts 18 years old without prior cryptococcal meningitis, without clinical suspicion of cryptococcal meningitis, regardless of antiretroviral (ART) status, and with CD4 counts <200 cells/μl. Serum CRAG was tested by LFA in all patients, and whole blood CRAG was tested by LFA in positive cases. We enrolled 163 participants of whom 61% were men. The duration of HIV diagnosis was a median of 8 (range, 1-29) years. 26% were antiretroviral (ART)-naïve, and 74% were ART-experienced. The median CD4 cell count was 25 (range, 1-192) cells/μl. Five patients (3.1%; 95%CI, 1.0-7.0%) were asymptomatic CRAG-positive. Positive results cases were cross-verified by performing LFA in whole blood. 3.1% of HIV-infected inpatients with CD4 <200 cells/μl without symptomatic meningitis had cryptococcal antigenemia in São Paulo, suggesting that routine CRAG screening may be beneficial in similar settings in South America. Our study reveals another targeted population for CRAG screening: hospitalised HIV-infected patients with CD4 <200 cells/μl, regardless of ART status. Whole blood CRAG LFA screening seems to be a simple strategy to prevention of symptomatic meningitis. © 2016 John Wiley & Sons Ltd.

  5. An enzyme-linked immunosorbent assay for bromodeoxyuridine incorporation using fixed microcultures

    International Nuclear Information System (INIS)

    Muir, D.; Varon, S.; Manthorpe, M.

    1990-01-01

    We report a quantitative method by which a single microculture can be examined for cell morphology; cell number; DNA synthesis; and expression of cell antigens. This method first involves measuring by enzyme-linked immunosorbent assay (ELISA) the total bromodeoxyuridine (BrdU) incorporation into DNA by monolayer microcultures. The BrdU-ELISA measurement was followed by simultaneous immunostaining for BrdU-positive nuclei and for a cytoplasmic antigen. The method was applied to the measurement of mitogen-induced proliferation of rat sciatic nerve Schwann cell and cerebral astroglia microcultures. The ELISA measurement of BrdU incorporation compares favorably with measurements of tritiated thymidine incorporation and offers the additional advantages that the same microculture can subsequently be examined for cell number, for cell morphology, and for the percentage of cells having BrdU-labeled nuclei and other antigens

  6. An enzyme-linked immunosorbent assay for bromodeoxyuridine incorporation using fixed microcultures

    Energy Technology Data Exchange (ETDEWEB)

    Muir, D.; Varon, S.; Manthorpe, M. (Univ. of California, San Diego, La Jolla (USA))

    1990-03-01

    We report a quantitative method by which a single microculture can be examined for cell morphology; cell number; DNA synthesis; and expression of cell antigens. This method first involves measuring by enzyme-linked immunosorbent assay (ELISA) the total bromodeoxyuridine (BrdU) incorporation into DNA by monolayer microcultures. The BrdU-ELISA measurement was followed by simultaneous immunostaining for BrdU-positive nuclei and for a cytoplasmic antigen. The method was applied to the measurement of mitogen-induced proliferation of rat sciatic nerve Schwann cell and cerebral astroglia microcultures. The ELISA measurement of BrdU incorporation compares favorably with measurements of tritiated thymidine incorporation and offers the additional advantages that the same microculture can subsequently be examined for cell number, for cell morphology, and for the percentage of cells having BrdU-labeled nuclei and other antigens.

  7. Evaluation of ascitic soluble human leukocyte antigen-G for distinguishing malignant ascites from benign ascites.

    Science.gov (United States)

    Sun, Juan; Chang, Yan-Xiang; Niu, Chun-Yan

    2017-11-01

    The overexpression of soluble human leukocyte antigen-G is associated with malignant tumours. The purpose of our study was to detect soluble human leukocyte antigen-G concentrations in ascites and to evaluate the value of ascitic soluble human leukocyte antigen-G for the diagnosis of malignant ascites. Enzyme-linked immunosorbent assay was used to detect soluble human leukocyte antigen-G levels in 64 patients with malignant ascites and 30 patients with benign ascites. Receiver operating characteristic curves were used to evaluate the diagnostic efficacy of ascitic soluble human leukocyte antigen-G for the detection of malignant ascites. Ascitic soluble human leukocyte antigen-G levels were significantly higher in the malignant ascites group than in the benign ascites group (20.718 ± 3.215 versus 12.467 ± 3.678 µg/L, t = 7.425, p human leukocyte antigen-G was 0.957 (95% confidence interval, 0.872-0.992). At a cut-off value of 19.60 µg/L, the sensitivity and specificity of ascitic soluble human leukocyte antigen-G were 87.5% (95% confidence interval, 71.0%-96.5%) and 100% (95% confidence interval, 88.4%-100%), respectively. With respect to area under the receiver operating characteristic curve, sensitivity and specificity, ascitic carcinoembryonic antigen (0.810, 68.75% and 83.33%, respectively) and carbohydrate antigen 19-9 (0.710, 65.63% and 70%, respectively) significantly differed (all p human leukocyte antigen-G was 75%, which was higher than the corresponding rates for ascitic carcinoembryonic antigen (31.25%) and carbohydrate antigen 19-9 (6.25%; both p human leukocyte antigen-G exhibited good performance for diagnosing malignant ascites, and particularly those that were cytology-negative and biopsy-positive.

  8. Antigenicity analysis of Vibrio harveyi TS-628 strain

    Institute of Scientific and Technical Information of China (English)

    QIN Yingxue; WANG Jun; WANG Shifeng; YAN Qingpi

    2007-01-01

    Vibrio harveyi,the major causative agent of vibriosis,affects a diverse range of marine cultured organisms over a wide geographical area.However,reports about screening the effective antigen and research on vaccines of V.harveyi are scarce.Flagellin,lipopolysaccharide (LPS) and outer membrane proteins (OMP) are major immunogenic antigens in many Gram-negative bacteria.In this study,the flagellin,OMP and LPS of the V.harveyi TS-628 strain isolated from infected groupers were extracted and Western blot analysis was used to detect the antigenicity of these extractions.Results of the Western blot assay reveal that there are four positive flagellin bands:35 kDa,38 kDa,43 kDa,and 52 kDa,of which the 43 kDa and 52 kDa bands displayed the strongest positive reaction.There are five positive OMP bands about 35 kDa,38 kDa,43 kDa,47 kDa,and 52 kDa,of which the 43 kDa appeared to have the strongest positive reaction although the other four proteins also displayed strong reactions.However,LPS is Western blot-negative.These results indicate that the 43 kDa and 52 kDa flagellin and OMP of size 43 kDa,52 kDa can be candidates for developing vaccines against V.harveyi.

  9. Antigenic Characterization of H3 Subtypes of Avian Influenza A Viruses from North America.

    Science.gov (United States)

    Bailey, Elizabeth; Long, Li-Ping; Zhao, Nan; Hall, Jeffrey S; Baroch, John A; Nolting, Jacqueline; Senter, Lucy; Cunningham, Frederick L; Pharr, G Todd; Hanson, Larry; Slemons, Richard; DeLiberto, Thomas J; Wan, Xiu-Feng

    2016-05-01

    Besides humans, H3 subtypes of influenza A viruses (IAVs) can infect various animal hosts, including avian, swine, equine, canine, and sea mammal species. These H3 viruses are both antigenically and genetically diverse. Here, we characterized the antigenic diversity of contemporary H3 avian IAVs recovered from migratory birds in North America. Hemagglutination inhibition (HI) assays were performed on 37 H3 isolates of avian IAVs recovered from 2007 to 2011 using generated reference chicken sera. These isolates were recovered from samples taken in the Atlantic, Mississippi, Central, and Pacific waterfowl migration flyways. Antisera to all the tested H3 isolates cross-reacted with each other and, to a lesser extent, with those to H3 canine and H3 equine IAVs. Antigenic cartography showed that the largest antigenic distance among the 37 avian IAVs is about four units, and each unit corresponds to a 2 log 2 difference in the HI titer. However, none of the tested H3 IAVs cross-reacted with ferret sera derived from contemporary swine and human IAVs. Our results showed that the H3 avian IAVs we tested lacked significant antigenic diversity, and these viruses were antigenically different from those circulating in swine and human populations. This suggests that H3 avian IAVs in North American waterfowl are antigenically relatively stable.

  10. Hepatitis B surface antigen (HBsAg) expression in plant cell culture: Kinetics of antigen accumulation in batch culture and its intracellular form.

    Science.gov (United States)

    Smith, Mark L; Mason, Hugh S; Shuler, Michael L

    2002-12-30

    The production of edible vaccines in transgenic plants and plant cell culture may be improved through a better understanding of antigen processing and assembly. The hepatitis B surface antigen (HBsAg) was chosen for study because it undergoes substantial and complex post-translational modifications, which are necessary for its immunogenicity. This antigen was expressed in soybean (Glycine max L. Merr. cv Williams 82) and tobacco NT1 (Nicotiana tabacum L.) cell suspension cultures, and HBsAg production in batch culture was characterized. The plant-derived antigen consisted predominantly of disulfide cross-linked HBsAg protein (p24(s)) dimers, which were all membrane associated. Similar to yeast, the plant-expressed HBsAg was retained intracellularly. The maximal HBsAg titers were obtained with soybean suspension cultures (20-22 mg/L) with titers in tobacco cultures being approximately 10-fold lower. For soybean cells, electron microscopy and immunolocalization demonstrated that all the HBsAg was localized to the endoplasmic reticulum (ER) and provoked dilation and proliferation of the ER network. Sucrose gradient analysis of crude extracts showed that HBsAg had a complex size distribution uncharacteristic of the antigen's normal structure of uniform 22-nm virus-like particles. The extent of authentic epitope formation was assessed by comparing total p24(s) synthesized to that reactive by polyclonal and monoclonal immunoassays. Depending on culture age, between 40% and 100% of total p24(s) was polyclonal antibody reactive whereas between 6% and 37% was recognized by a commercial monoclonal antibody assay. Possible strategies to increase HBsAg production and improve post-translational processing are discussed. Copyright 2002 Wiley Periodicals, Inc.

  11. Chloroplast-Derived Vaccine Antigens and Biopharmaceuticals: Expression, Folding, Assembly and Functionality

    Science.gov (United States)

    Chebolu, S.; Daniell, H.

    2009-01-01

    Chloroplast genetic engineering offers several advantages, including high levels of transgene expression, transgene containment via maternal inheritance, and multi-gene expression in a single transformation event. Oral delivery is facilitated by hyperexpression of vaccine antigens against cholera, tetanus, anthrax, plague, or canine parvovirus (4%–31% of total soluble protein, TSP) in transgenic chloroplasts (leaves) or non-green plastids (carrots, tomato) as well as the availability of antibiotic free selectable markers or the ability to excise selectable marker genes. Hyperexpression of several therapeutic proteins, including human serum albumin (11.1% TSP), somatotropin (7% TSP), interferon-alpha (19% TSP), interferon-gamma (6% TSP), and antimicrobial peptide (21.5% TSP), facilitates efficient and economic purification. Also, the presence of chaperones and enzymes in chloroplasts facilitates assembly of complex multisubunit proteins and correct folding of human blood proteins with proper disulfide bonds. Functionality of chloroplast-derived vaccine antigens and therapeutic proteins has been demonstrated by several assays, including the macrophage lysis assay, GM1-ganglioside binding assay, protection of HeLA cells or human lung carcinoma cells against encephalomyocarditis virus, systemic immune response, protection against pathogen challenge, and growth or inhibition of cell cultures. Purification of human proinsulin has been achieved using novel purification strategies (inverse temperature transition property) that do not require expensive column chromatography techniques. Thus, transgenic chloroplasts are ideal bioreactors for production of functional human and animal therapeutic proteins in an environmentally friendly manner. PMID:19401820

  12. Glycan bioengineering in immunogen design for tumor T antigen immunotargeting

    DEFF Research Database (Denmark)

    Sendra, Victor G; Zlocowski, Natacha; Ditamo, Yanina

    2009-01-01

    MM2 energy function showed that pentalysine (Lys5) linker and benzyl (Bzl) residue enhance TFD rigidity of the glycosidic bond. Antibodies raised against BzlalphaTFD-Lys5 immunogen recognize tumor T antigen. Competitive assays confirm that TFD-related structures are the main glycan epitope...... to the bioengineered glycoconjugate inhibited CT26 tumor cell proliferation and reduced tumor growth in an in vivo mouse model. These results show that TFD bioengineering is a useful immunogenic strategy with potential application in cancer therapy. The same approach can be extended to other glycan immunogens......Bioengineering of Galbeta3GalNAcalpha, known as Thomsen-Friedenreich disaccharide (TFD), is studied to promote glycan immunogenicity and immunotargeting to tumor T antigen (Galbeta3GalNAcalpha-O-Ser/Thr). Theoretical studies on disaccharide conformations by energy minimization of structures using...

  13. Shedding of CD9 antigen into cerebrospinal fluid by acute lymphoblastic leukemia cells.

    Science.gov (United States)

    Komada, Y; Ochiai, H; Shimizu, K; Azuma, E; Kamiya, H; Sakurai, M

    1990-07-01

    The accurate identification of small numbers of leukemic cells in the cerebrospinal fluid (CSF) presents a diagnostic problem in the treatment of acute lymphoblastic leukemia (ALL). We demonstrated that soluble CD9 antigen was shed into CSF obtained from children with ALL, using enzyme-linked immunosorbent assay (ELISA), which used the activity of CD9 antigen to bind the Ricinus communis agglutinin (RCA1) and a monoclonal antibody, SJ-9A4, simultaneously. Using RCA1/SJ-9A4 ELISA, CD9 antigen was detectable in CSF but not in plasma from 12 cases of CD9+ ALL in central nervous system (CNS) relapse. However, CD9 antigen was not released into CSF from 11 cases of CD9- ALL with CNS involvement, 136 cases of CD9+ ALL in complete remission (CR), 29 cases of CD9- ALL in CR, or 21 cases of aseptic meningitis. Interestingly, the levels of CD9 antigen were elevated in CSF from 7 of 10 CD9+ ALL patients without cytologically proven CNS involvement at diagnosis, with subsequent return to undetectable levels after initial induction chemotherapy was begun. In addition, sequential analysis of CSF from a 5-year-old boy with CD9+ ALL in CNS relapse showed that levels of CD9 antigen correlated well with the number of leukemic cells in CSF. Serial quantitative analysis of CD9 antigen in CSF could be useful to detect the proliferation of residual leukemic cells before the clinical manifestation.

  14. Rapid, Sensitive, Enzyme-Immunodotting Assay for Detecting Cow Milk Adulteration in Sheep Milk: A Modern Laboratory Project

    Science.gov (United States)

    Inda, Luis A.; Razquín, Pedro; Lampreave, Fermín; Alava, María A.; Calvo, Miguel

    1998-12-01

    Specificity, sensitivity, and experimental simplicity make the immunoenzymatic assay suitable for a variety of laboratories dedicated to diverse activities such as research, quality control in food analysis, or clinical biochemistry. In these assays, the antibody that specifically recognizes the antigen is covalently attached to an enzyme. Once the antigen-antibody immunocomplex is formed, the enzymatic reaction gives a colored product that allows the detection of the initial antigen. The aim of this work was the design of a new laboratory project appropriate for use in courses of biochemistry, immunochemistry, or analytical chemistry. The assay described here detects the presence of cow milk in milk of other species. The main application is the detection of cow milk in sheep milk and cheese. Specific proteins, immunoglobulins (IgG) of the fraudulent bovine milk, are specifically recognized and retained by antibodies immobilized on a membrane. The binding of a second antibody covalently attached to horseradish peroxidase (HRP) allows the development of a visible signal. Thus, students can rapidly detect milk adulterations using a specific, sensitive, and safe experimental approach. The experiment allows students to apply their theoretical knowledge, resulting in a stimulating experience of solving a real problem during a 4-hour laboratory period.

  15. A Model System for Concurrent Detection of Antigen and Antibody Based on Immunological Fluorescent Method

    Directory of Open Access Journals (Sweden)

    Yuan-Cheng Cao

    2015-01-01

    Full Text Available This paper describes a combined antigen/antibody immunoassay implemented in a 96-well plate using fluorescent spectroscopic method. First, goat anti-human IgG was used to capture human IgG (model antigen; goat anti-human IgG (Cy3 or FITC was used to detect the model antigen; a saturating level of model antigen was then added followed by unlabelled goat anti-human IgG (model antibody; finally, Cy3 labelled rabbit anti-goat IgG was used to detect the model antibody. Two approaches were applied to the concomitant assay to analyze the feasibility. The first approach applied FITC and Cy3 when both targets were present at the same time, resulting in 50 ng/mL of the antibody detection limit and 10 ng/mL of antigen detection limit in the quantitative measurements of target concentration, taking the consideration of FRET efficiency of 68% between donor and acceptor. The sequential approach tended to lower the signal/noise (S/N ratio and the detection of the model antigen (lower than 1 ng/mL had better sensitivity than the model antibody (lower than 50 ng/mL. This combined antigen/antibody method might be useful for combined detection of antigens and antibodies. It will be helpful to screen for both antigen and antibody particularly in the situations of the multiserotype and high-frequency mutant virus infections.

  16. Porcine reproductive and respiratory syndrome virus: antigenic and molecular diversity of British isolates and implications for diagnosis.

    Science.gov (United States)

    Frossard, Jean-Pierre; Fearnley, Catherine; Naidu, Brindha; Errington, Jane; Westcott, David G; Drew, Trevor W

    2012-08-17

    Porcine reproductive and respiratory syndrome (PRRS) is an endemic disease of pigs, caused by PRRS virus, a member of the Arteriviridae family. First seen in Britain in 1991, the disease continues to be a significant economic and welfare problem for pig producers. To date, only PRRSV genotype 1 has been found in Britain. At the genetic level, a considerable increase has been reported in the diversity of PRRS viruses isolated in Britain between 2003 and 2007, versus the early 1990 s. In this study, the diversity has been shown to extend to the antigenic level too, with potential consequences for diagnostic methods. Antigenic diversity was assessed using a panel of twelve monoclonal antibodies, only one of which reacted with all isolates tested. Nine diverse viruses were compared as potential antigens in immunoperoxidase monolayer assays, where each one produced quite different results for a common panel of sera. As a single virus is used in each diagnostic assay, results must therefore be interpreted cautiously. For a real-time RT-PCR assay, published oligonucleotide primer and probe sequences were evaluated against available genetic sequences of British and European viruses, and were re-designed where considerable mismatches were found. The multiplex assay incorporating these modified primers to detect genotype 1 and 2 PRRS viruses was then validated for use with diagnostic sera and tissues. As the increasing degree of diversity exhibited by British strains is mirrored in other countries, PRRSV will continue to provide an ongoing challenge to diagnosis at a global, as well as national level. Crown Copyright © 2012. Published by Elsevier B.V. All rights reserved.

  17. Screening hybridomas for anabolic androgenic steroids by steroid analog antigen microarray.

    Science.gov (United States)

    Du, Hongwu; Chen, Guangyu; Bian, Yongzhong; Xing, Cenzan; Ding, Xue; Zhu, Mengliang; Xun, Yiping; Chen, Peng; Zhou, Yabin; Li, Shaoxu

    2015-01-01

    Currently, dozens of anabolic androgenic steroids (AAS) are forbidden in the World Anti-Doping Agency Prohibited List, however, despite extensive investigation, there are still lots of AAS without corresponding monoclonal antibodies. A steroid analog antigen microarray made up of ten AAS was fabricated to screen the hybridoma and it was found an original unsuccessful clone turned out to be a candidate anti-boldenone antibody, without any cross-reactions with endogenous AAS or 44 different AAS standard reference materials tested. Our findings suggested that steroid analog antigen microarray could be a promising tool to screen and characterize new applications of antibodies for structure analogs, and this also exhibits the potential to fast identify effective epitopes of hybridomas in a single assay.

  18. [Examination about utility of a Streptococcus pneumoniae capsular antigen swiftness search kit urine in a pneumonia patient].

    Science.gov (United States)

    Hashikita, Giichi; Yamaguti, Toshiyuki; Tachi, Yoshimi; Kishi, Etsuko; Kawamura, Toru; Takahashi, Shun; Arai, Yukie; Koyama, Sachie; Huruhata, Toshihumi; Itabashi, Akira; Oka, Yoko; Yamazaki, Tsutomu; Maesaki, Sigefumi

    2005-01-01

    We investigated the usefullness of Binax NOW urine antigen test, an immunochromatographic assay that binds any soluble Streptococcus pneumoniae antigen (C polysaccharide) for the diagnosis of penumoniae form September 2003 to March 2005. We used 372 samples form the patinets with pneumoniae diagnosed for blood or sputum cultuter or gram-stained sputum smear. Out of 24 culture positive specimens, Binax NOW urine antigen test, showed positive in 18 (75%) specimens. The sensitivity of sputum and blood culture was 71.7% and 83.3%, respectively. Binax NOW urine antigen test was seemed false positives in 55 samples, false negatives in 6 samples. The specificity of Binax NOW urine antigen test was evaluated 84.1%. Overall agreement among tests was 83.6%. When compared to culture, false negative urine antigen may be the result of colonizing S. pneumoniae in sputum or pneumonia caused by an agent other than S. pneumoniae. CRP values for cases were both urine antigen and culture were positive ranged from 40 mg/dl to 10 mg/dl while urine antigen and culture negative cases were predominantly less than 10 mg/dl. Positive blood and pleural fluid culture cases were consistently associated with strongly positive urine antigen tests. Non-agreement between urine antigen, culture, and microscopy may be the result of specimen quality, labile nature of S. pneumoniae and antimicrobial therapy.

  19. Immunoradiometric assay of a novel proliferation marker: tumour polypeptide specific antigen in breast cancer management in north India

    International Nuclear Information System (INIS)

    Phanna-Hazra, P.; Sharma, U.; Gupta, K.K.; Bhatnagar, V.; Idnani, R.; Gangwar, P.K.; Hazra, D.K.

    2004-01-01

    Tissue Polypeptide Specific Antigen (TPS) is a novel tumour marker defined by the monoclonal antibody M3 ,discovered by Bjorklund,which is claimed to be a proliferation marker, and belonging to the cytokeratin 8-18 family. M3 defines this antigen in particular out of a group of Tissue Polypeptide antigens (TPA) charecterised by the same Swedish group and was claimed to be a pancarcinoma antigen reportedly being elevated in several different cancers in the European literature.Pancarcinoma markers are of interest in relation to cancer detection as well as for assessing therapy and prognosis.Pancarcinoma antigens are also of interest for radiobioconjugate immunotargetting both for diagnosis as well as for therapy. There were no reports on this marker in an Indian population and therefore this study was initiated at two institutions in Meerut and Agra, both in the northern state of Uttar Pradesh. In addition to 250 healthy controls, 288 cases of breast cancer were studied .In addituion benign disorders were studied: breast fibroadenosis 16, breast fibro adenoma 5, breast abscess 4. TPS levels were determined by an immunoradiometric assay. In controls all but 4 had values less than 80 Units/1,the upper normal level quoted by Bjorklund.The relationship of the serum levels of the markers to histological grade and anatomical stage of the tumour were studied. In addition several of the cases underwent therapy with chemotherapy /radiotherapy/surgery or combinations thereof. The response to treatment during follow up was categorized as Complete emission(CR),Partial Remission (PR)Stable Disease(SD), Progressive Disease(PD)and recurrence (R) by the respective clinicians using standard criteria. In the cancer subjects there was a close correlation of TPS elevation with anatomical stage. 10 cases belonged to stage 1 with TPS levels 176.1+-103.94 Units/L ,61 to stage II(TPS levels 206.45 +-168.23).,79 to stage Ilia (TPS 251.5+-168.53),83 to stage IIIB (TPS 537.35+- 691.71),and 55

  20. The Hamster Model for Identification of Specific Antigens of Taenia solium Tapeworms

    Science.gov (United States)

    Ochoa-Sánchez, Alicia; Jiménez, Lucía; Landa, Abraham

    2011-01-01

    Humans acquire taeniasis by ingesting pork meat infected with Taenia solium cysticerci, which are the only definitive hosts of the adult stage (tapeworm) and responsible for transmitting the human and porcine cysticercosis. Hence, detection of human tapeworm carriers is a key element in the development of viable strategies to control the disease. This paper presents the identification of specific antigens using sera from hamsters infected with T. solium tapeworms analyzed by western blot assay with crude extracts (CEs) and excretion-secretion antigens (E/S Ag) obtained from T. solium cysticerci and tapeworms and extracts from other helminthes as controls. The hamster sera infected with T. solium tapeworms recognized specific bands of 72, 48, 36, and 24 kDa, in percentages of 81, 81, 90, and 88%, respectively, using the T. solium tapeworms E/S Ag. The antigens recognized by these hamster sera could be candidates to improve diagnosis of human T. solium taeniasis. PMID:22253530

  1. The Hamster Model for Identification of Specific Antigens of Taenia solium Tapeworms

    Directory of Open Access Journals (Sweden)

    Alicia Ochoa-Sánchez

    2011-01-01

    Full Text Available Humans acquire taeniasis by ingesting pork meat infected with Taenia solium cysticerci, which are the only definitive hosts of the adult stage (tapeworm and responsible for transmitting the human and porcine cysticercosis. Hence, detection of human tapeworm carriers is a key element in the development of viable strategies to control the disease. This paper presents the identification of specific antigens using sera from hamsters infected with T. solium tapeworms analyzed by western blot assay with crude extracts (CEs and excretion-secretion antigens (E/S Ag obtained from T. solium cysticerci and tapeworms and extracts from other helminthes as controls. The hamster sera infected with T. solium tapeworms recognized specific bands of 72, 48, 36, and 24 kDa, in percentages of 81, 81, 90, and 88%, respectively, using the T. solium tapeworms E/S Ag. The antigens recognized by these hamster sera could be candidates to improve diagnosis of human T. solium taeniasis.

  2. The glycosphingolipid P₁ is an ovarian cancer-associated carbohydrate antigen involved in migration.

    Science.gov (United States)

    Jacob, F; Anugraham, M; Pochechueva, T; Tse, B W C; Alam, S; Guertler, R; Bovin, N V; Fedier, A; Hacker, N F; Huflejt, M E; Packer, N; Heinzelmann-Schwarz, V A

    2014-10-14

    The level of plasma-derived naturally circulating anti-glycan antibodies (AGA) to P1 trisaccharide has previously been shown to significantly discriminate between ovarian cancer patients and healthy women. Here we aim to identify the Ig class that causes this discrimination, to identify on cancer cells the corresponding P1 antigen recognised by circulating anti-P1 antibodies and to shed light into the possible function of this glycosphingolipid. An independent Australian cohort was assessed for the presence of anti-P1 IgG and IgM class antibodies using suspension array. Monoclonal and human derived anti-glycan antibodies were verified using three independent glycan-based immunoassays and flow cytometry-based inhibition assay. The P1 antigen was detected by LC-MS/MS and flow cytometry. FACS-sorted cell lines were studied on the cellular migration by colorimetric assay and real-time measurement using xCELLigence system. Here we show in a second independent cohort (n=155) that the discrimination of cancer patients is mediated by the IgM class of anti-P1 antibodies (P=0.0002). The presence of corresponding antigen P1 and structurally related epitopes in fresh tissue specimens and cultured cancer cells is demonstrated. We further link the antibody and antigen (P1) by showing that human naturally circulating and affinity-purified anti-P1 IgM isolated from patients ascites can bind to naturally expressed P1 on the cell surface of ovarian cancer cells. Cell-sorted IGROV1 was used to obtain two study subpopulations (P1-high, 66.1%; and P1-low, 33.3%) and observed that cells expressing high P1-levels migrate significantly faster than those with low P1-levels. This is the first report showing that P1 antigen, known to be expressed on erythrocytes only, is also present on ovarian cancer cells. This suggests that P1 is a novel tumour-associated carbohydrate antigen recognised by the immune system in patients and may have a role in cell migration. The clinical value of our data

  3. Evaluation of the Alexon-Trend ProSpecT Campylobacter Microplate Assay

    Science.gov (United States)

    Tolcin, Rita; LaSalvia, Margaret M.; Kirkley, Barbara A.; Vetter, Emily A.; Cockerill, Franklin R.; Procop, Gary W.

    2000-01-01

    We evaluated stool specimens known to contain or be free of Campylobacter by traditional culture, using the ProSpecT Campylobacter microplate assay (Alexon-Trend, Ramsey, Minn.). This rapid enzyme immunoassay for the detection of Campylobacter-specific antigens demonstrated 96% sensitivity and 99% specificity and is an acceptable alternative method of Campylobacter detection. PMID:11015419

  4. In vitro stimulation of peripheral blood mononuclear cells (PBMC) from HIV- and HIV+ chancroid patients by Haemophilus ducreyi antigens.

    Science.gov (United States)

    Van Laer, L; Vingerhoets, J; Vanham, G; Kestens, L; Bwayo, J; Otido, J; Piot, P; Roggen, E

    1995-11-01

    The cellular immune responses to fractionated Haemophilus ducreyi antigens, coated on latex beads, were assessed in patients with chancroid and in controls, using an in vitro lymphocyte proliferation assay. Several fractions of H. ducreyi antigen revealed stimulating activity. However, only the molecular size ranges 91-78 kD, 59-29 kD, and 25-21 kD induced proliferation that may be specifically related to H. ducreyi infection. Lymphocytes from four HIV- patients, successfully treated for chancroid, were not stimulated by H. ducreyi antigen. In general, lymphocytes from HIV+ chancroid patients were less responsive to H. ducreyi antigen compared with those from HIV- chancroid patients. However, two HIV-infected patients showed exceptionally strong responses to high molecular weight fractions. To our knowledge this is the first report demonstrating that H. ducreyi contains specific T cell-stimulating antigens. Based on this work, further identification and purification of the T cell antigens is feasible.

  5. Immunodiagnosis of Human Fascioliasis by an Enzyme-Linked Immunosorbent Assay (ELISA) and a Micro-ELISA

    OpenAIRE

    Carnevale, Silvana; Rodríguez, Mónica I.; Santillán, Graciela; Labbé, Jorge H.; Cabrera, Marta G.; Bellegarde, Enrique J.; Velásquez, Jorge N.; Trgovcic, Jorge E.; Guarnera, Eduardo A.

    2001-01-01

    Enzyme-linked immunosorbent assay (ELISA) and micro-ELISA were evaluated for their ability to detect anti-Fasciola hepatica antibodies in humans by using excretory-secretory antigen. The sensitivity of each method was 100%, but the specificity was 100% for ELISA and 97% for micro-ELISA. The micro-ELISA could be used as a screening assay and ELISA could be used as a confirmatory method for the serodiagnosis of human fascioliasis.

  6. Immunoregulatory adherent cells in human tuberculosis: radiation-sensitive antigen-specific suppression by monocytes

    Energy Technology Data Exchange (ETDEWEB)

    Kleinhenz, M.E.; Ellner, J.J.

    1985-07-01

    In human tuberculosis, adherent mononuclear cells (AMC) selectively depress in vitro responses to the mycobacterial antigen tuberculin purified protein derivative (PPD). The phenotype of this antigen-specific adherent suppressor cell was characterized by examining the functional activity of adherent cells after selective depletion of sheep erythrocyte-rosetting T cells or OKM1-reactive monocytes. Adherent cell suppression was studied in the (/sup 3/H)thymidine-incorporation microculture assay by using T cells rigorously depleted of T cells with surface receptors for the Fc portion of IgG (T gamma cells) as antigen-responsive cells. PPD-induced (/sup 3/H)thymidine incorporation by these non gamma T cells was uniformly reduced (mean, 42% +/- 10% (SD)) when autologous AMC were added to non gamma T cells at a ratio of 1:2. Antigen-specific suppression by AMC was not altered by depletion of sheep erythrocyte-rosetting T cells or treatment with indomethacin. However, AMC treated with OKM1 and complement or gamma irradiation (1,500 rads) no longer suppressed tuberculin responses in vitro. These studies identify the antigen-specific adherent suppressor cell in tuberculosis as an OKM1-reactive, non-erythrocyte-rosetting monocyte. The radiosensitivity of this monocyte immunoregulatory function may facilitate its further definition.

  7. Immunoregulatory adherent cells in human tuberculosis: radiation-sensitive antigen-specific suppression by monocytes

    International Nuclear Information System (INIS)

    Kleinhenz, M.E.; Ellner, J.J.

