  1. Method for determination of the mean fraction of glandular tissue in individual female breasts using mammography

    International Nuclear Information System (INIS)

    Jansen, J T M; Veldkamp, W J H; Thijssen, M A O; Woudenberg, S van; Zoetelief, J

    2005-01-01

    The nationwide breast cancer screening programme using mammography has been in full operation in the Netherlands since 1997. Quality control of the screening programme has been assigned to the National Expert and Training Centre for Breast Cancer Screening. Limits are set to the mean glandular dose and the centre monitors these for all facilities engaged in the screening programme. This procedure is restricted to the determination of the entrance dose on a 5 cm thick polymethylmethacrylate (PMMA) phantom. The mean glandular dose for a compressed breast is estimated from these data. Individual breasts may deviate largely from this 5 cm PMMA breast model. Not only may the compressed breast size vary from 2 to 10 cm, but breast composition varies also. The mean glandular dose is dependent on the fraction of glandular tissue (glandularity) of the breast. To estimate the risk related to individual mammograms requires the development of a method for determination of the glandularity of individual breasts. A method has been developed to derive the glandularity using the attenuation of mammography x-rays in the breast. The method was applied to a series of mammograms at a screening unit. The results, i.e., a glandularity of 93% within the range of 0 to 1, were comparable with data in the literature. The glandularity as a function of compressed breast thickness is similar to results from other investigators using differing methods

  2. Monte Carlo simulation for the estimation of the glandular breast dose for a digital breast tomosynthesis system

    International Nuclear Information System (INIS)

    Rodrigues, Leonardo; Braz, Delson; Goncalves Magalhaes, Luis Alexandre

    2015-01-01

    Digital breast tomosynthesis (DBT) is a screening and diagnostic modality that acquires images of the breast at multiple angles during a short scan. The Selenia Dimensions (Hologic, Bedford, Mass) DBT system can perform both full-field digital mammography and DBT. The system acquires 15 projections over a 15 deg. angular range (from -7.5 deg. to +7.5 deg.). An important factor in determining the optimal imaging technique for breast tomosynthesis is the radiation dose. In breast imaging, the radiation dose of concern is that deposited in the glandular tissue of the breast because this is the tissue that has a risk of developing cancer. The concept of the normalised mean glandular dose (DgN) has been introduced as the metric for the dose in breast imaging. The DgN is difficult to measure. The Monte Carlo techniques offer an alternative method for a realistic estimation of the radiation dose. The purpose of this work was to use the Monte Carlo code MCNPX technique to generate monoenergetic glandular dose data for estimating the breast tissue dose in tomosynthesis for arbitrary spectra as well as to observe the deposited radiation dose by projection on the glandular portion of the breast in a Selenia Dimensions DBT system. A Monte Carlo simulation of the system was developed to compute the DgN in a craniocaudal view. Monoenergetic X-ray beams from 10 to 49 keV in 1-keV increments were used. The simulation utilised the assumption of a homogeneous breast composition and three compositions (0 % glandular, 50 % glandular and 100 % glandular). The glandular and adipose tissue compositions were specified according ICRU Report 44. A skin layer of 4 mm was assumed to encapsulate the breast on all surfaces. The breast size was varied using the chest wall-to-nipple distance (CND) and compressed breast thickness (t). In this work, the authors assumed a CND of 5 cm and the thicknesses ranged from 2 to 8 cm, in steps of 2 cm. The fractional energy absorption increases (up to 44

  3. Computation of the glandular radiation dose in digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Suryanarayanan, Sankararaman; Vedantham, Srinivasan; D'Orsi, Carl; Karellas, Andrew

    2007-01-01

    Tomosynthesis of the breast is currently a topic of intense interest as a logical next step in the evolution of digital mammography. This study reports on the computation of glandular radiation dose in digital tomosynthesis of the breast. Previously, glandular dose estimations in tomosynthesis have been performed using data from studies of radiation dose in conventional planar mammography. This study evaluates, using Monte Carlo methods, the normalized glandular dose (D g N) to the breast during a tomosynthesis study, and characterizes its dependence on breast size, tissue composition, and x-ray spectrum. The conditions during digital tomosynthesis imaging of the breast were simulated using a computer program based on the Geant4 toolkit. With the use of simulated breasts of varying size, thickness and tissue composition, the D g N to the breast tissue was computed for varying x-ray spectra and tomosynthesis projection angle. Tomosynthesis projections centered about both the cranio-caudal (CC) and medio-lateral oblique (MLO) views were simulated. For each projection angle, the ratio of the glandular dose for that projection to the glandular dose for the zero degree projection was computed. This ratio was denoted the relative glandular dose (RGD) coefficient, and its variation under different imaging parameters was analyzed. Within mammographic energies, the RGD was found to have a weak dependence on glandular fraction and x-ray spectrum for both views. A substantial dependence on breast size and thickness was found for the MLO view, and to a lesser extent for the CC view. Although RGD values deviate substantially from unity as a function of projection angle, the RGD averaged over all projections in a complete tomosynthesis study varies from 0.91 to 1.01. The RGD results were fit to mathematical functions and the resulting equations are provided

  4. Average glandular dose in digital mammography and breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Olgar, T. [Ankara Univ. (Turkey). Dept. of Engineering Physics; Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie; Kahn, T.; Gosch, D. [Universitaetsklinikum Leipzig AoeR (Germany). Klinik und Poliklinik fuer Diagnostische und Interventionelle Radiologie

    2012-10-15

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  5. Average glandular dose in digital mammography and breast tomosynthesis

    International Nuclear Information System (INIS)

    Olgar, T.; Universitaetsklinikum Leipzig AoeR; Kahn, T.; Gosch, D.

    2012-01-01

    Purpose: To determine the average glandular dose (AGD) in digital full-field mammography (2 D imaging mode) and in breast tomosynthesis (3 D imaging mode). Materials and Methods: Using the method described by Boone, the AGD was calculated from the exposure parameters of 2247 conventional 2 D mammograms and 984 mammograms in 3 D imaging mode of 641 patients examined with the digital mammographic system Hologic Selenia Dimensions. The breast glandular tissue content was estimated by the Hologic R2 Quantra automated volumetric breast density measurement tool for each patient from right craniocaudal (RCC) and left craniocaudal (LCC) images in 2 D imaging mode. Results: The mean compressed breast thickness (CBT) was 52.7 mm for craniocaudal (CC) and 56.0 mm for mediolateral oblique (MLO) views. The mean percentage of breast glandular tissue content was 18.0 % and 17.4 % for RCC and LCC projections, respectively. The mean AGD values in 2 D imaging mode per exposure for the standard breast were 1.57 mGy and 1.66 mGy, while the mean AGD values after correction for real breast composition were 1.82 mGy and 1.94 mGy for CC and MLO views, respectively. The mean AGD values in 3 D imaging mode per exposure for the standard breast were 2.19 mGy and 2.29 mGy, while the mean AGD values after correction for the real breast composition were 2.53 mGy and 2.63 mGy for CC and MLO views, respectively. No significant relationship was found between the AGD and CBT in 2 D imaging mode and a good correlation coefficient of 0.98 in 3 D imaging mode. Conclusion: In this study the mean calculated AGD per exposure in 3 D imaging mode was on average 34 % higher than for 2 D imaging mode for patients examined with the same CBT.

  6. Breast Glandularity in Malaysian Women from a Full-Field Digital Mammography System

    International Nuclear Information System (INIS)

    Noriah Jamal; Humairah Samad Cheung; Siti Selina Abdul Hamid; Juliana Mahamad Napiah

    2014-01-01

    This study is undertaken to estimate breast glandularity in Malaysian women from a Full-Field Digital mammography System. This study involved 223 women (Malay=100;Chinese=101 and Indian=22) underwent voluntary screening mammography at Breast Centre, International Islamic University Malaysia (IIUM Breast Centre) for the first quarter of year 2009. Those are women aged between 31 to 69 years old (median age, 49 years). Data on miliampere-seconds, kilo voltage and compressed breast thickness for each cranio caudal view are used to estimate breast glandularity for an individual breast. Breast glandularity is calculated using the fitted equation reported earlier. The difference in breast glandularity among ethnic groups was tested for significance using the nonparametric Kruskal-Wallis test. The average breast glandularity estimated in our study, using FFDM system is 52.94±27.63 %. No significant difference was seen in breast glandularity among the ethnic groups (p>0.05, Kruskan Wallis test). Breast glandularity decrease as age increases, up to 60 years old. (author)

  7. Normalized glandular dose (DgN) coefficients for flat-panel CT breast imaging

    International Nuclear Information System (INIS)

    Thacker, Samta C; Glick, Stephen J

    2004-01-01

    The development of new digital mammography techniques such as dual-energy imaging, tomosynthesis and CT breast imaging will require investigation of optimal camera design parameters and optimal imaging acquisition parameters. In optimizing these acquisition protocols and imaging systems it is important to have knowledge of the radiation dose to the breast. This study presents a methodology for estimating the normalized glandular dose to the uncompressed breast using the geometry proposed for flat-panel CT breast imaging. The simulation uses the GEANT 3 Monte Carlo code to model x-ray transport and absorption within the breast phantom. The Monte Carlo software was validated for breast dosimetry by comparing results of the normalized glandular dose (DgN) values of the compressed breast to those reported in the literature. The normalized glandular dose was then estimated for a range of breast diameters from 10 cm to 18 cm using an uncompressed breast model with a homogeneous composition of adipose and glandular tissue, and for monoenergetic x-rays from 10 keV to 120 keV. These data were fit providing expressions for the normalized glandular dose. Using these expressions for the DgN coefficients and input variables such as the diameter, height and composition of the breast phantom, the mean glandular dose for any spectra can be estimated. A computer program to provide normalized glandular dose values has been made available online. In addition, figures displaying energy deposition maps are presented to better understand the spatial distribution of dose in CT breast imaging

  8. Breast dose in mammography is about 30% lower when realistic heterogeneous glandular distributions are considered

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, Andrew M., E-mail: amhern@ucdavis.edu [Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States); Seibert, J. Anthony; Boone, John M. [Departments of Radiology and Biomedical Engineering, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, California 95817 (United States)

    2015-11-15

    Purpose: Current dosimetry methods in mammography assume that the breast is comprised of a homogeneous mixture of glandular and adipose tissues. Three-dimensional (3D) dedicated breast CT (bCT) data sets were used previously to assess the complex anatomical structure within the breast, characterizing the statistical distribution of glandular tissue in the breast. The purpose of this work was to investigate the effect of bCT-derived heterogeneous glandular distributions on dosimetry in mammography. Methods: bCT-derived breast diameters, volumes, and 3D fibroglandular distributions were used to design realistic compressed breast models comprised of heterogeneous distributions of glandular tissue. The bCT-derived glandular distributions were fit to biGaussian functions and used as probability density maps to assign the density distributions within compressed breast models. The MCNPX 2.6.0 Monte Carlo code was used to estimate monoenergetic normalized mean glandular dose “DgN(E)” values in mammography geometry. The DgN(E) values were then weighted by typical mammography x-ray spectra to determine polyenergetic DgN (pDgN) coefficients for heterogeneous (pDgN{sub hetero}) and homogeneous (pDgN{sub homo}) cases. The dependence of estimated pDgN values on phantom size, volumetric glandular fraction (VGF), x-ray technique factors, and location of the heterogeneous glandular distributions was investigated. Results: The pDgN{sub hetero} coefficients were on average 35.3% (SD, 4.1) and 24.2% (SD, 3.0) lower than the pDgN{sub homo} coefficients for the Mo–Mo and W–Rh x-ray spectra, respectively, across all phantom sizes and VGFs when the glandular distributions were centered within the breast phantom in the coronal plane. At constant breast size, increasing VGF from 7.3% to 19.1% lead to a reduction in pDgN{sub hetero} relative to pDgN{sub homo} of 23.6%–27.4% for a W–Rh spectrum. Displacement of the glandular distribution, at a distance equal to 10% of the

  9. Investigation of mean glandular dose versus compressed breast thickness relationship for mammography

    International Nuclear Information System (INIS)

    Bor, D.; Tukel, S.; Olgar, T.; Toklu, T.; Aydin, E.; Akyol, O.

    2008-01-01

    The relationship between the mean glandular dose (MGD) and the compressed breast thickness (CBT) is commonly used for the presentation of mammographic dose survey results and could also be useful for the assessment of individual breast doses retrospectively in case of lack of necessary dosimetric instrumentation. The high data scattering from the best fit reduces the reliability of this technique. The aim of this study was to investigate the accuracy of this relationship using the data collected from a patient survey and phantom experiment. Patients were divided into three different groups according to their breast glandularities, which were predicted from the inspection of previous mammograms. X-ray beam qualities that will be used in patient examinations were determined according to breast thickness and predicted glandularities. The MGD versus CBT relationship for all the examined patients resulted in a poor correlation (R 2 = 0.28). This relationship was separately obtained for each glandularity group and also for sub-groups of specific beam qualities. The best correlation (R 2 = 0.73) was obtained for the fatty breast group and Mo/Mo combination. A low correlation (R 2 = 0.34) was observed in the mid-glandularity group due to inclusion of a wide range of glandularities in this group. In the case of the dense breast group, although the glandularity range was narrow, there were e still high data scattering (R 2 = 0.25). This was probably due to the use of Mo/Rh and Mo/Mo combinations. This is validated by obtaining the MGD-CBT relationship specific to Mo/Mo combination (R 2 = 0.61). (authors)

  10. Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data

    NARCIS (Netherlands)

    Bouwman, R. W.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Schopphoven, S.; Jeukens, C. R. L. P. N.; Veldkamp, W. J. H.; Dance, D. R.

    2015-01-01

    For the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT) phantoms simulating standard model breasts are used. These phantoms consist of slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE). In the last

  11. Glandularity estimation in Japanese women by using a breast model made from mammographic findings of European women

    International Nuclear Information System (INIS)

    Kawaguchi, Ai; Matsunaga, Yuta; Chida, Koichi; Asada, Yasuki; Suzuki, Shoichi

    2016-01-01

    This study aimed to estimate breast glandularity in Japanese women using patient exposure conditions and tissue-equivalent materials by a conventional method. Typical glandularities in Japanese women were compared with those in European women to verify the validity of the average glandular dose estimation manual based on the EUREF protocol. Glandularity was estimated from the data of 600 patients and the model breast of the tissue-equivalent materials which had various amounts of glandular contents and thicknesses. The model breasts were measured to examine the relationships between the thickness of the glandular contents and tube loading by using an automatic exposure control system. Then, equations were established to determine glandularity from patient data. The mean glandularity in the highest compressed breast thickness (CBT) group of 36–45 mm was 72%. The mean CBT of the 184 (31%) patients with glandularities exceeding 100% was 31 mm. Glandularities in patients with CBT of 30–70 mm in the present study were higher compared to those in European women by approximately 10–20%. The results suggest that the model breast of European women might not be a suitable reference standard for more than 30% of Japanese women, who have breasts with lower CBT. (author)

  12. Effect of the glandular composition on digital breast tomosynthesis image quality and dose optimisation

    International Nuclear Information System (INIS)

    Marques, T.; Di Maria, S.; Vaz, P.; Ribeiro, A.; Belchior, A.; Cardoso, J.; Matela, N.; Oliveira, N.; Almeida, P.; Janeiro, L.

    2015-01-01

    In the image quality assessment for digital breast tomosynthesis (DBT), a breast phantom with an average percentage of 50 % glandular tissue is seldom used, which may not be representative of the breast tissue composition of the women undergoing such examination. This work aims at studying the effect of the glandular composition of the breast on the image quality taking into consideration different sizes of lesions. Monte Carlo simulations were performed using the state-of-the-art computer program PENELOPE to validate the image acquisition system of the DBT equipment as well as to calculate the mean glandular dose for each projection image and for different breast compositions. The integrated PENELOPE imaging tool (PenEasy) was used to calculate, in mammography, for each clinical detection task the X-ray energy that maximises the figure of merit. All the 2D cranial-caudal projections for DBT were simulated and then underwent the reconstruction process applying the Simultaneous Algebraic Reconstruction Technique. Finally, through signal-to-noise ratio analysis, the image quality in DBT was assessed. (authors)

  13. CT measurement of breast glandular tissue and its association with testicular cancer

    Energy Technology Data Exchange (ETDEWEB)

    Klang, Eyal [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel); The Chaim Sheba Medical Center, Tel Hashomer (Israel); Rozendorn, Noa; Raskin, Steve; Portnoy, Orith; Sklair, Miri; Marom, Edith M.; Konen, Eli; Amitai, Michal M. [Tel Aviv University, Department of Radiology, Chaim Sheba Medical Center, Tel Aviv (Israel)

    2017-02-15

    To evaluate the associations between breast glandular tissues diameters as determined by CT and b-hCG levels, histological types, tumour spread and prognosis in patients with testicular germ cell tumour. Ninety-four patients with pre-treatment CT scan and markers (b-hCG, AFP, LDH) were retrospectively collected. A radiologist measured diameters in all CT examinations and correlation between diameters and log (b-hCG) was assessed (Pearson's coefficient). The ability of measured diameters to predict lymphatic and distant haematogenous metastatic spread was evaluated (ROC curves). The associations between measured diameter cut-off values of 20 and 25 mm and International Germ Cell Cancer Collaborative Group (IGCCCG) classification, lymphatic and distant haematogenous metastatic spread and histological subtypes were evaluated (chi squared test). Breast glandular diameters correlated to log(b-hCG) (r = 0.579) and predicted distant haematogenous metastatic spread (AUC = 0.78). Worse prognosis (intermediate or poor IGCCCG) was shown for 20 mm (27.3 vs. 4.2 %, p = 0.005) and 25 mm (33.3 vs. 6.1 %, p = 0.014). A diameter of 25 mm was associated with non-seminoma (91.7 vs. 48.8 %, p = 0.005). Breast glandular tissue diameters correlated with log(b-hCG) and predicted distant haematogenous metastases. Twenty and 25 mm were associated with worse prognosis and 25 mm was able to distinguish between seminoma and non-seminoma. (orig.)

  14. Automated Breast Density Computation in Digital Mammography and Digital Breast Tomosynthesis: Influence on Mean Glandular Dose and BIRADS Density Categorization.

    Science.gov (United States)

    Castillo-García, Maria; Chevalier, Margarita; Garayoa, Julia; Rodriguez-Ruiz, Alejandro; García-Pinto, Diego; Valverde, Julio

    2017-07-01

    The study aimed to compare the breast density estimates from two algorithms on full-field digital mammography (FFDM) and digital breast tomosynthesis (DBT) and to analyze the clinical implications. We selected 561 FFDM and DBT examinations from patients without breast pathologies. Two versions of a commercial software (Quantra 2D and Quantra 3D) calculated the volumetric breast density automatically in FFDM and DBT, respectively. Other parameters such as area breast density and total breast volume were evaluated. We compared the results from both algorithms using the Mann-Whitney U non-parametric test and the Spearman's rank coefficient for data correlation analysis. Mean glandular dose (MGD) was calculated following the methodology proposed by Dance et al. Measurements with both algorithms are well correlated (r ≥ 0.77). However, there are statistically significant differences between the medians (P density median values from FFDM are, respectively, 8% and 77% higher than DBT estimations. Both algorithms classify 35% and 55% of breasts into BIRADS (Breast Imaging-Reporting and Data System) b and c categories, respectively. There are no significant differences between the MGD calculated using the breast density from each algorithm. DBT delivers higher MGD than FFDM, with a lower difference (5%) for breasts in the BIRADS d category. MGD is, on average, 6% higher than values obtained with the breast glandularity proposed by Dance et al. Breast density measurements from both algorithms lead to equivalent BIRADS classification and MGD values, hence showing no difference in clinical outcomes. The median MGD values of FFDM and DBT examinations are similar for dense breasts (BIRADS d category). Published by Elsevier Inc.

  15. Relationship of Compressed Breast Thickness and Average Glandular Dose According to Focus/Filter

    International Nuclear Information System (INIS)

    Lee, In Ja

    2009-01-01

    The study examined the relationship between the compressed breast thickness and Average Glandular Dose (AGD) among 1,969 outpatients who went through breast X-ray in a university hospital for 10 months from July 1st, 2007 to April 30th, 2008. Then it analyzed the result acquired from 3,900 cases of Cranio-Caudal (CC) view, especially, when the breasts were compressed (13-15daN). The following is the conclusion driven from the relationship analysis. 1. The subjects aged in 40s and 50s were 2,679 out of 3,900 cases and this figure was 68.69% in all. 2. In terms of distribution depending on focus/filter, 41.0% was Mo/Mo, 34.8% was Mo/Rh, and 24.2% was Rh/Rh. 3. In terms of compressed breast thickness depending on focus/filter, the average thickness was 26.91 mm at Mo/Mo, 38.84 mm at Mo/Rh, and 48.80 mm at Rh/Rh. The average thickness of the entire cases was shown to be 36.27 mm. 4. AGD depending on focus/filter was 1.27 mGy at Mo/Mo, 1.55 mGy at Mo/Rh, and 1.42 mGy at Rh/Rh. The average glandular dose of the entire cases was shown to be 1.43 mGy. 5. The relationship of AGD depending on compressed breast thickness at Mo/Mo was y=0.0318x + 0.470 while it was y=0.0206x + 0.709 at Mo/Rh and y=0.0248x + 0.335 at Mo/Rh. It was highly influenced by the compressed breast thickness, however, more variation was detected at Mo/Mo depending on breast thickness.

  16. Impact of digitalization of mammographic units on average glandular doses in the Flemish Breast Cancer Screening Program

    OpenAIRE

    De Hauwere, An; Thierens, Hubert

    2012-01-01

    The impact of digitalization on the average glandular doses in 49 mammographic units participating in the Flemish Breast Cancer Screening Program was studied. Screen-film was changed to direct digital radiography and computed radiography in 25 and 24 departments respectively. Average glandular doses were calculated before and after digitalization for different PMMA-phantom thicknesses and for groups of 50 successive patients. For the transition from screen-film to computed radiography both ph...

  17. Mean glandular dose measurement on various breast phantom using mammography machine in MINT Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Wan Hazlinda Ismail; Asmaliza Hashim; Abd Aziz Mhd Ramli

    2005-01-01

    Until recently, mammography have been the primary means of detecting early breast cancer. Although there is a risk of radiation- induced carcinogenesis associated with the x-ray examination of the female breast, but this risk is small compared to its benefits with modern equipment and technique. Therefore, it is important to determine the dose of the tissue at risk from radiation exposure by measuring the mean glandular dose (MGD). This can help minimize the risk to the patient. This paper describe the MGD measurement done on various types and thickness of breast phantom using a Bennett mammography machine model DMF-150 in the Medical Physics laboratory at the Malaysian Institute for Nuclear Technology Research (MINT). Results of this study are discussed in this paper. (Author)

  18. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, Biomedical Engeering Graduate Group, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered

  19. Preliminary results of the average glandular dose to the breast with TLDS measure is computed as the conversion factors

    International Nuclear Information System (INIS)

    Sardo, Luiz T.L.; Almeida, Claudio D.; Coutinho, Celia M.C.

    2013-01-01

    At mammography exams there is a risk of a breast cancer induced from the absorbed dose by the glandular tissue. According to the National Institute of Cancer, INCA, breast cancer is the second type most frequent in the world and the most common among women, therefore the necessity of monitoring the mean glandular dose, D G . Measuring methods of D G were established by some authors. Among the established methods the method of Dance is one of the most known. In this study was utilized a measurement method realized with TL dosimeters inserted in a breast tissue equivalent phantom, BTE, with 46% of glandularity and exposed using Mo/Mo and Mo/Rh target/filter combination and 28kV. To ensure this measurement method the results were compared with a calculation method, used by Dance, of D G from the measurement of incident air kerma, K i , and conversion factors to consider mainly the beam quality, the compressed thickness and the glandularity of the breast. The results of the comparison of the D G measurement with the obtained dose by the method of Dance demonstrated that for the thickness of 4.0 and 6.0 cm the doses were consistent. For the thickness of 5.0 cm the difference was higher, indicating that the glandularity may influence, suggesting further investigation. (author)

  20. Estimation of average glandular dose depending on the thickness of the breast

    International Nuclear Information System (INIS)

    Real, Jessica V.; Luz, Renata M. da; Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da

    2014-01-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient

  1. Estimation of average glandular dose depending on the thickness of the breast; Estimativa da dose glandular media em funcao da espessura da mama

    Energy Technology Data Exchange (ETDEWEB)

    Real, Jessica V.; Luz, Renata M. da, E-mail: jessica.real@pucrs.br, E-mail: renata.luz@pucrs.br [Hospital Sao Lucas (HSL/PUCRS), Porto Alegre, RS (Brazil); Fröhlich, Bruna D.; Pertile, Alessandra S.; Silva, Ana Maria Marques da, E-mail: bruna.frohlich@acad.pucrs.br, E-mail: lessandra.pertile@acad.pucrs.br, E-mail: ana.marques@pucrs.br [Pontificia Universidade Catolica do Rio Grande do Sul (PUCRS), Porto Alegre, RS (Brazil)

    2014-07-01

    Breast cancer is the most common type of cancer in women worldwide. Mammography is, to date, the most efficient method for detecting an abnormality in the patient's breast. It is a technique of imaging diagnostic that requires special care because radiographs without adequate quality may lead to a false diagnosis and lead to the need for a repeat examination, increasing the dose of radiation in the patient. This study aimed to evaluate the average glandular dose (AGD), depending on the breast thickness in patients undergoing routine tests, with a digital computer radiography processing system. Analyzed 30 exhibitions in patients aged (65 ± 12) years, in the right and left caudal skull projections, for breasts with thicknesses between 45 mm and 50 mm. The calculated value of the AGD for this track thickness was (1.600 ± 0.009) mGy. The performance of mammography quality control tests was satisfactory and the AGD values obtained for the chosen thickness range is acceptable, since the threshold achievable is 1.6 mGy and the acceptable is 2 mGy. In Brazil, it is only required the input dose calculation in skin for 45 mm breasts. However, the calculation of AGD is required for different thicknesses of the breast, to identify the best mammographic pattern aiming at better image quality at the lowest dose provided the patient.

  2. Evaluation of exposure in mammography: limitations of average glandular dose and proposal of a new quantity

    International Nuclear Information System (INIS)

    Geeraert, N.; Bosmans, H.; Klausz, R.; Muller, S.; Bloch, I.

    2015-01-01

    The radiation risk in mammography is traditionally evaluated using the average glandular dose. This quantity for the average breast has proven to be useful for population statistics and to compare exposure techniques and systems. However it is not indicating the individual radiation risk based on the individual glandular amount and distribution. Simulations of exposures were performed for six appropriate virtual phantoms with varying glandular amount and distribution. The individualised average glandular dose (iAGD), i.e. the individual glandular absorbed energy divided by the mass of the gland, and the glandular imparted energy (GIE), i.e. the glandular absorbed energy, were computed. Both quantities were evaluated for their capability to take into account the glandular amount and distribution. As expected, the results have demonstrated that iAGD reflects only the distribution, while GIE reflects both the glandular amount and distribution. Therefore GIE is a good candidate for individual radiation risk assessment. (authors)

  3. Average glandular dose in digital mammography and digital breast tomosynthesis: comparison of phantom and patient data

    International Nuclear Information System (INIS)

    Bouwman, R W; Van Engen, R E; Den Heeten, G J; Broeders, M J M; Veldkamp, W J H; Young, K C; Dance, D R; Schopphoven, S; Jeukens, C R L P N

    2015-01-01

    For the evaluation of the average glandular dose (AGD) in digital mammography (DM) and digital breast tomosynthesis (DBT) phantoms simulating standard model breasts are used. These phantoms consist of slabs of polymethyl methacrylate (PMMA) or a combination of PMMA and polyethylene (PE). In the last decades the automatic exposure control (AEC) increased in complexity and became more sensitive to (local) differences in breast composition. The question is how well the AGD estimated using these simple dosimetry phantoms agrees with the average patient AGD. In this study the AGDs for both dosimetry phantoms and for patients have been evaluated for 5 different x-ray systems in DM and DBT modes. It was found that the ratios between patient and phantom AGD did not differ considerably using both dosimetry phantoms. These ratios averaged over all breast thicknesses were 1.14 and 1.15 for the PMMA and PMMA-PE dosimetry phantoms respectively in DM mode and 1.00 and 1.02 in the DBT mode. These ratios were deemed to be sufficiently close to unity to be suitable for dosimetry evaluation in quality control procedures. However care should be taken when comparing systems for DM and DBT since depending on the AEC operation, ratios for particular breast thicknesses may differ substantially (0.83–1.96). Although the predictions of both phantoms are similar we advise the use of PMMA  +  PE slabs for both DM and DBT to harmonize dosimetry protocols and avoid any potential issues with the use of spacers with the PMMA phantoms. (paper)

  4. Estimates of Average Glandular Dose with Auto-modes of X-ray Exposures in Digital Breast Tomosynthesis

    Directory of Open Access Journals (Sweden)

    Izdihar Kamal

    2015-05-01

    Full Text Available Objectives: The aim of this research was to examine the average glandular dose (AGD of radiation among different breast compositions of glandular and adipose tissue with auto-modes of exposure factor selection in digital breast tomosynthesis. Methods: This experimental study was carried out in the National Cancer Society, Kuala Lumpur, Malaysia, between February 2012 and February 2013 using a tomosynthesis digital mammography X-ray machine. The entrance surface air kerma and the half-value layer were determined using a 100H thermoluminescent dosimeter on 50% glandular and 50% adipose tissue (50/50 and 20% glandular and 80% adipose tissue (20/80 commercially available breast phantoms (Computerized Imaging Reference Systems, Inc., Norfolk, Virginia, USA with auto-time, auto-filter and auto-kilovolt modes. Results: The lowest AGD for the 20/80 phantom with auto-time was 2.28 milliGray (mGy for two dimension (2D and 2.48 mGy for three dimensional (3D images. The lowest AGD for the 50/50 phantom with auto-time was 0.97 mGy for 2D and 1.0 mGy for 3D. Conclusion: The AGD values for both phantoms were lower against a high kilovolt peak and the use of auto-filter mode was more practical for quick acquisition while limiting the probability of operator error.

  5. Preliminary results of the average glandular dose to the breast with TLDS measure is computed as the conversion factors; Resultados preliminares da dose glandular media na mama medida com TLDS e calculada atraves de fatores de conversao

    Energy Technology Data Exchange (ETDEWEB)

    Sardo, Luiz T.L.; Almeida, Claudio D.; Coutinho, Celia M.C., E-mail: ltsardo@yahoo.com.br, E-mail: claudio@ird.gov.br, E-mail: celia@ird.gov.br [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil)

    2013-07-01

    At mammography exams there is a risk of a breast cancer induced from the absorbed dose by the glandular tissue. According to the National Institute of Cancer, INCA, breast cancer is the second type most frequent in the world and the most common among women, therefore the necessity of monitoring the mean glandular dose, D{sub G}. Measuring methods of D{sub G} were established by some authors. Among the established methods the method of Dance is one of the most known. In this study was utilized a measurement method realized with TL dosimeters inserted in a breast tissue equivalent phantom, BTE, with 46% of glandularity and exposed using Mo/Mo and Mo/Rh target/filter combination and 28kV. To ensure this measurement method the results were compared with a calculation method, used by Dance, of D{sub G} from the measurement of incident air kerma, K{sub i}, and conversion factors to consider mainly the beam quality, the compressed thickness and the glandularity of the breast. The results of the comparison of the D{sub G} measurement with the obtained dose by the method of Dance demonstrated that for the thickness of 4.0 and 6.0 cm the doses were consistent. For the thickness of 5.0 cm the difference was higher, indicating that the glandularity may influence, suggesting further investigation. (author)

  6. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  7. Oncoplastic Resection of Retroareolar Breast Cancer: Central Quadrantectomy and Reconstruction by Local Skin-Glandular Flap

    International Nuclear Information System (INIS)

    Naguib, S.F.

    2006-01-01

    Background: Patients with central breast neoplasms account for 5 to 20% of breast cancer cases and, for a long time, they have been denied Breast Conservation Surgery (BCS) and conventionally treated with mastectomy. The high incidence of Nipple-Areola-Complex (NAC) involvement usually associated with these tumors necessitates nipple and areolar resection together with an adequate safety margin around the tumor, which yields an unacceptable cosmetic result. With the help of Oncoplastic Surgical Techniques, BCS can be offered to these patients. In this study central quadrantectomy and breast reconstruction by an infero-Iaterally based pedicled flap were evaluated. Patients and Methods: This study comprised 23 women with central breast tumors treated at the National Cancer Institute (NC]), Cairo University and at the Aswan Cancer Center, Egyptian Ministry of Health. Their ages ranged from 31 to 62 years (mean: 48.4±10.2 years). Twenty-two had a palpable mass, while only I had Paget's disease of the nipple without mass. The size of their tumors ranged from 4 to 33mm (mean: 16.9±8.6mm). Only 9 women showed clinical suspicion of NAC involvement in the form of nipple retraction. Seventeen cases had their tumors strictly in the retro-areolar region, while 5 had tumors extending for a maximum of I.5Cm beyond the areolar edge. All patients underwent central quadrantec-tomy with NAC resection removing a cylinder of breast tissue reaching down to the pectoral muscle together with axillary dissection. Advancement of an infero-Iaterally based skin-glandular flap was then carried out. All patients received adjuvant radiotherapy with or without chemotherapy or hormonal therapy. Results: Fourteen patients showed pathological evidence of nipple infiltration (60.8%). The free safety margin (SM) ranged from 9 to 13mm (mean: 10. 0.9mm). This could be accomplished from the first attempt in 18 patients; however, in 5 patients a second wider excision was needed to obtain an adequate

  8. Estimating average glandular dose by measuring glandular rate in mammograms

    International Nuclear Information System (INIS)

    Goto, Sachiko; Azuma, Yoshiharu; Sumimoto, Tetsuhiro; Eiho, Shigeru

    2003-01-01

    The glandular rate of the breast was objectively measured in order to calculate individual patient exposure dose (average glandular dose) in mammography. By employing image processing techniques and breast-equivalent phantoms with various glandular rate values, a conversion curve for pixel value to glandular rate can be determined by a neural network. Accordingly, the pixel values in clinical mammograms can be converted to the glandular rate value for each pixel. The individual average glandular dose can therefore be calculated using the individual glandular rates on the basis of the dosimetry method employed for quality control in mammography. In the present study, a data set of 100 craniocaudal mammograms from 50 patients was used to evaluate our method. The average glandular rate and average glandular dose of the data set were 41.2% and 1.79 mGy, respectively. The error in calculating the individual glandular rate can be estimated to be less than ±3%. When the calculation error of the glandular rate is taken into consideration, the error in the individual average glandular dose can be estimated to be 13% or less. We feel that our method for determining the glandular rate from mammograms is useful for minimizing subjectivity in the evaluation of patient breast composition. (author)

  9. Validation of mean glandular dose values provided by a digital breast tomosynthesis system in Brazil

    International Nuclear Information System (INIS)

    Beraldo O, B.; Paixao, L.; Donato da S, S.; Araujo T, M. H.; Nogueira, M. S.

    2014-08-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality that provides quasi-three-dimensional structural information of the breast and has strong promise to improve the differentiation of normal tissue and suspicious masses reducing the tissue overlaps. DBT images are reconstructed from a sequence of low-dose X-ray projections of the breast acquired at a small number of angles over a limited angular range. The Ho logic Selen ia Dimensions system is equipped with an amorphous Selenium (a-Se) detector layer of 250 μm thickness and a 70 μm pixel pitch. Studies are needed to determine the radiation dose of patients that are undergoing this emerging procedure to compare with the results obtained in DBT images. The mean glandular dose (D G ) is the dosimetric quantity used in quality control of the mammographic systems. The aim of this work is to validate D G values for different breast thicknesses provided by a Ho logic Selen ia Dimensions system using a DBT mode in comparison with the same results obtained by a calibrated 90 X 5-6M-model Radcal ionization chamber. D G values were derived from the incident air kerma (K i ) measurements and tabulated conversion coefficients that are dependent on the half value layer (HVL) of the X-ray spectrum. Voltage and tube loading values were recorded in irradiations using W/Al anode/filter combination, automatic exposure control mode and polymethyl methacrylate (PMMA) slabs which simulate different breast thicknesses. For K i measurements, the ionization chamber was positioned at 655 mm from the focus and the same radiographic technique values were selected with the manual mode. D G values for a complete procedure ranged from 0.9 ± 0.1 to 3.7 ± 0.4 mGy. The results for different breast thicknesses are in accordance with values obtained by DBT images and with acceptable levels established by the Commission of the European Communities (Cec) and the International Atomic Energy Agency (IAEA). This work contributes to

  10. Validation of mean glandular dose values provided by a digital breast tomosynthesis system in Brazil

    Energy Technology Data Exchange (ETDEWEB)

    Beraldo O, B.; Paixao, L.; Donato da S, S. [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Post-graduation in Sciences and Technology of Radiations Minerals and Materials, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil); Araujo T, M. H. [Dr Maria Helena Araujo Teixeira Clinic, Guajajaras 40, 30180-100 Belo Horizonte (Brazil); Nogueira, M. S., E-mail: bbo@cdtn.br [Centro de Desenvolvimento da Tecnologia Nuclear / CNEN, Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte (Brazil)

    2014-08-15

    Digital breast tomosynthesis (DBT) is an emerging imaging modality that provides quasi-three-dimensional structural information of the breast and has strong promise to improve the differentiation of normal tissue and suspicious masses reducing the tissue overlaps. DBT images are reconstructed from a sequence of low-dose X-ray projections of the breast acquired at a small number of angles over a limited angular range. The Ho logic Selen ia Dimensions system is equipped with an amorphous Selenium (a-Se) detector layer of 250 μm thickness and a 70 μm pixel pitch. Studies are needed to determine the radiation dose of patients that are undergoing this emerging procedure to compare with the results obtained in DBT images. The mean glandular dose (D{sub G}) is the dosimetric quantity used in quality control of the mammographic systems. The aim of this work is to validate D{sub G} values for different breast thicknesses provided by a Ho logic Selen ia Dimensions system using a DBT mode in comparison with the same results obtained by a calibrated 90 X 5-6M-model Radcal ionization chamber. D{sub G} values were derived from the incident air kerma (K{sub i}) measurements and tabulated conversion coefficients that are dependent on the half value layer (HVL) of the X-ray spectrum. Voltage and tube loading values were recorded in irradiations using W/Al anode/filter combination, automatic exposure control mode and polymethyl methacrylate (PMMA) slabs which simulate different breast thicknesses. For K{sub i} measurements, the ionization chamber was positioned at 655 mm from the focus and the same radiographic technique values were selected with the manual mode. D{sub G} values for a complete procedure ranged from 0.9 ± 0.1 to 3.7 ± 0.4 mGy. The results for different breast thicknesses are in accordance with values obtained by DBT images and with acceptable levels established by the Commission of the European Communities (Cec) and the International Atomic Energy Agency (IAEA

  11. Estimation of glandular content rate and statistical analysis of the influence of age group and compressed breast thickness on the estimated value

    International Nuclear Information System (INIS)

    Ohmori, Naoki; Ashida, Kenji; Fujita, Osamu

    2003-01-01

    Because the glandular content rate is an important factor in evaluating breast cancer detection and average glandular dose, it is important in mammography research to estimate and analyze this rate. The purpose of this study was to obtain a formula for statistical estimation of the glandular content rate, to clarify statistically the influence of age group and compressed breast thickness (CBT) on estimating the glandular content rate, and to show statistically the general relation between glandular content rate and the factors of age and CBT. The subjects were 740 Japanese women aged 20-91 years (mean±SD: 48.3±12.8 years) who had undergone mammography. In our study, the glandular content rate was statistically estimated from age group, mAs-value, and CBT when subjects underwent mammography, from a phantom simulation, and from MR images of the breast. In addition, multivariate analysis was carried to examine statistically the influence of age group and CBT on glandular content rate. The mean glandular content rate as estimated by age group was as follows: 35.6% for those in their 20s, 33.4% in the 30s, 27.5% in the 40s, 23.8% in the 50s, and 21.8% in those 60 and over. The rate for the subjects as a whole was 27.1%. This study indicated that overestimation occurred if the estimated value of the glandular content rate was not corrected in the 3D-measurement by MRI. In addition, this study showed that the statistical influence on glandular content rate was significantly larger for CBT than age. (author)

  12. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients

    International Nuclear Information System (INIS)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-01-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  13. Glandular dose in breast tomosynthesis examinations: Preliminary study with a sample of patients; Dosis glandular en examenes de tomosintesis de mama: estudio preliminar con una muestra de pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Castillo, M.; Chevalier, M.; Calzado, A.; Valverde, J.

    2013-07-01

    The aim of this study is to analyze the mean glandular dose administered to a group of patients with a tomography system (Selenia Dimensions) service installed on a large hospital in which routine tests are done and screening. (Author)

  14. Comparison of average glandular dose in screen-film and digital mammography using breast tissue-equivalent phantom

    International Nuclear Information System (INIS)

    Shin, Gwi Soon; Kim, Jung Min; Kim, You Hyun; Choi, Jong Hak; Kim, Chang Kyun

    2007-01-01

    In recent years, mammography system is changed rapidly from conventional screen-film system to digital system for application to screening and diagnosis. Digital mammography system provides several advantages over screen-film mammography system. According to the information provided by the manufacturer, digital mammography system offers radiation dose reduction in comparison with screen-film mammography system, because of digital detector, particularly direct digital detector has higher x-ray absorption efficiency than screen-film combination or imaging plate (IP). We measured average glandular doses (ADG) in screen-film mammography (SFM) system with slow screen-film combination, computed mammography (CM) system, indirect digital mammography (IDM) system and direct digital mammography (DDM) system using breast tissue-equivalent phantom (glandularity 30%, 50% and 70%). The results were shown as follows: AGD values for DDM system were highest than those for other systems. Although automatic exposure control (AEC) mode was selected, the curve of the AGD values against thickness or glandularity increased significantly for the SFM system with the uniform target/filter (Mo/Mo) combination. Therefore, the AGD values for the high energy examinations were highest in the SFM system, and those for the low energy examinations were highest in the DDM system. But the curve of the AGD values against thickness and glandularity increased gently for CM system with the automatic selection of the target/filter combination (from Mo/Mo to Mo/Rh or from Mo/Rh to Rh/Rh), and the AGD values were lowest. Consequently, the parameters in mammography for each exposure besides detection efficiency play an important role in order to estimate a patient radiation dose

  15. Average glandular dose in paired digital mammography and digital breast tomosynthesis acquisitions in a population based screening program: effects of measuring breast density, air kerma and beam quality

    Science.gov (United States)

    Helge Østerås, Bjørn; Skaane, Per; Gullien, Randi; Catrine Trægde Martinsen, Anne

    2018-02-01

    The main purpose was to compare average glandular dose (AGD) for same-compression digital mammography (DM) and digital breast tomosynthesis (DBT) acquisitions in a population based screening program, with and without breast density stratification, as determined by automatically calculated breast density (Quantra™). Secondary, to compare AGD estimates based on measured breast density, air kerma and half value layer (HVL) to DICOM metadata based estimates. AGD was estimated for 3819 women participating in the screening trial. All received craniocaudal and mediolateral oblique views of each breasts with paired DM and DBT acquisitions. Exposure parameters were extracted from DICOM metadata. Air kerma and HVL were measured for all beam qualities used to acquire the mammograms. Volumetric breast density was estimated using Quantra™. AGD was estimated using the Dance model. AGD reported directly from the DICOM metadata was also assessed. Mean AGD was 1.74 and 2.10 mGy for DM and DBT, respectively. Mean DBT/DM AGD ratio was 1.24. For fatty breasts: mean AGD was 1.74 and 2.27 mGy for DM and DBT, respectively. For dense breasts: mean AGD was 1.73 and 1.79 mGy, for DM and DBT, respectively. For breasts of similar thickness, dense breasts had higher AGD for DM and similar AGD for DBT. The DBT/DM dose ratio was substantially lower for dense compared to fatty breasts (1.08 versus 1.33). The average c-factor was 1.16. Using previously published polynomials to estimate glandularity from thickness underestimated the c-factor by 5.9% on average. Mean AGD error between estimates based on measurements (air kerma and HVL) versus DICOM header data was 3.8%, but for one mammography unit as high as 7.9%. Mean error of using the AGD value reported in the DICOM header was 10.7 and 13.3%, respectively. Thus, measurement of breast density, radiation dose and beam quality can substantially affect AGD estimates.

  16. A comparison of mean glandular dose diagnostic reference levels within the all-digital irish national breast screening programme and the Irish symptomatic breast services

    International Nuclear Information System (INIS)

    O'Leary, D.; Rainford, L.

    2013-01-01

    Data on image quality, compression and radiation dose were collected from symptomatic breast units within the Republic of Ireland. Quantitative and qualitative data were analysed using SPSS. Recommendations of mean glandular dose (MGD) diagnostic reference levels were made at various levels for film-screen and full field digital mammography units to match levels published worldwide. MGDs received by symptomatic breast patients within Ireland are higher than those received in the all-digital Irish Breast Screening service; 55-65 mm breast: 1.75 mGy (screening) vs. 2.4 mGy (symptomatic) at the 95. percentile; various reasons are proposed for the differences. MGDs achieved in the screening service may be lower because of the exacting requirements for radiographer training, characteristics of the patients and equipment quality assurance levels. More precise imaging guidelines, standards and training of symptomatic radiographers performing mammography are suggested to remediate MGDs delivered to the breasts of Irish women attending the symptomatic breast services. (authors)

  17. Distinct Ezrin Truncations Differentiate Metastases in Sentinel Lymph Nodes from Unaffected Lymph Node Tissues, from Primary Breast Tumors, and from Healthy Glandular Breast Tissues

    Directory of Open Access Journals (Sweden)

    Claudia Röwer

    2018-02-01

    Full Text Available BACKGROUND: Lymph node metastasis status is a prognostic factor for further lymph node involvement and for patient survival in breast cancer patients. Frozen section analysis of lymph nodes is a reliable method for detection of macro-metastases. However, this method is far less effective in detecting micro-metastases, requesting improved diagnostic procedures. METHODS: We investigated expression and truncation of ezrin in (i sentinel lymph node metastases, (ii unaffected axillary lymph nodes, (iii primary breast tumors, and (iv healthy glandular breast tissues using 2D gel electrophoresis, SDS-PAGE, and mass spectrometry in addition to Western blotting. RESULTS: Full-length ezrin (E1; amino acids 1–586 is present in all four investigated tissues. Two truncated ezrin forms, one missing about the first hundred amino acids (E2a and the other lacking about 150 C-terminal amino acids (E2b were detectable in primary tumor tissues and in sentinel lymph node metastases but not in glandular tissues. Strikingly, an ezrin truncation (E3 which consists approximately of amino acids 238–586 was found strongly expressed in all sentinel lymph node metastases. Moreover, an N-terminal ezrin fragment (E4 that consists approximately of amino acids 1–273 was identified in sentinel lymph node metastases as well. CONCLUSIONS: We show for the first time the existence of tissue-dependent specific ezrin truncations. The distinguished strong Western blot staining of ezrin E3 in sentinel lymph node metastases underlines its capability to substantiate the occurrence of lymph node (micrometastases in breast cancer patients.

  18. A calibration approach to glandular tissue composition estimation in digital mammography

    International Nuclear Information System (INIS)

    Kaufhold, J.; Thomas, J.A.; Eberhard, J.W.; Galbo, C.E.; Trotter, D.E. Gonzalez

    2002-01-01

    The healthy breast is almost entirely composed of a mixture of fatty, epithelial, and stromal tissues which can be grouped into two distinctly attenuating tissue types: fatty and glandular. Further, the amount of glandular tissue is linked to breast cancer risk, so an objective quantitative analysis of glandular tissue can aid in risk estimation. Highnam and Brady have measured glandular tissue composition objectively. However, they argue that their work should only be used for 'relative' tissue measurements unless a careful calibration has been performed. In this work, we perform such a 'careful calibration' on a digital mammography system and use it to estimate breast tissue composition of patient breasts. We imaged 0%, 50%, and 100% glandular-equivalent phantoms of varying thicknesses for a number of clinically relevant x-ray techniques on a digital mammography system. From these images, we extracted mean signal and noise levels and computed calibration curves that can be used for quantitative tissue composition estimation. In this way, we calculate the percent glandular composition of a patient breast on a pixelwise basis. This tissue composition estimation method was applied to 23 digital mammograms. We estimated the quantitative impact of different error sources on the estimates of tissue composition. These error sources include compressed breast height estimation error, residual scattered radiation, quantum noise, and beam hardening. Errors in the compressed breast height estimate contribute the most error in tissue composition--on the order of ±7% for a 4 cm compressed breast height. The spatially varying scattered radiation will contribute quantitatively less error overall, but may be significant in regions near the skinline. It is calculated that for a 4 cm compressed breast height, a residual scatter signal error is mitigated by approximately sixfold in the composition estimate. The error in composition due to the quantum noise, which is the limiting

  19. Average glandular dose in patients submitted to mammographic examinations

    International Nuclear Information System (INIS)

    Nogueira, M.S.; Silva, T.A. da; Oliveira, M. de; Joana, G.S.; Oliveira, A.L.K.

    2008-01-01

    Doses in mammography should be maintained as low as possible without reducing the high image quality needed to the early detection of the breast cancer. As the breast is composed of tissues with very soft composition and densities, it increases the difficulty to detect small changes in the normal anatomical structures that may be associated with breast cancer. To achieve the standards of resolution and contrast for mammography, the quality and intensity of the X-ray beam, the breast positioning and compression, the film screen system, and the film processing must be in optimal operational conditions. This study intended to evaluate the mean glandular dose of patients undergoing routine exams in one mammography unit. Patient image analyses were done by a radiologist doctor who took into account 10 evaluation criteria for each CC and MLO incidences. For estimating each patient glandular dose the radiographic technique parameters (kV and mAs) and the thickness of the compressed breast were recorded. European image quality criteria were adopted by the radiologist doctor to accept the image for diagnostic purpose. For breast densities of 50% adipose and 50% glandular tissues the incident air-kerma was measured and the glandular dose calculated considering the x-ray output during the exam. In the study of 50 patients the mean glandular dose varied from 0.90 to 3.27 mGy with a mean value of 1.98 mGy for CC incidences. For MLO incidences the mean glandular doses ranged from 0.97 to 3.98 mGy and a mean value of 2.60 mGy. (author)

  20. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Lai, C; Zhong, Y; Wang, T; Shaw, C [UT MD Anderson Cancer Center, Houston, TX (United States)

    2015-06-15

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor.

  1. MO-F-CAMPUS-I-02: Accuracy in Converting the Average Breast Dose Into the Mean Glandular Dose (MGD) Using the F-Factor in Cone Beam Breast CT- a Monte Carlo Study Using Homogeneous and Quasi-Homogeneous Phantoms

    International Nuclear Information System (INIS)

    Lai, C; Zhong, Y; Wang, T; Shaw, C

    2015-01-01

    Purpose: To investigate the accuracy in estimating the mean glandular dose (MGD) for homogeneous breast phantoms by converting from the average breast dose using the F-factor in cone beam breast CT. Methods: EGSnrc-based Monte Carlo codes were used to estimate the MGDs. 13-cm in diameter, 10-cm high hemi-ellipsoids were used to simulate pendant-geometry breasts. Two different types of hemi-ellipsoidal models were employed: voxels in quasi-homogeneous phantoms were designed as either adipose or glandular tissue while voxels in homogeneous phantoms were designed as the mixture of adipose and glandular tissues. Breast compositions of 25% and 50% volume glandular fractions (VGFs), defined as the ratio of glandular tissue voxels to entire breast voxels in the quasi-homogeneous phantoms, were studied. These VGFs were converted into glandular fractions by weight and used to construct the corresponding homogeneous phantoms. 80 kVp x-rays with a mean energy of 47 keV was used in the simulation. A total of 109 photons were used to image the phantoms and the energies deposited in the phantom voxels were tallied. Breast doses in homogeneous phantoms were averaged over all voxels and then used to calculate the MGDs using the F-factors evaluated at the mean energy of the x-rays. The MGDs for quasi-homogeneous phantoms were computed directly by averaging the doses over all glandular tissue voxels. The MGDs estimated for the two types of phantoms were normalized to the free-in-air dose at the iso-center and compared. Results: The normalized MGDs were 0.756 and 0.732 mGy/mGy for the 25% and 50% VGF homogeneous breasts and 0.761 and 0.733 mGy/mGy for the corresponding quasi-homogeneous breasts, respectively. The MGDs estimated for the two types of phantoms were similar within 1% in this study. Conclusion: MGDs for homogeneous breast models may be adequately estimated by converting from the average breast dose using the F-factor

  2. Additional Surgery after Breast-Conserving Surgery Varies Widely

    Science.gov (United States)

    A study published in the Feb. 1, 2012, issue of JAMA found that the number of women who have one or more additional surgeries to remove suspected residual tumor tissue (re-excisions) following breast-conserving surgery (BCS) for breast cancer varies widely across surgeons and hospitals.

  3. Comparative evaluation of average glandular dose and breast cancer detection between single-view digital breast tomosynthesis (DBT) plus single-view digital mammography (DM) and two-view DM: correlation with breast thickness and density

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Ui; Chang, Jung Min; Bae, Min Sun; Lee, Su Hyun; Cho, Nariya; Seo, Mirinae; Kim, Won Hwa; Moon, Woo Kyung [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of)

    2015-01-15

    To compare the average glandular dose (AGD) and diagnostic performance of mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus cranio-caudal (CC) digital mammography (DM) with two-view DM, and to evaluate the correlation of AGD with breast thickness and density. MLO and CC DM and DBT images of both breasts were obtained in 149 subjects. AGDs of DBT and DM per exposure were recorded, and their correlation with breast thickness and density were evaluated. Paired data of MLO DBT plus CC DM and two-view DM were reviewed for presence of malignancy in a jack-knife alternative free-response ROC (JAFROC) method. The AGDs of both DBT and DM, and differences in AGD between DBT and DM (ΔAGD), were correlated with breast thickness and density. The average JAFROC figure of merit (FOM) was significantly higher on the combined technique than two-view DM (P = 0.005). In dense breasts, the FOM and sensitivity of the combined technique was higher than that of two-view DM (P = 0.003) with small ΔAGD. MLO DBT plus CC DM provided higher diagnostic performance than two-view DM in dense breasts with a small increase in AGD. (orig.)

  4. Comparative evaluation of average glandular dose and breast cancer detection between single-view digital breast tomosynthesis (DBT) plus single-view digital mammography (DM) and two-view DM: correlation with breast thickness and density

    International Nuclear Information System (INIS)

    Shin, Sung Ui; Chang, Jung Min; Bae, Min Sun; Lee, Su Hyun; Cho, Nariya; Seo, Mirinae; Kim, Won Hwa; Moon, Woo Kyung

    2015-01-01

    To compare the average glandular dose (AGD) and diagnostic performance of mediolateral oblique (MLO) digital breast tomosynthesis (DBT) plus cranio-caudal (CC) digital mammography (DM) with two-view DM, and to evaluate the correlation of AGD with breast thickness and density. MLO and CC DM and DBT images of both breasts were obtained in 149 subjects. AGDs of DBT and DM per exposure were recorded, and their correlation with breast thickness and density were evaluated. Paired data of MLO DBT plus CC DM and two-view DM were reviewed for presence of malignancy in a jack-knife alternative free-response ROC (JAFROC) method. The AGDs of both DBT and DM, and differences in AGD between DBT and DM (ΔAGD), were correlated with breast thickness and density. The average JAFROC figure of merit (FOM) was significantly higher on the combined technique than two-view DM (P = 0.005). In dense breasts, the FOM and sensitivity of the combined technique was higher than that of two-view DM (P = 0.003) with small ΔAGD. MLO DBT plus CC DM provided higher diagnostic performance than two-view DM in dense breasts with a small increase in AGD. (orig.)

  5. Plant Glandular Trichomes

    Indian Academy of Sciences (India)

    landing on the plant. Glandular trichomes in catmint (Nepeta sp.) produce nepetalactone, closely related to the aphid sex pheromone, nepetalactol. Nepetalactone can be reduced to the corresponding nepetalactol. ... Plant glandular trichomes function either as repositories or releasing sites of various chemicals. Interest in ...

  6. Dual-energy digital mammography: Calibration and inverse-mapping techniques to estimate calcification thickness and glandular-tissue ratio

    International Nuclear Information System (INIS)

    Kappadath, S. Cheenu; Shaw, Chris C.

    2003-01-01

    Breast cancer may manifest as microcalcifications in x-ray mammography. Small microcalcifications, essential to the early detection of breast cancer, are often obscured by overlapping tissue structures. Dual-energy imaging, where separate low- and high-energy images are acquired and synthesized to cancel the tissue structures, may improve the ability to detect and visualize microcalcifications. Transmission measurements at two different kVp values were made on breast-tissue-equivalent materials under narrow-beam geometry using an indirect flat-panel mammographic imager. The imaging scenario consisted of variable aluminum thickness (to simulate calcifications) and variable glandular ratio (defined as the ratio of the glandular-tissue thickness to the total tissue thickness) for a fixed total tissue thickness--the clinical situation of microcalcification imaging with varying tissue composition under breast compression. The coefficients of the inverse-mapping functions used to determine material composition from dual-energy measurements were calculated by a least-squares analysis. The linear function poorly modeled both the aluminum thickness and the glandular ratio. The inverse-mapping functions were found to vary as analytic functions of second (conic) or third (cubic) order. By comparing the model predictions with the calibration values, the root-mean-square residuals for both the cubic and the conic functions were ∼50 μm for the aluminum thickness and ∼0.05 for the glandular ratio

  7. Immunohistochemical characterization of glandular elements in glandular cardiac myxoma: Study of six cases

    Directory of Open Access Journals (Sweden)

    Devajit Nath

    2017-01-01

    Full Text Available Back ground: Glandular cardiac myxoma has varying clinical presentation with uncertain histogenesis and debatable immunohistochemical profile. Glandular epithelial differentiations are rare phenomenon known to be present as an intrinsic component of the tumor. The origin of the glands has been attributed to epithelial differentiation of a totipotent cardiomyogenic precursor cells or the entrapped foregut rests in the tumor. Materials and Methods: Retrospective study includes six cases of glandular cardiac myxoma collected over a perior of 4 years. Sections were examined to define the histogenesis, histological and immunohistochemical profile of the glandular elements. Results: Incidence of glandular cardiac myxoma was 6.6% with a male to female ratio of 1:2.Mean age was 49.9 years. Left atrium was the commonest site. Five were sporadic and one was familial. Chest pain and dyspnea were the commonest clinical symptoms. Histologically all myxoma showed well formed glandular structures with typical myxomatous area. No atypia, mitosis or necrosis was identified in the glandular elements. Markers in six cases of glandular cardiac myxoma were immunopositive for CK7, CK 19, EMA, CEA, focally for E-cadherin while immunonegative for CK20, Chromogranin, Synaptophysin, calretenin, vimentin, B-catenin, TTF-1 and GCDFP-15 favoring enteric differentiation. Conclusion: Glandular cardiac myxoma is a rare entity which shows characteristics similar to those of classical cardiac myxoma with benign glandular elements showing enteric differentiation. Complete surgical excision is the treatment of choice with good prognosis. It is important to recognize this entity to avoid an erroneous diagnosis of metastatic adenocarcinoma.

  8. Assessment of Mean Glandular Dose in Mammography System with Different Anode-Filter Combinations Using MCNP Code.

    Science.gov (United States)

    Gholamkar, Lida; Mowlavi, Ali Asghar; Sadeghi, Mahdi; Athari, Mitra

    2016-10-01

    X-ray mammography is one of the general methods for early detection of breast cancer. Since glandular tissue in the breast is sensitive to radiation and it increases the risk of cancer, the given dose to the patient is very important in mammography. The aim of this study was to determine the average absorbed dose of X-ray radiation in the glandular tissue of the breast during mammography examinations as well as investigating factors that influence the mean glandular dose (MGD). One of the precise methods for determination of MGD absorbed by the breast is Monte Carlo simulation method which is widely used to assess the dose. We studied some different X-ray sources and exposure factors that affect the MGD. "Midi-future" digital mammography system with amorphous-selenium detector was simulated using the Monte Carlo N-particle extended (MCNPX) code. Different anode/filter combinations such as tungsten/silver (W/Ag), tungsten/rhodium (W/Rh), and rhodium/aluminium (Rh/Al) were simulated in this study. The voltage of X-ray tube ranged from 24 kV to 32 kV with 2 kV intervals and the breast phantom thickness ranged from 3 to 8 cm, and glandular fraction g varied from 10% to 100%. MGD was measured for different anode/filter combinations and the effects of changing tube voltage, phantom thickness, combination and glandular breast tissue on MGD were studied. As glandular g and X-ray tube voltage increased, the breast dose increased too, and the increase of breast phantom thickness led to the decrease of MGD. The obtained results for MGD were consistent with the result of Boone et al. that was previously reported. By comparing the results, we saw that W/Rh anode/filter combination is the best choice in breast mammography imaging because of the lowest delivered dose in comparison with W/Ag and Rh/Al. Moreover, breast thickness and g value have significant effects on MGD.

  9. A Monte Carlo model for mean glandular dose evaluation in spot compression mammography.

    Science.gov (United States)

    Sarno, Antonio; Dance, David R; van Engen, Ruben E; Young, Kenneth C; Russo, Paolo; Di Lillo, Francesca; Mettivier, Giovanni; Bliznakova, Kristina; Fei, Baowei; Sechopoulos, Ioannis

    2017-07-01

    To characterize the dependence of normalized glandular dose (DgN) on various breast model and image acquisition parameters during spot compression mammography and other partial breast irradiation conditions, and evaluate alternative previously proposed dose-related metrics for this breast imaging modality. Using Monte Carlo simulations with both simple homogeneous breast models and patient-specific breasts, three different dose-related metrics for spot compression mammography were compared: the standard DgN, the normalized glandular dose to only the directly irradiated portion of the breast (DgNv), and the DgN obtained by the product of the DgN for full field irradiation and the ratio of the mid-height area of the irradiated breast to the entire breast area (DgN M ). How these metrics vary with field-of-view size, spot area thickness, x-ray energy, spot area and position, breast shape and size, and system geometry was characterized for the simple breast model and a comparison of the simple model results to those with patient-specific breasts was also performed. The DgN in spot compression mammography can vary considerably with breast area. However, the difference in breast thickness between the spot compressed area and the uncompressed area does not introduce a variation in DgN. As long as the spot compressed area is completely within the breast area and only the compressed breast portion is directly irradiated, its position and size does not introduce a variation in DgN for the homogeneous breast model. As expected, DgN is lower than DgNv for all partial breast irradiation areas, especially when considering spot compression areas within the clinically used range. DgN M underestimates DgN by 6.7% for a W/Rh spectrum at 28 kVp and for a 9 × 9 cm 2 compression paddle. As part of the development of a new breast dosimetry model, a task undertaken by the American Association of Physicists in Medicine and the European Federation of Organizations of Medical Physics

  10. The study of mean glandular dose in mammography in Yazd and the factors affecting it

    International Nuclear Information System (INIS)

    Bouzarjomehri, F.; Mostaar, A.; Ghasemi, A.; Ehramposh, M. H.; Khosravi, H.

