WorldWideScience

Sample records for vascular impedance measurement

  1. Pulmonary Vascular Input Impedance is a Combined Measure of Pulmonary Vascular Resistance and Stiffness and Predicts Clinical Outcomes Better than PVR Alone in Pediatric Patients with Pulmonary Hypertension

    Science.gov (United States)

    Hunter, Kendall S.; Lee, Po-Feng; Lanning, Craig J.; Ivy, D. Dunbar; Kirby, K. Scott; Claussen, Lori R.; Chan, K. Chen; Shandas, Robin

    2011-01-01

    Background Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated an method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero-harmonic impedance value and PVR, and suggested a correlation between higher harmonic impedance values and pulmonary vascular stiffness (PVS). Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and PVS from a single measurement, and that impedance is a better predictor of disease outcomes compared to PVR. Methods Pressure and velocity waveforms within the main PA were measured during right-heart catheterization of patients with normal PA hemodynamics (n=14) and those with PAH undergoing reactivity evaluation (49 subjects; 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Results Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y=1.095·x+1.381, R2=0.9620). Additionally, the modulus sum of the first two harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (PP/SV) (y=13.39·x-0.8058, R2=0.7962). Amongst a subset of PAH patients (n=25), cumulative logistic regression between outcomes to total indexed impedance was better (RL2=0.4012) than between outcomes and indexed PVR (RL2=0.3131). Conclusions Input impedance can be consistently and easily obtained from PW Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and better predicts patient

  2. Pulmonary vascular input impedance is a combined measure of pulmonary vascular resistance and stiffness and predicts clinical outcomes better than pulmonary vascular resistance alone in pediatric patients with pulmonary hypertension.

    Science.gov (United States)

    Hunter, Kendall S; Lee, Po-Feng; Lanning, Craig J; Ivy, D Dunbar; Kirby, K Scott; Claussen, Lori R; Chan, K Chen; Shandas, Robin

    2008-01-01

    Pulmonary vascular resistance (PVR) is the current standard for evaluating reactivity in children with pulmonary arterial hypertension (PAH). However, PVR measures only the mean component of right ventricular afterload and neglects pulsatile effects. We recently developed and validated a method to measure pulmonary vascular input impedance, which revealed excellent correlation between the zero harmonic impedance value and PVR and suggested a correlation between higher-harmonic impedance values and pulmonary vascular stiffness. Here we show that input impedance can be measured routinely and easily in the catheterization laboratory, that impedance provides PVR and pulmonary vascular stiffness from a single measurement, and that impedance is a better predictor of disease outcomes compared with PVR. Pressure and velocity waveforms within the main pulmonary artery were measured during right heart catheterization of patients with normal pulmonary artery hemodynamics (n = 14) and those with PAH undergoing reactivity evaluation (49 subjects, 95 conditions). A correction factor needed to transform velocity into flow was obtained by calibrating against cardiac output. Input impedance was obtained off-line by dividing Fourier-transformed pressure and flow waveforms. Exceptional correlation was found between the indexed zero harmonic of impedance and indexed PVR (y = 1.095x + 1.381, R2 = 0.9620). In addition, the modulus sum of the first 2 harmonics of impedance was found to best correlate with indexed pulse pressure over stroke volume (y = 13.39x - 0.8058, R2 = 0.7962). Among a subset of patients with PAH (n = 25), cumulative logistic regression between outcomes to total indexed impedance was better (R(L)2 = 0.4012) than between outcomes and indexed PVR (R(L)2 = 0.3131). Input impedance can be consistently and easily obtained from pulse-wave Doppler and a single catheter pressure measurement, provides comprehensive characterization of the main components of RV afterload, and

  3. RF impedance measurement calibration

    International Nuclear Information System (INIS)

    Matthews, P.J.; Song, J.J.

    1993-01-01

    The intent of this note is not to explain all of the available calibration methods in detail. Instead, we will focus on the calibration methods of interest for RF impedance coupling measurements and attempt to explain: (1). The standards and measurements necessary for the various calibration techniques. (2). The advantages and disadvantages of each technique. (3). The mathematical manipulations that need to be applied to the measured standards and devices. (4). An outline of the steps needed for writing a calibration routine that operated from a remote computer. For further details of the various techniques presented in this note, the reader should consult the references

  4. Microwave Impedance Measurement for Nanoelectronics

    Directory of Open Access Journals (Sweden)

    M. Randus

    2011-04-01

    Full Text Available The rapid progress in nanoelectronics showed an urgent need for microwave measurement of impedances extremely different from the 50Ω reference impedance of measurement instruments. In commonly used methods input impedance or admittance of a device under test (DUT is derived from measured value of its reflection coefficient causing serious accuracy problems for very high and very low impedances due to insufficient sensitivity of the reflection coefficient to impedance of the DUT. This paper brings theoretical description and experimental verification of a method developed especially for measurement of extreme impedances. The method can significantly improve measurement sensitivity and reduce errors caused by the VNA. It is based on subtraction (or addition of a reference reflection coefficient and the reflection coefficient of the DUT by a passive network, amplifying the resulting signal by an amplifier and measuring the amplified signal as a transmission coefficient by a common vector network analyzer (VNA. A suitable calibration technique is also presented.

  5. Short-circuit impedance measurement

    DEFF Research Database (Denmark)

    Pedersen, Knud Ole Helgesen; Nielsen, Arne Hejde; Poulsen, Niels Kjølstad

    2003-01-01

    Methods for estimating the short-circuit impedance in the power grid are investigated for various voltage levels and situations. The short-circuit impedance is measured, preferably from naturally occurring load changes in the grid, and it is shown that such a measurement system faces different...

  6. Acoustic impedances of ear canals measured by impedance tube

    DEFF Research Database (Denmark)

    Ciric, Dejan; Hammershøi, Dorte

    2007-01-01

    During hearing sensitivity tests, the sound field is commonly generated by an earphone placed on a subject ear. One of the factors that can affect the sound transmission in the ear is the acoustic impedance of the ear canal. Its importance is related to the contribution of other elements involved...... in the transmission such as the earphone impedance. In order to determine the acoustic impedances of human ear canals, the standardized method for measurement of complex impedances used for the measurement of the audiometric earphone impedances is applied. It is based on the transfer function between two microphone...... locations in an impedance tube. The end of the tube representing the measurement plane is placed at the ear canal entrance. Thus, the impedance seen from the entrance inward is measured on 25 subjects. Most subjects participated in the previous measurement of the ratio between the pressures at the open...

  7. MVAC Submarine cable, impedance measurements and analysis

    DEFF Research Database (Denmark)

    Arentsen, Martin Trolle; Expethit, Adrian; Pedersen, Morten Virklund

    2017-01-01

    influence the losses. Secondly, cable parameters such as component impedances, positive-, zero-sequence impedances and losses are measured for varying currents and frequencies. Zero sequence is measured for two setups, one with armour grounded, and with armour open to match CIGREs formula assumption......-sequence impedance is found between the measurements and the CIGRÉ formulas. It is concluded that the formulas are not accurate for the specific cable under test....

  8. Quantification of coating aging using impedance measurements

    NARCIS (Netherlands)

    Westing, E.P.M. van; Weijde, D.H. van der; Vreijling, M.P.W.; Ferrari, G.M.; Wit, J.H.W. de

    1998-01-01

    This chapter shows the application results of a novel approach to quantify the ageing of organic coatings using impedance measurements. The ageing quantification is based on the typical impedance behaviour of barrier coatings in immersion. This immersion behaviour is used to determine the limiting

  9. Electrical Impedance Measurements of PZT Nanofiber Sensors

    Directory of Open Access Journals (Sweden)

    Richard Galos

    2017-01-01

    Full Text Available Electrical impedance measurements of PZT nanofiber sensors were performed using a variety of methods over a frequency spectrum ranging from DC to 1.8 GHz. The nanofibers formed by electrospinning with diameters ranging from 10 to 150 nm were collected and integrated into sensors using microfabrication techniques. Special matching circuits with ultrahigh input impedance were fabricated to produce low noise, measurable sensor outputs. Material properties including resistivity and dielectric constant are derived from the impedance measurements. The resulting material properties are also compared with those of individual nanofibers being tested using conductive AFM and Scanning Conductive Microscopy.

  10. Impedance measurements of components for the ALS

    International Nuclear Information System (INIS)

    Corlett, J.N.; Rimmer, R.A.

    1993-05-01

    The high current and short bunch length of the ALS beam make the machine susceptible to beam instabilities over a frequency range extending to 13 GHz and beyond. All components of the storage ring have been carefully designed to minimize the impedance presented to the beam, and assemblies have been laid out to avoid resonant enclosures between components. Novel bellows shields allowing considerable mechanical movement while maintaining a low impedance are described. Results are presented of impedance measurements of ALS components and assemblies of components, using a precision coaxial wire technique in frequency domain, extending to frequencies beyond cut-off. All measurements were performed at the Lambertson Beam Electrodynamics Laboratory of the Center for Beam Physics at LBL

  11. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Hofmann, A.; Jowett, J.; Lockman, W.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.

    1988-05-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. The results showed that, although the gross longitudinal impedance had indeed been reduced, the 'capacitive' component had also decreased relative to the 'inductive'--to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded 'capacitor' cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained. 7 refs., 6 figs

  12. Bunch length and impedance measurements in SPEAR

    International Nuclear Information System (INIS)

    Bane, K.; Donald, M.; Morton, P.; Stege, R.; Spence, W.; Wilson, P.; Hofmann, A.; Jowett, J.; Lockman, W.

    1988-01-01

    Subsequent to an extensive smoothing of the vacuum chamber a comprehensive study of the SPEAR impedance was undertaken. Bunch length, synchrotron quadrupole mode frequency, and parasitic mode loss were measured as functions of beam current. This paper shows that although the gross longitudinal impedance had indeed been reduced, the capacitive component had also decreased relative to the inductive - to the extent that previously compensated potential well distortion now induced bunch lengthening at low currents, and the turbulent threshold had actually been lowered. A specially designed multi-cell disc-loaded capacitor cavity was shown to be capable of removing this effect by restoring the original compensation. A model of the new SPEAR impedance is also obtained

  13. Detection of irradiated potatoes by impedance measurement

    International Nuclear Information System (INIS)

    Hayashi, T.; Todoriki, S.; Otobe, K.; Sugiyama, J.

    1996-01-01

    Potato is one of the major food items to be treated with ionising radiation and potatoes are irradiated on a large scale in several countries. Every year around 15,000 t of potatoes are irradiated at doses of 60 to 150 Gy (average dose is about 100 Gy) in Japan. Although various methods to detect irradiated potatoes have been investigated, no established method has been reported. Measuring electrical conductivity or impedance of potatoes has been reported as a promising method for the detection of irradiated potatoes. In previous studies it has been found that the ratio of impedance magnitude at 50 kHz to that at 5 kHz, measured immediately after puncturing a potato tuber, is dependent upon the dose applied to the tuber, independent of storage temperature and stable during storage after irradiation. The aim of this study was to establish the optimum conditions for impedance measurement and to examine the applicability of the impedance measuring method to various cultivars (cv.) of potatoes. (author)

  14. Beam measurements of the SPS longitudinal impedance

    CERN Document Server

    Lasheen, A

    2017-01-01

    Longitudinal instabilities are one of the main limitationsin the CERN SPS to reach the beam parameters requiredfor the High Luminosity LHC project. In preparation tothe SPS upgrade, possible remedies are studied by perform-ing macroparticle simulations using the machine impedancemodel obtained from electromagnetic simulations and mea-surements. To benchmark the impedance model, the resultsof simulations are compared with various beam measure-ments. In this study, the reactive part of the impedance wasprobed by measuring the quadrupole frequency shift withintensity, obtained from bunch length oscillations at mis-matched injection into the SPS. This method was appliedover many last years to follow up the evolution of the SPSimpedance, injecting bunches with the same bunch length.A novel approach, giving significantly more information,consists in varying the injected bunch length. The compari-son of these measurements with macroparticle simulationsallowed to test the existing model and identify some missingSPS i...

  15. Video rate electrical impedance tomography of vascular changes: preclinical development

    International Nuclear Information System (INIS)

    Halter, Ryan; Hartov, Alex; Paulsen, Keith

    2008-01-01

    Peripheral vasculature disease is strongly correlated with cardiovascular-associated mortality. Monitoring circulation health, especially in the peripheral limbs, is vital to detecting clinically significant disease at a stage when it can still be addressed through medical intervention. Electrical impedance tomography (EIT) maps the electrical properties of tissues within the body and has been used to image dynamically varying physiology, including blood flow. Here, we suggest that peripheral vasculature health can be monitored with EIT by imaging the hemodynamics of peripheral vessels and the surrounding tissues during reactive hyperemia testing. An analysis based on distinguishability theory is presented that indicates that an EIT system capable of making measurements with a precision of 50 µV may be able to detect small changes in vessel size associated with variations in blood flow. An EIT system with these precision capabilities is presented that is able to collect data at frame rates exceeding 30 fps over a broad frequency range up to 10 MHz. The system's high speed imaging performance is verified through high contrast phantom experiments and through physiological imaging of induced ischemia with a human forearm. Region of interest analysis of the induced ischemia images shows a marked decrease in conductivity over time, changing at a rate of approximately −3 × 10 −7 S m −1 s −1 , which is the same order of magnitude as reported in the literature. The distinguishability analysis suggests that a system such as the one developed here may provide a means to characterize the hemodynamics associated with blood flow through the peripheral vasculature

  16. Techniques for beam impedance measurements above cutoff

    International Nuclear Information System (INIS)

    Lambertson, G.R.; Jacob, A.F.; Rimmer, R.A.; Voelker, F.

    1990-08-01

    Methods for measuring beam impedance above cutoff have been very limited. For design work on the ALS we have developed two techniques that yield data in the frequency domain with high sensitivity. The first is an extension of the wire method; the second utilizes traveling TM waves to simulate the beam's fields at the wall, and thus avoids the mechanical difficulties of mounting the wire. It is also more sensitive than the other method but the interpretation is complicated by the presence of higher order modes. With either method we were able to detect resonant peaks smaller than 1 Ohm at 10 GHz

  17. Compensating for evanescent modes and estimating characteristic impedance in waveguide acoustic impedance measurements

    DEFF Research Database (Denmark)

    Nørgaard, Kren Rahbek; Fernandez Grande, Efren

    2017-01-01

    The ear-canal acoustic impedance and reflectance are useful for assessing conductive hearing disorders and calibrating stimulus levels in situ. However, such probe-based measurements are affected by errors due to the presence of evanescent modes and incorrect estimates or assumptions regarding...... characteristic impedance. This paper proposes a method to compensate for evanescent modes in measurements of acoustic impedance, reflectance, and sound pressure in waveguides, as well as estimating the characteristic impedance immediately in front of the probe. This is achieved by adjusting the characteristic...... impedance and subtracting an acoustic inertance from the measured impedance such that the non-causality in the reflectance is minimized in the frequency domain using the Hilbert transform. The method is thus capable of estimating plane-wave quantities of the sought-for parameters by supplying only...

  18. Rf Discharge Impedance Measurements Using a New Method to Determine the Stray Impedances

    NARCIS (Netherlands)

    Bakker, L.P.; Kroesen, G.M.W.; Hoog, de F.J.

    1999-01-01

    The impedance of a capacitively coupled radio frequency discharge in a tubular fluorescent lamp filled with neon and mercury is measured. The stray impedances in the electrical network are determined using a new method that requires no extra instruments. The reflection of power is used to determine

  19. Impedance Localization Measurements using AC Dipoles in the LHC

    CERN Document Server

    Biancacci, Nicolo; Papotti, Giulia; Persson, Tobias; Salvant, Benoit; Tomás, Rogelio

    2016-01-01

    The knowledge of the LHC impedance is of primary importance to predict the machine performance and allow for the HL-LHC upgrade. The developed impedance model can be benchmarked with beam measurements in order to assess its validity and limit. This is routinely done, for example, moving the LHC collimator jaws and measuring the induced tune shift. In order to localize possible unknown impedance sources, the variation of phase advance with intensity between beam position monitors can be measured. In this work we will present the impedance localization measurements performed at injection in the LHC using AC dipoles as exciter as well as the underlying theory.

  20. Operators manual for a computer controlled impedance measurement system

    Science.gov (United States)

    Gordon, J.

    1987-02-01

    Operating instructions of a computer controlled impedance measurement system based in Hewlett Packard instrumentation are given. Hardware details, program listings, flowcharts and a practical application are included.

  1. Beam measurements of the LHC impedance and validation of the impedance model

    CERN Document Server

    Esteban Müller, J F; Bohl, T; Mounet, N; Shaposhnikova, E; Timko, H

    2014-01-01

    Different measurements of the longitudinal impedance of the LHC done with single bunches with various intensities and longitudinal emittances during measurement sessions in 2011-2012 are compared with particle simulations based on the existing LHC impedance model. The very low reactive impedance of the LHC, with Im Z=n = 0.08, is not easy to measure. The most sensitive observation is the loss of Landau damping, which shows at which energy bunches become unstable depending on their parameters. In addition, the synchrotron frequency shift due to the reactive impedance was estimated following two methods. Firstly, it was obtained from the peak-detected Schottky spectrum. Secondly, a sine modulation in the RF phase was applied to the bunches of different intensities and the modulation frequency was scanned. In both cases, the synchrotron frequency shift was of the order of the measurement precision.

  2. Transverse impedance measurement in RHIC and the AGS

    Energy Technology Data Exchange (ETDEWEB)

    Biancacci, Nicolo [European Organization for Nuclear Research (CERN), Geneva (Switzerland); Blaskiewicz, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Dutheil, Y. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Liu, C. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Mernick, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; Minty, M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.; White, S. M. [Brookhaven National Lab. (BNL), Upton, NY (United States). Collider-Accelerator Dept.

    2014-05-12

    The RHIC luminosity upgrade program aims for an increase of the polarized proton luminosity by a factor 2. To achieve this goal a significant increase in the beam intensity is foreseen. The beam coupling impedance could therefore represent a source of detrimental effects for beam quality and stability at high bunch intensities. For this reason it is essential to quantify the accelerator impedance budget and the major impedance sources, and possibly cure them. In this MD note we summarize the results of the 2013 transverse impedance measurements in the AGS and RHIC. The studies have been performed measuring the tune shift as a function of bunch intensity and deriving the total accelerator machine transverse impedance. For RHIC, we could obtain first promising results of impedance localization measurements as well.

  3. Measurement errors in multifrequency bioelectrical impedance analyzers with and without impedance electrode mismatch

    International Nuclear Information System (INIS)

    Bogónez-Franco, P; Nescolarde, L; Bragós, R; Rosell-Ferrer, J; Yandiola, I

    2009-01-01

    The purpose of this study is to compare measurement errors in two commercially available multi-frequency bioimpedance analyzers, a Xitron 4000B and an ImpediMed SFB7, including electrode impedance mismatch. The comparison was made using resistive electrical models and in ten human volunteers. We used three different electrical models simulating three different body segments: the right-side, leg and thorax. In the electrical models, we tested the effect of the capacitive coupling of the patient to ground and the skin–electrode impedance mismatch. Results showed that both sets of equipment are optimized for right-side measurements and for moderate skin–electrode impedance mismatch. In right-side measurements with mismatch electrode, 4000B is more accurate than SFB7. When an electrode impedance mismatch was simulated, errors increased in both bioimpedance analyzers and the effect of the mismatch in the voltage detection leads was greater than that in current injection leads. For segments with lower impedance as the leg and thorax, SFB7 is more accurate than 4000B and also shows less dependence on electrode mismatch. In both devices, impedance measurements were not significantly affected (p > 0.05) by the capacitive coupling to ground

  4. Electrochemical impedance measurement of a carbon nanotube probe electrode

    International Nuclear Information System (INIS)

    Inaba, Akira; Takei, Yusuke; Kan, Tetsuo; Shimoyama, Isao; Matsumoto, Kiyoshi

    2012-01-01

    We measured and analyzed the electrochemical impedance of carbon nanotube (CNT) probe electrodes fabricated through the physical separation of insulated CNT bridges. The fabricated CNT electrodes were free-standing CNTs that were completely covered with an insulator, except for their tips. Typical dimensions of the nanoelectrodes were 1–10 nm in CNT diameter, 80–300 nm in insulator diameter, 0.5–4 μm in exposed CNT length and 1–10 μm in probe length. The electrochemical impedance at frequencies ranging from 40 Hz to 1 MHz was measured in physiological saline. The measured impedance of the CNT electrode was constant at 32 MΩ at frequencies below 1 kHz and was inversely proportional to frequency at frequencies above 10 kHz. By means of comparison with the parasitic capacitive impedance of the insulator membrane, we confirmed that the electrode was sufficiently insulated such that the measured constant impedance was given by the exposed CNT tip. Consequently, we can use the CNT electrode for highly localized electrochemical impedance measurements below 1 kHz. Considering an equivalent circuit and the nanoscopic dimensions of the CNT electrode, we demonstrated that the constant impedance was governed by diffusion impedance, whereas the solution resistance, charge-transfer resistance and double-layer capacitance were negligible. (paper)

  5. Detection of irradiated potatoes by impedance measurements

    International Nuclear Information System (INIS)

    Hayashi, Toru; Sugiyama, Junnichi; Otobe, Kazuki; Todoriki, Setsuko

    1993-01-01

    The impedance ratio at 5kHz to 50kHz (Z 6K /Z 50K ) determined at 22degC at an apical region of potato tuber which was pre-incubated at 22degC for 3 days or longer resulted in the best detection of radian treatment. Irradiated potatoes of 10 cultivars could be detected with this method, and potatoes 'Danshaku' commercially irradiated at Shihoro could be distinguished from unirradiated 'Danshaku'. (author)

  6. Low diagnostic value of respiratory impedance measurements in children

    NARCIS (Netherlands)

    Cuijpers, CEJ; Wesseling, GJ; Kessels, AGH; Swaen, GMH; Mertens, PLJM; deKok, ME; Broer, J; Sturmans, F; Wouters, EFM

    The aim of this study was to determine whether impedance values in children with various chronic respiratory complaints differed from those observed in symptom-free children. Respiratory impedance was measured using the forced oscillation technique in 1,776 Dutch children aged 6-12 yrs. In addition

  7. MEASURED TRANSVERSE COUPLING IMPEDANCE OF RHIC INJECTION AND ABORT KICKERS

    International Nuclear Information System (INIS)

    HAHN, H.; DAVINO, D.

    2001-01-01

    Concerns regarding possible transverse instabilities in RHIC and the SNS pointed to the need for measurements of the transverse coupling impedance of ring components. The impedance of the RHIC injection and abort kicker was measured using the conventional method based on the S 21 forward transmission coefficient. A commercial 450 Ω twin-wire Lecher line were used and the data was interpreted via the log-formula. All measurements, were performed in test stands fully representing operational conditions including pulsed power supplies and connecting cables. The measured values for the transverse coupling impedance in kick direction and perpendicular to it are comparable in magnitude, but differ from Handbook predictions

  8. Detection of thoracic vascular structures by electrical impedance tomography: a systematic assessment of prominence peak analysis of impedance changes.

    Science.gov (United States)

    Wodack, K H; Buehler, S; Nishimoto, S A; Graessler, M F; Behem, C R; Waldmann, A D; Mueller, B; Böhm, S H; Kaniusas, E; Thürk, F; Maerz, A; Trepte, C J C; Reuter, D A

    2018-02-28

    Electrical impedance tomography (EIT) is a non-invasive and radiation-free bedside monitoring technology, primarily used to monitor lung function. First experimental data shows that the descending aorta can be detected at different thoracic heights and might allow the assessment of central hemodynamics, i.e. stroke volume and pulse transit time. First, the feasibility of localizing small non-conductive objects within a saline phantom model was evaluated. Second, this result was utilized for the detection of the aorta by EIT in ten anesthetized pigs with comparison to thoracic computer tomography (CT). Two EIT belts were placed at different thoracic positions and a bolus of hypertonic saline (10 ml, 20%) was administered into the ascending aorta while EIT data were recorded. EIT images were reconstructed using the GREIT model, based on the individual's thoracic contours. The resulting EIT images were analyzed pixel by pixel to identify the aortic pixel, in which the bolus caused the highest transient impedance peak in time. In the phantom, small objects could be located at each position with a maximal deviation of 0.71 cm. In vivo, no significant differences between the aorta position measured by EIT and the anatomical aorta location were obtained for both measurement planes if the search was restricted to the dorsal thoracic region of interest (ROIs). It is possible to detect the descending aorta at different thoracic levels by EIT using an intra-aortic bolus of hypertonic saline. No significant differences in the position of the descending aorta on EIT images compared to CT images were obtained for both EIT belts.

  9. Validation of Standing Wave Liner Impedance Measurement Method, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Hersh Acoustical Engineering, Inc. proposes to establish the feasibility and practicality of using the Standing Wave Method (SWM) to measure the impedance of...

  10. Reliability of impedance cardiography in measuring central haemodynamics

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Stadeager, C

    1991-01-01

    The purpose of the study described here was to investigate the reliability of impedance cardiography (IC) in measuring cardiac output (CO) and central blood volume. Absolute values and changes in these variables obtained by impedance cardiography and by isotope- or thermodilution techniques were...... suitable for repeated measurements in studies on the haemodynamic effects of physiological or pharmacological intervention. Impedance cardiography is sufficiently reliable for comparison of absolute values of CO between different groups of patients. We cannot recommend impedance cardiography...... healthy subjects and in 25 unmedicated patients with ischaemic heart disease. We obtained significant correlations between absolute values (y = 0.68x + 1.48) and changes (y = 1.00x + 0.0003) in CO measured by IC and isotope- or thermodilution. IC significantly overestimated absolute values of CO (P less...

  11. Measured longitudinal beam impedance of booster gradient magnets; TOPICAL

    International Nuclear Information System (INIS)

    James L Crisp and Brian J. Fellenz

    2001-01-01

    The Booster gradient magnets have no vacuum pipe which forces the beam image current to flow along the laminated pole tips. Both D and F style magnets were measured with a stretched wire to determine the longitudinal beam impedance caused by these laminations. Results are compared to calculations done 30 years ago. The inductive part of the magnet impedance is interesting because it partially compensates for the negative inductance effects of space charge on the beam. An R/L circuit consisting of 37K(center d ot) in parallel with between 40 and 100uH is a reasonable approximation to the total impedance of Booster magnet laminations

  12. Microfluidic device for cell capture and impedance measurement.

    Science.gov (United States)

    Jang, Ling-Sheng; Wang, Min-How

    2007-10-01

    This work presents a microfluidic device to capture physically single cells within microstructures inside a channel and to measure the impedance of a single HeLa cell (human cervical epithelioid carcinoma) using impedance spectroscopy. The device includes a glass substrate with electrodes and a PDMS channel with micro pillars. The commercial software CFD-ACE+ is used to study the flow of the microstructures in the channel. According to simulation results, the probability of cell capture by three micro pillars is about 10%. An equivalent circuit model of the device is established and fits closely to the experimental results. The circuit can be modeled electrically as cell impedance in parallel with dielectric capacitance and in series with a pair of electrode resistors. The system is operated at low frequency between 1 and 100 kHz. In this study, experiments show that the HeLa cell is successfully captured by the micro pillars and its impedance is measured by impedance spectroscopy. The magnitude of the HeLa cell impedance declines at all operation voltages with frequency because the HeLa cell is capacitive. Additionally, increasing the operation voltage reduces the magnitude of the HeLa cell because a strong electric field may promote the exchange of ions between the cytoplasm and the isotonic solution. Below an operating voltage of 0.9 V, the system impedance response is characteristic of a parallel circuit at under 30 kHz and of a series circuit at between 30 and 100 kHz. The phase of the HeLa cell impedance is characteristic of a series circuit when the operation voltage exceeds 0.8 V because the cell impedance becomes significant.

  13. Vascular Reactivity: Evaluation of an acute suprasystolic occlusion with impedance plethysmography

    International Nuclear Information System (INIS)

    Herrera, M C; Bonaudo, M; Conde, A; Palavecino, L

    2007-01-01

    In the clinical set, the evaluation of endothelium- dependent vasodilator response of large vessels is carried out using ultrasound equipment for vascular flow determinations and during administration of vasoactive drugs. This work proposes to use a substantially cheaper technique and a sustained cuff arterial occlusion in order to cause vasodilation. Impedance plethysmography is used to detect the arterial pulse wave over radial artery while the forearm is occluded by above the recording site. From these plethysmographic waves, three indexes and their changes -between control and maximal response post-occlusion- were calculated. 33 complete records obtained from healthy low-risk volunteers were analyzed. Between control and post-occlusion maximal response, 'average percentual change of pulse wave amplitude' were (35±13)%, 'stiffness index' did not show significant differences (6,38±0,98 vs 6,38±0,94 and 'reflection index' was significant lower (58±15 vs 35±16)%. These results indicate that: 1- cuff occlusion maneuver was effective to cause endothelium-dependent vasodilation, 2-changes of pulse wave amplitude and reflection index could be used as markers of athero-arteriosclerotic damage in the vascular bed, even in sub-clinical conditions

  14. Energy storage cell impedance measuring apparatus, methods and related systems

    Science.gov (United States)

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.

    2017-12-26

    Energy storage cell impedance testing devices, circuits, and related methods are disclosed. An energy storage cell impedance measuring device includes a sum of sinusoids (SOS) current excitation circuit including differential current sources configured to isolate a ground terminal of the differential current sources from a positive terminal and a negative terminal of an energy storage cell. A method includes applying an SOS signal comprising a sum of sinusoidal current signals to the energy storage cell with the SOS current excitation circuit, each of the sinusoidal current signals oscillating at a different one of a plurality of different frequencies. The method also includes measuring an electrical signal at a positive terminal and a negative terminal of the energy storage cell, and computing an impedance of the energy storage cell at each of the plurality of different frequencies using the measured electrical signal.

  15. Electrical impedance spectroscopy measurements to estimate the ...

    Indian Academy of Sciences (India)

    Administrator

    The reviews of these studies were presented by Kahraman ... kind of solid or liquid material: ionic, semi-conducting, mixed electronic–ionic and .... the rock sample and its response was measured at room temperature. Figure 5 indicates the ...

  16. Impedance technique for measuring dielectrophoretic collection of microbiological particles

    CERN Document Server

    Allsopp, D W E; Brown, A P; Betts, W B

    1999-01-01

    Measurement of the impedance change resulting from the collection of microbiological particles at coplanar electrodes is shown to be an effective and potentially quantitative method of detecting dielectrophoresis. Strong correlations between the frequency-dependent dielectrophoretic collection characteristics measured by impedance change and those observed using an established counting method based on image analysis have been obtained for Escherichia coli. In addition it is shown that the new electrical method can be used to sense dielectrophoretic collection of 19 nm diameter latex beads, particles too small to be resolved by conventional optical detection systems. (author)

  17. Signal Processing for the Impedance Measurement on an Electrochemical Generator

    Directory of Open Access Journals (Sweden)

    El-Hassane AGLZIM

    2008-04-01

    Full Text Available Improving the life time of batteries or fuel cells requires the optimization of components such as membranes and electrodes and enhancement of the flow of gases [1], [2]. These goals could be reached by using a real time measurement on loaded generator. The impedance spectroscopy is a new way that was recently investigated. In this paper, we present an electronic measurement instrumentation developed in our laboratory to measure and plot the impedance of a loaded electrochemical generator like batteries and fuel cells. Impedance measures were done according to variations of the frequency in a larger band than what is usually used. The electronic instrumentation is controlled by Hpvee® software which allows us to plot the Nyquist graph of the electrochemical generator impedance. The theoretical results obtained in simulation under Pspice® confirm the choice of the method and its advantage. For safety reasons, the experimental preliminary tests were done on a 12 V vehicle battery, having an input current of 330 A and a capacity of 40 Ah and are now extended to a fuel cell. The results were plotted at various nominal voltages of the battery (12.7 V, 10 V, 8 V and 5 V and with two imposed currents (0.6 A and 4 A. The Nyquist diagram resulting from the experimental data enable us to show an influence of the load of the battery on its internal impedance. The similitude in the graph form and in order of magnitude of the values obtained (both theoretical and practical enables us to validate our electronic measurement instrumentation. Different sensors (temperature, pressure were placed around the device under test (DUT. These influence parameters were permanently recorded. Results presented here concern a classic loaded 12 V vehicle battery. The Nyquist diagram resulting from the experimental data confirms the influence of the load of the DUT on its internal impedance.

  18. Transverse impedance measurement using response matrix fit method at APS

    International Nuclear Information System (INIS)

    Sajaev, V.

    2007-01-01

    The Advanced Photon Source (APS) is a third-generation synchrotron light source based on a 7-GeV electron storage ring. In third-generation light sources the synchrotron radiation is mainly produced in undulators. In order to achieve high photon flux and tunability, the magnet gap in undulators has to be as small as possible. Therefore, the undulators are installed on dedicated small-gap insertion device (ID) vacuum chambers. APS has thirty-five 5-m-long straight sections available for undulators. At the time of the measurements, there were 31 straight sections occupied with various insertion devices, and 4 straight sections were still empty. Most of the ID vacuum chambers have a 8-mm in-vacuum gap, and two chambers have a 5-mm gap. These narrow-gap vacuum chambers are believed to be the main source of the transverse impedance of the machine. One can measure the combined impedance by measuring the transverse tune slope with single-bunch current. Comparing this slope before and after installation of the narrow-gap vacuum chamber, one can deduce the impedance of the chamber. It is difficult to accurately measure the change in the tune slope after one or a few new ID chambers are installed. If several identical ID vacuum chambers are installed over a period of time, then one can estimate the contribution of one ID chamber. Over the last few years there have been a number of attempts to measure the impedance of separate components of accelerators. Phase-advance measurements from beam position monitor (BPM) turn-by-turn histories were used at LEP to measure the impedance distribution around the ring. Researches at LEP were able to fit average impedance in the long sections of the LEP arc and determine the impedance of the rf sections. The method was tried at APS; however, the accuracy of the measurements was not enough to determine the small impedance of a single ID vacuum chamber. There is also a different approach that uses local orbit bumps to probe different parts

  19. FLEXIBLE PH SENSOR WITH POLYANILINE LAYER BASED ON IMPEDANCE MEASUREMENT

    OpenAIRE

    Chuang, Cheng-Hsin; Wu, Hsun-Pei; Chen, Cheng-Ho; Wu, Peng-Rong

    2012-01-01

    A flexible sensor with conducting polyaniline layer for detecting pH value based on the impedance measurement is fabricated and demonstrated in this study. The pH sensor consists of an interdigital electrode array on a flexible printed circuit and a thin-film polyaniline as the sensing layer. As the conductivity of polyaniline depends on the redox state, the impedance change of the polyaniline after it has reacted with different pH value solutions works as the sensing mechanism. In order to o...

  20. Nuclear EMP: stripline test method for measuring transfer impedance

    International Nuclear Information System (INIS)

    Miller, J.S.

    1975-11-01

    A method for measuring the transfer impedance of flat metal joints for frequencies to 100 MHz has been developed which makes use of striplines. The stripline method, which has similarities to the quadraxial method used for cylindrical components, is described and sets of test results are given. The transfer impedance of a simple joint is modeled as a spurious hyperbolic curve, and a close curve fit to transfer impedance test data from various samples is demonstrated for both the stripline and the quadraxial methods. Validity checks of the test data are discussed using the curve model and other criteria. The method was developed for testing riveted joints which form the avionics bays on B-1s. The joints must provide shielding from EMP currents

  1. Electrical impedance measured changes in thoracic fluid content during thoracentesis

    DEFF Research Database (Denmark)

    Petersen, J R; Jensen, B V; Drabaek, H

    1994-01-01

    In patients (seven females and 11 males) with pleural effusion due to pulmonary (n = 13) or cardiac disease (n = 5) the change in baseline transthoracic impedance (Z0) was measured by electrical impedance (BoMed's NCCOM-3, 70 kHz) during thoracentesis. Data were obtained before and after withdrawal...... of each 500 ml, and at the end of the thoracentesis. We found a close linear correlation (r = 0.97) between changes in Z0 and the volume of aspirated pleural effusion (y = 0.415.x+0.093). The variability of the estimated thoracic fluid volumes was analysed with a plot of the residuals from the regression...... line, and we found that changes in thoracic fluid volume estimated by impedance technique would be within +/- 302 ml (= 2 SD). However, the absolute value of Z0 before thoracentesis could not differentiate the group of patients with pleural effusion from normal subjects (n = 28)....

  2. Electrode-less measurement of cell layers impedance

    Czech Academy of Sciences Publication Activity Database

    Krůšek, Jan; Ďaďo, S.

    2014-01-01

    Roč. 63, č. 6 (2014), s. 705-711 ISSN 0862-8408 R&D Projects: GA ČR(CZ) GBP304/12/G069 Institutional support: RVO:67985823 Keywords : cell impedance measurement * transepithelial resistance Subject RIV: ED - Physiology Impact factor: 1.293, year: 2014

  3. Measurement of Phase Dependent Impedance for 3-phase Diode Rectifier

    DEFF Research Database (Denmark)

    Kwon, Jun Bum; Wang, Xiongfei; Bak, Claus Leth

    2016-01-01

    This paper presents a new method to measure the phase dependent impedance from an experimental set up. Though most of power electronics based system is gradually migrating to IGBT based voltage source converter due to their controllability, the rectifier composed of diode or thyristor components...

  4. Shunt impedance measurement of the APS BBC injector

    International Nuclear Information System (INIS)

    Sun, Y.E.; Lewellen, J.W.

    2006-01-01

    The injector test stand (ITS) at Advanced Photon Source (APS) presently incorporates a ballistic bunch compression (BBC) gun, and it is used as a beam source for a number of experiments, including THz generation, beam position monitor testing for the Linac Coherent Light Source (LCLS), novel cathode testing, and radiation therapy source development. The BBC gun uses three independently powered and phased rf cavities, one cathode cell, and two full cells to provide beam energies from 2 to 10 MeV with variable energy spread, energy chirp, and, to an extent, bunch duration. The shunt impedance of an rf accelerator determines how effectively the accelerator can convert supplied rf power to accelerating gradient. The calculation of the shunt impedance can be complicated if the beam energy changes substantially during its transit through a cavity, such as in a cathode cell. We present the results of direct measurements of the shunt impedance of the APS BBC gun on an individual cavity basis, including the cathode cell, and report on achieved gradients. We also present a comparison of the measured shunt impedance with theoretical values calculated from the rf models of the cavities.

  5. Bench measurements of coupling impedance of AGS Booster components

    International Nuclear Information System (INIS)

    Ratti, A.; Shea, T.J.

    1991-01-01

    Quantifying instability thresholds for modern synchrotrons and storage rings requires some knowledge of the accelerator's coupling impedance. To this end, the wire technique has been implemented to measure the longitudinal coupling impedance of AGS Booster devices. The techniques are being refined to allow measurement of RHIC devices at higher frequencies. All the measurements are performed using an HP 8753 Network Analyzer controlled via GPIB by a Macintosh computer. The computer provides an environment for automated data acquisition, data analysis, and report generation. Resistive matches between the 50ω analyzer cables and the 300ω pipe-and-wire structure allow the use of a simple response calibration in the measurement of S21 to 400MHz. Results from ferrite loaded rf cavities, position monitors and kickers are presented. 4 refs., 4 figs

  6. Portable audio electronics for impedance-based measurements in microfluidics

    International Nuclear Information System (INIS)

    Wood, Paul; Sinton, David

    2010-01-01

    We demonstrate the use of audio electronics-based signals to perform on-chip electrochemical measurements. Cell phones and portable music players are examples of consumer electronics that are easily operated and are ubiquitous worldwide. Audio output (play) and input (record) signals are voltage based and contain frequency and amplitude information. A cell phone, laptop soundcard and two compact audio players are compared with respect to frequency response; the laptop soundcard provides the most uniform frequency response, while the cell phone performance is found to be insufficient. The audio signals in the common portable music players and laptop soundcard operate in the range of 20 Hz to 20 kHz and are found to be applicable, as voltage input and output signals, to impedance-based electrochemical measurements in microfluidic systems. Validated impedance-based measurements of concentration (0.1–50 mM), flow rate (2–120 µL min −1 ) and particle detection (32 µm diameter) are demonstrated. The prevailing, lossless, wave audio file format is found to be suitable for data transmission to and from external sources, such as a centralized lab, and the cost of all hardware (in addition to audio devices) is ∼10 USD. The utility demonstrated here, in combination with the ubiquitous nature of portable audio electronics, presents new opportunities for impedance-based measurements in portable microfluidic systems. (technical note)

  7. Ionic conductivity measurements of zirconia under pressure using impedance spectroscopy

    International Nuclear Information System (INIS)

    Takebe, H; Sakamoto, D; Ohtaka, O; Fukui, H; Yoshiasa, A; Yamanaka, T; Ota, K; Kikegawa, T

    2002-01-01

    We have set up an electrical conductivity measurement system under high-pressure and high-temperature conditions with a multi-anvil high-pressure apparatus using an AC complex impedance method. With this system, we have successfully measured the electrical conductivity of stabilized ZrO 2 (Y 2 O 3 -ZrO 2 solid solution) under pressures up to 5 GPa in the temperature range from 300 to 1200 K. The electrical conductivities obtained under pressure are compatible with those of previous results measured at ambient pressure

  8. Determination of complex microcalorimeter parameters with impedance measurements

    International Nuclear Information System (INIS)

    Saab, T.; Bandler, S.R.; Chervenak, J.; Figueroa-Feliciano, E.; Finkbeiner, F.; Iyomoto, N.; Kelley, R.L.; Kilbourne, C.A.; Lindeman, M.A.; Porter, F.S.; Sadleir, J.

    2006-01-01

    The proper understanding and modeling of a microcalorimeter's response requires accurate knowledge of a handful of parameters, such as C, G, α. While a few of these parameters are directly determined from the IV characteristics, some others, notoriously the heat capacity (C) and α, appear in degenerate combinations in most measurable quantities. The consideration of a complex microcalorimeter leads to an added ambiguity in the determination of the parameters. In general, the dependence of the microcalorimeter's complex impedance on these various parameters varies with frequency. This dependence allows us to determine individual parameters by fitting the prediction of the microcalorimeter model to impedance data. In this paper we describe efforts at characterizing the Goddard X-ray microcalorimeters. With the parameters determined by this method, we compare the pulse shape and noise spectra predictions to data taken with the same devices

  9. Nuclear radiation-warning detector that measures impedance

    Science.gov (United States)

    Savignac, Noel Felix; Gomez, Leo S; Yelton, William Graham; Robinson, Alex; Limmer, Steven

    2013-06-04

    This invention is a nuclear radiation-warning detector that measures impedance of silver-silver halide on an interdigitated electrode to detect light or radiation comprised of alpha particles, beta particles, gamma rays, X rays, and/or neutrons. The detector is comprised of an interdigitated electrode covered by a layer of silver halide. After exposure to alpha particles, beta particles, X rays, gamma rays, neutron radiation, or light, the silver halide is reduced to silver in the presence of a reducing solution. The change from the high electrical resistance (impedance) of silver halide to the low resistance of silver provides the radiation warning that detected radiation levels exceed a predetermined radiation dose threshold.

  10. Modern Trends in Imaging XI: Impedance Measurements in the Biomedical Sciences

    Directory of Open Access Journals (Sweden)

    Frederick D. Coffman

    2012-01-01

    Full Text Available Biological organisms and their component organs, tissues and cells have unique electrical impedance properties. Impedance properties often change with changes in structure, composition, and metabolism, and can be indicative of the onset and progression of disease states. Over the past 100 years, instruments and analytical methods have been developed to measure the impedance properties of biological specimens and to utilize these measurements in both clinical and basic science settings. This chapter will review the applications of impedance measurements in the biomedical sciences, from whole body analysis to impedance measurements of single cells and cell monolayers, and how cellular impedance measuring instruments can now be used in high throughput screening applications.

  11. Determination of time delay between ventricles contraction using impedance measurements

    International Nuclear Information System (INIS)

    Lewandowska, M; Poliński, A; Wtorek, J

    2013-01-01

    The paper presents a novel approach to assessment of ventricular dyssynchrony basing on multichannel electrical impedance measurements. Using a proper placement of electrodes, the sensitivity approach allows estimating time difference between chambers contraction from over determined nonlinear system of equations. The theoretical considerations which include Finite Element Method simulations were verified using measurements on healthy 28 year's old woman. The nonlinear least squares method was applied to obtain a time difference between heart chambers contraction. The obtained value was in a good agreement with theoretical values found in literature.

  12. Plasma diagnosis of RF discharge by using impedance measurement

    International Nuclear Information System (INIS)

    Huang Jianjun; Teuner, D.

    2001-01-01

    It is presented that the method known from network analysis with home-made probe and experimental setup to measure current, voltage and phase angle of RF discharge in He gas more accurately. The sheath thickness and the real and imaginary parts of the plasma impedance were obtained by using the equivalent circuit model and taking account stray capacitances of the set-up. In addition, making use of Godyak's RF discharge simple model, the electron density in the discharge was calculated at different pressure and current density

  13. Electrical impedance spectroscopy for measuring the impedance response of carbon-fiber-reinforced polymer composite laminates

    KAUST Repository

    Almuhammadi, Khaled; Bera, Tushar Kanti; Lubineau, Gilles

    2017-01-01

    impedance spectroscopy response at various frequencies of laminates chosen to be representative of classical layups employed in composite structures. We clarify the relationship between the frequency of the electrical current, the conductivity of the surface

  14. Auditory evoked field measurement using magneto-impedance sensors

    Energy Technology Data Exchange (ETDEWEB)

    Wang, K., E-mail: o-kabou@echo.nuee.nagoya-u.ac.jp; Tajima, S.; Song, D.; Uchiyama, T. [Graduate School of Engineering, Nagoya University, Nagoya (Japan); Hamada, N.; Cai, C. [Aichi Steel Corporation, Tokai (Japan)

    2015-05-07

    The magnetic field of the human brain is extremely weak, and it is mostly measured and monitored in the magnetoencephalography method using superconducting quantum interference devices. In this study, in order to measure the weak magnetic field of the brain, we constructed a Magneto-Impedance sensor (MI sensor) system that can cancel out the background noise without any magnetic shield. Based on our previous studies of brain wave measurements, we used two MI sensors in this system for monitoring both cerebral hemispheres. In this study, we recorded and compared the auditory evoked field signals of the subject, including the N100 (or N1) and the P300 (or P3) brain waves. The results suggest that the MI sensor can be applied to brain activity measurement.

  15. Measurement scheme of kicker impedances via beam-induced voltages of coaxial cables

    Energy Technology Data Exchange (ETDEWEB)

    Shobuda, Yoshihiro, E-mail: yoshihiro.shobuda@j-parc.jp [J-PARC Center, JAEA and KEK, 2-4 Shirakata Shirane, Tokaimura, Nakagun, Ibaraki 319-1195 (Japan); Irie, Yoshiro [KEK, High Energy Accelerator Research Organization, 1-1 Oho, Tsukuba, Ibaraki 305-0801 (Japan); Toyama, Takeshi; Kamiya, Junichiro [J-PARC Center, JAEA and KEK, 2-4 Shirakata Shirane, Tokaimura, Nakagun, Ibaraki 319-1195 (Japan); Watanabe, Masao [Ministry of Education, Culture, Sports, Science and Technology, 3-2-2 Kasumigaseki, Chiyoda, Tokyo 100-8959 (Japan)

    2013-06-11

    A new theory, which satisfies the causality condition, is developed to describe impedances of kicker magnets with coaxial cables. The theoretical results well describe measurement results, which are obtained by standard wire methods. On the other hand, when beams pass through the kicker, voltages are induced at the terminals of coaxial cables. In other words, by analyzing the voltages, the kicker impedance for the beams can be obtained. The observed impedances are consistent with the theoretical results. The theory describes the impedance for non-relativistic beams, as well. The theoretical, simulation and measurement results indicate that the horizontal kicker impedance is drastically reduced by the non-relativistic effect. -- Highlights: ► We develop an innovative method to measure kicker impedance including power cable. ► By analyzing voltages at the ends of coaxial cables, the impedance is derived. ► The horizontal impedance is reduced as the beam becomes non-relativistic.

  16. Measurements of the dynamic input impedance of a dc SQUID

    International Nuclear Information System (INIS)

    Hilbert, C.; Clarke, J.

    1985-01-01

    The impedance of a circuit coupled magnetically via a mutual inductance M/sub i/ to a dc SQUID of geometric inductance L is modified by the dynamic input impedance of the SQUID, which can be characterized by the flux-to-current transfer function J/sub Phi/approx. =partialJ/partialPhi; J is the current circulating in the SQUID loop and ∫ is the flux applied to the loop. At the same time, the SQUID is modified by the presence of the input circuit in the lumped circuit approximation, one expects its inductance to be reduced to L'(1-α/sub e/ 2 )L, where α/sub e/ is an effective coupling coefficient. Calculations of J/sub Phi/ using an analog simulator are described and presented in the form of a dynamic inductance L and a dynamic resistance R versus bias current I and Phi. Experimental measurements of L and R were made on a planar, thin-film SQUID tightly coupled to a spiral input coil that was connected in series with a capacitor C/sub i/ to form a resonant circuit. Thus, J/sub Phi/ was determined from the change in the resonant frequency and quality factor of this circuit as a function of I and Phi. At low bias currents (low Josephson frequencies) the measured values of L were in reasonable agreement with values simulated for the reduced SQUID, while at higher bias currents (higher Josephson frequencies) the measured values were in better agreement with values simulated for the unscreened SQUID. Similar conclusions were reached in the comparison of the experimental and simulated values of the flux-to-voltage transfer function V/sub Phi/

  17. Evaluation of different methods for measuring the impedance of Lithium-ion batteries during ageing

    DEFF Research Database (Denmark)

    Stroe, Daniel Loan; Swierczynski, Maciej Jozef; Stroe, Ana-Irina

    2015-01-01

    The impedance represents one of the most important performance parameters of the Lithium-ion batteries since it used for power capability calculations, battery pack and system design, cooling system design and also for state-of-health estimation. In the literature, different approaches...... are presented for measuring the impedance of Lithium-ion batteries and electrochemical impedance spectroscopy and dc current pulses are the most used ones; each of these approaches has its own advantages and drawbacks. The goal of this paper is to investigate which of the most encountered impedance measurement...... approaches is the most suitable for measuring the impedance of Lithium-ion batteries during ageing....

  18. Bench measurement of vacuum chamber impedances with wires

    International Nuclear Information System (INIS)

    Shafer, R.E.

    1979-01-01

    Particle beams travelling in an accelerator or storage ring vacuum chamber produce electric and magnetic fields which interact with the walls of the chamber. The induced wall currents in turn generate secondary fields which can interact with the beam, giving rise to both energy loss and other effects which can cause beam instability. In many simple geometries these effects can be calculated. In more complex geometries the calculations are difficult and very approximate. For this reason it is important that the effects be measured if possible prior to installation. As accelerators become larger and the number of vacuum chamber components more numerous, and as more severe beam intensity and stability requirements are placing lower limits on the longitudinal and transverse impedances, a less than adequate component will be more likely to limit machine performance

  19. Wideband impedance measurements and modeling of DC motors for EMI predictions

    NARCIS (Netherlands)

    Diouf, F.; Leferink, Frank Bernardus Johannes; Duval, Fabrice; Bensetti, Mohamed

    2015-01-01

    In electromagnetic interference prediction, dc motors are usually modeled as a source and a series impedance. Previous researches only include the impedance of the armature, while neglecting the effect of the motor's rotation. This paper aims at measuring and modeling the wideband impedance of a dc

  20. An Effective Measured Data Preprocessing Method in Electrical Impedance Tomography

    Directory of Open Access Journals (Sweden)

    Chenglong Yu

    2014-01-01

    Full Text Available As an advanced process detection technology, electrical impedance tomography (EIT has widely been paid attention to and studied in the industrial fields. But the EIT techniques are greatly limited to the low spatial resolutions. This problem may result from the incorrect preprocessing of measuring data and lack of general criterion to evaluate different preprocessing processes. In this paper, an EIT data preprocessing method is proposed by all rooting measured data and evaluated by two constructed indexes based on all rooted EIT measured data. By finding the optimums of the two indexes, the proposed method can be applied to improve the EIT imaging spatial resolutions. In terms of a theoretical model, the optimal rooting times of the two indexes range in [0.23, 0.33] and in [0.22, 0.35], respectively. Moreover, these factors that affect the correctness of the proposed method are generally analyzed. The measuring data preprocessing is necessary and helpful for any imaging process. Thus, the proposed method can be generally and widely used in any imaging process. Experimental results validate the two proposed indexes.

  1. Electrical impedance spectroscopy for measuring the impedance response of carbon-fiber-reinforced polymer composite laminates

    KAUST Repository

    Almuhammadi, Khaled

    2017-02-16

    Techniques that monitor the change in the electrical properties of materials are promising for both non-destructive testing and structural health monitoring of carbon-fiber-reinforced polymers (CFRPs). However, achieving reliable monitoring using these techniques requires an in-depth understanding of the impedance response of these materials when subjected to an alternating electrical excitation, information that is only partially available in the literature. In this work, we investigate the electrical impedance spectroscopy response at various frequencies of laminates chosen to be representative of classical layups employed in composite structures. We clarify the relationship between the frequency of the electrical current, the conductivity of the surface ply and the probing depth for different CFRP configurations for more efficient electrical signal-based inspections. We also investigate the effect of the amplitude of the input signal.

  2. Measurements of Electric Performance and Impedance of a 75 Ah NMC Lithium Battery Module

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Engelbrecht, Kurt

    2012-01-01

    and the Laplace transformed excitation signal technique which each have pros and cons. By combining the two impedance measurement techniques we are able to reduce the measurement time by a factor of 20 relative to ordinary single-sine measurements. Further we use the impedance measurements to calculate...

  3. Local impedance measurement of an electrode/single-pentacene-grain interface by frequency-modulation scanning impedance microscopy

    Energy Technology Data Exchange (ETDEWEB)

    Kimura, Tomoharu; Yamada, Hirofumi, E-mail: h-yamada@kuee.kyoto-u.ac.jp [Department of Electronic Science and Engineering, Kyoto University, Kyoto 615-8510 (Japan); Kobayashi, Kei [Department of Electronic Science and Engineering, Kyoto University, Kyoto 615-8510 (Japan); The Hakubi Center for Advanced Research, Kyoto University, Kyoto 615-8520 (Japan)

    2015-08-07

    The device performances of organic thin film transistors are often limited by the metal–organic interface because of the disordered molecular layers at the interface and the energy barriers against the carrier injection. It is important to study the local impedance at the interface without being affected by the interface morphology. We combined frequency modulation atomic force microscopy with scanning impedance microscopy (SIM) to sensitively measure the ac responses of the interface to an ac voltage applied across the interface and the dc potential drop at the interface. By using the frequency-modulation SIM (FM-SIM) technique, we characterized the interface impedance of a Pt electrode and a single pentacene grain as a parallel circuit of a contact resistance and a capacitance. We found that the reduction of the contact resistance was caused by the reduction of the energy level mismatch at the interface by the FM-SIM measurements, demonstrating the usefulness of the FM-SIM technique for investigation of the local interface impedance without being affected by its morphology.

  4. Analytic modeling, simulation and interpretation of broadband beam coupling impedance bench measurements

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, U., E-mail: niedermayer@temf.tu-darmstadt.de [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Eidam, L. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); Boine-Frankenheim, O. [Institut für Theorie Elektromagnetischer Felder (TEMF), Technische Universität Darmstadt, Schloßgartenstraße 8, 64289 Darmstadt (Germany); GSI Helmholzzentrum für Schwerionenforschung, Planckstraße 1, 64291 Darmstadt (Germany)

    2015-03-11

    First, a generalized theoretical approach towards beam coupling impedances and stretched-wire measurements is introduced. Applied to a circular symmetric setup, this approach allows to compare beam and wire impedances. The conversion formulas for TEM scattering parameters from measurements to impedances are thoroughly analyzed and compared to the analytical beam impedance solution. A proof of validity for the distributed impedance formula is given. The interaction of the beam or the TEM wave with dispersive material such as ferrite is discussed. The dependence of the obtained beam impedance on the relativistic velocity β is investigated and found as material property dependent. Second, numerical simulations of wakefields and scattering parameters are compared. The applicability of scattering parameter conversion formulas for finite device length is investigated. Laboratory measurement results for a circularly symmetric test setup, i.e. a ferrite ring, are shown and compared to analytic and numeric models. The optimization of the measurement process and error reduction strategies are discussed.

  5. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Science.gov (United States)

    Kumar, Mukesh; Babbar, L. K.; Deo, R. K.; Puntambekar, T. A.; Senecha, V. K.

    2018-05-01

    The transfer impedance is a very important parameter of a beam position monitor (BPM) which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables). This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  6. Modified coaxial wire method for measurement of transfer impedance of beam position monitors

    Directory of Open Access Journals (Sweden)

    Mukesh Kumar

    2018-05-01

    Full Text Available The transfer impedance is a very important parameter of a beam position monitor (BPM which relates its output signal with the beam current. The coaxial wire method is a standard technique to measure transfer impedance of the BPM. The conventional coaxial wire method requires impedance matching between coaxial wire and external circuits (vector network analyzer and associated cables. This paper presents a modified coaxial wire method for bench measurement of the transfer impedance of capacitive pickups like button electrodes and shoe box BPMs. Unlike the conventional coaxial wire method, in the modified coaxial wire method no impedance matching elements have been used between the device under test and the external circuit. The effect of impedance mismatch has been solved mathematically and a new expression of transfer impedance has been derived. The proposed method is verified through simulation of a button electrode BPM using cst studio suite. The new method is also applied to measure transfer impedance of a button electrode BPM developed for insertion devices of Indus-2 and the results are also compared with its simulations. Close agreement between measured and simulation results suggests that the modified coaxial wire setup can be exploited for the measurement of transfer impedance of capacitive BPMs like button electrodes and shoe box BPM.

  7. A Harmonic Impedance Measurement System for Reduction of Harmonics in the Electricity Grid

    NARCIS (Netherlands)

    Heskes, P.J.M.; Myrzik, J.M.A.; Kling, W.L.

    2009-01-01

    This paper describes the development of a Complex Harmonic Impedance Measurement system, called the CHIME-system. This system performs on-line impedance measurements in the electricity grid and will be designed for implementation in Digital Signal Processor (DSP) control systems of grid-connected

  8. A harmonic impedance measurement system for reduction of harmonics in the electricity grid

    NARCIS (Netherlands)

    Heskes, P.J.M.; Myrzik, J.M.A.; Kling, W.L.

    2009-01-01

    This paper describes the development of a Complex Harmonic Impedance Measurement system, called the CHIME-system. This system performs on-line impedance measurements in the electricity grid and will be designed for implementation in Digital Signal Processor (DSP) control systems of grid-connected

  9. A potpourri of impedance measurements at the advanced photon source storage ring

    International Nuclear Information System (INIS)

    Sereno, N.S.; Chae, Y.C.; Harkay, K.C.; Lumpkin, A.H.; Milton, S.V.; Yang, B.X.

    1997-01-01

    Machine coupling impedances were determined in the APS storage ring from measurements of the bunch length, synchronous phase, and synchrotron and betatron tunes vs single-bunch current. The transverse measurements were performed for various numbers of small gap insertion device (ID) chambers installed in the ring. The transverse impedance is determined from measurements of the transverse tunes and bunch length as a function of single-bunch current. The shift in the synchrotron tune was measured as a function of bunch current from which the total cavity impedance was extracted. The loss factor was determined by measuring the relative synchronous phase as a function of bunch current. The longitudinal resistive impedance is calculated using the loss factor dependence on the bunch length. From these results, the authors can estimate what the impedance would be for a full set of ID chambers

  10. Wideband impedance measurements of DC motors under dynamic load conditions

    NARCIS (Netherlands)

    Diouf, F.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes; Duval, Fabrice; Bensetti, Mohamed

    2013-01-01

    One of the principal conducted EMI(electromagnetic interferences) sources of low voltage DC (direct current) motors is the commutation occurring during rotation. In this paper the small-signal impedance of low voltage DC motors under different functioning modes, including the dynamic one is studied

  11. Central Pulsatile Pressure and Flow Relationship in the Time and Frequency Domain to Characterise Hydraulic Input to the Brain and Cerebral Vascular Impedance.

    Science.gov (United States)

    Kim, Mi Ok; O'Rourke, Michael F; Adji, Audrey; Avolio, Alberto P

    2016-01-01

    In the time domain, pulsatile flow and pressure can be characterised as the ratio of the late systolic boost of flow or pressure to the pulse amplitude so as to estimate the hydraulic input to the brain. While vascular impedance has been widely used to represent the load presented to the heart by the systemic circulation, it has not been applied to the cerebral circulation.We set out to study the relationship between the pressure and the flow augmentation index (AIx) in the time domain and to determine cerebral vascular impedance using aortic blood pressure and cerebral blood flow waveforms in the frequency domain. Twenty-four young subjects (aged 21-39 years) were recruited; aortic pressure was derived using SphygmoCor from radial pressure. Flow waveforms were recorded from the middle cerebral artery. In three subjects, we performed the Valsalva manoeuvre to investigate their response to physiological intervention. There was a linear relationship between flow and pressure AIx, and cerebral impedance values were similar to those estimated for low resistance vascular beds. Substantial change in pressure and flow wave contour was observed during the Valsalva manoeuvre; however, the relationship in both the time and the frequency domains were unchanged. This confirms that aortic pressure and cerebral flow waveform can be used to study cerebral impedance.

  12. Accurate position estimation methods based on electrical impedance tomography measurements

    Science.gov (United States)

    Vergara, Samuel; Sbarbaro, Daniel; Johansen, T. A.

    2017-08-01

    Electrical impedance tomography (EIT) is a technology that estimates the electrical properties of a body or a cross section. Its main advantages are its non-invasiveness, low cost and operation free of radiation. The estimation of the conductivity field leads to low resolution images compared with other technologies, and high computational cost. However, in many applications the target information lies in a low intrinsic dimensionality of the conductivity field. The estimation of this low-dimensional information is addressed in this work. It proposes optimization-based and data-driven approaches for estimating this low-dimensional information. The accuracy of the results obtained with these approaches depends on modelling and experimental conditions. Optimization approaches are sensitive to model discretization, type of cost function and searching algorithms. Data-driven methods are sensitive to the assumed model structure and the data set used for parameter estimation. The system configuration and experimental conditions, such as number of electrodes and signal-to-noise ratio (SNR), also have an impact on the results. In order to illustrate the effects of all these factors, the position estimation of a circular anomaly is addressed. Optimization methods based on weighted error cost functions and derivate-free optimization algorithms provided the best results. Data-driven approaches based on linear models provided, in this case, good estimates, but the use of nonlinear models enhanced the estimation accuracy. The results obtained by optimization-based algorithms were less sensitive to experimental conditions, such as number of electrodes and SNR, than data-driven approaches. Position estimation mean squared errors for simulation and experimental conditions were more than twice for the optimization-based approaches compared with the data-driven ones. The experimental position estimation mean squared error of the data-driven models using a 16-electrode setup was less

  13. IMPEDANCE METHOD OF MEASURING OF THE TITRATABLE ACIDITY OF YOGURT

    Directory of Open Access Journals (Sweden)

    Miroslav Vasilev

    2016-10-01

    Full Text Available In the present work are analyzed studies related to changes in the active impedance component of the dairy environment caused by the flow of lactic fermentation and coagulation of casein in milk. The aim of this work was to determine the relationship between the relative change of titratable acidity and the relative change of active impedance component of the dairy environment with lactic fermentation, causing coagulation of the casein in milk. . The data were interpolated with cubic spline, visualizing how when the fat content increases, the electrical resistance increases too. All data, collected during the tests would complement and be used for solving the optimization problem to determine the time of completion of the coagulation in future work.

  14. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Directory of Open Access Journals (Sweden)

    Victor Smaluk

    2014-07-01

    Full Text Available One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  15. Coupling impedance of an in-vacuum undulator: Measurement, simulation, and analytical estimation

    Science.gov (United States)

    Smaluk, Victor; Fielder, Richard; Blednykh, Alexei; Rehm, Guenther; Bartolini, Riccardo

    2014-07-01

    One of the important issues of the in-vacuum undulator design is the coupling impedance of the vacuum chamber, which includes tapered transitions with variable gap size. To get complete and reliable information on the impedance, analytical estimate, numerical simulations and beam-based measurements have been performed at Diamond Light Source, a forthcoming upgrade of which includes introducing additional insertion device (ID) straights. The impedance of an already existing ID vessel geometrically similar to the new one has been measured using the orbit bump method. The measurement results in comparison with analytical estimations and numerical simulations are discussed in this paper.

  16. Microelectrical Impedance Spectroscopy for the Differentiation between Normal and Cancerous Human Urothelial Cell Lines: Real-Time Electrical Impedance Measurement at an Optimal Frequency

    Directory of Open Access Journals (Sweden)

    Yangkyu Park

    2016-01-01

    Full Text Available Purpose. To distinguish between normal (SV-HUC-1 and cancerous (TCCSUP human urothelial cell lines using microelectrical impedance spectroscopy (μEIS. Materials and Methods. Two types of μEIS devices were designed and used in combination to measure the impedance of SV-HUC-1 and TCCSUP cells flowing through the channels of the devices. The first device (μEIS-OF was designed to determine the optimal frequency at which the impedance of two cell lines is most distinguishable. The μEIS-OF trapped the flowing cells and measured their impedance at a frequency ranging from 5 kHz to 1 MHz. The second device (μEIS-RT was designed for real-time impedance measurement of the cells at the optimal frequency. The impedance was measured instantaneously as the cells passed the sensing electrodes of μEIS-RT. Results. The optimal frequency, which maximized the average difference of the amplitude and phase angle between the two cell lines (p<0.001, was determined to be 119 kHz. The real-time impedance of the cell lines was measured at 119 kHz; the two cell lines differed significantly in terms of amplitude and phase angle (p<0.001. Conclusion. The μEIS-RT can discriminate SV-HUC-1 and TCCSUP cells by measuring the impedance at the optimal frequency determined by the μEIS-OF.