    1985-01-01

    In human tuberculosis, adherent mononuclear cells (AMC) selectively depress in vitro responses to the mycobacterial antigen tuberculin purified protein derivative (PPD). The phenotype of this antigen-specific adherent suppressor cell was characterized by examining the functional activity of adherent cells after selective depletion of sheep erythrocyte-rosetting T cells or OKM1-reactive monocytes. Adherent cell suppression was studied in the [ 3 H]thymidine-incorporation microculture assay by using T cells rigorously depleted of T cells with surface receptors for the Fc portion of IgG (T gamma cells) as antigen-responsive cells. PPD-induced [ 3 H]thymidine incorporation by these non gamma T cells was uniformly reduced (mean, 42% +/- 10% [SD]) when autologous AMC were added to non gamma T cells at a ratio of 1:2. Antigen-specific suppression by AMC was not altered by depletion of sheep erythrocyte-rosetting T cells or treatment with indomethacin. However, AMC treated with OKM1 and complement or gamma irradiation (1,500 rads) no longer suppressed tuberculin responses in vitro. These studies identify the antigen-specific adherent suppressor cell in tuberculosis as an OKM1-reactive, non-erythrocyte-rosetting monocyte. The radiosensitivity of this monocyte immunoregulatory function may facilitate its further definition

  8. Dengue NS1 Antigen - for Early Detection of Dengue Virus Infection

    Directory of Open Access Journals (Sweden)

    Amol Hartalkar

    2015-08-01

    Full Text Available Objectives: To evaluate the efficacy of NS1 antigen assay for early diagnosis of dengue virus infection in a tertiary care hospital. Methods: This cross sectional study was carried out in department of Medicine from August to December 2013. Total 100 patients with dengue fever were included. Complete blood count, alanine aminotransferase (ALT, aspartate aminotransferase (AST, Dengue NS1 antigen and IgM and IgG antibodies of dengue virus were done in all cases. Results: Of the 100 sera tested, 75% were positive for dengue virus infection based on dengue NS1 antigen, IgM antibody and IgG antibody. Dengue NS1 antigen and IgM, IgG antibody were able to detect dengue virus infection between day 1 to day 8 in 92% of samples, 86.7% of samples and 82.6% of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were IgM positive and 62% were IgG positive. Based on the dengue NS1 antigen and IgM antibody combination, 74% were positive for dengue virus infections. Sensitivity of Dengue NS1 antigen was 92.3% and specificity of 74.28% in comparison to IgM antibody. Detection rate increased to 75%, based on the antigen and IgG antibody combination. Sensitivity of dengue NS1 antigen was 90.3% and specificity of 65.8% in comparison to IgG antibody. Conclusion: Dengue NS1 antigen is a useful, sensitive and specific test for early diagnosis of dengue virus infection and it improves diagnostic efficiency in combination with antibody test. Key words: Dengue fever, NS1 antigen. Introduction: Dengue fever (DF is the most common arboviral illness in humans. Each year, an estimated 50-100 million cases of dengue fever and 500,000 cases of dengue hemorrhagic fever occur worldwide, with 30000 deaths (mainly in children. Globally 2.5-3 billion people in approximately 112 tropical and subtropical countries are at risk of dengue.of samples respectively. Sixty nine percent (69% were found positive for dengue NS1 antigen, 65% were Ig

  9. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    Energy Technology Data Exchange (ETDEWEB)

    Elnabrawie, F S; Megahed, Y M; Fahim, F A; Ahmed, A M [Middle Eastern Regional radioisotope center for Arab Countries biochemistry dept. Faculty of science Ain Shams university, cairo, (Egypt)

    1995-10-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack.

  10. A modified direct insulin lodination for insulin radioreceptor assay in human erythrocytes

    International Nuclear Information System (INIS)

    Elnabrawie, F.S.; Megahed, Y.M.; Fahim, F.A.; Ahmed, A.M.

    1995-01-01

    A substitution of iodine in to the inulin molecule will easily lead to a decreased hormonal activity. Nevertheless it cannot be concluded without further investigation that one or several of the tyrosyl groups are directly involve in the degree of iodination and the loss activity has been demonstrated by many workers, (Frenkel-Conrat 1950, and de Zoeten and van Strik, 1961). On the basis of the Frenkel-Conrat experiments, lee 1957 suggested that a mono-substitution of iodine in two tyrosyl groups is possible without loss of biological activity. In general, iodination is easy to perform as usually carried out at room temperature at PH of 7.5 in a phosphate buffer medium (Megahed et al., 1976, 1979). Reaction between antigen and antibody in radioimmunoassay (RIA), immunoradiometric assay (IRMA) and radioreceptor assay (RRA), is detected by radiation emitted from a radioisotope incorporated into the antigen or antibody molecule. Ideally the radiolabelled molecule has an immunoreactivity identical to the natural molecule and this behaves in the same way as in the assay procedure. Oxidation of 125 I-iodide gives rise to the 125 I-iodination which in a mildly alkaline PH (7.5) reacts with the phenolic benzene ring of tyrosine and tyrosyl residues by a process of electrophilic attack

  11. Immunoglobulin M antibodies against CRA and FRA recombinant antigens of Trypanosoma cruzi in chronic chagasic patients.

    Science.gov (United States)

    Vasconcelos, Romero H T; Azevedo, Elisa A N; Cavalcanti, Maria G A M; Silva, Edimilson D; Ferreira, Antonio G P; Morais, Clarice N L; Gomes, Yara M

    2011-05-01

    Previous works of our research group have demonstrated aspects of the humoral immune response of chronic Chagas disease using the cytoplasmatic repetitive antigen (CRA) and the flagellar repetitive antigen (FRA) of Trypanosoma cruzi. The aim of this work was to analyze the presence of specific immunoglobulin M (IgM) antibodies in chronic chagasic patients using these recombinant antigens of T. cruzi. The positivity of IgM in chronic chagasic patients against CRA and FRA antigens was determined by indirect enzyme-linked immunosorbent assay. We reported no statistical significant differences between the levels of IgM for both recombinant antigens and the different chronic clinical forms of Chagas disease. However, a small proportion of chronic chagasic patients analyzed in this study was positive for this antibody isotype. The findings of this study indicate that the IgM antibodies cannot be used to elucidate the differences in the profile of humoral immune response among chronic chagasic patients with different clinical forms using the CRA and FRA recombinant antigens of T. cruzi. Copyright © 2011 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  12. Performance evaluation of the Bio-Rad Laboratories GS HIV Combo Ag/Ab EIA, a 4th generation HIV assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma.

    Science.gov (United States)

    Bentsen, Christopher; McLaughlin, Lisa; Mitchell, Elizabeth; Ferrera, Carol; Liska, Sally; Myers, Robert; Peel, Sheila; Swenson, Paul; Gadelle, Stephane; Shriver, M Kathleen

    2011-12-01

    A multi-center study was conducted to evaluate the Bio-Rad GS HIV Combo Ag/Ab EIA, a 4th generation HIV-1/HIV-2 assay for the simultaneous detection of HIV p24 antigen and antibodies to HIV-1 (groups M and O) and HIV-2 in human serum or plasma in adult and pediatric populations. The objectives of the study were to assess assay performance for the detection of acute HIV infections; sensitivity in known HIV positive samples; percent agreement with HIV status; specificity in low and high risk individuals of unknown HIV status; and to compare assay performance to a 3rd generation HIV assay. The evaluation included testing 9150 samples at four U.S. clinical trial sites, using three kit lots. Unlinked samples were from routine testing, repositories or purchased from vendors. GS HIV Combo Ag/Ab EIA detection in samples from individuals in two separate populations with acute HIV infection was 95.2% (20/21) and 86.4% (38/44). Sensitivity was 100% (1603/1603) in known antibody positive [HIV-1 Groups M and O, and HIV-2] samples. HIV p24 antigen detection was 100% (53/53) in HIV-1 culture supernatants. HIV-1 seroconversion panel detection improved by a range of 0-20 days compared to a 3rd generation HIV test. Specificity was 99.9% (5989/5996) in low risk, 99.9% (959/960) in high risk and 100% (100/100) in pediatric populations. The GS HIV Combo Ag/Ab EIA significantly reduced the diagnostic window when compared to the 3rd generation screening assay, enabling earlier diagnosis of HIV infection. The performance parameters of the Bio-Rad GS HIV Combo Ag/Ab EIA are well suited for use in HIV diagnostic settings. Copyright © 2011 Elsevier B.V. All rights reserved.

  13. IgG responses to Anopheles gambiae salivary antigen gSG6 detect variation in exposure to malaria vectors and disease risk

    DEFF Research Database (Denmark)

    Stone, Will; Bousema, Teun; Jones, Sophie

    2012-01-01

    as the basis of an immuno-assay determining exposure to Afrotropical malaria vectors. In the present study, IgG responses to gSG6 and 6 malaria antigens (CSP, AMA-1, MSP-1, MSP-3, GLURP R1, and GLURP R2) were compared to Anopheles exposure and malaria incidence in a cohort of children from Korogwe district...... with subsequent malaria incidence (test for trend p¿=¿0.004), comparable to malaria antigens MSP-1 and GLURP R2. Our results show that the gSG6 assay is sensitive to micro-epidemiological variations in exposure to Anopheles mosquitoes, and provides a correlate of malaria risk that is unrelated to immune...

  14. Quantitative assay for the measurement of immune responses directed against the human placenta

    Energy Technology Data Exchange (ETDEWEB)

    Davies, M; Sutcliffe, R G [Glasgow Univ. (UK)

    1982-02-12

    A quantitative in vitro immune assay based on the classical chromium release assay has been developed to detect immune responses directed against alien antigens expressed by the developing foetus and present on the maternal-facing surface of the human placenta. A plasma membrane fraction from the surface of the placenta was prepared and the vesicles thus formed were radiolabelled with /sup 51/Cr. The /sup 51/Cr-labelled vesicles, by various criteria, were found to be suitable for use as targets in a release assay. Further, by means of experimentally immunised animals, the target membranes were shown to be capable of detecting both cellular and humoral anti-placental activity.

  15. Comparison of multiple assays for detecting human antibodies directed against antigens on normal and malignant tissue culture cells

    International Nuclear Information System (INIS)

    Rosenberg, S.A.; Schwarz, S.; Anding, H.; Hyatt, C.; Williams, G.M.; Johns Hopkins Univ., Baltimore, Md.

    1977-01-01

    Four separate assays of human antibody reactivity to four separate normal and malignant human tissue culture cells lines from two patients have been evaluated using a single highly-reactive allogeneic serum. The visual end-point cytolysis assay and the chromium-51 release assay were equally sensitive in measuring complement mediated antibody cytotoxicity and both were far more sensitive than a trypan blue dye exclusion assay. The assay of antibody reactivity by hemadsorption technique was about 10 times more sensitive than any of the cytotoxicity assays. This latter assay measures only IgG antibody however. These assays showed that cell lines from different patients may differ greatly in 'reactivity' to an allogeneic serum and emphasized the importance of utilizing tumor and normal cells from the same patient when using tissue culture cells to search for tumor specific reactivity. These observations emphasize the importance of utilizing multiple assays against paired normal and malignant cells from the same patient to be certain of the specificity and magnitude of the measured antibody

  16. Molecular typing for blood group antigens within 40 min by direct polymerase chain reaction from plasma or serum.

    Science.gov (United States)

    Wagner, Franz F; Flegel, Willy A; Bittner, Rita; Döscher, Andrea

    2017-03-01

    Determining blood group antigens by serological methods may be unreliable in certain situations, such as in patients after chronic or massive transfusion. Red cell genotyping offers a complementary approach, but current methods may take much longer than conventional serological typing, limiting their utility in urgent situations. To narrow this gap, we devised a rapid method using direct polymerase chain reaction (PCR) amplification while avoiding the DNA extraction step. DNA was amplified by PCR directly from plasma or serum of blood donors followed by a melting curve analysis in a capillary rapid-cycle PCR assay. We evaluated the single nucleotide polymorphisms underlying the clinically relevant Fy a , Fy b , Jk a and Jk b antigens, with our analysis being completed within 40 min of receiving a plasma or serum sample. The positive predictive value was 100% and the negative predictive value at least 84%. Direct PCR with melting point analysis allowed faster red cell genotyping to predict blood group antigens than any previous molecular method. Our assay may be used as a screening tool with subsequent confirmatory testing, within the limitations of the false-negative rate. With fast turnaround times, the rapid-cycle PCR assay may eventually be developed and applied to red cell genotyping in the hospital setting. © 2016 John Wiley & Sons Ltd.

  17. Purification and characterization of a major human Pneumocystis carinii surface antigen

    DEFF Research Database (Denmark)

    Lundgren, B; Lipschik, G Y; Kovacs, J A

    1991-01-01

    . To evaluate humoral immune responses to the human P. carinii protein, an enzyme-linked immunosorbent assay using purified protein was developed. Some, but not all, patients who subsequently developed P. carinii pneumonia demonstrated a serum antibody response to the surface antigen. Nearly all subjects...... without a history of P. carinii pneumonia had no detectable antibodies. Purified P. carinii proteins will greatly facilitate the investigation of host-P. carinii interactions....

  18. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen.

    Science.gov (United States)

    Bannai, Hiroshi; Nemoto, Manabu; Tsujimura, Koji; Yamanaka, Takashi; Maeda, Ken; Kondo, Takashi

    2016-02-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA.

  19. Immune Monitoring in Cancer Vaccine Clinical Trials: Critical Issues of Functional Flow Cytometry-Based Assays

    Directory of Open Access Journals (Sweden)

    Iole Macchia

    2013-01-01

    Full Text Available The development of immune monitoring assays is essential to determine the immune responses against tumor-specific antigens (TSAs and tumor-associated antigens (TAAs and their possible correlation with clinical outcome in cancer patients receiving immunotherapies. Despite the wide range of techniques used, to date these assays have not shown consistent results among clinical trials and failed to define surrogate markers of clinical efficacy to antitumor vaccines. Multiparameter flow cytometry- (FCM- based assays combining different phenotypic and functional markers have been developed in the past decade for informative and longitudinal analysis of polyfunctional T-cells. These technologies were designed to address the complexity and functional heterogeneity of cancer biology and cellular immunity and to define biomarkers predicting clinical response to anticancer treatment. So far, there is still a lack of standardization of some of these immunological tests. The aim of this review is to overview the latest technologies for immune monitoring and to highlight critical steps involved in some of the FCM-based cellular immune assays. In particular, our laboratory is focused on melanoma vaccine research and thus our main goal was the validation of a functional multiparameter test (FMT combining different functional and lineage markers to be applied in clinical trials involving patients with melanoma.

  20. Antigenic characterization of a formalin-inactivated poliovirus vaccine derived from live-attenuated Sabin strains.

    Science.gov (United States)

    Tano, Yoshio; Shimizu, Hiroyuki; Martin, Javier; Nishimura, Yorihiro; Simizu, Bunsiti; Miyamura, Tatsuo

    2007-10-10

    A candidate inactivated poliovirus vaccine derived from live-attenuated Sabin strains (sIPV), which are used in the oral poliovirus vaccine (OPV), was prepared in a large-production scale. The modification of viral antigenic epitopes during the formalin inactivation process was investigated by capture ELISA assays using type-specific and antigenic site-specific monoclonal antibodies (MoAbs). The major antigenic site 1 was modified during the formalin inactivation of Sabin 1. Antigenic sites 1-3 were slightly modified during the formalin inactivation of Sabin 2 strain. Sites 1 and 3 were altered on inactivated Sabin 3 virus. These alterations were different to those shown by wild-type Saukett strain, used in conventional IPV (cIPV). It has been previously reported that type 1 sIPV showed higher immunogenicity to type 1 cIPV whereas types 2 and 3 sIPV induced lower level of immunogenicity than their cIPV counterparts. Our results suggest that the differences in epitope structure after formalin inactivation may account, at least in part, for the observed differences in immunogenicity between Sabin and wild-type inactivated poliovaccines.

  1. Evaluation of the ability of N-terminal fragment of lethal factor of Bacillus anthracis for delivery of Mycobacterium T cell antigen ESAT-6 into cytosol of antigen presenting cells to elicit effective cytotoxic T lymphocyte response

    International Nuclear Information System (INIS)

    Chandra, Subhash; Kaur, Manpreet; Midha, Shuchi; Bhatnagar, Rakesh; Banerjee-Bhatnagar, Nirupama

    2006-01-01

    We report the ability of N-terminal fragment of lethal factor of Bacillus anthracis to deliver genetically fused ESAT-6 (early secretory antigen target), a potent T cell antigen of Mycobacterium tuberculosis, into cytosol to elicit Cytotoxic T lymphocyte (CTL) response. In vitro Th1 cytokines data and CTL assay proved that efficient delivery of LFn.ESAT-6 occurs in cytosol, in the presence of protective antigen (PA), and leads to generation of effective CTL response. Since CTL response is essential for protection against intracellular pathogens and, it is well known that only single T cell epitope or single antigenic protein is not sufficient to elicit protective CTL response due to variation or polymorphism in MHC-I alleles among the individuals, we suggest that as a fusion protein LFn can be used to deliver multiepitopes of T cells or multiproteins which can generate effective CTLs against intracellular pathogens like M. tuberculosis. It can be used to enhance the protective efficacy of BCG vaccine

  2. Monoclonal antibodies to human factor VII: a one step immunoradiometric assay for VII:Ag.

    OpenAIRE

    Takase, T; Tuddenham, E G; Chand, S; Goodall, A H

    1988-01-01

    Three mouse monoclonal antibodies (RFF-VII/1, RFF-VII/2, and RFF-VII/3) which bind specifically to different epitopes on human factor VII antigen were raised. Two of the antibodies, RFF-VII/1 and RFF-VII/2, bound strongly to factor VII antigen (VII:Ag), but only RFF-VII/1 and RFF-VII/3 were potent inhibitors of factor VII coagulation activity (VII:C). RFF-VII/1 and RFF-VII/2 were used in a one step, double monoclonal immunoradiometric assay for VII:Ag. This was highly reproducible and detecte...

  3. Analytical validation of a reference laboratory ELISA for the detection of feline leukemia virus p27 antigen.

    Science.gov (United States)

    Buch, Jesse S; Clark, Genevieve H; Cahill, Roberta; Thatcher, Brendon; Smith, Peter; Chandrashekar, Ramaswamy; Leutenegger, Christian M; O'Connor, Thomas P; Beall, Melissa J

    2017-09-01

    Feline leukemia virus (FeLV) is an oncogenic retrovirus of cats. Immunoassays for the p27 core protein of FeLV aid in the detection of FeLV infections. Commercial microtiter-plate ELISAs have rapid protocols and visual result interpretation, limiting their usefulness in high-throughput situations. The purpose of our study was to validate the PetChek FeLV 15 ELISA, which is designed for the reference laboratory, and incorporates sequential, orthogonal screening and confirmatory protocols. A cutoff for the screening assay was established with 100% accuracy using 309 feline samples (244 negative, 65 positive) defined by the combined results of FeLV PCR and an independent reference p27 antigen ELISA. Precision of the screening assay was measured using a panel of 3 samples (negative, low-positive, and high-positive). The intra-assay coefficient of variation (CV) was 3.9-7.9%; the inter-assay CV was 6.0-8.6%. For the confirmatory assay, the intra-assay CV was 3.0-4.7%, and the inter-assay CV was 7.4-9.7%. The analytical sensitivity for p27 antigen was 3.7 ng/mL for inactivated whole FeLV and 1.2 ng/mL for purified recombinant FeLV p27. Analytical specificity was demonstrated based on the absence of cross-reactivity to related retroviruses. No interference was observed for samples containing added bilirubin, hemoglobin, or lipids. Based on these results, the new high-throughput design of the PetChek FeLV 15 ELISA makes it suitable for use in reference laboratory settings and maintains overall analytical performance.

  4. Evaluation of Selected Borrelia burgdorferi lp54 Plasmid-Encoded Gene Products Expressed during Mammalian Infection as Antigens To Improve Serodiagnostic Testing for Early Lyme Disease

    Science.gov (United States)

    Weiner, Zachary P.; Crew, Rebecca M.; Brandt, Kevin S.; Ullmann, Amy J.; Schriefer, Martin E.; Molins, Claudia R.

    2015-01-01

    Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. PMID:26376927

  5. Evaluation of Selected Borrelia burgdorferi lp54 Plasmid-Encoded Gene Products Expressed during Mammalian Infection as Antigens To Improve Serodiagnostic Testing for Early Lyme Disease.

    Science.gov (United States)

    Weiner, Zachary P; Crew, Rebecca M; Brandt, Kevin S; Ullmann, Amy J; Schriefer, Martin E; Molins, Claudia R; Gilmore, Robert D

    2015-11-01

    Laboratory testing for the diagnosis of Lyme disease is performed primarily by serologic assays and is accurate for detection beyond the acute stage of the infection. Serodiagnostic assays to detect the early stages of infection, however, are limited in their sensitivity, and improvement is warranted. We analyzed a series of Borrelia burgdorferi proteins known to be induced within feeding ticks and/or during mammalian infection for their utility as serodiagnostic markers against a comprehensive panel of Lyme disease patient serum samples. The antigens were assayed for IgM and IgG reactivity in line immunoblots and separately by enzyme-linked immunosorbent assay (ELISA), with a focus on reactivity against early Lyme disease with erythema migrans (EM), early disseminated Lyme neuroborreliosis, and early Lyme carditis patient serum samples. By IgM immunoblotting, we found that recombinant proteins BBA65, BBA70, and BBA73 reacted with early Lyme EM samples at levels comparable to those of the OspC antigen used in the current IgM blotting criteria. Additionally, these proteins reacted with serum samples from patients with early neuroborreliosis and early carditis, suggesting value in detecting early stages of this disease progression. We also found serological reactivity against recombinant proteins BBA69 and BBA73 with early-Lyme-disease samples using IgG immunoblotting and ELISA. Significantly, some samples that had been scored negative by the Centers for Disease Control and Prevention-recommended 2-tiered testing algorithm demonstrated positive reactivity to one or more of the antigens by IgM/IgG immunoblot and ELISA. These results suggest that incorporating additional in vivo-expressed antigens into the current IgM/IgG immunoblotting tier in a recombinant protein platform assay may improve the performance of early-Lyme-disease serologic testing. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  6. B-cell responses to pregnancy-restricted and -unrestricted Plasmodium falciparum erythrocyte membrane protein 1 antigens in Ghanaian women naturally exposed to malaria parasites

    DEFF Research Database (Denmark)

    Ampomah, Paulina; Stevenson, Liz; Ofori, Michael F

    2014-01-01

    -linked immunosorbent assay (ELISA) and memory B-cell frequencies by enzyme-linked immunosorbent spot (ELISPOT) assay in a cohort of P. falciparum-exposed nonpregnant Ghanaian women. The antigens used were a VAR2CSA-type PfEMP1 (IT4VAR04) with expression restricted to parasites infecting the placenta, as well as two...... commonly recognized PfEMP1 proteins (HB3VAR06 and IT4VAR60) implicated in rosetting and not pregnancy restricted. This enabled, for the first time, a direct comparison in the same individuals of immune responses specific for a clinically important parasite antigen expressed only during well-defined periods...

  7. Immunochemical characterization of Mycobacterium leprae antigens by the SDS-polyacrylamide gel electrophoresis immunoperoxidase technique (SGIP) using patients' sera

    NARCIS (Netherlands)

    Klatser, P. R.; van Rens, M. M.; Eggelte, T. A.

    1984-01-01

    In this study the SDS-polyacrylamide gel electrophoresis immunoperoxidase (SGIP) assay was used for characterizing the antigenic components of Mycobacterium leprae using patients' sera. This technique involved the separation of mycobacterial sonicates on SDS-polyacrylamide gels, longitudinal

  8. The accuracy of serum galactomannan assay in diagnosing invasive pulmonary aspergillosis.

    Science.gov (United States)

    Sarrafzadeh, Shokooh Azam; Hoseinpoor Rafati, Ali; Ardalan, Maryam; Mansouri, Davood; Tabarsi, Payam; Pourpak, Zahra

    2010-09-01

    Galactomannan (GM) antigen is an aspergillus specific antigen that is released during the growth phase of invasive aspergillosis. We aimed to find the optimum cutoff and accuracy of serum Galactomannan assay in immunocompromised patients. Immunocompromised patients diagnosed with invasive pulmonary aspergillosis (IPA) based on the European Organization for Research and Treatment of Cancer/Invasive Mycosis Study Group (EORTC/MSG) with three levels of certainty proven, probable and possible, referred for GM antigen measurement at Immunology, Asthma and Allergy Research Institute (IAARI) from 2006 to 2009 and if they met the criteria were enrolled in this study. Totally 49 patients with IPA were enrolled in our study. According to EORTC/MSG, patients categorized into three levels of certainty: They were diagnosed as 'proven' invasive pulmonary aspergillosis 16(32.7%), 'probable' 18(36.7%) and 'possible' 15(30.6%). The most common host risk factor was solid tumors 17(34.7%). The accuracy of Galactomannan assay increased from 0.5 to 2 cutoffs. The optimum sensitivity and specificity obtained at the index cutoff of ≥1.5 for diagnosis of "proven" IPA; which were respectively, 69.2% and 72.2%. Other cutoffs had high variance between sensitivity and specificity for diagnosis of IPA. The calculated cutoff gained by receiver operating characteristic (ROC) analysis for detecting proven IPA was 1.5. Intermediate accuracy of serum GM test in conjunct with clinical findings would help early IPA detection among immunocompromised patients.

  9. Determining the binding affinity of therapeutic monoclonal antibodies towards their native unpurified antigens in human serum.

    Directory of Open Access Journals (Sweden)

    Christine Bee

    Full Text Available Monoclonal antibodies (mAbs are a growing segment of therapeutics, yet their in vitro characterization remains challenging. While it is essential that a therapeutic mAb recognizes the native, physiologically occurring epitope, the generation and selection of mAbs often rely on the use of purified recombinant versions of the antigen that may display non-native epitopes. Here, we present a method to measure both, the binding affinity of a therapeutic mAb towards its native unpurified antigen in human serum, and the antigen's endogenous concentration, by combining the kinetic exclusion assay and Biacore's calibration free concentration analysis. To illustrate the broad utility of our method, we studied a panel of mAbs raised against three disparate soluble antigens that are abundant in the serum of healthy donors: proprotein convertase subtilisin/kexin type 9 (PCSK9, progranulin (PGRN, and fatty acid binding protein (FABP4. We also determined the affinity of each mAb towards its purified recombinant antigen and assessed whether the interactions were pH-dependent. Of the six mAbs studied, three did not appear to discriminate between the serum and recombinant forms of the antigen; one mAb bound serum antigen with a higher affinity than recombinant antigen; and two mAbs displayed a different affinity for serum antigen that could be explained by a pH-dependent interaction. Our results highlight the importance of taking pH into account when measuring the affinities of mAbs towards their serum antigens, since the pH of serum samples becomes increasingly alkaline upon aerobic handling.

  10. A Bacterial Glycoengineered Antigen for Improved Serodiagnosis of Porcine Brucellosis.

    Science.gov (United States)

    Cortina, María E; Balzano, Rodrigo E; Rey Serantes, Diego A; Caillava, Ana J; Elena, Sebastián; Ferreira, A C; Nicola, Ana M; Ugalde, Juan E; Comerci, Diego J; Ciocchini, Andrés E

    2016-06-01

    Brucellosis is a highly zoonotic disease that affects animals and human beings. Brucella suis is the etiological agent of porcine brucellosis and one of the major human brucellosis pathogens. Laboratory diagnosis of porcine brucellosis mainly relies on serological tests, and it has been widely demonstrated that serological assays based on the detection of anti O-polysaccharide antibodies are the most sensitive tests. Here, we validate a recombinant glycoprotein antigen, an N-formylperosamine O-polysaccharide-protein conjugate (OAg-AcrA), for diagnosis of porcine brucellosis. An indirect immunoassay based on the detection of anti-O-polysaccharide IgG antibodies was developed coupling OAg-AcrA to enzyme-linked immunosorbent assay plates (glyco-iELISA). To validate the assay, 563 serum samples obtained from experimentally infected and immunized pigs, as well as animals naturally infected with B. suis biovar 1 or 2, were tested. A receiver operating characteristic (ROC) analysis was performed, and based on this analysis, the optimum cutoff value was 0.56 (relative reactivity), which resulted in a diagnostic sensitivity and specificity of 100% and 99.7%, respectively. A cutoff value of 0.78 resulted in a test sensitivity of 98.4% and a test specificity of 100%. Overall, our results demonstrate that the glyco-iELISA is highly accurate for diagnosis of porcine brucellosis, improving the diagnostic performance of current serological tests. The recombinant glycoprotein OAg-AcrA can be produced in large homogeneous batches in a standardized way, making it an ideal candidate for further validation as a universal antigen for diagnosis of "smooth" brucellosis in animals and humans. Copyright © 2016, American Society for Microbiology. All Rights Reserved.

  11. Detection of Serum Thermolabile β-2 Macroglycoprotein (Hakata Antigen) by Enzyme-Linked Immunosorbent Assay Using Polysaccharide Produced by Aerococcus viridans

    Science.gov (United States)

    Tsujimura, Mitsushi; Ishida, Chuzo; Sagara, Yasuko; Miyazaki, Takashi; Murakami, Koichi; Shiraki, Hiroshi; Okochi, Kazuo; Maeda, Yoshiaki

    2001-01-01

    Although a serum thermolabile β-2 macroglycoprotein (TMG) may play a role in host defense as a lectin, little is known of its related physiological functions, mainly due to a lack of appropriate methods for tracing the functions of TMG. We identified a polysaccharide from Aerococcus viridans, PSA, which reacts with TMG, and based on this finding, we developed an enzyme-linked immunosorbent assay to trace the functions of TMG. Using ethanol precipitation and DEAE-Sepharose and Sephacryl S-400 column chromatographies, we isolated PSA from cultured medium of A. viridans, and it exhibited specific binding against TMG in blood samples. In sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), the isolated PSA showed ladder bands that implied the existence of repeating units composed of d-glucose, N-acetyl-d-glucosamine, d-mannose, and d-xylose, as confirmed by gas chromatography-mass spectrometry. SDS-PAGE and immunochemical analysis, using rabbit anti-TMG antibody, showed that PSA specifically binds solely to intact serum TMG but not to TMG heated at 56°C for 30 min, a condition under which antigenicity is lost. TMG in serum samples bound to PSA in a dose-dependent manner, and this binding was clearly suppressed by addition of PSA. These observations indicate that PSA is a useful adsorbent to TMG and can be used to develop appropriate methods for tracing the functions of TMG. PMID:11238239

  12. Effects of roasting, blanching, autoclaving, and microwave heating on antigenicity of almond (Prunus dulcis L.) proteins.

    Science.gov (United States)

    Venkatachalam, M; Teuber, S S; Roux, K H; Sathe, S K

    2002-06-05

    Whole, unprocessed Nonpareil almonds were subjected to a variety of heat processing methods that included roasting (280, 300, and 320 degrees F for 20 and 30 min each; and 335 and 350 degrees F for 8, 10, and 12 min each), autoclaving (121 degrees C, 15 psi, for 5, 10, 15, 20, 25, and 30 min), blanching (100 degrees C for 1, 2, 3, 4, 5, and 10 min), and microwave heating (1, 2, and 3 min). Proteins were extracted from defatted almond flour in borate saline buffer, and immunoreactivity of the soluble proteins (normalized to 1 mg protein/mL for all samples) was determined using enzyme linked immunosorbent assay (ELISA). Antigenic stability of the almond major protein (amandin) in the heat-processed samples was determined by competitive inhibition ELISA using rabbit polyclonal antibodies raised against amandin. Processed samples were also assessed for heat stability of total antigenic proteins by sandwich ELISA using goat and rabbit polyclonal antibodies raised against unprocessed Nonpareil almond total protein extract. ELISA assays and Western blotting experiments that used both rabbit polyclonal antibodies and human IgE from pooled sera indicated antigenic stability of almond proteins when compared with that of the unprocessed counterpart.

  13. A solid phase radio immunoassay on hydrophobic membrane filters: detection of antibodies to gonocal surface antigens

    International Nuclear Information System (INIS)

    Lambden, P.R.; Watt, P.J.

    1978-01-01

    A solid phase radioimmunoassay (SPRIA) has been developed for detection of IgG antibodies to gonococcal outer membrane components. Gonococcal antigens was immobilised on a solid support by covalent coupling to CNBr-activated Sepharose in the presence of the detergent Triton X-100. Binding of specific antibody to the Sepharose-antigen complex was detected using radiolabelled Protein A as the antiglobulin. Protein A was labelled by radioacetylation with tritiated acetic anhydride, yielding a product of high specific activity and high stability. No detectable loss of activity was observed over a ten month period. The entire assay was performed on Mitex teflon hydrophobic membrane filters which held the Sepharose beads and aqueous supernatant as a discrete drop of liquid. The supernatants and incubation were easily and rapidly removed from the beads by suction on a specially-designed manifold system. This procedure removed the need for repeated and time-consuming centrifugations. Titres were obtained graphically from double log plots of cpm bound versus antiserum dilution by extrapolation of the straight line to a point corresponding to twice the control level of radioactivity binding. The assay proved to be a very reliable and simple procedure for the detection of IgG antibodies to gonococcal surface antigens. (Auth.)

  14. Transmission of hepatitis-B virus through salivary blood group antigens in saliva

    International Nuclear Information System (INIS)

    Meo, S.A.; Abdo, A.A.; Baksh, N.D.; Sanie, F.M.

    2010-01-01

    To determine an association between transmission of hepatitis B virus and secretor and non-secretor status of salivary blood group antigens. Study Design: Cross-sectional, analytical study. Place and Duration of Study: The Department of Physiology and Division of Hepatology, College of Medicine, King Khalid University Hospital, King Saud University, Riyadh, Kingdom of Saudi Arabia, from 2007 to 2009. Methodology: Eighty eight known patients, who were positive for Hepatitis B Surface Antigen [HBsAg] were recruited. Saliva was collected for investigating the secretor and non-secretor status by using blood typing kit number Kemtec Educational Science USA. Hepatitis B Surface antigen test was performed on Enzyme Linked Immunosorbent Assay technique. Polymerase chain reaction [PCR] on saliva was also carried out in High Performance Thermal Cycler-Palm- Cycler [Corbett Life Science, Sydney, Australia] and enzymatic amplification of extracted viral DNA was performed using primers covering the promoter of the core region of HBV. Results: Out of the 88 subjects, 61 belong to blood group O, 20 to A and 7 subjects to blood group B. Fifty subjects were secretors [salivary blood group antigens positive] and 38 subjects were non-secretors [salivary blood group antigens negative]. Among core gene positive 25 (69.4%) were secretors and 11 (30.6%) were non-secretors. However, in core gene negative 25 (48.1%) were secretors and 27 (51.9%) were non-secretors. Conclusion: The result shows an association [p=0.047] between secretor and non-secretors status of the salivary blood group antigens with core gene positive and core gene negative. (author)

  15. Detection of anti-spermatozoal antibodies by a 125I-protein-A radioimmunological assay

    International Nuclear Information System (INIS)

    Czuppon, A.B.

    1985-01-01

    A newly developed solid-phase radioimmunobinding assay (RIBA) using detergent-solubilized sperm antigen has been used to evaluate anti-sperm antibodies. Results showed that none of the fertile females and males were positive in the RIBA, whereas approximately 6% of the females and 3% of the males with unexplained infertility were positive. These results are similar to those obtained using a chemically synthesized spermatozoal decapeptide antigen. The RIBA is simple to perform, requires no vital or intact spermatozoa, and large numbers of sera (up to 400) can be processed in one day with a total incubation time of 90 min. (Auth.)