    2006-01-01

    The objective of this study was to determine the mean glandular dose resulting from mammography examinations in Yazd, southeastern Iran and to identify the factors affecting it. Patients and Methods: This survey was conducted during May to December 2005 to estimate the mean glandular dose for women undergoing mammography and to report the distribution of dose. compressed breast thickness, glandular tissue content, and mammography technique used. The clinical data were collected from 946 mammograms taken from 246 women who were referred to four mammography centers. The mammography instruments in these centers were four modern units with a molybdenum anode and either molybdenum or rhodium filter. The exposure conditions of each mammogram were recorded. The breast glandular content of each mammogram was estimated by a radiologist. The mean glandular dose was calculated based on measuring the normalized entrance skin dose in air. half value layer, kVp, mAs, breast thickness and glandular content. Half value layer, kVp and entrance skin dose were measured by a solid-state detector. The analytical method of Sobol et al. was used for calculation of mean glandular dose . Results: The mean±SD mean glandular dose per film was.2±0.6 mGy for cranio caudal and 1.63±O.9 mGy for mediolateral oblique views. The mean±SD mean glandular dose per woman was 5.5 3.1.mGy. A positive correlation was found between the beam Half value layer with mean glandular dose (r=O.38) and the breast thickness with mean glandular dose (r=O.5). Conclusion: The mean±SD mean glandular dose per film of 1.42±0.8 mGy in present study was lower than most of similar reports. However, the mean mean glandular dose per woman was higher than that in other studies

  11. Evaluation of glandular dose in conventional and digital mammography systems

    International Nuclear Information System (INIS)

    Coutinho, Celia Maria Campos

    2009-01-01

    A survey was conducted to estimate the average glandular dose (D g ) for patients undergoing mammography and to report the distribution of incident air kerma (K i ), patient age, compressed breast thickness and glandular tissue content. From 1183 cranio caudal mammograms clinical data were collected and doses were measured. The survey data included mammograms from six mammography equipment: two screen/film units (SFM), two computed radiography units (CR) and two full-field digital (DR). Mean value for patient age and compressed breast thickness were 57 +-12 y and 5.4 +-1.4 cm, respectively. To investigate the importance of technical characteristics of three different mammography systems and breast glandularity, K i and D g were measured for individual breast of 392 patients from the original sample with compressed breast thickness in the range of 5.5 cm to 6.5 cm using tissue-equivalent phantoms of different glandularities manufactured in this study to mimic both the attenuation and the density of breast tissues. Mean K i value was 10.0 +-3.6 mGy for SFM systems, 12.0 +-3.6 mGy for CR systems and 4.9 +-1.3 mGy for DR systems. Mean D g value was 1.4 +-0.5 mGy for S/F systems, 1.7 +-0.5 mGy for CR systems and 0.9 +-0.2 mGy for D R systems. Statistical analysis for differences in mean values of K i and D g between mammography systems showed significant effect of their technical characteristics (p i and D g , it was observed statistically significant differences between the group of patients with 0 to 50% glandularity and the group of patients with 50 to 100% glandularity. (author)

  12. FORTRAN Code for Glandular Dose Calculation in Mammography Using Sobol-Wu Parameters

    Directory of Open Access Journals (Sweden)

    Mowlavi A A

    2007-07-01

    Full Text Available Background: Accurate computation of the radiation dose to the breast is essential to mammography. Various the thicknesses of breast, the composition of the breast tissue and other variables affect the optimal breast dose. Furthermore, the glandular fraction, which refers to the composition of the breasts, as partitioned between radiation-sensitive glandular tissue and the adipose tissue, also has an effect on this calculation. Fatty or fibrous breasts would have a lower value for the glandular fraction than dense breasts. Breast tissue composed of half glandular and half adipose tissue would have a glandular fraction in between that of fatty and dense breasts. Therefore, the use of a computational code for average glandular dose calculation in mammography is a more effective means of estimating the dose of radiation, and is accurate and fast. Methods: In the present work, the Sobol-Wu beam quality parameters are used to write a FORTRAN code for glandular dose calculation in molybdenum anode-molybdenum filter (Mo-Mo, molybdenum anode-rhodium filter (Mo-Rh and rhodium anode-rhodium filter (Rh-Rh target-filter combinations in mammograms. The input parameters of code are: tube voltage in kV, half-value layer (HVL of the incident x-ray spectrum in mm, breast thickness in cm (d, and glandular tissue fraction (g. Results: The average glandular dose (AGD variation against the voltage of the mammogram X-ray tube for d = 4 cm, HVL = 0.34 mm Al and g=0.5 for the three filter-target combinations, as well as its variation against the glandular fraction of breast tissue for kV=25, HVL=0.34, and d=4 cm has been calculated. The results related to the average glandular absorbed dose variation against HVL for kV = 28, d=4 cm and g= 0.6 are also presented. The results of this code are in good agreement with those previously reported in the literature. Conclusion: The code developed in this study calculates the glandular dose quickly, and it is complete and

  13. TU-H-CAMPUS-JeP2-01: Inter-Observer Delineation Comparison of Visible Glandular Breast Tissue On Magnetic Resonance Imaging and Computed Tomography (prone and Supine)

    International Nuclear Information System (INIS)

    Pogson, EM; Delaney, G; Yap, M; Ahern, V; Boxer, M; David, S; Dimigen, M; Harvey, J; Koh, E; Batumalai, V; Lim, K; Papadatos, G; Metcalfe, P

    2016-01-01

    Purpose: Breast cancers predominantly arise from Glandular Breast Tissue (GBT). If the GBT can be treated effectively post-operatively utilising radiotherapy this may be adequate volumetric coverage for adjuvant breast radiotherapy. Adequate imaging of the GBT is necessary and will be assessed between MRI and CT modalities. GBT visualisation is acknowledged to be qualitatively superior on Magnetic Resonance Image (MRI) compared to Computed Tomography (CT), the current radiotherapy imaging standard, however this has not been quantitatively assessed. For radiotherapy purposes it is important that any treatment volume can be consistently defined between observers. This study investigates the consistency of CT and MRI GBT contours for potential radiotherapy planning. Methods: Ten experts (9 breast radiation oncologists and 1 radiologist) contoured the extent of the visible GBT for 33 patients on MRI and CT (both without contrast), which was performed according to a contouring guideline in supine and prone patient positions. The GBT volume was not a conventional whole breast radiotherapy planning volume, but rather the extent of GBT that was indicated from the CT or MR imaging. Volumes were compared utilizing the dice similarity coefficient (DSC), kappa statistic, and Hausdorff Distances (HDs) to ascertain the modality that was most consistently volumed. Results: The inter-observer concordance was of substantial agreement (kappa above 0.6) for the CT supine, CT prone, MRI supine and MRI prone datasets. The MRI GBT volumes were larger than the CT GBT volumes (p<0.001). Inter-observer conformity was higher for CT than MRI, although the magnitude of this difference was small (VOI<0.04). Conformity between modalities (CT and MRI) was in agreement for both prone and supine, DSC=0.75. Prone GBT volumes were larger than supine for both MRI and CT. Conclusion: MRI improves the extent of GBT delineation. The role of MRI guided, GBT-targeted radiotherapy requires investigation in

  14. TU-H-CAMPUS-JeP2-01: Inter-Observer Delineation Comparison of Visible Glandular Breast Tissue On Magnetic Resonance Imaging and Computed Tomography (prone and Supine)

    Energy Technology Data Exchange (ETDEWEB)

    Pogson, EM [Institute of Medical Physics, University of Sydney, Sydney, NSW (Australia); University of Wollongong, Wollongong, NSW (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); Delaney, G; Yap, M [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney, NSW (Australia); School of Medicine, University of Western Sydney, Sydney, NSW (Australia); Ahern, V [Westmead Hospital, Westmead, NSW (Australia); Boxer, M [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); David, S [Peter MacCallum Cancer Institute,, Melbourne, VIC (Australia); Dimigen, M [Department of Radiology, Liverpool Hospital, NSW (United Kingdom); Harvey, J [University of Queensland, Brisbane, QLD (Australia); Princess Alexandra Hospital, QLD (Australia); Koh, E; Batumalai, V [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); South Western Sydney Clinical School, University of New South Wales, Sydney, NSW (Australia); Lim, K; Papadatos, G [Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Metcalfe, P [University of Wollongong, Wollongong, NSW (Australia); Liverpool and Macarthur Cancer Therapy Centres, Liverpool, NSW (United Kingdom); Ingham Institute for Applied Medical Research, Liverpool Hospital, Sydney, NSW (Australia); and others

    2016-06-15

    Purpose: Breast cancers predominantly arise from Glandular Breast Tissue (GBT). If the GBT can be treated effectively post-operatively utilising radiotherapy this may be adequate volumetric coverage for adjuvant breast radiotherapy. Adequate imaging of the GBT is necessary and will be assessed between MRI and CT modalities. GBT visualisation is acknowledged to be qualitatively superior on Magnetic Resonance Image (MRI) compared to Computed Tomography (CT), the current radiotherapy imaging standard, however this has not been quantitatively assessed. For radiotherapy purposes it is important that any treatment volume can be consistently defined between observers. This study investigates the consistency of CT and MRI GBT contours for potential radiotherapy planning. Methods: Ten experts (9 breast radiation oncologists and 1 radiologist) contoured the extent of the visible GBT for 33 patients on MRI and CT (both without contrast), which was performed according to a contouring guideline in supine and prone patient positions. The GBT volume was not a conventional whole breast radiotherapy planning volume, but rather the extent of GBT that was indicated from the CT or MR imaging. Volumes were compared utilizing the dice similarity coefficient (DSC), kappa statistic, and Hausdorff Distances (HDs) to ascertain the modality that was most consistently volumed. Results: The inter-observer concordance was of substantial agreement (kappa above 0.6) for the CT supine, CT prone, MRI supine and MRI prone datasets. The MRI GBT volumes were larger than the CT GBT volumes (p<0.001). Inter-observer conformity was higher for CT than MRI, although the magnitude of this difference was small (VOI<0.04). Conformity between modalities (CT and MRI) was in agreement for both prone and supine, DSC=0.75. Prone GBT volumes were larger than supine for both MRI and CT. Conclusion: MRI improves the extent of GBT delineation. The role of MRI guided, GBT-targeted radiotherapy requires investigation in

  15. Dense Breasts: Answers to Commonly Asked Questions

    Science.gov (United States)

    ... Cancer Prevention Genetics of Breast & Gynecologic Cancers Breast Cancer Screening Research Dense Breasts: Answers to Commonly Asked Questions What are dense breasts? Breasts contain glandular, connective, and fat tissue. Breast density is a term that describes the ...

  16. Reduced risk of breast cancer associated with recreational physical activity varies by HER2 status

    International Nuclear Information System (INIS)

    Ma, Huiyan; Xu, Xinxin; Ursin, Giske; Simon, Michael S; Marchbanks, Polly A; Malone, Kathleen E; Lu, Yani; McDonald, Jill A; Folger, Suzanne G; Weiss, Linda K; Sullivan-Halley, Jane; Deapen, Dennis M; Press, Michael F; Bernstein, Leslie

    2015-01-01

    Convincing epidemiologic evidence indicates that physical activity is inversely associated with breast cancer risk. Whether this association varies by the tumor protein expression status of the estrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor receptor 2 (HER2), or p53 is unclear. We evaluated the effects of recreational physical activity on risk of invasive breast cancer classified by the four biomarkers, fitting multivariable unconditional logistic regression models to data from 1195 case and 2012 control participants in the population-based Women’s Contraceptive and Reproductive Experiences Study. Self-reported recreational physical activity at different life periods was measured as average annual metabolic equivalents of energy expenditure [MET]-hours per week. Our biomarker-specific analyses showed that lifetime recreational physical activity was negatively associated with the risks of ER-positive (ER+) and of HER2-negative (HER2−) subtypes (both P trend ≤ 0.04), but not with other subtypes (all P trend > 0.10). Analyses using combinations of biomarkers indicated that risk of invasive breast cancer varied only by HER2 status. Risk of HER2–breast cancer decreased with increasing number of MET-hours of recreational physical activity in each specific life period examined, although some trend tests were only marginally statistically significant (all P trend ≤ 0.06). The test for homogeneity of trends (HER2– vs. HER2+) reached statistical significance only when evaluating physical activity during the first 10 years after menarche (P homogeneity = 0.03). Our data suggest that physical activity reduces risk of invasive breast cancers that lack HER2 overexpression, increasing our understanding of the biological mechanisms by which physical activity acts

  17. Dedicated breast CT: radiation dose for circle-plus-line trajectory

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; Noo, Frederic

    2012-01-01

    Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD g N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD g N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD g N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2π for the circular scan, the addition of a line trajectory with equal

  18. TU-F-18C-05: Evaluation of a Method to Calculate Patient-Oriented MGD Coefficients Using Estimates of Glandular Tissue Distribution

    International Nuclear Information System (INIS)

    Porras-Chaverri, M; Galavis, P; Bakic, P; Vetter, J

    2014-01-01

    Purpose: Evaluate mammographic mean glandular dose (MGD) coefficients for particular known tissue distributions using a novel formalism that incorporates the effect of the heterogeneous glandular tissue distribution, by comparing them with MGD coefficients derived from the corresponding anthropomorphic computer breast phantom. Methods: MGD coefficients were obtained using MCNP5 simulations with the currently used homogeneous assumption and the heterogeneously-layered breast (HLB) geometry and compared against those from the computer phantom (ground truth). The tissue distribution for the HLB geometry was estimated using glandularity map image pairs corrected for the presence of non-glandular fibrous tissue. Heterogeneity of tissue distribution was quantified using the glandular tissue distribution index, Idist. The phantom had 5 cm compressed breast thickness (MLO and CC views) and 29% whole breast glandular percentage. Results: Differences as high as 116% were found between the MGD coefficients with the homogeneous breast core assumption and those from the corresponding ground truth. Higher differences were found for cases with more heterogeneous distribution of glandular tissue. The Idist for all cases was in the [−0.8 − +0.3] range. The use of the methods presented in this work results in better agreement with ground truth with an improvement as high as 105 pp. The decrease in difference across all phantom cases was in the [9 − 105] pp range, dependent on the distribution of glandular tissue and was larger for the cases with the highest Idist values. Conclusion: Our results suggest that the use of corrected glandularity image pairs, as well as the HLB geometry, improves the estimates of MGD conversion coefficients by accounting for the distribution of glandular tissue within the breast. The accuracy of this approach with respect to ground truth is highly dependent on the particular glandular tissue distribution studied. Predrag Bakic discloses current

  19. Evaluation of average glandular dose in mammography services in 10 cities of Colombia; Avaliacao de dose glandular media em servicos de mamografia de 10 cidades de Colombia

    Energy Technology Data Exchange (ETDEWEB)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D. [Grupo de Prevencion Temprana Del Cancer, Instituto Nacional de Cancerologia, Bogota D.C. (Colombia)

    2016-07-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  20. Development of an excel spreadsheet formean glandular dose in mammography

    International Nuclear Information System (INIS)

    Nagoshi, Kazuyo; Fujisaki, Tatsuya

    2008-01-01

    The purpose of this study was to develop an Excel spreadsheet to calculate mean glandular dose (D g ) in mammography using clinical exposure data. D g can be calculated as the product of incident air kerma (K a ) and D gN (i.e., D g =K a x D gN ). According to the method of Klein et al (Phys Med Biol 1997; 42: 651-671), K a was measured at the entrance surface with an ionization dosimeter. Normalized glandular dose (D gN ) coefficients, taking into account breast glandularity, were computed using Boone's method (Med Phys 2002; 29: 869-875). D gN coefficients can be calculated for any arbitrary X-ray spectrum. These calculation procedures were input into a Microsoft Excel spreadsheet. The resulting Excel spreadsheet is easy to use and is always applicable in the field of mammography. The exposure conditions concerning D g in clinical practice were also investigated in 22 women. Four exposure conditions (target/filter combination and tube voltage) were automatically selected in this study. This investigation found that average D g for each exposure was 1.9 mGy. Because it is recommended that quality control of radiation dose management in mammography is done using an American College of Radiology (ACR) phantom, information about patient dose is not obtained in many facilities. The present Excel spreadsheet was accordingly considered useful for optimization of exposure conditions and explanation of mammography to patients. (author)

  1. The effect of aluminium added filter on mean glandular dose using mammography machine in MINT Medical Physics Laboratory

    International Nuclear Information System (INIS)

    Asmaliza Hashim; Wan Hazlinda Ismail; Abd Aziz Mhd Ramli

    2005-01-01

    The effect of various thickness of aluminium added filter on mean glandular dose in mammography is investigated for a standard breast phantom, 4.2 cm Perspex. A mammography machine in Medical Physics Laboratory MINT, Bennett Model DMF-150 is used to provide radiation in various kV range under clinical condition. The mean glandular dose on the phantom were measured based on technique recommended by AAPM protocol (1990) report no 29. The mean glandular dose was found reducing with increasing thickness of added filter. A more detail results of this study is presented in this paper. (Author)

  2. Evaluation of average glandular dose in mammography services in 10 cities of Colombia

    International Nuclear Information System (INIS)

    Alejo-Martinez, H.; Salazar-Hurtado, E.; Puerto-Jimenez, D.

    2016-01-01

    The objective of this study was to conduct an assessment of dose in 60 mammography services that have screening programs for breast cancer in 10 cities of Colombia. The third quartile of the average glandular dose was 2,29 mGy, range between 1,0 and 5,6 mGy, for the phantom equivalent to a standard breast. This study included mammography units with conventional and digital technology. (author)

  3. Evaluation of subject contrast and normalized average glandular dose by semi-analytical models

    International Nuclear Information System (INIS)

    Tomal, A.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    In this work, two semi-analytical models are described to evaluate the subject contrast of nodules and the normalized average glandular dose in mammography. Both models were used to study the influence of some parameters, such as breast characteristics (thickness and composition) and incident spectra (kVp and target-filter combination) on the subject contrast of a nodule and on the normalized average glandular dose. From the subject contrast results, detection limits of nodules were also determined. Our results are in good agreement with those reported by other authors, who had used Monte Carlo simulation, showing the robustness of our semi-analytical method.

  4. Method for the evaluation of a average glandular dose in mammography

    International Nuclear Information System (INIS)

    Okunade, Akintunde Akangbe

    2006-01-01

    This paper concerns a method for accurate evaluation of average glandular dose (AGD) in mammography. At different energies, the interactions of photons with tissue are not uniform. Thus, optimal accuracy in the estimation of AGD is achievable when the evaluation is carried out using the normalized glandular dose values, g(x,E), that are determined for each (monoenergetic) x-ray photon energy, E, compressed breast thickness (CBT), x, breast glandular composition, and data on photon energy distribution of the exact x-ray beam used in breast imaging. A generalized model for the values of g(x,E) that is for any arbitrary CBT ranging from 2 to 9 cm (with values that are not whole numbers inclusive, say, 4.2 cm) was developed. Along with other dosimetry formulations, this was integrated into a computer software program, GDOSE.FOR, that was developed for the evaluation of AGD received from any x-ray tube/equipment (irrespective of target-filter combination) of up to 50 kVp. Results are presented which show that the implementation of GDOSE.FOR yields values of normalized glandular dose that are in good agreement with values obtained from methodologies reported earlier in the literature. With the availability of a portable device for real-time acquisition of spectra, the model and computer software reported in this work provide for the routine evaluation of AGD received by a specific woman of known age and CBT

  5. Influence of breast composition and interseed attenuation in dose calculations for post-implant assessment of permanent breast 103Pd seed implant

    International Nuclear Information System (INIS)

    Afsharpour, Hossein; Beaulieu, Luc; Pignol, Jean-Philippe; Keller, Brian; Carrier, Jean-Francois; Reniers, Brigitte; Verhaegen, Frank

    2010-01-01

    The impact of tissue heterogeneity and interseed attenuation is studied in post-implant evaluation of five clinical permanent breast 103 Pd seed implants using the Monte Carlo (MC) dose calculation method. Dose metrics for the target (PTV) as well as an organ at risk (skin) are used to visualize the differences between a TG43-like MC method and more accurate MC methods capable of considering the breast tissue heterogeneity as well as the interseed attenuation. PTV dose is reduced when using a breast tissue model instead of water in MC calculations while the dose to the skin is increased. Furthermore, we investigate the effect of varying the glandular/adipose proportion of the breast tissue on dose distributions. The dose to the PTV (skin) decreases (increases) with the increasing adipose proportion inside the breast. In a complete geometry and compared to a TG43-like situation, the average PTV D 90 reduction varies from 3.9% in a glandular breast to 35.5% when the breast consists entirely of adipose. The skin D 10 increases by 28.2% in an entirely adipose breast. The results of this work show the importance of an accurate and patient-dependent breast tissue model to be used in the dosimetry for this kind of low energy implant.

  6. Calculation of Absorbed Glandular Dose using a FORTRAN Program Based on Monte Carlo X-ray Spectra in Mammography

    Directory of Open Access Journals (Sweden)

    Ali Asghar Mowlavi

    2011-03-01

    Full Text Available Introduction: Average glandular dose calculation in mammography with Mo-Rh target-filter and dose calculation for different situations is accurate and fast. Material and Methods: In this research, first of all, x-ray spectra of a Mo target bombarded by a 28 keV electron beam with and without a Rh filter were calculated using the MCNP code. Then, we used the Sobol-Wu parameters to write a FORTRAN code to calculate average glandular dose. Results: Average glandular dose variation was calculated against the voltage of the mammographic x-ray tube for d = 5 cm, HVL= 0.35 mm Al, and different value of g. Also, the results related to average glandular absorbed dose variation per unit roentgen radiation against the glandular fraction of breast tissue for kV = 28 and HVL = 0.400 mmAl and different values of d are presented. Finally, average glandular dose against d for g = 60% and three values of kV (23, 27, 35 kV with corresponding HVLs have been calculated. Discussion and Conclusion: The absorbed dose computational program is accurate, complete, fast and user friendly. This program can be used for optimization of exposure dose in mammography. Also, the results of this research are in good agreement with the computational results of others.

  7. The association between socioeconomic factors and breast cancer-specific survival varies by race.

    Directory of Open Access Journals (Sweden)

    Shailesh Agarwal

    Full Text Available Although racial disparity is well described for oncologic outcomes, factors associated with survival within racial groups remains unexplored. The objective of this study is to determine whether breast cancer survival among White or Black patients is associated with differing patient factors. Women diagnosed with breast cancer from 1998 through 2012 were identified in the Surveillance, Epidemiology, and End Results (SEER database. Cox proportional hazard logistic regression was used to estimate cause-specific survival in the combined cohort, and separate cohorts of Black or White patients only. Main outcomes included cause-specific survival in cohorts of Black only, White only, or all patients adjusted for demographic and oncologic factors. A total of 406,907 Black (10.8% or White (89.2% patients diagnosed with breast cancer from 1998 through 2012 were isolated. Cancer-specific survival analysis of the combined cohort showed significantly decreased hazard ratio (H.R. in patients from the higher economic quartiles (Q1: 1.0 (ref, Q2: 0.95 (p<0.01, Q3: 0.94 (p<0.01, Q4: 0.87 (p<0.001. Analysis of the White only cohort showed a similar relationship with income (Q1: 1.0 (ref, Q2: 0.95 (p<0.01, Q3: 0.95 (p<0.01, Q4: 0.86 (p<0.001. However, analysis of the Black only cohort did not show a relationship with income (Q1: 1.0 (ref, Q2: 1.04 (p = 0.34, Q3: 0.97 (p = 0.53, Q4: 1.04 (p = 0.47. A test of interaction confirmed that the association between income and cancer-specific survival is dependent on patient race, both with and without adjustment for demographic and oncologic characteristics (p<0.01. While median county income is positively associated with cancer-specific survival among White patients, this is not the case with Black patients. Similar findings were noted for education level. These findings suggest that the association between socioeconomic status and breast cancer survival commonly reported in the literature is specific to White patients

  8. Endocrine determinants of breast density and breast cancer

    NARCIS (Netherlands)

    Verheus, M.

    2007-01-01

    Worldwide, breast cancer is the most common malignancy among females. The total breast area on a mammogram can be dived in a radiologicaly dense area (glandular and stromal tissue) and a non-dense area (mainly fat tissue). Women with a high proportion of dense breast tissue (percent breast density)

  9. Maxilary glandular odontogenic cyst: case report = Cisto odontogênico glandular em maxila: relato de caso

    Directory of Open Access Journals (Sweden)

    Cardoso, Juliana Andrade

    2015-01-01

    Full Text Available Objetivo: O presente trabalho objetiva relatar um caso clínico de cisto odontogênico glandular (COG em maxila, cisto de desenvolvimento raro que pode apresentar comportamento agressivo e recidivante, dando ênfase no tratamento e proservação desta doença. Relato de Caso: Paciente faioderma, gênero feminino, 36 anos, foi encaminhada pelo Ortodontista por apresentar aumento de volume em maxila com abaulamento e crepitação. Foram realizadas radiografias e punção aspirativa. Uma vez observado o conteúdo da lesão, foi realizada a biópsia incisional e iniciada a descompressão com colocação de dreno rígido. Tendo a confirmação do diagnóstico para COG, a paciente foi submetida à cirurgia para remoção do cisto maxilar, através da enucleação cirúrgica, curetagem e osteotomia periférica. Conclusões: O COG é uma patologia incomum, recentemente reconhecida, cujo comportamento biológico pouco ainda se sabe. Sugere-se, portanto, a realização de investigações futuras sobre critérios para classificação de variáveis comumente utilizadas em estudos epidemiológicos, na tentativa de padronizar e possibilitar comparação entre estudos, todavia, para auxiliar em um diagnóstico bem sucedido

  10. Monte Carlo simulation studies for the determination of microcalcification thickness and glandular ratio through dual-energy mammography

    Science.gov (United States)

    Del Lama, L. S.; Godeli, J.; Poletti, M. E.

    2017-08-01

    The majority of breast carcinomas can be associated to the presence of calcifications before the development of a mass. However, the overlapping tissues can obscure the visualization of microcalcification clusters due to the reduced contrast-noise ratio (CNR). In order to overcome this complication, one potential solution is the use of the dual-energy (DE) technique, in which two different images are acquired at low (LE) and high (HE) energies or kVp to highlight specific lesions or cancel out tissue background. In this work, the DE features were computationally studied considering simulated acquisitions from a modified PENELOPE Monte Carlo code. The employed irradiation geometry considered typical distances used in digital mammography, a CsI detection system and an updated breast model composed of skin, microcalcifications and glandular and adipose tissues. The breast thickness ranged from 2 to 6 cm with glandularities of 25%, 50% and 75%, where microcalcifications with dimensions from 100 up to 600 μm were positioned. In general, results pointed an efficiency index better than 87% for the microcalcification thicknesses and better than 95% for the glandular ratio. The simulations evaluated in this work can be used to optimize the elements from the DE imaging chain, in order to become a complementary tool for the conventional single-exposure images, especially for the visualization and estimation of calcification thicknesses and glandular ratios.

  11. Assessment of mean glandular dose to patients from digital mammography systems

    International Nuclear Information System (INIS)

    Pwamang, Caroline K.

    2016-07-01

    Mean glandular dose assessment of patients undergoing digital mammography examination has been done. A total of 297 patient data was used for the study. Basic Quality Control tests were done to ascertain the performance of the equipment used. The results of Quality Control tests indicated that the three Mammography units used for this study were functioning within the internationally acceptable performance criteria. Patients with a breast thickness of 30 mm within the two age groups of 40-49 yrs and 50-64 yrs received doses slightly higher than the acceptable dose levels. A patient in the category 40-49 yrs with breast thickness of 30 mm received 1.83 mGy as calculated Mean Glandular Dose, 2.10 mGy was the recorded dose and 1.58 mGy was recorded under the age group 50-64 yrs. These values have deviated by -22%, -40%, and -5.33% respectively from 1.5 mGy which is the recommended dose for a breast thickness of 30 mm. Also patients with breast thickness of 70 mm under the age group 40–49 yrs had a recorded dose of 6.58 mGy, which deviated by -1.21% from the recommended value of 6.5 mGy for that breast thickness. Aside these values, all the other values were within the recommended dose values. The percentage deviation between the recommended values and the calculated values was within ±25% which was a working limit that was set for this work. Doses delivered by the Full-field Digital mammography equipment were higher than doses delivered by the Computered Radiography equipment. The calculated Mean Glandular Doses for the three facilities were within recommended dose values. (author)

  12. Scatter radiation in digital tomosynthesis of the breast

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Suryanarayanan, Sankararaman; Vedantham, Srinivasan; D'Orsi, Carl J.; Karellas, Andrew

    2007-01-01

    Digital tomosynthesis of the breast is being investigated as one possible solution to the problem of tissue superposition present in planar mammography. This imaging technique presents various advantages that would make it a feasible replacement for planar mammography, among them similar, if not lower, radiation glandular dose to the breast; implementation on conventional digital mammography technology via relatively simple modifications; and fast acquisition time. One significant problem that tomosynthesis of the breast must overcome, however, is the reduction of x-ray scatter inclusion in the projection images. In tomosynthesis, due to the projection geometry and radiation dose considerations, the use of an antiscatter grid presents several challenges. Therefore, the use of postacquisition software-based scatter reduction algorithms seems well justified, requiring a comprehensive evaluation of x-ray scatter content in the tomosynthesis projections. This study aims to gain insight into the behavior of x-ray scatter in tomosynthesis by characterizing the scatter point spread functions (PSFs) and the scatter to primary ratio (SPR) maps found in tomosynthesis of the breast. This characterization was performed using Monte Carlo simulations, based on the Geant4 toolkit, that simulate the conditions present in a digital tomosynthesis system, including the simulation of the compressed breast in both the cranio-caudal (CC) and the medio-lateral oblique (MLO) views. The variation of the scatter PSF with varying tomosynthesis projection angle, as well as the effects of varying breast glandular fraction and x-ray spectrum, was analyzed. The behavior of the SPR for different projection angle, breast size, thickness, glandular fraction, and x-ray spectrum was also analyzed, and computer fit equations for the magnitude of the SPR at the center of mass for both the CC and the MLO views were found. Within mammographic energies, the x-ray spectrum was found to have no appreciable

  13. Evaluation of average glandular dose in digital and conventional systems of the mammography; Avaliacao da dose glandular media em sistemas digitais e convencionais de mamografia

    Energy Technology Data Exchange (ETDEWEB)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J., E-mail: alinecx90@gmail.com, E-mail: vsmdbarros@gmail.com, E-mail: hjkhoury@gmail.com [Universidade Federal de Pernambuco (UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Mello, Francisca A. de, E-mail: francissamello@yahoo.com.br [Hospital das Clinicas do Recife (HCR/UFPE), PE (Brazil)

    2014-07-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  14. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Science.gov (United States)

    Chen, Fangfang; Hao, Fuhua; Li, Changfu; Gou, Junbo; Lu, Dayan; Gong, Fujun; Tang, Huiru; Zhang, Yansheng

    2013-01-01

    Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin) were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  15. Identifying three ecological chemotypes of Xanthium strumarium glandular trichomes using a combined NMR and LC-MS method.

    Directory of Open Access Journals (Sweden)

    Fangfang Chen

    Full Text Available Xanthanolides, as the sesquiterpene lactones, are reportedly the major components for the pharmacological properties of X. strumarium L. species. Phytochemical studies indicated that the glandular structures on the surface of plant tissues would form the primary sites for the accumulation of this class of the compounds. As the interface between plants and their natural enemies, glandular trichomes may vary with respect to which of their chemicals are sequestered against different herbivores in different ecologies. However, to date, no data are available on the chemical characterisation of X. strumarium glandular cells. In this study, the trichome secretions of the X. strumarium species originating from nineteen unique areas across eleven provinces in China, were analysed by HPLC, LC-ESI-MS and NMR. For the first time three distinct chemotypes of X. strumarium glandular trichomes were discovered along with the qualitative and quantitative evaluations of their presence of xanthanolides; these were designated glandular cell Types I, II, and III, respectively. The main xanthanolides in Type I cells were 8-epi-xanthatin and xanthumin while no xanthatin was detected. Xanthatin, 8-epi-xanthatin, and xanthumin dominated in Type II cells with comparable levels of each being present. For Type III cells, significantly higher concentrations of 8-epi-xanthatin or xanthinosin (relative to xanthatin were detected with xanthinosin only being observed in this type. Further research will focus on understanding the ecological and molecular mechanism causing these chemotype differences in X. strumarium glandular structures.

  16. Morphological differentiation of non-glandular and glandular trichomes on Marrubium vulgare L.

    Directory of Open Access Journals (Sweden)

    Marta Dmitruk

    2014-04-01

    Full Text Available Marrubium vulgare L., commonly known as a white horehound or common horehound, belongs to the plant family Lamiaceae. It is a perennial aromatic herb which grows naturally in Europe, Asia, and America. Since ancient Egypt, this species has been known as a remedy for upper respiratory tract ailments. Nowadays, horehound is used in herbal medicine for treatment of liver diseases, biliary tract disorders, and for increasing the appetite and supporting the function of the stomach. The main biologically active substances in M. vulgare organs are: marrubiin, tannins, essential oils, and ursolic acid. The paper presents micromorphological analyses of non-glandular and glandular trichomes of M. vulgare. The research material was sampled from the plant collection in the Botanical Garden of the Maria Curie-Sklodowska University in Lublin (51°14′ N, 22°34′ E. The above-ground parts of horehound were collected during the flowering period in July 2013. Using light microscopy (LM and scanning electron microscopy (SEM, the types and sizes of trichomes from the stem, leaf, calyx, and corolla were investigated. The results of the microscopic observations show that the surfaces of M. vulgare vegetative and reproductive organs are densely clothed with glandular and non-glandular trichomes. The glandular trichomes are of two main types: peltate and capitate. Peltate trichomes consist of a short stalk cell and a large head with secretory cells arranged in a circle. The height of a mature trichome is about 31.33 μm and the diameter of the head is 31.47 μm. The substance produced by secretory cells passes through the apical walls and accumulates within a space between the cuticle and the cell wall layer. Capitate long trichomes with a basal cell, long stalk, neck cell, and a unicellular head are 36.65 μm long and the diameter of the head is about 15.6 μm. There are two types of short capitate trichomes: with a bicellular head and a unicellular stalk and with

  17. Structure and histochemistry of the glandular trichomes on the ...

    African Journals Online (AJOL)

    The glandular trichomes were classified into two subpopulations, namely the peltate and capitate glandular trichomes. The former was characterized by a short stalk and a large four-celled secretory head, while the latter was further subdivided into two groups; one has a short unicellular stalk and two-cellular head (type I), ...

  18. Evaluation of mean glandular dose in a full-field digital mammography unit in Tabriz (IR)

    International Nuclear Information System (INIS)

    Riabi, H. A.; Mehnati, P.; Mesbahi, A.

    2010-01-01

    This study was aimed at evaluating the mean glandular dose (MGD) and affecting factors during mammography examinations by a full-field digital mammography unit. An extensive quality control program was performed to assure that the unit is properly working. Required information including compressed breast thickness (CBT), breast parenchymal pattern and technical factors used for imaging were recorded. An entrance skin exposure measurement was also performed using slabs of polymethylmethacrylate with 2-8 cm thickness. On the basis of recorded information and measured data, the MGD was estimated for 1145 mammography examinations obtained from 298 patients. Mean CBTs of 4.9 and 5.8 cm and MGDs of 2 and 2.4 mGy were observed for cranio-caudal and medio-lateral oblique views, respectively. Significant correlation was seen between MGD and CBT, breast parenchymal pattern and applied kVp and mAs. (authors)

  19. Elimination of salmonella from animal glandular products.

    Science.gov (United States)

    De Fiebre, C W; Burck, K T; Feldman, D

    1969-03-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin-a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination.

  20. Elimination of Salmonellae from Animal Glandular Products

    Science.gov (United States)

    De Fiebre, Conrad W.; Burck, Kenneth T.; Feldman, David

    1969-01-01

    Methods for the elimination of salmonellae from selected powdered pharmaceuticals of animal glandular origin were studied. Terminal heat treatment under carefully controlled conditions was effective for pancreatin—a powder containing proteolytic, amylolytic, and lipolytic enzymes prepared from hog pancreas glands. Use of this method resulted in a significant reduction in the number of salmonella-positive batches and also reduced the testing procedures required to confirm the absence of viable salmonellae among the majority of samples tested. Powders such as stomach substance and thyroid, in which the biological activity is not enzyme in nature, were treated successfully with acidified organic solvents. Other methods were investigated but were not suitable because of a deleterious effect on the biological activity or physical properties of the product or an inability to effect salmonella elimination. PMID:5780395

  1. Glandular odontogenic cyst: A case report

    International Nuclear Information System (INIS)

    Tambawaia, Shahnaz S.; Karjodkar, Freny R.; Yadav, Archana; Sansare, Kaustubh; Sontakke, Subodh

    2014-01-01

    Glandular odontogenic cysts (GOCs) are rare intrabony solitary or multiloculated cysts of odontogenic origin. The importance of GOCs lies in the fact that they exhibit a propensity for recurrence similar to keratocystic odontogenic tumors and that they may be confused microscopically with central mucoepidermoid carcinoma. Thus, the oral and maxillofacial radiologists play an important role in definitive diagnosis of GOC based on distinctive cases; though they are rare. In large part, this is due to the GOC's complex and frequently non-specific histopathology. This report describes a case of GOC occurrence in the posterior mandibular ramus region in a 17-year-old female, which is a rare combination of site, age, and gender for occurrence.

  2. Glandular odontogenic cyst: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Tambawaia, Shahnaz S.; Karjodkar, Freny R.; Yadav, Archana; Sansare, Kaustubh; Sontakke, Subodh [Nair Hospital Dental College, Mumbai (India)

    2014-03-15

    Glandular odontogenic cysts (GOCs) are rare intrabony solitary or multiloculated cysts of odontogenic origin. The importance of GOCs lies in the fact that they exhibit a propensity for recurrence similar to keratocystic odontogenic tumors and that they may be confused microscopically with central mucoepidermoid carcinoma. Thus, the oral and maxillofacial radiologists play an important role in definitive diagnosis of GOC based on distinctive cases; though they are rare. In large part, this is due to the GOC's complex and frequently non-specific histopathology. This report describes a case of GOC occurrence in the posterior mandibular ramus region in a 17-year-old female, which is a rare combination of site, age, and gender for occurrence.

  3. MORPHOLOGIC CONSIDERATIONS ABOUT THE WALL OF THE GLANDULAR STOMACH OF YOUNG RABBITS (Oryctolagus cuniculus)

    OpenAIRE

    de Oliveira, Larissa Renata; Molinari, Sonia Lucy; Natali, Maria Raquel Marçal; Michelan, Andrea Cristiane; Scapinello, Claúdio

    2001-01-01

    The morphology of the stomach may vary between species as a function of feeding habits, differences on the cellular composition of the mucosa of the stomach wall and the different functions it carries out. Morphofunctional variations of the stomach of several animals along phylogeny led us to investigate the morphology of the wall of the glandular stomach of rabbits. We used the stomachs of 32 young rabbits (Oryctolagus cuniculus) from the White New Zealand strain, coming from the Experimenta...

  4. Evaluation of average glandular dose in digital and conventional systems of the mammography

    International Nuclear Information System (INIS)

    Xavier, Aline C.S.; Barros, Vinicius S.M.; Khoury, Hellen J.

    2014-01-01

    Mammography is currently the most effective method of diagnosis and detection of breast pathologies. The main interest in this kid of exam comes from the high incidence rate of breast cancer and necessity of high quality images for accurate diagnosis. Digital mammography systems have several advantages compared to conventional systems, however the use of digital imaging systems is not always integrated to an image acquisition protocol. Therefore, it is questionable if digital systems truly reduce the dose received by the patient, because many times is introduced in the clinics without optimization of the image acquisition protocols. The aim of this study is to estimate the value of incident air Kerma and average glandular dose (AGD) in patients undergoing conventional and digital mammography systems in Recife. This study was conducted with 650 patients in three hospitals. The value of incident air Kerma was estimated from the measurement of the yield of equipment and irradiation parameters used for each patient. From these results and using the methodology proposed by Dance et al. the value of the average glandular dose was calculated. The results obtained show that the lowest value of AGD was found with conventional screen-film system, indicating that the parameters for image acquisition with digital systems are not optimized. It was also observed that the institutions with digital systems use lower breast compression values than the conventional. (author)

  5. Estimate of average glandular dose (AGD) in national clinics of mammography

    International Nuclear Information System (INIS)

    Mora, Patricia; Segura, Helena

    2004-01-01

    The breast cancer represents the second cause of death by cancer in the femme population of our country. The specialized equipment for the obtaining of the mammographic images is higher every day and its use increases daily. The quality of the radiographic study is linked to the dose that this tissue intrinsically sensible receives to the ionizing radiations. The present work makes the first national study to quantify the average glandular doses and to connect them with the diagnostic quality and the recommendations to international scale. (Author) [es

  6. Average glandular dose in routine mammography screening using a Sectra Microdose Mammography unit

    International Nuclear Information System (INIS)

    Hemdal, B.; Herrnsdorf, L.; Andersson, I.; Bengtsson, G.; Heddson, B.; Olsson, M.

    2005-01-01

    The Sectra MicroDose Mammography system is based on direct photon counting (with a solid-state detector), and a substantially lower dose to the breast than when using conventional system can be expected. In this work absorbed dose measurements have been performed for the first unit used in routine mammography screening (at the Hospitals of Helsingborg (Sweden)). Two European protocols on dosimetry in mammography have been followed. Measurement of half value layer (HVL) cannot be performed as prescribed, but this study has demonstrated than non-invasive measurements of HVL can be performed accurately with a sensitive and well collimated solid-state detector with simultaneous correction for the energy dependence. The average glandular dose for a 50 mm standard breast with 50% glandularity, simulated by 45 mm polymethylmethacrylate, was found to be 0.21 and 0.28 mGy in March and December 2004, respectively. These values are much lower than for any other mammography system on the market today. It has to be stressed that the measurement were made using the current clinical settings and that no systematic optimisation of the relationship between absorbed dose and diagnostic image quality has been performed within the present study. In order to further increase the accuracy of absorbed dose measurements for this unit, the existing dose protocols should be revised to account also for the tungsten/aluminium anode/filter combination, the multi-slit pre-collimator device and the occurrence of a dose profile in the scanning direction. (authors)

  7. Gynecomastia: glandular-liposculpture through a single transaxillary one hole incision.

    Science.gov (United States)

    Lee, Yung Ki; Lee, Jun Hee; Kang, Sang Yoon

    2018-04-01

    Gynecomastia is characterized by the benign proliferation of breast tissue in men. Herein, we present a new method for the treatment of gynecomastia, using ultrasound-assisted liposuction with both conventional and reverse-cutting edge tip cannulas in combination with a pull-through lipectomy technique with pituitary forceps through a single transaxillary incision. Thirty patients were treated with this technique at the author's institution from January 2010 to January 2015. Ten patients were treated with conventional surgical excision of the glandular/fibrous breast tissue combined with liposuction through a periareolar incision before January 2010. Medical records, clinical photographs and linear analog scale scores were analyzed to compare the surgical results and complications. The patients were required to rate their cosmetic outcomes based on the linear analog scale with which they rated their own surgical results; the mean overall average score indicated a good or high level of satisfaction. There were no incidences of skin necrosis, hematoma, infection and scar contracture; however, one case each of seroma and nipple inversion did occur. Operative time was reduced overall using the new technique since it is relatively simple and straightforward. According to the evaluation by the four independent researchers, the patients treated with this new technique showed statistically significant improvements in scar and nipple-areolar complex (NAC) deformity compared to those who were treated using the conventional method. Glandular liposculpture through a single transaxillary incision is an efficient and safe technique that can provide aesthetically satisfying and consistent results.

  8. A study on the image quality of mammography and the average glandular dose

    International Nuclear Information System (INIS)

    Lee, In Ja; Kim, Hak Sung; Kim, Sung Soo; Huh, Joon

    2002-01-01

    We came to the following conclusion as the results of experiment on the image quality of mammography and the average glandular dose using 4 apparatuses at 3 hospital in Seoul. Whereas the measurement of half value layer showed no differences among the apparatuses, the measurement by an attenuation curve method showed some differences by 5.9%. There were 9.1% differences in the measurement by aluminum conversion method. The basic density of an automatic exposure control unit must be D = 1.40, but there was no automatic exposure unit adjusted precisely at any hospital. The unit at the B hospital exceeded the allowable limit by ± 0.15. In the photographing using an automatic exposure control unit and the management of an automatic film processor using a sensitometer, most automatic film processors were well kept. But in some cases the mean value of a fluctuation coefficient exceeded the allowable limit. There is a need for more cautious management. The image quality of breast phantom photography was affected by the screen/film system among the hospital. The average glandular dose at a breast of 4.2 cm thickness depended on the tube voltage, In the case of Mo/Mo, it was measured 0.26 ∼ 1.39 mGy less than ACR standard 3.0 mGy

  9. Optimization of technique factors for a silicon diode array full-field digital mammography system and comparison to screen-film mammography with matched average glandular dose

    International Nuclear Information System (INIS)

    Berns, Eric A.; Hendrick, R. Edward; Cutter, Gary R.

    2003-01-01

    Contrast-detail experiments were performed to optimize technique factors for the detection of low-contrast lesions using a silicon diode array full-field digital mammography (FFDM) system under the conditions of a matched average glandular dose (AGD) for different techniques. Optimization was performed for compressed breast thickness from 2 to 8 cm. FFDM results were compared to screen-film mammography (SFM) at each breast thickness. Four contrast-detail (CD) images were acquired on a SFM unit with optimal techniques at 2, 4, 6, and 8 cm breast thicknesses. The AGD for each breast thickness was calculated based on half-value layer (HVL) and entrance exposure measurements on the SFM unit. A computer algorithm was developed and used to determine FFDM beam current (mAs) that matched AGD between FFDM and SFM at each thickness, while varying target, filter, and peak kilovoltage (kVp) across the full range available for the FFDM unit. CD images were then acquired on FFDM for kVp values from 23-35 for a molybdenum-molybdenum (Mo-Mo), 23-40 for a molybdenum-rhodium (Mo-Rh), and 25-49 for a rhodium-rhodium (Rh-Rh) target-filter under the constraint of matching the AGD from screen-film for each breast thickness (2, 4, 6, and 8 cm). CD images were scored independently for SFM and each FFDM technique by six readers. CD scores were analyzed to assess trends as a function of target-filter and kVp and were compared to SFM at each breast thickness. For 2 cm thick breasts, optimal FFDM CD scores occurred at the lowest possible kVp setting for each target-filter, with significant decreases in FFDM CD scores as kVp was increased under the constraint of matched AGD. For 2 cm breasts, optimal FFDM CD scores were not significantly different from SFM CD scores. For 4-8 cm breasts, optimum FFDM CD scores were superior to SFM CD scores. For 4 cm breasts, FFDM CD scores decreased as kVp increased for each target-filter combination. For 6 cm breasts, CD scores decreased slightly as k

  10. The relationship between statins and breast cancer prognosis varies by statin type and exposure time: a meta-analysis.

    Science.gov (United States)

    Liu, Binliang; Yi, Zongbi; Guan, Xiuwen; Zeng, Yi-Xin; Ma, Fei

    2017-07-01

    Breast cancer is the most common cancer in females and the leading cause of death worldwide. The effects of statins on breast cancer prognosis have long been controversial; thus, it is important to investigate the relationship between statin type, exposure time, and breast cancer prognosis. This study sought to explore the effect of statins, as well as the different effects of statin solubility and variable follow-up times, on breast cancer prognosis. We searched the MEDLINE (via PubMed), EMBASE (via OvidSP), Cochrane Library, and ISI Web of Knowledge databases using combinations of the terms "breast neoplasms[MeSH]," "statins" or "lipid-lowering drug," "prognosis" or "survival," or "mortality" or "outcome" with no limit on the publication date. We searched the databases between inception and October 15, 2016. Reference lists of the included studies and relevant reviews were also manually screened. The initial search identified 71 publications, and 7 of these studies, which included a total of 197,048 women, met the selection criteria. Two authors independently screened each study for inclusion and extracted the data. The data were analyzed using Stata/SE 11.0. Overall statin use was associated with lower cancer-specific mortality and all-cause mortality, although the benefit appeared to be constrained by statin type and follow-up time. Lipophilic statins were associated with decreased breast cancer-specific and all-cause mortality; however, hydrophilic statins were weakly protective against only all-cause mortality and not breast cancer-specific mortality. Of note, one group with more than 4 years of follow-up did not show a significant correlation between statin use and cancer-specific mortality or all-cause mortality, whereas groups with less than 4 years of follow-up still showed the protective effect of statins against cancer-specific mortality and all-cause mortality. Although statins can reduce breast cancer patient mortality, the benefit appears to be

  11. Determination of mean glandular dose on patients and phantom in X-ray mammography

    International Nuclear Information System (INIS)

    Avramova-Cholakova, S.; Vassileva, J.

    2008-01-01

    The statistics of breast cancer rate in Bulgaria show a tendency towards increase of the morbidity from this disease. Last years campaigns against breast cancer are organized yearly. This leads to an increased number of screening and diagnostic mammograms that are made in the country. The dose associated with the examination is very low but not slightingly small. The glandular tissue in the breast is considered to be the most sensitive in relation to the radiation exposure. Several publications propose different methods, measurement set up or conversion coefficients for the calculation of the mean glandular dose (MGD) delivered to the breast during the X-ray examination. The question about the standardization of the measurement procedures arises since the differences in the results obtained using different methodologies may be quite big. The aim of this work is to develop a standard procedure for the measurement of MGD based on the recommendations mentioned in the European protocol on dosimetry in mammography, the European protocol for the quality control of the physical and technical aspects of mammography screening and the Code of practice: TRS 457 of the IAEA. Five contemporary film-screen mammography units were included in this study. Attention should be paid to the measurement set up. The reference point is chosen 6 cm from the chest wall edge laterally centered. If an ionization chamber is used for dose measurements the compression plate should be placed in close contact with it. If solid state detectors are used the compression plate should be put away from the detector and the output recalculated like if the plate is near the detector. The conversion coefficients for age dependence are not used in this study as not appropriate for the population included in it. PMMA measurements for the determination of diagnostic reference levels could be used but more correct results would be obtained with patient measurements

  12. Structure and distribution of glandular and non-glandular trichomes on above-ground organs in Inula helenium L. (Asteraceae

    Directory of Open Access Journals (Sweden)

    Aneta Sulborska

    2014-01-01

    Full Text Available Micromorphology and distribution of glandular and non-glandular trichomes on the above-ground organs of Inula helenium L. were investigated using light and scanning electron microscopy (SEM. Two types of biseriate glandular trichomes, i.e. sessile and stalk hairs, and non-glandular trichomes were recorded. Sessile glandular trichomes were found on all examined I. helenium organs (with their highest density on the abaxial surface of leaves and disk florets, and on stems, whereas stalk glandular trichomes were found on leaves and stems. Sessile trichomes were characterised by a slightly lower height (58–103 μm and width (32–35 μm than the stalk trichomes (62–111 μm x 31–36 μm. Glandular hairs were composed of 5–7 (sessile trichomes or 6–9 (stalk trichomes cell tiers. Apical trichome cell tiers exhibited features of secretory cells. Secretion was accumulated in subcuticular space, which expanded and ruptured at the top, and released its content. Histochemical assays showed the presence of lipids and polyphenols, whereas no starch was detected. Non-glandular trichomes were seen on involucral bracts, leaves and stems (more frequently on involucral bracts. Their structure comprised 2–9 cells; basal cells (1–6 were smaller and linearly arranged, while apical cells had a prozenchymatous shape. The apical cell was the longest and sharply pointed. Applied histochemical tests revealed orange-red (presence of lipids and brow colour (presence of polyphenols in the apical cells of the trichomes. This may suggest that beside their protective role, the trichomes may participate in secretion of secondary metabolites.

  13. A new look at breast density and breast cancer risk

    NARCIS (Netherlands)

    Haars, G.

    2008-01-01

    Breast density, as visible on mammograms, comprises connective and epithelial tissue and can be seen to represent the glandular target tissue for breast cancer, whereas the non-dense tissue mainly comprises fat. High percentages of density are established to be one of the strongest risk factors of

  14. [Treatment of gynecomastia by a combined method of liposuction and semicircular periareolar incision glandular organ partial resection].

    Science.gov (United States)

    Liu, Su; Kuang, Ruixia; Chen, Zhenyu; Li, Huichao; Zhang, Weina; Wang, Zhiguo; Miao, Yuanxin; Chen, Lu

    2008-12-01

    To evaluate the effect of the combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia. From June 2004 to June 2006, 40 patients, aged 11-41 years old, were treated, with no-nodule (n = 10), nodule (n = 22) and female-breast-like with nodules (n = 8). Three patients were unilateral and 37 ones were bilateral. The levels of serum prolactin, luteinizing hormone, follicle stimulating hormone, estradiol, testosterone and cortisol were normal in 38 patients, while in the other 2 patients, the levels of serum prolactin, luteinizing hormone, follicle stimulating hormone and estradiol were higher than normal, and the testosterone level was lower. Liposuction alone was performed in 10 no-nodule patients (lipo-type), and combined liposuction and semicircular periareolar incision glandular organ partial resection were conducted in the other 30 patients (lipo-glandular type). RESULTS; Except for 2 cases in which hematoma and a small amount of effusion were found on the first and second day postoperatively and then obtained healing by first intention right after hematoma removal in time, all the other patients incisions obtained healing by first intention. Nipple numbness occurred in 3 cases on the first day postoperatively and no special treatment was conducted. There was still nipple hypesthesia in these 3 cases after 6-month follow-up. There were no complications such as hematoma, effusion, nipple and mammary areola necrosis, and nipple hypesthesia in other patients. All the 40 patients were followed up for 6-24 months (13 months on average). They were satisfied with their chest figures and no recurrence was observed. The combined method of liposuction and semicircular periareolar incision glandular organ partial resection in the treatment of gynecomastia has many advantages, such as safe, micro-scars, natural and beautiflhl male breast figures as well as high patients' satisfaction.

  15. Comparative evaluation of average glandular dose and image of digital mammography and film mammography in Minas Gerais, Brazil

    International Nuclear Information System (INIS)

    Nogueira, M.; Leyton, F.; Rodrigue, L. L.C.; Oliveira, M.A.; Joana, G.S.; Silva, S.D.

    2015-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. Mammography is the best method for breast-cancer screening and is capable of reducing mortality rates To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. Digital mammography has been proposed as a substitute for film mammography given the benefits inherent to digital technology. The purpose of our study was to compare the technical performance of digital mammographic and screen-film mammography. A PMMA phantom with objects to simulate breast structures. For the screen/film (SF) technique the results showed that 54% mammography units did not achieve the minimum acceptable performance as far the image quality. Besides, 67% services showed inadequate performance in their processing systems, which had significant influence on the image quality. At the mean glandular dose only 44% of digital systems evaluated were compliant in all thicknesses of PMMA. The average glandular dose AGD was 90 % higher than in screen/film systems. (authors)

  16. Morphology and histochemistry of glandular trichomes of Orobanche alba Stephan ex Willd

    Directory of Open Access Journals (Sweden)

    Aneta Sulborska

    2014-04-01

    Full Text Available Orobanche alba Stephan ex Willd is an achlorophyllous root parasite rare in Poland. It prefers dry and sunny slopes, xerothermic grasslands and pastures, mountain pastures, light scrubs, and rock fissures and ledges. The hosts of O. alba include Thymus polytrichus A. ern. ex Borbás, Clinopodium vulgare L. and Origanum vulgare L. The tick and fleshy 10-70 cm high stem in this species bears an inflorescence composed of zygomorphic, white or yellow “spotted” flowers covered by purple glandular trichomes. Glandular trichomes of this type are also borne on other parts of the plant, i.e. on the stem, scaly leaves, sepals, filaments, and the style. The secondary metabolites secreted by the glandular trichomes are related to defense of plants against the attack of herbivores and pathogens or act as attractants to pollinators or for fruit dispersal. The micromorphology and histochemistry of the glandular trichomes in O. alba were examined using scanning electron and light microscopes. In order to determine the type of secondary metabolites produced by the trichomes, the flowing histochemical assays were used: Sudan III and neutral red for detection of lipophilic compounds, IKI for detection of starch, and FeCl3 for detection of phenolic compounds. The peltate glandular trichomes of O. alba were characterised by a varied length (0.15‑0.48 mm and different activity phases. The trichome was composed of one larger basal epidermal cell, 1-3 hyaline stalk cells with a striated cuticle, a neck cell with a smooth cuticle on the surface, and a globose head formed of 8-18 secretory cells arranged in a circle. Many stalk cells of the trichomes, particularly those located on the corolla, contained anthocyanins, which give the trichomes dark carmine colour. In turn, the colour of the heads was dependent on trichome age: the heads were brown in older trichomes and yellow in younger hairs. Secretion was produced by both young and older trichomes. It penetrated

  17. Development of a physical 3D anthropomorphic breast phantom

    Energy Technology Data Exchange (ETDEWEB)

    Carton, Ann-Katherine; Bakic, Predrag; Ullberg, Christer; Derand, Helen; Maidment, Andrew D. A. [Department of Radiology, University of Pennsylvania, 1 Silverstein Building, 3400 Spruce Street, Philadelphia, Pennsylvania 19104-4206 (United States); XCounter AB, Svaerdvaegen 11, SE-182 33 Danderyd (Sweden); Department of Radiology, University of Pennsylvania, 1 Silverstein Building, 3400 Spruce Street, Philadelphia, Pennsylvania 19104-4206 (United States)

    2011-02-15

    Purpose: Develop a technique to fabricate a 3D anthropomorphic breast phantom with known ground truth for image quality assessment of 2D and 3D breast x-ray imaging systems. Methods: The phantom design is based on an existing computer model that can generate breast voxel phantoms of varying composition, size, and shape. The physical phantom is produced in two steps. First, the portion of the voxel phantom consisting of the glandular tissue, skin, and Cooper's ligaments is separated into sections. These sections are then fabricated by high-resolution rapid prototyping using a single material with 50% glandular equivalence. The remaining adipose compartments are then filled using an epoxy-based resin (EBR) with 100% adipose equivalence. The phantom sections are stacked to form the physical anthropomorphic phantom. Results: The authors fabricated a prototype phantom corresponding to a 450 ml breast with 45% dense tissue, deformed to a 5 cm compressed thickness. Both the rapid prototype (RP) and EBR phantom materials are radiographically uniform. The coefficient of variation (CoV) of the relative attenuation between RP and EBR phantom samples was <1% and the CoV of the signal intensity within RP and EBR phantom samples was <1.5% on average. Digital mammography and reconstructed digital breast tomosynthesis images of the authors' phantom were reviewed by two radiologists; they reported that the images are similar in appearance to clinical images, noting there are still artifacts from air bubbles in the EBR. Conclusions: The authors have developed a technique to produce 3D anthropomorphic breast phantoms with known ground truth, yielding highly realistic x-ray images. Such phantoms may serve both qualitative and quantitative performance assessments for 2D and 3D breast x-ray imaging systems.

  18. Glandular trichome density and essential oil composition in leaves and inflorescences of Lippia origanoides Kunth (Verbenaceae in the Brazilian Cerrado

    Directory of Open Access Journals (Sweden)

    Luiz R.S. Tozin

    2015-06-01

    Full Text Available The essential oils from leaves and inflorescences of Lippia origanoides Kunth present aromatic and medicinal potential and have been used to treat several diseases, including melanoma. In Brazil, L. origanoides is commonly found in campo cerrado and cerrado stricto sensu, physiognomies featured mainly by the differential light conditions to which short and medium-sized plants are subjected. Our aim was to investigate the glandular trichome density and the yield and chemical composition of the essential oils in leaves and inflorescences of L. origanoides from campo cerrado and cerrado stricto sensu. For glandular density analysis, leaves and inflorescences were processed according to conventional techniques for scanning electron microscopy. The essential oils of leaves and inflorescences were obtained by hydrodistillation and identified with gas chromatography. Bracts and sepals showed the highest glandular density, followed by petals and leaves. The glandular density in the abaxial leaf surface was higher in individuals from the campo cerrado. In both populations the essential oil yield was higher in inflorescences than in leaves. The chemical composition of the essential oils varied among individuals from different areas and inside a same population. Our results demonstrated the chemical plasticity of L. origanoides suggesting the importance of monitoring its popular use.

  19. Glandular trichome density and essential oil composition in leaves and inflorescences of Lippia origanoides Kunth (Verbenaceae) in the Brazilian Cerrado.

    Science.gov (United States)

    Tozin, Luiz R S; Marques, Marcia O M; Rodrigues, Tatiane M

    2015-01-01

    The essential oils from leaves and inflorescences of Lippia origanoides Kunth present aromatic and medicinal potential and have been used to treat several diseases, including melanoma. In Brazil, L. origanoides is commonly found in campo cerrado and cerrado stricto sensu, physiognomies featured mainly by the differential light conditions to which short and medium-sized plants are subjected. Our aim was to investigate the glandular trichome density and the yield and chemical composition of the essential oils in leaves and inflorescences of L. origanoides from campo cerrado and cerrado stricto sensu. For glandular density analysis, leaves and inflorescences were processed according to conventional techniques for scanning electron microscopy. The essential oils of leaves and inflorescences were obtained by hydrodistillation and identified with gas chromatography. Bracts and sepals showed the highest glandular density, followed by petals and leaves. The glandular density in the abaxial leaf surface was higher in individuals from the campo cerrado. In both populations the essential oil yield was higher in inflorescences than in leaves. The chemical composition of the essential oils varied among individuals from different areas and inside a same population. Our results demonstrated the chemical plasticity of L. origanoides suggesting the importance of monitoring its popular use.

  20. Effect of implant vs. tissue reconstruction on cancer specific survival varies by axillary lymph node status in breast cancer patients.

    Directory of Open Access Journals (Sweden)

    Qian Ouyang

    Full Text Available To compare the breast cancer-specific survival (BCSS between patients who underwent tissue or implant reconstruction after mastectomy.We used the database from Surveillance, Epidemiology, and End Results (SEER registries and compared the BCSS between patients who underwent tissue and implant reconstruction after mastectomy. Cox-regression models were fitted, adjusting for known clinicopathological features. The interaction between the reconstruction types (tissue/implant and nodal status (N-stage was investigated.A total of 6,426 patients with a median age of 50 years were included. With a median follow up of 100 months, the 10-year cumulative BCSS and non-BCSS were 85.1% and 95.4%, respectively. Patients who underwent tissue reconstruction had tumors with a higher T-stage, N-stage, and tumor grade and tended to be ER/PR-negative compared to those who received implant reconstruction. In univariate analysis, implant-reconstruction was associated with a 2.4% increase (P = 0.003 in the BCSS compared with tissue-reconstruction. After adjusting for significant risk factors of the BCSS (suggested by univariate analysis and stratifying based on the N-stage, there was only an association between the reconstruction type and the BCSS for the N2-3 patients (10-year BCSS of implant vs. tissue-reconstruction: 68.7% and 59.0%, P = 0.004. The 10-year BCSS rates of implant vs. tissue-reconstruction were 91.7% and 91.8% in N0 patients (P>0.05 and 84.5% and 84.4% in N1 patients (P>0.05, respectively.The implant (vs. tissue reconstruction after mastectomy was associated with an improved BCSS in N2-3 breast cancer patients but not in N0-1 patients. A well-designed, prospective study is needed to further confirm these findings.

  1. Glandular Trichomes and Essential Oil of Thymus quinquecostatus

    Directory of Open Access Journals (Sweden)

    Ping Jia

    2013-01-01

    Full Text Available The distribution and types of glandular trichomes and essential oil chemistry of Thymus quinquecostatus were studied. The glandular trichomes are distributed on the surface of stem, leaf, rachis, calyx and corolla, except petiole, pistil and stamen. Three morphologically distinct types of glandular trichomes are described. Peltate trichomes, consisting of a basal cell, a stalk cell and a 12-celled head, are distributed on the stem, leaf, corolla and outer side of calyx. Capitate trichomes, consisting of a unicellular base, a 1–2-celled stalk and a unicellular head, are distributed more diffusely than peltate ones, existing on stem, leaf, rachis and calyx. Digitiform trichomes are just distributed on the outer side of corolla, consisting of 1 basal cell, 3 stalk cells and 1 head cell. All three types of glandular trichomes can secrete essential oil, and in small capitate trichomes of rachis, all peltate trichomes and digitiform trichomes, essential oil is stored in a large subcuticular space, released by cuticle rupture, whereas, in other capitate trichomes, essential oil crosses the thin cuticle. The essential oil of T. quinquecostatus is yellow, and its content is highest in the growth period. 68 constituents were identified in the essential oils. The main constituent is linalool.

  2. Breast compression and radiation dose in two different mammographic oblique projections: 45 and 60 deg

    International Nuclear Information System (INIS)

    Brnic, Zoran; Hebrang, Andrija

    2001-01-01

    Introduction: Standard mammography includes two views, craniocaudal and medio-lateral oblique. Depending on patient's body constitution, central beam angle in mediolateral oblique projection may vary, with 45 deg. being suitable for the majority of patients in routine daily practice. With continuous improvement in X-ray technology and radiographers' training, the risk of radiation induced cancerogenesis is considerably reduced and acceptable when compared to benefit. However, the risk still exists, being cumulative and directly related to absorbed glandular dose. There is no minimal dose of radiation which is absolutely harmless, and every effort to reduce the dose is welcome. In this retrospective study two different angles (45 vs. 60 deg.) of mediolateral oblique view were compared according to radiation dose and efficacy of breast compression. Patients and methods: In 52 women, additional 60 deg. oblique films were done after craniocaudal and mediolateral oblique 45 deg.-films, with the same kVp and positioning technique. Breast thickness, time-current products (mA s) and absorbed doses were compared between 45 deg. - and 60 deg.-films. Subgroups of women with large, small, prominent and pendulous breasts were analyzed separately, following the same methodology as for the whole group. Results: mA s were 11.5% lower and compression 7% better with an angle of 60 deg. than with 45 deg. In the subgroup of women with small breasts, mA s values were 13% lower and compression 9% better with 60 deg. than with 45 deg., while in the subgroup with large breasts, mA s were 9% lower and compression 5% better. In the subgroup of patients with pendulous breasts, mA s values were 12% lower and compression 10% better with 60 deg. than with 45 deg., while in the subgroup with prominent breasts, mA s values were 4% lower and compression 3% better. Absorbed glandular dose was estimated to be approximately 20% lower when an oblique mammogram was done with 60 deg. instead of 45 deg

  3. Genetic architecture of capitate glandular trichome density in florets of domesticated sunflower (Helianthus annuus L.)

    Science.gov (United States)

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. Capitate glandular trichomes can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resist...

  4. Individualised calculation of tissue imparted energy in breast tomosynthesis

    International Nuclear Information System (INIS)

    Geeraert, N.; Klausz, R.; Muller, S.; Bosmans, H.; Bloch, I.

    2016-01-01

    The imparted energy to the glandular tissue in the breast (glandular imparted energy, GIE) is proposed for an improved assessment of the individual radiation-induced risk resulting from X-ray breast imaging. GIE is computed from an estimation of the quantity and localisation of glandular tissue in the breast. After a digital breast tomosynthesis (DBT) acquisition, the volumetric glandular content (volumetric breast density, VBD) is computed from the central X-ray projection. The glandular tissue distribution is determined by labelling the DBT voxels to ensure the conservation of the VBD. Finally, the GIE is calculated by Monte Carlo computation on the resulting tissue-labelled DBT volume. For verification, the method was applied to 10 breast-shaped digital phantoms made of different glandular spheres in an adipose background, and to a digital anthropomorphic phantom. Results were compared to direct GIE computations on the phantoms considered as 'ground-truth'. The major limitations in accuracy are those of DBT, in particular the limited z-resolution. However, for most phantoms, the results can be considered as acceptable. (authors)

  5. Local breast density assessment using reacquired mammographic images.

    Science.gov (United States)

    García, Eloy; Diaz, Oliver; Martí, Robert; Diez, Yago; Gubern-Mérida, Albert; Sentís, Melcior; Martí, Joan; Oliver, Arnau

    2017-08-01

    The aim of this paper is to evaluate the spatial glandular volumetric tissue distribution as well as the density measures provided by Volpara™ using a dataset composed of repeated pairs of mammograms, where each pair was acquired in a short time frame and in a slightly changed position of the breast. We conducted a retrospective analysis of 99 pairs of repeatedly acquired full-field digital mammograms from 99 different patients. The commercial software Volpara™ Density Maps (Volpara Solutions, Wellington, New Zealand) is used to estimate both the global and the local glandular tissue distribution in each image. The global measures provided by Volpara™, such as breast volume, volume of glandular tissue, and volumetric breast density are compared between the two acquisitions. The evaluation of the local glandular information is performed using histogram similarity metrics, such as intersection and correlation, and local measures, such as statistics from the difference image and local gradient correlation measures. Global measures showed a high correlation (breast volume R=0.99, volume of glandular tissue R=0.94, and volumetric breast density R=0.96) regardless the anode/filter material. Similarly, histogram intersection and correlation metric showed that, for each pair, the images share a high degree of information. Regarding the local distribution of glandular tissue, small changes in the angle of view do not yield significant differences in the glandular pattern, whilst changes in the breast thickness between both acquisition affect the spatial parenchymal distribution. This study indicates that Volpara™ Density Maps is reliable in estimating the local glandular tissue distribution and can be used for its assessment and follow-up. Volpara™ Density Maps is robust to small variations of the acquisition angle and to the beam energy, although divergences arise due to different breast compression conditions. Copyright © 2017 Elsevier B.V. All rights reserved.

  6. Micromorphology of glandular structures in Echium vulgare L. flowers

    Directory of Open Access Journals (Sweden)

    Elżbieta Weryszko-Chmielewska

    2012-12-01

    Full Text Available The micromorphology of selected elements of Echium vulgare L. flowers was investigated, with special attention to the structure of the nectaries and the stigma of the pistil as well as types of trichomes occurring on the surface of the calyx. The nectary had the shape of an uneven disc located around the lower region of the four-parted ovary of the pistil. The glandular cells formed a tier with a height of 330 μm and a radial width of 144 μm. Nectar was secreted onto the nectary surface through anomocytic stomata located at the level of other epidermal cells. Most of the stomata were open, with a different dimension of the pore. Their largest number was observed at the base of the nectary, and 462 stomata were noted on the whole surface of the nectary. The cuticle on the surface of the guard cells formed fine, circular striae. The subsidiary cells formed striated cuticular ornamentation, with the striae arranged radially in the direction of the stoma, whereas on the surface of other epidermal cells the striae formed an arrangement with different directions. The epidermis on the surface of the stigma formed regularly arranged papillae with a fan-shaped, expanded upper part which had corrugated outer walls, whereas the base of the cell formed a widened small column. The epidermis of the abaxial part of the calyx was covered by numerous non-glandular trichomes of different length which were made up of one or several cells. The glandular trichomes in the epidermis of the calyx grew with smaller density compared to the protective trichomes, and they were composed of a 1-2-celled stalk and a glandular head.