  17. Design and Functional Validation of a Complex Impedance Measurement Device for Characterization of Ultrasonic Transducers

    International Nuclear Information System (INIS)

    De-Cock, Wouter; Cools, Jan; Leroux, Paul

    2013-06-01

    This paper presents the design and practical implementation of a complex impedance measurement device capable of characterization of ultrasonic transducers. The device works in the frequency range used by industrial ultrasonic transducers which is below the measurement range of modern high end network analyzers. The device uses the Goertzel algorithm instead of the more common FFT algorithm to calculate the magnitude and phase component of the impedance under test. A theoretical overview is given followed by a practical approach and measurement results. (authors)

  18. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators.

    Science.gov (United States)

    Kim, Pil-Jong; Kim, Hong-Gee; Cho, Byeong-Hoon

    2015-05-01

    The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL). The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC) in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  19. Evaluation of electrical impedance ratio measurements in accuracy of electronic apex locators

    Directory of Open Access Journals (Sweden)

    Pil-Jong Kim

    2015-05-01

    Full Text Available Objectives The aim of this paper was evaluating the ratios of electrical impedance measurements reported in previous studies through a correlation analysis in order to explicit it as the contributing factor to the accuracy of electronic apex locator (EAL. Materials and Methods The literature regarding electrical property measurements of EALs was screened using Medline and Embase. All data acquired were plotted to identify correlations between impedance and log-scaled frequency. The accuracy of the impedance ratio method used to detect the apical constriction (APC in most EALs was evaluated using linear ramp function fitting. Changes of impedance ratios for various frequencies were evaluated for a variety of file positions. Results Among the ten papers selected in the search process, the first-order equations between log-scaled frequency and impedance were in the negative direction. When the model for the ratios was assumed to be a linear ramp function, the ratio values decreased if the file went deeper and the average ratio values of the left and right horizontal zones were significantly different in 8 out of 9 studies. The APC was located within the interval of linear relation between the left and right horizontal zones of the linear ramp model. Conclusions Using the ratio method, the APC was located within a linear interval. Therefore, using the impedance ratio between electrical impedance measurements at different frequencies was a robust method for detection of the APC.

  20. Impedance method for measuring shear elasticity of liquids

    Science.gov (United States)

    Badmaev, B. B.; Dembelova, T. S.; Damdinov, B. B.; Gulgenov, Ch. Zh.

    2017-11-01

    Experimental results of studying low-frequency (74 kHz) shear elasticity of polymer liquids by the impedance method (analogous to the Mason method) are presented. A free-volume thick liquid layer is placed on the horizontal surface of a piezoelectric quartz crystal with dimensions 34.7 × 12 × 5.5 cm. The latter performs tangential vibrations at resonance frequency. The liquid layer experiences shear strain, and shear waves should propagate in it. From the theory of the method, it follows that, with an increase in the layer thickness, both real and imaginary resonance frequency shifts should exhibit damped oscillations and tend to limiting values. For the liquids under study, the imaginary frequency shift far exceeds the real one, which testifies to the presence of bulk shear elasticity.

  1. arXiv Bench Measurements and Simulations of Beam Coupling Impedance

    CERN Document Server

    Niedermayer, Uwe

    After a general introduction, the basic principles of wake-field and beamcoupling- impedance computations are explained. This includes time domain, frequency domain, and methods that do not include excitations by means of a particle beam. The second part of this paper deals with radio frequency bench measurements of beam coupling impedances. The general procedure of the wire measurement is explained, and its features and limitations are discussed.

  2. Transvers Impedance Measurements of the Modified DARHT-2 Accelerator Cell Design

    International Nuclear Information System (INIS)

    Briggs, Dick; Waldron, Will

    2005-01-01

    The DARHT-2 accelerator cells have been redesigned to make their high voltage performance more robust. At the outset of the DARHT-2 development program about 8 years ago, an extensive campaign was mounted to minimize the transverse impedance of the original cell design. Since the initial spec on the machine was a beam current of 4 kA, the control of beam-breakup (BBU) amplification with a 2 microsecond pulse length was considered to be one the most critical issues in the design. Even after advances in detector technology allowed the beam current requirement to be lowered to 2 kA, the goal for the standard cell impedance was kept at ∼300 ohms/meter to allow for the possibility of future beam current upgrades to 4 kA without any modifications in the cells. The results of this campaign to minimize the transverse impedance are described in detail in Reference 1. After several iterations in the design of ferrite dampers and the anode finger stock shape, the measured (peak) impedance of the original standard cell was determined to be about 280 ohms/meter. (As a reference point, the measured impedance of the DARHT-1 cell is about 880 ohms/meter). This impedance provided such a wide safety margin against BBU amplification at 2 kA that it was felt that the cell redesign could focus on voltage holding without any detailed considerations of impacts on the transverse impedance. Now that a baseline design for the DARHT-2 cell has been established and tested, however, it was felt that a measurement of its impedance would be prudent. The results of these impedance measurements are presented in this note. The objective was mainly to do a ''quick check'' to ensure that there were no surprises, and to provide an estimate of the BBU frequencies and growth rates to the experimental test program

  3. Assessment of bolus transit with intraluminal impedance measurement in patients with esophageal motility disorders.

    Science.gov (United States)

    Bogte, A; Bredenoord, A J; Oors, J; Siersema, P D; Smout, A J P M

    2015-10-01

    The clinical management of patients with non-obstructive dysphagia is notoriously difficult. Esophageal impedance measurement can be used to measure esophageal bolus transit without the use of radiation exposure to patients. However, validation of measurement of bolus transit with impedance monitoring has only been performed in healthy subjects with normal motility and not in patients with dysphagia and esophageal motility disorders. The aim was, therefore, to investigate the relationship between transit of swallowed liquid boluses in healthy controls and in patients with dysphagia. Twenty healthy volunteers and 20 patients with dysphagia underwent concurrent impedance measurement and videofluoroscopy. Each subject swallowed five liquid barium boluses. The ability of detecting complete or incomplete bolus transit by means of impedance measurement was assessed, using radiographic bolus transit as the gold standard. Impedance monitoring recognized stasis and transit in 80.5% of the events correctly, with 83.9% of bolus transit being recognized and 77.2% of stasis being recognized correctly. In controls 79.8% of all swallows were scored correctly, whereas in patients 81.3% of all swallows were scored correctly. Depending on the contractility pattern, between 77.0% and 94.3% of the swallows were scored correctly. Impedance measurement can be used to assess bolus clearance patterns in healthy subjects, but can also be used to reliably assess bolus transit in patients with dysphagia and motility disorders. © 2015 John Wiley & Sons Ltd.

  4. A novel method for real-time skin impedance measurement during radiofrequency skin tightening treatments.

    Science.gov (United States)

    Harth, Yoram; Lischinsky, Daniel

    2011-03-01

    The thermal effects of monopolar and bipolar radiofrequency (RF) have been proven to be beneficial in skin tightening. Nevertheless, these effects were frequently partial or unpredictable because of the uncontrolled nature of monopolar or unipolar RF and the superficial nature of energy flow for bipolar or tripolar configurations. One of the hypotheses for lack or predictability of efficacy of the first-generation RF therapy skin tightening systems is lack of adaptation of delivered power to differences in individual skin impedance. A novel multisource phase-controlled system was used (1 MHz, power range 0-65 W) for treatment and real-time skin impedance measurements in 24 patients (EndyMed PRO™; EndyMed, Cesarea, Israel). This system allows continuous real-time measurement of skin impedance delivering constant energy to the patient skin independent of changes in its impedance. More than 6000 unique skin impedance measurements on 22 patients showed an average session impedance range was 215-584 Ohm with an average of 369 Ohm (standard deviation of 49 Ohm). Analyzing individual pulses (total of 600 readings) showed a significant decrease in impedance during the pulse. These findings validate the expected differences in skin impedance between individual patients and in the same patients during the treatment pulse. Clinical study on 30 patients with facial skin aging using the device has shown high predictability of efficacy (86.7% of patients had good results or better at 3 months' follow-up [decrease of 2 or more grades in Fitzpatrick's wrinkle scale]). The real-time customization of energy according to skin impedance allows a significantly more accurate and safe method of nonablative skin tightening with more consistent and predictable results. © 2011 Wiley Periodicals, Inc.

  5. Vascular measurements correlate with estrogen receptor status

    International Nuclear Information System (INIS)

    Lloyd, Mark C; Alfarouk, Khalid O; Verduzco, Daniel; Bui, Marilyn M; Gillies, Robert J; Ibrahim, Muntaser E; Brown, Joel S; Gatenby, Robert A

    2014-01-01

    Breast carcinoma can be classified as either Estrogen Receptor (ER) positive or negative by immunohistochemical phenotyping, although ER expression may vary from 1 to 100% of malignant cells within an ER + tumor. This is similar to genetic variability observed in other tumor types and is generally viewed as a consequence of intratumoral evolution driven by random genetic mutations. Here we view cellular evolution within tumors as a classical Darwinian system in which variations in molecular properties represent predictable adaptations to spatially heterogeneous environmental selection forces. We hypothesize that ER expression is a successful adaptive strategy only if estrogen is present in the microenvironment. Since the dominant source of estrogen is blood flow, we hypothesized that, in general, intratumoral regions with higher blood flow would contain larger numbers of ER + cells when compared to areas of low blood flow and in turn necrosis. This study used digital pathology whole slide image acquisition and advanced image analysis algorithms. We examined the spatial distribution of ER + and ER- cells, vascular density, vessel area, and tissue necrosis within histological sections of 24 breast cancer specimens. These data were correlated with the patients ER status and molecular pathology report findings. ANOVA analyses revealed a strong correlation between vascular area and ER expression and between high fractional necrosis and absent ER expression (R 2 = 39%; p < 0.003 and R 2 = 46%; p < 0.001), respectively). ER expression did not correlate with tumor grade or size. We conclude that ER expression can be understood as a Darwinian process and linked to variations in estrogen delivery by temporal and spatial heterogeneity in blood flow. This correlation suggests strategies to promote intratumoral blood flow or a cyclic introduction of estrogen in the treatment schedule could be explored as a counter-intuitive approach to increase the efficacy of anti

  6. Static and Dynamic Measurement of Dopamine Adsorption in Carbon Fiber Microelectrodes Using Electrochemical Impedance Spectroscopy.

    Science.gov (United States)

    Rivera-Serrano, Nilka; Pagan, Miraida; Colón-Rodríguez, Joanisse; Fuster, Christian; Vélez, Román; Almodovar-Faria, Jose; Jiménez-Rivera, Carlos; Cunci, Lisandro

    2018-02-06

    In this study, electrochemical impedance spectroscopy was used for the first time to study the adsorption of dopamine in carbon fiber microelectrodes. In order to show a proof-of-concept, static and dynamic measurements were taken at potentials ranging from -0.4 to 0.8 V versus Ag|AgCl to demonstrate the versatility of this technique to study dopamine without the need of its oxidation. We used electrochemical impedance spectroscopy and single frequency electrochemical impedance to measure different concentrations of dopamine as low as 1 nM. Moreover, the capacitance of the microelectrodes surface was found to decrease due to dopamine adsorption, which is dependent on its concentration. The effect of dissolved oxygen and electrochemical oxidation of the surface in the detection of dopamine was also studied. Nonoxidized and oxidized carbon fiber microelectrodes were prepared and characterized by optical microscopy, scanning electron microscopy, cyclic voltammetry, and electrochemical impedance spectroscopy. Optimum working parameters of the electrodes, such as frequency and voltage, were obtained for better measurement. Electrochemical impedance of dopamine was determined at different concentration, voltages, and frequencies. Finally, dynamic experiments were conducted using a flow cell and single frequency impedance in order to study continuous and real-time measurements of dopamine.

  7. Drilling electrode for real-time measurement of electrical impedance in bone tissues.

    Science.gov (United States)

    Dai, Yu; Xue, Yuan; Zhang, Jianxun

    2014-03-01

    In order to prevent possible damages to soft tissues, reliable monitoring methods are required to provide valuable information on the condition of the bone being cut. This paper describes the design of an electrical impedance sensing drill developed to estimate the relative position between the drill and the bone being drilled. The two-electrode method is applied to continuously measure the electrical impedance during a drill feeding movement: two copper wire brushes are used to conduct electricity in the rotating drill and then the drill is one electrode; a needle is inserted into the soft tissues adjacent to the bone being drilled and acts as another electrode. Considering that the recorded electrical impedance is correlated with the insertion depth of the drill, we theoretically calculate the electrode-tissue contact impedance and prove that the rate of impedance change varies considerably when the drill bit crosses the boundary between two different bone tissues. Therefore, the rate of impedance change is used to determine whether the tip of the drill is located in one of cortical bone, cancellous bone, and cortical bone near a boundary with soft tissue. In vitro experiments in porcine thoracic spines were performed to demonstrate the feasibility of the impedance sensing drill. The experimental results indicate that the drill, used with the proposed data-processing method, can provide accurate and reliable breakthrough detection in the bone-drilling process.

  8. Impedance computations and beam-based measurements: A problem of discrepancy

    Science.gov (United States)

    Smaluk, Victor

    2018-04-01

    High intensity of particle beams is crucial for high-performance operation of modern electron-positron storage rings, both colliders and light sources. The beam intensity is limited by the interaction of the beam with self-induced electromagnetic fields (wake fields) proportional to the vacuum chamber impedance. For a new accelerator project, the total broadband impedance is computed by element-wise wake-field simulations using computer codes. For a machine in operation, the impedance can be measured experimentally using beam-based techniques. In this article, a comparative analysis of impedance computations and beam-based measurements is presented for 15 electron-positron storage rings. The measured data and the predictions based on the computed impedance budgets show a significant discrepancy. Three possible reasons for the discrepancy are discussed: interference of the wake fields excited by a beam in adjacent components of the vacuum chamber, effect of computation mesh size, and effect of insufficient bandwidth of the computed impedance.

  9. Positive phase error from parallel conductance in tetrapolar bio-impedance measurements and its compensation

    Directory of Open Access Journals (Sweden)

    Ivan M Roitt

    2010-01-01

    Full Text Available Bioimpedance measurements are of great use and can provide considerable insight into biological processes.  However, there are a number of possible sources of measurement error that must be considered.  The most dominant source of error is found in bipolar measurements where electrode polarisation effects are superimposed on the true impedance of the sample.  Even with the tetrapolar approach that is commonly used to circumvent this issue, other errors can persist. Here we characterise the positive phase and rise in impedance magnitude with frequency that can result from the presence of any parallel conductive pathways in the measurement set-up.  It is shown that fitting experimental data to an equivalent electrical circuit model allows for accurate determination of the true sample impedance as validated through finite element modelling (FEM of the measurement chamber.  Finally, the model is used to extract dispersion information from cell cultures to characterise their growth.

  10. Measurement of void fraction distribution in two-phase flow by impedance CT with neural network

    International Nuclear Information System (INIS)

    Hayashi, Hideaki; Sumida, Isao; Sakai, Sinji; Wakai, Kazunori

    1996-01-01

    This paper describes a new method for measurement of void distribution using impedance CT with a hierarchical neural network. The present method consists of four processes. First, output electric currents are calculated by simulation of various distributions of void fraction. The relationship between distribution of void fraction and electric current is called 'teaching data'. Second, the neural network learns the teaching data by the back propagation method. Third, output electric currents are measured about actual two-phase flow. Finally, distribution of void fraction is calculated by the taught neural network using the measured electric currents. In this paper, measurement and learning parameters are adjusted, experimental results obtained using the impedance CT method are compared with data obtained by the impedance probe method. The results show that our method is effective for measurement of void fraction distribution. (author)

  11. Skin Impedance Measurements for Acupuncture Research: Development of a Continuous Recording System

    Directory of Open Access Journals (Sweden)

    Agatha P. Colbert

    2008-01-01

    Full Text Available Skin impedance at acupuncture points (APs has been used as a diagnostic/therapeutic aid for more than 50 years. Currently, researchers are evaluating the electrophysiologic properties of APs as a possible means of understanding acupuncture's mechanism. To comprehensively assess the diagnostic, therapeutic and mechanistic implications of acupuncture point skin impedance, a device capable of reliably recording impedances from 100 kΩ to 50 MΩ at multiple APs over extended time periods is needed. This article describes design considerations, development and testing of a single channel skin impedance system (hardware, control software and customized electrodes. The system was tested for accuracy against known resistors and capacitors. Two electrodes (the AMI and the ORI were compared for reliability of recording over 30 min. Two APs (LU 9 and PC 6 and a nearby non-AP site were measured simultaneously in four individuals for 60 min. Our measurement system performed accurately (within 5% against known resistors (580 kΩ–10 MΩ and capacitors (10 nF–150 nF. Both the AMI electrode and the modified ORI electrode recorded skin impedance reliably on the volar surface of the forearm (r = 0.87 and r = 0.79, respectively. In four of four volunteers tested, skin impedance at LU 9 was less than at the nearby non-AP site. In three of four volunteers skin impedance was less at PC 6 than at the nearby non-AP site. We conclude that our system is a suitable device upon which we can develop a fully automated multi-channel device capable of recording skin impedance at multiple APs simultaneously over 24 h.

  12. Portable bioimpedance monitor evaluation for continuous impedance measurements. Towards wearable plethysmography applications.

    Science.gov (United States)

    Ferreira, J; Seoane, F; Lindecrantz, K

    2013-01-01

    Personalised Health Systems (PHS) that could benefit the life quality of the patients as well as decreasing the health care costs for society among other factors are arisen. The purpose of this paper is to study the capabilities of the System-on-Chip Impedance Network Analyser AD5933 performing high speed single frequency continuous bioimpedance measurements. From a theoretical analysis, the minimum continuous impedance estimation time was determined, and the AD5933 with a custom 4-Electrode Analog Front-End (AFE) was used to experimentally determine the maximum continuous impedance estimation frequency as well as the system impedance estimation error when measuring a 2R1C electrical circuit model. Transthoracic Electrical Bioimpedance (TEB) measurements in a healthy subject were obtained using 3M gel electrodes in a tetrapolar lateral spot electrode configuration. The obtained TEB raw signal was filtered in MATLAB to obtain the respiration and cardiogenic signals, and from the cardiogenic signal the impedance derivative signal (dZ/dt) was also calculated. The results have shown that the maximum continuous impedance estimation rate was approximately 550 measurements per second with a magnitude estimation error below 1% on 2R1C-parallel bridge measurements. The displayed respiration and cardiac signals exhibited good performance, and they could be used to obtain valuable information in some plethysmography monitoring applications. The obtained results suggest that the AD5933-based monitor could be used for the implementation of a portable and wearable Bioimpedance plethysmograph that could be used in applications such as Impedance Cardiography. These results combined with the research done in functional garments and textile electrodes might enable the implementation of PHS applications in a relatively short time from now.

  13. Software development with two port calibration techniques for RHIC impedance measurements

    International Nuclear Information System (INIS)

    Mane, V.; Shea, T.

    1993-01-01

    The coupling impedance of accelerator devices is measured by simulating the beam with a central wire and measuring the scattering parameters of the system. The wire pipe system forms a mismatch with the 50 ohm transmission line. An integrated software environment has been developed in LabVIEW, for the Macintosh. The program measures the scattering parameters of some known standards, determines the connect scattering parameters of a device using TRL calibration technique and gives the impedance of the device. Its performance has been tested for some known microwave devices

  14. Polynomial Collocation for Handling an Inaccurately Known Measurement Configuration in Electrical Impedance Tomography

    DEFF Research Database (Denmark)

    Hyvönen, Niina; Kaarnioja, V.; Mustonen, L.

    2017-01-01

    The objective of electrical impedance tomography is to reconstruct the internal conductivity of a physical body based on measurements of current and potential at a finite number of electrodes attached to its boundary. Although the conductivity is the quantity of main interest in impedance...... tomography, a real-world measurement configuration includes other unknown parameters as well: The information on the contact resistances, electrode positions, and body shape is almost always incomplete. In this work, the dependence of the electrode measurements on all aforementioned model properties...

  15. Polymer microchip impedance spectroscopy through two parallel planar embedded microelectrodes: Understanding the impedance contribution of the surrounding polymer on the measurement accuracy

    International Nuclear Information System (INIS)

    Kechadi, Mohammed; Gamby, Jean; Chaal, Lila; Girault, Hubert; Saidani, Boualem; Tribollet, Bernard

    2013-01-01

    The present work describes a new methodology for contact free impedance of a solution in a polymer microchip taking into account the role played by the surrounding polymer on the impedance accuracy. Measurements were carried out using a photoablated polyethylene terephthalate (PET) microchannel above two embedded microband electrodes. The impedance diagrams exhibit a loop from high frequencies to medium frequencies (1 MHz–100 Hz) and a capacitive behavior at low frequencies (100–1 Hz). The impedance diagrams were corrected by eliminating from the global microchip response the contribution of the impedance of the PET layer between the two microband electrodes. This operation enables a clear observation of the impedance in the microchannel solution, including the bulk solution contribution and the interfacial capacitance related to the surface roughness of the photoablated microchannel. Models for the impedance of solutions of varying conductivity showed that the capacitance of the polymer–solution interface can be modeled by a constant phase element (CPE) with an exponent of 0.5. The loop diameter was found to be proportional to the microchannel resistivity, allowing a cell constant around 4.93 × 10 5 m −1 in contactless microelectrodes configuration

  16. Review of Stratum Corneum Impedance Measurement in Non-Invasive Penetration Application

    Directory of Open Access Journals (Sweden)

    Fei Lu

    2018-03-01

    Full Text Available Due to advances in telemedicine, mobile medical care, wearable health monitoring, and electronic skin, great efforts have been directed to non-invasive monitoring and treatment of disease. These processes generally involve disease detection from interstitial fluid (ISF instead of blood, and transdermal drug delivery. However, the quantitative extraction of ISF and the level of drug absorption are greatly affected by the individual’s skin permeability, which is closely related to the properties of the stratum corneum (SC. Therefore, measurement of SC impedance has been proposed as an appropriate way for assessing individual skin differences. In order to figure out the current status and research direction of human SC impedance detection, investigations regarding skin impedance measurement have been reviewed in this paper. Future directions are concluded after a review of impedance models, electrodes, measurement methods and systems, and their applications in treatment. It is believed that a well-matched skin impedance model and measurement method will be established for clinical and point-of care applications in the near future.

  17. Evaluation of the CERN Super Proton Synchrotron longitudinal impedance from measurements of the quadrupole frequency shift

    Directory of Open Access Journals (Sweden)

    A. Lasheen

    2017-06-01

    Full Text Available Longitudinal instabilities are one of the main limitations in the CERN Super Proton Synchrotron (SPS to reach the beam parameters required for the High Luminosity LHC project. In preparation to the SPS upgrade, possible remedies are studied by performing macroparticle simulations using the machine impedance model obtained from electromagnetic simulations and measurements. To benchmark the impedance model, the results of simulations are compared with various beam measurements. In this study, the reactive part of the impedance was probed by measuring the quadrupole frequency shift with intensity, obtained from bunch length oscillations at mismatched injection into the SPS. This method was applied over many last years to follow up the evolution of the SPS impedance, injecting bunches with the same bunch length. A novel approach, giving significantly more information, consists in varying the injected bunch length. The comparison of these measurements with macroparticle simulations allowed us to test the existing model, identify some missing SPS impedance and to obtain its possible dependence on frequency.

  18. New equivalent-electrical circuit model and a practical measurement method for human body impedance.

    Science.gov (United States)

    Chinen, Koyu; Kinjo, Ichiko; Zamami, Aki; Irei, Kotoyo; Nagayama, Kanako

    2015-01-01

    Human body impedance analysis is an effective tool to extract electrical information from tissues in the human body. This paper presents a new measurement method of impedance using armpit electrode and a new equivalent circuit model for the human body. The lowest impedance was measured by using an LCR meter and six electrodes including armpit electrodes. The electrical equivalent circuit model for the cell consists of resistance R and capacitance C. The R represents electrical resistance of the liquid of the inside and outside of the cell, and the C represents high frequency conductance of the cell membrane. We propose an equivalent circuit model which consists of five parallel high frequency-passing CR circuits. The proposed equivalent circuit represents alpha distribution in the impedance measured at a lower frequency range due to ion current of the outside of the cell, and beta distribution at a high frequency range due to the cell membrane and the liquid inside cell. The calculated values by using the proposed equivalent circuit model were consistent with the measured values for the human body impedance.

  19. Impedance Based Vitamin D Measurement Sensor and Algorithm for Human Wellness

    Directory of Open Access Journals (Sweden)

    Hyung Jin KIM

    2017-10-01

    Full Text Available While entering the modern society, medical technology has been able to cure almost all kinds of diseases. However, autoimmune diseases are increasing rapidly due to environment, food, and indoor life. In particular, vitamin D is lacking in about 90 % of Koreans. As a result of this, many middle-aged and older women are taking calcium, but most of them do not know their vitamin D levels. Based on this background, the goal of this paper is to develop a vitamin D measurement technique using a quantum analyzer that is capable of measuring various kinds of vitamins and minerals, and to prepare a plan to easily measure vitamin D by attaching it to a UVB device that is currently used in the hospital. The quantum analyzer was designed based on the impedance principle, and the impedance change according to vitamin D concentration was able to confirm a significant proportional relationship between vitamin D and impedance. In addition, the correlation between vitamin D and impedance was confirmed by in vitro experiment using lab mice, and the measurement error of the impedance meter for vitamin D concentration in the blood was confirmed to be about 12.7 %.

  20. Inductance analyzer based on auto-balanced circuit for precision measurement of fluxgate impedance

    Science.gov (United States)

    Setiadi, Rahmondia N.; Schilling, Meinhard

    2018-05-01

    An instrument for fluxgate sensor impedance measurement based on an auto-balanced circuit has been designed and characterized. The circuit design is adjusted to comply with the fluxgate sensor characteristics which are low impedance and highly saturable core with very high permeability. The system utilizes a NI-DAQ card and LabVIEW to process the signal acquisition and evaluation. Some fixed reference resistances are employed for system calibration using linear regression. A multimeter HP 34401A and impedance analyzer Agilent 4294A are used as calibrator and validator for the resistance and inductance measurements. Here, we realized a fluxgate analyzer instrument based on auto-balanced circuit, which measures the resistance and inductance of the device under test with a small error and much lower excitation current to avoid core saturation compared to the used calibrator.

  1. The development of the miniaturized waveform receiver with the function measuring Antenna Impedance in space plasmas

    Science.gov (United States)

    Ishii, H.; Kojima, H.; Fukuhara, H.; Okada, S.; Yamakawa, H.

    2012-04-01

    Plasma wave is one of the most essential physical quantities in the solar terrestrial physics. The role of plasma wave receiver onboard satellites is to detect plasma waves in space with a good signal to noise ratio. There are two types of plasma wave receivers, the sweep frequency analyzer and the waveform capture. While the sweep frequency analyzer provides plasma wave spectra, the waveform capture obtains waveforms with phase information that is significant in studying nonlinear phenomena. Antenna sensors to observe electric fields of the plasma waves show different features in plasmas from in vacuum. The antenna impedances have specific characteristics in the frequency domain because of the dispersion of plasmas. These antenna impedances are expressed with complex number. We need to know not only the antenna impedances but also the transfer functions of plasma wave receiver's circuits in order to calibrate observed waveforms precisely. The impedances of the electric field antennas are affected by a state of surrounding plasmas. Since satellites run through various regions with different plasma parameters, we precisely should measure the antenna impedances onboard spacecraft. On the contrary, we can obtain the plasma density and by measuring the antenna impedances. Several formulas of the antenna impedance measurement system were proposed. A synchronous detection method is used on the BepiColombo Mercury Magnetospheric Orbiter (MMO), which will be launched in 2014. The digital data are stored in the onboard memory. They are read out and converted to the analog waveforms by D/A converter. They are fed into the input of the preamplifiers of antenna sensors through a resistor. We can calculate a transfer function of the circuit by applying the synchronous detection method to the output waveform from waveform receivers and digital data as a signal source. The size of this system is same as an A5 board. In recent years, Application Specific Integrated Circuit (ASIC

  2. Studies of longitudinal profile of electron bunches and impedance measurements at Indus-2 synchrotron radiation source

    Energy Technology Data Exchange (ETDEWEB)

    Garg, Akash Deep, E-mail: akash-deep@rrcat.gov.in [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India); Homi Bhabha National Institute (HBNI) at Raja Ramanna Centre for Advanced Technology, Indore (India); Yadav, S.; Kumar, Mukesh; Shrivastava, B.B.; Karnewar, A.K.; Ojha, A.; Puntambekar, T.A. [Beam Diagnostics Section (BDS), Indus Operations, Beam Dynamics and Diagnostics Division (IOBDD), Raja Ramanna Centre for Advanced Technology, Indore 452 013, M.P. (India)

    2016-04-01

    Indus-2 is a 3rd generation synchrotron radiation source at the Raja Ramanna Centre for Advanced Technology (RRCAT) in India. We study the longitudinal profile of electrons in Indus-2 by using dual sweep synchroscan streak camera at visible diagnostic beamline. In this paper, the longitudinal profiles of electron bunch are analyzed by filling beam current in a single bunch mode. These studies are carried at injection energy (550 MeV) and at ramped beam energy (2.5 GeV). The effects of the wakefield generated interactions between the circulating electrons and the surrounding vacuum chamber are analyzed in terms of measured effects on longitudinal beam distribution. The impedance of the storage ring is obtained by fitting the solutions of Haissinski equation to the measured bunch lengthening with different impedance models. The impedance of storage ring obtained by a series R+L impedance model indicates a resistance (R) of 1350±125 Ω, an inductance (L) of 180±25 nH and broadband impedance of 2.69 Ω. These results are also compared with the values obtained from measured synchronous phase advancing and scaling laws. These studies are very useful in better understanding and control of the electromagnetic interactions.

  3. Measurement of bio-impedance with a smart needle to confirm percutaneous kidney access.

    Science.gov (United States)

    Hernandez, D J; Sinkov, V A; Roberts, W W; Allaf, M E; Patriciu, A; Jarrett, T W; Kavoussi, L R; Stoianovici, D

    2001-10-01

    The traditional method of percutaneous renal access requires freehand needle placement guided by C-arm fluoroscopy, ultrasonography, or computerized tomography. This approach provides limited objective means for verifying successful access. We developed an impedance based percutaneous Smart Needle system and successfully used it to confirm collecting system access in ex vivo porcine kidneys. The Smart Needle consists of a modified 18 gauge percutaneous access needle with the inner stylet electrically insulated from the outer sheath. Impedance is measured between the exposed stylet tip and sheath using Model 4275 LCR meter (Hewlett-Packard, Sunnyvale, California). An ex vivo porcine kidney was distended by continuous gravity infusion of 100 cm. water saline from a catheter passed through the parenchyma into the collecting system. The Smart Needle was gradually inserted into the kidney to measure depth precisely using a robotic needle placement system, while impedance was measured continuously. The Smart Needle was inserted 4 times in each of 4 kidneys. When the needle penetrated the distended collecting system in 11 of 16 attempts, a characteristic sharp drop in resistivity was noted from 1.9 to 1.1 ohm m. Entry into the collecting system was confirmed by removing the stylet and observing fluid flow from the sheath. This characteristic impedance change was observed only at successful entry into the collecting system. A characteristic sharp drop in impedance signifies successful entry into the collecting system. The Smart Needle system may prove useful for percutaneous kidney access.

  4. MEASUREMENT OF HIGH Q RF CAVITY IMPEDANCE WITH BEAM

    International Nuclear Information System (INIS)

    Limborg, Cecile

    2003-01-01

    An inexpensive method to measure, with beam, the Rs and Q of narrow-band high order resonances in RF cavities was developed on SPEAR. The two main results of this study are: (1) an improved operational stability of SPEAR; and (2) the decision to keep the present cavities for the proposed SPEAR upgrade. SPEAR3 will be run initially at 200 mA, twice the present current. Just beyond the current threshold, and before step loss, there is a regime in which the beam performs large amplitude, low frequency oscillations. Detailed measurements were performed to characterize the frequency, amplitude, growth and damping time of these relaxation oscillations

  5. Measurements on the SPS 200 MHz Travelling Wave Cavity towards an Impedance Model

    CERN Document Server

    Roggen, Toon; Caspers, Fritz; Vollinger, Christine; CERN. Geneva. ATS Department

    2016-01-01

    This note discusses the contribution of the SPS 200 MHz TWC (Travelling Wave Cavity) to the SPS longitudinal impedance model. The measurement method and setup is briefly explained and a comparison with simulations is discussed for both the fundamental pass band (FPB) as well as the Higher Order Modes (HOMs). In addition a number of improvements to the measurement setup are discussed.

  6. Vertical impedance measurements on concrete bridge decks for assessing susceptibility of reinforcing steel to corrosion

    Science.gov (United States)

    Bartholomew, Paul D.; Guthrie, W. Spencer; Mazzeo, Brian A.

    2012-08-01

    Corrosion is a pressing problem for aging concrete infrastructure, especially bridge decks. Because of its sensitivity to factors that affect corrosion of reinforcing steel in concrete, resistivity is an important structural health indicator for reinforced concrete structures. In this research, an instrument was developed to measure vertical impedance on concrete bridge decks. Measurements of vertical impedance on slabs prepared in the laboratory, on slabs removed from decommissioned bridge decks, and on an in-service bridge deck in the field demonstrate the utility of the new apparatus.

  7. An experimental applications of impedance measurements by spectral analysis to electrochemistry and corrosion

    International Nuclear Information System (INIS)

    Castro, E.B.; Vilche, J.R.; Milocco, R.H.

    1984-01-01

    An impedance measurement system based on the spectral analysis of excitation and response signals was implemented using a pseudo-random binary sequence in the generation of the electrical perturbation signal. The spectral density functions were estimated through finite Fourier transforms of the original time history records by fast computation of Fourier series. Experimental results obtained using the FFT algorithm in the developed impedance measurement system which covers a wide frequency range, 10 KHz >= f >= 1 mHz, are given both for dummy cells representing conventional electric circuits in electrochemistry and corrosion systems and for the Fe/acidic chloride solution interfaces under different polarization conditions. (C.L.B.) [pt

  8. In-Plane Impedance Spectroscopy measurements in Vanadium Dioxide thin films

    Science.gov (United States)

    Ramirez, Juan; Patino, Edgar; Schmidt, Rainer; Sharoni, Amos; Gomez, Maria; Schuller, Ivan

    2012-02-01

    In plane Impedance Spectroscopy measurements have been done in Vanadium Dioxide thin films in the range of 100 Hz to 1 MHz. Our measurements allows distinguishing between the resistive and capacitive response of the Vanadium Dioxide films across the metal-insulator transition. A non ideal RC behavior was found in our thin films from room temperature up to 334 K. Around the MIT, an increase of the total capacitance is observed. A capacitor-network model is able to reproduce the capacitance changes across the MIT. Above the MIT, the system behaves like a metal as expected, and a modified equivalent circuit is necessary to describe the impedance data adequately.

  9. UNIVERSAL AUTO-CALIBRATION FOR A RAPID BATTERY IMPEDANCE SPECTRUM MEASUREMENT DEVICE

    Energy Technology Data Exchange (ETDEWEB)

    Jon P. Christophersen; John L. Morrison; William H. Morrison

    2014-03-01

    Electrochemical impedance spectroscopy has been shown to be a valuable tool for diagnostics and prognostics of energy storage devices such as batteries and ultra-capacitors. Although measurements have been typically confined to laboratory environments, rapid impedance spectrum measurement techniques have been developed for on-line, embedded applications as well. The prototype hardware for the rapid technique has been validated using lithium-ion batteries, but issues with calibration had also been identified. A new, universal automatic calibration technique was developed to address the identified issues while also enabling a more simplified approach. A single, broad-frequency range is used to calibrate the system and then scaled to the actual range and conditions used when measuring a device under test. The range used for calibration must be broad relative to the expected measurement conditions for the scaling to be successful. Validation studies were performed by comparing the universal calibration approach with data acquired from targeted calibration ranges based on the expected range of performance for the device under test. First, a mid-level shunt range was used for calibration and used to measure devices with lower and higher impedance. Next, a high excitation current level was used for calibration, followed by measurements using lower currents. Finally, calibration was performed over a wide frequency range and used to measure test articles with a lower set of frequencies. In all cases, the universal calibration approach compared very well with results acquired following a targeted calibration. Additionally, the shunts used for the automated calibration technique were successfully characterized such that the rapid impedance measurements compare very well with laboratory-scale measurements. These data indicate that the universal approach can be successfully used for onboard rapid impedance spectra measurements for a broad set of test devices and range of

  10. Piezo-sensor self-diagnostics using electrical impedance measurements.

    Energy Technology Data Exchange (ETDEWEB)

    Park, G. H. (Gyu Hae); Farrar, C. R. (Charles R.); Rutherford, A. C. (Amanda C.); Robertson, A. N. (Amy N.)

    2004-01-01

    This paper present the piezoelectric sensor self-diagnostic procedure that performs in-situ monitoring of the operational status of piezoelectric materials (PZT) used for sensors and actuators in structural health monitoring (SHM) applications. The use of active-sensing piezoelectric materials has received considerable attention in the SHM community. A critical aspect of the piezoelectric active-sensing technologies is that usually large numbers of distributed sensors and actuators are needed to perform the required monitoring process. The sensor/actuator self-diagnostic procedure, where the sensors/actuators are confirmed to be functioning properly during operation, is therefore a critical component to successfully complete the SHM process and to minimize the false indication regarding the structural health. The basis of this procedure is to track the changes in the capacitive value of piezoelectric materials resulting from the sensor failure, which is manifested in the imaginary part of the measured electrical admittances. Furthermore, through the analytical and experimental investigation, it is confirmed that the bonding layer between the PZT and a host structure significantly contributes to the measured capacitive values. Therefore, by monitoring the imaginary part of the admittances, one can quantitatively assess the degradation of the mechanical/electrical properties of the PZT and its attachment to a host structure. This paper concludes with an experimental example to demonstrate the feasibility of the proposed sensor-diagnostic procedure.

  11. Applicability of impedance measuring method to the detection of irradiation treatment of potatoes

    International Nuclear Information System (INIS)

    Hayashi, Toru; Todoriki, Setsuko; Otobe, Kazunori; Sugiyama, Junnichi

    1993-01-01

    The incubation condition of potato tubers prior to impedance measurement greatly influenced the reliability of detection of irradiated potatoes; the impedance ratio at 5 kHz to 50 kHz (Z 5k /Z 50k ) determined at 22degC at an apical region of tuber which was pre-incubated at 22degC for 3 days or longer resulted in the best detection of radiation treatment of potatoes. The impedance ratio was dependent upon dose applied to potato tubers. Potatoes irradiated at 100 Gy could be distinguished from unirradiated potatoes for 10 cultivars of potatoes. The impedance ratio of potatoes irradiated at the same dose was little influenced by the planting locality if the cultivar was the same, although the ratio varied with potato cultivars. These results indicate that irradiated potatoes can be detected if the potato cultivar is known. Potatoes 'Danshaku' commercially irradiated at the Shihiro Potato Irradiation Center could be differentiated from unirradiated 'Danshaku' at different planting localities; the impedance ratio was lower than 2.75 for the unirradiated potatoes and higher than 2.75 for the irradiated ones. (author)

  12. Electrode-Skin contact impedance: In vivo measurements on an ovine model

    International Nuclear Information System (INIS)

    Nguyen, D T; Kosobrodov, R; Jin, C; McEwan, A; Barry, M A; Chik, W; Thiagalingam, A; Oh, T I

    2013-01-01

    The problem of electrical impedance between the skin and the electrode is an on-going challenge in bio-electronics. This is particularly true in the case of Electrical Impedance Tomography (EIT), which uses a large number of skin-contact electrodes and is very sensitive to noise. In the present article, contact impedance is measured and compared for a range of electrodes placed on the thorax of an ovine model. The study has been approved by the Westmead Hospital Animal Ethics Committee. The electrode models that were employed in the research are Ag/AgCl electrodes (E1), commonly used for ECG and EIT measurements in both humans and animal models, stainless steel crocodile clips (E2), typically used on animal models, and novel multi-point dry electrodes in two modifications: bronze plated (E3) and nickel plated (E4). Further, since the contact impedance is mostly attributed to the acellular outer layer of the skin, in our experiment, we attempted to study the effect of this layer by comparing the results when the skin is intact and when electrodes are introduced underneath the skin through small cuts. This boundary effect was assessed by comparison of measurements obtained during E2 skin surface contact, and sub-cutaneous contact (E5). Twelve gauge intradermal needles were also tested as an electrode (E6). The full impedance spectrum, from 500 Hz to 300 kHz, was recorded, analysed and compared. As expected, the contact impedance in the more invasive cases, i.e the electrodes under the skin, is significantly lower than in the non-invasive cases. At the frequency of 50 kHz which is commonly used in lung EIT acquisition, electrodes E3, E4 and E6 demonstrated contact impedance of less than 200 Ω, compared to more than 400 Ω measured for electrodes E1, E2 and E5. In conclusion, the novel multipoint electrodes proved to be best suited for EIT purposes, because they are non-invasive and have lower contact impedance than Ag/AgCl and crocodile clips, in both invasive and

  13. Automated AC Electrical Impedance Measurement of Ceramic Oxides by means of a Lock-in Amplifier

    International Nuclear Information System (INIS)

    Al-Khawaja, S.; Al-Sous, M. B.; Nasrallah, F.

    2009-06-01

    In this study, the electrical impedance of some ceramic oxides has been investigated employing the Perkin Elmer DSP 7280 Lock-in amplifier, while recording the electric response versus frequency and temperature at constant amplitude. Via integral automation of this lock-in with other delicate electrical measuring devices, a control program has been developed to accurately and swiftly acquire the frequency response of the sample, in order to lately infer the resulting samples' impedance in volt and ampere. Two maxima peaks characterising the impedance, in the curve of the doped molybdenum oxide have been observed discerning two phases in the sample (doped with 40% of niobium oxide), which shows a remarkable relaxation related to improvement in its ionic conductivity within the solid phase, with respect to increasing frequency. (author)

  14. Development of high impedance measurement system for water leakage detection in implantable neuroprosthetic devices.

    Science.gov (United States)

    Yousif, Aziz; Kelly, Shawn K

    2016-08-01

    There has been a push for a greater number of channels in implantable neuroprosthetic devices; but, that number has largely been limited by current hermetic packaging technology. Microfabricated packaging is becoming reality, but a standard testing system is needed to prepare these devices for clinical trials. Impedance measurements of electrodes built into the packaging layers may give an early warning of device failure and predict device lifetime. Because the impedance magnitudes of such devices can be on the order of gigaohms, a versatile system was designed to accommodate ultra-high impedances and allow future integrated circuit implementation in current neural prosthetic technologies. Here we present the circuitry, control software, and preliminary testing results of our designed system.

  15. Impedance measurements and high-resolution manometry help to better define rumination episodes

    NARCIS (Netherlands)

    Kessing, Boudewijn F.; Govaert, Frank; Masclee, Ad A. M.; Conchillo, José M.

    2011-01-01

    Rumination syndrome is a disorder of unknown etiology characterized by regurgitation of recently ingested food. We aimed to improve the diagnosis of rumination syndrome by classification of separate rumination symptoms using (1) an ambulatory manometry/impedance (AMIM) measurement and (2) a

  16. Coaxial wire impedance measurements of BPM buttons for the PEP-II B- factory

    International Nuclear Information System (INIS)

    Corlett, J.N.

    1995-09-01

    The coaxial wire impedance measurement uses a conducting rod placed along the beam axis in the vacuum chamber, forming the center conductor in a coaxial line system. Tapers at either end of this section allow for smooth impedance transformation from the 50Ω lines used in common microwave measurement equipment, to the characteristic impedance of the vacuum chamber and center conductor, typically around 200Ω. RF and microwave absorptive material placed in the ends of the vacuum chamber and in the impedance matching tapers minimizes reflections which cause trapped modes within the apparatus, allowing measurements to be made above the traveling-wave cut-off frequency of the vacuum vessel (typically 2.5 - 3.0 GHz for PEP-II). A smooth vessel of the same cross-section as that containing the device under test is used in a reference measurement Resonances within the apparatus are difficult to avoid completely and require careful placing of absorptive material, manufacture of test and reference chambers, and assembly of apparatus

  17. Servo-controlled pneumatic pressure oscillator for respiratory impedance measurements and high-frequency ventilation.

    Science.gov (United States)

    Kaczka, David W; Lutchen, Kenneth R

    2004-04-01

    The ability to provide forced oscillatory excitation of the respiratory system can be useful in mechanical impedance measurements as well as high frequency ventilation (HFV). Experimental systems currently used for generating forced oscillations are limited in their ability to provide high amplitude flows or maintain the respiratory system at a constant mean pressure during excitation. This paper presents the design and implementation of a pneumatic pressure oscillator based on a proportional solenoid valve. The device is capable of providing forced oscillatory excitations to the respiratory system over a bandwidth suitable for mechanical impedance measurements and HVF. It delivers high amplitude flows (> 1.4 l/s) and utilizes a servo-control mechanism to maintain a load at a fixed mean pressure during simultaneous oscillation. Under open-loop conditions, the device exhibited a static hysteresis of approximately 7%, while its dynamic magnitude and phase responses were flat out to 10 Hz. Broad-band measurement of total harmonic distortion was approximately 19%. Under closed-loop conditions, the oscillator was able to maintain a mechanical test load at both positive and negative mean pressures during oscillatory excitations from 0.1 to 10.0 Hz. Impedance of the test load agreed closely with theoretical predictions. We conclude that this servo-controlled oscillator can be a useful tool for respiratory impedance measurements as well as HFV.

  18. Impedance measurements on Au microelectrodes using controlled atmosphere high temperature scanning probe microscope

    DEFF Research Database (Denmark)

    Wu, Yuehua; Hansen, Karin Vels; Jacobsen, Torben

    2011-01-01

    High temperature impedance measurements on Au microelectrodes deposited on polished yttria stabilized zirconia (YSZ) pellets were demonstrated using a newly designed controlled atmosphere high temperature scanning probe microscope (CAHT-SPM). Probes based on Pt0.8Ir0.2 were fabricated and employed...

  19. End-point impedance measurements across dominant and nondominant hands and robotic assistance with directional damping.

    Science.gov (United States)

    Erden, Mustafa Suphi; Billard, Aude

    2015-06-01

    The goal of this paper is to perform end-point impedance measurements across dominant and nondominant hands while doing airbrush painting and to use the results for developing a robotic assistance scheme. We study airbrush painting because it resembles in many ways manual welding, a standard industrial task. The experiments are performed with the 7 degrees of freedom KUKA lightweight robot arm. The robot is controlled in admittance using a force sensor attached at the end-point, so as to act as a free-mass and be passively guided by the human. For impedance measurements, a set of nine subjects perform 12 repetitions of airbrush painting, drawing a straight-line on a cartoon horizontally placed on a table, while passively moving the airbrush mounted on the robot's end-point. We measure hand impedance during the painting task by generating sudden and brief external forces with the robot. The results show that on average the dominant hand displays larger impedance than the nondominant in the directions perpendicular to the painting line. We find the most significant difference in the damping values in these directions. Based on this observation, we develop a "directional damping" scheme for robotic assistance and conduct a pilot study with 12 subjects to contrast airbrush painting with and without robotic assistance. Results show significant improvement in precision with both dominant and nondominant hands when using robotic assistance.

  20. Method and device for bio-impedance measurement with hard-tissue applications

    International Nuclear Information System (INIS)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-01-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kΩ to 10 MΩ across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kΩ to 10 MΩ and from 20 pF to 100 pF, are discussed

  1. Method and device for bio-impedance measurement with hard-tissue applications.

    Science.gov (United States)

    Guimerà, A; Calderón, E; Los, P; Christie, A M

    2008-06-01

    Bio-impedance measurements can be used to detect and monitor several properties of living hard-tissues, some of which include bone mineral density, bone fracture healing or dental caries detection. In this paper a simple method and hardware architecture for hard tissue bio-impedance measurement is proposed. The key design aspects of such architecture are discussed and a commercial handheld ac impedance device is presented that is fully certified to international medical standards. It includes a 4-channel multiplexer and is capable of measuring impedances from 10 kOmega to 10 MOmega across a frequency range of 100 Hz to 100 kHz with a maximum error of 5%. The device incorporates several user interface methods and a Bluetooth link for bi-directional wireless data transfer. Low-power design techniques have been implemented, ensuring the device exceeds 8 h of continuous use. Finally, bench test results using dummy cells consisting of parallel connected resistors and capacitors, from 10 kOmega to 10 MOmega and from 20 pF to 100 pF, are discussed.

  2. Simulations and measurements of coupling impedance for modern particle accelerator devices

    CERN Document Server

    AUTHOR|(CDS)2158523; Biancacci, Nicolò; Mostacci, Andrea

    In this document it has been treated the study of the coupling impedance in modern devices, already installed or not, in different particle accelerators. In the specific case: • For a device in-phase of project, several simulations for impedance calculation have been done. • For a component already realized and used, measurements of coupling impedance value have been done. Simulations are used to determine the impact of the interconnect between to magnets, designed for the future particle accelerator FCC, on the overall impedance of the machine which is about 100 km long. In particular has been done a check between theory, simulations and measurements of components already built, allowing a better and deeper study of the component we have analysed. Controls that probably will be helpful to have a clear guideline in future works. The measurements instead concern in an existing component that was already used in LHC, the longest particle accelerator ever realised on the planet, 27 km long. The coupling impe...

  3. Wireless guided wave and impedance measurement using laser and piezoelectric transducers

    International Nuclear Information System (INIS)

    Park, Hyun-Jun; Sohn, Hoon; Yun, Chung-Bang; Chung, Joseph; Lee, Michael M S

    2012-01-01

    Guided-wave- and impedance-based structural health monitoring (SHM) techniques have gained much attention due to their high sensitivity to small defects. One of the popular devices commonly used for guided wave and impedance measurements is a lead zirconate titanate (PZT) transducer. This study proposes a new wireless scheme where the power and data required for PZT excitation and sensing are transmitted via laser. First, a modulated laser beam is wirelessly transmitted to the photodiode connected to a PZT on a structure. Then, the photodiode converts the laser light into an electric signal, and it is applied to the PZT for excitation. The corresponding responses, impedance at the same PZT or guided waves at another PZT, are measured, re-converted into laser light, and wirelessly transmitted back to the other photodiode located in the data interrogator for signal processing. The feasibility of the proposed wireless guided wave and impedance measurement schemes has been examined through circuit analyses and experimentally investigated in a laboratory setup. (paper)

  4. The measurement of skin impedance for the diagnosis of skin cancer

    International Nuclear Information System (INIS)

    Menzies, S.; Crook, B.; McCarthy, W.

    1996-01-01

    Full text: In vivo skin impedance measurements have been reported to be diagnostic in differentiating benign from malignant skin tumours (Kiss G et al. Borgyogy Vener Szle 45: 164,1969; Melczer N. In: Cancer of the Skin. Saunders Co. Philadelphia, 1976, pp293-313). However, in contrast to non-melanoma skin cancer, only, a small sample of malignant melanomas were reported in these previous studies. We performed skin impedance measurements on a larger sample of melanomas in order to assess the potential use of such instrumentation for clinical diagnosis. The diagnostic method described by Kiss and Horvath was reproduced with only minor modifications. Low voltage impedance measurements at 1600 Hz were taken over each lesion and on nearby surrounding normal skin. Filter paper (4mm diameter) soaked in 0.1 M KCl was used at the skin-probe interface. A minimum of 2 skin and 1 lesion measurements were taken. All lesions were taken from relatively hairless sites and were non abraded or ulcerated. With the exception of 6 seborrhoeic keratoses all lesions were excised for histological diagnosis. The lesions tested were 27 invasive melanomas, 3 in situ melanomas, 27 basal cell carcinomas (BCC), 70 benign melanocytic lesions, 19 seborrhoeic keratoses, 5 Bowens disease (in situ SCC), 1 squamous cell carcinoma (SCC) and 25 other benign lesions. Results were interpreted as previously (Melczer) by the quotient of skin impedance / lesion impedance > 1.5 indicating malignancy. Analysis of total melanocytic lesions gave a sensitivity of 44% and specificity of 83% for the diagnosis of invasive melanoma (p < 0.05). Fifty two percent of BCCs were positively diagnosed. Analysis of all benign versus all invasive malignancy gave a sensitivity of 47% and specificity of 77% for the diagnosis of invasive malignancy (p < 0.01). While impedance measurements at 1600 Hz provide a statistically significant differentiation of melanoma versus non-melanoma and invasive malignancy versus benign lesions

  5. Impedance measurement of irradiated potatoes: a method to identify radiation processing

    International Nuclear Information System (INIS)

    Mastro, N.L. del; Villavicencio, A.L.C.H.

    1992-01-01

    The potato is firmly established in many parts of the world as a major staple food. Then, radiation processing of potato is approved in many countries for sprouting inhibition and extension of shelf life in a dose range from about 0.01 to 0.15 kGy of 60 Co. The use of electrical conductance methods for the detection of Salmonella, some virus or the action of herbicides on plant has been reported and differences have been observed between instruments in respect of the magnitude of conductance change or rates of change in conductance response. A reliable technique to identify potatoes or other food products has not been established so far, though several methods have been reported. Electrical impedance might thus serve for characterization of unirradiated and irradiated tissues and cells. In this work, potato tubers from an European variety, named Bintje, grown in Sao Paulo State were employed. Potatoes were punctured with steel electrodes and impedance measured at different frequencies (1 k Hz-100 k Hz) by passing 3-5 m A alternating current through it. The impedance ratio of 50 k Hz/5 k Hz calculated from ten replicate samples decreases with the increment of the dose when doses of O 0.75 and 0.15 kGy from a Gamma Cell 220 were utilized. The impedance measurement were slightly affected by the place of puncture. (author)

  6. A cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Pivnenko, Sergey; Zhang, Jiaying; Breinbjerg, Olav

    2010-01-01

    are represented in terms of spherical wave expansions (SWEs), and the propagation is accounted for by a transmission formula. In this paper the measurement results by the proposed technique will be presented for several AUTs, including a standard gain horn antenna, a monopole antenna, and an electrically small......Impedance and gain measurements for electrically small antennas represent a great challenge due to influences of the feeding cable. The leaking current along the cable and scattering effects are two main issues caused by the feed line. In this paper, a novel cable-free antenna impedance and gain...... measurement technique for electrically small antennas is proposed. The antenna properties are extracted by measuring the signal scattered by the antenna under test (AUT), when it is loaded with three known loads. The technique is based on a rigorous electromagnetic model where the probe and AUT...

  7. Relations of mitochondrial genetic variants to measures of vascular function.

    Science.gov (United States)

    Fetterman, Jessica L; Liu, Chunyu; Mitchell, Gary F; Vasan, Ramachandran S; Benjamin, Emelia J; Vita, Joseph A; Hamburg, Naomi M; Levy, Daniel

    2018-05-01

    Mitochondrial genetic variation with resultant alterations in oxidative phosphorylation may influence vascular function and contribute to cardiovascular disease susceptibility. We assessed relations of peptide-encoding variants in the mitochondrial genome with measures of vascular function in Framingham Heart Study participants. Of 258 variants assessed, 40 were predicted to have functional consequences by bioinformatics programs. A maternal pattern of heritability was estimated to contribute to the variability of aortic stiffness. A putative association with a microvascular function measure was identified that requires replication. The methods we have developed can be applied to assess the relations of mitochondrial genetic variation to other phenotypes. Copyright © 2017 Elsevier B.V. and Mitochondria Research Society. All rights reserved.

  8. Beam measurement of the high frequency impedance sources with long bunches in the CERN Super Proton Synchrotron

    Directory of Open Access Journals (Sweden)

    A. Lasheen

    2018-03-01

    Full Text Available Microwave instability in the Super Proton Synchrotron (SPS at CERN is one of the main limitations to reach the requirements for the High Luminosity-LHC project (increased beam intensity by a factor 2. To identify the impedance source responsible of the instability, beam measurements were carried out to probe the SPS impedance. The method presented in this paper relies on measurements of the unstable spectra of single bunches, injected in the SPS with the rf voltage switched off. The modulation of the bunch profile gives information about the main impedance sources driving microwave instability, and is compared to particle simulations using the SPS impedance model to identify the most important contributions. This allowed us to identify the vacuum flanges as the main impedance source for microwave instability in the SPS, and to evaluate possible missing impedance sources.

  9. Beam measurement of the high frequency impedance sources with long bunches in the CERN Super Proton Synchrotron

    Science.gov (United States)

    Lasheen, A.; Argyropoulos, T.; Bohl, T.; Esteban Müller, J. F.; Timko, H.; Shaposhnikova, E.

    2018-03-01

    Microwave instability in the Super Proton Synchrotron (SPS) at CERN is one of the main limitations to reach the requirements for the High Luminosity-LHC project (increased beam intensity by a factor 2). To identify the impedance source responsible of the instability, beam measurements were carried out to probe the SPS impedance. The method presented in this paper relies on measurements of the unstable spectra of single bunches, injected in the SPS with the rf voltage switched off. The modulation of the bunch profile gives information about the main impedance sources driving microwave instability, and is compared to particle simulations using the SPS impedance model to identify the most important contributions. This allowed us to identify the vacuum flanges as the main impedance source for microwave instability in the SPS, and to evaluate possible missing impedance sources.

  10. Abdominal fat thickness measurement using Focused Impedance Method (FIM) - phantom study

    Science.gov (United States)

    Haowlader, Salahuddin; Baig, Tanveer Noor; Siddique-e Rabbani, K.

    2010-04-01

    Abdominal fat thickness is a risk indicator of heart diseases, diabetes, etc., and its measurement is therefore important from the point of view of preventive care. Tetrapolar electrical impedance measurements (TPIM) could offer a simple and low cost alternative for such measurement compared to conventional techniques using CT scan and MRI, and has been tried by different groups. Focused Impedance Method (FIM) appears attractive as it can give localised information. An intuitive physical model was developed and experimental work was performed on a phantom designed to simulate abdominal subcutaneous fat layer in a body. TPIM measurements were performed with varying electrode separations. For small separations of current and potential electrodes, the measured impedance changed little, but started to decrease sharply beyond a certain separation, eventually diminishing gradually to negligible values. The finding could be explained using the intuitive physical model and gives an important practical information. TPIM and FIM may be useful for measurement of SFL thickness only if the electrode separations are within a certain specific range, and will fail to give reliable results if beyond this range. Further work, both analytical and experimental, are needed to establish this technique on a sound footing.

  11. Comparison between laboratory measurements, simulations, and analytical predictions of the transverse wall impedance at low frequencies

    CERN Document Server

    Roncarolo, F; Kroyer, T; Metral, E; Mounet, N; Salvant, B; Zotter, B

    2009-01-01

    The prediction of the transverse wall beam impedance at the first unstable betatron line (8 kHz) of the CERN Large Hadron Collider (LHC) is of paramount importance for understanding and controlling the related coupled-bunch instabilities. Until now only novel analytical formulas were available at this frequency. Recently, laboratory measurements and numerical simulations were performed to cross-check the analytical predictions. The experimental results based on the measurement of the variation of a probe coil inductance in the presence of (i) sample graphite plates, (ii) stand-alone LHC collimator jaws, and (iii) a full LHC collimator assembly are presented in detail. The measurement results are compared to both analytical theories and simulations. In addition, the consequences for the understanding of the LHC impedance are discussed.

  12. A compact wideband precision impedance measurement system based on digital auto-balancing bridge

    International Nuclear Information System (INIS)

    Hu, Binxin; Wang, Jinyu; Song, Guangdong; Zhang, Faxiang

    2016-01-01

    The ac impedance spectroscopy measurements are predominantly taken by using impedance analyzers based on analog auto-balancing bridge. However, those bench-top analyzers are generally complicated, bulky and expensive, thus limiting their usage in industrial field applications. This paper presents the development of a compact wideband precision measurement system based on digital auto-balancing bridge. The methods of digital auto-balancing bridge and digital lock-in amplifier are analyzed theoretically. The overall design and several key sections including null detector, direct digital synthesizer-based sampling clock, and digital control unit are introduced in detail. The results show that the system achieves a basic measurement accuracy of 0.05% with a frequency range of 20 Hz–2 MHz. The advantages of versatile measurement capacity, fast measurement speed, small size and low cost make it quite suitable for industrial field applications. It is demonstrated that this system is practical and effective by applying in determining the impedance-temperature characteristic of a motor starter PTC thermistor. (paper)

  13. TECHNICAL NOTE: Portable audio electronics for impedance-based measurements in microfluidics

    Science.gov (United States)

    Wood, Paul; Sinton, David

    2010-08-01

    We demonstrate the use of audio electronics-based signals to perform on-chip electrochemical measurements. Cell phones and portable music players are examples of consumer electronics that are easily operated and are ubiquitous worldwide. Audio output (play) and input (record) signals are voltage based and contain frequency and amplitude information. A cell phone, laptop soundcard and two compact audio players are compared with respect to frequency response; the laptop soundcard provides the most uniform frequency response, while the cell phone performance is found to be insufficient. The audio signals in the common portable music players and laptop soundcard operate in the range of 20 Hz to 20 kHz and are found to be applicable, as voltage input and output signals, to impedance-based electrochemical measurements in microfluidic systems. Validated impedance-based measurements of concentration (0.1-50 mM), flow rate (2-120 µL min-1) and particle detection (32 µm diameter) are demonstrated. The prevailing, lossless, wave audio file format is found to be suitable for data transmission to and from external sources, such as a centralized lab, and the cost of all hardware (in addition to audio devices) is ~10 USD. The utility demonstrated here, in combination with the ubiquitous nature of portable audio electronics, presents new opportunities for impedance-based measurements in portable microfluidic systems.

  14. Evaluation of impedance on biological Tissues using automatic control measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo [Pusan National University, Yangsan (Korea, Republic of); Lee, Moo Seok; Kim, Sang Sik [Pusan National University, Busan (Korea, Republic of); Kim, Gun FDo; Lee, Jong Kyu [Pukyung National University, Busan (Korea, Republic of)

    2015-08-15

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  15. Evaluation of impedance on biological Tissues using automatic control measurement system

    International Nuclear Information System (INIS)

    Kil, Sang Hyeong; Shin, Dong Hoon; Lee, Seong Mo; Lee, Moo Seok; Kim, Sang Sik; Kim, Gun FDo; Lee, Jong Kyu

    2015-01-01

    Each biological tissue has endemic electrical characteristics owing to various differences such as those in cellular arrangement or organization form. The endemic electrical characteristics change when any biological change occurs. This work is a preliminary study surveying the changes in the electrical characteristics of biological tissue caused by radiation exposure. For protection against radiation hazards, therefore the electrical characteristics of living tissue were evaluated after development of the automatic control measurement system using LabVIEW. No alteration of biological tissues was observed before and after measurement of the electrical characteristics, and the biological tissues exhibited similar patterns. Through repeated measurements using the impedance/gain-phase analyzer, the coefficient of variation was determined as within 10%. The reproducibility impedance phase difference in electrical characteristics of the biological tissue did not change, and the tissue had resistance. The absolute value of impedance decreased constantly in proportion to the frequency. It has become possible to understand the electrical characteristics of biological tissues through the measurements made possible by the use of the developed.

  16. Inverse Relation between Condition of Heart Failure and Intrathoracic Impedance Measured by Implantable Cardioverter Defibrillator—A case report—

    Directory of Open Access Journals (Sweden)

    Kohei Matsushita, MD

    2005-01-01

    Full Text Available The patient was a 78-year-old man with dilated cardiomyopathy. His cardio-thoracic ratio was 60.4% and left ventricular ejection fraction (LVEF was 33%. He had been repeatedly admitted for congestive heart failure. He underwent implantation of an implantable cardioverter-defibrillator (ICD for ventricular fibrillation. We compared the values of BNP and shock impedance stored by the ICD. The correlation coefficient (p-value between BNP and shock impedance was −0.700 (p < 0.0005, increase of BNP and shock impedance was −0.778 (p < 0.0001, percent increase of BNP and shock impedance was −0.767 (p < 0.0005. In conclusion, there is an inverse relation between BNP and shock impedance, and measurements of shock impedance may be useful in the management of congestive heart failure.

  17. Corrosion monitoring of iron, protected by an organic coating, with the aid of impedance measurements

    International Nuclear Information System (INIS)

    Hubrecht, J.; Piens, M.; Vereecken, J.

    1984-01-01

    The ac impedance measurement has proved to be a useful electrochemical technique for mainly qualitative studies of electrochemical and corrosion systems. Even for complicated systems such as coated metals in corrosive environments this technique has been used with success. The system chosen for the present study is an ARMCO iron plate, coated with a SrCrO 4 -pigmented styrene acrylic polymer, and immersed for several weeks in an aqueous NaCl solution. Impedance measurements analyze a system under test into its constituting phenomena. The dependence of system parameters on coating layer thickness, NaCl concentration, and pigmentation of the coating during the immersion time provides insight into the corrosion and protection mechanisms at the coating/metal interface, besides the behavior of the coating itself

  18. On the Usage of Cyclic Voltammetry and Impedance Spectroscopy for Measuring the Concentration of Aqueous Solutions

    Directory of Open Access Journals (Sweden)

    Manuel Fiedler

    2015-02-01

    Full Text Available This article describes sensors for concentration measurement based on the electro- chemical properties of the liquid being measured. Herein two electrical methods, namely cyclic voltammetry and impedance spectroscopy, are being presented. The measurement can be performed quasi simultaneously using the same measurement medium. Further optimization of the combined methods is possible by adapting the geometric design of the electrode structure, the electrode material, the optional passivation and the electric coupling (galvanically or capacitively. In summary, by combining multiple sensory principles on a device it becomes possible to analyze mixtures of substances contained in a solution with respect to their composition.

  19. Impedance measurements on a fast transition-edge sensor for optical and near-infrared range

    International Nuclear Information System (INIS)

    Taralli, E; Portesi, C; Lolli, L; Monticone, E; Rajteri, M; Novikov, I; Beyer, J

    2010-01-01

    Impedance measurements of superconducting transition-edge sensors (TESs) are a powerful tool to obtain information about the TES thermal and electrical properties. We apply this technique to a 20 μm x 20 μm Ti/Au TES, suitable for application in the optical and near-infrared range, and extend the measurements up to 250 kHz in order to obtain a complete frequency response in the complex plane. From these measurements we obtain important thermal and electrical device parameters such as heat capacity C, thermal conductance G and effective thermal time constant τ eff that will be compared with the corresponding values obtained from noise measurements.