  16. Cytokine responses to novel antigens in an Indian population living in an area endemic for visceral leishmaniasis.

    Science.gov (United States)

    Singh, Om Prakash; Stober, Carmel B; Singh, Abhishek Kr; Blackwell, Jenefer M; Sundar, Shyam

    2012-01-01

    There are no effective vaccines for visceral leishmaniasis (VL), a neglected parasitic disease second only to malaria in global mortality. We previously identified 14 protective candidates in a screen of 100 Leishmania antigens as DNA vaccines in mice. Here we employ whole blood assays to evaluate human cytokine responses to 11 of these antigens, in comparison to known defined and crude antigen preparations. Whole blood assays were employed to measure IFN-γ, TNF-α and IL-10 responses to peptide pools of the novel antigens R71, Q51, L37, N52, L302.06, J89, M18, J41, M22, M63, M57, as well as to recombinant proteins of tryparedoxin peroxidase (TRYP), Leishmania homolog of the receptor for activated C kinase (LACK) and to crude soluble Leishmania antigen (SLA), in Indian patients with active (n = 8) or cured (n = 16) VL, and in modified Quantiferon positive (EHC(+ve), n = 20) or modified Quantiferon negative (EHC(-ve), n = 9) endemic healthy controls (EHC). Active VL, cured VL and EHC(+ve) groups showed elevated SLA-specific IFN-γ, but only active VL patients produced IL-10 and EHC(+ve) did not make TNF-α. IFN-γ to IL-10 and TNF-α to IL-10 ratios in response to TRYP and LACK antigens were higher in cured VL and EHC(+ve) exposed individuals compared to active VL. Five of the eleven novel candidates (R71, L37, N52, J41, and M22) elicited IFN-γ and TNF-α, but not IL-10, responses in cured VL (55-87.5% responders) and EHC(+ve) (40-65% responders) subjects. Our results are consistent with an important balance between pro-inflammatory IFNγ and TNFγ cytokine responses and anti-inflammatory IL-10 in determining outcome of VL in India, as highlighted by response to both crude and defined protein antigens. Importantly, cured VL patients and endemic Quantiferon positive individuals recognise 5 novel vaccine candidate antigens, confirming our recent data for L. chagasi in Brazil, and their potential as cross-species vaccine candidates.

  17. Cytokine responses to novel antigens in an Indian population living in an area endemic for visceral leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Om Prakash Singh

    Full Text Available There are no effective vaccines for visceral leishmaniasis (VL, a neglected parasitic disease second only to malaria in global mortality. We previously identified 14 protective candidates in a screen of 100 Leishmania antigens as DNA vaccines in mice. Here we employ whole blood assays to evaluate human cytokine responses to 11 of these antigens, in comparison to known defined and crude antigen preparations.Whole blood assays were employed to measure IFN-γ, TNF-α and IL-10 responses to peptide pools of the novel antigens R71, Q51, L37, N52, L302.06, J89, M18, J41, M22, M63, M57, as well as to recombinant proteins of tryparedoxin peroxidase (TRYP, Leishmania homolog of the receptor for activated C kinase (LACK and to crude soluble Leishmania antigen (SLA, in Indian patients with active (n = 8 or cured (n = 16 VL, and in modified Quantiferon positive (EHC(+ve, n = 20 or modified Quantiferon negative (EHC(-ve, n = 9 endemic healthy controls (EHC.Active VL, cured VL and EHC(+ve groups showed elevated SLA-specific IFN-γ, but only active VL patients produced IL-10 and EHC(+ve did not make TNF-α. IFN-γ to IL-10 and TNF-α to IL-10 ratios in response to TRYP and LACK antigens were higher in cured VL and EHC(+ve exposed individuals compared to active VL. Five of the eleven novel candidates (R71, L37, N52, J41, and M22 elicited IFN-γ and TNF-α, but not IL-10, responses in cured VL (55-87.5% responders and EHC(+ve (40-65% responders subjects.Our results are consistent with an important balance between pro-inflammatory IFNγ and TNFγ cytokine responses and anti-inflammatory IL-10 in determining outcome of VL in India, as highlighted by response to both crude and defined protein antigens. Importantly, cured VL patients and endemic Quantiferon positive individuals recognise 5 novel vaccine candidate antigens, confirming our recent data for L. chagasi in Brazil, and their potential as cross-species vaccine candidates.

  18. Studies of cytotoxic antibodies against eye muscle antigens in patients with thyroid-associated ophthalmopathy

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R. (Thyroid Research Unit, The Montreal General Hospital Research Institute, Montreal, Quebec (Canada)); Medeiros-Neto, G.; Iacona, A.; Lima, N. (Thyroid Clinic, Hospital das Clinicas, Sao Paulo (Brazil))

    1989-01-01

    We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in {sup 51}Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of {sup 51}Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. (Abstract Truncated)

  19. Computational Identification of Antigenicity-Associated Sites in the Hemagglutinin Protein of A/H1N1 Seasonal Influenza Virus.

    Directory of Open Access Journals (Sweden)

    Xiaowei Ren

    Full Text Available The antigenic variability of influenza viruses has always made influenza vaccine development challenging. The punctuated nature of antigenic drift of influenza virus suggests that a relatively small number of genetic changes or combinations of genetic changes may drive changes in antigenic phenotype. The present study aimed to identify antigenicity-associated sites in the hemagglutinin protein of A/H1N1 seasonal influenza virus using computational approaches. Random Forest Regression (RFR and Support Vector Regression based on Recursive Feature Elimination (SVR-RFE were applied to H1N1 seasonal influenza viruses and used to analyze the associations between amino acid changes in the HA1 polypeptide and antigenic variation based on hemagglutination-inhibition (HI assay data. Twenty-three and twenty antigenicity-associated sites were identified by RFR and SVR-RFE, respectively, by considering the joint effects of amino acid residues on antigenic drift. Our proposed approaches were further validated with the H3N2 dataset. The prediction models developed in this study can quantitatively predict antigenic differences with high prediction accuracy based only on HA1 sequences. Application of the study results can increase understanding of H1N1 seasonal influenza virus antigenic evolution and accelerate the selection of vaccine strains.

  20. Locus-specific detection of HLA-DQ and -DR antigens by antibodies against synthetic N-terminal octapeptides of the beta chain

    DEFF Research Database (Denmark)

    Deufel, T; Grove, A; Kofod, Hans

    1985-01-01

    Antibodies against synthetic peptides representing the class-II antigen HLA-DR and -DQ beta chain N-terminal sequences were prepared in rabbits. The two octapeptides only share two amino acids and enzyme-linked immuno-assays showed the antisera only to bind to its own antigen. Both peptide antisera...... chains of HLA-DR and -DQ have been prepared by the preparation by the production of antibodies against the N-terminal sequences of each polypeptide....

  1. Identification of new antigen candidates for the early diagnosis of Mycobacterium avium subsp. paratuberculosis infection in goats

    NARCIS (Netherlands)

    Souriau, Armel; Freret, Sandrine; Foret, Benjamin; Willemsen, Peter T.J.; Bakker, Douwe; Guilloteau, Laurence A.

    2017-01-01

    Currently Mycobacterium avium subsp. paratuberculosis (MAP) infection is diagnosed through indirect tests based on the immune response induced by the infection. The antigens commonly used in IFN-γ release assays (IGRA) are purified protein derivative tuberculins (PPD). However, PPDs, lack both

  2. Challenges and opportunities of using liquid chromatography and mass spectrometry methods to develop complex vaccine antigens as pharmaceutical dosage forms.

    Science.gov (United States)

    Hickey, John M; Sahni, Neha; Toth, Ronald T; Kumru, Ozan S; Joshi, Sangeeta B; Middaugh, C Russell; Volkin, David B

    2016-10-01

    Liquid chromatographic methods, combined with mass spectrometry, offer exciting and important opportunities to better characterize complex vaccine antigens including recombinant proteins, virus-like particles, inactivated viruses, polysaccharides, and protein-polysaccharide conjugates. The current abilities and limitations of these physicochemical methods to complement traditional in vitro and in vivo vaccine potency assays are explored in this review through the use of illustrative case studies. Various applications of these state-of-the art techniques are illustrated that include the analysis of influenza vaccines (inactivated whole virus and recombinant hemagglutinin), virus-like particle vaccines (human papillomavirus and hepatitis B), and polysaccharide linked to protein carrier vaccines (pneumococcal). Examples of utilizing these analytical methods to characterize vaccine antigens in the presence of adjuvants, which are often included to boost immune responses as part of the final vaccine dosage form, are also presented. Some of the challenges of using chromatographic and LC-MS as physicochemical assays to routinely test complex vaccine antigens are also discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Immunodetection of Fasciola gigantica circulating antigen in sera of infected individuals for laboratory diagnosis of human fascioliasis.

    Science.gov (United States)

    Attallah, Abdelfattah M; Bughdadi, Faisal A; El-Shazly, Atef M; Ismail, Hisham

    2013-10-01

    Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P 93%), and a significant correlation (r = 0.715, P fascioliasis.

  4. IDENTIFICATION OF ACROSOME AS THE MAIN ANTIGEN OF THE SPERM CELLS PROVOKING AUTOANTIBODIES IN VASECTOMIZED IRANIAN MEN

    Directory of Open Access Journals (Sweden)

    M R Nowroozi

    2008-12-01

    Full Text Available "nVasectomy is one of the extensively used methods of contraception in family planning programs. Antisperm antibodies (ASA develop after vasectomy which can result in auto-immune male infertility. The precise sperm antigens involved in the autoimmune response are still poorly defined, therefore we determined the circulating ASA and identified relevant sperm antigens based on localization of binding sites of ASA to sperm cell antigens, using a rapid, inexpensive and clinically relevant assay in vasectomized men. Results showed that 2.5% of men had ASA at the time of vasectomy, whereas 53.5% of the study population subsequently developed ASA. The numbers of men with circulating ASA increased significantly for the first three months after vasectomy. These antibodies were distinguishable into three groups based on their bindings to different sites of sperm cell antigens including against acrosome and tail in 67.56% and 10.8%, respectively; 21.6% of subjects had antibody to the other parts of the sperm cell antigens. The results of this study are discussed in terms of an autoimmune response against sperm antigens and development of ASA.

  5. Effect of radiation on the expression of tumor-associated antigens of human lung adenocarcinoma cells. Immunological study using monoclonal antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Hareyama, Masato

    1988-12-01

    We studied the effects of irradiation on the expression of a tumor-associated antigen (YH206 antigen) of cultured human lung adenocarcinoma A549 cells by using enzyme-linked immunosorbent assay (ELISA) and flow cytometry. YH206 antigen is preferentially expressed on adenocarcinoma cells. Irradiation of A549 cells remarkably increased the expression of YH206 antigen on the cell surface and the level of the antigen in the culture supernatant as well as in the cell lysate, whereas it significantly affected the expression of HLA (MHC-class I) antigen on the same cells. The expression of HLA antigen on the cell was also increased after treatment of the cells with interferon-..gamma... In an additional experiment, cells were stained simultaneously for surface antigens (fluorescein coupled antibodies) and for DNA content (propidium iodide), and then dual parameter measurements were performed by flow cytometry to analyse the relationship between antigen levels and the cell cycle. YH206 antigen and HLA antigen increased more in the S and G/sub 2//M phases of the cell cycle than in G/sub 0//G/sub 1/. The expression of YH206 antigen was enhanced in the S and G/sub 2//M phases by irradiation, whereas the expression of HLA antigen was enhanced in each phase of the cell cycle with irradiation or IFN. These results suggest that irradiation plays a key role in the change of the expression of certain tumor-associated antigens.

  6. Low cost tuberculosis vaccine antigens in capsules: expression in chloroplasts, bio-encapsulation, stability and functional evaluation in vitro.

    Directory of Open Access Journals (Sweden)

    Priya Saikumar Lakshmi

    Full Text Available Tuberculosis (TB caused by Mycobacterium tuberculosis is one of the leading fatal infectious diseases. The development of TB vaccines has been recognized as a major public health priority by the World Health Organization. In this study, three candidate antigens, ESAT-6 (6 kDa early secretory antigenic target and Mtb72F (a fusion polyprotein from two TB antigens, Mtb32 and Mtb39 fused with cholera toxin B-subunit (CTB and LipY (a cell wall protein were expressed in tobacco and/or lettuce chloroplasts to facilitate bioencapsulation/oral delivery. Site-specific transgene integration into the chloroplast genome was confirmed by Southern blot analysis. In transplastomic leaves, CTB fusion proteins existed in soluble monomeric or multimeric forms of expected sizes and their expression levels varied depending upon the developmental stage and time of leaf harvest, with the highest-level of accumulation in mature leaves harvested at 6PM. The CTB-ESAT6 and CTB-Mtb72F expression levels reached up to 7.5% and 1.2% of total soluble protein respectively in mature tobacco leaves. Transplastomic CTB-ESAT6 lettuce plants accumulated up to 0.75% of total leaf protein. Western blot analysis of lyophilized lettuce leaves stored at room temperature for up to six months showed that the CTB-ESAT6 fusion protein was stable and preserved proper folding, disulfide bonds and assembly into pentamers for prolonged periods. Also, antigen concentration per gram of leaf tissue was increased 22 fold after lyophilization. Hemolysis assay with purified CTB-ESAT6 protein showed partial hemolysis of red blood cells and confirmed functionality of the ESAT-6 antigen. GM1-binding assay demonstrated that the CTB-ESAT6 fusion protein formed pentamers to bind with the GM1-ganglioside receptor. The expression of functional Mycobacterium tuberculosis antigens in transplastomic plants should facilitate development of a cost-effective and orally deliverable TB booster vaccine with potential

  7. Low cost tuberculosis vaccine antigens in capsules: expression in chloroplasts, bio-encapsulation, stability and functional evaluation in vitro.

    Science.gov (United States)

    Lakshmi, Priya Saikumar; Verma, Dheeraj; Yang, Xiangdong; Lloyd, Bethany; Daniell, Henry

    2013-01-01

    Tuberculosis (TB) caused by Mycobacterium tuberculosis is one of the leading fatal infectious diseases. The development of TB vaccines has been recognized as a major public health priority by the World Health Organization. In this study, three candidate antigens, ESAT-6 (6 kDa early secretory antigenic target) and Mtb72F (a fusion polyprotein from two TB antigens, Mtb32 and Mtb39) fused with cholera toxin B-subunit (CTB) and LipY (a cell wall protein) were expressed in tobacco and/or lettuce chloroplasts to facilitate bioencapsulation/oral delivery. Site-specific transgene integration into the chloroplast genome was confirmed by Southern blot analysis. In transplastomic leaves, CTB fusion proteins existed in soluble monomeric or multimeric forms of expected sizes and their expression levels varied depending upon the developmental stage and time of leaf harvest, with the highest-level of accumulation in mature leaves harvested at 6PM. The CTB-ESAT6 and CTB-Mtb72F expression levels reached up to 7.5% and 1.2% of total soluble protein respectively in mature tobacco leaves. Transplastomic CTB-ESAT6 lettuce plants accumulated up to 0.75% of total leaf protein. Western blot analysis of lyophilized lettuce leaves stored at room temperature for up to six months showed that the CTB-ESAT6 fusion protein was stable and preserved proper folding, disulfide bonds and assembly into pentamers for prolonged periods. Also, antigen concentration per gram of leaf tissue was increased 22 fold after lyophilization. Hemolysis assay with purified CTB-ESAT6 protein showed partial hemolysis of red blood cells and confirmed functionality of the ESAT-6 antigen. GM1-binding assay demonstrated that the CTB-ESAT6 fusion protein formed pentamers to bind with the GM1-ganglioside receptor. The expression of functional Mycobacterium tuberculosis antigens in transplastomic plants should facilitate development of a cost-effective and orally deliverable TB booster vaccine with potential for long

  8. Trichinella britovi human infection in Spain : antibody response to surface, excretory/secretory and somatic antigens

    Directory of Open Access Journals (Sweden)

    Rodríguez-Osorio M.

    2003-06-01

    Full Text Available A third outbreak of Trichinella britovi with 140 people involved, occurred in Granada Spain (December 1998. The source of infection was sausage made from uninspected wild boar meat. Fifty-two patients agreed to participated in this study. An elevated eosinophil level (> 5 % was detected in 59.6 % of patients, and persisted in most of these cases for two months. A moderate IgG response was observed. At the onset of symptoms, Western blot (WB test detected more positive cases than Enzyme linked immunosorbent assay (ELISA and indirect immunofluorescence (IIF. Six months from infection, ELISA revealed fewer positive cases than the other two tests. It would appear that the response to somatic antigens starts earlier than those to cuticular and excretory/secretory (ES antigens and that the response to ES antigens is the first to decrease.

  9. Ether lipid vesicle-based antigens impart protection against experimental listeriosis

    Directory of Open Access Journals (Sweden)

    Ansari MA

    2012-06-01

    Full Text Available Mairaj Ahmed Ansari,1 Swaleha Zubair,2 Saba Tufail,1 Ejaj Ahmad,1 Mohsin Raza Khan,1 Zainuddin Quadri,1 Mohammad Owais,11Interdisciplinary Biotechnology Unit, 2Women's College, Aligarh Muslim University, Aligarh, UP, IndiaBackground: Incidence of food-borne infections from Listeria monocytogenes, a parasite that has adapted intracellular residence to avoid antibody onslaught, has increased dramatically in the past few years. The apparent lack of an effective vaccine that is capable of evoking the desired cytotoxic T cell response to obliterate this intracellular pathogen has encouraged the investigation of alternate prophylactic strategies. It should also be noted that Archaebacteria (Archae lipid-based adjuvants enhance the efficacy of subunit vaccines. In the present study, the adjuvant properties of archaeosomes (liposomes prepared from total polar lipids of archaebacteria, Halobacterium salinarum combined with immunogenic culture supernatant antigens of L. monocytogenes have been exploited in designing a vaccine candidate against experimental listeriosis in murine model.Methods: Archaeosome-entrapped secretory protein antigens (SAgs of L. monocytogenes were evaluated for their immunological responses and tendency to deplete bacterial burden in BALB/c mice challenged with sublethal listerial infection. Various immunological studies involving cytokine profiling, lymphocyte proliferation assay, detection of various surface markers (by flowcytometric analysis, and antibody isotypes (by enzyme-linked immunosorbent assay were used for establishing the vaccine potential of archaeosome-entrapped secretory proteins.Results: Immunization schedule involving archaeosome-encapsulated SAgs resulted in upregulation of Th1 cytokine production along with boosted memory in BALB/c mice. It also showed protective effect by reducing listerial burden in various vital organs (liver and spleen of the infected mice. However, the soluble form of the antigens (SAgs

  10. [Comparison of the clinical performance of the ECLusys HIV combi assay with the Lumipulse f and HISCL 2000-i HIV-1/2 ab screening assays].

    Science.gov (United States)

    Sugiura, Aya; Iwahara, Kunihiro; Suga, Yasuyuki; Uchiyama, Sachinori; Maekawa, Masato

    2012-04-01

    We compared the ECLusys HIV combi assay (ECL HIV Ag/Ab) to the Lumipulse Forte (LPf HIV 1/2 Ab) and HISCL (HIS HIV 1/2 Ab) assays. In a dilution sensitivity test using dilution panels of WHO HIV antibody international reference panel (HIV-1 Subtype A, B, C, E, HIV-1 Group O, HIV-2) and HIV-1/2 Ab CE marked material(HIV-1, HIV-2) parent specimens, the ECL assay enabled detection at a higher level of sensitivity than either the LPf assay or the HIS assay for all dilution panels. In an early detection test in the early phase of infection in which a BBI HIV seroconversion panel was used, the ECL assay enabled detection 7 days after initial blood sample collection, whereas the LPf and HIS assays enabled detection after 27 days. In a specificity test using high RF positive specimens (n=33), pregnancy specimens (n=35), cytomegalovirus antibody positive specimens (n=36), and high M protein positive specimens (n=21) that were confirmed negative for HIV-1/2 antibodies by the LPf assay, negative results were obtained for all specimens on both the ECL assay and the HIS assay. In a correlation test using routinely collected clinical specimens (n=121), including positive stock specimens, the ECL and HIS assays demonstrated the highest agreement rate 98.3%. The above results confirmed that the fourth-generation reagent ECL assay, which simultaneously detects both HIV-1/2 antibodies and p24 antigens, is both highly sensitive and specific, and is a suitable assay for use in routine testing.

  11. Enzyme-Linked Immunosorbent Assays for Detection of Equine Antibodies Specific to Sarcocystis neurona Surface Antigens†

    Science.gov (United States)

    Hoane, Jessica S.; Morrow, Jennifer K.; Saville, William J.; Dubey, J. P.; Granstrom, David E.; Howe, Daniel K.

    2005-01-01

    Sarcocystis neurona is the primary causative agent of equine protozoal myeloencephalitis (EPM), a common neurologic disease of horses in the Americas. We have developed a set of enzyme-linked immunosorbent assays (ELISAs) based on the four major surface antigens of S. neurona (SnSAGs) to analyze the equine antibody response to S. neurona. The SnSAG ELISAs were optimized and standardized with a sample set of 36 equine sera that had been characterized by Western blotting against total S. neurona parasite antigen, the current gold standard for S. neurona serology. The recombinant SnSAG2 (rSnSAG2) ELISA showed the highest sensitivity and specificity at 95.5% and 92.9%, respectively. In contrast, only 68.2% sensitivity and 71.4% specificity were achieved with the rSnSAG1 ELISA, indicating that this antigen may not be a reliable serological marker for analyzing antibodies against S. neurona in horses. Importantly, the ELISA antigens did not show cross-reactivity with antisera to Sarcocystis fayeri or Neospora hughesi, two other equine parasites. The accuracy and reliability exhibited by the SnSAG ELISAs suggest that these assays will be valuable tools for examining the equine immune response against S. neurona infection, which may help in understanding the pathobiology of this accidental parasite-host interaction. Moreover, with modification and further investigation, the SnSAG ELISAs have potential for use as immunodiagnostic tests to aid in the identification of horses affected by EPM. PMID:16148170

  12. Label-free quantitative mass spectrometry for analysis of protein antigens in a meningococcal group B outer membrane vesicle vaccine.

    Science.gov (United States)

    Dick, Lawrence W; Mehl, John T; Loughney, John W; Mach, Anna; Rustandi, Richard R; Ha, Sha; Zhang, Lan; Przysiecki, Craig T; Dieter, Lance; Hoang, Van M

    2015-01-01

    The development of a multivalent outer membrane vesicle (OMV) vaccine where each strain contributes multiple key protein antigens presents numerous analytical challenges. One major difficulty is the ability to accurately and specifically quantitate each antigen, especially during early development and process optimization when immunoreagents are limited or unavailable. To overcome this problem, quantitative mass spectrometry methods can be used. In place of traditional mass assays such as enzyme-linked immunosorbent assays (ELISAs), quantitative LC-MS/MS using multiple reaction monitoring (MRM) can be used during early-phase process development to measure key protein components in complex vaccines in the absence of specific immunoreagents. Multiplexed, label-free quantitative mass spectrometry methods using protein extraction by either detergent or 2-phase solvent were developed to quantitate levels of several meningococcal serogroup B protein antigens in an OMV vaccine candidate. Precision was demonstrated to be less than 15% RSD for the 2-phase extraction and less than 10% RSD for the detergent extraction method. Accuracy was 70 to 130% for the method using a 2-phase extraction and 90-110% for detergent extraction. The viability of MS-based protein quantification as a vaccine characterization method was demonstrated and advantages over traditional quantitative methods were evaluated. Implementation of these MS-based quantification methods can help to decrease the development time for complex vaccines and can provide orthogonal confirmation of results from existing antigen quantification techniques.

  13. The clinical study of serum PSA and fPSA assayed by CLIA in diagnosing prostate disease

    International Nuclear Information System (INIS)

    Xiong Jiang; Qian Xiaoyu; Ji Hong; Yang Su; Ding Ying; Zhu Ruisen; Chen Zhong

    2003-01-01

    The purpose of this study is to evaluate the clinical value of PSA (prostate specific antigen) and fPSA(free prostate specific antigen) in differentiating prostate disease. CLIA was used to quantitatively assay PSA, fPSA and fPSA/PSA in 30 cases of normal controls, 32 cases of prostate cancer patients and 76 cases of BPH patients. The result showed that if liminal value of PSA was set at 4 ng/mL, the diagnostic sensitivity and specificity of prostate cancer were 100% and 50.6% respectively. Meanwhile, if liminal value of fPSA/PSA set at 16% was added, the diagnostic sensitivity and specificity of prostate cancer were 100% and 85.3% respectively. It was concluded that the combining assay of PSA and fPSA could increase the diagnostic specificity of prostate cancer in a certain degree

  14. A multicenter evaluation of the Biotest legionella urinary antigen EIA

    DEFF Research Database (Denmark)

    Harrison, Timothy; Uldum, Søren; Alexiou-Daniel, Stella

    1998-01-01

    OBJECTIVES: To undertake a multicenter study to evaluate the Biotest legionella urinary antigen enzyme immunoassay (EIA) performance against those EIAs already in use in 14 European laboratories. METHODS: Each laboratory examined urine specimens from appropriate patients using both their current...... assay and the Biotest EIA. Each examined: a standard panel of 12 coded urine samples (distributed by Biotest); a panel of 10 coded urine samples provided as part of a European external quality assurance (EQA) scheme; urine samples from patients with proven legionnaires' disease (LD); urine samples from...... patients with pneumonia of microbiologically proven cause other than LD; and urine samples submitted for routine examination. Thus, the performance of the Biotest assay (in comparison with current EIAs), its specificity and utility, and the inter-laboratory agreement were assessed. RESULTS: Inter...

  15. Diagnosis of selected tropical diseases (Shistosomiasis and Malaria) using the enzyme-linked immunosorbent assays

    International Nuclear Information System (INIS)

    Chembe, E.

    1985-01-01

    Immunological reactions are commonly used in diagnostic procedures on the basis of their high levels of specificity and sensitivity. Antibodies or antigens labelled with various markers have been found to be particularly useful for assays of logical substances. The applications of Enzyme-Linked Immunoabsorbent Assays (ELISA) to research on various tropical and non-tropical diseases is now well established. The procedure depends on the labelling of one of the reactants with enzymes which can be detected accurately by an appropriate substrate. The detection mechanism depends on the labelling of one of the reactants in such a way that their their reactivity is not impaired or affected. In the present study, ELISA was applied to sera from kampumbu area of Isoka district in the Northern province of Zambia. The objective of this presentation is to show the relative positivity rate for antigen and antibody and the endemicity of schistosomiasis and malaria as assessed by classical parasitological procedures. (author)

  16. Role of interleukin-1 in antigen presentation by normal articular chondrocytes

    International Nuclear Information System (INIS)

    Tiku, M.L.; Liu, S.; Tiku, K.

    1986-01-01

    Recently the authors have described that normal articular chondrocytes of rabbits present antigen to immune T cells. In the present study the authors investigated the role of interleukin-1 (IL-1) on antigen presentation by chondrocytes. For these experiments the antigen pulsed chondroyctes were either untreated or fixed with paraformaldehyde and then co-cultured with immune T cells. T cell proliferation was measured by 3 H-thymidine incorporation. Pulsed non-fixed chondrocytes presented antigen, as expected, but pulsed and fixed cells failed to present antigen to T cells. The 3 H-TdR incorporation was partially restored by addition of purified human IL-1. Next, IL-1 activity was measured in primary chondrocyte culture supernatants stimulated with or without lipopolysaccharide (LPS) in comitogen thymocyte assay. No activity was detected in chondrocyte supernatants. Propagated chondrocyte culture supernatants also lacked IL-1 activity when stimulated with LPS in the presence of increasing concentration of indomethacin. On the other hand the authors observed that chondrocyte culture supernatants in a dose dependent manner inhibited human IL-1 induced 3 H-TdR incorporation of murine thymocytes. This suggested that these cells may produce an inhibitor of IL-1 and IL-1 production by chondrocytes may be essential for T cell proliferation by these cells. Inability to detect IL-1 in chondrocyte supernatants may be due to the presence of an inhibitor to IL-1. These findings may help in elucidating the immunological mechanisms in situations where chondrocytes and T cell interact, such as in arthritis

  17. Improvement of an enzyme-linked immunosorbent assay for equine herpesvirus type 4 by using a synthetic-peptide 24-mer repeat sequence of glycoprotein G as an antigen

    Science.gov (United States)

    BANNAI, Hiroshi; NEMOTO, Manabu; TSUJIMURA, Koji; YAMANAKA, Takashi; MAEDA, Ken; KONDO, Takashi

    2015-01-01

    To increase the sensitivity of an enzyme-linked immunosorbent assay (ELISA) for equine herpesvirus type 4 (EHV-4) that uses a 12-mer peptide of glycoprotein G (gG4-12-mer: MKNNPIYSEGSL) [4], we used a longer peptide consisting of a 24-mer repeat sequence (gG4-24-mer: MKNNPIYSEGSLMLNVQHDDSIHT) as an antigen. Sera of horses experimentally infected with EHV-4 reacted much more strongly to the gG4-24-mer peptide than to the gG4-12-mer peptide. We used peptide ELISAs to test paired sera from horses naturally infected with EHV-4 (n=40). gG4-24-mer ELISA detected 37 positive samples (92.5%), whereas gG4-12-mer ELISA detected only 28 (70.0%). gG4-24-mer ELISA was much more sensitive than gG4-12-mer ELISA. PMID:26424485

  18. Use of hydrophilic extra-viral domain of canine distemper virus H protein for enzyme-linked immunosorbent assay development.

    Science.gov (United States)

    Cho, Ki-hyun; Kim, Jeongmi; Yoo, Hyun-ah; Kim, Dae-hee; Park, Seung-yong; Song, Chang-seon; Choi, In-soo; Lee, Joong-bok

    2014-12-01

    Simple methods for measuring the levels of serum antibody against canine distemper virus (CDV) would assist in the effective vaccination of dogs. To develop an enzyme-linked immunosorbent assay (ELISA) specific for CDV, we expressed hydrophilic extra-viral domain (HEVD) protein of the A75/17-CDV H gene in a pET 28a plasmid-based Escherichia (E.) coli vector system. Expression was confirmed by dot and Western blotting. We proposed that detection of E. coli-expressed H protein might be conformation- dependent because intensities of the reactions observed with these two methods varied. The H gene HEVD protein was further purified and used as an antigen for an ELISA. Samples from dogs with undetectable to high anti-CDV antibody titers were analyzed using this HEVD-specific ELISA and a commercial CDV antibody detection kit (ImmunoComb). Levels of HEVD antigenicity measured with the assays and immunochromatography correlated. These data indicated that the HEDV protein may be used as antigen to develop techniques for detecting antibodies against CDV.

  19. Expression and Antigenic Evaluation of VacA Antigenic Fragment of Helicobacter Pylori

    Science.gov (United States)

    Hasanzadeh, Leila; Ghaznavi-Rad, Ehsanollah; Soufian, Safieh; Farjadi, Vahideh; Abtahi, Hamid

    2013-01-01

    Objective(s) : Helicobacter pylori, a human specific gastric pathogen is a causative agent of chronic active gastritis. The vacuolating cytotoxin (VacA) is an effective virulence factor involved in gastric injury. The aim of this study was to construct a recombinant protein containing antigenic region of VacA gene and determine its antigenicity. Materials and Methods: The antigenic region of VacA gene was detected by bioinformatics methods. The polymerase chain reaction method was used to amplify a highly antigenic region of VacA gene from chromosomal DNA of H. pylori. The eluted product was cloned into the prokaryotic expression vector pET32a. The target protein was expressed in the Escherichia coli BL21 (DE3) pLysS. The bacteria including pET32a-VacA plasmids were induced by IPTG. The antigenicity was finally studied by western blotting using sera of 15 H. pylori infected patients after purification. Results: Enzyme digestion analysis, PCR and DNA sequencing results showed that the target gene was inserted correctly into the recombinant vector. The expressed protein was purified successfully via affinity chromatography. Data indicated that antigenic region of VacA protein from Helicobacter pylori was recognized by all 15 patient’s sera. Conclusion : Our data showed that antigenic region of VacA protein can be expressed by in E. co.li. This protein was recognized by sera patients suffering from H. pylori infection. the recombinant protein has similar epitopes and close antigenic properties to the natural form of this antigen. Recombinant antigenic region of VacA protein also seems to be a promising antigen for protective and serologic diagnosis . PMID:23997913

  20. Expression and Antigenic Evaluation of VacA Antigenic Fragment of Helicobacter Pylori

    Directory of Open Access Journals (Sweden)

    Leila Hasanzadeh

    2013-07-01

    Full Text Available Objective(s: Helicobacter pylori, a human specific gastric pathogen is a causative agent of chronic active gastritis. The vacuolating cytotoxin (VacA is an effective virulence factor involved in gastric injury. The aim of this study was to construct a recombinant protein containing antigenic region of VacA gene and determine its antigenicity.   Materials and Methods: The antigenic region of VacA gene was detected by bioinformatics methods. The polymerase chain reaction method was used to amplify a highly antigenic region of VacA gene from chromosomal DNA of H. pylori. The eluted product was cloned into the prokaryotic expression vector pET32a. The target protein was expressed in the Escherichia coli BL21 (DE3 pLysS. The bacteria including pET32a-VacA plasmids were induced by IPTG. The antigenicity was finally studied by western blotting using sera of 15 H. pylori infected patients after purification. Results: Enzyme digestion analysis, PCR and DNA sequencing results showed that the target gene was inserted correctly into the recombinant vector. The expressed protein was purified successfully via affinity chromatography. Data indicated that antigenic region of VacA protein from Helicobacter pylori was recognized by all 15 patient’s sera. Conclusion : Our data showed that antigenic region of VacA protein can be expressed by in E. co.li. This protein was recognized by sera patients suffering from H. pylori infection. the recombinant protein has similar epitopes and close antigenic properties to the natural form of this antigen. Recombinant antigenic region of VacA protein also seems to be a promising antigen for protective and serologic diagnosis .