  7. Antiviral agents for infectious mononucleosis (glandular fever).

    Science.gov (United States)

    De Paor, Muireann; O'Brien, Kirsty; Fahey, Tom; Smith, Susan M

    2016-12-08

    customised data extraction sheet. We used the GRADE criteria to rate the quality of the evidence. We pooled heterogeneous data where possible, and presented the results narratively where we could not statistically combine data. We included seven RCTs with a total of 333 participants in our review. Three trials studied hospitalised patients, two trials were conducted in an outpatient setting, while the trial setting was unclear in two studies. Participants' ages ranged from two years to young adults. The type of antiviral, administration route, and treatment duration varied between the trials. The antivirals in the included studies were acyclovir, valomaciclovir and valacyclovir. Follow-up varied from 20 days to six months. The diagnosis of IM was based on clinical symptoms and laboratory parameters.The risk of bias for all included studies was either unclear or high risk of bias. The quality of evidence was graded as very low for all outcomes and so the results should be interpreted with caution. There were statistically significant improvements in the treatment group for two of the 12 outcomes. These improvements may be of limited clinical significance.There was a mean reduction in 'time to clinical recovery as assessed by physician' of five days in the treatment group but with wide confidence intervals (CIs) (95% CI -8.04 to -1.08; two studies, 87 participants). Prospective studies indicate that clinical signs and symptoms may take one month or more to resolve and that fatigue may be persistent in approximately 10% of patients at six-month follow-up, so this may not be a clinically meaningful result.Trial results for the outcome 'adverse events and side effects of medication' were reported narratively in only five studies. In some reports authors were unsure whether an adverse event was related to medication or complication of disease. These results could not be pooled due to the potential for double counting results but overall, the majority of trials reporting this

  8. Assessment of mean glandular dose for patients in mammography in some Hospitals in Khartoum state

    International Nuclear Information System (INIS)

    Abu Elmola, Alaa Mahdi

    2016-12-01

    A mammography examination facilitates the early detection of breast cancer. However, the potential risk of radiation- induced carcinogenesis is also increased with such a procedure. Thus assessment of the breast dose is important. The objective of this study was to determine the mean glandular dose (MGD) resulting from cranio caudal(CC) and mediolateral oblique (MLO) views in one breast and the total dose per woman in Sudan, and to identify the factors affecting it. Measurements were performed to estimate mean glandular doses for 60 patients who underwent mammography examination in two clinics in Khartoum, Sudan.Doses were studied in RCH and NDC, centers which were using computed radiography(CR)devices. The piranha system was used for determining the MGD in this work. The characteristics of the radiographic equipment and the exposure data of each patient were recorded using designed format. The MGD was calculated from the measured incident Air kerma using appropriate conversion coefficients. The range of CBT was (1-7)cm for two projections. The respective averages for the CC and MLO projections were (4.55±1.38)mGy and (4.15±1.33) mGy, respectively. The average MGD per image was (4.3±1.35)mGy. The MGD per women was (8.6±1.35)mGy. The mean±SD MGD per image in the present study was lower than most of similar reports. The average MGD values recorded in this study were above the limiting value of the Institute of Physical Sciences in Medicine(2.0 mGy) and American College of Radiology (3.0 mGy recommendation. This suggests that mammography x-ray generators in this case are not capable of achieving acceptable dose levels for patients safety. Therefore, with consideration of all other factors, quality control program tests must be carried out periodically and frequently of the mammography equipment.(Author)

  9. Glandular dose and image quality control in mammography facilities with computerized radiography systems

    International Nuclear Information System (INIS)

    Dantas, Marcelino Vicente de Almeida

    2010-01-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  10. Guideline for determining the mean glandular dose according to DIN 6868-162 and threshold contrast visibility according to the quality assurance guideline for digital mammography systems.

    Science.gov (United States)

    Sommer, A; Schopphoven, S; Land, I; Blaser, D; Sobczak, T

    2014-05-01

    As part of the physico-technical quality assurance of the German breast cancer screening program, the threshold contrast visibility and the average glandular dose of every digital mammography system have to fulfill the requirements of the "European guidelines for quality assurance in breast cancer screening and diagnosis" (4th Edition). To accomplish uniform measurements in all federal states of Germany, the physical board of the reference centers developed a special guideline in 2009. Due to recent changes in the guidelines and standards, a second version of the guideline was developed by the reference centers. This guideline describes the determination of the average glandular dose as well as the CDMAM image acquisition and the CDMAM image evaluation. The determination of the threshold contrast visibility can be performed visually or automatically. The determination of the average glandular dose is based on DIN 6868 - 162 and the threshold contrast visibility test is based on the German "Quality Assurance Guideline". © Georg Thieme Verlag KG Stuttgart · New York.

  11. Breast

    International Nuclear Information System (INIS)

    Ribeiro, G.G.

    1985-01-01

    The treatment of malignant disease of the breast arouses more controversy and emotion than that of any other form of malignant disease. Many clinical trials have been carried out and others are still in progress. In addition, research work continues in regard to other aspects of the disease, such as epidemiology, population screening, and endocrine factors; yet little is really known about the true biological nature of carcinoma of the breast. A vast amount of literature has accumulated on the treatment of ''operable'' carcinoma of the breast, but it is not proposed to discuss here the merits or demerits of the various suggested treatments. Instead this chapter will be confined to the practical management of carcinoma of the breast as seen from the point of view of radiotherapist. For this reason greater attention will be paid to the radiotherapy techniques as practised at the Christie Hospital

  12. Human papillomavirus prevalence and type-distribution in cervical glandular neoplasias

    DEFF Research Database (Denmark)

    Holl, Katsiaryna; Nowakowski, Andrzej M; Powell, Ned

    2015-01-01

    Cervical glandular neoplasias (CGN) present a challenge for cervical cancer prevention due to their complex histopathology and difficulties in detecting preinvasive stages with current screening practices. Reports of human papillomavirus (HPV) prevalence and type-distribution in CGN vary, providing...... uncertain evidence to support prophylactic vaccination and HPV screening. This study [108288/108290] assessed HPV prevalence and type-distribution in women diagnosed with cervical adenocarcinoma in situ (AIS, N = 49), adenosquamous carcinoma (ASC, N = 104), and various adenocarcinoma subtypes (ADC, N = 461...... of CGN are HPV16/18/45-positive, the incorporation of prophylactic vaccination and HPV testing in cervical cancer screening are important prevention strategies. Our results suggest that special attention should be given to certain rarer ADC subtypes as most appear to be unrelated to HPV....

  13. Image quality, threshold contrast and mean glandular dose in CR mammography

    International Nuclear Information System (INIS)

    Jakubiak, R R; Gamba, H R; Neves, E B; Peixoto, J E

    2013-01-01

    In many countries, computed radiography (CR) systems represent the majority of equipment used in digital mammography. This study presents a method for optimizing image quality and dose in CR mammography of patients with breast thicknesses between 45 and 75 mm. Initially, clinical images of 67 patients (group 1) were analyzed by three experienced radiologists, reporting about anatomical structures, noise and contrast in low and high pixel value areas, and image sharpness and contrast. Exposure parameters (kV, mAs and target/filter combination) used in the examinations of these patients were reproduced to determine the contrast-to-noise ratio (CNR) and mean glandular dose (MGD). The parameters were also used to radiograph a CDMAM (version 3.4) phantom (Artinis Medical Systems, The Netherlands) for image threshold contrast evaluation. After that, different breast thicknesses were simulated with polymethylmethacrylate layers and various sets of exposure parameters were used in order to determine optimal radiographic parameters. For each simulated breast thickness, optimal beam quality was defined as giving a target CNR to reach the threshold contrast of CDMAM images for acceptable MGD. These results were used for adjustments in the automatic exposure control (AEC) by the maintenance team. Using optimized exposure parameters, clinical images of 63 patients (group 2) were evaluated as described above. Threshold contrast, CNR and MGD for such exposure parameters were also determined. Results showed that the proposed optimization method was effective for all breast thicknesses studied in phantoms. The best result was found for breasts of 75 mm. While in group 1 there was no detection of the 0.1 mm critical diameter detail with threshold contrast below 23%, after the optimization, detection occurred in 47.6% of the images. There was also an average MGD reduction of 7.5%. The clinical image quality criteria were attended in 91.7% for all breast thicknesses evaluated in both

  14. Botulinum toxin for treatment of glandular hypersecretory disorders.

    LENUS (Irish Health Repository)

    Laing, T A

    2012-02-03

    SUMMARY: The use of botulinum toxin to treat disorders of the salivary glands is increasing in popularity in recent years. Recent reports of the use of botulinum toxin in glandular hypersecretion suggest overall favourable results with minimal side-effects. However, few randomised clinical trials means that data are limited with respect to candidate suitability, treatment dosages, frequency and duration of treatment. We report a selection of such cases from our own department managed with botulinum toxin and review the current data on use of the toxin to treat salivary gland disorders such as Frey\\'s syndrome, excessive salivation (sialorrhoea), focal and general hyperhidrosis, excessive lacrimation and chronic rhinitis.

  15. Spatio-temporal imaging of the hemoglobin in the compressed breast with diffuse optical tomography

    Science.gov (United States)

    Boverman, Gregory; Fang, Qianqian; Carp, Stefan A.; Miller, Eric L.; Brooks, Dana H.; Selb, Juliette; Moore, Richard H.; Kopans, Daniel B.; Boas, David A.

    2007-07-01

    We develop algorithms for imaging the time-varying optical absorption within the breast given diffuse optical tomographic data collected over a time span that is long compared to the dynamics of the medium. Multispectral measurements allow for the determination of the time-varying total hemoglobin concentration and of oxygen saturation. To facilitate the image reconstruction, we decompose the hemodynamics in time into a linear combination of spatio-temporal basis functions, the coefficients of which are estimated using all of the data simultaneously, making use of a Newton-based nonlinear optimization algorithm. The solution of the extremely large least-squares problem which arises in computing the Newton update is obtained iteratively using the LSQR algorithm. A Laplacian spatial regularization operator is applied, and, in addition, we make use of temporal regularization which tends to encourage similarity between the images of the spatio-temporal coefficients. Results are shown for an extensive simulation, in which we are able to image and quantify localized changes in both total hemoglobin concentration and oxygen saturation. Finally, a breast compression study has been performed for a normal breast cancer screening subject, using an instrument which allows for highly accurate co-registration of multispectral diffuse optical measurements with an x-ray tomosynthesis image of the breast. We are able to quantify the global return of blood to the breast following compression, and, in addition, localized changes are observed which correspond to the glandular region of the breast.

  16. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors; Evaluacion de la influencia de los parametros que determinan la dosis glandular media en Mamografia utilizando diferentes detectores

    Energy Technology Data Exchange (ETDEWEB)

    Costa, K.; Nogueira, M. S., E-mail: katicostabh@gmail.com [Centro de Desenvolvimento da Tecnologia Nuclear, Pos-graduacao em Ciencias e Tecnologia das Radiacoes, Minerais e Materiais / CNEN, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  17. Evaluation of the influence of parameters that determine the mean glandular dose in mammography using different detectors

    International Nuclear Information System (INIS)

    Costa, K.; Nogueira, M. S.

    2015-10-01

    Full text: Mammography is a test used for early detection of breast cancer. The mean glandular dose (MGD) is dosimetric greatness accepted as indicative of carcinogenic risk induced by ionizing radiation in the breasts of women undergoing mammography exams. MGD value is estimated from the incident air kerma (k i), associated with conversion factors which depend on the half-value layer (HVL), the breast composition and thickness compressed breast. This study aims to evaluate the influence of the parameters used to determine the MGD using different measurement detectors. Measurements were performed on a Siemens Mammomat Model 300 Nova mammography equipment; this has the combinations Anode/Filter of Mo/Mo, Mo/Rh and W/Rh. Detectors used were the ionization chamber Model 10X6-6M manufactured by Radcal Co., two solid-state detectors, one Model AGMS-M manufactured by Radcal Co. and other Model Xi Mammo manufactured by UNFORS. The detectors measures were compared and the MGD value was estimated; differences between measurements and the reference values were higher in HVL and k i parameters. The results are displayed according to other published works. (Author)

  18. Investigation on location-dependent detectability of a small mass for digital breast tomosynthesis evaluation

    Science.gov (United States)

    Lee, Changwoo; Baek, Jongduk; Park, Subok

    2016-03-01

    Digital breast tomosynthesis (DBT) is an emerging imaging modality for improved breast cancer detection and diagnosis [1-5]. Numerous efforts have been made to find quantitative metrics associated with mammographic image quality assessment, such as the exponent β of anatomical noise power spectrum, glandularity, contrast noise ratio, etc. [6-8]. In addition, with the use of Fourier-domain detectability for a task-based assessment of DBT, a stationarity assumption on reconstructed image statistics was often made [9-11], resulting in the use of multiple regions-of-interest (ROIs) from different locations in order to increase sample size. While all these metrics provide some information on mammographic image characteristics and signal detection, the relationship between these metrics and detectability in DBT evaluation has not been fully understood. In this work, we investigated spatial-domain detectability trends and levels as a function of the number of slices Ns at three different ROI locations on the same image slice, where background statistics differ in terms of the aforementioned metrics. Detectabilities for the three ROI locations were calculated using multi-slice channelized Hotelling observers with 2D/3D Laguerre-Gauss channels. Our simulation results show that detectability levels and trends as a function of Ns vary across these three ROI locations. They also show that the exponent β, mean glandularity, and mean attenuation coefficient vary across the three ROI locations but they do not necessarily predict the ranking of detectability levels and trends across these ROI locations.

  19. Review of Dosimetric Methods for Mammography in the UK Breast Screening Programme

    International Nuclear Information System (INIS)

    Young, K.C.; Ramsdale, M.L.; Bignell, F.

    1998-01-01

    The two methods used to monitor dose in mammography in the UK Breast Screening Programme are reviewed. The first is the measurement of mean glandular dose to a standard breast. The second is the estimation of mean glandular dose for individual women using the X ray exposure factors. Neither method takes account of variations in breast composition and the effect of this on estimates of glandular dose are reported. Applying the standard breast model using PMMA resulted in substantial overestimates of breast doses for women with large compressed breast thicknesses because they tend to have low glandular content. Conversely the use of post-exposure data to estimate the MGDs in women attending screening with large breasts resulted in underestimates of their doses unless the relatively low levels of glandularity were taken into account. When estimating the MGDs for breasts of different sizes, it is important that the models and methods used take account of the strong variation in breast composition with compressed thickness. (author)

  20. Comparison of anode/filter combinations in digital mammography with respect to the average glandular dose

    International Nuclear Information System (INIS)

    Uhlenbrock, D.F.; Mertelmeier, Thomas

    2009-01-01

    To investigate the average glandular dose (AGD) applied for clinical digital mammograms acquired with the anode/filter combinations molybdenum/molybdenum (Mo/Mo), molybdenum/rhodium (Mo/Rh), and tungsten/rhodium (W/Rh). Using the method of Dance, the AGD was evaluated from the exposure data of 4867 digital mammograms at two sites equipped with a full-field digital mammography (FFDM) system based on an amorphous selenium detector. 1793 images were acquired and analyzed with Mo/Mo, 643 with Mo/Rh, and 2431 with W/Rh. In the Mo/Mo cases the mean compressed breast thickness was 46 ± 10 mm with an average AGD of 2.29 ± 1.31 mGy. For the Mo/Rh cases with a mean compressed thickness of 64 ± 9 mm, we obtained 2.76 ± 1.31 mGy. The W/Rh cases with a mean compressed thickness of 52 ± 13 mm resulted in 1.26 ± 0.44 mGy. The image quality was assessed as normal and adequate for diagnostic purposes in all cases. (orig.)

  1. Enhancement of lymphocyte proliferation by mouse glandular kallikrein.

    Science.gov (United States)

    Hu, Z Q; Murakami, K; Ikigai, H; Shimamura, T

    1992-03-01

    Mouse glandular kallikrein (mGK) strongly enhanced the spontaneous and mitogen-induced proliferation of lymphocytes. Both blast formation and 3H-TdR incorporation were dose-dependently enhanced at the same time many cells were killed. The enhancing activity was independent of EGF, because EGF-binding proteins (mGK-9 in mGK-6,9 mixture and mGK-13), renal kallikrein (mGK-6) and human kallikrein all displayed the same enhancement. A serine proteinase inhibitor, diisopropyl fluorophosphate, could block the enhancement by mGK. The new function suggests that mGK is important in the immune system as a regulatory molecule.

  2. Measurement of the radiation dose and assessment of the risk in mammography screening for early detection of cancer of the breast, in Israel

    International Nuclear Information System (INIS)

    Broisman, A.; Schlesinger, T.; Alfassi, Z. B.

    2011-01-01

    The mean glandular doses to samples of women attending for mammographic screening are measured routinely at screening centres in Israel. As at present, no detailed and systematic data have been collected regarding the average glandular dose in mammography screening procedures carried out in Israel for the last 20 y. Especially data are lacking related to the glandular dose (GD) involved in mammography with the new digital mammography systems. In this work, partial results of the measurements are presented to asses the radiation dose to the breast and to the glandular tissue within the Israeli national mammography programme updated to year 2009. (authors)

  3. Telomerase reverse transcriptase promoter mutations in glandular lesions of the urinary bladder.

    Science.gov (United States)

    Vail, Eric; Zheng, Xiaoyong; Zhou, Ming; Yang, Ximing; Fallon, John T; Epstein, Jonathan I; Zhong, Minghao

    2015-10-01

    Glandular lesions of the urinary bladder include a broad spectrum of entities ranging from completely benign to primary and secondary malignancies. The accurate diagnosis of these lesions is both important and challenging. Recently, studies suggest that telomerase reverse transcriptase (TERT) promoter mutations could be a biomarker for urothelial carcinoma (UC). We hypothesized that these mutations can distinguish UC with glandular differentiation from nephrogenic adenoma, primary adenocarcinoma of the urinary bladder (PAUB), or secondary malignancies. Twenty-five cases of benign glandular lesions (including nephrogenic adenoma); 29 cases of UC with glandular differentiation; 10 cases of PAUB; and 10 cases each of metastatic colon cancer, prostatic carcinoma, and carcinoma from Mullerian origin were collected. Slides were reviewed and selected to make sure the lesion was at least 10% to 20% of all tissue. Macrodissection was performed in some of cases, and genomic DNA was extracted from the tissue. Telomerase reverse transcriptase promoter mutations were determined by standard polymerase chain reaction sequencing. Twenty-one cases (72%) of UC with glandular differentiation were positive for TERT promoter mutations. However, none of the remaining cases (total 65 cases of benign lesions, PAUB, and metastatic carcinomas) was positive for TERT promoter mutation. Telomerase reverse transcriptase promoter mutations were highly associated with UC including UC with glandular differentiation but not other glandular lesions of bladder. Therefore, in conjunction with morphologic features, Immunohistochemistry stain profile, and clinical information, TERT promoter mutations could distinguish UC with glandular differentiation from other bladder glandular lesions. In addition, lack of TERT promoter mutations in primary adenocarcinoma of bladder suggests that this entity may have different origin or carcinogenesis from those of UC. Published by Elsevier Inc.

  4. Glandular dose and image quality control in mammography facilities with computerized radiography systems; Dose glandular e controle de qualidade da imagem em servicos de mamografia com sistema de radiografia computadorizada

    Energy Technology Data Exchange (ETDEWEB)

    Dantas, Marcelino Vicente de Almeida

    2010-07-01

    Breast cancer is the most common cancer among women, and early detection is critical to its diagnosis and treatment. To date, the most effective method for early detection of breast cancer has been x-ray mammography for which the screen/film (SF) technique has been the gold standard. However, even though SF combinations have been improved and optimized over the years for breast imaging, there are some critical limitations, including a narrow exposure range, image artifacts, film processing problems, and inflexibility in image processing and film management. In recent years, digital mammography has been introduced in cancer screening programmes with the screen/film techniques gradually being phased out. Computed radiography (CR), also commonly known as photostimulable phosphor (PSP) imaging or storage phosphor, employs reusable imaging plates and associated hardware and software to acquire and to display digital projection radiographs. In this work, a protocol model was tested for performing image quality control and average glandular dose (AGD) evaluation in 19 institutions with computed radiography systems for mammography. The protocol was validated through tests at the Laboratorio de Radioprotecao Aplicada a Mamografia (LARAM) from the Centro de Desenvolvimento da Tecnologia Nuclear (CDTN). The image quality visual evaluation of CDMAM phantom showed that 53% of the facilities were able to produce images of excellent quality. Furthermore, the automated evaluation of image quality, using the analyze software cdcom.exe, showed that 57% of the images were considered to be of good quality. The detector linearity test showed that the CR response is very linear, where 95% of facilities evaluated were considered to be compliant. For the image noise was found that only 20% of facilities are in agreement with the parameters established for this test. The average glandular doses, which patients may be getting to perform an examination, were below the action levels

  5. Results of a 2011 national questionnaire for investigation of mean glandular dose from mammography in Japan.

    Science.gov (United States)

    Asada, Y; Suzuki, S; Minami, K; Shirakawa, S

    2014-03-01

    Diagnostic reference levels (DRLs) for mammography have yet to be created in Japan. A national questionnaire investigation into radiographic conditions in Japan was carried out for the purpose of creating DRLs. Items investigated included the following: tube voltage; tube current; current-time product; source-image distance; craniocaudal view; automatic exposure control (AEC) settings; name of mammography unit; image receptor system (computed radiography (CR), flat panel detector (FPD), or film/screen (F/S)); and supported or unsupported monitor diagnosis (including monitor resolution). Estimation of the mean glandular dose (MGD) for mammography was performed and compared with previous investigations. The MGD was 1.58(0.48) mGy, which did not significantly differ from a 2007 investigation. In relation to image receptors, although no difference in average MGD values was observed between CR and FPD systems, F/S systems had a significantly decreased value compared to both CR and FPDs. Concerning digital systems (FPDs), the MGD value of the direct conversion system was significantly higher than the indirect conversion system. No significant difference in MGD value was evident concerning type of monitor diagnosis for either the CR or the FPD digital systems; however, hard copies were used more often in CR. No significant difference in the MGD value was found in relation to monitor resolution. This report suggests ways to lower the doses patients undergoing mammography receive in Japan, and serves as reference data for 4.2 cm compressed breast tissue of 50% composition DRLs. Furthermore, our findings suggest that further optimisation of FPD settings can promote a reduction in the MGD value.

  6. Diagnostic and therapeutic dilemma associated with atypical glandular cells on liquid-based cervical cytology.

    LENUS (Irish Health Repository)

    Chummun, K

    2012-12-01

    In 2008, the management of women in Ireland with atypical glandular cells changed to immediate referral to colposcopy. The optimal management of these women is unclear. A balance between the detection of occult disease and overtreatment is required.

  7. Normal and pathological breast, the histological basis

    Energy Technology Data Exchange (ETDEWEB)

    Guinebretiere, J.M. [Department of Pathology, Centre Rene-Huguenin, 35 rue Dailly, 92210 Saint Cloud (France)]. E-mail: jm.guinebretiere@stcloud-huguenin.org; Menet, E. [Department of Pathology, Centre Rene-Huguenin, 35 rue Dailly, 92210 Saint Cloud (France); Tardivon, A. [Department of Radiology, Institut Curie, 26 rue d' Ulm, 75248 Paris Cedex 5 (France); Cherel, P. [Department of Radiology, Centre Rene-Huguenin, 35 rue Dailly, 92210 Saint Cloud (France); Vanel, D. [Department of Diagnostic Radiology, Institut Gustave-Roussy, 39 rue Camille Desmoulins, 94805 Villejuif (France)

    2005-04-01

    Breast tissue is heterogeneous, associating connective and glandular structures, which grow and change cyclically under hormonal regulation. Hormones are also thought to be the main determinant of the major benign and malignant pathologies encountered in the breast. Benign lesions are more frequent and fibrocystic changes are by far the most common among them. They usually associate different entities (adenosis, fibrosis, cysts and hyperplasia) but vary in intensity and extension. Thus, their clinical and radiographic presentation is extremely different from one patient to another. Adenofibroma is the most frequent tumour. It also undergoes modifications according to hormonal conditions. About 90% of malignant tumours are primary carcinoma. The incidence of intra-ductal carcinoma has risen dramatically since the development of screening because of its ability to induce calcification. Two mechanisms could be involved in the formation of calcification: one active (tumour cell secretion of vesicles), the other passive (necrotic cell fragments are released). Invasive carcinoma comprises numerous histological types. Stromal reactions essentially determines their shape: a fibrous reaction commonly found in ductal carcinoma creates a stellate lesion while other stroma, inflammatory (medullary carcinoma), vascular (papillary carcinoma) or mucinous determine nodular lesions whose borders push the surrounding tissue. The histological features which give rise to the radiographic pattern will be emphasised.

  8. SU-C-209-07: Phantoms for Digital Breast Tomosynthesis Imaging System Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jacobson, D; Liu, Y [Medical College of Wisconsin, Milwaukee, WI (United States)

    2016-06-15

    Purpose: Digital Breast Tomosynthesis (DBT) is gaining importance in breast imaging. There is a need for phantoms that can be used for image evaluation and comparison. Existing commercially available phantoms for DBT are expensive and may lack clinically relevant test objects. The purpose of this study is to develop phantoms for DBT evaluation. Methods Four phantoms have been designed and constructed to assess the image quality (IQ) of two DBT systems. The first contains a spiral of 0.3 mm SiC beads in gelatin to measure the tomographic slice thickness profile and uniformity of coverage in a series of tomographic planes. The second contains simulated tumors inclined with respect to the phantom base to assess tomographic image quality. The third has a tilted array of discs with varying contrast and diameter. This phantom was imaged alone and in a stack of TE slabs giving 2 to 10 cm thickness. The fourth has a dual wedge of glandular and adipose simulating materials. One wedge contains discs with varying diameter and thickness; the other supports a mass with six simulated spicules of varying size and a cluster of simulated calcifications. The simulated glandular tissue material varies between 35 and 100% of the total thickness (5.5 cm). Results: All phantoms were scanned successfully. The best IQ comparison was achieved with the dual wedge phantom as demonstrated by the spiculated mass and calcifications. Images were evaluated by two radiologists and one physicist. The projection images and corresponding set of tomographic planes were comparable and the synthesized projection images were inferior to the projection images for both systems. Conclusion: Four phantoms were designed, constructed and imaged on two DBT systems. They successfully demonstrated performance differences between two systems, and between true and synthesized projection images. Future work will incorporate these designs into a single phantom.

  9. Mineral nutrient uptake from prey and glandular phosphatase activity as dual test of carnivory in semidesert plants with glandular leaves suspected of carnivory

    Czech Academy of Sciences Publication Activity Database

    Plachno, B.J.; Adamec, Lubomír; Huet, H.

    2009-01-01

    Roč. 104, č. 4 (2009), s. 649-654 ISSN 0305-7364 Institutional research plan: CEZ:AV0Z60050516 Keywords : mineral nutrient uptake * phosphatases * glandular leaves Subject RIV: EF - Botanics Impact factor: 3.501, year: 2009

  10. [Breast tomosynthesis: a new tool for diagnosing breast cancer].

    Science.gov (United States)

    Martínez Miravete, P; Etxano, J

    2015-01-01

    Breast cancer continues to be the most common malignant tumor in women in occidental countries. Mammography is currently the technique of choice for screening programs; however, although it has been widely validated, mammography has its limitations, especially in dense breasts. Breast tomosynthesis is a revolutionary advance in the diagnosis of breast cancer. It makes it possible to define lesions that are occult in the glandular tissue and therefore to detect breast tumors that are impossible to see on conventional mammograms. In considering the combined use of mammography and tomosynthesis, many factors must be taken into account apart from cancer detection; these include additional radiation, the recall rate, and the time necessary to carry out and interpret the two tests. In this article, we review the technical principles of tomosynthesis, it main uses, and the future perspective for this imaging technique. Copyright © 2013 SERAM. Published by Elsevier España, S.L.U. All rights reserved.

  11. Ceramic and polymeric devices for breast brachytherapy - Mammographic and CT response

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2009-01-01

    The present research investigates the radiological visibility of ceramic and polymeric devices implanted in breast phantom (in vitro) for future applications in brachytherapy treatments. The main research goal is to investigate the viability of monitoring ceramic and polymeric devices, in vitro based on simple methods of radiological diagnostic, maintaining the easiest access to the population, represented by the conventional X-ray and mammography. The methodology involves the processing of ceramic devices constituted by bioglasses of Sm, SmBa, Ho, HoBa and the production of polymeric devices, such as polymeric membranes incorporating Ho e HoBa. Contrast agent of Barium was introduced in the syntheses of those devices to improve the radiological visibility in breast equivalent-tissue (TE) phantom. The breast phantom is constituted of glandular, adipose and skin TE, reproducing a 5 cm compressed real breast. In the compressed breast phantom, all types of ceramic and polymeric devices were implanted side by side. Radiological images were generated through X-ray equipment, mammography and computerized tomography (TC), for the samples implanted in the compressed breast phantom. The results show that SmBa and HoBa seeds on breast phantom presented suitable radiological visibility, on all the radiological diagnostic methods. However, the X-rays radiological visibility of Sm seeds without contrast was discreet. On mammography and TC images, it was not possible to identify those seeds, because the same ones were degraded after two months immersed in the glandular TE, after placed on the phantom. The Ho seeds were identified on all radiological diagnostic images, although non contrast agent in its constitution was added. However, the holmium polymeric membranes in direct contact with TE did not show Xray radiological visibility. However, the polymeric membranes of HoBa in the same conditions presented efficient X-rays radiological response. For mammography and TC methods

  12. Optimization of Tomosynthesis Imaging for Improved Mass and Microcalcification Detection in the Breast

    Science.gov (United States)

    2009-04-01

    wall to nipple distance, breast thickness, and breast glandularity have been taken into account. We have generated and evaluated scatter components for...tion by use of these algorithms in their discrete forms. As men - tioned above, the BPF and MDFBP algorithms can reconstruct the image on the

  13. Recent decline in age at breast development: the Copenhagen Puberty Study

    DEFF Research Database (Denmark)

    Aksglaede, Lise; Sørensen, Kaspar; Petersen, Jørgen H

    2009-01-01

    cohorts. RESULTS: Onset of puberty, defined as mean estimated age at attainment of glandular breast tissue (Tanner breast stage 2+), occurred significantly earlier in the 2006 cohort (estimated mean age: 9.86 years) when compared with the 1991 cohort (estimated mean age: 10.88 years). The difference...

  14. Phantoms for quality control procedures in digital breast tomosynthesis: dose assessment

    NARCIS (Netherlands)

    Bouwman, R. W.; Diaz, O.; van Engen, R. E.; Young, K. C.; den Heeten, G. J.; Broeders, M. J. M.; Veldkamp, W. J. H.; Dance, D. R.

    2013-01-01

    The recent introduction of digital breast tomosynthesis into clinical practice requires quality control procedures. In this study we have investigated whether the assessment of the average glandular dose for modelled standard breasts can be performed using a combination of polymethyl methacrylate

  15. Caracterização e ontogenia dos tricomas glandulares de Ocimum selloi Benth. - Lamiaceae Characterization and ontogeny of the glandular trichomes of Ocimum selloi Benth. (Lamiaceae

    Directory of Open Access Journals (Sweden)

    Letícia de Almeida Gonçalves

    2010-12-01

    Full Text Available Ocimum selloi Benth. (Lamiaceae é uma espécie nativa da América do Sul e na medicina popular tem sido usada devido suas propriedades analgésica, anti-inflamatória e antiespasmódica. O objetivo do presente trabalho foi identificar os tipos de tricomas glandulares que ocorrem nos órgãos vegetativos e reprodutivos de O. selloi e determinar a ontogenia desses tricomas. Ramos laterais em início de formação, folhas totalmente expandidas, flores em diferentes estádios de diferenciação, amostras de caule e do eixo das inflorescências foram analisados em microscopias de luz e eletrônica de varredura. Tricomas glandulares do tipo peltado e capitado subséssil foram observados no caule, nas folhas, no eixo da inflorescência e na superfície adaxial das sépalas. Nas sépalas foi encontrado, além dos tricomas secretores peltados e capitados subsésseis, o tricoma glandular capitado pedunculado. A ontogenia inicia-se com a expansão de uma célula protodérmica que, de acordo com a seqüência de divisões periclinais e anticlinais (ora simétricas, ora assimétricas, dá origem aos tricomas. A diferenciação dos tricomas glandulares peltados e capitados não é sincrônica e ocorre muito cedo no desenvolvimento da folha, do caule e do eixo floral.Ocimum selloi Benth. (Lamiaceae is native to South America and in traditional medicine has been used due to its analgesic, anti-inflammatory, and antispasmodic properties. The aim of this study was to identify the types of glandular trichomes that occur on the vegetative and reproductive organs of O. selloi and to determine trichome ontogeny. Lateral branches at the initial formation phase, fully opened leaves, flowers at different differentiation stages, and stem and inflorescence axes were analyzed under light and scanning electron microscopy. Glandular trichomes of the peltate and subsessile capitate types were observed on the stem, leaves, inflorescence axis and the adaxial surface of the

  16. Higher glandular trichome density in tomato leaflets and repellence to spider mites

    International Nuclear Information System (INIS)

    Maluf, Wilson Roberto; Inoue, Irene Fumi; Ferreira, Raphael de Paula Duarte; Gomes, Luiz Antonio Augusto; Castro, Evaristo Mauro de; Cardoso, Maria das Gracas

    2007-01-01

    The objective of this work was to evaluate the feasibility of selection for higher glandular trichome densities, as an indirect criterion of selection for increasing repellence to spider mites Tetranychus urticae, in tomato populations derived from an interspecific cross between Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Trichome densities were evaluated in 19 genotypes, including 12 from advanced backcross populations, derived from the original cross L. esculentum x L. hirsutum var. glabratum PI 134417. Counts were made both on the adaxial and abaxial leaf surfaces, and trichomes were classified into glandular types IV and VI, other glandular types (types I+VII), and nonglandular types. Mite repellence was measured by distances walked by mites onto the tomato leaf surface after 20, 40 and 60 min. Spider mite repellence biotests indicated that higher densities of glandular trichomes (especially type VI) decreased the distances walked by the mites onto the tomato leaf surface. Selection of plants with higher densities of glandular trichomes can be an efficient criterion to obtain tomato genotypes with higher resistance (repellence) to spider mites. (author)

  17. Clinically relevant morphological structures in breast cancer represent transcriptionally distinct tumor cell populations with varied degrees of epithelial-mesenchymal transition and CD44+CD24- stemness.

    Science.gov (United States)

    Denisov, Evgeny V; Skryabin, Nikolay A; Gerashchenko, Tatiana S; Tashireva, Lubov A; Wilhelm, Jochen; Buldakov, Mikhail A; Sleptcov, Aleksei A; Lebedev, Igor N; Vtorushin, Sergey V; Zavyalova, Marina V; Cherdyntseva, Nadezhda V; Perelmuter, Vladimir M

    2017-09-22

    Intratumor morphological heterogeneity in breast cancer is represented by different morphological structures (tubular, alveolar, solid, trabecular, and discrete) and contributes to poor prognosis; however, the mechanisms involved remain unclear. In this study, we performed 3D imaging, laser microdissection-assisted array comparative genomic hybridization and gene expression microarray analysis of different morphological structures and examined their association with the standard immunohistochemistry scorings and CD44 + CD24 - cancer stem cells. We found that the intratumor morphological heterogeneity is not associated with chromosomal aberrations. By contrast, morphological structures were characterized by specific gene expression profiles and signaling pathways and significantly differed in progesterone receptor and Ki-67 expression. Most importantly, we observed significant differences between structures in the number of expressed genes of the epithelial and mesenchymal phenotypes and the association with cancer invasion pathways. Tubular (tube-shaped) and alveolar (spheroid-shaped) structures were transcriptionally similar and demonstrated co-expression of epithelial and mesenchymal markers. Solid (large shapeless) structures retained epithelial features but demonstrated an increase in mesenchymal traits and collective cell migration hallmarks. Mesenchymal genes and cancer invasion pathways, as well as Ki-67 expression, were enriched in trabecular (one/two rows of tumor cells) and discrete groups (single cells and/or arrangements of 2-5 cells). Surprisingly, the number of CD44 + CD24 - cells was found to be the lowest in discrete groups and the highest in alveolar and solid structures. Overall, our findings indicate the association of intratumor morphological heterogeneity in breast cancer with the epithelial-mesenchymal transition and CD44 + CD24 - stemness and the appeal of this heterogeneity as a model for the study of cancer invasion.

  18. Digital breast tomosynthesis

    International Nuclear Information System (INIS)

    Haegele, Julian; Barkhausen, Joerg; Pursche, Telja; Schaefer, Fritz K.W.

    2015-01-01

    In digital breast tomosynthesis a digital tomographic data set with a very high spatial resolution is reconstructed from low-dose projections collected over a limited rotation angle. This allows a very detailed assessment of e. g. masses and architectural distortions. The average glandular dose is comparable to 2 D mammography. First clinical studies demonstrated that tomosynthesis is able to supply important additional information in suspicious mammographic findings. In comparison to projection mammography, tomosynthesis shows an at least comparable diagnostic accuracy. In everyday practice, tomosynthesis is currently mostly used for further evaluation of suspicious findings in mammography.

  19. A statistically defined anthropomorphic software breast phantom

    International Nuclear Information System (INIS)

    Lau, Beverly A.; Reiser, Ingrid; Nishikawa, Robert M.; Bakic, Predrag R.

    2012-01-01

    Purpose: Digital anthropomorphic breast phantoms have emerged in the past decade because of recent advances in 3D breast x-ray imaging techniques. Computer phantoms in the literature have incorporated power-law noise to represent glandular tissue and branching structures to represent linear components such as ducts. When power-law noise is added to those phantoms in one piece, the simulated fibroglandular tissue is distributed randomly throughout the breast, resulting in dense tissue placement that may not be observed in a real breast. The authors describe a method for enhancing an existing digital anthropomorphic breast phantom by adding binarized power-law noise to a limited area of the breast. Methods: Phantoms with (0.5 mm) 3 voxel size were generated using software developed by Bakic et al. Between 0% and 40% of adipose compartments in each phantom were replaced with binarized power-law noise (β = 3.0) ranging from 0.1 to 0.6 volumetric glandular fraction. The phantoms were compressed to 7.5 cm thickness, then blurred using a 3 × 3 boxcar kernel and up-sampled to (0.1 mm) 3 voxel size using trilinear interpolation. Following interpolation, the phantoms were adjusted for volumetric glandular fraction using global thresholding. Monoenergetic phantom projections were created, including quantum noise and simulated detector blur. Texture was quantified in the simulated projections using power-spectrum analysis to estimate the power-law exponent β from 25.6 × 25.6 mm 2 regions of interest. Results: Phantoms were generated with total volumetric glandular fraction ranging from 3% to 24%. Values for β (averaged per projection view) were found to be between 2.67 and 3.73. Thus, the range of textures of the simulated breasts covers the textures observed in clinical images. Conclusions: Using these new techniques, digital anthropomorphic breast phantoms can be generated with a variety of glandular fractions and patterns. β values for this new phantom are comparable

  20. A minimum spanning forest based classification method for dedicated breast CT images

    International Nuclear Information System (INIS)

    Pike, Robert; Sechopoulos, Ioannis; Fei, Baowei

    2015-01-01

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging

  1. Polyvinyl chloride plastisol breast phantoms for ultrasound imaging.

    Science.gov (United States)

    de Carvalho, Isabela Miller; De Matheo, Lucas Lobianco; Costa Júnior, José Francisco Silva; Borba, Cecília de Melo; von Krüger, Marco Antonio; Infantosi, Antonio Fernando Catelli; Pereira, Wagner Coelho de Albuquerque

    2016-08-01

    Ultrasonic phantoms are objects that mimic some features of biological tissues, allowing the study of their interactions with ultrasound (US). In the diagnostic-imaging field, breast phantoms are an important tool for testing performance and optimizing US systems, as well as for training medical professionals. This paper describes the design and manufacture of breast lesions by using polyvinyl chloride plastisol (PVCP) as the base material. Among the materials available for this study, PVCP was shown to be stable, durable, and easy to handle. Furthermore, it is a nontoxic, nonpolluting, and low-cost material. The breast's glandular tissue (image background) was simulated by adding graphite powder with a concentration of 1% to the base material. Mixing PVCP and graphite powder in differing concentrations allows one to simulate lesions with different echogenicity patterns (anechoic, hypoechoic, and hyperechoic). From this mixture, phantom materials were obtained with speed of sound varying from 1379.3 to 1397.9ms(-1) and an attenuation coefficient having values between 0.29 and 0.94dBcm(-1) for a frequency of 1MHz at 24°C. A single layer of carnauba wax was added to the lesion surface in order to evaluate its applicability for imaging. The images of the phantoms were acquired using commercial ultrasound equipment; a specialist rated the images, elaborating diagnoses representative of both benign and malignant lesions. The results indicated that it was possible to easily create a phantom by using low-cost materials, readily available in the market and stable at room temperature, as the basis of ultrasonic phantoms that reproduce the image characteristics of fatty breast tissue and typical lesions of the breast. Copyright © 2016 Elsevier B.V. All rights reserved.

  2. Cadmium induced changes in subcellular glutathione contents within glandular trichomes of Cucurbita pepo L.

    Science.gov (United States)

    Kolb, Dagmar; Müller, Maria; Zellnig, Günther; Zechmann, Bernd

    2010-07-01

    Plants cope with cadmium (Cd) stress by complexation with phytochelatins (Pc), metallothioneins and glutathione and sequestration within vacuoles. Especially glutathione was found to play a major role in Cd detoxification as Cd shows a high binding affinity towards thiols and as glutathione is a precursor for Pc synthesis. In the present study, we have used an immunohistochemical approach combined with computer-supported transmission electron microscopy in order to measure changes in the subcellular distribution of glutathione during Cd-stress in mesophyll cells and cells of different glandular trichomes (long and short stalked) of Cucurbita pepo L. subsp. pepo var. styriaca GREB: . Even though no ultrastructural alterations were observed in leaf and glandular trichome cells after the treatment of plants with 50 microM cadmium chloride (CdCl(2)) for 48 h, all cells showed a large decrease in glutathione contents. The strongest decrease was found in nuclei and the cytosol (up to 76%) in glandular trichomes which are considered as a major side of Cd accumulation in leaves. The ratio of glutathione between the cytosol and nuclei and the other cell compartments was strongly decreased only in glandular trichomes (more than 50%) indicating that glutathione in these two cell compartments is especially important for the detoxification of Cd in glandular trichomes. Additionally, these data indicate that large amounts of Cd are withdrawn from nuclei during Cd exposure. The present study gives a detailed insight into the compartment-specific importance of glutathione during Cd exposure in mesophyll cells and glandular trichomes of C. pepo L. plants.

  3. Papel dos tricomas glandulares da folha do tomateiro na oviposição de Tuta absoluta Role of tomato leaf glandular trichomes on oviposition of Tuta absoluta

    Directory of Open Access Journals (Sweden)

    Elsa Gilardón

    2001-03-01

    Full Text Available Os tricomas glandulares presentes nas folhas e ramos das plantas do gênero Lycopersicon são responsáveis pela secreção de metabólitos de diferentes naturezas. A presença de alguns desses compostos tem sido associada à resistência do tomate a diferentes insetos. A traça-do-tomateiro, Tuta absoluta (Meyrick, é uma das pragas mais nocivas da América do Sul. O adulto oviposita sobre as folhas do tomate e suas larvas abrem galerias no mesófilo das folhas, ramos, flores e frutos. As espécies silvestres do tomate conservam a capacidade de biossintetizar compostos químicos que lhes conferem resistência a esta praga. No presente trabalho, foi avaliada a preferência para oviposição desse inseto sobre folhas com e sem tricomas glandulares de L. esculentum (Mill. cv. Uco Plata, suscetível, e de L. hirsutum f. glabratum (Mull. PI 134417, espécie silvestre afim ao tomate, e resistente à traça. Os resultados sugerem que as fêmeas ovipositam indistintamente sobre as folhas de ambas espécies, independentemente da presença, ou não, dos tricomas glandulares. E a presença destes e de seus exsudatos não têm efeito inibidor na oviposição do inseto.In the genus Lycopersicon, different metabolites are secreted by the glandular trichomes of leaves and stems. These compounds have been associated to different tomato pests resistance. The South American tomato pinworm, Tuta absoluta (Meyrick, is one of the most harmful pests in South America. The females oviposit on tomato leaves and the larvae mine the leaf mesophyl, stems, flowers and fruits. Some wild accessions of Lycopersicon keep their capacity to synthesize allelochemicals that protect them from the pest. In this paper a comparison was made between the tomato pinworm oviposition on leaves with and without trichomes of L. esculentum (Mill. cv. Uco Plata, a susceptible cultivar, and L. hirsutum f. glabratum (Mull. PI 134417, a resistant wild accession. Results suggest that the female

  4. Diagnosis of breast cancer using diffuse optical spectroscopy from 500 to 1600 nm: a comparison of classification methods

    NARCIS (Netherlands)

    Nachabe, R.; Evers, D.; Hendriks, B.H.W.; Lucassen, G.W.; Van der Voort, M.; Wesseling, J.; Rutgers, E. J.; Vrancken Peeters, M.J.; Hage, J.A.van der; Oldenbeng, H.S.; Ruers, T.

    2011-01-01

    We report on the use of diffuse optical spectroscopy analysis of breast spectra acquired in the wavelength range from 500 to 1600 nm with a fiber optic probe. A total of 102 ex vivo samples of five different breast tissue types, namely adipose, glandular, fibroadenoma, invasive carcinoma and ductal

  5. Diagnosis of breast cancer using diffuse optical spectroscopy from 500 to 1600 nm: comparison of classification methods

    NARCIS (Netherlands)

    Nachabé, Rami; Evers, Daniel; Evers, Daniel J.; Hendriks, Benno H.W.; Lucassen, Gerald W.; Lucassen, Gerald; van der Voort, Marjolein; Rutgers, Emiel J.; Vrancken Peeters, Marie-Jeanne; van der Hage, Jos A.; Oldenburg, Hester S.; Wesseling, Jelle; Ruers, Theo J.M.

    2011-01-01

    We report on the use of diffuse optical spectroscopy analysis of breast spectra acquired in the wavelength range from 500 to 1600 nm with a fiber optic probe. A total of 102 ex vivo samples of five different breast tissue types, namely adipose, glandular, fibroadenoma, invasive carcinoma, and ductal

  6. Evolution of the excess absolute risk (EAR) in the Valencian breast cancer screening programme

    International Nuclear Information System (INIS)

    Ferrer, S.; Ramos, M.; Villaescusa, J. I.; Verdu, G.; Salas, M. D.; Cuevas, M. D.

    2004-01-01

    Breast cancer is one of the most frequent diseases in women, with a high incidence rate. The best fight against the breast cancer is the early detection by menas of mammograms in a screening programme. The Valencian Breast Cancer Screening Programme (VBCSP) started at 1992, and it is composed of twenty-two mammography units. The programme is targeted towards asympotomatic women dfrom 45 to 69 years old, but this screening has a negative influence in the studied woman, whatever the diagnosis was. By means of MCNP-4c2 Monte Carlo code, some conversion factors from air kerma air kerma to glandular dose have been developed. Different breast woamn models, according to the Valencian brest anathomy (taking into account the relation breast radius / breast compression thickness obtained from real samples, have been simulated in order to obtain the glandular breast dose values. Quality control parameters as ESAK values were also employed for developing the methods. The conversion factors give a simple and fast wasy to obtain the mean glandular dose from mammography exposition parameters. The glandular dose has been also calculated following the European Protocol on Dosimetry in order to compare the results of the new methodology. Four sample populations of 100 omen from each uunit of the VBCSP have been taken innnn order to estimate the mean glandular dose and the associated excess absolute risk (EAR). Once the doses for each woman from the samples are obtained and according to the age of them, the EAR value for each sample has been determinated following the UNSCEAR 2000 projection risk model, which takes into account the characteristics of the Valencian population and gives the EAR for radio-induced breast cancer. The results have been calculated and compared by means of the ASQRAD software, but with an older risk projection model, the UNSCEAR 1994. Once the four sample average EAR have been calculated, the evolution of the induced risk in the Valencian Breast Cancer

  7. Phenylpropanoid biosynthesis in leaves and glandular trichomes of basil (Ocimum basilicum L.).

    Science.gov (United States)

    Deschamps, Cícero; Simon, James E

    2010-01-01

    Basil (Ocimum basilicum L.) essential oil phenylpropenes are synthesized and accumulate in peltate glandular trichomes and their content and composition depend on plant developmental stage. Studies on gene expression and enzymatic activity indicate that the phenylpropene biosynthetic genes are developmentally regulated. In this study, the methylchavicol accumulation in basil leaves and the enzyme activities and gene expression of both chavicol O-methyltransferase (CVOMT) and eugenol O-methyltransferase (EOMT) were investigated in all leaves at four plant developmental stages. Methylchavicol accumulation decreased over time as leaves matured. There was a significant correlation between methylchavicol accumulation and CVOMT (r(2) = 0.88) enzyme activity, suggesting that the levels of biosynthetic enzymes control the essential oil content. CVOMT and EOMT transcript expression levels, which decreased with leaf age, followed the same pattern in both whole leaves and isolated glandular trichomes, providing evidence that CVOMT transcript levels are developmentally regulated in basil glandular trichomes themselves and that differences in CVOMT expression observed in whole leaves are not solely the result of differences in glandular trichome density.

  8. Honey bee males and queens use glandular secretions to enhance sperm viability before and after storage

    DEFF Research Database (Denmark)

    Den Boer, Susanne Petronella A; Boomsma, Jacobus Jan; Baer, Boris

    2009-01-01

    Internal fertilization requires live sperm to be transferred from male to female before egg fertilization. Both males and females assist the insemination process by providing sperm with glandular secretions, which have been inferred to contain subsets of proteins that maintain sperm viability. He...

  9. Severe glandular tularemia in a patient treated with anti-tumour necrosis factor for psoriatic arthritis

    Directory of Open Access Journals (Sweden)

    Ruxandra Calin

    2017-07-01

    Full Text Available A case of severe glandular tularemia in a patient receiving anti-tumour necrosis factor (TNF therapy is reported here. The patient required prolonged treatment with doxycycline–ciprofloxacin due to early relapse after ciprofloxacin was stopped. Tularemia may have a more severe course in patients receiving anti-TNF. This may thus be an indication for more aggressive treatment.

  10. A Stochastic Polygons Model for Glandular Structures in Colon Histology Images.

    Science.gov (United States)

    Sirinukunwattana, Korsuk; Snead, David R J; Rajpoot, Nasir M

    2015-11-01

    In this paper, we present a stochastic model for glandular structures in histology images of tissue slides stained with Hematoxylin and Eosin, choosing colon tissue as an example. The proposed Random Polygons Model (RPM) treats each glandular structure in an image as a polygon made of a random number of vertices, where the vertices represent approximate locations of epithelial nuclei. We formulate the RPM as a Bayesian inference problem by defining a prior for spatial connectivity and arrangement of neighboring epithelial nuclei and a likelihood for the presence of a glandular structure. The inference is made via a Reversible-Jump Markov chain Monte Carlo simulation. To the best of our knowledge, all existing published algorithms for gland segmentation are designed to mainly work on healthy samples, adenomas, and low grade adenocarcinomas. One of them has been demonstrated to work on intermediate grade adenocarcinomas at its best. Our experimental results show that the RPM yields favorable results, both quantitatively and qualitatively, for extraction of glandular structures in histology images of normal human colon tissues as well as benign and cancerous tissues, excluding undifferentiated carcinomas.

  11. Digital mammography screening: average glandular dose and first performance parameters

    International Nuclear Information System (INIS)

    Weigel, S.; Girnus, R.; Czwoydzinski, J.; Heindel, W.; Decker, T.; Spital, S.

    2007-01-01

    Purpose: The Radiation Protection Commission demanded structured implementation of digital mammography screening in Germany. The main requirements were the installation of digital reference centers and separate evaluation of the fully digitized screening units. Digital mammography screening must meet the quality standards of the European guidelines and must be compared to analog screening results. We analyzed early surrogate indicators of effective screening and dosage levels for the first German digital screening unit in a routine setting after the first half of the initial screening round. Materials and Methods: We used three digital mammography screening units (one full-field digital scanner [DR] and two computed radiography systems [CR]). Each system has been proven to fulfill the requirements of the National and European guidelines. The radiation exposure levels, the medical workflow and the histological results were documented in a central electronic screening record. Results: In the first year 11,413 women were screened (participation rate 57.5 %). The parenchymal dosages for the three mammographic X-ray systems, averaged for the different breast sizes, were 0.7 (DR), 1.3 (CR), 1.5 (CR) mGy. 7 % of the screened women needed to undergo further examinations. The total number of screen-detected cancers was 129 (detection rate 1.1 %). 21 % of the carcinomas were classified as ductal carcinomas in situ, 40 % of the invasive carcinomas had a histological size ≤ 10 mm and 61 % < 15 mm. The frequency distribution of pT-categories of screen-detected cancer was as follows: pTis 20.9 %, pT1 61.2 %, pT2 14.7 %, pT3 2.3 %, pT4 0.8 %. 73 % of the invasive carcinomas were node-negative. (orig.)

  12. The effect of skin thickness determined using breast CT on mammographic dosimetry

    International Nuclear Information System (INIS)

    Huang Shihying; Boone, John M.; Yang, Kai; Kwan, Alexander L. C.; Packard, Nathan J.

    2008-01-01

    The effect of breast skin thickness on dosimetry in mammography was investigated. Breast computed tomography (CT) acquisition techniques, combined with algorithms designed for determining specific breast metrics, were useful for estimating skin thickness. A radial-geometry edge detection scheme was implemented on coronal reconstructed breast CT (bCT) images to measure the breast skin thickness. Skin thickness of bilateral bCT volume data from 49 women and unilateral bCT volume data from 2 women (10 healthy women and 41 women with BIRADS 4 and 5 diagnoses) was robustly measured with the edge detection scheme. The mean breast skin thickness (±inter-breast standard deviation) was found to be 1.45±0.30 mm. Since most current published normalized glandular dose (D gN ) coefficients are based on the assumption of a 4-mm breast skin thickness, the D gN values computed with Monte Carlo techniques will increase up to 18% due to the thinner skin layers (e.g., 6-cm 50% glandular breast, 28 kVp Mo-Mo spectrum). The thinner skin dimensions found in this study suggest that the current D gN values used for mammographic dosimetry lead to a slight underestimate in glandular dose

  13. A study of breast composition using radiographic techniques

    International Nuclear Information System (INIS)

    Noriah Jamal

    2005-01-01

    Accurate knowledge of breast composition is fundamental to the diagnosis and treatment of breast diseases. The goal of the research described in this thesis is to develop a system of experimental methods and theoretical models for studying breast composition using radiographic techniques. This research is divided into three parts. In part one, a technique based on the decomposition of breast components was developed and validated under laboratory conditions through the measurement of mastectomy specimen composition. The technique used double-exposure dual energy subtraction microradiography in conjunction with computed radiography in a five steps sequence, namely; a specimen was exposed at low and high energies alternately, followed by image registration, image subtraction and subsequent analysis of the subtracted image. The technique was then applied to quantify composition of mastectomy specimens. In part two, a quantitative assessment technique of breast density developed using MATLAB based image processing of digital mammograms. A comparison of breast density, classified by computer and subjective evaluation based on Tabar's patterns, was carried out. Inter-observer variations were analysed. In part three, a technique to estimate breast glandularity using phantom attenuation was developed and was used to estimate breast density for a large population sample. The difference in breast glandularity between three ethnic groups was tested for significance using the nonparametric Kruskal-Wallis test. This part also included an assessment of mammographic mean glandular dose using phantom-based and patient-based methods. Results from part 1 showed that in the double-exposure dual energy microradiography, the resulting fibroglandular tissue area was in 90.3 % agreement with the corresponding manually delineated areas by radiologists. In part 2 the results of computerised assessment of breast density from digitised mammograms correlated well (r 2 =0.92) with the

  14. Estimation of the average glandular dose on a team of tomosynthesis; Estimacion de la dosis glandular media en un equipo de tomosintesis

    Energy Technology Data Exchange (ETDEWEB)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-07-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  15. Localization of a defensive volatile 4-hydroxy-4-methylpentan-2-one in the capitate glandular trichomes of Oenothera glazioviana

    Institute of Scientific and Technical Information of China (English)

    Yanyun Tan; Desen Li; Juan Hua; Shihong Luo; Yan Liu; Shenghong Li

    2017-01-01

    Glandular trichomes of plants produce a wide variety of secondary metabolites which are considered as major defensive chemicals. The capitate glandular trichomes of Oenothera glazioviana (Onagraceae) were collected with laser microdissection and analyzed by gas chromatography-mass spectrometry. The volatile compound 4-hydroxy-4-methylpentan-2-one (1) was identified. We found that compound 1 displays antimicrobial, insecticidal, and phytotoxic activities. These results suggest that compound 1 might function as a defensive compound in the capitate glandular trichomes of O. glazioviana against pathogens, insect herbivores, and presumably competitive plants as well.

  16. Localization of a defensive volatile 4-hydroxy-4-methylpentan-2-one in the capitate glandular trichomes of Oenothera glazioviana

    Directory of Open Access Journals (Sweden)

    Yanyun Tan

    2017-06-01

    Full Text Available Glandular trichomes of plants produce a wide variety of secondary metabolites which are considered as major defensive chemicals. The capitate glandular trichomes of Oenothera glazioviana (Onagraceae were collected with laser microdissection and analyzed by gas chromatography–mass spectrometry. The volatile compound 4-hydroxy-4-methylpentan-2-one (1 was identified. We found that compound 1 displays antimicrobial, insecticidal, and phytotoxic activities. These results suggest that compound 1 might function as a defensive compound in the capitate glandular trichomes of O. glazioviana against pathogens, insect herbivores, and presumably competitive plants as well.

  17. Higher glandular trichome density in tomato leaflets and repellence to spider mites Alta densidade de tricomas glandulares em tomateiro e aumento da repelência a ácaros rajados

    Directory of Open Access Journals (Sweden)

    Wilson Roberto Maluf

    2007-09-01

    Full Text Available The objective of this work was to evaluate the feasibility of selection for higher glandular trichome densities, as an indirect criterion of selection for increasing repellence to spider mites Tetranychus urticae, in tomato populations derived from an interspecific cross between Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Trichome densities were evaluated in 19 genotypes, including 12 from advanced backcross populations, derived from the original cross L. esculentum x L. hirsutum var. glabratum PI 134417. Counts were made both on the adaxial and abaxial leaf surfaces, and trichomes were classified into glandular types IV and VI, other glandular types (types I+VII, and nonglandular types. Mite repellence was measured by distances walked by mites onto the tomato leaf surface after 20, 40 and 60 min. Spider mite repellence biotests indicated that higher densities of glandular trichomes (especially type VI decreased the distances walked by the mites onto the tomato leaf surface. Selection of plants with higher densities of glandular trichomes can be an efficient criterion to obtain tomato genotypes with higher resistance (repellence to spider mites.O objetivo deste trabalho foi avaliar a eficiência da seleção para maior densidade de tricomas glandulares na resistência (repelência ao ácaro Tetranychus urticae, em populações de tomate derivadas do cruzamento interespecífico Lycopersicon esculentum x L. hirsutum var. glabratum PI 134417. Foram avaliados 19 genótipos quanto à densidade de tricomas, que incluíram 12 derivados de populações avançadas de retrocruzamentos, obtidos a partir do cruzamento original L. esculentum x L. hirsutum var. glabratum PI 134417. Nas faces abaxial e adaxial dos folíolos, realizaram-se as contagens e os tricomas foram classificados em glandulares tipo IV e VI, outros glandulares (tipo I e VII e não glandulares. A repelência aos ácaros foi medida pela distância média, percorrida pelo

  18. Second-harmonic generation as a DNA malignancy indicator of prostate glandular epithelial cells

    International Nuclear Information System (INIS)

    Zheng-Fei, Zhuang; Han-Ping, Liu; Zhou-Yi, Guo; Xiao-Yuan, Deng; Shuang-Mu, Zhuo; Bi-Ying, Yu

    2010-01-01

    This paper first demonstrates second-harmonic generation (SHG) in the intact cell nucleus, which acts as an optical indicator of DNA malignancy in prostate glandular epithelial cells. Within a scanning region of 2.7 μm×2.7 μm in cell nuclei, SHG signals produced from benign prostatic hyperplasia (BPH) and prostate carcinoma (PC) tissues (mouse model C57BL/6) have been investigated. Statistical analyses (t test) of a total of 405 measurements (204 nuclei from BPH and 201 nuclei from PC) show that SHG signals from BPH and PC have a distinct difference (p < 0.05), suggesting a potential optical method of revealing very early malignancy in prostate glandular epithelial cells based upon induced biochemical and/or biophysical modifications in DNA. (geophysics, astronomy and astrophysics)

  19. Selection of oncoplastic surgical technique in Asian breast cancer patients

    Directory of Open Access Journals (Sweden)

    Eui Sun Shin

    2018-01-01

    Full Text Available Background Oncoplastic surgery is being increasingly performed in Korean women; however, unlike Westerners, Korean women usually have small to moderate-sized breasts. To achieve better outcomes in reconstructed breasts, several factors should be considered to determine the optimal surgical method. Methods A total of 108 patients who underwent oncoplastic surgery from January 2013 to December 2016 were retrospectively investigated. We used various methods, including glandular tissue reshaping, latissimus dorsi (LD flap transposition, and reduction oncoplasty, to restore the breast volume and symmetry. Results The mean weight of the tumor specimens was 40.46 g, and the ratio of the tumor specimen weight to breast volume was 0.12 g/mL in the patients who underwent glandular tissue reshaping (n=59. The corresponding values were 101.47 g and 0.14 g/mL, respectively, in the patients who underwent reduction oncoplasty (n=17, and 82.54 g and 0.20 g/mL, respectively, in those treated with an LD flap (n=32. Glandular tissue reshaping was mostly performed in the upper outer quadrant, and LD flap transposition was mostly performed in the lower inner quadrant. No major complications were noted. Most patients were satisfied with the aesthetic results. Conclusions We report satisfactory outcomes of oncoplastic surgical procedures in Korean patients. The results regarding specimen weight and the tumor-to-breast ratio of Asian patients will be a helpful reference point for determining the most appropriate oncoplastic surgical technique.

  20. Ultrastructure of the apical glandular region of the scolex of Proteocephalus torulosus (Cestoda: Proteocephalidae)

    Czech Academy of Sciences Publication Activity Database

    Žďárská, Zdeňka; Scholz, Tomáš; Nebesářová, Jana

    2004-01-01

    Roč. 51, č. 4 (2004), s. 333-338 ISSN 0015-5683 R&D Projects: GA ČR GA524/04/0342; GA AV ČR KSK6005114 Institutional research plan: CEZ:AV0Z6022909 Keywords : Cestoda * Proteocephalus torulosus * apical glandular region Subject RIV: GJ - Animal Vermins ; Diseases, Veterinary Medicine Impact factor: 0.837, year: 2004

  1. Severe glandular tularemia in a patient treated with anti-tumour necrosis factor for psoriatic arthritis.

    Science.gov (United States)

    Calin, Ruxandra; Caumes, Eric; Reibel, Florence; Ali Mohamed, Anzime; Brossier, Florence; Foltz, Violaine; Boussouar, Samia; Fautrel, Bruno; Maurin, Max; Katlama, Christine; Pourcher, Valérie

    2017-07-01

    A case of severe glandular tularemia in a patient receiving anti-tumour necrosis factor (TNF) therapy is reported here. The patient required prolonged treatment with doxycycline-ciprofloxacin due to early relapse after ciprofloxacin was stopped. Tularemia may have a more severe course in patients receiving anti-TNF. This may thus be an indication for more aggressive treatment. Copyright © 2017 The Authors. Published by Elsevier Ltd.. All rights reserved.

  2. Long acting β2-agonist and corticosteroid restore airway glandular cell function altered by bacterial supernatant

    Directory of Open Access Journals (Sweden)

    Nawrocki-Raby Béatrice

    2010-01-01

    Full Text Available Abstract Background Staphylococcus aureus releases virulence factors (VF that may impair the innate protective functions of airway cells. The aim of this study was to determine whether a long-acting β2 adrenergic receptor agonist (salmeterol hydroxynaphthoate, Sal combined with a corticosteroid (fluticasone propionate, FP was able to regulate ion content and cytokine expression by airway glandular cells after exposure to S. aureus supernatant. Methods A human airway glandular cell line was incubated with S. aureus supernatant for 1 h and then treated with the combination Sal/FP for 4 h. The expression of actin and CFTR proteins was analyzed by immunofluorescence. Videomicroscopy was used to evaluate chloride secretion and X-ray microanalysis to measure the intracellular ion and water content. The pro-inflammatory cytokine expression was assessed by RT-PCR and ELISA. Results When the cells were incubated with S. aureus supernatant and then with Sal/FP, the cellular localisation of CFTR was apical compared to the cytoplasmic localisation in cells incubated with S. aureus supernatant alone. The incubation of airway epithelial cells with S. aureus supernatant reduced by 66% the chloride efflux that was fully restored by Sal/FP treatment. We also observed that Sal/FP treatment induced the restoration of ion (Cl and S and water content within the intracellular secretory granules of airway glandular cells and reduced the bacterial supernatant-dependent increase of pro-inflammatory cytokines IL8 and TNFα. Conclusions Our results demonstrate that treatment with the combination of a corticosteroid and a long-acting β2 adrenergic receptor agonist after bacterial infection restores the airway glandular cell function. Abnormal mucus induced by defective ion transport during pulmonary infection could benefit from treatment with a combination of β2 adrenergic receptor agonist and glucocorticoid.