  20. Impedance Measurements Could Accelerate Phage-Based Identification of Bacillus anthracis and Other Bacteria

    Science.gov (United States)

    2016-09-01

    Impedance Measurements Could Accelerate Phage-Based Identification of Bacillus anthracis And Other Bacteria Thomas Brown, Salwa Shan, Teresa...infection can be detected as early as one hour after exposing as few as 105 CFU bacteria to the stressor. We predicted that similar responses could be used... bacteria to form confluent growth and for phage-induced plaques to appear. Techniques that permit faster detection of species-specific bacteria /phage

  1. Kinetic mechanism of steel corrosion in clay soils by impedance measurements

    International Nuclear Information System (INIS)

    Arpaia, M.; Pernice, P.; Costantini, A.

    1990-01-01

    The corrosion of steel in clay soil at m.c. 15% has been studied for a long exposure time by electrochemical methods. A.c. impedance measurements results show that at a short exposure time the corrosion process is controlled by the diffusion of H + coupled with a rate determining homogeneous reaction, whereas at a long exposure time the process is controlled by pure diffusion. We have hypothesized that the rate determining homogeneous reaction might be the clay particles cations exchange. (orig.)

  2. Development of in vivo impedance spectroscopy techniques for measurement of micropore formation following microneedle insertion.

    Science.gov (United States)

    Brogden, Nicole K; Ghosh, Priyanka; Hardi, Lucia; Crofford, Leslie J; Stinchcomb, Audra L

    2013-06-01

    Microneedles (MNs) provide a minimally invasive means to enhance skin permeability by creating micron-scale channels (micropores) that provide a drug delivery pathway. Adequate formation of the micropores is critical to the success of this unique drug delivery technique. The objective of the current work was to develop sensitive and reproducible impedance spectroscopy techniques to monitor micropore formation in animal models and human subjects. Hairless guinea pigs, a Yucatan miniature pig, and human volunteers were treated with 100 MN insertions per site following an overnight prehydration period. Repeated measurements were made pre- and post-MN treatment using dry and gel Ag/AgCl electrodes applied with light verses direct pressure to hold the electrode to the skin surface. Impedance measurements dropped significantly post-MN application at all sites (p micropore formation. In the Yucatan pig and human subjects, gel electrodes with direct pressure yielded the lowest variability (demonstrated by lower %relative standard deviation), whereas dry electrodes with direct pressure were superior in the guinea pigs. These studies confirm that impedance measurements are suitable for use in both clinical and animal research environments to monitor the formation of new micropores that will allow for drug delivery through the impermeable skin layers. Copyright © 2013 Wiley Periodicals, Inc.

  3. Gravity-dependent ventilation distribution in rats measured with electrical impedance tomography

    International Nuclear Information System (INIS)

    Rooney, Daniel; Fraser, John F; R Dunster, Kimble; Schibler, Andreas; Friese, Marlies

    2009-01-01

    Ventilation in larger animals and humans is gravity dependent and mainly distributed to the dependent lung. Little is known of the effect of gravity on ventilation distribution in small animals such as rodents. The aim of this study was to investigate gravity-dependent ventilation distribution and regional filling characteristics in rats. Ventilation distribution and regional lung filling were measured in six rats using electrical impedance tomography (EIT). Measurements were performed in four body positions (supine, prone, left and right lateral), and all animals were ventilated with increasing tidal volumes from 3 to 8 mL kg −1 . The effect of gravity on regional ventilation distribution was assessed with profiles of relative impedance change and calculation of the geometric centre. Regional filling was measured by calculating the slope of the plot of regional versus global relative impedance change on a breath-by-breath basis. Ventilation was significantly distributed to the non-dependent lung regardless of body position and tidal volume used. The geometric centre was located in the dependent lung in all but prone position. The regional filling characteristics followed an anatomical pattern with the posterior and the right lung generally filling faster. Gravity had little impact on regional filling. Ventilation distribution in rats is gravity dependent, whereas regional filling characteristics are dependent on anatomy

  4. Amplifier spurious input current components in electrode-electrolyte interface impedance measurements

    Directory of Open Access Journals (Sweden)

    Madrid Rossana E

    2005-03-01

    Full Text Available Abstract Background In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 101 to 107 [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. Methods Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a ultra-low bias current amplifiers, (b isolating relays for the selection of cells, and (c a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. Results It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of ± 0.2 [°C]. Frequency did not influence either. Conclusion The drift originated either at the dc input bias offset current (Ios of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure.

  5. Measurements of complex impedance in microwave high power systems with a new bluetooth integrated circuit.

    Science.gov (United States)

    Roussy, Georges; Dichtel, Bernard; Chaabane, Haykel

    2003-01-01

    By using a new integrated circuit, which is marketed for bluetooth applications, it is possible to simplify the method of measuring the complex impedance, complex reflection coefficient and complex transmission coefficient in an industrial microwave setup. The Analog Devices circuit AD 8302, which measures gain and phase up to 2.7 GHz, operates with variable level input signals and is less sensitive to both amplitude and frequency fluctuations of the industrial magnetrons than are mixers and AM crystal detectors. Therefore, accurate gain and phase measurements can be performed with low stability generators. A mechanical setup with an AD 8302 is described; the calibration procedure and its performance are presented.

  6. Development of an Algorithm for Automatic Analysis of the Impedance Spectrum Based on a Measurement Model

    Science.gov (United States)

    Kobayashi, Kiyoshi; Suzuki, Tohru S.

    2018-03-01

    A new algorithm for the automatic estimation of an equivalent circuit and the subsequent parameter optimization is developed by combining the data-mining concept and complex least-squares method. In this algorithm, the program generates an initial equivalent-circuit model based on the sampling data and then attempts to optimize the parameters. The basic hypothesis is that the measured impedance spectrum can be reproduced by the sum of the partial-impedance spectra presented by the resistor, inductor, resistor connected in parallel to a capacitor, and resistor connected in parallel to an inductor. The adequacy of the model is determined by using a simple artificial-intelligence function, which is applied to the output function of the Levenberg-Marquardt module. From the iteration of model modifications, the program finds an adequate equivalent-circuit model without any user input to the equivalent-circuit model.

  7. Complex numbers in chemometrics: examples from multivariate impedance measurements on lipid monolayers.

    Science.gov (United States)

    Geladi, Paul; Nelson, Andrew; Lindholm-Sethson, Britta

    2007-07-09

    Electrical impedance gives multivariate complex number data as results. Two examples of multivariate electrical impedance data measured on lipid monolayers in different solutions give rise to matrices (16x50 and 38x50) of complex numbers. Multivariate data analysis by principal component analysis (PCA) or singular value decomposition (SVD) can be used for complex data and the necessary equations are given. The scores and loadings obtained are vectors of complex numbers. It is shown that the complex number PCA and SVD are better at concentrating information in a few components than the naïve juxtaposition method and that Argand diagrams can replace score and loading plots. Different concentrations of Magainin and Gramicidin A give different responses and also the role of the electrolyte medium can be studied. An interaction of Gramicidin A in the solution with the monolayer over time can be observed.

  8. Passivation of mechanically polished, chemically etched and anodized zirconium in various aqueous solutions: Impedance measurements

    International Nuclear Information System (INIS)

    Abo-Elenien, G.M.; Abdel-Salam, O.E.

    1987-01-01

    Zirconium and its alloys are finding increasing applications especially in water-cooled nuclear reactors. Because of the fact that zirconium is electronegative (E 0 = -1.529V) its corrosion resistance in aqueous solutions is largely determined by the existence of a thin oxide film on its surface. The structure and properties of this film depend in the first place on the method of surface pre-treatment. This paper presents an experimental study of the nature of the oxide film on mechanically polished, chemically etched and anodized zirconium. Ac impedance measurements carried out in various acidic, neutral and alkaline solutions show that the film thickness depends on the method of surface pre-treatment and the type of electrolyte solution. The variation of the potential and impedance during anodization of zirconium at low current density indicates that the initial stages of polarization consist of oxide build-up at a rate dependent on the nature of the electrode surface and the electrolyte. Oxygen evolution commences at a stage where oxide thickening starts to decline. The effect of frequency on the measured impedance indicates that the surface reactivity, and hence the corrosion rate, decreases in the following order: mechanically polished > chemically etched > anodized

  9. Impedance measurements and simulations for the LHC and HL-LHC injection protection collimator

    CERN Document Server

    AUTHOR|(CDS)2125995; Biancacci, Nicolò

    This thesis focuses on the study and the data analysis of the Injection Protection Collimator (also Injection Protection Target Dump or TDI), one of the Large Hadron Collider (LHC) collimators at CERN, in Geneva. The last chapters also deal with the Segmented TDI (TDIS), the TDI upgrade for High Luminosity-LHC (HL-LHC). Going more into details, measurements on the TDI - hexagonal Boron Nitride (TDI - hBN, installed in the LHC during run 2015) were carried out. Using the obtained results as an input, two derivations followed: one evaluating the layer resistivity and the other one for its thickness, in order to consider all the possible coating degradations that could occur. The whole range of data obtained from both the derivations was then fed to Impedance Wake 2D (IW2D), a code performing numerical simulations, to attain impedances. Finally, the resulting longitudinal impedance was compared to some measurements performed on the real TDIs, immediately after they were removed from the LHC. The TDI - Graphite, ...

  10. Measurement of thin liquid film drainage using a novel high-speed impedance analyzer

    Science.gov (United States)

    Hool, Kevin O.; Saunders, Robert C.; Ploehn, Harry J.

    1998-09-01

    This work describes the design and implementation of a new instrument, called the thin film impedance analyzer, which measures the rate of drainage of thin oil films. The instrument forms an oil film by elevating a planar oil-water interface into a water drop hanging from a stainless steel capillary tube immersed in the oil. The instrument measures the magnitude of the impedance of the matter between the capillary tube and a screen electrode immersed in the lower water phase. Under appropriate conditions, the capacitance of the oil film dominates the impedance. The instrument records the increase in the magnitude of the admittance associated with the draining and thinning of the oil film. The features of the drainage curves vary considerably with the type, amount, and location of surfactants in the oil and water phases, as well as with user-specified values of drop volume, drop equilibration time, and extent of drop compression. For this reason, the instrument has utility as a screening tool for selecting surfactants for emulsion formulations. Potential future uses include accelerated prediction of emulsion stability and extraction of oil-water interfacial rheological parameters.

  11. Evaluation method for corrosion level of rebar in RC with electrical impedance measurement

    Science.gov (United States)

    Sasamoto, Akira

    2018-04-01

    The author reported that the impedance measurement using the 4-terminal method on the RC surface for diagnosing corrosion of internal rebar. The difference between the maximum value at 0.01 Hz and the minimum value around 10 Hz indicates the corrosion level of rebar in that report. This is successive report on a signal processing method for estimating the corrosion level by the measured impedance data to obtain more high accuracy. In the dielectric, a graph of frequency and dielectric constant (Cole-Cole plot diagram by KS Cole and RH Cole article of 1941) draws a shape of circle if the dielectric is independent of frequency but it draws a shape of ellipse in reality due to frequency dependency. Havriliak and Negami have also presented Havriliak-Negami model which introduced parameter into dielectric constant equation which deforms Cole-Cole plot diagram and showed that acquired dielectric data of polymer materials fit to this model with proper parameters. In this report, we first consider electric model connected with resistance and capacitance as a rough model of RC concrete. If the capacitance in this model circuit has some loss of dielectric, it is stated that graph in impedance plot is expected to take as similar deformation in the dielectric Cole-Cole plot. Then a numerical optimization computer code for obtaining parameters in the Cole-Cole plot diagram and Havriliak-Negami model is constructed, and the correlation between the deformation parameter of each model and corrosion is shown by this code. These results are feasibility study for diagnosis of corrosion level of rebar by associated parameters to a shape of impedance graph.

  12. Peripheral vascular effects on auscultatory blood pressure measurement.

    Science.gov (United States)

    Rabbany, S Y; Drzewiecki, G M; Noordergraaf, A

    1993-01-01

    Experiments were conducted to examine the accuracy of the conventional auscultatory method of blood pressure measurement. The influence of the physiologic state of the vascular system in the forearm distal to the site of Korotkoff sound recording and its impact on the precision of the measured blood pressure is discussed. The peripheral resistance in the arm distal to the cuff was changed noninvasively by heating and cooling effects and by induction of reactive hyperemia. All interventions were preceded by an investigation of their effect on central blood pressure to distinguish local effects from changes in central blood pressure. These interventions were sufficiently moderate to make their effect on central blood pressure, recorded in the other arm, statistically insignificant (i.e., changes in systolic [p cooling experiments was statistically significant (p < 0.001). Moreover, both measured systolic (p < 0.004) and diastolic (p < 0.001) pressure decreases during the reactive hyperemia experiments were statistically significant. The findings demonstrate that alteration in vascular state generates perplexing changes in blood pressure, hence confirming experimental observations by earlier investigators as well as predictions by our model studies.

  13. Producing of Impedance Tube for Measurement of Acoustic Absorption Coefficient of Some Sound Absorber Materials

    Directory of Open Access Journals (Sweden)

    R. Golmohammadi

    2008-04-01

    Full Text Available Introduction & Objective: Noise is one of the most important harmful agents in work environment. In spit of industrial improvements, exposure with over permissible limit of noise is counted as one of the health complication of workers. In Iran, do not exact information of the absorption coefficient of acoustic materials. Iranian manufacturer have not laboratory for measured of sound absorbance of their products, therefore using of sound absorber is limited for noise control in industrial and non industrial constructions. The goal of this study was to design an impedance tube based on pressure method for measurement of the sound absorption coefficient of acoustic materials.Materials & Methods: In this study designing of measuring system and method of calculation of sound absorption based on a available equipment and relatively easy for measurement of the sound absorption coefficient related to ISO10534-1 was performed. Measuring system consist of heavy asbestos tube, a pure tone sound generator, calibrated sound level meter for measuring of some commonly of sound absorber materials was used. Results: In this study sound absorption coefficient of 23 types of available acoustic material in Iran was tested. Reliability of results by three repeat of measurement was tested. Results showed that the standard deviation of sound absorption coefficient of study materials was smaller than .Conclusion: The present study performed a necessary technology of designing and producing of impedance tube for determining of acoustical materials absorption coefficient in Iran.

  14. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery.

    Science.gov (United States)

    Aglzim, El-Hassane; Rouane, Amar; El-Moznine, Reddad

    2007-10-17

    In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee ® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice ® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper).The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5V)and with two imposed currents (0.6A and 4A). The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical) enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  15. An Electronic Measurement Instrumentation of the Impedance of a Loaded Fuel Cell or Battery

    Directory of Open Access Journals (Sweden)

    Reddad El-Moznine

    2007-10-01

    Full Text Available In this paper we present an inexpensive electronic measurement instrumentationdeveloped in our laboratory, to measure and plot the impedance of a loaded fuel cell orbattery. Impedance measurements were taken by using the load modulation method. Thisinstrumentation has been developed around a VXI system stand which controls electroniccards. Software under Hpvee® was developed for automatic measurements and the layout ofthe impedance of the fuel cell on load. The measurement environment, like the ambienttemperature, the fuel cell temperature, the level of the hydrogen, etc..., were taken withseveral sensors that enable us to control the measurement. To filter the noise and theinfluence of the 50Hz, we have implemented a synchronous detection which filters in a verynarrow way around the useful signal. The theoretical result obtained by a simulation underPspice® of the method used consolidates the choice of this method and the possibility ofobtaining correct and exploitable results. The experimental results are preliminary results ona 12V vehicle battery, having an inrush current of 330A and a capacity of 40Ah (impedancemeasurements on a fuel cell are in progress, and will be the subject of a forthcoming paper.The results were plotted at various nominal voltages of the battery (12.7V, 10V, 8V and 5Vand with two imposed currents (0.6A and 4A. The Nyquist diagram resulting from theexperimental data enable us to show an influence of the load of the battery on its internalimpedance. The similitude in the graph form and in order of magnitude of the valuesobtained (both theoretical and practical enables us to validate our electronic measurementinstrumentation. One of the future uses for this instrumentation is to integrate it with several control sensors, on a vehicle as an embedded system to monitor the degradation of fuel cell membranes.

  16. Above-cutoff impedance measurements of pumping holes for the Collider Liner

    International Nuclear Information System (INIS)

    Walling, L.; Barts, T.; Ruiz, E.; Turner, W.; Spayd, N.

    1994-04-01

    A holed liner was considered for the Superconducting Super Collider (SSC) Collider Ring because of vacuum problems caused by photon-induced desorption. The liner would serve to shield the cold surface of the beam tube from the synchrotron radiation and the holes (or slots) would allow distributed pumping by gas-absorption material that could be placed between the liner and the beam tube. The impedance of holes and slots in a liner were studied by means of simulations using both MAFIA and HFSS, analytical modelling, wire measurements and electron beam measurements

  17. The measurement of water transport in porous materials using impedance spectroscopy

    International Nuclear Information System (INIS)

    Ball, R J; Allen, G C

    2010-01-01

    This paper describes the application of electrical measurements to monitor the extraction (movement of water from the mortar) of water from calcium lime, natural hydraulic lime and Portland cement mortars placed on an adsorbent brick substrate. Impedance measurements were used to identify the changes in bulk resistance of the mortar. A model has been developed combining sharp front theory and Boltzmann's distribution law of statistical thermodynamics to identify the point at which no further absorption of water into the brick occurs. A linear relationship was found between the exponential of bulk resistance and the square root of time during dewatering. A change in gradient was attributed to the end of dewatering.

  18. Effect of impedance and higher order chromaticity on the measurement of linear chromaticity

    Directory of Open Access Journals (Sweden)

    V. H. Ranjbar

    2011-08-01

    Full Text Available The combined effect of impedance and higher order chromaticity can act on the beam in a nontrivial manner which can cause a tune shift which depends on the relative momenta with respect to the “on momentum” particle (Δp/p. Experimentally, this tune shift affects the measurement of the linear chromaticity which is traditionally measured with a change of Δp/p. The theory behind this effect will be derived in this paper. Computer simulations and experimental data from the Tevatron will be used to support the theory.

  19. Effect of impedance and higher order chromaticity on the measurement of linear chromaticity

    OpenAIRE

    V. H. Ranjbar; C. Y. Tan

    2011-01-01

    The combined effect of impedance and higher order chromaticity can act on the beam in a nontrivial manner which can cause a tune shift which depends on the relative momenta with respect to the “on momentum” particle (Δp/p). Experimentally, this tune shift affects the measurement of the linear chromaticity which is traditionally measured with a change of Δp/p. The theory behind this effect will be derived in this paper. Computer simulations and experimental data from the Tevatron will be used ...

  20. Predicting burst pressure of radiofrequency-induced colorectal anastomosis by bio-impedance measurement.

    Science.gov (United States)

    Zhao, Lingxi; Zhou, Yu; Song, Chengli; Wang, Zhigang; Cuschieri, Alfred

    2017-03-01

    The present study investigates the relationship between bio-impedance and burst pressure of colorectal anastomosis created by radiofrequency (RF)-induced tissue fusion. Colorectal anastomosis were created with ex vivo porcine colorectal segments, during which 5 levels of compression pressure were applied by a custom-made bipolar prototype, with 5 replicate experiments at each compression pressure. Instant anastomotic tensile strength was assessed by burst pressure. Bio-impedance of fused tissue was measured by Impedance Analyzer across frequency that 100 Hz to 3 MHz. Statistical analysis shows only a weak correlation between bio-impedance modulus and burst pressures at frequency of 445 kHz ([Formula: see text]  =  -0.426, P  =  0.099  >  0.05). In contrast, results demonstrated a highly significant negative correlation between reactance modulus and burst pressures ([Formula: see text]  =  -0.812, P  =  0.000  <  0.05). The decrease in mean reactance modulus with increasing burst pressures was highly significant (P  =  0.019  <  0.05). The observed strong negative correlation between reactance modulus and burst pressures at frequency of 445 kHz indicates that reactance is likely to be a good index for tensile strength of RF-induced colorectal anastomosis, and should be considered for inclusion in a feedback loops in devices design.

  1. Impact of eating and drinking on body composition measurements by bioelectrical impedance.

    Science.gov (United States)

    Androutsos, O; Gerasimidis, K; Karanikolou, A; Reilly, J J; Edwards, C A

    2015-04-01

    Bioelectrical impedance analysis would be a more practical tool to measure body composition in clinical settings, dietetic practice and epidemiological studies if patients/subjects did not have to fast before measurements. The present study assessed whether the ingestion of food or drink had any biologically significant effect on bioimpedance measurements and body composition by the foot-to-foot method. Fifty-five healthy adults [30 males and 25 females; mean (SD) age 27.7 (7.1) years; mean (SD)body mass index 24 (3.8) kg m(-2)] were randomly assigned to a 2-day food trial (high-fat meal or high-carbohydrate meal) or a 2-day drink trial (water or high electrolyte drink). Body composition measurements were carried out in the fasting state, immediately after meal consumption and every 30 min for 2 h by the foot-to-foot single frequency bioimpedance technique. Bioimpedance increased significantly after the ingestion of food and fluid, although the changes were small. The electrolyte drink, high-fat and high-carbohydrate meals significantly increased the percentage body fat and fat mass. In all cases, the median percentage changes from baseline were approximately 1% in body fat percentage units. Although there were statistically significant changes in body composition estimates after food or drink consumption, these were small and within the imprecision of the impedance technique, and so are unlikely to be of clinical significance. The present study suggests that impedance measures of body fatness in clinical settings do not require strict adherence to fasting, and this should increase the opportunities for clinical application. © 2014 The British Dietetic Association Ltd.

  2. A new lithium-ion battery internal temperature on-line estimate method based on electrochemical impedance spectroscopy measurement

    Science.gov (United States)

    Zhu, J. G.; Sun, Z. C.; Wei, X. Z.; Dai, H. F.

    2015-01-01

    The power battery thermal management problem in EV (electric vehicle) and HEV (hybrid electric vehicle) has been widely discussed, and EIS (electrochemical impedance spectroscopy) is an effective experimental method to test and estimate the status of the battery. Firstly, an electrochemical-based impedance matrix analysis for lithium-ion battery is developed to describe the impedance response of electrochemical impedance spectroscopy. Then a method, based on electrochemical impedance spectroscopy measurement, has been proposed to estimate the internal temperature of power lithium-ion battery by analyzing the phase shift and magnitude of impedance at different ambient temperatures. Respectively, the SoC (state of charge) and temperature have different effects on the impedance characteristics of battery at various frequency ranges in the electrochemical impedance spectroscopy experimental study. Also the impedance spectrum affected by SoH (state of health) is discussed in the paper preliminary. Therefore, the excitation frequency selected to estimate the inner temperature is in the frequency range which is significantly influenced by temperature without the SoC and SoH. The intrinsic relationship between the phase shift and temperature is established under the chosen excitation frequency. And the magnitude of impedance related to temperature is studied in the paper. In practical applications, through obtaining the phase shift and magnitude of impedance, the inner temperature estimation could be achieved. Then the verification experiments are conduced to validate the estimate method. Finally, an estimate strategy and an on-line estimation system implementation scheme utilizing battery management system are presented to describe the engineering value.

  3. Rock properties influencing impedance spectra (IS) studied by lab measurements on porous model systems

    Energy Technology Data Exchange (ETDEWEB)

    Volkmann, J.; Klitzsch, N.; Mohnke, O. [RWTH Aachen Univ. (Germany). Applied Geophysics and Geothermal Energy; Schleifer, N. [Wintershall Holding GmbH, Barnstorf (Germany)

    2013-08-01

    The wetting condition of reservoir rocks is a crucial parameter for the estimation of reservoir characteristics like permeability and saturation with residual oil or water. Since standard methods are often costly, at least in terms of time, we aim at assessing wettability of reservoir rocks using impedance spectroscopy (IS), a frequency dependent measurement of complex electric resistivity. This approach is promising, because IS is sensitive to the electrochemical properties of the inner surface of rocks which, on the other hand, are decisively influencing wettability. Unfortunately, there is large number of rock parameters - besides wettability - influencing the impedance spectra often not exactly known for natural rock samples. Therefore, we study model systems to improve the understanding of the underlying mechanisms and to quantify the influencing parameters. The model systems consist of sintered porous silica beads of different sizes leading to samples with different pore sizes. The main advantage of these samples compared to natural rocks is their well-defined and uniform mineralogical composition and thus their uniform electrochemical surface property. In order to distinguish pore geometry and fluid electrochemistry effects on the IS properties we measured the IS response of the fully water saturated model systems in a wide frequency range - from 1 mHz to 35 MHz - to capture different often overlapping polarization processes. With these measurements we study the influence of pore or grain size, fluid conductivity, and wettability (contact angle) on the impedance spectra. The influence of wettability was studied by modifying the originally hydrophilic inner surface into a hydrophobic state. The wettability change was verified by contact angle measurements. As results, we find pore size dependent relaxation times and salinity dependent chargeabilities for the hydrophilic samples in the low frequency range (< 10 kHz), whereas for the hydrophobic samples

  4. Visualized Multiprobe Electrical Impedance Measurements with STM Tips Using Shear Force Feedback Control

    Directory of Open Access Journals (Sweden)

    Luis Botaya

    2016-05-01

    Full Text Available Here we devise a multiprobe electrical measurement system based on quartz tuning forks (QTFs and metallic tips capable of having full 3D control over the position of the probes. The system is based on the use of bent tungsten tips that are placed in mechanical contact (glue-free solution with a QTF sensor. Shear forces acting in the probe are measured to control the tip-sample distance in the Z direction. Moreover, the tilting of the tip allows the visualization of the experiment under the optical microscope, allowing the coordination of the probes in X and Y directions. Meanwhile, the metallic tips are connected to a current–voltage amplifier circuit to measure the currents and thus the impedance of the studied samples. We discuss here the different aspects that must be addressed when conducting these multiprobe experiments, such as the amplitude of oscillation, shear force distance control, and wire tilting. Different results obtained in the measurement of calibration samples and microparticles are presented. They demonstrate the feasibility of the system to measure the impedance of the samples with a full 3D control on the position of the nanotips.

  5. Correlation between electrochemical impedance measurements and corrosion rate of magnesium investigated by real-time hydrogen measurement and optical imaging

    OpenAIRE

    Curioni, M.; Scenini, F.; Monetta, T.; Bellucci, F.

    2015-01-01

    The corrosion behaviour of magnesium in chloride-containing aqueous environment was investigated by potentiodynamic polarization and electrochemical impedance spectroscopy (EIS) performed simultaneously with real-time hydrogen evolution measurements and optical imaging of the corroding surface. The potentiodynamic investigation revealed substantial deviations from linearity in close proximity of the corrosion potential. In particular, differences in the slope of the current/potential curves w...

  6. Structural damage identification using piezoelectric impedance measurement with sparse inverse analysis

    Science.gov (United States)

    Cao, Pei; Qi, Shuai; Tang, J.

    2018-03-01

    The impedance/admittance measurements of a piezoelectric transducer bonded to or embedded in a host structure can be used as damage indicator. When a credible model of the healthy structure, such as the finite element model, is available, using the impedance/admittance change information as input, it is possible to identify both the location and severity of damage. The inverse analysis, however, may be under-determined as the number of unknowns in high-frequency analysis is usually large while available input information is limited. The fundamental challenge thus is how to find a small set of solutions that cover the true damage scenario. In this research we cast the damage identification problem into a multi-objective optimization framework to tackle this challenge. With damage locations and severities as unknown variables, one of the objective functions is the difference between impedance-based model prediction in the parametric space and the actual measurements. Considering that damage occurrence generally affects only a small number of elements, we choose the sparsity of the unknown variables as another objective function, deliberately, the l 0 norm. Subsequently, a multi-objective Dividing RECTangles (DIRECT) algorithm is developed to facilitate the inverse analysis where the sparsity is further emphasized by sigmoid transformation. As a deterministic technique, this approach yields results that are repeatable and conclusive. In addition, only one algorithmic parameter, the number of function evaluations, is needed. Numerical and experimental case studies demonstrate that the proposed framework is capable of obtaining high-quality damage identification solutions with limited measurement information.

  7. Ventilation inhomogeneity in obstructive lung diseases measured by electrical impedance tomography: a simulation study.

    Science.gov (United States)

    Schullcke, B; Krueger-Ziolek, S; Gong, B; Jörres, R A; Mueller-Lisse, U; Moeller, K

    2017-10-10

    Electrical impedance tomography (EIT) has mostly been used in the Intensive Care Unit (ICU) to monitor ventilation distribution but is also promising for the diagnosis in spontaneously breathing patients with obstructive lung diseases. Beside tomographic images, several numerical measures have been proposed to quantitatively assess the lung state. In this study two common measures, the 'Global Inhomogeneity Index' and the 'Coefficient of Variation' were compared regarding their capability to reflect the severity of lung obstruction. A three-dimensional simulation model was used to simulate obstructed lungs, whereby images were reconstructed on a two-dimensional domain. Simulations revealed that minor obstructions are not adequately recognized in the reconstructed images and that obstruction above and below the electrode plane may result in misleading values of inhomogeneity measures. EIT measurements on several electrode planes are necessary to apply these measures in patients with obstructive lung diseases in a promising manner.

  8. Digital PIV Measurements of Acoustic Particle Displacements in a Normal Incidence Impedance Tube

    Science.gov (United States)

    Humphreys, William M., Jr.; Bartram, Scott M.; Parrott, Tony L.; Jones, Michael G.

    1998-01-01

    Acoustic particle displacements and velocities inside a normal incidence impedance tube have been successfully measured for a variety of pure tone sound fields using Digital Particle Image Velocimetry (DPIV). The DPIV system utilized two 600-mj Nd:YAG lasers to generate a double-pulsed light sheet synchronized with the sound field and used to illuminate a portion of the oscillatory flow inside the tube. A high resolution (1320 x 1035 pixel), 8-bit camera was used to capture double-exposed images of 2.7-micron hollow silicon dioxide tracer particles inside the tube. Classical spatial autocorrelation analysis techniques were used to ascertain the acoustic particle displacements and associated velocities for various sound field intensities and frequencies. The results show that particle displacements spanning a range of 1-60 microns can be measured for incident sound pressure levels of 100-130 dB and for frequencies spanning 500-1000 Hz. The ability to resolve 1 micron particle displacements at sound pressure levels in the 100 dB range allows the use of DPIV systems for measurement of sound fields at much lower sound pressure levels than had been previously possible. Representative impedance tube data as well as an uncertainty analysis for the measurements are presented.

  9. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Scheffler, Klaus; Ehses, Philipp

    2017-01-01

    Purpose: Clinical use of magnetic resonance electrical impedance tomography (MREIT) still requires significant sensitivity improvements. Here, the measurement of the current-induced magnetic field (DBz,c) is improved using systematic efficiency analyses and optimization of multi-echo spin echo...... (MESE) and steady-state free precession free induction decay (SSFP-FID) sequences. Theory and Methods: Considering T1, T2, and T 2 relaxation in the signal-to-noise ratios (SNRs) of the MR magnitude images, the efficiency of MESE and SSFP-FID MREIT experiments, and its dependence on the sequence...

  10. Textrode-enabled transthoracic electrical bioimpedance measurements - towards wearable applications of impedance cardiography

    Directory of Open Access Journals (Sweden)

    Juan Carlos Márquez Ruiz

    2013-10-01

    Full Text Available During the last decades the use of Electrical Bioimpedance (EBI in the medical field has been subject of extensive research, especially since it is an affordable, harmless and non-invasive technology. In some specific applications such as body composition assessment where EBI has proven a good degree of effectiveness and reliability, the use of textile electrodes and measurement garments have shown a good performance and reproducible results. Impedance Cardiography (ICG is another modality of EBI that can benefit from the implementation and use of wearable sensors. ICG technique is based on continuous impedance measurements of a longitudinal segment across the thorax taken at a single frequency. The need for specific electrode placement on the thorax and neck can be easily ensured with the use of a garment with embedded textile electrodes, textrodes. The first step towards the implementation of ICG technology into a garment is to find out if ICG measurements with textile sensors give a good enough quality of the signal to allow the estimation of the fundamental ICG parameters. In this work, the measurement performance of a 2-belt set with incorporated textrodes for thorax and neck was compared against ICG measurements obtained with Ag/AgCl electrodes. The analysis was based on the quality of the fundamental ICG signals (∆Z, dZ/dt and ECG, systolic time intervals and other ICG parameters. The obtained results indicate the feasibility of using textrodes for ICG measurements with consistent measurements and relatively low data dispersion. Thus, enabling the development of measuring garments for ICG measurements.

  11. Nonlinear surface impedance of YBCO thin films: Measurements, modeling, and effects in devices

    International Nuclear Information System (INIS)

    Oates, D.E.; Koren, G.; Polturak, E.

    1995-01-01

    High-T c thin films continue to be of interest for passive device applications at microwave frequencies, but nonlinear effects may limit the performance. To understand these effects we have measured the nonlinear effects may limit the performance. To understand these effects we have measured the nonlinear surface impedance Z s in a number of YBa 2 Cu 3 O 7-x thin films as a function of frequency from 1 to 18 GHz, rf surface magnetic field H rf to 1500 Oe, and temperature from 4 K to T c . The results at low H rf are shown to agree quantitatively with a modified coupled-grain model and at high H rf with hysteresis-loss calculations using the Bean critical-state model applied to a thin strip. The loss mechanisms are extrinsic properties resulting from defects in the films. We also report preliminary measurements of the nonlinear impedance of Josephson junctions, and the results are related to the models of nonlinear Z s . The implications of nonlinear Z s for devices are discussed using the example of a five-pole bandpass filter

  12. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    International Nuclear Information System (INIS)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-01-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected. (papers)

  13. Monitoring of pipelines in nuclear power plants by measuring laser-based mechanical impedance

    Science.gov (United States)

    Lee, Hyeonseok; Sohn, Hoon; Yang, Suyoung; Yang, Jinyeol

    2014-06-01

    Using laser-based mechanical impedance (LMI) measurement, this study proposes a damage detection technique that enables structural health monitoring of pipelines under the high temperature and radioactive environments of nuclear power plants (NPPs). The applications of conventional electromechanical impedance (EMI) based techniques to NPPs have been limited, mainly due to the contact nature of piezoelectric transducers, which cannot survive under the high temperature and high radiation environments of NPPs. The proposed LMI measurement technique aims to tackle the limitations of the EMI techniques by utilizing noncontact laser beams for both ultrasound generation and sensing. An Nd:Yag pulse laser is used for ultrasound generation, and a laser Doppler vibrometer is employed for the measurement of the corresponding ultrasound responses. For the monitoring of pipes covered by insulation layers, this study utilizes optical fibers to guide the laser beams to specific target locations. Then, an outlier analysis is adopted for autonomous damage diagnosis. Validation of the proposed LMI technique is carried out on a carbon steel pipe elbow under varying temperatures. A corrosion defect chemically engraved in the specimen is successfully detected.

  14. Validation of bioelectrical-impedance analysis as a measurement of change in body composition in obesity

    International Nuclear Information System (INIS)

    Kushner, R.F.; Kunigk, A.; Alspaugh, M.; Andronis, P.T.; Leitch, C.A.; Schoeller, D.A.

    1990-01-01

    The bioelectrical-impedance-analysis (BIA) method accurately measures body composition in weight-stable subjects. This study validates the use of BIA to measure change in body composition. Twelve obese females underwent weight loss at a mean rate of 1.16 kg/wk. Body composition was measured by deuterium oxide dilution (D2O), BIA, and skinfold anthropometry (SFA) at baseline and at 5% decrements in weight. Highly significant correlations were obtained between D2O and BIA (r = 0.971) and between D2O and SFA (r = 0.932). Overall, BIA predicted change in fat-free mass with greater accuracy (to 0.4 kg) and precision (+/- 1.28 kg) than did anthropometry (to 0.8 kg and +/- 2.58 kg, respectively). We conclude that BIA is a useful clinical method for measuring change in body composition

  15. Automated bead-positioning system for measuring impedances of R-F cavity modes

    International Nuclear Information System (INIS)

    Goldberg, D.A.; Rimmer, R.A.

    1993-05-01

    We describe a fully automated bead puller system which uses stepping motors to position the bead, and an HP-8510 network analyzer to measure the resulting frequency shifts, both devices being under computer control. Longitudinal motion of the bead is used for measurement of cavity shunt impedance. In addition, azimuthal scans at fixed longitudinal position aid in determining the multipole character of higher-order modes. High sensitivity/accuracy is made possible by measuring phase shifts at the unperturbed resonant frequencies (rather than frequency shifts themselves), thereby permitting averaging factors of > 500 with only modest increases in data acquisition time. Sample measurements will be presented. A comprehensive analysis of the experimental results is presented in an accompanying paper

  16. Body fat measurement by bioelectrical impedance and air displacement plethysmography: a cross-validation study to design bioelectrical impedance equations in Mexican adults

    Directory of Open Access Journals (Sweden)

    Valencia Mauro E

    2007-08-01

    Full Text Available Abstract Background The study of body composition in specific populations by techniques such as bio-impedance analysis (BIA requires validation based on standard reference methods. The aim of this study was to develop and cross-validate a predictive equation for bioelectrical impedance using air displacement plethysmography (ADP as standard method to measure body composition in Mexican adult men and women. Methods This study included 155 male and female subjects from northern Mexico, 20–50 years of age, from low, middle, and upper income levels. Body composition was measured by ADP. Body weight (BW, kg and height (Ht, cm were obtained by standard anthropometric techniques. Resistance, R (ohms and reactance, Xc (ohms were also measured. A random-split method was used to obtain two samples: one was used to derive the equation by the "all possible regressions" procedure and was cross-validated in the other sample to test predicted versus measured values of fat-free mass (FFM. Results and Discussion The final model was: FFM (kg = 0.7374 * (Ht2 /R + 0.1763 * (BW - 0.1773 * (Age + 0.1198 * (Xc - 2.4658. R2 was 0.97; the square root of the mean square error (SRMSE was 1.99 kg, and the pure error (PE was 2.96. There was no difference between FFM predicted by the new equation (48.57 ± 10.9 kg and that measured by ADP (48.43 ± 11.3 kg. The new equation did not differ from the line of identity, had a high R2 and a low SRMSE, and showed no significant bias (0.87 ± 2.84 kg. Conclusion The new bioelectrical impedance equation based on the two-compartment model (2C was accurate, precise, and free of bias. This equation can be used to assess body composition and nutritional status in populations similar in anthropometric and physical characteristics to this sample.

  17. Validity of bioelectrical impedance measurement in predicting fat-free mass of Chinese children and adolescents.

    Science.gov (United States)

    Wang, Lin; Hui, Stanley Sai-chuen; Wong, Stephen Heung-sang

    2014-11-15

    The current study aimed to examine the validity of various published bioelectrical impedance analysis (BIA) equations in estimating FFM among Chinese children and adolescents and to develop BIA equations for the estimation of fat-free mass (FFM) appropriate for Chinese children and adolescents. A total of 255 healthy Chinese children and adolescents aged 9 to 19 years old (127 males and 128 females) from Tianjin, China, participated in the BIA measurement at 50 kHz between the hand and the foot. The criterion measure of FFM was also employed using dual-energy X-ray absorptiometry (DEXA). FFM estimated from 24 published BIA equations was cross-validated against the criterion measure from DEXA. Multiple linear regression was conducted to examine alternative BIA equation for the studied population. FFM estimated from the 24 published BIA equations yielded high correlations with the directly measured FFM from DEXA. However, none of the 24 equations was statistically equivalent with the DEXA-measured FFM. Using multiple linear regression and cross-validation against DEXA measurement, an alternative prediction equation was determined as follows: FFM (kg)=1.613+0.742×height (cm)2/impedance (Ω)+0.151×body weight (kg); R2=0.95; SEE=2.45 kg; CV=6.5, 93.7% of the residuals of all the participants fell within the 95% limits of agreement. BIA was highly correlated with FFM in Chinese children and adolescents. When the new developed BIA equations are applied, BIA can provide a practical and valid measurement of body composition in Chinese children and adolescents.

  18. AN ADVANCED CALIBRATION PROCEDURE FOR COMPLEX IMPEDANCE SPECTRUM MEASUREMENTS OF ADVANCED ENERGY STORAGE DEVICES

    Energy Technology Data Exchange (ETDEWEB)

    William H. Morrison; Jon P. Christophersen; Patrick Bald; John L. Morrison

    2012-06-01

    With the increasing demand for electric and hybrid electric vehicles and the explosion in popularity of mobile and portable electronic devices such as laptops, cell phones, e-readers, tablet computers and the like, reliance on portable energy storage devices such as batteries has likewise increased. The concern for the availability of critical systems in turn drives the availability of battery systems and thus the need for accurate battery health monitoring has become paramount. Over the past decade the Idaho National Laboratory (INL), Montana Tech of the University of Montana (Tech), and Qualtech Systems, Inc. (QSI) have been developing the Smart Battery Status Monitor (SBSM), an integrated battery management system designed to monitor battery health, performance and degradation and use this knowledge for effective battery management and increased battery life. Key to the success of the SBSM is an in-situ impedance measurement system called the Impedance Measurement Box (IMB). One of the challenges encountered has been development of an accurate, simple, robust calibration process. This paper discusses the successful realization of this process.

  19. Impedance measures in analysis and characterization of multistable structures subjected to harmonic excitation

    Science.gov (United States)

    Harne, Ryan L.; Goodpaster, Benjamin A.

    2018-01-01

    Structural components susceptible to adverse, post-buckled dynamic behaviors have long challenged the success of applications requiring lightweight, slender curved structures, while researchers have begun to leverage such bistable systems in emerging applications for novel energy attenuation and shape-changing properties. To expedite development and deployment of these built-up platforms containing post-buckled constituents, efficient approaches are required to complement time-consuming full-field models in the prediction of the near- and far-from-equilibrium dynamics. This research meets the need by introducing a semi-analytical model framework to enable the characterization of steady-state responses in multi degree-of-freedom (DOF) and multistable structural systems subjected to harmonic excitation. In so doing, the pathway for assessing impedance measures is created here so as to identify how energy travels and returns within built-up multistable structures. Verified by simulations and qualitatively validated by experiments, the analysis is shown to accurately reproduce both near- and far-from-equilibrium responses including different classes of energetic snap-through dynamics that only exist in such multistable structures. A first look at the impedance measures of different dynamic regimes reveals a connection between damping in multistable structures and the sustainability of far-from-equilibrium oscillations.

  20. Measurement of transient two-phase flow velocity using statistical signal analysis of impedance probe signals

    International Nuclear Information System (INIS)

    Leavell, W.H.; Mullens, J.A.

    1981-01-01

    A computational algorithm has been developed to measure transient, phase-interface velocity in two-phase, steam-water systems. The algorithm will be used to measure the transient velocity of steam-water mixture during simulated PWR reflood experiments. By utilizing signals produced by two, spatially separated impedance probes immersed in a two-phase mixture, the algorithm computes the average transit time of mixture fluctuations moving between the two probes. This transit time is computed by first, measuring the phase shift between the two probe signals after transformation to the frequency domain and then computing the phase shift slope by a weighted least-squares fitting technique. Our algorithm, which has been tested with both simulated and real data, is able to accurately track velocity transients as fast as 4 m/s/s

  1. In vivo bioimpedance measurement of healthy and ischaemic rat brain: implications for stroke imaging using electrical impedance tomography

    International Nuclear Information System (INIS)

    Dowrick, T; Blochet, C; Holder, D

    2015-01-01

    In order to facilitate the imaging of haemorrhagic and ischaemic stroke using frequency difference electrical impedance tomography (EIT), impedance measurements of normal and ischaemic brain, and clotted blood during haemorrhage, were gathered using a four-terminal technique in an in vivo animal model, a first for ischaemic measurements. Differences of 5–10% in impedance were seen between the frequency spectrums of healthy and ischaemic brain, over the frequency range 0–3 kHz, while the spectrum of blood was predominately uniform. The implications of imaging blood/ischaemia in the brain using electrical impedance tomography are discussed, supporting the notion that it will be possible to differentiate stroke from haemorrhage. (paper)

  2. An electrode polarization impedance based flow sensor for low water flow measurement

    International Nuclear Information System (INIS)

    Yan, Tinghu; Sabic, Darko

    2013-01-01

    This note describes an electrode polarization impedance based flow sensor for low water flow measurement. It consists of two pairs of stainless steel electrodes set apart and inserted into a non-conductive flow tube with each pair of electrodes placed diametrically at the opposite sides. The flow sensor is modeled as a typical four-electrode system of which two electrodes are current-carrying and the other two serve as output pick ups. The polarization impedances of the two current carrying electrodes are affected by water flows resulting in changes of differential potential between the two pick-up electrodes which are separated by the same fluid. The interrogation of the two excitation electrodes with dc biased ac signals offers significantly higher sensor sensitivities to flow. The prototype flow sensor constructed for a 20 mm diameter pipeline was able to measure water flow rate as low as tested at 1.06 l h −1 and remained sensitive at a flow rate of 25.18 l h −1 when it was driven with a sinusoidal voltage at 1000 Hz with a peak ac amplitude of 2 V and a dc offset of +8 V. The nonlinear characteristics of the sensor response indicate that the sensor is more sensitive at low flows and will not be able to measure at very high flows. Additional experiments are needed to evaluate the influences of impurities, chemical species, ions constituents, conductivity and temperature over a practical range of residential water conditions, the effects of fluctuating ground signals, measurement uncertainty, power consumption, compensation of effects and practical operations. The flow sensor (principle) presented may be used as (in) a secondary sensor in combination with an existing electronic water meter to extend the low end of measurement range in residential water metering. (technical design note)

  3. Gastric emptying patterns of a liquid meal in newborn infants, measured by epigastric impedance

    DEFF Research Database (Denmark)

    Lange, Aksel; Funch-Jensen, Peter; Thommesen, Peter

    1997-01-01

    time (T50) was calculated. For mature infants it was found to be 6.9 mins. For a second meal given within an hour after the first meal the half emptying time was 5.5 mins (p times were not significant different from mature infants, but the number examined was small......  Epigastric impedance was used to measure patterns of the gastric emptying of a liquid non-caloric meal (5 ml water/kg) in newborn infants. The emptying patterns consisted of two components, theemptying signal - the DC component - and a phasic 3 cycle per minutes (CPM) signal - the AC component.......A periodic change of the impedance signal, the phasic 3 CPM signal, was observed after a meal in 24 of the infants. The median frequency was 3.03 CPM in 20 mature and 2.93 CPM in 4 preterminfants. In 9 infants a phasic 3 CPM signal was observed during fasting state. The median frequency was 2.9 CPM...

  4. Impedance measurements of nanoporosity in electrodeposited ZnO films for DSSC

    Energy Technology Data Exchange (ETDEWEB)

    Dupuy, L.; Haller, S.; Rousset, J.; Donsanti, F.; Guillemoles, J.-F.; Lincot, D. [Institute of R and D on Photovoltaic Energy (IRDEP), UMR 7174 EDF-CNRS-Chimie Paristech, 6 quai Watier, 78400 Chatou (France); Decker, F. [Chemistry Department, ' ' Sapienza' ' Universita di Roma, 00185 Roma (Italy)

    2010-05-15

    Porous ZnO/dye hybrid films have been deposited by cathodic electrodeposition, and their active surface area after dye desorption was evaluated by impedance measurements with the semiconducting electrode polarized in accumulation. Surface area ratios have been deduced for a large number of films from imaginary part Z' vs. frequency measurements, having a constant rate over the frequency range from 0.5 Hz to > 50 Hz. The active surface increased by a factor of roughly 150 per every micron of film with respect to the area of a flat ZnO electrode: this linear relationship held from less than 1 {mu}m up to 9 {mu}m thick films. (author)

  5. Improved electrode positions for local impedance measurements in the lung-a simulation study.

    Science.gov (United States)

    Orschulik, Jakob; Petkau, Rudolf; Wartzek, Tobias; Hochhausen, Nadine; Czaplik, Michael; Leonhardt, Steffen; Teichmann, Daniel

    2016-12-01

    Impedance spectroscopy can be used to analyze the dielectric properties of various materials. In the biomedical domain, it is used as bioimpedance spectroscopy (BIS) to analyze the composition of body tissue. Being a non-invasive, real-time capable technique, it is a promising modality, especially in the field of lung monitoring. Unfortunately, up to now, BIS does not provide any regional lung information as the electrodes are usually placed in hand-to-hand or transthoracic configurations. Even though transthoracic electrode configurations are in general capable of monitoring the lung, no focusing to specific regions is achieved. In order to resolve this issue, we use a finite element model (FEM) of the human body to study the effect of different electrode configurations on measured BIS data. We present evaluation results and show suitable electrode configurations for eight lung regions. We show that, using these optimized configurations, BIS measurements can be focused to desired regions allowing local lung analysis.

  6. Impact of hemodialysis on dual X-ray absorptiometry, bioelectrical impedance measurements, and anthropometry

    DEFF Research Database (Denmark)

    Abrahamsen, Bo; Hansen, T B; Høgsberg, I M

    1996-01-01

    ), bioelectrical impedance analysis (BIA), and simple anthropometry in 19 patients (9 women and 10 men, mean age 46 y) before and after hemodialysis, removing 0.9-4.3 L (x: 2.8L) of ultrafiltrate. The reduction in fat-free mass (FFM) measured by DXA was highly correlated with the ultrafiltrate, as determined...... by the reduction in gravimetric weight (r = 0.975, P FFM reductions (r = 0.66, P ..., was estimated to be 0.6% lower after dialysis. None of the simple anthropometric measurements correlated significantly with the reduction in FFM. In an unmodified clinical setting, DXA appears to be superior to other simple noninvasive methods for determining body composition, particularly when the emphasis...

  7. Wire measurement of impedance of an X-band accelerating structure

    CERN Document Server

    Baboi, N; Dolgashev, V A; Jones, R M; Lewandowski, J R; Tantawi, S G; Wang, J W

    2004-01-01

    Several tens of thousands of accelerator structures will be needed for the next generation of linear collders known as the GLC/NLC (Global Linear Collider/Next Linear Collider). To prevent the beam being driven into a disruptive BBU (Beam Break Up) mode or at the very least, the emittance being signifcantly diluted, it is important to damp down the wakefield left by driving bunches to a manageable level. Manufacturing errors and errors in design need to be measurable and compared with predictions. We develop a circuit model of wire-loaded X-band accelerator structures. This enables the wakefield (the inverse transform of the beam impedance) to be readily computed and compared with the wire measurement. We apply this circuit model to the latest series of accelerating for the GLC/NLC. This circuit model is based upon the single-cell model developed in [1] extended here to complete, multi-cell structures.

  8. Improved FPGA controlled artificial vascular system for plethysmographic measurements

    Directory of Open Access Journals (Sweden)

    Laqua Daniel

    2016-09-01

    Full Text Available The fetal oxygen saturation is an important parameter to determine the health status of a fetus, which is until now mostly acquired invasively. The transabdominal, fetal pulse oximetry is a promising approach to measure this non-invasively and continuously. The fetal pulse curve has to be extracted from the mixed signal of mother and fetus to determine its oxygen saturation. For this purpose efficient algorithms are necessary, which have to be evaluated under constant and reproducable test conditions. This paper presents the improved version of a phantom which can generate artificial pulse waves in a synthetic tissue phantom. The tissue phantom consists of several layers that mimic the different optical properties of the fetal and maternal tissue layers. Additionally an artificial vascular system and a dome, which mimics the bending of the belly of a pregnant woman, are incorporated. To obtain data on the pulse waves, several measurement methods are included, to help understand the behavior of the signals gained from the pulse waves. Besides pressure sensors and a transmissive method we integrated a capacitive approach, that makes use of the so called “Pin Oscillator” method. Apart from the enhancements in the tissue phantom and the measurements, we also improved the used blood substitute, which reproduces the different absorption characteristics of fetal and maternal blood. The results show that the phantom can generate pulse waves similar to the natural ones. Furthermore, the phantom represents a reference that can be used to evaluate the algorithms for transabdominal, fetal pulse oximetry.

  9. Experimental test of proximity effect theories by surface impedance measurements on the Pb-Sn system

    International Nuclear Information System (INIS)

    Hook, J.R.; Battilana, J.A.

    1976-01-01

    The proximity effect in the Pb-Sn system in zero magnetic field has been studied by measuring the surface impedance at 3 GHz of a thin film of tin evaporated on to a bulk lead substrate. The results are compared with the predictions of theories of the proximity effect. It is found that good agreement can be obtained by using a theory due to Hook and Waldram of the spatial variation of the superconducting order parameter Δ inside each metal together with suitable boundary conditions on Δ at the interface between the metals. The required boundary conditions are a generalization to the case of non-zero electron reflection at the interface of the boundary conditions given by Zaitsev for the Ginsburg-Landau equation. (author)

  10. Characterizing a porous road pavement using surface impedance measurement: a guided numerical inversion procedure.

    Science.gov (United States)

    Benoit, Gaëlle; Heinkélé, Christophe; Gourdon, Emmanuel

    2013-12-01

    This paper deals with a numerical procedure to identify the acoustical parameters of road pavement from surface impedance measurements. This procedure comprises three steps. First, a suitable equivalent fluid model for the acoustical properties porous media is chosen, the variation ranges for the model parameters are set, and a sensitivity analysis for this model is performed. Second, this model is used in the parameter inversion process, which is performed with simulated annealing in a selected frequency range. Third, the sensitivity analysis and inversion process are repeated to estimate each parameter in turn. This approach is tested on data obtained for porous bituminous concrete and using the Zwikker and Kosten equivalent fluid model. This work provides a good foundation for the development of non-destructive in situ methods for the acoustical characterization of road pavements.

  11. Pyramidal resistor networks for electrical impedance tomography with partial boundary measurements

    International Nuclear Information System (INIS)

    Borcea, L; Mamonov, A V; Druskin, V; Vasquez, F Guevara

    2010-01-01

    We introduce an inversion algorithm for electrical impedance tomography (EIT) with partial boundary measurements in two dimensions. It gives stable and fast reconstructions using sparse parameterizations of the unknown conductivity on optimal grids that are computed as part of the inversion. We follow the approach in Borcea et al (2008 Inverse Problems 24 035013) and Vasquez (2006 PhD thesis Rice University, Houston, TX, USA) that connects inverse discrete problems for resistor networks to continuum EIT problems, using optimal grids. The algorithm in Borcea et al (2008 Inverse Problems 24 035013) and Vasquez (2006 PhD Thesis Rice University, Houston, TX, USA) is based on circular resistor networks, and solves the EIT problem with full boundary measurements. It is extended in Borcea et al (2010 Inverse Problems 26 045010) to EIT with partial boundary measurements, using extremal quasi-conformal mappings that transform the problem to one with full boundary measurements. Here we introduce a different class of optimal grids, based on resistor networks with pyramidal topology, that is better suited for the partial measurements setup. We prove the unique solvability of the discrete inverse problem for these networks and develop an algorithm for finding them from the measurements of the Dirichlet to Neumann map. Then, we show how to use the networks to define the optimal grids and to approximate the unknown conductivity. We assess the performance of our approach with numerical simulations and compare the results with those in Borcea et al (2010)

  12. Design and test of voltage and current probes for EAST ICRF antenna impedance measurement

    Science.gov (United States)

    Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG

    2018-04-01

    On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.

  13. An impedance bridge measuring the capacitance ratio in the high frequency range up to 1 MHz

    International Nuclear Information System (INIS)

    Kim, Dan Bee; Lee, Hyung Kew; Kim, Wan-Seop

    2017-01-01

    This paper describes a 2-terminal-pair impedance bridge, measuring the capacitance ratio in the high frequency range up to 1 MHz. The bridge was configured with two voltage sources and a phase control unit which enabled the bridge balance by synchronizing the voltage sources with an enhanced phase resolution. Without employing the transformers such as inductive voltage divider, injection and detection transformers, etc, the bridge system is quite simple to set up, and the balance procedure is quick and easy. Using this dual-source coaxial bridge, the 1:1 and 10:1 capacitance ratios were measured with 1 pF–1 nF capacitors in the frequency range from 1 kHz to 1 MHz. The measurement values obtained by the dual-source bridge were then compared with reference values measured using a commercial precision capacitance bridge of AH2700A, the Z -matrix method developed by ourselves, and the 4-terminal-pair coaxial bridge by the Czech Metrological Institute. All the measurements agreed within the reference uncertainty range of an order of 10 −6 –10 −5 , proving the bridge ability as a trustworthy tool for measuring the capacitance ratio in the high frequency range. (paper)

  14. Magnetic resonance electrical impedance tomography for measuring electrical conductivity during electroporation

    International Nuclear Information System (INIS)

    Kranjc, M; Miklavčič, D; Bajd, F; Serša, I

    2014-01-01

    The electroporation effect on tissue can be assessed by measurement of electrical properties of the tissue undergoing electroporation. The most prominent techniques for measuring electrical properties of electroporated tissues have been voltage–current measurement of applied pulses and electrical impedance tomography (EIT). However, the electrical conductivity of tissue assessed by means of voltage–current measurement was lacking in information on tissue heterogeneity, while EIT requires numerous additional electrodes and produces results with low spatial resolution and high noise. Magnetic resonance EIT (MREIT) is similar to EIT, as it is also used for reconstruction of conductivity images, though voltage and current measurements are not limited to the boundaries in MREIT, hence it yields conductivity images with better spatial resolution. The aim of this study was to investigate and demonstrate the feasibility of the MREIT technique for assessment of conductivity images of tissues undergoing electroporation. Two objects were investigated: agar phantoms and ex vivo liver tissue. As expected, no significant change of electrical conductivity was detected in agar phantoms exposed to pulses of all used amplitudes, while a considerable increase of conductivity was measured in liver tissue exposed to pulses of different amplitudes. (paper)

  15. Circular resistor networks for electrical impedance tomography with partial boundary measurements

    International Nuclear Information System (INIS)

    Borcea, L; Mamonov, A V; Druskin, V

    2010-01-01

    We introduce an algorithm for the numerical solution of electrical impedance tomography (EIT) in two dimensions, with partial boundary measurements. The algorithm is an extension of the one in Borcea et al (2008 Inverse Problems 24 035013 (31pp)) and Vasquez (2006 PhD Thesis Rice University, Houston, TX, USA) for EIT with full boundary measurements. It is based on resistor networks that arise in finite volume discretizations of the elliptic partial differential equation for the potential on so-called optimal grids that are computed as part of the problem. The grids are adaptively refined near the boundary, where we measure and expect better resolution of the images. They can be used very efficiently in inversion, by defining a reconstruction mapping that is an approximate inverse of the forward map, and acts therefore as a preconditioner in any iterative scheme that solves the inverse problem via optimization. The main result in this paper is the construction of optimal grids for EIT with partial measurements by extremal quasiconformal (Teichmüller) transformations of the optimal grids for EIT with full boundary measurements. We present the algorithm for computing the reconstruction mapping on such grids, and we illustrate its performance with numerical simulations. The results show an interesting trade-off between the resolution of the reconstruction in the domain of the solution and distortions due to artificial anisotropy induced by the distribution of the measurement points on the accessible boundary

  16. Equivalent circuit parameters of nickel/metal hydride batteries from sparse impedance measurements

    Science.gov (United States)

    Nelatury, Sudarshan Rao; Singh, Pritpal

    In a recent communication, a method for extracting the equivalent circuit parameters of a lead acid battery from sparse (only three) impedance spectroscopy observations at three different frequencies was proposed. It was based on an equivalent circuit consisting of a bulk resistance, a reaction resistance and a constant phase element (CPE). Such a circuit is a very appropriate model of a lead-acid cell at high state of charge (SOC). This paper is a sequel to it and presents an application of it in case of nickel/metal hydride (Ni/MH) batteries, which also at high SOC are represented by the same circuit configuration. But when the SOC of a Ni/MH battery under interrogation goes low, The EIS curve has a positive slope at the low frequency end and our technique yields complex values for the otherwise real circuit parameters, suggesting the need for additional elements in the equivalent circuit and a definite relationship between parameter consistency and SOC. To improvise the previous algorithm, in order that it works reasonably well at both high and low SOCs, we propose three more measurements—two at very low frequencies to include the Warburg response and one at a high frequency to model the series inductance, in addition to the three in the mid frequency band—totally six measurements. In most of the today's instrumentation, it is the user who should choose the circuit configuration and the number of frequencies where impedance should be measured and the accompanying software performs data fitting by complex nonlinear least squares. The proposed method has built into it an SOC-based decision-making capability—both to choose the circuit configuration and to estimate the values of the circuit elements.

  17. High frequency electromagnetic impedance measurements for characterization, monitoring and verification efforts. 1998 annual progress report

    International Nuclear Information System (INIS)

    Becker, A.; Lee, K.H.; Pellerin, L.

    1998-01-01

    'Non-invasive, high-resolution imaging of the shallow subsurface is needed for delineation of buried waste, detection of unexploded ordinance, verification and monitoring of containment structures, and other environmental applications. Electromagnetic measurements at frequencies between 1 and 100 MHz are important for such applications, because the induction number of many targets is small due, and the ability to determine the dielectric permittivity in addition to electrical conductivity of the subsurface is possible. Earlier workers were successful in developing systems for detecting anomalous areas, but no quantifiable information was accurately determined. For high resolution imaging, accurate measurements are necessary so the field data can be mapped into the space of the subsurface parameters. The authors are developing a non-invasive method for accurately imaging the electrical conductivity and dielectric permittivity of the shallow subsurface using the plane wave impedance approach, known as the magnetotelluric (MT) method at low frequencies. Electric and magnetic sensors are being tested in a known area against theoretical predictions, thereby insuring that the data collected with the high-frequency impedance (HFI) system will support high-resolution, multi-dimensional imaging techniques. The summary of the work to date is divided into three sections: equipment procurement, instrumentation, and theoretical developments. For most earth materials, the frequency range from 1 to 100 MHz encompasses a very difficult transition zone between the wave propagation of displacement currents and the diffusive behavior of conduction currents. Test equipment, such as signal generators and amplifiers, does not cover the entire range except at great expense. Hence the authors have divided the range of investigation into three sub-ranges: 1--10 MHz, 10--30 MHz, and 30--100 MHz. Results to date are in the lowest frequency range of 1--10 MHz. Even though conduction currents

  18. Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

    Science.gov (United States)

    2010-01-01

    Background Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. Methods The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were performed using metal needle and violet laser (405 nm) acupuncture at the acupoint Kongzui (LU6). The new system is an improvement on devices previously developed by other researchers for this purpose. Results Skin impedance in the immediate surroundings of the acupoint was lowered reproducibly following needle stimulation and also violet laser stimulation. Conclusions A new instrumentation for skin impedance measurements is presented. The following hypotheses suggested by our results will have to be tested in further studies: Needle acupuncture causes significant, specific local changes of electrical skin impedance parameters. Optical stimulation (violet laser) at an acupoint causes direct electrical biosignal changes. PMID:21092296

  19. Biomedical engineering meets acupuncture - development of a miniaturized 48-channel skin impedance measurement system for needle and laser acupuncture

    Directory of Open Access Journals (Sweden)

    Wang Lu

    2010-11-01

    Full Text Available Abstract Background Due to controversially discussed results in scientific literature concerning changes of electrical skin impedance before and during acupuncture a new measurement system has been developed. Methods The prototype measures and analyzes the electrical skin impedance computer-based and simultaneously in 48 channels within a 2.5×3.5 cm matrix. Preliminary measurements in one person were performed using metal needle and violet laser (405 nm acupuncture at the acupoint Kongzui (LU6. The new system is an improvement on devices previously developed by other researchers for this purpose. Results Skin impedance in the immediate surroundings of the acupoint was lowered reproducibly following needle stimulation and also violet laser stimulation. Conclusions A new instrumentation for skin impedance measurements is presented. The following hypotheses suggested by our results will have to be tested in further studies: Needle acupuncture causes significant, specific local changes of electrical skin impedance parameters. Optical stimulation (violet laser at an acupoint causes direct electrical biosignal changes.

  20. Gastric motility measurement and evaluation of functional dyspepsia by a bio-impedance method

    International Nuclear Information System (INIS)

    Li, Zhangyong; Ren, Chaoshi

    2008-01-01

    In order to investigate the complex course of the electrical and mechanical processes of functional dyspepsia (FD), it is necessary to extract gastric motility information on both electricity and mechanism. According to the clinical standardization, 36 volunteers with functional dyspepsia were selected. The signal processing device has been designed by Chongqing University of Posts and Telecommunications. Multi-resolution analysis (MRA) decomposed the two signals of impedance gastric motility (IGM) and electrogastrogram (EGG) collected from the body surface. The wavelet transform is addressed to separate the IGM and EGG signals from impedance signals due to breathing and blood flow. By means of the energy and frequency spectrum analysis technique, the signals can be classified according to the dominant power and dominant frequency. Some indices, such as frequencies of EGG and IGM, signal power spectrum and dynamic spectrum, the rates of rhythm and power for the normal EGG and IGM and so on, can also be calculated. The primary experiments of gastric motility measurement and evaluation are executed by including healthy humans (control group: CG) and patients with FD (pathologic group: PG). There are significant differences in the temporal-domain and frequency-domain properties between the two groups. The main frequency of the CG belongs to 2–4 CPM and is clear and very regular, while the main frequency of the PG is much disordered. The peak of the maximal power of the CG belongs to 2–4 CPM and 1–2 CPM for the PG. The percentage of normal frequency (PNF) for the CG is 0.704 ± 0.255 and 0.402 ± 1.145 for the PG. The frequency instability coefficient (FIC) for the CG is 0.182 ± 0.059 and 0.374 ± 0.086 for the PG. The percentage of normal power (PNP) for the CG is 0.592 ± 0.044 and 0.468 ± 0.142 for the PG. The power instability coefficient (PIC) for the CG is 1.576 ± 0.481 and 4.006 ± 0.711 for the PG. The results of the experiments show that the proposed

  1. Influence of the sample anticoagulant on the measurements of impedance aggregometry in cardiac surgery

    Directory of Open Access Journals (Sweden)

    Cristina Solomon

    2008-10-01

    postoperative day showed a significant recovery in platelet activity in the samples containing heparin (increase from 30 ± 22 U to 46 ± 27 U for the COLtest and from 70 ± 34 U to 95 ± 32 U for the TRAPtest, p < 0.001, Student’s t-test, while no significant recovery of platelet function could be established in the MEA measurements performed with citrated blood.Conclusions: The choice of blood sample anticoagulant used for impedance aggregometry influenced the platelet aggregation response. Postoperative platelet function recovery was only detected in the heparinized samples. Heparin seems to be better suited than citrate for the analysis of impedance aggregometry in heart surgery.Keywords: cardiac surgery, impedance aggregometry, platelet recovery, sample anticoagulant  

  2. Measurements of impedances for determinating the minimum short-circuit current in main systems 500 V of underground mining establishments

    Energy Technology Data Exchange (ETDEWEB)

    Rittinghaus, D

    1981-09-01

    The complex short-circuit impedances of energized low-voltage main systems were measured with a double-bridge in underground mining operation. The magnitude of the short-circuit currents depends on these impedances. Customary calculations of such currents depend on empirical approximations. To verify the accuracy of these approximations, the measured impedances of 61 nodes in three different main systems were compared with the results of the calculations. The comparison made between the short-circuit currents determined by measurable quantities and the values calculated according to VDE 0118 shows that the stipulated coefficients for calculating the minimum short-circuit currents lie very far on the safe side. An amendment for calculating the short-circuit in accordance with VDE 0118 is therefore suggested.