  1. Reduced Serum IgG Responses to Pneumococcal Antigens in Otitis-Prone Children May Be Due to Poor Memory B-Cell Generation

    Science.gov (United States)

    Sharma, Sharad K.; Casey, Janet R.

    2012-01-01

    A low level of serum antibody to antigens expressed by Streptococcus pneumoniae has been proposed to explain the susceptibility of children to recurrent episodes of acute otitis media (hereafter, “otitis-prone children”). By use of enzyme-linked immunospot assays, the percentages of memory B cells to pneumococcal protein antigens PhtD, LytB, PcpA, PhtE, and Ply were compared between otitis-prone and non–otitis-prone children at the time of acute otitis media or nasopharyngeal colonization with S. pneumoniae. We found significantly lower percentages of memory B cells to 3 pneumococcal protein antigens (PhtD, PhtE, and Ply) and reduced antigen-specific immunoglobulin G concentrations in otitis-prone children, compared with non–otitis-prone children. PMID:22383675

  2. Identification of immunogenic Salmonella enterica serotype Typhi antigens expressed in chronic biliary carriers of S. Typhi in Kathmandu, Nepal.

    Directory of Open Access Journals (Sweden)

    Richelle C Charles

    Full Text Available Salmonella enterica serotype Typhi can colonize and persist in the biliary tract of infected individuals, resulting in a state of asymptomatic chronic carriage. Chronic carriers may act as persistent reservoirs of infection within a community and may introduce infection to susceptible individuals and new communities. Little is known about the interaction between the host and pathogen in the biliary tract of chronic carriers, and there is currently no reliable diagnostic assay to identify asymptomatic S. Typhi carriage.To study host-pathogen interactions in the biliary tract during S. Typhi carriage, we applied an immunoscreening technique called in vivo-induced antigen technology (IVIAT, to identify potential biomarkers unique to carriers. IVIAT identifies humorally immunogenic bacterial antigens expressed uniquely in the in vivo environment, and we hypothesized that S. Typhi surviving in the biliary tract of humans may express a distinct antigenic profile. Thirteen S. Typhi antigens that were immunoreactive in carriers, but not in healthy individuals from a typhoid endemic area, were identified. The identified antigens included a number of putative membrane proteins, lipoproteins, and hemolysin-related proteins. YncE (STY1479, an uncharacterized protein with an ATP-binding motif, gave prominent responses in our screen. The response to YncE in patients whose biliary tract contained S. Typhi was compared to responses in patients whose biliary tract did not contain S. Typhi, patients with acute typhoid fever, and healthy controls residing in a typhoid endemic area. Seven of 10 (70% chronic carriers, 0 of 8 bile culture-negative controls (0%, 0 of 8 healthy Bangladeshis (0%, and 1 of 8 (12.5% Bangladeshis with acute typhoid fever had detectable anti-YncE IgG in blood. IgA responses were also present.Further evaluation of YncE and other antigens identified by IVIAT could lead to the development of improved diagnostic assays to identify asymptomatic

  3. Immunological measurements on the disappearance of creatine kinase MM from the circulation. [Immunoradiometric assay

    Energy Technology Data Exchange (ETDEWEB)

    Wevers, R A; van Landeghem, A A.J.; Mul-Steinbusch, M W.F.J.; Bijdendijk, J G; Weerts, P; Kloeg, P; Soons, J B.J. [Rijksuniversiteit Utrecht (Netherlands)

    1983-07-15

    Both a two-site immunoradiometric assay and a two-site enzyme-linked immunosorbent assay for creatine kinase MM are described. Linearity, reproducibility and cross-reactivity of the assays are satisfactory. Creatine kinase MM incubated in a pH-controlled serum matrix loses its activity, but has its antigenic determinants affected as well. Of all the techniques used, only the immunoradiometric assay is capable of measuring part of the inactivated enzyme. Measurements with this assay on the sera of patients after a myocardial infarction show identical results for enzyme activity and creatine kinase protein quantity. The in vitro disappearance rate of creatine kinase activity is slow compared with the in vivo half-life of the enzyme. These two observations lead to the conclusion that creatine kinase is removed from the circulation long before it is inactivated in the blood stream.

  4. Humoral immunity to memory antigens and pathogens is maintained in patients with chronic kidney disease.

    Science.gov (United States)

    Wall, Nadezhda A; Dominguez-Medina, C Coral; Faustini, Sian E; Cook, Charlotte N; McClean, Andrew; Jesky, Mark D; Perez-Toledo, Marisol; Morgan, Matthew D; Richter, Alexandra G; Ferro, Charles J; Cockwell, Paul; Moss, Paul A; Henderson, Ian R; Harper, Lorraine; Cunningham, Adam F

    2018-01-01

    Patients with chronic kidney disease (CKD) have an increased risk of infection and poorer responses to vaccination. This suggests that CKD patients have an impaired responsiveness to all antigens, even those first encountered before CKD onset. To examine this we evaluated antibody responses against two childhood vaccine antigens, tetanus (TT) and diphtheria toxoids (DT) and two common pathogens, cytomegalovirus (CMV) and Salmonella enterica serovar Enteritidis (SEn) in two independent cohorts consisting of age-matched individuals with and without CKD. Sera were evaluated for antigen-specific IgG titres and the functionality of antibody to SEn was assessed in a serum bactericidal assay. Surprisingly, patients with CKD and control subjects had comparable levels of IgG against TT and DT, suggesting preserved humoral memory responses to antigens encountered early in life. Lipopolysaccharide-specific IgG titres and serum bactericidal activity in patients with CKD were also not inferior to controls. CMV-specific IgG titres in seropositive CKD patients were similar or even increased compared to controls. Therefore, whilst responses to new vaccines in CKD are typically lower than expected, antibody responses to antigens commonly encountered prior to CKD onset are not. The immunodeficiency of CKD is likely characterised by failure to respond to new antigenic challenges and efforts to improve patient outcomes should be focussed here.

  5. Heterophilic interference in specimens yielding false-reactive results on the Abbott 4th generation ARCHITECT HIV Ag/Ab Combo assay.

    Science.gov (United States)

    Lavoie, S; Caswell, D; Gill, M J; Kadkhoda, K; Charlton, C L; Levett, P N; Hatchette, T; Garceau, R; Maregmen, J; Mazzulli, T; Needle, R; Kadivar, K; Kim, J

    2018-04-12

    False-reactivity in HIV-negative specimens has been detected in HIV fourth-generation antigen/antibody or 'combo' assays which are able to detect both anti-HIV-1/HIV-2 antibodies and HIV-1 antigen. We sought to characterize these specimens and determine the effect of heterophilic interference. Specimens previously testing as false-reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay and re-tested on a different (Siemens ADVIA Centaur HIV Ag/Ab) assay. A subset of these specimens were also pre-treated with heterophilic blocking agents and re-tested on the Abbott assay. Here we report that 95% (252/264) of clinical specimens that were repeatedly reactive on the Abbott ARCHITECT HIV Ag/Ab combo assay (S/Co range, 0.94-678) were negative when re-tested on a different fourth generation HIV combo assay (Siemens ADVIA Centaur HIV Ag/Ab). All 264 samples were subsequently confirmed to be HIV negative. On a small subset (57) of specimens with available volume, pre-treatment with two different reagents (HBT; Heterophilic Blocking Tube, NABT; Non-Specific Blocking Tube) designed to block heterophilic antibody interference either eliminated (HBT) or reduced (NABT) the false reactivity when re-tested on the ARCHITECT HIV Ag/Ab combo assay. Our results suggest that the Abbott ARCHITECT HIV Ag/Ab combo assay can be prone to heterophilic antibody interference. Crown Copyright © 2018. Published by Elsevier B.V. All rights reserved.

  6. Significance of Serology by Multi-Antigen ELISA for Tissue Helminthiases in Korea

    Science.gov (United States)

    2017-01-01

    It is clinically important to differentiate tissue-invading helminthiasis. The purpose of this study was to assess the specific immunoglobulin G (IgG) antibody positive rates for clonorchiasis, paragonimiasis, cysticercosis, and sparganosis 4 helminthiases from 1996 to 2006 using multi-antigen enzyme-linked immunosorbent assay (ELISA) in Korea. Results of 6,017 samples, which were referred to our institute for serodiagnosis, were analyzed. The subjects with positive serum IgG antibodies were 1,502 (25.0%) for any of the 4 helminthiases. The overall positive numbers for clonorchiasis, paragonimiasis, cysticercosis, and sparganosis were 728 (12.1%), 166 (2.8%), 729 (12.1%), and 263 (4.4%), respectively. The positive serologic reaction to multi-antigens was determined in 309 (20.6%) of the 1,502 total seropositive subjects. Those with multi-antigen positivity were regarded as positive for the antigen of strongest reaction but cross-reaction to others with weak positive reaction. Annual seropositive rates for those 4 tissue helminthiases ranged from 12.1% to 35.7%. The highest rate was observed in age from 60 to 69 years old and prevalence of men (27.4%; 1,030/3,763) was significantly higher than of women (19.1%; 332/1,741). Hospital records of 165 ELISA positive patients were reviewed to confirm correlation with their clinical diagnosis. Paragonimiasis was highly correlated as 81.8% (9/11), cysticercosis 29.9% (20/67), clonorchiasis 29.0% (20/69), and sparganosis 11.1% (2/18). In conclusion, the multi-antigen ELISA using 4 helminth antigens is useful to differentiate suspected tissue-invading helminthiases, especially ELISA diagnosis of paragonimiasis is reliable. The seropositivity is still high among suspected patients in Korea. PMID:28581268

  7. Development of versatile universal reagent immunoradiometric assay technique

    International Nuclear Information System (INIS)

    Hazra, D.K.

    1982-10-01

    Immunoradiometric assays, which make use of labelled antibodies, potentially offer better sensitivity and specificity than do radioimmunoassays, which use labelled antigens. In addition, they can in principle be performed in a particularly convenient scheme wherein the same labelled reagent may be used for many different analytes - thus serving as a ''universal'' labelled reagent. Thus if the specific antibody for every analyte is raised in rabbits, and an anti-rabbit antibody is labelled, the latter may be added after the specific antibody to quantify the amount of specific antibody bound to analyte and thereby the amount of analyte present. The potential greater sensitivity and specificity of the immunoradiometric procedure, coupled with the potential convenience of the ''universal'' labelled reagent, might allow such immunoradiometric techniques to be used effectively in the study of communicable diseases in developing countries. Development of these procedures was the subject of this investigation. Many components of these procedures had to be explored and provisionally optimized, including coating of assay tubes with ''extraction'' antibody, immunological purification of antibodies, labelling of antibodies, and intermediate steps toward these goals. Applications were thereupon tested using those provisionally optimized components. The ''universal'' labelled reagent, a donkey anti-rabbit antiserum, was successfully used in the assay of TSH; however, cross reactions of the reagent with non-rabbit immunoglobulins and other materials present seriously limited the sensitivity of the method. Using conventional immunoradiometric procedures, circulating TB and amoebic antibodies could be detected in patients suffering from these diseases. Similarly, circulating antigens in the same patients could also be detected, but not with sufficient sensitivity and specificity to provide a reliable analytical system. Numerous improvements will be required before these techniques

  8. Demonstration of feline corona virus (FCV) antigen in organs of cats suspected of feline infectious peritonitis (FIP) disease.

    Science.gov (United States)

    Hök, K

    1990-07-01

    Cryosections of organs and smears from membrana nicitians from cats suspected of having spontaneous infection with feline infectious peritonitis virus (FIPV), were investigated using an indirect immunofluorescence assay (IIFA) in order to detect the presence of feline corona virus (FCV). In 113 cats, from each of which six organs were screened, virus antigen was found most often in membrana nicitians and lung. Out of these animals an additional six organs from a group of 30 cats were screened. In these cats membrana nicitians, parotid gland, thymus and apex of caecum had the highest incidence of virus antigen (90%). The lowest incidence of virus antigen was found in the spleen (60%). There was a clear demonstration of a higher incidence of antigen present in more than half of the total number of screened organs per cat (P less than 0.0005). No statistical difference was observed between sexes when comparing the incidence of virus antigen in different organs. Virus antigen was present in less organs in cats with no lesions suggestive of FIP disease compared to cats with such lesions (P less than 0.001). A similar distribution of the incidence of FCV antigen in the investigated organs was observed in these two groups.

  9. Rapid detection of EBOLA VP40 in microchip immunofiltration assay

    Science.gov (United States)

    Miethe, Peter; Gary, Dominik; Hlawatsch, Nadine; Gad, Anne-Marie

    2015-05-01

    In the spring of 2014, the Ebola virus (EBOV) strain Zaire caused a dramatic outbreak in several regions of West Africa. The RT-PCR and antigen capture diagnostic proved to be effective for detecting EBOV in blood and serum. In this paper, we present data of a rapid antigen capture test for the detection of VP40. The test was performed in a microfluidic chip for immunofiltration analysis. The chip integrates all necessary assay components. The analytical sensitivity of the rapid test was 8 ng/ml for recombinant VP40. In serum and whole blood samples spiked with virus culture material, the detection limit was 2.2 x 102 PFU/ml. The performance data of the rapid test (15 min) are comparable to that of the VP40 laboratory ELISA.

  10. Detection of serum anti-sperm antibody in infertile couples with dot-immunogold filtration assay (DIGFA)

    International Nuclear Information System (INIS)

    Xie Xiaoxian

    2005-01-01

    Objective: To develop a new method for rapid detection of serum anti-sperm antibody in infertile couples. Methods: Human sperm antigen was prepared from pooled semen specimens of fertile males. Nitro-cellulose membrane was used as solid-phase carrier of the antigen. Colloidal gold pellet combined goat anti-human IgG was taken as labelled antibody. A dot-immunogold filtration assay system was established for test of serum anti-human sperm antibody. Serum specimens from 137 infertile couples were tested and the result compared with flat from ELISA. Results: The human sperm antigen would react with the anti-sperm antibody in the tested serum over the cellulose membrane through filtration and the result could be read with naked eye within 6 minutes. In this study of 137 infertile coupled, the anti-sperm antibody was positive in 21.9% of the female serum specimens and 13.19% of the males. Compared with the result from ELISA, the consistency rate was 96.1%. The sensitivity of the assay was 90.2% and specificity was 95.4%. The p reparation was stable after 6 months refrigerator storage. Conclusion: This newly developed DIGFA is very adequate for rap id detection of anti-sperm antibody and deserves popularization. (authors)

  11. Evaluation of a CLEIA automated assay system for the detection of a panel of tumor markers.

    Science.gov (United States)

    Falzarano, Renato; Viggiani, Valentina; Michienzi, Simona; Longo, Flavia; Tudini, Silvestra; Frati, Luigi; Anastasi, Emanuela

    2013-10-01

    Tumor markers are commonly used to detect a relapse of disease in oncologic patients during follow-up. It is important to evaluate new assay systems for a better and more precise assessment, as a standardized method is currently lacking. The aim of this study was to assess the concordance between an automated chemiluminescent enzyme immunoassay system (LUMIPULSE® G1200) and our reference methods using seven tumor markers. Serum samples from 787 subjects representing a variety of diagnoses, including oncologic, were analyzed using LUMIPULSE® G1200 and our reference methods. Serum values were measured for the following analytes: prostate-specific antigen (PSA), alpha-fetoprotein (AFP), carcinoembryonic antigen (CEA), cancer antigen 125 (CA125), carbohydrate antigen 15-3 (CA15-3), carbohydrate antigen 19-9 (CA19-9), and cytokeratin 19 fragment (CYFRA 21-1). For the determination of CEA, AFP, and PSA, an automatic analyzer based on chemiluminescence was applied as reference method. To assess CYFRA 21-1, CA125, CA19-9, and CA15-3, an immunoradiometric manual system was employed. Method comparison by Passing-Bablok analysis resulted in slopes ranging from 0.9728 to 1.9089 and correlation coefficients from 0.9977 to 0.9335. The precision of each assay was assessed by testing six serum samples. Each sample was analyzed for all tumor biomarkers in duplicate and in three different runs. The coefficients of variation were less than 6.3 and 6.2 % for within-run and between-run variation, respectively. Our data suggest an overall good interassay agreement for all markers. The comparison with our reference methods showed good precision and reliability, highlighting its usefulness in clinical laboratory's routine.

  12. Monoclonal antibodies for use in an immunoradiometric assay for α-foetoprotein

    International Nuclear Information System (INIS)

    Hunter, W.M.; Bennie, J.G.

    1982-01-01

    The advantages offered by a mouse IgG 1 monoclonal antibody to human α-foetoprotein (AFP) for the preparation of [ 125 I]antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom 125 I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added [ 125 ]Ab was present in the sandwich. Linear response curves in the range 1-100 μg antigen/l incubate were obtained when [ 125 I]Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently 125 I]Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the [ 125 I]monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system. (Auth.)

  13. Comparison of Five Assays for Detection of Clostridium difficile Toxin

    Science.gov (United States)

    Chapin, Kimberle C.; Dickenson, Roberta A.; Wu, Fongman; Andrea, Sarah B.

    2011-01-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. PMID:21704273

  14. Prevalence of human immunodeficiency virus type 1 p24 antigen in U.S. blood donors--an assessment of the efficacy of testing in donor screening. The HIV-Antigen Study Group.

    Science.gov (United States)

    Alter, H J; Epstein, J S; Swenson, S G; VanRaden, M J; Ward, J W; Kaslow, R A; Menitove, J E; Klein, H G; Sandler, S G; Sayers, M H

    1990-11-08

    We performed a multicenter study in 1989 to determine whether screening whole-blood donors for human immunodeficiency virus type 1 (HIV-1) p24 antigen would improve transfusion safety by identifying carriers of the virus who are seronegative for HIV-1 antibody. More than 500,000 donations were tested at 13 U.S. blood centers with test kits from two manufacturers. Units found repeatedly reactive were retested in a central laboratory; if the results were positive, they were confirmed by a neutralization assay. A subgroup of units was also tested for HIV-1 by the polymerase chain reaction. Selected donors confirmed or not confirmed as having p24 antigen were contacted for follow-up interviews to identify risk factors and undergo retesting for HIV-1 markers. Positive tests for p24 antigen were confirmed by neutralization in five donors (0.001 percent of all donations tested), all of whom were also positive for HIV-1 antibody and HIV-1 by polymerase chain reaction. Three of the antigen-positive donors had other markers of infectious disease that would have resulted in the exclusion of their blood; two had risk factors for HIV-1 that should have led to self-exclusion. Of 220 blood units with repeatedly reactive p24 antigen whose presence could not be confirmed by neutralization (0.04 percent of the donations studied), none were positive for HIV-1 antibody, HIV-1 by polymerase chain reaction (120 units tested), or virus culture (76 units tested)--attesting to the specificity of confirmatory neutralization. The finding that no donation studied was positive for p24 antigen and negative for HIV-1 antibody suggests that screening donors for p24 antigen with tests of the current level of sensitivity would not add substantially to the safety of the U.S. blood supply.

  15. A two-step lyssavirus real-time polymerase chain reaction using degenerate primers with superior sensitivity to the fluorescent antigen test.

    Science.gov (United States)

    Suin, Vanessa; Nazé, Florence; Francart, Aurélie; Lamoral, Sophie; De Craeye, Stéphane; Kalai, Michael; Van Gucht, Steven

    2014-01-01

    A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR), based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤ 1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.

  16. Hierarchical Bayesian mixture modelling for antigen-specific T-cell subtyping in combinatorially encoded flow cytometry studies

    DEFF Research Database (Denmark)

    Lin, Lin; Chan, Cliburn; Hadrup, Sine R

    2013-01-01

    subtype identification in this novel, general model framework, and provide a detailed example using simulated data. We then describe application to a data set from an experimental study of antigen-specific T-cell subtyping using combinatorially encoded assays in human blood samples. Summary comments...... profiling in many biological areas, traditional flow cytometry measures relative levels of abundance of marker proteins using fluorescently labeled tags that identify specific markers by a single-color. One specific and important recent development in this area is the use of combinatorial marker assays...

  17. [Expression changes of major outer membrane protein antigens in Leptospira interrogans during infection and its mechanism].

    Science.gov (United States)

    Zheng, Linli; Ge, Yumei; Hu, Weilin; Yan, Jie

    2013-03-01

    To determine expression changes of major outer membrane protein(OMP) antigens of Leptospira interrogans serogroup Icterohaemorrhagiae serovar Lai strain Lai during infection of human macrophages and its mechanism. OmpR encoding genes and OmpR-related histidine kinase (HK) encoding gene of L.interrogans strain Lai and their functional domains were predicted using bioinformatics technique. mRNA level changes of the leptospiral major OMP-encoding genes before and after infection of human THP-1 macrophages were detected by real-time fluorescence quantitative RT-PCR. Effects of the OmpR-encoding genes and HK-encoding gene on the expression of leptospiral OMPs during infection were determined by HK-peptide antiserum block assay and closantel inhibitive assays. The bioinformatics analysis indicated that LB015 and LB333 were referred to OmpR-encoding genes of the spirochete, while LB014 might act as a OmpR-related HK-encoding gene. After the spirochete infecting THP-1 cells, mRNA levels of leptospiral lipL21, lipL32 and lipL41 genes were rapidly and persistently down-regulated (P Expression levels of L.interrogans strain Lai major OMP antigens present notable changes during infection of human macrophages. There is a group of OmpR-and HK-encoding genes which may play a major role in down-regulation of expression levels of partial OMP antigens during infection.

  18. Serological Assays Based on Recombinant Viral Proteins for the Diagnosis of Arenavirus Hemorrhagic Fevers

    Directory of Open Access Journals (Sweden)

    Masayuki Saijo

    2012-10-01

    Full Text Available The family Arenaviridae, genus Arenavirus, consists of two phylogenetically independent groups: Old World (OW and New World (NW complexes. The Lassa and Lujo viruses in the OW complex and the Guanarito, Junin, Machupo, Sabia, and Chapare viruses in the NW complex cause viral hemorrhagic fever (VHF in humans, leading to serious public health concerns. These viruses are also considered potential bioterrorism agents. Therefore, it is of great importance to detect these pathogens rapidly and specifically in order to minimize the risk and scale of arenavirus outbreaks. However, these arenaviruses are classified as BSL-4 pathogens, thus making it difficult to develop diagnostic techniques for these virus infections in institutes without BSL-4 facilities. To overcome these difficulties, antibody detection systems in the form of an enzyme-linked immunosorbent assay (ELISA and an indirect immunofluorescence assay were developed using recombinant nucleoproteins (rNPs derived from these viruses. Furthermore, several antigen-detection assays were developed. For example, novel monoclonal antibodies (mAbs to the rNPs of Lassa and Junin viruses were generated. Sandwich antigen-capture (Ag-capture ELISAs using these mAbs as capture antibodies were developed and confirmed to be sensitive and specific for detecting the respective arenavirus NPs. These rNP-based assays were proposed to be useful not only for an etiological diagnosis of VHFs, but also for seroepidemiological studies on VHFs. We recently developed arenavirus neutralization assays using vesicular stomatitis virus (VSV-based pseudotypes bearing arenavirus recombinant glycoproteins. The goal of this article is to review the recent advances in developing laboratory diagnostic assays based on recombinant viral proteins for the diagnosis of VHFs and epidemiological studies on the VHFs caused by arenaviruses.

  19. Heparin-associated thrombocytopenia: antibody binding specificity to platelet antigens.

    Science.gov (United States)

    Lynch, D M; Howe, S E

    1985-11-01

    Sera from four patients with heparin-associated thrombocytopenia (HAT) were evaluated by a quantitative enzyme-linked immunosorbent assay (ELISA) to detect heparin-dependent serum platelet-bindable immunoglobulin (S-PBIg) and by Western blotting and immunoprecipitation to investigate the specificity of the antibody binding. All HAT sera showed mildly increased S-PBIg (mean, 7.8 fg per platelet; normal, less than 6.0 fg per platelet) to intact target platelets in the ELISA, which was markedly increased in the presence of heparin (mean, 20.9 fg per platelet). This increase was 20-fold greater than normal control sera, which showed a mean differential increase of only 0.5 fg per platelet. Immunoglobulin binding specificity to platelet antigens was investigated using sodium dodecyl sulfate-polyacrylamide gel electrophoresis of platelet lysate with transfer of the platelet fractions onto nitrocellulose strips (Western blotting) and subsequent immunoassay using HAT and normal sera. In the presence of heparin, the four HAT patients demonstrated increased binding of immunoglobulin to platelet antigens of apparent molecular weights of 180, 124, and 82 kd. Radiolabeled heparin when incubated with HAT sera, normal sera, or albumin blanks bound to platelet proteins of the same apparent molecular weights. These observations are consistent with current hypotheses suggesting that HAT antibody is directed to heparin-platelet complexes or, alternatively, that heparin induces conformational change of antigenic sites on the platelet membrane.

  20. Immunodetection of Fasciola gigantica Circulating Antigen in Sera of Infected Individuals for Laboratory Diagnosis of Human Fascioliasis

    Science.gov (United States)

    Attallah, Abdelfattah M.; Bughdadi, Faisal A.; El-Shazly, Atef M.

    2013-01-01

    Currently, the laboratory diagnosis of human fascioliasis is based on the parasitological examination of parasite eggs in stool specimens and serological detection of specific antibodies in serum samples, which are often unreliable diagnostic approaches. Ideally, a sensitive and specific diagnostic test for Fasciola infection should be based on the detection of circulating Fasciola antigen, which implies active infection. Here, a 27-kDa-molecular-mass antigen was identified in a Fasciola gigantica adult worm antigen preparation, excretory-secretory products, and sera from F. gigantica-infected individuals, and it was not detected in antigenic extracts of other parasites and sera from noninfected individuals. The target antigen was isolated and partially characterized as a protein. Immunoperoxidase staining located the target epitope within teguments and guts of F. gigantica adult worms. The performance characteristics of a newly developed enzyme-linked immunosorbent assay (ELISA) based on F. gigantica circulating antigen detection in serum (FgCA-27 ELISA) were investigated using sera of 120 parasitologically diagnosed F. gigantica-infected individuals and 80 noninfected individuals. The area under the receiving operating characteristic (ROC) curve (AUC) for ELISA was significantly high (AUC = 0.961, P 93%), and a significant correlation (r = 0.715, P fascioliasis. PMID:23945158

  1. Added value of antigen ELISA in the diagnosis of neurocysticercosis in resource poor settings.

    Directory of Open Access Journals (Sweden)

    Sarah Gabriël

    Full Text Available BACKGROUND: Neurocysticercosis (NCC is the most common cause of acquired epilepsy in Taenia solium endemic areas, primarily situated in low-income countries. Diagnosis is largely based upon the "Del Brutto diagnostic criteria" using the definitive/probable/no NCC diagnosis approach. Neuroimaging and specific T. solium cysticercosis antibody detection results are at the mainstay of this diagnosis, while antigen detection in serum has never been included. This study aimed at evaluating the addition of antigen detection as a major diagnostic criterion, especially in areas where neuroimaging is absent. METHODS: The B158/B60 monoclonal antibody-based enzyme-linked immunosorbent assay (ELISA for the detection of circulating cysticercus antigen was carried out retrospectively on serum samples collected during a hospital-based study from 83 people with epilepsy (PWE in an endemic area. RESULTS: The addition of antigen results as a major criterion allowed the correct diagnosis of definitive NCC in 10 out of 17 patients as opposed to 0/17 without antigen results in the absence of neuroimaging. A sensitivity of 100% and a specificity of 84% were determined for the diagnosis of active NCC using antigen ELISA. While the use of a higher cutoff improves the specificity of the test to 96%, it decreases its sensitivity to 83%. CONCLUSIONS: In areas where neuroimaging is absent, NCC diagnosis according to the existing criteria is problematic. Taking into account its limitations for diagnosis of inactive NCC, antigen detection can be of added value for diagnosing NCC in PWE by supporting diagnostic and treatment decisions. Therefore, we recommend a revision of the "Del Brutto diagnostic criteria" for use in resource poor areas and suggest the inclusion of serum antigen detection as a major criterion.

  2. Novel indirect enzyme-linked immunosorbent assay (ELISA) method to detect Total E. coli in water environment

    International Nuclear Information System (INIS)

    Wang Na; He Miao; Shi Hanchang

    2007-01-01

    In order to establish ELISA (enzyme-linked immunosorbent assay) method to detect Total E. coli in water environment, E. coli multi-characters antigens in water environment were prepared according to the characters of kinds of E. coli serotypes, including antigen of whole cell, antigen of disrupted whole cell, somatic antigen, flagellar antigen and fimbrial antigen. Total E. coli polyclonal antibodies were obtained from the New Zealand rabbits immunized with these five antigens, respectively. Antibodies generated in this research are with high titers and good purity, can conjugate with antigens, specifically, stably and strongly. Indirect ELISA shows the titers of antibody of whole cell and antibody of disrupted whole cell are both over 1 x 10 5 . The cross-reactivity of the antibody is from 12 to 30% which indicate the specificity of the antibody against Total E. coli. Based on these antibodies, we established indirect ELISA method to detect Total E. coli in water environment. The matrix effects were studied and the results show that there is no significant influence by all the factors. The ELISA result shows that the detection limitation could be 10 4 CFU (colony forming units) L -1 . The indirect ELISA method developed in this study is well suited for Total E. coli analysis in real water samples as a rapid screen method

  3. Cell wall anchoring of the Campylobacter antigens to Lactococcus lactis

    Directory of Open Access Journals (Sweden)

    Patrycja Anna Kobierecka

    2016-02-01

    Full Text Available Campylobacter jejuni is the most frequent cause of human food-borne gastroenteritis and chicken meat is the main source of infection. Recent studies showed that broiler chicken immunization against Campylobacter should be the most efficient way to lower the number of human infections by this pathogen. Induction of the mucosal immune system after oral antigen administration should provide protective immunity to chickens. In this work we tested the usefulness of Lactococcus lactis, the most extensively studied lactic acid bacterium, as a delivery vector for Campylobacter antigens. First we constructed hybrid protein – CjaA antigen presenting CjaD peptide epitopes on its surface. We showed that specific rabbit anti-rCjaAD serum reacted strongly with both CjaA and CjaD produced by a wild type Campylobacter jejuni strain. Next, rCjaAD and CjaA were fused to the C-terminus of the L. lactis YndF containing the LPTXG motif. The genes expressing these proteins were transcribed under control of the L. lactis Usp45 promoter and their products contain the Usp45 signal sequences. This strategy ensures a cell surface location of both analysed proteins, which was confirmed by immunofluorescence assay. In order to evaluate the impact of antigen location on vaccine prototype efficacy, a L. lactis strain producing cytoplasm-located rCjaAD was also generated. Animal experiments showed a decrease of Campylobacter cecal load in vaccinated birds as compared with the control group and showed that the L. lactis harboring the surface-exposed rCjaAD antigen afforded greater protection than the L. lactis producing cytoplasm-located rCjaAD. To the best of our knowledge, this is the first attempt to employ LAB (Lactic Acid Bacteria strains as a mucosal delivery vehicle for chicken immunization. Although the observed reduction of chicken colonization by Campylobacter resulting from vaccination was rather moderate, the experiments showed that LAB strains can be considered

  4. An evaluation of purified Salmonella Typhi protein antigens for the serological diagnosis of acute typhoid fever.

    Science.gov (United States)

    Tran Vu Thieu, Nga; Trinh Van, Tan; Tran Tuan, Anh; Klemm, Elizabeth J; Nguyen Ngoc Minh, Chau; Voong Vinh, Phat; Pham Thanh, Duy; Ho Ngoc Dan, Thanh; Pham Duc, Trung; Langat, Pinky; Martin, Laura B; Galan, Jorge; Liang, Li; Felgner, Philip L; Davies, D Huw; de Jong, Hanna K; Maude, Rapeephan R; Fukushima, Masako; Wijedoru, Lalith; Ghose, Aniruddha; Samad, Rasheda; Dondorp, Arjen M; Faiz, Abul; Darton, Thomas C; Pollard, Andrew J; Thwaites, Guy E; Dougan, Gordon; Parry, Christopher M; Baker, Stephen

    2017-08-01

    The diagnosis of typhoid fever is a challenge. Aiming to develop a typhoid diagnostic we measured antibody responses against Salmonella Typhi (S. Typhi) protein antigens and the Vi polysaccharide in a cohort of Bangladeshi febrile patients. IgM against 12 purified antigens and the Vi polysaccharide was measured by ELISA in plasma from patients with confirmed typhoid fever (n = 32), other confirmed infections (n = 17), and healthy controls (n = 40). ELISAs with the most specific antigens were performed on plasma from 243 patients with undiagnosed febrile disease. IgM against the S. Typhi protein antigens correlated with each other (rho > 0.8), but not against Vi (rho Typhoid patients exhibited higher IgM against 11/12 protein antigens and Vi than healthy controls and those with other infections. Vi, PilL, and CdtB exhibited the greatest sensitivity and specificity. Specificity and sensitivity was improved when Vi was combined with a protein antigen, generating sensitivities and specificities of 0.80 and >0.85, respectively. Applying a dynamic cut-off to patients with undiagnosed febrile disease suggested that 34-58% had an IgM response indicative of typhoid. We evaluated the diagnostic potential of several S. Typhi antigens; our assays give good sensitivity and specificity, but require further assessment in differing patient populations. Copyright © 2017 The Author(s). Published by Elsevier Ltd.. All rights reserved.

  5. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-05-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  6. Characterization of ELISA Antibody-Antigen Interaction using Footprinting-Mass Spectrometry and Negative Staining Transmission Electron Microscopy

    Science.gov (United States)

    Lin, Margaret; Krawitz, Denise; Callahan, Matthew D.; Deperalta, Galahad; Wecksler, Aaron T.