  3. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    International Nuclear Information System (INIS)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih

    2011-01-01

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average ± standard deviation CBT and breast glandularity in this study were 4.2 ± 1.0 cm and 54% ± 23%, respectively. The average equivalent PMMA thickness was 4.0 ± 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  4. Determination of equivalent breast phantoms for different age groups of Taiwanese women: An experimental approach

    Energy Technology Data Exchange (ETDEWEB)

    Dong, Shang-Lung; Chu, Tieh-Chi; Lin, Yung-Chien; Lan, Gong-Yau; Yeh, Yu-Hsiu; Chen, Sharon; Chuang, Keh-Shih [Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China); Department of Radiology, Cheng Hsin General Hospital, 45 Cheng Hsin Street, Pai-Tou District, Taipei 11220, Taiwan (China); Department of Medical Imaging and Radiological Sciences, Kaohsiung Medical University, 100 Shih-Chuan 1st Road, Kaohsiung 80708, Taiwan (China); Department of Biomedical Engineering and Environmental Sciences, National Tsing Hua University, 101 Section 2, Kuang-Fu Road, Hsinchu 30013, Taiwan (China)

    2011-07-15

    Purpose: Polymethylmethacrylate (PMMA) slab is one of the mostly used phantoms for studying breast dosimetry in mammography. The purpose of this study was to evaluate the equivalence between exposure factors acquired from PMMA slabs and patient cases of different age groups of Taiwanese women in mammography. Methods: This study included 3910 craniocaudal screen/film mammograms on Taiwanese women acquired on one mammographic unit. The tube loading, compressed breast thickness (CBT), compression force, tube voltage, and target/filter combination for each mammogram were collected for all patients. The glandularity and the equivalent thickness of PMMA were determined for each breast using the exposure factors of the breast in combination with experimental measurements from breast-tissue-equivalent attenuation slabs. Equivalent thicknesses of PMMA to the breasts of Taiwanese women were then estimated. Results: The average {+-} standard deviation CBT and breast glandularity in this study were 4.2 {+-} 1.0 cm and 54% {+-} 23%, respectively. The average equivalent PMMA thickness was 4.0 {+-} 0.7 cm. PMMA slabs producing equivalent exposure factors as in the breasts of Taiwanese women were determined for the age groups 30-49 yr and 50-69 yr. For the 4-cm PMMA slab, the CBT and glandularity values of the equivalent breast were 4.1 cm and 65%, respectively, for the age group 30-49 yr and 4.4 cm and 44%, respectively, for the age group 50-69 yr. Conclusions: The average thickness of PMMA slabs producing the same exposure factors as observed in a large group of Taiwanese women is less than that reported for American women. The results from this study can provide useful information for determining a suitable thickness of PMMA for mammographic dose survey in Taiwan. The equivalence of PMMA slabs and the breasts of Taiwanese women is provided to allow average glandular dose assessment in clinical practice.

  5. Atypical squamous and glandular cells of undetermined significance (ASCUS and AGUS) of the uterine cervix.

    Science.gov (United States)

    Cenci, M; Vecchione, A

    2000-01-01

    ASCUS (Atypical Squamous Cells of Undetermined Significance) and AGUS (Atypical Glandular Cells of Undetermined Significance), or AGCUS, are two acronyms introduced in 1988 by The Bethesda System (TBS) for reporting borderline cytological changes in cervical cytology. ASCUS and AGUS categories should be subclassified. Five ASCUS subgroups were proposed: 1) ASCUS due to processing defects, 2) with "mature" cytoplasm, 3) in post-menopausal women (a--in the setting of atrophy and b--with estrogen stimulation), 4) atypical metaplasia, and 5) ASCUS with keratinized cytoplasm. AGUS subgroups may be subcategorized in endometrial or endocervical on the basis of origin. Endocervical AGUS should be further qualified, but the analysis of atypical glandular cells may be really difficult and the conclusive diagnosis is frequently "AGUS not otherwise specified". The subclassification of ASCUS and AGUS is useful for an appropriate clinical management, but pertinent patient information (such as age, date of last menstrual period, mechanical therapies, tamoxifen therapy, and others) is needed to avoid an overdiagnosis and consequently an overtreatment. In fact various subgroups require different clinical management. Therefore, an effective communication between cytopathologists and referring physicians is essential in the analysis of squamous and glandular atypias.

  6. Genetic Architecture of Capitate Glandular Trichome Density in Florets of Domesticated Sunflower (Helianthus annuus L.).

    Science.gov (United States)

    Gao, Qing-Ming; Kane, Nolan C; Hulke, Brent S; Reinert, Stephan; Pogoda, Cloe S; Tittes, Silas; Prasifka, Jarrad R

    2017-01-01

    Capitate glandular trichomes (CGT), one type of glandular trichomes, are most common in Asteraceae species. CGT can produce various secondary metabolites such as sesquiterpene lactones (STLs) and provide durable resistance to insect pests. In sunflower, CGT-based host resistance is effective to combat the specialist pest, sunflower moth. However, the genetic basis of CGT density is not well understood in sunflower. In this study, we identified two major QTL controlling CGT density in sunflower florets by using a F 4 mapping population derived from the cross HA 300 × RHA 464 with a genetic linkage map constructed from genotyping-by-sequencing data and composed of 2121 SNP markers. One major QTL is located on chromosome 5, which explained 11.61% of the observed phenotypic variation, and the second QTL is located on chromosome 6, which explained 14.06% of the observed phenotypic variation. The QTL effects and the association between CGT density and QTL support interval were confirmed in a validation population which included 39 sunflower inbred lines with diverse genetic backgrounds. We also identified two strong candidate genes in the QTL support intervals, and the functions of their orthologs in other plant species suggested their potential roles in regulating capitate glandular trichome density in sunflower. Our results provide valuable information to sunflower breeding community for developing host resistance to sunflower insect pests.

  7. Antibacterial, modulatory activity of antibiotics and toxicity from Rhinella jimi (Stevaux, 2002) (Anura: Bufonidae) glandular secretions.

    Science.gov (United States)

    Sales, Débora Lima; Morais-Braga, Maria Flaviana Bezerra; Santos, Antonia Thassya Lucas Dos; Machado, Antonio Judson Targino; Araujo Filho, João Antonio de; Dias, Diógenes de Queiroz; Cunha, Francisco Assis Bezerra da; Saraiva, Rogério de Aquino; Menezes, Irwin Rose Alencar de; Coutinho, Henrique Douglas Melo; Costa, José Galberto Martins; Ferreira, Felipe Silva; Alves, Rômulo Romeu da Nóbrega; Almeida, Waltécio de Oliveira

    2017-08-01

    The increase in microorganisms with resistance to medications has caused a strong preoccupation within the medical and scientific community. Animal toxins studies, such as parotoid glandular secretions from amphibians, possesses a great potential in the development of drugs, such as antimicrobials, as these possess bioactive compounds. It was evaluated Rhinella jimi (Stevaux, 2002) glandular secretions against standard and multi-resistant bacterial strains; the effect of secretions combined with drugs; and determined the toxicity using two biologic in vivo models, and a in vitro model with mice livers. Standard strains were used for the determination of the Minimum Inhibitory Concentration (MIC), while for the modulatory activity of antibiotics, the clinical isolates Escherichia coli 06, Pseudomonas aeruginosa 03 and Staphylococcus aureus 10 were used. Modulatory activity was evaluated by the broth microdilution method with aminoglycosides and β-lactams as target antibiotics. The secretions in association with the antibiotics have a significant reduction in MIC, both the aminoglycosides and β-lactams. The toxicity and cytotoxicity results were lower than the values used in the modulation. R. jimi glandular secretions demonstrated clinically relevant results regarding the modulation of the tested antimicrobials. Copyright © 2017 Elsevier Masson SAS. All rights reserved.

  8. Radioimmunoassay of glandular kallikrein in human plasma after partial purification by immunoaffinity column

    International Nuclear Information System (INIS)

    Nishimura, Kazutaka; Inoue, Yoshikazu; Kokubu, Tatsuo

    1987-01-01

    Glandular kallikrein in human plasma was partially purified by immunoaffinity column and was measured by a radioimmunoassay (RIA). Plasma was diluted with an equal volume of 10 mmol/l sodium phosphate buffer, pH 7.4, containing 0.9% NaCl (PBS) and was applied to an immunoaffinity column from which glandular kallikrein was eluted with 3 mol/l NaSCN (20 ml). The enzymic fraction was concentrated with an Amicon PM 10 filter and dialyzed against PBS. The final recovery of the enzyme was 51.6 ± 1.6%, determined by using [ 125 I]kallikrein. The usable range of the standard curve covered 2.5-100 ng/tube. The coefficient of variation within the series was 5.9%, and the coefficient of variation between the series was 7.6%. In healthy controls, the plasma content of glandular kallikrein was 1.36 ± 0.39 ng/ml. In patients with acute pancreatitis, the plasma concentration was 8.02 ± 6.15 ng/ml, significantly different from the control group. (Auth.)

  9. Development of a patient-specific two-compartment anthropomorphic breast phantom

    International Nuclear Information System (INIS)

    Prionas, Nicolas D; Burkett, George W; McKenney, Sarah E; Chen, Lin; Boone, John M; Stern, Robin L

    2012-01-01

    The purpose of this paper is to develop a technique for the construction of a two-compartment anthropomorphic breast phantom specific to an individual patient's pendant breast anatomy. Three-dimensional breast images were acquired on a prototype dedicated breast computed tomography (bCT) scanner as part of an ongoing IRB-approved clinical trial of bCT. The images from the breast of a patient were segmented into adipose and glandular tissue regions and divided into 1.59 mm thick breast sections to correspond to the thickness of polyethylene stock. A computer-controlled water-jet cutting machine was used to cut the outer breast edge and the internal regions corresponding to glandular tissue from the polyethylene. The stack of polyethylene breast segments was encased in a thermoplastic ‘skin’ and filled with water. Water-filled spaces modeled glandular tissue structures and the surrounding polyethylene modeled the adipose tissue compartment. Utility of the phantom was demonstrated by inserting 200 µm microcalcifications as well as by measuring point dose deposition during bCT scanning. Affine registration of the original patient images with bCT images of the phantom showed similar tissue distribution. Linear profiles through the registered images demonstrated a mean coefficient of determination (r 2 ) between grayscale profiles of 0.881. The exponent of the power law describing the anatomical noise power spectrum was identical in the coronal images of the patient's breast and the phantom. Microcalcifications were visualized in the phantom at bCT scanning. The real-time air kerma rate was measured during bCT scanning and fluctuated with breast anatomy. On average, point dose deposition was 7.1% greater than the mean glandular dose. A technique to generate a two-compartment anthropomorphic breast phantom from bCT images has been demonstrated. The phantom is the first, to our knowledge, to accurately model the uncompressed pendant breast and the glandular tissue

  10. Modelling of the mammographic exposure conditions for radiological detriment study in the Valencian Breast Cancer Screening Programme

    International Nuclear Information System (INIS)

    Ferrer, S.; Ramos, M.; Villaescusa, J. I.; Verdu, G.; Salas, M. D.; Cuevas, M. D.

    2005-01-01

    Breast screening programmes are the best weapon to fight against breast cancer. Nevertheless, despite the benefits, this practice supposes a radiological risk that cannot be forgotten. In order to calculate breast glandular doses, different MCNP-4C2 models have been developed, simulating the exposure conditions. Radiological detriments have been transported from the population under study in the UNSCEAR 2000 to the Valencian Community, obtaining the detection-induced cancer ratio (DICR) for this population. (authors)

  11. Comparative glandular trichome transcriptome-based gene characterization reveals reasons for differential (-)-menthol biosynthesis in Mentha species.

    Science.gov (United States)

    Akhtar, Md Qussen; Qamar, Nida; Yadav, Pallavi; Kulkarni, Pallavi; Kumar, Ajay; Shasany, Ajit Kumar

    2017-06-01

    The genes involved in menthol biosynthesis are reported earlier in Mentha × piperita. But the information on these genes is not available in Mentha arvensis. To bridge the gap in knowledge on differential biosynthesis of monoterpenes leading to compositional variation in the essential oil of these species, a comparative transcriptome analysis of the glandular trichome (GT) was carried out. In addition to the mevalonic acid (MVA) and methylerythritol phosphate (MEP) pathway genes, about 210 and 196 different terpene synthases (TPSs) transcripts were identified from annotation in M. arvensis and M. × piperita, respectively, and correlated to several monoterpenes present in the essential oil. Six isoforms of (-)-menthol dehydrogenases (MD), the last enzyme of the menthol biosynthetic pathway, were identified, cloned and characterized from the transcriptome data (three from each species). Varied expression levels and differential enzyme kinetics of these isoforms indicated the nature and composition of the product, as these isoforms generate both (-)-menthol and (+)-neomenthol from (-)-menthone and converts (-)-menthol to (-)-menthone in the reverse reaction, and hence together determine the quantity of (-)-menthol in the essential oil in these two species. Several genes for high value minor monoterpenes could also be identified from the transcriptome data. © 2017 Scandinavian Plant Physiology Society.

  12. Characterization of fibrillar collagens and extracellular matrix of glandular benign prostatic hyperplasia nodules.

    Directory of Open Access Journals (Sweden)

    Tyler M Bauman

    Full Text Available Recent studies have associated lower urinary tract symptoms (LUTS in men with prostatic fibrosis, but a definitive link between collagen deposition and LUTS has yet to be demonstrated. The objective of this study was to evaluate ECM and collagen content within normal glandular prostate tissue and glandular BPH, and to evaluate the association of clinical parameters of LUTS with collagen content.Fibrillar collagen and ECM content was assessed in normal prostate (48 patients and glandular BPH nodules (24 patients using Masson's trichrome stain and Picrosirius red stain. Second harmonic generation (SHG imaging was used to evaluate collagen content. Additional BPH tissues (n = 47 were stained with Picrosirius red and the association between clinical parameters of BPH/LUTS and collagen content was assessed.ECM was similar in normal prostate and BPH (p = 0.44. Total collagen content between normal prostate and glandular BPH was similar (p = 0.27, but a significant increase in thicker collagen bundles was observed in BPH (p = 0.045. Using SHG imaging, collagen content in BPH (mean intensity = 62.52; SEM = 2.74 was significantly higher than in normal prostate (51.77±3.49; p = 0.02. Total collagen content was not associated with treatment with finasteride (p = 0.47 or α-blockers (p = 0.52, pre-TURP AUA symptom index (p = 0.90, prostate-specific antigen (p = 0.86, post-void residual (PVR; p = 0.32, prostate size (p = 0.21, or post-TURP PVR (p = 0.51. Collagen content was not associated with patient age in patients with BPH, however as men aged normal prostatic tissue had a decreased proportion of thick collagen bundles.The proportion of larger bundles of collagen, but not total collagen, is increased in BPH nodules, suggesting that these large fibers may play a role in BPH/LUTS. Total collagen content is independent of clinical parameters of BPH and LUTS. If fibrosis and overall ECM deposition are

  13. Breast hamartoma: A report of 14 cases of an under-recognized and under-reported entity

    Directory of Open Access Journals (Sweden)

    R.A. Amir

    2016-01-01

    Results: A total of 14 cases with diagnosis of breast hamartoma were identified in our institute. Histologically the lesion is mostly sharply demarcated showing a mixture of varying proportions of fibrous, adipose, and glandular tissue. 13 cases were seen in females (93% and only one rare occurrence in a male patient (7%. The age ranges quite vastly from 18 to 51 years (mean 33 years. Two-third of these lesions were seen involving the right breast (9 cases/64.3% and only one-third in the left side (5 cases/35.7%. 13 out of 14 patients had a well circumscribed lesion (92.9% while only 1 case showed irregular borders (7.1%. The size varied from 1.4 to 9.5 cm. Three cases (21.4% showed evidence of myoid differentiation, a histopathologic variance which is important to identify however has no clinical significance. 3 cases had associated epithelial ductal hyperplasia of the usual type varying from mild (2 cases to moderate (1 case; with two of these cases exhibiting additional features of fibrocystic mastopathy including adenosis, apocrine metaplasia, and cyst formation. None of our cases showed any malignancy or pseudoangiomatous stroma hyperplasia (PASH.

  14. Nipple Sparing Mastectomy: Does Breast Morphological Factor Related to Necrotic Complications?

    Directory of Open Access Journals (Sweden)

    Prakasit Chirappapha, MD

    2014-01-01

    Conclusions: Large glandular specimen increases the risk of NAC necrosis. The degree of ptosis and the distance between the sternal notch and the NAC have no significant impact on necrotic complications in NSM. To reduce the necrotic complications in large breast after NSM, reconstruction should better be performed with autologous flap or slow skin expansion using the expander technique.

  15. Glandular trichomes in Connarus suberosus (Connaraceae: distribution, structural organization and probable functions

    Directory of Open Access Journals (Sweden)

    João Donizete Denardi

    2012-03-01

    Full Text Available Connarus suberosus is a typical species of the Brazilian Cerrado biome, and its inflorescences and young vegetative branches are densely covered by dendritic trichomes. The objective of this study was to report the occurrence of a previously undescribed glandular trichome of this species. The localization, origin and structure of these trichomes were investigated under light, transmission and scanning electron microscopy. Collections were made throughout the year, from five adult specimens of Connarus suberosus near Botucatu, São Paulo, Brazil, including vegetative and reproductive apices, leaves and fruits in different developmental stages, as well as floral buds and flowers at anthesis. Glandular trichomes (GTs occurred on vegetative and reproductive organs during their juvenile stages. The GTs consisted of a uniseriate, multicellular peduncle, whose cells contain phenolic compounds, as well as a multicellular glandular portion that accumulates lipids. The glandular cell has thin wall, dense cytoplasm (with many mitochondria, plastids and dictyosomes, and a large nucleus with a visible nucleolus. The starch present in the plastids was hydrolyzed during the synthesis phase, reducing the density of the plastid stroma. Some plastids were fused to vacuoles, and some evidence suggested the conversion of plastids into vacuoles. During the final activity stages of the GTs, a darkening of the protoplasm was observed in some of the glandular cells, as a programmed cell death; afterwards, became caducous. The GTs in C. suberosus had a temporal restriction, being limited to the juvenile phase of the organs. Their presence on the exposed surfaces of developing organs and the chemical nature of the reserve products, suggest that these structures are food bodies. Field observations and detailed studies of plant-environment interactions, as well as chemical analysis of the reserve compounds, are still necessary to confirm the role of these GTs as feeding

  16. Evaluation of the BreastSimulator software platform for breast tomography

    Science.gov (United States)

    Mettivier, G.; Bliznakova, K.; Sechopoulos, I.; Boone, J. M.; Di Lillo, F.; Sarno, A.; Castriconi, R.; Russo, P.

    2017-08-01

    The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f)  =  α/f   β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.

  17. Foetal antigen 2 (FA2) in the stromal reaction induced by breast carcinoma

    DEFF Research Database (Denmark)

    Rasmussen, H B; Teisner, B; Andersen, J A

    1992-01-01

    An indirect immunoperoxidase technique was used to examine the distribution of foetal antigen 2 (FA2), a recently described basement membrane (BM)-associated antigen, in invasive breast carcinoma (n = 34), fibroadenoma (n = 5) and normal breast tissue (n = 5), and to compare its distribution...... with that of laminin and collagen type IV. In normal breast tissue, FA2 was detected in the intralobular stroma as a broad band around acini and ducts, but was not present in the interlobular stroma. In areas of carcinoma in situ, FA2 was present diffusely around and in close contact with the glandular elements......, the staining being more intense than that found around normal glandular structures. Two distinct patterns of FA2 distribution were found in adenocarcinomas of the breast. In the fibroblast reaction type, fibroblast staining dominated, whilst in the stromal reaction type, intense and extensive staining...

  18. Capitate glandular trichomes in Aldama discolor (Heliantheae - Asteraceae): morphology, metabolite profile and sesquiterpene biosynthesis.

    Science.gov (United States)

    Bombo, A B; Appezzato-da-Glória, B; Aschenbrenner, A-K; Spring, O

    2016-05-01

    The capitate glandular trichome is the most common type described in Asteraceae species. It is known for its ability to produce various plant metabolites of ecological and economic importance, among which sesquiterpene lactones are predominant. In this paper, we applied microscopy, phytochemical and molecular genetics techniques to characterise the capitate glandular trichome in Aldama discolor, a native Brazilian species of Asteraceae, with pharmacological potential. It was found that formation of trichomes on leaf primordia of germinating seeds starts between 24 h and 48 h after radicle growth indicates germination. The start of metabolic activity of trichomes was indicated by separation of the cuticle from the cell wall of secretory cells at the trichome tip after 72 h. This coincided with the accumulation of budlein A, the major sesquiterpene lactone of A. discolor capitate glandular trichomes, in extracts of leaf primordia after 96 h. In the same timeframe of 72-96 h post-germination, gene expression studies showed up-regulation of the putative germacrene A synthase (pGAS2) and putative germacrene A oxidase (pGAO) of A. discolor in the transcriptome of these samples, indicating the start of sesquiterpene lactone biosynthesis. Sequencing of the two genes revealed high similarity to HaGAS and HaGAO from sunflower, which shows that key steps of this pathway are highly conserved. The processes of trichome differentiation, metabolic activity and genetic regulation in A. discolor and in sunflower appear to be typical for other species of the subtribe Helianthinae. © 2015 German Botanical Society and The Royal Botanical Society of the Netherlands.

  19. Estimation of the average glandular dose on a team of tomosynthesis

    International Nuclear Information System (INIS)

    Nunez Martinez, L. M. R.; Sanchez Jimenez, J.; Pizarro trigo, F.

    2013-01-01

    Seeking to improve the information that gives us an image of mammography the manufacturers have implemented tomosynthesis. With this method of acquisition and reconstruction of image we went from having a 2D to a 3D image image, in such a way that it reduces or eliminates the effect of overlap of tissues. The estimate of the dose, which is always a fundamental parameter in the control of quality of radiology equipment, is more in the case of mammography by the radiosensitivity of this body and the frequency of their use. The objective of this work is the determination of the mean in a team glandular dose of with tomosynthesis mammography. (Author)

  20. Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer

    International Nuclear Information System (INIS)

    Jo, Sun Mi; Chun, Mi Sun; Kim, Mi Hwa; Oh, Young Taek; Noh, O Kyu; Kang, Seung Hee

    2010-01-01

    Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inflamammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. The use of 3D CT based planning reduced the

  1. Difference in the Set-up Margin between 2D Conventional and 3D CT Based Planning in Patients with Early Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Jo, Sun Mi; Chun, Mi Sun; Kim, Mi Hwa; Oh, Young Taek; Noh, O Kyu [Ajou University School of Medicine, Seoul (Korea, Republic of); Kang, Seung Hee [Inje University, Ilsan Paik Hospital, Ilsan (Korea, Republic of)

    2010-11-15

    Simulation using computed tomography (CT) is now widely available for radiation treatment planning for breast cancer. It is an important tool to help define the tumor target and normal tissue based on anatomical features of an individual patient. In Korea, most patients have small sized breasts and the purpose of this study was to review the margin of treatment field between conventional two-dimensional (2D) planning and CT based three-dimensional (3D) planning in patients with small breasts. Twenty-five consecutive patients with early breast cancer undergoing breast conservation therapy were selected. All patients underwent 3D CT based planning with a conventional breast tangential field design. In 2D planning, the treatment field margins were determined by palpation of the breast parenchyma (In general, the superior: base of the clavicle, medial: midline, lateral: mid - axillary line, and inferior margin: 2 m below the inflamammary fold). In 3D planning, the clinical target volume (CTV) ought to comprise all glandular breast tissue, and the PTV was obtained by adding a 3D margin of 1 cm around the CTV except in the skin direction. The difference in the treatment field margin and equivalent field size between 2D and 3D planning were evaluated. The association between radiation field margins and factors such as body mass index, menopause status, and bra size was determined. Lung volume and heart volume were examined on the basis of the prescribed breast radiation dose and 3D dose distribution. The margins of the treatment field were smaller in the 3D planning except for two patients. The superior margin was especially variable (average, 2.5 cm; range, -2.5 to 4.5 cm; SD, 1.85). The margin of these targets did not vary equally across BMI class, menopause status, or bra size. The average irradiated lung volume was significantly lower for 3D planning. The average irradiated heart volume did not decrease significantly. The use of 3D CT based planning reduced the

  2. Presentation of Apocrine Breast Carcinoma in a Woman with Bilateral Silicone Prosthesis; Presentacion de un carcinoma apocrino de mama en una mujer con protesis bilateral de silicona

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, J. A.; Salvador, R.; Salvador, M.; Barranco, C.

    2003-07-01

    We present a case of apocrine breast carcinoma in a 45 year-old woman with bilateral silicone breast prosthesis whose clinical manifestations and mammography were that of a palpable nodule-high glandular density, rounded and with imprecise borders devoid of any visible microcalcifications. A bibliographical revision confirmed the infrequent association of this type of tumor with the presence of silicone breast implants, precisely in which we consider its radiological interest to lie. (Author) 11 refs.

  3. Variáveis reprodutivas e risco para doenças benignas de mama: estudo caso-controle Reproductive variables and risk of benign breast diseases: a case-control study

    Directory of Open Access Journals (Sweden)

    Ellen E. Hardy

    1990-10-01

    Full Text Available Foram estudadas 257 mulheres com diagnóstico de doença benigna de mama (DBM, atestado por anatomopatológico ou citologia, e um controle para cada uma delas. Foram apresentados resultados das possíveis relações entre variáveis reprodutivas e o risco para DBM. Os casos e controles foram comparados levando em conta a idade na menarca e na menopausa, o número de gravidezes, de meses em que amamentaram e de ciclos menstruais ovulatórios, e os antecedentes familiares de câncer de mama. Mostraram influência significativa, em relação às DBM, a nuliparidade, aumentando o risco enquanto a idade de 30 ou mais anos no primeiro parto o reduziu; o número de ciclos ovulatórios, que foi significativamente maior para os casos, e a média de meses de uso de pílula, menor entre as mulheres com DBM. O uso de contraceptivos orais apresentou um efeito protetor apenas quando a duração total do uso foi maior que dois anos. Os resultados não se revelaram novos ou diferentes se comparados com outros estudos, mas confirmam a relativa concordância entre os fatores de risco para DBM e para câncer de mama, ainda que as relações entre esses fatores e as DBM não sejam tão claras como o são para o câncer, e existam também algumas discrepâncias.The purpose of the study was the identification of risk factors for benign breast diseases (BBD; 257 women with BBD diagnosed through pathological anatomy or citology and a matched control for each were studied. Subjects were selected at The State University of Campinas Hospital and at a private clinic. To enter the study cases had to have a first diagnosis of BBD between October 1979 and August 1984. The following BBD were considered: dysplasia, fibroadenoma, cystic disease, papilloma and ductal ectasia. Reproductive variables were studied as risk factors, including menstrual ovulatory cycles. The date on which the BBD was diagnosed was defined as the index date. For controls, data were considered up to when

  4. Glandular differentiation in dedifferentiated chondrosarcoma: molecular evidence of a rare phenomenon.

    Science.gov (United States)

    Jour, George; Liu, Yajuan; Ricciotti, Robert; Pritchard, Colin; Hoch, Benjamin L

    2015-09-01

    Epithelial glandular differentiation in dedifferentiated chondrosarcoma has not been described. Our patient was a 64-year-old man with a history of prostate cancer status post-radiation and hormonal therapy. On screening bone scan, he was found to have increased uptake in his right femoral shaft. Biopsy revealed intermediate-grade conventional chondrosarcoma. Subsequent femoral resection was remarkable for an intermediate-grade chondrosarcomatous component juxtaposed to an area composed of anastomosing nests and cords of malignant epithelial cells showing nuclear atypia and increased mitotic activity. A fibroblastic-appearing spindle cell population was intimately associated with the epithelial cells. The epithelial cells labeled with 34bE12, AE1/AE3, EMA, and Vimentin (both spindled and epithelial components) while being negative for prostate-specific antigen, prostate specific acid phosphatase, cytokeratin 20, thyroid transcription factor-1, and CDX2. The patient developed local recurrence 9 months after the initial resection but has had no metastatic disease and consistently undetectable prostate-specific antigen levels. Deep parallel sequencing of the dedifferentiated component showed a nonsynonymous mutation at exon 4 of IDH1 gene at codon R132 leading to a substitution of arginine, with serine confirming glandular differentiation in dedifferentiated chondrosarcoma. Copyright © 2015 Elsevier Inc. All rights reserved.

  5. Development and Structure of Internal Glands and External Glandular Trichomes in Pogostemon cablin

    Science.gov (United States)

    Guo, Jiansheng; Yuan, Yongming; Liu, Zhixue; Zhu, Jian

    2013-01-01

    Pogostemon cablin possesses two morphologically and ontogenetically different types of glandular trichomes, one type of bristle hair on the surfaces of leaves and stems and one type of internal gland inside the leaves and stems. The internal gland originates from elementary meristem and is associated with the biosynthesis of oils present inside the leaves and stems. However, there is little information on mechanism for the oil biosynthesis and secretion inside the leaves and stems. In this study, we identified three kinds of glandular trichome types and two kinds of internal gland in the Pogostemon cablin. The oil secretions from internal glands of stems and leaves contained lipids, flavones and terpenes. Our results indicated that endoplasmic reticulum and plastids and vacuoles are likely involved in the biosynthesis of oils in the internal glands and the synthesized oils are transported from endoplasmic reticulum to the cell wall via connecting endoplasmic reticulum membranes to the plasma membrane. And the comparative analysis of the development, distribution, histochemistry and ultrastructures of the internal and external glands in Pogostemon cablin leads us to propose that the internal gland may be a novel secretory structure which is different from external glands. PMID:24205002

  6. Cloning of a sesquiterpene synthase from Lavandula x intermedia glandular trichomes.

    Science.gov (United States)

    Sarker, Lukman S; Demissie, Zerihun A; Mahmoud, Soheil S

    2013-11-01

    The essential oil (EO) of Lavandula is dominated by monoterpenes, but can also contain small amounts of sesquiterpenes, depending on species and environmental conditions. For example, the sesquiterpene 9-epi-caryophyllene can make up to 8 % of the EO in a few species, including those commercially propagated for EO production. Here, we report the cloning and functional characterization of 9-epi-caryophyllene synthase (LiCPS) from the glandular trichomes of Lavandula x intermedia, cv. Grosso. The 1,617 bp open reading frame of LiCPS, which did not encode a transit peptide, was expressed in Escherichia coli and the recombinant protein purified by Ni-NTA agarose affinity chromatography. The ca. 60 kDa recombinant protein specifically converted farnesyl diphosphate to 9-epi-caryophyllene. LiCPS also produced a few monoterpenes when assayed with the monoterpene precursor geranyl diphosphate (GPP), but--unlike most monoterpene synthases--was not able to derive detectable amounts of any products from the cis isomer of GPP, neryl diphosphate. The LiCPS transcripts accumulated in developing L. x intermedia flowers and were highly enriched in glandular trichomes, but were not detected in leaves suggesting that the transcriptional expression of this gene is spatially and developmentally regulated.

  7. Molecular cloning and functional characterization of borneol dehydrogenase from the glandular trichomes of Lavandula x intermedia.

    Science.gov (United States)

    Sarker, Lukman S; Galata, Mariana; Demissie, Zerihun A; Mahmoud, Soheil S

    2012-12-15

    Several varieties of Lavandula x intermedia (lavandins) are cultivated for their essential oils (EOs) for use in cosmetic, hygiene and personal care products. These EOs are mainly constituted of monoterpenes including camphor, which contributes an off odor reducing the olfactory appeal of the oil. We have recently constructed a cDNA library from the glandular trichomes (the sites of EO synthesis) of L. x intermedia plants. Here, we describe the cloning of a borneol dehydrogenase cDNA (LiBDH) from this library. The 780 bp open reading frame of the cDNA encoded a 259 amino acid short chain alcohol dehydrogenase with a predicted molecular mass of ca. 27.5 kDa. The recombinant LiBDH was expressed in Escherichia coli, purified by Ni-NTA agarose affinity chromatography, and functionally characterized in vitro. The bacterially produced enzyme specifically converted borneol to camphor as the only product with K(m) and k(cat) values of 53 μM and 4.0 × 10(-4) s(-1), respectively. The LiBDH transcripts were specifically expressed in glandular trichomes of mature flowers indicating that like other Lavandula monoterpene synthases the expression of this gene is regulated in a tissue-specific manner. The cloning of LiBDH has far reaching implications in improving the quality of Lavandula EOs through metabolic engineering. Copyright © 2012 Elsevier Inc. All rights reserved.

  8. Radiotherapy of breast fibrosis

    International Nuclear Information System (INIS)

    Heibel, J.H.

    1979-01-01

    In a retrospective study radiotherapy of breast fibrosis in hormone-treated men with histologically confirmed prostate carcinoma was examined. 10 patients had received hormones even before irradiation, 113 obtained hormone administration only after irradiation. The objective size of the glandular body and the overall size of the breast were measured with a special method developed by the author. 46 patients indicated complaints. With hypertrophic mamma and hypertrophic mamilla in 67 examined patients, 127 different symptoms resulted in total. Four patients of the group who had obtained hormones before irradiation, suffered from subjective symptoms. It resulted that radiotherapy of breast fibrosis carried out during hormone treatment is no gynecomastia prophylaxis, that already existent mamma hypertrophies are irreversible, but that existent sensations were notably reduced within 6 months after irradiation therapy. These results indicate the necessity of a radiotherapy of the mamma fibrosis before the hormone treatment is begun. Particularly in cases of higher operative risks, also the possibility of preferring radiotherapy to mastectomy should be fully utilized, in view of adequate or even better therapeutic results. (orig./MG) [de

  9. Impact of contra-lateral breast reshaping on mammographic surveillance in women undergoing breast reconstruction following mastectomy for breast cancer.

    Science.gov (United States)

    Nava, Maurizio B; Rocco, Nicola; Catanuto, Giuseppe; Falco, Giuseppe; Capalbo, Emanuela; Marano, Luigi; Bordoni, Daniele; Spano, Andrea; Scaperrotta, Gianfranco

    2015-08-01

    The ultimate goal of breast reconstruction is to achieve symmetry with the contra-lateral breast. Contra-lateral procedures with wide parenchymal rearrangements are suspected to impair mammographic surveillance. This study aims to evaluate the impact on mammographic detection of mastopexies and breast reductions for contralateral adjustment in breast reconstruction. We retrospectively evaluated 105 women affected by uni-lateral breast cancer who underwent mastectomy and immediate two-stage reconstruction between 2002 and 2007. We considered three groups according to the contra-lateral reshaping technique: mastopexy or breast reduction with inferior dermoglandular flap (group 1); mastopexy or breast reduction without inferior dermoglandular flap (group 2); no contra-lateral reshaping (group 3). We assessed qualitative mammographic variations and breast density in the three groups. Statistically significant differences have been found when comparing reshaped groups with non reshaped groups regarding parenchymal distortions, skin thickening and stromal edema, but these differences did not affect cancer surveillance. The surveillance mammography diagnostic accuracy in contra-lateral cancer detection was not significantly different between the three groups (p = 0.56), such as the need for MRI for equivocal findings at mammographic contra-lateral breast (p = 0.77) and the need for core-biopsies to confirm mammographic suspect of contra-lateral breast cancer (p = 0.90). This study confirms previous reports regarding the safety of mastopexies and breast reductions when performed in the setting of contra-lateral breast reshaping after breast reconstruction. Mammographic accuracy, sensitivity and specificity are not affected by the glandular re-arrangement. These results provide a further validation of the safety of current reconstructive paradigms. Copyright © 2015 Elsevier Ltd. All rights reserved.

  10. Optimization of a dual-energy contrast-enhanced technique for a photon-counting digital breast tomosynthesis system: I. A theoretical model

    International Nuclear Information System (INIS)

    Carton, Ann-Katherine; Ullberg, Christer; Lindman, Karin; Acciavatti, Raymond; Francke, Tom; Maidment, Andrew D. A.

    2010-01-01

    % with 50% glandular breast tissue, w t values were found to range from 0.46 to 0.72 for all breast thicknesses and Sn-Cu filter pairs studied. The optimal w t values needed to cancel all possible breast tissue glandularites vary by less than 1% for 20 mm thick breasts and 18% for 80 mm breasts. The system configuration where one collimator slit covered by Sn is alternated with two collimator slits covered by Cu delivers SDNR/√(MGD) nearest to the peak value. A reasonable compromise is a 0.16 mm Sn-0.23 mm Cu filter pair, resulting in SDNR values between 1.64 and 0.61 and MGD between 0.70 and 0.53 mGy for 20-80 mm thick breasts at the maximum tube current. Conclusions: A DE acquisition technique for a photon-counting DBT imaging system has been developed and optimized.

  11. A Survey On Mean Glandular Dose From Full-Field Digital Mammography Systems, Operate Using Mo/ Mo And W/Rh Target/ Filter Combinations

    International Nuclear Information System (INIS)

    Noriah Jamal; Siti Selina Abdul Hamid; Humairah Samad Cheung; Siti Kamariah Che Mohamed; Ellyda Muhammed Nordin; Radhiana Hassan; Rehir Dahalan

    2013-01-01

    We had conducted a survey on Mean Glandular Dose (MGD) from Full-Field Digital Mammography systems (FFDM) operate using Molybdenum/ Molybdenum (Mo/ Mo) and Tungsten/ Rhodium (W/ Rh) target/ filter combinations. A survey was carried out at two randomly selected mammography centres in Malaysia, namely National Cancer Society and International Islamic University of Malaysia. The first centre operates using a W/ Rh, while the second centre operates using an Mo/ Mo target/ filter combinations. On the basis of recorded information, data on mammographic views, MGD, age and Compressed Breast Thickness (CBT) were recorded for 100 patients, for each mammographic centre respectively. The MGD data were analyzed for variation with age group, with 5 years increment. The MGD data were also analyzed for variation with CBT, with 5 mm increment. We found that for both CC and MLO views, FFDM systems operated using Mo/ Mo and W/ Rh target/ filter combinations present the same trend on MGD. The average MGD decreases as age increases. While average MGD increases with the increasing of CBT. However, FFDM system operates using Mo/ Mo gives higher MGD as compared with FFDM system operates using W/ Rh. (author)

  12. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme.

    Science.gov (United States)

    Timmermans, Lore; De Hauwere, An; Bacher, Klaus; Bosmans, Hilde; Lemmens, Kim; Bleyen, Luc; Van Limbergen, Erik; Martens, Patrick; Van Steen, Andre; Mortier, Griet; Van Herck, Koen; Thierens, Hubert

    2014-08-01

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30% in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. • Performance parameters showed no major differences after digitalisation to CR or DR. • Transition from SFM to CR results in a higher mean glandular dose. • Transition from SFM to DR results in a lower mean glandular dose.

  13. Coronary calcium scoring with MDCT: The radiation dose to the breast and the effectiveness of bismuth breast shield

    International Nuclear Information System (INIS)

    Yilmaz, Mehmet Halit; Yasar, Dogan; Albayram, Sait; Adaletli, Ibrahim; Ozer, Harun; Ozbayrak, Mustafa; Mihmanli, Ismail; Akman, Canan

    2007-01-01

    Objective: The purpose of our study was to determine the breast radiation dose during coronary calcium scoring with multidetector computerized tomography (MDCT). We also evaluated the degree of dose reduction by using a bismuth breast shield when performing coronary calcium scoring with MDCT. Materials and methods: The dose reduction achievable by shielding the adult (35 years or older) female breasts was studied in 25 women who underwent coronary calcium scoring with MDCT. All examinations were performed with a 16-MDCT scanner. To compare the shielded versus unshielded breast dose, the examinations were performed with (right breast) and without (left breast) breast shielding in all patients. With this technique the superficial breast doses were calculated. To determine the average glandular breast radiation dose, we imaged an anthropomorphic dosimetric phantom into which calibrated dosimeters were placed to measure the dose to the breast. The phantom was imaged using the same protocol. Radiation doses to the breasts with and without the breast shielding were measured and compared using the Student's t-test. Results: The mean radiation doses with and without the breast shield were 5.71 ± 1.1 mGy versus 9.08 ± 1.5 mGy, respectively. The breast shield provided a 37.12% decrease in radiation dose to the breast with shielding. The difference between the dose received by the breasts with and without bismuth shielding was significant, with a p-value of less than 0.001. Conclusion: The high radiation during MDCT greatly exceeds the recommended doses and should not be underestimated. Bismuth in plane shielding for coronary calcium scoring with MDCT decreased the radiation dose to the breast. We recommend routine use of breast shields in female patients undergoing calcium scoring with MDCT

  14. Nerve Invasion by Epithelial Cells in Benign Breast Diseases

    Directory of Open Access Journals (Sweden)

    Yu-Jan Chan

    2009-03-01

    Full Text Available Nerve invasion by glandular epithelial cells in a lesion is usually regarded as invasive carcinoma. However, some benign conditions in the pancreas, prostate, breast and other organs may show involvement of nerve bundles by benign epithelial cells. We report an 18-year-old female with nerve invasion in benign breast disease. The lesion in her right breast revealed fibrocystic changes with ductal hyperplasia and stromal sclerosis. Perineural and intraneural involvement by bland-looking small ducts lined by 2 layers of cells including an outer layer of myoepithelial cells were found, suggestive of benign nerve invasion. There was no evidence of malignant cells in any of the sections. The patient remains well after 31 months of follow-up. About 44 cases of nerve invasion in benign breast diseases have been reported in the literature. It is necessary to carefully evaluate nerve involvement in breast lesions to avoid over-diagnosis and inappropriate operation.

  15. Generation of a suite of 3D computer-generated breast phantoms from a limited set of human subject data

    International Nuclear Information System (INIS)

    Hsu, Christina M. L.; Palmeri, Mark L.; Segars, W. Paul; Veress, Alexander I.; Dobbins, James T. III

    2013-01-01

    Purpose: The authors previously reported on a three-dimensional computer-generated breast phantom, based on empirical human image data, including a realistic finite-element based compression model that was capable of simulating multimodality imaging data. The computerized breast phantoms are a hybrid of two phantom generation techniques, combining empirical breast CT (bCT) data with flexible computer graphics techniques. However, to date, these phantoms have been based on single human subjects. In this paper, the authors report on a new method to generate multiple phantoms, simulating additional subjects from the limited set of original dedicated breast CT data. The authors developed an image morphing technique to construct new phantoms by gradually transitioning between two human subject datasets, with the potential to generate hundreds of additional pseudoindependent phantoms from the limited bCT cases. The authors conducted a preliminary subjective assessment with a limited number of observers (n= 4) to illustrate how realistic the simulated images generated with the pseudoindependent phantoms appeared. Methods: Several mesh-based geometric transformations were developed to generate distorted breast datasets from the original human subject data. Segmented bCT data from two different human subjects were used as the “base” and “target” for morphing. Several combinations of transformations were applied to morph between the “base’ and “target” datasets such as changing the breast shape, rotating the glandular data, and changing the distribution of the glandular tissue. Following the morphing, regions of skin and fat were assigned to the morphed dataset in order to appropriately assign mechanical properties during the compression simulation. The resulting morphed breast was compressed using a finite element algorithm and simulated mammograms were generated using techniques described previously. Sixty-two simulated mammograms, generated from morphing

  16. Exposure parameters of mammograms with and without mass lesions from a South African breast care centre

    International Nuclear Information System (INIS)

    Acho, Sussan N.; Boonzaier, Willem P. E.; Nel, Ina F.

    2017-01-01

    In South African breast care centres, full-field digital mammography units provide breast imaging services to symptomatic and asymptomatic women simultaneously. This study evaluated the technical exposure parameters of 800 mammograms of which 100 mammograms had obvious mass lesions in the fibro-glandular tissue. The average breast compression force of mammograms with mass lesions in the fibro-glandular tissue was 18.4% less than the average breast compression force of mammograms without mass lesions. The average mean glandular dose (MGD), tube potential (kV p ) and compressed breast thickness (CBT) values were 2.14 mGy, 30.5 kV p and 63.9 mm, respectively, for mammograms with mass lesions, and 1.45 mGy, 29.6 kV p and 56.9 mm, respectively, for mammograms without mass lesions. Overall, the average MGD and mean CBT of mammograms with mass lesion were significantly higher compared to those without mass lesions (p < 0.05), although there was no significant difference in their tube potentials (p > 0.05). (authors)

  17. Increased adrenocortical response to adrenocorticotropic hormone (ACTH) in sport horses with equine glandular gastric disease (EGGD).

    Science.gov (United States)

    Scheidegger, M D; Gerber, V; Bruckmaier, R M; van der Kolk, J H; Burger, D; Ramseyer, A

    2017-10-01

    This study tested the hypothesis that adrenocortical function would be altered in horses with equine gastric ulcer syndrome (EGUS). Twenty-six sport horses competing at national or international levels in eventing (n=15) or endurance (n=11) were subjected to a gastroscopic examination and an adrenocorticotropic hormone (ACTH) stimulation test. Salivary cortisol concentrations were measured before (baseline) and after (30, 60, 90, 120 and 150min) IV ACTH injection (1μg/kg bodyweight). Within EGUS, two distinct diseases, equine squamous gastric disease (ESGD) and equine glandular gastric disease (EGGD), can be distinguished. ESGD was diagnosed in 8/11 (73%; 95% confidence intervals [95%CI], 43-92%) endurance horses and 5/15 (33%; 95% CI, 14-58%) eventing horses. EGGD was observed in 9/11 (82%; 95% CI, 53-96%) endurance horses and 9/15 (60%; 95% CI, 35-81%) eventing horses. The presence or severity of ESGD was unrelated to the presence or severity of EGGD. ACTH stimulation induced a larger increase in cortisol concentration in horses with moderate EGGD than in horses with mild EGGD. Cortisol concentration during the entire sampling period (total increase in cortisol concentration during the entire sampling period [dAUC], 31.1±6.4ng/mL) and the highest measured concentration at a single time point (maximal increase in cortisol concentration [dMAX], 10.3±2.3ng/mL) were increased (P=0.005 and P=0.038, respectively), indicating that horses with glandular gastric disease exhibited increased adrenocortical responses to ACTH stimulation. These results suggest that EGGD might be associated with an enhanced adrenocortical sensitivity. Further investigations are warranted to confirm the association between adrenocortical sensitivity and EGGD and to elucidate the pathophysiological mechanisms involved. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Estimation of mean glandular dose for patients who undergo mammography and studying the factors affecting it

    Science.gov (United States)

    Barzanje, Sana L. N. H.; Harki, Edrees M. Tahir Nury

    2017-09-01

    The objective of this study was to determine mean glandular dose (MGD) during diagnostic mammography. This study was done in two hospitals in Hawler city in Kurdistan -region /Iraq, the exposure parameters kVp and mAs was recorded for 40 patients under go mammography. The MGD estimated by multiplied ESD with normalized glandular dose (Dn). The ESD measured indirectly by measuring output radiation mGy/mAs by using PalmRAD 907 as a suitable detector (Gigger detector).the results; shown that the mean and its standard deviation of MGD for Screen Film Mammography and Digital Mammography are (0.95±0.18)mGy and (0.99±0.26)mGy, respectively. And there is a significant difference between MGD for Screen Film Mammography and Digital Mammography views (p≤0. 05). Also the mean value and its standard deviation of MGD for screen film mammography is (0.96±0.21) for CC projection and (1.03±0.3) mGy for MLO projection, but mean value and its standard deviation evaluated of MGD for digital mammography is (0.92±0.17) mGy for CC projection and (0.98±0.2) mGy for MLO projection. As well as, the effect of kVp and mAs in MGD were studied, shows that in general as kVp and mAs increased the MGD increased accordingly in both of mammography systems.

  19. PTEN phosphatase-independent maintenance of glandular morphology in a predictive colorectal cancer model system.

    Science.gov (United States)

    Jagan, Ishaan C; Deevi, Ravi K; Fatehullah, Aliya; Topley, Rebecca; Eves, Joshua; Stevenson, Michael; Loughrey, Maurice; Arthur, Kenneth; Campbell, Frederick Charles

    2013-11-01

    Organotypic models may provide mechanistic insight into colorectal cancer (CRC) morphology. Three-dimensional (3D) colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN) coupling of cell division cycle 42 (cdc42) to atypical protein kinase C (aPKC). This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM) orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3) were ineffective. The isolated PTEN C2 domain (C2) accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na(+)/H(+) exchanger regulatory factor-1 (NHERF-1) in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  20. PTEN Phosphatase-Independent Maintenance of Glandular Morphology in a Predictive Colorectal Cancer Model System

    Directory of Open Access Journals (Sweden)

    Ishaan C. Jagan

    2013-11-01

    Full Text Available Organotypic models may provide mechanistic insight into colorectal cancer (CRC morphology. Three-dimensional (3D colorectal gland formation is regulated by phosphatase and tensin homologue deleted on chromosome 10 (PTEN coupling of cell division cycle 42 (cdc42 to atypical protein kinase C (aPKC. This study investigated PTEN phosphatase-dependent and phosphatase-independent morphogenic functions in 3D models and assessed translational relevance in human studies. Isogenic PTEN-expressing or PTEN-deficient 3D colorectal cultures were used. In translational studies, apical aPKC activity readout was assessed against apical membrane (AM orientation and gland morphology in 3D models and human CRC. We found that catalytically active or inactive PTEN constructs containing an intact C2 domain enhanced cdc42 activity, whereas mutants of the C2 domain calcium binding region 3 membrane-binding loop (M-CBR3 were ineffective. The isolated PTEN C2 domain (C2 accumulated in membrane fractions, but C2 M-CBR3 remained in cytosol. Transfection of C2 but not C2 M-CBR3 rescued defective AM orientation and 3D morphogenesis of PTEN-deficient Caco-2 cultures. The signal intensity of apical phospho-aPKC correlated with that of Na+/H+ exchanger regulatory factor-1 (NHERF-1 in the 3D model. Apical NHERF-1 intensity thus provided readout of apical aPKC activity and associated with glandular morphology in the model system and human colon. Low apical NHERF-1 intensity in CRC associated with disruption of glandular architecture, high cancer grade, and metastatic dissemination. We conclude that the membrane-binding function of the catalytically inert PTEN C2 domain influences cdc42/aPKC-dependent AM dynamics and gland formation in a highly relevant 3D CRC morphogenesis model system.

  1. Detection of cervical intraepithelial neoplasia in women with atypical squamous or glandular cells of undetermined significance cytology: a prospective study

    NARCIS (Netherlands)

    Wensveen, Celesta; Kagie, Marjolein; Veldhuizen, Roel; de Groot, Christianne; Denny, Lynette; Zwinderman, Koos; Trimbos, Baptist

    2003-01-01

    (1) To assess the prevalence of histologically confirmed cervical intraepithelial neoplasia in patients with cervical smears diagnosed as atypical squamous or glandular cells of undetermined significance. (2) To evaluate the role of colposcopy and the presence of human papillomavirus in detecting

  2. Abnormal ion content, hydration and granule expansion of the secretory granules from cystic fibrosis airway glandular cells

    International Nuclear Information System (INIS)

    Baconnais, S.; Delavoie, F.; Zahm, J.M.; Milliot, M.; Terryn, C.; Castillon, N.; Banchet, V.; Michel, J.; Danos, O.; Merten, M.; Chinet, T.; Zierold, K.; Bonnet, N.; Puchelle, E.; Balossier, G.

    2005-01-01

    The absence or decreased expression of cystic fibrosis transmembrane conductance regulator (CFTR) induces increased Na + absorption and hyperabsorption of the airway surface liquid (ASL) resulting in a dehydrated and hyperviscous ASL. Although the implication of abnormal airway submucosal gland function has been suggested, the ion and water content in the Cystic Fibrosis (CF) glandular secretory granules, before exocytosis, is unknown. We analyzed, in non-CF and CF human airway glandular cell lines (MM-39 and KM4, respectively), the ion content in the secretory granules by electron probe X-ray microanalysis and the water content by quantitative dark field imaging on freeze-dried cryosections. We demonstrated that the ion content (Na + , Mg 2+ , P, S and Cl - ) is significantly higher and the water content significantly lower in secretory granules from the CF cell line compared to the non-CF cell line. Using videomicroscopy, we observed that the secretory granule expansion was deficient in CF glandular cells. Transfection of CF cells with CFTR cDNA or inhibition of non-CF cells with CFTR inh -172, respectively restored or decreased the water content and granule expansion, in parallel with changes in ion content. We hypothesize that the decreased water and increased ion content in glandular secretory granules may contribute to the dehydration and increased viscosity of the ASL in CF

  3. Breast Pain

    Science.gov (United States)

    ... result in the development of breast cysts. Breast trauma, prior breast surgery or other factors localized to the breast can lead to breast pain. Breast pain may also start outside the breast — in the chest wall, muscles, joints or heart, for example — and ...

  4. Breast Radiation Dose With CESM Compared With 2D FFDM and 3D Tomosynthesis Mammography.

    Science.gov (United States)

    James, Judy R; Pavlicek, William; Hanson, James A; Boltz, Thomas F; Patel, Bhavika K

    2017-02-01

    We aimed to compare radiation dose received during contrast-enhanced spectral mammography (CESM) using high- and low-energy projections with radiation dose received during 2D full field digital mammography (FFDM) and 3D tomosynthesis on phantoms and patients with varying breast thickness and density. A single left craniocaudal projection was chosen to determine the doses for 6214 patients who underwent 2D FFDM, 3662 patients who underwent 3D tomosynthesis, and 173 patients who underwent CESM in this retrospective study. Dose measurements were also collected in phantoms with composition mimicking nondense and dense breast tissue. Average glandular dose (AGD) ± SD was 3.0 ± 1.1 mGy for CESM exposures at a mean breast thickness of 63 mm. At this thickness, the dose was 2.1 mGy from 2D FFDM and 2.5 mGy from 3D tomosynthesis. The nondense phantom had a mean AGD of 1.0 mGy with 2D FFDM, 1.3 mGy with 3D tomosynthesis, and 1.6 mGy with CESM. The dense breast phantom had a mean AGD of 1.3 mGy with 2D FFDM, 1.4 mGy with 3D tomosynthesis, and 2.1 mGy with CESM. At a compressed thickness of 4.5 cm, radiation exposure from CESM was approximately 25% higher in dense breast phantoms than in nondense breast phantoms. The dose in the dense phantom at a compressed thickness of 6 cm was approximately 42% higher than the dose in the nondense phantom at a compressed thickness of 4.5 cm. CESM was found to increase AGD at a mean breast thickness of 63 mm by approximately 0.9 mGy and 0.5 mGy compared with 2D FFDM and 3D tomosynthesis, respectively. Of note, CESM provides a standard image (similar to 2D FFDM) that is obtained using the low-energy projection. Overall, the AGD from CESM falls below the dose limit of 3 mGy set by Mammography Quality Standards Act regulations.

  5. SU-F-J-09: Radioactive Seed Localization for Breast Lumpectomy - Towards Optimization

    Energy Technology Data Exchange (ETDEWEB)

    Aima, M; Viscariello, N; Patton, T; Bednarz, B [University of Wisconsin, Madison, WI (United States)

    2016-06-15

    Purpose: The aim of this work is to propose a method to optimize radioactive source localization (RSL) for non-palpable breast cancer surgery. RSL is commonly used as a guiding technique during surgery for excision of non-palpable tumors. A collimated hand-held detector is used to localize radioactive sources implanted in tumors. Incisions made by the surgeon are based on maximum observed detector counts, and tumors are subsequently resected based on an arbitrary estimate of the counts expected at the surgical margin boundary. This work focuses on building a framework to predict detector counts expected throughout the procedure to improve surgical margins. Methods: A gamma detection system called the Neoprobe GDS was used for this work. The probe consists of a cesium zinc telluride crystal and a collimator. For this work, an I-125 Best Medical model 2301 source was used. The source was placed in three different phantoms, a PMMA, a Breast (25%- glandular tissue/75%- adipose tissue) and a Breast (75-25) phantom with a backscatter thickness of 6 cm. Counts detected by the probe were recorded with varying amounts of phantom thicknesses placed on top of the source. A calibration curve was generated using MATLAB based on the counts recorded for the calibration dataset acquired with the PMMA phantom. Results: The observed detector counts data used as the validation set was accurately predicted to within ±3.2%, ±6.9%, ±8.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. The average difference between predicted and observed counts was −0.4%, 2.4%, 1.4% with a standard deviation of 1.2 %, 1.8%, 3.4% for the PMMA, Breast (75-25), Breast (25–75) phantom respectively. Conclusion: The results of this work provide a basis for characterization of a detector used for RSL. Counts were predicted to within ±9% for three different phantoms without the application of a density correction factor.

  6. The effect of breast compression on mass conspicuity in digital mammography

    International Nuclear Information System (INIS)

    Saunders, Robert S. Jr; Samei, Ehsan

    2008-01-01

    This study analyzed how the inherent quality of diagnostic information in digital mammography could be affected by breast compression. A digital mammography system was modeled using a Monte Carlo algorithm based on the Penelope program, which has been successfully used to model several medical imaging systems. First, the Monte Carlo program was validated against previous measurements and simulations. Once validated, the Monte Carlo software modeled a digital mammography system by tracking photons through a voxelized software breast phantom, containing anatomical structures and breast masses, and following photons until they were absorbed by a selenium-based flat-panel detector. Simulations were performed for two compression conditions (standard compression and 12.5% reduced compression) and three photon flux conditions (constant flux, constant detector signal, and constant glandular dose). The results showed that reduced compression led to higher scatter fractions, as expected. For the constant photon flux condition, decreased compression also reduced glandular dose. For constant glandular dose, the SdNR for a 4 cm breast was 0.60±0.11 and 0.62±0.11 under standard and reduced compressions, respectively. For the 6 cm case with constant glandular dose, the SdNR was 0.50±0.11 and 0.49±0.10 under standard and reduced compressions, respectively. The results suggest that if a particular imaging system can handle an approximately 10% increase in total tube output and 10% decrease in detector signal, breast compression can be reduced by about 12% in terms of breast thickness with little impact on image quality or dose.

  7. Digital breast tomosynthesis; Digitale Tomosynthese der Brust

    Energy Technology Data Exchange (ETDEWEB)

    Haegele, Julian; Barkhausen, Joerg [Universtiaetsklinikum Schleswig-Holstein, Luebeck (Germany). Klinik fuer Radiologie und Nuklearmedizin; Pursche, Telja [Universtiaetsklinikum Schleswig-Holstein, Luebeck (Germany). Brustzentrum; Schaefer, Fritz K.W. [Universtiaetsklinikum Schleswig-Holstein, Kiel (Germany). Bereich Mammadiagnostik und Intervention

    2015-09-15

    In digital breast tomosynthesis a digital tomographic data set with a very high spatial resolution is reconstructed from low-dose projections collected over a limited rotation angle. This allows a very detailed assessment of e. g. masses and architectural distortions. The average glandular dose is comparable to 2 D mammography. First clinical studies demonstrated that tomosynthesis is able to supply important additional information in suspicious mammographic findings. In comparison to projection mammography, tomosynthesis shows an at least comparable diagnostic accuracy. In everyday practice, tomosynthesis is currently mostly used for further evaluation of suspicious findings in mammography.

  8. NON-INFLAMMATORY BENIGN BREAST DISEASES (NIBBD: CONFUSING SURGICAL DISORDERS OF BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Somashekhar V. Hiremath

    2016-08-01

    Full Text Available BACKGROUND Benign Breast diseases are of unknown aetiology, they could be inflammatory or non-inflammatory disorders of breast disease. Among these, NIBBD is a most confusing surgical disorder, diagnosis should be made at least after three assessments. AIM  To evaluate the prevalence of NIBBD.  Clinical analysis of NIBBD in women and reproductive age group between 20-40 years.  To prevent radical breast surgery in NIBBD.  To know about benign breast lesions in males excluding gynaecomastia. MATERIALS AND METHODS A clinicopathological study of NIBBD was taken in KIMS Hospital, Hubli, a tertiary care government hospital between June 2014 to June 2015. A total of 56 cases were selected of which 51 cases were submitted for clinicopathological study. RESULTS Increase incidents of fibroadenoma in females, in young age group, is noticed due to early menarche, early marriage, multiparity, fibrocystic diseases involvement at the age of 35 years, usually appear on either side of the breast. Moderate loss of glandular tissue is accelerated and replaced by connective tissue, hence fibrocystic diseases appear at late age group. Gynaecomastia is the only NIBBD, seen unilaterally in males. CONCLUSION NIBBD is more common in childbearing age group i.e. 15 to 45 years of age. Triple assessment is the choice of diagnosis, imaging modality being USG of the breast and mammography in suspected cases of malignancy. Most of the patients require surgical intervention and remodelling of the Breast, according to the volume loss of breast tissue.

  9. Dual-energy contrast-enhanced breast tomosynthesis: optimization of beam quality for dose and image quality

    International Nuclear Information System (INIS)

    Samei, Ehsan; Saunders, Robert S Jr

    2011-01-01

    Dual-energy contrast-enhanced breast tomosynthesis is a promising technique to obtain three-dimensional functional information from the breast with high resolution and speed. To optimize this new method, this study searched for the beam quality that maximized image quality in terms of mass detection performance. A digital tomosynthesis system was modeled using a fast ray-tracing algorithm, which created simulated projection images by tracking photons through a voxelized anatomical breast phantom containing iodinated lesions. The single-energy images were combined into dual-energy images through a weighted log subtraction process. The weighting factor was optimized to minimize anatomical noise, while the dose distribution was chosen to minimize quantum noise. The dual-energy images were analyzed for the signal difference to noise ratio (SdNR) of iodinated masses. The fast ray-tracing explored 523 776 dual-energy combinations to identify which yields optimum mass SdNR. The ray-tracing results were verified using a Monte Carlo model for a breast tomosynthesis system with a selenium-based flat-panel detector. The projection images from our voxelized breast phantom were obtained at a constant total glandular dose. The projections were combined using weighted log subtraction and reconstructed using commercial reconstruction software. The lesion SdNR was measured in the central reconstructed slice. The SdNR performance varied markedly across the kVp and filtration space. Ray-tracing results indicated that the mass SdNR was maximized with a high-energy tungsten beam at 49 kVp with 92.5 μm of copper filtration and a low-energy tungsten beam at 49 kVp with 95 μm of tin filtration. This result was consistent with Monte Carlo findings. This mammographic technique led to a mass SdNR of 0.92 ± 0.03 in the projections and 3.68 ± 0.19 in the reconstructed slices. These values were markedly higher than those for non-optimized techniques. Our findings indicate that dual

  10. Breast internal dose measurements in a physical thoracic phantom

    Energy Technology Data Exchange (ETDEWEB)

    Silva, S.D.; Oliveira, M.A.; Castro, A.L.S.; Dias, H.G.; Nogueira, L.B.; Campos, T.P.R., E-mail: sadonatosilva@hotmail.com [Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Departamento de Engenharia Nuclear; Hospital das Clinicas de Uberlandia, MG (Brazil). Departamento de Oncologia; Universidade Federal de Minas Gerais (UFMG), Belo Horizonte, MG (Brazil). Anatomia e Departamento de Imagem

    2017-10-01

    Radiotherapy is a cancer treatment intended to deposit the entire prescribed dose homogeneously into a target volume in order to eliminate the tumor and to spare the surrounding healthy tissues. This paper aimed to provide a dosimetric comparison between the treatment planning system (TPS) ECLIPSE from Varian Medical Systems and the internal dosimetric measurements in a breast phantom. The methodology consisted in performing a 3D conformal radiotherapy planning with two tangential opposite parallel fields applied to the synthetic breast in a thoracic phantom. The irradiation was reproduced in the Varian Linear accelerator, model SL - 20 Precise, 6 MV energy. EBT2 Radiochromic films, placed into the glandular equivalent tissue of the breast, were used to measure the spatial dose distribution. The absorbed dose was compared to those values predicted by the treatment planning system; besides, the dosimetric uncertainties were analyzed. The modal absorbed dose was in agreement with the prescribed value of 180 cGy, although few high dose points between 180 and 220 cGy were detected. The findings suggested a non-uniform dose distribution in the glandular tissue of the synthetic breast, similar to those found in the TPS, associated with the irregular anatomic breast shape and presence of inhomogeneities next to the thoracic wall generated by the low lung density. (author)

  11. Cervical squamous and glandular intraepithelial neoplasia: identification and current management approaches Neoplasia intraepitelial cervical escamosa y glandular: identificación y estrategias de manejo

    Directory of Open Access Journals (Sweden)

    V Cecil Wright

    2003-01-01

    realiza mediante la biopsia de cono, y el espécimen debe tener márgenes negativos para enfermedad. La histerectomía es un tratamiento probable, a menos que la fertilidad esté siendo buscada. La escisión, particularmente por electrocirugía (loop, puede interferir con la interpretación histológica en algunos casos o de ambos, particularmente en enfermedades escamosas y adenocarcinoma in situ. En este artículo se describe ampliamente el manejo de la neoplasia intraepitelial escamosa y glandular.

  12. Células glandulares atípicas em esfregaços cervicovaginais: significância e aspectos atuais Atypical glandular cells in cervical smears: significance and current aspects

    Directory of Open Access Journals (Sweden)

    Adriana Bittencourt Campaner

    2007-02-01

    Full Text Available Células glandulares atípicas (AGC em esfregaços cervicovaginais são achados citológicos raros, porém de significado representativo. Sua incidência varia, na literatura, de 0,08% a 0,81%. O sistema Bethesda de 2001 classifica estas lesões glandulares como AGCs sem outras especificações, AGCs provavelmente neoplásicas, adenocarcinoma cervical in situ (AIS e adenocarcinoma invasivo. Das mulheres portadoras de AGC, grande parte não apresentará qualquer tipo de alteração histológica em avaliação subseqüente. Entretanto, em 17,4% a 62,2% dos casos serão encontradas lesões histológicas significativas, como neoplasias intra-epiteliais cervicais, AIS, neoplasias escamosas e glandulares, cervicais e endometriais, bem como neoplasias de outras localizações. O risco de doença significativa está relacionado à subdivisão de AGC encontrada. Em virtude da elevada probabilidade de anormalidades histológicas significativas em casos de AGC, a simples repetição citológica é insuficiente para o seguimento dessa condição. Esta atualização descreve a epidemiologia, a avaliação e a conduta das pacientes portadoras dessa anormalidade citológica.Atypical glandular cells (AGC on cervical smears are unusual but important cytologic diagnosis. The incidence of AGC ranges from 0.08% to 0.81 % of all cervical smears tests. The 2001 Bethesda System nomenclature classifies these glandular lesions as AGC not otherwise specified, AGC favor neoplasia, endocervical adenocarcinoma in situ (AIS and invasive adenocarcinoma. Of women with AGC smears, a great number will have no histologic abnormalities on further evaluation. However, 17.4% to 62.2% are found to have significant histologic lesions such as cervical intraepithelial neoplasia, AIS, squamous and glandular cancers from sites farther the cervix and endometrium. The risk of significant disease is related to the AGC subclassification that was found. Because of the high likelihood that AGC

  13. Papel da 2-tridecanona e dos tricomas glandulares tipo VI na resistência do tomateiro a Tuta absoluta Role of 2-tridecanone and type VI glandular trichome on tomato resistance to Tuta absoluta

    Directory of Open Access Journals (Sweden)

    Elsa Gilardón

    2001-07-01

    Full Text Available O metabólito secundário 2-tridecanona, secretado pelos tricomas glandulares tipo VI das folhas de tomateiro silvestre, Lycopersicon hirsutum L., confere-lhe resistência a uma grande variedade de insetos, inclusive a traça-do-tomateiro, Tuta absoluta (Meyrick. O objetivo do trabalho foi avaliar a concentração de 2- tridecanona, a densidade de tricomas glandulares tipo VI e o grau de infestação da traça-do-tomateiro na cultivar suscetível 'Uco Plata' (Lycopersicon esculentum Mill., na linhagem resistente PI 134417 (L. hirsutum f. glabratum e em suas progênies F1 e F2. Foram avaliadas ainda as possíveis associações entre a concentração de 2-tridecanona, a densidade de tricomas glandulares tipo VI e o grau de infestação da traça-do-tomateiro. O grau médio de infestação da traça-do-tomateiro em 'Uco Plata' foi significativamente superior ao obtido em PI 134417. Ainda que a concentração de 2-tridecanona tenha sido significativamente superior no parental resistente, a presença deste metabólito somente explicaria parcialmente a resistência (R² = 8,17%. Não se detectaram diferenças significativas na densidade de tricomas tipo VI entre o parental suscetível e o resistente. Este comportamento ocorreu independentemente do conteúdo de 2-tridecanona e do grau de infestação da traça-do-tomateiro.The secondary metabolite 2-tridecanone, secreted by the type VI glandular trichomes present in the leaves of Lycopersicon hirsutum L., make it resistant to a great variety of insects, including the tomato pinworm, Tuta absoluta (Meyrick. The 2-tridecanone concentration, the type VI glandular trichome densities and the pinworm infestation degree were evaluated on the Lycopersicon esculentum Mill. susceptible cultivar 'Uco Plata', on the Lycopersicon hirsutum f. glabratum resistant accession PI 134417 and on their F1 and F2. The mean infestation degree with pinworm larvae was significantly higher in 'Uco Plata' than in PI 134417. The 2

  14. Determination of the Elasticity of Breast Tissue during the Menstrual Cycle Using Real-Time Shear Wave Elastography.

    Science.gov (United States)

    Li, Xiang; Wang, Jian-Nan; Fan, Zhi-Ying; Kang, Shu; Liu, Yan-Jun; Zhang, Yi-Xia; Wang, Xue-Mei

    2015-12-01

    We examined breast tissue elasticity during the menstrual cycle using real-time shear wave elastography (RT-SWE), a recent technique developed for soft tissue imaging. Written informed consent for RT-SWE was obtained from all eligible patients, who were healthy women aged between 19 and 52 y. Young's moduli of the breast tissue in the early follicular, late phase and luteal phase were compared. There were no significant differences in the mean, maximum and minimum elasticity values (Emean, Emax and Emin) and standard deviation (ESD). RT-SWE of glandular tissue revealed that ESD was increased in the early follicular phase compared with the luteal phase. Means ± SD of Emin, Emax and Emean in glandular tissue were 5.174 ± 2.138, 8.308 ± 3.166 and 6.593 ± 2.510, respectively, and in adipose tissue, 3.589 ± 2.083, 6.733 ± 3.522 and 4.857 ± 2.564, respectively. There were no significant differences in stiffness between glandular and adipose tissues throughout the menstrual cycle, but glandular tissue stiffness was lower in the luteal phase than in the early follicular phase. On the basis of these observations in normal healthy women, we believe we have obtained sufficient information to establish the baseline changes in human breast elasticity during the menstrual cycle. In the future, we intend to compare the elasticity values of healthy breast tissue with those of breast tissue affected by various pathologies. Our results reveal the significant potential of RT-SWE in the rapid and non-invasive clinical diagnosis of breast diseases, such as breast cancers. Copyright © 2015 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  15. Differentiating between endocervical glandular neoplasia and high grade squamous intraepithelial lesions in endocervical crypts: cytological features in ThinPrep and SurePath cervical cytology samples.