  3. Tidal breathing flow measurement in awake young children by using impedance pneumography.

    Science.gov (United States)

    Seppä, Ville-Pekka; Pelkonen, Anna S; Kotaniemi-Syrjänen, Anne; Mäkelä, Mika J; Viik, Jari; Malmberg, L Pekka

    2013-12-01

    Characteristics of tidal breathing (TB) relate to lung function and may be assessed even in young children. Thus far, the accuracy of impedance pneumography (IP) in recording TB flows in young children with or without bronchial obstruction has not been evaluated. The aim of this study was to evaluate the agreement between IP and direct flow measurement with pneumotachograph (PNT) in assessing TB flow and flow-derived indices relating to airway obstruction in young children. Tidal flow was recorded for 1 min simultaneously with IP and PNT during different phases of a bronchial challenge test with methacholine in 21 wheezy children aged 3 to 7 years. The agreement of IP with PNT was found to be excellent in direct flow signal comparison, the mean deviation from linearity ranging from 2.4 to 3.1% of tidal peak inspiratory flow. Methacholine-induced bronchoconstriction or consecutive bronchodilation induced only minor changes in the agreement. Between IP and PNT, the obstruction-related tidal flow indices were equally repeatable, and agreement was found to be high, with intraclass correlation coefficients for T PTEF/T E, V PTEF/V E, and parameter S being 0.94, 0.91, and 0.68, respectively. Methacholine-induced changes in tidal flow indices showed significant associations with changes in mechanical impedance of the respiratory system assessed by the oscillometric technique, with the highest correlation found in V PTEF/V E (r = -0.54; P tidal airflow profiles in young children with wheezing disorders.

  4. Method to measure autonomic control of cardiac function using time interval parameters from impedance cardiography

    International Nuclear Information System (INIS)

    Meijer, Jan H; Boesveldt, Sanne; Elbertse, Eskeline; Berendse, H W

    2008-01-01

    The time difference between the electrocardiogram and impedance cardiogram can be considered as a measure for the time delay between the electrical and mechanical activities of the heart. This time interval, characterized by the pre-ejection period (PEP), is related to the sympathetic autonomous nervous control of cardiac activity. PEP, however, is difficult to measure in practice. Therefore, a novel parameter, the initial systolic time interval (ISTI), is introduced to provide a more practical measure. The use of ISTI instead of PEP was evaluated in three groups: young healthy subjects, patients with Parkinson's disease, and a group of elderly, healthy subjects of comparable age. PEP and ISTI were studied under two conditions: at rest and after an exercise stimulus. Under both conditions, PEP and ISTI behaved largely similarly in the three groups and were significantly correlated. It is concluded that ISTI can be used as a substitute for PEP and, therefore, to evaluate autonomic neuropathy both in clinical and extramural settings. Measurement of ISTI can also be used to non-invasively monitor the electromechanical cardiac time interval, and the associated autonomic activity, under physiological circumstances

  5. Non-contact multi-frequency magnetic induction spectroscopy system for industrial-scale bio-impedance measurement

    International Nuclear Information System (INIS)

    O'Toole, M D; Marsh, L A; Davidson, J L; Tan, Y M; Armitage, D W; Peyton, A J

    2015-01-01

    Biological tissues have a complex impedance, or bio-impedance, profile which changes with respect to frequency. This is caused by dispersion mechanisms which govern how the electromagnetic field interacts with the tissue at the cellular and molecular level. Measuring the bio-impedance spectra of a biological sample can potentially provide insight into the sample’s properties and its cellular structure. This has obvious applications in the medical, pharmaceutical and food-based industrial domains. However, measuring the bio-impedance spectra non-destructively and in a way which is practical at an industrial scale presents substantial challenges. The low conductivity of the sample requires a highly sensitive instrument, while the demands of industrial-scale operation require a fast high-throughput sensor of rugged design. In this paper, we describe a multi-frequency magnetic induction spectroscopy (MIS) system suitable for industrial-scale, non-contact, spectroscopic bio-impedance measurement over a bandwidth of 156 kHz–2.5 MHz. The system sensitivity and performance are investigated using calibration and known reference samples. It is shown to yield rapid and consistently sensitive results with good long-term stability. The system is then used to obtain conductivity spectra of a number of biological test samples, including yeast suspensions of varying concentration and a range of agricultural produce, such as apples, pears, nectarines, kiwis, potatoes, oranges and tomatoes. (paper)

  6. Impact of SSSC on Measured Impedance in Single Phase to Ground Fault Condition on 220 kV Transmission Line

    Directory of Open Access Journals (Sweden)

    Mohamed ZELLAGUI

    2012-08-01

    Full Text Available This paper presents and compares the impact of SSSC on measured impedance for single phase to ground fault condition. The presence of Static Synchronous SSSC on a transmission line has a great influence on the ZRelay in distance protection. The protection of the high voltage 220 kV single circuit transmission line in eastern Algerian electrical transmission networks is affected in the case with resistance fault RF. The paper investigate the effect of Static Synchronous Series Compensator (SSSC on the measured impedance (Relay taking into account the distance fault point (n and fault resistance (RF. The resultants simulation is performed in MATLAB software environment.

  7. Transcutaneous Intraluminal Impedance Measurement for Minimally Invasive Monitoring of Gastric Motility: Validation in Acute Canine Models

    Directory of Open Access Journals (Sweden)

    Michael D. Poscente

    2014-01-01

    Full Text Available Transcutaneous intraluminal impedance measurement (TIIM is a new method to cutaneously measure gastric contractions by assessing the attenuation dynamics of a small oscillating voltage emitted by a battery-powered ingestible capsule retained in the stomach. In the present study, we investigated whether TIIM can reliably assess gastric motility in acute canine models. Methods. Eight mongrel dogs were randomly divided into 2 groups: half received an active TIIM pill and half received an identically sized sham capsule. After 24-hour fasting and transoral administration of the pill (active or sham, two force transducers (FT were sutured onto the antral serosa at laparotomy. After closure, three standard cutaneous electrodes were placed on the abdomen, registering the transluminally emitted voltage. Thirty-minute baseline recordings were followed by pharmacological induction of gastric contractions using neostigmine IV and another 30-minute recording. Normalized one-minute baseline and post-neostigmine gastric motility indices (GMIs were calculated and Pearson correlation coefficients (PCCs between cutaneous and FT GMIs were obtained. Statistically significant GMI PCCs were seen in both baseline and post-neostigmine states. There were no significant GMI PCCs in the sham capsule test. Further chronic animal studies of this novel long-term gastric motility measurement technique are needed before testing it on humans.

  8. Optimization of impedance spectroscopy techniques for measuring cutaneous micropore formation after microneedle treatment in an elderly population.

    Science.gov (United States)

    Kelchen, Megan N; Holdren, Grant O; Farley, Matthew J; Zimmerman, M Bridget; Fairley, Janet A; Brogden, Nicole K

    2014-12-01

    The objective of this study was to optimize a reproducible impedance spectroscopy method in elderly subjects as a means to evaluate the effects of microneedles on aging skin. Human volunteers were treated with microneedles at six sites on the upper arm. Repeated impedance measurements were taken pre- and post-microneedle insertion. Two electrode types were evaluated (dry vs. gel), using either light or direct pressure to maintain contact between the electrode and skin surface. Transepidermal water loss (TEWL) was measured as a complementary technique. Five control subjects and nine elderly subjects completed the study. Microneedle insertion produced a significant decrease in impedance from baseline in all subjects (p micropore formation. This was supported by a complementary significant increase in TEWL (p micropore formation in elderly subjects, which will be essential for future studies describing microneedle-assisted transdermal delivery in aging populations.

  9. Effect of Electrode Belt and Body Positions on Regional Pulmonary Ventilation- and Perfusion-Related Impedance Changes Measured by Electric Impedance Tomography.

    Directory of Open Access Journals (Sweden)

    Elin Ericsson

    Full Text Available Ventilator-induced or ventilator-associated lung injury (VILI/VALI is common and there is an increasing demand for a tool that can optimize ventilator settings. Electrical impedance tomography (EIT can detect changes in impedance caused by pulmonary ventilation and perfusion, but the effect of changes in the position of the body and in the placing of the electrode belt on the impedance signal have not to our knowledge been thoroughly evaluated. We therefore studied ventilation-related and perfusion-related changes in impedance during spontaneous breathing in 10 healthy subjects in five different body positions and with the electrode belt placed at three different thoracic positions using a 32-electrode EIT system. We found differences between regions of interest that could be attributed to changes in the position of the body, and differences in impedance amplitudes when the position of the electrode belt was changed. Ventilation-related changes in impedance could therefore be related to changes in the position of both the body and the electrode belt. Perfusion-related changes in impedance were probably related to the interference of major vessels. While these findings give us some insight into the sources of variation in impedance signals as a result of changes in the positions of both the body and the electrode belt, further studies on the origin of the perfusion-related impedance signal are needed to improve EIT further as a tool for the monitoring of pulmonary ventilation and perfusion.

  10. Role of electrogastrography and gastric impedance measurements in evaluation of gastric emptying and motility

    NARCIS (Netherlands)

    Smout, A. J.; Jebbink, H. J.; Akkermans, L. M.; Bruijs, P. P.

    1994-01-01

    Electrogastrography records electrical potential variations brought about by myoelectrical activity of the stomach. Abnormal myoelectrical rhythms such as tachygastrias may also be detected. Electrogastrography provides little information on gastric motility and emptying. Impedance epigastrography

  11. Impedance Measurements as a Tool for the Detection of Endocrine Disrupting Chemicals

    National Research Council Canada - National Science Library

    Sacks, V

    2001-01-01

    ... that mimic estrogenic actions and are assumed to decrease mail fertility and induce hormone related cancers in females, Here we describe a novel, class- selective detector that uses fast impedance...

  12. Current phase control test based on real-time measurement of impedance matrix of ICRF antennas

    Energy Technology Data Exchange (ETDEWEB)

    Saito, K., E-mail: saito@nifs.ac.jp [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Kumazawa, R.; Seki, T.; Kasahara, H.; Yokota, M.; Nomura, G.; Shimpo, F.; Mutoh, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)

    2011-10-15

    New ion cyclotron range of frequencies (ICRF) antennas have just been installed in the large helical device (LHD). These side-by-side ICRF antennas are symmetrical and designed to launch fast waves with various wave numbers parallel to the magnetic field line. The wave number can be controlled by changing the current phase on the straps; however, the mutual coupling between antennas changes antenna impedances, even if the plasma parameters are constant, leading to an increase in the reflected power. In addition to the current phase control, impedance matching devices must be tuned for the protection of tetrode tubes and efficient power injection. For this purpose, the impedance matrix of ICRF antennas must be determined, and it can be deduced from the forward and reflected waves at the outlet of the power amplifier by assuming geometric symmetry and reciprocity of the antennas. Using half-scale antennas, we successfully demonstrated simultaneous impedance matching and current phase control.

  13. Distance Protection Impedance Measurement for Inhomogeneous Multiple-Circuit 400/150 kV Transmission Lines with Shared Towers

    DEFF Research Database (Denmark)

    Bak, Claus Leth; Sigurbjörnsson, Ragnar; Bukh, Bjarne

    2016-01-01

    are interconnected in a simple way but via transformers and infeed from remaining parts of the network. Distance relay measured fault loop impedance shows wide ranges of variations for both phase-phase loops as well as phase-earth loops. No simple relations exist. Simulation models can be used to study fault loop...... impedance for combined faults and thereby shed light on relay trips. This study uses actual fault records, analytical method and PSCAD simulation studies to analyse combined faults in an existing 400 and 150 kV transmission line owned by Danish TSO Energinet.dk. The results clearly show that an accurate...

  14. Electrochemical impedance spectroscopy (EIS) as a tool for measuring corrosion of polymer-coated fasteners used in treated wood

    Science.gov (United States)

    Samuel L. Zelinka; Lorraine Ortiz-Candelaria; Donald S. Stone; Douglas R. Rammer

    2009-01-01

    Currently, many of the polymer-coated fasteners on the market are designed for improved corrosion performance in treated wood; yet, there is no way to evaluate their corrosion performance. In this study, a common technique for measuring the corrosion performance of polymer-coated metals, electrochemical impedance spectroscopy (EIS), was used to evaluate commercial...

  15. Electromagnetic model of a near-field cable-free impedance and gain measurement technique for electrically small antennas

    DEFF Research Database (Denmark)

    Zhang, Jiaying; Pivnenko, Sergey; Breinbjerg, Olav

    2011-01-01

    the signal scattered by it when it is loaded in turn with three known loads. The determination of the antenna impedance and gain is formulated by using the spherical wave expansion technique. The advantages of this measurement technique are summarized as follows. First, the limited dynamic range problem...

  16. Electron Density Measurement on JUICE Mission by Mutual Impedance Technique: MIME Instrument as a Part of RPWI Consortium

    Science.gov (United States)

    Rauch, J. L.; Henri, P.; Wahlund, J. E.; Le Duff, O.; Sene, O.; Colin, F.; Lagoutte, D.; Gilet, N.; Ahlen, L.; Bergman, J.; Gill, R.; Puccio, W.

    2017-09-01

    Mutual Impedance MEasurements (MIME) instrument is a part of the Radio Wave Plasma Investigation (RPWI) consortium which has been selected by European Space Agency (ESA) on the nest planetary mission JJUpiter ICy moons Exploer (JUICE) for a launch in 2022. The goals are to explore Jupiter and its potentially habitable icy moons and to study its plasma environment. Impedance probes, which are well known in geophysical prospection, in particular for ground permittivity investigations, have been successfully transposed to space plasmas diagnostic. Transmitting and receiving electrodes are used for measuring on open circuit the dynamic impedance of the system at several fixed frequencies over a range that includes characteristic frequencies of the ambient plasma. The measurements are then interpreted using a suitable theory and the values of plasma parameters, such as the electron density and possibly the temperature of the plasma can be deduced. To show how powerful this technique is, results obtained in the Earth's plasmasphere by the mutual impedance probe onboard ROSETTA are presented as example. MIME instrument proposal is then described and its ability to make valuable measurements in the Jupiter space environment and in particular around Europe, Callisto and Ganymede is investigated..

  17. Bioelectrical impedance vector analysis (BIVA for measuring the hydration status in young elite synchronized swimmers.

    Directory of Open Access Journals (Sweden)

    Marta Carrasco-Marginet

    Full Text Available The assessment of body hydration is a complex process, and no measurement is valid for all situations. Bioelectrical impedance vector analysis (BIVA has emerged as a relatively novel technique for assessing hydration status in sports. We applied BIVA a to determine hydration changes evoked by an intense synchronized swimming (SS training session; b to characterize the sample of young elite swimmers in relation with a nonathletic reference population; and c to generate its 50%, 75% and 95% percentiles of the bioelectrical variables.Forty-nine elite SS female swimmers of two age categories, comen (Co: 13.9 ± 0.9 years, n = 34 and junior (Jr: 16.3 ± 0.6 years, n = 15, performed a long, high intensity training session. Body mass (BM and bioelectrical variables (R, resistance; Xc, reactance; PA, phase angle; and Z, impedance module were assessed pre- and post-training. BIVA was used to characterize 1 the distribution pattern of the bioelectrical vector (BIA vector for both age groups, and 2 pre- to post-training BIA vector migration. Bioelectrical variables were also correlated with BM change values.Most swimmers were mostly located outside the 75% and some beyond the 95% percentile of the bioelectrical tolerance ellipses of the general population. The BIA vector showed statistically significant differences in both Co (T2 = 134.7, p = 0.0001 and Jr (T2 = 126.2, p < 0.001. Both groups were also bioelectrically different (T2 = 17.6, p < 0.001. After the training session, a decrease in BM (p = 0.0001 and an increase in BIA variables (p = 0.01 was observed. BIVA also showed a significant pre-post vector migration both in Co (T2 = 82.1; p < 0.001 and Jr (T2 = 41.8; p < 0.001. No correlations were observed between BM changes and bioelectrical variables.BIVA showed specific bioelectrical characteristics in young elite SS athletes. Considering the decrease in BM and the migration of the BIA vector, we conclude that the homeostatic hydration status of these

  18. Impedance matching of pillbox-type RF windows and direct measurement of the ceramic relative dielectric constant

    Energy Technology Data Exchange (ETDEWEB)

    Ao, Hiroyuki, E-mail: hiroyuki.ao@j-parc.jp [Japan Atomic Energy Agency (JAEA), J-PARC Center, Accelerator Division, 2-4, Shirakara Shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Asano, Hiroyuki [Japan Atomic Energy Agency (JAEA), J-PARC Center, Accelerator Division, 2-4, Shirakara Shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Naito, Fujio [High Energy Accelerator Research Organization (KEK), 1-1, Oho, Tsukuba, Ibaraki 305-0801 (Japan); Ouchi, Nobuo; Tamura, Jun [Japan Atomic Energy Agency (JAEA), J-PARC Center, Accelerator Division, 2-4, Shirakara Shirane, Tokai, Naka, Ibaraki 319-1195 (Japan); Takata, Koji [High Energy Accelerator Research Organization (KEK), 1-1, Oho, Tsukuba, Ibaraki 305-0801 (Japan)

    2014-02-11

    Impedance matching of RF windows that minimizes the RF reflection is necessary to prevent localized standing waves between an RF window and a cavity, which may cause thermal and/or multipactoring issues. It has been observed that the impedance matching condition of the pillbox-type RF window, checked by voltage standing wave ratio (VSWR) measurement, depends on the manufacturing lot of the window ceramic disk made of 95% purity Al{sub 2}O{sub 3}. The present report proposes new procedures for impedance matching as follows: (i) The relative dielectric constant of the ceramic window is directly measured using the resonant frequency of a cavity made by temporarily combining the pillbox part of the RF window and two short-circuiting plates. (ii) The dimensions of the pillbox section including the ceramic disk are fixed on the basis of the measured relative dielectric constant. To confirm this procedure, three RF windows were fabricated using the same type of ceramic material, and successful impedance matching of these windows was performed (VSWR<1.05). The measured results also suggest that the relative dielectric constant increases linearly with increasing density and that the impedance matching condition is mainly affected by variations of the relative dielectric constant due to shrinkage of the alumina during sintering. -- Highlights: • We measured the relative dielectric constant of an RF window ceramic directly. • We used the circular TE011-mode frequency of the pillbox part of an RF window itself. • The dimensions of the pillbox part were fixed on the basis of the measurement result. • Three RF windows were fabricated, and VSWR <1.05 for these windows was performed. • The relative dielectric constant increases linearly with increasing ceramic density.

  19. Impedance matching of pillbox-type RF windows and direct measurement of the ceramic relative dielectric constant

    International Nuclear Information System (INIS)

    Ao, Hiroyuki; Asano, Hiroyuki; Naito, Fujio; Ouchi, Nobuo; Tamura, Jun; Takata, Koji

    2014-01-01

    Impedance matching of RF windows that minimizes the RF reflection is necessary to prevent localized standing waves between an RF window and a cavity, which may cause thermal and/or multipactoring issues. It has been observed that the impedance matching condition of the pillbox-type RF window, checked by voltage standing wave ratio (VSWR) measurement, depends on the manufacturing lot of the window ceramic disk made of 95% purity Al 2 O 3 . The present report proposes new procedures for impedance matching as follows: (i) The relative dielectric constant of the ceramic window is directly measured using the resonant frequency of a cavity made by temporarily combining the pillbox part of the RF window and two short-circuiting plates. (ii) The dimensions of the pillbox section including the ceramic disk are fixed on the basis of the measured relative dielectric constant. To confirm this procedure, three RF windows were fabricated using the same type of ceramic material, and successful impedance matching of these windows was performed (VSWR<1.05). The measured results also suggest that the relative dielectric constant increases linearly with increasing density and that the impedance matching condition is mainly affected by variations of the relative dielectric constant due to shrinkage of the alumina during sintering. -- Highlights: • We measured the relative dielectric constant of an RF window ceramic directly. • We used the circular TE011-mode frequency of the pillbox part of an RF window itself. • The dimensions of the pillbox part were fixed on the basis of the measurement result. • Three RF windows were fabricated, and VSWR <1.05 for these windows was performed. • The relative dielectric constant increases linearly with increasing ceramic density

  20. The design evaluation of inductive power-transformer for personal rapid transit by measuring impedance

    International Nuclear Information System (INIS)

    Han, Kyung-Hee; Lee, Byung-Song; Baek, Soo-Hyun

    2008-01-01

    The contact-less inductive power transformer (IPT) uses the principle of electromagnetic induction. The concept of the IPT for vehicles such as the personal rapid transit (PRT) system is proposed and some suggestions for power collector design of IPT to improve power transfer performance are presented in this paper. The aim of this paper is to recommend the concept of IPT for vehicles such as the PRT system and also to present some propositions for the power collector design of the IPT, which is to improve the power transfer performance. Generally, there are diverse methods to evaluate transfer performance of the traditional transformers. Although the principle of IPT is similar to that of the general transformer, it is impossible to apply the methods directly because of large air gap. The system must be compensated by resonant circuit due to the large air gap. Consequently, it is difficult to apply numerical formulas to the magnetic design of IPT systems. This paper investigates the magnetic design of a PRT system using three-dimensional magnetic modeling and measurements of the pick-up coupling coefficient and its impedances. In addition, how the use of Litz wire and leakage inductance is related will be observed through experiment and simulation

  1. In-situ electrochemical impedance spectroscopy measurements of zirconium alloy oxide conductivity: Relationship to hydrogen pickup

    International Nuclear Information System (INIS)

    Couet, Adrien; Motta, Arthur T.; Ambard, Antoine; Livigni, Didier

    2017-01-01

    Highlights: • In-situ electrochemistry on zirconium alloys in 360 °C pure water show oxide layer resistivity changes during corrosion. • A linear relationship is observed between oxide resistivity and instantaneous hydrogen pickup fraction. • The resistivity of the oxide layer formed on Zircaloy-4 (and thus its hydrogen pickup fraction) is higher than on Zr-2.5Nb. - Abstract: Hydrogen pickup during nuclear fuel cladding corrosion is a critical life-limiting degradation mechanism for nuclear fuel. Following a program dedicated to zirconium alloys, corrosion, it has been hypothesized that oxide electronic resistivity determines hydrogen pickup. In-situ electrochemical impedance spectroscopy experiments were performed on Zircaloy-4 and Zr-2.5Nb alloys in 360 °C water. The oxide resistivity was measured as function of time. The results show that as the oxide resistivity increases so does the hydrogen pickup fraction. The resistivity of the oxide layer formed on Zircaloy-4 is higher than on Zr-2.5Nb, resulting in a higher hydrogen pickup fraction of Zircaloy-4, compared to Zr-2.5Nb.

  2. Numerical investigation of micro-macro coupling in magneto-impedance sensors for weak field measurements

    Science.gov (United States)

    Eason, Kwaku

    There is strong interest in the use of small low-cost highly sensitive magnetic field sensors for applications (e.g. biomedical devices) requiring weak field measurements. Among weak-field sensors, the magneto-impedance (MI) sensor has demonstrated an absolute resolution of 10-11 T. The MI effect is a sensitive realignment of a periodic magnetization in response to an external field in small ferromagnets. However, design of MI sensors has relied primarily on trial and error experimental methods along with decoupled models describing the MI effect. To offer a basis for more cost-effective designs, this thesis research begins with a general formulation describing MI sensors, which relaxes assumptions commonly made for decoupling. The coupled set of nonlinear equations is solved numerically using an efficient meshless method in a point collocation formulation. For the problem considered, the chosen method is shown to offer advantages over alternative methods including the finite element method. Projection methods are used to stabilize the time discretization while quasi-Newton methods (nonlinear solver) are shown to be more computationally efficient, as well. Specifically, solutions for two MI sensor element geometries are presented, which were validated against published experimental data. While the examples illustrated here are for MI sensors, the approach presented can also be extended to other weak-field sensors like fluxgate and Hall effect sensors.

  3. Compressed sampling for boundary measurements in three-dimensional electrical impedance tomography

    International Nuclear Information System (INIS)

    Javaherian, Ashkan; Soleimani, Manuchehr

    2013-01-01

    Electrical impedance tomography (EIT) utilizes electrodes on a medium's surface to produce measured data from which the conductivity distribution inside the medium is estimated. For the cases that relocation of electrodes is impractical or no a priori assumptions can be made to optimize the electrodes placement, a large number of electrodes may be needed to cover all possible imaging volume. This may occur in dynamically varying conductivity distribution in 3D EIT. Three-dimensional EIT then requires inverting very large linear systems to calculate the conductivity field, which causes significant problems regarding storage space and reconstruction time in addition to that data acquisition for a large number of electrodes will reduce the achievable frame rate, which is considered as major advantage of EIT imaging. This study proposes an idea to reduce the reconstruction complexity based on the well-known compressed sampling theory. By applying the so-called model-based CoSaMP algorithm to large size data collected by a 256 channel system, the size of forward operator and data acquisition time is reduced to those of a 32 channel system, while accuracy of reconstruction is significantly improved. The results demonstrate great capability of compressed sampling for overriding the challenges arising in 3D EIT. (paper)

  4. Indirect measurement of lung density and air volume from electrical impedance tomography (EIT) data.

    Science.gov (United States)

    Nebuya, Satoru; Mills, Gary H; Milnes, Peter; Brown, Brian H

    2011-12-01

    This paper describes a method for estimating lung density, air volume and changes in fluid content from a non-invasive measurement of the electrical resistivity of the lungs. Resistivity in Ω m was found by fitting measured electrical impedance tomography (EIT) data to a finite difference model of the thorax. Lung density was determined by comparing the resistivity of the lungs, measured at a relatively high frequency, with values predicted from a published model of lung structure. Lung air volume can then be calculated if total lung weight is also known. Temporal changes in lung fluid content will produce proportional changes in lung density. The method was implemented on EIT data, collected using eight electrodes placed in a single plane around the thorax, from 46 adult male subjects and 36 adult female subjects. Mean lung densities (±SD) of 246 ± 67 and 239 ± 64 kg m(-3), respectively, were obtained. In seven adult male subjects estimates of 1.68 ± 0.30, 3.42 ± 0.49 and 4.40 ± 0.53 l in residual volume, functional residual capacity and vital capacity, respectively, were obtained. Sources of error are discussed. It is concluded that absolute differences in lung density of about 30% and changes over time of less than 30% should be detected using the current technology in normal subjects. These changes would result from approximately 300 ml increase in lung fluid. The method proposed could be used for non-invasive monitoring of total lung air and fluid content in normal subjects but needs to be assessed in patients with lung disease.

  5. Body composition measures of obese adolescents by the deuterium oxide dilution method and by bioelectrical impedance

    Directory of Open Access Journals (Sweden)

    C.M.M. Resende

    2011-11-01

    Full Text Available The objectives of the present study were to describe and compare the body composition variables determined by bioelectrical impedance (BIA and the deuterium dilution method (DDM, to identify possible correlations and agreement between the two methods, and to construct a linear regression model including anthropometric measures. Obese adolescents were evaluated by anthropometric measures, and body composition was assessed by BIA and DDM. Forty obese adolescents were included in the study. Comparison of the mean values for the following variables: fat body mass (FM; kg, fat-free mass (FFM; kg, and total body water (TBW; % determined by DDM and by BIA revealed significant differences. BIA overestimated FFM and TBW and underestimated FM. When compared with data provided by DDM, the BIA data presented a significant correlation with FFM (r = 0.89; P < 0.001, FM (r = 0.93; P < 0.001 and TBW (r = 0.62; P < 0.001. The Bland-Altman plot showed no agreement for FFM, FM or TBW between data provided by BIA and DDM. The linear regression models proposed in our study with respect to FFM, FM, and TBW were well adjusted. FFM obtained by DDM = 0.842 x FFM obtained by BIA. FM obtained by DDM = 0.855 x FM obtained by BIA + 0.152 x weight (kg. TBW obtained by DDM = 0.813 x TBW obtained by BIA. The body composition results of obese adolescents determined by DDM can be predicted by using the measures provided by BIA through a regression equation.

  6. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Science.gov (United States)

    Voutta, R.; Gerstl, S.; Casalbuoni, S.; Grau, A. W.; Holubek, T.; Saez de Jauregui, D.; Bartolini, R.; Cox, M. P.; Longhi, E. C.; Rehm, G.; Schouten, J. C.; Walker, R. P.; Migliorati, M.; Spataro, B.

    2016-05-01

    The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG) has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS). In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014)]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  7. Cold vacuum chamber for diagnostics: Analysis of the measurements at the Diamond Light Source and impedance bench measurements

    Directory of Open Access Journals (Sweden)

    R. Voutta

    2016-05-01

    Full Text Available The beam heat load is an important input parameter needed for the cryogenic design of superconducting insertion devices. Theoretical models taking into account the different heating mechanisms of an electron beam to a cold bore predict smaller values than the ones measured with several superconducting insertion devices installed in different electron storage rings. In order to measure and possibly understand the beam heat load to a cold bore, a cold vacuum chamber for diagnostics (COLDDIAG has been built. COLDDIAG is equipped with temperature sensors, pressure gauges, mass spectrometers as well as retarding field analyzers which allow to measure the beam heat load, total pressure, and gas content as well as the flux of particles hitting the chamber walls. COLDDIAG was installed in a straight section of the Diamond Light Source (DLS. In a previous paper the experimental equipment as well as the installation of COLDDIAG in the DLS are described [S. Gerstl et al., Phys. Rev. ST Accel. Beams 17, 103201 (2014]. In this paper we present an overview of all the measurements performed with COLDDIAG at the DLS and their detailed analysis, as well as impedance bench measurements of the cold beam vacuum chamber performed at the Karlsruhe Institute of Technology after removal from the DLS. Relevant conclusions for the cryogenic design of superconducting insertion devices are drawn from the obtained results.

  8. A cell impedance measurement device for the cytotoxicity assay dependent on the velocity of supplied toxic fluid

    Science.gov (United States)

    Kang, Yoon-Tae; Kim, Min-Ji; Cho, Young-Ho

    2018-04-01

    We present a cell impedance measurement chip capable of characterizing the toxic response of cells depending on the velocity of the supplied toxic fluid. Previous impedance-based devices using a single open-top chamber have been limited to maintaining a constant supply velocity, and devices with a single closed-top chamber present difficulties in simultaneous cytotoxicity assay for varying levels of supply velocities. The present device, capable of generating constant and multiple levels of toxic fluid velocity simultaneously within a single stepwise microchannel, performs a cytotoxicity assay dependent on toxic fluid velocity, in order to find the effective velocity of toxic fluid to cells for maximizing the cytotoxic effect. We analyze the cellular toxic response of 5% ethanol media supplied to cancer cells within a toxic fluid velocity range of 0-8.3 mm s-1. We observe the velocity-dependent cell detachment rate, impedance, and death rate. We find that the cell detachment rate decreased suddenly to 2.4% at a velocity of 4.4 mm s-1, and that the change rates of cell resistance and cell capacitance showed steep decreases to 8% and 41%, respectively, at a velocity of 5.7 mm s-1. The cell death rate and impedance fell steeply to 32% at a velocity of 5.7 mm s-1. We conclude that: (1) the present device is useful in deciding on the toxic fluid velocity effective to cytotoxicity assay, since the cellular toxic response is dependent on the velocity of toxic fluid, and; (2) the cell impedance analysis facilitates a finer cellular response analysis, showing better correlation with the cell death rate, compared to conventional visual observation. The present device, capable of performing the combinational analysis of toxic fluid velocity and cell impedance, has potential for application to the fine cellular toxicity assay of drugs with proper toxic fluid velocity.

  9. Method, system and computer-readable media for measuring impedance of an energy storage device

    Science.gov (United States)

    Morrison, John L.; Morrison, William H.; Christophersen, Jon P.; Motloch, Chester G.

    2016-01-26

    Real-time battery impedance spectrum is acquired using a one-time record. Fast Summation Transformation (FST) is a parallel method of acquiring a real-time battery impedance spectrum using a one-time record that enables battery diagnostics. An excitation current to a battery is a sum of equal amplitude sine waves of frequencies that are octave harmonics spread over a range of interest. A sample frequency is also octave and harmonically related to all frequencies in the sum. A time profile of this sampled signal has a duration that is a few periods of the lowest frequency. A voltage response of the battery, average deleted, is an impedance of the battery in a time domain. Since the excitation frequencies are known and octave and harmonically related, a simple algorithm, FST, processes the time profile by rectifying relative to sine and cosine of each frequency. Another algorithm yields real and imaginary components for each frequency.

  10. Beam Measurements of the Longitudinal impedance of the CERN Super Proton Synchrotron

    CERN Document Server

    AUTHOR|(CDS)2090034; Petrache, Costel

    One of the main challenges of future physics projects based on particle accelerators is the need for high intensity beams. However, collective effects are a major limitation which can deteriorate the beam quality or limit the maximum intensity due to losses. The CERN SPS, which is the last injector for the LHC, is currently unable to deliver the beams required for future projects due to longitudinal instabilities. The numerous devices in the machine (accelerating RF cavities, injection and extraction magnets, vacuum flanges. etc.) lead to variations in the geometry and material of the chamber through which the beam is travelling. The electromagnetic interaction within the beam (space charge) and of the beam with its environment are described by a coupling impedance which affects the motion of the particles and leads to instabilities for high beam intensities. Consequently, the critical impedance sources should be identified and solutions assessed. To have a reliable impedance model of an accelerator, the...

  11. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children.

    Science.gov (United States)

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom scores and individual symptom scores correlate with outcomes in esophageal multichannel intraluminal impedance-pH monitoring. A total of 26 patients with gastroesophageal reflux disease-associated symptoms, aged 0-2 years, for whom both esophageal multichannel intraluminal impedance-pH monitoring and Gastroesophageal reflux disease Assessment Symptom Questionnaire survey results were available were included in the study. Gastroesophageal reflux disease Assessment Symptom Questionnaire score data were collected from a 7-day recall of parent's responses about the frequency and severity of gastroesophageal reflux disease symptoms, which determined the individual symptom scores. The composite symptom scores is the sum of all individual symptom scores. Multichannel intraluminal impedance-pH study results were compared to Gastroesophageal reflux disease Assessment Symptom Questionnaire data using Pearson correlation. Among 26 patients, a total number of 2817 (1700 acid and 1117 non-acid) reflux episodes and 845 clinical reflux behaviors were recorded. There were significant correlations between the reflux index and the individual symptom scores for coughing/gagging/choking (r 2 = 0.2842, p = 0.005), the impedance score and individual symptom scores for coughing/gagging/choking (r 2 = 0.2482, p = 0.009), the reflux symptom index for acid reflux-related coughing/gagging/choking and the individual symptom scores for coughing/gagging/choking (r 2 = 0.1900, p = 0.026), the impedance score and

  12. Validity of a new abdominal bioelectrical impedance device to measure abdominal and visceral fat: comparison with MRI

    OpenAIRE

    Browning, Lucy M; Mugridge, Owen; Chatfield, Mark; Dixon, Adrian; Aitken, Sri; Joubert, Ilse; Prentice, Andrew M.; Jebb, Susan A

    2010-01-01

    Abdominal fat, and in particular, visceral adipose tissue (VAT), is the critical fat depot associated with metabolic aberrations. At present VAT can only be accurately measured by computed tomography (CT) or magnetic resonance imaging (MRI). This study was designed to compare a new abdominal bioelectrical impedance device against total abdominal adipose tissue (TAAT) and VAT area measurements made from an abdominal MRI scan, and to assess it’s reliability and accuracy.

  13. Electrical conductivity and transport properties of cement-based materials measured by impedance spectroscopy

    Science.gov (United States)

    Shane, John David

    The use of Impedance Spectroscopy (IS) as a tool to evaluate the electrical and transport properties of cement-based materials was critically evaluated. Emphasis was placed on determining the efficacy of IS by applying it as a tool to investigate several families of cement-based materials. Also, the functional aspects of electroding and null corrections were also addressed. The technique was found to be advantageous for these analyses, especially as a non-destructive, in-situ, rapid test. Moreover, key insights were gained into several cement-based systems (e.g., cement mortars and oil-well grouts) as well as the effect that certain testing techniques can have on materials (e.g., the rapid chloride permeability test). However, some limitations of IS were identified. For instance, improper electroding of samples can lead to erroneous results and incorrect interpretations for both two-point and multi-point measurements. This is an area of great importance, but it has received very little attention in the literature. Although the analysis of cement/electrode techniques is in its infancy, much progress was made in gaining a full understand of how to properly and reliably connect electrodes to cement-based materials. Through the application of IS to materials such as oil-well grouts, cement mortars and concretes, a great deal of valuable information about the effectiveness of IS has been gained. Oil-well cementing is somewhat limited by the inability to make measurements in the well-bore. By applying IS to oil-well grouts in a laboratory environment, it was demonstrated that IS is a viable technique with which to test the electrical and transport properties of these materials in-situ. Also, IS was shown to have the ability to measure the electrical conductivity of cement mortars with such accuracy, that very subtle changes in properties can be monitored and quantified. Through the use of IS and theoretical models, the complex interplay between the interfacial transition

  14. A comparison of systolic time intervals measured by impedance cardiography and carotid pulse tracing

    DEFF Research Database (Denmark)

    Mehlsen, J; Bonde, J; Rehling, Michael

    1990-01-01

    The purpose of this study was to compare the systolic time intervals (STI) obtained by impedance cardiography and by the conventional carotid technique. This comparison was done with respect to: 1) correlations between variables obtained by the two methods, 2) ability to reflect drug-induced chan......The purpose of this study was to compare the systolic time intervals (STI) obtained by impedance cardiography and by the conventional carotid technique. This comparison was done with respect to: 1) correlations between variables obtained by the two methods, 2) ability to reflect drug...

  15. Increased abdominal fat levels measured by bioelectrical impedance are associated with histological lesions of nonalcoholic steatohepatitis.

    Science.gov (United States)

    Margariti, Aikaterini; Kontogianni, Meropi D; Tileli, Nafsika; Georgoulis, Michael; Deutsch, Melanie; Zafeiropoulou, Rodessa; Tiniakos, Dina; Manios, Yannis; Pectasides, Dimitrios; Papatheodoridis, George V

    2015-08-01

    Abdominal fat is considered to play an important role in nonalcoholic fatty liver disease (NAFLD), although it is not adequately studied because abdominal fat levels cannot be estimated easily. In this study, associations between abdominal obesity, as assessed by abdominal bioelectrical impedance analysis (BIA), and the characteristics of patients with NAFLD were explored. Seventy-four consecutive NAFLD patients who underwent measurement of abdominal fat levels by BIA were included. Levels of abdominal fat 12.5 or less and more than 12.5 were considered to be average and increased, respectively. The mean±SD BMI was 30±4 kg/m and the mean abdominal fat levels were 16±5, whereas 26% of patients had average abdominal fat levels. Patients with average compared with those with increased abdominal fat levels were more frequently women (50 vs. 12%, P=0.001), had lower BMI (27±3 vs. 31±4 kg/m, Pabdominal fat levels (78 vs. 38%, P=0.030) and in patients with BMI 30 or more compared with less than 30 kg/m (87 vs. 48%, P=0.033), but similar in patients with increased or normal waist circumference (67 vs. 56%, P=0.693). Average levels of abdominal fat, as assessed by abdominal BIA, are mainly present in female patients with NAFLD and are associated with a lower degree of insulin resistance. Increased abdominal fat as assessed by BIA and obesity seem to represent strong risk factors for histological steatohepatitis.

  16. Validation of the force and frequency characteristics of the activator adjusting instrument: effectiveness as a mechanical impedance measurement tool.

    Science.gov (United States)

    Keller, T S; Colloca, C J; Fuhr, A W

    1999-02-01

    To determine the dynamic force-time and force-frequency characteristics of the Activator Adjusting Instrument and to validate its effectiveness as a mechanical impedance measurement device; in addition, to refine or optimize the force-frequency characteristics of the Activator Adjusting Instrument to provide enhanced dynamic structural measurement reliability and accuracy. An idealized test structure consisting of a rectangular steel beam with a static stiffness similar to that of the human thoracolumbar spine was used for validation of a method to determine the dynamic mechanical response of the spine. The Activator Adjusting Instrument equipped with a load cell and accelerometer was used to measure forces and accelerations during mechanical excitation of the steel beam. Driving point and transfer mechanical impedance and resonant frequency of the beam were determined by use of a frequency spectrum analysis for different force settings, stylus masses, and stylus tips. Results were compared with beam theory and transfer impedance measurements obtained by use of a commercial electronic PCB impact hammer. The Activator Adjusting Instrument imparted a very complex dynamic impact comprising an initial high force (116 to 140 N), short duration pulse (analysis of the Activator Adjusting Instrument impulse indicated that the Activator Adjusting Instrument has a variable force spectrum and delivers its peak energy at a frequency of 20 Hz. Added masses and different durometer stylus tips had very little influence on the Activator Adjusting Instrument force spectrum. The resonant frequency of the beam was accurately predicted by both the Activator Adjusting Instrument and electronic PCB impact hammer, but variations in the magnitude of the driving point impedance at the resonant frequency were high (67%) compared with the transfer impedance measurements obtained with the electronic PCB impact hammer, which had a more uniform force spectrum and was more repeatable (frequency

  17. Evaluation of the usefulness of visceral fat area measurement by the bioelectrical impedance method during workplace health screening

    International Nuclear Information System (INIS)

    Igarashi, Chiyo

    2008-01-01

    In the field of occupational health, health guidance concerning obesity is often conducted in order to prevent lifestyle-related diseases. With recent awareness of the concept of metabolic syndrome, measurement of the visceral fat area (VFA) by CT has been useful for health guidance, but it is difficult in workplace health screening. Presently, the BMI (Body Mass Index), body fat percentage measured by the bioelectrical impedance method, and waist girth at the umbilical level (abdominal girth) are practical indices of obesity used in such health screening. In this study, VAF was measured in 590 clerical or sales workers in the manufacturing industry using a body fat meter capable of a visceral fat measurement by the bioelectrical impedance method. The relationship of this value to the results of biochemical tests and lifestyle was then evaluated using analysis of covariance structures. Analysis indicated that the risk of lifestyle-related disease was closely related to the degree of obesity. Among indices of the degree of obesity, VFA was more closely related than BMI or body fat percentage, and only slightly less closely related than abdominal girth to the risk of lifestyle-related diseases. Since VFA is effective in screening for latent obesity, health guidance based on digital data, and the subjects' body imaging, its measurement by the bioelectrical impedance method is considered useful for workplace health management. (author)

  18. Inhibition of neuronal cell–cell adhesion measured by the microscopic aggregation assay and impedance sensing

    NARCIS (Netherlands)

    Wiertz, Remy; Marani, Enrico; Rutten, Wim

    2010-01-01

    Microscopic aggregation assay and impedance sensing (IS) were used to monitor a change in in vitro neuron–neuron adhesion in response to blocking of cell adhesion molecules. By blocking neuron–neuron adhesion, migration and aggregation of neuronal cells can be inhibited. This leads to better control

  19. Measuring body composition in dogs using multifrequency bioelectrical impedance analysis and dual energy X-ray absorptiometry.

    Science.gov (United States)

    Rae, L S; Vankan, D M; Rand, J S; Flickinger, E A; Ward, L C

    2016-06-01

    Thirty-five healthy, neutered, mixed breed dogs were used to determine the ability of multifrequency bioelectrical impedance analysis (MFBIA) to predict accurately fat-free mass (FFM) in dogs using dual energy X-ray absorptiometry (DXA)-measured FFM as reference. A second aim was to compare MFBIA predictions with morphometric predictions. MFBIA-based predictors provided an accurate measure of FFM, within 1.5% when compared to DXA-derived FFM, in normal weight dogs. FFM estimates were most highly correlated with DXA-measured FFM when the prediction equation included resistance quotient, bodyweight, and body condition score. At the population level, the inclusion of impedance as a predictor variable did not add substantially to the predictive power achieved with morphometric variables alone; in individual dogs, impedance predictors were more valuable than morphometric predictors. These results indicate that, following further validation, MFBIA could provide a useful tool in clinical practice to objectively measure FFM in canine patients and help improve compliance with prevention and treatment programs for obesity in dogs. Copyright © 2016. Published by Elsevier Ltd.

  20. Studies of Corrosion of Cladding Materials in Simulated BWR-environment Using Impedance Measurements. Part I: Measurements in the Pre-transition Region

    International Nuclear Information System (INIS)

    Forsberg, Stefan; Ahlberg, Elisabet; Andersson, Ulf

    2004-09-01

    The corrosion of three Zircaloy 2 cladding materials, LK2, LK2+ and LK3, have been studied in-situ in an autoclave using electrochemical impedance spectroscopy. Measurements were performed in simulated BWR water at temperatures up to 288 deg C. The impedance spectra were successfully modelled using equivalent circuits. When the oxide grew thicker during the experiments, a change-over from one to two time constants was seen, showing that a layered structure was formed. Oxide thickness, oxide conductivity and effective donor density were evaluated from the impedance data. The calculated oxide thickness at the end of the experiments was consistent with the value obtained from SEM. It was shown that the difference in oxide growth rate between the investigated materials is small in the pre-transition region. The effective donor density, which is a measure of electronic conductivity, was found to be lower for the LK3 material compared to the other two materials

  1. Recommendations for measurement of tumour vascularity with positron emission tomography in early phase clinical trials

    International Nuclear Information System (INIS)

    Aboagye, Eric O.; Kenny, Laura M.; Myers, Melvyn; Gilbert, Fiona J.; Fleming, Ian N.; Beer, Ambros J.; Cunningham, Vincent J.; Marsden, Paul K.; Visvikis, Dimitris; Gee, Antony D.; Groves, Ashley M.; Cook, Gary J.; Kinahan, Paul E.; Clarke, Larry

    2012-01-01

    The evaluation of drug pharmacodynamics and early tumour response are integral to current clinical trials of novel cancer therapeutics to explain or predict long term clinical benefit or to confirm dose selection. Tumour vascularity assessment by positron emission tomography could be viewed as a generic pharmacodynamic endpoint or tool for monitoring response to treatment. This review discusses methods for semi-quantitative and quantitative assessment of tumour vascularity. The radioligands and radiotracers range from direct physiological functional tracers like [ 15 O]-water to macromolecular probes targeting integrin receptors expressed on neovasculature. Finally we make recommendations on ways to incorporate such measurements of tumour vascularity into early clinical trials of novel therapeutics. (orig.)

  2. Correlation of Gastroesophageal reflux disease Assessment Symptom Questionnaire to impedance-pH measurements in children

    OpenAIRE

    Prachuapthunyachart, Sittichoke; Jarasvaraparn, Chaowapong; Gremse, David A

    2017-01-01

    Background: Esophageal multichannel intraluminal impedance-pH monitoring has become one of the preferred tests to correlate observed reflux-like behaviors with esophageal reflux events. The Gastroesophageal reflux disease Assessment Symptom Questionnaire is a validated tool used to distinguish infants with gastroesophageal reflux disease from healthy children. The aim of this study was to determine whether the Gastroesophageal reflux disease Assessment Symptom Questionnaire composite symptom ...

  3. Stroke Volume during Mueller Maneuver Measured by Impedance Cardiography in Patients with Mitral Regurgitation

    Czech Academy of Sciences Publication Activity Database

    Viščor, Ivo; Jurák, Pavel; Vondra, Vlastimil; Halámek, Josef; Leinveber, Pavel

    2009-01-01

    Roč. 36, - (2009), s. 749-751 ISSN 0276-6574 R&D Projects: GA AV ČR IAA200650801; GA ČR GP102/07/P425 Institutional research plan: CEZ:AV0Z20650511 Keywords : Mueller maneuver * impedance cardiography * congestive heart failure Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering http://cinc.mit.edu/archives/2009/pdf/0749.pdf

  4. NICKEL HYDROXIDE FILMS IN CONTACT WITH AN ELECTROACTIVE SOLUTION. A STUDY EMPLOYING ELECTROCHEMICAL IMPEDANCE MEASUREMENTS

    OpenAIRE

    RICARDO TUCCERI

    2018-01-01

    The deactivation of nickel hydroxide films after prolonged storage times without use was studied. This study was carried out in the context of the Rotating Disc Electrode Voltammetry (RDEV) and Electrochemical Impedance Spectroscopy (EIS) when the nickel hydroxide film contacts an electroactive solution and a redox reaction occurs at the Au-Ni(OH)2|electrolyte interface. Deferasirox (4-(3,5-bis(2- hydroxyphenyl)-1,2,4-triazol-1-yl) benzoic acid) was employed as redox species in solution. Limi...

  5. The application of impedance measurement to assess biofilm development on technical materials used for water supply system construction

    Science.gov (United States)

    Wolf, Mirela; Traczewska, Teodora; Grzebyk, Tomasz

    2017-11-01

    The lack of biological stability of water which is introduced into the network, leads primarily to its secondary contamination during transport to the consumer. The water that is biologically unstable creates ideal conditions for colonization of the inner surface of pipelines by microorganisms and adhesion of their products (biocorrosion). The studies was conducted using the identified microorganisms isolated from the water supply network which accounted inocula in continuous culture of biofilm in CDC reactor. As a result of studies it was revealed the presence of biofilm formed on different materials polyethylene, polypropylene, polyvinyl chloride, polybutylene. Microbiological biodiversity of organisms inhabiting a biofilm of the diversity of nucleic acids was used. It was observed the amount of the psychrophilic bacteria oscillation in the effluent from the reactor. It was also determined the affinity of various bacteria to the plastic through adhesion measurement using impedance spectroscopy. For impedance measurements apparatus SIGNAL RECOVERY 7280 DSP LOCK-IN AMPLIFIER was used, recording impedance components (real and imaginary). The results will allow for the creation of biosensor systems that can be used in predicting health risks in connection with drinking water and taking corrective actions.

  6. The application of impedance measurement to assess biofilm development on technical materials used for water supply system construction

    Directory of Open Access Journals (Sweden)

    Wolf Mirela

    2017-01-01

    Full Text Available The lack of biological stability of water which is introduced into the network, leads primarily to its secondary contamination during transport to the consumer. The water that is biologically unstable creates ideal conditions for colonization of the inner surface of pipelines by microorganisms and adhesion of their products (biocorrosion. The studies was conducted using the identified microorganisms isolated from the water supply network which accounted inocula in continuous culture of biofilm in CDC reactor. As a result of studies it was revealed the presence of biofilm formed on different materials polyethylene, polypropylene, polyvinyl chloride, polybutylene. Microbiological biodiversity of organisms inhabiting a biofilm of the diversity of nucleic acids was used. It was observed the amount of the psychrophilic bacteria oscillation in the effluent from the reactor. It was also determined the affinity of various bacteria to the plastic through adhesion measurement using impedance spectroscopy. For impedance measurements apparatus SIGNAL RECOVERY 7280 DSP LOCK-IN AMPLIFIER was used, recording impedance components (real and imaginary. The results will allow for the creation of biosensor systems that can be used in predicting health risks in connection with drinking water and taking corrective actions.

  7. Nonsynchronous Noncommensurate Impedance Transformers

    DEFF Research Database (Denmark)

    Zhurbenko, Vitaliy; Kim, K

    2012-01-01

    Nonsynchronous noncommensurate impedance transformers consist of a combination of two types of transmission lines: transmission lines with a characteristic impedance equal to the impedance of the source, and transmission lines with a characteristic impedance equal to the load. The practical...... advantage of such transformers is that they can be constructed using sections of transmission lines with a limited variety of characteristic impedances. These transformers also provide comparatively compact size in applications where a wide transformation ratio is required. This paper presents the data...... matrix approach and experimentally verified by synthesizing a 12-section nonsynchronous noncommensurate impedance transformer. The measured characteristics of the transformer are compared to the characteristics of a conventional tapered line transformer....

  8. RHIC injection kicker impedance

    International Nuclear Information System (INIS)

    Mane, V.; Peggs, S.; Trbojevic, D.; Zhang, W.

    1995-01-01

    The longitudinal impedance of the RHIC injection kicker is measured using the wire method up to a frequency of 3 GHz. The mismatch between the 50 ohm cable and the wire and pipe system is calibrated using the TRL calibration algorithm. Various methods of reducing the impedance, such as coated ceramic pipe and copper strips are investigated

  9. Impedance measurements on oxide films on aluminium obtained by pulsed tensions

    Energy Technology Data Exchange (ETDEWEB)

    Belmokre, K. [Lab. of Applied Chemical, Dept. of Chemie, Skikda University, BP 26 - 21000 Skikda (Algeria); Azzouz, N. [Dept. of Industrial Chemie, Jijel University Center, 18000 Jijel (Algeria); Hannani, A. [Lab. Electrochem. Corros. Institute of Chemical USTHB Alger (Algeria); Pagetti, J. [Lab. LCMI, Franche-Comte - University UFR Sciences and Technical 16, Gray street - 25030 Besancon Cedex (France)

    2003-01-01

    We have performed this study on oxide films sealed or not in boiling water. The films are first obtained on type 1050 A aluminium substrate by pulsed tensions anodizing technique, in a sulfuric acid solution. Afterwards the, Electrochemical Impedance Spectroscopy (EIS) is employed to appreciate the films behaviour in a neutral solution of 3.5% K{sub 2}SO{sub 4}, in which the interface processes interest only the ageing phenomenon of the oxide films and not their corrosion. We have also attempted a correlation between pulse parameters of anodization and the electrical parameters characterizing these films. The sealing influence on ageing has been studied as well. For all films, ageing is appreciated using impedance diagrams evolution versus time. The results show: - the existence of two capacitive loops confirming the presence of two oxide layers characteristic of oxide films obtained in a sulfuric acid medium. The first loop, at high frequencies, is related to the external porous layer and the second one, at lower frequencies, is related to the internal barrier layer. - the thickness of the barrier layer varies between 25 and 40 nm in relation with the electrical pulse parameters. - the sealing acts favorably against anodic oxide films ageing. (Abstract Copyright [2003], Wiley Periodicals, Inc.)

  10. Impedance spectroscopy of PZT ceramics--measuring diffusion coefficients, mixed conduction, and Pb loss.

    Science.gov (United States)

    Donnelly, Niall J; Randall, Clive A

    2012-09-01

    Sintering of lead zirconate titanate (PZT) at high temperatures results in loss of Pb unless an ambient Pb activity is maintained. The tell-tale sign of Pb loss is an increased conductivity, usually manifested in unacceptably high values of tanδ. The conductivity is caused by oxygen vacancies and/or electron holes which are a byproduct of Pb evaporation. In the first part of this paper, it is shown how impedance spectroscopy can be used to separate ionic and electronic conductivity in a properly designed sample by selection of appropriate boundary conditions. Subsequently, impedance is used to probe defect concentrations in PZT during prolonged annealing at 700°C. It is found that oxygen vacancies are generated during annealing in air but the rate of generation actually decreases upon lowering the ambient pO(2). These results are explained by a model of Pb evaporation which, in this case, leads predominantly to oxygen vacancy generation. In principle, this effect could be used to generate a specific vacancy concentration in similar Pb-based oxides.

  11. Passivation of laser-treated nickel aluminum bronze as measured by electrochemical impedance spectroscopy

    International Nuclear Information System (INIS)

    Klassen, R.D.; Hyatt, C.V.; Roberge, P.R.

    2000-01-01

    Electrochemical impedance spectroscopy was used to assess the corrosion behavior of the weld zones and surface conditions of a laser-clad nickel aluminum bronze immersed in a 3.5% neutral saline solution. The zones and conditions examined included: (i) as-cast base material; (ii) laser-clad material with the high temperature oxide from welding intact; (iii) polished laser-clad material and (iv) specimens representative of just the as-deposited and reheated zones of the laser-clad surface. A pseudo steady-state level of passivation was reached in all the samples within 40 hours. The reheated zone passivated more slowly than the as-deposited region and both weld zones passivated more quickly than the base material. Electrochemical impedance data illustrated a transition during the passivation process of the polished specimens that is consistent with the development of a film layer that restricted mass transfer. The welding oxide from the laser treatment immediately behaved as a passivation film that was indistinguishable from that which eventually develops on polished specimens. (author)

  12. Impedance Scaling and Impedance Control

    International Nuclear Information System (INIS)

    Chou, W.; Griffin, J.

    1997-06-01

    When a machine becomes really large, such as the Very Large Hadron Collider (VLHC), of which the circumference could reach the order of megameters, beam instability could be an essential bottleneck. This paper studies the scaling of the instability threshold vs. machine size when the coupling impedance scales in a ''normal'' way. It is shown that the beam would be intrinsically unstable for the VLHC. As a possible solution to this problem, it is proposed to introduce local impedance inserts for controlling the machine impedance. In the longitudinal plane, this could be done by using a heavily detuned rf cavity (e.g., a biconical structure), which could provide large imaginary impedance with the right sign (i.e., inductive or capacitive) while keeping the real part small. In the transverse direction, a carefully designed variation of the cross section of a beam pipe could generate negative impedance that would partially compensate the transverse impedance in one plane

  13. Measures of total stress-induced blood pressure responses are associated with vascular damage.

    Science.gov (United States)

    Nazzaro, Pietro; Seccia, Teresa; Vulpis, Vito; Schirosi, Gabriella; Serio, Gabriella; Battista, Loredana; Pirrelli, Anna

    2005-09-01

    The role of cardiovascular reactivity to study hypertension, and the assessment methods, are still controversial. We aimed to verify the association of hypertension and vascular damage with several measures of cardiovascular response. We studied 40 patients with normal-high (132 +/- 1/87 +/- 1 mm Hg) blood pressure (Group 1) and 80 untreated hypertensive subjects. Postischemic forearm vascular resistance (mFVR) served to differentiate hypertensive subjects (142 +/- 2/92 +/- 1 mm Hg v 143 +/- 2/94 +/- 2 mm Hg, P = NS) with a lower (Group 2) and higher (Group 3) hemodynamic index of vascular damage (4.8 +/- .05 v 6.3 +/- .09, P blood pressure, heart rate, forearm blood flow, and vascular resistance. Reactivity measures included: a) change from baseline, b) residualized score, c) cumulative change from baseline and residualized score, and d) total reactivity as area-under-the-curve (AUC), including changes occurring during baseline and recovery phases. The AUC of systolic blood pressure, diastolic blood pressure, and mFVR progressively increased in the groups (P AUC of SBP, DBP, and forearm blood flow and resistance demonstrated the highest (P AUC of SBP (beta = 0.634) and forearm blood flow (beta = -0.337) were predictive (P blood pressure stress response, as AUC, including baseline and recovery phases, was significantly better associated with hypertension and vascular damage than the other reactivity measures studied.

  14. Measurements and removal of substrate effects on the microwave surface impedance of YBCO films on SrTiO{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Pompeo, N [Dipartimento di Fisica ' E Amaldi' and Unita CNISM, Universita Roma Tre, Via dellaVasca Navale 84, 00146 Rome (Italy); Muzzi, L [Dipartimento di Fisica ' E Amaldi' and Unita CNISM, Universita Roma Tre, Via dellaVasca Navale 84, 00146 Rome (Italy); Galluzzi, V [ENEA-Frascati, Via Enrico Fermi 45, 00044 Frascati, Rome (Italy); Marcon, R [Dipartimento di Fisica ' E Amaldi' and Unita CNISM, Universita Roma Tre, Via dellaVasca Navale 84, 00146 Rome (Italy); Silva, E [Dipartimento di Fisica ' E Amaldi' and Unita CNISM, Universita Roma Tre, Via dellaVasca Navale 84, 00146 Rome (Italy)

    2007-10-15

    We reconsider the problem of the measurements of the microwave complex surface impedance in thin superconducting films deposited on SrTiO{sub 3} substrates. We perform measurements of the complex surface impedance Z{sub s}' = R{sub s}'+i{delta}X{sub s}' of thin YBa{sub 2}Cu{sub 3}O{sub 7-{delta}} films deposited by laser ablation on SrTiO{sub 3} substrates. The typical oscillations due to the strong temperature variation of the SrTiO{sub 3} permittivity are confirmed in R{sub s}' and observed in {delta}X{sub s}'. The effects of the SrTiO{sub 3} substrate are evident even well below the superconducting transition temperature of YBa{sub 2}Cu{sub 3}O{sub 7-{delta}}. Similarly to previous works, we describe the overall response in terms of impedance transformations. We extend the known results by (i) considering the measurements of the imaginary part (ii) comparing the measurements to the absolute dc resistivity measured on the same sample, and (iii) suggesting a method for measuring the intrinsic thin film surface impedance by adjusting the substrate impedance. To demonstrate the feasibility of microwave measurements of intrinsic properties of films grown onto SrTiO{sub 3} substrates, we check the proposed method by measuring the field dependent surface impedance before and after removal of the substrate resonance.

  15. Percentiles of body fat measured by bioelectrical impedance in children and adolescents from Bogotá (Colombia): the FUPRECOL study.

    Science.gov (United States)

    Escobar-Cardozo, Germán D; Correa-Bautista, Jorge E; González-Jiménez, Emilio; Schmidt-RioValle, Jacqueline; Ramírez-Vélez, Robinson

    2016-04-01

    The analysis of body composition is a fundamental part of nutritional status assessment. The objective of this study was to establish body fat percentiles by bioelectrical impedance in children and adolescents from Bogotá (Colombia) who were part of the FUPRECOL study (Asociación de la Fuerza Prensil con Manifestaciones Tempranas de Riesgo Cardiovascular en Niños y Adolescentes Colombianos - Association between prehensile force and early signs of cardiovascular risk in Colombian children and adolescents). This was a cross-sectional study conducted among 5850 students aged 9-17.9 years old from Bogotá (Colombia). Body fat percentage was measured using foot-to-foot bioelectrical impedance (Tanita®, BF-689), by age and gender. Weight, height, waist circumference, and hip circumference were measured, and sexual maturity was self-staged. Percentiles (P3, P10, P25, P50, P75, P90 and P97) and centile curves were estimated using the LMS method (L [BoxCox curve], M [median curve] and S [variation coefficient curve]), by age and gender. Subjects included were 2526 children and 3324 adolescents. Body fat percentages and centile curves by age and gender were established. For most age groups, values resulted higher among girls than boys. Participants with values above P90 were considered to have a high cardiovascular risk due to excess fat (boys > 23.428.3, girls > 31.0-34.1). Body fat percentage percentiles measured using bioelectrical impedance by age and gender are presented here and may be used as reference to assess nutritional status and to predict cardiovascular risk due to excess fat at an early age. Sociedad Argentina de Pediatría.

  16. A pneumatic bellows-driven setup for controlled-distance electrochemical impedance measurements of Zircaloy-2 in simulated BWR conditions

    International Nuclear Information System (INIS)

    Arilahti, E.; Bojinov, M.; Hansson-Lyyra, L.

    2004-01-01

    This paper describes a novel pneumatic bellows-driven arrangement designed for controlled distance electrochemistry (CDE) measurements. The feasibility of the new arrangement has been verified by performing contact electric impedance measurements to study corrosion of Zircaloy-2 in a re-circulation loop simulating the BWR conditions. Until now, the measurements have been carried out using a step-motor driven controlled-distance electrochemistry (CDE) arrangement. The electrical and electrochemical properties of the pre transition oxide on Zircaloy-2 determined from these measurements were in good agreement with those estimated from measurements with a step-motor driven CDE. Furthermore, the results indicate that the bellows-driven CDE device is less sensitive to the contact pressure variation than the step-motor driven arrangement. This property combined with the bellows driven displacement mechanism provides a clear advantage for future in-core corrosion studies of fuel cladding materials. (Author)

  17. Ventilation distribution in rats: Part I - The effect of gas composition as measured with electrical impedance tomography

    Directory of Open Access Journals (Sweden)

    Dunster Kimble R

    2012-09-01

    Full Text Available Abstract The measurement of ventilation distribution is currently performed using inhaled tracer gases for multiple breath inhalation studies or imaging techniques to quantify spatial gas distribution. Most tracer gases used for these studies have properties different from that of air. The effect of gas density on regional ventilation distribution has not been studied. This study aimed to measure the effect of gas density on regional ventilation distribution. Methods Ventilation distribution was measured in seven rats using electrical impedance tomography (EIT in supine, prone, left and right lateral positions while being mechanically ventilated with either air, heliox (30% oxygen, 70% helium or sulfur hexafluoride (20% SF6, 20% oxygen, 60% air. The effect of gas density on regional ventilation distribution was assessed. Results Gas density did not impact on regional ventilation distribution. The non-dependent lung was better ventilated in all four body positions. Gas density had no further impact on regional filling characteristics. The filling characteristics followed an anatomical pattern with the anterior and left lung showing a greater impedance change during the initial phase of the inspiration. Conclusion It was shown that gas density did not impact on convection dependent ventilation distribution in rats measured with EIT.

  18. Measurement of Two-Phase Flow Fields by Application of Dynamic Electrical Impedance Imaging

    International Nuclear Information System (INIS)

    Kim, KyungYoun; Kang, Sook In; Kim, Ho Chan; Kim, Sin; Lee, Yoon Joon; Kim, Min Chan; Anghaie, Samim

    2002-01-01

    This study presents a visualization technique for the phase distribution in a two-phase flow field with an electrical impedance imaging technique, which reconstructs the resistivity distribution with electrical responses that are determined by corresponding excitations. Special emphasis is placed on the development of dynamic imaging technique for two-phase system undergoing a rapid transient, which could not be visualized with conventional static imaging techniques. The proposed algorithm treats the image reconstruction problem as a nonlinear state estimation problem and the unknown state (resistivity distribution, i.e. phase distribution) is estimated with the aid of a Kalman filter in a minimum mean square error sense. Several illustrative examples with computer simulations are successfully provided to verify the reconstruction performance of the proposed algorithm. (authors)

  19. Measurements of the loading impedance and field scaling of a cavity ICRF launcher for Big D

    International Nuclear Information System (INIS)

    Rettig, C.; Ryan, P.M.; Hoffman, D.J.