    2018-03-01

    We describe epitope mapping data using multiple covalent labeling footprinting-mass spectrometry (MS) techniques coupled with negative stain transmission electron microscopy (TEM) data to analyze the antibody-antigen interactions in a sandwich enzyme-linked immunosorbant assay (ELISA). Our hydroxyl radical footprinting-MS data using fast photochemical oxidation of proteins (FPOP) indicates suppression of labeling across the antigen upon binding either of the monoclonal antibodies (mAbs) utilized in the ELISA. Combining these data with Western blot analysis enabled the identification of the putative epitopes that appeared to span regions containing N-linked glycans. An additional structural mapping technique, carboxyl group footprinting-mass spectrometry using glycine ethyl ester (GEE) labeling, was used to confirm the epitopes. Deglycosylation of the antigen resulted in loss of potency in the ELISA, supporting the FPOP and GEE labeling data by indicating N-linked glycans are necessary for antigen binding. Finally, mapping of the epitopes onto the antigen crystal structure revealed an approximate 90° relative spatial orientation, optimal for a noncompetitive binding ELISA. TEM data shows both linear and diamond antibody-antigen complexes with a similar binding orientation as predicted from the two footprinting-MS techniques. This study is the first of its kind to utilize multiple bottom-up footprinting-MS techniques and TEM visualization to characterize the monoclonal antibody-antigen binding interactions of critical reagents used in a quality control (QC) lot-release ELISA. [Figure not available: see fulltext.

  7. Identification of the antigenic region of Neospora caninum dense granule protein 7 using ELISA.

    Science.gov (United States)

    Abdelbaky, Hanan H; Fereig, Ragab M; Nishikawa, Yoshifumi

    2018-06-26

    Dense granule protein 7 (NcGRA7) is a potent diagnostic antigen of Neospora caninum. Some studies have reported on the difficult expression, low yield, and variable degree of solubility of recombinant NcGRA7. We aimed to unravel the possible causes for these issues and tested NcGRA7 antigenicity in enzyme linked immunosorbent assays (ELISAs). The NcGRA7 coding sequence (217 amino acids) was split into five amino acid regions: NcGRA7m (27-217), NcGRA7m3 (27-160), NcGRA7m4 (27-135), NcGRA7m5 (161-190), and NcGRA7m6 (188-217). Three fragments, NcGRA7m, NcGRA7m3 and NcGRA7m4, exhibited high antigenic properties when tested against experimentally-infected mice and dog sera by ELISA. High levels of IgG2 antibodies against NcGRA7m were observed in field dog sera. In experimentally and naturally-infected cattle, the N. caninum-specific sera only reacted with NcGRA7m, indicating that this antigenic region differs among the three animal species. This study presents valuable information about the antigenic properties and topology of NcGRA7, and highlights its suitability for diagnostic purposes. Copyright © 2018. Published by Elsevier B.V.

  8. Suppressor cells in transplantation tolerance. III. The role of antigen in the maintenance of transplantation tolerance

    International Nuclear Information System (INIS)

    Tutschka, P.J.; Hess, A.D.; Beschorner, W.E.; Santos, G.W.

    1982-01-01

    Suppressor cells, which in an alloantigen-specific manner inhibit proliferation of donor cells to host antigens in a mixed lymphocyte culture and adoptively transfer the suppression of graft-versus-host disease (GVHD), undergo a gradual clonal reduction in long-term, allogeneic, histoincompatible rat radiation chimeras until they can no longer be measured in an in vitro suppressor cell assay. When lymphohematopoietic cells from these chimeras are transferred into lethally irradiated secondary recipients of original donor strain, the suppressor cells, now in a target antigen-free environment, undergo a further clonal reduction. After parking for 120 days, the chimeric cells are specifically tolerant to original host antigens, but cannot adoptively transfer suppression of GVHD. When chimeric cells, parked for 120 days in secondary recipients of original donor strain, are stimulated with original host-type antigen repeatedly during or once at the end of the parking period, the suppressor cell clone is expanded, suppressor cells can be identified in vitro, and suppression of GVHD can adoptively be transferred to tertiary recipients

  9. Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells

    Directory of Open Access Journals (Sweden)

    Isabel Correa

    2018-03-01

    Full Text Available Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1 specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires.

  10. Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells.

    Science.gov (United States)

    Correa, Isabel; Ilieva, Kristina M; Crescioli, Silvia; Lombardi, Sara; Figini, Mariangela; Cheung, Anthony; Spicer, James F; Tutt, Andrew N J; Nestle, Frank O; Karagiannis, Panagiotis; Lacy, Katie E; Karagiannis, Sophia N

    2018-01-01

    Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα) as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1) specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs) were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires.

  11. Evaluation of Antigen-Conjugated Fluorescent Beads to Identify Antigen-Specific B Cells

    Science.gov (United States)

    Correa, Isabel; Ilieva, Kristina M.; Crescioli, Silvia; Lombardi, Sara; Figini, Mariangela; Cheung, Anthony; Spicer, James F.; Tutt, Andrew N. J.; Nestle, Frank O.; Karagiannis, Panagiotis; Lacy, Katie E.; Karagiannis, Sophia N.

    2018-01-01

    Selection of single antigen-specific B cells to identify their expressed antibodies is of considerable interest for evaluating human immune responses. Here, we present a method to identify single antibody-expressing cells using antigen-conjugated fluorescent beads. To establish this, we selected Folate Receptor alpha (FRα) as a model antigen and a mouse B cell line, expressing both the soluble and the membrane-bound forms of a human/mouse chimeric antibody (MOv18 IgG1) specific for FRα, as test antibody-expressing cells. Beads were conjugated to FRα using streptavidin/avidin-biotin bridges and used to select single cells expressing the membrane-bound form of anti-FRα. Bead-bound cells were single cell-sorted and processed for single cell RNA retrotranscription and PCR to isolate antibody heavy and light chain variable regions. Variable regions were then cloned and expressed as human IgG1/k antibodies. Like the original clone, engineered antibodies from single cells recognized native FRα. To evaluate whether antigen-coated beads could identify specific antibody-expressing cells in mixed immune cell populations, human peripheral blood mononuclear cells (PBMCs) were spiked with test antibody-expressing cells. Antigen-specific cells could comprise up to 75% of cells selected with antigen-conjugated beads when the frequency of the antigen-positive cells was 1:100 or higher. In PBMC pools, beads conjugated to recombinant antigens FRα and HER2 bound antigen-specific anti-FRα MOv18 and anti-HER2 Trastuzumab antibody-expressing cells, respectively. From melanoma patient-derived B cells selected with melanoma cell line-derived protein-coated fluorescent beads, we generated a monoclonal antibody that recognized melanoma antigen-coated beads. This approach may be further developed to facilitate analysis of B cells and their antibody profiles at the single cell level and to help unravel humoral immune repertoires. PMID:29628923

  12. SV40 T antigen alone drives karyotype instability that precedes neoplastic transformation of human diploid fibroblasts.

    Science.gov (United States)

    Ray, F A; Peabody, D S; Cooper, J L; Cram, L S; Kraemer, P M

    1990-01-01

    To define the role of SV40 large T antigen in the transformation and immortalization of human cells, we have constructed a plasmid lacking most of the unique coding sequences of small t antigen as well as the SV40 origin of replication. The promoter for T antigen, which lies within the origin of replication, was deleted and replaced by the Rous sarcoma virus promoter. This minimal construct was co-electroporated into normal human fibroblasts of neonatal origin along with a plasmid containing the neomycin resistance gene (neo). Three G418-resistant, T antigen-positive clones were expanded and compared to three T antigen-positive clones that received the pSV3neo plasmid (capable of expressing large and small T proteins and having two origins of replication). Autonomous replication of plasmid DNA was observed in all three clones that received pSV3neo but not in any of the three origin minus clones. Immediately after clonal expansion, several parameters of neoplastic transformation were assayed. Low percentages of cells in T antigen-positive populations were anchorage independent or capable of forming colonies in 1% fetal bovine serum. The T antigen-positive clones generally exhibited an extended lifespan in culture but rarely became immortalized. Large numbers of dead cells were continually generated in all T antigen-positive, pre-crisis populations. Ninety-nine percent of all T antigen-positive cells had numerical or structural chromosome aberrations. Control cells that received the neo gene did not have an extended life span, did not have noticeable numbers of dead cells, and did not exhibit karyotype instability. We suggest that the role of T antigen protein in the transformation process is to generate genetic hypervariability, leading to various consequences including neoplastic transformation and cell death.

  13. Monoclonal antibody-based dipstick assay: a reliable field applicable technique for diagnosis of Schistosoma mansoni infection using human serum and urine samples.

    Science.gov (United States)

    Demerdash, Zeinab; Mohamed, Salwa; Hendawy, Mohamed; Rabia, Ibrahim; Attia, Mohy; Shaker, Zeinab; Diab, Tarek M

    2013-02-01

    A field applicable diagnostic technique, the dipstick assay, was evaluated for its sensitivity and specificity in diagnosing human Schistosoma mansoni infection. A monoclonal antibody (mAb) against S. mansoni adult worm tegumental antigen (AWTA) was employed in dipstick and sandwich ELISA for detection of circulating schistosome antigen (CSA) in both serum and urine samples. Based on clinical and parasitological examinations, 60 S. mansoni-infected patients, 30 patients infected with parasites other than schistosomiasis, and 30 uninfected healthy individuals were selected. The sensitivity and specificity of dipstick assay in urine samples were 86.7% and 90.0%, respectively, compared to 90.0% sensitivity and 91.7% specificity of sandwich ELISA. In serum samples, the sensitivity and specificity were 88.3% and 91.7% for dipstick assay vs. 91.7% and 95.0% for sandwich ELISA, respectively. The diagnostic efficacy of dipstick assay in urine and serum samples was 88.3% and 90.0%, while it was 90.8% and 93.3% for sandwich ELISA, respectively. The diagnostic indices of dipstick assay and ELISA either in serum or in urine were statistically comparable (P>0.05). In conclusion, the dipstick assay offers an alternative simple, rapid, non-invasive technique in detecting CSA or complement to stool examinations especially in field studies.

  14. IL-2 absorption affects IFN-gamma and IL-5, but not IL-4 producing memory T cells in double color cytokine ELISPOT assays.

    Science.gov (United States)

    Quast, Stefan; Zhang, Wenji; Shive, Carey; Kovalovski, Damian; Ott, Patrick A; Herzog, Bernhard A; Boehm, Bernhard O; Tary-Lehmann, Magdalena; Karulin, Alexey Y; Lehmann, Paul V

    2005-09-01

    Cytokine assays are gaining increasing importance for human immune monitoring because they reliably detect antigen-specific T cells in primary PBMC, even at low clonal sizes. Double color ELISPOT assays permit the simultaneous visualization of cells producing two different cytokines. Permitting the simultaneous assessment of type 1 and 2 immunity and due to the limited numbers of PBMC available from human study subjects, double color assays should be particularly attractive for clinical trials. Since the performance of double color assays has not yet been validated, we set out to compare them to single color measurements. Testing the recall antigen-induced cytokine response of PBMC, we found that double color assays regularly provided lower numbers of IFN-gamma and IL-5 spots than single color measurements when IL-2 detection was part of the double color assay. We showed that the inhibitory effect resulted from IL-2 absorption and could be overcome by either antibody free preactivation cultures or by inclusion of anti-CD28 antibody. In contrast, the simultaneous detection of IL-2 did not affect the numbers of IL-4 spots. Therefore, unlike IL-2/IL-4 and IFN-gamma/IL-5 assays, IL-2/IFN-gamma, and IL-2/IL-5 assays require compensation for the IL-2 capture to provide accurate numbers for the frequencies of cytokine producing memory T cells.

  15. Antigenic and anticorpal diagnosis of invasive aspergillosis and candidosis in immunocompromised host

    Directory of Open Access Journals (Sweden)

    Marco Machetti

    2009-03-01

    Full Text Available Invasive aspergillosis (IA and candidemia are an increasing cause of morbidity and mortality in immunocompromised patients, but diagnostic procedures are often hampered by critical patients conditions. In recent years, non-culture methods have reached a standardization level suitable to be marketed and widely employed. A method for a panfungal antigenic diagnosis, is the detection in serum of (1→3-ß-D-Glucan (BDG, a polisaccaridic component of fungal cell wall. Best results can be obtained in Aspergillus, Candida and Fusarium infections, while the test performs poorly with Cryptococcus and in zygomycosis. The use of this method are limited by the high costs and by the need of disposable materials certified as glucan-free, in order to avoid false positive results. Galactomannan (GM antigen detection is a method for non-invasive diagnosis of IA. The assay, in latex agglutination (LA and enzymeimmunoassay (EIA format, detect GM in serum, whose presence correlates with IA. Sensitivity and specificity strongly fluctuate (50-100% and 81-98% respectively depending on the time of sampling, the positivity cut-off employed, the concomitant administration of antifungal drugs and of some antibiotics. Nevertheless the method is a very useful and widely employed tool for the diagnosis of IA. For the diagnosis of candidemia, two Candida antigens may be detected in serum: the 56°C heat-labile antigen in LA format, and the mannan antigen, in LA and EIA format. Both the methods perform quite well, but sensitivities and specificities are not so good to allow a routinely and useful use in clinical practice.

  16. Antigenic evidence of bluetongue virus from small ruminant population of two different geographical regions of Odisha, India

    Directory of Open Access Journals (Sweden)

    Shaswati Subhadarsini Pany

    2016-03-01

    Full Text Available Aim: The aim of the present study was to carry out antigenic detection of bluetongue virus (BTV among the small ruminant population of two different geographical regions of Odisha (coastal and central using recombinant VP7 (r-VP-7 based sandwich enzyme-linked immunosorbent assay (s-ELISA. Materials and Methods: Blood samples (n=274 were collected from two different geographical pockets of Odisha, which covered mostly the coastal and central regions. Of the total samples under study 185 were from goat and 89 were from sheep. The blood samples were tested for the presence of BTV antigen by r-VP7 based s-ELISA. Results: r-VP-7 s-ELISA detected BTV antigen in 52.43% and 44.94% of the goat and sheep population under study, respectively. This study highlights the antigenic persistence of BTV in the state for the 1st time. Conclusion: This high antigenic presence in both sheep and goat population suggests an alarming BTV infection in field conditions which warrants more systematic study directed toward isolation and characterization studies as well as the implementation of control strategy for BT in Odisha.

  17. Development of a bead-based Luminex assay using lipopolysaccharide specific monoclonal antibodies to detect biological threats from Brucella species.

    Science.gov (United States)

    Silbereisen, Angelika; Tamborrini, Marco; Wittwer, Matthias; Schürch, Nadia; Pluschke, Gerd

    2015-10-05

    Brucella, a Gram-negative bacterium, is classified as a potential bioterrorism agent mainly due to the low dose needed to cause infection and the ability to transmit the bacteria via aerosols. Goats/sheep, cattle, pigs, dogs, sheep and rodents are infected by B. melitensis, B. abortus, B. suis, B. canis, B. ovis and B. neotomae, respectively, the six classical Brucella species. Most human cases are caused by B. melitensis and B. abortus. Our aim was to specifically detect Brucellae with 'smooth' lipopolysaccharide (LPS) using a highly sensitive monoclonal antibody (mAb) based immunological assay. To complement molecular detection systems for potential bioterror agents, as required by international biodefense regulations, sets of mAbs were generated by B cell hybridoma technology and used to develop immunological assays. The combination of mAbs most suitable for an antigen capture assay format was identified and an immunoassay using the Luminex xMAP technology was developed. MAbs specific for the LPS O-antigen of Brucella spp. were generated by immunising mice with inactivated B. melitensis or B. abortus cells. Most mAbs recognised both B. melitensis and B. abortus and antigen binding was not impeded by inactivation of the bacterial cells by γ irradiation, formalin or heat treatment, a step required to analyse the samples immunologically under biosafety level two conditions. The Luminex assay recognised all tested Brucella species with 'smooth' LPS with detection limits of 2×10(2) to 8×10(4) cells per mL, depending on the species tested. Milk samples spiked with Brucella spp. cells were identified successfully using the Luminex assay. In addition, the bead-based immunoassay was integrated into a multiplex format, allowing for simultaneous, rapid and specific detection of Brucella spp., Bacillus anthracis, Francisella tularensis and Yersinia pestis within a single sample. Overall, the robust Luminex assay should allow detection of Brucella spp. in both natural

  18. Development of a PMMA Electrochemical Microfluidic Device for Carcinoembryonic Antigen Detection

    Science.gov (United States)

    Van Anh, Nguyen; Van Trung, Hoang; Tien, Bui Quang; Binh, Nguyen Hai; Ha, Cao Hong; Le Huy, Nguyen; Loc, Nguyen Thai; Thu, Vu Thi; Lam, Tran Dai

    2016-05-01

    In this study, a poly(methyl methacrylate) (PMMA) microfluidic device fabricated by an inexpensive CO2 laser etching system was developed for detection of carcino-embryonic antigens (CEA). The device was capable of working in continuous mode and was designed with the aid of numerical simulation. The detection of target CEA was based on immuno-assay via magnetic particles and electrochemical sensing. The as-prepared microfluidic can be used to detect CEA at the relatively low concentration of 150 pg mL-1. The device could be reused many times, since the capture and removal of magnetic particles in the assay could be manipulated by an external magnetic field. The proposed approach appears to be suitable for high-throughput and automated analysis of large biomolecules such as tumor markers and pathogens.

  19. Prenatal typing of Rh and Kell blood group system antigens: the edge of a watershed.

    Science.gov (United States)

    van der Schoot, C Ellen; Tax, G H Martine; Rijnders, Robbert J P; de Haas, Masja; Christiaens, Godelieve C M L

    2003-01-01

    management of the pregnancies of alloimmunized women, the development of a control for the presence and the amplification of fetal DNA is needed, which is at present only available in male pregnancies. Assays for the genotyping of the other Rh antigens or Kell antigens with cell-free fetal DNA have not yet been described. Copyright 2003, Elsevier Science (USA). All rights reserved.

  20. Antigen processing and remodeling of the endosomal pathway: requirements for antigen cross-presentation.

    Science.gov (United States)

    Compeer, Ewoud Bernardus; Flinsenberg, Thijs Willem Hendrik; van der Grein, Susanna Geertje; Boes, Marianne

    2012-01-01

    Cross-presentation of endocytosed antigen as peptide/class I major histocompatibility complex complexes plays a central role in the elicitation of CD8(+) T cell clones that mediate anti-viral and anti-tumor immune responses. While it has been clear that there are specific subsets of professional antigen presenting cells capable of antigen cross-presentation, identification of mechanisms involved is still ongoing. Especially amongst dendritic cells (DC), there are specialized subsets that are highly proficient at antigen cross-presentation. We here present a focused survey on the cell biological processes in the endosomal pathway that support antigen cross-presentation. This review highlights DC-intrinsic mechanisms that facilitate the cross-presentation of endocytosed antigen, including receptor-mediated uptake, maturation-induced endosomal sorting of membrane proteins, dynamic remodeling of endosomal structures and cell surface-directed endosomal trafficking. We will conclude with the description of pathogen-induced deviation of endosomal processing, and discuss how immune evasion strategies pertaining endosomal trafficking may preclude antigen cross-presentation.

  1. Antigen processing and remodeling of the endosomal pathway: requirements for antigen cross-presentation.

    Directory of Open Access Journals (Sweden)

    Ewoud Bernardus Compeer

    2012-03-01

    Full Text Available The cross-presentation of endocytosed antigen as peptide/class I MHC complexes plays a central role in the elicitation of CD8+ T cell clones that mediate anti-viral and anti-tumor immune responses. While it has been clear that there are specific subsets of professional antigen presenting cells (APC capable of antigen cross-presentation, description of mechanisms involved is still ongoing. Especially amongst dendritic cells (DC, there are specialized subsets that are highly proficient at antigen cross-presentation. We here present a focused survey on the cell biological processes in the endosomal pathway that support antigen cross-presentation. This review highlight DC-intrinsic mechanisms that facilitate the cross-presentation of endocytosed antigen, including receptor-mediated uptake, recycling and maturation including the sorting of membrane proteins, dynamic remodeling of endosomal structures and cell-surface directed endosomal trafficking. We will conclude with description of pathogen-induced deviation of endosomal processing, and discuss how immune evasion strategies pertaining endosomal trafficking may preclude antigen cross-presentation.

  2. Improving dengue viral antigens detection in dengue patient serum specimens using a low pH glycine buffer treatment.

    Science.gov (United States)

    Shen, Wen-Fan; Galula, Jedhan Ucat; Chang, Gwong-Jen J; Wu, Han-Chung; King, Chwan-Chuen; Chao, Day-Yu

    2017-04-01

    Early diagnosis of dengue virus (DENV) infection to monitor the potential progression to hemorrhagic fever can influence the timely management of dengue-associated severe illness. Nonstructural protein 1 (NS1) antigen detection in acute serum specimens has been widely accepted as an early diagnostic assay for dengue infection; however, lower sensitivity of the NS1 antigen-capture enzyme-linked immunosorbent assay (Ag-ELISA) in secondary dengue viral infection has been reported. In this study, we developed two forms of Ag-ELISA capable of detecting E-Ag containing virion and virus-like particles, and secreted NS1 (sNS1) antigens, respectively. The temporal kinetics of viral RNA, sNS1, and E-Ag were evaluated based on the in vitro infection experiment. Meanwhile, a panel of 62 DENV-2 infected patients' sera was tested. The sensitivity was 3.042 ng/mL and 3.840 ng/mL for sNS1 and E, respectively. The temporal kinetics of the appearance of viral RNA, E, NS1, and infectious virus in virus-infected tissue culture media suggested that viral RNAs and NS1 antigens could be detected earlier than E-Ag and infectious virus. Furthermore, a panel of 62 sera from patients infected by DENV Serotype 2 was tested. Treating clinical specimens with the dissociation buffer increased the detectable level of E from 13% to 92% and NS1 antigens from 40% to 85%. Inclusion of a low-pH glycine buffer treatment step in the commercially available Ag-ELISA is crucial for clinical diagnosis and E-containing viral particles could be a valuable target for acute DENV diagnosis, similar to NS1 detection. Copyright © 2015. Published by Elsevier B.V.

  3. Proteomics-Based Characterization of the Humoral Immune Response in Sporotrichosis: Toward Discovery of Potential Diagnostic and Vaccine Antigens.

    Directory of Open Access Journals (Sweden)

    Anderson Messias Rodrigues

    Full Text Available Sporothrix schenckii and associated species are agents of human and animal sporotrichosis that cause large sapronoses and zoonoses worldwide. Epidemiological surveillance has highlighted an overwhelming occurrence of the highly pathogenic fungus Sporothrix brasiliensis during feline outbreaks, leading to massive transmissions to humans. Early diagnosis of feline sporotrichosis by demonstrating the presence of a surrogate marker of infection can have a key role for selecting appropriate disease control measures and minimizing zoonotic transmission to humans.We explored the presence and diversity of serum antibodies (IgG specific against Sporothrix antigens in cats with sporotrichosis and evaluated the utility of these antibodies for serodiagnosis. Antigen profiling included protein extracts from the closest known relatives S. brasiliensis and S. schenckii. Enzyme-linked immunosorbent assays and immunoblotting enabled us to characterize the major antigens of feline sporotrichosis from sera from cats with sporotrichosis (n = 49, healthy cats (n = 19, and cats with other diseases (n = 20.Enzyme-linked immunosorbent assay-based quantitation of anti-Sporothrix IgG exhibited high sensitivity and specificity in cats with sporotrichosis (area under the curve, 1.0; 95% confidence interval, 0.94-1; P<0.0001 versus controls. The two sets of Sporothrix antigens were remarkably cross-reactive, supporting the hypothesis that antigenic epitopes may be conserved among closely related agents. One-dimensional immunoblotting indicated that 3-carboxymuconate cyclase (a 60-kDa protein in S. brasiliensis and a 70-kDa protein in S. schenckii is the immunodominant antigen in feline sporotrichosis. Two-dimensional immunoblotting revealed six IgG-reactive isoforms of gp60 in the S. brasiliensis proteome, similar to the humoral response found in human sporotrichosis.A convergent IgG-response in various hosts (mice, cats, and humans has important implications for our

  4. Diagnostic value of tissue polypeptide specific antigen in serum for patients with pancreatic carcinoma

    International Nuclear Information System (INIS)

    Lu Yun; Liu Xingdang; Li Ding; Dei Shouzhen

    2009-01-01

    Objective: To compare the diagnostic value of tissue polypeptide specific antigen (TPS) in serum, with the carbohydrate antigens (CA) 19-9, CA50, CA125 and CA242 in pancreatic carcinoma. Methods: Serum TPS was measured with enzyme linked immunosorbent assay (ELISA). CA19-9 and CA125 were measured with chemiluminescent immunoassay. CAS0 and CA242 were measured with immunoradiometric assay in 33 patients with pancreatitis, 34 patients with pathologically proven pancreatic carcinoma, and 35 patients with non-pancreatic malignancies. Statistic analysis was carried out with SPSS 9.0 software. Results: Patients with pancreatic carcinoma had relatively higher levels of TPS [(386.5 ± 315. 1) U/L] and CA19-9 [(10 820.9 ± 389.7) kU/L] when compared with patients with pancreatitis [(86. 2 ± 28.1) U/L and (61.5 ± 24.7) kU/L, respectively; F = 936. 42, P < 0. 001 ; F = 2217. 09, P < 0. 001], with a sensitivity and a specificity of 70.6% (48/68) and 57.4% (39/68), respectively, for TPS, and 82.4% (28/34) and 77.9% (53/68), respectively, for CA19-9. Diagnostic performance was further improved when TPS was assayed in combination with CA19-9, CA50, CA125 and CA242. Conclusion: Serum TPS has an incremental value in complementing CA19-9 in the diagnosis of pancreatic carcinoma. (authors)

  5. Diabetes is associated with lower tuberculosis antigen-specific interferon gamma release in Tanzanian tuberculosis patients and non-tuberculosis controls

    DEFF Research Database (Denmark)

    Faurholt-Jepsen, Daniel; Aabye, Martine Grosos; Jensen, Andreas Vestergaard

    2014-01-01

    in diabetes patients and therefore the validity of interferon gamma release assays (IGRA) may be compromised. The aim of the present study was to assess the association between diabetes and Mycobacterium tuberculosis (Mtb) antigen-specific interferon gamma (IFN-γ) release in a TB endemic area among culture......-confirmed TB patients and non-TB controls. Methods: Culture-confirmed pulmonary TB patients (n = 187) and healthy non-TB neighbourhood controls (n = 190) from Mwanza, Tanzania were tested for the presence of circulating T cells recognizing Mtb antigens using an IGRA. The diabetes status of all participants...

  6. Rapid assay of intrinsic radiosensitivity based on apoptosis in human CD4 and CD8 T-lymphocytes

    International Nuclear Information System (INIS)

    Ozsahin, Mahmut; Ozsahin, Huelya; Yuquan, Shi; Larsson, Boerje; Wuergler, Friedrich E.; Crompton, Nigel E. A.

    1997-01-01

    Purpose: An assay for radiosensitivity has numerous applications in the clinic. Avoidance of acute responses, prediction of normal tissue toxicity, and individualization of patient radiotherapy are included among these. We have developed a rapid assay (about 24 h) able to predict intrinsic radiosensitivity of CD4 and CD8 T-lymphocytes based on radiation-induced apoptosis. Methods and Materials: Fresh blood samples (1-2 ml in heparinized tubes) were irradiated with 0-, 2-, and 8-Gy X rays at a dose rate of approximately 3 Gy/min. Following irradiation, the cells were collected and prepared for flow-cytometric analysis and cell sorting. In conjunction with the CellQuest software available with the FACSVantage cell sorter (Becton-Dickinson), two T-lymphocyte types were analyzed on the basis of their cell-specific antigens (CD4 and CD8), and DNA was stained with DAPI. Following the separation of these cell types, radiation-induced cell death was assessed. Cytotoxicity was characterized by gradual degradation of internucleosomal DNA which results in a sub-G1 peak on the DNA histogram, and by the associated loss of surface antigens causing an intermediate positive peak in the antibody histogram. Using the assay, we investigated the interdonor variation in a cohort of 45 healthy adult blood donors and 5 children [one had immunodeficiency, centromeric instability, and facial anomalies syndrome (ICF), and one had ataxia telangiectasia (AT)]. Intradonor variation was assessed with 10 different experiments from a single donor. Results: CD4 and CD8 T-lymphocyte radiosensitivities were correlated (r 0.63 and 0.65 for 2 and 8 Gy, respectively) in 45 adult donors. Both for CD4 and CD8 cells, 2 and 8 Gy irradiation responses showed a good correlation (r 0.77 for both). Interdonor variation was significantly higher than intradonor variation (p < 0.0005) for all CD4 and CD8 data. We observed a decrease in the antigen fluorescence of dying cells, a phenomenon referred to as antigen

  7. Factors influencing in vitro respiratory burst assays with head kidney leucocytes from rainbow trout, Oncorhynchus mykiss (Walbaum)

    DEFF Research Database (Denmark)

    Chettri, Jiwan Kumar; Holten-Andersen, Lars; Buchmann, Kurt

    Head kidney leukocytes are central elements in a number of in vivo and in vitro assays elucidating innate and adaptive immune mechanisms in teleosts following stimulation with various antigens. These systems are sensitive to a number of factors affecting the outcome of the assays. The present work...... from cells in a concentration of 1 x 104 cells/ml. Co-incubation of cells with inhibitory substances (DiMePE2, cortisol and SOD) decreased the RBA. It is concluded that several biotic and abiotic factors should be taken into account when conducting RBA assays with head kidney leukocytes for elucidation...

  8. Comparison of five assays for detection of Clostridium difficile toxin.

    Science.gov (United States)

    Chapin, Kimberle C; Dickenson, Roberta A; Wu, Fongman; Andrea, Sarah B

    2011-07-01

    Performance characteristics of five assays for detection of Clostridium difficile toxin were compared using fresh stool samples from patients with C. difficile infection (CDI). Assays were performed simultaneously and according to the manufacturers' instructions. Patients were included in the study if they exhibited clinical symptoms consistent with CDI. Nonmolecular assays included glutamate dehydrogenase antigen tests, with positive findings followed by the Premier Toxin A and B Enzyme Immunoassay (GDH/EIA), and the C. Diff Quik Chek Complete test. Molecular assays (PCR) included the BD GeneOhm Cdiff Assay, the Xpert C. difficile test, and the ProGastro Cd assay. Specimens were considered true positive if results were positive in two or more assays. For each method, the Youden index was calculated and cost-effectiveness was analyzed. Of 81 patients evaluated, 26 (32.1%) were positive for CDI. Sensitivity of the BD GeneOhm Cdiff assay, the Xpert C. difficile test, the ProGastro Cd assay, C. Diff Quik Chek Complete test, and two-step GDH/EIA was 96.2%, 96.2%, 88.5%, 61.5%, and 42.3%, respectively. Specificity of the Xpert C. difficile test was 96.4%, and for the other four assays was 100%. Compared with nonmolecular methods, molecular methods detected 34.7% more positive specimens. Assessment of performance characteristics and cost-effectiveness demonstrated that the BD GeneOhm Cdiff assay yielded the best results. While costly, the Xpert C. difficile test required limited processing and yielded rapid results. Because of discordant results, specimen processing, and extraction equipment requirements, the ProGastro Cd assay was the least favored molecular assay. The GDH/EIA method lacked sufficient sensitivity to be recommended. Copyright © 2011 American Society for Investigative Pathology and the Association for Molecular Pathology. Published by Elsevier Inc. All rights reserved.

  9. In vitro stimulation of rabbit T lymphocytes by cells expressing herpes simplex antigens.

    Science.gov (United States)

    Kapoor, A K; Ling, N R; Nash, A A; Bachan, A; Wildy, P

    1982-04-01

    Lymphocyte stimulation responses to herpes antigens were studied using virus-infected X-irradiated cells. Rabbits were immunized with herpes simplex virus type 1 (strain HFEM) grown in RK 13 cells. For in vitro stimulation assay BHK21 cells were X-irradiated (15 000 rad) and infected with a high m.o.i. of a temperature-sensitive (ts) mutant (N102) of HFEM strain at the non-permissive temperature (38.5 degrees C) of virus. Virus antigens were expressed on the infected cells and there was no leakage of infectious virus into the medium at 38.5 degrees C. T lymphocytes from rabbits immunized with herpes simplex virus were specifically activated by herpesvirus-infected X-irradiated cells; lymph node cells from rabbits immunized with RK13 cells and from non-immune rabbits showed no proliferative response.

  10. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection

    Science.gov (United States)

    Cross, Robert W.; Boisen, Matthew L.; Millett, Molly M.; Nelson, Diana S.; Oottamasathien, Darin; Hartnett, Jessica N.; Jones, Abigal B.; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A.; Fusco, Marnie L.; Abelson, Dafna M.; Oda, Shunichiro; Brown, Bethany L.; Pham, Ha; Rowland, Megan M.; Agans, Krystle N.; Geisbert, Joan B.; Heinrich, Megan L.; Kulakosky, Peter C.; Shaffer, Jeffrey G.; Schieffelin, John S.; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M.; Wilson, Russell B.; Saphire, Erica Ollmann; Pitts, Kelly R.; Khan, Sheik Humarr; Grant, Donald S.; Geisbert, Thomas W.; Branco, Luis M.; Garry, Robert F.

    2016-01-01

    Background. Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013–2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases. Methods. Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance. Results. The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription–polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 105–9.0 × 108 genomes/mL. Conclusions. The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. PMID:27587634

  11. Immunoglobulin G1 enzyme-linked Immunosorbent assay for diagnosis of Johne's disease in red deer (Cervus elaphus)

    NARCIS (Netherlands)

    Griffin, J.F.T.; Spittle, E.; Rodgers, C.R.; Liggett, S.; Cooper, M.; Bakker, D.; Bannantine, J.P.