    Science.gov (United States)

    Thiryayi, Sakinah A; Marshall, Janet; Rana, Durgesh N

    2009-05-01

    A recent audit at our institution revealed a higher number of cases diagnosed as endocervical glandular neoplasia on ThinPrep (TP) cervical cytology samples (9 cases) as opposed to SurePath (SP) (1 case), which on histology showed only high-grade cervical intraepithelial neoplasia (CIN) with endocervical crypt involvement (CI). We attempted to ascertain the reasons for this finding by reviewing the available slides of these cases, as well as slides of cases diagnosed as glandular neoplasia on cytology and histology; cases diagnosed as high-grade squamous intraepithelial lesions (HSIL) on cytology which had CIN with CI on histology and cases with mixed glandular and squamous abnormalities diagnosed both cytologically and histologically. Single neoplastic glandular cells and short pseudostratified strips were more prevalent in SP than TP with the cell clusters in glandular neoplasia 3-4 cells thick, in contrast to the dense crowded centre of cell groups in HSIL with CI. The cells at the periphery of groups can be misleading. Cases with HSIL and glandular neoplasia have a combination of the features of each entity in isolation. The diagnosis of glandular neoplasia remains challenging and conversion from conventional to liquid based cervical cytology requires a period of learning and adaptation, which can be facilitated by local audit and review of the cytology slides in cases with a cytology-histology mismatch. (c) 2009 Wiley-Liss, Inc.

  16. Identification, functional characterization and developmental regulation of sesquiterpene synthases from sunflower capitate glandular trichomes

    Directory of Open Access Journals (Sweden)

    Ro Dae-Kyun

    2009-07-01

    Full Text Available Abstract Background Sesquiterpene lactones are characteristic metabolites of Asteraceae (or Compositae which often display potent bioactivities and are sequestered in specialized organs such as laticifers, resin ducts, and trichomes. For characterization of sunflower sesquiterpene synthases we employed a simple method to isolate pure trichomes from anther appendages which facilitated the identification of these genes and investigation of their enzymatic functions and expression patterns during trichome development. Results Glandular trichomes of sunflower (Helianthus annuus L. were isolated, and their RNA was extracted to investigate the initial steps of sesquiterpene lactone biosynthesis. Reverse transcription-PCR experiments led to the identification of three sesquiterpene synthases. By combination of in vitro and in vivo characterization of sesquiterpene synthase gene products in Escherichia coli and Saccharomyces cerevisiae, respectively, two enzymes were identified as germacrene A synthases, the key enzymes of sesquiterpene lactone biosynthesis. Due to the very low in vitro activity, the third enzyme was expressed in vivo in yeast as a thioredoxin-fusion protein for functional characterization. In in vivo assays, it was identified as a multiproduct enzyme with the volatile sesquiterpene hydrocarbon δ-cadinene as one of the two main products with α-muuorlene, β-caryophyllene, α-humulene and α-copaene as minor products. The second main compound remained unidentified. For expression studies, glandular trichomes from the anther appendages of sunflower florets were isolated in particular developmental stages from the pre- to the post-secretory phase. All three sesquiterpene synthases were solely upregulated during the biosynthetically active stages of the trichomes. Expression in different aerial plant parts coincided with occurrence and maturity of trichomes. Young roots with root hairs showed expression of the sesquiterpene synthase genes

  17. Células glandulares atípicas e câncer de colo uterino: revisão sistemática Atypical glandular cells and cervical cancer: systematic review

    Directory of Open Access Journals (Sweden)

    Juliana Pedrosa de Holanda Marques

    2011-04-01

    Full Text Available Atipias de células glandulares em esfregaços cervicovaginais é um achado citológico na rotina de rastreamento do câncer cervical, que aumentou nas últimas décadas. Sua constatação é importante clinicamente, pois é alta a percentagem de casos associados com doença cervical e endometrial de alto grau e câncer. Este trabalho avaliou, por meio de uma revisão sistemática, estudos que investigaram o perfil das lesões de colo uterino em avaliações histológicas de seguimento de pacientes já diagnosticadas com células glandulares atípicas. Foram excluídos os estudos cuja investigação diagnóstica não incluísse o diagnóstico histopatológico. Realizou-se uma busca abrangente de publicações no período de 1966 a 2009, nas bases do LILACS, SciELO, PubMed/Medline e Old Medline. Os artigos omitidos na busca eletrônica também foram incluídos. Estavam de acordo com os critérios de inclusão 19 artigos, que foram selecionados. Este estudo tem como objetivo avaliar se a atipia celular glandular observada inicialmente na citologia relacionava-se histologicamente com a presença de lesões benignas, pré-neoplásicas ou neoplásicas. Dos 19 estudos selecionados, 11 mostraram maior correlação entre atipia glandular com patologias benignas e seis com lesões escamosas pré-malignas.Atypical glandular cells are a common finding in cervical cytology in cervical cancer screening and its occurrence has increased in the last decades. The identification of these cells is clinically very important due to its association with cervical and endometrial dysplasic lesions and cancer. Using a systematic approach, this article reviewed studies investigating cervical lesions that are characteristic in patients previously diagnosed as having atypical glandular cells. Studies in which diagnostic investigation did not include histopathological diagnosis were excluded. A comprehensive search for available material in LILACS, SciELO, PubMed/ Medline

  18. Object characterization simulator for estimating compressed breast during mammography

    International Nuclear Information System (INIS)

    Pinheiro, Luciana de J.S.; Rio, Margarita Chevalier del

    2011-01-01

    The measurement of the thickness of a compressed breast during the mammography test is necessary in order to calculate the glandular dose in mammography procedures, in an analysis of risk/benefit, given that the target organ in these procedures is highly sensitive to ionising radiation. However, mammography is a test of utmost importance in diagnosis. In theory, it may be possible to calculate the thickness of the compressed breast through the measurements of the focus object distance by using projections of radio opaque objects fixed to the compression tray. The facilities of the Laboratory of Applied Radioprotection to Mammography - LARAM were used for this study, as well as breast simulators with well defined thickness, in the assembly of the techniques for the measurement of the thickness of the compressed breast. The results showed that it is possible to determine this thickness through calculations and simulators through this method which is susceptible to be adequate to the dosimetry. (author)

  19. Fully iterative scatter corrected digital breast tomosynthesis using GPU-based fast Monte Carlo simulation and composition ratio update

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyungsang; Ye, Jong Chul, E-mail: jong.ye@kaist.ac.kr [Bio Imaging and Signal Processing Laboratory, Department of Bio and Brain Engineering, KAIST 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Lee, Taewon; Cho, Seungryong [Medical Imaging and Radiotherapeutics Laboratory, Department of Nuclear and Quantum Engineering, KAIST 291, Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of); Seong, Younghun; Lee, Jongha; Jang, Kwang Eun [Samsung Advanced Institute of Technology, Samsung Electronics, 130, Samsung-ro, Yeongtong-gu, Suwon-si, Gyeonggi-do, 443-803 (Korea, Republic of); Choi, Jaegu; Choi, Young Wook [Korea Electrotechnology Research Institute (KERI), 111, Hanggaul-ro, Sangnok-gu, Ansan-si, Gyeonggi-do, 426-170 (Korea, Republic of); Kim, Hak Hee; Shin, Hee Jung; Cha, Joo Hee [Department of Radiology and Research Institute of Radiology, Asan Medical Center, University of Ulsan College of Medicine, 88 Olympic-ro, 43-gil, Songpa-gu, Seoul, 138-736 (Korea, Republic of)

    2015-09-15

    Purpose: In digital breast tomosynthesis (DBT), scatter correction is highly desirable, as it improves image quality at low doses. Because the DBT detector panel is typically stationary during the source rotation, antiscatter grids are not generally compatible with DBT; thus, a software-based scatter correction is required. This work proposes a fully iterative scatter correction method that uses a novel fast Monte Carlo simulation (MCS) with a tissue-composition ratio estimation technique for DBT imaging. Methods: To apply MCS to scatter estimation, the material composition in each voxel should be known. To overcome the lack of prior accurate knowledge of tissue composition for DBT, a tissue-composition ratio is estimated based on the observation that the breast tissues are principally composed of adipose and glandular tissues. Using this approximation, the composition ratio can be estimated from the reconstructed attenuation coefficients, and the scatter distribution can then be estimated by MCS using the composition ratio. The scatter estimation and image reconstruction procedures can be performed iteratively until an acceptable accuracy is achieved. For practical use, (i) the authors have implemented a fast MCS using a graphics processing unit (GPU), (ii) the MCS is simplified to transport only x-rays in the energy range of 10–50 keV, modeling Rayleigh and Compton scattering and the photoelectric effect using the tissue-composition ratio of adipose and glandular tissues, and (iii) downsampling is used because the scatter distribution varies rather smoothly. Results: The authors have demonstrated that the proposed method can accurately estimate the scatter distribution, and that the contrast-to-noise ratio of the final reconstructed image is significantly improved. The authors validated the performance of the MCS by changing the tissue thickness, composition ratio, and x-ray energy. The authors confirmed that the tissue-composition ratio estimation was quite

  20. Volatiles and Nonvolatiles in Flourensia campestris Griseb. (Asteraceae), How Much Do Capitate Glandular Trichomes Matter?

    Science.gov (United States)

    Piazza, Leonardo A; López, Daniela; Silva, Mariana P; López Rivilli, Marisa J; Tourn, Mónica G; Cantero, Juan J; Scopel, Ana L

    2018-03-01

    The distribution and ultrastructure of capitate glandular trichomes (GTs) in Flourensia species (Asteraceae) have been recently elucidated, but their metabolic activity and potential biological function remain unexplored. Selective nonvolatile metabolites from isolated GTs were strikingly similar to those found on leaf surfaces. The phytotoxic allelochemical sesquiterpene (-)-hamanasic acid A ((-)-HAA) was the major constituent (ca. 40%) in GTs. Although GTs are quaternary ammonium compounds (QACs)-accumulating species, glycine betaine was not found in GTs; it was only present in the leaf mesophyll. Two (-)-HAA accompanying surface secreted products: compounds 4-hydroxyacetophenone (piceol; 1) and 2-hydroxy-5-methoxyacetophenone (2), which were isolated and fully characterized (GC/MS, NMR), were present in the volatiles found in GTs. The essential oils of fresh leaves revealed ca. 33% monoterpenes, 26% hydrocarbon- and 30% oxygenated sesquiterpenes, most of them related to cadinene and bisabolene derivatives. Present results suggest a main role of GTs in determining the volatile and nonvolatile composition of F. campestris leaves. Based on the known activities of the compounds identified, it can be suggested that GTs in F. campestris would play key ecological functions in plant-pathogen and plant-plant interactions. In addition, the strikingly high contribution of compounds derived from cadinene and bisabolene pathways, highlights the potential of this species as a source of high-valued bioproducts. © 2018 Wiley-VHCA AG, Zurich, Switzerland.

  1. 20-year Follow-up of Recurrent Glandular Odontogenic Cyst Mimicking a Periapical Lesion.

    Science.gov (United States)

    de Freitas Silva, Brunno Santos; Yamamoto-Silva, Fernanda Paula; Sena-Filho, Marcondes; Silva Sant'Ana, Simone Sousa; Mariano-Júnior, Wilson José; de Almeida, Oslei Paes; Estrela, Carlos

    2017-11-01

    Periapical lesions usually are caused by root canal infection; nevertheless, other pathologies may eventually involve the tooth apex, making the correct diagnosis more difficult. Glandular odontogenic cysts (GOCs) are uncommon and, despite their cystic nature, may present an aggressive behavior and a high recurrence rate. This report describes a recurrent GOC mimicking a periapical lesion that was followed up for 20 years. A 45-year-old woman described tooth discomfort for several years in the anterior region of the mandible that was not exacerbated during eating or occlusion. Clinical examination revealed no signs of swelling, redness, or inflammation in the gingival or surrounding soft tissue. Nevertheless, periapical radiography showed a well-defined large radiolucent lesion in the periapical region of teeth #22, #23, #24, and #25. The pulp test confirmed that all these teeth were vital. An incisional biopsy was performed, and with the histopathological diagnosis of an odontogenic cyst, the lesion was enucleated surgically. After recurrence, the extensive periapical multilocular lesions were again surgically removed. Based on the microscopic findings, the final diagnosis was GOC. One year later, there were no signs of recurrence. GOCs associated with the root apex may mimic periapical inflammatory diseases. Clinical, radiographic, and histopathological findings are essential for the diagnosis of inconclusive radiolucent findings in the periapical region. Biopsy specimens should be sent to a specialized oral pathology laboratory. Copyright © 2017 American Association of Endodontists. Published by Elsevier Inc. All rights reserved.

  2. Glandular odontogenic cyst mimicking ameloblastoma in a 78 year old female: A case report

    International Nuclear Information System (INIS)

    Lee, Byung Do; Lee, Wan; Kwon, Kyung Hwan; Choi, Moon Ki; Choi, Eun Joo; Yoon, Jung Hoon

    2014-01-01

    Glandular odontogenic cyst (GOC) is a rare, potentially aggressive jaw lesion. The common radiographic features include a well-defined radiolucency with distinct borders, presenting a uni- or multilocular appearance. A cystic lesion in the posterior mandible of a 78-year-old female was incidentally found. Radiographs showed a unilocular lesion with a scalloped margin, external root resorption of the adjacent tooth, and cortical perforation. This lesion had changed from a small ovoid shape to a more expanded lesion in a period of four years. The small lesion showed unilocularity with a smooth margin and a well-defined border, but the expanded lesion produced cortical perforation and a lobulated margin. The provisional diagnosis was an ameloblastoma, whereas the histopathological examination revealed a GOC. This was a quite rare case, given that this radiographic change was observed in the posterior mandible of an elderly female. This case showed that a GOC can grow even in people in their seventies, changing from the unilocular form to an expanded, lobulated lesion. Here, we report a case of GOC with characteristic radiographic features.

  3. Glandular odontogenic cyst mimicking ameloblastoma in a 78 year old female: A case report

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Byung Do; Lee, Wan; Kwon, Kyung Hwan; Choi, Moon Ki; Choi, Eun Joo [College of Dentistry, Wonkwang University, Iksan (Korea, Republic of); Yoon, Jung Hoon [Dept. of Oral and Maxillofacial Pathology, College of Dentistry, Daejeon Dental Hospital, Wonkwang University, Daejeon (Korea, Republic of)

    2014-09-15

    Glandular odontogenic cyst (GOC) is a rare, potentially aggressive jaw lesion. The common radiographic features include a well-defined radiolucency with distinct borders, presenting a uni- or multilocular appearance. A cystic lesion in the posterior mandible of a 78-year-old female was incidentally found. Radiographs showed a unilocular lesion with a scalloped margin, external root resorption of the adjacent tooth, and cortical perforation. This lesion had changed from a small ovoid shape to a more expanded lesion in a period of four years. The small lesion showed unilocularity with a smooth margin and a well-defined border, but the expanded lesion produced cortical perforation and a lobulated margin. The provisional diagnosis was an ameloblastoma, whereas the histopathological examination revealed a GOC. This was a quite rare case, given that this radiographic change was observed in the posterior mandible of an elderly female. This case showed that a GOC can grow even in people in their seventies, changing from the unilocular form to an expanded, lobulated lesion. Here, we report a case of GOC with characteristic radiographic features.

  4. Basic elements for breast screening programs for Rwanda

    International Nuclear Information System (INIS)

    Abenanye, Emmanuel

    2015-02-01

    Mammography refers to the X-ray examination of the human breast, and is considered the single most important diagnostic tool in the early detection of breast cancer, which is by far the most common cancer among women. There is good evidence from clinical trials, that mammographic screening can reduce the breast cancer mortality with about 30%. The side effects include a small and age related risk of carcinogenesis due to the exposure of the glandular tissues in the breast to ionizing radiation. As for all X-ray examinations, and of special importance when investigating large populations of asymptomatic women, the relationship between radiation risk and diagnostic accuracy in mammography must be optimized. The overall objective of this thesis was to investigate and improve methods for average glandular dose (AGD) and image quality evaluation in mammography and provide some practical guidance. To assess the behavioral factors influencing breast screening the best set up of the mammography unit as well as equipment construction and the skills of people operating the machines in terms of the radiation protection screening programs. There has been doubts about the efficiency of so called service screening, i.e. routine screening programs (Sjonell and Stahle, 1999), but there is evidence suggesting a reduction of breast cancer mortality similar to that observed in the randomised trials (Duffy et al. 2002). However no study has been carried out in Rwanda of this nature to see what are the basic breast screening elements and behavioral elements that influence it. Therefore, the factors that influence women's mammography screening behavior is an important issue to be uncovered, in order to facilitate the understanding of such a behavior. This report sets out to investigate the factors that influence participation in mammography screening in Rwanda. Such an investigation aims to raise the awareness of health care providers of the factors that influence Rwanda's women

  5. Fibroblast growth factor 10-fibroblast growth factor receptor 2b mediated signaling is not required for adult glandular stomach homeostasis.

    Directory of Open Access Journals (Sweden)

    Allison L Speer

    Full Text Available The signaling pathways that are essential for gastric organogenesis have been studied in some detail; however, those that regulate the maintenance of the gastric epithelium during adult homeostasis remain unclear. In this study, we investigated the role of Fibroblast growth factor 10 (FGF10 and its main receptor, Fibroblast growth factor receptor 2b (FGFR2b, in adult glandular stomach homeostasis. We first showed that mouse adult glandular stomach expressed Fgf10, its receptors, Fgfr1b and Fgfr2b, and most of the other FGFR2b ligands (Fgf1, Fgf7, Fgf22 except for Fgf3 and Fgf20. Fgf10 expression was mesenchymal whereas FGFR1 and FGFR2 expression were mostly epithelial. Studying double transgenic mice that allow inducible overexpression of Fgf10 in adult mice, we showed that Fgf10 overexpression in normal adult glandular stomach increased epithelial proliferation, drove mucous neck cell differentiation, and reduced parietal and chief cell differentiation. Although a similar phenotype can be associated with the development of metaplasia, we found that Fgf10 overexpression for a short duration does not cause metaplasia. Finally, investigating double transgenic mice that allow the expression of a soluble form of Fgfr2b, FGF10's main receptor, which acts as a dominant negative, we found no significant changes in gastric epithelial proliferation or differentiation in the mutants. Our work provides evidence, for the first time, that the FGF10-FGFR2b signaling pathway is not required for epithelial proliferation and differentiation during adult glandular stomach homeostasis.

  6. Investigation of absorbed radiation dose in refraction-enhanced breast tomosynthesis by a Laue case analyser

    International Nuclear Information System (INIS)

    Sato, H.; Ando, M.; Shimao, D.

    2011-01-01

    An early diagnosis system for breast cancer using refraction-enhanced breast tomosynthesis is under development. Tomograms of breast specimens based on refraction-contrast were demonstrated using the simplest shift-and-add tomosynthesis algorithm. Raw projection image data of breast specimens for tomosynthesis were acquired for a total of 51 views over an angle of 50 deg., in increments of 1 deg., by rotating the object. The incident X ray was monochromatic synchrotron radiation with 20 keV. The purpose of this study was to estimate the absorbed dose of a new X-ray imaging method. As breast cancer almost always arises in glandular breast tissue, the average absorbed dose in such glandular tissue should be measured to estimate the radiation risk associated with mammography. The absorbed dose of the mammary gland due to monochromatic X rays was calculated by the Monte Carlo method, and the optimal X ray energy range for refraction-enhanced breast tomosynthesis was investigated through actual measurements. Compared with the conventional method, it was found to be below one-sixth per inspection. (authors)

  7. Fibroadenomas of the breast showing an ill-defined margin on ultrasonogram: Correlation with histopathologic findings

    International Nuclear Information System (INIS)

    Hwang, Ji Young; Choi, Hye Young; Shim, Sung Shine; Rhee, Chung Sik; Sung, Soon Hee

    2002-01-01

    To correlate the sonographic finding of ill-defined fibroadenoma with the histopathologic findings. Sonographic finding of forty nine surgically proven fibroadenomas were retrospectively correlated with histopathologic findings. We evaluated sonographic findings including the margin, shape, size and the echotexture of fibroadenoma. The histopathologic glandular structure, stromal type of fibroadenoma, type of the surrounding breast tissue and presence of interdigitation between fibroadenoma and the surrounding breast tissue were pathologically reviewed and analyzed statistically. Breast sonography of fibroadenomas demonstrated well-defined margin in 28 (57%) and ill-defined margin in 21 (43%) among 49 lesions. Histopathologically, the glandular structure and type of the surrounding breast tissue were not significantly different between well-defined and ill-defined fibroadenomas. The stromal type of fibroadenoma was sclerotic in 8 (29%) well-defined fibroadenomas while sclerotic in 15 (72%) of 21 ill-defined fibroadenomas,showing difference with a statistical significance between well-defined and ill-defined fibroadenomas (p<0.05). Twenty (71%) of 28 fibroadenomas with well-defined sonographic margins showed well-defined border between mass and the surrounding breast tissue, pathologically. Meanwhile, twenty (95%) of 21 fibroadenomas with ill-defined sonographic margins demonstrated interdigitation of the surrounding breast tissue and mass, exhibiting a statistical significance (p<0.005). Ill-defined margins of fibroadenomas on sonography represent the interdigitation of the surrounding breast tissue with a mass and is seen in the sclerotic stromal type of fibroadenomas.

  8. Fibroadenomas of the breast showing an ill-defined margin on ultrasonogram: Correlation with histopathologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Ji Young; Choi, Hye Young; Shim, Sung Shine; Rhee, Chung Sik; Sung, Soon Hee [Ewha Womans University College of Medicine, Seoul (Korea, Republic of)

    2002-12-15

    To correlate the sonographic finding of ill-defined fibroadenoma with the histopathologic findings. Sonographic finding of forty nine surgically proven fibroadenomas were retrospectively correlated with histopathologic findings. We evaluated sonographic findings including the margin, shape, size and the echotexture of fibroadenoma. The histopathologic glandular structure, stromal type of fibroadenoma, type of the surrounding breast tissue and presence of interdigitation between fibroadenoma and the surrounding breast tissue were pathologically reviewed and analyzed statistically. Breast sonography of fibroadenomas demonstrated well-defined margin in 28 (57%) and ill-defined margin in 21 (43%) among 49 lesions. Histopathologically, the glandular structure and type of the surrounding breast tissue were not significantly different between well-defined and ill-defined fibroadenomas. The stromal type of fibroadenoma was sclerotic in 8 (29%) well-defined fibroadenomas while sclerotic in 15 (72%) of 21 ill-defined fibroadenomas,showing difference with a statistical significance between well-defined and ill-defined fibroadenomas (p<0.05). Twenty (71%) of 28 fibroadenomas with well-defined sonographic margins showed well-defined border between mass and the surrounding breast tissue, pathologically. Meanwhile, twenty (95%) of 21 fibroadenomas with ill-defined sonographic margins demonstrated interdigitation of the surrounding breast tissue and mass, exhibiting a statistical significance (p<0.005). Ill-defined margins of fibroadenomas on sonography represent the interdigitation of the surrounding breast tissue with a mass and is seen in the sclerotic stromal type of fibroadenomas.

  9. Experimental and computational development of a natural breast phantom for dosimetry studies

    International Nuclear Information System (INIS)

    Nogueira, Luciana B.; Campos, Tarcisio P.R.

    2013-01-01

    This paper describes the experimental and computational development of a natural breast phantom, anthropomorphic and anthropometric for studies in dosimetry of brachytherapy and teletherapy of breast. The natural breast phantom developed corresponding to fibroadipose breasts of women aged 30 to 50 years, presenting radiographically medium density. The experimental breast phantom was constituted of three tissue-equivalents (TE's): glandular TE, adipose TE and skin TE. These TE's were developed according to chemical composition of human breast and present radiological response to exposure. Completed the construction of experimental breast phantom this was mounted on a thorax phantom previously developed by the research group NRI/UFMG. Then the computational breast phantom was constructed by performing a computed tomography (CT) by axial slices of the chest phantom. Through the images generated by CT a computational model of voxels of the thorax phantom was developed by SISCODES computational program, being the computational breast phantom represented by the same TE's of the experimental breast phantom. The images generated by CT allowed evaluating the radiological equivalence of the tissues. The breast phantom is being used in studies of experimental dosimetry both in brachytherapy as in teletherapy of breast. Dosimetry studies by MCNP-5 code using the computational model of the phantom breast are in progress. (author)

  10. CINtec PLUS immunocytochemistry as a tool for the cytologic diagnosis of glandular lesions of the cervix uteri.

    Science.gov (United States)

    Ravarino, Alberto; Nemolato, Sonia; Macciocu, Elena; Fraschini, Matteo; Senes, Giancarlo; Faa, Gavino; Negri, Giovanni

    2012-11-01

    Cytologic findings of glandular lesions of the cervix uteri are often difficult to evaluate. We studied the usefulness of CINtec PLUS p16/Ki-67 double stain (mtm laboratories, Heidelberg, Germany) for the diagnosis of glandular lesions. The study included 47 abnormal results on liquid-based cytologic tests with a subsequent histologic diagnosis of adenocarcinoma in situ or with early invasion, and 16 samples with negative results on follow-up. All samples were stained with CINtec PLUS p16/Ki-67 double stain. Of the neoplastic samples, 7 were excluded because of insufficient residual cellularity or loss of neoplastic cells. Of the samples that were adequate, 92.5% were stained with CINtec PLUS, whereas 7.5% were judged inconclusive. All inconclusive cases were at least 3 years old. Of the 16 negative samples, 15 (93.8%) stained negative and only 1 (6.2%) showed several positive clusters of cells. Our study shows that CINtec PLUS is a robust and useful tool for the diagnosis of glandular lesions of the cervix uteri.

  11. [Markers of stromal invasion during background and precancerous changes of the glandular epithelium and in adenocarcinoma of the cervix uteri].

    Science.gov (United States)

    Danilova, N V; Andreeva, Iu Iu; Zavalishina, L É; Mal'kov, P G

    2012-01-01

    It is very difficult to identify stromal invasion when the glandular epithelium of the cervix uteri is involved. It is necessary to draw a clear distinction between its glandular structures and adenocarcinoma in situ, involving the preexisting crypts and invasive glands. An attempt was made to assess the possibilities of using as markers of invasion the following stromal proteins and adhesion molecules: CD44, E-cadherin, beta-catenin, tenascin, and laminin. Fifty-three cases of benign glandular changes, 66 cases of dysplasias and adenocarcinomas in situ, and 47 cases of invasive adenocarcinoma were examined. An immunohistochemical study was performed according to the standard protocol using the antibodies to CD44, laminin, tenascin, E-cadherin, and beta-catenin and a semiquantitative assessment of results was made. CD44 was found to be redistributed from the cells to the tumor stroma. CD44 was not detected in the stroma surrounding the intact glands, so were benign epithelial changes. In the tumor environment, there was, on the contrary, a reaction with CD44 in 74.5% of invasive adenocarcinomas cases (p 0.05). CD44 and tenascin are of great diagnostic value in examining invasive and microinvasive adenocarcinomas of the cervix uteri. E-cadherin and beta-catenin are of no diagnostic value in the study groups of pathological processes. Laminin is a potential marker of stromal invasion; however, its expression calls for further investigation.

  12. Genetics and biochemistry of collagen binding-triggered glandular differentiation in a human colon carcinoma cell line

    International Nuclear Information System (INIS)

    Pignatelli, M.; Bodmer, W.F.

    1988-01-01

    The authors have examined the interaction between collagen binding and epithelial differentiation by using a human colon carcinoma cell line (SW1222) that can differentiate structurally when grown in a three-dimensional collagen gel to form glandular structures. As much as 66% inhibition of glandular differentiation can be achieved by addition to the culture of a synthetic peptide containing the Arg-Gly-Asp-Thr (RGDT) sequence, which is a cell recognition site found in collagen. Arg-Gly-Asp-Thr also inhibited the cell attachment to collagen-coated plates. Chromosome 15 was found in all human-mouse hybrid clones that could differentiate in the collagen gel and bind collagen. Both binding to collagen and glandular differentiation of the hybrid cells were also inhibited by Arg-Gly-Asp-Thr as for the parent cell line SW1222. The ability of SW1222 cells to express the differentiated phenotype appears, therefore, to be determined by an Arg-Gly-Asp-directed collagen receptor on the cell surface that is controlled by a gene on chromosome 15

  13. Quantification of breast density using dual-energy mammography with liquid phantom calibration

    International Nuclear Information System (INIS)

    Lam, Alfonso R; Ding, Huanjun; Molloi, Sabee

    2014-01-01

    Breast density is a widely recognized potential risk factor for breast cancer. However, accurate quantification of breast density is a challenging task in mammography. The current use of plastic breast-equivalent phantoms for calibration provides limited accuracy in dual-energy mammography due to the chemical composition of the phantom. We implemented a breast-equivalent liquid phantom for dual-energy calibration in order to improve the accuracy of breast density measurement. To design these phantoms, three liquid compounds were chosen: water, isopropyl alcohol, and glycerol. Chemical compositions of glandular and adipose tissues, obtained from NIST database, were used as reference materials. Dual-energy signal of the liquid phantom at different breast densities (0% to 100%) and thicknesses (1 to 8 cm) were simulated. Glandular and adipose tissue thicknesses were estimated from a higher order polynomial of the signals. Our results indicated that the linear attenuation coefficients of the breast-equivalent liquid phantoms match those of the target material. Comparison between measured and known breast density data shows a linear correlation with a slope close to 1 and a non-zero intercept of 7%, while plastic phantoms showed a slope of 0.6 and a non-zero intercept of 8%. Breast density results derived from the liquid calibration phantoms showed higher accuracy than those derived from the plastic phantoms for different breast thicknesses and various tube voltages. We performed experimental phantom studies using liquid phantoms and then compared the computed breast density with those obtained using a bovine tissue model. The experimental data and the known values were in good correlation with a slope close to 1 (∼1.1). In conclusion, our results indicate that liquid phantoms are a reliable alternative for calibration in dual-energy mammography and better reproduce the chemical properties of the target material. (paper)

  14. Relative Composition of Fibrous Connective and Fatty/Glandular Tissue in Connective Tissue Grafts Depends on the Harvesting Technique but not the Donor Site of the Hard Palate.

    Science.gov (United States)

    Bertl, Kristina; Pifl, Markus; Hirtler, Lena; Rendl, Barbara; Nürnberger, Sylvia; Stavropoulos, Andreas; Ulm, Christian

    2015-12-01

    Whether the composition of palatal connective tissue grafts (CTGs) varies depending on donor site or harvesting technique in terms of relative amounts of fibrous connective tissue (CT) and fatty/glandular tissue (FGT) is currently unknown and is histologically assessed in the present study. In 10 fresh human cadavers, tissue samples were harvested in the anterior and posterior palate and in areas close to (marginal) and distant from (apical) the mucosal margin. Mucosal thickness, lamina propria thickness (defined as the extent of subepithelial portion of the biopsy containing ≤25% or ≤50% FGT), and proportions of CT and FGT were semi-automatically estimated for the entire mucosa and for CTGs virtually harvested by split-flap (SF) preparation minimum 1 mm deep or after deepithelialization (DE). Palatal mucosal thickness, ranging from 2.35 to 6.89 mm, and histologic composition showed high interindividual variability. Lamina propria thickness (P >0.21) and proportions of CT (P = 0.48) and FGT (P = 0.15) did not differ significantly among the donor sites (anterior, posterior, marginal, apical). However, thicker palatal tissue was associated with higher FGT content (P tissue composition in the hard palate, DE-harvested CTG contains much larger amounts of CT and much lower amounts of FGT than SF-harvested CTG, irrespective of the harvesting site.

  15. Negative ion 'chip-based' nanospray tandem mass spectrometry for the analysis of flavonoids in glandular trichomes of Lychnophora ericoides Mart. (Asteraceae).

    Science.gov (United States)

    Gobbo-Neto, Leonardo; Gates, Paul J; Lopes, Norberto P

    2008-12-01

    This paper reports a method for the analysis of secondary metabolites stored in glandular trichomes, employing negative ion 'chip-based' nanospray tandem mass spectrometry. The analyses of glandular trichomes from Lychnophora ericoides, a plant endemic to the Brazilian 'cerrado' and used in traditional medicine as an anti-inflammatory and analgesic agent, led to the identification of five flavonoids (chrysin, pinocembrin, pinostrobin, pinobanksin and 3-O-acetylpinobanksin) by direct infusion of the extracts of glandular trichomes into the nanospray ionisation source. All the flavonoids have no oxidation at ring B, which resulted in a modification of the fragmentation pathways compared with that of the oxidised 3,4-dihydroflavonoids already described in the literature. The absence of the anti-inflammatory and antioxidant di-C-glucosylflavone vicenin-2, or any other flavonoid glycosides, in the glandular trichomes was also demonstrated. The use of the 'chip-based' nanospray QqTOF apparatus is a new fast and useful tool for the identification of secondary metabolites stored in the glandular trichomes, which can be useful for chemotaxonomic studies based on metabolites from glandular trichomes.

  16. Background parenchymal enhancement on breast MRI and mammographic breast density: correlation with tumour characteristics

    International Nuclear Information System (INIS)

    Kim, M.Y.; Choi, N.; Yang, J.-H.; Yoo, Y.B.; Park, K.S.

    2015-01-01

    Aim: To investigate the relationship between mammographic breast density (MGD) and background parenchymal enhancement (BPE) at breast MRI and histopathological features of invasive breast cancers. Materials and methods: A total of 178 women with unilateral invasive breast cancer who preoperatively underwent mammography and breast MRI were included in the study. Two radiologists rated MGD and BPE according to BI-RADS criteria in consensus. The relationship between MGD and BPE was investigated, and compared with histopathological features of invasive breast cancers according to the level of MGD and BPE. Results: At MRI, there is no significant difference in the distribution of MGD and BPE of the contralateral breast in women with invasive breast cancer according to menopausal status (p=0.226, 0.384). Women with high MGD (>50% glandular) were more likely to have oestrogen-receptor (ER)-positive breast cancer (p=0.045) and progesterone receptor (PR)-positive breast cancer (p=0.020). With regard to BPE, PR positivity correlated with moderate or marked BPE with borderline significance (p=0.054). Multivariate logistic regression analyses revealed that women with high MGD were less likely to have triple-negative (i.e., a cancer that is ER negative, PR negative, and human epidermal growth factor receptor type 2 [HER2] negative) breast cancer compared with ER (+)/HER2 (−) cancer (OR=0.231, 95% CI: 0.070, 0.760; p=0.016). No association between the histological tumour characteristics and BPE was observed. Conclusion: In women with invasive breast cancer, high MGD is associated with ER positivity of the invasive breast cancer. However, at MRI, BPE of the contralateral breast seems to be independent of tumour characteristics. -- Highlights: •There is no difference in distribution of MGD and BPE of contralateral breast on MRI. •High MGD is associated with ER positivity of the invasive breast cancer. •BPE of the contralateral breast on MRI is independent of tumor

  17. Breast Tomosynthesis

    Science.gov (United States)

    ... in distinguishing non-cancerous breast conditions from breast cancers. Breast implants may also impede accurate mammogram readings because both ... view as much as possible without rupturing the implant. top of ... discuss breast cancer screening options with their doctors: Breast Density and ...

  18. Radiology of the male breast. Radiologische Diagnostik der maennlichen Brustdruese. Mammographie, Sonographie, pathohistologische Korrelation

    Energy Technology Data Exchange (ETDEWEB)

    Buchberger, W; Penz, T; Strasser, K [Innsbruck Univ. (Austria). Universitaetsklinik fuer Radiodiagnostik; Toetsch, M [Innsbruck Univ. (Austria). Inst. fuer Pathologische Anatomie

    1991-09-01

    61 men with breast enlargement underwent mammography; complementary sonography was performed in 34 cases. Diagnoses included gynaecomastia in 53 cases, pseudogynaecomastia in 9 cases, 3 carcinomas, 2 inflammatory lesions and 1 lipoma. Mammography and sonography can differentiate reliably true gynaecomastia from pseudogynaecomastia. Gynaecomastia and especially inflammatory lesions may not always be readily differentiated from carcinoma. Sonography can be helpful by demonstrating hyperreflexive glandular tissue, whereas carcinomas are usually hypoechoic. (orig./GDG).

  19. Low-Dose Contrast-Enhanced Breast CT Using Spectral Shaping Filters: An Experimental Study.

    Science.gov (United States)

    Makeev, Andrey; Glick, Stephen J

    2017-12-01

    Iodinated contrast-enhanced X-ray imaging of the breast has been studied with various modalities, including full-field digital mammography (FFDM), digital breast tomosynthesis (DBT), and dedicated breast CT. Contrast imaging with breast CT has a number of advantages over FFDM and DBT, including the lack of breast compression, and generation of fully isotropic 3-D reconstructions. Nonetheless, for breast CT to be considered as a viable tool for routine clinical use, it would be desirable to reduce radiation dose. One approach for dose reduction in breast CT is spectral shaping using X-ray filters. In this paper, two high atomic number filter materials are studied, namely, gadolinium (Gd) and erbium (Er), and compared with Al and Cu filters currently used in breast CT systems. Task-based performance is assessed by imaging a cylindrical poly(methyl methacrylate) phantom with iodine inserts on a benchtop breast CT system that emulates clinical breast CT. To evaluate detectability, a channelized hoteling observer (CHO) is used with sums of Laguerre-Gauss channels. It was observed that spectral shaping using Er and Gd filters substantially increased the dose efficiency (defined as signal-to-noise ratio of the CHO divided by mean glandular dose) as compared with kilovolt peak and filter settings used in commercial and prototype breast CT systems. These experimental phantom study results are encouraging for reducing dose of breast CT, however, further evaluation involving patients is needed.

  20. Postmortem validation of breast density using dual-energy mammography

    Energy Technology Data Exchange (ETDEWEB)

    Molloi, Sabee, E-mail: symolloi@uci.edu; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A. [Department of Radiological Sciences, University of California, Irvine, California 92697 (United States)

    2014-08-15

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer.

  1. Postmortem validation of breast density using dual-energy mammography

    International Nuclear Information System (INIS)

    Molloi, Sabee; Ducote, Justin L.; Ding, Huanjun; Feig, Stephen A.

    2014-01-01

    Purpose: Mammographic density has been shown to be an indicator of breast cancer risk and also reduces the sensitivity of screening mammography. Currently, there is no accepted standard for measuring breast density. Dual energy mammography has been proposed as a technique for accurate measurement of breast density. The purpose of this study is to validate its accuracy in postmortem breasts and compare it with other existing techniques. Methods: Forty postmortem breasts were imaged using a dual energy mammography system. Glandular and adipose equivalent phantoms of uniform thickness were used to calibrate a dual energy basis decomposition algorithm. Dual energy decomposition was applied after scatter correction to calculate breast density. Breast density was also estimated using radiologist reader assessment, standard histogram thresholding and a fuzzy C-mean algorithm. Chemical analysis was used as the reference standard to assess the accuracy of different techniques to measure breast composition. Results: Breast density measurements using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean algorithm, and dual energy were in good agreement with the measured fibroglandular volume fraction using chemical analysis. The standard error estimates using radiologist reader assessment, standard histogram thresholding, fuzzy C-mean, and dual energy were 9.9%, 8.6%, 7.2%, and 4.7%, respectively. Conclusions: The results indicate that dual energy mammography can be used to accurately measure breast density. The variability in breast density estimation using dual energy mammography was lower than reader assessment rankings, standard histogram thresholding, and fuzzy C-mean algorithm. Improved quantification of breast density is expected to further enhance its utility as a risk factor for breast cancer

  2. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, Rosangela Requi; Messias, Pricila Cordeiro; Santos, Marilia Fernanda; Urban, Linei Augusta B.D.

    2014-01-01

    In Brazil breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Breast Digital Tomosynthesis (BDT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared to the mammography. This study presents results of Contrast Ratio Noise tests (CRN) and quality image on a Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CRN was determined with plates Polymethylmethacrylate (PMMA) of 20 to 70 mm thickness and an aluminum plate of 10 mm 2 and 0.2 mm thickness. Image quality was assessed with the ACR Breast Simulator. In assessment of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Were visualized 4.5 fibers and 4 mass in both modes. In 2D mode groups have been identified 3.5 microcalcifications, and 3D were 3 groups. The Mean Glandular Dose for the simulator in 2D mode was 1.17 mGy and 2.35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CRN values, ensuring image quality and dose compatible in 2D and 3D processes

  3. Quality control in breast tomosynthesis

    Energy Technology Data Exchange (ETDEWEB)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F., E-mail: requi@utfpr.edu.br [Universidade Tecnologia Federal do Parana (UTFPR), Curitiba, PR (Brazil). Departamento Academico de Fisica; Urban, L.A.B.D., E-mail: lineiurban@hotmail.com [Diagnostico Avancado por Imagem, Curitiba, PR (Brazil)

    2015-07-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  4. Quality control in breast tomosynthesis

    International Nuclear Information System (INIS)

    Jakubiak, R.R.; Messias, P.C.; Santos, M.F.

    2015-01-01

    In Brazil, breast cancer is the most common and the leading cause of death among women, with estimated 57,000 new cases in 2014. The mammography (2D) plays an important role in the early detection of breast cancer, but in some cases can be difficult to detect malignant lesions due overlap of breast tissues. The Digital Breasts Tomosynthesis (DBT: 3D) reduces the effects of overlap, providing improved characterization of mammographic findings. However, the dose may double as compared with mammography. This study presents results of Contrast to Noise Ratio (CNR) and image quality evaluation on Siemens mammography equipment Mammomat Inspiration with tomosynthesis. The CNR was determined with Polymethylmethacrylate (PMMA) layers of 20 to 70 mm thick and an aluminum foils of 0,2 mm thickness and area of 10 mm². Image quality was assessed with the ACR Breast Simulator. In the evaluation of image quality, the detectability of fibers and masses was identical in 2D and 3D systems. Displaying fibers were 4,5 and 4 mass in both modes. In 2D mode were identified 3,5 microcalcifications groups, and 3D showed 3 groups. The Mean Glandular Dose (MGD) for the simulator in 2D mode was 1,17 mGy and 2,35 mGy for the 3D mode. The result reinforces the importance of quality control in the process of obtaining the images and obtained in accordance CNR values, ensuring image quality and compatible dose in 2D and 3D processes. (author)

  5. Changes in ultrasound shear wave elastography properties of normal breast during menstrual cycle.

    Science.gov (United States)

    Rzymski, P; Skórzewska, A; Opala, T

    2011-01-01

    Elastography is a novel technique capable of noninvasively assessing the elastic properties of breast tissue. Because the risk factors for breast cancer include hormonal status and proliferation, the aim of our study was to estimate the intensity of sonoelastographic changes during the menstrual cycle. Eight women aged 20-23 years with regular menstrual cycles underwent B-mode sonography and sonoelastography (ShearWave on Aixplorer, France) on days 3, 10, 17 and 24. Mean values of glandular and fat tissue elasticity did not change statistically significantly during the menstrual cycle as well as glandular to fat tissue ratio. During almost the whole cycle differences between outer and inner quadrants in glandular and fat tissue were statistically significant. The lowest values of elasticity occurred on the 10th day and the highest on the 24th of the menstrual cycle. There were statistically significant differences in elasticity between inner and outer quadrants of both breasts close to day 3 and 17 of the menstrual cycle.

  6. TH-AB-209-11: Breast Microcalcification Classification Using Spectral X-Ray Coherent Scatter Computed Tomography

    Energy Technology Data Exchange (ETDEWEB)

    Ghammraoui, B; M Popescu, L; Badano, A [Food & Drug Administration, Silver Spring, MD (United States)

    2016-06-15

    Purpose: To investigate the ability of Coherent Scatter Computed Tomography (CSCT) to distinguish non-invasively between type I calcifications, consisting of calcium oxalate dihydrate (CO) compounds which are more often associated with benign lesions, and type II calcifications containing hydroxyapatite (HA) which are predominantly associated with malignant tumors. Methods: The coherent scatter cross sections of HA and CO were measured using an energy dispersive x-ray diffractometer. The measured cross sections were introduced into MC-GPU Monte Carlo simulation code for studying the applicability of CSCT to discriminate between the two types of microcalcifications within the whole breast. Simulations were performed on a virtual phantom with inserted HA and CO spots of different sizes and placed in regions of interest having different background compositions. We considered a polychromatic x-ray source and an energy resolving photon counting detector. We applied an algorithm that estimates scatter components in projection space in order to obtain material-specific images of the breast. As material components adipose, glandular, HA and CO were used. The relative contrast of HA and CO components were used for type I and type II microcalcification discrimination. Results: The reconstructed CSCT images showed material-specific component-contrast values, with the highest CO or HA component contrast corresponding generally to the actual CO or HA feature, respectively. The discrimination performance varies with the x-ray intensity, calcification size, and background composition. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to unity. Conclusion: The simulation results obtained for a uniform breast imaging phantom indicate that CSCT has potential to be used as a non-invasive method for discrimination between type

  7. Dynamic MRI of breast fibroadenoma: pathologic correlation

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Ki Keun; Hahm, Jin kyeung; Yoon, Pyong Ho; Jeong, Eun Kee [Yonsei University, College of Medicine, Seoul (Korea, Republic of)

    1995-09-15

    To analyze the dynamic MR imaging of breast fibroadenoma according to the histologic type for differentiation from breast carcinoma. Dynamic MR images of 26 lesions from 22 breasts in 19 patients showing atypical clinical features or film mammogram and ultrasound manifestations were performed. We analyzed the speed and the maximal amount of contrast enhancement and the patterns, such as shape, border, and internal signal intensity, among the histologic types during five minutes after contrast injection. The speed and maximal amount of contrast enhancement of fibroadenoma were in descending order of myxoid, sclerotic, glandular, and calcified types. Among these, the value of maximal amount of contrast enhancement of myxoid and sclerotic type were more than 700 NU, but only myxoid type was enhanced more than 700 NU within the first 1 minute after contrast injection, similar to the findings of carcinoma. In general, fibroadenoma showed the tendency of smooth surface(69%), well-defined border(88%) with safety rim, and internal homogeneous signal intensity(65%). However, sclerotic type of fibroadenoma had relatively high incidence of heterogeneous internal signal intensity(78%) after Gd-DTPA injection. Dynamic MR imaging of atypical breast fibroadenoma mimicking breast malignancy was very useful in differentiation it from carcinoma and had the benefit of classifying fibroadenoma according to its histologic types.

  8. Dynamic MRI of breast fibroadenoma: pathologic correlation

    International Nuclear Information System (INIS)

    Oh, Ki Keun; Hahm, Jin kyeung; Yoon, Pyong Ho; Jeong, Eun Kee

    1995-01-01

    To analyze the dynamic MR imaging of breast fibroadenoma according to the histologic type for differentiation from breast carcinoma. Dynamic MR images of 26 lesions from 22 breasts in 19 patients showing atypical clinical features or film mammogram and ultrasound manifestations were performed. We analyzed the speed and the maximal amount of contrast enhancement and the patterns, such as shape, border, and internal signal intensity, among the histologic types during five minutes after contrast injection. The speed and maximal amount of contrast enhancement of fibroadenoma were in descending order of myxoid, sclerotic, glandular, and calcified types. Among these, the value of maximal amount of contrast enhancement of myxoid and sclerotic type were more than 700 NU, but only myxoid type was enhanced more than 700 NU within the first 1 minute after contrast injection, similar to the findings of carcinoma. In general, fibroadenoma showed the tendency of smooth surface(69%), well-defined border(88%) with safety rim, and internal homogeneous signal intensity(65%). However, sclerotic type of fibroadenoma had relatively high incidence of heterogeneous internal signal intensity(78%) after Gd-DTPA injection. Dynamic MR imaging of atypical breast fibroadenoma mimicking breast malignancy was very useful in differentiation it from carcinoma and had the benefit of classifying fibroadenoma according to its histologic types

  9. Breast Metastases from Extramammary Malignancies: Typical and Atypical Ultrasound Features

    Energy Technology Data Exchange (ETDEWEB)

    Mun, Sung Hee [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of); Department of Radiology, Catholic University of Daegu College of Medicine, Daegu 712-702 (Korea, Republic of); Ko, Eun Young; Han, Boo-Kyung; Shin, Jung Hee [Department of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of); Kim, Suk Jung [Department of Radiology, Inje University College of Medicine, Busan Paik Hospital, Busan 614-735 (Korea, Republic of); Cho, Eun Yoon [Department of Pathology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul 135-710 (Korea, Republic of)

    2014-07-01

    Breast metastases from extramammary malignancies are uncommon. The most common sources are lymphomas/leukemias and melanomas. Some of the less common sources include carcinomas of the lung, ovary, and stomach, and infrequently, carcinoid tumors, hypernephromas, carcinomas of the liver, tonsil, pleura, pancreas, cervix, perineum, endometrium and bladder. Breast metastases from extramammary malignancies have both hematogenous and lymphatic routes. According to their routes, there are common radiological features of metastatic diseases of the breast, but the features are not specific for metastases. Typical ultrasound (US) features of hematogenous metastases include single or multiple, round to oval shaped, well-circumscribed hypoechoic masses without spiculations, calcifications, or architectural distortion; these masses are commonly located superficially in subcutaneous tissue or immediately adjacent to the breast parenchyma that is relatively rich in blood supply. Typical US features of lymphatic breast metastases include diffusely and heterogeneously increased echogenicities in subcutaneous fat and glandular tissue and a thick trabecular pattern with secondary skin thickening, lymphedema, and lymph node enlargement. However, lesions show variable US features in some cases, and differentiation of these lesions from primary breast cancer or from benign lesions is difficult. In this review, we demonstrate various US appearances of breast metastases from extramammary malignancies as typical and atypical features, based on the results of US and other imaging studies performed at our institution. Awareness of the typical and atypical imaging features of these lesions may be helpful to diagnose metastatic lesions of the breast.

  10. Breast Metastases from Extramammary Malignancies: Typical and Atypical Ultrasound Features

    International Nuclear Information System (INIS)

    Mun, Sung Hee; Ko, Eun Young; Han, Boo-Kyung; Shin, Jung Hee; Kim, Suk Jung; Cho, Eun Yoon

    2014-01-01

    Breast metastases from extramammary malignancies are uncommon. The most common sources are lymphomas/leukemias and melanomas. Some of the less common sources include carcinomas of the lung, ovary, and stomach, and infrequently, carcinoid tumors, hypernephromas, carcinomas of the liver, tonsil, pleura, pancreas, cervix, perineum, endometrium and bladder. Breast metastases from extramammary malignancies have both hematogenous and lymphatic routes. According to their routes, there are common radiological features of metastatic diseases of the breast, but the features are not specific for metastases. Typical ultrasound (US) features of hematogenous metastases include single or multiple, round to oval shaped, well-circumscribed hypoechoic masses without spiculations, calcifications, or architectural distortion; these masses are commonly located superficially in subcutaneous tissue or immediately adjacent to the breast parenchyma that is relatively rich in blood supply. Typical US features of lymphatic breast metastases include diffusely and heterogeneously increased echogenicities in subcutaneous fat and glandular tissue and a thick trabecular pattern with secondary skin thickening, lymphedema, and lymph node enlargement. However, lesions show variable US features in some cases, and differentiation of these lesions from primary breast cancer or from benign lesions is difficult. In this review, we demonstrate various US appearances of breast metastases from extramammary malignancies as typical and atypical features, based on the results of US and other imaging studies performed at our institution. Awareness of the typical and atypical imaging features of these lesions may be helpful to diagnose metastatic lesions of the breast

  11. Breast infection

    Science.gov (United States)

    Mastitis; Infection - breast tissue; Breast abscess ... must continue to breastfeed or pump to relieve breast swelling from milk production. In case if the abscess does not go away, needle aspiration under ultrasound ...

  12. Breast lump

    Science.gov (United States)

    ... with milk). These cysts can occur with breastfeeding. Breast abscess . These typically occur if you are breastfeeding or ... Breast infections are treated with antibiotics. Sometimes a breast abscess needs to be drained with a needle or ...

  13. Breast Diseases

    Science.gov (United States)

    ... bumps, and discharges (fluids that are not breast milk). If you have a breast lump, pain, discharge or skin irritation, see your health care provider. Minor and serious breast problems have similar ...

  14. Breast lift

    Science.gov (United States)

    ... and areola may be moved. Sometimes, women have breast augmentation (enlargement with implants) when they have a breast lift. Why the ... MD, FACS, general surgery practice specializing in breast cancer, Virginia Mason Medical Center, Seattle, WA. Also reviewed ...

  15. Breast cancer

    Science.gov (United States)

    ... can help you know how to prevent breast cancer. Breast implants, using antiperspirants, and wearing underwire bras do not increase the risk for breast cancer. There is also no evidence of a direct ...

  16. Fibroadenoma - breast

    Science.gov (United States)

    Breast lump - fibroadenoma; Breast lump - noncancerous; Breast lump - benign ... The cause of fibroadenomas is not known. They may be related to hormones. Girls who are going through puberty and women who are ...

  17. Benign breast disease, mammographic breast density, and the risk of breast cancer.

    Science.gov (United States)

    Tice, Jeffrey A; O'Meara, Ellen S; Weaver, Donald L; Vachon, Celine; Ballard-Barbash, Rachel; Kerlikowske, Karla

    2013-07-17

    Benign breast disease and high breast density are prevalent, strong risk factors for breast cancer. Women with both risk factors may be at very high risk. We included 42818 women participating in the Breast Cancer Surveillance Consortium who had no prior diagnosis of breast cancer and had undergone at least one benign breast biopsy and mammogram; 1359 women developed incident breast cancer in 6.1 years of follow-up (78.1% invasive, 21.9% ductal carcinoma in situ). We calculated hazard ratios (HRs) using Cox regression analysis. The referent group was women with nonproliferative changes and average density. All P values are two-sided. Benign breast disease and breast density were independently associated with breast cancer. The combination of atypical hyperplasia and very high density was uncommon (0.6% of biopsies) but was associated with the highest risk for breast cancer (HR = 5.34; 95% confidence interval [CI] = 3.52 to 8.09, P < .001). Proliferative disease without atypia (25.6% of biopsies) was associated with elevated risk that varied little across levels of density: average (HR = 1.37; 95% CI = 1.11 to 1.69, P = .003), high (HR = 2.02; 95% CI = 1.68 to 2.44, P < .001), or very high (HR = 2.05; 95% CI = 1.54 to 2.72, P < .001). Low breast density (4.5% of biopsies) was associated with low risk (HRs <1) for all benign pathology diagnoses. Women with high breast density and proliferative benign breast disease are at very high risk for future breast cancer. Women with low breast density are at low risk, regardless of their benign pathologic diagnosis.

  18. Experimental dosimetry in conformal breast teletherapy compared with the planning system

    International Nuclear Information System (INIS)

    Nogueira, Luciana Batista; Silva, Hugo Leonardo Lemos; Passos Ribeiro de Campos, Tarcísio

    2015-01-01

    The objective of this study was to compare and analyse the absorbed dose profiles from the conformal radiotherapy planning and experimental dosimetry taken in a breast anthropomorphic and anthropometric phantom. Conformal radiotherapy planning was elaborated in the Treatment Planning System (TPS). EBT2 Gafchromic radiochromic films were applied as dosimeters, positioned internally and superficially in the breast phantom. The standard radiation protocol was applied in the breast phantom. The films were digitalised, and their responses were analysed in RGB. The optical densities were processed, reproducing the spatial dose distribution. - Highlights: • Distributions of absorbed doses were generated by the TPS and measured by radiochromic films. • The breast phantom simulated a human breast in position for treatment. • A large portion of the glandular tissue absorbed doses that were equivalent to the radiotherapy planning. • There were regions of hot spots and small areas of under dosage in deeper areas at the lung interface

  19. Breast reconstruction - implants

    Science.gov (United States)

    Breast implants surgery; Mastectomy - breast reconstruction with implants; Breast cancer - breast reconstruction with implants ... harder to find a tumor if your breast cancer comes back. Getting breast implants does not take as long as breast reconstruction ...

  20. The evolving role of the breast physician in the multidisciplinary breast team.

    Science.gov (United States)

    Brennan, Meagan; Spillane, Andrew

    2007-10-01

    Breast physicians are medical practitioners trained in the diagnosis and management of breast disease. This relatively small group of specialized clinicians has a unique and expanding role in multidisciplinary breast teams in Australia and New Zealand. With minimal available published works, this article studies the varied roles that breast physicians carry out and the way they participate in the multidisciplinary team. Investigation of their current roles in breast medicine identified breast physicians providing a broad range of clinical care in public and private breast clinics and breast screening programmes as well as holding academic and administrative positions in clinical and non-clinical organizations. Numerous benefits for patients and for specialist breast clinicians working in partnership with breast physicians were identified. Breast surgeons are often the most advantaged by the contributions made by the breast physician to the multidisciplinary breast-care team with breast physicians particularly adding value to the service provided by breast surgeons. Breast physicians are well-trained, highly valuable members of the multidisciplinary breast team with a skill set that may enhance patient care at all stages from diagnosis to treatment to follow up.

  1. Effect of 935-MHz phone-simulating electromagnetic radiation on endometrial glandular cells during mouse embryo implantation.

    Science.gov (United States)

    Liu, Wenhui; Zheng, Xinmin; Qu, Zaiqing; Zhang, Ming; Zhou, Chun; Ma, Ling; Zhang, Yuanzhen

    2012-10-01

    This study examined the impact of 935MHz phone-simulating electromagnetic radiation on embryo implantation of pregnant mice. Each 7-week-old Kunming (KM) female white mouse was set up with a KM male mouse in a single cage for mating overnight after induction of ovulation. In the first three days of pregnancy, the pregnant mice was exposed to electromagnetic radiation at low-intensity (150 μW/cm(2), ranging from 130 to 200 μW/cm(2), for 2- or 4-h exposure every day), mid-intensity (570 μW/cm(2), ranging from 400 to 700 μW/cm(2), for 2- or 4-h exposure every day) or high-intensity (1400 μW/cm(2), ranging from 1200 to 1500 μW/cm(2), for 2- or 4-h exposure every day), respectively. On the day 4 after gestation (known as the window of murine embryo implantation), the endometrium was collected and the suspension of endometrial glandular cells was made. Laser scanning microscopy was employed to detect the mitochondrial membrane potential and intracellular calcium ion concentration. In high-intensity, 2- and 4-h groups, mitochondrial membrane potential of endometrial glandular cells was significantly lower than that in the normal control group (Pelectromagnetic radiation and longer length of the radiation are required to inflict a remarkable functional and structural damage to mitochondrial membrane. Our data demonstrated that electromagnetic radiation with a 935-MHz phone for 4 h conspicuously decreased mitochondrial membrane potential and lowered the calcium ion concentration of endometrial glandular cells. It is suggested that high-intensity electromagnetic radiation is very likely to induce the death of embryonic cells and decrease the chance of their implantation, thereby posing a high risk to pregnancy.

  2. The key role of peltate glandular trichomes in symbiota comprising clavicipitaceous fungi of the genus periglandula and their host plants.

    Science.gov (United States)

    Steiner, Ulrike; Kucht, Sabine Hellwig neé; Ahimsa-Müller, Mahalia A; Grundmann, Nicola; Li, Shu-Ming; Drewke, Christel; Leistner, Eckhard

    2015-04-16

    Clavicipitaceous fungi producing ergot alkaloids were recently discovered to be epibiotically associated with peltate glandular trichomes of Ipomoea asarifolia and Turbina corymbosa, dicotyledonous plants of the family Convolvulaceae. Mediators of the close association between fungi and trichomes may be sesquiterpenes, main components in the volatile oil of different convolvulaceous plants. Molecular biological studies and microscopic investigations led to the observation that the trichomes do not only secrete sesquiterpenes and palmitic acid but also seem to absorb ergot alkaloids from the epibiotic fungal species of the genus Periglandula. Thus, the trichomes are likely to have a dual and key function in a metabolic dialogue between fungus and host plant.

  3. Population of 224 realistic human subject-based computational breast phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Erickson, David W. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Wells, Jered R., E-mail: jered.wells@duke.edu [Clinical Imaging Physics Group and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Sturgeon, Gregory M. [Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 (United States); Samei, Ehsan [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics, Electrical and Computer Engineering, and Biomedical Engineering, and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Dobbins, James T. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Physics and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Segars, W. Paul [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States); Lo, Joseph Y. [Department of Radiology and Carl E. Ravin Advanced Imaging Laboratories, Duke University Medical Center, Durham, North Carolina 27705 and Departments of Electrical and Computer Engineering and Biomedical Engineering and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27705 (United States)

    2016-01-15

    Purpose: To create a database of highly realistic and anatomically variable 3D virtual breast phantoms based on dedicated breast computed tomography (bCT) data. Methods: A tissue classification and segmentation algorithm was used to create realistic and detailed 3D computational breast phantoms based on 230 + dedicated bCT datasets from normal human subjects. The breast volume was identified using a coarse three-class fuzzy C-means segmentation algorithm which accounted for and removed motion blur at the breast periphery. Noise in the bCT data was reduced through application of a postreconstruction 3D bilateral filter. A 3D adipose nonuniformity (bias field) correction was then applied followed by glandular segmentation using a 3D bias-corrected fuzzy C-means algorithm. Multiple tissue classes were defined including skin, adipose, and several fractional glandular densities. Following segmentation, a skin mask was produced which preserved the interdigitated skin, adipose, and glandular boundaries of the skin interior. Finally, surface modeling was used to produce digital phantoms with methods complementary to the XCAT suite of digital human phantoms. Results: After rejecting some datasets due to artifacts, 224 virtual breast phantoms were created which emulate the complex breast parenchyma of actual human subjects. The volume breast density (with skin) ranged from 5.5% to 66.3% with a mean value of 25.3% ± 13.2%. Breast volumes ranged from 25.0 to 2099.6 ml with a mean value of 716.3 ± 386.5 ml. Three breast phantoms were selected for imaging with digital compression (using finite element modeling) and simple ray-tracing, and the results show promise in their potential to produce realistic simulated mammograms. Conclusions: This work provides a new population of 224 breast phantoms based on in vivo bCT data for imaging research. Compared to previous studies based on only a few prototype cases, this dataset provides a rich source of new cases spanning a wide range

  4. Subcellular localization of YKL-40 in normal and malignant epithelial cells of the breast

    DEFF Research Database (Denmark)

    Roslind, A.; Balslev, E.; Kruse, H.

    2008-01-01

    . YKL-40 protein expression was redistributed in carcinoma versus normal glandular tissue of the breast. A reduced expression of YKL-40 in relation to intermediate filaments and desmosomes was found in tumor cells. Changes in YKL-40 expression suggest that the function of YKL-40 in cells of epithelial......YKL-40 is a new prognostic biomarker in cancer. The biological function is only poorly understood. This study aimed at determining the subcellular localization of YKL-40, using immunogold labeling, in normal epithelial cells and in malignant tumor cells of the breast by immunoelectron microscopy...

  5. Screening for breast cancer with mammography

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Jørgensen, Karsten Juhl

    2013-01-01

    A variety of estimates of the benefits and harms of mammographic screening for breast cancer have been published and national policies vary.......A variety of estimates of the benefits and harms of mammographic screening for breast cancer have been published and national policies vary....

  6. Hybrid phosphorescence and fluorescence native spectroscopy for breast cancer detection.

    Science.gov (United States)

    Alimova, Alexandra; Katz, A; Sriramoju, Vidyasagar; Budansky, Yuri; Bykov, Alexei A; Zeylikovich, Roman; Alfano, R R

    2007-01-01

    Fluorescence and phosphorescence measurements are performed on normal and malignant ex vivo human breast tissues using UV LED and xenon lamp excitation. Tryptophan (trp) phosphorescence intensity is higher in both normal glandular and adipose tissue when compared to malignant tissue. An algorithm based on the ratio of trp fluorescence intensity at 345 nm to phosphorescence intensity at 500 nm is successfully used to separate normal from malignant tissue types. Normal specimens consistently exhibited a low I(345)I(500) ratio (15). The ratio analysis correlates well with histopathology. Intensity ratio maps with a spatial resolution of 0.5 mm are generated in which local regions of malignancy could be identified.