    1985-01-01

    Recently, a new ICRF launcher in the form of a resonant coil cavity has been proposed and analyzed using a convenient two-dimensional model and a Poisson-solver computer code. Here, a physical model of the launcher has been fabricated to test the scaling characteristics of the impedance and relative fields as a function of the physical sizing of the structure. Variable parameters include the antenna-to-plasma distance, the cavity back wall-to-plasma distance, and the antenna cross-sectional shape. Each of these parameters is varied in the interest of optimizing the radiated power for given antenna voltage and current limits. Critical design criterial will be determined from the data. The report consists of 21 viewgraphs

  20. Measurements of the surface impedance and the ac critical field of superconducting thin tin films at 10 GHz

    International Nuclear Information System (INIS)

    Spencer, G.L.

    1976-01-01

    The surface impedances and ac critical fields of superconducting thin tin films were studied. These experiments were performed using a superconducting frequency stabilized microwave cavity of high Q. Measurements of the power losses in the cavity and the center frequency of the cavity were used to determine the surface impedance and the critical field of a thin film sample placed in the cavity. In this case a theoretical treatment based on a model proposed by I.O. Kulik was used to fit the data. The general agreement between the modified Kulik treatment and the data, obtained in this experiment, was substantial. The second method was to modify the thin film data to correspond to a bulk situation. This modification was accomplished by taking into account the measuring techniques used and the geometric consideration inherent in the experiment. The comparison between the modified experimental data and calculations obtained from the Mattis-Bardeen bulk model was generally very good. One aspect of the results which was not explained was the presence of a slight increase in the surface resistance in the vicinity of the transition temperature. The critical field measurements were compared to the (1 - (T/T/sub c/)/sup 1/2) dependence predicted by Bardeen. If it is assumed that substantial microwave heating took place in the sample near T/sub c/, then remarkable agreement with the Bardeen model can be reached

  1. Cerebral blood measurements in cerebral vascular disease: methodological and clinical aspects

    International Nuclear Information System (INIS)

    Fieschi, C.; Lenzi, G.L.

    1982-01-01

    This paper is devoted mainly to studies performed on acute cerebral vascular disease with the invasive techniques for the measurement of regional cerebral blood flow (rCBF). The principles of the rCBF method are outlined and the following techniques are described in detail: xenon-133 inhalation method, xenon-133 intravenous method and emission tomography methods. (C.F.)

  2. Directed weighted network structure analysis of complex impedance measurements for characterizing oil-in-water bubbly flow.

    Science.gov (United States)

    Gao, Zhong-Ke; Dang, Wei-Dong; Xue, Le; Zhang, Shan-Shan

    2017-03-01

    Characterizing the flow structure underlying the evolution of oil-in-water bubbly flow remains a contemporary challenge of great interests and complexity. In particular, the oil droplets dispersing in a water continuum with diverse size make the study of oil-in-water bubbly flow really difficult. To study this issue, we first design a novel complex impedance sensor and systematically conduct vertical oil-water flow experiments. Based on the multivariate complex impedance measurements, we define modalities associated with the spatial transient flow structures and construct modality transition-based network for each flow condition to study the evolution of flow structures. In order to reveal the unique flow structures underlying the oil-in-water bubbly flow, we filter the inferred modality transition-based network by removing the edges with small weight and resulting isolated nodes. Then, the weighted clustering coefficient entropy and weighted average path length are employed for quantitatively assessing the original network and filtered network. The differences in network measures enable to efficiently characterize the evolution of the oil-in-water bubbly flow structures.

  3. Recommendations for measurement of tumour vascularity with positron emission tomography in early phase clinical trials

    Energy Technology Data Exchange (ETDEWEB)

    Aboagye, Eric O.; Kenny, Laura M.; Myers, Melvyn [Imperial College London, Department of Surgery and Cancer, Faculty of Medicine, London (United Kingdom); Gilbert, Fiona J. [University of Cambridge, Radiology Department, Cambridge (United Kingdom); Fleming, Ian N. [University of Aberdeen, NCRI PET Research Network, Aberdeen Bioimaging Centre, Aberdeen (United Kingdom); Beer, Ambros J. [Technische Universitaet Munchen, Klinikum rechts der Isar, Department of Nuclear Medicine, Munich (Germany); Cunningham, Vincent J. [University of Aberdeen, Institute of Medical Sciences, Aberdeen (United Kingdom); Marsden, Paul K. [St. Thomas' Hospital, Division of Imaging Sciences, PET Imaging Centre, London (United Kingdom); Visvikis, Dimitris [INSERM National Institute of Health and Clinical Sciences LaTIM, CHU Morvan, Brest (France); Gee, Antony D. [St. Thomas' Hospital, Division of Imaging Sciences, The Rayne Institute, London (United Kingdom); Groves, Ashley M. [University College London, University College Hospital, Institute of Nuclear Medicine, London (United Kingdom); Cook, Gary J. [St. Thomas' Hospital, KCL Division of Imaging, Sciences and Biomedical Engineering, PET Imaging Centre, London (United Kingdom); Kinahan, Paul E. [University of Washington, 222 Old Fisheries Center (FIS), Box 357987, Seattle, WA (United States); Clarke, Larry [Cancer Imaging Program, Imaging Technology Development Branch, Rockville, MD (United States)

    2012-07-15

    The evaluation of drug pharmacodynamics and early tumour response are integral to current clinical trials of novel cancer therapeutics to explain or predict long term clinical benefit or to confirm dose selection. Tumour vascularity assessment by positron emission tomography could be viewed as a generic pharmacodynamic endpoint or tool for monitoring response to treatment. This review discusses methods for semi-quantitative and quantitative assessment of tumour vascularity. The radioligands and radiotracers range from direct physiological functional tracers like [{sup 15}O]-water to macromolecular probes targeting integrin receptors expressed on neovasculature. Finally we make recommendations on ways to incorporate such measurements of tumour vascularity into early clinical trials of novel therapeutics. (orig.)

  4. Impedance measurement and modelling of super-capacitors for railway applications

    Energy Technology Data Exchange (ETDEWEB)

    Hammar, A.; Chabas, J. [Societe Nationale des Chemins de fer Francais (SNCF), Dir. de la Recherche, 75 - Paris (France); Coquery, G.; Lallemand, R. [Institut National de Recherche sur les Transports et leur Securite (INRETS), Lab. des Technologies Nouvelles, 94 - Arcueil (France); Rojat, G.; Venet, P. [Lyon-1 Univ. Claude Bernard, CEGELY, 69 - Villeurbanne (France)

    2004-07-01

    Railways and electrical traction systems require high power rates to achieve their operating performances. Systems of power supply based on super-capacitors should offer high power density along with good energy efficiency and expected operating safety. We investigate general behaviours of super-capacitors with two powerful methods of analysis. The first is constant charge/discharge current at high level value (500 A), the second is impedance spectroscopy which leads to the acquisition of a set of parameters that are considered sufficient to describe general properties of super-capacitor, in particular the state of health and the available energy in any operating conditions. An electrical circuit model is defined for super-capacitors based on activated carbon and organic electrolyte. It takes into account the dependence of super-capacitor to voltage and current. The mixture of data of the two methods permits to obtain a representative model for power applications. Matlab/Simulink simulations are shown to verify the validity of the model. (authors)

  5. Evaluation of electrical broad bandwidth impedance spectroscopy as a tool for body composition measurement in cows in comparison with body measurements and the deuterium oxide dilution method.

    Science.gov (United States)

    Schäff, C T; Pliquett, U; Tuchscherer, A; Pfuhl, R; Görs, S; Metges, C C; Hammon, H M; Kröger-Koch, C

    2017-05-01

    Body fatness and degree of body fat mobilization in cows vary enormously during their reproduction cycle and influence energy partitioning and metabolic adaptation. The objective of the study was to test bioelectrical impedance spectroscopy (BIS) as a method for predicting fat depot mass (FDM), in living cows. The FDM is defined as the sum of subcutaneous, omental, mesenteric, retroperitoneal, and carcass fat mass. Bioelectrical impedance spectroscopy is compared with the prediction of FDM from the deuterium oxide (DO) dilution method and from body conformation measurements. Charolais × Holstein Friesian (HF; = 18; 30 d in milk) crossbred cows and 2 HF (lactating and nonlactating) cows were assessed by body conformation measurements, BIS, and the DO dilution method. The BCS of cows was a mean of 3.68 (SE 0.64). For the DO dilution method, a bolus of 0.23 g/kg BW DO (60 atom%) was intravenously injected and deuterium (D) enrichment was analyzed in plasma and whey by stabile isotope mass spectrometry, and total body water content was calculated. Impedance measurement was performed using a 4-electrode interface and time domain-based measurement system consisting of a voltage/current converter for applying current stimulus and an amplifier for monitoring voltage across the sensor electrodes. For the BIS, we used complex impedances over three frequency decades that delivers information on intra- and extracellular water and capacity of cell membranes. Impedance data (resistance of extra- and intracellular space, cell membrane capacity, and phase angle) were extracted 1) by simple curve fit to extract the resistance at direct current and high frequency and 2) by using an electrical equivalent circuit. Cows were slaughtered 7 d after BIS and D enrichment measurements and dissected for the measurement of FDM. Multiple linear regression analyses were performed to predict FDM based on data obtained from body conformation measurements, BIS, and D enrichment, and applied

  6. The LEP impedance model

    Energy Technology Data Exchange (ETDEWEB)

    Zotter, B [European Organization for Nuclear Research, Geneva (Switzerland)

    1996-08-01

    This report describes a number of measurements and computations of the impedance of the Large Electron Positron collider LEP at CERN. The work has been performed over several years, together with D. Brandt, K. Cornelis, A. Hofmann, G. Sabbi and many others. The agreement between measurements of single bunch instabilities on the machine and computer simulations is in general excellent and gives confidence in the impedance model used. (author)

  7. Flow-volume loops measured with electrical impedance tomography in pediatric patients with asthma.

    Science.gov (United States)

    Ngo, Chuong; Dippel, Falk; Tenbrock, Klaus; Leonhardt, Steffen; Lehmann, Sylvia

    2018-05-01

    Electrical impedance tomography (EIT) provides information on global and regional ventilation during tidal breathing and mechanical ventilation. During forced expiration maneuvers, the linearity of EIT and spirometric data has been documented in healthy persons. The present study investigates the potential diagnostic use of EIT in pediatric patients with asthma. EIT and spirometry were performed in 58 children with asthma (average age ± SD: 11.86 ± 3.13 years), and 58 healthy controls (average age ± SD: 12.12 ± 2.9 years). The correlation between EIT data and simultaneously acquired spirometric data were tested for FEV 1 , FEV 0.5 , MEF 75 , MEF 50 , and MEF 25 . Binary classification tests were performed for the EIT-derived Tiffeneau index FEV 1 /FVC and the bronchodilator test index ΔFEV 1 . Average flow-volume (FV) loops were generated for patients with pathologic spirometry to demonstrate the feasibility of EIT for graphic diagnosis of asthma. Spirometry and global EIT-based FV loops showed a strong correlation (P  0.9 in FEV 1 and FEV 0.5 ). In all criteria, the binary classification tests yielded high specificity (>93%), a high positive predictive value (≥75%) and a high negative predictive value (>80%), while sensitivity was higher in ΔFEV 1 (86.67%) and lower in FEV 1 /FVC (25% and 35.29%). A typical concave shape of the EIT-derived average FV loops was observed for asthmatic children with improvement after bronchospasmolysis. Global FV loops derived from EIT correlate well with spirometry. Positive bronchospasmolysis can be observed in EIT-derived FV loops. Flow-volume loops originated from EIT have a potential to visualize pulmonary function. © 2018 Wiley Periodicals, Inc.

  8. Impedance measurements on YB/sub 2/Cu/sub 3/O/sub 7-delta) interpretation and trapping parameters

    International Nuclear Information System (INIS)

    Yasmeen, S.; Mohammad, M.; Khan, A.Y.; Subhani, M.S.

    1997-01-01

    Two probe impedance spectroscopic studies were carried out on YBa/sub 2/Cu/sub 3/ O/sub 7-delta/ two different sintering conditions i.e. at before final sintering and at after final sintering. In both condition ac impedance studies were done in the frequency range of 1Hz to 100kHz and at different temperatures from room temperature down to 78K. Measurements were done with contacts opposite side (i.e., ceramic behaves as a resister) as well as on opposite sides (i.e., ceramic behaves as a capacitor). Results were obtained in the form of Nyquist plot. Log, Yi/omega Vs log f plot and Yr/omega Vs log f plot. These plots were explained through equivalent circuits. The bulk resistance Rb, the grain boundary resistance R/sub b/ and grain boundary capacitance C/sub gb/ were obtained through these plots. The ac conductivities were also obtained at all temperatures. The log sigma g Vs log omega (frequency) plots were interpreted invoking the theory of ac conductivity in polycrystalline solids. The trapping parameters (binding energy, the hopping distance etc.) were calculated and interpreted. (author)

  9. The equivalent circuit of single crab muscle fibers as determined by impedance measurements with intracellular electrodes.

    Science.gov (United States)

    Eisenberg, R S

    1967-07-01

    The input impedance of muscle fibers of the crab was determined with microelectrodes over the frequency range 1 cps to 10 kc/sec. Care was taken to analyze, reduce, and correct for capacitive artifact. One dimensional cable theory was used to determine the properties of the equivalent circuit of the membrane admittance, and the errors introduced by the neglect of the three dimensional spread of current are discussed. In seven fibers the equivalent circuit of an element of the membrane admittance must contain a DC path and two capacitances, each in series with a resistance. In two fibers, the element of membrane admittance could be described by one capacitance in parallel with a resistance. In several fibers there was evidence for a third very large capacitance. The values of the elements of the equivalent circuit depend on which of several equivalent circuits is chosen. The circuit (with a minimum number of elements) that was considered most reasonably consistent with the anatomy of the fiber has two branches in parallel: one branch having a resistance R(e) in series with a capacitance C(e); the other branch having a resistance R(b) in series with a parallel combination of a resistance R(m) and a capacitance C(m). The average circuit values (seven fibers) for this model, treating the fiber as a cylinder of sarcolemma without infoldings or tubular invaginations, are R(e) = 21 ohm cm(2); C(e) = 47 microf/cm(2); R(b) = 10.2 ohm cm(2); R(m) = 173 ohm cm(2); C(m) = 9.0 microf/cm(2). The relation of this equivalent circuit and another with a nonminimum number of circuit elements to the fine structure of crab muscle is discussed. In the above equivalent circuit R(m) and C(m) are attributed to the sarcolemma; R(e) and C(e), to the sarcotubular system; and R(b), to the amorphous material found around crab fibers. Estimates of actual surface area of the sarcolemma and sarcotubular system permit the average circuit values to be expressed in terms of unit membrane area. The

  10. Study of colored anodized aluminum with calcon in sulfuric acidic solution using cyclic voltammetry and impedance measurement methods

    Energy Technology Data Exchange (ETDEWEB)

    Norouzi, P.; Ganjali, M.R.; Golmohamaddi, M.; Mousavi, S. [Department of Chemistry, Faculty of Science, University of Tehran, Tehran (Iran); Vatankhah, G. [Iranian Organization for Science and Technology (IROST), Isfahan Center, A5 Ghezelbash Avenue, Tohid Street, Isfahan 8173954541 (Iran)

    2003-04-01

    The effect of coloring condition of Al with Calcon (sodium 2,2'-dihydroxy-azonaphthalene-4-sulfonate), on the corrosion resistance of Al in 0.1 M sulfuric acid solution was studied, using cyclic voltammetry and measurement of impedance noise methods. The changes in the corrosion resistance of colored aluminum electrodes were evaluated by measuring the magnitude of impedance and cyclic voltammetric responses of anodized and colored electrodes. An irreversible corrosion response was observed at the cyclic voltammogram of the colored aluminum electrode. The current and threshold potential of corrosion responses strongly depends on the applied conditions during anodizing, coloring and sealing stages. In addition, significant changes in impedance at the ac voltammogram and noise level at some ac frequencies were observed, when the electrodes were colored under various conditions. In this regard, the surface of the electrode was studied by Scanning Electron Microscopy (SEM). Comparison of SEM images of the colored and uncolored aluminum specimens showed that the colored surface contained a significant numbers of pits. The results indicated that coloring aluminum with Calcon could reduce corrosion resistance of aluminum and increase roughness of the oxide film. (Abstract Copyright [2003], Wiley Periodicals, Inc.) [German] Mit Hilfe zyklischer Voltammetrie und Messungen mit Impedanzrauschmethoden wurde der Einfluss der Faerbungsbedingungen von Aluminium mit Calcon (Natrium 2,2'-Dihydroxyazonaphthalen-4-Sulfonat) auf den Korrosionswiderstand von Aluminium in 0,1 M Schwefelsaeure untersucht. Die Veraenderungen des Korrosionswiderstandes von gefaerbten Aluminiumelektroden wurden durch Messungen der Hoehe der Impedanzreaktion bzw. der Reaktion bei der zyklischen Voltammetrie von anodisierten und gefaerbten Elektroden beurteilt. Eine irreversible Korrosionsreaktion wurde beim zyklischen Voltammogramm der gefaerbten Aluminiumelektrode beobachtet. Der Strom und das

  11. Measuring the shock impedance mismatch between high-density carbon and deuterium at the National Ignition Facility

    Science.gov (United States)

    Millot, M.; Celliers, P. M.; Sterne, P. A.; Benedict, L. X.; Correa, A. A.; Hamel, S.; Ali, S. J.; Baker, K. L.; Berzak Hopkins, L. F.; Biener, J.; Collins, G. W.; Coppari, F.; Divol, L.; Fernandez-Panella, A.; Fratanduono, D. E.; Haan, S. W.; Le Pape, S.; Meezan, N. B.; Moore, A. S.; Moody, J. D.; Ralph, J. E.; Ross, J. S.; Rygg, J. R.; Thomas, C.; Turnbull, D. P.; Wild, C.; Eggert, J. H.

    2018-04-01

    Fine-grained diamond, or high-density carbon (HDC), is being used as an ablator for inertial confinement fusion (ICF) research at the National Ignition Facility (NIF). Accurate equation of state (EOS) knowledge over a wide range of phase space is critical in the design and analysis of integrated ICF experiments. Here, we report shock and release measurements of the shock impedance mismatch between HDC and liquid deuterium conducted during shock-timing experiments having a first shock in the ablator ranging between 8 and 14 Mbar. Using ultrafast Doppler imaging velocimetry to track the leading shock front, we characterize the shock velocity discontinuity upon the arrival of the shock at the HDC/liquid deuterium interface. Comparing the experimental data with tabular EOS models used to simulate integrated ICF experiments indicates the need for an improved multiphase EOS model for HDC in order to achieve a significant increase in neutron yield in indirect-driven ICF implosions with HDC ablators.

  12. Evaluation of the electrode performance for PAFC by using acid absorption, acceleration and ac-impedance measurement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang-Soo; Song, Rak-Hyun; Choi, Byung-Woo [Korea Institute of Energy Research, Taejon (Korea, Republic of)] [and others

    1996-12-31

    In PAFC, the degradation on cathode electrode caused by carbon corrosion, platinum dissolution and growth is especially severe. An acceleration test is a good technique for evaluating the degradation of electrode performance, because it does not need long time. Coleman et al used thermal cycling and on-off cycling as an acceleration test. Song et al showed that hydrogen shortage decreased the electrode performance more rapidly than that of air shortage in gas shortage test. Honji et al reported that the rate of coarsening of Pt particle is rapid in open circuit potential and this is one of major causes on the performance degradation of electrode. The cathode performance has been studied by using acid absorption, acceleration and ac-impedance measurements as functions of the polytetrafluoroethylene (PTFE) contents and sintering temperatures of the electrode.

  13. Electrical Impedance Spectroscopy for Quality Assessment of Meat and Fish: A Review on Basic Principles, Measurement Methods, and Recent Advances

    Directory of Open Access Journals (Sweden)

    Xin Zhao

    2017-01-01

    Full Text Available Electrical impedance spectroscopy (EIS, as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized products. Therefore, in order to obtain the definite quality information and ensure the quality of each product, a fast and on-line detection technology is demanded to be developed to monitor product processing. EIS has advantages of being fast, nondestructive, inexpensive, and easily implemented and shows potential to develop on-line detecting instrument to replace traditional methods to realize time, cost, skilled persons saving and further quality grading. This review outlines the fundamental theories and two common measurement methods of EIS applied to biological tissue, summarizes its application specifically for quality assessment of meat and fish, and discusses challenges and future trends of EIS technology applied for meat and fish quality assessment.

  14. Novel Zero-Heat-Flux Deep Body Temperature Measurement in Lower Extremity Vascular and Cardiac Surgery.

    Science.gov (United States)

    Mäkinen, Marja-Tellervo; Pesonen, Anne; Jousela, Irma; Päivärinta, Janne; Poikajärvi, Satu; Albäck, Anders; Salminen, Ulla-Stina; Pesonen, Eero

    2016-08-01

    The aim of this study was to compare deep body temperature obtained using a novel noninvasive continuous zero-heat-flux temperature measurement system with core temperatures obtained using conventional methods. A prospective, observational study. Operating room of a university hospital. The study comprised 15 patients undergoing vascular surgery of the lower extremities and 15 patients undergoing cardiac surgery with cardiopulmonary bypass. Zero-heat-flux thermometry on the forehead and standard core temperature measurements. Body temperature was measured using a new thermometry system (SpotOn; 3M, St. Paul, MN) on the forehead and with conventional methods in the esophagus during vascular surgery (n = 15), and in the nasopharynx and pulmonary artery during cardiac surgery (n = 15). The agreement between SpotOn and the conventional methods was assessed using the Bland-Altman random-effects approach for repeated measures. The mean difference between SpotOn and the esophageal temperature during vascular surgery was+0.08°C (95% limit of agreement -0.25 to+0.40°C). During cardiac surgery, during off CPB, the mean difference between SpotOn and the pulmonary arterial temperature was -0.05°C (95% limits of agreement -0.56 to+0.47°C). Throughout cardiac surgery (on and off CPB), the mean difference between SpotOn and the nasopharyngeal temperature was -0.12°C (95% limits of agreement -0.94 to+0.71°C). Poor agreement between the SpotOn and nasopharyngeal temperatures was detected in hypothermia below approximately 32°C. According to this preliminary study, the deep body temperature measured using the zero-heat-flux system was in good agreement with standard core temperatures during lower extremity vascular and cardiac surgery. However, agreement was questionable during hypothermia below 32°C. Copyright © 2016 Elsevier Inc. All rights reserved.

  15. Measurement of leukocyte rheology in vascular disease: clinical rationale and methodology. International Society of Clinical Hemorheology.

    Science.gov (United States)

    Wautier, J L; Schmid-Schönbein, G W; Nash, G B

    1999-01-01

    The measurement of leukocyte rheology in vascular disease is a recent development with a wide range of new opportunities. The International Society of Clinical Hemorheology has asked an expert panel to propose guidelines for the investigation of leukocyte rheology in clinical situations. This article first discusses the mechanical, adhesive and related functional properties of leukocytes (especially neutrophils) which influence their circulation, and establishes the rationale for clinically-related measurements of parameters which describe them. It is concluded that quantitation of leukocyte adhesion molecules, and of their endothelial receptors may assist understanding of leukocyte behaviour in vascular disease, along with measurements of flow resistance of leukocytes, free radical production, degranulation and gene expression. For instance, vascular cell adhesion molecule (VCAM-1) is abnormally present on endothelial cells in atherosclerosis, diabetes mellitus and inflammatory conditions. Soluble forms of intercellular adhesion molecule (ICAM-1) or VCAM can be found elevated in the blood of patients with rheumatoid arthritis or infections disease. In the second part of the article, possible technical approaches are presented and possible avenues for leukocyte rheological investigations are discussed.

  16. Measurements of pulmonary vascular permeability with PET and gallium-68 transferrin

    International Nuclear Information System (INIS)

    Mintun, M.A.; Dennis, D.R.; Welch, M.J.; Mathias, C.J.; Schuster, D.P.

    1987-01-01

    We quantified pulmonary vascular permeability with positron emission tomography (PET) and gallium-68-( 68 Ga) labeled transferrin. Six dogs with oleic acid-induced lung injury confined to the left lower lobe, two normal human volunteers, and two patients with the adult respiratory distress syndrome (ARDS) were evaluated. Lung tissue-activity measurements were obtained from sequential 1-5 min PET scans collected over 60 min, after in vivo labeling of transferrin through intravenous administration of [ 68 Ga]citrate. Blood-activity measurements were measured from simultaneously obtained peripheral blood samples. A forward rate constant describing the movement of transferrin from pulmonary vascular to extravascular compartments, the pulmonary transcapillary escape rate (PTCER), was then calculated from these data using a two-compartment model. In dogs, PTCER was 49 +/- 18 in normal lung tissue and 485 +/- 114 10(-4) min-1 in injured lung. A repeat study in these dogs 4 hr later showed no significant change. Values in the human subjects showed similarly marked differences between normal and abnormal lung tissue. We conclude that PET will be a useful method of evaluating vascular permeability changes after acute lung injury

  17. A Multi-Functional Microelectrode Array Featuring 59760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement and Neurotransmitter Detection Channels.

    Science.gov (United States)

    Dragas, Jelena; Viswam, Vijay; Shadmani, Amir; Chen, Yihui; Bounik, Raziyeh; Stettler, Alexander; Radivojevic, Milos; Geissler, Sydney; Obien, Marie; Müller, Jan; Hierlemann, Andreas

    2017-06-01

    Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48×2.43 mm 2 ) to accommodate 59,760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5 μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2,048 action-potential (AP, bandwidth: 300 Hz to 10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz to 300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.

  18. Sensitivity analysis of magnetic field measurements for magnetic resonance electrical impedance tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Scheffler, Klaus; Ehses, Philipp

    2017-01-01

    parameters, are analytically analyzed and simulated. The theoretical results are experimentally validated in a saline-filled homogenous spherical phantom with relaxation parameters similar to brain tissue. Measurement of DBz,c is also performed in a cylindrical phantom with saline and chicken meat. Results...

  19. Efficiency Analysis of Magnetic Field Measurement for MR Electrical Impedance Tomography (MREIT)

    DEFF Research Database (Denmark)

    Göksu, Cihan; Hanson, Lars G.; Ehses, Philipp

    MREIT is an emerging method to measure the ohmic tissue conductivities, with several potential biomedical applications. Its sensitivity depends on the magnitude of the applied current, which is limited to 1-2 mA in the human brain [1, 2]. This renders in-vivo applications challenging. Here, we ai...... to analyze and optimize the efficiency of two MREIT pulse sequences for in-vivo brain imaging....

  20. Non-invasive methods for measuring vascular changes in neurovascular headaches

    DEFF Research Database (Denmark)

    Schytz, Henrik W; Amin, Faisal M; Selb, Juliette

    2018-01-01

    Vascular changes during spontaneous headache attacks have been studied over the last 30 years. The interest in cerebral vessels in headache research was initially due to the hypothesis of cerebral vessels as the pain source. Here, we review the knowledge gained by measuring the cerebral vasculature...... studies of migraine and other headache disorders do not provide solid evidence for cerebral blood flow velocity changes during spontaneous attacks of migraine headache. SPECT studies have clearly shown cortical vascular changes following migraine aura and the differences between migraine with aura...... compared to migraine without aura. PET studies have shown focal activation in brain structures related to headache, but whether the changes are specific to different primary headaches have yet to be demonstrated. MR angiography has shown precise changes in large cerebral vessels during spontaneous migraine...

  1. Blood flow measurements during hemodialysis vascular access interventions - Catheter-based thermodilution or Doppler ultrasound?

    DEFF Research Database (Denmark)

    Heerwagen, Søren T; Hansen, Marc A; Schroeder, Torben V

    2012-01-01

    by ultrasound dilution was determined within three days of the procedure. The methods were compared using regression analysis and tested for systematic bias. Results: Failure to position the thermodilutional catheter correctly was observed in 8 out of 46 (17%) pre-intervention measurements. Post-intervention......Purpose: To test the clinical performance of catheter-based thermodilution and Doppler ultrasound of the feeding brachial artery for blood flow measurements during hemodialysis vascular access interventions.Methods: Thirty patients with arteriovenous fistulas who underwent 46 interventions had...

  2. Low impedance pH sensitive electrochemical devices that are potentially applicable to transcutaneous PCO2 measurements.

    Science.gov (United States)

    Yeung, H N; Beran, A V; Huxtable, R F

    1978-01-01

    Two cases of low impedance, non-glass membrane electrodes for pH measurement were evaluated: (I) Metal--metal oxide electrodes and (II) Reduction-oxidation electrodes. The fundamental cause of oxygen sensitivity of metal-metal oxide electrodes were examined and three approaches for its suppression were proposed. For the case of Sb--Sb2Ox electordes, oxygen sensitivity can be attenuated partially by cell loading, either directly across the reference electrode or indirectly across a third slave electrode. In a PO2 range of 8--54 kPa, more than 95% of the PO2 response can be suppressed by loading the cell emf to half of tis open-circuit value. The oxygen sensitivity also was observed to diminished by grinding the metal-metal oxide and pressing it under high pressure into a pellet electrode. Other metal-metal oxide electrodes that have promise in transcutaneous measurement are the Pd-PdO2 electrodes. The redox electrodes are typified by the Quinhydrone electrode. A membrane Quinhydrome electrode showed a sensitivity of 56 mV/Decade at 37 degree C and no oxygen sensitivity up to 50 kPa and a drift of 1 mV/h over a 24-h period. However, the stability deteriorated over a long-term period.

  3. Variation of poorly ventilated lung units (silent spaces) measured by electrical impedance tomography to dynamically assess recruitment.

    Science.gov (United States)

    Spadaro, Savino; Mauri, Tommaso; Böhm, Stephan H; Scaramuzzo, Gaetano; Turrini, Cecilia; Waldmann, Andreas D; Ragazzi, Riccardo; Pesenti, Antonio; Volta, Carlo Alberto

    2018-01-31

    Assessing alveolar recruitment at different positive end-expiratory pressure (PEEP) levels is a major clinical and research interest because protective ventilation implies opening the lung without inducing overdistention. The pressure-volume (P-V) curve is a validated method of assessing recruitment but reflects global characteristics, and changes at the regional level may remain undetected. The aim of the present study was to compare, in intubated patients with acute hypoxemic respiratory failure (AHRF) and acute respiratory distress syndrome (ARDS), lung recruitment measured by P-V curve analysis, with dynamic changes in poorly ventilated units of the dorsal lung (dependent silent spaces [DSSs]) assessed by electrical impedance tomography (EIT). We hypothesized that DSSs might represent a dynamic bedside measure of recruitment. We carried out a prospective interventional study of 14 patients with AHRF and ARDS admitted to the intensive care unit undergoing mechanical ventilation. Each patient underwent an incremental/decremental PEEP trial that included five consecutive phases: PEEP 5 and 10 cmH 2 O, recruitment maneuver + PEEP 15 cmH 2 O, then PEEP 10 and 5 cmH 2 O again. We measured, at the end of each phase, recruitment from previous PEEP using the P-V curve method, and changes in DSS were continuously monitored by EIT. PEEP changes induced alveolar recruitment as assessed by the P-V curve method and changes in the amount of DSS (p Recruited volume measured by the P-V curves significantly correlated with the change in DSS (r s  = 0.734, p recruitment measured using the P-V curve technique. EIT might provide useful information to titrate personalized PEEP. ClinicalTrials.gov, NCT02907840 . Registered on 20 September 2016.

  4. Assessment of plasma impedance probe for measuring electron density and collision frequency in a plasma with spatial and temporal gradients

    International Nuclear Information System (INIS)

    Hopkins, Mark A.; King, Lyon B.

    2014-01-01

    Numerical simulations and experimental measurements were combined to determine the ability of a plasma impedance probe (PIP) to measure plasma density and electron collision frequency in a plasma containing spatial gradients as well as time-varying oscillations in the plasma density. A PIP is sensitive to collision frequency through the width of the parallel resonance in the Re[Z]-vs.-frequency characteristic, while also being sensitive to electron density through the zero-crossing of the Im[Z]-vs.-frequency characteristic at parallel resonance. Simulations of the probe characteristic in a linear plasma gradient indicated that the broadening of Re[Z] due to the spatial gradient obscured the broadening due to electron collision frequency, preventing a quantitative measurement of the absolute collision frequency for gradients considered in this study. Simulation results also showed that the PIP is sensitive to relative changes in electron collision frequency in a spatial density gradient, but a second broadening effect due to time-varying oscillations made collision frequency measurements impossible. The time-varying oscillations had the effect of causing multiple zero-crossings in Im[Z] at parallel resonance. Results of experiments and simulations indicated that the lowest-frequency zero-crossing represented the lowest plasma density in the oscillations and the highest-frequency zero-crossing represented the highest plasma density in the oscillations, thus the PIP probe was found to be an effective tool to measure both the average plasma density as well as the maximum and minimum densities due to temporal oscillations

  5. An EIS alternative for impedance measurement of a high temperature PEM fuel cell stack based on current pulse injection

    DEFF Research Database (Denmark)

    Jeppesen, Christian; Araya, Samuel Simon; Sahlin, Simon Lennart

    2017-01-01

    In this paper a method for estimating the fuel cell impedance is presented, namely the current pulse injection (CPI) method, which is well suited for online implementation. This method estimates the fuel cell impedance and unlike electrochemical impedance spectroscopy (EIS), it is simple...... to implement at a low cost. This makes it appealing as a characterization method for on-line diagnostic algorithms. In this work a parameter estimation method for estimation of equivalent electrical circuit (EEC) parameters, which is suited for on-line use is proposed. Tests on a 10 cell high temperature PEM...... fuel cell show that the method yields consistent results in estimating EEC parameters for different current pulse at different current loads, with a low variance. A comparison with EIS shows that despite its simplicity the response of CPI can reproduce well the impedance response of the high...

  6. Intraesophageal impedance monitoring: clinical studies

    NARCIS (Netherlands)

    Conchillo Armendáriz, J.M.

    2007-01-01

    Electrical impedance (Z) between two electrodes is the ratio between applied voltage (U) and resulting current (I). In electrical impedance monitoring the resistance to electrical flow in an alternating current circuit is measured. Multichannel esophageal monitoring can be measured by using an

  7. Components of Variance when Assessing the Reproducibility of Body Composition Measurements using Bio-Impedance and the Hologic QDR-2000 DXA Scanner

    DEFF Research Database (Denmark)

    Jensen, Martin Bach; Hermann, Anne Pernille; Hessov, Ib

    1997-01-01

    This study evaluated the reproducibility of measuring lean tissue mass (LTM), fat mass(FM(DXA)), bone mineral content (BMC) and density (BMD) with a Hologic QDR-2000 DXA scanner, and both fat free mass (FFM(bio)) and fat mass (FM(bio)) with an impedance meter. Furthermore, the study aimed to assess...

  8. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants

    NARCIS (Netherlands)

    van der Burg, Pauline S.; Miedema, Martijn; de Jongh, Franciscus H.C.; Frerichs, Inez; van Kaam, Anton H.

    2014-01-01

    Objective: Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and

  9. Cross-sectional changes in lung volume measured by electrical impedance tomography are representative for the whole lung in ventilated preterm infants

    NARCIS (Netherlands)

    van der Burg, Pauline S.; Miedema, Martijn; de Jongh, Frans H.; Frerichs, Inez; van Kaam, Anton H.

    2014-01-01

    Electrical impedance tomography measures lung volume in a cross-sectional slice of the lung. Whether these cross-sectional volume changes are representative of the whole lung has only been investigated in adults, showing conflicting results. This study aimed to compare cross-sectional and whole lung

  10. Impedance analysis of GPCR-mediated changes in endothelial barrier function: overview and fundamental considerations for stable and reproducible measurements.

    Science.gov (United States)

    Stolwijk, Judith A; Matrougui, Khalid; Renken, Christian W; Trebak, Mohamed

    2015-10-01

    The past 20 years has seen significant growth in using impedance-based assays to understand the molecular underpinning of endothelial and epithelial barrier function in response to physiological agonists and pharmacological and toxicological compounds. Most studies on barrier function use G protein-coupled receptor (GPCR) agonists which couple to fast and transient changes in barrier properties. The power of impedance-based techniques such as electric cell-substrate impedance sensing (ECIS) resides in its ability to detect minute changes in cell layer integrity label-free and in real-time ranging from seconds to days. We provide a comprehensive overview of the biophysical principles, applications, and recent developments in impedance-based methodologies. Despite extensive application of impedance analysis in endothelial barrier research, little attention has been paid to data analysis and critical experimental variables, which are both essential for signal stability and reproducibility. We describe the rationale behind common ECIS data presentation and interpretation and illustrate practical guidelines to improve signal intensity by adapting technical parameters such as electrode layout, monitoring frequency, or parameter (resistance versus impedance magnitude). Moreover, we discuss the impact of experimental parameters, including cell source, liquid handling, and agonist preparation on signal intensity and kinetics. Our discussions are supported by experimental data obtained from human microvascular endothelial cells challenged with three GPCR agonists, thrombin, histamine, and sphingosine-1-phosphate.

  11. Photoluminescence and electrical impedance measurements on alloyed Zn{sub (1-x)}Cd{sub x}S nanocrystals

    Energy Technology Data Exchange (ETDEWEB)

    Saravanan, R. Sakthi Sudar, E-mail: rsakthiss@yahoo.com [Physics Research Centre, S.T. Hindu College, Nagercoil 629 002 (India); Mahadevan, C.K. [Physics Research Centre, S.T. Hindu College, Nagercoil 629 002 (India)

    2012-11-15

    Highlights: Black-Right-Pointing-Pointer High yield synthesis of Zn-Cd-S QDs. is achieved by solvothermal-microwave heating. Black-Right-Pointing-Pointer The samples are highly crystalline and the average particle size is {approx}3.5 nm. Black-Right-Pointing-Pointer High luminescent quantum yield and narrow emission spectral widths are obtained. Black-Right-Pointing-Pointer High conduction activation energy is observed in the case of Zn-Cd coexisting QDs. - Abstract: A series of wurtzite Zn{sub (1-x)}Cd{sub x}S (x = 0, 0.25, 0.5, 0.75 and 1) nanocrystals with average crystallite size of 1.98, 1.82, 1.80, 2.04 and 2.51 nm, respectively, have been synthesized by simple solvothermal microwave heating method. The photoluminescence yield is found to be higher in the case of alloyed nanocrystals (x = 0.25, 0.5, 0.75) as compared to ZnS (x = 0) and CdS (x = 1). The optical emission is tuned from blue (440 nm) to orange (575 nm) with the increase of Cd composition in Zn{sub (1-x)}Cd{sub x}S nanocrystal. The impedance analysis for Zn{sub (1-x)}Cd{sub x}S nanocrystals has been measured as a function of frequency and temperature. The real and imaginary part of complex impedance plots exhibit semicircle behavior in the complex plane. The AC activation energies of ZnS, Zn{sub 0.75}Cd{sub 0.25}S, Zn{sub 0.5}Cd{sub 0.5}S, Zn{sub 0.25}Cd{sub 0.75}S and CdS nanocrystals were calculated from electrical conductivity analysis and are found to be 0.188, 0.378, 0.456, 0.284 and 0.255 eV, respectively. The conductivity of the alloyed nanocrystals was higher than that of ZnS and CdS.

  12. Study on in-situ electrochemical impedance spectroscopy measurement of anodic reaction in SO_2 depolarized electrolysis process

    International Nuclear Information System (INIS)

    Xue Lulu; Zhang Ping; Chen Songzhe; Wang Laijun

    2014-01-01

    SO_2 depolarized electrolysis (SDE) is the pivotal reaction in hybrid sulfur process, one of the most promising approaches for mass hydrogen production without CO_2 emission. The net result of hybrid sulfur process is to split water into hydrogen and oxygen at a relatively low voltage, which will dramatically decrease the energy consumption for the production of hydrogen. The potential loss of SDE process could be separated into four components, i.e. reversible cell potential, anode overpotential, cathode overpotential and ohmic loss. So far, it has been identified that the total cell potential for the SO_2 depolarized electrolyzer is dominantly controlled by sulfuric acid concentration of the anolyte and electrolysis temperature of the electrolysis process. In this work, an in-situ Electrochemical Impedance Spectroscopy (EIS) measurement of the anodic SDE reaction was conducted. Results show that anodic overpotential is mainly resulted from the SO_2 oxidation reaction other than ohmic resistance or mass transfer limitation. This study extends the understanding to SDE process and gives suggestions for the further improvement of the SDE performance. (author)

  13. TSDC and impedance spectroscopy measurements on hydroxyapatite, β-tricalcium phosphate and hydroxyapatite/β-tricalcium phosphate biphasic bioceramics

    Science.gov (United States)

    Prezas, P. R.; Melo, B. M. G.; Costa, L. C.; Valente, M. A.; Lança, M. C.; Ventura, J. M. G.; Pinto, L. F. V.; Graça, M. P. F.

    2017-12-01

    Bone grafting and surgical interventions related with orthopaedic disorders consist in a big business, generating large revenues worldwide every year. There is a need to replace the biomaterials that currently still dominate this market, i.e., autografts and allografts, due to their disadvantages, such as limited availability, need for additional surgeries and diseases transmission possibilities. The most promising replacement materials are biomaterials with bioactive properties, such as the calcium phosphate-based bioceramics group. The bioactivity of these materials, i.e., the rate at which they promote the growth and directly bond with the new host biological bone, can be enhanced through their electrical polarization. In the present work, the electrical polarization features of pure hydroxyapatite (Hap), pure β-tricalcium phosphate (β-TCP) and biphasic hydroxyapatite/β-tricalcium phosphate composites (HTCP) were analyzed by measuring thermally stimulated depolarization currents (TSDC). The samples were thermoelectrically polarized at 500 °C under a DC electric field with a magnitude of 5 kV/cm. The biphasic samples were also polarized under electric fields with different magnitudes: 2, 3, 4 and 5 kV/cm. Additionally, the depolarization processes detected in the TSDC measurements were correlated with dielectric relaxation processes observed in impedance spectroscopy (IS) measurements. The results indicate that the β-TCP crystalline phase has a considerable higher ability to store electrical charge compared with the Hap phase. This indicates that it has a suitable composition and structure for ionic conduction and establishment of a large electric charge density, providing great potential for orthopaedic applications.

  14. Measurement of ac electrical conductivity of molten glass by impedance measurement using co-axial cylinder electrode

    International Nuclear Information System (INIS)

    Shah, J.G.; Yalmali, V.S.; Tawde, Manisha; Mishra, R.

    2006-01-01

    The need of nuclear power as an energy source requires the solution of many problems. One of the most important is fixation of high level radioactive waste (HLW) in suitable borosilicate glass formulation. The major issue with this process is maximum waste loading in the final vitrified product without compromising on long term product characteristics. The electrical resistivity measurement at high temperature could not be measured with good precision using standard parallel plate electrode configuration due to error in cell constant measurement. Hence a high accuracy, calibration free technique consisting of co-axial electrodes was employed

  15. Impedance of accelerator components

    International Nuclear Information System (INIS)

    Corlett, J.N.

    1996-05-01

    As demands for high luminosity and low emittance particle beams increase, an understanding of the electromagnetic interaction of these beams with their vacuum chamber environment becomes more important in order to maintain the quality of the beam. This interaction is described in terms of the wake field in time domain, and the beam impedance in frequency domain. These concepts are introduced, and related quantities such as the loss factor are presented. The broadband Q = 1 resonator impedance model is discussed. Perturbation and coaxial wire methods of measurement of real components are reviewed

  16. Bridge Network for Measuring Very Small Impedances from 4.2 to 300 degrees K with a Null-Detector Sensitivity of 10-11 Volt

    DEFF Research Database (Denmark)

    Bak, Christen Kjeldahl; Dalsgaard, Erik

    1967-01-01

    An ac measuring technique devised primarily for measuring galvanomagnetic effects in metals is presented. The instrument may, however, be useful whenever it is desired to measure and record continuously impedances in the range 10−3 to 10−8 Omega. The sample assembly is disscussed in some detail....... Measurements with the bridge show that in the temperature range 300°K to 4.2°K the noise level changes from 30×10−11 V to 10−11 V without any zero shift, and as a result the lower limit for the impedance range changes from 10−6 Omega to less than 5×10−8 Omega. ©1967 The American Institute of Physics...

  17. Using cell-substrate impedance and live cell imaging to measure real-time changes in cellular adhesion and de-adhesion induced by matrix modification.

    Science.gov (United States)

    Rees, Martin D; Thomas, Shane R

    2015-02-19

    Cell-matrix adhesion plays a key role in controlling cell morphology and signaling. Stimuli that disrupt cell-matrix adhesion (e.g., myeloperoxidase and other matrix-modifying oxidants/enzymes released during inflammation) are implicated in triggering pathological changes in cellular function, phenotype and viability in a number of diseases. Here, we describe how cell-substrate impedance and live cell imaging approaches can be readily employed to accurately quantify real-time changes in cell adhesion and de-adhesion induced by matrix modification (using endothelial cells and myeloperoxidase as a pathophysiological matrix-modifying stimulus) with high temporal resolution and in a non-invasive manner. The xCELLigence cell-substrate impedance system continuously quantifies the area of cell-matrix adhesion by measuring the electrical impedance at the cell-substrate interface in cells grown on gold microelectrode arrays. Image analysis of time-lapse differential interference contrast movies quantifies changes in the projected area of individual cells over time, representing changes in the area of cell-matrix contact. Both techniques accurately quantify rapid changes to cellular adhesion and de-adhesion processes. Cell-substrate impedance on microelectrode biosensor arrays provides a platform for robust, high-throughput measurements. Live cell imaging analyses provide additional detail regarding the nature and dynamics of the morphological changes quantified by cell-substrate impedance measurements. These complementary approaches provide valuable new insights into how myeloperoxidase-catalyzed oxidative modification of subcellular extracellular matrix components triggers rapid changes in cell adhesion, morphology and signaling in endothelial cells. These approaches are also applicable for studying cellular adhesion dynamics in response to other matrix-modifying stimuli and in related adherent cells (e.g., epithelial cells).

  18. Specificity and sensitivity of noninvasive measurement of pulmonary vascular protein leak

    International Nuclear Information System (INIS)

    Dauber, I.M.; Pluss, W.T.; VanGrondelle, A.; Trow, R.S.; Weil, J.V.

    1985-01-01

    Noninvasive techniques employing external counting of radiolabeled protein have the potential for measuring pulmonary vascular protein permeability, but their specificity and sensitivity remain unclear. The authors tested the specificity and sensitivity of a double-radioisotope method by injecting radiolabeled albumin ( 131 I) and erythrocytes (/sup 99m/Tc) into anesthetized dogs and measuring the counts of each isotope for 150 min after injection with an external gamma probe fixed over the lung. They calculated the rate of increase of albumin counts measured by the probe (which reflects the rate at which protein leaks into the extravascular space). To assess permeability the authors normalized the rate of increase in albumin counts for changes in labeled erythrocyte signal to minimize influence of changes in vascular surface area and thus derived an albumin leak index. They measured the albumin leak index and gravimetric lung water during hydrostatic edema (acutely elevating left atrial pressure by left atrial balloon inflation: mean pulmonary arterial wedge pressure = 22.6 Torr) and in lung injury edema induced by high- (1.0 g/kg) and low-dose (0.25 g/kg) intravenous thiourea. To test specificity hydrostatic and high-dose thiourea edema were compared. The albumin leak index increased nearly fourfold from control after thiourea injury (27.2 +/- 2.3 x 10-4 vs. 7.6 +/- 0.9 x 10-4 min-1) but did not change from control levels after elevating left atrial pressure (8.9 +/- 1.2 x 10-4 min-1) despite comparable increases in gravimetric lung water. To test sensitivity the authors compared low-dose thiourea with controls. Following low-dose thiourea, the albumin leak index nearly doubled despite the absence of a measurable increase in lung water

  19. Feasibility and acceptability of a self-measurement using a portable bioelectrical impedance analysis, by the patient with chronic heart failure, in acute decompensated heart failure.

    Science.gov (United States)

    Huguel, Benjamin; Vaugrenard, Thibaud; Saby, Ludivine; Benhamou, Lionel; Arméro, Sébastien; Camilleri, Élise; Langar, Aida; Alitta, Quentin; Grino, Michel; Retornaz, Frédérique

    2018-06-01

    Chronic heart failure (CHF) is a major public health matter. Mainly affecting the elderly, it is responsible for a high rate of hospitalization due to the frequency of acute heart failure (ADHF). This represents a disabling pathology for the patient and very costly for the health care system. Our study is designed to assess a connected and portable bioelectrical impedance analysis (BIA) that could reduce these hospitalizations by preventing early ADHF. This prospective study included patients hospitalized in cardiology for ADHF. Patients achieved 3 self-measurements using the BIA during their hospitalization and answered a questionnaire evaluating the acceptability of this self-measurement. The results of these measures were compared with the clinical, biological and echocardiographic criteria of patients at the same time. Twenty-three patients were included, the self-measurement during the overall duration of the hospitalization was conducted autonomously by more than 80% of the patients. The acceptability (90%) for the use of the portable BIA was excellent. Some correlations were statistically significant, such as the total water difference to the weight difference (p=0.001). There were common trends between the variation of impedance analysis measures and other evaluation criteria. The feasibility and acceptability of a self-measurement of bioelectrical impedance analysis by the patient in AHF opens up major prospects in the management of monitoring patients in CHF. The interest of this tool is the prevention of ADHF leading to hospitalization or re-hospitalizations now requires to be presented by new studies.

  20. Transcephalic electrical impedance in the study of cerebral circulation in a juvenile pig model.

    Science.gov (United States)

    Grönlund, J; Bartocci, M; Kääpä, P; Jahnukainen, T; Rautanen, M; Halkola, L; Välimäki, I

    1997-11-01

    Transcephalic electrical impedance offers a technique for non-invasive, cot-side monitoring of neonatal cerebral circulation but the exact nature of the signal is somewhat ambiguous. The impedance signal is examined in an animal project where the ventilator settings are adjusted (20 min-1-10 min-1-40 min-1 for 10 min periods each) to produce circulatory changes. Six juvenile pigs are intubated, and ECG, arterial blood pressure, carotid flow (CF) by electromagnetic flowmeter and impedance are continuously monitored and stored on analogue tape. Cardiac output by thermodilution, blood oxygen (pO2) and carbon dioxide (pCO2) tensions are measured. ECG is converted to heart rate, mean blood pressure is integrated, and the high-frequency (1.50-4.00 Hz) component of the impedance signal delta Z is computed using autoregressive spectral estimation. Stroke volume, peripheral vascular resistance (PVR) and cerebral vascular resistance (CVR) are calculated. pCO2 and CF increase and pO2 decreases during hypoventilation. CF correlates positively with cardiac output, stroke volume, delta Z and pCO2, and negatively with pO2 and CVR. delta Z correlates positively with heart rate and cardiac output, and negatively with PVR and CVR. It is concluded that the impedance signal is related to the amount of blood transmitted to the brain by every beat of the heart, depending on the changes in both the systemic circulation and the cerebral vascular compliance.

  1. Measurement of electrical impedance of a Berea sandstone core during the displacement of saturated brine by oil and CO2 injections

    Science.gov (United States)

    Liu, Yu; Xue, Ziqiu; Park, Hyuck; Kiyama, Tamotsu; Zhang, Yi; Nishizawa, Osamu; Chae, Kwang-seok

    2015-12-01

    Complex electrical impedance measurements were performed on a brine-saturated Berea sandstone core while oil and CO2 were injected at different pressures and temperatures. The saturations of brine, oil, and CO2 in the core were simultaneously estimated using an X-ray computed tomography scanner. The formation factor of this Berea core and the resistivity indexes versus the brine saturations were calculated using Archie's law. The experimental results found different flow patterns of oil under different pressures and temperatures. Fingers were observed for the first experiment at 10 MPa and 40 °C. The fingers were restrained as the viscosity ratio of oil and water changed in the second (10 MPa and 25 °C) and third (5 MPa and 25 °C) experiments. The resistivity index showed an exponential increase with a decrease in brine saturation. The saturation exponent varied from 1.4 to 4.0 at different pressure and temperature conditions. During the oil injection procedure, the electrical impedance increased with oil saturation and was significantly affected by different oil distributions; therefore, the impedance varied whether the finger was remarkable or not, even if the oil saturation remained constant. During the CO2 injection steps, the impedance showed almost no change with CO2 saturation because the brine in the pores became immobile after the oil injection.

  2. Electrical impedance spectroscopy for quality assessment of meat and fish: A review on basic principles, measurement methods, and recent advances

    Science.gov (United States)

    Electrical impedance spectroscopy (EIS), as an effective analytical technique for electrochemical system, has shown a wide application for food quality and safety assessment recently. Individual differences of livestock cause high variation in quality of raw meat and fish and their commercialized pr...

  3. Exact measurement of vascular lumina in digital subtraction arteriography (DSA) during stent implantations and percutaneous transluminal angioplasty (PTA)

    Energy Technology Data Exchange (ETDEWEB)

    Pfluger, T [Dept. of Radiology, Univ. of Munich (Germany); Kueffer, G [Dept. of Radiology, Univ. of Munich (Germany); Hahn, D [Dept. of Radiology, Univ. of Munich (Germany)

    1992-06-01

    There are inherent difficulties in using high-resolution DSA in interventional radiology for measuring vascular luminal diameter since enlargement ratios are not constant. We present a system that permits accurate determination of vascular lumen diameters by means of a special angiographic catheter with predefined marking points. The accuracy of this measuring method was explored in tests using phantoms. In vivo practicability of the method was proved in PTA and stent implantations in 39 patients. This method with a maximum error of measurement of 5% appears to provide adequate safety in the choice of suitable dilating balloons and stents in interventional vascular procedures. In follow-up, it permits the accurate measurement of neo-intimal thickness. (orig.)

  4. Characteristics of short distance field of a source radiating at electronic frequencies in a ionospheric plasma. Applications to density and electron temperature measurement by mutual impedance probe

    International Nuclear Information System (INIS)

    Debrie, R.

    1983-06-01

    Realization of a new type of radio-frequency probe, the mutual-impedance probe (or the quadrupole probe) is developed. Theoretical results obtained with a cold plasma description of the ionized medium with static magnetic field. Transfer impedance between two dipoles in an homogeneous hot and isotope plasma is then calculated. In equatorial ionosphere, measurements made by the H.F. quadrupole probe, in the Veronique rocket, during the Cisaspe experiment, have been interpreted with this hot plasma theory. The influence of a plasma drift with respect to the emitter dipole is analyzed. The influence of a static magnetic field in hot and homogeneous plasma, on the frequency response curve of the mutual impedance is studied. For, in ionospheric plasmas of auroral and polar zones, the earth magnetic field is no more negligible and gives to the plasma dielectric, strongly anisotropic, properties well described by the microscopic theory in hot magnetoplasma. The space time fast evolution of characteristics of plasma encountered in space experiments has been shown up with a new method of measurement the self-oscillating quadrupole probe. The work synthesis is put in a concrete form on the polar satellite Aureol-3 the first results of which are presented. This satellite allows a precise study of ionosphere auroral zones. At last, it is shown that methods developed for electron density and temperature measurements can be transposed in low frequency. In this case, measurements with quadrupole probe allow to get the ion average mass by lower hybrid frequency excitation [fr

  5. Estimation of Membrane Hydration Status for Standby Proton Exchange Membrane Fuel Cell Systems by Impedance Measurement: First Results on Stack Characterization

    DEFF Research Database (Denmark)

    Bidoggia, Benoit; Kær, Søren Knudsen

    Fuel cells have started replacing traditional lead-acid battery banks in backup systems. Although these systems are characterized by long periods of standby, they must be able to start at any instant in the shortest time. In the case of low temperature proton exchange membrane fuel cell systems......, a precise estimation of hydration status of the fuel cell during standby is important for a fast and safe startup. In this article, the measurement of the complex impedance of the fuel cell is suggested as a method to estimate the membrane hydration status. A 56-cell fuel cell stack has been symmetrically...... fed with air whose temperature and relative humidity were controlled, and its complex impedance was measured at different frequencies and for different values of relative humidity. After showing that the experiment was repeatable, the fuel cell stack was characterized, a power regression model...

  6. Oxygen tension in human tumours measured with polarographic needle electrodes and its relationship to vascular density, necrosis and hypoxia

    International Nuclear Information System (INIS)

    Lyng, Heidi; Sundfoer, Kolbein; Rofstad, Einar K.

    1997-01-01

    Background and purpose: The use of polarographic needle electrodes for measurement of oxygen tension (pO 2 ) in tumours requires documentation of the validity of the method. In the present work the pO 2 values measured polarographically with the Eppendorf pO 2 histograph in human tumours were compared with the histological appearance of the tumour tissue, i.e. vascular density, fraction of necrosis and fraction of hypoxic tissue, to investigate whether the measurements reflected the expected pO 2 . Materials and methods: The pO 2 was measured in cervix tumours in patients and in human melanoma xenografted tumours in athymic mice. Vascular density was determined in the cervix tumours by histological analysis of biopsies from the pO 2 measurement tracks. Fraction of necrosis and fraction of hypoxic tissue, i.e. tissue binding the hypoxia marker pimonidazole, were determined in the melanomas by analysis of histological sections from the tumour planes in which the pO 2 measurements were performed. Results: The pO 2 distributions showed large intratumour heterogeneity. In cervix tumours, tumour regions with vascular density (vascular length per unit tissue volume) in the range of 47-77 mm/mm 3 showed higher pO 2 than tumour regions with vascular density in the range of 20-47 mm/mm 3 , which in turn showed higher pO 2 than tumour regions with vascular density in the range of 0-20 mm/mm 3 . In melanomas, tumour regions in which necrosis and hypoxia constituted more than 50% of the tissue showed lower pO 2 than other tumour regions. Conclusions: The pO 2 measured in the tumours was consistent with the histological appearance of the tissue in which the measurements were performed, suggesting that reliable pO 2 distributions of tumours can be obtained with polarographic needle electrodes

  7. Measurement of vascular flow in the brain with the xenon/CT method

    International Nuclear Information System (INIS)

    Wist, A.O.; Cothran, A.; Fatouros, P.P.; Kishore, P.R.S.

    1988-01-01

    The authors are proposing a modification of the xenon/CT method that allows measurement of the flow in the different brain vessels. Based on an improved stable xenon/CT method, they developed several additional algorithms to differentiate the vessel flow from tissue flow and from artifacts and noise, which are based on the height, steepness, and other parameters of the detected flow values. The vessel flow maps, together with the tissue flow maps and new composite flow maps of recent patients, demonstrate that the stable xenon/CT technique can be extended to quantify vascular flow in the brain. The diagnostic capability of this method can be further improved by removing the vessel flow from the flow maps

  8. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Directory of Open Access Journals (Sweden)

    Johanna M Walz

    Full Text Available Vascular endothelial growth factor-A (VEGF-A is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements.Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD, cannula (butterfly vs. neonatal, type of centrifuge (swing-out vs. fixed-angle, time before and after centrifugation, filling level (completely filled vs. half-filled tubes and analyzing method (ELISA vs. multiplex bead array. Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model.The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes.VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  9. Pre-Analytical Parameters Affecting Vascular Endothelial Growth Factor Measurement in Plasma: Identifying Confounders.

    Science.gov (United States)

    Walz, Johanna M; Boehringer, Daniel; Deissler, Heidrun L; Faerber, Lothar; Goepfert, Jens C; Heiduschka, Peter; Kleeberger, Susannah M; Klettner, Alexa; Krohne, Tim U; Schneiderhan-Marra, Nicole; Ziemssen, Focke; Stahl, Andreas

    2016-01-01

    Vascular endothelial growth factor-A (VEGF-A) is intensively investigated in various medical fields. However, comparing VEGF-A measurements is difficult because sample acquisition and pre-analytic procedures differ between studies. We therefore investigated which variables act as confounders of VEGF-A measurements. Following a standardized protocol, blood was taken at three clinical sites from six healthy participants (one male and one female participant at each center) twice one week apart. The following pre-analytical parameters were varied in order to analyze their impact on VEGF-A measurements: analyzing center, anticoagulant (EDTA vs. PECT / CTAD), cannula (butterfly vs. neonatal), type of centrifuge (swing-out vs. fixed-angle), time before and after centrifugation, filling level (completely filled vs. half-filled tubes) and analyzing method (ELISA vs. multiplex bead array). Additionally, intrapersonal variations over time and sex differences were explored. Statistical analysis was performed using a linear regression model. The following parameters were identified as statistically significant independent confounders of VEGF-A measurements: analyzing center, anticoagulant, centrifuge, analyzing method and sex of the proband. The following parameters were no significant confounders in our data set: intrapersonal variation over one week, cannula, time before and after centrifugation and filling level of collection tubes. VEGF-A measurement results can be affected significantly by the identified pre-analytical parameters. We recommend the use of CTAD anticoagulant, a standardized type of centrifuge and one central laboratory using the same analyzing method for all samples.

  10. Development of High-Throughput Method for Measurement of Vascular Nitric Oxide Generation in Microplate Reader.

    Science.gov (United States)

    Abd El-Hay, Soad S; Colyer, Christa L

    2017-01-13

    Despite the importance of nitric oxide (NO) in vascular physiology and pathology, a high-throughput method for the quantification of its vascular generation is lacking. By using the fluorescent probe 4-amino-5-methylamino-2',7'-difluorofluorescein (DAF-FM), we have optimized a simple method for the determination of the generation of endothelial nitric oxide in a microplate format. A nitric oxide donor was used (3-morpholinosydnonimine hydrochloride, SIN-1). Different factors affecting the method were studied, such as the effects of dye concentration, different buffers, time of reaction, gain, and number of flashes. Beer's law was linear over a nanomolar range (1-10 nM) of SIN-1 with wavelengths of maximum excitation and emission at 495 and 525 nm; the limit of detection reached 0.897 nM. Under the optimized conditions, the generation of rat aortic endothelial NO was measured by incubating DAF-FM with serial concentrations (10-1000 µM) of acetylcholine (ACh) for 3 min. To confirm specificity, N ω -Nitro-l-arginine methyl ester (l-NAME)-the standard inhibitor of endothelial NO synthase-was found to inhibit the ACh-stimulated generation of NO. In addition, vessels pre-exposed for 1 h to 400 µM of the endothelial damaging agent methyl glyoxal showed inhibited NO generation when compared to the control stimulated by ACh. The capability of the method to measure micro-volume samples makes it convenient for the simultaneous handling of a very large number of samples. Additionally, it allows samples to be run simultaneously with their replicates to ensure identical experimental conditions, thus minimizing the effect of biological variability.

  11. Real-time measurements of endogenous CO production from vascular cells using an ultrasensitive laser sensor

    Science.gov (United States)

    Morimoto, Y.; Durante, W.; Lancaster, D. G.; Klattenhoff, J.; Tittel, F. K.

    2001-01-01

    Carbon monoxide (CO) has been implicated as a biological messenger molecule analogous to nitric oxide. A compact gas sensor based on a midinfrared laser absorption spectroscopy was developed for direct and real-time measurement of trace levels (in approximate pmol) of CO release by vascular cells. The midinfrared light is generated by difference frequency mixing of two nearinfrared lasers in a nonlinear optical crystal. A strong infrared absorption line of CO (4.61 microm) is chosen for convenient CO detection without interference from other gas species. The generation of CO from cultured vascular smooth muscle cells was detected every 20 s without any chemical modification to the CO. The sensitivity of the sensor reached 6.9 pmol CO. CO synthesis was measured from untreated control cells (0.25 nmol per 10(7) cells/h), sodium nitroprusside-treated cells (0.29 nmol per 10(7) cells/h), and hemin-treated cells (0.49 nmol per 10(7) cells/h). The sensor also detected decreases in CO production after the addition of the heme oxygenase (HO) inhibitor tin protoporphyrin-IX (from 0.49 to 0.02 nmol per 10(7) cells/h) and increases after the administration of the HO substrate hemin (from 0.27 to 0.64 nmol per 10(7) cells/h). These results demonstrate that midinfrared laser absorption spectroscopy is a useful technique for the noninvasive and real-time detection of trace levels of CO from biological tissues.

  12. Development of High-Throughput Method for Measurement of Vascular Nitric Oxide Generation in Microplate Reader

    Directory of Open Access Journals (Sweden)

    Soad S. Abd El-Hay

    2017-01-01

    Full Text Available Background: Despite the importance of nitric oxide (NO in vascular physiology and pathology, a high-throughput method for the quantification of its vascular generation is lacking. Objective: By using the fluorescent probe 4-amino-5-methylamino-2′,7′-difluorofluorescein (DAF-FM, we have optimized a simple method for the determination of the generation of endothelial nitric oxide in a microplate format. Methods: A nitric oxide donor was used (3-morpholinosydnonimine hydrochloride, SIN-1. Different factors affecting the method were studied, such as the effects of dye concentration, different buffers, time of reaction, gain, and number of flashes. Results: Beer’s law was linear over a nanomolar range (1–10 nM of SIN-1 with wavelengths of maximum excitation and emission at 495 and 525 nm; the limit of detection reached 0.897 nM. Under the optimized conditions, the generation of rat aortic endothelial NO was measured by incubating DAF-FM with serial concentrations (10–1000 µM of acetylcholine (ACh for 3 min. To confirm specificity, Nω-Nitro-l-arginine methyl ester (l-NAME—the standard inhibitor of endothelial NO synthase—was found to inhibit the ACh-stimulated generation of NO. In addition, vessels pre-exposed for 1 h to 400 µM of the endothelial damaging agent methyl glyoxal showed inhibited NO generation when compared to the control stimulated by ACh. Conclusions: The capability of the method to measure micro-volume samples makes it convenient for the simultaneous handling of a very large number of samples. Additionally, it allows samples to be run simultaneously with their replicates to ensure identical experimental conditions, thus minimizing the effect of biological variability.

  13. Development of a generalized correlation for phase-velocity measurements obtained from impedance-probe pairs in two-phase flow systems

    International Nuclear Information System (INIS)

    Hsu, C.T.; Keshock, E.G.; McGill, R.N.