    2005-01-01

    This study was designed to develop a customized enzyme-linked immunosorbent assay (ELISA) for the serodiagnosis of Johne's disease (JD) in farmed deer. Two antigens were selected on the basis of their superior diagnostic readouts: denatured purified protein derivative (PPDj) and undenatured

  12. Studies of cytotoxic antibodies against eye muscle antigens in patients with thyroid-associated ophthalmopathy

    International Nuclear Information System (INIS)

    Zhang, Z.-G.; Hiromatsu, Y.; Salvi, M.; Triller, H.; Bernard, N.; Wall, J.R.; Medeiros-Neto, G.; Iacona, A.; Lima, N.

    1989-01-01

    We have studied the prevalence and significance of cytotoxic antibodies against human eye muscle cells, as detected in antibody-dependent cell-mediated cytotoxicity (ADCC) and complement-mediated antibody-dependent cytotoxicity (CMAC) in 51 Cr release assays, in patients with Graves' ophthalmopathy or Hashimoto's thyroiditis. A high prevalence of positive ADCC tests was found in all groups of patients with ophthalmopathy tested. Tests were positive in 64% of patients with Graves' ophthalmopathy from an area of severe iodine deficiency (Sao Paulo) and in 64% of such patients from an iodine replete area (Montreal). In patients with so-called ''euthyroid ophthalmopathy'', i.e. eye disease associated with thyroiditis, ADCC tests were positive in 75 and 38% of patients from the two areas, respectively, while tests were positive in 40 and 22%, respectively, of patients with Graves' hyperthyroidism without evident eye disease. In normal subjects, levels of 51 Cr release was always at background levels. In a group of patients from the high-iodine area, levels of antibodies in ADCC correlated positively with the intraocular pressure (mmHg) in primary position as a parameter of eye muscle dysfunction. In patients with ophthalmopathy, positive ADCC tests were assciated with antibodies to eye muscle membrane antigens of 55,65 and 95 kD as detected by immunoblotting, although the correlation was not close for any antigen. in contrast, CMAC tests were negative in all patients with ophthalmopathy. We also tested 9 mouse and 10 human monoclonal antibodies, reactive with orbital antigens in an enzyme-linked immunosorbent assay, for cytotoxic activity, in ADCC and CMAC, against eye muscle and thyroid cells. All monoclonal antibodies were of the IgM class and negative in ADCC assays. When tested in CMAC against eye muscle cells, one of 9 mouse and 5 of 8 human monoclonal antibodies showed significant activity while tests were positive in one of 9 and one of 10 monoclonal antibodies

  13. Validity and reliability of enzyme immunoassays using Leishmania major or L. infantum antigens for the diagnosis of canine visceral leishmaniasis in Brazil.

    Directory of Open Access Journals (Sweden)

    Mauro Maciel de Arruda

    Full Text Available BACKGROUND: American visceral leishmaniasis is caused by the protozoan Leishmania infantum. Dogs are the main reservoirs in the domestic transmission cycle. The limited accuracy of diagnostic tests for canine leishmaniasis may contribute to the lack of impact of control measures recommended by the Brazilian Ministry of Health. The objective of this study was to estimate the accuracy of two enzyme-linked immunosorbent assays employing L. major or L. infantum antigens and their reliability between three laboratories of different levels of complexity. METHODS: A validation study of ELISA techniques using L. major or L. infantum antigens was conducted. Direct visualization of the parasite in hematoxylin/eosin-stained histopathological sections, immunohistochemistry, and isolation of the parasite in culture.were used as gold standard. An animal that was positive in at least one of the tests was defined as infected with L. infantum. Serum samples collected from 1,425 dogs were analyzed. Samples were separated in three aliquots and tested in three different laboratories. Sensitivity, specificity and the area under de ROC curve were calculated and the reliability was evaluated between the participant laboratories. RESULTS: The sensitivity was 91.8% and 89.8% for the L. major and L. infantum assays, respectively. The specificity was 83.75% and 82.7% for the L. major and L. infantum assays, respectively. The area under de ROC curve was 0.920 and 0.898 for L. major and L. infantum, respectively. The mean intraclass correlation coefficients between laboratories ranged from 0.890 to 0.948 when L. major was used as antigen, and from 0.818 to 0.879 when L. infantum was used. INTERPRETATION: ELISA tests using L. major or L. infantum antigens have similar accuracy and reliability. Our results do not support the substitution of the L. major antigen of the ELISA test currently used for the diagnosis of canine visceral leishmaniasis in Brazil.

  14. Serodiagnosis of cutaneous leishmaniasis: assessment of an enzyme-linked immunosorbent assay using a peptide sequence from gene B protein

    DEFF Research Database (Denmark)

    Jensen, A T; Gaafar, A; Ismail, A

    1996-01-01

    An enzyme-linked immunosorbent assay (ELISA) using a 28 amino acid sequence of the repetitive element of gene B protein (GBP) from Leishmania major was developed for serodiagnosis of cutaneous leishmaniasis (CL). The assay was compared to ELISAs using crude amastigote and promastigote antigens from...... samples from healthy Sudanese individuals living in an area endemic for malaria but free of leish-maniasis were negative in all the assays. Significantly higher levels of antibodies were found in the patients who had suffered from the disease for more than eight weeks than in patients with a shorter...

  15. In vitro immunomodulation of a whole blood IFN-γ release assay enhances T cell responses in subjects with latent tuberculosis infection.

    Directory of Open Access Journals (Sweden)

    Rajiv L Gaur

    Full Text Available Activation of innate immunity via pathogen recognition receptors (PRR modulates adaptive immune responses. PRR ligands are being exploited as vaccine adjuvants and as therapeutics, but their utility in diagnostics has not been explored. Interferon-gamma (IFN-γ release assays (IGRAs are functional T cell assays used to diagnose latent tuberculosis infection (LTBI; however, novel approaches are needed to improve their sensitivity.In vitro immunomodulation of a whole blood IGRA (QuantiFERON®-TB GOLD In-Tube with Toll-like receptor agonists poly(I:C, LPS, and imiquimod was performed on blood from subjects with LTBI and negative controls.In vitro immunomodulation significantly enhanced the response of T cells stimulated with M. tuberculosis antigens from subjects with LTBI but not from uninfected controls. Immunomodulation of IGRA revealed T cell responses in subjects with LTBI whose T cells otherwise do not respond to in vitro stimulation with antigens alone. Similar to their in vivo functions, addition of poly(I:C and LPS to whole blood induced secretion of inflammatory cytokines and IFN-α and enhanced the surface expression of antigen presenting and costimulatory molecules on antigen presenting cells.In vitro immunomodulation of whole blood IGRA may be an effective strategy for enhancing the sensitivity of T cells for diagnosis of LTBI.

  16. Development of an indirect ELISA to detect Corynebacterium pseudotuberculosis specific antibodies in sheep employing T1 strain culture supernatant as antigen

    Directory of Open Access Journals (Sweden)

    Miriam F. Rebouças

    2013-11-01

    Full Text Available Corynebacterium pseudotuberculosis is the etiologic agent of caseous lymphadenitis (CLA, a chronic disease that affects goats and sheep, characterized by granuloma formation in subcutaneous and internal lymph nodes. CLA causes significant economic losses to commercial goat herds. In this study, we aimed to test secreted antigens secreted from T1 strain bacteria grown in brain heart infusion (BHI broth in an indirect ELISA system to determine the presence of specific immunoglobulins against C. pseudotuberculosis. We analyzed the BHI antigen electrophoretic profile and the recognition pattern by infected sheep sera samples. The ELISA results were compared with multiplex PCR assay and IFN-gamma production. The ELISA was able to discriminate between negative and positive animals, with a sensitivity of 89% and a specificity of 99%, using microbiological isolation as gold standard. When this assay was compared with multiplex PCR and specific IFN-gamma quantification, six discrepant results were found among thirty-two samples. We concluded that the ELISA using antigens secreted from C. pseudotuberculosis T1 strain growth in BHI broth culture can be used for the serodiagnosis of CLA in sheep.

  17. Microculture virus titration--a simple colourimetric assay for influenza virus titration.

    Science.gov (United States)

    Levi, R; Beeor-Tzahar, T; Arnon, R

    1995-03-01

    Influenza antigens can be detected by several well established methods. However, when it is important to determine the titre of infective virions, a bioassay should be employed. The standard and the most widely used tests for influenza infectivity are titration carried out in embryonated hen eggs, or the plaque assay employing tissue culture techniques. A simple colourimetric assay for influenza virus detection and titration is described. Samples of allantoic fluid or mice lung homogenates were used to infect MDCK cultures in microplate wells. After an incubation period, the tetrazolium (MTT) colourimetric assay was used to determine cell viability, and when compared to untreated culture control enabled the detection and titration of several influenza strains. When samples were assayed simultaneously in embryonated eggs and by the MCVT method, good correlation in determined titres was obtained. The availability of an additional method for influenza titration allows more flexibility in the choice of titration method according to the specific needs of the study. Furthermore, this method lends itself to full automatization. Similar procedures should also be applicable to titration of other cytopathic viruses.

  18. First field trial of an immunoradiometric assay for the detection of malaria sporozoites in mosquitoes

    International Nuclear Information System (INIS)

    Collins, F.H.; Zavala, F.; Graves, P.M.; Cochrane, A.H.; Gwadz, R.W.; Akoh, J.; Nussenzweig, R.S.

    1984-01-01

    An immunoradiometric assay (IRMA) using a monoclonal antibody to the major surface protein of Plasmodium falciparum sporozoites was used to assess the P. falciparum sporozoite rate in a West African population of Anopheles gambiae (s.1.). Unlike current dissection techniques, the IRMA could detect sporozoite antigen in dried as well as fresh mosquitoes. In a controlled comparison, the sensitivity of the IRMA was comparable that of the dissection technique. Additionally, the IRMA was species specific and quantitative. Sensitivity of the assay was sufficient to detect sporozoite infections resulting from the development of a single oocyst

  19. Studies on antigenic cross-reactivity of Trichuris ovis with host mucosal antigens in goat

    Directory of Open Access Journals (Sweden)

    Gautam Patra

    2015-12-01

    Full Text Available Objective: To ascertain whether immunodominant antigens of Trichuris ovis might share and cross react with host molecule. Methods: Two crude protein preparations from anterior and posterior parts of Trichuris ovis were characterized along with host mucosal antigen by double immunodiffusion, sodium dodecyl sulfate-polyacrylamide gel electrophoresis and western blotting technique. Conventional scanning electron microscopy was performed as per standard procedure. Results: Sharp and distinct bands of three antigens have been found in double immunodiffusion using hyperimmune serum raised in rabbit indicating the presence of specific antibody against each antigen. All three antigens have shown major and minor bands with molecular weight ranging from 15 to 110 kDa during sodium dodecyl sulfate-polyacrylamide gel electrophoresis. Conclusions: The antigenic cross-reactivity was thought to result from shared antigens. The existence of paracloacal papillae found in the anterior part of the male was not a unique feature for species differentiation.

  20. Cellular and humoral immune responses in sheep vaccinated with candidate antigens MAP2698c and MAP3567 from Mycobacterium avium subspecies paratuberculosis

    Science.gov (United States)

    Gurung, Ratna B.; Purdie, Auriol C.; Whittington, Richard J.; Begg, Douglas J.

    2014-01-01

    Control of Johne's disease, caused by Mycobacterium avium subspecies paratuberculosis (MAP) in ruminants using commercially available vaccine reduces production losses, mortality, fecal shedding and histopathological lesions but does not provide complete protection from infection and interferes with serological diagnosis of Johne's disease and bovine tuberculosis. At this time no recombinant antigens have been found to provide superior protection compared to whole killed or live-attenuated MAP vaccines. Therefore, there is a need to evaluate more candidate MAP antigens. In this study recombinant MAP antigens MAP2698c and MAP3567 were formulated with four different MONTANIDE™ (ISA 50V2, 61VG, 71VG, and 201VG) adjuvants and evaluated for their ability to produce specific immune responses in vaccinated sheep. The cellular immune response was measured with an interferon-gamma (IFN-γ) release assay and the humoral immune response was measured by antibody detection enzyme linked immunosorbent assay. Recombinant vaccine formulation with the antigen MAP2698c and MONTANIDE™ ISA 201VG adjuvant produced strong whole-MAP as well as MAP2698c-specific IFN-γ responses in a high proportion of the vaccinated sheep. The formulation caused less severe injection site lesions in comparison to other formulations. The findings from this study suggest that the MAP2698c + 201VG should be evaluated in a challenge trial to determine the efficacy of this vaccine candidate. PMID:25077074

  1. Design of indirect solid-phase immunosorbent methods for detecting arenavirus antigens and antibodies

    Energy Technology Data Exchange (ETDEWEB)

    Ivanov, A P; Rezapkin, G V; Dzagurova, T K; Tkachenko, E A

    1984-05-01

    Specifications have been elaborated for formulating indirect solid-phase enzyme-linked immunosorbent assay (ELISA) and radioimmunoassay (SPRIA) methods that employ anti-human and anti-mice G class immunoglobulin (IgG), conjugated with horseradish peroxidase and /sup 125/I for detecting the arenaviruses Junin, Machupo, Tacaribe, Amalpari, Tamiami, Lassa, and LCM (lymphocytic choriomeningitis). These methods make it possible to identify with a high degree of sensitivity arenavirus antigens and antibodies in various kinds of material.

  2. Experimental Design and Methods for Development of Diagnostic Assays for Schistosomiasis Using Monoclonal Antibodies.

    Science.gov (United States)

    1983-08-25

    solium, Echinococcus granulosus , Entamoeba histolytica, or Wucher erTra-bancr--ofti. The S. mansoni glycoproteins that were immunoprecipitated by sera...Sera from patients or experimental animals infected with Schistosoma, Fasciola hepatica, Trichinella spiralis, Taenia solium, Echinococcus ... granulosus , or Paragonimus westermani cross-react in diag-nostic assays with antigens derived from schistosomes, whether as whole organisms (1-4), crude

  3. Polymer nanoparticles for cross-presentation of exogenous antigens and enhanced cytotoxic T-lymphocyte immune response

    Directory of Open Access Journals (Sweden)

    Song C

    2016-08-01

    Full Text Available Chanyoung Song,* Young-Woock Noh,* Yong Taik Lim SKKU Advanced Institute of Nanotechnology (SAINT, School of Chemical Engineering, Sungkyunkwan University, Suwon, South Korea *These authors contributed equally to this work Abstract: Effective induction of an antigen-specific cytotoxic T lymphocyte (CTL immune response is one of the key goals of cancer immunotherapy. We report the design and fabrication of polyethylenimine (PEI-coated polymer nanoparticles (NPs as efficient antigen-delivery carriers that can induce antigen cross-presentation and a strong CTL response. After synthesis of poly(d,l-lactide-co-glycolide (PLGA NPs containing ovalbumin (OVA by the double-emulsion solvent-evaporation method, cationic-charged PLGA NPs were generated by coating them with PEI. In a methyl tetrazolium salt assay, no discernible cytotoxic effect of PEI-coated PLGA (OVA NPs was observed. The capacity and mechanism of PEI-coated PLGA (OVA NPs for antigen delivery and cross-presentation on dendritic cells (DCs were determined by fluorescence microscopy and flow cytometry. PEI-coated PLGA (OVA NPs were internalized efficiently via phagocytosis or macropinocytosis in DCs and induced efficient cross-presentation of the antigen on MHC class I molecules via both endosome escape and a lysosomal processing mechanism. The DCs treated with PEI-coated PLGA (OVA NPs induced a release of IL-2 cytokine from OVA-specific CD8-OVA1.3 T cells more efficiently than DCs treated with PLGA (OVA NPs. Therefore, the PEI-coated PLGA (OVA NPs can induce antigen cross-presentation and are expected to be used for induction of a strong CTL immune response and for efficient anticancer immunotherapy. Keywords: antigen delivery, dendritic cells, polymer NPs, vaccine, cross-presentation

  4. Antigenic modulation limits the effector cell mechanisms employed by type I anti-CD20 monoclonal antibodies.

    Science.gov (United States)

    Tipton, Thomas R W; Roghanian, Ali; Oldham, Robert J; Carter, Matthew J; Cox, Kerry L; Mockridge, C Ian; French, Ruth R; Dahal, Lekh N; Duriez, Patrick J; Hargreaves, Philip G; Cragg, Mark S; Beers, Stephen A

    2015-03-19

    Following the success of rituximab, 2 other anti-CD20 monoclonal antibodies (mAbs), ofatumumab and obinutuzumab, have entered clinical use. Ofatumumab has enhanced capacity for complement-dependent cytotoxicity, whereas obinutuzumab, a type II mAb, lacks the ability to redistribute into lipid rafts and is glycoengineered for augmented antibody-dependent cellular cytotoxicity (ADCC). We previously showed that type I mAbs such as rituximab have a propensity to undergo enhanced antigenic modulation compared with type II. Here we assessed the key effector mechanisms affected, comparing type I and II antibodies of various isotypes in ADCC and antibody-dependent cellular-phagocytosis (ADCP) assays. Rituximab and ofatumumab depleted both normal and leukemic human CD20-expressing B cells in the mouse less effectively than glycoengineered and wild-type forms of obinutuzumab, particularly when human immunoglobulin G1 (hIgG1) mAbs were compared. In contrast to mouse IgG2a, hIgG1 mAbs were ineffective in ADCC assays with murine natural killer cells as effectors, whereas ADCP was equivalent for mouse IgG2a and hIgG1. However, rituximab's ability to elicit both ADCC and ADCP was reduced by antigenic modulation, whereas type II antibodies remained unaffected. These data demonstrate that ADCP and ADCC are impaired by antigenic modulation and that ADCP is the main effector function employed in vivo. © 2015 by The American Society of Hematology.

  5. Strong interferon-gamma mediated cellular immunity to scrub typhus demonstrated using a novel whole cell antigen ELISpot assay in rhesus macaques and humans.

    Directory of Open Access Journals (Sweden)

    Manutsanun Sumonwiriya

    2017-09-01

    Full Text Available Scrub typhus is a febrile infection caused by the obligate intracellular bacterium Orientia tsutsugamushi, which causes significant morbidity and mortality across the Asia-Pacific region. The control of this vector-borne disease is challenging due to humans being dead-end hosts, vertical maintenance of the pathogen in the vector itself, and a potentially large rodent reservoir of unclear significance, coupled with a lack of accurate diagnostic tests. Development of an effective vaccine is highly desirable. This however requires better characterization of the natural immune response of this neglected but important disease. Here we implement a novel IFN-γ ELISpot assay as a tool for studying O. tsutsugamushi induced cellular immune responses in an experimental scrub typhus rhesus macaque model and human populations. Whole cell antigen for O. tsutsugamushi (OT-WCA was prepared by heat inactivation of Karp-strain bacteria. Rhesus macaques were infected intradermally with O. tsutsugamushi. Freshly isolated peripheral blood mononuclear cells (PBMC from infected (n = 10 and uninfected animals (n = 5 were stimulated with OT-WCA, and IFN-γ secreting cells quantitated by ELISpot assay at five time points over 28 days. PBMC were then assayed from people in a scrub typhus-endemic region of Thailand (n = 105 and responses compared to those from a partially exposed population in a non-endemic region (n = 14, and to a naïve population in UK (n = 12. Mean results at Day 0 prior to O. tsutsugamushi infection were 12 (95% CI 0-25 and 15 (2-27 spot-forming cells (SFC/106 PBMC for infected and control macaques respectively. Strong O. tsutsugamushi-specific IFN-γ responses were seen post infection, with ELISpot responses 20-fold higher than baseline at Day 7 (mean 235, 95% CI 200-270 SFC/106 PBMC, 105-fold higher at Day 14 (mean 1261, 95% CI 1,097-1,425 SFC/106 PBMC, 125-fold higher at Day 21 (mean 1,498, 95% CI 1,496-1,500 SFC/106 PBMC and 118-fold higher at

  6. Strong interferon-gamma mediated cellular immunity to scrub typhus demonstrated using a novel whole cell antigen ELISpot assay in rhesus macaques and humans.

    Science.gov (United States)

    Sumonwiriya, Manutsanun; Paris, Daniel H; Sunyakumthorn, Piyanate; Anantatat, Tippawan; Jenjaroen, Kemajittra; Chumseng, Suchintana; Im-Erbsin, Rawiwan; Tanganuchitcharnchai, Ampai; Jintaworn, Suthatip; Blacksell, Stuart D; Chowdhury, Fazle R; Kronsteiner, Barbara; Teparrukkul, Prapit; Burke, Robin L; Lombardini, Eric D; Richards, Allen L; Mason, Carl J; Jones, James W; Day, Nicholas P J; Dunachie, Susanna J

    2017-09-01

    Scrub typhus is a febrile infection caused by the obligate intracellular bacterium Orientia tsutsugamushi, which causes significant morbidity and mortality across the Asia-Pacific region. The control of this vector-borne disease is challenging due to humans being dead-end hosts, vertical maintenance of the pathogen in the vector itself, and a potentially large rodent reservoir of unclear significance, coupled with a lack of accurate diagnostic tests. Development of an effective vaccine is highly desirable. This however requires better characterization of the natural immune response of this neglected but important disease. Here we implement a novel IFN-γ ELISpot assay as a tool for studying O. tsutsugamushi induced cellular immune responses in an experimental scrub typhus rhesus macaque model and human populations. Whole cell antigen for O. tsutsugamushi (OT-WCA) was prepared by heat inactivation of Karp-strain bacteria. Rhesus macaques were infected intradermally with O. tsutsugamushi. Freshly isolated peripheral blood mononuclear cells (PBMC) from infected (n = 10) and uninfected animals (n = 5) were stimulated with OT-WCA, and IFN-γ secreting cells quantitated by ELISpot assay at five time points over 28 days. PBMC were then assayed from people in a scrub typhus-endemic region of Thailand (n = 105) and responses compared to those from a partially exposed population in a non-endemic region (n = 14), and to a naïve population in UK (n = 12). Mean results at Day 0 prior to O. tsutsugamushi infection were 12 (95% CI 0-25) and 15 (2-27) spot-forming cells (SFC)/106 PBMC for infected and control macaques respectively. Strong O. tsutsugamushi-specific IFN-γ responses were seen post infection, with ELISpot responses 20-fold higher than baseline at Day 7 (mean 235, 95% CI 200-270 SFC/106 PBMC), 105-fold higher at Day 14 (mean 1261, 95% CI 1,097-1,425 SFC/106 PBMC), 125-fold higher at Day 21 (mean 1,498, 95% CI 1,496-1,500 SFC/106 PBMC) and 118-fold higher at Day 28

  7. Heritability of antibody isotype and subclass responses to Plasmodium falciparum antigens.

    Directory of Open Access Journals (Sweden)

    Nancy O Duah

    2009-10-01

    Full Text Available It is important to understand the extent to which genetic factors regulate acquired immunity to common infections. A classical twin study design is useful to estimate the heritable component of variation in measurable immune parameters.This study assessed the relative heritability of different plasma antibody isotypes and subclasses (IgG1, IgG2, IgG3, IgG4, IgM, IgA and IgE naturally acquired to P. falciparum blood stage antigens AMA1, MSP1-19, MSP2 (two allelic types and MSP3 (two allelic types. Separate analyses were performed on plasma from 213 pairs of Gambian adult twins, 199 child twin pairs sampled in a dry season when there was little malaria transmission, and another set of 107 child twin pairs sampled at the end of the annual wet season when malaria was common. There were significantly positive heritability (h(2 estimates for 48% (20/42 of the specific antibody assays (for the seven isotypes and subclasses to the six antigens tested among the adults, 48% (20/42 among the children in the dry season and 31% (13/42 among the children in the wet season. In children, there were significant heritability estimates for IgG4 reactivity against each of the antigens, and this subclass had higher heritability than the other subclasses and isotypes. In adults, 75% (15/20 of the significantly heritable antigen-specific isotype responses were attributable to non-HLA class II genetic variation, whereas none showed a significant HLA contribution.Genome-wide approaches are now warranted to map the major genetic determinants of variable antibody isotype and subclass responses to malaria, alongside evaluation of their impact on infection and disease. Although plasma levels of IgG4 to malaria antigens are generally low, the exceptionally high heritability of levels of this subclass in children deserves particular investigation.

  8. Dissecting the T Cell Response: Proliferation Assays vs. Cytokine Signatures by ELISPOT

    Directory of Open Access Journals (Sweden)

    Magdalena Tary-Lehmann

    2012-05-01

    Full Text Available Chronic allograft rejection is in part mediated by host T cells that recognize allogeneic antigens on transplanted tissue. One factor that determines the outcome of a T cell response is clonal size, while another is the effector quality. Studies of alloimmune predictors of transplant graft survival have most commonly focused on only one measure of the alloimmune response. Because differing qualities and frequencies of the allospecific T cell response may provide distinctly different information we analyzed the relationship between frequency of soluble antigen and allo-antigen specific memory IFN-g secreting CD4 and CD8 T cells, their ability to secrete IL-2, and their proliferative capacity, while accounting for cognate and bystander proliferation. The results show proliferative responses primarily reflect on IL-2 production by antigen-specific T cells, and that proliferating cells in such assays entail a considerable fraction of bystander cells. On the other hand, proliferation (and IL-2 production did not reflect on the frequency of IFN-γ producing memory cells, a finding particularly accentuated in the CD8 T cell compartment. These data provide rationale for considering both frequency and effector function of pre-transplant T cell reactivity when analyzing immune predictors of graft rejection.

  9. Dissecting the T Cell Response: Proliferation Assays vs. Cytokine Signatures by ELISPOT

    Science.gov (United States)

    Anthony, Donald D.; Milkovich, Kimberly A.; Zhang, Wenji; Rodriguez, Benigno; Yonkers, Nicole L.; Tary-Lehmann, Magdalena; Lehmann, Paul V.

    2012-01-01

    Chronic allograft rejection is in part mediated by host T cells that recognize allogeneic antigens on transplanted tissue. One factor that determines the outcome of a T cell response is clonal size, while another is the effector quality. Studies of alloimmune predictors of transplant graft survival have most commonly focused on only one measure of the alloimmune response. Because differing qualities and frequencies of the allospecific T cell response may provide distinctly different information we analyzed the relationship between frequency of soluble antigen and allo-antigen specific memory IFN-γ secreting CD4 and CD8 T cells, their ability to secrete IL-2, and their proliferative capacity, while accounting for cognate and bystander proliferation. The results show proliferative responses primarily reflect on IL-2 production by antigen-specific T cells, and that proliferating cells in such assays entail a considerable fraction of bystander cells. On the other hand, proliferation (and IL-2 production) did not reflect on the frequency of IFN-γ producing memory cells, a finding particularly accentuated in the CD8 T cell compartment. These data provide rationale for considering both frequency and effector function of pre-transplant T cell reactivity when analyzing immune predictors of graft rejection. PMID:24710419

  10. Premarket evaluations of the IMDx C. difficile for Abbott m2000 Assay and the BD Max Cdiff Assay.

    Science.gov (United States)

    Stellrecht, K A; Espino, A A; Maceira, V P; Nattanmai, S M; Butt, S A; Wroblewski, D; Hannett, G E; Musser, K A

    2014-05-01

    Clostridium difficile-associated diarrhea is a well-recognized complication of antibiotic use. Historically, diagnosing C. difficile has been difficult, as antigen assays are insensitive and culture-based methods require several days to yield results. Nucleic acid amplification tests (NAATs) are quickly becoming the standard of care. We compared the performance of two automated investigational/research use only (IUO/RUO) NAATs for the detection of C. difficile toxin genes, the IMDx C. difficile for Abbott m2000 Assay (IMDx) and the BD Max Cdiff Assay (Max). A prospective analysis of 111 stool specimens received in the laboratory for C. difficile testing by the laboratory's test of record (TOR), the BD GeneOhm Cdiff Assay, and a retrospective analysis of 88 specimens previously determined to be positive for C. difficile were included in the study. One prospective specimen was excluded due to loss to follow-up discrepancy analysis. Of the remaining 198 specimens, 90 were positive by all three methods, 9 were positive by TOR and Max, and 3 were positive by TOR only. One negative specimen was initially inhibitory by Max. The remaining 95 specimens were negative by all methods. Toxigenic C. difficile culture was performed on the 12 discrepant samples. True C. difficile-positive status was defined as either positive by all three amplification assays or positive by toxigenic culture. Based on this definition, the sensitivity and specificity were 96.9% and 95% for Max and 92.8% and 100% for IMDx. In summary, both highly automated systems demonstrated excellent performance, and each has individual benefits, which will ensure that they will both have a niche in clinical laboratories.

  11. Serum CEA (carcino-embryonic antigen) monitoring after surgery for cancer of the rectum and colon

    International Nuclear Information System (INIS)

    Reginster, J.Y.; Desaive, C.; Collette, J.; Zangerle, P.F.; Denis, D.; Franchimont, P.

    1984-01-01

    Fifty four patients, operated for colorectal cancer have been followed up for 2 to 100 months after surgery by carcino-embryonic antigen (CEA) determinations and classical, clinical, biological, radiological, echographical, isotopical and tomoscanninvestigations. Each new serum sample has been assayed for CEA with previously collected samples within the same patients. This repetition of CEA on the same samples allows to check the good reproducibility of CEA radioimmunoassay (variation coefficient between assay is less than 10%) and to get a complete profile of CEA level evaluation within the same assay. There is a good correlation between clinical evolution and CEA levels. In 42 patients, CEA levels remained or became normal ( 20 ng ml) at the same time or before clinical and/or paraclinical evidences for metastases or local recurrence. These results showed CEA assay in a quantitative parameter to assess the follow-up of colorectal cancer complementary to clinical, biological, radiological, echographical and isotopical criterias [fr

  12. A Two-Step Lyssavirus Real-Time Polymerase Chain Reaction Using Degenerate Primers with Superior Sensitivity to the Fluorescent Antigen Test

    Directory of Open Access Journals (Sweden)

    Vanessa Suin

    2014-01-01

    Full Text Available A generic two-step lyssavirus real-time reverse transcriptase polymerase chain reaction (qRT-PCR, based on a nested PCR strategy, was validated for the detection of different lyssavirus species. Primers with 17 to 30% of degenerate bases were used in both consecutive steps. The assay could accurately detect RABV, LBV, MOKV, DUVV, EBLV-1, EBLV-2, and ABLV. In silico sequence alignment showed a functional match with the remaining lyssavirus species. The diagnostic specificity was 100% and the sensitivity proved to be superior to that of the fluorescent antigen test. The limit of detection was ≤1 50% tissue culture infectious dose. The related vesicular stomatitis virus was not recognized, confirming the selectivity for lyssaviruses. The assay was applied to follow the evolution of rabies virus infection in the brain of mice from 0 to 10 days after intranasal inoculation. The obtained RNA curve corresponded well with the curves obtained by a one-step monospecific RABV-qRT-PCR, the fluorescent antigen test, and virus titration. Despite the presence of degenerate bases, the assay proved to be highly sensitive, specific, and reproducible.

  13. Increased seroreactivity to glioma-expressed antigen 2 in brain tumor patients under radiation.

    Directory of Open Access Journals (Sweden)

    Sabrina M Heisel

    Full Text Available BACKGROUND: Surgery and radiation are the mainstays of therapy for human gliomas that are the most common primary brain tumors. Most recently, cell culture and animal studies provided the first convincing evidence that radiation not only eliminates tumor cells, but also modulates the immune response and likely improves anti-tumor immunotherapy. METHODOLOGY/PRINCIPAL FINDINGS: We present an in vivo study that analyzes the effects of radiation on the immune response in tumor patients. As readout system, we utilized the reactivity of glioma patients' sera against antigen GLEA2 as the most frequent antigen immunogenic in glioblastoma patients. We established an ELISA assay to analyze reactivity of 24 glioblastoma patients over a period of several months. As control we used 30 sera from healthy donors as well as 30 sera from lung cancer patients. We compared the course of GLEA2 seroreactivity at different times prior, during and after radiation. The GLEA2 seroreactivity was increased by the time of surgery, decreased after surgery, increased again under radiation, and slightly decreased after radiation. CONCLUSIONS/SIGNIFICANCE: Our results provide in vivo evidence for an increased antibody response against tumor antigens under radiation. Antigens that become immunogenic with an increased antibody response as result of radiation can serve as ideal targets for immunotherapy of human tumors.

  14. Chlorphenesin: an antigen-associated immunosuppressant.

    Science.gov (United States)

    Whang, H Y; Neter, E

    1970-07-01

    Chlorphenesin (3-p-chlorophenoxy-1,2-propanediol), when injected intravenously together with either of two common bacterial antigens, inhibits the antibody response of the rabbit. The antigens studied are those common to Enterobacteriaceae and to gram-positive bacteria. The immunosuppression is contingent upon incubation of chlorphenesin and antigen in vitro prior to administration, since separate injection of antigen and inhibitor or of mixtures without prior incubation yields undiminished antibody response. Chlorphenesin, as shown by hemagglutination-inhibition tests, does not alter the antigenic determinants, because antibody neutralization occurs in the presence or absence of the drug. The immunosuppressive effect is reversible, since precipitation of chlorphenesin at 4 C substantially restores immunogenicity. Animals immunized with antigen-drug mixtures, which fail to respond with significant antibody production, nonetheless are immunologically primed. It is concluded that chlorphenesin represents another example of antigen-associated immunosuppressants.

  15. Clinical performance of LOCI™-based tumor marker assays for tumor markers CA 15-3, CA 125, CEA, CA 19-9 and AFP in gynecological cancers.