  7. K5/K14-positive cells contribute to salivary gland-like breast tumors with myoepithelial differentiation

    DEFF Research Database (Denmark)

    Boecker, Werner; Stenman, Goeran; Loening, Thomas

    2013-01-01

    different cell lineages and define their cellular hierarchy in tumors with myoepithelial differentiation. isTILT analysis of a series of 28 breast, salivary, and lacrimal gland tumors, including pleomorphic adenomas (n=8), epithelial-myoepithelial tumors (n=9), and adenoid cystic carcinomas (n=11) revealed...... heterologeous cell differentiations such as squamous and mesenchymal progenies. p63 was co-expressed with K5/K14 in basal-like progenitor cells, myoepithelial, and squamous cells but not in glandular cells. Our results show that the corresponding counterpart tumors of breast and salivary/lacrimal glands have....... For that reason, we performed an in situ triple immunofluorescence lineage/differentiation tracing (isTILT) and qRT-PCR study of basal (K5/K14), glandular (K7/K8/18), and epidermal-specific squamous (K10) keratins, p63, and smooth muscle actin (SMA; myoepithelial marker) with the aim to construct and trace...

  8. Cancer of the accessory breast - a case report

    International Nuclear Information System (INIS)

    Madej, B.; Balak, B.; Winkler, I.; Burdan, F.

    2009-01-01

    Breast neoplasm may develop in ectopically located glandular tissue. This paper presents an interesting and rare case of a 50-year-old female who despite regular mammography screening examination developed an invasive accessory breast cancer. Clinical examination revealed a 2 cm - tumour localized 4 cm below the left infra mammary fold. The lesion was immobile, the skin and the atrophic nipple were retracted, the tumour infiltrated the thoracic wall. Oligo biopsy and additional examinations showed an invasive stage IIIB ductal breast cancer (Bloom II, G-2). The receptor status was: ER(+), PGR(+), HER2(-). The increased level of cancer antigen 15.3 was found. The patient was submitted to pre-operative chemotherapy. She also underwent surgery and subsequently post-operative chemotherapy and radiotherapy. On the basis of the presented case, it could be concluded that the accessory mammary glands are out of the image of screening breast examinations. Accessory breast cancer is usually diagnosed by clinical examination and ultrasonography. Preventive resection of accessory breast in women at high risk of developing breast cancer can be considered as the treatment of choice in most patients. (authors)

  9. Trans-nipple removal of fibro-glandular tissue in gynaecomastia surgery without additional scars: An innovative approach

    Directory of Open Access Journals (Sweden)

    R K Mishra

    2014-01-01

    Full Text Available Context: The established techniques that have been used to treat gynaecomastia are said to have relatively less patient satisfaction rate as they leave some visible scars or mild elevation over the nipple areola complex, resulting in aesthetically unsatisfactory results. Even the slightest elevation or smallest scar over nipple areola complex leave patients extremely self conscious and in a dilemma of having a second intervention to get rid of that blemish. Aims: The aim of the study is to achieve - A flat chest without adding a scar and with no chances of re-occurrence of the condition. This article suggests an innovative approach to address the problem. Materials and Methods: The author presents trans-nipple incision approach for the delivery of fibro-glandular tissue component following liposuction for maximum patient satisfaction. This method consists of a unique small criss-cross incision right on the nipple itself for retrieving any volume of tough fibro-glandular tissues. Between the duration of January 2012 to October 2013, 28 male patients of different ages were operated with this technique. Results: The surgery resulted in well-shaped, symmetric chest contour without any visible elevation or additional scars on nipple areola complex. No complications were noticed in any of the patients. Conclusions: The presented technique is proved to have a high patient satisfaction rate and to be promising method to achieve good aesthetic results in gynaecomastia surgery.

  10. Time-varying BRDFs.

    Science.gov (United States)

    Sun, Bo; Sunkavalli, Kalyan; Ramamoorthi, Ravi; Belhumeur, Peter N; Nayar, Shree K

    2007-01-01

    The properties of virtually all real-world materials change with time, causing their bidirectional reflectance distribution functions (BRDFs) to be time varying. However, none of the existing BRDF models and databases take time variation into consideration; they represent the appearance of a material at a single time instance. In this paper, we address the acquisition, analysis, modeling, and rendering of a wide range of time-varying BRDFs (TVBRDFs). We have developed an acquisition system that is capable of sampling a material's BRDF at multiple time instances, with each time sample acquired within 36 sec. We have used this acquisition system to measure the BRDFs of a wide range of time-varying phenomena, which include the drying of various types of paints (watercolor, spray, and oil), the drying of wet rough surfaces (cement, plaster, and fabrics), the accumulation of dusts (household and joint compound) on surfaces, and the melting of materials (chocolate). Analytic BRDF functions are fit to these measurements and the model parameters' variations with time are analyzed. Each category exhibits interesting and sometimes nonintuitive parameter trends. These parameter trends are then used to develop analytic TVBRDF models. The analytic TVBRDF models enable us to apply effects such as paint drying and dust accumulation to arbitrary surfaces and novel materials.

  11. In vivo breast sound-speed imaging with ultrasound tomography

    Energy Technology Data Exchange (ETDEWEB)

    Huang, Lianjie [Los Alamos National Laboratory; Li, Cuiping [KARMANOS CANCER INSTITUTE; Duric, Neb [KARMANOS CANCER INSTITUTE; Littrup, Peter [KARMONOS CANCER INSTITUTE

    2009-01-01

    We discuss a bent-ray ultrasound tomography algorithm with total-variation (TV) regularization. We have applied this algorithm to 61 in vivo breast datasets collected with our in-house clinical prototype for imaging sound-speed distributions in the breast. Our analysis showed that TV regularization could preserve sharper lesion edges than the classic Tikhonov regularization. Furthermore, the image quality of our TV bent-ray sound-speed tomograms was superior to that of the straight-ray counterparts for all types of breasts within BI-RADS density categories 1-4. For all four breast types from fatty to dense, the improvements for average sharpness (in the unit of (m{center_dot} s) {sup -1}) of lesion edges in our TV bent-ray tomograms are between 2.1 to 3.4 fold compared to the straight ray tomograms. Reconstructed sound-speed tomograms illustrated that our algorithm could successfully image fatty and glandular tissues within the breast. We calculated the mean sound-speed values for fatty tissue and breast parenchyma as 1422 {+-} 9 mls (mean{+-} SD) and1487 {+-} 21 mls, respectively. Based on 32 lesions in a cohort of 61 patients, we also found that the mean sound-speed for malignant breast lesions (1548{+-}17 mls) was higher, on average, than that of benign ones (1513{+-}27 mls) (one-sided pbreast density (, and therefore, breast cancer risk), as well as detect and help differentiate breast lesions. Finally, our sound-speed tomograms may also be a useful tool to monitor clinical response of breast cancer patients to neo-adjuvant chemotherapy.

  12. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries

    Energy Technology Data Exchange (ETDEWEB)

    Lazebnik, Mariya [Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI (United States); Popovic, Dijana [Department of Electrical and Computer Engineering, University of Calgary, Calgary, AB (Canada); McCartney, Leah [Department of Electrical and Computer Engineering, University of Calgary, Calgary, AB (Canada); Watkins, Cynthia B [Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI (United States); Lindstrom, Mary J [Department of Biostatistics and Medical Informatics, University of Wisconsin, Madison, WI (United States); Harter, Josephine [Department of Pathology, University of Wisconsin, Madison, WI (United States); Sewall, Sarah [Department of Pathology, University of Wisconsin, Madison, WI (United States); Ogilvie, Travis [Department of Pathology, University of Calgary, Calgary, AB (Canada); Magliocco, Anthony [Department of Pathology, University of Calgary, Calgary, AB (Canada); Breslin, Tara M [Department of Surgery, University of Wisconsin, Madison, WI (United States); Temple, Walley [Department of Surgery and Oncology, University of Calgary, Calgary, AB (Canada); Mew, Daphne [Department of Surgery and Oncology, University of Calgary, Calgary, AB (Canada); Booske, John H [Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI (United States); Okoniewski, Michal [Department of Electrical and Computer Engineering, University of Calgary, Calgary, AB (Canada); Hagness, Susan C [Department of Electrical and Computer Engineering, University of Wisconsin, Madison, WI (United States)

    2007-10-21

    The development of microwave breast cancer detection and treatment techniques has been driven by reports of substantial contrast in the dielectric properties of malignant and normal breast tissues. However, definitive knowledge of the dielectric properties of normal and diseased breast tissues at microwave frequencies has been limited by gaps and discrepancies across previously published studies. To address these issues, we conducted a large-scale study to experimentally determine the ultrawideband microwave dielectric properties of a variety of normal, malignant and benign breast tissues, measured from 0.5 to 20 GHz using a precision open-ended coaxial probe. Previously, we reported the dielectric properties of normal breast tissue samples obtained from reduction surgeries. Here, we report the dielectric properties of normal (adipose, glandular and fibroconnective), malignant (invasive and non-invasive ductal and lobular carcinomas) and benign (fibroadenomas and cysts) breast tissue samples obtained from cancer surgeries. We fit a one-pole Cole-Cole model to the complex permittivity data set of each characterized sample. Our analyses show that the contrast in the microwave-frequency dielectric properties between malignant and normal adipose-dominated tissues in the breast is considerable, as large as 10:1, while the contrast in the microwave-frequency dielectric properties between malignant and normal glandular/fibroconnective tissues in the breast is no more than about 10%.

  13. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries

    Science.gov (United States)

    Lazebnik, Mariya; Popovic, Dijana; McCartney, Leah; Watkins, Cynthia B.; Lindstrom, Mary J.; Harter, Josephine; Sewall, Sarah; Ogilvie, Travis; Magliocco, Anthony; Breslin, Tara M.; Temple, Walley; Mew, Daphne; Booske, John H.; Okoniewski, Michal; Hagness, Susan C.

    2007-10-01

    The development of microwave breast cancer detection and treatment techniques has been driven by reports of substantial contrast in the dielectric properties of malignant and normal breast tissues. However, definitive knowledge of the dielectric properties of normal and diseased breast tissues at microwave frequencies has been limited by gaps and discrepancies across previously published studies. To address these issues, we conducted a large-scale study to experimentally determine the ultrawideband microwave dielectric properties of a variety of normal, malignant and benign breast tissues, measured from 0.5 to 20 GHz using a precision open-ended coaxial probe. Previously, we reported the dielectric properties of normal breast tissue samples obtained from reduction surgeries. Here, we report the dielectric properties of normal (adipose, glandular and fibroconnective), malignant (invasive and non-invasive ductal and lobular carcinomas) and benign (fibroadenomas and cysts) breast tissue samples obtained from cancer surgeries. We fit a one-pole Cole-Cole model to the complex permittivity data set of each characterized sample. Our analyses show that the contrast in the microwave-frequency dielectric properties between malignant and normal adipose-dominated tissues in the breast is considerable, as large as 10:1, while the contrast in the microwave-frequency dielectric properties between malignant and normal glandular/fibroconnective tissues in the breast is no more than about 10%.

  14. A large-scale study of the ultrawideband microwave dielectric properties of normal, benign and malignant breast tissues obtained from cancer surgeries

    International Nuclear Information System (INIS)

    Lazebnik, Mariya; Popovic, Dijana; McCartney, Leah; Watkins, Cynthia B; Lindstrom, Mary J; Harter, Josephine; Sewall, Sarah; Ogilvie, Travis; Magliocco, Anthony; Breslin, Tara M; Temple, Walley; Mew, Daphne; Booske, John H; Okoniewski, Michal; Hagness, Susan C

    2007-01-01

    The development of microwave breast cancer detection and treatment techniques has been driven by reports of substantial contrast in the dielectric properties of malignant and normal breast tissues. However, definitive knowledge of the dielectric properties of normal and diseased breast tissues at microwave frequencies has been limited by gaps and discrepancies across previously published studies. To address these issues, we conducted a large-scale study to experimentally determine the ultrawideband microwave dielectric properties of a variety of normal, malignant and benign breast tissues, measured from 0.5 to 20 GHz using a precision open-ended coaxial probe. Previously, we reported the dielectric properties of normal breast tissue samples obtained from reduction surgeries. Here, we report the dielectric properties of normal (adipose, glandular and fibroconnective), malignant (invasive and non-invasive ductal and lobular carcinomas) and benign (fibroadenomas and cysts) breast tissue samples obtained from cancer surgeries. We fit a one-pole Cole-Cole model to the complex permittivity data set of each characterized sample. Our analyses show that the contrast in the microwave-frequency dielectric properties between malignant and normal adipose-dominated tissues in the breast is considerable, as large as 10:1, while the contrast in the microwave-frequency dielectric properties between malignant and normal glandular/fibroconnective tissues in the breast is no more than about 10%

  15. Classification of breast microcalcifications using spectral mammography

    Science.gov (United States)

    Ghammraoui, B.; Glick, S. J.

    2017-03-01

    Purpose: To investigate the potential of spectral mammography to distinguish between type I calcifications, consisting of calcium oxalate dihydrate or weddellite compounds that are more often associated with benign lesions, and type II calcifications containing hydroxyapatite which are predominantly associated with malignant tumors. Methods: Using a ray tracing algorithm, we simulated the total number of x-ray photons recorded by the detector at one pixel from a single pencil-beam projection through a breast of 50/50 (adipose/glandular) tissues with inserted microcalcifications of different types and sizes. Material decomposition using two energy bins was then applied to characterize the simulated calcifications into hydroxyapatite and weddellite using maximumlikelihood estimation, taking into account the polychromatic source, the detector response function and the energy dependent attenuation. Results: Simulation tests were carried out for different doses and calcification sizes for multiple realizations. The results were summarized using receiver operating characteristic (ROC) analysis with the area under the curve (AUC) taken as an overall indicator of discrimination performance and showing high AUC values up to 0.99. Conclusion: Our simulation results obtained for a uniform breast imaging phantom indicate that spectral mammography using two energy bins has the potential to be used as a non-invasive method for discrimination between type I and type II microcalcifications to improve early breast cancer diagnosis and reduce the number of unnecessary breast biopsies.

  16. Differences in breast tissue oxygenation following radiotherapy

    International Nuclear Information System (INIS)

    Dornfeld, Ken; Gessert, Charles E.; Renier, Colleen M.; McNaney, David D.; Urias, Rodolfo E.; Knowles, Denise M.; Beauduy, Jean L.; Widell, Sherry L.; McDonald, Bonita L.

    2011-01-01

    Tissue perfusion and oxygenation changes following radiotherapy may result from and/or contribute to the toxicity of treatment. Breast tissue oxygenation levels were determined in the treated and non-treated breast 1 year after radiotherapy for breast conserving treatment. Transcutaneous oxygenation varied between subjects in both treated and non-treated breast. Subjects without diabetes mellitus (n = 16) had an average oxygenation level of 64.8 ± 19.9 mmHg in the irradiated breast and an average of 72.3 ± 18.1 mmHg (p = 0.018) at the corresponding location in the control breast. Patients with diabetes (n = 4) showed a different oxygenation pattern, with lower oxygenation levels in control tissue and no decrease in the irradiated breast. This study suggests oxygenation levels in normal tissues vary between patients and may respond differently after radiotherapy.

  17. A new test phantom with different breast tissue compositions for image quality assessment in conventional and digital mammography

    International Nuclear Information System (INIS)

    Pachoud, Marc; Lepori, D; Valley, Jean-Francois; Verdun, Francis R

    2004-01-01

    Our objective is to describe a new test phantom that permits the objective assessment of image quality in conventional and digital mammography for different types of breast tissue. A test phantom, designed to represent a compressed breast, was made from tissue equivalent materials. Three separate regions, with different breast tissue compositions, are used to evaluate low and high contrast resolution, spatial resolution and image noise. The phantom was imaged over a range of kV using a Contour 2000 (Bennett) mammography unit with a Kodak MinR 2190-MinR L screen-film combination and a Senograph 2000D (General Electric) digital mammography unit. Objective image quality assessments for different breast tissue compositions were performed using the phantom for conventional and digital mammography. For a similar mean glandular dose (MGD), the digital system gives a significantly higher contrast-to-noise ratio (CNR) than the screen-film system for 100% glandular tissue. In conclusion, in mammography, a range of exposure conditions is used for imaging because of the different breast tissue compositions encountered clinically. Ideally, the patient dose-image quality relationship should be optimized over the range of exposure conditions. The test phantom presented in this work permits image quality parameters to be evaluated objectively for three different types of breast tissue. Thus, it is a useful tool for optimizing the patient dose-image quality relationship

  18. Monte Carlo simulations to assess the effects of tube current modulation on breast dose for multidetector CT

    International Nuclear Information System (INIS)

    Angel, Erin; Yaghmai, Nazanin; Jude, Cecilia Matilda; DeMarco, John J; Cagnon, Christopher H; Goldin, Jonathan G; McNitt-Gray, Michael F; Primak, Andrew N; McCollough, Cynthia H; Stevens, Donna M; Cody, Dianna D

    2009-01-01

    Tube current modulation was designed to reduce radiation dose in CT imaging while maintaining overall image quality. This study aims to develop a method for evaluating the effects of tube current modulation (TCM) on organ dose in CT exams of actual patient anatomy. This method was validated by simulating a TCM and a fixed tube current chest CT exam on 30 voxelized patient models and estimating the radiation dose to each patient's glandular breast tissue. This new method for estimating organ dose was compared with other conventional estimates of dose reduction. Thirty detailed voxelized models of patient anatomy were created based on image data from female patients who had previously undergone clinically indicated CT scans including the chest area. As an indicator of patient size, the perimeter of the patient was measured on the image containing at least one nipple using a semi-automated technique. The breasts were contoured on each image set by a radiologist and glandular tissue was semi-automatically segmented from this region. Previously validated Monte Carlo models of two multidetector CT scanners were used, taking into account details about the source spectra, filtration, collimation and geometry of the scanner. TCM data were obtained from each patient's clinical scan and factored into the model to simulate the effects of TCM. For each patient model, two exams were simulated: a fixed tube current chest CT and a tube current modulated chest CT. X-ray photons were transported through the anatomy of the voxelized patient models, and radiation dose was tallied in the glandular breast tissue. The resulting doses from the tube current modulated simulations were compared to the results obtained from simulations performed using a fixed mA value. The average radiation dose to the glandular breast tissue from a fixed tube current scan across all patient models was 19 mGy. The average reduction in breast dose using the tube current modulated scan was 17%. Results were

  19. Metaplastic carcinoma of the breast: multimodality imaging and histopathologic assessment

    International Nuclear Information System (INIS)

    Choi, Bo Bae; Shu, Kwang Sun

    2012-01-01

    Background Metaplastic carcinomas are ductal carcinomas that display metaplastic transformation of the glandular epithelium to non-glandular mesenchymal tissue. Metaplastic carcinoma has a poorer prognosis than most other breast cancers, so the differential diagnosis is important. Although many clinical and pathologic findings have been reported, to our knowledge, few imaging findings related to metaplastic carcinoma have been reported. Purpose To investigate whole-breast imaging findings, including mammography, sonography, MRI, and pathologic findings, including immunohistochemical studies of metaplastic carcinomas of the breast. Material and Methods We analyzed 33 cases of metaplastic carcinoma between January 2001 and January 2011. Mammography, ultrasonography, and MRI were recorded retrospectively using the American College of Radiology (ACR) breast imaging reporting and data system (BI-RADS) lexicon. Immunohistochemical studies of estrogen receptor (ER), progesterone receptor (PR), p53, and C-erbB-2 were performed. Results The most common mammographic findings were oval shape (37%), circumscribed margin (59%), and high density (74%). The most common sonogfindings were irregular shape (59.4%), microlobulated margin (41%), complex echogenicity (81%), parallel orientation (97%), and posterior acoustic enhancement (50%). Axillary lymph node metastases were noted for 25% of the sonographic examinations. On MRI, the most common findings of margin and shape were irregularity (57% and 52.4%, respectively). High signal intensity was the most common finding on T2-weighted images (57%). Immunohistochemical profile was negative for ER (91%, 29/32) and PR (81%, 26/32). Conclusion Metaplastic carcinomas might display more benign features and less axillary lymph node metastasis than IDC. High signal intensity on T2 MRI images and hormone receptor negativity would be helpful in differentiating this tumor from other breast cancers

  20. Automation and Preclinical Evaluation of a Dedicated Emission Mammotomography System for Fully 3-D Molecular Breast Imaging

    National Research Council Canada - National Science Library

    Cutler, Spencer J

    2007-01-01

    .... A retrospective study of 103 clinical MRI uncompressed breast scans was conducted to create surface renderings of the uncompressed breasts and analyze how to adapt existing acquisition orbits for varying breast shapes...

  1. False positive reaction due to endogenous biotin activity in glandular epithelium of decidua Reação falso positiva em epitélio glandular da decídua devido a atividade endógena de biotina

    Directory of Open Access Journals (Sweden)

    Liliana Cruz Spano

    2005-06-01

    Full Text Available Biotin-labeled probe was used in an in situ hybridisation assay to localize virus infection in formalin-fixed, paraffin embedded tissues taken from eleven abortion cases. Probes for human cytomegalovirus (HCMV, human Parvovirus B19 (B19 and human adenovirus type 2 (HAd2, were labeled with biotin-11-dUTP by nick-translation reaction. Streptavidin-alkaline-phosphatase (SAP was used to detect biotin, followed by 4-nitroblue tetrazolium/5-bromo-4-chloro-3-indolyl phosphate (NBT/BCIP solution. Positive reaction was observed in nucleus of glandular ephitelium cells of decidua either in positive or in negative control at first and second gestational trimester. The reaction was not inhibited with blocking solution for alkaline phosphatase endogenous activity and it persisted even with probes omission. The use of adequate negative control permitted to reveal the presence of nuclear biotin in glandular epithelium of decidua, responsible for false positivity in detection systems involving streptavidin biotin system (StrepABC. The stained cells resembled to cytophatic effect due to herpesvirus, which could induce further misinterpretation. The results obtained in this study strongly recommend that DNA detection by in situ hybridisation reaction in gestational endometrium should be done without using StrepABC system.Sondas marcadas com biotina foram utilizadas neste trabalho para detecção de infecção viral por hibridização in situ em tecidos fixados com formalina e embebidos em parafina de 11 casos obtidos de abortamento. Sondas para citomegalovírus humano (HCMV, parvovírus B19 humano (B19 e adenovírus humano tipo 2 (HAd2, foram marcadas com biotina-11-dUTP através da reação de nick-translation. Estreptavidina conjugada com fosfatase alcalina (SAP seguida por solução de 4-nitro-azul de tetrazolio/5-bromo-4-cloro-3-indolil fosfato (NBT/BCIP foram utilizadas para detecção da biotina após a reação de hibridização. Reação positiva foi

  2. Comportamento da dose glandular versus contraste do objeto em mamografia: determinação de formalismo semi-empírico para diferentes combinações alvo-filtro Behavior of subject contrast versus glandular dose in mammography: determination of a semi-empirical formalism for different target-filter combinations

    Directory of Open Access Journals (Sweden)

    Gabriela Hoff

    2006-06-01

    Full Text Available OBJETIVO: Verificar o efeito da mudança no contraste do objeto, tempo de exposição e dose de radiação quando diferentes espessuras de filtração de molibdênio (Mo e ródio (Rh são empregadas em mamógrafos. MATERIAIS E MÉTODOS: Realizaram-se medidas da exposição na entrada da pele com uma câmara de ionização para diferentes espessuras para os filtros de Mo e Rh. Para determinar a dose glandular média foi utilizado simulador de BR12 (50% tecido adiposo e 50% tecido glandular de diferentes espessuras (4 cm e 8 cm. Energias na faixa de 24 kVp a 34 kVp foram empregadas e filmes Kodak MinR 2000 foram utilizados. RESULTADOS: Os resultados evidenciaram dados de contraste do objeto, dose glandular e tempo de exposição para diferentes espessuras de filtros adicionais e diferentes tensões. Esses dados indicaram aumento nos valores de contraste do objeto e tempo de exposição, com o aumento da espessura dos filtros. A dose glandular apresentou comportamento com diferentes tendências para cada caso analisado. Equações foram definidas para possibilitar a estimativa do contraste do objeto, dose glandular e tempo de exposição para os casos estudados. CONCLUSÃO: Os resultados possibilitaram a estimativa de equações que auxiliam na verificação do comportamento do contraste do objeto e da dose glandular para simuladores com espessura de 4 cm e 8 cm e para os filtros de Rh e Mo. Dessa forma, torna-se possível estimar a figura de mérito (razão entre o contraste do objeto e a dose glandular, podendo auxiliar na análise da relação risco-benefício dos casos estudados.OBJECTIVE: Our purpose was to verify the effect of changes in subject contrast, exposure time and radiation dose when different thicknesses of molybdenum (Mo and rhodium (Rh filters are used in mammography equipments. MATERIALS AND METHODS: Entrance skin exposure measurements were performed with an ionization chamber for different thicknesses of Mo and Rh filters

  3. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O'Connell, Avice M; Conover, David L

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of MGD to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9 ± 4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4 ± 6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum–minimum) of MGD from dedicated breast CT was lower than

  4. A comparison of methods to evaluate gray scale response of tomosynthesis systems using a software breast phantom

    Science.gov (United States)

    Sousa, Maria A. Z.; Bakic, Predrag R.; Schiabel, Homero; Maidment, Andrew D. A.

    2017-03-01

    Digital breast tomosynthesis (DBT) has been shown to be an effective imaging tool for breast cancer diagnosis as it provides three-dimensional images of the breast with minimal tissue overlap. The quality of the reconstructed image depends on many factors that can be assessed using uniform or realistic phantoms. In this paper, we created four models of phantoms using an anthropomorphic software breast phantom and compared four methods to evaluate the gray scale response in terms of the contrast, noise and detectability of adipose and glandular tissues binarized according to phantom ground truth. For each method, circular regions of interest (ROIs) were selected with various sizes, quantity and positions inside a square area in the phantom. We also estimated the percent density of the simulated breast and the capability of distinguishing both tissues by receiver operating characteristic (ROC) analysis. Results shows a sensitivity of the methods to the ROI size, placement and to the slices considered.

  5. Salivary gland acinar cells regenerate functional glandular structures in modified hydrogels

    Science.gov (United States)

    Pradhan, Swati

    Xerostomia, a condition resulting from irradiation of the head and neck, affects over 40,000 cancer patients each year in the United States. Direct radiation damage of the acinar cells that secrete fluid and protein results in salivary gland hypofunction. Present medical management for xerostomia for patients treated for upper respiratory cancer is largely ineffective. Patients who have survived their terminal diagnosis are often left with a diminished quality of life and are unable to enjoy the simple pleasures of eating and drinking. This project aims to ultimately reduce human suffering by developing a functional implantable artificial salivary gland. The goal was to create an extracellular matrix (ECM) modified hyaluronic acid (HA) based hydrogel culture system that allows for the growth and differentiation of salivary acinar cells into functional acini-like structures capable of secreting large amounts of protein and fluid unidirectionally and to ultimately engineer a functional artificial salivary gland that can be implanted into an animal model. A tissue collection protocol was established and salivary gland tissue was obtained from patients undergoing head and neck surgery. The tissue specimen was assessed by histology and immunohistochemistry to establish the phenotype of normal salivary gland cells including the native basement membranes. Hematoxylin and eosin staining confirmed normal glandular tissue structures including intercalated ducts, striated ducts and acini. alpha-Amylase and periodic acid schiff stain, used for structures with a high proportion of carbohydrate macromolecules, preferentially stained acinar cells in the tissue. Intercalated and striated duct structures were identified using cytokeratins 19 and 7 staining. Myoepithelial cells positive for cytokeratin 14 were found wrapped around the serous and mucous acini. Tight junction components including ZO-1 and E-cadherin were present between both ductal and acinar cells. Ductal and acinar

  6. Breast Gangrene

    Directory of Open Access Journals (Sweden)

    Husasin Irfan

    2011-08-01

    Full Text Available Abstract Background Breast gangrene is rare in surgical practice. Gangrene of breast can be idiopathic or secondary to some causative factor. Antibiotics and debridement are used for management. Acute inflammatory infiltrate, severe necrosis of breast tissue, necrotizing arteritis, and venous thrombosis is observed on histopathology. The aim of was to study patients who had breast gangrene. Methods A prospective study of 10 patients who had breast gangrene over a period of 6 years were analyzed Results All the patients in the study group were female. Total of 10 patients were encountered who had breast gangrene. Six patients presented with breast gangrene on the right breast whereas four had on left breast. Out of 10 patients, three had breast abscess after teeth bite followed by gangrene, one had iatrogenic trauma by needle aspiration of erythematous area of breast under septic conditions. Four had history of application of belladonna on cutaneous breast abscess and had then gangrene. All were lactating female. Amongst the rest two were elderly, one of which was a diabetic who had gangrene of breast and had no application of belladonna. All except one had debridement under cover of broad spectrum antibiotics. Three patients had grafting to cover the raw area. Conclusion Breast gangrene occurs rarely. Etiology is variable and mutifactorial. Teeth bite while lactation and the iatrogenic trauma by needle aspiration of breast abscess under unsterlised conditions could be causative. Uncontrolled diabetes can be one more causative factor for the breast gangrene. Belladonna application as a topical agent could be inciting factor. Sometimes gangrene of breast can be idiopathic. Treatment is antibiotics and debridement.

  7. Phantom breast syndrome

    Directory of Open Access Journals (Sweden)

    Ramesh

    2009-01-01

    Full Text Available Phantom breast syndrome is a type of condition in which patients have a sensation of residual breast tissue and can include both non-painful sensations as well as phantom breast pain. The incidence varies in different studies, ranging from approximately 30% to as high as 80% of patients after mastectomy. It seriously affects quality of life through the combined impact of physical disability and emotional distress. The breast cancer incidence rate in India as well as Western countries has risen in recent years while survival rates have improved; this has effectively increased the number of women for whom post-treatment quality of life is important. In this context, chronic pain following treatment for breast cancer surgery is a significantly under-recognized and under-treated problem. Various types of chronic neuropathic pain may arise following breast cancer surgery due to surgical trauma. The cause of these syndromes is damage to various nerves during surgery. There are a number of assumed factors causing or perpetuating persistent neuropathic pain after breast cancer surgery. Most well-established risk factors for developing phantom breast pain and other related neuropathic pain syndromes are severe acute postoperative pain and greater postoperative use of analgesics. Based upon current evidence, the goals of prophylactic strategies could first target optimal peri-operative pain control and minimizing damage to nerves during surgery. There is some evidence that chronic pain and sensory abnormalities do decrease over time. The main group of oral medications studied includes anti-depressants, anticonvulsants, opioids, N-methyl-D-asparate receptor antagonists, mexilitine, topical lidocaine, cannabinoids, topical capsaicin and glysine antagonists. Neuromodulation techniques such as motor cortex stimulation, spinal cord stimulation, and intrathecal drug therapies have been used to treat various neuropathic pain syndromes.

  8. Breast Exam

    Science.gov (United States)

    ... ends. What you can expect Begin with a visual examination of your breasts Sit or stand shirtless ... to the next section. If you have a disability that makes it difficult to examine your breasts ...

  9. Breast cancer

    African Journals Online (AJOL)

    A collaborative article gives an overview of breast cancer in LICs, ... approach to the problem; therefore they are published as two separate ... attached to the diagnosis of breast cancer. ... Their founding statement in its early form is included.

  10. An audit of cervicovaginal cytology in a teaching hospital: Are atypical glandular cells under-recognised on cytological screening?

    Directory of Open Access Journals (Sweden)

    Crasta Julian

    2009-01-01

    Full Text Available Background: Cervical cytology screening for carcinoma of the cervix in India is mainly opportunistic in nature and is practiced mainly in urban centres. The effectiveness of cervical cytology screening depends on various factors. The quality of cervicovaginal cytology service is assessed by various quality indices and by cyto-histology correlation, which is the most important quality assurance measure. Aims: To describe the cervical cytology diagnoses, estimate the quality indices, and evaluate the discrepant cases on cytohistological correlation. Settings and Design: Retrospective observational study from a tertiary care centre in South India. Materials and Methods: Using a database search, all the cervicovaginal cytology reported during the period of 2002-2006 was retrieved and various diagnoses were described. The data was analysed to assess the quality indices. The cytohistologically discrepant cases were reviewed. Results: A total of 10,787 cases were retrieved, of which 98.14% were labeled negative and 1.36% were unsatisfactory for evaluation. A few (0.81% of the cases were labeled as squamous intraepithelial lesions and 0.38% as atypical squamous cells. The ASCUS: SIL ratio was 0.5. Cytohistological correlation revealed a total of ten cases with significant discrepancy. The majority of these were carcinomas that were misdiagnosed as atypical glandular cells. These cytology smears and the subsequent biopsies were reviewed to elucidate the reasons for the discrepancies. Conclusions: The cervical cytology service at our centre is well within the accepted standards. An increased awareness of cytological features, especially of glandular lesions, a good clinician-laboratory communication and a regular cytohistological review would further improve the diagnostic standards.

  11. An audit of cervicovaginal cytology in a teaching hospital: Are atypical glandular cells under-recognised on cytological screening?

    Science.gov (United States)

    Crasta, Julian A; Chaitra, V; Simi, Cm; Correa, Marjorie

    2009-04-01

    Cervical cytology screening for carcinoma of the cervix in India is mainly opportunistic in nature and is practiced mainly in urban centres. The effectiveness of cervical cytology screening depends on various factors. The quality of cervicovaginal cytology service is assessed by various quality indices and by cyto-histology correlation, which is the most important quality assurance measure. To describe the cervical cytology diagnoses, estimate the quality indices, and evaluate the discrepant cases on cytohistological correlation. Retrospective observational study from a tertiary care centre in South India. Using a database search, all the cervicovaginal cytology reported during the period of 2002-2006 was retrieved and various diagnoses were described. The data was analysed to assess the quality indices. The cytohistologically discrepant cases were reviewed. A total of 10,787 cases were retrieved, of which 98.14% were labeled negative and 1.36% were unsatisfactory for evaluation. A few (0.81%) of the cases were labeled as squamous intraepithelial lesions and 0.38% as atypical squamous cells. The ASCUS: SIL ratio was 0.5. Cytohistological correlation revealed a total of ten cases with significant discrepancy. The majority of these were carcinomas that were misdiagnosed as atypical glandular cells. These cytology smears and the subsequent biopsies were reviewed to elucidate the reasons for the discrepancies. The cervical cytology service at our centre is well within the accepted standards. An increased awareness of cytological features, especially of glandular lesions, a good clinician-laboratory communication and a regular cytohistological review would further improve the diagnostic standards.

  12. Breast Cancer

    Science.gov (United States)

    Breast cancer affects one in eight women during their lives. No one knows why some women get breast cancer, but there are many risk factors. Risks that ... who have family members with breast or ovarian cancer may wish to be tested for the genes. ...

  13. varying elastic parameters distributions

    KAUST Repository

    Moussawi, Ali

    2014-12-01

    The experimental identication of mechanical properties is crucial in mechanics for understanding material behavior and for the development of numerical models. Classical identi cation procedures employ standard shaped specimens, assume that the mechanical elds in the object are homogeneous, and recover global properties. Thus, multiple tests are required for full characterization of a heterogeneous object, leading to a time consuming and costly process. The development of non-contact, full- eld measurement techniques from which complex kinematic elds can be recorded has opened the door to a new way of thinking. From the identi cation point of view, suitable methods can be used to process these complex kinematic elds in order to recover multiple spatially varying parameters through one test or a few tests. The requirement is the development of identi cation techniques that can process these complex experimental data. This thesis introduces a novel identi cation technique called the constitutive compatibility method. The key idea is to de ne stresses as compatible with the observed kinematic eld through the chosen class of constitutive equation, making possible the uncoupling of the identi cation of stress from the identi cation of the material parameters. This uncoupling leads to parametrized solutions in cases where 5 the solution is non-unique (due to unknown traction boundary conditions) as demonstrated on 2D numerical examples. First the theory is outlined and the method is demonstrated in 2D applications. Second, the method is implemented within a domain decomposition framework in order to reduce the cost for processing very large problems. Finally, it is extended to 3D numerical examples. Promising results are shown for 2D and 3D problems.

  14. A parameterization method and application in breast tomosynthesis dosimetry

    Energy Technology Data Exchange (ETDEWEB)

    Li, Xinhua; Zhang, Da; Liu, Bob [Division of Diagnostic Imaging Physics and Webster Center for Advanced Research and Education in Radiation, Department of Radiology, Massachusetts General Hospital, Boston, Massachusetts 02114 (United States)

    2013-09-15

    Purpose: To present a parameterization method based on singular value decomposition (SVD), and to provide analytical parameterization of the mean glandular dose (MGD) conversion factors from eight references for evaluating breast tomosynthesis dose in the Mammography Quality Standards Act (MQSA) protocol and in the UK, European, and IAEA dosimetry protocols.Methods: MGD conversion factor is usually listed in lookup tables for the factors such as beam quality, breast thickness, breast glandularity, and projection angle. The authors analyzed multiple sets of MGD conversion factors from the Hologic Selenia Dimensions quality control manual and seven previous papers. Each data set was parameterized using a one- to three-dimensional polynomial function of 2–16 terms. Variable substitution was used to improve accuracy. A least-squares fit was conducted using the SVD.Results: The differences between the originally tabulated MGD conversion factors and the results computed using the parameterization algorithms were (a) 0.08%–0.18% on average and 1.31% maximum for the Selenia Dimensions quality control manual, (b) 0.09%–0.66% on average and 2.97% maximum for the published data by Dance et al. [Phys. Med. Biol. 35, 1211–1219 (1990); ibid. 45, 3225–3240 (2000); ibid. 54, 4361–4372 (2009); ibid. 56, 453–471 (2011)], (c) 0.74%–0.99% on average and 3.94% maximum for the published data by Sechopoulos et al. [Med. Phys. 34, 221–232 (2007); J. Appl. Clin. Med. Phys. 9, 161–171 (2008)], and (d) 0.66%–1.33% on average and 2.72% maximum for the published data by Feng and Sechopoulos [Radiology 263, 35–42 (2012)], excluding one sample in (d) that does not follow the trends in the published data table.Conclusions: A flexible parameterization method is presented in this paper, and was applied to breast tomosynthesis dosimetry. The resultant data offer easy and accurate computations of MGD conversion factors for evaluating mean glandular breast dose in the MQSA

  15. Breast tissue classification in digital tomosynthesis images based on global gradient minimization and texture features

    Science.gov (United States)

    Qin, Xulei; Lu, Guolan; Sechopoulos, Ioannis; Fei, Baowei

    2014-03-01

    Digital breast tomosynthesis (DBT) is a pseudo-three-dimensional x-ray imaging modality proposed to decrease the effect of tissue superposition present in mammography, potentially resulting in an increase in clinical performance for the detection and diagnosis of breast cancer. Tissue classification in DBT images can be useful in risk assessment, computer-aided detection and radiation dosimetry, among other aspects. However, classifying breast tissue in DBT is a challenging problem because DBT images include complicated structures, image noise, and out-of-plane artifacts due to limited angular tomographic sampling. In this project, we propose an automatic method to classify fatty and glandular tissue in DBT images. First, the DBT images are pre-processed to enhance the tissue structures and to decrease image noise and artifacts. Second, a global smooth filter based on L0 gradient minimization is applied to eliminate detailed structures and enhance large-scale ones. Third, the similar structure regions are extracted and labeled by fuzzy C-means (FCM) classification. At the same time, the texture features are also calculated. Finally, each region is classified into different tissue types based on both intensity and texture features. The proposed method is validated using five patient DBT images using manual segmentation as the gold standard. The Dice scores and the confusion matrix are utilized to evaluate the classified results. The evaluation results demonstrated the feasibility of the proposed method for classifying breast glandular and fat tissue on DBT images.

  16. Rayleigh to Compton ratio scatter tomography applied to breast cancer diagnosis: A preliminary computational study

    International Nuclear Information System (INIS)

    Antoniassi, M.; Conceição, A.L.C.; Poletti, M.E.

    2014-01-01

    In the present work, a tomographic technique based on Rayleigh to Compton scattering ratio (R/C) was studied using computational simulation in order to assess its application to breast cancer diagnosis. In this preliminary study, some parameters that affect the image quality were evaluated, such as: (i) energy beam, (ii) size and glandularity of the breast, and (iii) statistical count noise. The results showed that the R/C contrast increases with increasing photon energy and decreases with increasing glandularity of the sample. The statistical noise showed to be a significant parameter, although the quality of the obtained images was acceptable for a considerable range of noise level. The preliminary results suggest that the R/C tomographic technique has a potential of being applied as a complementary tool in the breast cancer diagnostic. - Highlights: ► A tomographic technique based on Rayleigh to Compton scattering ratio is proposed in order to study breast tissues. ► The Rayleigh to Compton scattering ratio technique is compared with conventional transmission technique. ► The influence of experimental parameters (energy, sample, detection system) is studied

  17. Breast reconstruction following mastectomy: current status in Australia.

    Science.gov (United States)

    Sandelin, Kerstin; King, Elizabeth; Redman, Sally

    2003-09-01

    Although breast reconstruction provides some advantages for women following mastectomy, few Australian breast cancer patients currently receive reconstruction. In Australia, the routine provision of breast reconstruction will require the development of specific health service delivery models. The present paper reports an analysis of the provision of breast reconstruction in eight sites in Australia. A semi-structured telephone interview was conducted with 10 surgeons offering breast reconstruction as part of their practice, including nine breast or general surgeons and one plastic surgeon. Surgeons reported offering breast reconstruction to all women facing mastectomy; the proportion of women deciding to have breast reconstruction varied between sites with up to 50% of women having a reconstruction at some sites. Most sites offered three types of reconstruction. Two pathways emerged: either the breast surgeon performed the breast surgery in a team with the plastic surgeon who undertook the breast reconstruction or the breast surgeon provided both the breast surgery and the reconstruction. Considerable waiting times for breast reconstruction were reported in the public sector particularly for delayed reconstruction. Surgeons reported receiving training in breast reconstruction from plastic surgeons or from a breast surgery team that performed reconstructions; a number had been trained overseas. No audits of breast reconstruction were being undertaken. Breast reconstruction can be offered on a routine basis in Australia in both the private and public sectors. Women may be more readily able to access breast reconstruction when it is provided by a breast surgeon alone, but the range of reconstruction options may be more limited. If access to breast reconstruction is to be increased, there will be a need to: (i) develop effective models for the rural sector taking account of the lack of plastic surgeons; (ii) address waiting times for reconstruction surgery in the

  18. Metastatic Urothelial Carcinoma with Glandular Differentiation That Confirmed the Response by Autopsy Specimen to Second-Line mFOLFOX6 (Fluorouracil, Oxaliplatin, and Leucovorin plus Bevacizumab Chemotherapy

    Directory of Open Access Journals (Sweden)

    Taku Naiki

    2017-11-01

    Full Text Available The prognostic significance of glandular differentiation in urothelial carcinoma (UC is controversial, and thus far there is no established treatment strategy against metastasis of glandular component. We describe here a case of metastatic UC with glandular differentiation that had histological disappearance of adenocarcinoma components at autopsy after sequential chemotherapy with S-1 and cisplatin (CDDP and with mFOLFOX6 (fluorouracil, oxaliplatin, and leucovorin plus bevacizumab (mFOLFOX6+Bev. A 62-year-old Asian male was diagnosed with invasive UC with glandular differentiation (T2N0M0 by radical cystectomy and ileal conduit, and careful follow-up observation was made. Eight years after radical operation, peritoneal metastases occurred, and a biopsy specimen using colon fiber revealed high-grade adenocarcinomas with an immunohistochemical profile that included positivity for cytokeratin 7 (CK7 and negativity for cytokeratin 20 (CK20 and uroplakin, which was identical to the radical cystectomy specimen. Thus, he received combination chemotherapy consisting of S-1 and CDDP; however, the peritoneal metastasis worsened after 2 cycles. Therefore, second-line mFOLFOX6+Bev chemotherapy was performed for a total of 5 courses. In spite of this, the patient died, and the final diagnosis by autopsy was multiple metastases of infiltrating pure UC to the lung, bone, and peritoneum. Interestingly, there were no pathological findings of adenocarcinoma, and the immunohistochemical profile of the metastatic lesions was identical to that of the previous specimens from the bladder and colon. This suggests that sequential chemotherapy of S-1 and CDDP and second-line mFOLFOX6+Bev might be a feasible option in metastatic UC with glandular differentiation.

  19. SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

    Energy Technology Data Exchange (ETDEWEB)

    Morris, R [Durham, NC (United States); Lakshmanan, M; Fong, G; Kapadia, A [Carl E Ravin Advanced Imaging Laboratories, Durham, NC (United States); Greenberg, J [Duke University, Durham, NC (United States)

    2016-06-15

    Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to

  20. Breast milk: immunosurveillance in infancy

    Directory of Open Access Journals (Sweden)

    Rachita Nanda

    2014-09-01

    Full Text Available Human breast milk is unique and a natural source of nutrition. However, it also helps to protect against various types of disease, not only infective but also immunological diseases. The wide variety of molecules in milk is responsible for its varied role for the newborn infant. Various breast milk proteins, contribute for its immunological, nutritional as well as its antimicrobial role. The naive immune system, intestinal mucosa and other organs of the neonate are also developed by various cellular factors. Breast milk protects not only during the neonatal period but also beyond it. By educating the neonatal immune system it also protects against the development of diseases later in life.

  1. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    International Nuclear Information System (INIS)

    Kiarashi, Nooshin; Nolte, Adam C.; Sturgeon, Gregory M.; Ghate, Sujata V.; Segars, William P.; Nolte, Loren W.; Samei, Ehsan

    2015-01-01

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  2. Development of realistic physical breast phantoms matched to virtual breast phantoms based on human subject data

    Energy Technology Data Exchange (ETDEWEB)

    Kiarashi, Nooshin [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Nolte, Adam C. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Sturgeon, Gregory M.; Ghate, Sujata V. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Segars, William P. [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 and Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Nolte, Loren W. [Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 and Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Samei, Ehsan [Carl E. Ravin Advanced Imaging Laboratories, Department of Radiology, Duke University Medical Center, Durham, North Carolina 27710 (United States); Department of Electrical and Computer Engineering, Duke University, Durham, North Carolina 27708 (United States); Department of Biomedical Engineering, Duke University, Durham, North Carolina 27708 (United States); Medical Physics Graduate Program, Duke University, Durham, North Carolina 27708 (United States); Department of Physics, Duke University, Durham, North Carolina 27708 (United States); and others

    2015-07-15

    Purpose: Physical phantoms are essential for the development, optimization, and evaluation of x-ray breast imaging systems. Recognizing the major effect of anatomy on image quality and clinical performance, such phantoms should ideally reflect the three-dimensional structure of the human breast. Currently, there is no commercially available three-dimensional physical breast phantom that is anthropomorphic. The authors present the development of a new suite of physical breast phantoms based on human data. Methods: The phantoms were designed to match the extended cardiac-torso virtual breast phantoms that were based on dedicated breast computed tomography images of human subjects. The phantoms were fabricated by high-resolution multimaterial additive manufacturing (3D printing) technology. The glandular equivalency of the photopolymer materials was measured relative to breast tissue-equivalent plastic materials. Based on the current state-of-the-art in the technology and available materials, two variations were fabricated. The first was a dual-material phantom, the Doublet. Fibroglandular tissue and skin were represented by the most radiographically dense material available; adipose tissue was represented by the least radiographically dense material. The second variation, the Singlet, was fabricated with a single material to represent fibroglandular tissue and skin. It was subsequently filled with adipose-equivalent materials including oil, beeswax, and permanent urethane-based polymer. Simulated microcalcification clusters were further included in the phantoms via crushed eggshells. The phantoms were imaged and characterized visually and quantitatively. Results: The mammographic projections and tomosynthesis reconstructed images of the fabricated phantoms yielded realistic breast background. The mammograms of the phantoms demonstrated close correlation with simulated mammographic projection images of the corresponding virtual phantoms. Furthermore, power

  3. Evaluation of the population dose to the UK population from the National Health Service breast screening programme

    International Nuclear Information System (INIS)

    Faulkner, K.; Wallis, M. G.; Neilson, F.; Whitaker, C. J.

    2008-01-01

    In the United Kingdom National Health Service Breast Screening Programme (NHSBSP), women aged between 50 and 70 y are invited for mammography every 3 y. Screening histories for each woman, over four screening rounds, were analysed. Data from five screening programmes were used to select 57 425 women into the study. Cases were selected on the basis of being between the ages of 50 and 53 at the start of the NHSBSP (i.e. between 1989 and 1992). Assessment of the outcome for each screening round for each woman involved assigning a simple outcome code. Each of the possible pathways through the four screening rounds was analysed. This comprises of 500 possible pathways. This data enabled the following information to be determined: (i) The number of times a woman attended the screening programme. (ii) The number of women referred for assessment at each screening round. This information may be used to deduce the population dose to this group of women averaged over four screening rounds. Patient doses have been monitored since the programme's inception and are typically 4.5 mGy for two-view screening. It is possible to determine the mean glandular dose received by this cohort of women over four screening rounds by multiplying the number of examinations by the mean glandular dose for a typical woman. Allowance has to be made for the number of projections taken at each screening round. Once a woman has been screened, she may be invited back for further assessment if an abnormality is found on her mammogram. A stereotactic attachment is used to determine where to place the biopsy device. Although the dose received during a normal screening mammogram is well known, the dose for a stereotactic procedure and other assessment procedures is less well known, partly because only a small part of the breast is directly irradiated during stereo-taxis. However, the woman may have multiple exposures during this stage. A prospective survey of doses was completed to deduce the mean

  4. Classification of fibroglandular tissue distribution in the breast based on radiotherapy planning CT

    International Nuclear Information System (INIS)

    Juneja, Prabhjot; Evans, Philip; Windridge, David; Harris, Emma

    2016-01-01

    Accurate segmentation of breast tissues is required for a number of applications such as model based deformable registration in breast radiotherapy. The accuracy of breast tissue segmentation is affected by the spatial distribution (or pattern) of fibroglandular tissue (FT). The goal of this study was to develop and evaluate texture features, determined from planning computed tomography (CT) data, to classify the spatial distribution of FT in the breast. Planning CT data of 23 patients were evaluated in this study. Texture features were derived from the radial glandular fraction (RGF), which described the distribution of FT within three breast regions (posterior, middle, and anterior). Using visual assessment, experts grouped patients according to FT spatial distribution: sparse or non-sparse. Differences in the features between the two groups were investigated using the Wilcoxon rank test. Classification performance of the features was evaluated for a range of support vector machine (SVM) classifiers. Experts found eight patients and 15 patients had sparse and non-sparse spatial distribution of FT, respectively. A large proportion of features (>9 of 13) from the individual breast regions had significant differences (p <0.05) between the sparse and non-sparse group. The features from middle region had most significant differences and gave the highest classification accuracy for all the SVM kernels investigated. Overall, the features from middle breast region achieved highest accuracy (91 %) with the linear SVM kernel. This study found that features based on radial glandular fraction provide a means for discriminating between fibroglandular tissue distributions and could achieve a classification accuracy of 91 %

  5. Breast Reconstruction After Mastectomy

    Science.gov (United States)

    ... Cancer Prevention Genetics of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Reconstruction After Mastectomy On This Page What is breast reconstruction? How do surgeons use implants to reconstruct a woman’s breast? How do surgeons ...

  6. Breast cancer screening

    Science.gov (United States)

    Mammogram - breast cancer screening; Breast exam - breast cancer screening; MRI - breast cancer screening ... is performed to screen women to detect early breast cancer when it is more likely to be cured. ...

  7. Stages of Breast Cancer

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  8. Breast Cancer Prevention

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Prevention (PDQ®)–Patient Version What is prevention? Go ... from starting. Risk-reducing surgery . General Information About Breast Cancer Key Points Breast cancer is a disease in ...

  9. Breast Cancer Treatment

    Science.gov (United States)

    ... of Breast & Gynecologic Cancers Breast Cancer Screening Research Breast Cancer Treatment (PDQ®)–Patient Version General Information About Breast Cancer Go to Health Professional Version Key Points Breast ...

  10. Metastatic Colonic Adenocarcinoma in Breast: Report of Two Cases and Review of the Literature

    Directory of Open Access Journals (Sweden)

    Jiten P. Kothadia

    2015-01-01

    Full Text Available Metastatic adenocarcinoma to the breast from an extramammary site is extremely rare. In the literature, the most current estimate is that extramammary metastases account for only 0.43% of all breast malignancies and that, of these extramammary sites, colon cancer metastases form a very small subset. Most commonly seen metastasis in breast is from a contralateral breast carcinoma, followed by metastasis from hematopoietic neoplasms, malignant melanoma, sarcoma, lung, prostate, and ovary and gastric neoplasms. Here we present two rare cases, in which colonic adenocarcinomas were found to metastasize to the breast. In both cases, core biopsies were obtained from the suspicious areas identified on mammogram. Histopathology revealed neoplastic proliferation of atypical glandular components within benign breast parenchyma which were morphologically consistent with metastatic adenocarcinoma. By immunohistochemical staining, it was confirmed that the neoplastic components were immunoreactive to colonic markers and nonreactive to breast markers, thus further supporting the morphologic findings. It is extremely important to make this distinction between primary breast cancer and a metastatic process, in order to provide the most effective and appropriate treatment for the patient and to avoid any harmful or unnecessary surgical procedures.

  11. Breast cancer

    OpenAIRE

    Gablerová, Pavlína

    2010-01-01

    In this work the topic of breast cancer treated more generally and mainly focused on risk factors for the development. The theoretical part describes the general knowledge about breast cancer as a stage or treatment. The practical part is to have clarified the risk factors that have some bearing on the diagnosis of breast cancer. What level are involved in the probability of occurrence? Can we eliminate them? As a comparison of risk factors examined in the Czech Republic, England, Australia a...

  12. Monoterpenes in the glandular trichomes of tomato are synthesized from a neryl diphosphate precursor rather than geranyl diphosphate.

    Science.gov (United States)

    Schilmiller, Anthony L; Schauvinhold, Ines; Larson, Matthew; Xu, Richard; Charbonneau, Amanda L; Schmidt, Adam; Wilkerson, Curtis; Last, Robert L; Pichersky, Eran

    2009-06-30

    We identified a cis-prenyltransferase gene, neryl diphosphate synthase 1 (NDPS1), that is expressed in cultivated tomato (Solanum lycopersicum) cultivar M82 type VI glandular trichomes and encodes an enzyme that catalyzes the formation of neryl diphosphate from isopentenyl diphosphate and dimethylallyl diphosphate. mRNA for a terpene synthase gene, phellandrene synthase 1 (PHS1), was also identified in these glands. It encodes an enzyme that uses neryl diphosphate to produce beta-phellandrene as the major product as well as a variety of other monoterpenes. The profile of monoterpenes produced by PHS1 is identical with the monoterpenes found in type VI glands. PHS1 and NDPS1 map to chromosome 8, and the presence of a segment of chromosome 8 derived from Solanum pennellii LA0716 causes conversion from the M82 gland monoterpene pattern to that characteristic of LA0716 plants. The data indicate that, contrary to the textbook view of geranyl diphosphate as the "universal" substrate of monoterpene synthases, in tomato glands neryl diphosphate serves as a precursor for the synthesis of monoterpenes.

  13. Identification and characterization of two bisabolene synthases from linear glandular trichomes of sunflower (Helianthus annuus L., Asteraceae).

    Science.gov (United States)

    Aschenbrenner, Anna-Katharina; Kwon, Moonhyuk; Conrad, Jürgen; Ro, Dae-Kyun; Spring, Otmar

    2016-04-01

    Sunflower is known to produce a variety of bisabolene-type sesquiterpenes and accumulates these substances in trichomes of leaves, stems and flowering parts. A bioinformatics approach was used to identify the enzyme responsible for the initial step in the biosynthesis of these compounds from its precursor farnesyl pyrophosphate. Based on sequence similarity with a known bisabolene synthases from Arabidopsis thaliana AtTPS12, candidate genes of Helianthus were searched in EST-database and used to design specific primers. PCR experiments identified two candidates in the RNA pool of linear glandular trichomes of sunflower. Their sequences contained the typical motifs of sesquiterpene synthases and their expression in yeast functionally characterized them as bisabolene synthases. Spectroscopic analysis identified the stereochemistry of the product of both enzymes as (Z)-γ-bisabolene. The origin of the two sunflower bisabolene synthase genes from the transcripts of linear trichomes indicates that they may be involved in the synthesis of sesquiterpenes produced in these trichomes. Comparison of the amino acid sequences of the sunflower bisabolene synthases showed high similarity with sesquiterpene synthases from other Asteracean species and indicated putative evolutionary origin from a β-farnesene synthase. Copyright © 2016 Elsevier Ltd. All rights reserved.

  14. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    Energy Technology Data Exchange (ETDEWEB)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A. [Federal University of Minas Gerais, Program of Nuclear Science and Techniques, Av. Pte. Antonio Carlos 6627, 31270-901 Belo Horizonte, Minas Gerais (Brazil)

    2015-10-15

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  15. Calculation of the average radiological detriment of two samples from a breast screening programme

    International Nuclear Information System (INIS)

    Ramos, M.; Sanchez, A.M.; Verdu, G.; Villaescusa, J.I.; Salas, M.D.; Cuevas, M.D.

    2002-01-01

    In 1992 started in the Comunidad Valenciana the Breast Cancer Screening Programme. The programme is oriented to asymptomatic women between 45 and 65 years old, with two mammograms in each breast for the first time that participate and a simple one in later interventions. Between November of 2000 and March of 2001 was extracted a first sample of 100 woman records for all units of the programme. The data extracted in each sample were the kV-voltage, the X-ray tube load and the breast thickness and age of the woman exposed, used directly in dose and detriment calculation. By means of MCNP-4B code and according to the European Protocol for the quality control of the physical and technical aspects of mammography screening, the average total and glandular doses were calculated, and later compared

  16. Evaluation of bismuth shielding effectiveness in reducing breast absorbed dose during thoracic CT scan

    International Nuclear Information System (INIS)

    Alonso, T. C.; Mourao, A. P.; Santana, P. C.; Silva, T. A.

    2015-10-01

    Computed Tomography (CT) is an essential method for tracking neoplasia and efficiently diagnosing a wide variety of thoracic diseases. CT is generally considered the most accurate choice for lung examination. Due to the growing use of CT, breast and other superficial and radiosensitive organs are unnecessarily irradiated during radiological procedures, thus requiring the development of strategies appropriate to optimize and, if possible, to reduce the radiation dose. The use of bismuth shielding to reduce radiation dose absorbed by breast during thoracic CT examinations has been the subject of many studies recently published by Brazilian and foreign authors of various fields. The purpose of this paper is both to accurately determine the glandular dose when breast is exposed to radiation and to assess the reduction in absorbed dose during thoracic CT examinations, using a set of Thermoluminescent Dosimeters, an anthropomorphic phantom and bismuth shielding. (Author)

  17. Progress in diagnosis of breast cancer: Advances in radiology technology

    Directory of Open Access Journals (Sweden)

    J Mari Beth Linder

    2015-01-01

    Full Text Available Breast cancer is the leading cause of cancer in females between the ages of 15 and 54, and the second leading cause of cancer death in women in the United States. Diagnosis begins with detection by breast examination (clinical breast exam or breast self-exam or by radiologic studies, like mammography. Many advances in the diagnosis of breast cancer have taken place in recent years. This article will review the history of radiologic advances in the diagnosis of breast cancer. Use of technological advancements in digital breast tomosynthesis, magnetic resonance imaging, and ultrasound in breast cancer diagnosis will be presented. Advantages and disadvantages of these diagnostic interventions when compared to older, traditional X-ray films will be discussed. It is important for all nurses, including radiology and oncology nurses, to be well informed about these varied diagnostic modalities, and appreciate the fact that advances in radiologic imaging technologies can yield improved outcomes for breast cancer patients.

  18. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis.

    Science.gov (United States)

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21-24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes) pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis.

  19. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis

    OpenAIRE

    Fan, Rongyan; Li, Yuanjun; Li, Changfu; Zhang, Yansheng

    2015-01-01

    The medicinal plant Xanthium strumarium L. (X. strumarium) is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs) are a class of 21-24 nucleotide (nt) non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined w...

  20. Differential microRNA Analysis of Glandular Trichomes and Young Leaves in Xanthium strumarium L. Reveals Their Putative Roles in Regulating Terpenoid Biosynthesis.

    Directory of Open Access Journals (Sweden)

    Rongyan Fan

    Full Text Available The medicinal plant Xanthium strumarium L. (X. strumarium is covered with glandular trichomes, which are the sites for synthesizing pharmacologically active terpenoids such as xanthatin. MicroRNAs (miRNAs are a class of 21-24 nucleotide (nt non-coding RNAs, most of which are identified as regulators of plant growth development. Identification of miRNAs involved in the biosynthesis of plant secondary metabolites remains limited. In this study, high-throughput Illumina sequencing, combined with target gene prediction, was performed to discover novel and conserved miRNAs with potential roles in regulating terpenoid biosynthesis in X. strumarium glandular trichomes. Two small RNA libraries from leaves and glandular trichomes of X. strumarium were established. In total, 1,185 conserved miRNAs and 37 novel miRNAs were identified, with 494 conserved miRNAs and 18 novel miRNAs being differentially expressed between the two tissue sources. Based on the X. strumarium transcriptome data that we recently constructed, 3,307 annotated mRNA transcripts were identified as putative targets of the differentially expressed miRNAs. KEGG (Kyoto Encyclopedia of Genes and Genomes pathway analysis suggested that some of the differentially expressed miRNAs, including miR6435, miR5021 and miR1134, might be involved in terpenoid biosynthesis in the X. strumarium glandular trichomes. This study provides the first comprehensive analysis of miRNAs in X. strumarium, which forms the basis for further understanding of miRNA-based regulation on terpenoid biosynthesis.

  1. Entomology contribution in animal immunity: Determination of the crude thoraxial glandular protein extract of Stomoxys calcitrans as an antibody production enhancer in young horses

    Directory of Open Access Journals (Sweden)

    L. Rumokoy

    2017-12-01

    Full Text Available This experiment was conducted to evaluate the level of antigens protein contained in the crude thoraxial glandular protein (TGP extract of Stomoxys calcitrans which function as immunity enhancer in young horses. The detection of protein content of the thoraxial glandular samples was performed by using a spectrophotometer Nano Drop-1000. This result showed that the lowest level of antigen protein was 0.54 mg/mL, the highest was 72 mg/mL, and the average was 0.675 mg/mL. Six foals were used and divided into two groups. The first group was treated with a solution of 100 μg of TGP by subcutaneous injection, the other group acted as control. The TGP extract was injected on the first day of the experiment. Three ml of blood were sampled from the jugular vein on the 14th day after TGP injection. The blood sampled was centrifuged and its serum placed in micro-tubes to observe the IgG level. The injection of TGP had a significant effect on the IgG level of the experiment animals (P<0.05. This experiment emphasized an important relation between entomology and animal husbandry; health improvement in the young animals was observed after the injection of the insect antigen, so it can be concluded that crude thoraxial glandular proteins of S. calcitrans can be used to improve the immunoglobulin-G circulation in foals.

  2. Image quality and dose assessment in digital breast tomosynthesis: A Monte Carlo study

    International Nuclear Information System (INIS)

    Baptista, M.; Di Maria, S.; Oliveira, N.; Matela, N.; Janeiro, L.; Almeida, P.; Vaz, P.

    2014-01-01

    Mammography is considered a standard technique for the early detection of breast cancer. However, its sensitivity is limited essentially due to the issue of the overlapping breast tissue. This limitation can be partially overcome, with a relatively new technique, called digital breast tomosynthesis (DBT). For this technique, optimization of acquisition parameters which maximize image quality, whilst complying with the ALARA principle, continues to be an area of considerable research. The aim of this work was to study the best quantum energies that optimize the image quality with the lowest achievable dose in DBT and compare these results with the digital mammography (DM) ones. Monte Carlo simulations were performed using the state-of-the-art computer program MCNPX 2.7.0 in order to generate several 2D cranio-caudal (CC) projections obtained during an acquisition of a standard DBT examination. Moreover, glandular absorbed doses and photon flux calculations, for each projection image, were performed. A homogeneous breast computational phantom with 50%/50% glandular/adipose tissue composition was used and two compressed breast thicknesses were evaluated: 4 cm and 8 cm. The simulated projection images were afterwards reconstructed with an algebraic reconstruction tool and the signal difference to noise ratio (SDNR) was calculated in order to evaluate the image quality in DBT and DM. Finally, a thorough comparison between the results obtained in terms of SDNR and dose assessment in DBT and DM was performed. - Highlights: • Optimization of the image quality in digital breast tomosynthesis. • Calculation of photon energies that maximize the signal difference to noise ratio. • Projections images and dose calculations through the Monte Carlo (MC) method. • Tumor masses and microcalcifications included in the MC model. • A dose saving of about 30% can be reached if optimal photon energies are used

  3. Intra-observer reproducibility and diagnostic performance of breast shear-wave elastography in Asian women.

    Science.gov (United States)

    Park, Hye Young; Han, Kyung Hwa; Yoon, Jung Hyun; Moon, Hee Jung; Kim, Min Jung; Kim, Eun-Kyung

    2014-06-01

    Our aim was to evaluate intra-observer reproducibility of shear-wave elastography (SWE) in Asian women. Sixty-four breast masses (24 malignant, 40 benign) were examined with SWE in 53 consecutive Asian women (mean age, 44.9 y old). Two SWE images were obtained for each of the lesions. The intra-observer reproducibility was assessed by intra-class correlation coefficients (ICC). We also evaluated various clinicoradiologic factors that can influence reproducibility in SWE. The ICC of intra-observer reproducibility was 0.789. In clinicoradiologic factor evaluation, masses surrounded by mixed fatty and glandular tissue (ICC: 0.619) showed lower intra-observer reproducibility compared with lesions that were surrounded by glandular tissue alone (ICC: 0.937; p breast SWE was excellent in Asian women. However, it may decrease when breast tissue is in a heterogeneous background. Therefore, SWE should be performed carefully in these cases. Copyright © 2014 World Federation for Ultrasound in Medicine & Biology. Published by Elsevier Inc. All rights reserved.

  4. Imaging dose in breast radiotherapy: does breast size affect the dose to the organs at risk and the risk of secondary cancer to the contralateral breast?