    1983-01-01

    A flag type electrical impedance probe has been developed at the Oak Ridge National Lab (ORNL) to measure liquid- and vapor-phase velocities in steam-water mixtures flowing through rod bundles. Measurements are made by utilizing the probes in pairs, installed in line, parallel to the flow direction, and extending out into the flow channel. The present study addresses performance difficulties by examining from a fundamental point of view the two-phase flow system which the impedance probes typically operate in. Specifically, the governing equations (continuity, momentum, energy) were formulated for both air-water and steam-water systems, and then subjected to a scaling analysis. The scaling analysis yielded the appropriate dimensionless parameters of significance in both kinds of systems. Additionally, with the aid of experimental data obtained at ORNL, those parameters of significant magnitude were established. As a result, a generalized correlation was developed for liquid and vapor phase velocities that makes it possible to employ the impedance probe velocity measurement technique in a wide variety of test configurations and fluid combinations

  14. Localised electrochemical impedance measurements of a polymer electrolyte fuel cell using a reference electrode array to give cathode-specific measurements and examine membrane hydration dynamics

    Science.gov (United States)

    Engebretsen, Erik; Hinds, Gareth; Meyer, Quentin; Mason, Tom; Brightman, Edward; Castanheira, Luis; Shearing, Paul R.; Brett, Daniel J. L.

    2018-04-01

    Advances in bespoke diagnostic techniques for polymer electrolyte fuel cells continue to provide unique insight into the internal operation of these devices and lead to improved performance and durability. Localised measurements of current density have proven to be extremely useful in designing better fuel cells and identifying optimal operating strategies, with electrochemical impedance spectroscopy (EIS) now routinely used to deconvolute the various losses in fuel cells. Combining the two techniques provides another dimension of understanding, but until now each localised EIS has been based on 2-electrode measurements, composed of both the anode and cathode responses. This work shows that a reference electrode array can be used to give individual electrode-specific EIS responses, in this case the cathode is focused on to demonstrate the approach. In addition, membrane hydration dynamics are studied under current load steps from open circuit voltage. A three-stage process is identified associated with an initial rapid reduction in membrane resistance after 10 s of applying a current step, followed by a slower ramp to approximately steady state, which was achieved after ∼250 s. These results support previously published work that has looked at membrane swelling dynamics and reveal that membrane hydration/membrane resistance is highly heterogeneous.

  15. MR volumetric measurement of medial temporal lobe in differentiating Alzheimer disease and subcortical ischemic vascular dementia

    International Nuclear Information System (INIS)

    Wang Liang; Li Kuncheng; Liu Shuliang

    2003-01-01

    Objective: To evaluate the value of measurement of medial temporal structure by MR imaging volumetry in the differential diagnosis for patients with Alzheimer's disease (AD) and subcortical ischemic vascular dementia (SIVD). Methods: Thirty-three probable patients of AD, 33 normal controls, and 17 patients suspected with SIVD had been scanned by MRI, and volumetric measurements of amygdala (AMY), hippocampal formations (HF), entorhinal cortices (EC), parahippocampal gyri (PHG), and temporal horn of lateral ventricle (TH) were done on a serial reconstructed MR images. Results: Both atrophy of HF and dilatation of TH were significant (P<0.05) in SIVD group compared with that in control group. All the measurements with the exception of TH were atrophied significantly (P<0.001) in AD group compared with that in SIVD group and could significantly discriminate the two group. Among these indexes, the left EC provided the best discrimination with the specificity of 82.4%, sensitivity of 87.9%, and accuracy of 86.0%, respectively, and the average accuracy of bilateral EC in discrimination was 85%. Conclusion: The MR imaging volumetric measurements of medial temporal structure could offer useful information in discriminating individuals with AD from that with SIVD. Meanwhile, it should be understood that the AD-type pathological changes could also be induced by cerebrovascular disease

  16. A 0.18 μm CMOS LDO Regulator for an On-Chip Sensor Array Impedance Measurement System.

    Science.gov (United States)

    Pérez-Bailón, Jorge; Márquez, Alejandro; Calvo, Belén; Medrano, Nicolás

    2018-05-02

    This paper presents a fully integrated 0.18 μm CMOS Low-Dropout (LDO) Voltage Regulator specifically designed to meet the stringent requirements of a battery-operated impedance spectrometry multichannel CMOS micro-instrument. The proposed LDO provides a regulated 1.8 V voltage from a 3.6 V to 1.94 V battery voltage over a −40 °C to 100 °C temperature range, with a compact topology (sensors.

  17. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    Science.gov (United States)

    Santos, José; Janeiro, Fernando M.; Ramos, Pedro M.

    2015-10-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed.

  18. Development, implementation, and characterization of a standalone embedded viscosity measurement system based on the impedance spectroscopy of a vibrating wire sensor

    International Nuclear Information System (INIS)

    Santos, José; Ramos, Pedro M; Janeiro, Fernando M

    2015-01-01

    This paper presents an embedded liquid viscosity measurement system based on a vibrating wire sensor. Although multiple viscometers based on different working principles are commercially available, there is still a market demand for a dedicated measurement system capable of performing accurate, fast measurements and requiring little or no operator training for simple systems and solution monitoring. The developed embedded system is based on a vibrating wire sensor that works by measuring the impedance response of the sensor, which depends on the viscosity and density of the liquid in which the sensor is immersed. The core of the embedded system is a digital signal processor (DSP) which controls the waveform generation and acquisitions for the measurement of the impedance frequency response. The DSP also processes the acquired waveforms and estimates the liquid viscosity. The user can interact with the measurement system through a keypad and an LCD or through a computer with a USB connection for data logging and processing. The presented system is tested on a set of viscosity standards and the estimated values are compared with the standard manufacturer specified viscosity values. A stability study of the measurement system is also performed. (paper)

  19. Cellular impedance measurement as a new tool for poxvirus titration, antibody neutralization testing and evaluation of antiviral substances

    International Nuclear Information System (INIS)

    Witkowski, Peter T.; Schuenadel, Livia; Wiethaus, Julia; Bourquain, Daniel R.; Kurth, Andreas; Nitsche, Andreas

    2010-01-01

    Research highlights: → Real-time data acquisition by RT-CES requires low operative effort. → Time to result is reduced by using RT-CES instead of conventional methods. → RT-CES enables quantification of virus titers in unknown samples. → RT-CES is a useful tool for high-throughput characterization of antiviral agents. → An RT-CES-based virus neutralization test was established. -- Abstract: Impedance-based biosensing known as real-time cell electronic sensing (RT-CES) belongs to an emerging technology for analyzing the status of cells in vitro. In the present study protocols were developed for an RT-CES-based system (xCELLigence TM , Roche Applied Science, ACEA Biosciences Inc.) to supplement conventional techniques in pox virology. First, proliferation of cells susceptible to orthopoxviruses was monitored. For virus titration cells were infected with vaccinia virus and cell status, represented by the dimensionless impedance-based cell index (CI), was monitored. A virus-dose dependent decrease in electrical impedance could be shown. Calculation of calibration curves at a suitable CI covering a dynamic range of 4 log enabled the quantification of virus titers in unknown samples. Similarly, antiviral effects could be determined as shown for anti-poxviral agents ST-246 and Cidofovir. Published values for the in vitro concentration that inhibited virus replication by 50% (IC 50 ) could be confirmed while cytotoxicity in effective concentrations was excluded in long-term incubation experiments. Finally, an RT-CES-based virus neutralization test was established. Various poxvirus-specific antibodies were examined for their neutralizing activity and a calculation mode for the neutralizing antibody titer was introduced. In summary, the presented RT-CES-based methods outmatch end-point assays by observing the cell population throughout the entire experiment while workload and time to result are reduced.

  20. Measurement and analysis of cardiopulmonary vascular in Lanzhou healthy adults with multislice spiral CT

    International Nuclear Information System (INIS)

    Shi Xiaonan; Guo Shunlin

    2013-01-01

    Objective: To constitute a normal standard of cardiopulmonary vascular diameter and size of normal adult in Lanzhou, and to compared with the other's data reported in the previous bibliography by measuring diameter and area of cardiopulmonary artery lumen of the healthy adults in Lanzhou with multislice spiral CT (MSCT). Methods: Three hundred Lanzhou adults with no cardiopulmonary disease were equally assigned to 3 groups according to their age (A group: 18-39 years, B group: 40-60 years, C group: 61-80 years; 50 females and 50 males in each group). CT data were acquired at the end of deep inspiration phase and measurements were done on 3D reconstruction image with precise landmarks. All the results were statistically analyzed. Results: The diameters and areas of the main pulmonary artery left pulmonary artery right pulmonary artery ascending aorta and descending aorta differed significantly among the 3 groups (P<0.05). In groups B and C, there were significant differences in diameters and areas of pulmonary artery left pulmonary artery and right pulmonary between different genders (P<0.05). Conclusion: Imaging standard is provided for Lanzhou adult in early diagnosis of cardiopulmonary disease. The diameters and areas of main pulmonary artery left pulmonary artery and right pulmonary artery of Lanzhou healthy adults are different from that of other regions. It may be related to the geographical environment and the state of air pollution in Lanzhou. (authors)

  1. Reference Centile Curves for Body Fat Percentage, Fat-free Mass, Muscle Mass and Bone Mass Measured by Bioelectrical Impedance in Asian Indian Children and Adolescents.

    Science.gov (United States)

    Chiplonkar, Shashi; Kajale, Neha; Ekbote, Veena; Mandlik, Rubina; Parthasarathy, Lavanya; Borade, Ashwin; Patel, Pinal; Patel, Prerna; Khadilkar, Vaman; Khadilkar, Anuradha

    2017-12-15

    To create gender-specific percentile curves for percent body fat (%BF) by Bio electrical Impedance Analysis (BIA) for screening adiposity and risk of hypertension in Indian children and generate reference curves for percent fat-free mass (%FFM), muscle mass (%LM) and bone mineral content (BMC) by using bioelectrical impedance. Secondary analysis of data from previous multicenter cross-sectional studies. Private schools from five regions of India. A random sample of 3850 healthy school children (2067 boys) (5-17 yr) from private schools in five major Indian cities. Anthropometry, blood pressure (BP) and body composition were measured by bioelectrical impedance. Reference curves were generated by the LMS method. %BF, %FFM, %LM, BMC and BP. Median %BF increased by 6% from 5 to 13 years of age and declined (around 2%) up to 17 years in boys. In girls, %BF increased by 8% from 5 to 14 years and thereafter declined by 3%. Based upon the risk of hypertension, the new cut-offs of 75th and 85th percentile of %BF were proposed for detecting over fatness and excess fatness in children. Median %FFM was 90% at 5 yrs and decreased till 12 years, and then showed a slight increase to 84% at 17 yrs in boys. In girls, it was 86% at 5 yrs and decreased till 15 yrs, and plateaued at 71.8% at 17 yrs. Reference curves for percent body fat for Indian children would be useful to screen children for health risk in clinical set up.

  2. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers by ...

  3. Small Signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2014-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterized by the mechanical resonance between the mass of the diaphragm and the compliance of its suspension which vary...... from driver to driver. Therefore, a loudspeaker emulator capable of adjusting its impedance to that of a given driver is desired for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance with an electric circuit and that its resonance frequency can be changed by tuning two resistors....

  4. Precision and accuracy in CT attenuation measurement of vascular wall using region-of-interest supported by differentiation curve

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Kidouchi, Takashi; Kuwahara, Sadatoshi; Vembar, Mani; Takei, Ryoji; Yamamoto, Asako

    2012-01-01

    Objectives: To evaluate the precision and accuracy in CT attenuation measurement of vascular wall using region-of-interest (ROI) supported by differentiation curves. Study design: We used vascular models (actual attenuation value of the wall: 87 HU) with wall thicknesses of 1.5, 1.0, or 0.5 mm, filled with contrast material of 250, 348, or 436 HU. The nine vascular models were scanned with a 64-detector CT. The wall attenuation values were measured using three sizes (diameter: 0.5, 1.0, and 1.5 mm) of ROIs without differentiation curves. Sixteen measurements were repeated for each vascular model by each of two operators. Measurements supported by differentiation curves were also performed. We used analyses of variance with repeated measures for the measured attenuations for each size of the ROI. Results: Without differentiation curves, there were significant differences in the attenuation values of the wall among the three densities of contrast material, and the attenuation values tended to be overestimated more as the contrast material density increased. Operator dependencies were also found in measurements for 0.5- and 1.5-mm thickness models. With differentiation curves, measurements were not possible for 0.5- and 1.0-mm thickness models. Using differentiation curves for 1.5-mm thickness models with a ROI of 1.0- or 1.5-mm diameter, the wall attenuations were not affected by the contrast material densities and were operator independent, measuring between 75 and 103 HU. Conclusions: The use of differentiation curves can improve the precision and accuracy in wall attenuation measurement using a ROI technique, while measurements for walls of ≤1.0 mm thickness are difficult.

  5. Advances In Impedance Theory

    International Nuclear Information System (INIS)

    Stupakov, G.

    2009-01-01

    We review recent progress in the following areas of the impedance theory: calculation of impedance of tapers and small angle collimators; optical approximation and parabolic equation for the high-frequency impedance; impedance due to resistive inserts in a perfectly conducting pipe.

  6. Systemic vascular function, measured with forearm flow mediated dilatation, in acute and stable cerebrovascular disease: a case-control study

    Directory of Open Access Journals (Sweden)

    Blacker David

    2010-10-01

    Full Text Available Abstract Background Acute ischaemic stroke is associated with alteration in systemic markers of vascular function. We measured forearm vascular function (using forearm flow mediated dilatation to clarify whether recent acute ischaemic stroke/TIA is associated with impaired systemic vascular function. Methods Prospective case control study enrolling 17 patients with recent acute ischaemic stroke/TIA and 17 sex matched controls with stroke more than two years previously. Forearm vascular function was measured using flow medicated dilatation (FMD. Results Flow mediated dilatation was 6.0 ± 1.1% in acute stroke/TIA patients and 4.7 ± 1.0% among control subjects (p = 0.18. The mean paired difference in FMD between subjects with recent acute stroke and controls was 1.25% (95% CI -0.65, 3.14; p = 0.18. Endothelium independent dilatation was measured in six pairs of participants and was similar in acute stroke/TIA patients (22.6 ± 4.3% and control subjects (19.1 ± 2.6%; p = 0.43. Conclusions Despite the small size of this study, these data indicate that recent acute stroke is not necessarily associated with a clinically important reduction in FMD.

  7. Difference between ejection times measured at two different peripheral locations as a novel marker of vascular stiffness.

    Directory of Open Access Journals (Sweden)

    Yurie Obata

    Full Text Available Pulse wave velocity (PWV has been recommended as an arterial damage assessment tool and a surrogate of arterial stiffness. However, the current technology does not allow to measure PWV both continuously and in real-time. We reported previously that peripherally measured ejection time (ET overestimates ET measured centrally. This difference in ET is associated with the inherent vascular properties of the vessel. In the current study we examined ETs derived from plethysmography simultaneously at different peripheral locations and examined the influence of the underlying arterial properties on ET prolongation by changing the subject's position. We calculated the ET difference between two peripheral locations (ΔET and its corresponding PWV for the same heartbeat. The ΔET increased with a corresponding decrease in PWV. The difference between ΔET in the supine and standing (which we call ET index was higher in young subjects with low mean arterial pressure and low PWV. These results suggest that the difference in ET between two peripheral locations in the supine vs standing positions represents the underlying vascular properties. We propose ΔET in the supine position as a potential novel real-time continuous and non-invasive parameter of vascular properties, and the ET index as a potential non-invasive parameter of vascular reactivity.

  8. Differences in body composition measured using the bioelectrical impedance analysis with steel and gel electrodes – on an example of professional fencers

    Directory of Open Access Journals (Sweden)

    Olga Mizera

    2018-03-01

    Full Text Available Introduction: Regular assessment of body composition in athletes is a key element of their nutritional status and general condition monitoring. Purpose: Analysis of differences in the impedance (I and body composition measurements performed by the use of analyzers with a constant current frequency of 50 kHz with steel and gel electrodes. Material and methods: Analysis were performed in experienced fencers by the use of analyzers: Tanita BC418MA (aT with steel electrodes (eT and Akern BIA101ASE (aA with gel electrodes (eA, eL, eT. During the first stage of the study in 48 athletes I, fat mass (FM and fat free mass (FFM were measured using aA with eB in a supine position and after 3 min using aT with eT in a standing position. Then 10 fencers were randomly selected. For them measurements were performed after 10, 13 and 16 min in a supine position using eA, eL, eB and then after 3 min in a standing one using eT. Intrinsic impedance of the 3 types of gel electrodes (eA, eL, eB were measured using aA. Results: The first stage. Differences in I, FM and FFM between eT and aA were observed (women: 101.4±52.2Ω, 1.2±2.1kg, -1.2±2.1kg, men: 98.8±27.5Ω, 1.1±1.5kg, -1.1±1.5kg, respectively. The second stage. In the subsequent measurements, differences in I were observed (women: eL-eA 3.8±1.8Ω, eB-eA 26.1±8.0Ω, eT-eA 154.4±40.6Ω;, men: of -0.7±9.4Ω, 11.1±9.2Ω, 107±36.3Ω, respectively. In both subgroups along with the increase in I, FM also increased, while  FFM decreased. Intrinsic impedance of the applied gel electrodes was measured and the differences between the results were reported (eL-eA 41.1±22.0Ω, eB-eL 138.4±20.7Ω, eB-eA 179.5Ω. As the intrinsic impedance of gel electrodes increased, an increase in the whole body I was observed. Conclusion: It seems that the observed differences in the whole body impedance were not only a simple effect of changes in a body position but they might have also been related to the intrinsic

  9. A contribution to the study of high Tc superconducting coatings and multi-layer coatings electromagnetic properties: surface impedance measurement with a tunnel diode oscillator

    International Nuclear Information System (INIS)

    Omari, A.

    1993-01-01

    A surface impedance measurement system for conducting or superconducting thin films have been developed through the electromagnetic coupling of these films to a tunnel diode oscillator. The electromagnetic response of YBa 2 Cu 3 O 7-δ superconducting films and of id/La 2-x Sr x Cu O 4 multilayers, is studied, showing the 'granular' type of these materials. The intergranular coupling is of the SIS type for the films and of the SNS type for the multilayers. A resistance increase is observed when the temperature decreases in the superconducting phase. 120 p., 45 fig., 60 ref

  10. In vivo measurement of tumor estradiol and Vascular Endothelial Growth Factor in breast cancer patients

    International Nuclear Information System (INIS)

    Garvin, Stina; Dabrosin, Charlotta

    2008-01-01

    Angiogenesis, crucial for tumor progression, is a process regulated in the tissue micro-environment. Vascular endothelial growth factor (VEGF) is a potent stimulatory factor of angiogenesis and a negative prognostic indicator of breast cancer. VEGF is biologically active in the extracellular space and hitherto, there has been a lack of techniques enabling sampling of angiogenic molecules such as VEGF in situ. The majority of breast cancers are estrogen-dependent, and estrogen has been shown to regulate VEGF in normal breast tissue and experimental breast cancer. We investigated if microdialysis may be applicable in human breast cancer for sampling of extracellular VEGF in situ and to explore if there is an association with local estradiol and VEGF levels in normal and cancerous breast tissue. Microdialysis was used to sample VEGF and estradiol in tumors and adjacent normal breast tissue in postmenopausal breast cancer patients. VEGF and estradiol were also measured in plasma, and immunohistochemical staining for VEGF was performed on tumor sections. We show that in vivo levels of extracellular VEGF were significantly higher in breast cancer tumors than in normal adjacent breast tissue. There was a significant positive correlation between estradiol and extracellular VEGF in normal breast tissue. However, no correlation was detected between estradiol and VEGF in tumors or between tumor VEGF and plasma VEGF. We conclude that VEGF and estradiol correlates significantly in normal breast tissue. Microdialysis may be used to provide novel insight in breast tumor biology and the regulation of molecules in the extracellular space of human breast tumors in vivo

  11. Results from a Novel Method for Corrosion Studies of Electroplated Lithium Metal Based on Measurements with an Impedance Scanning Electrochemical Quartz Crystal Microbalance

    Directory of Open Access Journals (Sweden)

    Martin Winter

    2013-07-01

    Full Text Available A new approach to study the chemical stability of electrodeposited lithium on a copper metal substrate via measurements with a fast impedance scanning electrochemical quartz crystal microbalance is presented. The corrosion of electrochemically deposited lithium was compared in two different electrolytes, based on lithium difluoro(oxalato borate (LiDFOB and lithium hexafluorophosphate, both salts being dissolved in solvent blends of ethylene carbonate and diethyl carbonate. For a better understanding of the corrosion mechanisms, scanning electron microscopy images of electrodeposited lithium were also consulted. The results of the EQCM experiments were supported by AC impedance measurements and clearly showed two different corrosion mechanisms caused by the different salts and the formed SEIs. The observed mass decrease of the quartz sensor of the LiDFOB-based electrolyte is not smooth, but rather composed of a series of abrupt mass fluctuations in contrast to that of the lithium hexafluorophosphate-based electrolyte. After each slow decrease of mass a rather fast increase of mass is observed several times. The slow mass decrease can be attributed to a consolidation process of the SEI or to the partial dissolution of the SEI leaving finally lithium metal unprotected so that a fast film formation sets in entailing the observed fast mass increases.

  12. Improvement of the impedance measurement reliability by some new experimental and data treatment procedures applied to the behavior of copper in neutral chloride solutions containing small heterocycle molecules

    International Nuclear Information System (INIS)

    Blajiev, O.L.; Breugelmans, T.; Pintelon, R.; Hubin, A.

    2006-01-01

    The electrochemical behavior of copper in chloride solutions containing 0.001 M concentrations of small five- and six-ring member heterocyclic molecules was investigated by means of impedance spectroscopy. The investigation was performed by a new technique based on a broadband multisine excitation. This method allows for a quantification and separation of the measurement and stohastic nonlinear noises and for an estimation of the bias non-linear contribution. It as well reduces the perturbation brought to studied system by the measurement process itself. The measurement data for some experimental conditions was quantified by fitting into a equivalent circuit corresponding to a physical model both of them developed earlier. In general, the experimental results obtained show that the number of atoms in the heterocyclic ring and the molecular conformation have a significant influence on the electrochemical response of copper in the investigated environments

  13. Simulation, measurement, and mitigation of beam instability caused by the kicker impedance in the 3-GeV rapid cycling synchrotron at the Japan Proton Accelerator Research Complex

    Science.gov (United States)

    Saha, P. K.; Shobuda, Y.; Hotchi, H.; Harada, H.; Hayashi, N.; Kinsho, M.; Tamura, F.; Tani, N.; Yamamoto, M.; Watanabe, Y.; Chin, Yong Ho; Holmes, J. A.

    2018-02-01

    The transverse impedance of eight extraction pulsed kicker magnets is a strong beam instability source in the 3-GeV rapid cycling synchrotron (RCS) at the Japan Proton Accelerator Research Complex. Significant beam instability occurs even at half of the designed 1 MW beam power when the chromaticity (ξ ) is fully corrected for the entire acceleration cycle by using ac sextupole (SX) fields. However, if ξ is fully corrected only at the injection energy by using dc SX fields, the beam is stable. In order to study realistic beam instability scenarios, including the effect of space charge and to determine practical measures to accomplish 1 MW beam power, we enhance the orbit particle tracking code to incorporate all realistic time-dependent machine parameters, including the time dependence of the impedance itself. The beam stability properties beyond 0.5 MW beam power are found to be very sensitive to a number of parameters in both simulations and measurements. In order to stabilize a beam at 1 MW beam power, two practical measures based on detailed and systematic simulation studies are determined, namely, (i) proper manipulation of the betatron tunes during acceleration and (ii) reduction of the dc SX field to reduce the ξ correction even at injection. The simulation results are well reproduced by measurements, and, as a consequence, an acceleration to 1 MW beam power is successfully demonstrated. In this paper, details of the orbit simulation and the corresponding experimental results up to 1 MW of beam power are presented. To further increase the RCS beam power, beam stability issues and possible measures beyond 1 MW beam power are also considered.

  14. Dynamic Measurement of Tumor Vascular Permeability and Perfusion using a Hybrid System for Simultaneous Magnetic Resonance and Fluorescence Imaging.

    Science.gov (United States)

    Ren, Wuwei; Elmer, Andreas; Buehlmann, David; Augath, Mark-Aurel; Vats, Divya; Ripoll, Jorge; Rudin, Markus

    2016-04-01

    Assessing tumor vascular features including permeability and perfusion is essential for diagnostic and therapeutic purposes. The aim of this study was to compare fluorescence and magnetic resonance imaging (MRI)-based vascular readouts in subcutaneously implanted tumors in mice by simultaneous dynamic measurement of tracer uptake using a hybrid fluorescence molecular tomography (FMT)/MRI system. Vascular permeability was measured using a mixture of extravascular imaging agents, GdDOTA and the dye Cy5.5, and perfusion using a mixture of intravascular agents, Endorem and a fluorescent probe (Angiosense). Dynamic fluorescence reflectance imaging (dFRI) was integrated into the hybrid system for high temporal resolution. Excellent correspondence between uptake curves of Cy5.5/GdDOTA and Endorem/Angiosense has been found with correlation coefficients R > 0.98. The two modalities revealed good agreement regarding permeability coefficients and centers-of-gravity of the imaging agent distribution. The FMT/dFRI protocol presented is able to accurately map physiological processes and poses an attractive alternative to MRI for characterizing tumor neoangiogenesis.

  15. Relationship between fluctuations in glucose levels measured by continuous glucose monitoring and vascular endothelial dysfunction in type 2 diabetes mellitus

    Directory of Open Access Journals (Sweden)

    Torimoto Keiichi

    2013-01-01

    Full Text Available Abstract Background Fluctuations in blood glucose level cause endothelial dysfunction and play a critical role in onset and/or progression of atherosclerosis. We hypothesized that fluctuation in blood glucose levels correlate with vascular endothelial dysfunction and that this relationship can be assessed using common bedside medical devices. Methods Fluctuations in blood glucose levels were measured over 24 hours by continuous glucose monitoring (CGM on admission day 2 in 57 patients with type 2 diabetes mellitus. The reactive hyperemia index (RHI, an index of vascular endothelial function, was measured using peripheral arterial tonometry (EndoPAT on admission day 3. Results The natural logarithmic-scaled RHI (L_RHI correlated with SD (r=−0.504; PPP=0.001 and percentage of time ≥200 mg/dl (r=−0.292; P=0.028. In 12 patients with hypoglycemia, L_RHI also correlated with the percentage of time at hypoglycemia (r=−0.589; P=0.044. L_RHI did not correlate with HbA1c or fasting plasma glucose levels. Furthermore, L_RHI did not correlate with LDL cholesterol, HDL cholesterol, and triglyceride levels or with systolic and diastolic blood pressures. Finally, multivariate analysis identified MAGE as the only significant determinant of L_RHI. Conclusions Fluctuations in blood glucose levels play a significant role in vascular endothelial dysfunction in type 2 diabetes. Trial registration UMIN000007581

  16. Closure of digital arteries in high vascular tone states as demonstrated by measurement of systolic blood pressure in the fingers

    DEFF Research Database (Denmark)

    Krähenbühl, B; Nielsen, S L; Lassen, N A

    1977-01-01

    by direct cooling or intra-arterial noradrenaline infusion caused a marked drop in FSP in the exposed fingers, but not in the non-exposed fingers of the same hand. The fact that the non-exposed fingers retained the normal (arm systolic) pressure level is taken to indicate that palmar arch blood pressure......Finger systolic blood pressure (FSP) was measured indirectly in normal subjects and patients with primary Raynaud phenomenon by applying a thin-walled plastic cuff around the finger and a strain gauge more distally to detect volume changes. Inducing a high vascular tone in one or more fingers...... also remained normal. In the high vascular tone state, a large transmural pressure difference must apparently be established before the digital arteries are forced open. The lowered opening pressure constitutes a manifestation of the closure phenomenon of the digital arteries described in patients...

  17. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    International Nuclear Information System (INIS)

    Li, J; Rutkove, S B

    2013-01-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  18. A flexible electrode array for muscle impedance measurements in the mouse hind limb: A tool to speed research in neuromuscular disease

    Science.gov (United States)

    Li, J.; Rutkove, S. B.

    2013-04-01

    Electrical impedance myography (EIM) is a bioelectrical impedance technique focused on the assessment of neuromuscular diseases using tetrapolar surface arrays. Recently, we have shown that reproducible and sensitive EIM measurements can be made on the gastrocnemius muscle of the mouse hind limb and that these are sensitive to disease alterations. A dedicated array would help speed data acquisition and provide additional sensitivity to disease-induced alterations. A flexible electrode array was developed with electrode sizes of 1mm × 1mm by Parlex, Inc. Tetrapolar electrode sets were arranged both parallel to (longitudinal) and orthogonally to (transverse) the major muscle fiber direction of the gastrocnemius muscle. Measurements were made with a dedicated EIM system. A total of 11 healthy animals and 7 animals with spinal muscular atrophy (a form of motor neuron disease) were evaluated after the fur was completely removed with a depilatory agent from the hind limb. Standard electrophysiologic testing (compound motor action potential amplitude and motor unit number estimation) was also performed. The flexible electrode array demonstrated high repeatability in both the longitudinal and transverse directions in the healthy and diseased animals (with intraclass correlation coefficients of 0.94 and 0.89, respectively, for phase angle measured transversely). In addition, differences between healthy and diseased animals were identifiable. For example, the 50 kHz transverse phase angle was higher in the healthy as compared to the SMA animals (16.8° ± 0.5 vs. 14.3° ± 0.7, respectively) at 21 weeks of age (p = 0.01). Differences in anisotropy were also identifiable. Correlations to several standard neurophysiologic parameters also appeared promising. This novel flexible tetrapolar electrode array can be used on the mouse hind limb and provides multidirectional data that can be used to assess muscle health. This technique has the potential of finding widespread use in

  19. Electric cell-substrate impedance sensing (ECIS) based real-time measurement of titer dependent cytotoxicity induced by adenoviral vectors in an IPI-2I cell culture model.

    Science.gov (United States)

    Müller, Jakob; Thirion, Christian; Pfaffl, Michael W

    2011-01-15

    Recombinant viral vectors are widespread tools for transfer of genetic material in various modern biotechnological applications like for example RNA interference (RNAi). However, an accurate and reproducible titer assignment represents the basic step for most downstream applications regarding a precise multiplicity of infection (MOI) adjustment. As necessary scaffold for the studies described in this work we introduce a quantitative real-time PCR (qPCR) based approach for viral particle measurement. Still an implicated problem concerning physiological effects is that the appliance of viral vectors is often attended by toxic effects on the individual target. To determine the critical viral dose leading to cell death we developed an electric cell-substrate impedance sensing (ECIS) based assay. With ECIS technology the impedance change of a current flow through the cell culture medium in an array plate is measured in a non-invasive manner, visualizing effects like cell attachment, cell-cell contacts or proliferation. Here we describe the potential of this online measurement technique in an in vitro model using the porcine ileal epithelial cell line IPI-2I in combination with an adenoviral transfection vector (Ad5-derivate). This approach shows a clear dose-depending toxic effect, as the amount of applied virus highly correlates (p<0.001) with the level of cell death. Thus this assay offers the possibility to discriminate the minimal non-toxic dose of the individual transfection method. In addition this work suggests that the ECIS-device bears the feasibility to transfer this assay to multiple other cytotoxicological questions. Copyright © 2010 Elsevier B.V. All rights reserved.

  20. Smoking, Smoking Cessation, and Measures of Subclinical Atherosclerosis in Multiple Vascular Beds in Japanese Men

    OpenAIRE

    Hisamatsu, Takashi; Miura, Katsuyuki; Arima, Hisatomi; Kadota, Aya; Kadowaki, Sayaka; Torii, Sayuki; Suzuki, Sentaro; Miyagawa, Naoko; Sato, Atsushi; Yamazoe, Masahiro; Fujiyoshi, Akira; Ohkubo, Takayoshi; Yamamoto, Takashi; Murata, Kiyoshi; Abbott, Robert D.

    2016-01-01

    Background Smoking is an overwhelming, but preventable, risk factor for cardiovascular diseases (CVD), although smoking prevalence remains high in developed and developing countries in East Asia. Methods and Results In a population?based sample of 1019 Japanese men aged 40 to 79?years, without CVD, we examined cross?sectional associations of smoking status, cumulative pack?years, daily consumption, and time since cessation, with subclinical atherosclerosis at 4 anatomically distinct vascular ...

  1. The Quantitative Measurements of Vascular Density and Flow Areas of Macula Using Optical Coherence Tomography Angiography in Normal Volunteers.

    Science.gov (United States)

    Ghassemi, Fariba; Fadakar, Kaveh; Bazvand, Fatemeh; Mirshahi, Reza; Mohebbi, Masoumeh; Sabour, Siamak

    2017-06-01

    The quantification of the density of macular vascular networks and blood flow areas in the foveal and parafoveal area in healthy subjects using optical coherence tomography angiography (OCTA). Cross-sectional, prospective study in an institutional setting at the Retina Services of Farabi Eye Hospital. One hundred twelve normal volunteers with no known ocular or systemic disease were included, including patient numbers (one or both eyes), selection procedures, inclusion/exclusion criteria, randomization procedure, and masking. En face angiogram OCTA was performed on a 3 mm × 3 mm region centered on the macula. Automated thresholding and measuring algorithm method for foveal and parafoveal blood flow and vascular density (VD) were used. The density of macular vascular networks and blood flow area in the foveal and parafoveal area were measured. A total of 224 healthy eyes from 112 subjects with a mean age of 36.4 years ± 11.3 years were included. In the foveal region, the VD of the superficial capillary network (sCN) was significantly higher than that of the deep capillary network (dCN) (31.1% ± 5.5% vs. 28.3% ± 7.2%; P < .001), whereas in the parafoveal area, VD was higher in the dCN (62.24% ± 2.8% vs. 56.5% ± 2.5%; P < .001). Flow area in the 1-mm radius circle in the sCN was less than in the dCN. Superficial foveal avascular zone (sFAZ) size was negatively correlated with the VD of the foveal sCN, but in the deep FAZ (dFAZ) was not correlated with VD or blood flow area of the fovea. There was no difference between measured VD and blood flow surface area in both eyes of the subjects. OCTA could be used as a noninvasive, repeatable, layer-free method in quantitative evaluation of VD and blood flow of macular area. The normal quantities of the vascular plexus density and flow will help in better understanding the pathophysiological basis of the vascular disease of retina. [Ophthalmic Surg Lasers Imaging Retina. 2017;48:478-486.]. Copyright 2017, SLACK

  2. NOTE: Impedance magnetocardiogram

    Science.gov (United States)

    Kandori, Akihiko; Miyashita, Tsuyoshi; Suzuki, Daisuke; Yokosawa, Koichi; Tsukada, Keiji

    2001-02-01

    We have developed an impedance magnetocardiogram (IMCG) system to detect the change of magnetic field corresponding to changes in blood volume in the heart. A low magnetic field from the electrical activity of the human heart - the so-called magnetocardiogram (MCG) - can be simultaneously detected by using this system. Because the mechanical and electrical functions in the heart can be monitored by non-invasive and non-contact measurements, it is easy to observe the cardiovascular functions from an accurate sensor position. This system uses a technique to demodulate induced current in a subject. A flux-locked circuit of a superconducting quantum interference device has a wide frequency range (above 1 MHz) because a constant current (40 kHz) is fed through the subject. It is shown for the first time that the system could measure IMCG signals at the same time as MCG signals.

  3. Oxygen surface exchange kinetics measurement by simultaneous optical transmission relaxation and impedance spectroscopy: Sr(Ti,Fe)O3-x thin film case study.

    Science.gov (United States)

    Perry, Nicola H; Kim, Jae Jin; Tuller, Harry L

    2018-01-01

    We compare approaches to measure oxygen surface exchange kinetics, by simultaneous optical transmission relaxation (OTR) and AC-impedance spectroscopy (AC-IS), on the same mixed conducting SrTi 0.65 Fe 0.35 O 3-x film. Surface exchange coefficients were evaluated as a function of oxygen activity in the film, controlled by gas partial pressure and/or DC bias applied across the ionically conducting yttria-stabilized zirconia substrate. Changes in measured light transmission through the film over time (relaxations) resulted from optical absorption changes in the film corresponding to changes in its oxygen and oxidized Fe (~Fe 4+ ) concentrations; such relaxation profiles were successfully described by the equation for surface exchange-limited kinetics appropriate for the film geometry. The k chem values obtained by OTR were significantly lower than the AC-IS derived k chem values and k q values multiplied by the thermodynamic factor (bulk or thin film), suggesting a possible enhancement in k by the metal current collectors (Pt, Au). Long-term degradation in k chem and k q values obtained by AC-IS was also attributed to deterioration of the porous Pt current collector, while no significant degradation was observed in the optically derived k chem values. The results suggest that, while the current collector might influence measurements by AC-IS, the OTR method offers a continuous, in situ , and contact-free method to measure oxygen exchange kinetics at the native surfaces of thin films.

  4. Oxygen surface exchange kinetics measurement by simultaneous optical transmission relaxation and impedance spectroscopy: Sr(Ti,Fe)O3-x thin film case study

    Science.gov (United States)

    Perry, Nicola H.; Kim, Jae Jin; Tuller, Harry L.

    2018-01-01

    Abstract We compare approaches to measure oxygen surface exchange kinetics, by simultaneous optical transmission relaxation (OTR) and AC-impedance spectroscopy (AC-IS), on the same mixed conducting SrTi0.65Fe0.35O3-x film. Surface exchange coefficients were evaluated as a function of oxygen activity in the film, controlled by gas partial pressure and/or DC bias applied across the ionically conducting yttria-stabilized zirconia substrate. Changes in measured light transmission through the film over time (relaxations) resulted from optical absorption changes in the film corresponding to changes in its oxygen and oxidized Fe (~Fe4+) concentrations; such relaxation profiles were successfully described by the equation for surface exchange-limited kinetics appropriate for the film geometry. The kchem values obtained by OTR were significantly lower than the AC-IS derived kchem values and kq values multiplied by the thermodynamic factor (bulk or thin film), suggesting a possible enhancement in k by the metal current collectors (Pt, Au). Long-term degradation in kchem and kq values obtained by AC-IS was also attributed to deterioration of the porous Pt current collector, while no significant degradation was observed in the optically derived kchem values. The results suggest that, while the current collector might influence measurements by AC-IS, the OTR method offers a continuous, in situ, and contact-free method to measure oxygen exchange kinetics at the native surfaces of thin films. PMID:29511391

  5. Time-resolved ion flux and impedance measurements for process characterization in reactive high-power impulse magnetron sputtering

    Czech Academy of Sciences Publication Activity Database

    Lundin, D.; Čada, Martin; Hubička, Zdeněk

    2016-01-01

    Roč. 34, č. 4 (2016), 1-10, č. článku 041305. ISSN 0734-2101 R&D Projects: GA ČR(CZ) GA15-00863S EU Projects: European Commission(XE) 608800 - HIPPOCAMP Institutional support: RVO:68378271 Keywords : radiofrequency current * voltage measurements * energy-distributions * sheath voltages * deposition * density * hysteresis * discharges * films * technology Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.374, year: 2016

  6. Wavelet analysis of the impedance cardiogram waveforms

    Science.gov (United States)

    Podtaev, S.; Stepanov, R.; Dumler, A.; Chugainov, S.; Tziberkin, K.

    2012-12-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt)max) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  7. Wavelet analysis of the impedance cardiogram waveforms

    International Nuclear Information System (INIS)

    Podtaev, S; Stepanov, R; Dumler, A; Chugainov, S; Tziberkin, K

    2012-01-01

    Impedance cardiography has been used for diagnosing atrial and ventricular dysfunctions, valve disorders, aortic stenosis, and vascular diseases. Almost all the applications of impedance cardiography require determination of some of the characteristic points of the ICG waveform. The ICG waveform has a set of characteristic points known as A, B, E ((dZ/dt) max ) X, Y, O and Z. These points are related to distinct physiological events in the cardiac cycle. Objective of this work is an approbation of a new method of processing and interpretation of the impedance cardiogram waveforms using wavelet analysis. A method of computer thoracic tetrapolar polyrheocardiography is used for hemodynamic registrations. Use of original wavelet differentiation algorithm allows combining filtration and calculation of the derivatives of rheocardiogram. The proposed approach can be used in clinical practice for early diagnostics of cardiovascular system remodelling in the course of different pathologies.

  8. 14CO2 labeling. A reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crop plants

    International Nuclear Information System (INIS)

    Bhupinder Singh; Sumedha Ahuja; Renu Pandey; Singhal, R.K.

    2014-01-01

    Root release of organic compounds and rate of the vascular sap flow are important for understanding the nutrient and the source-sink dynamics in plants, however, their determination is procedurally cumbersome and time consuming. We report here a simple method involving 14 C labeling for rapid and reliable measurement of root exudates and vascular sap flow rate in a variable groundnut population developed through seed gamma irradiation using a cobalt source ( 60 Co). An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  9. Test-retest reliability of pulse amplitude tonometry measures of vascular endothelial function: implications for clinical trial design.

    Science.gov (United States)

    McCrea, Cindy E; Skulas-Ray, Ann C; Chow, Mosuk; West, Sheila G

    2012-02-01

    Endothelial dysfunction is an important outcome for assessing vascular health in intervention studies. However, reliability of the standard non-invasive method (flow-mediated dilation) is a significant challenge for clinical applications and multicenter trials. We evaluated the repeatability of pulse amplitude tonometry (PAT) to measure change in pulse wave amplitude during reactive hyperemia (Itamar Medical Ltd, Caesarea, Israel). Twenty healthy adults completed two PAT tests (mean interval = 19.5 days) under standardized conditions. PAT-derived measures of endothelial function (reactive hyperemia index, RHI) and arterial stiffness (augmentation index, AI) showed strong repeatability (intra-class correlations = 0.74 and 0.83, respectively). To guide future research, we also analyzed sample size requirements for a range of effect sizes. A crossover design powered at 0.90 requires 28 participants to detect a 15% change in RHI. Our study is the first to show that PAT measurements are repeatable in adults over an interval greater than 1 week.

  10. Electrochemical Impedance Spectroscopy in Solid State Ionics: Recent Advances

    NARCIS (Netherlands)

    Boukamp, Bernard A.

    2004-01-01

    Electrochemical Impedance Spectroscopy (EIS) has become an important research tool in Solid State Ionics. Some new developments are highlighted: new methods of automatic parameter extraction from impedance measurements are briefly discussed. The Kramers–Kronig data validation test presents another

  11. Correlation between three-dimensional power Doppler and morphometric measurement of endometrial vascularity at the time of embryo implantation in women with unexplained recurrent miscarriage.

    Science.gov (United States)

    Chen, Xiaoyan; Saravelos, Sotirios H; Liu, Yingyu; Huang, Jin; Wang, Chi Chiu; Li, Tin Chiu

    2017-06-01

    Power Doppler in combination with three-dimensional (3D-PD) ultrasonography has been used as a noninvasive tool to evaluate the vascularity. However, it is unclear whether 3D-PD can accurately reflect endometrial vascularization and replace the invasive endometrial biopsy. This study aims to investigate the correlation between 3D-PD and micro vessel morphometric measurement of endometrial vascularity. Twenty-five women with unexplained recurrent miscarriage were recruited for 3D-PD and endometrial biopsy on precisely day LH + 7. Immunohistochemistry using vWF was employed to identify micro vessels in endometrial biopsy specimens followed by the use of morphometric technique to measure the mean vessel diameter and volume fractions. The vascularization index (VI), flow index (FI) and vascularization flow index (VFI) assessed by 3D-PD were calculated for both the endometrial and sub-endometrial regions. There were no significant correlations between any of the ultrasonographic measurements (endometrial thickness, endometrial volume, endometrial VI/FI/VFI, sub-endometrial volume, sub-endometrial VI/FI/VFI) and morphometric features (number of micro vessel, mean diameter of micro vessel and volume fraction measurement of vessel). This study indicates that endometrial vascularity assessed by 3D-PD could not be used to reflect changes in micro vessels of the endometrium at the time of embryo implantation in women with unexplained recurrent miscarriage.

  12. The in-line measurement of plant cell biomass using radio frequency impedance spectroscopy as a component of process analytical technology.

    Science.gov (United States)

    Holland, Tanja; Blessing, Daniel; Hellwig, Stephan; Sack, Markus

    2013-10-01

    Radio frequency impedance spectroscopy (RFIS) is a robust method for the determination of cell biomass during fermentation. RFIS allows non-invasive in-line monitoring of the passive electrical properties of cells in suspension and can distinguish between living and dead cells based on their distinct behavior in an applied radio frequency field. We used continuous in situ RFIS to monitor batch-cultivated plant suspension cell cultures in stirred-tank bioreactors and compared the in-line data to conventional off-line measurements. RFIS-based analysis was more rapid and more accurate than conventional biomass determination, and was sensitive to changes in cell viability. The higher resolution of the in-line measurement revealed subtle changes in cell growth which were not accessible using conventional methods. Thus, RFIS is well suited for correlating such changes with intracellular states and product accumulation, providing unique opportunities for employing systems biotechnology and process analytical technology approaches to increase product yield and quality. Copyright © 2013 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  13. Impedance of a nanoantenna

    International Nuclear Information System (INIS)

    Greffet, Jean-Jacques; Laroche, Marine; Marquier, Francois

    2009-01-01

    We introduce a generalized definition of the impedance of a nanoantenna that can be applied to any system. We also introduce a definition of the impedance of a two level system. Using this framework, we establish a link between the electrical engineering and the quantum optics picture of light emission.

  14. Measurement of pulmonary vascular resistance of Fontan candidates with pulmonary arterial distortion by means of pulmonary perfusion imaging

    International Nuclear Information System (INIS)

    Park, In-Sam; Mizukami, Ayumi; Tomimatsu, Hirofumi; Kondou, Chisato; Nakanishi, Toshio; Nakazawa, Makoto; Momma, Kazuo

    1998-01-01

    We measured the distribution of blood flow to the right (R) and left lung (L) by means of pulmonary perfusion imaging and calculated pulmonary vascular resistance (Rp) in 13 patients, whose right and left pulmonary artery pressures were different by 2 to 9 mmHg due to pulmonary arterial distortion (5 interruption, 8 stenosis). The right lung/left lung blood flow ratio was determined and from the ratio and the total pulmonary blood flow, which was determined using the Fick's principle, the absolute values of right and left pulmonary blood flow were calculated. Using the right and left pulmonary blood flow and the right and left pulmonary arterial pressures, right and left pulmonary vascular resistance were calculated, separately. Vascular resistance of the whole lung (Rp) was then calculated using the following equation. 1/(Rp of total lung)=1/(Rp of right lung)+1/(Rp of left lung). Rp calculated from this equation was 1.8+/-0.8 U·m 2 and all values were less than 3 U·m 2 (range 0.3-2.8). Rp estimated from the conventional method using the total pulmonary blood flow and pulmonary arterial pressures, without using the right/left blood flow ratio, ranging from 0.4 to 3.8 U·m 2 and 5 of 13 patients showed Rp>3 U·m 2 . All patients underwent Fontan operation successfully. These data indicated that this method is useful to estimate Rp and to determine the indication of Fontan operation in patients with pulmonary arterial distortions. (author)

  15. Validity of impedance-based predictions of total body water as measured by 2H dilution in African HIV/AIDS outpatients

    International Nuclear Information System (INIS)

    Diouf, Adama; Idohou Dossou, Nicole; Wade, Salimata; Gartner, Agnes; Sanon, Dominique Alexis; Bluck, Les; Wright, Antony

    2009-01-01

    Measurements of body composition are crucial in identifying HIV-infected patients at risk of malnutrition. No information is available on the validity of indirect body composition methods in African HIV-infected outpatients. Our aim was to test the validity of fifteen published equations, developed in whites, African-Americans and/or Africans who were or not HIV-infected, for predicting total body water (TBW) from bioelectrical impedance analysis (BIA) in HIV-infected patients. The second aim was to develop specific predictive equations. Thirty-four HIV-infected patients without antiretroviral treatment and oedema at the beginning of the study (age 39 (SD 7) years, BMI 18.7 (SD 3.7) kg/m2, TBW 30.4 (SD 7.2 kg) were measured at inclusion then 3 and 6 months later. In the resulting eighty-eight measurements, we compared TBW values predicted from BIA to those measured by 2H dilution. Range of bias values was 0.1-4.3, and errors showed acceptable values (2.2-3.4 kg) for fourteen equations and a high value (10.4) for one equation. Two equations developed in non-HIV-infected subjects showed non-significant bias and could be used in African HIV-infected patients. In the other cases, poor agreement indicated a lack of validity. Specific equations developed from our sample showed a higher precision of TBW prediction when using resistance at 1000kHz (1.7kg) than at 50kHz (2.3kg), this latter precision being similar to that of the valid published equations (2.3 and 2.8kg). The valid published or developed predictive equations should be cross-validated in large independent samples of African HIV-infected patients. (Authors)

  16. Body composition of adult cystic fibrosis patients and control subjects as determined by densitometry, bioelectrical impedance, total-body electrical conductivity, skinfold measurements, and deuterium oxide dilution

    International Nuclear Information System (INIS)

    Newby, M.J.; Keim, N.L.; Brown, D.L.

    1990-01-01

    This study contrasts body compositions (by six methods) of eight cystic fibrosis (CF) subjects with those of eight control subjects matched for age, height, and sex. CF subjects weighed 84% as much as control subjects. Densitometry and two bioelectrical impedance-analysis methods suggested that reduced CF weights were due to less lean tissue (10.7, 9.5, and 10.4 kg). Total-body electrical conductivity (TOBEC) and skinfold-thickness measurements indicated that CF subjects were leaner than control subjects and had less fat (5.4 and 3.6 kg) and less lean (5.2 and 7 kg) tissue. D2O dilution showed a pattern similar to TOBEC (8.3 kg less lean, 2.7 kg less fat tissue). Densitometry estimates of fat (mass and percent) were not correlated (r less than 0.74, p greater than 0.05) with any other method for CF subjects but were correlated with all other methods for control subjects. CF subjects contained less fat and lean tissue than did control subjects. Densitometry by underwater weighing is unsuitable for assessing body composition of CF patients

  17. Impedance and Collective Effects

    CERN Document Server

    Metral, E; Rumolo, R; Herr, W

    2013-01-01

    This document is part of Subvolume C 'Accelerators and Colliders' of Volume 21 'Elementary Particles' of Landolt-Börnstein - Group I 'Elementary Particles, Nuclei and Atoms'. It contains the Chapter '4 Impedance and Collective Effects' with the content: 4 Impedance and Collective Effects Introduction 4.1 Space Charge 4.2 Wake Fields and Impedances 4.3 Coherent Instabilities 4.4 Landau Damping 4.5 Two-Stream Effects (Electron Cloud and Ions) 4.6 Beam-Beam Effects 4.7 Numerical Modelling

  18. Wearable impedance monitoring system for dialysis patients.

    Science.gov (United States)

    Bonnet, S; Bourgerette, A; Gharbi, S; Rubeck, C; Arkouche, W; Massot, B; McAdams, E; Montalibet, A; Jallon, P

    2016-08-01

    This paper describes the development and the validation of a prototype wearable miniaturized impedance monitoring system for remote monitoring in home-based dialysis patients. This device is intended to assess the hydration status of dialysis patients using calf impedance measurements. The system is based on the low-power AD8302 component. The impedance calibration procedure is described together with the Cole parameter estimation and the hydric volume estimation. Results are given on a test cell to validate the design and on preliminary calf measurements showing Cole parameter variations during hemodialysis.

  19. RHIC ABORT KICKER WITH REDUCED COUPLING IMPEDANCE

    International Nuclear Information System (INIS)

    HAHN, H.; DAVINO, D.

    2002-01-01

    Kicker magnets typically represent the most important contributors to the transverse impedance budget of accelerators and storage rings. Methods of reducing the impedance value of the SNS extraction kicker presently under construction and, in view of a future performance upgrade, that of the RHIC abort kicker have been thoroughly studied at this laboratory. In this paper, the investigation of a potential improvement from using ferrite different from the BNL standard CMD5005 is reported. Permeability measurements of several ferrite types have been performed. Measurements on two kicker magnets using CMD5005 and C2050 suggest that the impedance of a magnet without external resistive damping, such as the RHIC abort kicker, would benefit

  20. Sound Propagation An impedance Based Approach

    CERN Document Server

    Kim, Yang-Hann

    2010-01-01

    In Sound Propagation: An Impedance Based Approach , Professor Yang-Hann Kim introduces acoustics and sound fields by using the concept of impedance. Kim starts with vibrations and waves, demonstrating how vibration can be envisaged as a kind of wave, mathematically and physically. One-dimensional waves are used to convey the fundamental concepts. Readers can then understand wave propagation in terms of characteristic and driving point impedance. The essential measures for acoustic waves, such as dB scale, octave scale, acoustic pressure, energy, and intensity, are explained. These measures are

  1. Variability of vascular CT measurement techniques used in the assessment abdominal aortic aneurysms

    International Nuclear Information System (INIS)

    England, Andrew; Niker, Amanda; Redmond, Claire

    2010-01-01

    Purpose: The aim of this project is to assess the variability of six CT measurement techniques for sizing abdominal aortic aneurysms (AAAs). Method: 37 CT scans with known AAAs were loaded on to a departmental picture archiving and communication system (PACS). A team of three observers, with experience in aortic CT measurements and the PACS performed a series of 2D and 3D measurements on the abdominal aorta. Each observer was asked to measure 3 quantities; anterior-posterior AAA diameter, maximum oblique AAA diameter, maximum aneurysm area using both 2D and 3D techniques. In order to test intra-observer variability each observer was asked to repeat their measurements. All measurements were taken using electronic callipers, under standardised viewing conditions using previously calibrated equipment. 3D measurements were conducted using a computer generated central luminal line (CLL). All measurements for this group were taken perpendicular to the CLL. Results: A total of 972 independent measurements were recorded by three observers. Mean intra-observer variability was lower for 2D diameter measurements (AP 1.3 ± 1.6 mm; 2D Oblique 1.2 ± 1.3 mm) and 2D areas (0.7 ± 1.3 cm 2 ) when compared to inter-observer variability (AP 1.7 ± 1.9 mm; Oblique 1.6 ± 1.7 mm; area 1.1 ± 1.5 cm 2 ). When comparing 2D with 3D measurements, differences were comparable except for 3D AP diameter and area which had lower inter-observer variability than their 2D counterparts (AP 2D 1.7 ± 1.9 mm, 3D 1.3 ± 1.3 mm; area 2D 1.1 ± 1.5 cm 2 , 3D 0.7 ± 0.7 cm 2 ). 3D area measurement was the only technique which had equal variability for intra- and inter-observer measurements. Overall observer variability for the study was good with 94-100% of all paired measurements within 5.00 mm/cm 2 or less. Using Pitman's test it can be confirmed that area measurements in the 3D plane have the least variability (r = 0.031) and 3D oblique measurements have the highest variability (r = 0

  2. Measuring body composition using the bioelectrical impedance method can predict the outcomes of gemcitabine-based chemotherapy in patients with pancreatobiliary tract cancer.

    Science.gov (United States)

    Muramatsu, Mami; Tsuchiya, Aya; Ohta, Seiko; Iijima, Yukie; Maruyama, Miyuki; Onodera, Yoshiko; Hagihara, Megumi; Nakaya, Naoki; Sato, Itaru; Omura, Kenji; Ueno, Soichiro; Nakajima, Hideo

    2015-12-01

    In order to examine the effect on body composition of anticancer drug treatments, the body composition rate in patients being treated with gemcitabine (GEM)-based chemotherapy was measured over time on an outpatient basis with a simple body composition monitor using the bioelectrical impedance (BI) method. The results revealed a significant reduction in the body fat rate (P=0.01) over the course of treatment in patients with pancreatobiliary tract cancer who became unable to continue GEM-based chemotherapy due to progressive disease or a decreased performance status. Meanwhile, no changes were observed in the body composition of control patients with urothelial carcinoma receiving GEM-based chemotherapy. In association with the adverse reactions to GEM and the hematotoxicity profile, a decreased white blood cell count was more likely to occur in body fat-dominant patients (mean fat rate, 25.8%; mean muscle rate, 26.2%), whereas a decreased blood platelet count was more likely to occur in skeletal muscle-dominant patients (mean fat rate, 23.3%; mean muscle rates, 28.7%). The correlation between body composition parameters and the relative dose intensity (RDI) associated with GEM administration was also analyzed. The results revealed a positive correlation between the RDI and basal metabolism amount (P=0.03); however, the RDI did not correlate with the body fat rate, skeletal muscle rate or body mass index (P=0.61, P=0.14 and P=0.20, respectively). In conclusion, the body composition rate measurement using the BI method over time may be useful for predicting the outcome of GEM-based chemotherapy and adverse events in patients with pancreatobiliary tract cancer. In particular, the present findings indicate that the changes in body fat rate may be helpful as an adjunct index for assessing potential continuation of chemotherapy and changes in physical conditions.

  3. Validity of impedance-based equations for the prediction of total body water as measured by deuterium dilution in African women

    International Nuclear Information System (INIS)

    Dioum, Aissatou S.; Cisse, Aita; Wade, Salimata; Gartner, Agnes; Delpeuch, Francis; Maire, Bernard; Schutz, Yves

    2005-01-01

    Background: Little information is available on the validity of simple and indirect body-composition methods in non-Western populations. Equations for predicting body composition are population- specific, and body composition differs between blacks and whites. Objective:Wetestedthehypothesisthatthevalidityofequationsfor predicting total body water (TBW) from bioelectrical impedance analysis measurements is likely to depend on the racial background of the group from which the equations were derived. Design: The hypothesis was tested by comparing, in 36 African women, TBW values measured by deuterium dilution with those predicted by 23 equations developed in white, African American, or African subjects. These cross-validations in our African sample were also compared, whenever possible, with results from other studies in black subjects. Results: Errors in predicting TBW showed acceptable values (1.3- 1.9 kg) in all cases, whereas a large range of bias (0.2-6.1 kg) was observed independently of the ethnic origin of the sample from which the equations were derived. Three equations (2 from whites and 1 from blacks) showed nonsignificant bias and could be used in Africans. In all other cases, we observed either an overestimation or under estimation of TBW with variable bias values, regardless of racial background, yielding no clear trend for validity as a function of ethnic origin. Conclusions: The findings of this cross-validation study emphasize the need for further fundamental research to explore the causes of the poor validity of TBW prediction equations across populations rather than the need to develop new prediction equations for use in Africa. (Authors)

  4. Lung disease severity in idiopathic pulmonary fibrosis is more strongly associated with impedance measures of bolus reflux than pH parameters of acid reflux alone.

    Science.gov (United States)

    Gavini, S; Borges, L F; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W

    2017-05-01

    Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF). Pathogenesis may be related to chronic micro-aspiration. We aimed to assess objective measures of GER on multichannel intraluminal impedance and pH study (MII-pH) and their relationship with pulmonary function testing (PFT) results, and to compare the performance of pH/acid reflux parameters vs corresponding MII/bolus parameters in predicting pulmonary dysfunction in IPF. This was a retrospective cohort study of IPF patients undergoing prelung transplant evaluation with MII-pH off acid suppression, and having received PFT within 3 months. Patients with prior fundoplication were excluded. Severe pulmonary dysfunction was defined using diffusion capacity of the lung for carbon monoxide (DLCO) ≤40%. Six pH/acid reflux parameters with corresponding MII/bolus reflux measures were specified a priori. Multivariate analyses were applied using forward stepwise logistic regression. Predictive value of each parameter for severe pulmonary dysfunction was calculated by area-under-the-receiver-operating-characteristic-curve or c-statistic. Forty-five subjects (67% M, age 59, 15 mild-moderate vs 30 severe) met criteria for inclusion. Patient demographics and clinical characteristics were similar between pulmonary dysfunction groups. Abnormal total reflux episodes and prolonged bolus clearance time were significantly associated with pulmonary dysfunction severity on univariate and multivariate analyses. No pH parameters were significant. The c-statistic of each pH parameter was lower than its MII counterpart in predicting pulmonary dysfunction. MII/bolus reflux, but not pH/acid reflux, was associated with pulmonary dysfunction in prelung transplant patients with IPF. MII-pH may be more valuable than pH testing alone in characterizing GER in IPF. © 2016 John Wiley & Sons Ltd.

  5. Electrical Impedance Tomography Technology

    Data.gov (United States)

    National Aeronautics and Space Administration — The goal for the Electrical Impedance Tomography Technology (EITT) project is to develop a reliable portable, lightweight device providing two-dimensional...

  6. Impedance and component heating

    CERN Document Server

    Métral, E; Mounet, N; Pieloni, T; Salvant, B

    2015-01-01

    The impedance is a complex function of frequency, which represents, for the plane under consideration (longitudinal, horizontal or vertical), the force integrated over the length of an element, from a “source” to a “test” wave, normalized by their charges. In general, the impedance in a given plane is a nonlinear function of the test and source transverse coordinates, but it is most of the time sufficient to consider only the first few linear terms. Impedances can influence the motion of trailing particles, in the longitudinal and in one or both transverse directions, leading to energy loss, beam instabilities, or producing undesirable secondary effects such as excessive heating of sensitive components at or near the chamber wall, called beam-induced RF heating. The LHC performance limitations linked to impedances encountered during the 2010-2012 run are reviewed and the currently expected situation during the HL-LHC era is discussed.

  7. Physical activity measured by accelerometry and its associations with cardiac structure and vascular function in young and middle-aged adults

    DEFF Research Database (Denmark)

    Andersson, Charlotte; Lyass, Asya; Larson, Martin G

    2015-01-01

    objective measures of moderate- to vigorous-intensity physical activity (MVPA, assessed by accelerometry) to cardiac and vascular indices in 2376 participants of the Framingham Heart Study third generation cohort (54% women, mean age 47 years). Using multivariable regression models, we related MVPA......BACKGROUND: Physical activity is associated with several health benefits, including lower cardiovascular disease risk. The independent influence of physical activity on cardiac and vascular function in the community, however, has been sparsely investigated. MEASURES AND RESULTS: We related...... to the following echocardiographic and vascular measures: left ventricular mass, left atrial and aortic root sizes, carotid-femoral pulse wave velocity, augmentation index, and forward pressure wave. Men and women engaged in MVPA 29.9±21.4 and 25.5±19.4 min/day, respectively. Higher values of MVPA (per 10-minute...

  8. Electrical impedance tomography: topology optimization

    International Nuclear Information System (INIS)

    Miranda, Lenine Campos

    2013-01-01

    The Electrical Impedance Tomography (EIT) is a study of body parts who use electric current. Is studied through computers resistance or conductivity of these parts, producing an image used for medical diagnosis. A body is wrapped in a blanket placed with small electrodes and receivers of electric current, potential difference. Based on data obtained from a series of measurements at the electrodes, one by one, sending and receiving, you can perform a numerical phantom, where each 'voxel' of the image formed computationally represents the impedance of biological tissue. In Brazil, studies on electrical impedance tomography (EIT) has not yet started. Such equipment are measured tensions - potential difference - between each electrode / sensor one by one, as a way to Simple Combinatorial Analysis. The sequence and the way it is measured strains are in the final image quality. Finite Element Method Interactive, whose algorithm is based on Dialectical Method. We use an initial function with the objective of maximizing the data quantitatively, for better qualitative analysis. Topology Optimization methods are used to improve the image reconstruction. Currently the study is quite primitive related to the theory that shows how to power the new science studied. The high quality images requires a difficulty in obtaining. This work is not intended for detailed for analysis in any tissue or organ specific, but in general terms. And the formation of the 2D image. 3D need a reconstructor to part. (author)

  9. 14CO2 labeling: a reliable technique for rapid measurement of total root exudation capacity and vascular sap flow in crops

    International Nuclear Information System (INIS)

    Singh, Bhupinder; Ahuja, Sumedha; Pandey, Renu; Singhal, R.K.

    2014-01-01

    Ability of roots to release organic compounds in its rhizosphere is known to improve plant available nutrients and reduces heavy metal toxicity by immobilization. It is regarded as an important determinant of micro nutrient deficiency tolerance in plants. Uptake of nutrients and translocation of photoassimilates, on the other hand are governed by the strength of the transpiration stream and sink demand respectively. Measurement of vascular sap flow, thus, is critical for understanding of the translocation efficiency and consequently the sink demand that keeps changing during the crop growth cycle. Measurement of the root exudation capacity and the vascular sap flow is cumbersome and time consuming. Since, the exudates released by the roots and the photosynthates translocated between the source and the sink are essentially carbon compounds, use of labeled carbon as tag could potentially be exploited for a rapid and reliable measurement of exudation and vascular sap flow in crop plants. We report here the experimental results involving 14 C labeling of groundnut, a legume crop, as 14 CO 2 generated by acidification of sodium bicarbonate. An additional factor of seed gamma irradiation was used to generate variability in the root exudation and the sap flow. The 14 C release by the roots was compared against the 14 C transport in the vascular sap. An experimental hypothesis that a higher 14 C level in the vascular sap would indicate a higher root release of carbon by the roots into the rhizosphere was verified. (author)

  10. In vivo imaging of twist drill drainage for subdural hematoma: a clinical feasibility study on electrical impedance tomography for measuring intracranial bleeding in humans.

    Science.gov (United States)

    Dai, Meng; Li, Bing; Hu, Shijie; Xu, Canhua; Yang, Bin; Li, Jianbo; Fu, Feng; Fei, Zhou; Dong, Xiuzhen

    2013-01-01

    Intracranial bleeding is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would largely reduce the rate of disability and mortality, and improve the prognosis of the patients. Electrical Impedance Tomography (EIT) can non-invasively image the internal resistivity distribution within a human body using a ring of external electrodes, and is thus a promising technique to promptly detect the occurrence of intracranial bleedings because blood differs from other brain tissues in resistivity. However, so far there is no experimental study that has determined whether the intracranial resistivity changes in humans could be repeatedly detected and imaged by EIT. Hence, we for the first time attempt to clinically validate this by in vivo imaging the influx and efflux of irrigating fluid (5% dextrose in water, D5W) during the twist-drill drainage operation for the patients with subdural hematoma (SDH). In this study, six patients (four male, two female) with subacute or chronic SDH received the surgical operation in order to evacuate the hematoma around subdural region, and EIT measurements were performed simultaneously on each patient's head. The results showed that the resistivity significantly increased on the corresponding position of EIT images during the influx of D5W and gradually decreased back to baseline during the efflux. In the quantitative analysis, the average resistivity values demonstrated the similar results and had highly linear correlation (R(2) = 0.93 ± 0.06) with the injected D5W volumes, as well as the area of the resistivity gain(R(2) = 0.94 ± 0.05). In conclusion, it was clinically validated that intracranial resistivity changes in humans were detectable and quantifiable by the EIT method. After further technical improvements, EIT has the great potential of being a routine neuroimaging tool for early detection of intracranial bleedings.