    Science.gov (United States)

    Dolscheid-Pommerich, Ramona C; Keyver-Paik, Mignon; Hecking, Thomas; Kuhn, Walther; Hartmann, Gunther; Stoffel-Wagner, Birgit; Holdenrieder, Stefan

    2017-10-01

    Evidence is sparse regarding the clinical performance of luminescent oxygen channeling immunoassays-based tumor marker assays in gynecological cancer. Analyzing serum samples of 336 patients with Dimension™Vista1500, we investigated the diagnostic power of carbohydrate antigen 15-3, carbohydrate antigen 125, carcinoembryonic antigen, carbohydrate antigen 19-9, and alpha-fetoprotein in patients suffering from different types of gynecological cancer and precancerous gynecological diseases and compared findings to appropriate control groups. The cohort comprised 177 female patients with gynecological cancers (73 breast, 22 cervical, 16 endometrial, 17 vulva, and 49 ovarian cancers), 26 patients with precancerous gynecological diseases (11 vulva, 4 cervical, and 10 breast), 109 patients with benign gynecological diseases, and 24 healthy controls. Discriminative power was assessed by areas under the curve in receiver operating characteristic curves, and sensitivities were determined at a fixed specificity of 95%. Levels of biomarkers in healthy controls were in the expected ranges and a discriminative power between gynecological cancers and healthy controls was observed for several tumor markers. Established tumor type-associated markers were elevated in specific gynecological cancers and benign controls as well as within precancerous gynecological diseases and healthy control group. In ovarian cancer, carbohydrate antigen 125 and carbohydrate antigen 15-3 were significantly elevated compared to the respective benign diseases. Carbohydrate antigen 125 was the most conclusive marker (area under the curve = 0.86% and 77.6% sensitivity at 95% specificity). In breast cancer, carcinoembryonic antigen and carbohydrate antigen 15-3 were significantly higher than in the respective benign diseases. Carcinoembryonic antigen achieved the most conclusive area under the curve (0.65) with 31.5% sensitivity at 95% specificity. None of the investigated markers was found to be of

  16. Analysis of JC virus DNA replication using a quantitative and high-throughput assay

    Science.gov (United States)

    Shin, Jong; Phelan, Paul J.; Chhum, Panharith; Bashkenova, Nazym; Yim, Sung; Parker, Robert; Gagnon, David; Gjoerup, Ole; Archambault, Jacques; Bullock, Peter A.

    2015-01-01

    Progressive Multifocal Leukoencephalopathy (PML) is caused by lytic replication of JC virus (JCV) in specific cells of the central nervous system. Like other polyomaviruses, JCV encodes a large T-antigen helicase needed for replication of the viral DNA. Here, we report the development of a luciferase-based, quantitative and high-throughput assay of JCV DNA replication in C33A cells, which, unlike the glial cell lines Hs 683 and U87, accumulate high levels of nuclear T-ag needed for robust replication. Using this assay, we investigated the requirement for different domains of T-ag, and for specific sequences within and flanking the viral origin, in JCV DNA replication. Beyond providing validation of the assay, these studies revealed an important stimulatory role of the transcription factor NF1 in JCV DNA replication. Finally, we show that the assay can be used for inhibitor testing, highlighting its value for the identification of antiviral drugs targeting JCV DNA replication. PMID:25155200

  17. Rapid antigen detection test for respiratory syncytial virus diagnosis as a diagnostic tool

    Directory of Open Access Journals (Sweden)

    Flávio da Silva Mesquita

    2017-05-01

    Full Text Available Objective: The aim of this study was to evaluate the QuickVue® RSV Test Kit (QUIDEL Corp, CA, USA as a screening tool for respiratory syncytial virus in children with acute respiratory disease in comparison with the indirect immunofluorescence assay as gold standard. In Brazil, rapid antigen detection tests for respiratory syncytial virus are not routinely utilized as a diagnostic tool, except for the diagnosis of dengue and influenza. Methods: The authors retrospectively analyzed 486 nasopharyngeal aspirate samples from children under age 5 with acute respiratory infection, between December 2013 and August 2014, the samples were analyzed by indirect immunofluorescence assay and QuickVue® RSV Test kit. Samples with discordant results were analyzed by real time PCR and nucleotide sequencing. Results: From 313 positive samples by immunofluorescence assays, 282 (90% were also positive by the rapid antigen detection test, two were positive only by rapid antigen detection test, 33 were positive only by immunofluorescence assays, and 171 were positive by both methods. The 35 samples with discordant results were analyzed by real time PCR; the two samples positive only by rapid antigen detection test and the five positive only by immunofluorescence assays were also positive by real time PCR. There was no relation between the negativity by QuickVue® RSV Test and viral load or specific strain. The QuickVue® RSV Test showed sensitivity of 90%, specificity of 98.8%, predictive positive value of 99.3%, and negative predictive value of 94.6%, with accuracy of 93.2% and agreement κ index of 0.85 in comparison to immunofluorescence assay. Conclusions: This study demonstrated that the QuickVue® RSV Test Kit can be effective in early detection of Respiratory syncytial virus in nasopharyngeal aspirate and is reliable for use as a diagnostic tool in pediatrics. Resumo: Objetivo: Avaliar o teste QuickVue® RSV Test Kit (QUIDEL Corp, CA, EUA para o diagn

  18. Modification of a deoxynivalenol-antigen-mimicking nanobody to improve immunoassay sensitivity by site-saturation mutagenesis.

    Science.gov (United States)

    Qiu, Yu-Lou; He, Qing-Hua; Xu, Yang; Wang, Wei; Liu, Yuan-Yuan

    2016-01-01

    A nanobody (N-28) which can act as a deoxynivalenol (DON) antigen has been generated, and its residues Thr102-Ser106 were identified to bind with anti-DON monoclonal antibody by alanine-scanning mutagenesis. Site-saturation mutagenesis was used to analyze the plasticity of five residues and to improve the sensitivity of the N-28-based immunoassay. After mutagenesis, three mutants were selected by phage immunoassay and were sequenced. The half-maximal inhibitory concentrations of the immunoassay based on mutants N-28-T102Y, N-28-V103L, and N-28-Y105F were 24.49 ± 1.0, 51.83 ± 2.5, and 35.65 ± 1.6 ng/mL, respectively, showing the assay was, respectively, 3.2, 1.5, and 2.2 times more sensitive than the wild-type-based assay. The best mutant, N-28-T102Y, was used to develop a competitive phage ELISA to detect DON in cereals with high specificity and accuracy. In addition, the structural properties of N-28-T102Y and N-28 were investigated, revealing that the affinity of N-28-T102Y decreased because of increased steric hindrance with the large side chain. The lower-binding-affinity antigen mimetic may contribute to the improvement of the sensitivity of competitive immunoassays. These results demonstrate that nanobodies would be a favorable tool for engineering. Moreover, our results have laid a solid foundation for site-saturation mutagenesis of antigen-mimicking nanobodies to improve immunoassay sensitivity for small molecules.

  19. Genetic and antigenic characterization of novel pestivirus genotypes: implications for classification

    International Nuclear Information System (INIS)

    Becher, Paul; Avalos Ramirez, Ramiro; Orlich, Michaela; Cedillo Rosales, Sibilina; Koenig, Matthias; Schweizer, Matthias; Stalder, Hanspeter; Schirrmeier, Horst; Thiel, Heinz-Juergen

    2003-01-01

    Currently, the genus Pestivirus comprises the four approved species Bovine viral diarrhea virus 1 (BVDV-1), BVDV-2, Classical swine fever virus (CSFV), and Border disease virus (BDV) and one tentative fifth species represented by a single strain (H138) isolated from a giraffe in Kenya more than 30 years ago. To further address the issue of heterogeneity of pestiviruses we have determined the entire N pro and E2 coding sequences for several new pestivirus isolates. Interestingly, phylogenetic analysis revealed that one pestivirus isolated in the 1990s in Africa is closely related to strain H138. Moreover, several novel pestiviruses isolated from sheep group together with the previously described strain V60 (Reindeer-1) isolated from a reindeer, whereas one ovine pestivirus strain (Gifhorn) significantly differs from all previously described pestiviruses, including BDV. We propose to term these mainly sheep-derived pestiviruses BDV-2 (V60-like isolates) and BDV-3 (Gifhorn); consequently, the 'classical' BDV isolates should be termed BDV-1. As an additional criterion for segregation of pestiviruses, the antigenic relatedness of pestivirus isolates covering all observed major genotypes was studied by cross-neutralization assays. Analysis of the antigenic similarities indicated the presence of seven major antigenic groups corresponding to BVDV-1, BVDV-2, CSFV, BDV-1, BDV-2, BDV-3, and 'giraffe'. Taking into account the host origin, the lack of differences concerning the course of disease, and the results of our genetic and antigenic analyses, we suggest that BDV-1, BDV-2, and BDV-3 should be considered as major genotypes within the species BDV

  20. Thermometric enzyme linked immunosorbent assay in continuous flow system: optimization and evaluation using human serum albumin as a model system.

    Science.gov (United States)

    Borrebaeck, C; Börjeson, J; Mattiasson, B

    1978-06-15

    Thermometric enzyme-linked immunosorbent assay (TELISA) is described. After the procedure of optimization, human serum albumin was assayed using anti-human serum albumin bound to Sepharose CL 4-B in the enzyme thermistor unit and catalase as label on the free antigen. The model system was used for assays down to 10(-13)M and the preparation of immobilized antibodies was used repeatedly up to 100 times. Comparative studies of the TELISA technique with bromocresol green, immunoturbidimetric and rocket immunoelectrophoretic methods were carried out and showed that TELISA could be used as an alternative method.

  1. A novel synthetic peptide microarray assay detects Chlamydia species-specific antibodies in animal and human sera.

    Science.gov (United States)

    Sachse, Konrad; Rahman, Kh Shamsur; Schnee, Christiane; Müller, Elke; Peisker, Madlen; Schumacher, Thomas; Schubert, Evelyn; Ruettger, Anke; Kaltenboeck, Bernhard; Ehricht, Ralf

    2018-03-16

    Serological analysis of Chlamydia (C.) spp. infections is still mainly based on micro-immunofluorescence and ELISA. To overcome the limitations of conventional serology, we have designed a novel microarray carrying 52 synthetic peptides representing B-cell epitopes from immunodominant proteins of all 11 chlamydial species. The new assay has been validated using monospecific mouse hyperimmune sera. Subsequently, serum samples from cattle, sheep and humans with a known history of chlamydial infection were examined. For instance, the specific humoral response of sheep to treatment with a C. abortus vaccine has been visualized against a background of C. pecorum carriership. In samples from humans, dual infection with C. trachomatis and C. pneumoniae could be demonstrated. The experiments revealed that the peptide microarray assay was capable of simultaneously identifying specific antibodies to each Chlamydia spp. The actual assay represents an open platform test that can be complemented through future advances in Chlamydia proteome research. The concept of the highly parallel multi-antigen microarray proven in this study has the potential to enhance our understanding of antibody responses by defining not only a single quantitative response, but also the pattern of this response. The added value of using peptide antigens will consist in unprecedented serodiagnostic specificity.

  2. A three-layer immunoradiometric assay for antibodies in different immunoglobulin classes and its application to the detection of chicken thyroglobulin autoantibodies and of antibodies to sheep erythrocytes

    International Nuclear Information System (INIS)

    Carvalho, L.C.P. de; Roitt, I.M.; Wick, G.

    1980-01-01

    A versatile solid-phase assay for detection of antibodies in different immunoglobulin classes is described. The assay has been applied to: (1) the detection of IgG and IgM antithyroglobulin autoantibodies in chickens with spontaneous autoimmune thyroiditis, and (2) the detection of anti-sheep cell antibodies in normal chickens. Thyroglobulin-coated plastic tubes or formaldehyde-fixed sheep erythrocytes were used as the solid phase. Antisera were added in succession to the solid-phase antigen so as to form 3 antibody layers: (1) chicken antibody against the solid-phase antigen; (2) heavy-chain-specific rabbit anti-chicken immunoglobulin; and (3) 125 I-labelled goat anti-rabbit immunoglobulin. The assay is suitable for routine determinations on large numbers of samples; its sensitivity enables small volumes of serum to be tested and allows considerable economy in the use of valuable class-specific antisera. The radiolabelled reagent can be readily applied to other assays employing rabbit antisera. (Auth.)

  3. Development and evaluation of single domain antibodies for vaccinia and the L1 antigen.

    Directory of Open Access Journals (Sweden)

    Scott A Walper

    Full Text Available There is ongoing interest to develop high affinity, thermal stable recognition elements to replace conventional antibodies in biothreat detection assays. As part of this effort, single domain antibodies that target vaccinia virus were developed. Two llamas were immunized with killed viral particles followed by boosts with the recombinant membrane protein, L1, to stimulate the immune response for envelope and membrane proteins of the virus. The variable domains of the induced heavy chain antibodies were selected from M13 phage display libraries developed from isolated RNA. Selection via biopanning on the L1 antigen produced single domain antibodies that were specific and had affinities ranging from 4×10(-9 M to 7.0×10(-10 M, as determined by surface plasmon resonance. Several showed good ability to refold after heat denaturation. These L1-binding single domain antibodies, however, failed to recognize the killed vaccinia antigen. Useful vaccinia binding single domain antibodies were isolated by a second selection using the killed virus as the target. The virus binding single domain antibodies were incorporated in sandwich assays as both capture and tracer using the MAGPIX system yielding limits of detection down to 4×10(5 pfu/ml, a four-fold improvement over the limit obtained using conventional antibodies. This work demonstrates the development of anti-vaccinia single domain antibodies and their incorporation into sandwich assays for viral detection. It also highlights the properties of high affinity and thermal stability that are hallmarks of single domain antibodies.

  4. Detection of viral antigens by solid phase radioimmunoassay on polyethylene film

    Energy Technology Data Exchange (ETDEWEB)

    Prokudina, E N; Semenova, N P; Zhdanov, V M

    1986-04-01

    Polyethylene film, without any pretreatment, may serve as a solid phase (SP) for RIA. Viral antigens (HBsAg, and influenza virus) are detected by SP-RIA on the film with a sensitivity of about 2-3 ng/ml or 40-60 pg/assay. The use of polyethylene film allows one to record RIA autographically. The use of micro amounts of reagents and specimens tested is an added advantage. No special equipment is necessary, the method is inexpensive, easy to perform and may be used for mass screening. (Auth.). 7 refs.; 4 figs.

  5. Prostataspecifikt antigen, sure fosfataser og rektaleksploration i diagnostik af cancer prostatae

    DEFF Research Database (Denmark)

    Ristorp Andersen, Betina; Knorr, Ulla Benedichte Søsted; Brasso, Klaus

    1997-01-01

    Eleven hundred and seven patients referred for urological evaluation including measurement of serumprostate specific antigen (PSA) measurement are reviewed. Prostate cancer was diagnosed in 105 patients. PSA was found to be superior to prostatic acid phosphatase in the discrimination between...... prostate cancer and benign prostatic conditions. In 105 patients with newly diagnosed prostate cancer, scintigraphic evidence of osseous metastases was found in thirty-seven. No patients with a serum PSA value less than three times the upper normal limit of the assay had a positive bone scan. Isotope bone...

  6. Evaluation of a new serological test for syphilis based on chemiluminescence assay in a tertiary care hospital.

    Science.gov (United States)

    Tiwari, Aseem K; Pandey, Prashant K; Dara, Ravi C; Rawat, Ganesh S; Raina, Vimarsh; Bhargava, Richa

    2015-01-01

    Syphilis is a transfusion transmissible infections and it is mandatory to do serological test for syphilis (STS) on all donor blood samples. STS is usually based on detection of antibodies against the cardiolipin-lecithin antigen or against the Treponema-specific antigen. STS with good sensitivity and specificity helps enhance blood safety and consolidation of STS along with other transfusion transmittable infections such as human immunodeficiency virus, hepatitis-C virus, and hepatitis-B virus helps in reducing the errors and enhances efficiency. This study was designed to evaluate the performance of newly introduced VITROS(®) syphilis Treponema pallidum agglutination (TPA) assay based on enhanced chemiluminescence principle for its analytical performance for use as a STS on donor blood samples at a tertiary care health center in National Capital Region, India. A total of 108 random blood units collected from the donors (both voluntary and replacement donors) and 28 known syphilis sero-reactive samples stored at -20°C, were used to evaluate the performance of VITROS(®) syphilis TPA assay based on enhanced chemiluminescence assay on VITROS(®) ECiQ immunodiagnostics system along with its analytical performance in terms of its sensitivity, precision, cross-reactivity and interference studies. VITROS(®) syphilis TPA showed 100% sensitivity and specificity with precision (20 days study) of endogenous interfering substances like free hemoglobin or fats. Performance of the VITROS(®) syphilis TPA assay meets the requirements for its use as STS in blood bank, thus allowing consolidation with other transfusion transmittable infections screening assay on chemiluminescence platform, which is highly valuable for optimizing workflow and efficiency.

  7. Dendritic cells induce specific cytotoxic T lymphocytes against prostate cancer TRAMP-C2 cells loaded with freeze- thaw antigen and PEP-3 peptide.

    Science.gov (United States)

    Liu, Xiao-Qi; Jiang, Rong; Li, Si-Qi; Wang, Jing; Yi, Fa-Ping

    2015-01-01

    Prostate cancer is the most common cancer in men. In this study, we investigated immune responses of cytotoxic T lymphocytes (CTLs) against TRAMP-C2 prostate cancer cells after activation by dendritic cells (DCs) loaded with TRAMP-C2 freeze-thaw antigen and/or PEP-3 peptide in vitro. Bone marrow-derived DC from the bone marrow of the C57BL/6 were induced to mature by using the cytokine of rhGM-CSF and rhIL-4, and loaded with either the freeze-thaw antigen or PEP-3 peptide or both of them. Maturation of DCs was detected by flow cytometry. The killing efficiency of the CTLs on TRAMP-C2 cells were detected by flow cytometry, CCK8, colony formation, transwell migration, and wound-healing assay. The levels of the IFN-γ, TNF-β and IL-12 were measured by enzyme-linked immunosorbent assay (ELISA). Compared with the unloaded DCs, the loaded DCs had significantly increased expression of several phenotypes related to DC maturation. CTLs activated by DCs loaded with freeze-thaw antigen and PEP-3 peptide had more evident cytotoxicity against TRAMP-C2 cells in vitro. The secretion levels of IFN-γ, TNF-β and IL-12, secreted by DCs loaded with antigen and PEP-3 and interaction with T cells, were higher than in the other groups. Our results suggest that the CTLs activated by DCs loaded with TRAMP-C2 freeze-thaw antigen and PEP-3 peptide exert a remarkable killing efficiency against TRAMP-C2 cells in vitro.

  8. Schistosome circulating anodic antigen in serum of individuals infected with Schistosoma japonicum from the Philippines before and after chemotherapy with praziquantel

    NARCIS (Netherlands)

    van 't Wout, A. B.; de Jonge, N.; Tiu, W. U.; Garcia, E. E.; Mitchell, G. F.; Deelder, A. M.

    1992-01-01

    The presence of the schistosome circulating anodic antigen (CAA) in serum of patients infected with Schistosoma japonicum from The Philippines has been investigated using an enzyme-linked immunosorbent assay (ELISA). Serum samples were tested from 48 patients who excreted S. japonicum eggs, 9

  9. Increased levels of IgA antibodies against CRA and FRA recombinant antigens of Trypanosoma cruzi differentiate digestive forms of Chagas disease.

    Science.gov (United States)

    Vasconcelos, Romero H T; Amaral, Fábio N; Cavalcanti, Maria G A M; Silva, Edimilson D; Ferreira, Antonio G P; Morais, Clarice N L; Gomes, Yara M

    2010-10-01

    In the chronic phase of Chagas disease, individuals infected by Trypanosoma cruzi may be asymptomatic or may present cardiac and/or digestive complications. Our aim here was to analyze the relationship between the presence of specific immunoglobulin A antibodies and the different chronic clinical forms of Chagas disease using two recombinant antigens of Trypanosoma cruzi, cytoplasmatic repetitive antigen and flagellar repetitive antigen. The association of this immunoglobulin isotype with the digestive and cardio-digestive forms of the disease determined by indirect enzyme-linked immunosorbent assay, strongly suggests that IgA antibodies against these recombinant antigens of T. cruzi can be used as an immunological marker of the digestive alterations caused by Chagas disease. The tests performed in this study show that it is possible to differentiate digestive forms of Chagas disease. The knowledge provided by these results may help physicians to manage early alterations in the digestive tract of patients with the indeterminate or cardiac forms of Chagas disease. Prospective studies, however, with follow-up of the patients that presenting with high levels of immunoglobulin A against cytoplasmatic repetitive antigen and flagellar repetitive antigen recombinant antigens, need to be conducted to confirm this hypothesis. 2010 American Society for Histocompatibility and Immunogenetics. Published by Elsevier Inc. All rights reserved.

  10. Analytical Validation of the ReEBOV Antigen Rapid Test for Point-of-Care Diagnosis of Ebola Virus Infection.

    Science.gov (United States)

    Cross, Robert W; Boisen, Matthew L; Millett, Molly M; Nelson, Diana S; Oottamasathien, Darin; Hartnett, Jessica N; Jones, Abigal B; Goba, Augustine; Momoh, Mambu; Fullah, Mohamed; Bornholdt, Zachary A; Fusco, Marnie L; Abelson, Dafna M; Oda, Shunichiro; Brown, Bethany L; Pham, Ha; Rowland, Megan M; Agans, Krystle N; Geisbert, Joan B; Heinrich, Megan L; Kulakosky, Peter C; Shaffer, Jeffrey G; Schieffelin, John S; Kargbo, Brima; Gbetuwa, Momoh; Gevao, Sahr M; Wilson, Russell B; Saphire, Erica Ollmann; Pitts, Kelly R; Khan, Sheik Humarr; Grant, Donald S; Geisbert, Thomas W; Branco, Luis M; Garry, Robert F

    2016-10-15

     Ebola virus disease (EVD) is a severe viral illness caused by Ebola virus (EBOV). The 2013-2016 EVD outbreak in West Africa is the largest recorded, with >11 000 deaths. Development of the ReEBOV Antigen Rapid Test (ReEBOV RDT) was expedited to provide a point-of-care test for suspected EVD cases.  Recombinant EBOV viral protein 40 antigen was used to derive polyclonal antibodies for RDT and enzyme-linked immunosorbent assay development. ReEBOV RDT limits of detection (LOD), specificity, and interference were analytically validated on the basis of Food and Drug Administration (FDA) guidance.  The ReEBOV RDT specificity estimate was 95% for donor serum panels and 97% for donor whole-blood specimens. The RDT demonstrated sensitivity to 3 species of Ebolavirus (Zaire ebolavirus, Sudan ebolavirus, and Bundibugyo ebolavirus) associated with human disease, with no cross-reactivity by pathogens associated with non-EBOV febrile illness, including malaria parasites. Interference testing exhibited no reactivity by medications in common use. The LOD for antigen was 4.7 ng/test in serum and 9.4 ng/test in whole blood. Quantitative reverse transcription-polymerase chain reaction testing of nonhuman primate samples determined the range to be equivalent to 3.0 × 10 5 -9.0 × 10 8 genomes/mL.  The analytical validation presented here contributed to the ReEBOV RDT being the first antigen-based assay to receive FDA and World Health Organization emergency use authorization for this EVD outbreak, in February 2015. © The Author 2016. Published by Oxford University Press for the Infectious Diseases Society of America. All rights reserved. For permissions, e-mail journals.permissions@oup.com.

  11. Identification of "tumor-associated" nucleolar antigens in human urothelial cancer.

    Science.gov (United States)

    Yu, D; Pietro, T; Jurco, S; Scardino, P T

    1987-09-01

    Nucleoli isolated from HeLa S3 cells were used to produce rabbit antisera capable of binding nucleoli of transitional cell carcinomas (TCCa) of the bladder. Cross-reactivity of the rabbit antiserum with normal nucleoli was reduced by absorption with fetal calf serum, normal human serum, and human placental nucleoli. This antinucleolar antiserum exhibited strong reactivity in immunoperoxidase assays performed on specimens of human bladder cancer. In frozen tissue sections of 24 patients with TCCa and eight individuals without tumor, nucleolar staining was observed in all malignant specimens, but was not observed in seven of the normal specimens. Cytologic examination of bladder washing specimens from 47 normal individuals showed absence of nucleolar staining in 43 (91%) of 47 normal specimens while 12 (86%) of 14 specimens from patients with TCCa were positive. These results suggest that there are antigens associated with the nucleoli of HeLa cells and transitional cell carcinomas which are generally absent (or in low concentration) in normal human urothelial cells, and that antisera to these antigens may be useful in the cytologic diagnosis of human transitional cell carcinoma.

  12. Immunogenetic mechanisms driving norovirus GII.4 antigenic variation.

    Directory of Open Access Journals (Sweden)

    Lisa C Lindesmith

    Full Text Available Noroviruses are the principal cause of epidemic gastroenteritis worldwide with GII.4 strains accounting for 80% of infections. The major capsid protein of GII.4 strains is evolving rapidly, resulting in new epidemic strains with altered antigenic potentials. To test if antigenic drift may contribute to GII.4 persistence, human memory B cells were immortalized and the resulting human monoclonal antibodies (mAbs characterized for reactivity to a panel of time-ordered GII.4 virus-like particles (VLPs. Reflecting the complex exposure history of the volunteer, human anti-GII.4 mAbs grouped into three VLP reactivity patterns; ancestral (1987-1997, contemporary (2004-2009, and broad (1987-2009. NVB 114 reacted exclusively to the earliest GII.4 VLPs by EIA and blockade. NVB 97 specifically bound and blocked only contemporary GII.4 VLPs, while NBV 111 and 43.9 exclusively reacted with and blocked variants of the GII.4.2006 Minerva strain. Three mAbs had broad GII.4 reactivity. Two, NVB 37.10 and 61.3, also detected other genogroup II VLPs by EIA but did not block any VLP interactions with carbohydrate ligands. NVB 71.4 cross-neutralized the panel of time-ordered GII.4 VLPs, as measured by VLP-carbohydrate blockade assays. Using mutant VLPs designed to alter predicted antigenic epitopes, two evolving, GII.4-specific, blockade epitopes were mapped. Amino acids 294-298 and 368-372 were required for binding NVB 114, 111 and 43.9 mAbs. Amino acids 393-395 were essential for binding NVB 97, supporting earlier correlations between antibody blockade escape and carbohydrate binding variation. These data inform VLP vaccine design, provide a strategy for expanding the cross-blockade potential of chimeric VLP vaccines, and identify an antibody with broadly neutralizing therapeutic potential for the treatment of human disease. Moreover, these data support the hypothesis that GII.4 norovirus evolution is heavily influenced by antigenic variation of neutralizing

  13. Lewis antigen mediated adhesion of freshly removed human bladder tumors to E-selectin

    DEFF Research Database (Denmark)

    Skorsteensgaard, Karna; Vestergaard, Else Marie; Langkilde, Niels

    1999-01-01

    PURPOSE: Twenty fresh surgical specimens of human bladder tumors were tested for their ability to adhere to recombinant P and E-selectin. The adhesion was correlated to immunological detection of carbohydrate structures. MATERIALS AND METHODS: A static titertray assay with immobilized selectins.......003), whereas no correlation was found to secretor and Lewis genotypes. CONCLUSIONS: These data on clinical specimens indicate that Lewis antigen mediated E-selectin adhesion may play a role in the human bladder cancer disease....

  14. Enhancement of MHC-I antigen presentation via architectural control of pH-responsive, endosomolytic polymer nanoparticles.

    Science.gov (United States)

    Wilson, John T; Postma, Almar; Keller, Salka; Convertine, Anthony J; Moad, Graeme; Rizzardo, Ezio; Meagher, Laurence; Chiefari, John; Stayton, Patrick S

    2015-03-01

    Protein-based vaccines offer a number of important advantages over organism-based vaccines but generally elicit poor CD8(+) T cell responses. We have previously demonstrated that pH-responsive, endosomolytic polymers can enhance protein antigen delivery to major histocompatibility complex class I (MHC-I) antigen presentation pathways thereby augmenting CD8(+) T cell responses following immunization. Here, we describe a new family of nanocarriers for protein antigen delivery assembled using architecturally distinct pH-responsive polymers. Reversible addition-fragmentation chain transfer (RAFT) polymerization was used to synthesize linear, hyperbranched, and core-crosslinked copolymers of 2-(N,N-diethylamino)ethyl methacrylate (DEAEMA) and butyl methacrylate (BMA) that were subsequently chain extended with a hydrophilic N,N-dimethylacrylamide (DMA) segment copolymerized with thiol-reactive pyridyl disulfide (PDS) groups. In aqueous solution, polymer chains assembled into 25 nm micellar nanoparticles and enabled efficient and reducible conjugation of a thiolated protein antigen, ovalbumin. Polymers demonstrated pH-dependent membrane-destabilizing activity in an erythrocyte lysis assay, with the hyperbranched and cross-linked polymer architectures exhibiting significantly higher hemolysis at pH ≤ 7.0 than the linear diblock. Antigen delivery with the hyperbranched and cross-linked polymer architecture enhanced in vitro MHC-I antigen presentation relative to free antigen, whereas the linear construct did not have a discernible effect. The hyperbranched system elicited a four- to fivefold increase in MHC-I presentation relative to the cross-linked architecture, demonstrating the superior capacity of the hyperbranched architecture in enhancing MHC-I presentation. This work demonstrates that the architecture of pH-responsive, endosomolytic polymers can have dramatic effects on intracellular antigen delivery, and offers a promising strategy for enhancing CD8(+) T cell

  15. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  16. Whole blood interferon-gamma assay for baseline tuberculosis screening among Japanese healthcare students.

    Directory of Open Access Journals (Sweden)

    Katsuyuki Hotta

    Full Text Available BACKGROUND: The whole blood interferon-gamma assay (QuantiFERON-TB-2G; QFT has not been fully evaluated as a baseline tuberculosis screening test in Japanese healthcare students commencing clinical contact. The aim of this study was to compare the results from the QFT with those from the tuberculin skin test (TST in a population deemed to be at a low risk for infection with Mycobacterium tuberculosis. METHODOLOGY/PRINCIPAL FINDINGS: Healthcare students recruited at Okayama University received both the TST and the QFT to assess the level of agreement between these two tests. The interleukin-10 levels before and after exposure to M tuberculosis-specific antigens (early-secreted antigenic target 6-kDa protein [ESAT-6] and culture filtrate protein 10 [CFP-10] were also measured. Of the 536 healthcare students, most of whom had been vaccinated with bacillus-Calmette-Guérin (BCG, 207 (56% were enrolled in this study. The agreement between the QFT and the TST results was poor, with positive result rates of 1.4% vs. 27.5%, respectively. A multivariate analysis also revealed that the induration diameter of the TST was not affected by the interferon-gamma concentration after exposure to either of the antigens but was influenced by the number of BCG needle scars (p = 0.046. The whole blood interleukin-10 assay revealed that after antigen exposure, the median increases in interleukin-10 concentration was higher in the subgroup with the small increase in interferon-gamma concentration than in the subgroup with the large increase in interferon-gamma concentration (0.3 vs. 0 pg/mL; p = 0.004. CONCLUSIONS/SIGNIFICANCE: As a baseline screening test for low-risk Japanese healthcare students at their course entry, QFT yielded quite discordant results, compared with the TST, probably because of the low specificity of the TST results in the BCG-vaccinated population. We also found, for the first time, that the change in the interleukin-10 level after exposure to

  17. Association Between PAI-1 Activity Levels and t-PA Antigen with Glycemic Status in Prediabetic Population

    Directory of Open Access Journals (Sweden)

    Andi Fachruddin Benyamin

    2016-11-01

    Full Text Available Aim: to evaluate an association between fibrinolysis defect and glycemic status in prediabetic population by assessing the levels of t-PA antigen and PAI-1 activity. Methods: it was an observational study with cross-sectional approach. There were 72 subjects aged 30-50 years who had met the inclusion criteria. The diagnosis of diabetes mellitus (DM and glycemic index were determined based on the American Diabetes Association (ADA criteria. The PAI-1 and t-PA antigen levels were measured quantitatively using enzyme-linked immunosorbent assay (ELISA. Analysis between the levels of t-PA antigen and PAI-1 activity was performed using ANOVA. Results: the t-PA antigen level was significantly higher in subjects with impaired glucose tolerance (IGT and impaired fasting blood glucose (IFBG as well as subject with impaired fasting blood glucose (IFBG than those with normal glucose tolerance (NGT (p=0.047. The PAI-1 activity was significantly higher in subjects with IGT, IFBG and subjects with IFBG than NGT (p=0.024. There was a significant association between glycemic status in prediabetic subjects and PAI-1 activity (p=0.04. Conclusion: the level of t-PA antigen and PAI-1 activity were significantly higher in prediabetic subjects than those with NGT; and there was a significant association between glycemic status in prediabetic subjects and PAI-1 activity.

  18. Monoclonal antibodies for use in an immunoradiometric assay for. cap alpha. -foetoprotein

    Energy Technology Data Exchange (ETDEWEB)

    Hunter, W.M.; Bennie, J.G. (Medical Research Council, Edinburgh (UK). Immunoassay Team); Brock, D.J.H.; Heyningen, V. van (Western General Hospital, Edinburgh (UK))

    1982-04-29

    The advantages offered by a mouse IgG/sub 1/ monoclonal antibody to human ..cap alpha..-foetoprotein (AFP) for the preparation of (/sup 125/I)antibody for use in an immunoradiometric assay (IRMA) have been investigated. The antibody was isolated from ascites fluid by sodium sulphate precipitation followed by gel filtration on Sephadex G-200. The freeze-dried powder and solutions thereof were stable and were used for iodination to 1 atom /sup 125/I/molecule antibody by the chloramine-T procedure. At high antigen concentrations 70-80% of the added (/sup 125/)Ab was present in the sandwich. Linear response curves in the range 1-100 ..mu..g antigen/l incubate were obtained when (/sup 125/I)Ab was in slight excess. In this region an Ag : Ab ratio 1.9 : 1 was obtained which is consistent with the saturation of a bifunctional antibody. Although non-specific binding (in the absence of antigen) was consistently <0.1% of added (/sup 125/I)Ab, this was the main factor in determining assay detection limits. The serum AFP levels from both non-pregnant and pregnant subjects as measured by the IRMA using the (/sup 125/I)monoclonal Ab and by radioimmunoassay (RIA) using a sheep antiserum to AFP were in excellent agreement. The IRMA was manipulatively simple, employed a shorter incubation time (2h), required shorter counting times than the RIA and gave a much wider working range. The provision of a monoclonal antibody for labelling removes the one major practicability barrier which otherwise limits the development and use of the potentially superior IRMA system.

  19. Improved detection of equine antibodies against Sarcocystis neurona using polyvalent ELISAs based on the parasite SnSAG surface antigens.

    Science.gov (United States)

    Yeargan, Michelle R; Howe, Daniel K

    2011-02-28

    Equine protozoal myeloencephalitis (EPM) is a common neurologic disease of horses that is caused by the apicomplexan pathogen Sarcocystis neurona. To help improve serologic diagnosis of S. neurona infection, we have modified existing enzyme-linked immunosorbent assays (ELISAs) based on the immunogenic parasite surface antigens SnSAG2, SnSAG3, and SnSAG4 to make the assays polyvalent, thereby circumventing difficulties associated with parasite antigenic variants and diversity in equine immune responses. Two approaches were utilized to achieve polyvalence: (1) mixtures of the individual recombinant SnSAGs (rSnSAGs) were included in single ELISAs; (2) a collection of unique SnSAG chimeras that fused protein domains from different SnSAG surface antigens into a single recombinant protein were generated for use in the ELISAs. These new assays were assessed using a defined sample set of equine sera and cerebrospinal fluids (CSFs) that had been characterized by Western blot and/or were from confirmed EPM horses. While all of the polyvalent ELISAs performed relatively well, the highest sensitivity and specificity (100%/100%) were achieved with assays containing the rSnSAG4/2 chimera (Domain 1 of SnSAG4 fused to SnSAG2) or using a mixture of rSnSAG3 and rSnSAG4. The rSnSAG4 antigen alone and the rSnSAG4/3 chimera (Domain 1 of SnSAG4 fused to Domain 2 of SnSAG3) exhibited the next best accuracy at 95.2% sensitivity and 100% specificity. Binding ratios and percent positivity (PP) ratios, determined by comparing the mean values for positive versus negative samples, showed that the most advantageous signal to noise ratios were provided by rSnSAG4 and the rSnSAG4/3 chimera. Collectively, our results imply that a polyvalent ELISA based on SnSAG4 and SnSAG3, whether as a cocktail of two proteins or as a single chimeric protein, can give optimal results in serologic testing of serum or CSF for the presence of antibodies against S. neurona. The use of polyvalent SnSAG ELISAs will

  20. Kinetic Consideration of AFP irma assay

    International Nuclear Information System (INIS)

    Aly, M. A.; Moustafa, K.A.

    2003-01-01

    Alpha-fetoprotein (AFP) is a glycoprotein produced by the yolk sac and later by the fetal liver during pregnancy. When the neural tube is not properly formed, by the fetal liver during pregnancy. When the neural tube is not properly formed, large amounts of AFP pass into the amniotic fluid and reach the mother's blood. During pregnancy, the major interest in AFP determination in maternal serum and amniotic fluid is on the early diagnosis of fetal abnormalities. AFP also used as a tumor marker for hepatocellular carcinoma. There are many different techniques for measuring AFP in blood, but the more accurate one is the immunoassay technique. The kinetics of the interaction between AFP antigen and two matched antibodies, one labeled with radioactive isotope 1 25I (tracer) and the other is unlabelled and attached to a solid support (tube), are studied using the more recently, two sites (sandwich) immunoradiometric assay (IRMA) technique. We present here a method for determining the rate constants, using an advanced computer program (RKY), which based on the nelder-mead optimization principle. The rate constant, at three variable temperatures and three different antigen concentrations, as well as the half time of exchange (t 1/2 ) were calculated

  1. Cellular immune response from Chagasic patients to CRA or FRA recombinant antigens of Trypanosoma cruzi.

    Science.gov (United States)

    Lorena, Virginia M B; Verçosa, Alinne F A; Machado, Raquel C A; Moitinho-Silva, Lucas; Cavalcanti, Maria G A; Silva, Edimilson D; Ferreira, Antonio G P; Correa-Oliveira, Rodrigo; Pereira, Valéria R A; Gomes, Yara M

    2008-01-01

    We propose to analyze the relation between the cellular immune response of Chagas' disease patients after in vitro stimulation of peripheral blood mononuclear cells (PBMC) with recombinant antigens cytoplasmatic repetitive antigen (CRA) or flagellar repetitive antigen (FRA) of T. cruzi and the chronic clinical forms of disease. Cells were stimulated using phytohemagglutinin, CRA, FRA, or a soluble antigen of Epimastigota (Ag-Epi) for 24 hr, 72 hr, or 6 days. The proliferation of cells was evaluated after 6 days of culture by quantification of incorporated 3H-thymidine. Cytokines were measured in the supernatants obtained after 24 hr (tumor necrosis factor [TNF]-alpha and interleukin [IL]-4), 72 hr (IL-10), and 6 days (interferon [IFN]-gamma) using enzyme-linked immunosorbent assay (ELISA). Cells of the Chagas patients stimulated with the recombinant antigens exhibited higher proliferation responses compared with that of non-Chagas (NC) individuals. However, when proliferation was compared between patients with the cardiac form (CF) or indeterminate form (IF), it was not possible to establish a difference in the response. So far as the cytokines secreted in the culture supernatants after stimulation in vitro with T. cruzi antigens were concerned, the results showed that CRA, as well as Epi-Ag, were able to stimulate the production of TNF-alpha and IFN-gamma in Chagas patients as compared with NC individuals. However, the cytokine levels after stimulation with the T. cruzi antigens were not different between the patients with CF and IF. CRA was capable of inducing a T helper type 1 (Th1) immune response, with elevated production of TNF-alpha and IFN-gamma in Chagas patients that are carriers of CF and IF clinical forms. (Copyright ) 2008 Wiley-Liss, Inc.

  2. Evaluation of multiplex assay platforms for detection of influenza hemagglutinin subtype specific antibody responses.

    Science.gov (United States)

    Li, Zhu-Nan; Weber, Kimberly M; Limmer, Rebecca A; Horne, Bobbi J; Stevens, James; Schwerzmann, Joy; Wrammert, Jens; McCausland, Megan; Phipps, Andrew J; Hancock, Kathy; Jernigan, Daniel B; Levine, Min; Katz, Jacqueline M; Miller, Joseph D

    2017-05-01

    Influenza hemagglutination inhibition (HI) and virus microneutralization assays (MN) are widely used for seroprevalence studies. However, these assays have limited field portability and are difficult to fully automate for high throughput laboratory testing. To address these issues, three multiplex influenza subtype-specific antibody detection assays were developed using recombinant hemagglutinin antigens in combination with Chembio, Luminex ® , and ForteBio ® platforms. Assay sensitivity, specificity, and subtype cross-reactivity were evaluated using a panel of well characterized human sera. Compared to the traditional HI, assay sensitivity ranged from 87% to 92% and assay specificity in sera collected from unexposed persons ranged from 65% to 100% across the platforms. High assay specificity (86-100%) for A(H5N1) rHA was achieved for sera from exposed or unexposed to hetorosubtype influenza HAs. In contrast, assay specificity for A(H1N1)pdm09 rHA using sera collected from A/Vietnam/1204/2004 (H5N1) vaccinees in 2008 was low (22-30%) in all platforms. Although cross-reactivity against rHA subtype proteins was observed in each assay platform, the correct subtype specific responses were identified 78%-94% of the time when paired samples were available for analysis. These results show that high throughput and portable multiplex assays that incorporate rHA can be used to identify influenza subtype specific infections. Published by Elsevier B.V.

  3. Reduced response to Epstein–Barr virus antigens by T-cells in systemic lupus erythematosus patients

    Science.gov (United States)

    Draborg, Anette Holck; Jacobsen, Søren; Westergaard, Marie; Mortensen, Shila; Larsen, Janni Lisander; Houen, Gunnar; Duus, Karen

    2014-01-01

    Objective Epstein–Barr virus (EBV) has for long been associated with systemic lupus erythematosus (SLE). In this study, we investigated the levels of latent and lytic antigen EBV-specific T-cells and antibodies in SLE patients. Methods T cells were analyzed by flow cytometry and antibodies were analyzed by enzyme-linked immunosorbent assay. Results SLE patients showed a significantly reduced number of activated (CD69) T-cells upon ex vivo stimulation with EBV nuclear antigen (EBNA) 1 or EBV early antigen diffuse (EBV-EA/D) in whole blood samples compared with healthy controls. Also, a reduced number of T-cells from SLE patients were found to produce interferon-γ upon stimulation with these antigens. Importantly, responses to a superantigen were normal in SLE patients. Compared with healthy controls, SLE patients had fewer EBV-specific T-cells but higher titres of antibodies against EBV. Furthermore, an inverse correlation was revealed between the number of lytic antigen EBV-specific T-cells and disease activity of the SLE patients, with high-activity SLE patients having fewer T-cells than low-activity SLE patients. Conclusions These results indicate a limited or a defective EBV-specific T-cell response in SLE patients, which may suggest poor control of EBV infection in SLE with an immune reaction shift towards a humoral response in an attempt to control viral reactivation. A role for decreased control of EBV as a contributing agent in the development or exacerbation of SLE is proposed. PMID:25396062

  4. Acute HIV Discovered During Routine HIV Screening With HIV Antigen-Antibody Combination Tests in 9 US Emergency Departments.

    Science.gov (United States)

    White, Douglas A E; Giordano, Thomas P; Pasalar, Siavash; Jacobson, Kathleen R; Glick, Nancy R; Sha, Beverly E; Mammen, Priya E; Hunt, Bijou R; Todorovic, Tamara; Moreno-Walton, Lisa; Adomolga, Vincent; Feaster, Daniel J; Branson, Bernard M

    2018-01-05

    Newer combination HIV antigen-antibody tests allow detection of HIV sooner after infection than previous antibody-only immunoassays because, in addition to HIV-1 and -2 antibodies, they detect the HIV-1 p24 antigen, which appears before antibodies develop. We determine the yield of screening with HIV antigen-antibody tests and clinical presentations for new diagnoses of acute and established HIV infection across US emergency departments (EDs). This was a retrospective study of 9 EDs in 6 cities with HIV screening programs that integrated laboratory-based antigen-antibody tests between November 1, 2012, and December 31, 2015. Unique patients with newly diagnosed HIV infection were identified and classified as having either acute HIV infection or established HIV infection. Acute HIV infection was defined as a repeatedly reactive antigen-antibody test result, a negative HIV-1/HIV-2 antibody differentiation assay, or Western blot result, but detectable HIV ribonucleic acid (RNA); established HIV infection was defined as a repeatedly reactive antigen-antibody test result and a positive HIV-1/HIV-2 antibody differentiation assay or Western blot result. The primary outcomes were the number of new HIV diagnoses and proportion of patients with laboratory-defined acute HIV infection. Secondary outcomes compared reason for visit and the clinical presentation of acute HIV infection. In total, 214,524 patients were screened for HIV and 839 (0.4%) received a new diagnosis, of which 122 (14.5%) were acute HIV infection and 717 (85.5%) were established HIV infection. Compared with patients with established HIV infection, those with acute HIV infection were younger, had higher RNA and CD4 counts, and were more likely to have viral syndrome (41.8% versus 6.5%) or fever (14.3% versus 3.4%) as their reason for visit. Most patients with acute HIV infection displayed symptoms attributable to acute infection (median symptom count 5 [interquartile range 3 to 6]), with fever often

  5. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    International Nuclear Information System (INIS)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo

    2014-01-01

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The 3 H and 125 I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step

  6. Performance of scintillation proximity assay (SPA) to measure the level of VEGFR 1 protein

    Energy Technology Data Exchange (ETDEWEB)

    LEE, So-Young; LIM, Jae-Cheong; KIM, Jin-Joo [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2014-10-15

    Scintillation proximity assay is a one of radioimmunoassay and can be assayed without the washing or filtration procedures normally used to separate bound from free fractions. Due to its simplicity and high-throughput protocol, it is broadly applicable to immunology, receptor binding, monitoring receptor-ligand interactions and enzyme reactions. Briefly, an antibody or receptor is coated on SPA beads. When a radiolabeled antigen or ligand binds to the beads, the SPA beads stimulate to emit short range electrons. The {sup 3}H and {sup 125}I are commonly used for radiolabeling and the produced photons are detectable with a liquid scintillation counter (LSC). A binding affinity of unlabeled ligands can be determined by competitive reaction of the radiolabeled ligands. Bevacizumab is a recombinant humanized monoclonal antibody, and can stop or delay growth of tumors by inhibiting vascular endothelial growth factor (VEGF). Bevacizumab was approved by FDA for metastatic cancer such as colorectal cancers, ovarian cancers, breast cancers and glioblastoma multiform of the brain. Recently, Dan G. duda et al. was reported that the concentration of vascular endothelial growth factor receptor-1 (VEGFR-1) in plasma may potentially be used as a negative selection biomarker. In this study, we describe a method using scintillation proximity assay to detect the amounts of VEGFR-1 protein. This method is successfully used to measure the concentration of VEGFR-1 protein in human cell extracts. In summary, a simple and sensitive assay is developed for measuring the amount of VEGFR 1 protein in cancer cell lysate using SPA beads. The antibody coating on the beads and antigen binding are achieved in one mixing step.

  7. Detection and Characterization of Autoantibodies to Neuronal Cell-Surface Antigens in the Central Nervous System

    Directory of Open Access Journals (Sweden)

    Marleen eVan Coevorden-Hameete

    2016-05-01

    Full Text Available Autoimmune encephalitis (AIE is a group of disorders in which autoantibodies directed at antigens located on the plasma membrane of neurons induce severe neurological symptoms. In contrast to classical paraneoplastic disorders, AIE patients respond well to immunotherapy. The detection of neuronal surface autoantibodies in patients’ serum or CSF therefore has serious consequences for the patients’ treatment and follow-up and requires the availability of sensitive and specific diagnostic tests. This mini-review provides a guideline for both diagnostic and research laboratories that work on the detection of known surface autoantibodies and/or the identification of novel surface antigens. We discuss the strengths and pitfalls of different techniques for anti-neuronal antibody detection: 1 Immunohistochemistry and immunofluorescence on rat/ primate brain sections, 2 Immunocytochemistry of living cultured hippocampal neurons, 3 Cell Based Assay (CBA. In addition, we discuss the use of immunoprecipitation and mass spectrometry analysis for the detection of novel neuronal surface antigens, which is a crucial step in further disease classification and the development of novel CBAs.

  8. Evaluation of whole blood IFNgamma test using PPD and recombinant antigen challenge for diagnosis of pulmonary and extra-pulmonary tuberculosis.

    Science.gov (United States)

    Kalantri, Yatiraj; Hemvani, Nanda; Chitnis, D S

    2009-06-01

    Quantiferon TB gold (QFT-G) with recombinant antigen cocktail is well evaluated for diagnosis of pulmonary tuberculosis (PTB). However, diagnosis of extra-pulmonary tuberculosis (EPTB) is more difficult due to limitations of conventional techniques. This study compares recombinant antigens based QFT-G and low cost PPD based interferon test for the diagnosis of PTB and EPTB. IFNgamma release, with recombinant antigens and PPD, was assayed by ELISA from 140 cases of EPTB, 100 cases of PTB along with acid fast bacillus (AFB) detection, AFB culture on LJ and MGIT BACTEC. Sensitivity and specificity for QFT-G recombinant antigens was 84.29% and 96%, while for PPD based interferon was 70% and 84% for EPTB group. The sensitivity was far superior to AFB smear and culture for both the antigens. Nine samples were identified as non-tubercular mycobacteria (NTM) in the EPTB group and all were negative for QFT-G, but six of them were positive for PPD based test. Results of the study show that QFT-G using recombinant antigen is sensitive and specific for both PTB and EPTB diagnosis. The PPD based test is economic and offers comparable performance for PTB and EPTB diagnosis and also useful for diagnosis of NTM.

  9. Autoantibodies and their antigens in autoimmune hepatitis.

    Science.gov (United States)

    Bogdanos, Dimitrios P; Mieli-Vergani, Giorgina; Vergani, Diego

    2009-08-01

    Autoantibody detection assists in the diagnosis and allows differentiation of autoimmune hepatitis (AIH) type 1 (AIH-1), characterized by antinuclear antibody (ANA) and/or smooth muscle antibody (SMA), and type 2 (AIH-2), distinguished by the presence of antibodies to liver-kidney microsome type 1 (anti-LKM1) and/or antibodies to liver cytosol type 1 (anti-LC1). Detection of atypical perinuclear antineutrophil cytoplasmic antibodies (pANCA) and anti-soluble liver antigen (SLA) antibodies can act as an additional pointer toward the diagnosis of AIH, particularly in the absence of the conventional autoantibodies. Routine autoantibody testing by indirect immunofluorescence has been recently complemented by molecular assays based on purified or recombinant antigens. Although the AIH-1-specific ANA and SMA targets need better definition, those of anti-LKM1 and anti-LC1 in AIH-2 have been clearly identified; the fine specificity of antibody reactivity and its clinical relevance to disease pathogenesis are the focus of ongoing investigation. This article critically discusses the current knowledge of the diagnostic and clinical significance of AIH-related autoantibody reactivities, focusing on key issues that the physician needs to be aware of to be able to request the appropriate testing and to interpret correctly the laboratory results within the clinical context of the patient. Copyright Thieme Medical Publishers.

  10. The normal chain length distribution of the O antigen is required for the interaction of Shigella flexneri 2a with polarized Caco-2 cells

    Directory of Open Access Journals (Sweden)

    Anilei Hoare

    2012-01-01

    Full Text Available Shigella flexneri causes bacillary dysentery in humans. Essential to the establishment of the disease is the invasion of the colonic epithelial cells. Here we investigated the role of the lipopolysaccharide (LPS O antigen in the ability of S. flexneri to adhere to and invade polarized Caco-2 cells. The S. flexneri 2a O antigen has two preferred chain lengths: a short O antigen (S-OAg regulated by the WzzB protein and a very long O antigen (VL-OAg regulated by Wzz pHS2. Mutants with defined deletions of the genes required for O-antigen assembly and polymerization were constructed and assayed for their abilities to adhere to and enter cultured epithelial cells. The results show that both VL- and S-OAg are required for invasion through the basolateral cell membrane. In contrast, the absence of O antigen does not impair adhesion. Purified LPS does not act as a competitor for the invasion of Caco-2 cells by the wild-type strain, suggesting that LPS is not directly involved in the internalization process by epithelial cells.

  11. A real-time loop-mediated isothermal amplification assay for rapid detection of Shigella species.

    Science.gov (United States)

    Liew, P S; Teh, C S J; Lau, Y L; Thong, K L

    2014-12-01

    Shigellosis is a foodborne illness caused by the genus Shigella and is an important global health issue. The development of effective techniques for rapid detection of this pathogen is essential for breaking the chain of transmission. Therefore, we have developed a novel loop-mediated isothermal amplification (LAMP) assay targeting the invasion plasmid antigen H (ipaH) gene to rapidly detect Shigella species. This assay could be performed in 90 min at an optimal temperature of 64ºC, with endpoint results visualized directly. Notably, the method was found to be more sensitive than conventional PCR. Indeed, the detection limit for the LAMP assay on pure bacterial cultures was 5.9 x 10(5) CFU/ml, while PCR displayed a limit of 5.9 x 10(7) CFU/ml. In spiked lettuce samples, the sensitivity of the LAMP assay was 3.6 x 10(4) CFU/g, whereas PCR was 3.6 x 10(5) CFU/g. Overall, the assay accurately identified 32 Shigella spp. with one enteroinvasive Escherichia coli displaying positive reaction while the remaining 32 non-Shigella strains tested were negative.

  12. Immunizing Patients With Metastatic Melanoma Using Recombinant Adenoviruses Encoding MART-1 or gp100 Melanoma Antigens

    Science.gov (United States)

    Rosenberg, Steven A.; Zhai, Yifan; Yang, James C.; Schwartzentruber, Douglas J.; Hwu, Patrick; Marincola, Francesco M.; Topalian, Suzanne L.; Restifo, Nicholas P.; Seipp, Claudia A.; Einhorn, Jan H.; Roberts, Bruce; White, Donald E.

    2008-01-01

    Background: The characterization of the genes encoding melanoma-associated antigens MART-1 or gp100, recognized by T cells, has opened new possibilities for the development of immunization strategies for patients with metastatic melanoma. With the use of recombinant adenoviruses expressing either MART-1 or gp100 to immunize patients with metastatic melanoma, we evaluated the safety, immunologic, and potential therapeutic aspects of these immunizations. Methods: In phase I studies, 54 patients received escalating doses (between 107 and 1011 plaque-forming units) of recombinant adenovirus encoding either MART-1 or gp100 melanoma antigen administered either alone or followed by the administration of interleukin 2 (IL-2). The immunologic impact of these immunizations on the development of cellular and antibody reactivity was assayed. Results: Recombinant adenoviruses expressing MART-1 or gp100 were safely administered. One of 16 patients with metastatic melanoma receiving the recombinant adenovirus MART-1 alone experienced a complete response. Other patients achieved objective responses, but they had received IL-2 along with an adenovirus, and their responses could be attributed to the cytokine. Immunologic assays showed no consistent immunization to the MART-1 or gp100 transgenes expressed by the recombinant adenoviruses. High levels of neutralizing antibody were found in the pretreatment sera of the patients. Conclusions: High doses of recombinant adenoviruses could be safely administered to cancer patients. High levels of neutralizing antibody present in patients' sera prior to treatment may have impaired the ability of these viruses to immunize patients against melanoma antigens. PMID:9862627

  13. Clostridium difficile 027/BI/NAP1 encodes a hypertoxic and antigenically variable form of TcdB.

    Directory of Open Access Journals (Sweden)

    Jordi M Lanis

    Full Text Available The Clostridium difficile exotoxin, TcdB, which is a major virulence factor, varies between strains of this pathogen. Herein, we show that TcdB from the epidemic BI/NAP1/027 strain of C. difficile is more lethal, causes more extensive brain hemorrhage, and is antigenically variable from TcdB produced by previously studied strains of this pathogen (TcdB003. In mouse intoxication assays, TcdB from a ribotype 027 strain (TcdB027 was at least four fold more lethal than TcdB003. TcdB027 caused a previously undescribed brain hemorrhage in mice and this correlated with a heightened sensitivity of brain microvascular endothelial cells to the toxin. TcdB003 and TcdB027 also differed in their antigenic profiles and did not share cross-neutralizing epitopes in a major immunogenic region of the protein. Solid phase humoral mapping of epitopes in the carboxy-terminal domains (CTD of TcdB027 and TcdB003 identified 11 reactive epitopes that varied between the two forms of TcdB, and 13 epitopes that were shared or overlapping. Despite the epitope differences and absence of neutralizing epitopes in the CTD of TcdB027, a toxoid form of this toxin primed a strong protective response. These findings indicate TcdB027 is a more potent toxin than TcdB003 as measured by lethality assays and pathology, moreover the sequence differences between the two forms of TcdB alter antigenic epitopes and reduce cross-neutralization by antibodies targeting the CTD.

  14. A yeast-based assay identifies drugs that interfere with immune evasion of the Epstein-Barr virus

    Directory of Open Access Journals (Sweden)

    Cécile Voisset

    2014-04-01

    Full Text Available Epstein-Barr virus (EBV is tightly associated with certain human cancers, but there is as yet no specific treatment against EBV-related diseases. The EBV-encoded EBNA1 protein is essential to maintain viral episomes and for viral persistence. As such, EBNA1 is expressed in all EBV-infected cells, and is highly antigenic. All infected individuals, including individuals with cancer, have CD8+ T cells directed towards EBNA1 epitopes, yet the immune system fails to detect and destroy cells harboring the virus. EBV immune evasion depends on the capacity of the Gly-Ala repeat (GAr domain of EBNA1 to inhibit the translation of its own mRNA in cis, thereby limiting the production of EBNA1-derived antigenic peptides presented by the major histocompatibility complex (MHC class I pathway. Here we establish a yeast-based assay for monitoring GAr-dependent inhibition of translation. Using this assay we identify doxorubicin (DXR as a compound that specifically interferes with the GAr effect on translation in yeast. DXR targets the topoisomerase-II–DNA complexes and thereby causes genomic damage. We show, however, that the genotoxic effect of DXR and various analogs thereof is uncoupled from the effect on GAr-mediated translation control. This is further supported by the observation that etoposide and teniposide, representing another class of topoisomerase-II–DNA targeting drugs, have no effect on GAr-mediated translation control. DXR and active analogs stimulate, in a GAr-dependent manner, EBNA1 expression in mammalian cells and overcome GAr-dependent restriction of MHC class I antigen presentation. These results validate our approach as an effective high-throughput screening assay to identify drugs that interfere with EBV immune evasion and, thus, constitute candidates for treating EBV-related diseases, in particular EBV-associated cancers.

  15. A yeast-based assay identifies drugs that interfere with immune evasion of the Epstein-Barr virus.

    Science.gov (United States)

    Voisset, Cécile; Daskalogianni, Chrysoula; Contesse, Marie-Astrid; Mazars, Anne; Arbach, Hratch; Le Cann, Marie; Soubigou, Flavie; Apcher, Sébastien; Fåhraeus, Robin; Blondel, Marc

    2014-04-01

    Epstein-Barr virus (EBV) is tightly associated with certain human cancers, but there is as yet no specific treatment against EBV-related diseases. The EBV-encoded EBNA1 protein is essential to maintain viral episomes and for viral persistence. As such, EBNA1 is expressed in all EBV-infected cells, and is highly antigenic. All infected individuals, including individuals with cancer, have CD8(+) T cells directed towards EBNA1 epitopes, yet the immune system fails to detect and destroy cells harboring the virus. EBV immune evasion depends on the capacity of the Gly-Ala repeat (GAr) domain of EBNA1 to inhibit the translation of its own mRNA in cis, thereby limiting the production of EBNA1-derived antigenic peptides presented by the major histocompatibility complex (MHC) class I pathway. Here we establish a yeast-based assay for monitoring GAr-dependent inhibition of translation. Using this assay we identify doxorubicin (DXR) as a compound that specifically interferes with the GAr effect on translation in yeast. DXR targets the topoisomerase-II-DNA complexes and thereby causes genomic damage. We show, however, that the genotoxic effect of DXR and various analogs thereof is uncoupled from the effect on GAr-mediated translation control. This is further supported by the observation that etoposide and teniposide, representing another class of topoisomerase-II-DNA targeting drugs, have no effect on GAr-mediated translation control. DXR and active analogs stimulate, in a GAr-dependent manner, EBNA1 expression in mammalian cells and overcome GAr-dependent restriction of MHC class I antigen presentation. These results validate our approach as an effective high-throughput screening assay to identify drugs that interfere with EBV immune evasion and, thus, constitute candidates for treating EBV-related diseases, in particular EBV-associated cancers.

  16. Antigen presentation and MHC class II expression by human esophageal epithelial cells: role in eosinophilic esophagitis.

    Science.gov (United States)

    Mulder, Daniel J; Pooni, Aman; Mak, Nanette; Hurlbut, David J; Basta, Sameh; Justinich, Christopher J

    2011-02-01

    Professional antigen-presenting cells (APCs) play a crucial role in initiating immune responses. Under pathological conditions, epithelial cells at mucosal surfaces act as nonprofessional APCs, thereby regulating immune responses at the site of exposure. Epithelial cells in the esophagus may contribute to the pathogenesis of eosinophilic esophagitis (EoE) by presenting antigens on the major histocompatibility complex (MHC) class II. Our goal was to demonstrate the ability of esophageal epithelial cells to process and present antigens on the MHC class II system and to investigate the contribution of epithelial cell antigen presentation to EoE. Immunohistochemistry detected HLA-DR, CD80, and CD86 expression and enzyme-linked immunosorbent assay detected interferon-γ (IFNγ) in esophageal biopsies. Antigen presentation was studied using the human esophageal epithelial cell line HET-1A by reverse transcriptase-PCR, flow cytometry, and confocal microscopy. T helper cell lymphocyte proliferation was assessed by flow cytometry and IL-2 secretion. IFNγ and MHC class II were increased in mucosa of patients with EoE. IFNγ increased mRNA of HLA-DP, HLA-DQ, HLA-DR, and CIITA in HET-1A cells. HET-1A engulfed cell debris and processed ovalbumin. HET-1A cells expressed HLA-DR after IFNγ treatment. HET-1A stimulated T helper cell activation. In this study, we demonstrated the ability of esophageal epithelial cells to act as nonprofessional APCs in the presence of IFNγ. Esophageal epithelial cell antigen presentation may contribute to the pathophysiology of eosinophilic esophagitis. Copyright © 2011 American Society for Investigative Pathology. Published by Elsevier Inc. All rights reserved.

  17. Usefulness of serological ELISA assay forTaenia saginata to detect naturally infected bovines

    Directory of Open Access Journals (Sweden)

    Silvana de Cássia Paulan

    Full Text Available Bovine cysticercosis, a cosmopolitan disease caused by Taenia saginata, leads to economic losses due to carcass devaluation at slaughter. Sanitary inspection at slaughterhouses, the routine diagnostic method in Brazil, lacks the necessary sensitivity to detect the mildly infected cattle that are typically encoutered in Brazil. In this study we have tested cattle sera from animals diagnosed as positive and negative by veterianry inspection for (1 anti-parasite antibodies using metacestodes antigens (T. solium vesicular fluid and T. saginata secretions and (2 the HP10 secreted antigen of viable metacestodes. The cut-off values were calculated by ROC curve for intense and mild infections conditions, and by the classical method ( for negative samples. The sensitivity and specificity of these diagnostic tests were different depending on the assumed cut-off value and, importantly, whether the infection was mild or intense. In spite of these observations, however, such ELISA assays for serum antibodies and parasite antigens constitute an important tool for epidemiological porposes, and in establishing priorities for the control of bovine cysticercosis.

  18. The influence of hapten density on the assay of penicilloylated proteins in fluids

    International Nuclear Information System (INIS)

    Lee, D.; Dewdney, J.M.; Edwards, R.G.

    1985-01-01

    The use of inhibition radioimmunoassays for the measurement of penicilloylated proteins in biological fluids is compromised by the dominant influence of hapten density. Precise quantitation, and therefore assessment of antigenicity and immunogenicity, cannot be achieved in the absence of knowledge of the number and distribution of haptenic groups on the protein carrier. These assays may not, therefore, be appropriate for the measurement of potential allergenic residues in food products. (Auth.)

  19. Development of a serology-based assay for efficacy evaluation of a lactococcicosis vaccine in Seriola fish.

    Science.gov (United States)

    Nakajima, Nao; Kawanishi, Michiko; Imamura, Saiki; Hirano, Fumiya; Uchiyama, Mariko; Yamamoto, Kinya; Nagai, Hidetaka; Futami, Kunihiko; Katagiri, Takayuki; Maita, Masashi; Kijima, Mayumi

    2014-05-01

    Lactococcicosis is an infection caused by the bacterium Lactococcus garvieae and creates serious economic damage to cultured marine and fresh water fish industries. The use of the assay currently applied to evaluate the potency of the lactococcicosis vaccine is contingent upon meeting specific parameters after statistical analysis of the percent survival of the vaccinated yellowtail or greater amberjack fish after challenge with a virulent strain of L. garvieae. We found that measuring the serological response with a quantitative agglutinating antibody against the L. garvieae antigen (phenotype KG+) was an effective method of monitoring the potency of lactococcicosis vaccines. Vaccinated fish had significantly higher antibody titers than control fish when the L. garvieae Lg2-S strain was used as an antigen. Furthermore, the titer of the KG + agglutinating antibody was correlated with vaccine potency, and the cut-off titer was determined by comparing the data with those from the challenge test. An advantage of the proposed serology-based potency assay is that it will contribute to reduced numbers of animal deaths during vaccine potency evaluations. Copyright © 2014 Elsevier Ltd. All rights reserved.

  20. Application of recombinant antigen 5 allergens from seven allergy-relevant Hymenoptera species in diagnostics.

    Science.gov (United States)

    Schiener, M; Eberlein, B; Moreno-Aguilar, C; Pietsch, G; Serrano, P; McIntyre, M; Schwarze, L; Russkamp, D; Biedermann, T; Spillner, E; Darsow, U; Ollert, M; Schmidt-Weber, C B; Blank, S

    2017-01-01

    Hymenoptera stings can cause severe anaphylaxis in untreated venom-allergic patients. A correct diagnosis regarding the relevant species for immunotherapy is often hampered by clinically irrelevant cross-reactivity. In vespid venom allergy, cross-reactivity between venoms of different species can be a diagnostic challenge. To address immunological IgE cross-reactivity on molecular level, seven recombinant antigens 5 of the most important Vespoidea groups were assessed by different diagnostic setups. The antigens 5 of yellow jackets, hornets, European and American paper wasps, fire ants, white-faced hornets, and Polybia wasps were recombinantly produced in insect cells, immunologically and structurally characterized, and their sIgE reactivity assessed by ImmunoCAP, ELISA, cross-inhibition, and basophil activation test (BAT) in patients with yellow jacket or Polistes venom allergy of two European geographical areas. All recombinant allergens were correctly folded and structural models and patient reactivity profiles suggested the presence of conserved and unique B-cell epitopes. All antigens 5 showed extensive cross-reactivity in sIgE analyses, inhibition assays, and BAT. This cross-reactivity was more pronounced in ImmunoCAP measurements with venom extracts than in sIgE analyses with recombinant antigens 5. Dose-response curves with the allergens in BAT allowed a differentiated individual dissection of relevant sensitization. Due to extensive cross-reactivity in various diagnostic settings, antigens 5 are inappropriate markers for differential sIgE diagnostics in vespid venom allergy. However, the newly available antigens 5 from further vespid species and the combination of recombinant allergen-based sIgE measurements with BAT represents a practicable way to diagnose clinically relevant sensitization in vespid venom allergy. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.