    International Nuclear Information System (INIS)

    Batumalai, Vikneswary; Quinn, Alexandra; Jameson, Michael; Delaney, Geoff; Holloway, Lois

    2015-01-01

    Correct target positioning is crucial for accurate dose delivery in breast radiotherapy resulting in utilisation of daily imaging. However, the radiation dose from daily imaging is associated with increased probability of secondary induced cancer. The aim of this study was to quantify doses associated with three imaging modalities and investigate the correlation of dose and varying breast size in breast radiotherapy. Planning computed tomography (CT) data sets of 30 breast cancer patients were utilised to simulate the dose received by various organs from a megavoltage computed tomography (MV-CT), megavoltage electronic portal image (MV-EPI) and megavoltage cone-beam computed tomography (MV-CBCT). The mean dose to organs adjacent to the target volume (contralateral breast, lungs, spinal cord and heart) were analysed. Pearson correlation analysis was performed to determine the relationship between imaging dose and primary breast volume and the lifetime attributable risk (LAR) of induced secondary cancer was calculated for the contralateral breast. The highest contralateral breast mean dose was from the MV-CBCT (1.79 Gy), followed by MV-EPI (0.22 Gy) and MV-CT (0.11 Gy). A similar trend was found for all organs at risk (OAR) analysed. The primary breast volume inversely correlated with the contralateral breast dose for all three imaging modalities. As the primary breast volume increases, the likelihood of a patient developing a radiation-induced secondary cancer to the contralateral breast decreases. MV-CBCT showed a stronger relationship between breast size and LAR of developing a radiation-induced contralateral breast cancer in comparison with the MV-CT and MV-EPI. For breast patients, imaging dose to OAR depends on imaging modality and treated breast size. When considering the use of imaging during breast radiotherapy, the patient's breast size and contralateral breast dose should be taken into account

  5. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    International Nuclear Information System (INIS)

    Rodrigues, M.J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-01-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal

  6. Breast asymmetry and predisposition to breast cancer

    OpenAIRE

    Scutt, Diane; Lancaster, Gillian A; Manning, John T

    2006-01-01

    INTRODUCTION: It has been shown in our previous work that breast asymmetry is related to several of the known risk factors for breast cancer, and that patients with diagnosed breast cancer have more breast volume asymmetry, as measured from mammograms, than age-matched healthy women. METHODS: In the present study, we compared the breast asymmetry of women who were free of breast disease at time of mammography, but who had subsequently developed breast cancer, with that of age-matched healthy ...

  7. MR STIR imaging versus spin-echo imaging of the breast

    International Nuclear Information System (INIS)

    Zobel, B.B.; Tella, S.; Patrizio, G.; Confalone, D.; D'Archivio, C.; Passariello, R.

    1989-01-01

    A valid tissue characterization of human breast diseases with conventional spin-echo (SE) sequences has not been achieved yet. In spite of experimental works showing that fibroadenomas have a small but significant difference in T1 relaxation time, T1- and T2-weighted SE sequences are not always able to differentiate them. We tried to solve the problem employing two different short T1 inversion-recovery (STIR) sequences with T1 values adequate to nullify the signal of glandular and fatty tissues. This paper reports on twenty-five nodules, including cysts, fibroadenomas, phylloids, and adenocarcinomas, examined with both STIR sequences performed on a superconductive 0.5-T unit

  8. Quantitative differentiation of breast lesions at 3T diffusion-weighted imaging (DWI) using the ratio of distributed diffusion coefficient (DDC).

    Science.gov (United States)

    Ertas, Gokhan; Onaygil, Can; Akin, Yasin; Kaya, Handan; Aribal, Erkin

    2016-12-01

    To investigate the accuracy of diffusion coefficients and diffusion coefficient ratios of breast lesions and of glandular breast tissue from mono- and stretched-exponential models for quantitative diagnosis in diffusion-weighted magnetic resonance imaging (MRI). We analyzed pathologically confirmed 170 lesions (85 benign and 85 malignant) imaged using a 3.0T MR scanner. Small regions of interest (ROIs) focusing on the highest signal intensity for lesions and also for glandular tissue of contralateral breast were obtained. Apparent diffusion coefficient (ADC) and distributed diffusion coefficient (DDC) were estimated by performing nonlinear fittings using mono- and stretched-exponential models, respectively. Coefficient ratios were calculated by dividing the lesion coefficient by the glandular tissue coefficient. A stretched exponential model provides significantly better fits then the monoexponential model (P DDC ratio (area under the curve [AUC] = 0.93) when compared with lesion DDC, ADC ratio, and lesion ADC (AUC = 0.91, 0.90, 0.90) but with no statistically significant difference (P > 0.05). At optimal thresholds, the DDC ratio achieves 93% sensitivity, 80% specificity, and 87% overall diagnostic accuracy, while ADC ratio leads to 89% sensitivity, 78% specificity, and 83% overall diagnostic accuracy. The stretched exponential model fits better with signal intensity measurements from both lesion and glandular tissue ROIs. Although the DDC ratio estimated by using the model shows a higher diagnostic accuracy than the ADC ratio, lesion DDC, and ADC, it is not statistically significant. J. Magn. Reson. Imaging 2016;44:1633-1641. © 2016 International Society for Magnetic Resonance in Medicine.

  9. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  10. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    International Nuclear Information System (INIS)

    Hernandez, A; Boone, J

    2016-01-01

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  11. Mammographic findings after reshaping with autoprosthesis in women undergoing contralateral breast reconstruction and mastectomy.

    Science.gov (United States)

    Scaperrotta, Gianfranco; Capalbo, Emanuela; Ferranti, Claudio; Falco, Giuseppe; Nava, Maurizio B; Di Leo, Gianni; Marchesini, Monica; Suman, Laura; Panizza, Pietro

    2016-01-01

    Breast reduction and mastopexy combined with inferior dermo-lipo-glandular flap (autoprosthesis) gives good breast shape, long-term projection, and upper pole fullness. We assess the impact on breast oncologic surveillance compared to other techniques. A total of 105 patients who underwent mastectomy and reconstruction were divided into 3 groups of 35 patients each: groups 1 and 2 include patients with contralateral breast symmetrization performed with and without autoprosthesis technique, respectively. Group 3 is a control group without contralateral breast reshaping. On mammography, edema, skin thickening, architectural distortion, and calcifications were recorded, as well as further diagnostic examinations, biopsies, and surgical treatments required. Statistically significant differences (p<0.001) in the first follow-up mammography between groups 1 and 2 were stromal edema (6% vs 51%) and architectural distortion (74% vs 63%). The latest findings meant architectural distortion also have significant difference (p<0.001) in the last mammography (79% vs 66%). Microcalcification has statistically significant difference (p<0.001) in the latest postsurgical mammography, increased in group 1. Skin thickening had a similar course in either group. Mammography follow-up was not impaired in most cases notwithstanding the parenchyma distortion as compared with mammography after breast-conserving surgery. Four core biopsies were performed in both groups: 3 new breast cancers and 1 benign epithelial hyperplasia were found. No difficulties were found impairing mammographic evaluation in patients treated with autoprosthesis as compared to other techniques.

  12. Breast cancer

    International Nuclear Information System (INIS)

    Tokunaga, Masayoshi

    1992-01-01

    More than 20-year follow-up of A-bomb survivors in Hiroshima and Nagasaki has a crucial role in determining the relationship of radiation to the occurrence of breast cancer. In 1967, Wanebo et al have first reported 27 cases of breast cancer during the period 1950-1966 among the Adult Health Study population of A-bomb survivors. Since then, follow-up surveys for breast cancer have been made using the Life Span Study (LSS) cohort, and the incidence of breast cancer has increased year by year; that is breast cancer was identified in 231 cases by the first LSS series (1950-1969), 360 cases by the second LSS series (1950-1974), 564 cases by the third LSS series (1950-1980), and 816 cases in the fourth LSS series (1950-1085). The third LSS series have revealed a high risk for radiation-induced breast cancer in women aged 10 or less at the time of exposure (ATE). Both relative and absolute risks are found to be decreased with increasing ages ATE. Based on the above-mentioned findings and other studies on persons exposed medical radiation, radiation-induced breast cancer is characterized by the following: (1) the incidence of breast cancer is linearly increased with increasing radiation doses; (2) both relative and absolute risks for breast cancer are high in younger persons ATE; (3) age distribution of breast cancer in proximally exposed A-bomb survivors is the same as that in both distally A-bomb survivors and non-exposed persons, and there is no difference in histology between the former and latter groups. Thus, immature mammary gland cells before the age of puberty are found to be most radiosensitive. (N.K.)

  13. Radiography of the male breast in gynecomastia

    Energy Technology Data Exchange (ETDEWEB)

    Rissanen, T.J.; Maekaeraeinen, H.P.; Kallioinen, M.J.; Kiviniemi, H.O.; Salmela, P.I. (Oulu Univ. Central Hospital (Finland). Depts. of Diagnostic Radiology, Pathology, Surgery, and Internal Medicine)

    1992-03-01

    In order to investigate the role of imaging methods in the evaluation of the male breast we reviewed the mammograms and ultrasonograms (US) performed in 40 men with breast enlargement or pain. The patients, whose breasts were examined by either mammography or US or both, ranged in age from 14 to 83 years. The final diagnoses were gynecomastia in 35 patients, lipomas in one, abscess or sequelae to abscess in 2, and normal in 2. In gynecomastia the subareolar density was of varying shape and size or showed a diffuse pattern of heterogeneous density occupying the whole breast on mammography, and a retromammillar hypoechoic focus, a diffuse heterogeneous area, or a combination of these was observed at US. Mammography is recommended for the evaluation of the male breast if the differential diagnosis between gynecomastia and fatty enlargement is not clinically evident, and in all cases of unilateral breast symptoms. US is a complementary method to mammography. (orig.).

  14. Radiography of the male breast in gynecomastia

    International Nuclear Information System (INIS)

    Rissanen, T.J.; Maekaeraeinen, H.P.; Kallioinen, M.J.; Kiviniemi, H.O.; Salmela, P.I.

    1992-01-01

    In order to investigate the role of imaging methods in the evaluation of the male breast we reviewed the mammograms and ultrasonograms (US) performed in 40 men with breast enlargement or pain. The patients, whose breasts were examined by either mammography or US or both, ranged in age from 14 to 83 years. The final diagnoses were gynecomastia in 35 patients, lipomas in one, abscess or sequelae to abscess in 2, and normal in 2. In gynecomastia the subareolar density was of varying shape and size or showed a diffuse pattern of heterogeneous density occupying the whole breast on mammography, and a retromammillar hypoechoic focus, a diffuse heterogeneous area, or a combination of these was observed at US. Mammography is recommended for the evaluation of the male breast if the differential diagnosis between gynecomastia and fatty enlargement is not clinically evident, and in all cases of unilateral breast symptoms. US is a complementary method to mammography. (orig.)

  15. SU-F-I-14: 3D Breast Digital Phantom for XACT Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Tang, S; Laaroussi, R; Chen, J; Samant, P; Xiang, L [University of Oklahoma, Norman, OK (United States); Chen, Y; Ahmad, S [University of Oklahoma Health Sciences Center, Oklahoma City, OK (United States); Yang, K [Massachusetts General Hospital, Boston, MA (United States)

    2016-06-15

    Purpose: The X-ray induced acoustic computed tomography (XACT) is a new imaging modality which combines X-ray contrast and high ultrasonic resolution in a single modality. Using XACT in breast imaging, a 3D breast volume can be imaged by only one pulsed X-ray radiation, which could dramatically reduce the imaging dose for patients undergoing breast cancer screening and diagnosis. A 3D digital phantom that contains both X-ray properties and acoustic properties of different tissue types is indeed needed for developing and optimizing the XACT system. The purpose of this study is to offer a realistic breast digital phantom as a valuable tool for improving breast XACT imaging techniques and potentially leading to better diagnostic outcomes. Methods: A series of breast CT images along the coronal plane from a patient who has breast calcifications are used as the source images. A HU value based segmentation algorithm is employed to identify breast tissues in five categories, namely the skin tissue, fat tissue, glandular tissue, chest bone and calcifications. For each pixel, the dose related parameters, such as material components and density, and acoustic related parameters, such as frequency-dependent acoustic attenuation coefficient and bandwidth, are assigned based on tissue types. Meanwhile, other parameters which are used in sound propagation, including the sound speed, thermal expansion coefficient, and heat capacity are also assigned to each tissue. Results: A series of 2D tissue type image is acquired first and the 3D digital breast phantom is obtained by using commercial 3D reconstruction software. When giving specific settings including dose depositions and ultrasound center frequency, the X-ray induced initial pressure rise can be calculated accordingly. Conclusion: The proposed 3D breast digital phantom represents a realistic breast anatomic structure and provides a valuable tool for developing and evaluating the system performance for XACT.

  16. The Cellient automated cell block system is useful in the differential diagnosis of atypical glandular cells in Papanicolaou tests.

    Science.gov (United States)

    Xing, Wei; Hou, April Y; Fischer, Andrew; Owens, Christopher L; Jiang, Zhong

    2014-01-01

    Atypical glandular cells (AGC) is a very important diagnosis in gynecological cytology. In the current study, the authors investigated the usefulness of Cellient cell blocks (CB) for characterizing AGC on Papanicolaou (Pap) tests. A total of 148 patients with an AGC diagnosis based on Pap tests by cytotechnologists and referred to cytopathologists were studied. Among these patients, there were 68 patients with CB preparations and 80 patients with Pap tests only (TP-AGC group). Follow-up results by Pap tests or biopsies were obtained in 117 of 148 patients. The median follow-up was 13 months (range, 1 month-36 months). Of the 68 patients with CBs, 31 (46%) were reclassified as negative for dysplasia or low-grade intraepithelial lesion; 30 patients (44%) retained a diagnosis of AGC (CB-AGC group); and 7 patients (10%) were given specific diagnoses of high-grade intraepithelial lesion (3 patients), endocervical adenocarcinoma in situ (1 patient), and invasive adenocarcinoma (3 patients). On follow-up, the CB-AGC group was found to have a significantly lower rate of negative/low-grade squamous intraepithelial lesion diagnoses compared with the TP-AGC group (55% vs 85%; P= .006). The CB-AGC group had a significantly higher rate of endocervical or endometrial adenocarcinoma compared with the TP-AGC group (36% vs 8%; P= .003) at the time of follow-up. The rates of high-grade squamous intraepithelial lesion were not found to be statistically different between these 2 groups (9% vs 7%; P= .66). The Cellient CB is a useful technique to further categorize a diagnosis of AGC on Pap tests. Using the Cellient CB system, the pathologist has the ability to improve the diagnostic accuracy of AGC so that unnecessary colposcopic evaluation or biopsies can be avoided. © 2013 American Cancer Society.

  17. Analysis of previous screening examinations for patients with breast cancer

    International Nuclear Information System (INIS)

    Lee, Eun Hye; Cha, Joo Hee; Han, Dae Hee; Choi, Young Ho; Hwang, Ki Tae; Ryu, Dae Sik; Kwak, Jin Ho; Moon, Woo Kyung

    2007-01-01

    We wanted to improve the quality of subsequent screening by reviewing the previous screening of breast cancer patients. Twenty-four breast cancer patients who underwent previous screening were enrolled. All 24 took mammograms and 15 patients also took sonograms. We reviewed the screening retrospectively according to the BI-RADS criteria and we categorized the results into false negative, true negative, true positive and occult cancers. We also categorized the causes of false negative cancers into misperception, misinterpretation and technical factors and then we analyzed the attributing factors. Review of the previous screening revealed 66.7% (16/24) false negative, 25.0% (6/24) true negative, and 8.3% (2/24) true positive cancers. False negative cancers were caused by the mammogram in 56.3% (9/16) and by the sonogram in 43.7% (7/16). For the false negative cases, all of misperception were related with mammograms and this was attributed to dense breast, a lesion located at the edge of glandular tissue or the image, and findings seen on one view only. Almost all misinterpretations were related with sonograms and attributed to loose application of the final assessment. To improve the quality of breast screening, it is essential to overcome the main causes of false negative examinations, including misperception and misinterpretation. We need systematic education and strict application of final assessment categories of BI-RADS. For effective communication among physicians, it is also necessary to properly educate them about BI-RADS

  18. Radiation doses in volume-of-interest breast computed tomography—A Monte Carlo simulation study

    Energy Technology Data Exchange (ETDEWEB)

    Lai, Chao-Jen, E-mail: cjlai3711@gmail.com; Zhong, Yuncheng; Yi, Ying; Wang, Tianpeng; Shaw, Chris C. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States)

    2015-06-15

    Purpose: Cone beam breast computed tomography (breast CT) with true three-dimensional, nearly isotropic spatial resolution has been developed and investigated over the past decade to overcome the problem of lesions overlapping with breast anatomical structures on two-dimensional mammographic images. However, the ability of breast CT to detect small objects, such as tissue structure edges and small calcifications, is limited. To resolve this problem, the authors proposed and developed a volume-of-interest (VOI) breast CT technique to image a small VOI using a higher radiation dose to improve that region’s visibility. In this study, the authors performed Monte Carlo simulations to estimate average breast dose and average glandular dose (AGD) for the VOI breast CT technique. Methods: Electron–Gamma-Shower system code-based Monte Carlo codes were used to simulate breast CT. The Monte Carlo codes estimated were validated using physical measurements of air kerma ratios and point doses in phantoms with an ion chamber and optically stimulated luminescence dosimeters. The validated full cone x-ray source was then collimated to simulate half cone beam x-rays to image digital pendant-geometry, hemi-ellipsoidal, homogeneous breast phantoms and to estimate breast doses with full field scans. 13-cm in diameter, 10-cm long hemi-ellipsoidal homogeneous phantoms were used to simulate median breasts. Breast compositions of 25% and 50% volumetric glandular fractions (VGFs) were used to investigate the influence on breast dose. The simulated half cone beam x-rays were then collimated to a narrow x-ray beam with an area of 2.5 × 2.5 cm{sup 2} field of view at the isocenter plane and to perform VOI field scans. The Monte Carlo results for the full field scans and the VOI field scans were then used to estimate the AGD for the VOI breast CT technique. Results: The ratios of air kerma ratios and dose measurement results from the Monte Carlo simulation to those from the physical

  19. Breast ultrasound in the management of gynecomastia in Peutz-Jeghers syndrome in monozygotic twins: two case reports.

    Science.gov (United States)

    Di Grezia, Graziella; Romano, Tiziana; De Francesco, Francesco; Somma, Francesco; Rea, Gaetano; Grassi, Roberto; Gatta, Gianluca

    2014-12-18

    Peutz-Jeghers syndrome is an autosomal dominant disease with incomplete penetrance and variable expression caused by germline mutation of serine threonine kinase 11/liver kinase B1; it is characterized by hamartomatous polyps in the gastrointestinal tract, mucocutaneous melanin pigmentation, and increased predisposition to neoplasms. In Peutz-Jeghers syndrome, bilateral Sertoli cell testicular tumors cause endocrine manifestations including gynecomastia and feminization. This study aimed to assess the role of breast ultrasound in the evaluation of the effectiveness of an innovative surgical approach. This report presents a pair of European 9-year-old identical male twins with Peutz-Jeghers syndrome, bilateral prepubertal gynecomastia, and testicular multifocal calcifications. Both twins were treated with anastrozole for 2 years. After finishing treatment, both underwent subcutaneous mastectomy performed by the "modified" Webster technique. Breast examination and ultrasound were performed before and after the pharmacological and surgical treatment. A breast ultrasound scan before surgery showed bilateral gynecomastia in both patients. No solid nodular or cystic formations were present on either side. After pharmacological therapy and surgical glandular removal, a breast examination showed a significant reduction in breast volume; 1 year after surgery, a breast ultrasound scan of both patients showed a total absence of glandular parenchyma, with muscle planes well represented. Breast examination and ultrasound have proved to be a valid approach in the assessment of the treatment of prepubertal gynecomastia because they allow the efficacy of the pharmacological and surgical treatment to be evaluated in a multidisciplinary approach to one of the most frequent endocrine manifestations of Peutz-Jeghers syndrome.

  20. Evaluation of dose calculation variations between manual 2D and 3D TPS for breast carcinoma

    International Nuclear Information System (INIS)

    Goswami, Pradeep; Oinam, A.S.; Kumar, Anup; Sharma, S.C.; Rana, B.S.

    2008-01-01

    The anatomy of breast varies in a complex shape. These gross variations of anatomy of intact breast and mastectomy breast pose a definite dose inhomogeniety in the chest wall being treated. 6MV photon energy from medium energy accelerator is a good choice for the treatment of lumpectomy breast (intact) as conservative management. Most of the centers use the manual 2D calculations for breast planning using the midline separation

  1. Breast reconstruction - natural tissue

    Science.gov (United States)

    ... flap; TRAM; Latissimus muscle flap with a breast implant; DIEP flap; DIEAP flap; Gluteal free flap; Transverse upper gracilis flap; TUG; Mastectomy - breast reconstruction with natural tissue; Breast cancer - breast reconstruction with natural tissue

  2. Breast Cancer: Treatment Options

    Science.gov (United States)

    ... Breast Cancer > Breast Cancer: Treatment Options Request Permissions Breast Cancer: Treatment Options Approved by the Cancer.Net Editorial ... can be addressed as quickly as possible. Recurrent breast cancer If the cancer does return after treatment for ...

  3. Breast cancer

    International Nuclear Information System (INIS)

    Delgado, L.; Krygier, G.; Castillo, C.

    2009-01-01

    This article is about the diagnosis, treatment and monitoring of breast cancer. Positive diagnosis is based on clinical mammary exam, mammography, mammary ultrasonography, and histological study. Before the chemotherapy and radiotherapy treatment are evaluated the risks

  4. Breast Augmentation

    Science.gov (United States)

    ... Administration (FDA) has identified a possible association between breast implants and the development of anaplastic large cell lymphoma (ALCL), a rare cancer of the immune system. The FDA believes that ...

  5. Breast Augmentation

    African Journals Online (AJOL)

    1974-04-13

    Apr 13, 1974 ... Complications encountered after breast augmentation are dealt with in .... in Phisohex or other suitable preparation for a few days before surgery ... In all cases, the prosthesis causes a fibrous tissue capsule to form around it.

  6. Breast Cancer

    Science.gov (United States)

    ... modulators and aromatase inhibitors, reduce the risk of breast cancer in women with a high risk of the disease. These medications carry a risk of side effects, so doctors reserve these medications for women who ...

  7. A software-based x-ray scatter correction method for breast tomosynthesis

    International Nuclear Information System (INIS)

    Jia Feng, Steve Si; Sechopoulos, Ioannis

    2011-01-01

    Purpose: To develop a software-based scatter correction method for digital breast tomosynthesis (DBT) imaging and investigate its impact on the image quality of tomosynthesis reconstructions of both phantoms and patients. Methods: A Monte Carlo (MC) simulation of x-ray scatter, with geometry matching that of the cranio-caudal (CC) view of a DBT clinical prototype, was developed using the Geant4 toolkit and used to generate maps of the scatter-to-primary ratio (SPR) of a number of homogeneous standard-shaped breasts of varying sizes. Dimension-matched SPR maps were then deformed and registered to DBT acquisition projections, allowing for the estimation of the primary x-ray signal acquired by the imaging system. Noise filtering of the estimated projections was then performed to reduce the impact of the quantum noise of the x-ray scatter. Three dimensional (3D) reconstruction was then performed using the maximum likelihood-expectation maximization (MLEM) method. This process was tested on acquisitions of a heterogeneous 50/50 adipose/glandular tomosynthesis phantom with embedded masses, fibers, and microcalcifications and on acquisitions of patients. The image quality of the reconstructions of the scatter-corrected and uncorrected projections was analyzed by studying the signal-difference-to-noise ratio (SDNR), the integral of the signal in each mass lesion (integrated mass signal, IMS), and the modulation transfer function (MTF). Results: The reconstructions of the scatter-corrected projections demonstrated superior image quality. The SDNR of masses embedded in a 5 cm thick tomosynthesis phantom improved 60%-66%, while the SDNR of the smallest mass in an 8 cm thick phantom improved by 59% (p < 0.01). The IMS of the masses in the 5 cm thick phantom also improved by 15%-29%, while the IMS of the masses in the 8 cm thick phantom improved by 26%-62% (p < 0.01). Some embedded microcalcifications in the tomosynthesis phantoms were visible only in the scatter

  8. A computer simulation study comparing lesion detection accuracy with digital mammography, breast tomosynthesis, and cone-beam CT breast imaging

    International Nuclear Information System (INIS)

    Gong Xing; Glick, Stephen J.; Liu, Bob; Vedula, Aruna A.; Thacker, Samta

    2006-01-01

    Although conventional mammography is currently the best modality to detect early breast cancer, it is limited in that the recorded image represents the superposition of a three-dimensional (3D) object onto a 2D plane. Recently, two promising approaches for 3D volumetric breast imaging have been proposed, breast tomosynthesis (BT) and CT breast imaging (CTBI). To investigate possible improvements in lesion detection accuracy with either breast tomosynthesis or CT breast imaging as compared to digital mammography (DM), a computer simulation study was conducted using simulated lesions embedded into a structured 3D breast model. The computer simulation realistically modeled x-ray transport through a breast model, as well as the signal and noise propagation through a CsI based flat-panel imager. Polyenergetic x-ray spectra of Mo/Mo 28 kVp for digital mammography, Mo/Rh 28 kVp for BT, and W/Ce 50 kVp for CTBI were modeled. For the CTBI simulation, the intensity of the x-ray spectra for each projection view was determined so as to provide a total average glandular dose of 4 mGy, which is approximately equivalent to that given in conventional two-view screening mammography. The same total dose was modeled for both the DM and BT simulations. Irregular lesions were simulated by using a stochastic growth algorithm providing lesions with an effective diameter of 5 mm. Breast tissue was simulated by generating an ensemble of backgrounds with a power law spectrum, with the composition of 50% fibroglandular and 50% adipose tissue. To evaluate lesion detection accuracy, a receiver operating characteristic (ROC) study was performed with five observers reading an ensemble of images for each case. The average area under the ROC curves (A z ) was 0.76 for DM, 0.93 for BT, and 0.94 for CTBI. Results indicated that for the same dose, a 5 mm lesion embedded in a structured breast phantom was detected by the two volumetric breast imaging systems, BT and CTBI, with statistically

  9. Male breast disease: clinical, mammographic, and ultrasonographic features

    International Nuclear Information System (INIS)

    Guenhan-Bilgen, Isil; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-01-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination

  10. Male breast disease: clinical, mammographic, and ultrasonographic features

    Energy Technology Data Exchange (ETDEWEB)

    Guenhan-Bilgen, Isil E-mail: isilbilgen@hotmail.com; Bozkaya, Halil; Uestuen, Esin Emin; Memis, Aysenur

    2002-09-01

    Purpose: To describe and quantitate the radiological (mammographic and ultrasonographic) characteristics of male breast disease and to report the clinical and pathological findings. Materials and methods: Two-hundred-thirty-six male patients with different male breast diseases, diagnosed at our institution between January 1990 and July 2001, were retrospectively evaluated. The history, physical examination, mammographic and ultrasonographic findings were analyzed. Results: The spectrum of the disease in 236 male patients were gynecomastia (n=206), primary breast carcinoma (n=14), fat necrosis (n=5), lipoma (n=3), subareolar abscess (n=2), epidermal inclusion cyst (n=1), sebaceous cyst (n=1), hematoma (n=1), myeloma (n=1), and metastatic carcinoma (n=2). The distribution of patterns of gynecomastia were; 34% (n=71) nodular, 35% (n=73) dendritic and 31% (n=62) diffuse glandular. Gynecomastia was unilateral in 55% (n=113) and bilateral in 45% (n=93) of the patients. Male breast cancer presented as a mass without microcalcifications in 86% (n=12) and with microcalcifications in 7% (n=1) of patients. The mass was obscured by gynecomastia, partially in two, totally in one patient. The location of the mass was retroareolar in 46% (n=6) and eccentric to the nipple in 54% (n=7) of patients. On ultrasonography (US), the contours were well-circumscribed in 20% (n=3) and irregular in 80% (n=12) of the masses. Conclusion: Male breast has a wide spectrum of diseases, some of which have characteristic radiological appearances that can be correlated with their pathologic diagnosis. In the evaluation of the male breast, mammography and US are essential and should be performed along with physical examination.

  11. Preoperative Saline Implant Deflation in Revisional Aesthetic Breast Surgery.

    Science.gov (United States)

    Wu, Cindy; Grotting, James C

    2015-09-01

    Preoperative saline deflation is a clinically useful intervention in revisional breast surgery. It allows suspensory ligament recovery, reveals true glandular volume, and simplifies mastopexy markings. Presently unknown are the volumetric changes that occur after deflation. The authors report the three-dimensional (3D) changes that occur with preoperative deflation prior to revisional breast surgery. We reviewed available charts of revisional breast surgery patients who underwent preliminary saline implant deflation. Our protocol is deflation 4 weeks prior to revision. Three weeks following deflation, the patient is evaluated to finalize the operative plan, including the need for implants, mastopexy, and adjunctive procedures. A subset underwent 3D imaging to quantify the volumetric changes over the 3-week deflation period. Between 2002 and 2014, 55 patients underwent saline implant deflation prior to 57 revisional surgeries. Seventeen were revised without implants and 40 with implants. The 3D subset of 10 patients showed a mean 15.2% volume increase and 0.18 cm notch-to-nipple distance decrease over the 3 weeks following deflation and prior to definitive surgical correction. Breast volume increases and the notch-to-nipple distance decreases during the 3-week interval prior to reoperation. This "elastic breast recoil" occurs after the mass effect of the implant is removed, resulting in recovery of stretched suspensory ligaments and gland reexpansion. We believe 4 weeks is optimal for gland normalization. Ideal candidates include patients requiring secondary mastopexy without implants, implant downsizing in the same pocket, and secondary augmentation mastopexy. Preoperative saline deflation and 3D analyses are useful for preoperative planning in reoperative breast surgery. © 2015 The American Society for Aesthetic Plastic Surgery, Inc. Reprints and permission: journals.permissions@oup.com.

  12. Sarcoglycans in the normal and pathological breast tissue of humans: an immunohistochemical and molecular study.

    Science.gov (United States)

    Arco, Alba; Favaloro, Angelo; Gioffrè, Mara; Santoro, Giuseppe; Speciale, Francesco; Vermiglio, Giovanna; Cutroneo, Giuseppina

    2012-01-01

    The sarcoglycan complex, consisting of α-, β-, γ-, δ- and ε-sarcoglycans, is a multimember transmembrane system providing a mechanosignaling connection from the cytoskeleton to the extracellular matrix. Whereas the expression of α- and γ-sarcoglycan is restricted to striated muscle, other sarcoglycans are widely expressed. Although many studies have investigated sarcoglycans in all muscle types, insufficient data are available on the distribution of the sarcoglycan complex in nonmuscle tissue. On this basis, we used immunohistochemical and RT-PCR techniques to study preliminarily the sarcoglycans in normal glandular breast tissue (which has never been studied in the literature on these proteins) to verify the effective wider distribution of this complex. Moreover, to understand the role of sarcoglycans, we also tested samples obtained from patients affected by fibrocystic mastopathy and breast fibroadenoma. Our data showed, for the first time, that all sarcoglycans are always detectable in all normal samples both in epithelial and myoepithelial cells; in pathological breast tissue, all sarcoglycans appeared severely reduced. These data demonstrated that all sarcoglycans, not only β-, δ-, and ε-sarcoglycans, have a wider distribution, implying a new unknown role for these proteins. Moreover, in breast diseases, sarcoglycans containing cadherin domain homologs could provoke a loss of strong adhesion between epithelial cells, permitting and facilitating the degeneration of these benign breast tumors into malignant tumors. Consequently, sarcoglycans could play an important and intriguing role in many breast diseases and in particular in tumor progression from benign to malignant. Copyright © 2011 S. Karger AG, Basel.

  13. Antibodies against Escherichia coli O24 and O56 O-Specific Polysaccharides Recognize Epitopes in Human Glandular Epithelium and Nervous Tissue

    Science.gov (United States)

    Korzeniowska-Kowal, Agnieszka; Kochman, Agata; Gamian, Elżbieta; Lis-Nawara, Anna; Lipiński, Tomasz; Seweryn, Ewa; Ziółkowski, Piotr; Gamian, Andrzej

    2015-01-01

    Lipopolysaccharide (LPS), the major component of the outer membrane of Gram-negative bacteria, contains the O-polysaccharide, which is important to classify bacteria into different O-serological types within species. The O-polysaccharides of serotypes O24 and O56 of E. coli contain sialic acid in their structures, already established in our previous studies. Here, we report the isolation of specific antibodies with affinity chromatography using immobilized lipopolysaccharides. Next, we evaluated the reactivity of anti-O24 and anti-O56 antibody on human tissues histologically. The study was conducted under the assumption that the sialic acid based molecular identity of bacterial and tissue structures provides not only an understanding of the mimicry-based bacterial pathogenicity. Cross-reacting antibodies could be used to recognize specific human tissues depending on their histogenesis and differentiation, which might be useful for diagnostic purposes. The results indicate that various human tissues are recognized by anti-O24 and anti-O56 antibodies. Interestingly, only a single specific reactivity could be found in the anti-O56 antibody preparation. Several tissues studied were not reactive with either antibody, thus proving that the presence of cross-reactive antigens was tissue specific. In general, O56 antibody performed better than O24 in staining epithelial and nervous tissues. Positive staining was observed for both normal (ganglia) and tumor tissue (ganglioneuroma). Epithelial tissue showed positive staining, but an epitope recognized by O56 antibody should be considered as a marker of glandular epithelium. The reason is that malignant glandular tumor and its metastasis are stained, and also epithelium of renal tubules and glandular structures of the thyroid gland are stained. Stratified epithelium such as that of skin is definitely not stained. Therefore, the most relevant observation is that the epitope recognized by anti-O56 antibodies is a new marker

  14. Morfoanatomia, tricomas glandulares e fitoquímica de Lomatozona artemisiifolia Baker (ASTERACEAE - EUPATORIEAE) - uma planta endêmica do Cerrado de Goiás

    OpenAIRE

    Trindade, Luma Mota Palmeira

    2013-01-01

    Morfoanatomia, tricomas glandulares e fitoquímica de Lomatozona artemisiifolia Baker (Asteraceae - Eupatorieae) – Uma planta endêmica do cerrado de Goiás - A família Asteraceae é amplamente distribuída, possuindo 24.000 espécies e 1.600 a 1700 gêneros, constituindo uma das maiores famílias de fanerógamas. No Cerrado, dentre as fanerógamas, é a segunda maior família em quantidade de espécies. Dentre as inúmeras espécies de Asteraceae está presente Lomatozona artemisiifolia Baker, pertence à tr...

  15. Experimental investigation for determination of optimal X-ray beam tube voltages in a newly developed digital breast tomosynthesis system

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hye-Suk, E-mail: radiosugar@yonsei.ac.kr [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju, Gangwon 220-710 (Korea, Republic of); Kim, Ye-Seul, E-mail: radiohesugar@gmail.com [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju, Gangwon 220-710 (Korea, Republic of); Choi, Young-Wook, E-mail: ywchoi@keri.re.kr [Korea Electrotechnology Research Institute (KERI), Ansan, Geongki 426-170 (Korea, Republic of); Choi, JaeGu, E-mail: jgchoi88@paran.com [Korea Electrotechnology Research Institute (KERI), Ansan, Geongki 426-170 (Korea, Republic of); Rhee, Yong-Chun, E-mail: ycrhee@yonsei.ac.kr [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju, Gangwon 220-710 (Korea, Republic of); Kim, Hee-Joung, E-mail: hjk1@yonsei.ac.kr [Department of Radiological Science and Research Institute of Health Science, Yonsei University, Wonju, Gangwon 220-710 (Korea, Republic of)

    2014-11-01

    Our purpose was to investigate optimal tube voltages (kVp) for a newly developed digital breast tomosynthesis (DBT) process and to determine tube current–exposure time products (mA s) for the average glandular dose (AGD), which is similar to that of the two views in conventional mammography (CM). In addition, the optimal acquisition parameters for this system were compared with those of CM. The analysis was based on the contrast-to-noise ratio (CNR) from the simulated micro-calcifications on homogeneous phantoms, and the figure of merit (FOM) was retrieved from the CNR and AGD at X-ray tube voltages ranging from 24 to 40 kVp at intervals of 2 kV. The optimal kVp increased more than 2 kV with increasing glandularity for thicker (≥50 mm) breast phantoms. The optimal kVp for DBT was found to be 4–7 kV higher than that calculated for CM with breast phantoms thicker than 50 mm. This is likely due to the greater effect of noise and dose reduction by kVp increment when using the lower dose per projection in DBT. It is important to determine optimum acquisition conditions for a maximally effective DBT system. The results of our study provide useful information to further improve DBT for high quality imaging.

  16. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    Energy Technology Data Exchange (ETDEWEB)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung [Hallym Univ. College of Medicine, Seoul (Korea, Republic of)

    1997-10-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity.

  17. MR imaging of multiple fibroadenoma in breast: comparison with color doppler images and histologic findings

    International Nuclear Information System (INIS)

    Chung, Soo Young; Yang, Ik; Park, Hai Jung; Lee, Yul; Chung, Bong Wha; Ahn, Hye Kyung

    1997-01-01

    To understand the different signal intensities seen on contrast enhanced magnetic resonance imaging (MRI) in multiple fibroadenoma of the breast, and to compare these with color Doppler ultrasonographic (CDUS) and histologic findings. MRI (1.0 Tesla, TIWI, T2WI, 3D-gradient echo dynamic contrast enhancement study) findings of 24 histologically proven cases of fibroadenoma in five patients were evaluated and compared with the histologic components (myxoid, adenomatous, fibrous). In addition, vascular flow, as seen on CDUS and histologic section, was compared. The observed degree of signal intensity waw classified into three groups, as follows: negative, 8.3%, mild to moderate, 54.2%; marked, 37.5%. On histologic section, the greater the fibrotic component, the higher the intensity of MRI enhancement, the greater the glandular component, and the intensity. CDUS showed vascular flow in only one tumor larger than 3cm in diameter. Vascular patterns of tumors on CDUS were dots in mass and detouring pattern, but in this case and in strongly enhanced cases, tumor vascularity-as seen on histologic section-showed no significant increase. Different signal intensities seen on contrast enhanced MRI in multiple fibroadenoma of the breast may be related more to the amount of glandular and fibrotic component than to increased tumor vascularity

  18. Time-varying Crash Risk

    DEFF Research Database (Denmark)

    Christoffersen, Peter; Feunoua, Bruno; Jeon, Yoontae

    We estimate a continuous-time model with stochastic volatility and dynamic crash probability for the S&P 500 index and find that market illiquidity dominates other factors in explaining the stock market crash risk. While the crash probability is time-varying, its dynamic depends only weakly on re...

  19. Eestlased Karlovy Varys / J. R.

    Index Scriptorium Estoniae

    J. R.

    2007-01-01

    Ilmar Raagi mängufilm "Klass" osaleb 42. Karlovy Vary rahvusvahelise filmifestivali võistlusprogrammis "East of the West" ja Asko Kase lühimängufilm "Zen läbi prügi" on valitud festivali kõrvalprogrammi "Forum of Independents"

  20. Esmaklassiline Karlovy Vary / Jaanus Noormets

    Index Scriptorium Estoniae

    Noormets, Jaanus

    2007-01-01

    Ilmar Raagi mängufilm "Klass" võitis 42. Karlovy Vary rahvusvahelise filmifestivalil kaks auhinda - ametliku kõrvalvõistlusprogrammi "East of the West" eripreemia "Special mention" ja Euroopa väärtfilmikinode keti Europa Cinemas preemia. Ka Asko Kase lühifilmi "Zen läbi prügi linastumisest ning teistest auhinnasaajatest ning osalejatest

  1. Optimistlik Karlovy Vary / Jaan Ruus

    Index Scriptorium Estoniae

    Ruus, Jaan, 1938-2017

    2007-01-01

    42. Karlovy Vary rahvusvahelise filmifestivali auhinnatud filmidest (žürii esimees Peter Bart). Kristallgloobuse sai Islandi-Saksamaa "Katseklaasilinn" (režii Baltasar Kormakur), parimaks režissööriks tunnistati norralane Bard Breien ("Negatiivse mõtlemise kunst"). Austraallase Michael James Rowlandi "Hea õnne teekond" sai žürii eripreemia

  2. Screening for breast cancer with mammography

    DEFF Research Database (Denmark)

    Gøtzsche, Peter C; Nielsen, Margrethe

    2009-01-01

    BACKGROUND: A variety of estimates of the benefits and harms of mammographic screening for breast cancer have been published and national policies vary. OBJECTIVES: To assess the effect of screening for breast cancer with mammography on mortality and morbidity. SEARCH STRATEGY: We searched Pub...... excluded a biased trial and included 600,000 women in the analyses. Three trials with adequate randomisation did not show a significant reduction in breast cancer mortality at 13 years (relative risk (RR) 0.90, 95% confidence interval (CI) 0.79 to 1.02); four trials with suboptimal randomisation showed...... a significant reduction in breast cancer mortality with an RR of 0.75 (95% CI 0.67 to 0.83). The RR for all seven trials combined was 0.81 (95% CI 0.74 to 0.87). We found that breast cancer mortality was an unreliable outcome that was biased in favour of screening, mainly because of differential...

  3. Radiation doses in mammography as planning parameters for premature breast cancer tracking programs

    International Nuclear Information System (INIS)

    Souza Ferreira, Rubemar de.

    1994-01-01

    Radiation doses are the main parameters applied to the evaluation of mammographic radiological impact. This study, for a sample of 407 women, were analyzed, through the thermoluminescent dosimetry, radiation doses in the surface of skin and glandular absorbed doses for cranio-caudal view. The results show the presence of a large dose range to the same mammographic procedure, which, analyzed enclosed with 585 facilities, suggest be necessary the standardization of the mammographic technique. From that results, with the additive model, the excess of breast cancer (radioinduced) and lifetime loss risk, for age groups between 30 and 70 years were estimated. Is demonstrated that the benefits from dedicated mammography, overcome the relationship among the epidemiological aspects of breast cancer and ionizing radiation as an harmful agent, which may show an important correlation for large exposed populations, point out the importance of the continuous risk and benefit evaluation to the new technologies introduced. (author). 86 refs., 40 figs., 14 tabs

  4. Preliminary study of human breast tissue using synchrotron radiation combining WAXS and SAXS techniques

    International Nuclear Information System (INIS)

    Conceicao, A.L.C.; Antoniassi, M.; Poletti, M.E.; Caldas, L.V.E.

    2010-01-01

    Using synchrotron radiation, we combined simultaneously wide angle X-ray scattering (WAXS) and small angle X-ray scattering (SAXS) techniques to obtain the scattering profiles of normal and neoplastic breast tissues samples at the momentum transfer range 6.28 nm -1 ≤Q(=4π.sin(θ/2)/λ)≤50.26 nm -1 and 0.15 nm -1 ≤Q≤1.90 nm -1 , respectively. The results obtained show considerable differences between the scattering profiles of these tissues. We verified that the combination of some parameters (ratio between glandular and adipose peak intensity and third-order axial peak intensity) extracted from scattering profiles can be used for identifying breast cancer.

  5. 31P MRSI and 1H MRS at 7 T: initial results in human breast cancer.

    Science.gov (United States)

    Klomp, Dennis W J; van de Bank, Bart L; Raaijmakers, Alexander; Korteweg, Mies A; Possanzini, Cecilia; Boer, Vincent O; van de Berg, Cornelius A T; van de Bosch, Maurice A A J; Luijten, Peter R

    2011-12-01

    This study demonstrates the feasibility of the noninvasive determination of important biomarkers of human (breast) tumor metabolism using high-field (7-T) MRI and MRS. (31) P MRSI at this field strength was used to provide a direct method for the in vivo detection and quantification of endogenous biomarkers. These encompass phospholipid metabolism, phosphate energy metabolism and intracellular pH. A double-tuned, dual-element transceiver was designed with focused radiofrequency fields for unilateral breast imaging and spectroscopy tuned for optimized sensitivity at 7 T. T(1) -weighted three-dimensional MRI and (1) H MRS were applied for the localization and quantification of total choline compounds. (31) P MRSI was obtained within 20 min per subject and mapped in three dimensions over the breast with pixel volumes of 10 mL. The feasibility of monitoring in vivo metabolism was demonstrated in two patients with breast cancer during neoadjuvant chemotherapy, validated by ex vivo high-resolution magic angle spinning NMR and compared with data from an age-matched healthy volunteer. Concentrations of total choline down to 0.4 mM could be detected in the human breast in vivo. Levels of adenosine and other nucleoside triphosphates, inorganic phosphate, phosphocholine, phosphoethanolamine and their glycerol diesters detected in glandular tissue, as well as in tumor, were mapped over the entire breast. Altered levels of these compounds were observed in patients compared with an age-matched healthy volunteer; modulation of these levels occurred in breast tumors during neoadjuvant chemotherapy. To our knowledge, this is the first comprehensive MRI and MRS study in patients with breast cancer, which reveals detailed information on the morphology and phospholipid metabolism from volumes as small as 10 mL. This endogenous metabolic information may provide a new method for the noninvasive assessment of prognostic and predictive biomarkers in breast cancer treatment. Copyright

  6. Investigation on 3D dose distribution in digital breast tomosynthesis

    Science.gov (United States)

    Masi, M.

    2017-03-01

    Monte Carlo calculations for dosimetry in digital breast tomosynthesis (DBT) require experimental validations. We measured the 3D dose distribution in a breast phantom in a DBT scan, using XR-QA2 radiochromic films. We positioned film pieces at the entrance surface, at the bottom surface and at four depths between adjacent slabs in the 5-slabs, 5-cm-thick phantom simulating a compressed breast with 50% glandular fraction. We irradiated the phantom at 40kV (half value layer 1.1mm Al) for three angular tilting of the beam central axis ( {±}25° and 0° normal incidence). We determined the transverse and longitudinal distributions of the average dose in the phantom (in terms of air kerma normalized to the entrance air kerma), showing the angular dependence of the depth-resolved 3D dose distributions. In transverse planes the maximum dose variations were between 5.0% and 14.8% for normal incidence, and by 8.6% from the central to the tilted view. In the direction of the beam axis, the dose decreases up to about 71% from the entrance to the exit value. The extimated backscatter fraction was between 3% and 8%.

  7. Nipple adenoma arising from axillary accessory breast: a case report

    Directory of Open Access Journals (Sweden)

    Shioi Yoshihiro

    2012-11-01

    Full Text Available Abstract Nipple adenoma is a relatively rare benign breast neoplasm, and cases of the disease arising from the axillary accessory breast have very seldom been reported in the English literature. We report a case of nipple adenoma arising from axillary accessory breast including clinical and pathological findings. An 82-year-old woman presented with the complaint of a small painful mass in the right axilla. Physical examination confirmed a well-defined eczematous crusted mass that was 8 mm in size. The diagnosis of nipple adenoma was made from an excisional specimen on the basis of characteristic histological findings. Microscopic structural features included a compact proliferation of small tubules lined by epithelial and myoepithelial cells, and the merging of glandular epithelial cells of the adenoma into squamous epithelial cells in the superficial epidermal layer. Because clinically nipple adenoma may resemble Paget’s disease and pathologically can be misinterpreted as tubular carcinoma, the correct identification of nipple adenoma is an important factor in the differential diagnosis for axillary tumor neoplasms. Virtual slides The virtual slide(s for this article can be found here: http://www.diagnosticpathology.diagnomx.eu/vs/1186821489769063

  8. PVAL breast phantom for dual energy calcification detection

    International Nuclear Information System (INIS)

    Koukou, V; Martini, N; Velissarakos, K; Gkremos, D; Michail, C; Kandarakis, I; Fountos, G; Fountzoula, C; Bakas, A

    2015-01-01

    Microcalcifications are the main indicator for breast cancer. Dual energy imaging can enhance the detectability of calcifications by suppressing the tissue background. Two digital images are obtained using two different spectra, for the low- and high-energy respectively, and a weighted subtracted image is produced. In this study, a dual energy method for the detection of the minimum breast microcalcification thickness was developed. The used integrated prototype system consisted of a modified tungsten anode X-ray tube combined with a high resolution CMOS sensor. The breast equivalent phantom used was an elastically compressible gel of polyvinyl alcohol (PVAL). Hydroxyapatite was used to simulate microcalcifications with thicknesses ranging from 50 to 500 μm. The custom made phantom was irradiated with 40kVp and 70kVp. Tungsten (W) anode spectra filtered with 100μm Cadmium and 1000pm Copper, for the low- and high-energy, respectively. Microcalcifications with thicknesses 300μm or higher can be detected with mean glandular dose (MGD) of 1.62mGy. (paper)

  9. Checkpoint inhibitors in breast cancer

    DEFF Research Database (Denmark)

    Polk, Anne; Svane, Inge-Marie; Andersson, Michael

    2018-01-01

    INTRODUCTION: An increasing number of compounds directed against immune checkpoints are currently under clinical development. In this review we summarize current research in breast cancer. MATERIAL AND METHODS: A computer-based literature search was carried out using PubMed and EMBASE; data...... reported at international meetings and clinicaltrials.gov were included as well. RESULTS: The obtained overall response rate of PD-1/PD-L1 monotherapy varied from 5 to 30% in heavily pretreated triple negative breast cancer (TNBC). The median duration of progression free survival and overall survival were...... and induce long standing anti-tumor immunity in a subgroup of breast cancer patients. However, the identification of predictive biomarkers is crucial for further development of this treatment modality....

  10. A unique case of a huge mixed squamous cell and glandular papilloma of non-endobronchial origin with a peripheral growth

    Directory of Open Access Journals (Sweden)

    Kei Yabuki

    Full Text Available We report a case of a huge solitary non-endobronchial pulmonary tumor in a 76-year-old male smoker. The tumor measured 11 × 10 × 8 cm. It was ill-defined, and it was located periphery of the right lower lobe with the subpleural cystic spaces. He underwent right lower lobectomy with mediastinal lymph node dissection and is free from tumor 30 months after surgery. Microscopically, it was composed of a proliferation of squamous and ciliated columnar epithelial cells with a few mucous cells. These cells were arranged in a papillary growth fashion extending along the fibrously thickened alveolar septa together with metaplastic bronchiolar and squamous epithelia displaying an usual interstitial pneumonia-pattern. Although the histologic features of the tumor were that of a mixed squamous cell and glandular papilloma (MSCGP, it was peripherally located and showed a lepidic growth, and it was much larger than previously reported MSCGPs. It is possible that the tumor developed in association with bronchial metaplasia in the periphery of the lung, and then extended along the surface of the reconstructed air spaces, which resulted in its unique histologic appearance. Further investigations of respiratory papilloma are needed to clarify the pathogenesis of these lesions. Keywords: Mixed squamous cell and glandular papilloma, Non-endobronchial, Cytology, Interstitial pneumonia, Pulmonary tumor

  11. Breast MRI scan

    Science.gov (United States)

    ... or breast ultrasound Evaluate for possible rupture of breast implants Find any cancer that remains after surgery or chemotherapy Show blood ... Mean Abnormal results may be due to: Breast cancer Cysts Leaking or ruptured breast implants Abnormal breast tissue that is not cancer Scar ...

  12. Breast Cancer Surgery

    Science.gov (United States)

    FACTS FOR LIFE Breast Cancer Surgery The goal of breast cancer surgery is to remove the whole tumor from the breast. Some lymph nodes ... might still be in the body. Types of breast cancer surgery There are two types of breast cancer ...

  13. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme

    Energy Technology Data Exchange (ETDEWEB)

    Timmermans, Lore; Hauwere, An de; Bacher, Klaus; Thierens, Hubert [Ghent University, Department of Basic Medical Sciences, QCC-Gent, Ghent (Belgium); Bosmans, Hilde; Lemmens, Kim; Steen, Andre van [University Hospitals Leuven, Department of Radiology, Leuven (Belgium); Bleyen, Luc; Mortier, Griet; Herck, Koen van [Ghent University, Centrum voor Preventie en Vroegtijdige Opsporing van Kanker, Ghent (Belgium); Limbergen, Erik van [Leuvens Universitair Centrum voor Kankerpreventie, Leuven (Belgium); Martens, Patrick [Vroegtijdige Opsporing van Borstklierkanker vzw, Bruges (Belgium)

    2014-08-15

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. (orig.)

  14. Impact of the digitalisation of mammography on performance parameters and breast dose in the Flemish Breast Cancer Screening Programme

    International Nuclear Information System (INIS)

    Timmermans, Lore; Hauwere, An de; Bacher, Klaus; Thierens, Hubert; Bosmans, Hilde; Lemmens, Kim; Steen, Andre van; Bleyen, Luc; Mortier, Griet; Herck, Koen van; Limbergen, Erik van; Martens, Patrick

    2014-01-01

    To investigate the impact of digitalisation on performance parameters and breast dose of the Flemish Breast Cancer Screening Programme. Both computed (CR) and direct radiography (DR) are compared with screen-film mammography (SFM). Data from 975,673 mammographic examinations were collected from units which underwent digitalisation from SFM to CR (41 units) or DR (72 units) in the period 2005-2011. Performance indicators were obtained by consulting the Screening Programme database. Phantom and patient dosimetry data were acquired from the physical technical quality assurance of the programme. Digitalisation induced no significant change in cancer detection rate (CDR), percentage of ductal carcinomas in situ and percentage of breast cancers smaller than 1 cm. A decrease in false-positive results and third readings was observed, which was a time-related observation. After digitalisation, positive predictive value (PPV) increased and recall rates decreased. Compared with SFM, an increase of 30 % in mean glandular dose (MGD) was found for CR, while a similar change in the opposite direction was found for DR. No major differences in performance parameters after digitalisation were found. Transition of SFM to CR resulted in a higher MGD and associated lower detection-over-induction ratio (DIR), while the change to DR induced an improvement of DIR. (orig.)

  15. Genetic polymorphisms in varied environments.

    Science.gov (United States)

    Powell, J R

    1971-12-03

    Thirteen experimenital populationis of Drosophila willistoni were maintained in cages, in some of which the environments were relatively constant and in others varied. After 45 weeks, the populations were assayed by gel electrophoresis for polymorphisms at 22 protein loci. The average heterozygosity per individual and the average unmber of alleles per locus were higher in populations maintained in heterogeneous environments than in populations in more constant enviroments.

  16. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    Directory of Open Access Journals (Sweden)

    Erik Vrabič

    2018-02-01

    Full Text Available Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohibited. Considering the psychological importance of the breast in modern society, the possibility of breast reconstruction for the woman about to undergo a mastectomy is a comforting alternative. We can perform breast reconstruction with autologous tissue (autologous reconstruction, with breast implants and combination of both methods. For autologous reconstruction we can use local tissue (local flaps, or tissue from distant parts of the body (free vascular tissue transfer. Tissue expansion must be performed first, in many cases of breast reconstructions with breast implants. Conclusions. Possibility of breast reconstruction made a big progress last 3 decades. Today we are able to reconstruct almost every defect of the breast and the entire breast. Breast reconstruction rise the quality of life for breast cancer patients. Breast reconstruction is a team work of experts from many medicine specialites. In Slovenia we can offer breast reconstruction for breast cancer patients in Ljubljana, where plastic surgeons from Clinical Department for Plastic Surgery and Burns cooperate with oncologic surgeons. Ten years ago a similar cooperation between plastic surgeons and surgeons of the Centre for Breast Diseases was established in Maribor.

  17. Breast pain

    Science.gov (United States)

    ... that reducing the amount of fat, caffeine, or chocolate in your diet helps reduce breast pain. Vitamin ... harmful, but most studies have not shown any benefit. Talk to your provider before starting any medicine or ... Louisiana State University Health Sciences Center-Shreveport, Shreveport, LA. Review provided by ...

  18. Breast Cancer

    Science.gov (United States)

    ... right away. He or she will do a physical exam. They will ask you about your health history and your family’s history of breast cancer. ... and Wellness Staying Healthy Healthy Living Travel Occupational Health First Aid and ... Pets and Animals myhealthfinder Food and Nutrition Healthy Food ...

  19. Breast lymphoma

    African Journals Online (AJOL)

    To fulfil the criteria for primary breast lymphoma, the following characteristics were reqUired: (I) technically adequate specimens; (iI) mammary tissue and lymphomatous infiltrate in close association; (iil) no evidence of concurrent widespread disease; and (iv) no previous. Haematology/Oncology Division, Department of ...

  20. Breast cancer

    CERN Multimedia

    2002-01-01

    "Cancer specialists will soon be able to compare mammograms with computerized images of breast cancer from across Europe, in a bid to improve diagnosis and treatment....The new project, known as MammoGrid, brings together computer and medical imaging experts, cancer specialists, radiologists and epidemiologists from Bristol, Oxford, Cambridge, France and Italy" (1 page).

  1. Radiation dosimetry in digital breast tomosynthesis: Report of AAPM Tomosynthesis Subcommittee Task Group 223

    Energy Technology Data Exchange (ETDEWEB)

    Sechopoulos, Ioannis, E-mail: isechop@emory.edu [Departments of Radiology and Imaging Sciences, Hematology and Medical Oncology and Winship Cancer Institute, Emory University, 1701 Uppergate Drive Northeast, Suite 5018, Atlanta, Georgia 30322 (United States); Sabol, John M. [GE Healthcare, Global Diagnostic X-Ray, Mailstop W-701, 3000 North Grandview Boulevard, Waukesha, Wisconsin 53188 (United States); Berglund, Johan [Research and Development, Philips Women' s Healthcare, Solna (Sweden); Bolch, Wesley E. [J. Crayton Pruitt Family Department of Biomedical Engineering, University of Florida, Gainesville, Florida 32611 (United States); Brateman, Libby [University of Florida, Gainesville, Florida 32611 (United States); Christodoulou, Emmanuel; Goodsitt, Mitchell [Department of Radiology, University of Michigan, 1500 East Medical Center Drive, Ann Arbor, Michigan 48109 (United States); Flynn, Michael [Department of Radiology, Henry Ford Health System, Radiology Research 2F, 1 Ford Place, Detroit, Michigan 48202 (United States); Geiser, William [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030-4009 (United States); Kyle Jones, A. [Department of Imaging Physics, The University of Texas MD Anderson Cancer Center, Houston, Texas 77030 (United States); Lo, Joseph Y.; Paul Segars, W. [Department of Radiology, Medical Physics Graduate Program, and Department of Biomedical Engineering, Carl E. Ravin Advanced Imaging Laboratories, Duke University, Durham, North Carolina 27705 (United States); Maidment, Andrew D. A. [Department of Radiology, Perelman School of Medicine at the University of Pennsylvania, Philadelphia, Pennsylvania 19104-4206 (United States); Nishino, Kazuyoshi [R and D X-ray Products Group, Shimadzu Corporation, Tokyo (Japan); Nosratieh, Anita [Biomedical Engineering Graduate Group, Department of Radiology, University of California, Davis, California 95817 (United States); and others

    2014-09-15

    The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation.

  2. Radiation dosimetry in digital breast tomosynthesis: Report of AAPM Tomosynthesis Subcommittee Task Group 223

    International Nuclear Information System (INIS)

    Sechopoulos, Ioannis; Sabol, John M.; Berglund, Johan; Bolch, Wesley E.; Brateman, Libby; Christodoulou, Emmanuel; Goodsitt, Mitchell; Flynn, Michael; Geiser, William; Kyle Jones, A.; Lo, Joseph Y.; Paul Segars, W.; Maidment, Andrew D. A.; Nishino, Kazuyoshi; Nosratieh, Anita

    2014-01-01

    The radiation dose involved in any medical imaging modality that uses ionizing radiation needs to be well understood by the medical physics and clinical community. This is especially true of screening modalities. Digital breast tomosynthesis (DBT) has recently been introduced into the clinic and is being used for screening for breast cancer in the general population. Therefore, it is important that the medical physics community have the required information to be able to understand, estimate, and communicate the radiation dose levels involved in breast tomosynthesis imaging. For this purpose, the American Association of Physicists in Medicine Task Group 223 on Dosimetry in Tomosynthesis Imaging has prepared this report that discusses dosimetry in breast imaging in general, and describes a methodology and provides the data necessary to estimate mean breast glandular dose from a tomosynthesis acquisition. In an effort to maximize familiarity with the procedures and data provided in this Report, the methodology to perform the dose estimation in DBT is based as much as possible on that used in mammography dose estimation

  3. Male Breast Cancer

    Science.gov (United States)

    Although breast cancer is much more common in women, men can get it too. It happens most often to men between ... 60 and 70. Breast lumps usually aren't cancer. However, most men with breast cancer have lumps. ...

  4. Breast biopsy -- stereotactic

    Science.gov (United States)

    ... org/-/media/ACR/Files/Practice-Parameters/stereo-breast.pdf . Updated 2016. Accessed March 14, 2017. Parker C, Umphrey H, Bland K. The role of stereotactic breast biopsy in the management of breast disease. In: Cameron ...

  5. Breast Cancer in Men

    Science.gov (United States)

    ... ultrasound or a breast MRI cannot rule out breast cancer then you will need a biopsy to confirm diagnosis. If diagnosed When first diagnosed with breast cancer, many men are in shock. After all, ...

  6. MRI of the Breast

    Science.gov (United States)

    ... in evaluating women at high risk for breast cancer. MRI can successfully image the dense breast tissue common in younger women, and it can successfully image breast implants. Both of these are difficult to image using ...

  7. Male Breast Cancer

    Science.gov (United States)

    ... types of breast cancer that can occur in men include Paget's disease of the nipple and inflammatory breast cancer. Inherited genes that increase breast cancer risk Some men inherit abnormal (mutated) genes from their parents that ...

  8. Plasmacytoma of the Breast

    African Journals Online (AJOL)

    GB

    2015-10-04

    Oct 4, 2015 ... The clinical diagnosis of a breast plasmacytoma is ... lead to a diagnosis of breast plasmacytoma (1-3). Bone marrow ... breast cancer cases present at an advanced stage, ... pelvic ultrasonography, were normal, Bence Jones.

  9. Breast Cancer Disparities

    Science.gov (United States)

    ... 2.65 MB] Read the MMWR Science Clips Breast Cancer Black Women Have Higher Death Rates from Breast ... of Page U.S. State Info Number of Additional Breast Cancer Deaths Among Black Women, By State SOURCE: National ...

  10. Identification of novel genetic markers of breast cancer survival

    NARCIS (Netherlands)

    Q. Guo (Qi); M.K. Schmidt (Marjanka); P. Kraft (Peter); S. Canisius (Sander); C. Chen (Constance); S. Khan (Sofia); J.P. Tyrer (Jonathan); M.K. Bolla (Manjeet); Q. Wang (Qing); J. Dennis (Joe); K. Michailidou (Kyriaki); M. Lush (Michael); S. Kar (Siddhartha); J. Beesley (Jonathan); A.M. Dunning (Alison); M. Shah (Mitul); K. Czene (Kamila); H. Darabi (Hatef); M. Eriksson (Mikael); D. Lambrechts (Diether); C. Weltens (Caroline); K. Leunen; S.E. Bojesen (Stig); B.G. Nordestgaard (Børge); S.F. Nielsen (Sune); H. Flyger (Henrik); J. Chang-Claude (Jenny); A. Rudolph (Anja); P. Seibold (Petra); D. Flesch-Janys (Dieter); C. Blomqvist (Carl); K. Aittomäki (Kristiina); R. Fagerholm (Rainer); T.A. Muranen (Taru); F.J. Couch (Fergus); J.E. Olson (Janet); C. Vachon (Celine); I.L. Andrulis (Irene); J.A. Knight (Julia); G. Glendon (Gord); A.-M. Mulligan (Anna-Marie); A. Broeks (Annegien); F.B.L. Hogervorst (Frans); C.A. Haiman (Christopher); B.E. Henderson (Brian); F.R. Schumacher (Fredrick); L. Le Marchand (Loic); J. Hopper (John); H. Tsimiklis (Helen); C. Apicella (Carmel); M.C. Southey (Melissa); A. Cox (Angela); S.S. Cross (Simon); M.W.R. Reed (Malcolm); G.G. Giles (Graham G.); R.L. Milne (Roger L.); C.A. McLean (Catriona Ann); R. Winqvist (Robert); K. Pykäs (Katri); A. Jukkola-Vuorinen (Arja); M. Grip (Mervi); M.J. Hooning (Maartje); A. Hollestelle (Antoinette); J.W.M. Martens (John W. M.); A.M.W. van den Ouweland (Ans); F. Marme (Federick); A. Schneeweiss (Andreas); R. Yang (Rongxi); B. Burwinkel (Barbara); J.D. Figueroa (Jonine); S.J. Chanock (Stephen); J. Lissowska (Jolanta); E.J. Sawyer (Elinor); I.P. Tomlinson (Ian); M. Kerin (Michael); N. Miller (Nicola); H. Brenner (Hermann); A.K. Dieffenbach (Aida Karina); V. Arndt (Volker); B. Holleczek (B.); A. Mannermaa (Arto); V. Kataja (Vesa); V-M. Kosma (Veli-Matti); J.M. Hartikainen (J.); J. Li (Jingmei); J.S. Brand (Judith S.); M.K. Humphreys (Manjeet); P. Devilee (Peter); R.A.E.M. Tollenaar (Rob); C.M. Seynaeve (Caroline); P. Radice (Paolo); P. Peterlongo (Paolo); B. Bonnani (Bernardo); P. Mariani (Paolo); P.A. Fasching (Peter); M.W. Beckmann (Matthias); R. Hein (Rebecca); A.B. Ekici (Arif); G. Chenevix-Trench (Georgia); R. Balleine (Rosemary); K.-A. Phillips (Kelly-Anne); J. Benítez (Javier); M.P. Zamora (Pilar); J.I. Arias Pérez (José Ignacio); P. Menéndez (Primitiva); A. Jakubowska (Anna); J. Lubinski (Jan); K. Jaworska-Bieniek (Katarzyna); K. Durda (Katarzyna); U. Hamann (Ute); M. Kabisch (Maria); H.U. Ulmer (Hans); T. Rud̈iger (Thomas); S. Margolin (Sara); V. Kristensen (Vessela); S. Nord (Silje); D.G. Evans (Gareth); J. Abraham (Jean); H. Earl (Helena); L. Hiller (Louise); J.A. Dunn (J.); S. Bowden (Sarah); C.D. Berg (Christine); D. Campa (Daniele); W.R. Diver (Ryan); S.M. Gapstur (Susan M.); M.M. Gaudet (Mia); S.E. Hankinson (Susan); R.N. Hoover (Robert); A. Hüsing (Anika); R. Kaaks (Rudolf); M.J. Machiela (Mitchell J.); W.C. Willett (Walter C.); M. Barrdahl (Myrto); F. Canzian (Federico); S.-F. Chin (Suet-Feung); C. Caldas (Carlos); D. Hunter (David); S. Lindstrom (Stephen); M. García-Closas (Montserrat); P. Hall (Per); D.F. Easton (Douglas); D. Eccles (Diana); N. Rahman (Nazneen); H. Nevanlinna (Heli); P.D.P. Pharoah (Paul)

    2015-01-01

    textabstractBackground: Survival after a diagnosis of breast cancer varies considerably between patients, and some of this variation may be because of germline genetic variation. We aimed to identify genetic markers associated with breast cancer-specific survival. Methods: We conducted a large

  11. Pseudomonal breast infection

    Science.gov (United States)

    Rastall, S; Catchpole, C; Bright-Thomas, R; Thrush, S

    2010-01-01

    Breast infection and breast sepsis secondary to Pseudomonas aeruginosa is uncommon. We report two cases of pseudomonal breast infection leading to septic shock and abscess formation in women with non-responding breast infection. The management of breast infection is broad-spectrum antibiotics and ultrasound with aspiration of any collection. To treat breast infection effectively, the causative organism must be isolated to enable appropriate antibiotic therapy. PMID:20412664

  12. Varying Constants, Gravitation and Cosmology

    Directory of Open Access Journals (Sweden)

    Jean-Philippe Uzan

    2011-03-01

    Full Text Available Fundamental constants are a cornerstone of our physical laws. Any constant varying in space and/or time would reflect the existence of an almost massless field that couples to matter. This will induce a violation of the universality of free fall. Thus, it is of utmost importance for our understanding of gravity and of the domain of validity of general relativity to test for their constancy. We detail the relations between the constants, the tests of the local position invariance and of the universality of free fall. We then review the main experimental and observational constraints that have been obtained from atomic clocks, the Oklo phenomenon, solar system observations, meteorite dating, quasar absorption spectra, stellar physics, pulsar timing, the cosmic microwave background and big bang nucleosynthesis. At each step we describe the basics of each system, its dependence with respect to the constants, the known systematic effects and the most recent constraints that have been obtained. We then describe the main theoretical frameworks in which the low-energy constants may actually be varying and we focus on the unification mechanisms and the relations between the variation of different constants. To finish, we discuss the more speculative possibility of understanding their numerical values and the apparent fine-tuning that they confront us with.