  11. In vivo imaging of twist drill drainage for subdural hematoma: a clinical feasibility study on electrical impedance tomography for measuring intracranial bleeding in humans.

    Directory of Open Access Journals (Sweden)

    Meng Dai

    Full Text Available Intracranial bleeding is one of the most severe medical emergencies in neurosurgery. Early detection or diagnosis would largely reduce the rate of disability and mortality, and improve the prognosis of the patients. Electrical Impedance Tomography (EIT can non-invasively image the internal resistivity distribution within a human body using a ring of external electrodes, and is thus a promising technique to promptly detect the occurrence of intracranial bleedings because blood differs from other brain tissues in resistivity. However, so far there is no experimental study that has determined whether the intracranial resistivity changes in humans could be repeatedly detected and imaged by EIT. Hence, we for the first time attempt to clinically validate this by in vivo imaging the influx and efflux of irrigating fluid (5% dextrose in water, D5W during the twist-drill drainage operation for the patients with subdural hematoma (SDH. In this study, six patients (four male, two female with subacute or chronic SDH received the surgical operation in order to evacuate the hematoma around subdural region, and EIT measurements were performed simultaneously on each patient's head. The results showed that the resistivity significantly increased on the corresponding position of EIT images during the influx of D5W and gradually decreased back to baseline during the efflux. In the quantitative analysis, the average resistivity values demonstrated the similar results and had highly linear correlation (R(2 = 0.93 ± 0.06 with the injected D5W volumes, as well as the area of the resistivity gain(R(2 = 0.94 ± 0.05. In conclusion, it was clinically validated that intracranial resistivity changes in humans were detectable and quantifiable by the EIT method. After further technical improvements, EIT has the great potential of being a routine neuroimaging tool for early detection of intracranial bleedings.

  12. Effect of intravenous contrast agent volume on colorectal cancer vascular parameters as measured by perfusion computed tomography

    International Nuclear Information System (INIS)

    Goh, V.; Bartram, C.; Halligan, S.

    2009-01-01

    Aim: To determine the effect of two different contrast agent volumes on quantitative and semi-quantitative vascular parameters as measured by perfusion computed tomography (CT) in colorectal cancer. Materials and methods: Following ethical approval and informed consent, eight prospectively recruited patients with proven colorectal adenocarcinoma underwent two separate perfusion CT studies on the same day after (a) 100 ml and (b) 50 ml of a 340 mg/ml iodinated contrast medium, respectively. Quantitative (blood volume, blood flow, permeability surface area product) and semi-quantitative (peak enhancement, time to peak enhancement) tumour vascular parameters were determined using commercial software based on distributed parameter analysis and compared using t-testing. Results: Tumour blood volume, blood flow, and permeability surface area product were not substantially different following the injection of 100 ml and 50 ml contrast medium: 6.12 versus 6.23 ml/100 g tissue; 73.4 versus 71.3 ml/min/100 g tissue; 15.6 versus 15.3 ml/min/100 g tissue for 100 and 50 ml, respectively; p > 0.05. Tumour peak enhancement and time to peak were significantly greater following the injection of 100 ml versus 50 ml contrast medium: 41.2 versus 28.5 HU; 16.1 versus 11.8 s for 100 ml and 50 ml, respectively; p = 0.002; p = 0.0003. Conclusion: Quantitative parameters do not appear to change substantially with a higher contrast agent volume suggesting a combined diagnostic staging-perfusion CT study following a single injection is feasible for colorectal cancer

  13. Diagnostic Significance of Measuring Vascular Endothelial Growth Factor for the Differentiation between Malignant and Tuberculous Pleural Effusion.

    Science.gov (United States)

    Kim, Hak-Ryul; Kim, Byoung-Ryun; Park, Rae-Kil; Yoon, Kwon-Ha; Jeong, Eun-Taik; Hwang, Ki-Eun

    2017-06-01

    Malignancy and tuberculosis are common causes of lymphocytic exudative pleural effusion. However, it is occasionally difficult to differentiate malignant pleural effusion from tuberculous pleural effusion. Vascular endothelial growth factor (VEGF) is a critical cytokine in the pathogenesis of malignant pleural effusion. Endocan is a dermatan sulfate proteoglycan that is secreted by endothelial cells. Importantly, endocan mediates the vascular growth-promoting action of VEGF. The aim of this study was to evaluate the diagnostic significance of VEGF and endocan in pleural effusion. We thus measured the levels of VEGF and endocan in the pleural effusion and serum samples of patients with lung cancer (n = 59) and those with tuberculosis (n = 32) by enzyme-linked immunosorbent assay. Lung cancer included 40 cases of adenocarcinoma, 13 of squamous cell carcinoma, and 6 of small cell carcinoma. Pleural effusion VEGF levels were significantly higher in the malignant group than in the tuberculosis group (2,091.47 ± 1,624.80 pg/mL vs. 1,291.05 ± 1,100.53 pg/mL, P pleural effusion endocan levels were similar between the two groups (1.22 ± 0.74 ng/mL vs. 0.87 ± 0.53 ng/mL). The areas under the curve of VEGF and endocan were 0.73 and 0.52, respectively. Notably, the VEGF levels were similar in malignant pleural effusion, irrespective of the histological type of lung cancer. Moreover, no significant difference was found in the serum VEGF and endocan levels between patients with lung cancer and those with tuberculosis. In conclusion, high VEGF levels in pleural effusion are suggestive of malignant pleural effusion.

  14. Identification of irradiated potatoes by impedance

    International Nuclear Information System (INIS)

    Singh, Rita; Singh, Antaryami; Wadhawan, A.K.

    1997-01-01

    The electrical impedance of potatoes irradiated at 60, 90, 150 and 1000 Gy was measured using various frequencies of alternating current. The impedance of the irradiated potatoes was higher than the unirradiated potatoes particularly in the frequency range of 100 Hz to 10 kHz. The ratio of the impedance at 5 kHz to that at 50 Hz (Z5k/Z50) was found to be the best indicator for detection of radiation treatment. (author). 4 refs., 2 figs

  15. Small-signal Loudspeaker Impedance Emulator

    DEFF Research Database (Denmark)

    Knott, Arnold; Iversen, Niels Elkjær

    2014-01-01

    Specifying the performance of audio ampliers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by the mechanical resonance between the mass of the diaphragm and the compliance of its' suspension which vary from...... driver to driver. Therefore a loudspeaker emulator capable of adjusting its' impedance to a given driver is in need for measurement purposes. This paper proposes a loudspeaker emulator circuit for small signals. Simulations and experimental results are compared and show that it is possible to emulate...... the loudspeaker impedance with an electric circuit and that its' resonance frequency can be changed by tuning two resistors....

  16. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately simulated by the finite-element analysis and the result agrees quantitatively to the experimental data on a series of thin-film dielectric samples. The tapping mode microwave imaging is also superior to the contact mode in that the thermal drift in a long time scale is totally eliminated and an absolute measurement on the dielectric properties is possible. We demonstrated tapping images on working nanodevices, and the data are consistent with the transport results. © 2009 American Institute of Physics.

  17. Can the green laser doppler measure skin-nutritive perfusion in patients with peripheral vascular disease?

    NARCIS (Netherlands)

    Ubbink, D. T.; Tulevski, I. I.; Jacobs, M. J.

    2000-01-01

    The recently developed green laser (GL; wavelength 543 nm) is thought to measure perfusion derived from a more superficial skin layer than does the standard near-infrared laser (RL; wavelength 780 nm). These lasers were used to investigate the disturbances in the different layers of skin perfusion

  18. Electrothermal impedance spectroscopy measurement on high power LiMO2/Li4Ti5O12 battery cell with low bandwidth test setup

    DEFF Research Database (Denmark)

    Swierczynski, Maciej Jozef; Stroe, Daniel Loan; Stanciu, Tiberiu

    2015-01-01

    be executed on-line (e.g. in the electric vehicle Battery Management System). The Electrothermal Impedance Spectroscopy (ETIS) can be used as a relatively simple and fast method for non-destructive parametrization of the battery thermal models. However, the ETIS requires expensive galvanostat with high...

  19. Interarm blood pressure difference in people with diabetes: measurement and vascular and mortality implications: a cohort study.

    Science.gov (United States)

    Clark, Christopher E; Steele, Anna M; Taylor, Rod S; Shore, Angela C; Ukoumunne, Obioha C; Campbell, John L

    2014-06-01

    Differences in blood pressure between arms are associated with vascular disease and increased mortality; this has not been reported in diabetes. We explored these associations, and assessed reference standard and pragmatic measurement techniques, in people with diabetes and in nondiabetic controls. A prospective cohort study in Devon, England, recruited 727 people with type 1 or type 2 diabetes and 285 nondiabetic controls. Simultaneous repeated measurements of bilateral blood pressure were made at recruitment. Data were used to inform a pragmatic measurement strategy. Interarm differences were examined for cross-sectional associations with target organ disease and prospective mortality associations (median follow-up 52 months). We found 8.6% of participants with diabetes and 2.9% of controls had systolic interarm differences ≥10 mmHg. Single pairs of blood pressure measurements had high negative predictive values (97-99%) for excluding interarm differences. Systolic interarm differences ≥10 mmHg in diabetes were associated with peripheral arterial disease (odds ratio [OR] 3.4 [95% CI 1.2-9.3]). Differences ≥15 mmHg were associated with diabetic retinopathy (OR 5.7 [1.5-21.6]) and chronic kidney disease (OR 7.0 [1.7-29.8]). Systolic interarm differences were associated prospectively with increased cardiovascular mortality: hazard ratios 3.5 (1.0-13.0) for ≥10 mmHg and 9.0 (2.0-41.0) for ≥15 mmHg. Blood pressure should be measured in both arms during initial assessment in diabetes. Systolic interarm differences can be excluded with a single pair of measurements. In the population with diabetes, systolic differences may be associated with an increased risk of morbidity and mortality. © 2014 by the American Diabetes Association.

  20. Impeded Dark Matter

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, Joachim; Liu, Jia [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Slatyer, Tracy R. [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States); Wang, Xiao-Ping [PRISMA Cluster of Excellence & Mainz Institute for Theoretical Physics,Johannes Gutenberg University,Staudingerweg 7, 55099 Mainz (Germany); Xue, Wei [Center for Theoretical Physics, Massachusetts Institute of Technology,Cambridge, MA 02139 (United States)

    2016-12-12

    We consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario “Impeded Dark Matter”. We demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.

  1. Impeded Dark Matter

    International Nuclear Information System (INIS)

    Kopp, Joachim; Liu, Jia; Slatyer, Tracy R.; Wang, Xiao-Ping; Xue, Wei

    2016-01-01

    We consider dark matter models in which the mass splitting between the dark matter particles and their annihilation products is tiny. Compared to the previously proposed Forbidden Dark Matter scenario, the mass splittings we consider are much smaller, and are allowed to be either positive or negative. To emphasize this modification, we dub our scenario “Impeded Dark Matter”. We demonstrate that Impeded Dark Matter can be easily realized without requiring tuning of model parameters. For negative mass splitting, we demonstrate that the annihilation cross-section for Impeded Dark Matter depends linearly on the dark matter velocity or may even be kinematically forbidden, making this scenario almost insensitive to constraints from the cosmic microwave background and from observations of dwarf galaxies. Accordingly, it may be possible for Impeded Dark Matter to yield observable signals in clusters or the Galactic center, with no corresponding signal in dwarfs. For positive mass splitting, we show that the annihilation cross-section is suppressed by the small mass splitting, which helps light dark matter to survive increasingly stringent constraints from indirect searches. As specific realizations for Impeded Dark Matter, we introduce a model of vector dark matter from a hidden SU(2) sector, and a composite dark matter scenario based on a QCD-like dark sector.

  2. Blood flow velocity measurements in chicken embryo vascular network via PIV approach

    Science.gov (United States)

    Kurochkin, Maxim A.; Stiukhina, Elena S.; Fedosov, Ivan V.; Tuchin, Valery V.

    2018-04-01

    A method for measuring of blood velocity in the native vasculature of a chick embryo by the method of micro anemometry from particle images (μPIV) is improved. A method for interrogation regions sorting by the mask of the vasculature is proposed. A method for sorting of the velocity field of capillary blood flow is implemented. The in vitro method was evaluated for accuracy in a glass phantom of a blood vessel with a diameter of 50 μm and in vivo on the bloodstream of a chicken embryo, by comparing the transverse profile of the blood velocity obtained by the PIV method with the theoretical Poiseuille laminar flow profile.

  3. Particle image velocimetry measurements in an anatomical vascular model fabricated using inkjet 3D printing

    Science.gov (United States)

    Aycock, Kenneth I.; Hariharan, Prasanna; Craven, Brent A.

    2017-11-01

    For decades, the study of biomedical fluid dynamics using optical flow visualization and measurement techniques has been limited by the inability to fabricate transparent physical models that realistically replicate the complex morphology of biological lumens. In this study, we present an approach for producing optically transparent anatomical models that are suitable for particle image velocimetry (PIV) using a common 3D inkjet printing process (PolyJet) and stock resin (VeroClear). By matching the index of refraction of the VeroClear material using a room-temperature mixture of water, sodium iodide, and glycerol, and by printing the part in an orientation such that the flat, optical surfaces are at an approximately 45° angle to the build plane, we overcome the challenges associated with using this 3D printing technique for PIV. Here, we summarize our methodology and demonstrate the process and the resultant PIV measurements of flow in an optically transparent anatomical model of the human inferior vena cava.

  4. Superconducting active impedance converter

    International Nuclear Information System (INIS)

    Ginley, D.S.; Hietala, V.M.; Martens, J.S.

    1993-01-01

    A transimpedance amplifier for use with high temperature superconducting, other superconducting, and conventional semiconductors allows for appropriate signal amplification and impedance matching to processing electronics. The amplifier incorporates the superconducting flux flow transistor into a differential amplifier configuration which allows for operation over a wide temperature range, and is characterized by high gain, relatively low noise, and response times less than 200 picoseconds over at least a 10-80 K. temperature range. The invention is particularly useful when a signal derived from either far-IR focal plane detectors or from Josephson junctions is to be processed by higher signal/higher impedance electronics, such as conventional semiconductor technology. 12 figures

  5. Mechanical Impedance Modeling of Human Arm: A survey

    Science.gov (United States)

    Puzi, A. Ahmad; Sidek, S. N.; Sado, F.

    2017-03-01

    Human arm mechanical impedance plays a vital role in describing motion ability of the upper limb. One of the impedance parameters is stiffness which is defined as the ratio of an applied force to the measured deformation of the muscle. The arm mechanical impedance modeling is useful in order to develop a better controller for system that interacts with human as such an automated robot-assisted platform for automated rehabilitation training. The aim of the survey is to summarize the existing mechanical impedance models of human upper limb so to justify the need to have an improved version of the arm model in order to facilitate the development of better controller of such systems with ever increase in complexity. In particular, the paper will address the following issue: Human motor control and motor learning, constant and variable impedance models, methods for measuring mechanical impedance and mechanical impedance modeling techniques.

  6. Assessment of tissue oxygen saturation during a vascular occlusion test using near-infrared spectroscopy: the role of probe spacing and measurement site studied in healthy volunteers

    NARCIS (Netherlands)

    Bezemer, R.; Lima, A.; Myers, D.; Klijn, E.; Heger, M.; Goedhart, P.T.; Bakker, J.; Ince, C.

    2009-01-01

    INTRODUCTION: To assess potential metabolic and microcirculatory alterations in critically ill patients, near-infrared spectroscopy (NIRS) has been used, in combination with a vascular occlusion test (VOT), for the non-invasive measurement of tissue oxygen saturation (StO2), oxygen consumption, and

  7. Broadband electrical impedance matching for piezoelectric ultrasound transducers.

    Science.gov (United States)

    Huang, Haiying; Paramo, Daniel

    2011-12-01

    This paper presents a systematic method for designing broadband electrical impedance matching networks for piezoelectric ultrasound transducers. The design process involves three steps: 1) determine the equivalent circuit of the unmatched piezoelectric transducer based on its measured admittance; 2) design a set of impedance matching networks using a computerized Smith chart; and 3) establish the simulation model of the matched transducer to evaluate the gain and bandwidth of the impedance matching networks. The effectiveness of the presented approach is demonstrated through the design, implementation, and characterization of impedance matching networks for a broadband acoustic emission sensor. The impedance matching network improved the power of the acquired signal by 9 times.

  8. Nitrosylated hemoglobin levels in human venous erythrocytes correlate with vascular endothelial function measured by digital reactive hyperemia.

    Directory of Open Access Journals (Sweden)

    Irina I Lobysheva

    Full Text Available Impaired nitric oxide (NO-dependent endothelial function is associated with the development of cardiovascular diseases. We hypothesized that erythrocyte levels of nitrosylated hemoglobin (HbNO-heme may reflect vascular endothelial function in vivo. We developed a modified subtraction method using Electron Paramagnetic Resonance (EPR spectroscopy to identify the 5-coordinate α-HbNO (HbNO concentration in human erythrocytes and examined its correlation with endothelial function assessed by peripheral arterial tonometry (PAT. Changes in digital pulse amplitude were measured by PAT during reactive hyperemia following brachial arterial occlusion in a group of healthy volunteers (50 subjects. Erythrocyte HbNO levels were measured at baseline and at the peak of hyperemia. We digitally subtracted an individual model EPR signal of erythrocyte free radicals from the whole EPR spectrum to unmask and quantitate the HbNO EPR signals.Mean erythrocyte HbNO concentration at baseline was 219+/-12 nmol/L (n = 50. HbNO levels and reactive hyperemia (RH indexes were higher in female (free of contraceptive pills than male subjects. We observed a dynamic increase of HbNO levels in erythrocytes isolated at 1-2 min of post-occlusion hyperemia (120+/-8% of basal levels; post-occlusion HbNO levels were correlated with basal levels. Both basal and post-occlusion HbNO levels were significantly correlated with reactive hyperemia (RH indexes (r = 0.58; P<0.0001 for basal HbNO.The study demonstrates quantitative measurements of 5-coordinate α-HbNO in human venous erythrocytes, its dynamic physiologic regulation and correlation with endothelial function measured by tonometry during hyperemia. This opens the way to further understanding of in vivo determinants of NO bioavailability in human circulation.

  9. Loudspeaker impedance emulator for multi resonant systems

    DEFF Research Database (Denmark)

    Iversen, Niels Elkjær; Knott, Arnold

    2015-01-01

    Specifying the performance of audio amplifiers is typically done by playing sine waves into a pure ohmic load. However real loudspeaker impedances are not purely ohmic but characterised by its electrical, mechanical and acoustical properties. Therefore a loudspeaker emulator capable of adjusting...... its impedance to that of a given loudspeaker is desired for measurement purposes. An adjustable RLC based emulator is implemented with switch controlled capacitors, air gap controlled inductors and potentiometers. Calculations and experimental results are compared and show that it is possible...... to emulate the loudspeaker impedance infinite baffle-, closed box- and the multi resonant vented box-loudspeaker by tuning the component values in the proposed circuit. Future work is outlined and encourage that the proposed impedance emulator is used as part of a control circuit in a switch-mode based...

  10. Modeling degradation in SOEC impedance spectra

    DEFF Research Database (Denmark)

    Jensen, Søren Højgaard; Hauch, Anne; Knibbe, Ruth

    2013-01-01

    Solid oxide cell (SOC) performance is limited by various processes. One way to investigate these processes is by electrochemical impedance spectroscopy. In order to quantify and characterize the processes, an equivalent circuit can be used to model the SOC impedance spectra (IS). Unfortunately......, the optimal equivalent circuit is often unknown and to complicate matters further, several processes contribute to the SOC impedance - making detailed process characterization difficult. In this work we analyze and model a series of IS measured during steam electrolysis operation of an SOC. During testing......, degradation is only observed in the Ni/YSZ electrode and not in the electrolyte or the LSM/YSZ electrode. A batch fit of the differences between the IS shows that a modified Gerischer element provides a better fit to the Ni/YSZ electrode impedance than the frequently used RQ element - albeit neither...

  11. Act No. 23.592 adopting measures against those who arbitrarily impede the full exercise of fundamental rights and guarantees recognized in the National Constitution, 23 August 1988.

    Science.gov (United States)

    1988-01-01

    This Act provides that whoever arbitrarily impedes, obstructs, restricts, or in any other way limits the full exercise on an equal basis of fundamental rights and guarantees recognized by the National Constitution of Argentina will be obligated, at the request of the injured person, to render the discriminatory act without effect or cease in its realization and repair the moral and material damage that has resulted. To be particularly scrutinized are discriminatory acts or omissions undertaken for sexual reasons, among others. full text

  12. Impaired bolus clearance in combined high-resolution esophageal manometry and impedance measurement helps to differentiate between esophagogastric junction outflow obstruction and achalasia.

    Science.gov (United States)

    Zizer, Eugen; Seufferlein, Thomas; Hänle, Mark Martin

    2017-02-01

    Introduction and aims  High-resolution esophageal manometry (HRM) has improved the diagnostic work-up of esophageal motility disorders. Simultaneous evaluation of bolus clearance delivers useful information about the function of tubular esophagus. We assessed bolus clearance in a combined HRM-impedance examination for esophagogastric junction outflow obstruction (EGJOO) in comparison to achalasia patients. The collected data were assessed in a retrospective analysis. Patients and methods  After gastroscopy excluded a mechanical esophageal or gastric obstruction, 142 consecutive patients underwent combined HRM-impedance examination. The assessment and interpretation of the manometry results were done according to the Chicago Classification of esophageal motility disorders v3.0. After classifying the motility disorder, the evaluation of bolus clearance was done according to published studies. Results  All patients with achalasia (n = 24) showed a significantly impaired bolus clearance (achalasia cases. This might be helpful as an additional tool to differentiate between achalasia and EGJOO patients. Furthermore, the role of the combined impedance-HRM investigation for early diagnosis of achalasia in "pre-achalasia" condition or in evaluation of potential progress of EGJOO to achalasia should be evaluated in a prospective study. © Georg Thieme Verlag KG Stuttgart · New York.

  13. Color Doppler imaging and measurements of intraovarian and intrauterine vascularization on basal ultrasound examination in spontaneous ovulatory and anovulatory cycles

    Directory of Open Access Journals (Sweden)

    Kutlešić Ranko

    2008-01-01

    Full Text Available Background/Aim. Any organs functioning directly depends on vascularization. It applies also to the uterus and ovary which go through changes of vascularization during a menstruation cycle. The aim of this investigation was to determine differences in intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4 between spontaneous ovulatory and anovulatory cycles. Methods. This prospective clinical investigation included 205 patients divided into two groups: with ovulatory and with anovulatory cycles. Results. Resistance to ovarian arterioral stromal blood flow was significantly lower in the patients with ovulatory cycles (pulsatile index - PI 0.97 ± 0.4 vs 1.93 ± 1.37; p = 0.001737; and (resistance index - RI 0.55 ± 0.12 vs 0.68 ± 0.14; p = 0.040033. There were no statistically significant differences in arcuate arterioral blood flow in the pateints with ovulatory and anovulatory cycles (PI 1.21 ± 0.34 vs 61 ± 0,61 p = 0.136161 and RI 0.64 ± 0.11 vs 0.74 ± 0.07; p = 0.136649. The patients with ovulatory cycles had lower uterine radial arterioral blood flow than the patients with anovulatory cycles (PI 1.001 ± 0.22 vs 1.61 ± 0.23 p = 0.007501 and RI 0.55 ± 0.08 vs 0.71 ± 0.12; p = 0,0460113. The patients with ovulatory cycles had lower subendometrial arterioral blood flow resistance (PI 0.69 ± 0.19 vs 1.385±0.09; p = 0.00622 and RI 0.44 ± 0.09 vs 0.65 ± 0.02; p = 0.027458. Conclusion. Color Doppler ultrasuond imaging and measurements of intrauterine and ovarian stromal arterioral blood flow on basal ultrasound examination (day 2-4, showed lower resistance to blood flow in ovulatory than in anovulatory cycles.

  14. Impedance pattern of vaginal and vestibular mucosa in cyclic goats

    Directory of Open Access Journals (Sweden)

    Ivo Křivánek

    2008-01-01

    Full Text Available The changes of vaginal and vestibular impedance during the oestrous cycle in goats were examined. The onset of oestrus was teased with a buck once a day during the experiment. Impedance was mea­sured by a four-terminal method. The vaginal impedance was recorded under slight pressure of electrodes to the vaginal dorsal wall at the cervix. The vestibular impedance was recorded under slight pressure of electrodes to the vestibular dorsal wall 5 cm from the vulva and at the vulva. The im­pe­dan­ce was measured once a day from 4 days before the expected oestrus to 6 days after onset of oestrus. The vaginal impedance at the cervix decreased during pro-oestrus (P < 0.01 and increased du­ring oestrus (P < 0.01. The vestibular impedance 5 cm from the vulva decreased during pro-oestrus (P < 0.01 and increased after oestrus (P < 0.01. The decrease of vaginal impedance during peri-oestrus was nearly twofold in comparison with the vestibular impedance 5 cm from the vulva. No sig­ni­fi­cant decrease of the vestibular impedance at the vulva was found during the oestrous cycle. The results indicate that the vaginal impedance at the cervix and vestibular impedance 5 cm from the vulva measured by means of a four-terminal method during the oestrous cycle display cyclic changes that are closely related to the oestrous behaviour of goats.

  15. Measurement of vascular wall attenuation: Comparison of CT angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro

    International Nuclear Information System (INIS)

    Suzuki, Shigeru; Machida, Haruhiko; Tanaka, Isao; Ueno, Eiko

    2012-01-01

    Objectives: To compare the performance of model-based iterative reconstruction (MBIR) with that of standard filtered back projection (FBP) for measuring vascular wall attenuation. Study design: After subjecting 9 vascular models (actual attenuation value of wall, 89 HU) with wall thickness of 0.5, 1.0, or 1.5 mm that we filled with contrast material of 275, 396, or 542 HU to scanning using 64-detector computed tomography (CT), we reconstructed images using MBIR and FBP (Bone, Detail kernels) and measured wall attenuation at the center of the wall for each model. We performed attenuation measurements for each model and additional supportive measurements by a differentiation curve. We analyzed statistics using analyzes of variance with repeated measures. Results: Using the Bone kernel, standard deviation of the measurement exceeded 30 HU in most conditions. In measurements at the wall center, the attenuation values obtained using MBIR were comparable to or significantly closer to the actual wall attenuation than those acquired using Detail kernel. Using differentiation curves, we could measure attenuation for models with walls of 1.0- or 1.5-mm thickness using MBIR but only those of 1.5-mm thickness using Detail kernel. We detected no significant differences among the attenuation values of the vascular walls of either thickness (MBIR, P = 0.1606) or among the 3 densities of intravascular contrast material (MBIR, P = 0.8185; Detail kernel, P = 0.0802). Conclusions: Compared with FBP, MBIR reduces both reconstruction blur and image noise simultaneously, facilitates recognition of vascular wall boundaries, and can improve accuracy in measuring wall attenuation.

  16. Measurement of vascular wall attenuation: comparison of CT angiography using model-based iterative reconstruction with standard filtered back-projection algorithm CT in vitro.

    Science.gov (United States)

    Suzuki, Shigeru; Machida, Haruhiko; Tanaka, Isao; Ueno, Eiko

    2012-11-01

    To compare the performance of model-based iterative reconstruction (MBIR) with that of standard filtered back projection (FBP) for measuring vascular wall attenuation. After subjecting 9 vascular models (actual attenuation value of wall, 89 HU) with wall thickness of 0.5, 1.0, or 1.5 mm that we filled with contrast material of 275, 396, or 542 HU to scanning using 64-detector computed tomography (CT), we reconstructed images using MBIR and FBP (Bone, Detail kernels) and measured wall attenuation at the center of the wall for each model. We performed attenuation measurements for each model and additional supportive measurements by a differentiation curve. We analyzed statistics using analyzes of variance with repeated measures. Using the Bone kernel, standard deviation of the measurement exceeded 30 HU in most conditions. In measurements at the wall center, the attenuation values obtained using MBIR were comparable to or significantly closer to the actual wall attenuation than those acquired using Detail kernel. Using differentiation curves, we could measure attenuation for models with walls of 1.0- or 1.5-mm thickness using MBIR but only those of 1.5-mm thickness using Detail kernel. We detected no significant differences among the attenuation values of the vascular walls of either thickness (MBIR, P=0.1606) or among the 3 densities of intravascular contrast material (MBIR, P=0.8185; Detail kernel, P=0.0802). Compared with FBP, MBIR reduces both reconstruction blur and image noise simultaneously, facilitates recognition of vascular wall boundaries, and can improve accuracy in measuring wall attenuation. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  17. VISUALIZATION OF BIOLOGICAL TISSUE IMPEDANCE PARAMETERS

    Directory of Open Access Journals (Sweden)

    V. I. Bankov

    2016-01-01

    Full Text Available Objective. Investigation the opportunity for measurement of biological tissue impedance to visualize its parameters.Materials and methods. Studies were undertook on the experimental facility, consists of registrating measuring cell, constructed from flat inductors system, formed in oscillatory circuit, herewith investigated biological tissue is the part of this oscillatory circuit. An excitation of oscillatory circuit fulfilled by means of exciter inductor which forms impulse complex modulated electromagnetic field (ICM EMF. The measurement process and visualizations provided by set of certificated instruments: a digital oscillograph AKTAKOM ADS-2221MV, a digital generator АКТАКОМ AWG-4150 (both with software and a gauge RLC E7-22. Comparative dynamic studies of fixed volume and weight pig’s blood, adipose tissue, muscular tissue impedance were conducted by contact versus contactless methods. Contactless method in contrast to contact method gives opportunity to obtain the real morphological visualization of biological tissue irrespective of their nature.Results. Comparison of contact and contactless methods of impedance measurement shows that the inductance to capacitance ratio X(L / X(C was equal: 17 – for muscular tissue, 4 – for blood, 1 – for adipose tissue. It demonstrates the technical correspondence of both impedance registration methods. If propose the base relevance of X (L and X (C parameters for biological tissue impedance so contactless measurement method for sure shows insulating properties of adipose tissue and high conductivity for blood and muscular tissue in fixed volume-weight parameters. Registration of biological tissue impedance complex parameters by contactless method with the help of induced ICM EMF in fixed volume of biological tissue uncovers the most important informative volumes to characterize morphofunctional condition of biological tissue namely X (L / X (C.Conclusion. Contactless method of biological

  18. Vascular diameter measurement in CT angiography: comparison of model-based iterative reconstruction and standard filtered back projection algorithms in vitro.

    Science.gov (United States)

    Suzuki, Shigeru; Machida, Haruhiko; Tanaka, Isao; Ueno, Eiko

    2013-03-01

    The purpose of this study was to evaluate the performance of model-based iterative reconstruction (MBIR) in measurement of the inner diameter of models of blood vessels and compare performance between MBIR and a standard filtered back projection (FBP) algorithm. Vascular models with wall thicknesses of 0.5, 1.0, and 1.5 mm were scanned with a 64-MDCT unit and densities of contrast material yielding 275, 396, and 542 HU. Images were reconstructed images by MBIR and FBP, and the mean diameter of each model vessel was measured by software automation. Twenty separate measurements were repeated for each vessel, and variance among the repeated measures was analyzed for determination of measurement error. For all nine model vessels, CT attenuation profiles were compared along a line passing through the luminal center on axial images reconstructed with FBP and MBIR, and the 10-90% edge rise distances at the boundary between the vascular wall and the lumen were evaluated. For images reconstructed with FBP, measurement errors were smallest for models with 1.5-mm wall thickness, except those filled with 275-HU contrast material, and errors grew as the density of the contrast material decreased. Measurement errors with MBIR were comparable to or less than those with FBP. In CT attenuation profiles of images reconstructed with MBIR, the 10-90% edge rise distances at the boundary between the lumen and vascular wall were relatively short for each vascular model compared with those of the profile curves of FBP images. MBIR is better than standard FBP for reducing reconstruction blur and improving the accuracy of diameter measurement at CT angiography.

  19. Effects of breathing a hyperoxic hypercapnic gas mixture on blood oxygenation and vascularity of head-and-neck tumors as measured by magnetic resonance imaging

    International Nuclear Information System (INIS)

    Rijpkema, Mark; Kaanders, Johannes H.A.M.; Joosten, Frank; Kogel, Albert J. van der; Heerschap, Arend

    2002-01-01

    Purpose: For head-and-neck tumors, breathing a hyperoxic hypercapnic gas mixture and administration of nicotinamide has been shown to result in a significantly improved tumor response to accelerated radiotherapy (ARCON, Accelerated Radiotherapy with CarbOgen and Nicotinamide). This may be caused by improved tumor oxygenation, possibly mediated by vascular effects. In this study, both blood oxygenation and vascular effects of breathing a hyperoxic hypercapnic gas mixture (98% O 2 +2% CO 2 ) were assessed by magnetic resonance imaging (MRI) in patients with head-and-neck tumors. Methods and Materials: Tumor vascularity and oxygenation were investigated by dynamic gadolinium contrast-enhanced MRI and blood oxygen level dependent (BOLD) MRI, respectively. Eleven patients with primary head-and-neck tumors were each measured twice; with and without breathing the hyperoxic hypercapnic gas mixture. Results: BOLD MR imaging revealed a significant increase of the MRI time constant of transverse magnetization decay (T 2 *) in the tumor during hypercapnic hyperoxygenation, which correlates to a decrease of the deoxyhemoglobin concentration. No changes in overall tumor vascularity were observed, as measured by the gadolinium contrast uptake rate in the tumor. Conclusion: Breathing a hyperoxic hypercapnic gas mixture improves tumor blood oxygenation in patients with head-and-neck tumors, which may contribute to the success of the ARCON therapy

  20. Tapping mode microwave impedance microscopy

    KAUST Repository

    Lai, K.; Kundhikanjana, W.; Peng, H.; Cui, Y.; Kelly, M. A.; Shen, Z. X.

    2009-01-01

    We report tapping mode microwave impedance imaging based on atomic force microscope platforms. The shielded cantilever probe is critical to localize the tip-sample interaction near the tip apex. The modulated tip-sample impedance can be accurately

  1. Pulmonary vascular imaging

    International Nuclear Information System (INIS)

    Fedullo, P.F.; Shure, D.

    1987-01-01

    A wide range of pulmonary vascular imaging techniques are available for the diagnostic evaluation of patients with suspected pulmonary vascular disease. The characteristics of any ideal technique would include high sensitivity and specificity, safety, simplicity, and sequential applicability. To date, no single technique meets these ideal characteristics. Conventional pulmonary angiography remains the gold standard for the diagnosis of acute thromboembolic disease despite the introduction of newer techniques such as digital subtraction angiography and magnetic resonance imaging. Improved noninvasive lower extremity venous testing methods, particularly impedance plethysmography, and ventilation-perfusion scanning can play significant roles in the noninvasive diagnosis of acute pulmonary emboli when properly applied. Ventilation-perfusion scanning may also be useful as a screening test to differentiate possible primary pulmonary hypertension from chronic thromboembolic pulmonary hypertension. And, finally, angioscopy may be a useful adjunctive technique to detect chronic thromboembolic disease and determine operability. Optimal clinical decision-making, however, will continue to require the proper interpretation of adjunctive information obtained from the less-invasive techniques, applied with an understanding of the natural history of the various forms of pulmonary vascular disease and with a knowledge of the capabilities and shortcomings of the individual techniques

  2. Simultaneous Determination of Electrochemical Impedance of Lithium-ion Rechargeable Batteries with Measurement of Charge-discharge Curves by Wavelet Transformation

    International Nuclear Information System (INIS)

    Itagaki, Masayuki; Ueno, Masaki; Hoshi, Yoshinao; Shitanda, Isao

    2017-01-01

    Highlights: • Wavelet transformation (WT) was used to obtain electrochemical impedance (EI) from time domain data. • Complex Morlet mother wavelet was employed to transform current and voltage time series from time domain to frequency domain. • An analytical method to determine EI of LIRB at arbitrary state of charge was proposed. • EI of LIRB was determined at arbitrary state of charge without stopping galvanostatic polarization for charge and discharge. - Abstract: A new analytical method was developed to determine the electrochemical impedance of lithium-ion rechargeable batteries (LIRB) at an arbitrary state of charge (SOC). Wavelet transformation (WT) is one of the waveform analysis methods, which allows the determination of frequency domain data as a function of time. The frequency domain data are obtained by convolution integral of a mother wavelet and original time domain data via the WT. A complex Morlet mother wavelet is used to obtain the complex number data in the frequency domain. The time series data of input current and output voltage signals are recorded by superimposing the double pulse current as an input signal to constant charge current for the charge of LIRB without stopping galvanostatic polarization. The double pulse current is composed of symmetrical positive and negative square waves. In this case, the SOC of LIRB is not affected by the input signal because the total amount of charge calculated from double pulse current is 0C. The impedance spectrum of LIRB at SOC 25% is determined in the frequency range from 0.1 to 100 Hz during charge/discharge cycles without stopping galvanostatic polarization for the charge/discharge.

  3. SSC kicker impedances

    International Nuclear Information System (INIS)

    Colton, E.P.; Wang, T.F.

    1985-01-01

    The longitudinal and transverse complex impedances Z/sub l//n and Z/sub t/, respectively, have been calculated for both the SSC injection and abort kickers. The calculations assumed that no attempt was made to shield the beam from the kickers. We took the injection and abort kickers to be as specified. The injection kickers were ferrite with a single-turn design, and the abort kickers were of a ''window-frame design'' with tape wound cores

  4. A-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Blaabjerg, Frede; Galigekere, Veda Prakash

    2016-01-01

    A novel A-source impedance network is proposed in this letter. The A-source impedance network uses an autotransformer for realizing converters for any application that demand a very high dc voltage gain. The network utilizes a minimal turns ratio compared to other Magnetically Coupled Impedance S...

  5. Impedance analysis of subwoofer systems

    NARCIS (Netherlands)

    Berkhoff, Arthur P.

    The electrical impedance of four low-frequency loudspeaker systems is analyzed. The expression for this impedance is obtained directly from the acoustical analogous circuit. Formulas are derived for calculating the small-signal parameters from the frequencies of impedance minima and maxima of two

  6. Impedance Spectroscopy of Dielectrics and Electronic Conductors

    DEFF Research Database (Denmark)

    Bonanos, Nikolaos; Pissis, Polycarpos; Macdonald, J. Ross

    2013-01-01

    Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property, such as admi......Impedance spectroscopy is used for the characterization of materials, such as electroceramics, solid and liquid electrochemical cells, dielectrics and also fully integrated devices, such as fuel cells. It consists of measuring the electrical impedance - or a closely related property......, such as admittance or dielectric constant - as a function of frequency and comparing the results with expectations based on physical, chemical, and microstructural models. This article reviews the principles and practical aspects of the technique, the representations of the results, the analysis of data......, and procedures for the correction of measurement errors. The applications of impedance spectroscopy are illustrated with examples from electroceramics and polymer-based dielectric systems. The way in which the technique is applied to the two classes of materials is compared with reference to the different models...

  7. Automatic detection and segmentation of vascular structures in dermoscopy images using a novel vesselness measure based on pixel redness and tubularness

    Science.gov (United States)

    Kharazmi, Pegah; Lui, Harvey; Stoecker, William V.; Lee, Tim

    2015-03-01

    Vascular structures are one of the most important features in the diagnosis and assessment of skin disorders. The presence and clinical appearance of vascular structures in skin lesions is a discriminating factor among different skin diseases. In this paper, we address the problem of segmentation of vascular patterns in dermoscopy images. Our proposed method is composed of three parts. First, based on biological properties of human skin, we decompose the skin to melanin and hemoglobin component using independent component analysis of skin color images. The relative quantities and pure color densities of each component were then estimated. Subsequently, we obtain three reference vectors of the mean RGB values for normal skin, pigmented skin and blood vessels from the hemoglobin component by averaging over 100000 pixels of each group outlined by an expert. Based on the Euclidean distance thresholding, we generate a mask image that extracts the red regions of the skin. Finally, Frangi measure was applied to the extracted red areas to segment the tubular structures. Finally, Otsu's thresholding was applied to segment the vascular structures and get a binary vessel mask image. The algorithm was implemented on a set of 50 dermoscopy images. In order to evaluate the performance of our method, we have artificially extended some of the existing vessels in our dermoscopy data set and evaluated the performance of the algorithm to segment the newly added vessel pixels. A sensitivity of 95% and specificity of 87% were achieved.

  8. Study of Body Composition by Impedance Analysis

    Science.gov (United States)

    González-Solís, J. L.; Vargas-Luna, M.; Sosa-Aquino, M.; Bernal-Alvarado, J.; Gutiérrez-Juárez, G.; Huerta-Franco, R.; Sanchis-Sabater, A.

    2002-08-01

    This work presents a set of impedance measurements and preliminary results on the analysis of body composition using impedance spectroscopy. This study is made using a pork meat sample and spectra from fat and flesh region were independently obtained using the same electrodes array. From these measurements, and theoretical considerations, it is possible to explain the behavior of the composite sample flesh-fat-flesh and, fitting the electrical parameters of the model, it shows the plausibility of a physical and quantitative application to human corporal composition.

  9. Observations involving broadband impedance modelling

    Energy Technology Data Exchange (ETDEWEB)

    Berg, J S [Stanford Linear Accelerator Center, Menlo Park, CA (United States)

    1996-08-01

    Results for single- and multi-bunch instabilities can be significantly affected by the precise model that is used for the broadband impedance. This paper discusses three aspects of broadband impedance modelling. The first is an observation of the effect that a seemingly minor change in an impedance model has on the single-bunch mode coupling threshold. The second is a successful attempt to construct a model for the high-frequency tails of an r.f. cavity. The last is a discussion of requirements for the mathematical form of an impedance which follow from the general properties of impedances. (author)

  10. ESRD QIP - Vascular Access - Payment Year 2018

    Data.gov (United States)

    U.S. Department of Health & Human Services — This dataset includes facility details, performance rates, vascular access topic measure score, and the state and national average measure scores for the vascular...

  11. Damage Detection Based on Power Dissipation Measured with PZT Sensors through the Combination of Electro-Mechanical Impedances and Guided Waves.

    Science.gov (United States)

    Sevillano, Enrique; Sun, Rui; Perera, Ricardo

    2016-05-05

    The use of piezoelectric ceramic transducers (such as Lead-Zirconate-Titanate-PZT) has become more and more widespread for Structural Health Monitoring (SHM) applications. Among all the techniques that are based on this smart sensing solution, guided waves and electro-mechanical impedance techniques have found wider acceptance, and so more studies and experimental works can be found containing these applications. However, even though these two techniques can be considered as complementary to each other, little work can be found focused on the combination of them in order to define a new and integrated damage detection procedure. In this work, this combination of techniques has been studied by proposing a new integrated damage indicator based on Electro-Mechanical Power Dissipation (EMPD). The applicability of this proposed technique has been tested through different experimental tests, with both lab-scale and real-scale structures.

  12. LIA longitudinal coupling impedance

    International Nuclear Information System (INIS)

    Faltens, A.

    1980-01-01

    The beam generated fields enter into the problems of waveform generation and longitudinal stability. In the former, provision must be made for the longitudinally defocusing forces due to the space charge and the beam loading effects on the accelerating voltage due to the current of a presumably known bunch. In the latter, the concern is for the growth of unintentional perturbations to unacceptably large values through the interaction of the charge and current fluctuations with the rest of the beam and the surrounding structures. These beam generated electric fields may be related to the beam current through a coupling impedance

  13. Impedance of porous IT-SOFC LSCF:CGO composite cathodes

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Jacobsen, Torben; Wandel, Marie

    2011-01-01

    The impedance of technological relevant LSCF:CGO composite IT-SOFC cathodes was studied over a very wide performance range. This was experimentally achieved by impedance measurements on symmetrical cells with three different microstructures in the temperature range 550–850 °C. In order to account...... for the impedance spectra of the poor performing cathodes the Finite-Length-Gerischer (FLG) impedance was derived and applied to the impedance data. The FLG impedance describes for a given microstructure the situation where the cathode is made too thin from a cathode development point of view. The moderate...... performing cathodes showed a slightly suppressed Gerischer impedance, while the impedance spectra of the well performing cathodes showed the presence of an arc due to oxygen gas diffusion. The overall impedance of the well performing cathodes could be described with a slightly suppressed Gerischer impedance...

  14. Electrical impedance tomography

    Science.gov (United States)

    Lobo, Beatriz; Hermosa, Cecilia; Abella, Ana

    2018-01-01

    Continuous assessment of respiratory status is one of the cornerstones of modern intensive care unit (ICU) monitoring systems. Electrical impedance tomography (EIT), although with some constraints, may play the lead as a new diagnostic and guiding tool for an adequate optimization of mechanical ventilation in critically ill patients. EIT may assist in defining mechanical ventilation settings, assess distribution of tidal volume and of end-expiratory lung volume (EELV) and contribute to titrate positive end-expiratory pressure (PEEP)/tidal volume combinations. It may also quantify gains (recruitment) and losses (overdistention or derecruitment), granting a more realistic evaluation of different ventilator modes or recruitment maneuvers, and helping in the identification of responders and non-responders to such maneuvers. Moreover, EIT also contributes to the management of life-threatening lung diseases such as pneumothorax, and aids in guiding fluid management in the critical care setting. Lastly, assessment of cardiac function and lung perfusion through electrical impedance is on the way. PMID:29430443

  15. Broadband impedance of the NESTOR storage ring

    International Nuclear Information System (INIS)

    Androsov, V.P.; Gladkikh, P.I.; Gvozd, A.M.; Karnaukhov, I.M.; Telegin, Yu.N.

    2011-01-01

    The contributions from lossy and inductive vacuum chamber components to the broadband impedance of the NESTOR storage ring are obtained by using both low-frequency analytical approaches and computer simulations. As was expected considering the small ring circumference (15.44m), the main contributions both to the longitudinal impedance Z || /n and the loss factor k loss come from the RF-cavity. Cavity impedance was also estimated with CST Microwave Studio (CST Studio Suite TM 2006) by simulating coaxial wire method commonly used for impedance measurements. Both estimates agree well. Finally, we performed the simulations of a number of inductive elements with CST Particle Studio 2010 by using wake field solver. We have also evaluated the bunch length in NESTOR taking the conservative estimate of 3 Ohm for the ring broadband impedance and have found that the bunch length s z = 0.5 cm could be obtained in steady state operation mode for the designed bunch current of 10 mA and RF-voltage of 250 kV.

  16. Evaluation of ring impedance of the Photon Factory storage ring

    International Nuclear Information System (INIS)

    Kiuchi, T.; Izawa, M.; Tokumoto, S.; Hori, Y.; Sakanaka, S.; Kobayashi, M.; Kobayakawa, H.

    1992-05-01

    The loss parameters of the ducts in the Photon Factory (PF) storage ring were evaluated using the wire method and the code TBCI. Both the measurement and the calculation were done for a different bunch length (σ) ranging from 23 to 80 ps. The PF ring impedance was estimated to be |Z/n|=3.2 Ω using the broadband impedance model. The major contribution to the impedance comes from the bellows and the gate valve sections. Improvements of these components will lower the ring impedance by half. (author)

  17. Using impedance cardiography to detect asymptomatic cardiovascular disease in prehypertensive adults with risk factors.

    Science.gov (United States)

    DeMarzo, Arthur P

    2013-06-01

    Early detection of cardiovascular disease (CVD) in prehypertension could initiate appropriate treatment and prevent progression. Impedance cardiography (ICG) is a noninvasive technology that can be used to assess cardiovascular function. This study used ICG waveform analysis with postural change to detect CVD in asymptomatic prehypertensive adults over 40 years of age with no history of CVD and at least 2 cardiovascular risk factors: cigarette smoking, poor diet, physical inactivity, central obesity, family history of premature CVD, elevated blood glucose, and dyslipidemia. A study group of 25 apparently healthy adults was tested by ICG in standing and supine positions. Criteria for an age-matched control group of 16 healthy subjects included an active lifestyle, no risk factor, and no history of CVD. In addition to hemodynamic measurements of systemic vascular resistance (SVR) and cardiac index (CI), ICG used SVR to assess vascular resistive load, an index of arterial compliance and a widening of the systolic waveform to assess vascular pulsatile load, and waveform analysis and measured wave amplitude to detect ventricular dysfunction. All subjects in the study group had some abnormal ICG data, with an average of 2.9 ± 1.5 abnormalities per person. ICG indicated that 24 (96%) had elevated vascular load, 13 (52%) had some type of ventricular dysfunction, and 12 (48%) had abnormal hemodynamics. For the control group, ICG showed none (0%) with elevated vascular load, none (0%) with ventricular dysfunction, and 7 (44%) with high CI. Prehypertensives over 40 years of age with multiple risk factors have different cardiovascular abnormalities. This ICG test could be used as part of a prevention program for early detection of CVD. An abnormal ICG test could expedite the initiation of customized treatment that targets the subclinical CVD.

  18. Determination of beam coupling impedance in the frequency domain

    Energy Technology Data Exchange (ETDEWEB)

    Niedermayer, Uwe

    2016-07-01

    simulations always contain simplifications, therefore they have to be confirmed by dedicated measurements. However, the beam coupling impedance of a single accelerator component cannot be measured directly. Therefore, a dedicated RF-laboratory was established at GSI, in order to measure broadband beam coupling impedances on the bench by means of the wire method, i.e. without beam. A detailed analysis of measurement methods is given by comparison of analytical, numerical, and measurement results for simplified accelerator devices. One conclusion is, that also the bench measurements have to be validated by dedicated electromagnetic simulations. The thesis closes with selected impedance induced effects on the beam revolving in the synchrotron and relevant impedance results for the future SIS-100 synchrotron for the FAIR project at GSI.

  19. On Impedance Spectroscopy of Supercapacitors

    Science.gov (United States)

    Uchaikin, V. V.; Sibatov, R. T.; Ambrozevich, A. S.

    2016-10-01

    Supercapacitors are often characterized by responses measured by methods of impedance spectroscopy. In the frequency domain these responses have the form of power-law functions or their linear combinations. The inverse Fourier transform leads to relaxation equations with integro-differential operators of fractional order under assumption that the frequency response is independent of the working voltage. To compare long-term relaxation kinetics predicted by these equations with the observed one, charging-discharging of supercapacitors (with nominal capacitances of 0.22, 0.47, and 1.0 F) have been studied by means of registration of the current response to a step voltage signal. It is established that the reaction of devices under study to variations of the charging regime disagrees with the model of a homogeneous linear response. It is demonstrated that relaxation is well described by a fractional stretched exponent.

  20. VASCULAR SURGERY

    African Journals Online (AJOL)

    2016-06-02

    Jun 2, 2016 ... with the literature from South Africa over the last four decades, and reflects the high rate of interpersonal violence in the country.14,15 As expected, cervical ... via the intact circle of Willis in young patients is the most likely explanation for the lack of strokes. Five patients were referred to the Durban vascular ...

  1. Vascular Disorders

    Science.gov (United States)

    ... All Topics A-Z Videos Infographics Symptom Picker Anatomy Bones Joints Muscles Nerves Vessels Tendons About Hand Surgery What is a Hand Surgeon? What is a Hand Therapist? Media Find a Hand Surgeon Home Anatomy Vascular Disorders Email to a friend * required fields ...

  2. Study of Electrical Transport Properties of Thin Films Used as HTL and as Active Layer in Organic Solar Cells, through Impedance Spectroscopy Measurements

    Directory of Open Access Journals (Sweden)

    Camilo A. Otalora

    2016-01-01

    Full Text Available Impedance spectroscopy (IS is used for studying the electrical transport properties of thin films used in organic solar cells with structure ITO/HTL/active layer/cathode, where PEDOT:PSS (poly(3,4-ethylenedioxythiophene:polystyrene sulfonic acid and CuPC (tetrasulfonated copper-phthalocyanine were investigated as HTL (hole transport layer and P3HT:PCBM (poly-3-hexylthiophene:phenyl-C61-butyric acid methyl ester blends prepared from mesitylene and chlorobenzene based solutions were studied as active layer and Ag and Al were used as cathode. The study allowed determining the influence of the type of solvent used for the preparation of the active layer as well as the speed at which the solvents are removed on the carriers mobility. The effect of exposing the layer of P3HT to the air on its mobility was also studied. It was established that samples of P3HT and P3HT:PCBM prepared using mesitylene as a solvent have mobility values significantly higher than those prepared from chlorobenzene which is the solvent most frequently used. It was also determined that the mobility of carriers in P3HT films strongly decreases when this sample is exposed to air. In addition, it was found that the electrical properties of P3HT:PCBM thin films can be improved by removing the solvent slowly which is achieved by increasing the pressure inside the system of spin-coating during the film growth.

  3. Investigation of the Effects of Solution Temperature on the Corrosion Behavior of Austenitic Low-Nickel Stainless Steels in Citric Acid using Impedance and Polarization Measurements

    Directory of Open Access Journals (Sweden)

    Mulimbayan Francis M.

    2015-01-01

    Full Text Available Stainless steels may be classified according to alloy microstructure – ferritic, austenitic, martensitic, duplex, and precipitation hardening grades. Among these, austenitic grade has the largest contribution to market due to the alloy’s numerous industrial and domestic applications. In this study, the corrosion behavior of low-Nickel stainless steel in citric acid was investigated using potentiodynamic polarization techniques and Electrochemical Impedance Spectroscopy (EIS. The corrosion current density which is directly related to corrosion rate was extracted from the generated anodic polarization curve. Increasing the temperature of the citric acid resulted to increased corrosion current densities indicating higher corrosion rates at initial corrosion condition. EIS was performed to generate Nyquist plots whose shape and size depicts the corrosion mechanism and corrosion resistance of the alloy in citric acid, respectively. All the generated Nyquist plots have depressed semi-circle shapes implying that corrosion process takes place with charge-transfer as the rate-determining step. Based from the extracted values of polarization resistance (Rp, the temperature of the solution has negative correlation with the corrosion resistance of the studied alloy.

  4. Impedance deduction for vegetated roof surfaces : multiple geometry strategy

    NARCIS (Netherlands)

    Liu, C.; Hornikx, M.

    2016-01-01

    The transfer function method is an efficient procedure to deduce the ground surface impedance from short-range propagation measurements using one point source. It is able to provide a reasonable prediction of the surface impedance of a vegetated roof as well, and the characteristics of the vegetated

  5. Measuring vascular reactivity with resting-state blood oxygenation level-dependent (BOLD) signal fluctuations: A potential alternative to the breath-holding challenge?

    Science.gov (United States)

    Jahanian, Hesamoddin; Christen, Thomas; Moseley, Michael E; Pajewski, Nicholas M; Wright, Clinton B; Tamura, Manjula K; Zaharchuk, Greg

    2017-07-01

    Measurement of the ability of blood vessels to dilate and constrict, known as vascular reactivity, is often performed with breath-holding tasks that transiently raise arterial blood carbon dioxide (P a CO 2 ) levels. However, following the proper commands for a breath-holding experiment may be difficult or impossible for many patients. In this study, we evaluated two approaches for obtaining vascular reactivity information using blood oxygenation level-dependent signal fluctuations obtained from resting-state functional magnetic resonance imaging data: physiological fluctuation regression and coefficient of variation of the resting-state functional magnetic resonance imaging signal. We studied a cohort of 28 older adults (69 ± 7 years) and found that six of them (21%) could not perform the breath-holding protocol, based on an objective comparison with an idealized respiratory waveform. In the subjects that could comply, we found a strong linear correlation between data extracted from spontaneous resting-state functional magnetic resonance imaging signal fluctuations and the blood oxygenation level-dependent percentage signal change during breath-holding challenge ( R 2  = 0.57 and 0.61 for resting-state physiological fluctuation regression and resting-state coefficient of variation methods, respectively). This technique may eliminate the need for subject cooperation, thus allowing the evaluation of vascular reactivity in a wider range of clinical and research conditions in which it may otherwise be impractical.

  6. A Batteryless Sensor ASIC for Implantable Bio-Impedance Applications.

    Science.gov (United States)

    Rodriguez, Saul; Ollmar, Stig; Waqar, Muhammad; Rusu, Ana

    2016-06-01

    The measurement of the biological tissue's electrical impedance is an active research field that has attracted a lot of attention during the last decades. Bio-impedances are closely related to a large variety of physiological conditions; therefore, they are useful for diagnosis and monitoring in many medical applications. Measuring living tissues, however, is a challenging task that poses countless technical and practical problems, in particular if the tissues need to be measured under the skin. This paper presents a bio-impedance sensor ASIC targeting a battery-free, miniature size, implantable device, which performs accurate 4-point complex impedance extraction in the frequency range from 2 kHz to 2 MHz. The ASIC is fabricated in 150 nm CMOS, has a size of 1.22 mm × 1.22 mm and consumes 165 μA from a 1.8 V power supply. The ASIC is embedded in a prototype which communicates with, and is powered by an external reader device through inductive coupling. The prototype is validated by measuring the impedances of different combinations of discrete components, measuring the electrochemical impedance of physiological solution, and performing ex vivo measurements on animal organs. The proposed ASIC is able to extract complex impedances with around 1 Ω resolution; therefore enabling accurate wireless tissue measurements.

  7. Inter-Eye Agreement in Measurement of Retinal Vascular Fractal Dimension in Patients with Type 1 Diabetes Mellitus

    DEFF Research Database (Denmark)

    Pedersen, Knud B; Broe, Rebecca; Grauslund, Jakob

    2016-01-01

    PURPOSE: To investigate inter-eye agreement in retinal vascular fractal dimension (FD) in patients with type 1 diabetes. METHODS: In a cross-sectional study, both eyes were exained in 178 patients with type 1 diabetes. All vessels in a zone 0.5-2.0 disc diameters from the optic disc were traced...... and FD calculated with the box-counting method using SIVA-Fractal semiautomatic software. The modified Early Treatment Diabetic Retinopathy Study (ETDRS) scale was used to grade diabetic retinopathy (DR). Pitman's test of difference in variance was used to calculated inter-eye agreement in FD according...

  8. Idiopathic pulmonary fibrosis is associated with increased impedance measures of reflux compared to non-fibrotic disease among pre-lung transplant patients.

    Science.gov (United States)

    Gavini, S; Finn, R T; Lo, W-K; Goldberg, H J; Burakoff, R; Feldman, N; Chan, W W

    2015-09-01

    Gastroesophageal reflux (GER) has been associated with idiopathic pulmonary fibrosis (IPF), although the mechanism remains unclear. Gastroesophageal reflux/microaspiration may lead to lung fibrosis, while increased pulmonary workload may also worsen GER. Comparing the GER profile of IPF patients to chronic obstructive pulmonary disease (COPD) patients with similar lung function may help delineate the role of GER in IPF pathogenesis. This was a retrospective cohort study of IPF and COPD patients undergoing pre-lung transplant multichannel intraluminal impedance and pH study (MII-pH) off acid suppression at a tertiary center in 2008-2014. Patients with prior fundoplication were excluded. Baseline demographics, pulmonary function test, and MII-pH results were recorded. Univariate analyses were performed using Fisher's exact (binary variables) and Student's t (continuous variables) tests. Logistic regression was performed to adjust for potential confounders. A total of 90 subjects (54 IPF, 36 COPD) met inclusion criteria. Compared to COPD, IPF patients had increased total reflux episodes (65.9 vs 46.1, p = 0.02), proximal reflux episodes (30.3 vs 20.3, p = 0.04), and prevalence of abnormal total reflux episodes (38.9% vs 16.7%, p = 0.02). On multivariate analyses, abnormal total reflux episodes (OR: 4.9, p = 0.05) and bolus reflux exposure time (OR: 4, p = 0.04) remained significantly associated with IPF. Abnormal reflux was significantly more prevalent among IPF patients after controlling for lung disease severity. Gastroesophageal reflux/microaspiration likely plays a role in fibrosis in IPF. A significant portion of IPF patients had increased non-acid reflux. Therapies aiming to prevent reflux of gastric contents may be more beneficial than antisecretory medications alone in these patients. © 2015 John Wiley & Sons Ltd.

  9. Laparoscopic Nissen fundoplication mainly reduces the volume of acid reflux and potentially improves mucosal integrity up to the middle esophagus in neurologically impaired children detected by esophageal combined pH-multichannel intraluminal impedance measurements.

    Science.gov (United States)

    Fukahori, Suguru; Yagi, Minoru; Ishii, Shinji; Asagiri, Kimio; Saikusa, Nobuyuki; Hashizume, Naoki; Yoshida, Motomu; Masui, Daisuke; Sakamoto, Saki; Tsuruhisa, Shihori; Kurahachi, Tomohiro; Tanaka, Yoshiaki

    2016-08-01

    The aim of this study was to evaluate detailed changes of gastroesophageal reflux disease (GERD) in children before and after laparoscopic Nissen fundoplication (LNF) utilizing esophageal combined pH-multichannel intraluminal impedance (pH/MII) measurements. Thirteen patients with neurological impairment, who received laparoscopic Nissen fundoplication (LNF) owing to refractory pathological GERD, were enrolled in this study. 24h pH/MII was conducted in all patients before and one year after LNF. Each parameter of the pH/MII was evaluated and compared each other. Both the mean pH index and bolus exposure index after LNF were significantly lower than those before LNF. The mean numbers of total and nonacid reflux episodes after LNF were significantly lower than those before LNF. The mean numbers of total, acid and nonacid proximal reflux episodes after LNF were significantly lower than those before LNF. The mean baseline impedance values from Z3 to Z6 after LNF were significantly higher than those before LNF. The present study provides new insights into the effects of LNF in pediatric patients, which prevents mainly acid reflux episodes from rising to the proximal esophagus, and is expected to improve the mucosal integrity up to the middle esophagus. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Measurement of the perfusion fraction in brain tumors with intravoxel incoherent motion MR imaging: validation with histopathological vascular density in meningiomas.

    Science.gov (United States)

    Togao, Osamu; Hiwatashi, Akio; Yamashita, Koji; Kikuchi, Kazufumi; Momosaka, Daichi; Yoshimoto, Koji; Kuga, Daisuke; Mizoguchi, Masahiro; Suzuki, Satoshi O; Iwaki, Toru; Van Cauteren, Marc; Iihara, Koji; Honda, Hiroshi

    2018-05-01

    To evaluate the quantification performance of the perfusion fraction (f) measured with intravoxel incoherent motion (IVIM) MR imaging in a comparison with the histological vascular density in meningiomas. 29 consecutive patients with meningioma (59.0 ± 16.8 years old, 8 males and 21 females) who underwent a subsequent surgical resection were examined with both IVIM imaging and a histopathological analysis. IVIM imaging was conducted using a single-shot SE-EPI sequence with 13 b-factors (0, 10, 20, 30, 50, 80, 100, 200, 300, 400, 600, 800, 1000 s mm - 2 ) at 3T. The perfusion fraction (f) was calculated by fitting the IVIM bi-exponential model. The 90-percentile f-value in the tumor region-of-interest (ROI) was defined as the maximum f-value (f-max). Histopathological vascular density (%Vessel) was measured on CD31-immunostainted histopathological specimens. The correlation and agreement between the f-values and %Vessel was assessed. The f-max (15.5 ± 5.5%) showed excellent agreement [intraclass correlation coefficient (ICC) = 0.754] and a significant correlation (r = 0.69, p < 0.0001) with the %Vessel (12.9 ± 9.4%) of the tumors. The Bland-Altman plot analysis showed excellent agreement between the f-max and %Vessel (bias, -2.6%; 95% limits of agreement, from -16.0 to 10.8%). The f-max was not significantly different among the histological subtypes of meningioma. An excellent agreement and a significant correlation were observed between the f-values and %Vessel. The f-value can be used as a noninvasive quantitative imaging measure to directly assess the vascular volume fraction in brain tumors. Advances in knowledge: The f-value measured by IVIM imaging showed a significant correlation and an excellent agreement with the histological vascular density in the meningiomas. The f-value can be used as a noninvasive and quantitative imaging measure to directly assess the volume fraction of capillaries in brain tumors.

  11. Impedance analysis on organic ultrathin layers

    Energy Technology Data Exchange (ETDEWEB)

    Bom, Sidhant; Wagner, Veit [Jacobs University Bremen, School of Engineering and Science, Campus Ring 8, 28759 Bremen (Germany)

    2008-07-01

    Impedance spectroscopy is a standard technique for thin film analysis to obtain important information as thicknesses, diffusion properties of mobile ions and leakage currents. The measured electrical impedance of a sample is modeled by a physical equivalent circuit of resistors and capacitors. In the present work this information is obtained as a function of frequency also for ultrathin organic layers in the monolayer regime. A series of semiconducting and insulating polymers (regioregular poly-3-hexylthiophene (rr-P3HT), polymethylmethacrylate (PMMA)) and self assembled monolayers (octadecyltrichlorosilane (OTS), hexamethyldisilazane (HMDS), thiolated phospholipids) were deposited either on highly n-doped silicon wafers or on gold surfaces. E.g. ultrathin layers were obtained by dip coating a silicon wafer in rr-P3HT solution in chloroform. The thickness of 2 nm determined for this system by impedance measurement agrees well with the atomic force microscopy analysis and corresponds to a single layer of polymer chains. The leakage current is seen as an ohmic contribution at low frequencies and allows a systematic optimization of process parameters. In summary, impedance spectroscopy allows very fast and convenient analysis of thin organic layers even down to the monolayer regime.

  12. Electrical impedance spectroscopy and diagnosis of tendinitis

    International Nuclear Information System (INIS)

    Yoon, Kisung; Lee, Kyeong Woo; Kim, Sang Beom; Lee, Jong Hwa; Han, Tai Ryoon; Jung, Dong Keun; Roh, Mee Sook

    2010-01-01

    There have been a number of studies that investigate the usefulness of bioelectric signals in diagnoses and treatment in the medical field. Tendinitis is a musculoskeletal disorder with a very high rate of occurrence. This study attempts to examine whether electrical impedance spectroscopy (EIS) can detect pathological changes in a tendon and find the exact location of the lesion. Experimental tendinitis was induced by injecting collagenase into one side of the patellar tendons in rabbits, while the other side was used as the control. After measuring the impedance in the tendinitis and intact tendon tissue, the dissipation factor was computed. The real component of impedance and the dissipation factor turned out to be lower in tendinitis than in intact tissues. Moreover, the tendinitis dissipation factor spectrum showed a clear difference from that of the intact tendon, indicating its usefulness as a tool for detecting the location of the lesion. Pathologic findings from the tissues that were obtained after measuring the impedance confirmed the presence of characteristics of tendinitis. In conclusion, EIS is a useful method for diagnosing tendinitis and detecting the lesion location in invasive treatment

  13. Advanced impedance modeling of solid oxide electrochemical cells

    DEFF Research Database (Denmark)

    Graves, Christopher R.; Hjelm, Johan

    2014-01-01

    Impedance spectroscopy is a powerful technique for detailed study of the electrochemical and transport processes that take place in fuel cells and electrolysis cells, including solid oxide cells (SOCs). Meaningful analysis of impedance measurements is nontrivial, however, because a large number...... techniques to provide good guesses for the modeling parameters, like transforming the impedance data to the distribution of relaxation times (DRT), together with experimental parameter sensitivity studies, is the state-of-the-art approach to achieve good EC model fits. Here we present new impedance modeling...... electrode and 2-D gas transport models which have fewer unknown parameters for the same number of processes, (ii) use of a new model fitting algorithm, “multi-fitting”, in which multiple impedance spectra are fit simultaneously with parameters linked based on the variation of measurement conditions, (iii...

  14. Assessment of chest impedance in relation to phonocardiography

    DEFF Research Database (Denmark)

    Zimmermann, Niels Henrik; Møller, Henrik; Hammershøi, Dorte

    2010-01-01

    the surface of the skin to the transducer. If the impedance of the skin is known, it may be possible to optimize the transducer to achieve an improved signal for a certain frequency range, while attenuating disturbing noise. Further, from a classical stethoscope it is known, that the sound picked up...... by the stethoscope can be influenced by changing the pressure on the chest piece of the stethoscope. A high pressure will stretch the skin similar to a drum skin, and attenuate lower frequencies, while lighter pressure will broaden the frequency range. By using an impedance tube (also known as standing wave tube......), it is possible to measure the impedance of the surface of the skin and at the same time investigate the influence of different pressures and diameters of a transducer. The impedance tube is made specifically with the purpose of measuring chest impedances in the frequency range from 50 Hz to 5 kHz. An MLS...

  15. Usefulness of repeated N-terminal pro-B-type natriuretic peptide measurements as incremental predictor for long-term cardiovascular outcome after vascular surgery.

    Science.gov (United States)

    Goei, Dustin; van Kuijk, Jan-Peter; Flu, Willem-Jan; Hoeks, Sanne E; Chonchol, Michel; Verhagen, Hence J M; Bax, Jeroen J; Poldermans, Don

    2011-02-15

    Plasma N-terminal pro-B-type natriuretic peptide (NT-pro-BNP) levels improve preoperative cardiac risk stratification in vascular surgery patients. However, single preoperative measurements of NT-pro-BNP cannot take into account the hemodynamic stress caused by anesthesia and surgery. Therefore, the aim of the present study was to assess the incremental predictive value of changes in NT-pro-BNP during the perioperative period for long-term cardiac mortality. Detailed cardiac histories, rest left ventricular echocardiography, and NT-pro-BNP levels were obtained in 144 patients before vascular surgery and before discharge. The study end point was the occurrence of cardiovascular death during a median follow-up period of 13 months (interquartile range 5 to 20). Preoperatively, the median NT-pro-BNP level in the study population was 314 pg/ml (interquartile range 136 to 1,351), which increased to a median level of 1,505 pg/ml (interquartile range 404 to 6,453) before discharge. During the follow-up period, 29 patients (20%) died, 27 (93%) from cardiovascular causes. The median difference in NT-pro-BNP in the survivors was 665 pg/ml, compared to 5,336 pg/ml in the patients who died (p = 0.01). Multivariate Cox regression analyses, adjusted for cardiac history and cardiovascular risk factors (age, angina pectoris, myocardial infarction, stroke, diabetes mellitus, renal dysfunction, body mass index, type of surgery and the left ventricular ejection fraction), demonstrated that the difference in NT-pro-BNP level between pre- and postoperative measurement was the strongest independent predictor of cardiac outcome (hazard ratio 3.06, 95% confidence interval 1.36 to 6.91). In conclusion, the change in NT-pro-BNP, indicated by repeated measurements before surgery and before discharge is the strongest predictor of cardiac outcomes in patients who undergo vascular surgery. Copyright © 2011 Elsevier Inc. All rights reserved.

  16. Impedance models in time domain

    NARCIS (Netherlands)

    Rienstra, S.W.

    2005-01-01

    Necessary conditions for an impedance function are derived. Methods available in the literature are discussed. A format with recipe is proposed for an exact impedance condition in time domain on a time grid, based on the Helmholtz resonator model. An explicit solution is given of a pulse reflecting

  17. Impedance Source Power Electronic Converters

    DEFF Research Database (Denmark)

    Liu, Yushan; Abu-Rub, Haitham; Ge, Baoming

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable...... and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key...... features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding...

  18. Impedance source power electronic converters

    CERN Document Server

    Liu, Yushan; Ge, Baoming; Blaabjerg, Frede; Ellabban, Omar; Loh, Poh Chiang

    2016-01-01

    Impedance Source Power Electronic Converters brings together state of the art knowledge and cutting edge techniques in various stages of research related to the ever more popular impedance source converters/inverters. Significant research efforts are underway to develop commercially viable and technically feasible, efficient and reliable power converters for renewable energy, electric transportation and for various industrial applications. This book provides a detailed understanding of the concepts, designs, controls, and application demonstrations of the impedance source converters/inverters. Key features: Comprehensive analysis of the impedance source converter/inverter topologies, including typical topologies and derived topologies. Fully explains the design and control techniques of impedance source converters/inverters, including hardware design and control parameter design for corresponding control methods. Presents the latest power conversion solutions that aim to advance the role of pow...

  19. Geometric beam coupling impedance of LHC secondary collimators

    Science.gov (United States)

    Frasciello, Oscar; Tomassini, Sandro; Zobov, Mikhail; Salvant, Benoit; Grudiev, Alexej; Mounet, Nicolas

    2016-02-01

    The High Luminosity LHC project is aimed at increasing the LHC luminosity by an order of magnitude. One of the key ingredients to achieve the luminosity goal is the beam intensity increase. In order to keep beam instabilities under control and to avoid excessive power losses a careful design of new vacuum chamber components and an improvement of the present LHC impedance model are required. Collimators are among the major impedance contributors. Measurements with beam have revealed that the betatron coherent tune shifts were higher by about a factor of 2 with respect to the theoretical predictions based on the LHC impedance model up to 2012. In that model the resistive wall impedance has been considered as the dominating impedance contribution for collimators. By carefully simulating also their geometric impedance we have contributed to the update of the LHC impedance model, reaching also a better agreement between the measured and simulated betatron tune shifts. During the just ended LHC Long Shutdown I (LSI), TCS/TCT collimators were replaced by new devices embedding BPMs and TT2-111R ferrite blocks. We present here preliminary estimations of their broad-band impedance, showing that an increase of about 20% is expected in the kick factors with respect to previous collimators without BPMs.

  20. Heart-rate sensitive optical coherence angiography for measuring vascular changes due to posttraumatic brain injury in mice

    Science.gov (United States)

    Tremoleda, Jordi L.; Alvarez, Karl; Aden, Abdirahman; Donnan, Robert; Michael-Titus, Adina T.; Tomlins, Peter H.

    2017-12-01

    Traumatic brain injury (TBI) results in direct vascular disruption, triggering edema, and reduction in cerebral blood flow. Therefore, understanding the pathophysiology of brain microcirculation following TBI is important for the development of effective therapies. Optical coherence angiography (OCA) is a promising tool for evaluating TBI in rodent models. We develop an approach to OCA that uses the heart-rate frequency to discriminate between static tissue and vasculature. This method operates on intensity data and is therefore not phase sensitive. Furthermore, it does not require spatial overlap of voxels and thus can be applied to pre-existing datasets for which oversampling may not have been explicitly considered. Heart-rate sensitive OCA was developed for dynamic assessment of mouse microvasculature post-TBI. Results show changes occurring at 5-min intervals within the first 50 min of injury.

  1. Bioelectrical impedance analysis of bovine milk fat

    Science.gov (United States)

    Veiga, E. A.; Bertemes-Filho, P.

    2012-12-01

    Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  2. Bioelectrical impedance analysis of bovine milk fat

    Energy Technology Data Exchange (ETDEWEB)

    Veiga, E A; Bertemes-Filho, P [Department of Electrical Eng., State University of Santa Catarina, Joinville (Brazil)

    2012-12-20

    Three samples of 250ml at home temperature of 20 Degree-Sign C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  3. Bioelectrical impedance analysis of bovine milk fat

    International Nuclear Information System (INIS)

    Veiga, E A; Bertemes-Filho, P

    2012-01-01

    Three samples of 250ml at home temperature of 20°C were obtained from whole, low fat and fat free bovine UHT milk. They were analysed by measuring both impedance spectra and dc conductivity in order to establish the relationship between samples related to fat content. An impedance measuring system was developed, which is based on digital oscilloscope, a current source and a FPGA. Data was measured by the oscilloscope in the frequency 1 kHz to 100 kHz. It was showed that there is approximately 7.9% difference in the conductivity between whole and low fat milk whereas 15.9% between low fat and free fat one. The change of fatness in the milk can be significantly sensed by both impedance spectra measurements and dc conductivity. This result might be useful for detecting fat content of milk in a very simple way and also may help the development of sensors for measuring milk quality, as for example the detection of mastitis.

  4. Differences in Blood Pressure and Vascular Responses Associated with Ambient Fine Particulate Matter Exposures Measured at the Personal Versus Community Level

    Science.gov (United States)

    Background Higher ambient fine particulate matter (PM2.5) levels can be associated with increased blood pressure and vascular dysfunction. Objectives To determine the differential effects on blood pressure and vascular function of daily changes in community ambient-...

  5. Monitoring of the state of the paper machine circulation water with a wide-band impedance measurement; Paperikoneen kiertoveden tilan seuranta laajakaistaisella impedanssimittauksella - MPKT 02

    Energy Technology Data Exchange (ETDEWEB)

    Varpula, T [VTT Automation, Espoo (Finland). Measurement Technology

    1999-12-31

    A new measurement method for monitoring the chemical state of the circulation water in the paper machine is proposed and studied. In the method, the electrical properties - conductivity and permittivity - of the water are measured in a wide frequency band: 20 Hz - 10 mhz. Large-molecule organic compounds in the water are expected cause characteristic changes in the dielectric properties of the water. Continuous monitoring of the permittivity in the wide frequency band thus reveals their presence. Various electronic measurement setups for the measurement are constructed and studied by using test samples. If the method turns out to be promising, a prototype device will be made. (orig.)

  6. Monitoring of the state of the paper machine circulation water with a wide-band impedance measurement; Paperikoneen kiertoveden tilan seuranta laajakaistaisella impedanssimittauksella - MPKT 02

    Energy Technology Data Exchange (ETDEWEB)

    Varpula, T. [VTT Automation, Espoo (Finland). Measurement Technology

    1998-12-31

    A new measurement method for monitoring the chemical state of the circulation water in the paper machine is proposed and studied. In the method, the electrical properties - conductivity and permittivity - of the water are measured in a wide frequency band: 20 Hz - 10 mhz. Large-molecule organic compounds in the water are expected cause characteristic changes in the dielectric properties of the water. Continuous monitoring of the permittivity in the wide frequency band thus reveals their presence. Various electronic measurement setups for the measurement are constructed and studied by using test samples. If the method turns out to be promising, a prototype device will be made. (orig.)

  7. Mechanical impedance of the human body in vertical direction.

    Science.gov (United States)

    Holmlund, P; Lundström, R; Lindberg, L

    2000-08-01

    The mechanical impedance of the human body in sitting posture and vertical direction was measured during different experimental conditions, such as vibration level (0.5-1.4 m/s2), frequency (2-100 Hz), body weight (57-92 kg), relaxed and erect upper body posture. The outcome shows that impedance increases with frequency up to a peak at about 5 Hz after which it decreases in a complex manner which includes two additional peaks. The frequency at which the first and second impedance peak occurs decreases with higher vibration level. Erect, compared with relaxed body posture resulted in higher impedance magnitudes and with peaks located at somewhat higher frequencies. Heavy persons show higher impedance magnitudes and peaks at lower frequencies.

  8. Hybrid-Source Impedance Networks

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    Hybrid-source impedance networks have attracted attention among researchers because of their flexibility in performing buck-boost energy conversion. To date, three distinct types of impedance networks can be summarized for implementing voltage-type inverters with another three types summarized...... for current-type inverters. These impedance networks can in principle be combined into two generic network entities, before multiple of them can further be connected together by applying any of the two proposed generalized cascading concepts. The resulting two-level and three-level inverters implemented using...

  9. Vascular ultrasound.

    Science.gov (United States)

    Pilcher, D B; Ricci, M A

    1998-04-01

    Surgeon-interpreted diagnostic ultrasound has become the preferred screening test and often the definitive test for the diagnosis of arterial stenosis, aneurysm, and venous thrombosis. As a modality for surveillance, its noninvasive quality makes it particularly appealing as the test of choice to screen patients for abdominal aortic aneurysms or to perform follow-up examinations on those patients with a carotid endartectomy or in situ bypass grafts. The increasing reliance on intraoperative duplex imaging of vascular procedures demands that the surgeon learn the skills to perform the studies without a technologist or radiologist to interpret the examination.

  10. Development on electromagnetic impedance function modeling and its estimation

    Energy Technology Data Exchange (ETDEWEB)

    Sutarno, D., E-mail: Sutarno@fi.itb.ac.id [Earth Physics and Complex System Division Faculty of Mathematics and Natural Sciences Institut Teknologi Bandung (Indonesia)

    2015-09-30

    Today the Electromagnetic methods such as magnetotellurics (MT) and controlled sources audio MT (CSAMT) is used in a broad variety of applications. Its usefulness in poor seismic areas and its negligible environmental impact are integral parts of effective exploration at minimum cost. As exploration was forced into more difficult areas, the importance of MT and CSAMT, in conjunction with other techniques, has tended to grow continuously. However, there are obviously important and difficult problems remaining to be solved concerning our ability to collect process and interpret MT as well as CSAMT in complex 3D structural environments. This talk aim at reviewing and discussing the recent development on MT as well as CSAMT impedance functions modeling, and also some improvements on estimation procedures for the corresponding impedance functions. In MT impedance modeling, research efforts focus on developing numerical method for computing the impedance functions of three dimensionally (3-D) earth resistivity models. On that reason, 3-D finite elements numerical modeling for the impedances is developed based on edge element method. Whereas, in the CSAMT case, the efforts were focused to accomplish the non-plane wave problem in the corresponding impedance functions. Concerning estimation of MT and CSAMT impedance functions, researches were focused on improving quality of the estimates. On that objective, non-linear regression approach based on the robust M-estimators and the Hilbert transform operating on the causal transfer functions, were used to dealing with outliers (abnormal data) which are frequently superimposed on a normal ambient MT as well as CSAMT noise fields. As validated, the proposed MT impedance modeling method gives acceptable results for standard three dimensional resistivity models. Whilst, the full solution based modeling that accommodate the non-plane wave effect for CSAMT impedances is applied for all measurement zones, including near-, transition

  11. Impedance Analysis of Silicon Nanowire Lithium Ion Battery Anodes

    KAUST Repository

    Ruffo, Riccardo; Hong, Seung Sae; Chan, Candace K.; Huggins, Robert A.; Cui, Yi

    2009-01-01

    The impedance behavior of silicon nanowire electrodes has been investigated to understand the electrochemical process kinetics that influences the performance when used as a high-capacity anode in a lithium ion battery. The ac response was measured

  12. Characterizing aging effects of lithium ion batteries by impedance spectroscopy

    International Nuclear Information System (INIS)

    Troeltzsch, Uwe; Kanoun, Olfa; Traenkler, Hans-Rolf

    2006-01-01

    Impedance spectroscopy is one of the most promising methods for characterizing aging effects of portable secondary batteries online because it provides information about different aging mechanisms. However, application of impedance spectroscopy 'in the field' has some higher requirements than for laboratory experiments. It requires a fast impedance measurement process, an accurate model applicable with several batteries and a robust method for model parameter estimation. In this paper, we present a method measuring impedance at different frequencies simultaneously. We propose to use a composite electrode model, capable to describe porous composite electrode materials. A hybrid method for parameter estimation based on a combination of evolution strategy and Levenberg-Marquardt method allowed a robust and fast parameter calculation. Based on this approach, an experimental investigation of aging effects of a lithium ion battery was carried out. After 230 discharge/charge cycles, the battery showed a 14% decreased capacity. Modeling results show that series resistance, charge transfer resistance and Warburg coefficient changed thereby their values by approximately 60%. A single frequency impedance measurement, usually carried out at 1 kHz, delivers only information about series resistance. Impedance spectroscopy allows additionally the estimation of charge transfer resistance and Warburg coefficient. This fact and the high sensitivity of model parameters to capacity change prove that impedance spectroscopy together with an accurate modeling deliver information that significantly improve characterization of aging effects

  13. Characterizing aging effects of lithium ion batteries by impedance spectroscopy

    Energy Technology Data Exchange (ETDEWEB)

    Troeltzsch, Uwe [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany)]. E-mail: uwe.troeltzsch@unibw-muenchen.de; Kanoun, Olfa [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany); Traenkler, Hans-Rolf [University of the Bundeswehr Munich Institute for Measurement and Automation, 85579 Neubiberg (Germany)

    2006-01-20

    Impedance spectroscopy is one of the most promising methods for characterizing aging effects of portable secondary batteries online because it provides information about different aging mechanisms. However, application of impedance spectroscopy 'in the field' has some higher requirements than for laboratory experiments. It requires a fast impedance measurement process, an accurate model applicable with several batteries and a robust method for model parameter estimation. In this paper, we present a method measuring impedance at different frequencies simultaneously. We propose to use a composite electrode model, capable to describe porous composite electrode materials. A hybrid method for parameter estimation based on a combination of evolution strategy and Levenberg-Marquardt method allowed a robust and fast parameter calculation. Based on this approach, an experimental investigation of aging effects of a lithium ion battery was carried out. After 230 discharge/charge cycles, the battery showed a 14% decreased capacity. Modeling results show that series resistance, charge transfer resistance and Warburg coefficient changed thereby their values by approximately 60%. A single frequency impedance measurement, usually carried out at 1 kHz, delivers only information about series resistance. Impedance spectroscopy allows additionally the estimation of charge transfer resistance and Warburg coefficient. This fact and the high sensitivity of model parameters to capacity change prove that impedance spectroscopy together with an accurate modeling deliver information that significantly improve characterization of aging effects.

  14. Simulation of the LHC injection kicker impedance test bench

    CERN Document Server

    Tsutsui, H

    2003-01-01

    The coupling impedance measurements of the LHC injection kicker test bench are simulated by HFSS code. The simulation gives qualitatively good agreement with the measurement. In order to damp the resonances, some ferrite rings are tested in the simulation. Longitudinal resonances are damped by a ferrite ring of large tan$\\delta_{\\mu}$. The effect of the ferrite ring is small for damping the transverse impedance resonance around 30 MHz.

  15. Instantaneous Respiratory Estimation from Thoracic Impedance by Empirical Mode Decomposition

    OpenAIRE

    Wang, Fu-Tai; Chan, Hsiao-Lung; Wang, Chun-Li; Jian, Hung-Ming; Lin, Sheng-Hsiung

    2015-01-01

    Impedance plethysmography provides a way to measure respiratory activity by sensing the change of thoracic impedance caused by inspiration and expiration. This measurement imposes little pressure on the body and uses the human body as the sensor, thereby reducing the need for adjustments as body position changes and making it suitable for long-term or ambulatory monitoring. The empirical mode decomposition (EMD) can decompose a signal into several intrinsic mode functions (IMFs) that disclos...

  16. A comparison study of electrodes for neonate electrical impedance tomography

    International Nuclear Information System (INIS)

    Rahal, Mohamad; Demosthenous, Andreas; Khor, Joo Moy; Tizzard, Andrew; Bayford, Richard

    2009-01-01

    Electrical impedance tomography (EIT) is an imaging technique that has the potential to be used for studying neonate lung function. The properties of the electrodes are very important in multi-frequency EIT (MFEIT) systems, particularly for neonates, as the skin cannot be abraded to reduce contact impedance. In this work, the impedance of various clinical electrodes as a function of frequency is investigated to identify the optimum electrode type for this application. Six different types of self-adhesive electrodes commonly used in general and neonatal cardiology have been investigated. These electrodes are Ag/AgCl electrodes from the Ambu® Cardiology Blue sensors range (BR, NF and BRS), Kendall (KittyCat(TM) and ARBO®) and Philips 13953D electrodes. In addition, a textile electrode without gel from Textronics was tested on two subjects to allow comparison with the hydrogel-based electrodes. Two- and four-electrode measurements were made to determine the electrode-interface and tissue impedances, respectively. The measurements were made on the back of the forearm of six healthy adult volunteers without skin preparation with 2.5 cm electrode spacing. Impedance measurements were carried out using a Solartron SI 1260 impedance/gain-phase analyser with a frequency range from 10 Hz to 1 MHz. For the electrode-interface impedance, the average magnitude decreased with frequency, with an average value of 5 kΩ at 10 kHz and 337 Ω at 1 MHz; for the tissue impedance, the respective values were 987 Ω and 29 Ω. Overall, the Ambu BRS, Kendall ARBO® and Textronics textile electrodes gave the lowest electrode contact impedance at 1 MHz. Based on the results of the two-electrode measurements, simple RC models for the Ambu BRS and Kendall-ARBO and Textronics textile electrodes have been derived for MFEIT applications

  17. The Quantitative Measurements of Vascular Density and Flow Area of Optic Nerve Head Using Optical Coherence Tomography Angiography.

    Science.gov (United States)

    Bazvand, Fatemeh; Mirshahi, Reza; Fadakar, Kaveh; Faghihi, Houshangh; Sabour, Siamak; Ghassemi, Fariba

    2017-08-01

    The purpose of this study was to evaluate the vascular density (VD) and the flow area on optic nerve head (ONH) and peripapillary area, and the impact of age and sex using optical coherence tomography angiography (OCTA) in healthy human subjects. Both eyes of each volunteer were scanned by an RTVue XR Avanti; Optovue with OCTA using the split-spectrum amplitude-decorrelation angiography algorithm technique. Masked graders evaluated enface angiodisc OCTA data. The flow area of ONH and the VD were automatically calculated. A total of 79 eyes of patients with a mean age of 37.03±11.27 were examined. The total ONH (papillary and peripapillary) area VD was 56.03%±4.55%. The flow area of the ONH was 1.74±0.10 mm/1.34 mm. The temporal and inferotemporal peripapillary VD was different between male and female patients. Increasing age causes some changes in the flow area of the ONH and the papillary VD from the third to the fourth decade (analysis of variance test; P<0.05). A normal quantitative database of the flow area and VD of the papillary and peripapillary area, obtained by RTVue XR with OCT angiography technique, is presented here.

  18. 10 GHz surface impedance measurements of (Y9Er)BaCuO films produced by MOCVD, laser ablation, and sputtering

    International Nuclear Information System (INIS)

    Luine, J.; Daly, K.; Hu, R.; Kain, A.; Lee, A.; Manasevit, H.; Pettiette-Hall, C.; Simon, R.; St John, D.; Wagner, M.

    1991-01-01

    This paper reports on a parallel-plate resonator technique previously used to measure microwave surface resistance R s (T) extended to also measure absolute penetration depth λ(T). Measurements of both quantities near 10 GHz from 4.2 K to Tc are reported for ErBaCuO thin films produced by metal-organic chemical vapor deposition (MOCVD) and YBaCuO think films produced by laser ablation and single-target off-axis sputtering. All the films were made at TRW. Each production method gives rise to films whose surface resistance is below 1 milliohm at temperatures below 40K. The low temperature penetration depths range from 250 nm for the laser ablation and sputtered films to 800 nm for the MOCVD films. The penetration depths in all cases increase with temperature according to the Gorter-Casimir temperature dependence

  19. Impedance Characterisation of the SPS Wire Scanner

    CERN Document Server

    AUTHOR|(CDS)2091911; Prof. Sillanpää, Mika

    As a beam diagnostic tool, the SPS wire scanner interacts with the proton bunches traversing the vacuum pipes of the Super Proton Synchrotron particle accelerator. Following the interaction, the bunches decelerate or experience momentum kicks off-axis and couple energy to the cavity walls, resonances and to the diagnostic tool, the scanning wire. The beam coupling impedance and, in particular, the beam induced heating of the wire motivate the characterisation and redesign of the SPS wire scanner. In this thesis, we characterise RF-wise the low frequency modes of the SPS wire scanner. These have the highest contribution to the impedance. We measure the cavity modes in terms of resonance frequency and quality factor by traditional measurement techniques and data analysis. We carry out a 4-port measurement to evaluate the beam coupling to the scanning wire, that yields the spectral heating power. If combined with the simulations, one is able to extract the beam coupling impedance and deduce the spectral dissipa...

  20. Beam impedance of ferrite kicker magnets

    International Nuclear Information System (INIS)

    Voelker, F.; Lambertson, G.

    1989-03-01

    We have measured the longitudinal beam impedance of a typical pulsed magnet that will be used in the Advanced Light Source. The magnets are of a ferrite window-frame design with a single plate conductor on each side. Two separate power supplies are used to drive current in opposite directions in the two conductors. The continuity of the ferrite yoke is interrupted by two copper plates 1 mm thick in the center of the top and bottom of the window frame. This increases the reluctance of the magnetic path, and thus decreases the flux which couples the beam. The measurements were made by exciting a 1/8'' rod along the beam path through the magnet. This makes a 185 ohm transmission line, and it was terminated in a resistive divider at the exit end. A 3 GHz network analyzer was used to measure S 21 through the magnet, and longitudinal beam impedance was calculated from this data. The impedance is dominated by two low frequency resonances in the magnet winding and drive current. 8 figs

  1. Bioelectrical impedance analysis for bovine milk: Preliminary results

    Science.gov (United States)

    Bertemes-Filho, P.; Valicheski, R.; Pereira, R. M.; Paterno, A. S.

    2010-04-01

    This work reports the investigation and analysis of bovine milk quality by using biological impedance measurements using electrical impedance spectroscopy (EIS). The samples were distinguished by a first chemical analysis using Fourier transform midinfrared spectroscopy (FTIR) and flow citometry. A set of milk samples (100ml each) obtained from 17 different cows in lactation with and without mastitis were analyzed with the proposed technique using EIS. The samples were adulterated by adding distilled water and hydrogen peroxide in a controlled manner. FTIR spectroscopy and flow cytometry were performed, and impedance measurements were made in a frequency range from 500Hz up to 1MHz with an implemented EIS system. The system's phase shift was compensated by measuring saline solutions. It was possible to show that the results obtained with the Bioelectrical Impedance Analysis (BIA) technique may detect changes in the milk caused by mastitis and the presence of water and hydrogen peroxide in the bovine milk.

  2. A comparison between handgrip strength, upper limb fat free mass by segmental bioelectrical impedance analysis (SBIA) and anthropometric measurements in young males

    International Nuclear Information System (INIS)

    Gonzalez-Correa, C H; Caicedo-Eraso, J C; Varon-Serna, D R

    2013-01-01

    The mechanical function and size of a muscle may be closely linked. Handgrip strength (HGS) has been used as a predictor of functional performing. Anthropometric measurements have been made to estimate arm muscle area (AMA) and physical muscle mass volume of upper limb (ULMMV). Electrical volume estimation is possible by segmental BIA measurements of fat free mass (SBIA-FFM), mainly muscle-mass. Relationship among these variables is not well established. We aimed to determine if physical and electrical muscle mass estimations relate to each other and to what extent HGS is to be related to its size measured by both methods in normal or overweight young males. Regression analysis was used to determine association between these variables. Subjects showed a decreased HGS (65.5%), FFM, (85.5%) and AMA (74.5%). It was found an acceptable association between SBIA-FFM and AMA (r 2 = 0.60) and poorer between physical and electrical volume (r 2 = 0.55). However, a paired Student t-test and Bland and Altman plot showed that physical and electrical models were not interchangeable (pt 2 = 0.07) and electrical (r 2 = 0.192) ULMMV showing that muscle mass quantity does not mean muscle strength. Other factors influencing HGS like physical training or nutrition require more research.

  3. The AC Impedance Characteristic of High Power Li4Ti5O12-based Battery Cells

    DEFF Research Database (Denmark)

    Stroe, Ana-Irina; Stroe, Daniel Loan; Swierczynski, Maciej Jozef

    2015-01-01

    This paper studies the impedance characteristics of a fresh 13 Ah high-power lithium titanate oxide (LTO) battery cell and analyses its dependence on the temperature and state-of-charge. The impedance of the battery cell was measured by means of the electrochemical impedance spectroscopy (EIS......) technique for the entire state-of-charge (SOC) interval and considering five temperatures between 5oC and 45oC. By analyzing the measured impedance spectra of the LTO-based battery cell, it was found out that the cell’s impedance is extremely dependent on the operating conditions. By further processing...

  4. Development of the impedance void meter

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Moon Ki; Song, Chul Hwa; Won, Soon Yeon; Kim, Bok Deuk [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    An impedance void meter is developed to measure the area-averaged void fraction. Its basic principle is based on the difference in the electrical conductivity between phases. Several methods of measuring void fraction are briefly reviewed and the reason why this type of void meter is chosen to develop is discussed. Basic principle of the measurement is thoroughly described and several design parameters to affect the overall function are discussed in detail. As example of applications is given for vertical air-water flow. It is shown that the current design has good dynamic response as well as very fine spatial resolution. (Author) 47 refs., 37 figs.

  5. Variational constraints for electrical-impedance tomography

    International Nuclear Information System (INIS)

    Berryman, J.G.; Kohn, R.V.

    1990-01-01

    The task of electrical-impedance tomography is to invert boundary measurements for the conductivity distribution of a body. This inverse problem can be formulated so the primary data are the measured powers dissipated across injection electrodes. Then, since these powers are minima of the pertinent (dual) variational principles, feasibility constraints can be found for the nonlinear inversion problem. When power may be measured accurately, the existence of these dual variational principles implies that any exact solution must lie at a point of intersection of the two feasibility boundaries

  6. Different radiation impedance models for finite porous materials

    DEFF Research Database (Denmark)

    Nolan, Melanie; Jeong, Cheol-Ho; Brunskog, Jonas

    2015-01-01

    The Sabine absorption coefficients of finite absorbers are measured in a reverberation chamber according to the international standard ISO 354. They vary with the specimen size essentially due to diffraction at the specimen edges, which can be seen as the radiation impedance differing from...... the infinite case. Thus, in order to predict the Sabine absorption coefficients of finite porous samples, one can incorporate models of the radiation impedance. In this study, different radiation impedance models are compared with two experimental examples. Thomasson’s model is compared to Rhazi’s method when...

  7. Coupling Impedance of the CERN SPS beam position monitors

    CERN Document Server

    Salvant, B; Boccard, C; Caspers, Friedhelm; Grudiev, A; Jones, R; Métral, E; Rumolo, G; Zannini, C; Spataro, B; Alesini, D; Migliorati, M; Roncarolo, F; Calaga, R

    2010-01-01

    A detailed knowledge of the beam coupling impedance of the CERN Super Proton Synchrotron (SPS) is required in order to operate this machine with a higher intensity for the foreseen Large Hadron Collider (LHC) luminosity upgrade. A large number of Beam Position Monitors (BPMs) is currently installed in the SPS, and this is why their contribution to the SPS impedance has to be assessed. This paper focuses on electromagnetic (EM) simulations and bench measurements of the longitudinal and transverse impedance generated by the horizontal and vertical BPMs installed in the SPS machine.

  8. Impedance analysis of nanostructured iridium oxide electrocatalysts

    International Nuclear Information System (INIS)

    Sunde, Svein; Lervik, Ingrid Anne; Tsypkin, Mikhail; Owe, Lars-Erik

    2010-01-01

    Impedance data were collected for nanostructured iridium oxide (NIROF) at potentials below those at which the oxygen evolution reaction commences. The measurements included thin oxide films covered by a protective Nafion TM layer and thicker composite Nafion TM -oxide electrodes. The time constants for the low-frequency diffusion process were approximately the same for both types of electrodes, indicating diffusion in individual particles in the porous electrode rather than across the film. The diffusion process involves trapping of the diffusion species. The impedance data indicated that there were no significant variations in conductivity of the oxides with potential, as opposed to what appears to be the case for anodically formed iridium oxide films (AIROF). This is interpreted to reflect differences in electronic structure between NIROF and AIROF.

  9. Cutting tool wear monitoring with the use of impedance layers

    OpenAIRE

    Sadílek, Marek; Kratochvíl, Jiří; Petrů, Jana; Čep, Robert; Zlámal, Tomáš; Stančeková, Dana

    2014-01-01

    The article deals with problems of cutting process monitoring in real time. It is focused on tool wear by means of impedance layers applied on ceramic cutting inserts. In the experimental part the cutting process is monitored using electrical resistance measurement. The results are compared and verified using the monitored cutting temperature and tool wear. The testing of impedance layers is reasonable mainly for cutting edge diagnostics. The width of this layer determines the wear allowance ...

  10. MD 349: Impedance Localization with AC-dipole

    CERN Document Server

    Biancacci, Nicolo; Metral, Elias; Salvant, Benoit; Papotti, Giulia; Persson, Tobias Hakan Bjorn; Tomas Garcia, Rogelio; CERN. Geneva. ATS Department

    2016-01-01

    The purpose of this MD is to measure the distribution of the transverse impedance of the LHC by observing the phase advance variation with intensity between the machine BPMs. Four injected bunches with different intensities are excited with an AC dipole and the turn by turn data is acquired from the BPM system. Through post-processing analysis the phase variation along the machine is depicted and, from this information, first conclusions of the impedance distribution can be drawn.

  11. [The future of vascular medicine].

    Science.gov (United States)

    Kroeger, K; Luther, B

    2014-10-01

    In the future vascular medicine will still have a great impact on health of people. It should be noted that the aging of the population does not lead to a dramatic increase in patient numbers, but will be associated with a changing spectrum of co-morbidities. In addition, vascular medical research has to include the intensive care special features of vascular patients, the involvement of vascular medicine in a holistic concept of fast-track surgery, a geriatric-oriented intensive monitoring and early geriatric rehabilitation. For the future acceptance of vascular medicine as a separate subject area under delimitation of cardiology and radiology is important. On the other hand, the subject is so complex and will become more complex in future specialisations that mixing of surgery and angiology is desirable, with the aim to preserve the vascular surgical knowledge and skills on par with the medical and interventional measures and further develop them. Only large, interdisciplinary guided vascular centres will be able to provide timely diagnosis and therapy, to deal with the growing multi-morbidity of the patient, to perform complex therapies even in an acute emergency and due to sufficient number of cases to present with well-trained and experienced teams. These requirements are mandatory to decrease patients' mortality step by step. Georg Thieme Verlag KG Stuttgart · New York.

  12. Y-Source Impedance Network

    DEFF Research Database (Denmark)

    Siwakoti, Yam Prasad; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    This letter introduces a new versatile Y-shaped impedance network for realizing converters that demand a very high-voltage gain, while using a small duty ratio. To achieve that, the proposed network uses a tightly coupled transformer with three windings, whose obtained gain is presently not matched...... by existing networks operated at the same duty ratio. The proposed impedance network also has more degrees of freedom for varying its gain, and hence, more design freedom for meeting requirements demanded from it. This capability has been demonstrated by mathematical derivation, and proven in experiment...

  13. IMPEDANCE SPECTROSCOPY OF POLYCRYSTALLINE TIN DIOXIDE FILMS

    Directory of Open Access Journals (Sweden)

    D. V. Adamchuck

    2016-01-01

    Full Text Available The aim of this work is the analysis of the influence of annealing in an inert atmosphere on the electrical properties and structure of non-stoichiometric tin dioxide films by means of impedance spectroscopy method. Non-stoichiometric tin dioxide films were fabricated by two-step oxidation of metallic tin deposited on the polycrystalline Al2O3 substrates by DC magnetron sputtering. In order to modify the structure and stoichiometric composition, the films were subjected to the high temperature annealing in argon atmosphere in temperature range 300–800 °С. AC-conductivity measurements of the films in the frequency range 20 Hz – 2 MHz were carried out. Variation in the frequency dependencies of the real and imaginary parts of the impedance of tin dioxide films was found to occur as a result of high-temperature annealing. Equivalent circuits for describing the properties of films with various structure and stoichiometric composition were proposed. Possibility of conductivity variation of the polycrystalline tin dioxide films as a result of аnnealing in an inert atmosphere was demonstrated by utilizing impedance spectroscopy. Annealing induces the recrystallization of the films, changing in their stoichiometry as well as increase of the sizes of SnO2 crystallites. Variation of electrical conductivity and structure of tin dioxide films as a result of annealing in inert atmosphere was confirmed by X-ray diffraction analysis. Analysis of the impedance diagrams of tin dioxide films was found to be a powerful tool to study their electrical properties. 

  14. Validation of Taiwan Performance-Based Instrumental Activities of Daily Living (TPIADL), a Performance- Based Measurement of Instrumental Activities of Daily Living for Patients with Vascular Cognitive Impairment.

    Science.gov (United States)

    Chen, Hui-Mei; Lin, Hsiu-Fen; Huang, Mei-Feng; Chang, Chun-Wei; Yeh, Yi-Chun; Lo, Yi-Ching; Yen, Cheng-Fang; Chen, Cheng-Sheng

    2016-01-01

    Patients with cerebrovascular diseases often presented both cognitive and physical impairment. Disability in everyday functioning involving cognitive impairment among patients may be hard to completely rely on informants' reports, as their reports may be confounded with physical impairment. The aim of this study was to validate a performance-based measure of functional assessment, the Taiwan Performance-Based Instrumental Activities of Daily Living (TPIADL), for vascular cognitive impairment (VCI) by examining its psychometric properties and diagnostic accuracy. Ninety-seven patients with cerebrovascular diseases, including 30 with vascular dementia (VaD), 28 with mild cognitive impairment and 39 with no cognitive impairment, and 49 healthy control adults were recruited during study period. The TPIADL, as well as the Mini Mental State Examination (MMSE), Lawton-IADL and Barthel Index (BI), were performed. The internal consistency, convergent and criteria validity of the TPIADL were examined. Cronbach's alpha of the TPIADL test was 0.84. The TPIADL scores were significantly correlated with the Lawton IADL (r = -0.587, p cognitive domain of Lawton IADL (r = -0.663) than with physical domain of Lawton IADL (r = -0.541). The area under the relative operating characteristic curve was 0.888 (95% CI = 0.812-0.965) to differentiate VaD from other groups. The optimal cut-off point of the TPIADL for detecting VaD was 6/7, which gives a sensitivity of 73.3% and a specificity of 84.5%. The TPIADL is a brief and sensitive tool for the detection of IADL impairment in patients with VaD.

  15. Validation of Taiwan Performance-Based Instrumental Activities of Daily Living (TPIADL, a Performance- Based Measurement of Instrumental Activities of Daily Living for Patients with Vascular Cognitive Impairment.

    Directory of Open Access Journals (Sweden)

    Hui-Mei Chen

    Full Text Available Patients with cerebrovascular diseases often presented both cognitive and physical impairment. Disability in everyday functioning involving cognitive impairment among patients may be hard to completely rely on informants' reports, as their reports may be confounded with physical impairment. The aim of this study was to validate a performance-based measure of functional assessment, the Taiwan Performance-Based Instrumental Activities of Daily Living (TPIADL, for vascular cognitive impairment (VCI by examining its psychometric properties and diagnostic accuracy.Ninety-seven patients with cerebrovascular diseases, including 30 with vascular dementia (VaD, 28 with mild cognitive impairment and 39 with no cognitive impairment, and 49 healthy control adults were recruited during study period. The TPIADL, as well as the Mini Mental State Examination (MMSE, Lawton-IADL and Barthel Index (BI, were performed. The internal consistency, convergent and criteria validity of the TPIADL were examined.Cronbach's alpha of the TPIADL test was 0.84. The TPIADL scores were significantly correlated with the Lawton IADL (r = -0.587, p <0.01. Notably, the TPIADL had a higher correlation coefficient with the cognitive domain of Lawton IADL (r = -0.663 than with physical domain of Lawton IADL (r = -0.541. The area under the relative operating characteristic curve was 0.888 (95% CI = 0.812-0.965 to differentiate VaD from other groups. The optimal cut-off point of the TPIADL for detecting VaD was 6/7, which gives a sensitivity of 73.3% and a specificity of 84.5%.The TPIADL is a brief and sensitive tool for the detection of IADL impairment in patients with VaD.

  16. Regional cerebral blood flow levels as measured by xenon-CT in vascular territorial low-density areas after subarachnoid hemorrhage are not always ischemic

    International Nuclear Information System (INIS)

    Fainardi, E.; Tagliaferri, M.F.; Compagnone, C.; Tanfani, A.; Cocciolo, F.; Targa, L.; Chieregato, A.; Battaglia, R.; Frattarelli, M.; Pascarella, R.

    2006-01-01

    The aim of this study was to assess regional cerebral blood flow (rCBV) in areas of CT hypoattenuation appearing in the postoperative period in patients treated for aneurysmal subarachnoid hemorrhage (SAH) using xenon-enhanced CT scanning (Xe-CT). We analyzed 15 patients (5 male and 10 female; mean age 49.7±12.1 years) with SAH on CT performed on admission to hospital and who showed a low-density area within a well-defined vascular territory on CT scans after clipping or coiling of a saccular aneurysm. All zones of hypoattenuation were larger than 1 cm 2 and showed signs of a mass effect suggesting a subacute phase of evolution. Two aneurysms were detected in two patients. Aneurysms were located in the middle cerebral artery (n=7), in the anterior communicating artery (n=6), in the internal carotid artery (n=3), and in the posterior communicating artery (n=1). Treatments were surgical (n=8), endovascular (n=2) or both (n=1). A total of 36 Xe-CT studies were performed and rCBF values were measured in two different regions of interest (ROI): the low-density area, and an area of normal-appearing brain tissue located symmetrically in the contralateral hemisphere. rCBF levels were significantly lower in the low-density area than in the contralateral normal-appearing area (P 55 ml/100 g per minute) in 2/36 lesions (5.6%). Our study confirmed that rCBF is reduced in new low-density lesions related to specific vascular territories. However, only about one-third of the lesions showed rCBF levels consistent with irreversible ischemia and in a relatively high proportion of lesions, rCBF levels indicated penumbral, oligemic and hyperemic areas. (orig.)

  17. Equivalent complex conductivities representing the effects of T-tubules and folded surface membranes on the electrical admittance and impedance of skeletal muscles measured by external-electrode method

    Science.gov (United States)

    Sekine, Katsuhisa

    2017-12-01

    In order to represent the effects of T-tubules and folded surface membranes on the electrical admittance and impedance of skeletal muscles measured by the external-electrode method, analytical relations for the equivalent complex conductivities of hypothetical smooth surface membranes were derived. In the relations, the effects of each tubule were represented by the admittance of a straight cable. The effects of the folding of a surface membrane were represented by the increased area of surface membranes. The equivalent complex conductivities were represented as summation of these effects, and the effects of the T-tubules were different between the transversal and longitudinal directions. The validity of the equivalent complex conductivities was supported by the results of finite-difference method (FDM) calculations made using three-dimensional models in which T-tubules and folded surface membranes were represented explicitly. FDM calculations using the equivalent complex conductivities suggested that the electrically inhomogeneous structure due to the existence of muscle cells with T-tubules was sufficient for explaining the experimental results previously obtained using the external-electrode method. Results of FDM calculations in which the structural changes caused by muscle contractions were taken into account were consistent with the reported experimental results.

  18. [Impedance between modiolus and different walls of scala tympani].

    Science.gov (United States)

    Du, Qiang; Wang, Zhengmin

    2008-10-01

    To compare the impedance between the modiolus and the inner wall of scala tympani with that between the modiolus and the outer wall of scala tympani. The impedances between the modiolus and the inner wall of scala tympani and the impedance between the modiolus and the outer wall of scala tympani were measured, calculated and compared under different stimulating rates 0.1, 1.0, 10.0 kHz. The impedance between the modiolus and the inner wall of scala tympani is less than that between the modiolus and the outer wall of scala tympani (P < 0.05). To effectively stimulate the residual neurons in the spiral ganglion, the electrodes should be kept close to the inner wall of scale tympani.

  19. Validation of the integration of technology that measures additional "vascular" indices into an ambulatory blood pressure monitoring system.

    Science.gov (United States)

    Kotovskaya, Yulia V; Kobalava, Zhanna D; Orlov, Artemy V

    2014-01-01

    The objective of this study was to validate the novel integration of oscillometric (Vasotens(®)) technology into a BPLab(®) ambulatory blood pressure (BP) monitoring system to measure central BP, the aortic augmentation index, and pulse wave velocity (PWV) compared with the recommended and widely accepted tonometric method. The ARTERY Society guidelines for comparison of PWV measurement techniques were used as the basis for recruitment of 99 individuals (mean age 44±19 years, 52 males). The standard for comparison was the conventional "classic" SphygmoCor device. Accordance of the two methods was satisfactory (r=0.98, mean difference of 2.9±3.5 mmHg for central systolic BP; r=0.98, mean difference of -1.1±2.3 mmHg for central diastolic BP; r=0.83, mean difference of -2.6%±13% for aortic augmentation index; r=0.85, mean difference of 0.69±1.4 for PWV). The performance of Vasotens algorithms using an oscillometric ambulatory BP monitoring system is feasible for accurate diagnosis, risk assessment, and evaluation of the effects of antihypertensive drugs.

  20. Impedance of SOFC electrodes: A review and a comprehensive case study on the impedance of LSM:YSZ cathodes

    DEFF Research Database (Denmark)

    Nielsen, Jimmi; Hjelm, Johan

    2014-01-01

    It was shown through a comprehensive impedance spectroscopy study that the impedance of the classic composite LSM:YSZ (lanthanum strontium manganite and yttria stabilized zirconia) solid oxide fuel cell (SOFC) cathode can be described well with porous electrode theory. Furthermore, it was illustr......It was shown through a comprehensive impedance spectroscopy study that the impedance of the classic composite LSM:YSZ (lanthanum strontium manganite and yttria stabilized zirconia) solid oxide fuel cell (SOFC) cathode can be described well with porous electrode theory. Furthermore......, it was illustrated through a literature review on SOFC electrodes that porous electrode theory not only describes the classic LSM:YSZ SOFC cathode well, but SOFC electrodes in general. The extensive impedance spectroscopy study of LSM:YSZ cathodes consisted of measurements on cathodes with three different sintering...... temperatures and hence different microstructures and varying degrees of LSM/YSZ solid state interactions. LSM based composite cathodes, where YSZ was replaced with CGO was also studied in order to acquire further knowledge on the chemical compatibility between LSM and YSZ. All impedance measurements were...

  1. Broadband Planar 5:1 Impedence Transformer

    Science.gov (United States)

    Ehsan, Negar; Hsieh, Wen-Ting; Moseley, Samuel H.; Wollack, Edward J.

    2015-01-01

    This paper presents a broadband Guanella-type planar impedance transformer that transforms so 50 omega to 10 omega with a 10 dB bandwidth of 1-14GHz. The transformer is designed on a flexible 50 micrometer thick polyimide substrate in microstrip and parallel-plate transmission line topologies, and is Inspired by the traditional 4:1 Guanella transformer. Back-to-back transformers were designed and fabricated for characterization in a 50 omega system. Simulated and measured results are in excellent agreement.

  2. Method for conducting nonlinear electrochemical impedance spectroscopy

    Science.gov (United States)

    Adler, Stuart B.; Wilson, Jamie R.; Huff, Shawn L.; Schwartz, Daniel T.

    2015-06-02

    A method for conducting nonlinear electrochemical impedance spectroscopy. The method includes quantifying the nonlinear response of an electrochemical system by measuring higher-order current or voltage harmonics generated by moderate-amplitude sinusoidal current or voltage perturbations. The method involves acquisition of the response signal followed by time apodization and fast Fourier transformation of the data into the frequency domain, where the magnitude and phase of each harmonic signal can be readily quantified. The method can be implemented on a computer as a software program.

  3. Estimation of non-cardiogenic pulmonary oedema using dual-frequency electrical impedance

    NARCIS (Netherlands)

    Raaijmakers, E.; Faes, T. J.; Meijer, J. M.; Kunst, P. W.; Bakker, J.; Goovaerts, H. G.; Heethaar, R. M.

    1998-01-01

    The study investigates the effects of non-cardiogenic oedema, especially the accumulation of protein in extracellular fluid, on thoracic impedance and proposes a new method of oedema measurement based on an impedance ratio from a dual-frequency measurement. In vitro measurements in a cell containing

  4. A New Method of On-line Grid Impedance Estimation for PV Inverter

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Asiminoaei, Lucian; Blaabjerg, Frede

    2004-01-01

    for on-line measuring the grid impedance is presented. The presented method requires no extra hardware being accommodated by typical PV inverters, sensors and CPU, to provide a fast and low cost approach of on-line impedance measurement. By injecting a non-characteristic harmonic current and measuring...

  5. A novel photoplethysmography technique to derive normalized arterial stiffness as a blood pressure independent measure in the finger vascular bed

    International Nuclear Information System (INIS)

    Tanaka, Gohichi; Sawada, Yukihiro; Kato, Yuichi; Yamakoshi, Ken-ichi; Matsumura, Kenta; Maeda, Kimihito; Horiguchi, Masami; Ohguro, Hiroshi

    2011-01-01

    Stiffening of the small artery may be the earliest sign of arteriosclerosis. However, there is no adequate method for directly assessing small arterial stiffness. In this study, the finger arterial elasticity index (FEI) was defined as the parameter n which denotes the curvilinearity of an exponential model of pressure (P)–volume (V a ) relationship (V a = a − b exp (−nP)). For the original estimation, the FEI was calculated from a compliance index from the finger photoplethysmogram whilst occluding the finger. A simple estimation of the FEI was devised by utilizing normalized pulse volume instead of the compliance index. Both estimations yielded close agreement with the exponential model in healthy young participants (study 1: n = 19). Since the FEI was dependent on finger mean blood pressure, normalized finger arterial stiffness index (FSI) was defined as standardized residual from their relationship: mean and standard deviation (SD) of the FSI were 50 ± 10 (study 2: n = 174). The mean coefficient of variation of the FSI for four measurements was 5.72% (study 3: n = 6). The mean and SD of the FSI in seven arteriosclerotic patients were 100.0 ± 13.5. In conclusion, the FEI and FSI by simple estimation are valid and useful for arteriosclerosis research

  6. Calculation of Impedance from Multibunch Synchronous Phases: Theory and Experimental Results

    International Nuclear Information System (INIS)

    Prabhakar, Shyam

    1998-01-01

    A novel beam-based method for measuring the longitudinal impedance spectrum is demonstrated using experimental data from the PEP-II High Energy Ring (HER). The method uses a digital longitudinal feedback system from which the charge and synchronous phase are measured for every bucket. Calculation of the transfer function from fill shape to synchronous phase yields the impedance seen by the beam at revolution harmonics. The experimentally-derived longitudinal impedance function and lab measurements of the impedance of parked RF cavities are compared to suggest a mechanism for the occasional instability of low-order coupled bunch modes observed in the HER during commissioning in October 1997

  7. Dependency of cardiac rubidium-82 imaging quantitative measures on age, gender, vascular territory, and software in a cardiovascular normal population.

    Science.gov (United States)

    Sunderland, John J; Pan, Xiao-Bo; Declerck, Jerome; Menda, Yusuf

    2015-02-01

    Recent technological improvements to PET imaging equipment combined with the availability of software optimized to calculate regional myocardial blood flow (MBF) and myocardial flow reserve (MFR) create a paradigm shifting opportunity to provide new clinically relevant quantitative information to cardiologists. However, clinical interpretation of the MBF and MFR is entirely dependent upon knowledge of MBF and MFR values in normal populations and subpopulations. This work reports Rb-82-based MBF and MFR measurements for a series of 49 verified cardiovascularly normal subjects as a preliminary baseline for future clinical studies. Forty-nine subjects (24F/25M, ages 41-69) with low probability for coronary artery disease and with normal exercise stress test were included. These subjects underwent rest/dipyridamole stress Rb-82 myocardial perfusion imaging using standard clinical techniques (40 mCi injection, 6-minute acquisition) using a Siemens Biograph 40 PET/CT scanner with high count rate detector option. List mode data was rehistogrammed into 26 dynamic frames (12 × 5 seconds, 6 × 10 seconds, 4 × 20 seconds, 4 × 40 seconds). Cardiac images were processed, and MBF and MFR calculated using Siemens syngo MBF, PMOD, and FlowQuant software using a single compartment Rb-82 model. Global myocardial blood flow under pharmacological stress for the 24 females as measured by PMOD, syngo MBF, and FlowQuant were 3.10 ± 0.72, 2.80 ± 0.66, and 2.60 ± 0.63 mL·minute(-1)·g(-1), and for the 25 males was 2.60 ± 0.84, 2.33 ± 0.75, 2.15 ± 0.62 mL·minute(-1)·g(-1), respectively. Rest flows for PMOD, syngo MBF, and FlowQuant averaged 1.32 ± 0.42, 1.20 ± 0.33, and 1.06 ± 0.38 mL·minute(-1)·g(-1) for the female subjects, and 1.12 ± 0.29, 0.90 ± 0.26, and 0.85 ± 0.24 mL·minute(-1)·g(-1) for the males. Myocardial flow reserves for PMOD, syngo MBF, and FlowQuant for the female normals were calculated to be 2.50 ± 0.80, 2.53 ± 0.67, 2.71 ± 0.90, and 2.50 ± 1.19, 2

  8. Bioprinting for vascular and vascularized tissue biofabrication.

    Science.gov (United States)

    Datta, Pallab; Ayan, Bugra; Ozbolat, Ibrahim T

    2017-03-15

    Bioprinting is a promising technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision. Bioprinting enables the deposition of various biologics including growth factors, cells, genes, neo-tissues and extra-cellular matrix-like hydrogels. Benefits of bioprinting have started to make a mark in the fields of tissue engineering, regenerative medicine and pharmaceutics. Specifically, in the field of tissue engineering, the creation of vascularized tissue constructs has remained a principal challenge till date. However, given the myriad advantages over other biofabrication methods, it becomes organic to expect that bioprinting can provide a viable solution for the vascularization problem, and facilitate the clinical translation of tissue engineered constructs. This article provides a comprehensive account of bioprinting of vascular and vascularized tissue constructs. The review is structured as introducing the scope of bioprinting in tissue engineering applications, key vascular anatomical features and then a thorough coverage of 3D bioprinting using extrusion-, droplet- and laser-based bioprinting for fabrication of vascular tissue constructs. The review then provides the reader with the use of bioprinting for obtaining thick vascularized tissues using sacrificial bioink materials. Current challenges are discussed, a comparative evaluation of different bioprinting modalities is presented and future prospects are provided to the reader. Biofabrication of living tissues and organs at the clinically-relevant volumes vitally depends on the integration of vascular network. Despite the great progress in traditional biofabrication approaches, building perfusable hierarchical vascular network is a major challenge. Bioprinting is an emerging technology to fabricate design-specific tissue constructs due to its ability to create complex, heterocellular structures with anatomical precision

  9. Development of the algorithm of measurement data and tomographic section reconstruction results processing for evaluating the respiratory activity of the lungs using the multi-angle electric impedance tomography

    Science.gov (United States)

    Aleksanyan, Grayr; Shcherbakov, Ivan; Kucher, Artem; Sulyz, Andrew

    2018-04-01

    Continuous monitoring of the patient's breathing by the method of multi-angle electric impedance tomography allows to obtain images of conduction change in the chest cavity during the monitoring. Direct analysis of images is difficult due to the large amount of information and low resolution images obtained by multi-angle electrical impedance tomography. This work presents a method for obtaining a graph of respiratory activity of the lungs based on the results of continuous lung monitoring using the multi-angle electrical impedance tomography method. The method makes it possible to obtain a graph of the respiratory activity of the left and right lungs separately, as well as a summary graph, to which it is possible to apply methods of processing the results of spirography.

  10. Relationship between serum levels of triglycerides and vascular inflammation, measured as COX-2, in arteries from diabetic patients: a translational study

    Science.gov (United States)

    2013-01-01

    Background Inflammation is a common feature in the majority of cardiovascular disease, including Diabetes Mellitus (DM). Levels of pro-inflammatory markers have been found in increasing levels in serum from diabetic patients (DP). Moreover, levels of Cyclooxygenase-2 (COX-2) are increased in coronary arteries from DP. Methods Through a cross-sectional design, patients who underwent CABG were recruited. Vascular smooth muscle cells (VSMC) were cultured and COX-2 was measured by western blot. Biochemical and clinical data were collected from the medical record and by blood testing. COX-2 expression was analyzed in internal mammary artery cross-sections by confocal microscopy. Eventually, PGI2 and PGE2 were assessed from VSMC conditioned media by ELISA. Results Only a high glucose concentration, but a physiological concentration of triglycerides exposure of cultured human VSMC derived from non-diabetic patients increased COX-2 expression .Diabetic patients showed increasing serum levels of glucose, Hb1ac and triglycerides. The bivariate analysis of the variables showed that triglycerides was positively correlated with the expression of COX-2 in internal mammary arteries from patients (r2 = 0.214, P < 0.04). Conclusions We conclude that is not the glucose blood levels but the triglicerydes leves what increases the expression of COX-2 in arteries from DP. PMID:23642086

  11. Impedance-matched Marx generators

    Directory of Open Access Journals (Sweden)

    W. A. Stygar

    2017-04-01

    Full Text Available We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs. The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with LC time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22-Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19-Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  12. Impedance-matched Marx generators

    Science.gov (United States)

    Stygar, W. A.; LeChien, K. R.; Mazarakis, M. G.; Savage, M. E.; Stoltzfus, B. S.; Austin, K. N.; Breden, E. W.; Cuneo, M. E.; Hutsel, B. T.; Lewis, S. A.; McKee, G. R.; Moore, J. K.; Mulville, T. D.; Muron, D. J.; Reisman, D. B.; Sceiford, M. E.; Wisher, M. L.

    2017-04-01

    We have conceived a new class of prime-power sources for pulsed-power accelerators: impedance-matched Marx generators (IMGs). The fundamental building block of an IMG is a brick, which consists of two capacitors connected electrically in series with a single switch. An IMG comprises a single stage or several stages distributed axially and connected in series. Each stage is powered by a single brick or several bricks distributed azimuthally within the stage and connected in parallel. The stages of a multistage IMG drive an impedance-matched coaxial transmission line with a conical center conductor. When the stages are triggered sequentially to launch a coherent traveling wave along the coaxial line, the IMG achieves electromagnetic-power amplification by triggered emission of radiation. Hence a multistage IMG is a pulsed-power analogue of a laser. To illustrate the IMG approach to prime power, we have developed conceptual designs of two ten-stage IMGs with L C time constants on the order of 100 ns. One design includes 20 bricks per stage, and delivers a peak electrical power of 1.05 TW to a matched-impedance 1.22 -Ω load. The design generates 113 kV per stage and has a maximum energy efficiency of 89%. The other design includes a single brick per stage, delivers 68 GW to a matched-impedance 19 -Ω load, generates 113 kV per stage, and has a maximum energy efficiency of 90%. For a given electrical-power-output time history, an IMG is less expensive and slightly more efficient than a linear transformer driver, since an IMG does not use ferromagnetic cores.

  13. The effect of vocal tract impedance on the vocal folds

    DEFF Research Database (Denmark)

    Agerkvist, Finn T.; Selamtzis, Andreas

    2011-01-01

    frontend is used to measure the electroglottograph signal which reflects the opening and closing pattern of the vocal folds. The measurements were carried out for all four modes (Neutral, Curbing, Overdrive and Edge) for the vowel [a] in three different pitches: C3(131 Hz), G3 (196 Hz) and C4 (262Hz......The importance of the interaction between the acoustic impedance of the vocal tract with the flow across the vocal cords is well established. In this paper we are investigating the changes in vocal tract impedance when using the different modes of phonation according to Sadolin [1], going from...... the soft levels of the Neutral mode to the high levels of the fully ‘metallic’ Edge mode. The acoustic impedance of vocal tract as seen from the mouth opening is measured via a microphone placed close to the mouth when exciting the system with a volume velocity source [2]. At the same time a Laryngograph...

  14. Cascaded impedance networks for NPC inverter

    DEFF Research Database (Denmark)

    Li, Ding; Gao, Feng; Loh, Poh Chiang

    2010-01-01

    they are subject to the renewable sources. To date, three distinct types of impedance networks can be summarized for implementing a hybrid source impedance network, which can in principle be combined and cascaded before connected to a NPC inverter by proposed two ways. The resulting cascaded impedance network NPC...

  15. Impedance analysis of acupuncture points and pathways

    International Nuclear Information System (INIS)

    Teplan, Michal; Kukucka, Marek; Ondrejkovicová, Alena

    2011-01-01

    Investigation of impedance characteristics of acupuncture points from acoustic to radio frequency range is addressed. Discernment and localization of acupuncture points in initial single subject study was unsuccessfully attempted by impedance map technique. Vector impedance analyses determined possible resonant zones in MHz region.

  16. Journal bearing impedance descriptions for rotordynamic applications

    NARCIS (Netherlands)

    Childs, D.W.; Moes, H.; Leeuwen, van H.J.

    1977-01-01

    Bearing impedance vectors are introduced for plain journal bearings which define the bearing reaction force components as a function of the bearing motion. Impedance descriptions are developed directly for the approximate Ocvirk (short) and Sommerfeld (long) bearing solutions. The impedance vector

  17. Finger impedance evaluation by means of hand exoskeleton.

    Science.gov (United States)

    Fiorilla, Angelo Emanuele; Nori, Francesco; Masia, Lorenzo; Sandini, Giulio

    2011-12-01

    Modulation of arm mechanical impedance is a fundamental aspect for interaction with the external environment and its regulation is essential for stability preservation during manipulation. Even though past research on human arm movements has suggested that models of human finger impedance would benefit the study of neural control mechanisms and the design of novel hand prostheses, relatively few studies have focused on finger and hand impedance. This article touches on the two main aspects of this research topic: first it introduces a mechanical refinement of a device that can be used to effectively measure finger impedance during manipulation tasks; then, it describes a pilot study aimed at identifying the inertia of the finger and the viscous and elastic properties of finger muscles. The proposed wearable exoskeleton, which has been designed to measure finger posture and impedance modulation while leaving the palm free, is capable of applying fast displacements while monitoring the interaction forces between the human finger and the robotic links. Moreover, due to the relatively small inertia of the fingers, it allows us to meet some stringent specifications, performing relatively large displacements (~45°) before the stretch reflex intervenes (~25 ms). The results of measurements on five subjects show that inertia, damping, and stiffness can be effectively identified and that the parameters obtained are comparable with values from previous studies.

  18. Impedance aspect of charge storage at graphite and glassy carbon electrodes in potassium hexacyanoferrate (II redox active electrolyte

    Directory of Open Access Journals (Sweden)

    Katja Magdić

    2016-04-01

    Full Text Available Different types of charge storage mechanisms at unmodified graphite vs. glassy carbon electrodes in acid sulphate supporting solution containing potassium hexacyanoferrate (II redox active electrolyte, have been revealed by electrochemical impedance spectroscopy and supported by cyclic voltammetry experiments. Reversible charge transfer of Fe(CN63-/4- redox reaction detected by assessment of CVs of glassy carbon electrode, is in impedance spectra indicated by presence of bulk diffusion impedance and constant double-layer/pseudocapacitive electrode impedance compared to that measured in the pure supporting electrolyte. Some surface retention of redox species detected by assessment of CVs of graphite electrode is in impedance spectra indicated by diffusion impedance coupled in this case by diminishing of double-layer/pseudo­capacitive impedance compared to that measured in the pure supporting electrolyte. This phenomenon is ascribed to contribution of additional pseudocapacitive impedance generated by redox reaction of species confined at the electrode surface.

  19. Smart Multi-Frequency Bioelectrical Impedance Spectrometer for BIA and BIVA Applications.

    Science.gov (United States)

    Harder, Rene; Diedrich, Andre; Whitfield, Jonathan S; Buchowski, Macie S; Pietsch, John B; Baudenbacher, Franz J

    2016-08-01

    Bioelectrical impedance analysis (BIA) is a noninvasive and commonly used method for the assessment of body composition including body water. We designed a small, portable and wireless multi-frequency impedance spectrometer based on the 12 bit impedance network analyzer AD5933 and a precision wide-band constant current source for tetrapolar whole body impedance measurements. The impedance spectrometer communicates via Bluetooth with mobile devices (smart phone or tablet computer) that provide user interface for patient management and data visualization. The export of patient measurement results into a clinical research database facilitates the aggregation of bioelectrical impedance analysis and biolectrical impedance vector analysis (BIVA) data across multiple subjects and/or studies. The performance of the spectrometer was evaluated using a passive tissue equivalent circuit model as well as a comparison of body composition changes assessed with bioelectrical impedance and dual-energy X-ray absorptiometry (DXA) in healthy volunteers. Our results show an absolute error of 1% for resistance and 5% for reactance measurements in the frequency range of 3 kHz to 150 kHz. A linear regression of BIA and DXA fat mass estimations showed a strong correlation (r(2)=0.985) between measures with a maximum absolute error of 6.5%. The simplicity of BIA measurements, a cost effective design and the simple visual representation of impedance data enables patients to compare and determine body composition during the time course of a specific treatment plan in a clinical or home environment.

  20. Electrical impedance of layered atherosclerotic plaques on human aortas

    NARCIS (Netherlands)

    C.J. Slager (Cornelis); A.C. Phaff; C.E. Essed; N. Bom (Klaas); J.C.H. Schuurbiers (Johan); P.W.J.C. Serruys (Patrick)

    1992-01-01

    textabstractElectrical impedance measurements were performed on 13 atherosclerotic human aortic segments at 67 measuring spots in order to determine whether or not on the basis of these data a distinction can be made between atherosclerotic lesions and normal tissue. Stenosis localization and