  13. Multicolor immunofluorescence reveals that p63- and/or K5-positive progenitor cells contribute to normal breast epithelium and usual ductal hyperplasia but not to low-grade intraepithelial neoplasia of the breast.

    Science.gov (United States)

    Boecker, Werner; Stenman, Göran; Schroeder, Tina; Schumacher, Udo; Loening, Thomas; Stahnke, Lisa; Löhnert, Catharina; Siering, Robert Michael; Kuper, Arthur; Samoilova, Vera; Tiemann, Markus; Korsching, Eberhard; Buchwalow, Igor

    2017-05-01

    We contend that knowledge about the cellular composition of normal breast epithelium is a prerequisite for understanding proliferative breast disease. Against this background, we used multicolor immunofluorescence to study normal breast epithelium and two types of intraepithelial proliferative breast lesion for expression of the p63, basal keratin K5, glandular keratin K8/18, SMA, ER-alpha, and Ki67. We studied eight normal breast epithelium samples, 12 cases of usual ductal hyperplasia, and 33 cases of low-grade intraepithelial neoplasia (9 flat epithelial atypia, 14 low-grade ductal carcinoma in situ and 10 cases of lobular neoplasia). Usual ductal hyperplasia showed striking similarity to normal luminal breast epithelium including p63+ and/or K5+ luminal progenitor cells and the full spectrum of luminal progeny cells. In normal breast epithelium and usual ductal hyperplasia, expression of ER-alpha was associated with lack of expression of the proliferation antigen Ki67. In contrast, we found in both types of low-grade intraepithelial neoplasia robust expression of keratin K8/18 and a positive association between ER-alpha and Ki67 expression. However, these lesions were consistently negative for p63 and/or K5. Our observational study supports the view that usual ductal hyperplasia and low-grade intraepithelial neoplasia are different entities rather than part of a spectrum of the same disease. We propose a new operational model of cell differentiation that may serve to better understand correlations between normal breast epithelium and proliferative breast diseases. From our data we conclude that p63+ and/or K5+ progenitor cells contribute to maintenance of normal epithelium and usual ductal hyperplasia, but not to low-grade intraepithelial neoplasia of the breast.

  14. Breast Reduction Surgery

    Science.gov (United States)

    ... considering breast reduction surgery, consult a board-certified plastic surgeon. It's important to understand what breast reduction surgery entails — including possible risks and complications — as ...

  15. Weighted approximation with varying weight

    CERN Document Server

    Totik, Vilmos

    1994-01-01

    A new construction is given for approximating a logarithmic potential by a discrete one. This yields a new approach to approximation with weighted polynomials of the form w"n"(" "= uppercase)P"n"(" "= uppercase). The new technique settles several open problems, and it leads to a simple proof for the strong asymptotics on some L p(uppercase) extremal problems on the real line with exponential weights, which, for the case p=2, are equivalent to power- type asymptotics for the leading coefficients of the corresponding orthogonal polynomials. The method is also modified toyield (in a sense) uniformly good approximation on the whole support. This allows one to deduce strong asymptotics in some L p(uppercase) extremal problems with varying weights. Applications are given, relating to fast decreasing polynomials, asymptotic behavior of orthogonal polynomials and multipoint Pade approximation. The approach is potential-theoretic, but the text is self-contained.

  16. Estrelas variáveis

    OpenAIRE

    Viana, Sérgio Manuel de Oliveira

    2001-01-01

    A observação do céu nocturno é uma prática que vem da Antiguidade. Desde então e durante muito tempo pensou-se que as estrelas mantinham o brilho constante. Assim foi até ao século XVI, quando David Fabricius observou uma estrela cujo brilho variava periodicamente. Dois séculos mais tarde, Jonh Goodricke descobriu uma segunda estrela e com o desenvolvimento de instrumentos de observação este conjunto foi muito alargado e hoje inclui o Sol.A variação do brilho das estrelas variáveis permite d...

  17. A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries.

    Science.gov (United States)

    Lazebnik, Mariya; McCartney, Leah; Popovic, Dijana; Watkins, Cynthia B; Lindstrom, Mary J; Harter, Josephine; Sewall, Sarah; Magliocco, Anthony; Booske, John H; Okoniewski, Michal; Hagness, Susan C

    2007-05-21

    The efficacy of emerging microwave breast cancer detection and treatment techniques will depend, in part, on the dielectric properties of normal breast tissue. However, knowledge of these properties at microwave frequencies has been limited due to gaps and discrepancies in previously reported small-scale studies. To address these issues, we experimentally characterized the wideband microwave-frequency dielectric properties of a large number of normal breast tissue samples obtained from breast reduction surgeries at the University of Wisconsin and University of Calgary hospitals. The dielectric spectroscopy measurements were conducted from 0.5 to 20 GHz using a precision open-ended coaxial probe. The tissue composition within the probe's sensing region was quantified in terms of percentages of adipose, fibroconnective and glandular tissues. We fit a one-pole Cole-Cole model to the complex permittivity data set obtained for each sample and determined median Cole-Cole parameters for three groups of normal breast tissues, categorized by adipose tissue content (0-30%, 31-84% and 85-100%). Our analysis of the dielectric properties data for 354 tissue samples reveals that there is a large variation in the dielectric properties of normal breast tissue due to substantial tissue heterogeneity. We observed no statistically significant difference between the within-patient and between-patient variability in the dielectric properties.

  18. A large-scale study of the ultrawideband microwave dielectric properties of normal breast tissue obtained from reduction surgeries

    International Nuclear Information System (INIS)

    Lazebnik, Mariya; McCartney, Leah; Popovic, Dijana; Watkins, Cynthia B; Lindstrom, Mary J; Harter, Josephine; Sewall, Sarah; Magliocco, Anthony; Booske, John H; Okoniewski, Michal; Hagness, Susan C

    2007-01-01

    The efficacy of emerging microwave breast cancer detection and treatment techniques will depend, in part, on the dielectric properties of normal breast tissue. However, knowledge of these properties at microwave frequencies has been limited due to gaps and discrepancies in previously reported small-scale studies. To address these issues, we experimentally characterized the wideband microwave-frequency dielectric properties of a large number of normal breast tissue samples obtained from breast reduction surgeries at University of Wisconsin and University of Calgary hospitals. The dielectric spectroscopy measurements were conducted from 0.5 to 20 GHz using a precision open-ended coaxial probe. The tissue composition within the probe's sensing region was quantified in terms of percentages of adipose, fibroconnective and glandular tissues. We fit a one-pole Cole-Cole model to the complex permittivity data set obtained for each sample and determined median Cole-Cole parameters for three groups of normal breast tissues, categorized by adipose tissue content (0-30%, 31-84% and 85-100%). Our analysis of the dielectric properties data for 354 tissue samples reveals that there is a large variation in the dielectric properties of normal breast tissue due to substantial tissue heterogeneity. We observed no statistically significant difference between the within-patient and between-patient variability in the dielectric properties

  19. Excess antibody immunoassays for rat glandular kallikreins. Measurement of kallikrein from different organs in the presence of cross-reacting antigens

    International Nuclear Information System (INIS)

    Johansen, L.; Oerstavik, T.B.; Holck, M.; Nustad, K.

    1983-01-01

    An immunoradiometric assay has previously been developed for measurement of rat glandular kallikrein. In the present paper, further studies on the specificity and sensitivity of the method are described. Problems of interference of immunologically cross-reacting antigens were overcome by proper preabsorption of the antibody. A method was thus established in which enzymatic activity of the immunoreactive kallikrein could be measured even in the presence of enzymes sharing immunological determinants and substrate specificity with kallikrein. Two variants of the immunoradiometric assay have been evaluated. A simplified version with simultaneous addition of all reagents gave results equal to those obtained in the original assay. A further modification with delayed addition of the solid-phase antibody, gave considerable improvement in assay sensitivity. (Auth.)

  20. Dosimetric Comparison in Breast Radiotherapy of 4 MV and 6 MV on Physical Chest Simulator

    Energy Technology Data Exchange (ETDEWEB)

    Donato da Silva, Sabrina; Passos Ribeiro Campos, Tarcisio [Nuclear Engineering Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Batista Nogueira, Luciana [Anatomy and Imaging Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Lima Souza Castro, Andre [Nuclear Engineering Department, Federal University of Minas Gerais, Belo Horizonte (Brazil); Institute of Radiation San Francisco, Belo Horizonte (Brazil); Alves de oliveira, Marcio; Galvao Dias, Humberto [Cancer Hospital in Uberlandia, Uberlandia (Brazil)

    2015-07-01

    According to the World Health Organization (2014) breast cancer is the main cause of death by cancer in women worldwide. The biggest challenge of radiotherapy in the treatment of cancer is to deposit the entire prescribed dose homogeneously in the breast, sparing the surrounding tissue. In this context, this paper aimed at evaluating and comparing internal dose distribution in the mammary gland based on experimental procedures submitted to two distinct energy spectra produced in breast cancer radiotherapy. The methodology consisted of reproducing opposite parallel fields used in the treatment of breast tumors in a chest phantom. This simulator with synthetic breast, composed of equivalent tissue material (TE), was previously developed by the NRI Research Group (UFMG). The computer tomography (CT) scan of the simulator was obtained antecedently. The radiotherapy planning systems (TPS) in the chest phantom were performed in the ECLIPSE system from Varian Medical Systems and CAT 3D system from MEVIS. The irradiations were reproduced in the Varian linear accelerator, model SL- 20 Precise, 6 MV energy and Varian linear accelerator, 4 MV Clinac 6x SN11 model. Calibrations of the absorbed dose versus optical density from radiochromic films were generated in order to obtain experimental dosimetric distribution at the films positioned within the glandular and skin equivalent tissues of the chest phantom. The spatial dose distribution showed equivalence with the TPS on measurement data performed in the 6 MV spectrum. The average dose found in radiochromic films placed on the skin ranged from 49 to 79%, and from 39 to 49% in the mammary areola, for the prescribed dose. Dosimetric comparisons between the spectra of 4 and 6 MV, keeping the constant geometry of the fields applied in the same phantom, will be presented showing their equivalence in breast radiotherapy, as well as the variations will be discussed. To sum up, the dose distribution has reached the value expected in

  1. Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: a postmortem study.

    Science.gov (United States)

    Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q; Ducote, Justin L; Su, Min-Ying; Molloi, Sabee

    2013-12-01

    Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left-right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson's r, was used to evaluate the two image segmentation algorithms and the effect of bias field. The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left-right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left-right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson's r increased from 0.86 to 0.92 with the bias field correction. The investigated CLIC method

  2. Breast density quantification using magnetic resonance imaging (MRI) with bias field correction: A postmortem study

    International Nuclear Information System (INIS)

    Ding, Huanjun; Johnson, Travis; Lin, Muqing; Le, Huy Q.; Ducote, Justin L.; Su, Min-Ying; Molloi, Sabee

    2013-01-01

    Purpose: Quantification of breast density based on three-dimensional breast MRI may provide useful information for the early detection of breast cancer. However, the field inhomogeneity can severely challenge the computerized image segmentation process. In this work, the effect of the bias field in breast density quantification has been investigated with a postmortem study. Methods: T1-weighted images of 20 pairs of postmortem breasts were acquired on a 1.5 T breast MRI scanner. Two computer-assisted algorithms were used to quantify the volumetric breast density. First, standard fuzzy c-means (FCM) clustering was used on raw images with the bias field present. Then, the coherent local intensity clustering (CLIC) method estimated and corrected the bias field during the iterative tissue segmentation process. Finally, FCM clustering was performed on the bias-field-corrected images produced by CLIC method. The left–right correlation for breasts in the same pair was studied for both segmentation algorithms to evaluate the precision of the tissue classification. Finally, the breast densities measured with the three methods were compared to the gold standard tissue compositions obtained from chemical analysis. The linear correlation coefficient, Pearson'sr, was used to evaluate the two image segmentation algorithms and the effect of bias field. Results: The CLIC method successfully corrected the intensity inhomogeneity induced by the bias field. In left–right comparisons, the CLIC method significantly improved the slope and the correlation coefficient of the linear fitting for the glandular volume estimation. The left–right breast density correlation was also increased from 0.93 to 0.98. When compared with the percent fibroglandular volume (%FGV) from chemical analysis, results after bias field correction from both the CLIC the FCM algorithms showed improved linear correlation. As a result, the Pearson'sr increased from 0.86 to 0.92 with the bias field correction

  3. Usefulness of p16ink4a, ProEX C, and Ki-67 for the diagnosis of glandular dysplasia and adenocarcinoma of the cervix uteri.

    Science.gov (United States)

    Negri, Giovanni; Bellisano, Giulia; Carico, Elisabetta; Faa, Gavino; Kasal, Armin; Antoniazzi, Sonia; Egarter-Vigl, Eduard; Piccin, Andrea; Dalla Palma, Paolo; Vittadello, Fabio

    2011-07-01

    Although the diagnostic criteria of in-situ and invasive adenocarcinomas of the cervix uteri are well established, the differentiation from benign mimics may be difficult and the morphologic features of the precursors of endocervical adenocarcinoma are still debated. In this study, we evaluated the usefulness of p16ink4a (p16), ProEX C, and Ki-67 for the diagnosis of endocervical adenocarcinoma and its precursors. Immunohistochemistry with p16, ProEX C, and Ki-67 was performed in 82 glandular lesions including 15 invasive adenocarcinomas, 29 adenocarcinomas in situ (AIS), 22 non-neoplastic samples, and 16 cases of glandular dysplasia (GD), which showed significant nuclear abnormalities but did not meet the diagnostic criteria for AIS. The immunohistochemical expression pattern was scored according to the percentage of the stained cells (0, 1+, 2+, and 3+ when 0% to 5%, 6% to 25%, 26% to 50%, and more than 50% of the cells were stained, respectively) and was evaluated for each antibody. p16 was at least focally expressed (1+ or more) in 14 of 15 invasive adenocarcinomas, in all AIS and in 7 negative samples. ProEX C and Ki-67 both scored 1+ or more in all adenocarcinomas and AIS and in 8 and 6 negative samples, respectively. Of the GD 15, 14, and 15 expressed p16, ProEX C, and Ki-67, respectively. The score differences between neoplastic and non-neoplastic samples were highly significant for each marker (Pcervix uteri and may also improve the diagnostic accuracy of endocervical GD. In particularly problematic cases, the combination of p16 and a proliferation marker can provide additional help for the interpretation of these lesions.

  4. [Fibrocystic breast disease--breast cancer sequence].

    Science.gov (United States)

    Habor, V; Habor, A; Copotoiu, C; Panţîru, A

    2010-01-01

    Fibrocystic breast disease has developed a major issue: the breast cancer sequence. Its involvement regarding the increse of breast cancer risk has 2 aspects: it may be either the marker of a prone tissue or a premalignant hystological deffect. Difficult differential diagnosis of benign proliferative breast lession and carcinoma led to the idea of sequency between the two: cancer does not initiate on normal mammary epithelia; it takes several proliferative stages for it to occur. In our series we analized a number of 677 breast surgical procedures where the pathologic examination reveals 115 cases (17%) of coexistence between cancer and fibrocystic breast disease. This aspect has proved to be related to earlier debut of breast cancer, suggesting that epithelial hyperplasia is a risk factor for breast cancer.

  5. Plasminogen-independent initiation of the pro-urokinase activation cascade in vivo. Activation of pro-urokinase by glandular kallikrein (mGK-6) in plasminogen-deficient mice

    DEFF Research Database (Denmark)

    List, K; Jensen, Ole Nørregaard; Bugge, T H

    2000-01-01

    )-antitrypsin. We suggest that mouse glandular kallikrein mGK-6 is an activator of pro-uPA in the mouse urinary tract in vivo. Since this kallikrein is expressed in a number of tissues and also occurs in plasma, it can also be considered a candidate for a physiological pro-uPA activator in other locations....

  6. Diagnosis of breast cancer using diffuse optical spectroscopy from 500 to 1600 nm: comparison of classification methods

    Science.gov (United States)

    Nachabé, Rami; Evers, Daniel J.; Hendriks, Benno H. W.; Lucassen, Gerald W.; van der Voort, Marjolein; Rutgers, Emiel J.; Peeters, Marie-Jeanne Vrancken; van der Hage, Jos A.; Oldenburg, Hester S.; Wesseling, Jelle; Ruers, Theo J. M.

    2011-08-01

    We report on the use of diffuse optical spectroscopy analysis of breast spectra acquired in the wavelength range from 500 to 1600 nm with a fiber optic probe. A total of 102 ex vivo samples of five different breast tissue types, namely adipose, glandular, fibroadenoma, invasive carcinoma, and ductal carcinoma in situ from 52 patients were measured. A model deriving from the diffusion theory was applied to the measured spectra in order to extract clinically relevant parameters such as blood, water, lipid, and collagen volume fractions, β-carotene concentration, average vessels radius, reduced scattering amplitude, Mie slope, and Mie-to-total scattering fraction. Based on a classification and regression tree algorithm applied to the derived parameters, a sensitivity-specificity of 98%-99%, 84%-95%, 81%-98%, 91%-95%, and 83%-99% were obtained for discrimination of adipose, glandular, fibroadenoma, invasive carcinoma, and ductal carcinoma in situ, respectively; and a multiple classes overall diagnostic performance of 94%. Sensitivity-specificity values obtained for discriminating malignant from nonmalignant tissue were compared to existing reported studies by applying the different classification methods that were used in each of these studies. Furthermore, in these reported studies, either lipid or β-carotene was considered as adipose tissue precursors. We estimate both chromophore concentrations and demonstrate that lipid is a better discriminator for adipose tissue than β-carotene.

  7. Imaging lobular breast carcinoma: comparison of synchrotron radiation DEI-CT technique with clinical CT, mammography and histology

    Science.gov (United States)

    Fiedler, S.; Bravin, A.; Keyriläinen, J.; Fernández, M.; Suortti, P.; Thomlinson, W.; Tenhunen, M.; Virkkunen, P.; Karjalainen-Lindsberg, M.-L.

    2004-01-01

    Different modalities for imaging cancer-bearing breast tissue samples are described and compared. The images include clinical mammograms and computed tomography (CT) images, CT images with partly coherent synchrotron radiation (SR), and CT and radiography images taken with SR using the diffraction enhanced imaging (DEI) method. The images are evaluated by a radiologist and compared with histopathological examination of the samples. Two cases of lobular carcinoma are studied in detail. The indications of cancer are very weak or invisible in the conventional images, but the morphological changes due to invasion of cancer become pronounced in the images taken by the DEI method. The strands penetrating adipose tissue are seen clearly in the DEI-CT images, and the histopathology confirms that some strands contain the so-called 'Indian file' formations of cancer cells. The radiation dose is carefully measured for each of the imaging modalities. The mean glandular dose (MGD) for 50% glandular breast tissue is about 1 mGy in conventional mammography and less than 0.25 mGy in projection DEI, while in the clinical CT imaging the MGD is very high, about 45 mGy. The entrance dose of 95 mGy in DEI-CT imaging gives rise to an MGD of 40 mGy, but the dose may be reduced by an order of magnitude, because the contrast is very large in most images.

  8. Breast cancer in men

    Science.gov (United States)

    ... in situ - male; Intraductal carcinoma - male; Inflammatory breast cancer - male; Paget disease of the nipple - male; Breast cancer - male ... The cause of breast cancer in men is not clear. But there are risk factors that make breast cancer more likely in men: Exposure to ...

  9. Breast Cancer Overview

    Science.gov (United States)

    ... are here Home > Types of Cancer > Breast Cancer Breast Cancer This is Cancer.Net’s Guide to Breast Cancer. Use the menu below to choose the Overview/ ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer Introduction Statistics Medical Illustrations Risk Factors and Prevention ...

  10. Breast Cancer -- Male

    Science.gov (United States)

    ... Home > Types of Cancer > Breast Cancer in Men Breast Cancer in Men This is Cancer.Net’s Guide to Breast Cancer in Men. Use the menu below to choose ... social workers, and patient advocates. Cancer.Net Guide Breast Cancer in Men Introduction Statistics Risk Factors and Prevention ...

  11. Use of risk projection models to estimate mortality and incidence from radiation-induced breast cancer in screening programs

    International Nuclear Information System (INIS)

    Ramos, M; Ferrer, S; Villaescusa, J I; Verdu, G; Salas, M D; Cuevas, M D

    2005-01-01

    The authors report on a method to calculate radiological risks, applicable to breast screening programs and other controlled medical exposures to ionizing radiation. In particular, it has been applied to make a risk assessment in the Valencian Breast Cancer Early Detection Program (VBCEDP) in Spain. This method is based on a parametric approach, through Markov processes, of hazard functions for radio-induced breast cancer incidence and mortality, with mean glandular breast dose, attained age and age-at-exposure as covariates. Excess relative risk functions of breast cancer mortality have been obtained from two different case-control studies exposed to ionizing radiation, with different follow-up time: the Canadian Fluoroscopy Cohort Study (1950-1987) and the Life Span Study (1950-1985 and 1950-1990), whereas relative risk functions for incidence have been obtained from the Life Span Study (1958-1993), the Massachusetts tuberculosis cohorts (1926-1985 and 1970-1985), the New York post-partum mastitis patients (1930-1981) and the Swedish benign breast disease cohort (1958-1987). Relative risks from these cohorts have been transported to the target population undergoing screening in the Valencian Community, a region in Spain with about four and a half million inhabitants. The SCREENRISK software has been developed to estimate radiological detriments in breast screening. Some hypotheses corresponding to different screening conditions have been considered in order to estimate the total risk associated with a woman who takes part in all screening rounds. In the case of the VBCEDP, the total radio-induced risk probability for fatal breast cancer is in a range between [5 x 10 -6 , 6 x 10 -4 ] versus the natural rate of dying from breast cancer in the Valencian Community which is 9.2 x 10 -3 . The results show that these indicators could be included in quality control tests and could be adequate for making comparisons between several screening programs

  12. Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors: Automated measurement development for full field digital mammography

    International Nuclear Information System (INIS)

    Fowler, E. E.; Sellers, T. A.; Lu, B.; Heine, J. J.

    2013-01-01

    Purpose: The Breast Imaging Reporting and Data System (BI-RADS) breast composition descriptors are used for standardized mammographic reporting and are assessed visually. This reporting is clinically relevant because breast composition can impact mammographic sensitivity and is a breast cancer risk factor. New techniques are presented and evaluated for generating automated BI-RADS breast composition descriptors using both raw and calibrated full field digital mammography (FFDM) image data.Methods: A matched case-control dataset with FFDM images was used to develop three automated measures for the BI-RADS breast composition descriptors. Histograms of each calibrated mammogram in the percent glandular (pg) representation were processed to create the new BR pg measure. Two previously validated measures of breast density derived from calibrated and raw mammograms were converted to the new BR vc and BR vr measures, respectively. These three measures were compared with the radiologist-reported BI-RADS compositions assessments from the patient records. The authors used two optimization strategies with differential evolution to create these measures: method-1 used breast cancer status; and method-2 matched the reported BI-RADS descriptors. Weighted kappa (κ) analysis was used to assess the agreement between the new measures and the reported measures. Each measure's association with breast cancer was evaluated with odds ratios (ORs) adjusted for body mass index, breast area, and menopausal status. ORs were estimated as per unit increase with 95% confidence intervals.Results: The three BI-RADS measures generated by method-1 had κ between 0.25–0.34. These measures were significantly associated with breast cancer status in the adjusted models: (a) OR = 1.87 (1.34, 2.59) for BR pg ; (b) OR = 1.93 (1.36, 2.74) for BR vc ; and (c) OR = 1.37 (1.05, 1.80) for BR vr . The measures generated by method-2 had κ between 0.42–0.45. Two of these measures were significantly

  13. Primary breast tuberculosis: diagnostic and therapeutic dilemmas.

    Science.gov (United States)

    Hiremath, Bharati V; Subramaniam, Narayana

    2015-01-01

    To review the diagnostic and therapeutic challenges associated with treating isolated primary breast tuberculosis through discussion of our series of seven cases. Although breast is an uncommon site of occurrence of tuberculosis and isolated primary breast tuberculosis is an even rarer entity, its importance lies in distinguishing it from more common pathologies like abscesses or malignancy and avoiding unnecessary erroneous surgical intervention. The spectrum and presentation is wide and varied and we present our experience in managing seven such cases. A retrospective analysis of all the cases of histopathologically proven primary breast tuberculosis in the last three years at M.S. Ramaiah Hospital (2012-2014) was done. Analysis was in terms of mode of presentation, clinical features, diagnostic modalities used for evaluation and confirmation of the diagnosis, medical treatment and surgical intervention, if any. Special emphasis was placed on dilemmas in diagnosis and difficulties encountered during treatment. All cases were followed up till cure. Patients most commonly presented with a breast abscess, painful breast lumps and recurrent abscesses. Other foci of tuberculosis were ruled out in all of these patients. Majority were treated exclusively with anti-tubercular therapy (although regimens varied), but those with abscesses underwent incision and drainage. All cases were treated and followed up till cure. The challenges associated with primary breast tuberculosis are multiple, including which anti-tubercular therapy regimen to use, when to surgically intervene (as the breast is a cosmetically important area) and treating atypical mycobacteria. We provide a detailed discussion of the challenges we faced and review of literature.

  14. Breast cancer recurrence after reoperation for surgical bleeding

    DEFF Research Database (Denmark)

    Pedersen, Rikke Nørgaard; Bhaskaran, K; Heide-Jørgensen, U

    2017-01-01

    BACKGROUND: Bleeding activates platelets that can bind tumour cells, potentially promoting metastatic growth in patients with cancer. This study investigated whether reoperation for postoperative bleeding is associated with breast cancer recurrence. METHODS: Using the Danish Breast Cancer Group...... database and the Danish National Patient Register (DNPR), a cohort of women with incident stage I-III breast cancer, who underwent breast-conserving surgery or mastectomy during 1996-2008 was identified. Information on reoperation for bleeding within 14 days of the primary surgery was retrieved from.......i. 0·89 to 1·26). The estimates did not vary by site of breast cancer recurrence. CONCLUSION: In this large cohort study, there was no evidence of an association between reoperation for bleeding and breast cancer recurrence....

  15. Maintenance of prolactin receptors in human breast cancer

    International Nuclear Information System (INIS)

    Ben-David, M.; Dror, Y.; Biran, S.

    1981-01-01

    Breast tissue specimens of 110 women with various stages of breast cancer were tested in vitro to determine their specific binding sites for human prolactin. In contrast to the case of steroid receptors, binding sites for prolactin were found in the vast majority of breast cancer tissue. Distribution profiles giving amount of prolactin receptor and their affinity coefficients were found to be similar in the tissues of women whose ages, hormonal status, or stage of breast cancer varied. These findings show that in contrast to steroid receptors, human breast cancer tissue maintains binding sites for prolactin. The findings also indicate that there may be a higher dependency of breast cancer on prolactin than on steroids. Clinical trials must be carried out to determine the role of ''positive'' prolactin receptors in prognosis and prediction of response to future hormone therapy. (author)

  16. (Re) Imaging the breast: An analysis of a cultural obsession

    International Nuclear Information System (INIS)

    Domshy, H.C.

    2003-01-01

    This article is a brief resume of the work done for an academic thesis to explore any possible relationship between historical images of the female breast, and the subsequent development of positive or negative self-imaging for modern women. Using historical images of the breast from pre-Christian times to the pre ent, the many uses of breast imaging are explored. The research was conducted by the use of eleven interviews, as well as survey forms that targeted two different groups of women. One survey was given to the general female population, and the other targeted mammographic technologists. The findings were varied and provided an interesting examination of the ambiguity inherent in women's perception of their breasts and the breasts of other women. The research clearly indicated a need for farther study involving mammographic technologists. Radiographers combine the requirements of the job with their personal viewpoints, which have been impacted by both past and present breast imaging. (author)

  17. Digital Image Processing Technique for Breast Cancer Detection

    Science.gov (United States)

    Guzmán-Cabrera, R.; Guzmán-Sepúlveda, J. R.; Torres-Cisneros, M.; May-Arrioja, D. A.; Ruiz-Pinales, J.; Ibarra-Manzano, O. G.; Aviña-Cervantes, G.; Parada, A. González

    2013-09-01

    Breast cancer is the most common cause of death in women and the second leading cause of cancer deaths worldwide. Primary prevention in the early stages of the disease becomes complex as the causes remain almost unknown. However, some typical signatures of this disease, such as masses and microcalcifications appearing on mammograms, can be used to improve early diagnostic techniques, which is critical for women’s quality of life. X-ray mammography is the main test used for screening and early diagnosis, and its analysis and processing are the keys to improving breast cancer prognosis. As masses and benign glandular tissue typically appear with low contrast and often very blurred, several computer-aided diagnosis schemes have been developed to support radiologists and internists in their diagnosis. In this article, an approach is proposed to effectively analyze digital mammograms based on texture segmentation for the detection of early stage tumors. The proposed algorithm was tested over several images taken from the digital database for screening mammography for cancer research and diagnosis, and it was found to be absolutely suitable to distinguish masses and microcalcifications from the background tissue using morphological operators and then extract them through machine learning techniques and a clustering algorithm for intensity-based segmentation.

  18. Human Leukocyte Antigen (HLA) Genotype as a Contributor to Racial/Ethnic Differences in Breast Cancer: A Population-Based, Molecular Epidemiologic Study

    National Research Council Canada - National Science Library

    Glaser, Sally L

    2005-01-01

    ...; whether HLA genotype is related to breast cancer overall; whether associations and prevalence of associated HLA genotypes vary by race/ethnicity, and how much such differences explain racial/ethnic differences in breast cancer incidence...

  19. Characterization of optically stimulated luminescence for assessment of breast doses in mammography screening

    International Nuclear Information System (INIS)

    Alothmany, N.; Jiman, A.; Molla, N.I.; Natto, H.; Tayeb, M.; Nadwi, F.; Yusuf, M.; Alothmany, D.; Kinsara, A.A.; Saoudi, A.; Mail, N.; Khafaji, M.A.

    2016-01-01

    Landauer optically stimulated luminescence (OSL) technology nanoDot dosimeters (OSLDs) are characterized for use in mammography screening at various tube voltages, mAs values and target/filter combinations. The average glandular dose (AGD) for a 50-mm breast, based on the representative compressed breast thickness of a 45-mm polymethyl methacrylate (PMMA) phantom, is assessed using OSLDs with different beam conditions. Further, the linearity of the OSLD response is measured and angular dependence tests are performed for various tube potentials, mAs and target/filter combinations. The breast-absorbed doses are measured at various depths for a 32-kVp X-ray beam at 100 mAs, with a Mo/Rh target/filter combination. The measured incident air kerma values at different lateral positions exhibit a maximum deviation of 6%, and the average relative response of the OSLDs at the reference point (center) with respect to various lateral positions is found to be 1.001 ± 0.09%. The calculated AGD values are in the 1.3 ± 0.1-3.5 ± 0.2 mGy range, depending on the tube potential, tube loading and target/filter combinations. An exposure setup featuring the auto-exposure control (AEC) mode, 28 kVp, 73.8 mAs, and a Mo/Rh target/filter combination may be preferred for mammography screening for a compressed breast thickness of 45 mm. (authors)

  20. Persistent Postmastectomy Pain in Breast Cancer Survivors

    DEFF Research Database (Denmark)

    Belfer, Inna; Schreiber, Kristin L; Shaffer, John R

    2013-01-01

    , medical, and treatment information was abstracted from patients' medical records. One third (32.5%) of patients reported PPMP, defined as ≥3/10 pain severity in the breast, axilla, side, or arm, which did not vary according to time since surgery. Multiple regression analysis revealed significant...

  1. Lutein Supplementation Increases Breast Milk and Plasma Lutein Concentrations in Lactating Women and Infant Plasma Concentrations but Does Not Affect Other Carotenoids 1 2 3

    OpenAIRE

    Sherry, Christina L.; Oliver, Jeffery S.; Renzi, Lisa M.; Marriage, Barbara J.

    2014-01-01

    Lutein is a carotenoid that varies in breast milk depending on maternal intake. Data are lacking with regard to the effect of dietary lutein supplementation on breast milk lutein concentration during lactation and subsequent plasma lutein concentration in breast-fed infants. This study was conducted to determine the impact of lutein supplementation in the breast milk and plasma of lactating women and in the plasma of breast-fed infants 2–3 mo postpartum. Lutein is the dominant carotenoid in t...

  2. Breast Reconstruction with Flap Surgery

    Science.gov (United States)

    ... augmented with a breast implant to achieve the desired breast size. Surgical methods Autologous tissue breast reconstruction ... as long as a year or two before feeling completely healed and back to normal. Future breast ...

  3. Stages of Male Breast Cancer

    Science.gov (United States)

    ... Breast & Gynecologic Cancers Breast Cancer Screening Research Male Breast Cancer Treatment (PDQ®)–Patient Version General Information about Male Breast Cancer Go to Health Professional Version Key Points Male ...

  4. Breast development and anatomy.

    Science.gov (United States)

    Pandya, Sonali; Moore, Richard G

    2011-03-01

    In this article, the development of the female breast, as well as the functional anatomy, blood supply, innervation and lymphatic drainage are described. A thorough understanding of the breast anatomy is an important adjunct to a meticulous clinical breast examination. Breast examination is a complex skill involving key maneuvers, including careful inspection and palpation. Clinical breast examination can provide an opportunity for the clinician to educate patients about their breast and about breast cancer, its symptoms, risk factors, early detection, and normal breast composition, and specifically variability. Clinical breast examination can help to detect some cancers not found by mammography, and clinicians should not override their examination findings if imaging is not supportive of the physical findings.

  5. Breast metastases from rectal carcinoma

    Institute of Scientific and Technical Information of China (English)

    LI Jia; FANG Yu; LI Ang; LI Fei

    2011-01-01

    Metastases to the breast from extramammary neoplasms are very rare, constituting 2.7% of all malignant breast tumours. The most common primary tumor metastatic to the breast is primary breast cancer. Rectal cancer metastasizing to the breast is extremely rare. We report a case of aggressive rectal carcinoma with metastasis to the breast.

  6. Benefit-to-harm ratio of the Danish breast cancer screening programme

    DEFF Research Database (Denmark)

    Beau, Anna-Belle; Lynge, Elsebeth; Njor, Sisse Helle

    2017-01-01

    cancer deaths prevented divided by the number of overdiagnosed breast cancer cases, varied considerably. The objective of the study was to estimate the benefit-to-harm ratio of breast cancer screening in Denmark. The numbers of breast cancer deaths prevented and overdiagnosed cases [invasive and ductal...... to age 69 and followed until age 79, we estimated that 5.4 breast cancer deaths would be prevented and 2.1 cases overdiagnosed, under the observed scenario in Denmark of a breast cancer mortality reduction of 23.4% and 2.3% of the breast cancer cases being overdiagnosed. The estimated benefit......-to-harm ratio was 2.6 for invited women and 2.5 for screened women. Hence, 2-3 women would be prevented from dying from breast cancer for every woman overdiagnosed with invasive breast cancer or DCIS. The difference between the previous published ratios and 2.6 for Denmark is probably more a reflection...

  7. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  8. The results of screening examinations of breast cancer conducted from 2004 to 2005 in Sierpc poviat

    International Nuclear Information System (INIS)

    Nowicki, A.; Milecka, A.

    2007-01-01

    Background: Breast cancer is one of the most common malignant neoplasms among women in Poland. 11733 new cases were registered in 2003. Well organized screening examinations are the most effective method of fighting against breast cancer. Aim of study: The main objective of this work was a preliminary analysis of a prophylactic examination programme for breast cancer in Sierpc district performed by the Independent Unit of Public Health Care Centres in Sierpc during the period of 2004 to 2005. Material and methods: The research was performed based on retrospective analysis of files obtained from the Department of Radiology of the Independent Unit of Public Health Care Centres in Sierpc. Prophylactic examination for detection of breast cancer includes physical examination of the breast as well as mammography. Results: The research includes 1291 women, most of them at age 50-55 years (57.1 years on average). City residents represent the biggest group of women. Nearly half of women had their first menstruation at the age of 14 to 15 years. The last menstruation occurred at age between 46 and 50 years old most frequently. The average number of labours was 2.3 and 2.5 during the analyzed period. The first labour occurred most frequently in women at the age of 21 to 25 years old. Most of the women never took previously and still do not take hormonal medicines. 80% of women have done breast self examination but over half of them (60.8%) did it occasionally. Breast examination done by a gynaecologist was performed in 22% of women during the last year. Breast cancer did not occur among family members in most of the analyzed women. Breast pain was the most frequent complaint. Over half of women (64.6%) previously underwent mammography. The biggest group among them (31.1%) includes women who had mammography between 2003 and 2004. Adipose glandular breast texture was detected in near half of women (43.5%). The result of mammography was normal in most analyzed women (87.1%). A

  9. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  10. Accelerated partial breast irradiation

    Institute of Scientific and Technical Information of China (English)

    2002-01-01

    @@ Whole breast radiotherapy afier tumor lumpectomy is based on the premise that that the breast cancer recurrence rate is reduced through the elimination of residual cancer foci in the remaining tissue immediately adjacent to the lumpectomy site and occult multicentric areas of in situ or infiltrating cancer in remote areas of the breast. The relevance of remote foci to ipsilateral breast failure rates after breast conserving treatment is debatable, because 65%~100% of recurrences develop in the same quadrant as the initial tumor. This has led several investigators to question whether radiotherapy must be administered to the entire breast.

  11. Breast cancer screening in Korean woman with dense breast tissue

    International Nuclear Information System (INIS)

    Shin, Hee Jung; Ko, Eun Sook; Yi, Ann

    2015-01-01

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results

  12. Breast cancer screening in Korean woman with dense breast tissue

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Hee Jung [Dept. of Radiology and Research Institute of Radiology, University of Ulsan College of Medicine, Asan Medical Center, Seoul (Korea, Republic of); Ko, Eun Sook [Dept. of Radiology, Sungkyunkwan University School of Medicine, Samsung Medical Center, Seoul (Korea, Republic of); Yi, Ann [Dept. of Radiology, Seoul National University College of Medicine, Seoul National University Hospital, Seoul (Korea, Republic of)

    2015-11-15

    Asian women, including Korean, have a relatively higher incidence of dense breast tissue, compared with western women. Dense breast tissue has a lower sensitivity for the detection of breast cancer and a higher relative risk for breast cancer, compared with fatty breast tissue. Thus, there were limitations in the mammographic screening for women with dense breast tissue, and many studies for the supplemental screening methods. This review included appropriate screening methods for Korean women with dense breasts. We also reviewed the application and limitation of supplemental screening methods, including breast ultrasound, digital breast tomosynthesis, and breast magnetic resonance imaging; and furthermore investigated the guidelines, as well as the study results.

  13. Breast cysts in adolescents - diagnostics, monitoring, treatment

    Energy Technology Data Exchange (ETDEWEB)

    Jakubowska, A; Brzewski, M [Department of Paediatric Radiology of the Medical University of Warsaw, Warsaw (Poland); Grajewska-Ferens, M [Department of Paediatrics and Endocrinology of the Medical University of Warsaw, Warsaw (Poland)

    2011-07-01

    Background: The aim of the paper was the US evaluation of hormonal disorders and treatment results in adolescent girls and boys with breast cysts. Material/Methods: In the years 2001 - 2009, US examination of the breast was performed in 427 children aged 10 - 18 years, with clinically suspected breast pathologies. The indications for US examination typically included pain, breast swelling and a palpable tumor. The US examination was performed using a 7 - 12 MHz linear transducer. Results: Breast cysts were found in 42 children: 36 adolescent girls and 6 boys with gynaecomastia. Infected cysts were found in 35 children. The cysts ranged in size from 5 mm to 30 mm. In 5 of the girls, large cysts were treated by an incision and drainage, and in all the children with infected cysts, antibiotic therapy was used. Hormonal disorders were found in 30 girls. A follow-up examination was performed, and the observation time varied from 1/12 to 2 years. The cysts disappeared completely in 30 children. Hormonal therapy was introduced in 5 girls. Conclusions: Breast cysts found in US examinations are indications for check-up examinations including endocrinological diagnostics and, if the cyst is persistent, possibly for hormonal treatment. (authors)

  14. Nonpalpable breast cancer : mammographic and clinical findings

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan [Yonsei Univ. College of Medicine, Seoul (Korea, Republic of)

    1998-08-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group.

  15. Nonpalpable breast cancer : mammographic and clinical findings

    International Nuclear Information System (INIS)

    Seo, Jae Seung; Kim, Eun Kyung; Oh, Ki Keun; Cheon, Young Jik; Lee, Byung Chan

    1998-01-01

    To evaluate the mammographic and clinical findings of nonpalpable breast cancer. Materials and Methods : In 28 of 607 breast cancer patients examined between January 1994 and April 1997, lesions were nonpalpable. We retrospectively analyzed the mammographic, clinical and pathologic features of 25 patients (28 lesions) whose mammograms we obtained. Results : Among these 25 patients (28 lesions) screening was abnormal in 22; other symptoms were bloody nipple discharge(n=4), and nipple eczema(n=2). The patients were 34-62 (mean 52)years old. Invasive ductal carcinoma(n=13), DCIS(ductal carcinoma in situ, n-12), Paget's disease (n=2), and LCIS(lobular carcinoma in situ, n=1) were found during surgery. Six of 28 lesions(21%) showed evidence of axillary nodal metastasis;the majority arose from the upper outer quadrant of the breast (n=21). The mammographic findings were mass (50%), (and mass with microcalcification, 11%); microcalcification(29%); asymmetrical density(14%); and normal (7%). According to the mammographic density of breast parenchyma, the major finding in the low density group(N1+P1) was mass(9/9), and in the high density group(P2+DY) was microcalcification (12/19). Conclusion : The most common mammographic findings of nonpalpable breast cancer were mass (50%) and microcalcification(29%). Its features varied according to the mammographic density of breast parenchyma;mass was the main finding in the low density group and microcalcification in the high density group

  16. MODERN VIEWS ON BILATERAL BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Ye. A. Fesik

    2014-01-01

    Full Text Available Presented modern literature data on the features of the pathogenesis, course, clinical and morphological expression and tumor characteristics, parameters and nodal metastasis of hematogenous bilateral breast cancer. Highlight the results of domestic and foreign studies in recent years to determine the prognostic factors and recurrence of synchronous and metachronous bilateral breast cancer. It was revealed that the frequency of bilateral breast tumor lesions varies widely, ranging from 0.1 to 20%, with metachronous tumors recorded significantly higher (69.6% than the synchronous (22.7%. The probability of occurrence of metachronous breast cancer is higher in women with a family history, as well as if they have a gene mutation BRCA-1. Found that the most common histological type of breast tumor with bilateral lesions is invasive ductal. However, the incidence of invasive lobular cancer and non-invasive lobular cancer is slightly higher among synchronous bilateral cancer compared with unilateral disease. Studies have shown that in a double-sided synchronous breast cancer tumor, as a rule, has a lower degree of differentiation, and the higher the expression level of estrogen receptors and progesterone receptors. Relevance of the issue because the identification of patterns in the study of lymphatic and hematogenous features bilateral metastasis of mammary tumors provides a basis for speculation about the differences in the progression of neoplastic disease in these groups and is a cause for further detailed research in this area to identify and evaluate the prognosis and also the choice of tactics of such patients.

  17. Triple Test in Carcinoma Breast

    Science.gov (United States)

    Sameer; Mukherjee, Arindam

    2014-01-01

    Introduction: The commonest clinical presentation in majority of breast pathology is a lump. A definite diagnosis of breast lump is very important for the surgeon to decide on the final course of treatment and also saves the patient from unnecessary physical, emotional and psychological trauma if there is a definite preoperative diagnosis of benign lesion. The present study was done to evaluate the effectiveness and relevance of “TRIPLE TEST”in diagnosis of carcinoma breast in rural labour class population. Materials and Methods: The present study was a prospective study conducted on patients over 35 years of age having palpable breast lumps presenting in the out patient department of general surgery, ESI Hospital Basaidarapur New Delhi, India. The duration of study was from May 2007 to June 2009 and a total of 100 cases were studied. Each patient was subjected to a detailed history, clinical breast examination ,diagnostic mammography and FNAC. In this study, the results of each modality was divided in three groups: benign, suspicious and malignant. The sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of each test was calculated individually and as combined. Result: Out of 100 patients enrolled in this study, 60 cases were benign and 40 cases were of malignant breast disease. The age of patients with carcinoma breast in the series varied from 35 years to 70 years. The highest incidence of malignancy noted was 30% in 41-50 years age group (4th decade) followed by 27.5% in 51-60 years age group (5th decade). The sensitivity of clinical examination was found to be 75%, specificity was 83.3%, positive predictive value (PPV) of 75% and diagnostic accuracy of 80%. The sensitivity, specificity, positive predictive value and diagnostic accuracy of mammography was calculated and was found to be 94.9% , 90% , 86% and 92% respectively. The sensitivity, specificity, positive predictive value and diagnostic accuracy of

  18. Breast Abscess Mimicking Breast Carcinoma in Male.

    Science.gov (United States)

    Gochhait, Debasis; Dehuri, Priyadarshini; Umamahesweran, Sandyya; Kamat, Rohan

    2018-01-01

    Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  19. Breast Abscess Mimicking Breast Carcinoma in Male

    Directory of Open Access Journals (Sweden)

    Debasis Gochhait

    2018-01-01

    Full Text Available Male breast can show almost all pathological entities described in female breast. Inflammatory conditions of the breast in male are not common; however, occasionally, it can be encountered in the form of an abscess. Clinically, gynecomastia always presents as a symmetric unilateral or bilateral lump in the retroareolar region, and any irregular asymmetric lump raises a possibility of malignancy. Radiology should be used as a part of the triple assessment protocol for breast lump along with fine-needle aspiration cytology for definite diagnosis and proper management.

  20. BREAST RECONSTRUCTIONS AFTER BREAST CANCER TREATING

    OpenAIRE

    Erik Vrabič

    2018-01-01

    Background. Breasts are an important symbol of physical beauty, feminity, mothering and sexual desire through the entire history of mankind. Lost of the whole or part of the breast is functional and aesthetic disturbance for woman. It is understandable, that the woman, who is concerned over breast loss, is as appropriate as another person´s concern over the loss of a limb or other body part. Before the 1960, breast reconstruction was considered as a dangerous procedure and it was almost prohi...

  1. ED breast cases and other breast emergencies.

    Science.gov (United States)

    Khadem, Nasim; Reddy, Sravanthi; Lee, Sandy; Larsen, Linda; Walker, Daphne

    2016-02-01

    Patients with pathologic processes of the breast commonly present in the Emergency Department (ED). Familiarity with the imaging and management of the most common entities is essential for the radiologist. Additionally, it is important to understand the limitations of ED imaging and management in the acute setting and to recognize when referrals to a specialty breast center are necessary. The goal of this article is to review the clinical presentations, pathophysiology, imaging, and management of emergency breast cases and common breast pathology seen in the ED.

  2. Expression of podoplanin and TGF-beta in glandular odontogenic cyst and its comparison with developmental and inflammatory odontogenic cystic lesions.

    Science.gov (United States)

    Alaeddini, Mojgan; Eshghyar, Nosratollah; Etemad-Moghadam, Shahroo

    2017-01-01

    The number of studies investigating the immunohistochemical characteristics of glandular odontogenic cysts (GOCs) is limited, due to its rarity. TGF-beta has been suggested to induce podoplanin expression in some lesions. We aimed to evaluate and compare podoplanin and TGF-beta expression in GOC and other odontogenic cystic lesions. A total of 43 samples including five GOCs, 10 dentigerous cysts (DCs), eight unicystic ameloblastoma (UAs), and 20 radicular cysts (RCs) were selected and subjected to immunohistochemical staining using monoclonal antibodies against podoplanin and TGF-beta. Kruskal-Wallis test and Mann-Whitney U-test were used for statistical analysis along with Bonferroni for adjusting P-values (P < 0.05). Podoplanin immunoreactivity was observed in 80%, 70%, and 100% of DCs, RCs, and UAs, respectively, while none of the GOCs were positive for this marker (P = 0.004). Significant differences were only found in the GOC specimens. TGF-beta positivity occurred in the capsule and epithelium of all GOCs and DCs, while RCs and UAs demonstrated different expression percentages in the capsular and epithelial tissues. Epithelial TGF-beta showed significant differences among the studied lesions (P = 0.007) with the main difference found between DCs with RCs and DCs with UAs. Lack of podoplanin expression might be involved in the characteristic histologic and behavioral features of GOC, which seems to be unrelated to TGF-beta expression. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  3. Development of an Expert System as a Diagnostic Support of Cervical Cancer in Atypical Glandular Cells, Based on Fuzzy Logics and Image Interpretation

    Directory of Open Access Journals (Sweden)

    Karem R. Domínguez Hernández

    2013-01-01

    Full Text Available Cervical cancer is the second largest cause of death among women worldwide. Nowadays, this disease is preventable and curable at low cost and low risk when an accurate diagnosis is done in due time, since it is the neoplasm with the highest prevention potential. This work describes the development of an expert system able to provide a diagnosis to cervical neoplasia (CN precursor injuries through the integration of fuzzy logics and image interpretation techniques. The key contribution of this research focuses on atypical cases, specifically on atypical glandular cells (AGC. The expert system consists of 3 phases: (1 risk diagnosis which consists of the interpretation of a patient’s clinical background and the risks for contracting CN according to specialists; (2 cytology images detection which consists of image interpretation (IM and the Bethesda system for cytology interpretation, and (3 determination of cancer precursor injuries which consists of in retrieving the information from the prior phases and integrating the expert system by means of a fuzzy logics (FL model. During the validation stage of the system, 21 already diagnosed cases were tested with a positive correlation in which 100% effectiveness was obtained. The main contribution of this work relies on the reduction of false positives and false negatives by providing a more accurate diagnosis for CN.

  4. A varying-α brane world cosmology

    International Nuclear Information System (INIS)

    Youm, Donam

    2001-08-01

    We study the brane world cosmology in the RS2 model where the electric charge varies with time in the manner described by the varying fine-structure constant theory of Bekenstein. We map such varying electric charge cosmology to the dual variable-speed-of-light cosmology by changing system of units. We comment on cosmological implications for such cosmological models. (author)

  5. Optical Imaging of the Breast

    International Nuclear Information System (INIS)

    Kim, Min Jung; Kim, Eun Kyung

    2011-01-01

    As the increased prevalence of breast cancer and the advances in breast evaluation awareness have resulted in an increased number of breast examinations and benign breast biopsies, several investigations have been performed to improve the diagnostic accuracy for breast lesions. Optical imaging of the breast that uses nearinfrared light to assess the optical properties of breast tissue is a novel non-invasive imaging technique to characterize breast lesions in clinical practice. This review provides a summary of the current state of optical breast imaging and it describes the basic concepts of optical imaging, the potential clinical applications for breast cancer imaging and its potential incorporation with other imaging modalities

  6. Living Beyond Breast Cancer

    Science.gov (United States)

    ... ACTH CAF CMF FAC TAC TC TCH TH THP Radiation Therapy Whole Breast Radiation Partial Breast Radiation ... Basics Treatments and Your Bone Health Bone Health Tests Improving Bone Health Medicines To Protect Bones Diet, ...

  7. Breast cancer imaging

    International Nuclear Information System (INIS)

    Funke, M.; Villena, C.

    2008-01-01

    Advances in female breast imaging have substantially influenced the diagnosis, therapy, and prognosis of breast cancer in the past few years. Mammography using conventional or digital technique is considered the gold standard for the early detection of breast cancer. Other modalities such as breast ultrasound and contrast-enhanced magnetic resonance imaging of the breast play an important role in diagnostic imaging, staging, and follow-up of breast cancer. Percutaneous needle biopsy is a faster, less invasive, and more cost-effective method than surgical biopsy for verifying the histological diagnosis. New methods such as breast tomosynthesis, contrast-enhanced mammography, and positron emission tomography promise to further improve breast imaging. Further studies are mandatory to adapt these new methods to clinical needs and to evaluate their performance in clinical practice. (orig.) [de

  8. Inflammatory Breast Cancer

    Science.gov (United States)

    ... Common Cancer Types Recurrent Cancer Common Cancer Types Bladder Cancer Breast Cancer Colorectal Cancer Kidney (Renal Cell) Cancer ... white women. Inflammatory breast tumors are frequently hormone receptor negative, which means they cannot be treated with ...

  9. Cosmetic breast surgery - discharge

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000273.htm Cosmetic breast surgery - discharge To use the sharing features on this page, please enable JavaScript. You had cosmetic breast surgery to change the size or shape ...

  10. Breast cancer staging

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/patientinstructions/000911.htm Breast cancer staging To use the sharing features on this ... Once your health care team knows you have breast cancer , they will do more tests to stage it. ...

  11. Design and validation of realistic breast models for use in multiple alternative forced choice virtual clinical trials.

    Science.gov (United States)

    Elangovan, Premkumar; Mackenzie, Alistair; Dance, David R; Young, Kenneth C; Cooke, Victoria; Wilkinson, Louise; Given-Wilson, Rosalind M; Wallis, Matthew G; Wells, Kevin

    2017-04-07

    A novel method has been developed for generating quasi-realistic voxel phantoms which simulate the compressed breast in mammography and digital breast tomosynthesis (DBT). The models are suitable for use in virtual clinical trials requiring realistic anatomy which use the multiple alternative forced choice (AFC) paradigm and patches from the complete breast image. The breast models are produced by extracting features of breast tissue components from DBT clinical images including skin, adipose and fibro-glandular tissue, blood vessels and Cooper's ligaments. A range of different breast models can then be generated by combining these components. Visual realism was validated using a receiver operating characteristic (ROC) study of patches from simulated images calculated using the breast models and from real patient images. Quantitative analysis was undertaken using fractal dimension and power spectrum analysis. The average areas under the ROC curves for 2D and DBT images were 0.51  ±  0.06 and 0.54  ±  0.09 demonstrating that simulated and real images were statistically indistinguishable by expert breast readers (7 observers); errors represented as one standard error of the mean. The average fractal dimensions (2D, DBT) for real and simulated images were (2.72  ±  0.01, 2.75  ±  0.01) and (2.77  ±  0.03, 2.82  ±  0.04) respectively; errors represented as one standard error of the mean. Excellent agreement was found between power spectrum curves of real and simulated images, with average β values (2D, DBT) of (3.10  ±  0.17, 3.21  ±  0.11) and (3.01  ±  0.32, 3.19  ±  0.07) respectively; errors represented as one standard error of the mean. These results demonstrate that radiological images of these breast models realistically represent the complexity of real breast structures and can be used to simulate patches from mammograms and DBT images that are indistinguishable from

  12. Transsexual Mastectomy: Selection of Appropriate Technique According to Breast Characteristics

    Directory of Open Access Journals (Sweden)

    Hüsamettin Top

    2017-04-01

    Full Text Available Background: Subcutaneous mastectomy for female- to-male transsexuals is usually the first surgical pro- cedure in sexual reassignment. The main objective of subcutaneous mastectomy is to create an aesthetically pleasing male chest contour by removing all glandular tissue while minimizing chest wall scars. Aims: In this paper, we present our experience with subcutaneous mastectomy performed in female-to- male transsexual patients. The authors recommend their point of view to aid in selecting the most suitable subcutaneous mastectomy technique depending on breast characteristics. Study Design: Retrospective cross-sectional study. Methods: Between March 2011 and December 2014, 52 patients underwent bilateral subcutaneous mastec- tomies (total of 104 mastectomies, performed using the following four techniques: Webster semicircular, concentric circular, vertical, and apron flap. The tech- nique decision depended on the breast size, degree of skin excess, skin elasticity, chest width, nipple areolar complex size and position. Results: Seventeen patients (32.7% were operated with Webster semicircular, 7 patients (13.5% with con- centric periareolar, 12 patients with vertical (23%; and 16 patients (30.8% with the apron flap technique. The overall postoperative complication rate was 13.4%. All patients were satisfied with the aesthetic results of their subcutaneous mastectomies within the follow-up period. Conclusion: To obtain higher patient satisfaction with aesthetic results and lower postoperative complication rates, breast characteristics are evaluated in a detailed fashion, while choosing the ideal technique of Female-to-Male (FtM subcutaneous mastectomy. The presented surgical new algorithm facilitates the selection of the most reliable surgical technique

  13. Alternative Approach to Traumatic Stensen’s Duct Injuries Accompanied by Glandular Involvement: Botulinum Toxin Injection to the Gland in Conjunction with Microsurgical Repair of the Duct in an Acute Setting

    OpenAIRE

    Mert Çalış; Zeynep Öz; Hakan Uzun; Burçe Özgen; Alp Çetin3; Ali Emre Aksu

    2017-01-01

    Objective: The aim of this study was to evaluate the long-term results of a simultaneous application of botulinum toxin to the parotid gland in conjunction with the microsurgical repair of the duct in an acute setting and to encourage using botulinum toxin as a first-line option to prevent future complications associated with glandular involvement. Material and Methods: Three patients who were referred to the Plastic Surgery Clinic by the emergency room of the Hacettepe University Hospita...

  14. Influence of X-ray scatter radiation on image quality in Digital Breast Tomosynthesis (DBT)

    Science.gov (United States)

    Rodrigues, M. J.; Di Maria, S.; Baptista, M.; Belchior, A.; Afonso, J.; Venâncio, J.; Vaz, P.

    2017-11-01

    Digital breast tomosynthesis (DBT) is a quasi-three-dimensional imaging technique that was developed to solve the principal limitation of mammography, namely the overlapping tissue effect. This issue in standard mammography (SM) leads to two main problems: low sensitivity (difficulty to detect lesions) and low specificity (non-negligible percentage of false positives). Although DBT is now being introduced in clinical practice the features of this technique have not yet been fully and accurately assessed. Consequently, optimization studies in terms of choosing the most suitable parameters which maximize image quality according to the known limits of breast dosimetry are currently performing. In DBT, scatter radiation can lead to a loss of contrast and to an increase of image noise by reducing the signal-to-difference-noise ratio (SDNR) of a lesion. Moreover the use of an anti-scatter grid is a concern due to the low exposure of the photon flux available per projection. For this reason the main aim of this study was to analyze the influence of the scatter radiation on image quality and the dose delivered to the breast. In particular a detailed analysis of the scatter radiation on the optimal energy that maximizes the SDNR was performed for different monochromatic energies and voltages. To reach this objective the PenEasy Monte Carlo (MC) simulation tool imbedded in the general-purpose main program PENELOPE, was used. After a successful validation of the MC model with measurements, 2D projection images of primary, coherent and incoherent photons were obtained. For that, a homogeneous breast phantom (2, 4, 6, 8 cm) with 25%, 50% and 75% glandular compositions was used, including a 5 mm thick tumor. The images were generated for each monochromatic X-ray energies in the range from 16 keV to 32 keV. For each angular projection considered (25 angular projections covering an arc of 50°) the scatter-to-primary ratio (SPR), the mean glandular dose (MGD) and the signal

  15. Breast Self- Examination Contradiction

    OpenAIRE

    Ayla Akkas Gursoy

    2008-01-01

    Breast cancer is very important health problem among women in the World and Turkey. Although treatment chance is very rising and survival is getting longer thanks to early diagnosis in breast cancer. Some discussion is making related to breast self examination which is one of the early detection methods in recent years. This article consider the discussions about breast self examination under the historical development light. [TAF Prev Med Bull 2008; 7(3.000): 257-260

  16. Breast Self- Examination Contradiction

    Directory of Open Access Journals (Sweden)

    Ayla Akkas Gursoy

    2008-06-01

    Full Text Available Breast cancer is very important health problem among women in the World and Turkey. Although treatment chance is very rising and survival is getting longer thanks to early diagnosis in breast cancer. Some discussion is making related to breast self examination which is one of the early detection methods in recent years. This article consider the discussions about breast self examination under the historical development light. [TAF Prev Med Bull 2008; 7(3.000: 257-260

  17. Broccoli Sprout Extract in Treating Patients With Breast Cancer

    Science.gov (United States)

    2018-06-04

    Ductal Breast Carcinoma; Ductal Breast Carcinoma In Situ; Estrogen Receptor Negative; Estrogen Receptor Positive; Invasive Breast Carcinoma; Lobular Breast Carcinoma; Postmenopausal; Stage IA Breast Cancer; Stage IB Breast Cancer; Stage IIA Breast Cancer; Stage IIB Breast Cancer

  18. Correlação dos aspectos laparoscópicos com as alterações histológicas glandulares das lesões endometrióticas peritoneais Correlation between laparoscopic aspects and glandular hystological findings of peritoneal endometriotic lesions

    Directory of Open Access Journals (Sweden)

    Francesco Antonio Viscomi

    2004-09-01

    Full Text Available OBJETIVOS: Correlacionar os aspectos laparoscópicos com os achados histológicos na endometriose peritoneal para facilitar a compreensão da teoria evolutiva da endometriose. MÉTODOS: Foram selecionadas aleatoriamente para o presente estudo prospectivo 67 pacientes submetidas a laparoscopia, com diagnóstico de endometriose peritoneal. A avaliação laparoscópica foi baseada no aspecto visual do implante suspeito de endometriose peritoneal, submetido a estudo anatomopatológico. De acordo com o aspecto laparoscópico, as lesões foram agrupadas em: grupo V - vermelhas, grupo N - negras, grupo B - brancas. A avaliação histológica foi realizada observando-se as características funcionais do epitélio glandular, a presença de debris intraluminais, o número de mitoses e a relação estroma/glândula. RESULTADOS: As características funcionais do epitélio glandular mostraram associação estatisticamente significante entre os grupos, sendo o epitélio com carcterística secretora encontrado em 68,4% das lesões do grupo V, 15,8% do grupo N e B, enquanto que o epitélio incaracterístico foi encontrado em 19,4% das lesões vermelhas, 38,7% das lesões negras e 41,9% das brancas e o epitélio proliferativo foi observado em 50% das pacientes do grupo B e em 25% dos grupos V e N (p=0,011. Em relação à presença de debris intraluminais, também houve diferença significante entre os grupos, estando presentes em 58,4% das lesões negras, 33,3% das lesões brancas e 8,3% das lesões vermelhas (p=0,016. Quanto ao número de mitoses, não houve diferença significante nos três grupos de estudo (p=0,428. O mesmo foi observado na relação estroma/glândula, não havendo diferença significante nos grupos de estudo (p=0,159. CONCLUSÃO: A associação entre atividade funcional nas lesões vermelhas e baixa atividade funcional nas lesões negras e brancas, bem como a presença de debris intraluminais nos diferentes grupos, reforçam a teoria

  19. Tubercular breast abscess

    Directory of Open Access Journals (Sweden)

    Pradeep S Jadhav

    2013-01-01

    Full Text Available Tubercular breast abscess is a rare clinical entity and affects women from mainly the Indian subcontinent. It often mimics breast carcinoma and pyogenic breast abscess clinically. Routine laboratory investigations are not helpful in the diagnosis. Fine needle aspiration cytology (FNAC or biopsy is essential for diagnosis, and tuberculous culture when positive may be very useful to start antitubercular treatment.

  20. Breast sarcomas. Literature review

    Directory of Open Access Journals (Sweden)

    D. A. Ryabchikov

    2014-01-01

    Full Text Available The article presents an overview of the literature about breast sarcomas (nonepithelial malignances. Primary sarcomas are extremely rare, with less than 1 % of all malignant tumors of the breast. Breast carcinomas cause an increased interest of the scientists due to their unique clinical and pathological features and unpredictable prognosis.

  1. Risks of Breast Implants

    Science.gov (United States)

    ... have a risk of developing a type of cancer called breast implant-associated anaplastic large cell lymphoma (BIA-ALCL) in the breast tissue surrounding the implant. BIA-ALCL is not breast cancer. Women diagnosed with BIA-ALCL may need to ...

  2. Breast Cancer (For Kids)

    Science.gov (United States)

    ... Staying Safe Videos for Educators Search English Español Breast Cancer KidsHealth / For Kids / Breast Cancer What's in this ... for it when they are older. What Is Breast Cancer? The human body is made of tiny building ...

  3. Power spectrum analysis of the x-ray scatter signal in mammography and breast tomosynthesis projections.

    Science.gov (United States)

    Sechopoulos, Ioannis; Bliznakova, Kristina; Fei, Baowei

    2013-10-01

    To analyze the frequency domain characteristics of the signal in mammography images and breast tomosynthesis projections with patient tissue texture due to detected scattered x-rays. Acquisitions of x-ray projection images of 19 different patient breasts were simulated using previously acquired volumetric patient images. Acquisition of these images was performed with a dedicated breast CT prototype system, and the images were classified into voxels representing skin, adipose, and glandular tissue with a previously validated automated algorithm. The classified three dimensional images then underwent simulated mechanical compression representing that which is performed during acquisition of mammography and breast tomosynthesis images. The acquisition of projection images of each patient breast was simulated using Monte Carlo methods with each simulation resulting in two images: one of the primary (non-scattered) signal and one of the scatter signal. To analyze the scatter signal for both mammography and breast tomosynthesis, two projections images of each patient breast were simulated, one with the x-ray source positioned at 0° (mammography and central tomosynthesis projection) and at 30° (wide tomosynthesis projection). The noise power spectra (NPS) for both the scatter signal alone and the total signal (primary + scatter) for all images were obtained and the combined results of all patients analyzed. The total NPS was fit to the expected power-law relationship NPS(f) = k/f β and the results were compared with those previously published on the power spectrum characteristics of mammographic texture. The scatter signal alone was analyzed qualitatively and a power-law fit was also performed. The mammography and tomosynthesis projections of three patient breasts were too small to analyze, so a total of 16 patient breasts were analyzed. The values of β for the total signal of the 0° projections agreed well with previously published results. As expected, the scatter

  4. Library based x-ray scatter correction for dedicated cone beam breast CT

    International Nuclear Information System (INIS)

    Shi, Linxi; Zhu, Lei; Vedantham, Srinivasan; Karellas, Andrew

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  5. Library based x-ray scatter correction for dedicated cone beam breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu [Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Vedantham, Srinivasan; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2016-08-15

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide r