WorldWideScience

Sample records for vapour inhalation presenting

  1. The fourth international symposium on inhaled particles and vapours, Edinburgh 22-26 September 1975

    International Nuclear Information System (INIS)

    Bailey, M.R.

    1975-11-01

    A brief account is given of the symposium, organised by the British Occupational Hygiene Society in co-operation with the European Communities. Its objective was to present the results of the latest research into the inhalation and retention of dusts and vapours, the way they are handled by the body, and their effects, with emphasis on the basic mechanisms involved. (author)

  2. The effects of acute gasoline vapour inhalation on some haematological indices of albino Wistar rats

    OpenAIRE

    Chukwudi Onyeka John Okonkwo; Ailende Daniel Ehileboh; Eddy Nwobodo; Charles Chijioke Dike

    2016-01-01

    Objective: To find out if Gasoline vapour has some effects on haematological indices when inhaled by experimental rats. Methods: The standard method for laboratory operating procedure recommended by World Health Organization was used in all the analysis done. Forty two albino Wistar rats comprising twenty one males (160–220 g) and twenty one females (140–190 g) were sampled into six groups consisting of four test groups and two control groups. The test groups were exposed to gasoline vapou...

  3. Pneumonitis after Inhalation of Mercury Vapours

    Directory of Open Access Journals (Sweden)

    JD Glezos

    2006-01-01

    Full Text Available A 43-year-old man presented to hospital with pneumonia but only after discharge from hospital did he admit to deliberate prior inhalation of mercury. His pulmonary involvement appeared to resolve almost completely with antibiotics and supportive care. Nevertheless, persisting elevated urinary excretion of mercury required two courses of chelation therapy. No serious systemic sequelae were observed.

  4. Hydrazine inhalation hepatotoxicity.

    Science.gov (United States)

    Kao, Yung Hsiang; Chong, C H; Ng, W T; Lim, D

    2007-10-01

    Abstract Hydrazine is a hazardous chemical commonly used as a reactant in rocket and jet fuel cells. Animal studies have demonstrated hepatic changes after hydrazine inhalation. Human case reports of hydrazine inhalation hepatotoxicity are rare. We report a case of mild hepatotoxicity following brief hydrazine vapour inhalation in a healthy young man, which resolved completely on expectant management.

  5. Inhalation of air polluted with gasoline vapours alters the levels of amino acid neurotransmitters in the cerebral cortex, hippocampus, and hypothalamus of the rat.

    Science.gov (United States)

    Kinawy, Amal A; Ezzat, Ahmed R; Al-Suwaigh, Badryah R

    2014-08-01

    This study was designed to investigate the impact of exposure to the vapours of two kinds of gasoline, a widely used fuel for the internal combustion engines on the levels of the amino acid neurotransmitters of the rat brain. Recent studies provide strong evidence for a causative role for traffic-related air pollution on morbidity outcomes as well as premature death (Health Effects Institute, 2009; Levy et al., 2010; von Stackelberg et al., 2013). Exposure to the vapours of gasoline or its constituents may be accidental, occupational by workers at fuel stations and factories, or through abuse as a mean of mood alteration (Fortenberry, 1985; Mc Garvey et al., 1999). Two kinds of gasoline that are common in Egypt have been used in this study. The first contains octane enhancers in the form of lead derivatives (leaded gasoline; G1) and the other contains methyl-tertiary butyl ether (MTBE) as the octane enhancer (unleaded gasoline; G2). The levels of the major excitatory (aspartic acid and glutamic acid) and the inhibitory (GABA and glycine) amino acid neurotransmitters were determined in the cerebral cortex, hippocampus, and hypothalamus. The current study revealed that the acute inhalation of air polluted with the two types of gasoline vapours (1/2 LC50 for 30 min) induced elevation in the levels of aspartic and glutamic acids along with a decrease in glycine and GABA in most studied brain areas. Chronic inhalation of both types of gasoline (a single daily 30-min session of 1/5 LC50 for 60 days) caused a significant increase in the aspartic and glutamic acid concentrations of the hippocampus without affecting the levels of GABA or glycine. Acute and chronic inhalation of either one of G1 and G2 vapours induced a disturbance and fluctuation in the levels of the free amino acids that act as excitatory and inhibitory neurotransmitters in the brain areas under investigation. These neurotransmitters are fundamental for the communicative functioning of the neurons and such

  6. Formulation and Development of Metered Dose Inhalations of Salbutamol in Solution Form

    Science.gov (United States)

    Khale, Anubha; Bajaj, Amrita

    2011-01-01

    In the present study attempts were made to prepare metered dose inhalation of salbutamol in solution form and compared it with the marketed metered dose inhalation in suspension form. Solution form of the drug was found better than marketed suspension formulation with respect to homogeneity and content uniformity. Propellant blend P-11 and P-12 in the proportion 30:70 was selected as it gave optimum vapour pressure. Surfactant oleic acid in concentration 10 mg per can was selected as it gave best results with clarity, spray pattern, vapour pressure, content per spray and rate of evaporation. Ethyl alcohol 2 ml per can was used as a cosolvent to give a clear solution, optimum vapour pressure, maximum content per spray and fair rate of evaporation. The selected formulation was subjected to the physico-chemical evaluation tests as per the standard pharmacopoeial procedures and the characteristics of the formulations were further compared with a conventional marketed formulation. In vitro study reveled the net respirable fraction was better than marketed preparation. PMID:22923867

  7. Ethanol vapour induced dilated cardiomyopathy in chick embryos

    International Nuclear Information System (INIS)

    Kamran, K.; Khan, M.Y.; Minhas, L.A.

    2013-01-01

    Objective: To study the effects of ethanol vapour inhalation on the heart chambers of chick embryo. Methods: The case-control study was conducted at the College of Physicians and Surgeons Pakistan regional centre in Islamabad from January to October 2007. Both experimental and control groups were divided into three sub-groups each, based on the day of the sacrifice. Each group was dissected on day 7, day 10 and day 22 or hatching whichever was earlier. The experimental sub-groups sacrificed on day 7, day 10 and on hatching, were exposed to ethanol vapours till day 6, 9 and 9 of incubation respectively. The diameter of all 4 chambers was measured in experimental hearts and compared with age-matched controls. SPSS 10 was used for statistical analysis. Results: Ethanol vapour exposure caused widening of all heart chambers in the experimental chick embryos sacrificed on day 7 and day 10 compared to the controls. The chambers of newly hatched chick hearts showed dilatation in all the chambers except the left ventricle. Conclusion: Ethanol vapour exposure during development affects the heart, resulting in the widening of all heart chambers. The exposure is as dangerous as drinking alcohol. Alcohol vapour exposure during development leads to progressive dilatation in different heart chambers, producing dilated cardiomyopathy. (author)

  8. Toxic spongiform leucoencephalopathy after inhaling heroin vapour

    International Nuclear Information System (INIS)

    Weber, W.; Henkes, H.; Kuehne, D.; Moeller, P.; Bade, K.

    1998-01-01

    This is a report of clinical, CT and MRI findings in a patient with toxic spongiform leucoencephalopathy after heroin ingestion. The disease is observed in drug addicts who inhale pre-heated heroin. The clinical onset, which usually occurs some days or even longer after the last heroin consumption, is characterized by a cerebellar syndrome. The cerebellar hemispheres, the cerebellar and cerebral peduncles and the pyramidal tract may be affected. Spongiform demyelination is the morphological substrate of the lesions, which are not contrast enhancing, hypodense on CT and hyperintense on T2-weighted MRI. The frequently perfect symmetry of the affection of functional systems points to a toxic and/or metabolic pathophysiological mechanism. (orig.)

  9. Toxicological perspectives of inhaled therapeutics and nanoparticles.

    Science.gov (United States)

    Hayes, Amanda J; Bakand, Shahnaz

    2014-07-01

    The human respiratory system is an important route for the entry of inhaled therapeutics into the body to treat diseases. Inhaled materials may consist of gases, vapours, aerosols and particulates. In all cases, assessing the toxicological effect of inhaled therapeutics has many challenges. This article provides an overview of in vivo and in vitro models for testing the toxicity of inhaled therapeutics and nanoparticles implemented in drug delivery. Traditionally, inhalation toxicity has been performed on test animals to identify the median lethal concentration of airborne materials. Later maximum tolerable concentration denoted by LC0 has been introduced as a more ethically acceptable end point. More recently, in vitro methods have been developed, allowing the direct exposure of airborne material to cultured human target cells on permeable porous membranes at the air-liquid interface. Modifications of current inhalation therapies, new pulmonary medications for respiratory diseases and implementation of the respiratory tract for systemic drug delivery are providing new challenges when conducting well-designed inhalation toxicology studies. In particular, the area of nanoparticles and nanocarriers is of critical toxicological concern. There is a need to develop toxicological test models, which characterise the toxic response and cellular interaction between inhaled particles and the respiratory system.

  10. Toxic spongiform leucoencephalopathy after inhaling heroin vapour

    Energy Technology Data Exchange (ETDEWEB)

    Weber, W.; Henkes, H.; Kuehne, D. [Klinik fuer Allgemeine Roentgendiagnostik und Neuroradiologie, Alfried-Krupp-Krankenhaus, Alfried Krupp Strasse 21, D-45117, Essen (Germany); Moeller, P.; Bade, K. [Neurologische Klinik, Knappschafts-Krankenhaus, D-45657 Recklinghausen (Germany)

    1998-06-02

    This is a report of clinical, CT and MRI findings in a patient with toxic spongiform leucoencephalopathy after heroin ingestion. The disease is observed in drug addicts who inhale pre-heated heroin. The clinical onset, which usually occurs some days or even longer after the last heroin consumption, is characterized by a cerebellar syndrome. The cerebellar hemispheres, the cerebellar and cerebral peduncles and the pyramidal tract may be affected. Spongiform demyelination is the morphological substrate of the lesions, which are not contrast enhancing, hypodense on CT and hyperintense on T2-weighted MRI. The frequently perfect symmetry of the affection of functional systems points to a toxic and/or metabolic pathophysiological mechanism. (orig.) With 2 figs., 2 tabs., 26 refs.

  11. the reproductive dysfunction effects of gasoline inhalation in albino

    African Journals Online (AJOL)

    admin

    exposure to inhalation gasoline, which generally saturate the ambient air of their workplaces. In this study, we challenged male and female albino rats with gasoline vapour and monitored the endocrine disruptive effects as part of a comprehensive study of the health risks faced by refinery workers in Nigeria. The ultimate.

  12. The reproductive dysfunction effects of gasoline inhalation in albino rats.

    Science.gov (United States)

    Ugwoke, C C; Nwobodo, E D; Unekwe, P; Odike, M; Chukwumai, S T; Amilo, G

    2005-01-01

    Daily exposure to fuel vapour may pose significant health risk to exposed individuals. Fifteen each of male and female albino rats weighing between 110-230g were divided into test (10) and control (5) groups each. The test animals; were exposed to inhalation gasoline for one hour daily for twenty-one consecutive days. All animals were then bled and the serum levels of the reproductive hormones determined. The results showed significant [P inhalation gasoline exposure significantly [P < 0.05] lowers the levels of reproductive hormones in albino rats and may thus interfere with reproduction.

  13. Distribution and excretion of inhaled mercury vapour

    Energy Technology Data Exchange (ETDEWEB)

    Gage, J C

    1961-01-01

    Rats have been exposed for varying periods to an atmosphere containing 1 mg/cu.m. mercury vapor. The toxic effects produced showed resemblances to signs of mercurialism in man. An attempt has been made to study the kinetics of absorption and excretion of mercury from measurements of the amounts excreted and stored in the tissues. The efficiency of absorption of mercury by the rat lung is about 50%. A small proportion is excreted into the gut. After about 10 days of continuous exposure a steady state is reached in which excretion balances absorption. During short exposures the turnover of mercury in all tissues except brain is fairly rapid and most of the mercury is cleared from the body within a week after exposure. The urinary excretion of mercury, during the initial stage of storage in the tissues and the final stage of clearance, shows divergencies from the simple exponential pattern; there appears to be a delay mechanism in the kidney which, in intermittent exposures, may result in the occurrence of peak excretion during periods of non-exposure. After more prolonged exposures the mercury in the kidney appears to be converted to a form which is only very slowly excreted. The significance of the urinary excretion of mercury by man after industrial exposure to mercury vapour is discussed. The rat experiments suggest that single measurements will give only limited information concerning industrial conditions, but that an approximate assessment of the total absorbed during a working week would be obtained if it were possible to make a seven-day collection of urine. Repeated measurements after exposure would yield information on the duration of exposure and would have some diagnostic value.

  14. Different physiological and behavioural effects of e-cigarette vapour and cigarette smoke in mice.

    Science.gov (United States)

    Ponzoni, L; Moretti, M; Sala, M; Fasoli, F; Mucchietto, V; Lucini, V; Cannazza, G; Gallesi, G; Castellana, C N; Clementi, F; Zoli, M; Gotti, C; Braida, D

    2015-10-01

    Nicotine is the primary addictive substance in tobacco smoke and electronic cigarette (e-cig) vapour. Methodological limitations have made it difficult to compare the role of the nicotine and non-nicotine constituents of tobacco smoke. The aim of this study was to compare the effects of traditional cigarette smoke and e-cig vapour containing the same amount of nicotine in male BALB/c mice exposed to the smoke of 21 cigarettes or e-cig vapour containing 16.8 mg of nicotine delivered by means of a mechanical ventilator for three 30-min sessions/day for seven weeks. One hour after the last session, half of the animals were sacrificed for neurochemical analysis, and the others underwent mecamylamine-precipitated or spontaneous withdrawal for the purposes of behavioural analysis. Chronic intermittent non-contingent, second-hand exposure to cigarette smoke or e-cig vapour led to similar brain cotinine and nicotine levels, similar urine cotinine levels and the similar up-regulation of α4β2 nicotinic acetylcholine receptors in different brain areas, but had different effects on body weight, food intake, and the signs of mecamylamine-precipitated and spontaneous withdrawal episodic memory and emotional responses. The findings of this study demonstrate for the first time that e-cig vapour induces addiction-related neurochemical, physiological and behavioural alterations. The fact that inhaled cigarette smoke and e-cig vapour have partially different dependence-related effects indicates that compounds other than nicotine contribute to tobacco dependence. Copyright © 2015 Elsevier B.V. and ECNP. All rights reserved.

  15. We didn't start this fireless vapour: e-cigarette legislation in Australia.

    Science.gov (United States)

    Krawitz, Marilyn

    2014-12-01

    Electronic cigarettes (or e-cigarettes) are devices that heat a cartridge containing a solution that becomes a vapour for the user to inhale. The vapour may or may not contain nicotine. E-cigarettes do not contain tar and other toxins, which traditional cigarettes do, so they may be less damaging to people's health than smoking traditional cigarettes. However, no studies exist about the long-term effects of using e-cigarettes yet. It is illegal to sell e-cigarettes with nicotine in Australia, though Australians may import a three-month supply from overseas. It is legal to sell e-cigarettes with nicotine in some other jurisdictions, such as the United Kingdom and the European Union. This article argues that the Australian government should consider legalising the sale of e-cigarettes with nicotine in Australia for health, safety and economic reasons and to protect youth. If the sale of e-cigarettes with nicotine becomes legal, the Australian government must strictly regulate it.

  16. Impact of gasoline inhalation on some neurobehavioural characteristics of male rats

    Science.gov (United States)

    2009-01-01

    Background This paper examines closely and compares the potential hazards of inhalation of two types of gasoline (car fuel). The first type is the commonly use leaded gasoline and the second is the unleaded type enriched with oxygenate additives as lead substituent in order to raise the octane number. The impacts of gasoline exposure on Na+, K+-ATPase, superoxide dismutase (SOD), acetylcholinesterase (AChE), total protein, reduced glutathione (GSH), and lipid peroxidation (TBARS) in the cerebral cortex, and monoamine neurotransmitters dopamine (DA), norepinephrine (NE) and serotonin (5-HT) in the cerebral cortex, hippocampus, cerebellum and hypothalamus were evaluated. The effect of gasoline exposure on the aggressive behaviour tests was also studied. Results The present results revealed that gasoline inhalation induced significant fluctuations in the levels of the monoamine neurotransmitters in the studied brain regions. This was concomitant with a decrease in Na+, K+-ATPase activity and total protein content. Moreover, the group exposed to the unleaded gasoline exhibited an increase in lipid peroxidation and a decrease in AChE and superoxide dismutase activities. These physiological impairments were accompanied with a higher tendency towards aggressive behaviour as a consequence to gasoline inhalation. Conclusion It is concluded from the present work that chronic exposure to either the leaded or the unleaded gasoline vapours impaired the levels of monoamine neurotransmitters and other biochemical parameters in different brain areas and modulated several behavioural aspects related to aggression in rats. PMID:19930677

  17. Impact of gasoline inhalation on some neurobehavioural characteristics of male rats.

    Science.gov (United States)

    Kinawy, Amal A

    2009-11-24

    This paper examines closely and compares the potential hazards of inhalation of two types of gasoline (car fuel). The first type is the commonly use leaded gasoline and the second is the unleaded type enriched with oxygenate additives as lead substituent in order to raise the octane number. The impacts of gasoline exposure on Na+, K+-ATPase, superoxide dismutase (SOD), acetylcholinesterase (AChE), total protein, reduced glutathione (GSH), and lipid peroxidation (TBARS) in the cerebral cortex, and monoamine neurotransmitters dopamine (DA), norepinephrine (NE) and serotonin (5-HT) in the cerebral cortex, hippocampus, cerebellum and hypothalamus were evaluated. The effect of gasoline exposure on the aggressive behaviour tests was also studied. The present results revealed that gasoline inhalation induced significant fluctuations in the levels of the monoamine neurotransmitters in the studied brain regions. This was concomitant with a decrease in Na+, K+-ATPase activity and total protein content. Moreover, the group exposed to the unleaded gasoline exhibited an increase in lipid peroxidation and a decrease in AChE and superoxide dismutase activities. These physiological impairments were accompanied with a higher tendency towards aggressive behaviour as a consequence to gasoline inhalation. It is concluded from the present work that chronic exposure to either the leaded or the unleaded gasoline vapours impaired the levels of monoamine neurotransmitters and other biochemical parameters in different brain areas and modulated several behavioural aspects related to aggression in rats.

  18. Impact of gasoline inhalation on some neurobehavioural characteristics of male rats

    Directory of Open Access Journals (Sweden)

    Kinawy Amal A

    2009-11-01

    Full Text Available Abstract Background This paper examines closely and compares the potential hazards of inhalation of two types of gasoline (car fuel. The first type is the commonly use leaded gasoline and the second is the unleaded type enriched with oxygenate additives as lead substituent in order to raise the octane number. The impacts of gasoline exposure on Na+, K+-ATPase, superoxide dismutase (SOD, acetylcholinesterase (AChE, total protein, reduced glutathione (GSH, and lipid peroxidation (TBARS in the cerebral cortex, and monoamine neurotransmitters dopamine (DA, norepinephrine (NE and serotonin (5-HT in the cerebral cortex, hippocampus, cerebellum and hypothalamus were evaluated. The effect of gasoline exposure on the aggressive behaviour tests was also studied. Results The present results revealed that gasoline inhalation induced significant fluctuations in the levels of the monoamine neurotransmitters in the studied brain regions. This was concomitant with a decrease in Na+, K+-ATPase activity and total protein content. Moreover, the group exposed to the unleaded gasoline exhibited an increase in lipid peroxidation and a decrease in AChE and superoxide dismutase activities. These physiological impairments were accompanied with a higher tendency towards aggressive behaviour as a consequence to gasoline inhalation. Conclusion It is concluded from the present work that chronic exposure to either the leaded or the unleaded gasoline vapours impaired the levels of monoamine neurotransmitters and other biochemical parameters in different brain areas and modulated several behavioural aspects related to aggression in rats.

  19. Inhalation exposure of children to fragrances present in scented toys.

    Science.gov (United States)

    Masuck, I; Hutzler, C; Jann, O; Luch, A

    2011-12-01

    When utilized in the perfuming of children's toys, fragrances capable of inducing contact allergy in human skin may also become bioavailable to children via the inhalation route. The aim of this study was to determine the area-specific emission rates of 24 fragrances from a plasticized PVC reference material that was meant to mimic a real plastic toy. This material was introduced into an emission chamber for 28 days at handling conditions or at worst-case conditions. As a result, fragrances can be separated into three categories according to their emission rates ranging from 0.0041 to 16.2 mg/m² × h, i.e., highly volatile, semivolatile, and low-volatile compounds. Compounds of the first and second categories were monitored with decreasing emission rates. Substances of the third category were detected with increasing emission rates over time. Further, higher temperatures led to higher emission rates. The emission concentration of fragrances from four real scented toys varied between 1.10 and 107 μg/m³ at day 1 in the test chamber. Therefore, short-term inhalation exposure to fragrances originating from toys was in the range of 0.53-2700 ng/kg BW/d for the children of age 1 and older. Long-term exposure to these fragrances was calculated in the range of 2.2-220 ng/kg BW/d. Besides household products and cosmetics, fragrances can be found in toys for children. Some fragrances are known contact allergens in the skin, but there is a lack of information on their effects in the human respiratory tract. Here, we analyzed and categorized fragrances present in a plasticized PVC reference material according to their emission profiles and volatility. We also demonstrate that volatile fragrances are being emitted from real toys and thus may get inhaled under consumer conditions to different extents. © 2011 John Wiley & Sons A/S.

  20. Considering the use of polyethylene vapour barriers in temperate climates

    Energy Technology Data Exchange (ETDEWEB)

    Lawton, M.D. [Morrison Hershfield Ltd., Vancouver, BC (Canada); Brown, W.C. [Morrison Hershfield Ltd., Ottawa, ON (Canada)

    2003-07-01

    Most building envelope assemblies in Canada must include a vapour barrier in order to comply with Canadian building codes. The installation of sheet polyethylene between the studs and the interior sheathing has been the most common method because it provides more diffusion resistance than necessary to control condensation within a building envelope assembly. It has been suggested that the presence of a polyethylene vapour barrier on the warm-in-winter side of the insulation may actually cause moisture problems because a very low permeance material increases average moisture levels. This paper examined the theory that a vapour barrier at this location restricts drying of moisture that enters the building from outside. Pacific coastal regions of Canada and the United States were presented as examples. Other ways that a polyethylene vapour barrier affects wall performance were also presented. The advanced hygrothermal model HygIRC, developed by Canada's National Research Council, was used to simulate the performance of a wall assembly. Results indicate that eliminating the low permeance polyethylene vapour barrier does not necessarily reduce the risk of moisture problems. Removal of the vapour barrier may have some negative effects, such as increased risk of periodic moisture accumulation and mold growth on paper-faced gypsum board. 7 refs., 2 tabs., 7 figs.

  1. Vapour pressures and enthalpies of vapourization of a series of the linear aliphatic nitriles

    International Nuclear Information System (INIS)

    Emel'yanenko, Vladimir N.; Verevkin, Sergey P.; Koutek, Bohumir; Doubsky, Jan

    2005-01-01

    Vapour pressures and the molar enthalpies of vapourization ΔlgHm-bar of the linear aliphatic nitriles C 7 -C 17 have been determined by the transpiration method. Kovat's indices of these compounds were measured by capillary gas-chromatography. A linear correlation of enthalpies of vapourization ΔlgHm-bar at T=298.15 K of the nitriles studied with the Kovats indices has been found

  2. No sodium in the vapour plumes of Enceladus.

    Science.gov (United States)

    Schneider, Nicholas M; Burger, Matthew H; Schaller, Emily L; Brown, Michael E; Johnson, Robert E; Kargel, Jeffrey S; Dougherty, Michele K; Achilleos, Nicholas A

    2009-06-25

    The discovery of water vapour and ice particles erupting from Saturn's moon Enceladus fuelled speculation that an internal ocean was the source. Alternatively, the source might be ice warmed, melted or crushed by tectonic motions. Sodium chloride (that is, salt) is expected to be present in a long-lived ocean in contact with a rocky core. Here we report a ground-based spectroscopic search for atomic sodium near Enceladus that places an upper limit on the mixing ratio in the vapour plumes orders of magnitude below the expected ocean salinity. The low sodium content of escaping vapour, together with the small fraction of salt-bearing particles, argues against a situation in which a near-surface geyser is fuelled by a salty ocean through cracks in the crust. The lack of observable sodium in the vapour is consistent with a wide variety of alternative eruption sources, including a deep ocean, a freshwater reservoir, or ice. The existing data may be insufficient to distinguish between these hypotheses.

  3. Technical committee meeting on aerosol formation, vapour deposits and sodium vapour trapping. Summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1977-01-01

    The papers presented at the LMFBR meeting on aerosol formation covered the following four main topics: theoretical studies on aerosol behaviour and comparison with experimental results; techniques for measurement of aerosols; techniques for trapping sodium vapour and aerosols in gas circuits; design of components having to cope with aerosol deposits. The resulting summaries, conclusions and recommendations which were were agreed upon are presented.

  4. Technical committee meeting on aerosol formation, vapour deposits and sodium vapour trapping. Summary report

    International Nuclear Information System (INIS)

    1977-01-01

    The papers presented at the LMFBR meeting on aerosol formation covered the following four main topics: theoretical studies on aerosol behaviour and comparison with experimental results; techniques for measurement of aerosols; techniques for trapping sodium vapour and aerosols in gas circuits; design of components having to cope with aerosol deposits. The resulting summaries, conclusions and recommendations which were were agreed upon are presented

  5. The mechanical vapour compression process applied to seawater desalination

    International Nuclear Information System (INIS)

    Murat, F.; Tabourier, B.

    1984-01-01

    The authors present the mechanical vapour compression process applied to sea water desalination. As an example, the paper presents the largest unit so far constructed by SIDEM using this process : a 1,500 m3/day unit installed in the Nuclear Power Plant of Flamanville in France which supplies a high quality process water to that plant. The authors outline the advantages of this process and present also the serie of mechanical vapour compression unit that SIDEM has developed in a size range in between 25 m3/day and 2,500 m3/day

  6. The Liquid Vapour Interface

    DEFF Research Database (Denmark)

    Als-Nielsen, Jens Aage

    1985-01-01

    In this short review we are concerned with the density variation across the liquid-vapour interface, i.e. from the bulk density of the liquid to the essentially zero density of the vapour phase. This density variation can in principle be determined from the deviation of the reflectivity from...

  7. Estimation of inhalation flow profile using audio-based methods to assess inhaler medication adherence

    Science.gov (United States)

    Lacalle Muls, Helena; Costello, Richard W.; Reilly, Richard B.

    2018-01-01

    Asthma and chronic obstructive pulmonary disease (COPD) patients are required to inhale forcefully and deeply to receive medication when using a dry powder inhaler (DPI). There is a clinical need to objectively monitor the inhalation flow profile of DPIs in order to remotely monitor patient inhalation technique. Audio-based methods have been previously employed to accurately estimate flow parameters such as the peak inspiratory flow rate of inhalations, however, these methods required multiple calibration inhalation audio recordings. In this study, an audio-based method is presented that accurately estimates inhalation flow profile using only one calibration inhalation audio recording. Twenty healthy participants were asked to perform 15 inhalations through a placebo Ellipta™ DPI at a range of inspiratory flow rates. Inhalation flow signals were recorded using a pneumotachograph spirometer while inhalation audio signals were recorded simultaneously using the Inhaler Compliance Assessment device attached to the inhaler. The acoustic (amplitude) envelope was estimated from each inhalation audio signal. Using only one recording, linear and power law regression models were employed to determine which model best described the relationship between the inhalation acoustic envelope and flow signal. Each model was then employed to estimate the flow signals of the remaining 14 inhalation audio recordings. This process repeated until each of the 15 recordings were employed to calibrate single models while testing on the remaining 14 recordings. It was observed that power law models generated the highest average flow estimation accuracy across all participants (90.89±0.9% for power law models and 76.63±2.38% for linear models). The method also generated sufficient accuracy in estimating inhalation parameters such as peak inspiratory flow rate and inspiratory capacity within the presence of noise. Estimating inhaler inhalation flow profiles using audio based methods may be

  8. Detection of polar vapours

    International Nuclear Information System (INIS)

    Blyth, D.A.

    1980-01-01

    Apparatus for monitoring for polar vapours in a gas consists of (i) a body member defining a passage through which a continuous stream of the gas passes; (ii) an ionising source associated with a region of the passage such that ionization of the gas stream takes place substantially only within the region and also any polar vapour molecules present therein will react with the gas formed to generate ion clusters; and (iii) an electrode for collecting ions carried by the gas stream, the electrode being positioned in the passage downstream of the region and separated from the region by a sufficient distance to ensure that no substantial number of the gas ions formed in said region remains in the gas stream at the collector electrode whilst ensuring that a substantial proportion of the ion clusters formed in the region does remain in the gas stream at the collector electrode. (author)

  9. Inhaled corticosteroids do not influence the early inflammatory response and clinical presentation of hospitalized subjects with COPD exacerbation.

    Science.gov (United States)

    Crisafulli, Ernesto; Guerrero, Mónica; Menéndez, Rosario; Huerta, Arturo; Martinez, Raquel; Gimeno, Alexandra; Soler, Néstor; Torres, Antoni

    2014-10-01

    Inhaled corticosteroids are anti-inflammatory medications that can down-regulate the immunologic response in patients with COPD; however, their role at onset of COPD exacerbation is still not understood. The aim of this study was to assess the early inflammatory response and clinical presentation of patients with COPD exacerbation mediated by inhaled corticosteroids. Prospective data were collected on 123 hospitalized subjects with COPD exacerbation over a 30-month period at 2 Spanish university hospitals. Based on domiciliary use, comparative analyses were performed between subjects who did not use inhaled corticosteroids (n = 58) and subjects who did (n = 65). Measurements of serum biomarkers were recorded on admission to the hospital (day 1) and on day 3; clinical, physiological, microbiological, and severity data and mortality/readmission rates were also recorded. At days 1 and 3, both groups showed a similar inflammatory response; fluticasone produced lower levels of interleukin-8 compared with budesonide (P clinical features considered were similar in the 2 groups; multivariate analysis predicting clinical complications on hospitalization showed air-flow obstruction severity as the only predictive factor (odds ratio 3.13, 95% CI 1.13-8.63, P = .02). Our study demonstrates a lack of inhaled corticosteroid influence in the early systemic inflammatory response to and clinical presentation of COPD exacerbation. Copyright © 2014 by Daedalus Enterprises.

  10. Modelling water vapour permeability through atomic layer deposition coated photovoltaic barrier defects

    Energy Technology Data Exchange (ETDEWEB)

    Elrawemi, Mohamed, E-mail: Mohamed.elrawemi@hud.ac.uk [EPSRC Centre for Innovative Manufacturing in Advanced Metrology, School of Computing and Engineering, University of Huddersfield, Huddersfield (United Kingdom); Blunt, Liam; Fleming, Leigh [EPSRC Centre for Innovative Manufacturing in Advanced Metrology, School of Computing and Engineering, University of Huddersfield, Huddersfield (United Kingdom); Bird, David, E-mail: David.Bird@uk-cpi.com [Centre for Process Innovation Limited, Sedgefield, County Durham (United Kingdom); Robbins, David [Centre for Process Innovation Limited, Sedgefield, County Durham (United Kingdom); Sweeney, Francis [EPSRC Centre for Innovative Manufacturing in Advanced Metrology, School of Computing and Engineering, University of Huddersfield, Huddersfield (United Kingdom)

    2014-11-03

    Transparent barrier films such as Al{sub 2}O{sub 3} used for prevention of oxygen and/or water vapour permeation are the subject of increasing research interest when used for the encapsulation of flexible photovoltaic modules. However, the existence of micro-scale defects in the barrier surface topography has been shown to have the potential to facilitate water vapour ingress, thereby reducing cell efficiency and causing internal electrical shorts. Previous work has shown that small defects (≤ 3 μm lateral dimension) were less significant in determining water vapour ingress. In contrast, larger defects (≥ 3 μm lateral dimension) seem to be more detrimental to the barrier functionality. Experimental results based on surface topography segmentation analysis and a model presented in this paper will be used to test the hypothesis that the major contributing defects to water vapour transmission rate are small numbers of large defects. The model highlighted in this study has the potential to be used for gaining a better understanding of photovoltaic module efficiency and performance. - Highlights: • A model of water vapour permeation through barrier defects is presented. • The effect of the defects on the water vapour permeability is investigated. • Defect density correlates with water vapour permeability. • Large defects may dominate the permeation properties of the barrier film.

  11. Sensing response of copper phthalocyanine salt dispersed glass with organic vapours

    Energy Technology Data Exchange (ETDEWEB)

    Ridhi, R.; Sachdeva, Sheenam; Saini, G. S. S.; Tripathi, S. K., E-mail: surya@pu.ac.in [Department of Physics, Center of Advanced Study in Physics, Panjab University, Chandigarh-160 014 (INDIA) Fax: +91-172-2783336; Tel.:+91-172-2544362 (India)

    2016-05-06

    Copper Phthalocyanine and other Metal Phthalocyanines are very flexible and tuned easily to modify their structural, spectroscopic, optical and electrical properties by either functionalizing them with various substituent groups or by replacing or adding a ligand to the central metal atom in the phthalocyanine ring and accordingly can be made sensitive and selective to various organic species or gaseous vapours. In the present work, we have dispersed Copper Phthalocyanine Salt (CuPcS) in sol-gel glass form using chemical route sol-gel method and studied its sensing mechanism with organic vapours like methanol and benzene and found that current increases onto their exposure with vapours. A variation in the activation energies was also observed with exposure of vapours.

  12. Chronic psychological effects of exposure to mercury vapour among chlorine-alkali plant workers.

    Science.gov (United States)

    Pranjić, N; Sinanović, O; Jakubović, R

    2003-01-01

    Quantitative assessment of nervous system function is essential in characterising the nature and extent of impairment in individuals experiencing symptoms following work-place mercury vapour exposure. The purpose of this study was the application of standardised tests of behavioural, psychomotor and memory function to understand the neuropsychological effects of mercury in occupationally exposed chlorine-alkali plant workers. The study comprised 45 workers at a chlorine-alkali plant with the mean age of 39.36 +/- 5.94 years, who had been exposed to daily inhalation of mercury vapour over long-term employment of 16.06 +/- 4.29 years. The cumulative mercury index was 155.32 +/- 95.02 micrograms/g creatinine, the mean of urinary mercury concentrations on the first day of the study was 119.50 +/- 157.24 micrograms/g creatinine, and the mean of urinary mercury concentrations 120 days after cessation of exposure was 21.70 +/- 26.07 micrograms/g creatinine. The analysis included tests of behavioural, psychomotor and memory function. The behavioural test battery consisted of: Environmental Worry Scale (EWS), Minnesota Modified Personal Inventory (MMPI-2), Purdue standard 25 minute test, and adapted, 10 minutes test, Bender's Visual-Motor Gestalt test (BGT), and Eysenck Personality Inventory (EPQ). The data were compared to a control group of 32 not directly exposed workers. In the mercury vapour exposed workers with relatively high level exposure to inorganic mercury vapour (TWA/TLV = 0.12 mg/m3/0.025 mg/m3) we identified somatic depression-hypochondria symptoms with higher scores for scales: hysteria (P introvert behaviour (EPQ, MMPI-2). The cognitive disturbances in mercury-exposed workers were identified as: concentration difficulty, psychomotor, perceptual and motor coordination disturbances, and brain effects. We identified fine tremor of the hands in 34 out of 45 mercury-exposed workers (BGT). The results point to a relationship between the duration of mercury

  13. Inhalation toxicity of methanol/gasoline in rats: effects of 13-week exposure.

    Science.gov (United States)

    Poon, R; Park, G; Viau, C; Chu, I; Potvin, M; Vincent, R; Valli, V

    1998-01-01

    The subchronic inhalation toxicity of a methanol/gasoline blend (85% methanol, 15% gasoline, v/v) was studied in rats. Sprague Dawley rats (10 animals per group) of both sexes were exposed to vapours of methanol/gasoline at 50/3, 500/30 and 5000/300ppm for 6 hours per day, 5 days per week, for 13 weeks. Control animals inhaled filtered room air only. Control recovery and high dose recovery groups were also included which inhaled room air for an extra 4 weeks following the treatment period. No clinical signs of toxicity were observed in the treatment group and their growth curves were not significantly different from the control. Except for decreased forelimb grip strength in high dose females, no treatment-related neurobehavioural effects (4-6 hours post inhalation) were observed using screening tests which included cage-side observations, righting reflex, open field activities, and forelimb and hindlimb grip strength. At necropsy, the organ to body weight ratios for the liver, spleen, testes, thymus and lungs were not significantly different from the control group. There were no treatment-related effects in the hematological endpoints and no elevation in serum formate levels. Minimal serum biochemical changes were observed with the only treatment-related change being the decreased creatinine in the females. A dose-related increase in urinary ascorbic acid was detected in males after 2, 4 and 8 weeks of exposure, but not after the 12th week, and in females only at week-2. Increased urinary albumin was observed in treated males starting at the lowest dose and at all exposure periods, but not in females. A treatment-related increase in urinary beta 2-microglobulin was detected in males at week-2 only. Except for mild to moderate mucous cell metaplasia in nasal septum B, which occurred more often and with a slightly higher degree of severity in the low dose groups of both sexes, and presence of a minimal degree of interstitial lymphocyte infiltration in the prostate

  14. Inhalant allergies in children.

    Science.gov (United States)

    Mims, James W; Veling, Maria C

    2011-06-01

    Children with chronic or recurrent upper respiratory inflammatory disease (rhinitis) should be considered for inhalant allergies. Risk factors for inhalant allergies in children include a first-degree relative with allergies, food allergy in infancy, and atopic dermatitis. Although inhalant allergies are rare in infancy, inhalant allergies are common in older children and impair quality of life and productivity. Differentiating between viral and allergic rhinitis can be challenging in children, but the child's age, history, and risk factors can provide helpful information. Allergic rhinitis is a risk factor for asthma, and if one is present, medical consideration of the other is warranted. Copyright © 2011 Elsevier Inc. All rights reserved.

  15. Inhalant Abuse and Dextromethorphan.

    Science.gov (United States)

    Storck, Michael; Black, Laura; Liddell, Morgan

    2016-07-01

    Inhalant abuse is the intentional inhalation of a volatile substance for the purpose of achieving an altered mental state. As an important, yet underrecognized form of substance abuse, inhalant abuse crosses all demographic, ethnic, and socioeconomic boundaries, causing significant morbidity and mortality in school-aged and older children. This review presents current perspectives on epidemiology, detection, and clinical challenges of inhalant abuse and offers advice regarding the medical and mental health providers' roles in the prevention and management of this substance abuse problem. Also discussed is the misuse of a specific "over-the-counter" dissociative, dextromethorphan. Copyright © 2016 Elsevier Inc. All rights reserved.

  16. Vapour trap development and operational experience

    International Nuclear Information System (INIS)

    Jansing, W.; Kirchner, G.; Menck, J.

    1977-01-01

    Sodium aerosols have the unpleasant characteristic that they deposit at places with low temperature level. This effect can be utilized when sodium aerosols are to be trapped at places which are determined beforehand. Thus vapour traps were developed which can filter sodium vapour from the cover gas. By this means the necessity was eliminated to heat all gas lines and gas systems with trace heaters just as all sodium lines are heated. It was of special interest for the INTERATOM to develop vapour traps which must not be changed or cleaned after a certain limited operating period. The vapour traps were supposed to enable maintenance free operation, i.e. they were to operate 'self cleaning'

  17. Intercomparison of TCCON and MUSICA Water Vapour Products

    Science.gov (United States)

    Weaver, D.; Strong, K.; Deutscher, N. M.; Schneider, M.; Blumenstock, T.; Robinson, J.; Notholt, J.; Sherlock, V.; Griffith, D. W. T.; Barthlott, S.; García, O. E.; Smale, D.; Palm, M.; Jones, N. B.; Hase, F.; Kivi, R.; Ramos, Y. G.; Yoshimura, K.; Sepúlveda, E.; Gómez-Peláez, Á. J.; Gisi, M.; Kohlhepp, R.; Warneke, T.; Dohe, S.; Wiegele, A.; Christner, E.; Lejeune, B.; Demoulin, P.

    2014-12-01

    We present an intercomparison between the water vapour products from the Total Carbon Column Observing Network (TCCON) and the MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water (MUSICA), two datasets from ground-based Fourier Transform InfraRed (FTIR) spectrometers with good global representation. Where possible, comparisons to radiosondes are also included. The near-infrared TCCON measurements are optimized to provide precise monitoring of greenhouse gases for carbon cycle studies; however, TCCON's retrievals also produce water vapour products. The mid-infrared MUSICA products result from retrievals optimized to give precise and accurate information about H2O, HDO, and δD. The MUSICA water vapour products have been validated by extensive intercomparisons with H2O and δD in-situ measurements made from ground, radiosonde, and aircraft (Schneider et al. 2012, 2014), as well as by intercomparisons with satellite-based H2O and δD remote sensing measurements (Wiegele et al., 2014). This dataset provides a valuable reference point for other measurements of water vapour. This study is motivated by the limited intercomparisons performed for TCCON water vapour products and limited characterisation of their uncertainties. We compare MUSICA and TCCON products to assess the potential for TCCON measurements to contribute to studies of the water cycle, water vapour's role in climate and use as a tracer for atmospheric dynamics, and to evaluate the performance of climate models. The TCCON and MUSICA products result from measurements taken using the same FTIR instruments, enabling a comparison with constant instrumentation. The retrieval techniques differ, however, in their method and a priori information. We assess the impact of these differences and characterize the comparability of the TCCON and MUSICA datasets.

  18. Sound speed of isobaric heat capacity in the saturated and superheated vapour of cesium, rubidium and potassium

    International Nuclear Information System (INIS)

    Novikov, I.I.; Roschupkin, V.V.

    1985-01-01

    The paper reviews the work carried out on the thermodynamic properties of alkali metal vapours. The most systematic investigations concern the sound velocity measurements for saturated and superheated vapours of caesium, for saturated vapour of rubidium, and for superheated vapour of potassium. The Joule-Thompson coefficient has been studied in caesium vapour, and the isobaric heat capacity of potassium vapour has also been examined. The experimental methods for all these experiments are described, and the data obtained are presented in tabular form. (U.K.)

  19. Objective measurement of inhaler inhalation flow profile using acoustic methods

    Energy Technology Data Exchange (ETDEWEB)

    Lacalle, H.; Taylor, T.E.; Marco, S.; Reilly, R.B.

    2016-07-01

    Patients with asthma and chronic obstructive pulmonary diseases (COPD) are mostly treated with inhalers that deliver medication directly to their airways. Drug delivery from dry powder inhalers (DPIs) is very much reliant on the inhalation manoeuvre, specifically the peak inspiratory flow rate (PIFR), inspiratory capacity (IC) and inhalation rise time (IRT) of the inhalation. It has been widely reported that patients may not follow correct inhalation technique while using their inhaler. In this study, a novel acoustic method is proposed to accurately estimate inhalation flow profile using only one inhalation recording for calibration. An Ellipta DPI was placed inside an airtight container with a spirometer connected in order to measure inhalation flow parameters. An acoustic recording device (Inhaler Compliance Assessment (INCA)) was also attached to the DPI. Inhalation audio and flow signals were recorded simultaneously. The data were collected from 20 healthy subjects while performing inhaler inhalations at a range of inspiratory flow rates. A power law regression model was computed to obtain the relationship between the acoustic envelope of the inhalation and flow profile of each recording. Each model was tested on the remaining audio signals to estimate flow profile. The average estimation error was found to be 10.5±0.3% for estimating flow profile from audio signals. Inhalation flow profile parameters (PIFR, IC and IRT) could then be measured from the estimated flow profile with high accuracy giving information on user inhalation technique. This method may assist in improving patient inhaler adherence and overall disease control. (Author)

  20. (Vapour + liquid) equilibria for (2,2-dimethoxypropane + methanol) and (2,2-dimethoxypropane + acetone)

    International Nuclear Information System (INIS)

    Jiang Hui; Li Haoran; Wang Congmin; Tan Taijun; Han Shijun

    2003-01-01

    The isothermal and isobaric (vapour + liquid) equilibria for (2,2-dimethoxypropane + methanol) and (2,2-dimethoxypropane + acetone) measured with an inclined ebulliometer are presented. The experimental results are analysed using the UNIQUAC equation with the temperature-dependent binary parameters with satisfactory results. Isobaric (vapour + liquid) equilibria data for these systems at p=99.99 kPa are compared with the literature data. Experimental vapour pressure of 2,2-dimethoxypropane are also included

  1. Claims in vapour device (e-cigarette) regulation: A Narrative Policy Framework analysis.

    Science.gov (United States)

    O'Leary, Renée; Borland, Ron; Stockwell, Tim; MacDonald, Marjorie

    2017-06-01

    The electronic cigarette or e-cigarette (vapour device) is a consumer product undergoing rapid growth, and governments have been adopting regulations on the sale of the devices and their nicotine liquids. Competing claims about vapour devices have ignited a contentious debate in the public health community. What claims have been taken up in the state arena, and how have they possibly influenced regulatory outcomes? This study utilized Narrative Policy Framework to analyze the claims made about vapour devices in legislation recommendation reports from Queensland Australia, Canada, and the European Union, and the 2016 deeming rule legislation from the United States, and examined the claims and the regulatory outcomes in these jurisdictions. The vast majority of claims in the policy documents represented vapour devices as a threat: an unsafe product harming the health of vapour device users, a gateway product promoting youth tobacco uptake, and a quasi-tobacco product impeding tobacco control. The opportunity for vapour devices to promote cessation or reduce exposure to toxins was very rarely presented, and these positive claims were not discussed at all in two of the four documents studied. The dominant claims of vapour devices as a public health threat have supported regulations that have limited their potential as a harm reduction strategy. Future policy debates should evaluate the opportunities for vapour devices to decrease the health and social burdens of the tobacco epidemic. Copyright © 2017 Elsevier B.V. All rights reserved.

  2. Spontaneuos and Parametric Processes in Warm Rubidium Vapours

    Directory of Open Access Journals (Sweden)

    Dąbrowski M.

    2014-12-01

    Full Text Available Warm rubidium vapours are known to be a versatile medium for a variety of experiments in atomic physics and quantum optics. Here we present experimental results on producing the frequency converted light for quantum applications based on spontaneous and stimulated processes in rubidium vapours. In particular, we study the efficiency of spontaneously initiated stimulated Raman scattering in the Λ-level configuration and conditions of generating the coherent blue light assisted by multi-photon transitions in the diamond-level configuration. Our results will be helpful in search for new types of interfaces between light and atomic quantum memories.

  3. Performance analysis of a potassium-steam two stage vapour cycle

    International Nuclear Information System (INIS)

    Mitachi, Kohshi; Saito, Takeshi

    1983-01-01

    It is an important subject to raise the thermal efficiency in thermal power plants. In present thermal power plants which use steam cycle, the plant thermal efficiency has already reached 41 to 42 %, steam temperature being 839 K, and steam pressure being 24.2 MPa. That is, the thermal efficiency in a steam cycle is facing a limit. In this study, analysis was made on the performance of metal vapour/steam two-stage Rankine cycle obtained by combining a metal vapour cycle with a present steam cycle. Three different combinations using high temperature potassium regenerative cycle and low temperature steam regenerative cycle, potassium regenerative cycle and steam reheat and regenerative cycle, and potassium bleed cycle and steam reheat and regenerative cycle were systematically analyzed for the overall thermal efficiency, the output ratio and the flow rate ratio, when the inlet temperature of a potassium turbine, the temperature of a potassium condenser, and others were varied. Though the overall thermal efficiency was improved by lowering the condensing temperature of potassium vapour, it is limited by the construction because the specific volume of potassium in low pressure section increases greatly. In the combinatipn of potassium vapour regenerative cycle with steam regenerative cycle, the overall thermal efficiency can be 58.5 %, and also 60.2 % if steam reheat and regenerative cycle is employed. If a cycle to heat steam with the bled vapor out of a potassium vapour cycle is adopted, the overall thermal efficiency of 63.3 % is expected. (Wakatsuki, Y.)

  4. Characterisation and optical vapour sensing properties of PMMA thin films

    Energy Technology Data Exchange (ETDEWEB)

    Capan, I. [Balikesir University, Science and Arts Faculty, Physics Department, 10100 Balikesir (Turkey)], E-mail: inci.capan@gmail.com; Tarimci, C. [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Tandogan, Ankara (Turkey); Hassan, A.K. [Sheffield Hallam University, Materials and Engineering Research Institute, City Campus, Pond Street, Sheffield S1 1WB (United Kingdom); Tanrisever, T. [Balikesir University, Science and Arts Faculty, Chemistry Department, 10100 Balikesir (Turkey)

    2009-01-01

    The present article reports on the characterisation of spin coated thin films of poly (methyl methacrylate) (PMMA) for their use in organic vapour sensing application. Thin film properties of PMMA are studied by UV-visible spectroscopy, atomic force microscopy and surface plasmon resonance (SPR) technique. Results obtained show that homogeneous thin films with thickness in the range between 6 and 15 nm have been successfully prepared when films were spun at speeds between 1000-5000 rpm. Using SPR technique, the sensing properties of the spun films were studied on exposures to several halohydrocarbons including chloroform, dichloromethane and trichloroethylene. Data from measured kinetic response have been used to evaluate the sensitivity of the studied films to the various analyte molecules in terms of normalised response (%) per unit concentration (ppm). The highest PMMA film sensitivity of 0.067 normalised response per ppm was observed for chloroform vapour, for films spun at 1000 rpm. The high film's sensitivity to chloroform vapour was ascribed mainly to its solubility parameter and molar volume values. Effect of film thickness on the vapour sensing properties is also discussed.

  5. Comparison of interaction mechanisms of copper phthalocyanine and nickel phthalocyanine thin films with chemical vapours

    Science.gov (United States)

    Ridhi, R.; Singh, Sukhdeep; Saini, G. S. S.; Tripathi, S. K.

    2018-04-01

    The present study deals with comparing interaction mechanisms of copper phthalocyanine and nickel phthalocyanine with versatile chemical vapours: reducing, stable aromatic and oxidizing vapours namely; diethylamine, benzene and bromine. The variation in electrical current of phthalocyanines with exposure of chemical vapours is used as the detection parameter for studying interaction behaviour. Nickel phthalocyanine is found to exhibit anomalous behaviour after exposure of reducing vapour diethylamine due to alteration in its spectroscopic transitions and magnetic states. The observed sensitivities of copper phthalocyanine and nickel phthalcyanine films are different in spite of their similar bond numbers, indicating significant role of central metal atom in interaction mechanism. The variations in electronic transition levels after vapours exposure, studied using UV-Visible spectroscopy confirmed our electrical sensing results. Bromine exposure leads to significant changes in vibrational bands of metal phthalocyanines as compared to other vapours.

  6. [Qualitative Determination of Organic Vapour Using Violet and Visible Spectrum].

    Science.gov (United States)

    Jiang, Bo; Hu, Wen-zhong; Liu, Chang-jian; Zheng, Wei; Qi, Xiao-hui; Jiang, Ai-li; Wang, Yan-ying

    2015-12-01

    Vapours of organic matters were determined qualitatively employed with ultraviolet-visible absorption spectroscopy. Vapours of organic matters were detected using ultraviolet-visible spectrophotometer employing polyethylene film as medium, the ultraviolet and visible absorption spectra of vegetable oil vapours of soybean oil, sunflower seed oil, peanut oil, rapeseed oil, sesame oil, cotton seed oil, tung tree seed oil, and organic compound vapours of acetone, ethyl acetate, 95% ethanol, glacial acetic acid were obtained. Experimental results showed that spectra of the vegetable oil vapour and the organic compound vapour could be obtained commendably, since ultra violet and visible spectrum of polyethylene film could be deducted by spectrograph zero setting. Different kinds of vegetable oils could been distinguished commendably in the spectra since the λ(max), λ(min), number of absorption peak, position, inflection point in the ultra violet and visible spectra obtained from the vapours of the vegetable oils were all inconsistent, and the vapours of organic compounds were also determined perfectly. The method had a good reproducibility, the ultraviolet and visible absorption spectra of the vapours of sunflower seed oil in 10 times determination were absolutely the same. The experimental result indicated that polyethylene film as a kind of medium could be used for qualitative analysis of ultraviolet and visible absorption spectroscopy. The method for determination of the vapours of the vegetable oils and organic compounds had the peculiarities of fast speed analysis, well reproducibility, accuracy and reliability and low cost, and so on. Ultraviolet and visible absorption spectrum of organic vapour could provide feature information of material vapour and structural information of organic compound, and provide a novel test method for identifying vapour of compound and organic matter.

  7. A vapourized Δ(9)-tetrahydrocannabinol (Δ(9)-THC) delivery system part I: development and validation of a pulmonary cannabinoid route of exposure for experimental pharmacology studies in rodents.

    Science.gov (United States)

    Manwell, Laurie A; Charchoglyan, Armen; Brewer, Dyanne; Matthews, Brittany A; Heipel, Heather; Mallet, Paul E

    2014-01-01

    Most studies evaluating the effects of Δ(9)-tetrahydrocannabinol (Δ(9)-THC) in animal models administer it via a parenteral route (e.g., intraperitoneal (IP) or intravenous injection (IV)), however, the common route of administration for human users is pulmonary (e.g., smoking or vapourizing marijuana). A vapourized Δ(9)-THC delivery system for rodents was developed and used to compare the effects of pulmonary and parenteral Δ(9)-THC administration on blood cannabinoid levels and behaviour. Sprague-Dawley rats were exposed to pulmonary Δ(9)-THC (1, 5, and 10mg of inhaled vapour) delivered via a Volcano® vapourizing device (Storz and Bickel, Germany) or to parenteral Δ(9)-THC (0.25, 0.5, 1.0, and 1.5mg/kg injected IP). Quantification of Δ(9)-THC and its psychoactive metabolite, 11-hydroxy-Δ(9)-THC (11-OH-Δ(9)-THC), in blood was determined by liquid chromatography/mass spectrometry (LC/MS). In order to verify the potential for the vapourization procedure to produce a robust conditioned place preference (CPP) or conditioned place avoidance CPA, classical conditioning procedures were systematically varied by altering the exposure time (10 or 20min) and number of exposed rats (1 or 2) while maintaining the same vapourization dose (10mg). Blood collected at 20min intervals showed similar dose-dependent and time-dependent changes in Δ(9)-THC and 11-OH-Δ(9)-THC for both pulmonary and parenteral administration of Δ(9)-THC. However, vapourized Δ(9)-THC induced CPP under certain conditions whereas IP-administered Δ(9)-THC induced CPA. These results support and extend the limited evidence (e.g., in humans, Naef et al., 2004; in rodents, Niyuhire et al., 2007) that Δ(9)-THC produces qualitatively different effects on behaviour depending upon the route of administration. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Stabilization of Leidenfrost vapour layer by textured superhydrophobic surfaces

    KAUST Repository

    Vakarelski, Ivan Uriev

    2012-09-12

    In 1756, Leidenfrost observed that water drops skittered on a sufficiently hot skillet, owing to levitation by an evaporative vapour film. Such films are stable only when the hot surface is above a critical temperature, and are a central phenomenon in boiling. In this so-called Leidenfrost regime, the low thermal conductivity of the vapour layer inhibits heat transfer between the hot surface and the liquid. When the temperature of the cooling surface drops below the critical temperature, the vapour film collapses and the system enters a nucleate-boiling regime, which can result in vapour explosions that are particularly detrimental in certain contexts, such as in nuclear power plants. The presence of these vapour films can also reduce liquid-solid drag. Here we show how vapour film collapse can be completely suppressed at textured superhydrophobic surfaces. At a smooth hydrophobic surface, the vapour film still collapses on cooling, albeit at a reduced critical temperature, and the system switches explosively to nucleate boiling. In contrast, at textured, superhydrophobic surfaces, the vapour layer gradually relaxes until the surface is completely cooled, without exhibiting a nucleate-boiling phase. This result demonstrates that topological texture on superhydrophobic materials is critical in stabilizing the vapour layer and thus in controlling-by heat transfer-the liquid-gas phase transition at hot surfaces. This concept can potentially be applied to control other phase transitions, such as ice or frost formation, and to the design of low-drag surfaces at which the vapour phase is stabilized in the grooves of textures without heating. © 2012 Macmillan Publishers Limited. All rights reserved.

  9. Stabilization of Leidenfrost vapour layer by textured superhydrophobic surfaces

    KAUST Repository

    Vakarelski, Ivan Uriev; Patankar, Neelesh A.; Marston, Jeremy; Chan, Derek Y C; Thoroddsen, Sigurdur T

    2012-01-01

    In 1756, Leidenfrost observed that water drops skittered on a sufficiently hot skillet, owing to levitation by an evaporative vapour film. Such films are stable only when the hot surface is above a critical temperature, and are a central phenomenon in boiling. In this so-called Leidenfrost regime, the low thermal conductivity of the vapour layer inhibits heat transfer between the hot surface and the liquid. When the temperature of the cooling surface drops below the critical temperature, the vapour film collapses and the system enters a nucleate-boiling regime, which can result in vapour explosions that are particularly detrimental in certain contexts, such as in nuclear power plants. The presence of these vapour films can also reduce liquid-solid drag. Here we show how vapour film collapse can be completely suppressed at textured superhydrophobic surfaces. At a smooth hydrophobic surface, the vapour film still collapses on cooling, albeit at a reduced critical temperature, and the system switches explosively to nucleate boiling. In contrast, at textured, superhydrophobic surfaces, the vapour layer gradually relaxes until the surface is completely cooled, without exhibiting a nucleate-boiling phase. This result demonstrates that topological texture on superhydrophobic materials is critical in stabilizing the vapour layer and thus in controlling-by heat transfer-the liquid-gas phase transition at hot surfaces. This concept can potentially be applied to control other phase transitions, such as ice or frost formation, and to the design of low-drag surfaces at which the vapour phase is stabilized in the grooves of textures without heating. © 2012 Macmillan Publishers Limited. All rights reserved.

  10. Water vapour loss measurements on human skin.

    NARCIS (Netherlands)

    Valk, Petrus Gerardus Maria van der

    1984-01-01

    In this thesis, the results of a series of investigations into the barrier function of human skin are presented. In these investigations, the barrier function was assessed by water vapour loss measurements of the skin using a method based on gradient estimation.... Zie: Summary and conclusions

  11. An externally heated copper vapour laser

    International Nuclear Information System (INIS)

    Rochefort, P.A.; Sopchyshyn, F.C.; Selkirk, E.B.; Green, L.W.

    1993-08-01

    A pulsed Copper Vapour Laser (CVL), with a nominal 6 kHz repetition rate, was designed, build, and commissioned at Chalk River laboratories. The laser was required for Resonant Ionization Mass Spectroscopy (RIMS) experiments and for projects associated with Atomic Vapour laser Isotope Separation (AVLIS) studies. For the laser to operate, copper coupons position along the length of a ceramic tube must be heated sufficiently to create an appropriate vapour pressure. The AECL CVL uses an external heater element with a unique design to raise the temperature of the tube. The Cylindrical graphite heating element is shaped to compensate for the large radiation end losses of the laser tube. The use of an external heater saves the expensive high-current-voltage switching device from heating the laser tube, as in most commercial lasers. This feature is especially important given the intermittent usage typical of experimental research. As well, the heater enables better parametric control of the laser output when studying the lasing of copper (or other) vapour. This report outlines the lasing process in copper vapour, describes in detail all three major laser sub-systems: the laser body; the laser tube heater; the high voltage pulsed discharge; and, reports parametric measurements of the individual sub-systems and the laser system as a whole. Also included are normal operating procedures to heat up, run and shut down the laser

  12. Distribution of inhalant allergies in pediatric patients presenting with allergic complaints in the Eastern Anatolia Region.

    Science.gov (United States)

    Kilic, Mehmet; Taskin, Erdal

    2016-08-01

    The objective of this study was to define the distribution of inhalant allergens in pediatric patients in whom sensitization was diagnosed with a skin prick test (SPT) who had presented with allergic complaints. In addition, the correlation between the inhalant allergens detected on the SPT and the patients' demographic features, diagnosis, and laboratory findings was defined. A total of 1415 children among the 4056 patients who presented at a clinic in the Eastern Anatolia region with allergic complaints and who had undergone an SPT were included in this study. On the SPT, sensitization to grass pollens was found in 60.1%, cereals pollens in 57.2%, and Dermatophagoides farinae in 21.8% of the patients. Furthermore, on the SPT, incidence of asthma development was 3.96 times higher (odds ratio 3.96, 95% CI: 1.77-6.83; P=0.001) in patients who were allergic to Dermatophagoides farinae. In our study, differences were found in the study region compared to data from around the world and other regions in Turkey in terms of the distribution of allergies and variations in allergens in patients diagnosed due to variations in climate and plants.

  13. Probabilistic risk assessment for six vapour intrusion algorithms

    NARCIS (Netherlands)

    Provoost, J.; Reijnders, L.; Bronders, J.; Van Keer, I.; Govaerts, S.

    2014-01-01

    A probabilistic assessment with sensitivity analysis using Monte Carlo simulation for six vapour intrusion algorithms, used in various regulatory frameworks for contaminated land management, is presented here. In addition a deterministic approach with default parameter sets is evaluated against

  14. Inhaled Steroids

    Science.gov (United States)

    ... considerations when your dosage changes. What about side effects and inhaled steroids? The most common side effects with inhaled steroids ... inhaled steroid has much less potential for side effects than steroid pills or syrups. There have been concerns regarding ...

  15. Inhalant Abuse

    Science.gov (United States)

    ... is when you pour the product into a bag, hold it over your mouth and nose, and inhale. How is inhalant abuse diagnosed? If you think your child is abusing inhalants, talk to them. Be honest and open. Tell them ...

  16. Atomic origins of water-vapour-promoted alloy oxidation.

    Science.gov (United States)

    Luo, Langli; Su, Mao; Yan, Pengfei; Zou, Lianfeng; Schreiber, Daniel K; Baer, Donald R; Zhu, Zihua; Zhou, Guangwen; Wang, Yanting; Bruemmer, Stephen M; Xu, Zhijie; Wang, Chongmin

    2018-05-07

    The presence of water vapour, intentional or unavoidable, is crucial to many materials applications, such as in steam generators, turbine engines, fuel cells, catalysts and corrosion 1-4 . Phenomenologically, water vapour has been noted to accelerate oxidation of metals and alloys 5,6 . However, the atomistic mechanisms behind such oxidation remain elusive. Through direct in situ atomic-scale transmission electron microscopy observations and density functional theory calculations, we reveal that water-vapour-enhanced oxidation of a nickel-chromium alloy is associated with proton-dissolution-promoted formation, migration, and clustering of both cation and anion vacancies. Protons derived from water dissociation can occupy interstitial positions in the oxide lattice, consequently lowering vacancy formation energy and decreasing the diffusion barrier of both cations and anions, which leads to enhanced oxidation in moist environments at elevated temperatures. This work provides insights into water-vapour-enhanced alloy oxidation and has significant implications in other material and chemical processes involving water vapour, such as corrosion, heterogeneous catalysis and ionic conduction.

  17. Vapour pressure of trideuterioammonia

    Energy Technology Data Exchange (ETDEWEB)

    Calado, J.C.G.; Lopes, J.N.C.; Rebelo, L.P.N. (Instituto Superior Tecnico, Lisbon (Portugal). Centro de Quimica Estrutural)

    1992-09-01

    The H-to-D vapour-pressure isotope effect in liquid ammonia has been measured at 62 temperatures between 228 K and 260 K. The vapour pressures, corrected to 100 per cent nuclidic purity, have been fitted to the equation: T ln r = A+B/T+CT, where r is the vapour-pressure ratio p(NH[sub 3])/p(ND[sub 3]). The fit yielded the parameters: A = -8.22508 K, B = 12338.2 K[sup 2], and C = -0.05544. Comparisons with the results of other authors were made in order to clarify some discrepancies found in the literature. Our values are in accord with the previous results of King et al. and an extrapolation of the fitted equation down to the triple-point temperature gave good agreement with the published results. The fitted equation was used in conjunction with the Clapeyron equation to calculate the difference in the molar enthalpies of vaporization between NH[sub 3] and ND[sub 3]. At T = 230 K that difference is -846 J.mol[sup -1] decreasing to -747 J.mol[sup -1] at 260 K. (author).

  18. Collective dynamics in dense Hg vapour

    International Nuclear Information System (INIS)

    Ishikawa, D; Inui, M; Matsuda, K; Tamura, K; Baron, A Q R; Tsutsui, S; Tanaka, Y; Ishikawa, T

    2004-01-01

    The dynamic structure factor, S(Q,ο), of dense Hg vapour has been measured by high resolution inelastic x-ray scattering for densities of 3.0, 2.1 and 1.0 g cm -3 corresponding to 0.52, 0.36 and 0.17 times the critical density, respectively, and for momentum transfers between 2.0 and 48 nm -1 . Analysis of the longitudinal current-current correlation function in the framework of generalized hydrodynamics reveals that the frequencies of the collective excitations increase faster with Q than estimated from the macroscopic speed of sound. The ratios of the frequencies were found to be 1.27 at 3.0 g cm -3 , 1.12 at 2.1 g cm -3 and 1.10 at 1.0 g cm -3 . The sound velocity obtained from the present experiments is well reproduced by a wavenumber dependent adiabatic sound velocity, which means that the collective modes remain in the spectra of dense Hg vapour. (letter to the editor)

  19. The Seasonal Cycle of Water Vapour on Mars from Assimilation of Thermal Emission Spectrometer Data

    Science.gov (United States)

    Steele, Liam J.; Lewis, Stephen R.; Patel, Manish R.; Montmessin, Franck; Forget, Francois; Smith, Michael D.

    2014-01-01

    We present for the first time an assimilation of Thermal Emission Spectrometer (TES) water vapour column data into a Mars global climate model (MGCM). We discuss the seasonal cycle of water vapour, the processes responsible for the observed water vapour distribution, and the cross-hemispheric water transport. The assimilation scheme is shown to be robust in producing consistent reanalyses, and the global water vapour column error is reduced to around 2-4 pr micron depending on season. Wave activity is shown to play an important role in the water vapour distribution, with topographically steered flows around the Hellas and Argyre basins acting to increase transport in these regions in all seasons. At high northern latitudes, zonal wavenumber 1 and 2 stationary waves during northern summer are responsible for spreading the sublimed water vapour away from the pole. Transport by the zonal wavenumber 2 waves occurs primarily to the west of Tharsis and Arabia Terra and, combined with the effects of western boundary currents, this leads to peak water vapour column abundances here as observed by numerous spacecraft. A net transport of water to the northern hemisphere over the course of one Mars year is calculated, primarily because of the large northwards flux of water vapour which occurs during the local dust storm around L(sub S) = 240-260deg. Finally, outlying frost deposits that surround the north polar cap are shown to be important in creating the peak water vapour column abundances observed during northern summer.

  20. Radiological safety assessment of Thoron inhalation hazards during DDU handling at UMP, Trombay

    International Nuclear Information System (INIS)

    Shailesh, M.; Belhe, M.S.; Malti; Narayani, K.; Satpati, S.K.

    2012-01-01

    Uranium Extraction Division, Bhabha Atomic Research Centre, Mumbai has been producing nuclear grade uranium metal from Ammonium di-uranate received from IRE to meet the fuel requirement of research reactors of Bhabha Atomic Research Centre at Uranium Metal Plant (UMP) in Trombay. In UMP, uranium oxide powder (U 3 O 8 and UO 3 ) is first reduced to uranium dioxide in reduction reactor and is converted to uranium tetra fluoride in hydro fluorination reactor. After removing moisture and acid vapour in expulsion area, reduction of uranium tetrafluoride is carried out with magnesium in magnesio-thermic reduction (MTR) reactor, pure uranium metal ingot with magnesium fluoride slag is produced. Finally natural uranium ingot is separated from slag in ingot discharging area. However deeply depleted uranium (DDU) metal was produced from uranium oxide (reprocessed uranium) received from PREFRE, Tarapur, as a special campaign. External radiation hazards are not dominant during the processing of natural uranium in uranium metal Plant. However it was observed that during processing of DDU metal, external and internal hazards are significant because of daughter products of thoron. Inhalation dose due to thoron was found less during charging of UO 3 powder operation than ingot discharge operation because of pneumatic powder transport system used for charging operation. It is estimated that after introduction of new blower system in different powder handling operation areas, the potential effective inhalation dose due to thoron inhalation may get reduced by 60% - 80%

  1. Autonomous Chemical Vapour Detection by Micro UAV

    Directory of Open Access Journals (Sweden)

    Kent Rosser

    2015-12-01

    Full Text Available The ability to remotely detect and map chemical vapour clouds in open air environments is a topic of significant interest to both defence and civilian communities. In this study, we integrate a prototype miniature colorimetric chemical sensor developed for methyl salicylate (MeS, as a model chemical vapour, into a micro unmanned aerial vehicle (UAV, and perform flights through a raised MeS vapour cloud. Our results show that that the system is capable of detecting MeS vapours at low ppm concentration in real-time flight and rapidly sending this information to users by on-board telemetry. Further, the results also indicate that the sensor is capable of distinguishing “clean” air from “dirty”, multiple times per flight, allowing us to look towards autonomous cloud mapping and source localization applications. Further development will focus on a broader range of integrated sensors, increased autonomy of detection and improved engineering of the system.

  2. Air pollution and fuel vapour induced changes in lung functions: are fuel handlers safe?

    Science.gov (United States)

    Chawla, Anuj; Lavania, A K

    2008-01-01

    Automobile exhaust derived air pollutants have become a major health hazard. Coupled with the inhalation of fuel vapour, as occurs in petrol station workers, this may lead to significant impairment of lung function. Spirometric lung functions were studied in 58 petrol station workers to examine this possibility. The forced vital capacity (FVC), forced expiratory volume in 1 second (FEV1), forced expiratory flow 25%-75% (FEF25-75) and peak expiratory flow (PEF) were recorded and analysed separately for smokers and non-smokers. The workers were divided into 5 groups for analysis of data based on the number of years of work in the petrol pumps. Outdoor air analysis was also carried out. The FVC, FEV1 and PEF declined significantly with increasing years of work in petrol stations in both smokers and non-smokers. Smoking as an independent variable was found to affect the FEV1 significantly but not FVC or PEF. The FEF25-75 was found to be the most affected spirometric value with a significant reduction with increasing years of work. Smoking as such did not affect it. Oxides of nitrogen (NOx), suspended particulate matter (SPM) and particulate matter less than 10 microns (PM10) in outdoor air were higher than the national ambient air quality standards. Exposure to automobile exhaust and fuel vapour impairs lung function in a time-dependent manner. Cigarette smoking appears to accelerate the decline.

  3. A mathematical model of vapour film destabilisation

    International Nuclear Information System (INIS)

    Knowles, J.B.

    1985-04-01

    In a hypothetical reactor accident, destabilisation of an intervening vapour film between the molten fuel and liquid coolant by a weak shock wave (trigger), is considered likely to initiate the molten fuel-coolant interaction. The one-dimensional model presented here is part of a larger programme of fundamental research aimed at improved reactor safety. (U.K.)

  4. Capacitive-discharge-pumped copper bromide vapour laser

    International Nuclear Information System (INIS)

    Sukhanov, V B; Fedorov, V F; Troitskii, V O; Gubarev, F A; Evtushenko, Gennadii S

    2007-01-01

    A copper bromide vapour laser pumped by a high-frequency capacitive discharge is developed. It is shown that, by using of a capacitive discharge, it is possible to built a sealed off metal halide vapour laser of a simple design allowing the addition of active impurities into the working medium. (letters)

  5. CHEMICAL VAPOUR DEPOSITION FROM A RADIATION-SENSITIVE PRECURSOR

    DEFF Research Database (Denmark)

    2017-01-01

    The present invention relates in one aspect to a method of depositing a thin film on a substrate by chemical vapour deposition (CVD) from a radiation-sensitive precursor substance. The method comprises the steps of: (i) placing the substrate in a reaction chamber of a CVD system; (ii) heating...... heating pulse followed by an idle period; (iii) during at least one of the idle periods, providing a pressure pulse of precursor substance inside the reaction chamber by feeding at least one precursor substance to the reaction chamber so as to establish a reaction partial pressure for thin film deposition...... is formed. According to a further aspect, the invention relates to a chemical vapour deposition (CVD) system for depositing a thin film onto a substrate using precursor substances containing at least one radiation sensitive species....

  6. Vapour pressure isotope effects in liquid hydrogen chloride

    Energy Technology Data Exchange (ETDEWEB)

    Lopes, J.N.C.; Calado, J.C.G. (Instituto Superior Tecnico, Lisbon (Portugal)); Jancso, Gabor (Hungarian Academy of Sciences, Budapest (Hungary). Central Research Inst. for Physics)

    1992-08-10

    The difference between the vapour pressures of HCl and DCl has been measured over the temperature range 170-203 K by a differential manometric technique in a precision cryostat. In this range the vapour pressure of HCl is higher than that of DCl by 3.2% at 170 K, decreasing to 0.9% at 200 K. The reduced partition function ratios f[sub l]/f[sub g] derived from the vapour pressure data can be described by the equation ln(f[sub l]/f[sub g]) = (3914.57[+-]10)/T[sup 2] - (17.730[+-]0.055)/T. The experimentally observed H-D vapour pressure isotope effect, together with the values on the [sup 35]Cl-[sup 37]Cl isotope effect available in the literature, is interpreted in the light of the statistical theory of isotope effects in condensed systems by using spectroscopic data of the vapour and liquid phases. The results indicate that the rotation in liquid hydrogen chloride is hindered. Temperature-dependent force constants for the hindered translational and rotational motions were invoked in order to obtain better agreement between the model calculation and experiment. (author).

  7. Vapours of US and EU Market Leader Electronic Cigarette Brands and Liquids Are Cytotoxic for Human Vascular Endothelial Cells

    Science.gov (United States)

    Putzhammer, Raphaela; Doppler, Christian; Jakschitz, Thomas; Heinz, Katharina; Förste, Juliane; Danzl, Katarina; Messner, Barbara; Bernhard, David

    2016-01-01

    The present study was conducted to provide toxicological data on e-cigarette vapours of different e-cigarette brands and liquids from systems viewed as leaders in the e-cigarette market and to compare e-cigarette vapour toxicity to the toxicity of conventional strong high-nicotine cigarette smoke. Using an adapted version of a previously constructed cigarette smoke constituent sampling device, we collected the hydrophilic fraction of e-cigarette vapour and exposed human umbilical vein endothelial cells (HUVECs) to the mixture of compounds present in the vapour of 4 different single-use e-cigarettes, 6 different liquid vapours produced by the same refillable e-cigarette, and one e-cigarette with an exchangeable liquid cartridge. After incubation of cells with various concentrations and for various periods of time we analysed cell death induction, proliferation rates, the occurrence of intra-cellular reactive oxygen species, cell morphology, and we also measured e-cigarette heating coil temperatures. Overall, conventional cigarette smoke extract showed the most severe impact on endothelial cells. However, some e-cigarette vapour extracts showed high cytotoxicity, inhibition of cell proliferation, and alterations in cell morphology, which were comparable to conventional high-nicotine cigarettes. The vapours generated from different liquids using the same e-cigarette show substantial differences, pointing to the liquids as an important source for toxicity. E-cigarette vapour-mediated induction of oxidative stress was significant in one out of the 11 analysed vapours. There is a high variability in the acute cytotoxicity of e-cigarette vapours depending on the liquid and on the e-cigarettes used. Some products showed toxic effects close to a conventional high-nicotine cigarette. Liquid nicotine, menthol content, and the formation of acute intracellular reactive oxygen species do not seem to be the central elements in e-cigarette vapour toxicity. PMID:27351725

  8. Vapours of US and EU Market Leader Electronic Cigarette Brands and Liquids Are Cytotoxic for Human Vascular Endothelial Cells.

    Science.gov (United States)

    Putzhammer, Raphaela; Doppler, Christian; Jakschitz, Thomas; Heinz, Katharina; Förste, Juliane; Danzl, Katarina; Messner, Barbara; Bernhard, David

    2016-01-01

    The present study was conducted to provide toxicological data on e-cigarette vapours of different e-cigarette brands and liquids from systems viewed as leaders in the e-cigarette market and to compare e-cigarette vapour toxicity to the toxicity of conventional strong high-nicotine cigarette smoke. Using an adapted version of a previously constructed cigarette smoke constituent sampling device, we collected the hydrophilic fraction of e-cigarette vapour and exposed human umbilical vein endothelial cells (HUVECs) to the mixture of compounds present in the vapour of 4 different single-use e-cigarettes, 6 different liquid vapours produced by the same refillable e-cigarette, and one e-cigarette with an exchangeable liquid cartridge. After incubation of cells with various concentrations and for various periods of time we analysed cell death induction, proliferation rates, the occurrence of intra-cellular reactive oxygen species, cell morphology, and we also measured e-cigarette heating coil temperatures. Overall, conventional cigarette smoke extract showed the most severe impact on endothelial cells. However, some e-cigarette vapour extracts showed high cytotoxicity, inhibition of cell proliferation, and alterations in cell morphology, which were comparable to conventional high-nicotine cigarettes. The vapours generated from different liquids using the same e-cigarette show substantial differences, pointing to the liquids as an important source for toxicity. E-cigarette vapour-mediated induction of oxidative stress was significant in one out of the 11 analysed vapours. There is a high variability in the acute cytotoxicity of e-cigarette vapours depending on the liquid and on the e-cigarettes used. Some products showed toxic effects close to a conventional high-nicotine cigarette. Liquid nicotine, menthol content, and the formation of acute intracellular reactive oxygen species do not seem to be the central elements in e-cigarette vapour toxicity.

  9. Vapours of US and EU Market Leader Electronic Cigarette Brands and Liquids Are Cytotoxic for Human Vascular Endothelial Cells.

    Directory of Open Access Journals (Sweden)

    Raphaela Putzhammer

    Full Text Available The present study was conducted to provide toxicological data on e-cigarette vapours of different e-cigarette brands and liquids from systems viewed as leaders in the e-cigarette market and to compare e-cigarette vapour toxicity to the toxicity of conventional strong high-nicotine cigarette smoke. Using an adapted version of a previously constructed cigarette smoke constituent sampling device, we collected the hydrophilic fraction of e-cigarette vapour and exposed human umbilical vein endothelial cells (HUVECs to the mixture of compounds present in the vapour of 4 different single-use e-cigarettes, 6 different liquid vapours produced by the same refillable e-cigarette, and one e-cigarette with an exchangeable liquid cartridge. After incubation of cells with various concentrations and for various periods of time we analysed cell death induction, proliferation rates, the occurrence of intra-cellular reactive oxygen species, cell morphology, and we also measured e-cigarette heating coil temperatures. Overall, conventional cigarette smoke extract showed the most severe impact on endothelial cells. However, some e-cigarette vapour extracts showed high cytotoxicity, inhibition of cell proliferation, and alterations in cell morphology, which were comparable to conventional high-nicotine cigarettes. The vapours generated from different liquids using the same e-cigarette show substantial differences, pointing to the liquids as an important source for toxicity. E-cigarette vapour-mediated induction of oxidative stress was significant in one out of the 11 analysed vapours. There is a high variability in the acute cytotoxicity of e-cigarette vapours depending on the liquid and on the e-cigarettes used. Some products showed toxic effects close to a conventional high-nicotine cigarette. Liquid nicotine, menthol content, and the formation of acute intracellular reactive oxygen species do not seem to be the central elements in e-cigarette vapour toxicity.

  10. Bibliography on vapour pressure isotope effects

    International Nuclear Information System (INIS)

    Illy, H.; Jancso, G.

    1976-03-01

    The bibliography of research on vapour pressure isotope effects from 1919 to December 1975 is presented in chronological order. Within each year the references are listed alphabetically according to the name of the first author of each work. The bibliography is followed by a Compound Index containing the names o compounds, but the type of isotopic substituation is not shown. The Author Index includes all authors of the papers. (Sz.N.Z.)

  11. Medical cannabis use in Canada: vapourization and modes of delivery.

    Science.gov (United States)

    Shiplo, Samantha; Asbridge, Mark; Leatherdale, Scott T; Hammond, David

    2016-10-29

    The mode of medical cannabis delivery-whether cannabis is smoked, vapourized, or consumed orally-may have important implications for its therapeutic efficacy and health risks. However, there is very little evidence on current patterns of use among Canadian medical cannabis users, particularly with respect to modes of delivery. The current study examined modes of medical cannabis delivery following regulatory changes in 2014 governing how Canadians access medical cannabis. A total of 364 approved adult Canadian medical cannabis users completed an online cross-sectional survey between April and June 2015. The survey examined patterns of medical cannabis use, modes of delivery used, and reasons for use. Participants were recruited through a convenience sample from nine Health Canada licensed producers. Using a vapourizer was the most popular mode of delivery for medical cannabis (53 %), followed by smoking a joint (47 %). The main reason for using a vapourizer was to reduce negative health consequences associated with smoking. A majority of current vapourizer users reported using a portable vapourizer (67.2 %), followed by a stationary vapourizer (41.7 %), and an e-cigarette or vape pen (19.3 %). Current use of a vapourizer was associated with fewer respiratory symptoms (AOR = 1.28, 95 % CI 1.05-1.56, p = 0.01). The findings suggest an increase in the popularity of vapourizers as the primary mode of delivery among approved medical users. Using vapourizers has the potential to prevent some of the adverse respiratory health consequences associated with smoking and may serve as an effective harm reduction method. Monitoring implications of such current and future changes to medical cannabis regulations may be beneficial to policymakers.

  12. Beam-profile monitor using a sodium-vapour

    CERN Multimedia

    1972-01-01

    Beam-profile monitor using a sodium-vapour curtain at 45 degrees to the ISR beam in Ring I (sodium generator is in white cylinder just left of centre). Electrons produced by ionization of the sodium vapour give an image of the beam on a fluorescent screen that is observed by a TV camera (at upper right).

  13. Hot-wire chemical vapour deposition of carbon nanotubes

    CSIR Research Space (South Africa)

    Cummings, FR

    2006-07-01

    Full Text Available ablation of graphite, carbon-arc discharge and chemical vapour deposition (CVD). However, some of these techniques have been shown to be expensive due to high deposition temperatures and are not easily controllable. Recently hot-wire chemical vapour...

  14. The Droplets Condensate Centering in the Vapour Channel of Short Low Temperature Heat Pipes at High Heat Loads

    Science.gov (United States)

    Seryakov, A. V.; Shakshin, S. L.; Alekseev, A. P.

    2017-11-01

    The results of experimental studies of the process of condensate microdroplets centering contained in the moving moist vapour in the vapour channel of short heat pipes (HPs) for large thermal loads are presented. A vapour channel formed by capillary-porous insert in the form of the inner Laval-liked nozzle along the entire length of the HP. In the upper cover forming a condensation surface in the HP, on the diametrical line are installed capacitive sensors, forming three capacitors located at different distances from the longitudinal axis of the vapour channel. With increasing heat load and the boil beginning in the evaporator a large amount of moist vapour in the vapour channel of HP occur the pressure pulsation with frequency of 400-500 Hz and amplitude up to 1·104Pa. These pulsations affect the moving of the inertial droplets subsystem of the vapour and due to the heterogeneity of the velocity profile around the particle flow in the vapour channel at the diameter of microdroplets occurs transverse force, called the Saffman force and shear microdroplets to the center of vapour channel. Using installed in the top cover capacitors we can record the radial displacement of the condensable microdroplets.

  15. Water vapour trends at several tropospheric levels over South America between 1973 and 2003

    International Nuclear Information System (INIS)

    Morales, L.; Mattar, C.; Da-Silva, L.; Abarca, R.

    2009-01-01

    In this paper water vapour trends were analyzed at several tropospheric levels over South America between 1973 and 2003. It was carried out using in situ values retrieved by 15 radiosonde stations and NCEP NCAR Reanalysis data (NNR). NNR and radiosonde water vapour data were linked to Koeppen-Geiger climatic zones to calculate anomalies, trends, and the non-parametric statistical significance for each mandatory level. A methodology used to process radiosonde data is shown. Water vapour trends in tropical climates presented positive decadal trends. This is statistically significant for the first mandatory levels retrieved by radiosonde. The highest values are presented in average with NNR; the decadal magnitude for climate Af being 0.15 g kg -1 for 1000 and 925 h Pa, and for climate As 0.27 g kg -1 for 925 and 850 h Pa. For non-tropical climates the magnitude trends of specific humidity are affected by the spatial resolution of NNR, which is seen when comparing the results received by the radiosondes. Finally, this paper shows the initial results of water vapour content trends in the last three decades over South America. Strong climatic events and synoptic oscillations were not commented upon.

  16. Inhalation Therapy in Horses.

    Science.gov (United States)

    Cha, Mandy L; Costa, Lais R R

    2017-04-01

    This article discusses the benefits and limitations of inhalation therapy in horses. Inhalation drug therapy delivers the drug directly to the airways, thereby achieving maximal drug concentrations at the target site. Inhalation therapy has the additional advantage of decreasing systemic side effects. Inhalation therapy in horses is delivered by the use of nebulizers or pressured metered dose inhalers. It also requires the use of a muzzle or nasal mask in horses. Drugs most commonly delivered through inhalation drug therapy in horses include bronchodilators, antiinflammatories, and antimicrobials. Copyright © 2016 Elsevier Inc. All rights reserved.

  17. Water vapour and carbon dioxide decrease nitric oxide readings

    NARCIS (Netherlands)

    vanderMark, TW; Kort, E; Meijer, RJ; Postma, DS; Koeter, GH

    Measurement of nitric oxide levels in exhaled ah-is commonly performed using a chemiluminescence detector. However, water vapour and carbon dioxide affect the chemiluminescence process, The influence of these gases at the concentrations present in exhaled air has not vet been studied. For this in

  18. Medical cannabis use in Canada: vapourization and modes of delivery

    Directory of Open Access Journals (Sweden)

    Samantha Shiplo

    2016-10-01

    Full Text Available Abstract Background The mode of medical cannabis delivery—whether cannabis is smoked, vapourized, or consumed orally—may have important implications for its therapeutic efficacy and health risks. However, there is very little evidence on current patterns of use among Canadian medical cannabis users, particularly with respect to modes of delivery. The current study examined modes of medical cannabis delivery following regulatory changes in 2014 governing how Canadians access medical cannabis. Methods A total of 364 approved adult Canadian medical cannabis users completed an online cross-sectional survey between April and June 2015. The survey examined patterns of medical cannabis use, modes of delivery used, and reasons for use. Participants were recruited through a convenience sample from nine Health Canada licensed producers. Results Using a vapourizer was the most popular mode of delivery for medical cannabis (53 %, followed by smoking a joint (47 %. The main reason for using a vapourizer was to reduce negative health consequences associated with smoking. A majority of current vapourizer users reported using a portable vapourizer (67.2 %, followed by a stationary vapourizer (41.7 %, and an e-cigarette or vape pen (19.3 %. Current use of a vapourizer was associated with fewer respiratory symptoms (AOR = 1.28, 95 % CI 1.05–1.56, p = 0.01. Conclusions The findings suggest an increase in the popularity of vapourizers as the primary mode of delivery among approved medical users. Using vapourizers has the potential to prevent some of the adverse respiratory health consequences associated with smoking and may serve as an effective harm reduction method. Monitoring implications of such current and future changes to medical cannabis regulations may be beneficial to policymakers.

  19. Theoretical calculations of primary particle condensation for cadmium and caesium iodide vapours

    Energy Technology Data Exchange (ETDEWEB)

    Buckle, E.R. [Division of Metallurgy, School of Materials, The University, Mappin Street, Sheffield S1 3JD (United Kingdom); Bowsher, B.R. [Chemistry Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1988-10-15

    A theoretical approach to modelling aerosol nucleation from the vapour phase has been developed by Buckle. In this theory, the condensing vapour species are assumed to be transported from an evaporating source across a one-dimensional stagnant boundary layer into an unreactive vapour-free atmosphere. A slip-flow model for interfacial energy and mass flow is combined with this stagnant boundary layer model to yield a set of parameters that uniquely characterise the evaporative flow process (i.e. pressure, source and sink temperatures, sink concentration, and the flux density of heat or mass from the source). To obtain the initial conditions for nucleation the vapour saturation ratio p/p deg is plotted against temperature and compared with the minimum saturation ratio defined by homogeneous nucleation theory. The co-education be represented by a nucleation threshold (or F) diagram. The mass and energy equations of the flow are solved by introducing the Becker-Doering formula for the nucleation rate, and the Stefan diffusion model for particle growth. This gives the rise and fall of supersaturation and the evolution of the particle size distribution along the flow coordinate. In the present studies, the applicability of the model has been tested by considering the condensation of caesium iodide and cadmium vapours under a wide variety of pre-mixed flow conditions of interest to PWR severe accident studies. The model has been used to predict the onset of nucleation and the particle size distribution for single vapour species. Preliminary studies have demonstrated that conditions exist whereby both heterogeneous and homogeneous nucleation can occur simultaneously. This process could account for experimental observations of chemically-different aerosols being formed under severe reactor accident conditions. (author)

  20. The magnetic vapour shield effect at divertor plates during plasma disruptions

    International Nuclear Information System (INIS)

    Piazza, G.; Goel, B.; Hoebel, W.; Wuerz, H.; Landman, I.

    1995-01-01

    Hard disruptions in a TOKAMAK cause a large thermal load on the divertor plates with an instantaneous ablation of a part of the heated material. The produced vapour cloud screens the plasma facing component from the direct interaction with the disrupting plasma (vapour shield effect). In order to quantify the damage to the divertor the magneto-hydrodynamic behaviour of the expanding vapour cloud has been investigated using an extended version of the 1-dimensional Lagrangian hydrodynamic code KATACO. Modelling of the magnetic field effects on the expanding plasma takes into account that the magnetic field is oblique to the divertor (1 1/2 dimensional model). The ''Radiation Heat Conduction Approximation'' has been used for describing the radiative energy transport. In this paper results are presented assuming graphite as divertor material, irradiated with a proton beam of an energy density of 12MJ/m 2 and a duration of 100μs. (orig.)

  1. Evolution of polarization in an atomic vapour with negative refractive index

    International Nuclear Information System (INIS)

    Zhuang Fei; Shen Jianqi

    2006-01-01

    A three-level Lambda-configuration atomic vapour may exhibit simultaneously negative permittivity and permeability in the optical frequency band, and an isotropic left-handed vapour medium could therefore be realized within the framework of quantum optics. One of the most remarkable features of the present scheme is that both the refractive index and the photon helicity reversal inside the vapour can be controllably manipulated by an external coupling light field. The phenomenological Hamiltonian that describes the process of helicity reversal is constructed and the time-dependent Schroedinger equation governing the time evolution of the polarization states of the lightwave is solved by means of the Lewis-Riesenfeld invariant theory. The transition between the polarization states (and hence the accompanied photon helicity reversal), which is exactly analogous to the transition operation between bits in digital circuit, may be valuable for the development of new techniques in quantum optics and would have potential applications in information technology

  2. Vapour pressures of selected organic compounds down to 1 mPa, using mass-loss Knudsen effusion method

    International Nuclear Information System (INIS)

    Fonseca, José M.S.; Gushterov, Nikola; Dohrn, Ralf

    2014-01-01

    Graphical abstract: - Highlights: • A recently described mass-loss Knudsen apparatus was used for measurements of vapour pressures down to around 1 mPa. • Complementary calorimetric studies were performed in a Calvet-type calorimeter. • New vapour pressures are given for benzoic acid and benzanthrone, in ranges in which no consistent data existed. • Vapour pressures for solid n-octadecane are presented, correcting existing values from literature. - Abstract: A recently developed Knudsen effusion apparatus was improved and used for measurements of vapour pressures of selected organic compounds. Calorimetric studies were conducted using a Calvet-type calorimeter, complementing the information obtained for the vapour pressures and facilitating the modelling and analysis of the data. Vapour pressures of benzoic acid, a reference substance, were determined at temperatures between 269 K and 317 K, corresponding to a pressure range from 2 mPa to 1 Pa, extending the range of results available in the literature to lower pressures. Benzanthrone was studied between temperatures 360 K and 410 K (5 mPa–1 Pa) in order to test the apparatus at higher temperatures. Values presented in the literature for the vapour pressure of solid n-octadecane, one of the most promising compounds to be used as “phase change material” for textile applications, were found inconsistent with the triple point of the substance. Sublimation pressures were measured for this compound between T = 286 K and 298 K (2–20 mPa) allowing the correction of the existing values. Finally, vapour pressures of diphenyl carbonate, a compound of high industrial relevance for its use in the production of polycarbonates, were determined from T = 302 K to 332 K (0.02–1 Pa)

  3. Prediction of vapour-liquid and vapour-liquid-liquid equilibria of nitrogen-hydrocarbon mixtures used in J-T refrigerators

    Science.gov (United States)

    Narayanan, Vineed; Venkatarathnam, G.

    2018-03-01

    Nitrogen-hydrocarbon mixtures are widely used as refrigerants in J-T refrigerators operating with mixtures, as well as in natural gas liquefiers. The Peng-Robinson equation of state has traditionally been used to simulate the above cryogenic process. Multi parameter Helmholtz energy equations are now preferred for determining the properties of natural gas. They have, however, been used only to predict vapour-liquid equilibria, and not vapour-liquid-liquid equilibria that can occur in mixtures used in cryogenic mixed refrigerant processes. In this paper the vapour-liquid equilibrium of binary mixtures of nitrogen-methane, nitrogen-ethane, nitrogen-propane, nitrogen-isobutane and three component mixtures of nitrogen-methane-ethane and nitrogen-methane-propane have been studied with the Peng-Robinson and the Helmholtz energy equations of state of NIST REFPROP and compared with experimental data available in the literature.

  4. Contribution to the liquid-vapour equilibrium of potassium and sodium mixtures

    International Nuclear Information System (INIS)

    Schreinlechner, I.; Schwarz, N.

    1975-10-01

    In this paper the phase diagram of the binary system potassium-sodium in the liquid-vapour range was calculated for different pressures and temperatures, assuming the two metals acting as ideal solution. The assumption was verified by experimental results. It is thus possible to calculate the separation factor for the rectification of potassium and to estimate the content of sodium in the vapour phase during experiments with vapourized potassium from the data of the vapour pressures of the pure metals. (author)

  5. Microscopic characterisation of suspended graphene grown by chemical vapour deposition

    NARCIS (Netherlands)

    Bignardi, L.; Dorp, W.F. van; Gottardi, S.; Ivashenko, O.; Dudin, P.; Barinov, A.; de Hosson, J.T.M.; Stöhr, M.; Rudolf, P.

    2013-01-01

    We present a multi-technique characterisation of graphene grown by chemical vapour deposition (CVD) and thereafter transferred to and suspended on a grid for transmission electron microscopy (TEM). The properties of the electronic band structure are investigated by angle-resolved photoelectron

  6. Inhalants in Peru.

    Science.gov (United States)

    Lerner, R; Ferrando, D

    1995-01-01

    In Peru, the prevalence and consequences of inhalant abuse appear to be low in the general population and high among marginalized children. Inhalant use ranks third in lifetime prevalence after alcohol and tobacco. Most of the use appears to be infrequent. Among marginalized children, that is, children working in the streets but living at home or children living in the street, the problem of inhalant abuse is a serious problem. Among children working in the streets but living at home, the lifetime prevalence rate for inhalant abuse is high, ranging from 15 to 45 percent depending on the study being cited. For children living in the streets, the use of inhalant is even more severe. As mentioned earlier in this chapter, most of these street children use inhalants on a daily basis. The lack of research on the problem of inhalant abuse is a serious impediment to development of intervention programs and strategies to address this problem in Peru. Epidemiologic and ethnographic research on the nature and extent of inhalant abuse are obvious prerequisites to targeted treatment and preventive intervention programs. The urgent need for current and valid data is underscored by the unique vulnerability of the youthful population at risk and the undisputed harm that results from chronic abuse of inhalants. Nonetheless, it is important to mention several programs that work with street children. Some, such as the Information and Education Center for the Prevention of Drug Abuse, Generation, and Centro Integracion de Menores en Abandono have shelters where street children are offered transition to a less marginal lifestyle. Teams of street educators provide the children with practical solutions and gain their confidence, as well as offer them alternative socialization experiences to help them survive the streets and avoid the often repressive and counterproductive environments typical of many institutions. Most of the children who go through these programs tend to abandon

  7. Intercomparison of atmospheric water vapour measurements at a Canadian High Arctic site

    Science.gov (United States)

    Weaver, Dan; Strong, Kimberly; Schneider, Matthias; Rowe, Penny M.; Sioris, Chris; Walker, Kaley A.; Mariani, Zen; Uttal, Taneil; McElroy, C. Thomas; Vömel, Holger; Spassiani, Alessio; Drummond, James R.

    2017-08-01

    Water vapour is a critical component of the Earth system. Techniques to acquire and improve measurements of atmospheric water vapour and its isotopes are under active development. This work presents a detailed intercomparison of water vapour total column measurements taken between 2006 and 2014 at a Canadian High Arctic research site (Eureka, Nunavut). Instruments include radiosondes, sun photometers, a microwave radiometer, and emission and solar absorption Fourier transform infrared (FTIR) spectrometers. Close agreement is observed between all combination of datasets, with mean differences ≤ 1.0 kg m-2 and correlation coefficients ≥ 0.98. The one exception in the observed high correlation is the comparison between the microwave radiometer and a radiosonde product, which had a correlation coefficient of 0.92.A variety of biases affecting Eureka instruments are revealed and discussed. A subset of Eureka radiosonde measurements was processed by the Global Climate Observing System (GCOS) Reference Upper Air Network (GRUAN) for this study. Comparisons reveal a small dry bias in the standard radiosonde measurement water vapour total columns of approximately 4 %. A recently produced solar absorption FTIR spectrometer dataset resulting from the MUSICA (MUlti-platform remote Sensing of Isotopologues for investigating the Cycle of Atmospheric water) retrieval technique is shown to offer accurate measurements of water vapour total columns (e.g. average agreement within -5.2 % of GRUAN and -6.5 % of a co-located emission FTIR spectrometer). However, comparisons show a small wet bias of approximately 6 % at the high-latitude Eureka site. In addition, a new dataset derived from Atmospheric Emitted Radiance Interferometer (AERI) measurements is shown to provide accurate water vapour measurements (e.g. average agreement was within 4 % of GRUAN), which usefully enables measurements to be taken during day and night (especially valuable during polar night).

  8. Calculation of vapour bubble growth on the lower generatrix of horizontal tubes

    International Nuclear Information System (INIS)

    Chajka, V.D.

    1987-01-01

    The known models of vapour bubble growth are compared with experimental data. Cinematographic study of vapour formation during water boiling was carried out with elements of horizontal tubes of copper 10, 16, 24, 34 and 70 mm in diameter under the pressure of 100 kPa and specific thermal loadings of 20 and 40 kW/m 2 . According to the experimental data the main volume of vapour phase is occupied by vapour bubbles from the lower part of the horizontal tube. Five stages of vapour bubble growth on the lower generatrix of the horizontal tube: nucleation, growth to the point of breaking off from nucleate centre, the breaking off from the nucleate centre, the tube surface flowing around during floating up, the breaking off from the tube surface, were singled out. The shape of vapour volume varied during the whole period of the bubble growth and it was mainly determined by the horizontal tube diameter. The change of vapour bubble radius in time is the function of the horizontal tube diameter. Comparison of the experimental data with the known models of vapour bubble growth has shown, that every stage of vapour bubble growth on the lower generatrix of the tube is determined by the complex of thermal and hydrodynamic conditions, the effect of which depends on the horizontal tube diameter

  9. Ethanol vapour sensing properties of screen printed WO 3 thick films

    Indian Academy of Sciences (India)

    The ethanol vapour sensing properties of these thick films were investigated at different operating temperatures and ethanol vapour concentrations. The WO3 thick films exhibit excellent ethanol vapour sensing properties with a maximum sensitivity of ∼1424.6% at 400°C in air atmosphere with fast response and recovery ...

  10. Density and vapour pressure of mixed-solvent desiccant systems (propylene glycol or dipropylene glycol or tripropylene glycol + magnesium chloride + water)

    International Nuclear Information System (INIS)

    Chen, Shang-Yi; Soriano, Allan N.; Leron, Rhoda B.; Li, Meng-Hui

    2014-01-01

    In this present work, new experimental data for density and vapour pressure of the mixed-solvent desiccant systems containing {40 wt% glycol (propylene or dipropylene or tripropylene) + (4 or 9 or 16 wt%) magnesium chloride salt + water} were reported for temperatures up to 343.15 K at normal atmospheric condition. The density and vapour pressure data obtained are presented as a function of temperature and composition. An empirical equation was used to correlate the temperature and compositional dependence of the density values. A model based on the mean spherical approximation for aqueous electrolyte solutions incorporating the pseudo-solvent approach was used to represent the vapour pressure as a function of temperature and composition. Satisfactory results were obtained for both density and vapour pressure calculations

  11. MEDUSA: The ExoMars experiment for in-situ monitoring of dust and water vapour

    Science.gov (United States)

    Colangeli, L.; Lopez-Moreno, J. J.; Nørnberg, P.; Della Corte, V.; Esposito, F.; Mazzotta Epifani, E.; Merrison, J.; Molfese, C.; Palumbo, P.; Rodriguez-Gomez, J. F.; Rotundi, A.; Visconti, G.; Zarnecki, J. C.; The International Medusa Team

    2009-07-01

    Dust and water vapour are fundamental components of the Martian atmosphere. In view of tracing the past environmental conditions on Mars, that possibly favoured the appearing of life forms, it is important to study the present climate and its evolution. Here dust and water vapour have (and have had) strong influence. Of major scientific interest is the quantity and physical, chemical and electrical properties of dust and the abundance of water vapour dispersed in the atmosphere and their exchange with the surface. Moreover, in view of the exploration of the planet with automated systems and in the future by manned missions, it is of primary importance to analyse the hazards linked to these environmental factors. The Martian Environmental Dust Systematic Analyser (MEDUSA) experiment, included in the scientific payload of the ESA ExoMars mission, accommodates a complement of sensors, based on optical detection and cumulative mass deposition, that aims to study dust and water vapour in the lower Martian atmosphere. The goals are to study, for the first time, in-situ and quantitatively, physical properties of the airborne dust, including the cumulative dust mass flux, the dust deposition rate, the physical and electrification properties, the size distribution of sampled particles and the atmospheric water vapour abundance versus time.

  12. Stripping of 1.04 MeV per nucleon krypton ions in high molecular weight vapours

    International Nuclear Information System (INIS)

    Eastham, D.A.; Joy, T.; Clark, R.B.; King, R.

    1976-01-01

    Equilibrium charge state distributions have been measured for 1.04 MeV per nucleon krypton ions in heavy vapours with molecular weights from 462 to 6500. Non-equilibrium data are presented for the heaviest vapour. A maximum increase of 0.8 in the mean charge is found relative to a conventional diatomic gas but the pressures required are two orders of magnitude less. (Auth.)

  13. The millennium water vapour drop in chemistry–climate model simulations

    Directory of Open Access Journals (Sweden)

    S. Brinkop

    2016-07-01

    Full Text Available This study investigates the abrupt and severe water vapour decline in the stratosphere beginning in the year 2000 (the "millennium water vapour drop" and other similarly strong stratospheric water vapour reductions by means of various simulations with the state-of-the-art Chemistry-Climate Model (CCM EMAC (ECHAM/MESSy Atmospheric Chemistry Model. The model simulations differ with respect to the prescribed sea surface temperatures (SSTs and whether nudging is applied or not. The CCM EMAC is able to most closely reproduce the signature and pattern of the water vapour drop in agreement with those derived from satellite observations if the model is nudged. Model results confirm that this extraordinary water vapour decline is particularly obvious in the tropical lower stratosphere and is related to a large decrease in cold point temperature. The drop signal propagates under dilution to the higher stratosphere and to the poles via the Brewer–Dobson circulation (BDC. We found that the driving forces for this significant decline in water vapour mixing ratios are tropical sea surface temperature (SST changes due to a coincidence with a preceding strong El Niño–Southern Oscillation event (1997/1998 followed by a strong La Niña event (1999/2000 and supported by the change of the westerly to the easterly phase of the equatorial stratospheric quasi-biennial oscillation (QBO in 2000. Correct (observed SSTs are important for triggering the strong decline in water vapour. There are indications that, at least partly, SSTs contribute to the long period of low water vapour values from 2001 to 2006. For this period, the specific dynamical state of the atmosphere (overall atmospheric large-scale wind and temperature distribution is important as well, as it causes the observed persistent low cold point temperatures. These are induced by a period of increased upwelling, which, however, has no corresponding pronounced signature in SSTs anomalies in the tropics

  14. Delivery of theophylline as dry powder for inhalation

    Directory of Open Access Journals (Sweden)

    Bing Zhu

    2015-12-01

    Full Text Available Theophylline (TP is a very well established orally or intravenously delivered antiasthma drug with many beneficial effects. This study aims to improve asthma treatment by creating a dry powder inhalable (DPI formulation of TP to be delivered directly to the lung, avoiding the side effects associated with conventional oral delivery. The DPI TP formulation was investigated for its physico-chemical characteristics using scanning electron microscopy, laser diffraction, thermal analysis and dynamic vapour sorption. Furthermore, aerosol performance was assessed using the Multi Stage Liquid Impinger (MSLI. In addition, a Calu-3 cell transport assay was conducted in vitro using a modified ACI to study the impact of the DPI formulation on lung epithelial cells. Results showed DPI TP to be physico-chemically stable and of an aerodynamic size suitable for lung delivery. The aerosolisation performance analysis showed the TP DPI formulation to have a fine particle fraction of 29.70 ± 2.59% (P < 0.05 for the TP formulation containing 1.0% (w/w sodium stearate, the most efficient for aerosolisation. Regarding the deposition of TP DPI on Calu-3 cells using the modified ACI, results demonstrated that 56.14 ± 7.62% of the total TP deposited (13.07 ± 1.69 µg was transported across the Calu-3 monolayer over 180 min following deposition, while 37.05 ± 12.62% of the deposited TP was retained in the cells. This could be due to the presence of sodium stearate in the current formulation that increased its lipophilicity. A DPI formulation of TP was developed that was shown to be suitable for inhalation.

  15. Density profiles and collective excitations of a trapped two-component Fermi vapour

    International Nuclear Information System (INIS)

    Amoruso, M.; Meccoli, I.; Minguzzi, A.; Tosi, M.P.

    1999-08-01

    We discuss the ground state and the small-amplitude excitations of a degenerate vapour of fermionic atoms placed in two hyperfine states inside a spherical harmonic trap. An equations-of-motion approach is set up to discuss the hydrodynamic dissipation processes from the interactions between the two components of the fluid beyond mean-field theory and to emphasize analogies with spin dynamics and spin diffusion in a homogeneous Fermi liquid. The conditions for the establishment of a collisional regime via scattering against cold-atom impurities are analyzed. The equilibrium density profiles are then calculated for a two-component vapour of 40 K atoms: they are little modified by the interactions for presently relevant values of the system parameters, but spatial separation of the two components will spontaneously arise as the number of atoms in the trap is increased. The eigenmodes of collective oscillation in both the total particle number density and the concentration density are evaluated analytically in the special case of a symmetric two-component vapour in the collisional regime. The dispersion relation of the surface modes for the total particle density reduces in this case to that of a one-component Fermi vapour, whereas the frequencies of all other modes are shifted by the interactions. (author)

  16. Vapour pressure of D2O - Ice at temperatures below 237 K

    International Nuclear Information System (INIS)

    Heras, J.M.; Asensio, M.C.; Estiu, G.; Viscido, L.

    1984-01-01

    Accurate measurements of heavy water ice vapour pressures between 193 and 253 K have been carried out and an equation based on thermodynamic data has been derived in order to calculate the D 2 O-ice vapour pressures between 173 and 273 K. The agreement between our calculated vapour pressures and the available experimental data including those in this paper, is very good. The comparison between the theoretical calculations of H 2 O-ice and D 2 O-ice vapour pressures confirms the experimental evidence that H 2 O-ice is more volatile than D 2 O-ice at all temperatures in agreement with the vapour isotopic effect theory (VPIE).(author)

  17. Vapours of US and EU Market Leader Electronic Cigarette Brands and Liquids Are Cytotoxic for Human Vascular Endothelial Cells

    OpenAIRE

    Putzhammer, Raphaela; Doppler, Christian; Jakschitz, Thomas; Heinz, Katharina; F?rste, Juliane; Danzl, Katarina; Messner, Barbara; Bernhard, David

    2016-01-01

    The present study was conducted to provide toxicological data on e-cigarette vapours of different e-cigarette brands and liquids from systems viewed as leaders in the e-cigarette market and to compare e-cigarette vapour toxicity to the toxicity of conventional strong high-nicotine cigarette smoke. Using an adapted version of a previously constructed cigarette smoke constituent sampling device, we collected the hydrophilic fraction of e-cigarette vapour and exposed human umbilical vein endothe...

  18. Aerosol formation from heat and mass transfer in vapour-gas mixtures

    International Nuclear Information System (INIS)

    Clement, C.F.

    1985-01-01

    Heat and mass transfer equations and their coupling to the equation for the aerosol size distribution are examined for mixtures in which pressure changes are slow. Specific results in terms of Cn (the condensation number) and Le (the Lewis number - the ratio of the relative rates of evaporation and condensation) are obtained for the proportion of vapour condensing as a aerosol during the cooling and heating of a mixture in a well-mixed cavity. The assumption of allowing no supersaturations, the validity of which is examined, is shown to lead to maximum aerosol formation. For water vapour-air mixtures predictions are made as to temperature regions in which aerosols will evaporate or not form in cooling processes. The results are also qualitatively applied to some atmospheric effects as well as to water aerosols formed in the containment of a pressurized water reactor following a possible accident. In this context, the present conclusion that the whereabouts of vapour condensation is controlled by heat and mass transfer, contrasts with previous assumptions that the controlling factor is relative surface areas. (U.K.)

  19. Range-energy relations and stopping powers of organic liquids and vapours for alpha particles

    International Nuclear Information System (INIS)

    Akhavan-Rezayat, A.; Palmer, R.B.J.

    1980-01-01

    Experimental range-energy relations are presented for alpha particles in methyl alcohol, propyl alcohol, dichloromethane, chloroform and carbon tetrachloride in both the liquid and vapour phases. Stopping power values for these materials and for oxygen gas over the energy range 1.0-8.0 MeV are also given. From these results stopping powers have been derived for the -CH 2 -group and for -Cl occurring in chemical combination in the liquid and vapour phases. The molecular stopping power in the vapour phase is shown to exceed that in the liquid phase by 2-6% below 2 MeV, reducing to negligible differences at about 5 MeV for the materials directly investigated and for the -Cl atom. No significant phase effect is observed for the -CH 2 -group, but it is noted that the uncertainties in the values of the derived stopping powers are much greater in this case. Comparison of the experimental molecular stopping powers with values calculated from elemental values using the Bragg additivity rule shows agreement for vapours but not for liquids. (author)

  20. Analysis of a combined Rankine-vapour-compression refrigeration cycle

    International Nuclear Information System (INIS)

    Aphornratana, Satha; Sriveerakul, Thanarath

    2010-01-01

    This paper describes a theoretical analysis of a heat-powered refrigeration cycle, a combined Rankine-vapour-compression refrigeration cycle. This refrigeration cycle combines an Organic Rankine Cycle and a vapour-compression cycle. The cycle can be powered by low grade thermal energy as low as 60 deg. C and can produce cooling temperature as low as -10 deg. C. In the analysis, two combined Rankine-vapour-compression refrigeration cycles were investigated: the system with R22 and the system with R134a. Calculated COP values between 0.1 and 0.6 of both the systems were found.

  1. Unsteady Particle Deposition in a Human Nasal Cavity during Inhalation

    Directory of Open Access Journals (Sweden)

    Camby M.K. Se

    2010-12-01

    Full Text Available The present study investigates the deposition efficiency during the unsteady inhalation cycle by using Computational Fluid Dynamics (CFD. The unsteady inhalation profile was applied at the outlet of nasopharynx, which had a maximum flow rate of 40.3L/min which corresponds to an equivalent steady inhalation tidal volume flow rate of 24.6L/min. Aerodynamic particle sizes of 5μm and 20μm were studied in order to reflect contrasting Stokes numbered particle behaviour. Two particle deposition efficiencies in the nasal cavity versus time are presented. In general, the deposition of 5μm particles was much less than 20μm particles. The first 0.2 second of the inhalation cycle was found to be significant to the particle transport, since the majority of particles were deposited during this period (i.e. its residence time. Comparisons were also made with its equivalent steady inhalation flow rate which found that the unsteady inhalation produced lower deposition efficiency for both particle sizes.

  2. Copper vapour laser development for Silva

    International Nuclear Information System (INIS)

    Bettinger, A.; Neu, M.; Chatelet, J.

    1993-01-01

    The recent developments of the components for high power Copper Vapour Laser (CVL) have been oriented towards four main goals: high quality laser beam, mainly for the CVL oscillators, increase of the extracted energy out of the amplifying stage, fully integrated and monolithic design for oscillator and amplifier, extended lifetime and high reliability. A first step of this work, which is done under contract with CILAS (Compagnie Industrielle des Lasers) led to an injection seeded oscillator and a 100 Watts amplifier; the present step concerns development of a 400 Watts class amplifier

  3. Numerical Simulation of Pulsation Flow in the Vapour Channel of Short Low Temperature Heat Pipes at High Heat Loads

    Science.gov (United States)

    Seryakov, A. V.; Konkin, A. V.

    2017-11-01

    The results of the numerical simulation of pulsations in the Laval-liked vapour channel of short low-temperature range heat pipes (HPs) are presented. The numerical results confirmed the experimentally obtained increase of the frequency of pulsations in the vapour channel of short HPs with increasing overheat of the porous evaporator relative to the boiling point of the working fluid. The occurrence of pressure pulsations inside the vapour channel in a short HPs is a complex phenomenon associated with the boiling beginning in the capillary-porous evaporator at high heat loads, and appearance the excess amount of vapour above it, leading to the increase in pressure P to a value at which the boiling point TB of the working fluid becomes higher than the evaporator temperature Tev. Vapour clot spreads through the vapour channel and condense, and then a rarefaction wave return from condenser in the evaporator, the boiling in which is resumed and the next cycle of the pulsations is repeated. Numerical simulation was performed using finite element method implemented in the commercial program ANSYS Multiphisics 14.5 in the two-dimensional setting of axis symmetric moist vapour flow with third kind boundary conditions.

  4. The vapour pressure of americium(III) chloride

    International Nuclear Information System (INIS)

    Schuster, W.

    1983-01-01

    Based on the method described by Fischer, an ultramicro-size appratus was developed for static determination of the saturation vapour pressure of highly radioactive materials. The apparatus was tested with MgCl 2 , MnCl 2 , HoCl 3 and ScF 3 . The vapour pressure curves of MgCl 2 and MnCl 2 were in good agreement with other publications and thus proved the efficiency of the apparatus in spite of its difficulties of handling. The values measured for HoCl 3 and ScF 3 differed from those of earlier publications. However, these deviations have been observed before and may be the result of the different measuring principles of static and dynamic methods. For AmCl 3 , the following vapour pressure equation was established: log psub(Torr)=-(11826/T)+10.7. The thermodynamic parameters of the evaporation process were calculated on this basis, and the values for AmBr 3 and PnCl 3 were determined by extrapolation. (orig.) [de

  5. The critical assessment of vapour pressure estimation methods for use in modelling the formation of atmospheric organic aerosol

    Directory of Open Access Journals (Sweden)

    M. H. Barley

    2010-01-01

    Full Text Available A selection of models for estimating vapour pressures have been tested against experimental data for a set of compounds selected for their particular relevance to the formation of atmospheric aerosol by gas-liquid partitioning. The experimental vapour pressure data (all <100 Pa of 45 multifunctional compounds provide a stringent test of the estimation techniques, with a recent complex group contribution method providing the best overall results. The effect of errors in vapour pressures upon the formation of organic aerosol by gas-liquid partitioning in an atmospherically relevant example is also investigated. The mass of organic aerosol formed under typical atmospheric conditions was found to be very sensitive to the variation in vapour pressure values typically present when comparing estimation methods.

  6. Sampling system of atmospheric water vapour for analysis of the γ sub(D) relationship

    International Nuclear Information System (INIS)

    Foloni, L.L.; Villa Nova, N.A.; Salati, E.

    1979-01-01

    The development of a system to water vapour air, for natural isotopic composition analysis of hydrogen is presented. The system uses molecular sieve, type '4A', without cooling agent and permits the choice of a sampling time, variyng from a few minutes to many hours, through the control of the admission of vapour flux. The system has good performance in field conditions, with errors of the order of + -3,0 0 /00 in the γ sub(D)( 0 /00) measurements [pt

  7. Effect of paint on vapour resistivity in plaster

    Directory of Open Access Journals (Sweden)

    de Villanueva, L.

    2008-12-01

    Full Text Available The vapour resistivity of plaster coatings such as paint and their effectiveness as water repellents were studied in several types of plaster. To this end, painted, unpainted and pigmented specimens were tested. Experimental values were collected on diffusion and vapour permeability, or its inverse, water vapour resistivity.The data obtained were very useful for evaluating moisture exchange between plaster and the surrounding air, both during initial drying and throughout the life of the material. They likewise served as a basis for ensuring the proper evacuation of water vapour in walls, and use of the capacity of the porous network in plaster products to regulate moisture content or serve as a water vapour barrier to avoid condensation.Briefly, the research showed that pigments, water-based paints and silicon-based water repellents scantly raised vapour resistance. Plastic paints, enamels and lacquers, however, respectively induced five-, ten- and twenty-fold increases in vapour resistivity, on average.Se estudia el fenómeno de la resistividad al vapor de los de yeso y el efecto impermeabilizante que producen los recubrimientos de pintura sobre diversos tipos de yeso y escayola. Para ello, se ensayan probetas desnudas y recubiertas con distintos tipos de pintura, así como coloreados en masa. Se obtienen valores experimentales de la difusividad o permeabilidad al vapor o su inverso la resistividad al vapor de agua.Los datos obtenidos son muy útiles para valorar el fenómeno del intercambio de humedad entre el yeso y el ambiente, tanto durante el proceso de su secado inicial, como en el transcurso de su vida. Así como para disponer soluciones adecuadas para la evacuación del vapor de agua a través de los cerramientos, para utilizar la capacidad de regulación de la humedad, que proporciona el entramado poroso de los productos de yeso, o para impedir el paso del vapor de agua y evitar condensaciones.Como resumen de la investigación, se

  8. Retrieving mesospheric water vapour from observations of volume scattering radiances

    Directory of Open Access Journals (Sweden)

    P. Vergados

    2009-02-01

    Full Text Available This study examines the possibility for a theoretical approach in the estimation of water vapour mixing ratios in the vicinity of polar mesospheric clouds (PMC using satellite observations of Volume Scattering Radiances (VSR obtained at the wavelength of 553 nm. The PMC scattering properties perturb the underlying molecular Rayleigh scattered solar radiance of the background atmosphere. As a result, the presence of PMC leads to an enhancement in the observed VSR at the altitude of the layer; the PMC VSRs are superimposed on the exponentially decreasing with height Rayleigh VSR, of the PMC-free atmosphere. The ratio between the observed and the Rayleigh VSR of the background atmosphere is used to simulate the environment in which the cloud layer is formed. In addition, a microphysical model of ice particle formation is employed to predict the PMC VSRs. The initial water vapour profile is perturbed until the modelled VSRs match the observed, at which point the corresponding temperature and water vapour profiles can be considered as a first approximation of those describing the atmosphere at the time of the observations. The role of temperature and water vapour in the cloud formation is examined by a number of sensitivity tests suggesting that the water vapour plays a dominant role in the cloud formation in agreement with experimental results. The estimated water vapour profiles are compared with independent observations to examine the model capability in the context of this study. The results obtained are in a good agreement at the peak of the PMC layer although the radiance rapidly decreases with height below the peak. This simplified scenario indicates that the technique employed can give a first approximation estimate of the water vapour mixing ratio, giving rise to the VSR observed in the presence of PMC.

  9. Fission product vapour - aerosol interactions in the containment: simulant fuel studies

    International Nuclear Information System (INIS)

    Beard, A.M.; Benson, C.G.; Bowsher, B.R.

    1988-12-01

    Experiments have been conducted in the Falcon facility to study the interaction of fission product vapours released from simulant fuel samples with control rod aerosols. The aerosols generated from both the control rod and fuel sample were chemically distinct and had different deposition characteristics. Extensive interaction was observed between the fission product vapours and the control rod aerosol. The two dominant mechanisms were condensation of the vapours onto the aerosol, and chemical reactions between the two components; sorption phenomena were believed to be only of secondary importance. The interaction of fission product vapours and reactor materials aerosols could have a major impact on the transport characteristics of the radioactive emission from a degrading core. (author)

  10. Ciclesonide Oral Inhalation

    Science.gov (United States)

    ... use ciclesonide inhalation.Ciclesonide inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Do not use ciclesonide ...

  11. Flunisolide Oral Inhalation

    Science.gov (United States)

    ... use flunisolide inhalation.Flunisolide inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Do not use flunisolide ...

  12. Hydrogen and carbon vapour pressure isotope effects in liquid fluoroform studied by density functional theory

    Energy Technology Data Exchange (ETDEWEB)

    Oi, Takao; Mitome, Ryota; Yanase, Satoshi [Sophia Univ., Tokyo (Japan). Faculty of Science and Technology

    2017-06-01

    H/D and {sup 12}C/{sup 13}C vapour pressure isotope effects (VPIEs) in liquid fluoroform (CHF{sub 3}) were studied at the MPW1PW91/6-31 ++ G(d) level of theory. The CHF{sub 3} monomer and CHF{sub 3} molecules surrounded by other CHF{sub 3} molecules in every direction in CHF{sub 3} clusters were used as model molecules of vapour and liquid CHF{sub 3}. Although experimental results in which the vapour pressure of liquid {sup 12}CHF{sub 3} is higher than that of liquid {sup 12}CDF{sub 3} and the vapour pressure of liquid {sup 13}CHF{sub 3} is higher than that of liquid {sup 12}CHF{sub 3} between 125 and 212 K were qualitatively reproduced, the present calculations overestimated the H/D VPIE and underestimated the {sup 12}C/{sup 13}C VPIE. Temperature-dependent intermolecular interactions between hydrogen and fluorine atoms of neighbouring molecules were required to explain the temperature dependences of both H/D and {sup 12}C/{sup 13}C VPIEs.

  13. Vapour Pressure of Diethyl Phthalate

    Czech Academy of Sciences Publication Activity Database

    Roháč, V.; Růžička, K.; Růžička, V.; Zaitsau, D. H.; Kabo, G. J.; Diky, V.; Aim, Karel

    2004-01-01

    Roč. 36, č. 11 (2004), s. 929-937 ISSN 0021-9614 Institutional research plan: CEZ:AV0Z4072921 Keywords : vapour pressure * diethyl phthalate * correlation Subject RIV: CF - Physical ; Theoretical Chemistry Impact factor: 1.144, year: 2004

  14. Methanol toxicity secondary to inhalant abuse in adult men.

    Science.gov (United States)

    Wallace, Erik A; Green, Adam S

    2009-03-01

    The purpose of this report is to evaluate the presentation, treatment, and outcomes of adults with methanol toxicity from inhalation of carburetor cleaning fluid fumes. Retrospective chart review of adults with positive serum volatile screen for methanol and history of carburetor cleaning fluid fume inhalation. Sixteen patients were admitted 68 times. Eleven Native American patients accounted for 90% of admissions. Sixty-five cases presented with nausea/vomiting; 27 with intoxication or altered mental status; 21 with specific visual complaints. About 93% had a pH or=10 mOsm/L, and 69% had anion gap >16. Ten had an initial serum methanol level or=50 mg/dL. Six patients had a measurable serum ethanol level. Of the 29 patients with a methanol level of 20-49 mg/dL, 20 received intravenous antidote (ethanol or fomepizole); three received an antidote and hemodialysis. All who presented with a serum methanol level >or=50 mg/dL received intravenous ethanol or fomepizole. All visual symptoms resolved before discharge and all patients survived without sequelae. Discussion. This is the largest reported number of cases of methanol toxicity from the inhalation of carburetor cleaning fluid fumes and demonstrates a problem with recurrent abuse among some older Native American men. Intentional inhalation of methanol fumes may produce toxicity. Clinicians need to question patients, especially older Native American men, regarding the possible inhalation of carburetor cleaning fluid fumes in those who present with an unexplained metabolic anion gap acidosis.

  15. Estimation of vapour pressure and partial pressure of subliming ...

    Indian Academy of Sciences (India)

    Administrator

    conditions of (total) pressure by using thermogravimetry under those conditions. Further, from the partial pressure P, it is possible to determine the number of moles of material in the vapour phase using the ideal gas equation, PV = nRT, where P is the partial pressure, V the volume, n number of moles (of the vapour), R the ...

  16. Discrete vapour cavity model with improved timing of opening and collapse of cavities

    NARCIS (Netherlands)

    Bergant, A.; Tijsseling, A.S.; Vítkovský, J.P.; Simpson, A.R.; Lambert, M.F.

    2007-01-01

    Transient vaporous cavitation occurs in hydraulic piping systems when the liquid pressure falls to the vapour pressure. Cavitation may occur as a localized vapour cavity (large void fraction) or as distributed vaporous cavitation (small void fraction). The discrete vapour cavity model (DVCM) with

  17. Vapour phase motion in cryogenic systems containing superheated and subcooled liquids

    Science.gov (United States)

    Kirichenko, Yu. A.; Chernyakov, P. S.; Seregin, V. E.

    The development of vent pipelines, and venting storage tanks for cryogenic liquids requires the knowledge of the law of motion as well as regularities of vapour content variation in the liquid and heat dissipation by the vapour phase. This is a theoretical study of the effect of superheating (subcooling) of the liquid, relative acceleration and reduced pressure upon the size and velocity of noninteracting vapour bubbles, moving in the liquid, and upon their resistance and heat transfer coefficients.

  18. Erosion behaviour of physically vapour-deposited and chemically vapour-deposited SiC films coated on molybdenum during oxygenated argon beam thinning

    International Nuclear Information System (INIS)

    Shikama, T.; Kitajima, M.; Fukutomi, M.; Okada, M.

    1984-01-01

    The erosion behaviour during bombardment with a 5 keV argon beam at room temperature was studied for silicon carbide (SiC) films of thickness of about 10 μm coated on molybdenum by physical vapour deposition (PVD) and chemical vapour deposition (CVD). The PVD SiC (plasma-assisted ion plating) exhibited a greater thinning rate than the CVD SiC film. Electron probe X-ray microanalysis revealed that the chemical composition of PVD SiC was changed to a composition enriched in silicon by the bombardment, and there was a notable change in its surface morphology. The CVD SiC retained its initial chemical composition with only a small change in its surface morphology. Auger electron spectroscopy indicated that silicon oxide was formed on the surface of PVD SiC by the bombardment. The greater thinning rate and easier change in chemical composition in PVD SiC could be attributed to its readier chemical reaction with oxygen due to its more non-uniform structure and weaker chemical bonding. Oxygen was present as one of the impurities in the argon beam. (Auth.)

  19. Fate of inhaled azodicarbonamide in rats

    International Nuclear Information System (INIS)

    Mewhinney, J.A.; Ayres, P.H.; Bechtold, W.E.; Dutcher, J.S.; Cheng, Y.S.; Bond, J.A.; Medinsky, M.A.; Henderson, R.F.; Birnbaum, L.S.

    1987-01-01

    Azodicarbonamide (ADA) is widely used as a blowing agent in the manufacture of expanded foam plastics, as an aging and bleaching agent in flour, and as a bread dough conditioner. Human exposures have been reported during manufacture as well as during use. Groups of male F344/N rats were administered ADA by gavage, by intratracheal instillation, and by inhalation exposure to determine the disposition and modes of excretion of ADA and its metabolites. At 72 hr following gavage, 30% of the administered ADA was absorbed whereas following intratracheal instillation, absorption was 90%. Comparison between groups of rats exposed by inhalation to ADA to achieve body burdens of 24 or 1230 micrograms showed no significant differences in modes or rates of excretion of [ 14 C]ADA equivalents. ADA was readily converted to biurea under physiological conditions and biurea was the only 14 C-labeled compound present in excreta. [ 14 C]ADA equivalents were present in all examined tissues immediately after inhalation exposure, and clearance half-times on the order of 1 day were evident for all tissues investigated. Storage depots for [ 14 C]ADA equivalents were not observed. The rate of buildup of [ 14 C]ADA equivalents in blood was linearly related to the lung content as measured from rats withdrawn at selected times during a 6-hr inhalation exposure at an aerosol concentration of 25 micrograms ADA/liter. In a study extending 102 days after exposure, retention of [ 14 C]ADA equivalents in tissues was described by a two-component negative exponential function. The results from this study indicate that upon inhalation, ADA is rapidly converted to biurea and that biurea is then eliminated rapidly from all tissues with the majority of the elimination via the urine

  20. Modelling and interpreting the isotopic composition of water vapour in convective updrafts

    Directory of Open Access Journals (Sweden)

    M. Bolot

    2013-08-01

    Full Text Available The isotopic compositions of water vapour and its condensates have long been used as tracers of the global hydrological cycle, but may also be useful for understanding processes within individual convective clouds. We review here the representation of processes that alter water isotopic compositions during processing of air in convective updrafts and present a unified model for water vapour isotopic evolution within undiluted deep convective cores, with a special focus on the out-of-equilibrium conditions of mixed-phase zones where metastable liquid water and ice coexist. We use our model to show that a combination of water isotopologue measurements can constrain critical convective parameters, including degree of supersaturation, supercooled water content and glaciation temperature. Important isotopic processes in updrafts include kinetic effects that are a consequence of diffusive growth or decay of cloud particles within a supersaturated or subsaturated environment; isotopic re-equilibration between vapour and supercooled droplets, which buffers isotopic distillation; and differing mechanisms of glaciation (droplet freezing vs. the Wegener–Bergeron–Findeisen process. As all of these processes are related to updraft strength, particle size distribution and the retention of supercooled water, isotopic measurements can serve as a probe of in-cloud conditions of importance to convective processes. We study the sensitivity of the profile of water vapour isotopic composition to differing model assumptions and show how measurements of isotopic composition at cloud base and cloud top alone may be sufficient to retrieve key cloud parameters.

  1. Modelling and interpreting the isotopic composition of water vapour in convective updrafts

    Science.gov (United States)

    Bolot, M.; Legras, B.; Moyer, E. J.

    2013-08-01

    The isotopic compositions of water vapour and its condensates have long been used as tracers of the global hydrological cycle, but may also be useful for understanding processes within individual convective clouds. We review here the representation of processes that alter water isotopic compositions during processing of air in convective updrafts and present a unified model for water vapour isotopic evolution within undiluted deep convective cores, with a special focus on the out-of-equilibrium conditions of mixed-phase zones where metastable liquid water and ice coexist. We use our model to show that a combination of water isotopologue measurements can constrain critical convective parameters, including degree of supersaturation, supercooled water content and glaciation temperature. Important isotopic processes in updrafts include kinetic effects that are a consequence of diffusive growth or decay of cloud particles within a supersaturated or subsaturated environment; isotopic re-equilibration between vapour and supercooled droplets, which buffers isotopic distillation; and differing mechanisms of glaciation (droplet freezing vs. the Wegener-Bergeron-Findeisen process). As all of these processes are related to updraft strength, particle size distribution and the retention of supercooled water, isotopic measurements can serve as a probe of in-cloud conditions of importance to convective processes. We study the sensitivity of the profile of water vapour isotopic composition to differing model assumptions and show how measurements of isotopic composition at cloud base and cloud top alone may be sufficient to retrieve key cloud parameters.

  2. Modelling and intepreting the isotopic composition of water vapour in convective updrafts

    Science.gov (United States)

    Bolot, M.; Legras, B.; Moyer, E. J.

    2012-08-01

    The isotopic compositions of water vapour and its condensates have long been used as tracers of the global hydrological cycle, but may also be useful for understanding processes within individual convective clouds. We review here the representation of processes that alter water isotopic compositions during processing of air in convective updrafts and present a unified model for water vapour isotopic evolution within undiluted deep convective cores, with a special focus on the out-of-equilibrium conditions of mixed phase zones where metastable liquid water and ice coexist. We use our model to show that a combination of water isotopologue measurements can constrain critical convective parameters including degree of supersaturation, supercooled water content and glaciation temperature. Important isotopic processes in updrafts include kinetic effects that are a consequence of diffusive growth or decay of cloud particles within a supersaturated or subsaturated environment; isotopic re-equilibration between vapour and supercooled droplets, which buffers isotopic distillation; and differing mechanisms of glaciation (droplet freezing vs. the Wegener-Bergeron-Findeisen process). As all of these processes are related to updraft strength, droplet size distribution and the retention of supercooled water, isotopic measurements can serve as a probe of in-cloud conditions of importance to convective processes. We study the sensitivity of the profile of water vapour isotopic composition to differing model assumptions and show how measurements of isotopic composition at cloud base and cloud top alone may be sufficient to retrieve key cloud parameters.

  3. The Investigation of Isotopic Composition of Precipitation and water vapour by Using Air Mass Trajectories and Meteorological Parameters

    International Nuclear Information System (INIS)

    Dirican, A.; Acar, Y.; Demircan, M.

    2002-01-01

    In last century there are so many studies were carried out about stable isotopes of precipitation. The Researchers, study in this field directed to examine origin and transport of water vapour. To investigate the conditions of precipitation formation parallel with climatic changes, stable isotopes using as a powerful tool. So that a project coordinated by IAEA. In this presentation we will give some parts of this project which was carried out in Turkey. First results were obtained for 2001 year. The one of the first result which was obtained in this project is the relation between air temperature and isotopic composition of precipitation collected in Ankara Antalya and Adana station. Second was the observation of temporal variation of stable isotope composition in precipitation and water vapour in relation with water vapour transport. δD and δ 18 O content of atmospheric water vapour examined for January - December 2001 time interval. 27 precipitation event had been examined, starting from endengered place and following to trajectories until to reach Turkey, by using ground level and 500mbar synoptic charts. The observed δD and δ 18 O variations of water vapour is related with the endengered place (Atlantic Ocean, Mediterranean Sea, etc.) of water vapour. The isotopic composition of local precipitation forms by regional meteorological factors. In this study δD and δ 18 O relation of event, daily precipitation and water vapour were defined

  4. Inhaled antibiotics for lower respiratory tract infections: focus on ciprofloxacin.

    Science.gov (United States)

    Serisier, D J

    2012-05-01

    The administration of antibiotics by the inhaled route offers an appealing and logical approach to treating infectious respiratory conditions. Studies in the cystic fibrosis (CF) population have established the efficacy of this therapeutic concept and inhaled antibiotic therapy is now one of the pillars of management in CF. There are now a number of new inhaled antibiotic formulations that have shown impressive preliminary evidence for efficacy in CF and are commencing phase III efficacy studies. Translation of this paradigm into the non-CF bronchiectasis population has proven difficult thus far, apparently due to problems with tolerability of inhaled formulations. Inhaled versions of ciprofloxacin have shown good tolerability and microbiological efficacy in preliminary studies, suggesting that effective inhaled antibiotics are finally on the horizon for this previously neglected patient population. The increased use of long-term inhaled antibiotics for a wider range of non-CF indications presents risks to the broader community of greater antimicrobial resistance development that must be carefully weighed against any demonstrated benefits. Copyright 2012 Prous Science, S.A.U. or its licensors. All rights reserved.

  5. Inhaled Drug Delivery: A Practical Guide to Prescribing Inhaler Devices

    Directory of Open Access Journals (Sweden)

    Pierre Ernst

    1998-01-01

    Full Text Available Direct delivery of medication to the target organ results in a high ratio of local to systemic bioavailability and has made aerosol delivery of respiratory medication the route of choice for the treatment of obstructive lung diseases. The most commonly prescribed device is the pressurized metered dose inhaler (pMDI; its major drawback is the requirement that inspiration and actuation of the device be well coordinated. Other requirements for effective drug delivery include an optimal inspiratory flow, a full inspiration from functional residual capacity and a breath hold of at least 6 s. Available pMDIs are to be gradually phased out due to their use of atmospheric ozone-depleting chlorofluorocarbons (CFCs as propellants. Newer pMDI devices using non-CFC propellants are available; preliminary experience suggests these devices greatly increase systemic bioavailability of inhaled corticosteroids. The newer multidose dry powder inhalation devices (DPIs are breath actuated, thus facilitating coordination with inspiration, and contain fewer ingredients. Furthermore, drug delivery is adequate even at low inspired flows, making their use appropriate in almost all situations. Equivalence of dosing among different devices for inhaled corticosteroids will remain imprecise, requiring the physician to adjust the dose of medication to the lowest dose that provides adequate control of asthma. Asthma education will be needed to instruct patients on the effective use of the numerous inhalation devices available.

  6. Evaporation of a volatile organic compound in a hygroscopic soil - influence of the airflow and its VOC vapour saturation

    OpenAIRE

    Naon , Bétaboalé; Benet , Jean-Claude; Cousin , Bruno; Cherblanc , Fabien; Chammari , Ali

    2013-01-01

    International audience; This article presents an experimental and theoretical study of VOC volatilization in soil during a decontamination process by vapour extraction or venting. A phase change law is proposed in the case of a sandy-silty soil when the convective gaseous phase is vapour-charged. A simple experimental method for analyzing the phase change is presented. Finally, an efficiency coefficient is introduced to quantify the contribution of airflow velocity on venting.

  7. A static analytical apparatus for vapour pressures and (vapour + liquid) phase equilibrium measurements with an internal stirrer and view windows

    International Nuclear Information System (INIS)

    Guo, Hao; Gong, Maoqiong; Dong, Xueqiang; Wu, Jianfeng

    2014-01-01

    Highlights: • A new static analytical apparatus for vapour pressures and VLE data was designed. • The {R600a + R245fa} system was selected as a verification system. • Correlation of VLE data was made using PRvdWs and PRHVNRTL model. • Good agreement can be found with the literature data. - Abstract: A new static analytical apparatus for reliable vapour pressures and (vapour + liquid) equilibrium data of small-scale cell (≈150 mL) with internal stirrer and view windows was designed. In this work, the compositions of the phases were analyzed by a gas chromatograph connected on-line with TCD detectors. The operating pressure ranges from (0 to 3000) kPa, and the operating temperature range from (293 to 400) K. Phase equilibrium data for previously reported systems were first measured to test the credibility of the newly developed apparatus. The test included vapour pressure of 1,1,1,3,3-pentafluoropropane (R245fa) and isobutane (R600a), VLE of the (R600a + R245fa) system from T = (293.150 to 343.880) K. The measured VLE data are regressed with thermodynamic models using Peng–Robinson EoS with two different models, viz. the van der Waals mixing rule, and the Huron–Vidal mixing rule utilising the non-random two-liquid activity coefficient model. Thermodynamic consistency testing is also performed for the newly measured experimental data

  8. Thermodynamic and kinetic studies in the systems alkali chloride-zinconium (or hafnium) tetrachloride: Part I. Vapour pressure measurements over hexachloro compounds and use of vapour pressure data in fractional decomposition

    International Nuclear Information System (INIS)

    Ray, H.S.; Bhat, B.G.; Reddy, G.S.; Biswas, A.K.

    1978-01-01

    A molten tin isoteniscope has been used to measure the vapour pressures over ZrCl 4 , HfCl 4 and the hexachlore zirconates (M 2 ZrCl 6 ) and the hexachloro hafnates (M 2 HfCl 6 ) of four alkali metals (M = Na,K,Rb,Cs). The method of preparation of these compounds and the effect of small amounts of residual alkali chlorides on the their vapour pressure are discussed. The pressure-temperature plots are examined in the light of some theoretical postulates. A scheme for separation of hafnium from zirconoium by multistage fractional decomposition of the hexachlore compounds of any alkali metal is described. The scheme, which is analogous to rectification in liquid-vapour systems, employs a countercurrent flow of Zr(Hf)Cl 4 in a gas stream and a moving bed of alkali chlorides. The separation is based on the difference in the dissociation equilibrium for zirconium and hafnium compounds. Stage calculations for such a scheme and the main conclusions of a computational work are presented. (author)

  9. Characterisation and vapour sensing properties of spin coated thin films of anthracene labelled PMMA polymer

    Energy Technology Data Exchange (ETDEWEB)

    Capan, I., E-mail: inci.capan@gmail.com [Balikesir University, Faculty of Art and Sciences, Department of Physics, Cagis Campus, 10145 Balikesir (Turkey); Tarimci, C., E-mail: Celik.Tarimci@eng.ankara.edu.tr [Ankara University, Faculty of Engineering, Department of Engineering Physics, 06100, Ankara (Turkey); Erdogan, M., E-mail: merdogan@balikesir.edu.tr [Balikesir University, Faculty of Art and Sciences, Department of Physics, Cagis Campus, 10145 Balikesir (Turkey); Hassan, A.K., E-mail: A.Hassan@shu.ac.uk [Materials and Engineering Research Institute, Sheffield Hallam University, Sheaf Building, Pond Street, Sheffield S1 1WB (United Kingdom)

    2009-05-05

    In the present article thin films of poly (methyl methacrylate) (PMMA) polymer labelled with anthracene (Ant-PMMA) prepared by spin coating are characterised by UV-visible spectroscopy, surface plasmon resonance (SPR), spectroscopic ellipsometry (SE) and Atomic Force Microscopy (AFM) and their organic vapour sensing properties are investigated. Ant-PMMA films' thickness are determined by performing theoretical fitting to experimental data measured using SPR and SE. Results obtained show that the spin-cast films are of good uniformity with an average thickness of 6-8 nm. Organic vapour sensing properties are studied using SPR technique during exposures to different volatile organic compounds (VOCs). Ant-PMMA films' response to the selected VOCs has been examined in terms of solubility parameters and molar volumes of the solvents, and the films were found to be largely sensitive to benzene vapour compared to other studied analytes.

  10. Characterisation and vapour sensing properties of spin coated thin films of anthracene labelled PMMA polymer

    International Nuclear Information System (INIS)

    Capan, I.; Tarimci, C.; Erdogan, M.; Hassan, A.K.

    2009-01-01

    In the present article thin films of poly (methyl methacrylate) (PMMA) polymer labelled with anthracene (Ant-PMMA) prepared by spin coating are characterised by UV-visible spectroscopy, surface plasmon resonance (SPR), spectroscopic ellipsometry (SE) and Atomic Force Microscopy (AFM) and their organic vapour sensing properties are investigated. Ant-PMMA films' thickness are determined by performing theoretical fitting to experimental data measured using SPR and SE. Results obtained show that the spin-cast films are of good uniformity with an average thickness of 6-8 nm. Organic vapour sensing properties are studied using SPR technique during exposures to different volatile organic compounds (VOCs). Ant-PMMA films' response to the selected VOCs has been examined in terms of solubility parameters and molar volumes of the solvents, and the films were found to be largely sensitive to benzene vapour compared to other studied analytes.

  11. Chemical vapour deposition of silicon under reduced pressure in a hot-wall reactor: Equilibrium and kinetics

    International Nuclear Information System (INIS)

    Langlais, F.; Hottier, F.; Cadoret, R.

    1982-01-01

    Silicon chemical vapour deposition (SiH 2 Cl 2 /H 2 system), under reduced pressure conditions, in a hot-wall reactor, is presented. The vapour phase composition is assessed by evaluating two distinct equilibria. The homogeneous equilibrium , which assumes that the vapour phase is not in equilibrium with solid silicon, is thought to give an adequate description of the vapour phase in the case of low pressure, high gas velocities, good temperature homogeneity conditions. A comparison with heterogeneous equilibrium enables us to calculate the supersaturation so evidencing a highly irreversible growth system. The experimental determination of the growth rates reveals two distinct temperature ranges: below 1000 0 C, polycrystalline films are usually obtained with a thermally activated growth rate (+40 kcal mole -1 ) and a reaction order, with respect to the predominant species SiCl 2 , close to one; above 1000 0 C, the films are always monocrystalline and their growth rate exhibits a much lower or even negative activation energy, the reaction order in SiCl 2 remaining about one. (orig.)

  12. Evaluation of a novel educational strategy, including inhaler-based reminder labels, to improve asthma inhaler technique.

    Science.gov (United States)

    Basheti, Iman A; Armour, Carol L; Bosnic-Anticevich, Sinthia Z; Reddel, Helen K

    2008-07-01

    To evaluate the feasibility, acceptability and effectiveness of a brief intervention about inhaler technique, delivered by community pharmacists to asthma patients. Thirty-one pharmacists received brief workshop education (Active: n=16, CONTROL: n=15). Active Group pharmacists were trained to assess and teach dry powder inhaler technique, using patient-centered educational tools including novel Inhaler Technique Labels. Interventions were delivered to patients at four visits over 6 months. At baseline, patients (Active: 53, CONTROL: 44) demonstrated poor inhaler technique (mean+/-S.D. score out of 9, 5.7+/-1.6). At 6 months, improvement in inhaler technique score was significantly greater in Active cf. CONTROL patients (2.8+/-1.6 cf. 0.9+/-1.4, p<0.001), and asthma severity was significantly improved (p=0.015). Qualitative responses from patients and pharmacists indicated a high level of satisfaction with the intervention and educational tools, both for their effectiveness and for their impact on the patient-pharmacist relationship. A simple feasible intervention in community pharmacies, incorporating daily reminders via Inhaler Technique Labels on inhalers, can lead to improvement in inhaler technique and asthma outcomes. Brief training modules and simple educational tools, such as Inhaler Technique Labels, can provide a low-cost and sustainable way of changing patient behavior in asthma, using community pharmacists as educators.

  13. The thermotidal exciting function for water vapour absorption of solar radiation

    Directory of Open Access Journals (Sweden)

    M. BONAFEDE

    1976-06-01

    Full Text Available The thermotidal exciting function J is considered, for
    the absorption of solar radiation by water vapour, according to the model
    derived by Siebert. The Mugge-Moller formula for water vapour absorption
    is integrated numerically, using experimental data for the water vapour
    concentration in the troposphere and the stratosphere. It appears that
    Siebort's formula is a reasonable approximation at low tropospheric levels
    but it dramatically overestimates the water vapour thermotidal heating
    in the upper troposphere and in the stratosphere. It seems thus possible
    that, if the correct vertical profile is employed for J , the amplitudes and
    phases of the diurnal temperature oscillations and of the tidal wind speeds
    may suffer significant changes from those previously calculated and possibly explain the three hours delay of the observed phases from the computed values.

  14. A review on the recent development of solar absorption and vapour compression based hybrid air conditioning with low temperature storage

    Directory of Open Access Journals (Sweden)

    Noor D. N.

    2016-01-01

    Full Text Available Conventional air conditioners or vapour compression systems are main contributors to energy consumption in modern buildings. There are common environmental issues emanating from vapour compression system such as greenhouse gas emission and heat wastage. These problems can be reduced by adaptation of solar energy components to vapour compression system. However, intermittence input of daily solar radiation was the main issue of solar energy system. This paper presents the recent studies on hybrid air conditioning system. In addition, the basic vapour compression system and components involved in the solar air conditioning system are discussed. Introduction of low temperature storage can be an interactive solution and improved economically which portray different modes of operating strategies. Yet, very few studies have examined on optimal operating strategies of the hybrid system. Finally, the findings of this review will help suggest optimization of solar absorption and vapour compression based hybrid air conditioning system for future work while considering both economic and environmental factors.

  15. Inhalant Dependence and its Medical Consequences

    Directory of Open Access Journals (Sweden)

    Mehmet Hamid Boztaş

    2010-12-01

    Full Text Available The term of inhalants is used for matters easily vapors. Inhalants are preferred for rapid, positive reinforcement and mild high effects. Products including inhalants are cheap, accessible, legal substances and are prevalently used in community. The prevalence of inhalant use in secondary schools in Turkey is about 5.1%. Inhalant substance dependence is generally observed within 14-15 age group. Age at first use could be as low as 5 to 6 years of age. Substance dependence is more probable in adults working in substance existing places. Inhalant usage is common in disadvantaged groups, children living in street, people with history of crimes, prison, depression, suicide, antisocial attitudes and conflict of family, history of abuse, violence and any other drug dependence and isolated populations. Inhalants are absorbed from lungs, after performing their quick and short effect metabolized by cytochrom P450 enzyme system except inhalant nitrites group which has a depressing effect like alcohol. In chronic use general atrophy, ventricular dilatation and wide sulcus were shown in cerebrum, cerebellum and pons by monitoring brain. Defects are mostly in periventricular, subcortical regions and in white matter. Demyelinization, hyperintensity, callosal slimming and wearing off in white and gray matter margins was also found. Ravages of brain shown by brain monitorisation are more and serious in inhalant dependence than in other dependences. It is important to decrease use of inhalants. Different approaches should be used for subcultures and groups in prevention. Prohibiting all the matters including inhalant is not practical as there are too many substances including inhalants. Etiquettes showing harmful materials can be used but this approach can also lead the children and adolescents recognize these substances easily.. Despite determintal effects of inhalant dependence, there are not yet sufficient number of studies conducted on prevention and

  16. Pulmonary CT findings in acute mercury vapour exposure

    Energy Technology Data Exchange (ETDEWEB)

    Hashimoto, Manabu; Sato, Kimihiko; Heianna, Jyouiti; Hirano, Yoshinori; Omachi, Kohiti; Izumi, Jyunichi; Watarai, Jiro

    2001-01-01

    AIM: We describe the pulmonary computed tomography (CT) findings in acute mercury poisoning. MATERIALS AND METHODS: Initial (n= 8) and follow-up (n= 6) chest CT examinations in eight patients exposed to mercury vapour while cutting pipes in a sulphuric acid plant were reviewed. Of the eight patients, two were asymptomatic and had normal CT results, two were asymptomatic but had abnormalities on CT, and four had both acute symptoms and positive CT results. The patients were all men whose ages ranged from 37 to 54 years (mean, 49 years). RESULTS: Poorly defined nodules were present in five of six patients with positive CT findings, present alone in two patients or as part of a mixed pattern in three. They were random in distribution. Alveolar consolidation (n= 3) and areas of ground-glass opacity (n= 4) were observed and were more prominent in the most severely affected patients with the highest blood and urine level of mercury, predominantly in the upper and/or middle zone. These abnormal findings on CT resolved with (n= 1) or without (n= 5) steroid therapy. Pathological findings (n= 1) demonstrated acute interstitial changes predominantly with oedema. CONCLUSION: We report CT findings in eight patients acutely exposed to mercury vapour. The pulmonary injury was reversible on CT in these cases. Hashimoto, M. (2001)

  17. Microsphere formation in droplets using antisolvent vapour precipitation technique

    OpenAIRE

    Chew, Sean Jun Liang

    2017-01-01

    In previous studies, the antisolvent vapour precipitation method has been proven to produce uniformly sized lactose microspheres (1.0 µm) from a single droplet (1.2 mm diameter) at atmospheric pressure. These types of particles have potential applications in the pharmaceutical industry, especially due to their high dissolution rate. This project looked into the possibility of using antisolvent vapour precipitation to produce microspheres from finely atomised droplets. Microspheres in the sub-...

  18. Antifungal Activity of Clove Essential Oil and its Volatile Vapour Against Dermatophytic Fungi

    OpenAIRE

    Chee, Hee Youn; Lee, Min Hee

    2007-01-01

    Antifungal activities of clove essential oil and its volatile vapour against dermatophytic fungi including Candida albicans, Epidermophyton floccosum. Microsporum audouinii, Trichophyton mentagrophytes, and Trichophyton rubrum were investigated. Both clove essential oil and its volatile vapour strongly inhibit spore germination and mycelial growth of the dermatophytic fungi tested. The volatile vapour of clove essential oil showed fungistatic activity whereas direct application of clove essen...

  19. Film boiling heat transfer and vapour film collapse for various geometries

    International Nuclear Information System (INIS)

    Jouhara, H.I.; Axcell, B.P.

    2005-01-01

    Full text of publication follows: Film boiling heat transfer has application to the safe operation of water-cooled nuclear reactors under fault conditions and it has been studied using nickel-plated copper specimens in transient and steady state experiments. In the transient tests the specimens were held in a water flow; in the steady state investigation a specimen was mounted in an essentially quiescent pool of water. The transient investigation was conducted on two spheres with different diameters, two cylindrical specimens of different lengths in parallel flow, a short cylinder in cross flow and two flat plates with different lengths. The heat transfer coefficient, vapour film thickness (which was estimated from the heat transfer coefficient) and heat flux followed a similar behaviour with changing experimental conditions for all specimens studied. The heat transfer coefficient increased and the vapour film thickness and heat flux decreased as the specimen temperature decreased. As the water subcooling increased the heat transfer coefficient and the heat flux increased while the vapour film thickness decreased. The water velocity was found to have little influence on the film boiling heat transfer results except for the short cylinder in cross flow. The sphere diameter was found to affect the heat transfer results; the heat transfer coefficient and the heat flux were larger, for the larger sphere. No significant effect of the cylinder length on the heat transfer data was observed. However, the heat transfer coefficient was higher (and the average vapour film thinner) for the longer plate than for the shorter plate. Three vapour/liquid interface types were observed namely: 'smooth', 'rippled' and 'turbulent' depending largely on specimen and water temperatures. For all specimens, the maximum heat transfer coefficient, minimum heat flux and minimum film boiling temperature, occurring just before vapour film collapse, were found to increase as the water subcooling

  20. First Townsend coefficient of organic vapour in avalanche counters

    International Nuclear Information System (INIS)

    Sernicki, J.

    1990-01-01

    A new concept is presented in the paper for implementing the proven method of determining the first Townsend coefficient (α) of gases using an avalanche counter. The A and B gas constants, interrelated by the expression α/p=A exp[-B/(K/p)], are analyzed. Parallel-plate avalanche counters (PPAC) with an electrode spacing d from 0.1 to 0.4 cm have been employed for the investigation, arranged to register low-energy alpha particles at n-heptane vapour pressures of p≥5 Torr. An in-depth discussion is given, covering the veracity and the behaviour vs K/p, of the n-heptane A and B constants determined at reduced electric-field intensity values ranging from 173.5 to 940 V/cm Torr; the constants have been found to depend upon d. The results of the investigation are compared to available data of the α coefficient of organic vapours used in avalanche counters. The PPAC method of determining α reveals some imperfections at very low values of the pd product. (orig.)

  1. Interactions of fission product vapours with aerosols

    Energy Technology Data Exchange (ETDEWEB)

    Benson, C G; Newland, M S [AEA Technology, Winfrith (United Kingdom)

    1996-12-01

    Reactions between structural and reactor materials aerosols and fission product vapours released during a severe accident in a light water reactor (LWR) will influence the magnitude of the radiological source term ultimately released to the environment. The interaction of cadmium aerosol with iodine vapour at different temperatures has been examined in a programme of experiments designed to characterise the kinetics of the system. Laser induced fluorescence (LIF) is a technique that is particularly amenable to the study of systems involving elemental iodine because of the high intensity of the fluorescence lines. Therefore this technique was used in the experiments to measure the decrease in the concentration of iodine vapour as the reaction with cadmium proceeded. Experiments were conducted over the range of temperatures (20-350{sup o}C), using calibrated iodine vapour and cadmium aerosol generators that gave well-quantified sources. The LIF results provided information on the kinetics of the process, whilst examination of filter samples gave data on the composition and morphology of the aerosol particles that were formed. The results showed that the reaction of cadmium with iodine was relatively fast, giving reaction half-lives of approximately 0.3 s. This suggests that the assumption used by primary circuit codes such as VICTORIA that reaction rates are mass-transfer limited, is justified for the cadmium-iodine reaction. The reaction was first order with respect to both cadmium and iodine, and was assigned as pseudo second order overall. However, there appeared to be a dependence of aerosol surface area on the overall rate constant, making the precise order of the reaction difficult to assign. The relatively high volatility of the cadmium iodide formed in the reaction played an important role in determining the composition of the particles. (author) 23 figs., 7 tabs., 22 refs.

  2. Interactions of fission product vapours with aerosols

    International Nuclear Information System (INIS)

    Benson, C.G.; Newland, M.S.

    1996-01-01

    Reactions between structural and reactor materials aerosols and fission product vapours released during a severe accident in a light water reactor (LWR) will influence the magnitude of the radiological source term ultimately released to the environment. The interaction of cadmium aerosol with iodine vapour at different temperatures has been examined in a programme of experiments designed to characterise the kinetics of the system. Laser induced fluorescence (LIF) is a technique that is particularly amenable to the study of systems involving elemental iodine because of the high intensity of the fluorescence lines. Therefore this technique was used in the experiments to measure the decrease in the concentration of iodine vapour as the reaction with cadmium proceeded. Experiments were conducted over the range of temperatures (20-350 o C), using calibrated iodine vapour and cadmium aerosol generators that gave well-quantified sources. The LIF results provided information on the kinetics of the process, whilst examination of filter samples gave data on the composition and morphology of the aerosol particles that were formed. The results showed that the reaction of cadmium with iodine was relatively fast, giving reaction half-lives of approximately 0.3 s. This suggests that the assumption used by primary circuit codes such as VICTORIA that reaction rates are mass-transfer limited, is justified for the cadmium-iodine reaction. The reaction was first order with respect to both cadmium and iodine, and was assigned as pseudo second order overall. However, there appeared to be a dependence of aerosol surface area on the overall rate constant, making the precise order of the reaction difficult to assign. The relatively high volatility of the cadmium iodide formed in the reaction played an important role in determining the composition of the particles. (author) 23 figs., 7 tabs., 22 refs

  3. Steam/water separation device for drying a wet vapour

    International Nuclear Information System (INIS)

    Sundheimer, P.

    1986-01-01

    The aim of the present invention is to dry a wet vapour which flows up to the device. The device has at least a group of steam dryer elements in a zone in which there is a vertical apertured panel; this vertical apertured panel is a metal grille with baffles the inlet steam flow to make it horizontal or slightly inclined to the bottom. The invention applies more particularly, to PWR steam generators [fr

  4. Antifungal activity of clove essential oil and its volatile vapour against dermatophytic fungi.

    Science.gov (United States)

    Chee, Hee Youn; Lee, Min Hee

    2007-12-01

    Antifungal activities of clove essential oil and its volatile vapour against dermatophytic fungi including Candida albicans, Epidermophyton floccosum. Microsporum audouinii, Trichophyton mentagrophytes, and Trichophyton rubrum were investigated. Both clove essential oil and its volatile vapour strongly inhibit spore germination and mycelial growth of the dermatophytic fungi tested. The volatile vapour of clove essential oil showed fungistatic activity whereas direct application of clove essential oil showed fungicidal activity.

  5. Electron collision cross section sets of TMS and TEOS vapours

    Science.gov (United States)

    Kawaguchi, S.; Takahashi, K.; Satoh, K.; Itoh, H.

    2017-05-01

    Reliable and detailed sets of electron collision cross sections for tetramethylsilane [TMS, Si(CH3)4] and tetraethoxysilane [TEOS, Si(OC2H5)4] vapours are proposed. The cross section sets of TMS and TEOS vapours include 16 and 20 kinds of partial ionization cross sections, respectively. Electron transport coefficients, such as electron drift velocity, ionization coefficient, and longitudinal diffusion coefficient, in those vapours are calculated by Monte Carlo simulations using the proposed cross section sets, and the validity of the sets is confirmed by comparing the calculated values of those transport coefficients with measured data. Furthermore, the calculated values of the ionization coefficient in TEOS/O2 mixtures are compared with measured data to confirm the validity of the proposed cross section set.

  6. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... KB] Using a metered dose inhaler (inhaler in mouth) Your browser does not support iframes Using a metered dose inhaler (inhaler in mouth) [PDF – 370 KB] Your browser does not support ...

  7. Inhalation Toxicology Research Institute. Annual report, October 1, 1981-September 30, 1982

    International Nuclear Information System (INIS)

    Snipes, M.B.; Marshall, T.C.; Martinez, B.S.

    1982-12-01

    Studies are presented of the effect on man of airborne particulates and gaseous emissions associated with the production of energy. Included in the report from the Inhalation Toxicology Research Institute are papers on: (1) the physical and chemical characterization of energy technology aerosols; (2) laboratory studies of aerosol generation and characterization; (3) in vitro predictors of toxicity; (4) disposition and fate of inhaled materials; (5) dose-response relationships for inhaled radionuclides; (6) dose-response relationships for inhaled chemical toxicants; (7) biological factors which influence dose-response relationships; and (8) risk assessment

  8. Effects of a single inhalative exposure to formaldehyde on the open field behavior of mice.

    Science.gov (United States)

    Malek, Fathi A; Möritz, Klaus-Uwe; Fanghänel, Jochen

    2004-02-01

    The effects of formaldehyde on the explorative behavior and locomotor activity of mice after a single inhalative exposure were examined in an open field. Adult male mice were exposed to approximately 1.1 ppm, 2.3 ppm, or 5.2 ppm formaldehyde vapour for 2 hours and the open field test was carried out two hours after the end of exposure (trial 1) and repeated 24 hours thereafter (trial 2). The following behavioral parameters were quantitatively examined: numbers of crossed floor squares (inner, peripheral, total), sniffing, grooming, rearing, climbing, and incidence of fecal boli. The results of the first trial revealed that the motion activity was significantly reduced in all exposed groups. In the 1.1 ppm group, the frequency of rearing was reduced and that of floor sniffing increased. The exposure to the two higher formaldehyde concentrations caused a significant decrease in total numbers of floor squares crossed by the subjects, air sniffing, and rearing. The open field test on the next day (trial 2) showed that the frequencies of floor sniffing, grooming, and rearing in all formaldehyde groups were significantly altered. In the 2.5 ppm group, an increased incidence of fecal boli was observed. From the results obtained, we conclude that the exposure of male mice to formaldehyde vapour affects their locomotor and explorative activity in the open field, and that some open field parameters are still altered in the exposed animals even after 24 hours.

  9. Impact of major volcanic eruptions on stratospheric water vapour

    Directory of Open Access Journals (Sweden)

    M. Löffler

    2016-05-01

    Full Text Available Volcanic eruptions can have a significant impact on the Earth's weather and climate system. Besides the subsequent tropospheric changes, the stratosphere is also influenced by large eruptions. Here changes in stratospheric water vapour after the two major volcanic eruptions of El Chichón in Mexico in 1982 and Mount Pinatubo on the Philippines in 1991 are investigated with chemistry–climate model simulations. This study is based on two simulations with specified dynamics of the European Centre for Medium-Range Weather Forecasts Hamburg – Modular Earth Submodel System (ECHAM/MESSy Atmospheric Chemistry (EMAC model, performed within the Earth System Chemistry integrated Modelling (ESCiMo project, of which only one includes the long-wave volcanic forcing through prescribed aerosol optical properties. The results show a significant increase in stratospheric water vapour induced by the eruptions, resulting from increased heating rates and the subsequent changes in stratospheric and tropopause temperatures in the tropics. The tropical vertical advection and the South Asian summer monsoon are identified as sources for the additional water vapour in the stratosphere. Additionally, volcanic influences on tropospheric water vapour and El Niño–Southern Oscillation (ENSO are evident, if the long-wave forcing is strong enough. Our results are corroborated by additional sensitivity simulations of the Mount Pinatubo period with reduced nudging and reduced volcanic aerosol extinction.

  10. Electrostatic Properties of Particles for Inhalation

    OpenAIRE

    Rowland, Martin

    2015-01-01

    Dry powder inhalers (DPIs) and pressurised metered dose inhalers (pMDIs) aredevices used to deliver therapeutic agents to the lungs. Typically, inhaled activepharmaceutical ingredients (APIs) are electrically resistive materials and are prone toaccumulating electrostatic charge. The build-up of charge on inhaled therapeutics hastraditionally been viewed as a nuisance as it may result in problems such as weighingerrors, agglomeration, adhesion to surfaces and poor flow. Energetic processing st...

  11. The water vapour flux above Switzerland and its role in the August 2005 extreme precipitation and flooding

    Energy Technology Data Exchange (ETDEWEB)

    N' Dri Koffi, Ernest; Maetzler, Christian [Bern Univ. (Switzerland). Inst. of Applied Physics; Graham, Edward [Bern Univ. (Switzerland). Inst. of Applied Physics; University of the Highlands and Islands, Stornoway, Scotland (United Kingdom). Lews Castle College

    2013-10-15

    The water budget approach is applied to an atmospheric box above Switzerland (hereafter referred to as the 'Swiss box') to quantify the atmospheric water vapour flux using ECMWF ERA-Interim reanalyses. The results confirm that the water vapour flux through the Swiss box is highly temporally variable, ranging from 1 to 5 x 10{sup 7} kg/s during settled anticyclonic weather, but increasing in size by a factor of ten or more during high speed currents of water vapour. Overall, Switzerland and the Swiss box 'import' more water vapour than it 'exports', but the amount gained remains only a small fraction (1% to 5%) of the total available water vapour passing by. High inward water vapour fluxes are not necessarily linked to high precipitation episodes. The water vapour flux during the August 2005 floods, which caused severe damage in central Switzerland, is examined and an assessment is made of the computed water vapour fluxes compared to high spatio-temporal rain gauge and radar observations. About 25% of the incoming water vapour flux was stored in Switzerland. The computed water vapour fluxes from ECMWF data compare well with the mean rain gauge observations and the combined rain-gauge radar precipitation products. (orig.)

  12. Inhaled americium dioxide

    International Nuclear Information System (INIS)

    Park, J.F.

    1982-01-01

    This project includes experiments to determine the effects of Zn-DTPA therapy on the retention, translocation and biological effects of inhaled 241 AmO 2 . Beagle dogs that received inhalation exposure to 241 AmO 2 developed leukopenia, clincial chemistry changes associated with hepatocellular damage, and were euthanized due to respiratory insufficiency caused by radiation pneumonitis 120 to 131 days after pulmonary deposition of 22 to 65 μCi 241 Am. Another group of dogs that received inhalation exposure to 241 AmO 2 and were treated daily with Zn-DTPA had initial pulmonary deposition of 19 to 26 μCi 241 Am. These dogs did not develop respiratory insufficiency, and hematologic and clinical chemistry changes were less severe than in the non-DTPA-treated dogs

  13. The ratio DT/μ for electrons in water vapour at 294 K

    International Nuclear Information System (INIS)

    Elford, M.T.

    1995-01-01

    The ratio D T /μ for electrons in water vapour (294 K) has been measured by the Townsend-Huxley method as a function of E/N (where E is the electric field strength and N the gas number density) at vapour pressures ranging from 0.103 to 0.413 kPa. For E/N ≤ 30 Td, where attachment and ionisation may be neglected, the values are found to be independent of vapour pressure and of the current ratio relation used to derive D T /μ values from the measured current ratios. The uncertainty of these D T /μ values is estimated to be T /μ measured at E/N > 30 Td were found to be strongly pressure dependent, the strength and sign of the dependence depending on E/N and the current ratio relation used. Since extrapolation to infinite pressure at each E/N value did not give the same value of D T /μ, it has not been possible to derive reliable D T /μ values for this higher E/N range. Possible causes of the observed pressure dependences are discussed. The present data are in good agreement with the values predicted by Ness and Robson for values of E/N ≤ 24 Td. 17 refs., 1 tab., 5 figs

  14. The effect of smoking status on burn inhalation injury mortality.

    Science.gov (United States)

    Knowlin, Laquanda; Stanford, Lindsay; Cairns, Bruce; Charles, Anthony

    2017-05-01

    Three factors that effect burn mortality are age, total body surface of burn (TBSA), and inhalation injury. Of the three, inhalation injury is the strongest predictor of mortality thus its inclusion in the revised Baux score (age+TBSA+17* (inhalation injury, 1=yes, 0=no)). However, the weighted contribution of specific comorbidities such as smoker status on mortality has traditionally not been accounted for nor studied in this subset of burn patients. We therefore sought to examine the impact of current tobacco and/or marijuana smoking in patients with inhalation injury. A retrospective analysis of patients admitted to a regional burn center from 2002 to 2012. Independent variables analyzed included basic demographics, burn mechanism, presence of inhalation injury, TBSA, pre-existing comorbidities, and smoker status. Bivariate analysis was performed and logistic regression modeling using significant variables was utilized to estimate odds of mortality. There were a total of 7640 patients over the study period. 7% (n=580) of the burn cohort with inhalation injury were included in this study. In-hospital burn mortality for inhalation injury patients was 23%. Current smokers (20%) included cigarette smokers and marijuana users, 19% and 3%, respectively. Preexisting respiratory disease (17%) was present in 36% of smokers compared to 13% of non-smokers (psmoke inhalation injury. Future prospective studies in human and/or animal models are needed to confirm these findings. Copyright © 2016 Elsevier Ltd and ISBI. All rights reserved.

  15. Does inhalation injury predict mortality in burns patients or require redefinition?

    Directory of Open Access Journals (Sweden)

    Youngmin Kim

    Full Text Available Inhalation injury is known to be an important factor in predicting mortality in burns patients. However, the diagnosis is complicated by the heterogeneous presentation and inability to determine the severity of inhalation injury. The purpose of this study was to identify clinical features of inhalation injury that affect mortality and the values that could predict the outcome more precisely in burns patients with inhalation injury. This retrospective observational study included 676 burns patients who were over 18 years of age and hospitalized in the Burns Intensive Care Unit between January 2012 and December 2015. We analyzed variables that are already known to be prognostic factors (age, percentage of total body surface area (%TBSA burned, and inhalation injury and factors associated with inhalation injury (carboxyhemoglobin and PaO2/FiO2 [PF] ratio by univariate and multivariate logistic regression. Age group (odds ratio [OR] 1.069, p<0.001, %TBSA burned (OR 1.100, p<0.001, and mechanical ventilation (OR 3.774, p<0.001 were identified to be significant predictive factors. The findings for presence of inhalation injury, PF ratio, and carboxyhemoglobin were not statistically significant in multivariate logistic regression. Being in the upper inhalation group, the lower inhalation group, and having a PF ratio <100 were identified to be significant predictors only in univariate logistic regression analysis (OR 4.438, p<0.001; OR 2.379, p<0.001; and OR 2.765, p<0.001, respectively. History and physical findings are not appropriate for diagnosis of inhalation injury and do not predict mortality. Mechanical ventilation should be recognized as a risk factor for mortality in burns patients with inhalation injury.

  16. Installation for vacuum vapour deposition of nickel, more particularly for manufacturing neutron guides

    International Nuclear Information System (INIS)

    Samuel, F.

    1986-01-01

    The present invention proposes an installation for vacuum vapour deposition of Ni of the type including in a vacuum chamber a device for heating a mass of at least one Ni isotope to be evaporated, and a surface to be covered with deposited Ni facing the heater, is claimed, in which the heater includes a ribbon of W conformed in a middle part into a container in which is placed a refractory crucible in which is placed the Ni to be evaporated, and adapted to be connected at two terminal zones to an electrical circuit. The crucible is Al203. The invention finds an application in neutron guide fabrication, more particularly for Ni58 vapour deposition on the surfaces of the neutron guide [fr

  17. Factors affecting release of ethanol vapour in active modified atmosphere packaging systems for horticultural products

    Directory of Open Access Journals (Sweden)

    Weerawate Utto

    2014-04-01

    Full Text Available The active modified atmosphere packaging (active MAP system , which provides interactive postharvest control , using ethanol vapour controlled release, is one of the current interests in the development of active packaging for horticultural products. A number of published research work have discussed the relationship between the effectiveness of ethanol vapour and its concentration in the package headspace, including its effect on postharvest decay and physiological controls. This is of importance because a controlled release system should release and maintain ethanol vapour at effective concentrations during the desired storage period. A balance among the mass transfer processes of ethanol vapour in the package results in ethanol vapour accumulation in the package headspace. Key factors affecting these processes include ethanol loading, packaging material, packaged product and storage environment (temperature and relative h umidity. This article reviews their influences and discusses future work required to better understand their influences on ethanol vapour release and accumulations in active MAP.

  18. Aspects of the dispersion of denser-than-air vapours relevant to gas cloud explosions

    International Nuclear Information System (INIS)

    Wheatley, C.J.; Webber, D.M.

    1985-01-01

    The essential aim of the study presented here is to improve upon the understanding and prediction of the atmospheric dispersion of denser-than-air vapours, and thereby reduce the uncertainties in predicting hazards which might arise from the accidental release of a dense, flammable vapour cloud. In the first phase of the study, models for dispersion in the atmosphere of denser-than-air vapours are reviewed. It is found that a significant source of uncertainty in predictions of all models is the calculation of dilution caused by turbulence. This is due to spreading and stratification caused by the excess density of the cloud and to the interaction of the cloud motion with the ambient flow field. These effects lead to a complex field of turbulence. An additional, significant source of uncertainty is found to be present in '3D' models due to the use of coarse computational grids. A number of experimental tests are proposed which permit fundamental discrimination between the models with the object of reducing uncertainties. In the second phase of the study, a new 'box' model is proposed (A 'box' model is one in which only gross properties of the flow are predicted). All sources of turbulence are included in a way consistent with laboratory studies of entrainment in stratified flows. The prescribed concentration distribution models the initial 'mixed layer'/'gravity spreading' phase and the final 'passive' phase of dispersion with a smooth transition between the two. In the third phase of the study, implications of dispersion of denser-than-air flammable vapour clouds in open terrain for flame speeds following ignition by a weak source are assessed. It is concluded that flame speeds sufficient to cause significant overpressures cannot occur in unobstructed terrain. (author)

  19. Inhalants

    Science.gov (United States)

    ... Alcohol Club Drugs Cocaine Fentanyl Hallucinogens Inhalants Heroin Marijuana MDMA (Ecstasy/Molly) Methamphetamine Opioids Over-the-Counter Medicines Prescription Medicines Steroids (Anabolic) Synthetic Cannabinoids (K2/Spice) Synthetic Cathinones (Bath Salts) Tobacco/ ...

  20. Organic Vapour Sensing Properties of Area-Ordered and Size-Controlled Silicon Nanopillar

    Directory of Open Access Journals (Sweden)

    Wei Li

    2016-11-01

    Full Text Available Here, a silicon nanopillar array (Si-NPA was fabricated. It was studied as a room-temperature organic vapour sensor, and the ethanol and acetone gas sensing properties were detected with I-V curves. I-V curves show that these Si-NPA gas sensors are sensitive to ethanol and acetone organic vapours. The turn-on threshold voltage is about 0.5 V and the operating voltage is 3 V. With 1% ethanol gas vapour, the response time is 5 s, and the recovery time is 15 s. Furthermore, an evaluation of the gas sensor stability for Si-NPA was performed. The gas stability results are acceptable for practical detections. These excellent sensing characteristics can mainly be attributed to the change of the overall dielectric constant of Si-NPA caused by the physisorption of gas molecules on the pillars, and the filling of the gas vapour in the voids.

  1. Effect of water vapour absorption on hydroxyl temperatures measured from Svalbard

    Directory of Open Access Journals (Sweden)

    J. M. Chadney

    2017-03-01

    Full Text Available We model absorption by atmospheric water vapour of hydroxyl airglow emission using the HIgh-resolution TRANsmission molecular absorption database (HITRAN2012. Transmission coefficients are provided as a function of water vapour column density for the strongest OH Meinel emission lines in the (8–3, (5–1, (9–4, (8–4, and (6–2 vibrational bands. These coefficients are used to determine precise OH(8–3 rotational temperatures from spectra measured by the High Throughput Imaging Echelle Spectrograph (HiTIES, installed at the Kjell Henriksen Observatory (KHO, Svalbard. The method described in this paper also allows us to estimate atmospheric water vapour content using the HiTIES instrument.

  2. Inhalation dose assessment for Maralinga and Emu

    International Nuclear Information System (INIS)

    Johnston, P.N.; Lokan, K.H.; Williams, G.A.

    1990-01-01

    Dose assessments for the inhalation of artificial radionuclides are presented for all types of contaminated areas at Maralinga and Emu. These enable Committed Effective Dose Equivalent (CEDE), to be estimated by scaling at any area of interest where activity concentrations are known. In the case of Aborigines, these dose are estimated assuming respirable dust loadings of 1 mg/m 3 for adults and 1.5 mg/m 3 for children and infants. Details of the calculations are presented in the appendix. The model of the respiratory system used in this assessment is that described in Interantional Commission on Radiological Protection (ICRP) Publication 30 (ICRP, 1979a). With the exception of Kuli, which is contaminated with uranium, at all other sites it is only the inhalation of plutonium and americium that contributes significantly to the dose, and of these 239 Pu is the largest contributor. Therefore, considering the long half lives of the radionuclides concerned, it appears that the inhalation problems highlighted by this dose assessment will not diminish significantly within any reasonable period of time and hence management strategies must be developed to deal with such problems. 32 refs., 5 tabs., 1 fig

  3. Intrinsic stress of bismuth oxide thin films: effect of vapour chopping and air ageing

    International Nuclear Information System (INIS)

    Patil, R B; Puri, R K; Puri, V

    2008-01-01

    Bismuth oxide thin films of thickness 1000 A 0 have been prepared by thermal oxidation (in air) of vacuum evaporated bismuth thin films (on glass substrate) at different oxidation temperatures and duration. Both the vapour chopped and nonchopped bismuth oxide thin films showed polycrystalline and polymorphic structure. The monoclinic bismuth oxide was found to be predominant in both the cases. The effect of vapour chopping and air exposure for 40 days on the intrinsic stress of bismuth oxide thin films has been studied. The vapour chopped films showed low (3.92 - 4.80 x 10 9 N/m 2 ) intrinsic stress than those of nonchopped bismuth oxide thin films (5.77 - 6.74 x 10 9 N/m 2 ). Intrinsic stress was found to increase due to air ageing. The effect of air ageing on the vapour chopped films was found low. The vapour chopped films showed higher packing density. Higher the packing density, lower the film will age. The process of chopping vapour flow creates films with less inhomogenety i.e. a low concentration of flaws and non-planar defects which results in lower intrinsic stress

  4. Evaluation of blast wave damage from very large unconfined vapour cloud explosions

    International Nuclear Information System (INIS)

    Munday, G.

    1975-01-01

    A mathematical model is described for estimating the damage potential from unconfined vapour cloud explosions. An attempt has been made to cover the salient details of the explosive phenomenon including finite flame accelerations and finite vapour cloud sizes. The model has been evaluated against two industrial incidents and the results extrapolated to large-volume vapour clouds. The authors conclude, on the evidence of this model, that great care must be taken in the evaluation of the explosion hazard from the probable occurrence of very large unconfined explosions even at distances in excess of 1 km from the centre of initiation. (author)

  5. Desalination using spray tower and vapour compression refrigeration system

    International Nuclear Information System (INIS)

    Sathish Kumar, S.; Mani, A.

    2006-01-01

    A desalination system using a spray tower and Vapour Compression Refrigeration (VCR) system is proposed for obtaining fresh water from brackish water. In the spray tower, simultaneous heat and mass transfer take place between the brackish water and air, which results in the evaporation of the brackish water and humidification of the air. Fresh water is obtained from the humidified air by condensing the water vapour using a VCR system. Parametric studies were carried out to study the effect of various operational parameters on the fresh water production rate. (author)

  6. UTLS water vapour from SCIAMACHY limb measurementsV3.01 (2002-2012).

    Science.gov (United States)

    Weigel, K; Rozanov, A; Azam, F; Bramstedt, K; Damadeo, R; Eichmann, K-U; Gebhardt, C; Hurst, D; Kraemer, M; Lossow, S; Read, W; Spelten, N; Stiller, G P; Walker, K A; Weber, M; Bovensmann, H; Burrows, J P

    2016-01-01

    The SCanning Imaging Absorption spectroMeter for Atmospheric CHartographY (SCIAMACHY) aboard the Envisat satellite provided measurements from August 2002 until April 2012. SCIAMACHY measured the scattered or direct sunlight using different observation geometries. The limb viewing geometry allows the retrieval of water vapour at about 10-25 km height from the near-infrared spectral range (1353-1410 nm). These data cover the upper troposphere and lower stratosphere (UTLS), a region in the atmosphere which is of special interest for a variety of dynamical and chemical processes as well as for the radiative forcing. Here, the latest data version of water vapour (V3.01) from SCIAMACHY limb measurements is presented and validated by comparisons with data sets from other satellite and in situ measurements. Considering retrieval tests and the results of these comparisons, the V3.01 data are reliable from about 11 to 23 km and the best results are found in the middle of the profiles between about 14 and 20 km. Above 20 km in the extra tropics V3.01 is drier than all other data sets. Additionally, for altitudes above about 19 km, the vertical resolution of the retrieved profile is not sufficient to resolve signals with a short vertical structure like the tape recorder. Below 14 km, SCIAMACHY water vapour V3.01 is wetter than most collocated data sets, but the high variability of water vapour in the troposphere complicates the comparison. For 14-20 km height, the expected errors from the retrieval and simulations and the mean differences to collocated data sets are usually smaller than 10 % when the resolution of the SCIAMACHY data is taken into account. In general, the temporal changes agree well with collocated data sets except for the Northern Hemisphere extratropical stratosphere, where larger differences are observed. This indicates a possible drift in V3.01 most probably caused by the incomplete treatment of volcanic aerosols in the retrieval. In all other regions a

  7. Influence of ion size asymmetry on the properties of ionic liquid-vapour interfaces

    International Nuclear Information System (INIS)

    Bresme, Fernando; Gonzalez-Melchor, Minerva; Alejandre, Jose

    2005-01-01

    The influence of ion size asymmetry on the properties of ionic liquid-vapour interfaces is investigated using molecular dynamics simulations of the soft primitive model. Ion size asymmetry results in charge separation at the liquid-vapour interface and therefore in a local violation of the electroneutrality condition. For moderate size asymmetries the electrostatic potential at the interface can reach values of the order of 0.1 V. Size asymmetry plays a very important role in determining ion adsorption at the liquid-vapour interface of ionic mixtures. The interfacial adsorption of the bigger component results in an increase of the electrostatic potential, and a reduction of the interfacial surface tension. Our results show that ionic mixtures provide a very efficient way to tune the electrostatics and surface properties of ionic liquid-vapour interfaces

  8. Influence of ion size asymmetry on the properties of ionic liquid-vapour interfaces

    Energy Technology Data Exchange (ETDEWEB)

    Bresme, Fernando [Department of Chemistry, Imperial College London, London SW7 2AZ (United Kingdom); Gonzalez-Melchor, Minerva [Departamento de Fisica, Universidad Autonoma Metropolitana-Iztapalapa, Avenida San Rafael Atlixco 186, Colonia Vicentina, 09340 Mexico D.F. (Mexico); Alejandre, Jose [Departamento de QuImica, Universidad Autonoma Metropolitana-Iztapalapa, Avenida San Rafael Atlixco 186, Colonia Vicentina, 09340 Mexico D.F. (Mexico)

    2005-11-16

    The influence of ion size asymmetry on the properties of ionic liquid-vapour interfaces is investigated using molecular dynamics simulations of the soft primitive model. Ion size asymmetry results in charge separation at the liquid-vapour interface and therefore in a local violation of the electroneutrality condition. For moderate size asymmetries the electrostatic potential at the interface can reach values of the order of 0.1 V. Size asymmetry plays a very important role in determining ion adsorption at the liquid-vapour interface of ionic mixtures. The interfacial adsorption of the bigger component results in an increase of the electrostatic potential, and a reduction of the interfacial surface tension. Our results show that ionic mixtures provide a very efficient way to tune the electrostatics and surface properties of ionic liquid-vapour interfaces.

  9. Wavelength dependence four-wave mixing spectroscopy in a micrometric atomic vapour

    International Nuclear Information System (INIS)

    Yuan-Yuan, Li; Li, Li; Yan-Peng, Zhang; Si-Wen, Bi

    2010-01-01

    This paper presents a theoretical study of wavelength dependence four-wave-mixing (FWM) spectroscopy in a micrometric thin atomic vapour. It compares three cases termed as mismatched case I, matched case and mismatched case II for the probe wavelength less, equal and greater than the pump wavelength respectively. It finds that Dicke-narrowing can overcome width broadening induced by Doppler effects and polarisation interference of thermal atoms, and high resolution FWM spectra can be achieved both in matched and mismatched wavelength for many cases. It also finds that the magnitude of the FWM signal can be dramatically modified to be suppressed or to be enhanced in comparison with that of matched wavelength in mismatched case I or II. The width narrowing and the magnitude suppression or enhancement can be demonstrated by considering enhanced contribution of slow atoms induced by atom-wall collision and transient effect of atom-light interaction in a micrometric thin vapour. (general)

  10. A sensor of alcohol vapours based on thin polyaniline base film and quartz crystal microbalance.

    Science.gov (United States)

    Ayad, Mohamad M; El-Hefnawey, Gad; Torad, Nagy L

    2009-08-30

    Thin films of polyaniline base, emeraldine base (EB), coating on the quartz crystal microbalance (QCM) electrode were used as a sensitive layer for the detection of a number of primary aliphatic alcohols such as ethanol, methanol, 2-propanol and 1-propanol vapours. The frequency shifts (Deltaf) of the QCM were increased due to the vapour adsorption into the EB film. Deltaf were found to be linearly correlated with the concentrations of alcohols vapour in part per million (ppm). The sensitivity of the sensor was found to be governed by the chemical structure of the alcohol. The sensor shows a good reproducibility and reversibility. The diffusions of different alcohols vapour were studied and the diffusion coefficients (D) were calculated. It is concluded that the diffusion of the vapours into the EB film follows Fickian kinetics.

  11. The Use of VMD Data/Model to Test Different Thermodynamic Models for Vapour-Liquid Equilibrium

    DEFF Research Database (Denmark)

    Abildskov, Jens; Azquierdo-Gil, M.A.; Jonsson, Gunnar Eigil

    2004-01-01

    Vacuum membrane distillation (VMD) has been studied as a separation process to remove volatile organic compounds from aqueous streams. A vapour pressure difference across a microporous hydrophobic membrane is the driving force for the mass transport through the membrane pores (this transport take...... place in vapour phase). The vapour pressure difference is obtained in VMD processes by applying a vacuum on one side of the membrane. The membrane acts as a mere support for the liquid-vapour equilibrium. The evaporation of the liquid stream takes place on the feed side of the membrane...... values; membrane type: PTFE/PP/PVDF; feed flow rate; feed temperature. A comparison is made between different thermodynamic models for calculating the vapour-liquid equilibrium at the membrane/pore interface. (C) 2004 Elsevier B.V. All rights reserved....

  12. Cancer hazard from inhaled plutonium

    International Nuclear Information System (INIS)

    Gofman, J.W.

    1975-01-01

    The best estimate of the lung cancer potential in humans for inhaled insoluble compounds of plutonium (such as PuO 2 particles) has been grossly underestimated by such authoritative bodies as the International Commission on Radiological Protection and the British Medical Research Council. Calculations are presented of lung cancer induction by 239 Pu as insoluble particles and for deposited reactor-grade Pu. The reason for the gross underestimate of the carcinogenic effects of Pu by ICRP or the British Medical Research Council (BMRC) is their use of a totally unrealistic idealized model for the clearance of deposited Pu from the lungs and bronchi plus their non-recognition of the bronchi as the true site for most human lung cancers. The erroneous model used by such organizations also fails totally to take into account the effect of cigarette-smoking upon the physiological function of human lungs. Plutonium nuclides, such as 239 Pu, or other alpha particle-emitting nuclides, in an insoluble form represent an inhalation cancer hazard in a class some 100,000 times more potent than the potent chemical carcinogens, weight for weight. The already-existing lung cancer data for beagle dogs inhaling insoluble PuO 2 particles is clearly in order of magnitude agreement with calculations for humans

  13. Inhalation of antibiotics in cystic fibrosis

    NARCIS (Netherlands)

    Touw, D J; Brimicombe, R W; Hodson, M E; Heijerman, H G; Bakker, W

    Aerosol administration of antipseudomonal antibiotics is commonly used in cystic fibrosis. However, its contribution to the improvement of lung function, infection and quality of life is not well-established. All articles published from 1965 until the present time concerning the inhalation of

  14. Prediction of water vapour sorption isotherms and microstructure of hardened Portland cement pastes

    International Nuclear Information System (INIS)

    Burgh, James M. de; Foster, Stephen J.; Valipour, Hamid R.

    2016-01-01

    Water vapour sorption isotherms of cementitious materials reflect the multi-scale physical microstructure through its interaction with moisture. Our ability to understand and predict adsorption and desorption behaviour is essential in the application of modern performance-based approaches to durability analysis, along with many other areas of hygro-mechanical and hygro-chemo-mechanical behaviour. In this paper, a new physically based model for predicting water vapour sorption isotherms of arbitrary hardened Portland cement pastes is presented. Established thermodynamic principles, applied to a microstructure model that develops with hydration, provide a rational basis for predictions. Closed-form differentiable equations, along with a rational consideration of hysteresis and scanning phenomena, makes the model suitable for use in numerical moisture simulations. The microstructure model is reconciled with recently published 1 H NMR and mercury intrusion porosimetry results.

  15. Influence of inhaled Ca-DTPA on the long-term effects of inhaled Pu nitrate

    International Nuclear Information System (INIS)

    Ballou, J.E.; Dagle, G.E.; McDonald, K.E.; Buschbom, R.L.

    1975-01-01

    Inhaled Ca-DTPA administered to rats in 6 weekly, one-hour treatments of 3 mg/rat did not affect weight gain or life-span compared to Pu burdened animals (78 nCi ILB) or nontreated controls. In addition, the drug did not appear to promote the development of malignant lung tumors and bone tumors in Pu burdened rats although one rat exposed only to Ca-DTPA aerosols did develop a malignant lung tumor. This single lung tumor can not be considered significant although the normal incidence of this lesion is quite low. Inhaled Ca-DTPA therapy administered 20 days after Pu inhalation showed little effect in reducing the lung burden of plutonium. Skeletal deposition was decreased possibly because Ca-DTPA was administered during a time of active translocation of the inhaled Pu when Pu may have been available for chelation in the blood. Inhaled Ca-DTPA therapy did not appear to be beneficial in reducing the number of malignant lung tumors or bone tumors in plutonium burdened rats but on the other hand the chelate did not appear to promote these lesions. (U.S.)

  16. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  17. Continuous measurements of isotopic composition of water vapour on the East Antarctic Plateau

    Directory of Open Access Journals (Sweden)

    M. Casado

    2016-07-01

    Full Text Available Water stable isotopes in central Antarctic ice cores are critical to quantify past temperature changes. Accurate temperature reconstructions require one to understand the processes controlling surface snow isotopic composition. Isotopic fractionation processes occurring in the atmosphere and controlling snowfall isotopic composition are well understood theoretically and implemented in atmospheric models. However, post-deposition processes are poorly documented and understood. To quantitatively interpret the isotopic composition of water archived in ice cores, it is thus essential to study the continuum between surface water vapour, precipitation, surface snow and buried snow. Here, we target the isotopic composition of water vapour at Concordia Station, where the oldest EPICA Dome C ice cores have been retrieved. While snowfall and surface snow sampling is routinely performed, accurate measurements of surface water vapour are challenging in such cold and dry conditions. New developments in infrared spectroscopy enable now the measurement of isotopic composition in water vapour traces. Two infrared spectrometers have been deployed at Concordia, allowing continuous, in situ measurements for 1 month in December 2014–January 2015. Comparison of the results from infrared spectroscopy with laboratory measurements of discrete samples trapped using cryogenic sampling validates the relevance of the method to measure isotopic composition in dry conditions. We observe very large diurnal cycles in isotopic composition well correlated with temperature diurnal cycles. Identification of different behaviours of isotopic composition in the water vapour associated with turbulent or stratified regime indicates a strong impact of meteorological processes in local vapour/snow interaction. Even if the vapour isotopic composition seems to be, at least part of the time, at equilibrium with the local snow, the slope of δD against δ18O prevents us from identifying

  18. Data on thermal conductivity, water vapour permeability and water absorption of a cementitious mortar containing end-of-waste plastic aggregates

    OpenAIRE

    Di Maio, Luciano; Coppola, Bartolomeo; Courard, Luc; Michel, Frédéric; Incarnato, Loredana; Scarfato, Paola

    2018-01-01

    The data presented in this article are related to the research article entitled “Hygro-thermal and durability properties of a lightweight mortar made with foamed plastic waste aggregates ” (Coppola et al., 2018). This article focuses the attention on thermal conductivity, water vapour permeability and water absorption of a lightweight cementitious mortar containing foamed end-of-waste plastic aggregates, produced via foam extrusion process. Thermal conductivity, water vapour permeability ...

  19. the histological effects of formaldehyde vapour on the lungs

    African Journals Online (AJOL)

    Uwaifoh

    2012-12-31

    Dec 31, 2012 ... In the world day, the active chemical used for embalming is formaldehyde. ... formaldehyde causes nasopharyngeal cancer in humans,” (Collins et al., 1997; Gardner et ... pattern for inhalation of formaldehyde in rats presented cell ... temperature of about 25-28oC and photo-periodicity of 12h day/ 12h night.

  20. Modelling of vapour explosion in a stratified geometry

    International Nuclear Information System (INIS)

    Brayer, Claude

    1994-01-01

    A vapour explosion is the explosive vaporisation of a volatile liquid in contact with another hotter liquid. Such a violent vaporisation requires an intimate mixing and a fine fragmentation of both liquids. Based on a synthesis of published experimental results, the author of this research thesis reports the development of a new physical model which describes the explosion. In this model, the explosion propagation is due to the propagation of the pressure wave associated with this this explosion, all along the vapour film which initially separates both liquids. The author takes the presence of water in the liquid initially located over the film into account. This presence of vapour explains experimental propagation rates. Another consequence, when the pressure wave passes, is an acceleration of liquids at different rates below and above the film. The author considers that a mixture layer then forms from the point of disappearance of the film, between both liquids, and that fragmentation is due to the turbulence in this mixture layer. This fragmentation model is then introduced into an Euler thermodynamic, three-dimensional and multi-constituents code of calculation, MC3D, to study the influence of fragmentation on thermal exchanges between the various constituents on the volatile liquid vaporisation [fr

  1. Ethylene vinylacetate copolymer and nanographite composite as chemical vapour sensor

    International Nuclear Information System (INIS)

    Stepina, Santa; Sakale, Gita; Knite, Maris

    2013-01-01

    Polymer-nanostructured carbon composite as chemical vapour sensor is described, made by the dissolution method of a non-conductive polymer, ethylene vinylacetate copolymer, mixed with conductive nanographite particles (carbon black). Sensor exhibits relative electrical resistance change in chemical vapours, like ethanol and toluene. Since the sensor is relatively cheap, easy to fabricate, it can be used in air quality monitoring and at industries to control hazardous substance concentration in the air, for example, to protect workers from exposure to chemical spills

  2. Predicting Vapour Pressures of Organic Compounds from Their Chemical Structure for Classification According to the VOCDirective and Risk Assessment in General

    Directory of Open Access Journals (Sweden)

    Frands Nielsen

    2001-03-01

    Full Text Available The use of organic compounds in the European Union will in the future be regulated in accordance with the Council Directive 1999/13/EC of 11 March 1999 [1]. In this directive, any organic compound is considered to be a volatile organic compound (VOC if it has a vapour pressure of 10 Pa or more at 20oC, or has a corresponding volatility under the particular condition of use. Introduction of such a limit will sometimes create problems, because vapour pressures cannot be determined with an infinite accuracy. Published data on vapour pressures for a true VOC will sometimes be found to be below 10 Pa and vice versa. When the same limit was introduced in the USA, a considerable amount of time and money were spent in vain on comparing incommensurable data [2]. In this paper, a model is presented for prediction of the vapour pressures of VOCs at 20oC from their chemical (UNIFAC structure. The model is implemented in a computer program, named P_PREDICT, which has larger prediction power close to 10 Pa at 20oC than the other models tested. The main advantage of the model, however, is that no experimental data, which will introduce uncertainty in the predictions, is needed. Classification using P_PREDICT, which only predicts one value for a given UNIFAC structure, is proposed. Organic compounds, which can be described by the UNIFAC groups in the present version of P_PREDICT, therefore, can be classified unambiguously as either VOCs or non-VOCs. Most people, including the present authors, feel uneasy about prioritising precision above accuracy. Modelling vapour pressures, however, could save a lot of money and the errors introduced are not large enough to have any substantial adverse effects for neither human beings nor the environment. A method for calculating vapour pressures at other temperatures than 20oC is tested with a dubious result. This method is used for EU risk assessment of new and existing chemicals.

  3. Inhalation Injury: State of the Science 2016.

    Science.gov (United States)

    Foster, Kevin N; Holmes, James H

    This article summarizes research conducted over the last decade in the field of inhalation injury in thermally injured patients. This includes brief summaries of the findings of the 2006 State of the Science meeting with regard to inhalation injury, and of the subsequent 2007 Inhalation Injury Consensus Conference. The reviewed studies are categorized in to five general areas: diagnosis and grading; mechanical ventilation; systemic and inhalation therapy; mechanistic alterations; and outcomes.

  4. Vapour Pressure and Adiabatic Cooling from Champagne: Slow-Motion Visualization of Gas Thermodynamics

    Science.gov (United States)

    Vollmer, Michael; Mollmann, Klaus-Peter

    2012-01-01

    The recent introduction of inexpensive high-speed cameras offers a new experimental approach to many simple but fast-occurring events in physics. In this paper, the authors present two simple demonstration experiments recorded with high-speed cameras in the fields of gas dynamics and thermal physics. The experiments feature vapour pressure effects…

  5. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... Controlling Tools for Control Triggers Indoors In the Workplace Outdoors Management Asthma Action Plan Flu Shots Inhalers ... inhaler with a spacer Your browser does not support iframes Using a metered dose inhaler with a ...

  6. Operating experience of RAPSODIE and PHENIX relating to sodium aerosols and vapours

    Energy Technology Data Exchange (ETDEWEB)

    Delisle, J P; Reboul, M; Elie, X [DRNR/STRS - Centre de Cadarache, Saint-Paul-lez-Durance (France)

    1977-01-01

    The main difficulties resulting from sodium aerosols and vapours in the cover gas which have been encountered for 10 years in RAPSODIE and for 3 years in PHENIX are reviewed: condensation of sodium in annular spaces; plugging in primary gas pipes; plugging of filters and vapour traps. All those problems were easily overcome. (author)

  7. Alcohol vapours sensor based on thin polyaniline salt film and quartz crystal microbalance.

    Science.gov (United States)

    Ayad, Mohamad M; Torad, Nagy L

    2009-06-15

    A sensor based on the quartz crystal microbalance (QCM) technique was developed for detection of a number of primary aliphatic alcohols such as ethanol, methanol, 1-propanol, and 2-propanol vapours. Detection was based on a sensitive and a thin film of polyaniline, emeraldine salt (ES), coated the QCM electrode. The frequency shifts (Delta f) of the QCM were increased due to the vapour absorption into the ES film. The values of Delta f were found to be linearly correlated with the concentrations of alcohols vapour in mg L(-1). The changes in frequency are due to the hydrophilic character of the ES and the electrostatic interaction as well as the type of the alcohol. The sensor shows a good reproducibility and reversibility. The diffusion and diffusion coefficient (D) of different alcohols vapour were determined. It was found that the sensor follows Fickian kinetics.

  8. Multiscale network model for simulating liquid water and water vapour transfer properties of porous materials

    NARCIS (Netherlands)

    Carmeliet, J.; Descamps, F.; Houvenaghel, G.

    1999-01-01

    A multiscale network model is presented to model unsaturated moisture transfer in hygroscopic capillary-porous materials showing a broad pore-size distribution. Both capillary effects and water sorption phenomena, water vapour and liquid water transfer are considered. The multiscale approach is

  9. Radioactive gas inhalator

    International Nuclear Information System (INIS)

    LeMon, D.E.

    1975-01-01

    An ''inhalator'', or more particularly an apparatus for permitting a patient to inhale a radioactive gas in order to provide a diagnostic test of the patient's lung area, is described. The disclosed apparatus provides a simple, trouble-free mechanism for achieving this result; and, furthermore, provides an improved testing method. Moreover, the disclosed apparatus has the capability of gradually introducing the test condition in a manner that makes it easy for the patient to become acclimated to it. (U.S.)

  10. Remediation of sandy soils contaminated with hydrocarbons and halogenated hydrocarbons by soil vapour extraction.

    Science.gov (United States)

    Albergaria, José Tomás; Alvim-Ferraz, Maria da Conceição M; Delerue-Matos, Cristina

    2012-08-15

    This paper presents the study of the remediation of sandy soils containing six of the most common contaminants (benzene, toluene, ethylbenzene, xylene, trichloroethylene and perchloroethylene) using soil vapour extraction (SVE). The influence of soil water content on the process efficiency was evaluated considering the soil type and the contaminant. For artificially contaminated soils with negligible clay contents and natural organic matter it was concluded that: (i) all the remediation processes presented efficiencies above 92%; (ii) an increase of the soil water content led to a more time-consuming remediation; (iii) longer remediation periods were observed for contaminants with lower vapour pressures and lower water solubilities due to mass transfer limitations. Based on these results an easy and relatively fast procedure was developed for the prediction of the remediation times of real soils; 83% of the remediation times were predicted with relative deviations below 14%. Copyright © 2012 Elsevier Ltd. All rights reserved.

  11. Water vapour and methane coupling in the stratosphere observed using SCIAMACHY solar occultation measurements

    Directory of Open Access Journals (Sweden)

    S. Noël

    2018-04-01

    Full Text Available An improved stratospheric water vapour data set has been retrieved from SCIAMACHY/ENVISAT solar occultation measurements. It is similar to that successfully applied to methane and carbon dioxide. There is now a consistent set of data products for the three constituents covering the altitudes 17–45 km, the latitude range between about 50 and 70° N, and the period August 2002 to April 2012. The new water vapour concentration profiles agree with collocated results from ACE-FTS and MLS/Aura to within  ∼  5 %. A significant positive linear change in water vapour for the time 2003–2011 is observed at lower stratospheric altitudes with a value of about 0.015 ± 0.008 ppmv year−1 around 17 km. Between 30 and 37 km the changes become significantly negative (about −0.01 ± 0.008 ppmv year−1; all errors are 2σ values. The combined analysis of the SCIAMACHY methane and water vapour time series shows the expected anti-correlation between stratospheric methane and water vapour and a clear temporal variation related to the Quasi-Biennial Oscillation (QBO. Above about 20 km most of the additional water vapour is attributed to the oxidation of methane. In addition short-term fluctuations and longer-term variations on a timescale of 5–6 years are observed. The SCIAMACHY data confirm that at lower altitudes the amount of water vapour and methane are transported from the tropics to higher latitudes via the shallow branch of the Brewer–Dobson circulation.

  12. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... metered dose inhaler with a spacer [ PDF – 377 KB] Your browser does not support iframes Cómo usar ... inhalador de dosis fija con espaciador [PDF – 343 KB] Using a metered dose inhaler (inhaler in mouth) ...

  13. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.; Cannon, W.C.; Ragan, H.A.; Watson, C.R.; Stevens, D.L.; Cross, F.T.; Dionne, P.J.; Harrington, T.P.

    1978-01-01

    Beagle dogs given a single inhalation exposure to 239 Pu(NO 3 ) 4 are being observed for life-span dose-effect relationships. Lymphopenia occurred at the two highest dosage levels as early as 1 mo following exposure and was associated with neutropenia and reduction in numbers of circulatory monocytes by 4 mo postexposure. Radiation pneumonitis developed in one dog at the highest dosage level at 14 mo postexposure. More rapid translocation to skeleton and liver occurred following inhalation of 238 Pu(NO 3 ) 4 than after 239 Pu(NO 3 ) 4 inhalation

  14. Prediction of acute inhalation toxicity using in vitro lung surfactant inhibition.

    Science.gov (United States)

    Sørli, Jorid B; Huang, Yishi; Da Silva, Emilie; Hansen, Jitka S; Zuo, Yi Y; Frederiksen, Marie; Nørgaard, Asger W; Ebbehøj, Niels E; Larsen, Søren T; Hougaard, Karin S

    2018-01-01

    Private consumers and professionals may experience acute inhalation toxicity after inhaling aerosolized impregnation products. The distinction between toxic and non-toxic products is difficult to make for producers and product users alike, as there is no clearly described relationship between the chemical composition of the products and induction of toxicity. The currently accepted method for determination of acute inhalation toxicity is based on experiments on animals; it is time-consuming, expensive and causes stress for the animals. Impregnation products are present on the market in large numbers and amounts and exhibit great variety. Therefore, an alternative method to screen for acute inhalation toxicity is needed. The aim of our study was to determine if inhibition of lung surfactant by impregnation products in vitro could accurately predict toxicity in vivo in mice. We tested 21 impregnation products using the constant flow through set-up of the constrained drop surfactometer to determine if the products inhibited surfactant function or not. The same products were tested in a mouse inhalation bioassay to determine their toxicity in vivo. The sensitivity was 100%, i.e., the in vitro method predicted all the products that were toxic for mice to inhale. The specificity of the in vitro test was 63%, i.e., the in vitro method found three false positives in the 21 tested products. Six of the products had been involved in accidental human inhalation where they caused acute inhalation toxicity. All of these six products inhibited lung surfactant function in vitro and were toxic to mice.

  15. Vapour explosions (fuel-coolant interactions) resulting from the sub-surface injection of water into molten metals: preliminary results

    International Nuclear Information System (INIS)

    Asher, R.C.; Bullen, D.; Davies, D.

    1976-03-01

    Preliminary experiments are reported on the relationship between the injection mode of contact and the occurrence and magnitude of vapour explosions. Water was injected beneath the surface of molten metals, chiefly tin at 250 to 900 0 C. Vapour explosions occurred in many, but not all, cases. The results are compared with Dullforce's observations (Culham Report (CLM-P424) on the dropping mode of contact and it appears that rather different behaviour is found; in particular, the present results suggest that the Temperature Interaction Zone is different for the two modes of contact. (author)

  16. Teaching inhaler use in chronic obstructive pulmonary disease patients.

    Science.gov (United States)

    Lareau, Suzanne C; Hodder, Richard

    2012-02-01

    To review barriers to the successful use of inhalers in patients with chronic obstructive pulmonary disease (COPD), and the role of the nurse practitioner (NP) in facilitating optimum inhaler use. Review of the national and international scientific literature. Pharmacologic treatment of COPD patients comprises mainly inhaled medications. Incorrect use of inhalers is very common in these individuals. Some of the consequences of poor inhaler technique include reduced therapeutic dosing, medication adherence, and disease stability, which can lead to increased morbidity, decreased quality of life, and a high burden on the healthcare system. Knowledgeable evaluation and frequent reassessment of inhaler use coupled with education of patients, caregivers, and healthcare professionals can significantly improve the benefits COPD patients derive from inhaled therapy. Patient education is vital for correct use of inhalers and to ensure the effectiveness of inhaled medications. The NP has a critical role in assessing potential barriers to successful learning by the patient and improving inhaler technique and medication management. The NP can also facilitate success with inhaled medications by providing up-to-date inhaler education for other healthcare team members, who may then act as patient educators. ©2011 The Author(s) Journal compilation ©2011 American Academy of Nurse Practitioners.

  17. Acute Respiratory Distress Syndrome (ARDS After Nitric Acid Inhalation

    Directory of Open Access Journals (Sweden)

    Gülay Kır

    2014-12-01

    Full Text Available Lung injury resulting from inhalation of chemical products continues to be associated with high morbidity and mortality. Concentrated nitric acids are also extremely corrosive fuming chemical liquids. Fumes of nitric acid (HNO3 and various oxides of nitrogen such as nitric oxide (NO and nitrogen dioxide (NO2 may cause fatal illnesses such as severe pulmonary edema and acute respiratory distress syndrome (ARDS when inhaled. Intensive respiratory management including mechanical ventilation with positive end expiratory pressure (PEEP, inverse ratio ventilation, replacement of surfactant and extracorporeal membrane oxygenation (ECMO, steroids and n-acetylcysteine (NAC may improve survival. In this case report we present the diagnosis and successful treatment of a 57 years old male patient who developed ARDS following pulmonary edema due to nitric acid fumes inhalation.

  18. Evaluating inhaler use technique in COPD patients

    Directory of Open Access Journals (Sweden)

    Pothirat C

    2015-07-01

    Full Text Available Chaicharn Pothirat, Warawut Chaiwong, Nittaya Phetsuk, Sangnual Pisalthanapuna, Nonglak Chetsadaphan, Woranoot Choomuang Division of Pulmonary, Critical Care and Allergy, Department of Internal Medicine, Faculty of Medicine, Chiang Mai University, Chiang Mai, Thailand Background: Poor inhalation techniques are associated with decreased medication delivery and poor disease control in chronic obstructive pulmonary disease (COPD. The purpose of this study was to evaluate techniques for using inhaler devices in COPD patients.Methods: A prospective cross-sectional study was conducted to assess patient compliance with correct techniques for using inhaler devices across four regimens, ie, the pressurized metered-dose inhaler (pMDI, the pMDI with a spacer, the Accuhaler®, and the Handihaler®. The percentage of compliance with essential steps of correct device usage for each regimen was recorded without prior notification when COPD patients presented for a routine visit, and 1 month after receiving face-to-face training. We compared the percentage of compliance between the devices and risk factors related to incorrect techniques using logistic regression analysis. Percentage of patient compliance with correct techniques was compared between the two visits using the chi-square test. Statistical significance was set at P<0.05.Results: A total of 103 COPD patients (mean age 71.2±9.2 years, males 64.1%, low education level 82.5%, and percent predicted forced expiratory volume in 1 second 51.9±22.5 were evaluated. Seventy-seven patients (74.8% performed at least one step incorrectly. Patients using the Handihaler had the lowest compliance failure (42.5%, and the odds ratio for failure with the other devices compared with the Handihaler were 4.6 (95% confidence interval [CI] 1.8–11.8 for the pMDI, 3.1 (95% CI 1.2–8.2 for the pMDI with a spacer, and 2.4 (95% CI 1.1–5.2 for the Accuhaler. Low education level was the single most important factor related

  19. Estimation of chloroform inhalation dose by other routes based on the relationship of area under the blood concentration-time curve (AUC)-inhalation dose to chloroform distribution in the blood of rats.

    Science.gov (United States)

    Take, Makoto; Takeuchi, Tetsuya; Haresaku, Mitsuru; Matsumoto, Michiharu; Nagano, Kasuke; Yamamoto, Seigo; Takamura-Enya, Takeji; Fukushima, Shoji

    2014-01-01

    The present study investigated the time-course changes of concentration of chloroform (CHCl3) in the blood during and after exposure of male rats to CHCl3 by inhalation. Increasing the dose of CHCl3 in the inhalation exposed groups caused a commensurate increase in the concentration of CHCl3 in the blood and the area under the blood concentration-time curve (AUC). There was good correlation (r = 0.988) between the inhalation dose and the AUC/kg body weight. Based on the AUC/kg body weight-inhalation dose curve and the AUC/kg body weight after oral administration, inhalation equivalent doses of orally administered CHCl3 were calculated. Calculation of inhalation equivalent doses allows the body burden due to CHCl3 by inhalation exposure and oral exposure to be directly compared. This type of comparison facilitates risk assessment in humans exposed to CHCl3 by different routes. Our results indicate that when calculating inhalation equivalent doses of CHCl3, it is critical to include the AUC from the exposure period in addition to the AUC after the end of the exposure period. Thus, studies which measure the concentration of volatile organic compounds in the blood during the inhalation exposure period are crucial. The data reported here makes an important contribution to the physiologically based pharmacokinetic (PBPK) database of CHCl3 in rodents.

  20. Inhaled transuranics in rodents

    International Nuclear Information System (INIS)

    Sanders, C.L.

    1983-01-01

    This project examines the interactions of external and internal radiation from mixtures of radionuclides present within the nuclear fuel inventory. The objective of the project is to evaluate the effects of mixed radiation insults, using key radiation sources as indicative of overall processes that may occur following release of nuclear fuel into the air. Previously initiated studies of immunological effects of plutonium inhalation are also being completed as part of this project

  1. Inhalation device options for the management of chronic obstructive pulmonary disease.

    Science.gov (United States)

    DePietro, Michael; Gilbert, Ileen; Millette, Lauren A; Riebe, Michael

    2018-01-01

    Chronic obstructive pulmonary disease (COPD) is characterized by chronic respiratory symptoms and airflow limitation, resulting from abnormalities in the airway and/or damage to the alveoli. Primary care physicians manage the healthcare of a large proportion of patients with COPD. In addition to determining the most appropriate medication regimen, which usually includes inhaled bronchodilators with or without inhaled corticosteroids, physicians are charged with optimizing inhalation device selection to facilitate effective drug delivery and patient adherence. The large variety of inhalation devices currently available present numerous challenges for physicians that include: (1) gaining knowledge of and proficiency with operating different device classes; (2) identifying the most appropriate inhalation device for the patient; and (3) providing the necessary education and training for patients on device use. This review provides an overview of the inhalation device types currently available in the United States for delivery of COPD medications, including information on their successful operation and respective advantages and disadvantages, factors to consider in matching a device to an individual patient, the need for device training for patients and physicians, and guidance for improving treatment adherence. Finally, the review will discuss established and novel tools and technology that may aid physicians in improving education and promoting better adherence to therapy.

  2. Use of nitrite inhalants ("poppers") among American youth.

    Science.gov (United States)

    Wu, Li-Tzy; Schlenger, William E; Ringwalt, Chris L

    2005-07-01

    We examined the patterns and correlates of nitrite inhalant use among adolescents aged 12 to 17 years. Study data were drawn from the 2000 and 2001 National Household Surveys on Drug Abuse. Logistic regression was used to identify the characteristics associated with nitrite inhalant use. Among adolescents aged 12 to 17 years, 1.5% reported any lifetime use of nitrite inhalants. The prevalence of lifetime nitrite inhalant use increased to 12% and 14% among adolescents who were dependent on alcohol and any drug in the past year, respectively. Many nitrite inhalant users used at least three other types of inhalants (68%) and also met the criteria for alcohol (33%) and drug (35%) abuse or dependence. Increased odds of nitrite inhalant use were associated with residing in nonmetropolitan areas, recent utilization of mental health services, delinquent behaviors, past year alcohol and drug abuse and dependence, and multi-drug use. Adolescents who had used nitrite inhalants at least once in their lifetime tend to engage in delinquent activities and report co-occurring multiple drug abuse and mental health problems in the past year.

  3. Age dependent systemic exposure to inhaled salbutamol

    DEFF Research Database (Denmark)

    Bønnelykke, Klaus; Jespersen, Jakob Jessing; Bisgaard, Hans

    2007-01-01

    AIMS: To determine the effect of age on systemic exposure to inhaled salbutamol in children. METHODS: Fifty-eight asthmatic children, aged 3-16 years, inhaled 400 microg of salbutamol from a pressurized metered dose inhaler with spacer. The 20 min serum profile was analyzed. RESULTS: Prescribing...

  4. Utility of DMSP-SSM/I for integrated water vapour over the Indian seas

    Indian Academy of Sciences (India)

    R. Narasimhan (Krishtel eMaging Solutions)

    Recent algorithms for Special Sensor Microwave/Imager (DMSP-SSM/I) satellite data are used for estimating integrated water vapour over the Indian seas. Integrated water vapour obtained from these algorithms is compared with that derived from radiosonde observations at Minicoy and Port. Blair islands. Algorithm-3 of ...

  5. Effect of novel inhaler technique reminder labels on the retention of inhaler technique skills in asthma: a single-blind randomized controlled trial.

    Science.gov (United States)

    Basheti, Iman A; Obeidat, Nathir M; Reddel, Helen K

    2017-02-09

    Inhaler technique can be corrected with training, but skills drop off quickly without repeated training. The aim of our study was to explore the effect of novel inhaler technique labels on the retention of correct inhaler technique. In this single-blind randomized parallel-group active-controlled study, clinical pharmacists enrolled asthma patients using controller medication by Accuhaler [Diskus] or Turbuhaler. Inhaler technique was assessed using published checklists (score 0-9). Symptom control was assessed by asthma control test. Patients were randomized into active (ACCa; THa) and control (ACCc; THc) groups. All patients received a "Show-and-Tell" inhaler technique counseling service. Active patients also received inhaler labels highlighting their initial errors. Baseline data were available for 95 patients, 68% females, mean age 44.9 (SD 15.2) years. Mean inhaler scores were ACCa:5.3 ± 1.0; THa:4.7 ± 0.9, ACCc:5.5 ± 1.1; THc:4.2 ± 1.0. Asthma was poorly controlled (mean ACT scores ACCa:13.9 ± 4.3; THa:12.1 ± 3.9; ACCc:12.7 ± 3.3; THc:14.3 ± 3.7). After training, all patients had correct technique (score 9/9). After 3 months, there was significantly less decline in inhaler technique scores for active than control groups (mean difference: Accuhaler -1.04 (95% confidence interval -1.92, -0.16, P = 0.022); Turbuhaler -1.61 (-2.63, -0.59, P = 0.003). Symptom control improved significantly, with no significant difference between active and control patients, but active patients used less reliever medication (active 2.19 (SD 1.78) vs. control 3.42 (1.83) puffs/day, P = 0.002). After inhaler training, novel inhaler technique labels improve retention of correct inhaler technique skills with dry powder inhalers. Inhaler technique labels represent a simple, scalable intervention that has the potential to extend the benefit of inhaler training on asthma outcomes. REMINDER LABELS IMPROVE INHALER TECHNIQUE: Personalized

  6. GPS water vapour tomography: preliminary results from the ESCOMPTE field experiment

    Science.gov (United States)

    Champollion, C.; Masson, F.; Bouin, M.-N.; Walpersdorf, A.; Doerflinger, E.; Bock, O.; Van Baelen, J.

    2005-03-01

    Water vapour plays a major role in atmospheric processes but remains difficult to quantify due to its high variability in time and space and the sparse set of available measurements. The GPS has proved its capacity to measure the integrated water vapour at zenith with the same accuracy as other methods. Recent studies show that it is possible to quantify the integrated water vapour in the line of sight of the GPS satellite. These observations can be used to study the 3D heterogeneity of the troposphere using tomographic techniques. We develop three-dimensional tomographic software to model the three-dimensional distribution of the tropospheric water vapour from GPS data. First, the tomographic software is validated by simulations based on the realistic ESCOMPTE GPS network configuration. Without a priori information, the absolute value of water vapour is less resolved as opposed to relative horizontal variations. During the ESCOMPTE field experiment, a dense network of 17 dual frequency GPS receivers was operated for 2 weeks within a 20×20-km area around Marseille (southern France). The network extends from sea level to the top of the Etoile chain (˜700 m high). Optimal results have been obtained with time windows of 30-min intervals and input data evaluation every 15 min. The optimal grid for the ESCOMTE geometrical configuration has a horizontal step size of 0.05°×0.05° and 500 m vertical step size. Second, we have compared the results of real data inversions with independent observations. Three inversions have been compared to three successive radiosonde launches and shown to be consistent. A good resolution compared to the a priori information is obtained up to heights of 3000 m. A humidity spike at 4000-m altitude remains unresolved. The reason is probably that the signal is spread homogeneously over the whole network and that such a feature is not resolvable by tomographic techniques. The results of our pure GPS inversion show a correlation with

  7. Explosives vapour identification in ion mobility spectrometry using a tunable laser ionization source: a comparison with conventional 63Ni ionization

    International Nuclear Information System (INIS)

    Clark, A.; Deas, R.M.; Kosmidis, C.; Ledingham, K.W.D.; Marshall, A.; Singhal, R.P.

    1995-01-01

    Laser multiphoton ionization (MPI) is used to produce ions from explosive vapours at atmospheric pressure in air for analysis by ion mobility spectrometry (IMS). In the positive ion mode of detection, NO + ions, generated directly by multiphoton dissociation/ionization of the explosive compounds, show strong variation with laser wavelength. This provides a means of identifying the presence of nitro-containing compounds. Moreover, electrons formed in the MPI of gaseous components in the air carrier stream, primarily O 2 , are transferred via neutral molecular oxygen (O 2 ) to trace explosive vapour, forming negative ions which give rise to characteristic and identifiable ion mobility spectra. Further, negative ion mobility spectra of several explosive vapours are presented using conventional 63 Ni ionization and are compared qualitatively with the laser ionization approach. (author)

  8. Dew-point measurements at high water vapour pressure

    Science.gov (United States)

    Lomperski, S.; Dreier, J.

    1996-05-01

    A dew-point meter capable of measuring humidity at high vapour pressure and high temperature has been constructed and tested. Humidity measurements in pure steam were made over the temperature range 100 - 1500957-0233/7/5/003/img1C and a vapour pressure range of 1 - 4 bar. The dew-point meter performance was assessed by comparing measurements with a pressure transmitter and agreement between the two was within 0957-0233/7/5/003/img2% relative humidity. Humidity measurements in steam - air mixtures were also made and the dew-point meter readings were compared to those of a zirconia oxygen sensor. For these tests the dew-point meter readings were generally within 0957-0233/7/5/003/img2% relative humidity of the oxygen sensor measurements.

  9. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  10. E-cigarette versus nicotine inhaler: comparing the perceptions and experiences of inhaled nicotine devices.

    Science.gov (United States)

    Steinberg, Michael B; Zimmermann, Mia Hanos; Delnevo, Cristine D; Lewis, M Jane; Shukla, Parth; Coups, Elliot J; Foulds, Jonathan

    2014-11-01

    Novel nicotine delivery products, such as electronic cigarettes (e-cigarettes), have dramatically grown in popularity despite limited data on safety and benefit. In contrast, the similar U.S. Food and Drug Administration (FDA)-approved nicotine inhaler is rarely utilized by smokers. Understanding this paradox could be helpful to determine the potential for e-cigarettes as an alternative to tobacco smoking. To compare the e-cigarette with the nicotine inhaler in terms of perceived benefits, harms, appeal, and role in assisting with smoking cessation. A cross-over trial was conducted from 2012 to 2013 PARTICIPANTS/INTERVENTIONS: Forty-one current smokers age 18 and older used the e-cigarette and nicotine inhaler each for 3 days, in random order, with a washout period in between. Thirty-eight participants provided data on product use, perceptions, and experiences. The Modified Cigarette Evaluation Questionnaire (mCEQ) measured satisfaction, reward, and aversion. Subjects were also asked about each product's helpfulness, similarity to cigarettes, acceptability, image, and effectiveness in quitting smoking. Cigarette use was also recorded during the product-use periods. The e-cigarette had a higher total satisfaction score (13.9 vs. 6.8 [p e-cigarette received higher ratings for helpfulness, acceptability, and "coolness." More subjects would use the e-cigarette to make a quit attempt (76 %) than the inhaler (24 %) (p e-cigarette vs. 10 % (4/38) using the inhaler (p = 0.18). The e-cigarette was more acceptable, provided more satisfaction, and had higher perceived benefit than the inhaler during this trial. E-cigarettes have the potential to be important nicotine delivery products owing to their high acceptance and perceived benefit, but more data are needed to evaluate their actual efficacy and safety. Providers should be aware of these issues, as patients will increasingly inquire about them.

  11. Surface polish of PLA parts in FDM using dichloromethane vapour

    Directory of Open Access Journals (Sweden)

    Jin Yifan

    2017-01-01

    Full Text Available Fused deposition modelling has become one of the most diffused rapid prototyping techniques, which is widely used to fabricate prototypes. However, further application of this technology is severely limited by poor surface roughness. Thus it is necessary to adopt some operations to improve surface quality. Chemical finishing is typically employed to finish parts in fused deposition modelling (FDM. The purpose of this paper is to decrease the surface roughness for polylactic acid (PLA parts in FDM. The chemical reaction mechanism during the treating process is analysed. Then NaOH solution and dichloromethane vapour are used to treat FDM specimens respectively. A 3D laser microscope has been applied to assess the effects in terms of surface topography and roughness. The experimental results show that treatment using dichloromethane vapour performs much better than NaOH solution. Compared with the untreated group, surface roughness obtained through vapour treatment decreases by 88 per cent. This research has been conducted to provide a better method to treat PLA parts using chemical reagents.

  12. Imagine the Superiority of Dry Powder Inhalers from Carrier Engineering

    Directory of Open Access Journals (Sweden)

    Piyush Mehta

    2018-01-01

    Full Text Available Inhalation therapy has strong history of more than 4000 years and it is well recognized around the globe within every culture. In early days, inhalation therapy was designed for treatment of local disorders such as asthma and other pulmonary diseases. Almost all inhalation products composed a simple formulation of a carrier, usually α-lactose monohydrate orderly mixed with micronized therapeutic agent. Most of these formulations lacked satisfactory pulmonary deposition and dispersion. Thus, various alternative carrier’s molecules and powder processing techniques are increasingly investigated to achieve suitable aerodynamic performance. In view of this fact, more suitable and economic alternative carrier’s molecules with advanced formulation strategies are discussed in the present review. Furthermore, major advances, challenges, and the future perspective are discussed.

  13. Inhaled medication and inhalation devices for lung disease in patients with cystic fibrosis: A European consensus

    DEFF Research Database (Denmark)

    Heijerman, Harry; Westerman, Elsbeth; Conway, Steven

    2009-01-01

    , mucolytics/mucous mobilizers, anti-inflammatory drugs, bronchodilators and combinations of solutions. Additionally, we review the current knowledge on devices for inhalation therapy with regard to optimal particle sizes and characteristics of wet nebulisers, dry powder and metered dose inhalers. Finally, we...... review the current status of inhaled medication in CF, including the mechanisms of action of the various drugs, their modes of administration and indications, their effects on lung function, exacerbation rates, survival and quality of life, as well as side effects. Specifically we address antibiotics...

  14. Vapour-liquid equilibrium properties for two- and three-dimensional Lennard-Jones fluids from equations of state

    International Nuclear Information System (INIS)

    Mulero, A.; Cuadros, F; Faundez, C.A.

    1999-01-01

    Vapour-liquid equilibrium properties for both three- and two-dimensional Lennard-Jones fluids were obtained using simple cubic-in-density equations of state proposed by the authors. Results were compared with those obtained by other workers from computer simulations and also with results given by other more complex semi-theoretical or semi-empirical equations of state. In the three-dimensional case good agreement is found for all properties and all temperatures. In the two-dimensional case only the coexistence densities were compared, producing good agreement for low temperatures only. The present work is the first to give numerical data for the vapour-liquid equilibrium properties of Lennard-Jones fluids calculated from equations of state. Copyright (1999) CSIRO Australia

  15. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance; Etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif bilan biologique

    Energy Technology Data Exchange (ETDEWEB)

    Marble, G. [Commissariat a l' Energie Atomique, 92 - Fontenay-aux-Roses (France). Centre d' Etudes Nucleaires

    1968-07-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [French] L'etude experimentale de la contamination par inhalation d'aerosols d'iode radioactif effectuee chez le singe a fait l'objet de plusieurs publications. Les resultats concernant le bilan biologique de cette contamination sont presentes et discutes dans ce rapport. (auteur)

  16. Global distributions of water vapour isotopologues retrieved from IMG/ADEOS data

    Directory of Open Access Journals (Sweden)

    H. Herbin

    2007-07-01

    Full Text Available The isotopologic composition of water vapour in the atmosphere provides valuable information on many climate, chemical and dynamical processes. The accurate measurements of the water isotopologues by remote-sensing techniques remains a challenge, due to the large spatial and temporal variations. Simultaneous profile retrievals of the main water isotopologues (i.e. H216O, H218O and HDO and their ratios are presented here for the first time, along their retrieved global distributions. The results are obtained by exploiting the high resolution infrared spectra recorded by the Interferometric Monitor for Greenhouse gases (IMG instrument, which has operated in the nadir geometry onboard the ADEOS satellite between 1996 and 1997. The retrievals are performed on cloud-free radiances, measured during ten days of April 1997, considering two atmospheric windows (1205–1228 cm−1; 2004–2032 cm−1 and using a line-by-line radiative transfer model and an inversion procedure based on the Optimal Estimation Method (OEM. Characterizations in terms of vertical sensitivity and error budget are provided. We show that a relatively high vertical resolution is achieved for H216O (~4–5 km, and that the retrieved profiles are in fair agreement with local sonde measurements, at different latitudes. The retrieved global distributions of H216O, H218O, HDO and their ratios are presented and found to be consistent with previous experimental studies and models. The Ocean-Continent difference, the latitudinal and vertical dependence of the water vapour amount and the isotopologic depletion are notably well reproduced. Others trends, possibly related to small-scale variations in the vertical profiles are also discussed. Despite the difficulties encountered for computing accurately the isotopologic ratios, our results demonstrate the ability

  17. Inhalants

    Science.gov (United States)

    ... uses inhalants may be unable to learn new things or may have a hard time carrying on simple conversations. If the cerebral ... get drugs on the street, it is really hard to know what you get, Sometimes, ... put in, all sorts of things could happen. And other times, one might get ...

  18. Correlation of volatile carbonyl yields emitted by e-cigarettes with the temperature of the heating coil and the perceived sensorial quality of the generated vapours.

    Science.gov (United States)

    Geiss, Otmar; Bianchi, Ivana; Barrero-Moreno, Josefa

    2016-05-01

    E-liquids generally contain four main components: nicotine, flavours, water and carrier liquids. The carrier liquid dissolves flavours and nicotine and vaporises at a certain temperature on the atomizer of the e-cigarette. Propylene glycol and glycerol, the principal carriers used in e-liquids, undergo decomposition in contact with the atomizer heating-coil forming volatile carbonyls. Some of these, such as formaldehyde, acetaldehyde and acrolein, are of concern due to their adverse impact on human health when inhaled at sufficient concentrations. The aim of this study was to correlate the yield of volatile carbonyls emitted by e-cigarettes with the temperature of the heating coil. For this purpose, a popular commercial e-liquid was machine-vaped on a third generation e-cigarette which allowed the variation of the output wattage (5-25W) and therefore the heat generated on the atomizer heating-coil. The temperature of the heating-coil was determined by infrared thermography and the vapour generated at each temperature underwent subjective sensorial quality evaluation by an experienced vaper. A steep increase in the generated carbonyls was observed when applying a battery-output of at least 15W corresponding to 200-250°C on the heating coil. However, when considering concentrations in each inhaled puff, the short-term indoor air guideline value for formaldehyde was already exceeded at the lowest wattage of 5W, which is the wattage applied in most 2nd generation e-cigarettes. Concentrations of acetaldehyde in each puff were several times below the short-term irritation threshold value for humans. Acrolein was only detected from 20W upwards. The negative sensorial quality evaluation by the volunteering vaper of the vapour generated at 20W demonstrated the unlikelihood that such a wattage would be realistically set by a vaper. This study highlights the importance to develop standardised testing methods for the assessment of carbonyl-emissions and emissions of other

  19. Inhaled actinides: some safety issues and some research problems

    International Nuclear Information System (INIS)

    Bair, W.J.

    1978-01-01

    The following topics are discussed: limited research funds; risk coefficients for inhaled particles; the hot particle hypothesis; the Gofman-Martell contention; critical tissues for inhaled actinides inhalation hazards associated with future nuclear fuel cycles; and approach to be used by the inhalation panel

  20. Solvation-based vapour pressure model for (solvent + salt) systems in conjunction with the Antoine equation

    International Nuclear Information System (INIS)

    Senol, Aynur

    2013-01-01

    Highlights: • Vapour pressures of (solvent + salt) systems have been estimated through a solvation-based model. • Two structural forms of the generalized solvation model using the Antoine equation have been performed. • A simplified concentration-dependent vapour pressure model has been also processed. • The model reliability analysis has been performed in terms of a log-ratio objective function. • The reliability of the models has been interpreted in terms of the statistical design factors. -- Abstract: This study deals with modelling the vapour pressure of a (solvent + salt) system on the basis of the principles of LSER. The solvation model framework clarifies the simultaneous impact of several physical variables such as the vapour pressure of a pure solvent estimated by the Antoine equation, the solubility and solvatochromic parameters of the solvent and the physical properties of the ionic salt. It has been analyzed independently the performance of two structural forms of the generalized model, i.e., a relation depending on an integration of the properties of the solvent and the ionic salt and a relation on a reduced property-basis. A simplified concentration-dependent vapour pressure model has been also explored and implemented on the relevant systems. The vapour pressure data of sixteen (solvent + salt) systems have been processed to analyze statistically the reliability of existing models in terms of a log–ratio objective function. The proposed vapour pressure models match relatively well the observed performance, yielding the overall design factors of 1.066 and 1.073 for the solvation-based models with the integrated and reduced properties, and 1.008 for the concentration-based model, respectively

  1. Modelling of vapour explosion in stratified geometrie

    International Nuclear Information System (INIS)

    Picchi, St.

    1999-01-01

    When a hot liquid comes into contact with a colder volatile liquid, one can obtain in some conditions an explosive vaporization, told vapour explosion, whose consequences can be important on neighbouring structures. This explosion needs the intimate mixing and the fine fragmentation between the two liquids. In a stratified vapour explosion, these two liquids are initially superposed and separated by a vapor film. A triggering of the explosion can induce a propagation of this along the film. A study of experimental results and existent models has allowed to retain the following main points: - the explosion propagation is due to a pressure wave propagating through the medium; - the mixing is due to the development of Kelvin-Helmholtz instabilities induced by the shear velocity between the two liquids behind the pressure wave. The presence of the vapour in the volatile liquid explains experimental propagation velocity and the velocity difference between the two fluids at the pressure wave crossing. A first model has been proposed by Brayer in 1994 in order to describe the fragmentation and the mixing of the two fluids. Results of the author do not show explosion propagation. We have therefore built a new mixing-fragmentation model based on the atomization phenomenon that develops itself during the pressure wave crossing. We have also taken into account the transient aspect of the heat transfer between fuel drops and the volatile liquid, and elaborated a model of transient heat transfer. These two models have been introduced in a multi-components, thermal, hydraulic code, MC3D. Results of calculation show a qualitative and quantitative agreement with experimental results and confirm basic options of the model. (author)

  2. Internal dose from tritium at Wolsung nuclear power plant

    International Nuclear Information System (INIS)

    Hee Geun Kim; Jeong Yull Dho; Myung Jae Song

    1995-01-01

    Tritium is produced in large quantities at heavy water nuclear power reactors via the neutron activation reaction 2 H(n,γ) 3 H. At Wolsung nuclear power plant which has a CANDU reactor, the tritium concentrations in coolant and in moderator systems are 1.5 Ci/Kg-D 2 O and 35 Ci/kg-D 2 O, respectively, after 12 years of operation. The airborne tritium concentration in main access area is normally less than 5 MPCa except short-term peaks. The average tritium concentrations in main access controlled areas are normally less than 100 MPCa. Tritium is mainly present in the air of workplace of CANDU reactors as a tritiated water vapour. Airborne tritiated water vapour enters the workers body via inhalation and absorption through skin and can result in a significant dose. The occupational doses from tritium at Wolsung NPP have been maintained below 1 man-Sv per year so far. The tritium contribution to the total plant man-Sv changes between 30 percent and 50 percent. For the mitigation of tritium inhalation, various protective equipment are being used at Wolsung NPP. The respirator system was devised at Wolsung NPP in order to remove tritiated water vapours from the inhaled air. A respirator is connected to a small plastic bottle filled with ice cubes. The system devised shows a good tritium removal efficiency. The air pressure drop through the ice cubes is minimal. The operation cost of the system is also very cheap. Further mitigation of tritium inhalation is heavily dependant on the source term reduction. One of the ultimate solutions is to introduce a tritium removal facility. (author). 7 figs., 3 tabs

  3. Effect of Organic Vapour on Porous Alumina Based Moisture Sensor in Dry Gases

    Directory of Open Access Journals (Sweden)

    Saakshi DHANEKAR

    2009-08-01

    Full Text Available A capacitive porous alumina based trace moisture sensor in the range of 50 to 500 ppm (V was fabricated by low cost sol-gel technique. The cross-sensitivities due to the presence of organic vapours like ethanol, methanol, acetone and benzene were studied. The change in response and recovery time with ppm for moisture sensing was also calculated. The experimental results conclude that moisture sensor is responsive to the polar organic vapours but has almost negligible response to the nonpolar molecules like benzene. Response of the sensor to the organic vapours as compared to the moisture sensitivity is very less. The effect of ambient temperature was found to be negligible.

  4. Atomic-scale Studies of Uranium Oxidation and Corrosion by Water Vapour.

    Science.gov (United States)

    Martin, T L; Coe, C; Bagot, P A J; Morrall, P; Smith, G D W; Scott, T; Moody, M P

    2016-07-12

    Understanding the corrosion of uranium is important for its safe, long-term storage. Uranium metal corrodes rapidly in air, but the exact mechanism remains subject to debate. Atom Probe Tomography was used to investigate the surface microstructure of metallic depleted uranium specimens following polishing and exposure to moist air. A complex, corrugated metal-oxide interface was observed, with approximately 60 at.% oxygen content within the oxide. Interestingly, a very thin (~5 nm) interfacial layer of uranium hydride was observed at the oxide-metal interface. Exposure to deuterated water vapour produced an equivalent deuteride signal at the metal-oxide interface, confirming the hydride as originating via the water vapour oxidation mechanism. Hydroxide ions were detected uniformly throughout the oxide, yet showed reduced prominence at the metal interface. These results support a proposed mechanism for the oxidation of uranium in water vapour environments where the transport of hydroxyl species and the formation of hydride are key to understanding the observed behaviour.

  5. Atomic-scale Studies of Uranium Oxidation and Corrosion by Water Vapour

    Science.gov (United States)

    Martin, T. L.; Coe, C.; Bagot, P. A. J.; Morrall, P.; Smith, G. D. W.; Scott, T.; Moody, M. P.

    2016-07-01

    Understanding the corrosion of uranium is important for its safe, long-term storage. Uranium metal corrodes rapidly in air, but the exact mechanism remains subject to debate. Atom Probe Tomography was used to investigate the surface microstructure of metallic depleted uranium specimens following polishing and exposure to moist air. A complex, corrugated metal-oxide interface was observed, with approximately 60 at.% oxygen content within the oxide. Interestingly, a very thin (~5 nm) interfacial layer of uranium hydride was observed at the oxide-metal interface. Exposure to deuterated water vapour produced an equivalent deuteride signal at the metal-oxide interface, confirming the hydride as originating via the water vapour oxidation mechanism. Hydroxide ions were detected uniformly throughout the oxide, yet showed reduced prominence at the metal interface. These results support a proposed mechanism for the oxidation of uranium in water vapour environments where the transport of hydroxyl species and the formation of hydride are key to understanding the observed behaviour.

  6. Hair analysis as a useful procedure for detection of vapour exposure to chemical warfare agents: simulation of sulphur mustard with methyl salicylate.

    Science.gov (United States)

    Spiandore, Marie; Piram, Anne; Lacoste, Alexandre; Josse, Denis; Doumenq, Pierre

    2014-06-01

    Chemical warfare agents (CWA) are highly toxic compounds which have been produced to kill or hurt people during conflicts or terrorist attacks. Despite the fact that their use is strictly prohibited according to international convention, populations' exposure still recently occurred. Development of markers of exposure to CWA is necessary to distinguish exposed victims from unexposed ones. We present the first study of hair usage as passive sampler to assess contamination by chemicals in vapour form. This work presents more particularly the hair adsorption capacity for methyl salicylate used as a surrogate of the vesicant sulphur mustard. Chemical vapours toxicity through the respiratory route has historically been defined through Haber's law's concentration-time (Ct) product, and vapour exposure of hair to methyl salicylate was conducted with various times or doses of exposure in the range of incapacitating and lethal Ct products corresponding to sulphur mustard. Following exposure, extraction of methyl salicylate from hair was conducted by simple soaking in dichloromethane. Methyl salicylate could be detected on hair for vapour concentration corresponding to about one fifth of the sulphur mustard concentration that would kill 50% of exposed individuals (LCt50). The amount of methyl salicylate recovered from hair increased with time or dose of exposure. It showed a good correlation with the concentration-time product, suggesting that hair could be used like a passive sampler to assess vapour exposure to chemical compounds. It introduces great perspectives concerning the use of hair as a marker of exposure to CWA. Copyright © 2014 John Wiley & Sons, Ltd.

  7. Ease-of-use preference for the ELLIPTA® dry powder inhaler over a commonly used single-dose capsule dry powder inhaler by inhalation device-naïve Japanese volunteers aged 40 years or older

    Directory of Open Access Journals (Sweden)

    Komase Y

    2014-12-01

    Full Text Available Yuko Komase,1 Akimoto Asako,2 Akihiro Kobayashi,3 Raj Sharma4 1Department of Respiratory Internal Medicine, St Marianna University School of Medicine, Yokohama City Seibu Hospital, Yokohama, Kanagawa, Japan; 2MA Respiratory Department, Development and Medical Affairs Unit, GlaxoSmithKline KK, Tokyo, Japan; 3Biomedical Data Sciences Department, GlaxoSmithKline KK, Tokyo, Japan; 4Global Respiratory Franchise Medical Department, GSK, Stockley Park, UK Background: In patients receiving inhaled medication, dissatisfaction with and difficulty in using the inhaler can affect treatment adherence. The incidence of handling errors is typically higher in the elderly than in younger people. The aim of the study was to assess inhaler preference for and handling errors with the ELLIPTA® dry powder inhaler (DPI, (GSK, compared with the established BREEZHALER™, a single-dose capsule DPI (Novartis, in inhalation device-naïve Japanese volunteers aged ≥40 years. Methods: In this open-label, nondrug interventional, crossover DPI preference study comparing the ELLIPTA DPI and BREEZHALER, 150 subjects were randomized to handle the ELLIPTA or BREEZHALER DPIs until the point of inhalation, without receiving verbal or demonstrative instruction (first attempt. Subjects then crossed over to the other inhaler. Preference was assessed using a self-completed questionnaire. Inhaler handling was assessed by a trained assessor using a checklist. Subjects did not inhale any medication in the study, so efficacy and safety were not measured. Results: The ELLIPTA DPI was preferred to the BREEZHALER by 89% of subjects (odds ratio [OR] 70.14, 95% confidence interval [CI] 33.69–146.01; P-value not applicable for this inhaler for ease of use, by 63% of subjects (OR 2.98, CI 1.87–4.77; P<0.0001 for ease of determining the number of doses remaining in the inhaler, by 91% for number of steps required, and by 93% for time needed for handling the inhaler. The BREEZHALER was

  8. Conference report: 1st Medicon Valley Inhalation Symposium.

    Science.gov (United States)

    Lastow, Orest

    2013-02-01

    The 1st Medicon Valley Inhalation Symposium was arranged by the Medicon Valley Inhalation Consortium. It was held at the Medicon Village site, which is the former AstraZeneca site in Lund, Sweden. It was a 1-day symposium focused on inhaled drug delivery and inhalation product development. A total of 90 delegates listened to 15 speakers. The program was organized to follow the value chain of an inhalation product development. The benefits and future opportunities of inhaled drug delivery were discussed together with some new disease areas that can be targeted with inhalation. The pros and cons of the two main formulation types; dry powder and liquid formulations, were discussed by a panel. The different requirements of the drug molecules from a pharmacology, chemical and physical perspective were explained. The modeling of the physics inside an inhaler was demonstrated and the potential strategic benefits of device design were highlighted together with the many challenges of formulation manufacturing. Lung deposition mechanisms and the difficulties of the generic bioequivalence concept were discussed. Using an anatomically correct impactor inlet is a valuable tool in lung deposition predictions and the planning of clinical trials. The management of the biological material generated in clinical studies is key to successful studies.

  9. Workplace Inhalant Abuse in Adult Female: Brief Report

    Directory of Open Access Journals (Sweden)

    Rohit Verma

    2011-01-01

    Full Text Available Inhalant abuse is the purposeful inhalation of intoxicating gases and vapors for the purpose of achieving an altered mental state. With its propensity for being yet an under-recognized form of substance use, being gateway to hard substances, cross-cultural penetration crossing socioeconomic boundaries, and causing significant morbidity and mortality in early ages, the prevention of inhalant misuse is a highly pertinent issue. This clinical report identifies a newer perspective in the emergence of inhalant abuse initiation. We report a case of an adult female with late onset of inhalant dependence developing at workplace and recommend for greater awareness, prevention, and management of this expanding substance abuse problem.

  10. Thermal diffusion of water vapour in porous materials: fact or fiction?

    DEFF Research Database (Denmark)

    Janssen, Hans

    2011-01-01

    diffusion. Thermal diffusion opponents, on the other hand, assert that these thermal transports are negligibly small. This paper resolves that contradiction. A critical analysis of the investigations supporting the occurrence of thermal diffusion reveals that all are flawed. A correct reinterpretation...... its negligible magnitude. It can in conclusion be stated that thermal diffusion is of no importance for building science applications, leaving vapour pressure as the sole significant transport potential for the diffusion of water vapour in porous materials. (C) 2010 Elsevier Ltd. All rights reserved....

  11. Sudden death due to inhalant abuse in youth: Case report

    Directory of Open Access Journals (Sweden)

    Ramazan Akcan

    2010-06-01

    Full Text Available Intentional inhalation or abuse of volatile substances is a common public health problem all over the world. As these substances generate euphoria frequency of use among adolescents and young adults is increasing steadily. In cases using inhalants to achieve a euphoric state -without knowing possible consequences- sudden death may occurdue to acute cardio-pulmonary dysfunction.Here we present a case of sudden death of a nineteen-year-old female due to inhalation of volatile from butane containing lighter gas tube, with the findings of autopsy and death scene investigation.In the context of this case; it was aimed to draw attention to the risk of sudden death and steady increase of frequencyof volatile substance abuse among adolescents and young adults due to various psycho-social factors.

  12. Organ burdens and elimination rates of inhaled thorium and plutonium

    International Nuclear Information System (INIS)

    Unnikrishnan, K.; Murthy, K.B.S.; Sunta, C.M.

    1986-01-01

    For the purpose of interpreting observations from internal monitoring programmes, organ burdens and excretion rates resulting from inhalation of long-lived isotopes of plutonium and thorium have been calculated, on the basis of the ICRP model. Two types of inhalation, instantaneous (acute) and at a steady rate (chronic) are considered. The expected buildups of the burden in lungs, lymph nodes, bone, liver and other tissues, as well as the excretion rates, have been calculated for aerosol classes W and Y, and particle sizes of AMAD 1 μm and 6 μm. Further, in view of their use in selecting the periodicity of routine monitoring, theoretical results are also presented for the case of a total inhalation of 1 ALI in one year, instantaneously or at a constant rate. (author)

  13. Synthesis and evaluation of inhaled [11C]butane and intravenously injected [11C]acetone as potential radiotracers for studying inhalant abuse

    International Nuclear Information System (INIS)

    Gerasimov, Madina R.; Ferrieri, Richard A.; Pareto, Deborah; Logan, Jean; Alexoff, David; Ding Yushin

    2005-01-01

    The phenomenon of inhalant abuse is a growing problem in the US and many countries around the world. Yet, relatively little is known about the pharmacokinetic properties of inhalants that underlie their abuse potential. While the synthesis of 11 C-labeled toluene, acetone and butane has been proposed in the literature, none of these compounds has been developed as radiotracers for PET studies. In the present report we extend our previous studies with [ 11 C]toluene to include [ 11 C]acetone and [ 11 C]butane with the goal of comparing the pharmacokinetic profiles of these three volatile abused substances. Both [ 11 C]toluene and [ 11 C]acetone were administered intravenously and [ 11 C]butane was administered via inhalation to anesthesized baboons. Rapid and efficient uptake of radiolabeled toluene and acetone into the brain was followed by fast clearance in the case of toluene and slower kinetics in the case of acetone. [ 11 C]Butane was detected in the blood and brain following inhalation, but the levels of radioactivity in both tissues dropped to half of the maximal values over the period of less than a minute. To our knowledge, this is the first reported study of the in vivo brain pharmacokinetics of labeled acetone and butane in nonhuman primates. These data provide insight into the pharmacokinetic features possibly associated with the abuse liability of toluene, acetone and butane

  14. The Advantages of Low-Flow Inhalational Anesthesia

    Directory of Open Access Journals (Sweden)

    P. Torok

    2005-01-01

    Full Text Available The paper deals with the economical and ecological use of inhalation anesthetics in low-flow anesthesia (LFA, 1—0.5 l/ min and high-flow anesthesia (HFA, more than 2—6 l/min. Four hundred and ninety six inhalational anesthesias lasting at least 80 minutes were analyzed in each group under consideration. The concentration of inhalation anesthetics was measures in the atmosphere of an operative theatre if inhalational anesthesia lasted more than 4 hours. There is evidence for the economical and ecological benefits in the use of LFA in terms of the availability of appropriate anesthesiological equipment, monitoring, and a highly skilled anesthesiologist.

  15. Inhalation treatment of primary lung cancer using liposomal curcumin dry powder inhalers

    Directory of Open Access Journals (Sweden)

    Tongtong Zhang

    2018-05-01

    Full Text Available Lung cancer is the leading cause of cancer-related deaths. Traditional chemotherapy causes serious toxicity due to the wide bodily distribution of these drugs. Curcumin is a potential anticancer agent but its low water solubility, poor bioavailability and rapid metabolism significantly limits clinical applications. Here we developed a liposomal curcumin dry powder inhaler (LCD for inhalation treatment of primary lung cancer. LCDs were obtained from curcumin liposomes after freeze-drying. The LCDs had a mass mean aerodynamic diameter of 5.81 μm and a fine particle fraction of 46.71%, suitable for pulmonary delivery. The uptake of curcumin liposomes by human lung cancer A549 cells was markedly greater and faster than that of free curcumin. The high cytotoxicity on A549 cells and the low cytotoxicity of curcumin liposomes on normal human bronchial BEAS-2B epithelial cells yielded a high selection index partly due to increased cell apoptosis. Curcumin powders, LCDs and gemcitabine were directly sprayed into the lungs of rats with lung cancer through the trachea. LCDs showed higher anticancer effects than the other two medications with regard to pathology and the expression of many cancer-related markers including VEGF, malondialdehyde, TNF-α, caspase-3 and BCL-2. LCDs are a promising medication for inhalation treatment of lung cancer with high therapeutic efficiency. Key words: Curcumin, Dry powder inhaler, Liposome, Primary lung cancer, Pulmonary delivery

  16. Near real-time estimation of water vapour in the troposphere using ground GNSS and the meteorological data

    Directory of Open Access Journals (Sweden)

    J. Bosy

    2012-09-01

    Full Text Available The near real-time (NRT high resolution water vapour distribution models can be constructed based on GNSS observations delivered from Ground Base Augmentation Systems (GBAS and ground meteorological data. Since 2008 in the territory of Poland, a GBAS system called ASG-EUPOS (Active Geodetic Network has been operating. This paper addresses the problems concerning construction of the NRT model of water vapour distribution in the troposphere near Poland. The first section presents all available GNSS and ground meteorological stations in the area of Poland and neighbouring countries. In this section, data feeding scheme is discussed, together with timeline and time resolution. The high consistency between measured and interpolated temperature value is shown, whereas some discrepancy in the pressure is observed. In the second section, the NRT GNSS data processing strategy of ASG-EUPOS network is discussed. Preliminary results show fine alignment of the obtained Zenith Troposphere Delays (ZTDs with reference data from European Permanent Network (EPN processing center. The validation of NRT troposphere products against daily solution shows 15 mm standard deviation of obtained ZTD differences. The last section presents the first results of 2-D water vapour distribution above the GNSS network and application of the tomographic model to 3-D distribution of water vapour in the atmosphere. The GNSS tomography model, working on the simulated data from numerical forecast model, shows high consistency with the reference data (by means of standard deviation 4 mm km−1 or 4 ppm, however, noise analysis shows high solution sensitivity to errors in observations. The discrepancy for real data preliminary solution (measured as a mean standard deviation between reference NWP data and tomography data was on the level of 9 mm km−1 (or 9 ppm in terms of wet refractivity.

  17. Distribution of tritium in water vapour and precipitation around Wolsung nuclear power plant.

    Science.gov (United States)

    Chae, Jung-Seok; Lee, Sang-Kuk; Kim, Yongjae; Lee, Jung-Min; Cho, Heung-Joon; Cho, Yong-Woo; Yun, Ju-Yong

    2011-07-01

    The distribution of tritium in water vapour and precipitation with discharge of tritiated water vapour and meteorological factors was studied around the Wolsung nuclear power plant (NPP) site during the period 2004-2008. The tritium concentrations in atmospheric water vapour and precipitation had a temporal variation with relatively high values in the early summer. Spatial distribution of tritium concentrations was affected by various factors such as distance from the NPP site, wind direction, tritium discharge into the atmosphere and atmospheric dispersion factor. The annual mean concentrations of atmospheric HTO and precipitation were correlated with the amount of gaseous tritium released from the Wolsung NPP. The tritium concentrations in precipitation decrease exponentially with an increase of the distance from the Wolsung NPP site.

  18. Vectors for Inhaled Gene Therapy in Lung Cancer. Application for Nano Oncology and Safety of Bio Nanotechnology

    Science.gov (United States)

    Zarogouldis, Paul; Karamanos, Nikos K.; Porpodis, Konstantinos; Domvri, Kalliopi; Huang, Haidong; Hohenforst-Schimdt, Wolfgang; Goldberg, Eugene P.; Zarogoulidis, Konstantinos

    2012-01-01

    Novel aerosol therapeutic modalities have been investigated for lung cancer. Inhaled gene therapy has presented safety and effectiveness previously in cystic fibrosis. However, safety concerns have been raised regarding the safety of non-viral vectors for inhaled gene therapy in lung cancer, and therefore small steps have been made towards this multifunctional treatment modality. During the last decade, numerous new nanocomplexes have been created and investigated as a safe gene delivery nano-vehicle. These formulations are multifunctional; they can be used as either local therapy or carrier for an effective inhaled gene therapy for lung cancer. Herein, we present current and future perspectives of nanocomplexes for inhaled gene therapy treatment in lung cancer. PMID:23109824

  19. Electrical Behaviour of Chitosan-Silver Nanocomposite in Presence of Water Vapour

    Directory of Open Access Journals (Sweden)

    Bal Yadav

    2017-04-01

    Full Text Available This paper presents the synthesis, characterization of the nanocomposite of silver and chitosan polymer composite reinforced by cellulose fibre and its electrical behaviour in presence of water vapour. The coated paper has been characterized by XRD, IR, SEM and EDX techniques. The size of silver nanoparticles is found to be around 9 nm and deposited uniformly. Chitosan, as well as cellulose, contain a hydrogen attached to electronegative nitrogen and oxygen. This gives a favourable environment for the formation of hydrogen bonds. IR peaks of the composite infer the intermolecular hydrogen bonding between the two constituents. The SEM pictures show that the coating of the fibres with nanoparticles is quite uniform. EDX analysis shows that the coated filter paper has sufficient amount of silver along with carbon and oxygen. The coated paper shows good sensitivity towards humidity. It gives excellent linearity in response with a concentration of water vapour after heat treatment of composite at 130 °C. The sensitivity of the sensor is 0.8 MΩ per unit of relative humidity. Sensing properties originate from protonic conductivity from adsorbed water molecule.

  20. Diffusion and flow of water vapours in chromatographic Alumina gel

    International Nuclear Information System (INIS)

    Khan, M.; Shah, H. U.

    2005-01-01

    The kinetics of sorption of water vapours in chromatographic alumina gel was studied. Water vapours are adsorbed on the gel at temperature (15 degree C) at different constant relative pressure from 0.1-0.93 p/p. Rate constant, Effective diffusivities, Knudsen diffusivities and bulk diffusivities were determined through Fick type equation. Total pore volume is 0.498 cc g-1 and specific surface area comes to be 465 m2 g-1 as obtained by Gurvitsch rule and Kieselve's quantities respectively. An average pore radius (hydraulic) is 1.1x10/sub -7/ cm. The study of these quantities provide a strong basis for evaluating surface properties. (author)

  1. Solvent Vapour Detection with Cholesteric Liquid Crystals—Optical and Mass-Sensitive Evaluation of the Sensor Mechanism

    Directory of Open Access Journals (Sweden)

    Adnan Mujahid

    2010-05-01

    Full Text Available Cholesteric liquid crystals (CLCs are used as sensitive coatings for the detection of organic solvent vapours for both polar and non-polar substances. The incorporation of different analyte vapours in the CLC layers disturbs the pitch length which changes the optical properties, i.e., shifting the absorption band. The engulfing of CLCs around non-polar solvent vapours such as tetrahedrofuran (THF, chloroform and tetrachloroethylene is favoured in comparison to polar ones, i.e., methanol and ethanol. Increasing solvent vapour concentrations shift the absorbance maximumto smaller wavelengths, e.g., as observed for THF. Additionally, CLCs have been coated on acoustic devices such as the quartz crystal microbalance (QCM to measure the frequency shift of analyte samples at similar concentration levels. The mass effect for tetrachloroethylene was about six times higher than chloroform. Thus, optical response can be correlated with intercalation in accordance to mass detection. The mechanical stability was gained by combining CLCs with imprinted polymers. Therefore, pre-concentration of solvent vapours was performed leading to an additional selectivity.

  2. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea

    International Nuclear Information System (INIS)

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-01-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3–0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01–0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1–10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. - Highlights: • Size-dependent aerosol number was measured along the path of subway user. • Particles less than 0.4 μm were inhaled in outdoor but less so as deeper underground. • Coarse particles were inhaled significantly as users moved deeper underground. - We estimated the inhaled aerosol number concentration depending on particle size along the path of subway users.

  3. Inhaler devices - from theory to practice

    DEFF Research Database (Denmark)

    Sanchis, Joaquin; Corrigan, Chris; Levy, Mark L

    2013-01-01

    This brief overview of the factors determining lung deposition of aerosols provides background information required by health care providers when instructing patients to use their prescribed inhalers. We discuss differences in the optimal inhalation manoeuvres for each type of aerosol generator a...

  4. Rapid-Onset Diffuse Skeletal Fluorosis from Inhalant Abuse: A Case Report.

    Science.gov (United States)

    Cohen, Eric; Hsu, Raymond Y; Evangelista, Peter; Aaron, Roy; Rubin, Lee E

    A thirty-year-old man presented with severely debilitating left hip pain and stiffness. Radiographs demonstrated diffuse osteosclerosis and heterotopic bone formation with near ankylosis of the left hip. The patient underwent successful joint-preserving surgery to restore hip range of motion. After disclosing a history of inhalant abuse, which was confirmed by elevated serum fluoride levels, he was diagnosed with diffuse skeletal fluorosis. To the best of our knowledge, we present the first reported case of diffuse skeletal fluorosis caused by inhalant abuse of 1,1-difluoroethane. Skeletal fluorosis is uncommon in the United States but is important to consider in the differential diagnosis when a patient presents with otherwise unexplained joint pain and osteosclerosis.

  5. Inhalation Toxicology Research Institute. Annual report, October 1, 1978-September 30, 1979

    International Nuclear Information System (INIS)

    Henderson, R.F.; Diel, J.H.; Martinez, B.S.

    1979-12-01

    Research information is given by the annual report from the Inhalation Toxicology Research Institute with abstracts for each of the 109 papers. Major sections of interest are nuclear energy toxicology, solar energy toxicology, diesel technology toxicology, coal technology toxicology, and conservation technology toxicology. Also included are seven appendices covering publications of technical reports and publications in open literature, abstracts publications in the open literature, seminars presented by visiting scientists and presentations before scientific meetings, organization of the Inhalation Toxicology Research Institute, and the status of experiments using beagle dogs

  6. Collisional effects on metastable atom population in vapour generated by electron beam heating

    International Nuclear Information System (INIS)

    Dikshit, B; Majumder, A; Bhatia, M S; Mago, V K

    2008-01-01

    The metastable atom population distribution in a free expanding uranium vapour generated by electron beam (e-beam) heating is expected to depart from its original value near the source due to atom-atom collisions and interaction with electrons of the e-beam generated plasma co-expanding with the vapour. To investigate the dynamics of the electron-atom and atom-atom interactions at different e-beam powers (or source temperatures), probing of the atomic population in ground (0 cm -1 ) and 620 cm -1 metastable states of uranium was carried out by the absorption technique using a hollow cathode discharge lamp. The excitation temperature of vapour at a distance ∼30 cm from the source was calculated on the basis of the measured ratio of populations in 620 to 0 cm -1 states and it was found to be much lower than both the source temperature and estimated translational temperature of the vapour that is cooled by adiabatic free expansion. This indicated relaxation of the metastable atoms by collisions with low energy plasma electrons was so significant that it brings the excitation temperature below the translational temperature of the vapour. So, with increase in e-beam power and hence atom density, frequent atom-atom collisions are expected to establish equilibrium between the excitation and translational temperatures, resulting in an increase in the excitation temperature (i.e. heating of vapour). This has been confirmed by analysing the experimentally observed growth pattern of the curve for excitation temperature with e-beam power. From the observed excitation temperature at low e-beam power when atom-atom collisions can be neglected, the total de-excitation cross section for relaxation of the 620 cm -1 state by interaction with low energy electrons was estimated and was found to be ∼10 -14 cm 2 . Finally using this value of cross section, the extent of excitational cooling and heating by electron-atom and atom-atom collisions are described at higher e-beam powers

  7. Inhalant-Abuse Myocarditis Diagnosed by Cardiac Magnetic Resonance.

    Science.gov (United States)

    Dinsfriend, William; Rao, Krishnasree; Matulevicius, Susan

    2016-06-01

    Multiple reports of toxic myocarditis from inhalant abuse have been reported. We now report the case of a 23-year-old man found to have toxic myocarditis from inhalation of a hydrocarbon. The diagnosis was made by means of cardiac magnetic resonance imaging with delayed enhancement. The use of cardiac magnetic resonance to diagnose myocarditis has become increasingly common in clinical medicine, although there is not a universally accepted criterion for diagnosis. We appear to be the first to document a case of toxic myocarditis diagnosed by cardiac magnetic resonance. In patients with a history of drug abuse who present with clinical findings that suggest myocarditis or pericarditis, cardiac magnetic resonance can be considered to support the diagnosis.

  8. Measurement of copper vapour laser-induced deformation of ...

    Indian Academy of Sciences (India)

    2014-02-14

    Feb 14, 2014 ... Laser & Plasma Technology Division, Beam Technology Development Group,. Bhabha Atomic ... of dielectric-coated mirror, caused by an incident repetitive pulsed laser beam with high average power. Minimum ... the optical surface deformation, caused by irradiation by a copper vapour laser (CVL) beam.

  9. Evaluation of Inhaled Versus Deposited Dose Using the Exponential Dose-Response Model for Inhalational Anthrax in Nonhuman Primate, Rabbit, and Guinea Pig.

    Science.gov (United States)

    Gutting, Bradford W; Rukhin, Andrey; Mackie, Ryan S; Marchette, David; Thran, Brandolyn

    2015-05-01

    The application of the exponential model is extended by the inclusion of new nonhuman primate (NHP), rabbit, and guinea pig dose-lethality data for inhalation anthrax. Because deposition is a critical step in the initiation of inhalation anthrax, inhaled doses may not provide the most accurate cross-species comparison. For this reason, species-specific deposition factors were derived to translate inhaled dose to deposited dose. Four NHP, three rabbit, and two guinea pig data sets were utilized. Results from species-specific pooling analysis suggested all four NHP data sets could be pooled into a single NHP data set, which was also true for the rabbit and guinea pig data sets. The three species-specific pooled data sets could not be combined into a single generic mammalian data set. For inhaled dose, NHPs were the most sensitive (relative lowest LD50) species and rabbits the least. Improved inhaled LD50 s proposed for use in risk assessment are 50,600, 102,600, and 70,800 inhaled spores for NHP, rabbit, and guinea pig, respectively. Lung deposition factors were estimated for each species using published deposition data from Bacillus spore exposures, particle deposition studies, and computer modeling. Deposition was estimated at 22%, 9%, and 30% of the inhaled dose for NHP, rabbit, and guinea pig, respectively. When the inhaled dose was adjusted to reflect deposited dose, the rabbit animal model appears the most sensitive with the guinea pig the least sensitive species. © 2014 Society for Risk Analysis.

  10. Development of modular thermostatic vapour-cooled current leads for cryogenic service

    International Nuclear Information System (INIS)

    Blessing, H.; Lebrun, P.

    1983-01-01

    Cryogenic current leads cooled by helium vapour have been developed, built and tested. Their construction, based on standard electrolytic copper braids crimped at the ends, is such as to provide flexible cold terminations and make possible a modular design. The warm terminations combine electrical insulation, leak-tightness and integrated thermostatic valves controlling lead temperature and avoiding thermal run-away or ice build-up. After giving a detailed description of their construction, this report presents results of performance and reliability tests made on prototype units. (orig.)

  11. Water vapour and wind measurements by a two micron space lidar

    Science.gov (United States)

    Ghibaudo, J.-B.; Labandibar, J.-Y.

    2018-04-01

    AEROSPATIALE presents the main results of the feasibility study under ESA contract on a coherent 2μm lidar instrument capable of measuring water vapour and wind velocity in the planetary boundary layer. The selected instrument configuration and the associated performance are provided, and the main critical subsystems identified (laser configuration, coherent receiver chain architecture, frequency locking and offsetting architecture. The second phase of this study is dedicated to breadboard the most critical elements of such an instrument in order to technologically consolidate its feasibility.

  12. Measurement of water vapour transport through a porous non-hygroscopic material in a temperature gradient

    DEFF Research Database (Denmark)

    Hansen, Thor; Padfield, Tim; Hansen, Kurt Kielsgaard

    2014-01-01

    This was an experiment to identify the driving potential for water vapour diffusion through porous materials in a temperature gradient. The specimen of mineral fibre insulation was placed between a space with controlled temperature and relative humidity and a space with a controlled, higher...... temperature, and a measured but not controlled relative humidity (RH). This assembly was allowed to reach equilibrium with no vapour movement between the spaces, as tested by a constant RH on each side and by zero flux of water vapour measured in the cold side chamber. The RH and temperature values were...

  13. Long-term effects of aluminium dust inhalation.

    Science.gov (United States)

    Peters, Susan; Reid, Alison; Fritschi, Lin; de Klerk, Nicholas; Musk, A W Bill

    2013-12-01

    During the 1950s and 1960s, aluminium dust inhalation was used as a potential prophylaxis against silicosis in underground miners, including in Australia. We investigated the association between aluminium dust inhalation and cardiovascular, cerebrovascular and Alzheimer's diseases in a cohort of Australian male underground gold miners. We additionally looked at pneumoconiosis mortality to estimate the effect of the aluminium therapy. SMRs and 95% CI were calculated to compare mortality of the cohort members with that of the Western Australian male population (1961-2009). Internal comparisons on duration of aluminium dust inhalation were examined using Cox regression. Aluminium dust inhalation was reported for 647 out of 1894 underground gold miners. During 42 780 person-years of follow-up, 1577 deaths were observed. An indication of increased mortality of Alzheimer's disease among miners ever exposed to aluminium dust was found (SMR=1.38), although it was not statistically significant (95% CI 0.69 to 2.75). Rates for cardiovascular and cerebrovascular death were above population levels, but were similar for subjects with or without a history of aluminium dust inhalation. HRs suggested an increasing risk of cardiovascular disease with duration of aluminium dust inhalation (HR=1.02, 95% CI 1.00 to 1.04, per year of exposure). No difference in the association between duration of work underground and pneumoconiosis was observed between the groups with or without aluminium dust exposure. No protective effect against silicosis was observed from aluminium dust inhalation. Conversely, exposure to aluminium dust may possibly increase the risk of cardiovascular disease and dementia of the Alzheimer's type.

  14. Assessing inhalation injury in the emergency room

    Directory of Open Access Journals (Sweden)

    Tanizaki S

    2015-07-01

    Full Text Available Shinsuke Tanizaki Department of Emergency Medicine, Fukui Prefectural Hospital, Fukui, Japan Abstract: Respiratory tract injuries caused by inhalation of smoke or chemical products are related to significant morbidity and mortality. While many strategies have been built up to manage cutaneous burn injuries, few logical diagnostic strategies for patients with inhalation injuries exist and almost all treatment is supportive. The goals of initial management are to ensure that the airway allows adequate oxygenation and ventilation and to avoid ventilator-induced lung injury and substances that may complicate subsequent care. Intubation should be considered if any of the following signs exist: respiratory distress, stridor, hypoventilation, use of accessory respiratory muscles, blistering or edema of the oropharynx, or deep burns to the face or neck. Any patients suspected to have inhalation injuries should receive a high concentration of supplemental oxygen to quickly reverse hypoxia and to displace carbon monoxide from protein binding sites. Management of carbon monoxide and cyanide exposure in smoke inhalation patients remains controversial. Absolute indications for hyperbaric oxygen therapy do not exist because there is a low correlation between carboxyhemoglobin levels and the severity of the clinical state. A cyanide antidote should be administered when cyanide poisoning is clinically suspected. Although an ideal approach for respiratory support of patients with inhalation injuries do not exist, it is important that they are supported using techniques that do not further exacerbate respiratory failure. A well-organized strategy for patients with inhalation injury is critical to reduce morbidity and mortality. Keywords: inhalation injury, burn, carbon monoxide poisoning, cyanide poisoning

  15. Inhaled plutonium oxide in dogs

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This project is concerned with long-term experiments to determine the life-span dose-effect relationships of inhaled 239 PuO 2 and 238 PuO 2 in beagles. The data will be used to estimate the health effects of inhaled transuranics. The tissue distribution of plutonium, radiation effects in the lung and hematologic changes in plutonium-exposed beagles with lung tumors were evaluated

  16. 49 CFR 172.555 - POISON INHALATION HAZARD placard.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false POISON INHALATION HAZARD placard. 172.555 Section... REQUIREMENTS, AND SECURITY PLANS Placarding § 172.555 POISON INHALATION HAZARD placard. (a) Except for size and color, the POISON INHALATION HAZARD placard must be as follows: ER22JY97.025 (b) In addition to...

  17. Lung dose and lung cancer risk by inhalation of radon daughters

    International Nuclear Information System (INIS)

    Jacobi, W.

    1983-01-01

    The inhalation of short-lived radon daughters constitutes the most important occupational radiation exposure in mines, particularly in uranium mines. Among some groups of miners exposed in the past to relatively high radon levels, an excess lung cancer incidence has been observed. In addition to this occupational hazard, the observed radon levels in domestic houses indicate that the inhalation of short-lived radon daughters seems to be the most important component of the radiation exposure of the population from natural sources. For the quantification and judgment of the radiological impact by inhalation of radon daughters in mines as well as in houses, it is necessary to estimate the relationships between the inhaled activity or potential alpha (α) energy of these radionuclides, the dose to target tissues in the lung, and the possible associated lung cancer (LC) risk. It is the purpose of this paper to give a condensed review of our present knowledge in this field and to indicate the main gaps and uncertainties where future research seems necessary

  18. Determination of splenic blood flow by inhalation of radioactive rare gases

    Energy Technology Data Exchange (ETDEWEB)

    Huchzermeyer, H; Schmitz-Feuerhake, I; Reblin, T [Medizinische Hochschule Hannover (Germany, F.R.). Abt. fuer Nuklearmedizin und Spezielle Biophysik; Medizinische Hochschule Hannover (Germany, F.R.). Abt. fuer Gastroenterologie)

    1977-10-01

    We have evaluated the /sup 133/Xenon inhalation method for the determination of splenic blood flow. In twenty-two healthy persons the blood flow was on average 109 +- 4 ml/100 g x min, which is equivalent to a total blood flow of about 170 ml/min. In patients with chronic fatty liver hepatitis specific blood flow was reduced (81 +- 10 ml/100 g x min) as it was in patients with cirrhotic liver without splenomegaly (75 +- 2 ml/100 g x min.). With increasing weight of the spleen, the total blood flow rises, although specific blood flow is low. Our results obtained by the /sup 133/Xenon inhalation method are similar to results obtained by others using intraarterial injection of tracer gas. The advantages of the inhalation method as a non-traumatic method are: 1) the stress for the patient is very small; 2) blood flow measurements can be repeated within short periods of time. We consider for the present the /sup 133/Xenon inhalation method to be the method of choice for the determination of the splenic blood flow.

  19. Dry Powder Inhalers: A Focus on Advancements in Novel Drug Delivery Systems

    Directory of Open Access Journals (Sweden)

    Piyush Mehta

    2016-01-01

    Full Text Available Administration of drug molecules by inhalation route for treatment of respiratory diseases has the ability to deliver drugs, hormones, nucleic acids, steroids, proteins, and peptides, particularly to the site of action, improving the efficacy of the treatment and consequently lessening adverse effects of the treatment. Numerous inhalation delivery systems have been developed and studied to treat respiratory diseases such as asthma, COPD, and other pulmonary infections. The progress of disciplines such as biomaterials science, nanotechnology, particle engineering, molecular biology, and cell biology permits further improvement of the treatment capability. The present review analyzes modern therapeutic approaches of inhaled drugs with special emphasis on novel drug delivery system for treatment of various respiratory diseases.

  20. 49 CFR 172.429 - POISON INHALATION HAZARD label.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 2 2010-10-01 2010-10-01 false POISON INHALATION HAZARD label. 172.429 Section... REQUIREMENTS, AND SECURITY PLANS Labeling § 172.429 POISON INHALATION HAZARD label. (a) Except for size and color, the POISON INHALATION HAZARD label must be as follows: ER22JY97.023 (b) In addition to complying...

  1. Study of vapour pressure of lithium nitrate solutions in ethanol

    Energy Technology Data Exchange (ETDEWEB)

    Verevkin, Sergey [Abteilung Physikalische Chemie, Institut fuer Chemie, Universitaet Rostock, Hermannstrasse, 14, D-18055 Rostock (Germany); Safarov, Javid [Heat and Refrigeration Techniques, Azerbaijan Technical University, H. Javid Avn. 25, AZ1073 Baku (Azerbaijan)]. E-mail: javids@azdata.net; Bich, Eckard [Abteilung Physikalische Chemie, Institut fuer Chemie, Universitaet Rostock, Hermannstrasse, 14, D-18055 Rostock (Germany); Hassel, Egon [Lehrstuhl fuer Technische Thermodynamik, Fakultaet Maschinenbau und Schiffstechnik, Universitaet Rostock, Albert-Einstein-Str. 2, D-18059 Rostock (Germany); Heintz, Andreas [Abteilung Physikalische Chemie, Institut fuer Chemie, Universitaet Rostock, Hermannstrasse, 14, D-18055 Rostock (Germany)

    2006-05-15

    Vapour pressure p of (LiNO{sub 3} + C{sub 2}H{sub 5}OH) solutions at T = (298.15 to 323.15) K were measured, osmotic, activity coefficients ({phi}, {gamma}) and activity of solvent a {sub s} have been evaluated. The experiments were carried out in the molality range m = (0.19125 to 2.21552) mol . kg{sup -1}. The Antoine equation was used for the empirical description of the experimental vapour pressure results and the (Pitzer + Mayorga) model with inclusion of Archer's ionic strength dependence of the third virial coefficient for the calculated osmotic coefficients were used. The parameters of the Archer for the extended Pitzer model was used for the evaluation of activity coefficients.

  2. Vapour pressure and enthalpy of vaporization of aliphatic poly-amines

    International Nuclear Information System (INIS)

    Efimova, Anastasia A.; Emel'yanenko, Vladimir N.; Verevkin, Sergey P.; Chernyak, Yury

    2010-01-01

    Molar enthalpies of vaporization of aliphatic poly-amines: 1,4-dimethylpiperazine [106-58-1], 1-(2-aminoethyl)-piperazine, [140-31-8], 1-(2-aminoethyl)-4-methyl-piperazine [934-98-5], and triethylenetetramine [112-24-3] were obtained from the temperature dependence of the vapour pressure measured by the transpiration method. A large number of the primary experimental results on temperature dependences of vapour pressures of the parent compounds have been collected from the literature and have been treated uniformly in order to derive vaporization enthalpies of poly-amines at the reference temperature 298.15 K. An internal consistency check was performed on enthalpy of vaporization values for poly-amines studied in this work.

  3. A miniature discriminating monitor for tritiated water vapour

    Energy Technology Data Exchange (ETDEWEB)

    Edwards, R.A.H.; Ravazzani, A.; Pacenti, P. [European Commission, JRC, Institute for Advanced Material, Ispra, Vatican City State, Holy See (Italy); Campi, F. [Nuclear Engineering Dept., Polytechnic of Milan (Italy)

    1998-07-01

    In detecting tritium in air (or other gas) for worker safety, it is important to discriminate between tritiated water vapour and elemental tritium, because the first is much more easily absorbed in the lungs. We haveinvented (patent pending) an innovative discriminating monitor which works better than existing designs, and is much smaller. The air (or other sample gas) passes over a large surface area of solid scintillator, which is surface-treated to make it hygroscopic. Tritiated water vapour in the air exchanges continuously, rapidly and reversibly with the water in the thin hygroscopic layer; which is of the order of 1 micron thick. The beta-emissions from tritium in the hygroscopic layer hit the solid scintillator, causing flashes of light that are detected by a photomultiplier. The new discriminating monitor for tritiated species in air offers superior performance to existing discriminating monitors, and is much smaller. It is planned to develop a portable version which could serve as a personal tritium monitor. (authors)

  4. Improvement of a thermoelectric and vapour compression hybrid refrigerator

    International Nuclear Information System (INIS)

    Astrain, D.; Martínez, A.; Rodríguez, A.

    2012-01-01

    This paper presents the improvement in the performance of a domestic hybrid refrigerator that combines vapour compression technology for the cooler and freezer compartments, and thermoelectric technology for a new compartment. The heat emitted by the Peltier modules is discharged into the freezer compartment, forming a cascade refrigeration system. This configuration leads to a significant improvement in the coefficient of operation. Thus, the electric power consumption of the modules and the refrigerator decreases by 95% and 20% respectively, with respect to those attained with a cascade refrigeration system connected with the cooler compartment. The optimization process is based on a computational model that simulates the behaviour of the whole refrigerator. Two prototypes have been built and tested. Experimental results indicate that the temperature of the new compartment is easily set up at any value between 0 and −4 °C, the oscillation of this temperature is always lower than 0.4 °C, and the electric power consumption is low enough to include this hybrid refrigerator into energy efficiency class A, according European rules and regulations. - Highlights: ► Optimization of a vapour compression and thermoelectric hybrid refrigerator. ► Two prototypes built and tested. Computational model for the whole refrigerator. ► Electric power consumption of the modules and the refrigerator 95% and 20% lower. ► New compartment refrigerated with thermoelectric technology. ► Inner temperature adjustable from 0 to −4 °C. Oscillations lower than ±0.2 °C.

  5. Inhaled antibiotics for lower airway infections.

    Science.gov (United States)

    Quon, Bradley S; Goss, Christopher H; Ramsey, Bonnie W

    2014-03-01

    Inhaled antibiotics have been used to treat chronic airway infections since the 1940s. The earliest experience with inhaled antibiotics involved aerosolizing antibiotics designed for parenteral administration. These formulations caused significant bronchial irritation due to added preservatives and nonphysiologic chemical composition. A major therapeutic advance took place in 1997, when tobramycin designed for inhalation was approved by the U.S. Food and Drug Administration (FDA) for use in patients with cystic fibrosis (CF) with chronic Pseudomonas aeruginosa infection. Attracted by the clinical benefits observed in CF and the availability of dry powder antibiotic formulations, there has been a growing interest in the use of inhaled antibiotics in other lower respiratory tract infections, such as non-CF bronchiectasis, ventilator-associated pneumonia, chronic obstructive pulmonary disease, mycobacterial disease, and in the post-lung transplant setting over the past decade. Antibiotics currently marketed for inhalation include nebulized and dry powder forms of tobramycin and colistin and nebulized aztreonam. Although both the U.S. Food and Drug Administration and European Medicines Agency have approved their use in CF, they have not been approved in other disease areas due to lack of supportive clinical trial evidence. Injectable formulations of gentamicin, tobramycin, amikacin, ceftazidime, and amphotericin are currently nebulized "off-label" to manage non-CF bronchiectasis, drug-resistant nontuberculous mycobacterial infections, ventilator-associated pneumonia, and post-transplant airway infections. Future inhaled antibiotic trials must focus on disease areas outside of CF with sample sizes large enough to evaluate clinically important endpoints such as exacerbations. Extrapolating from CF, the impact of eradicating organisms such as P. aeruginosa in non-CF bronchiectasis should also be evaluated.

  6. A novel hybrid tobacco product that delivers a tobacco flavour note with vapour aerosol (Part 1): Product operation and preliminary aerosol chemistry assessment.

    Science.gov (United States)

    Poynton, Simon; Sutton, Joseph; Goodall, Sharon; Margham, Jennifer; Forster, Mark; Scott, Ken; Liu, Chuan; McAdam, Kevin; Murphy, James; Proctor, Christopher

    2017-08-01

    Vapour products have demonstrated potential to be a lower-risk alternative to cigarettes. The present study describes a novel hybrid tobacco product that combines a warm aerosol stream generated by an electronic vaporisation mechanism with tobacco top flavour from cut tobacco. During operation, the aerosol stream released from the vapour cartomiser is passed through a bed of blended cut tobacco by the puffing flow, elevating the tobacco temperature and eluting volatile tobacco flavour components. A preliminary but comprehensive analysis of the aerosol composition of the hybrid tobacco product found that emissions were dominated by the control vapour formulation. In non-targeted chemical screening, no detectable difference in GC scans was observed between the hybrid tobacco product and the control vapour product. However, a sensorially elevated tobacco flavour was confirmed by a consumer sensory panel (P products, only 26 were quantified. The novel action of tobacco heating and liquid aerosolisation produced classes and levels of toxicants that were similar to those of the control vapour product, but much lower than those of a Kentucky 3R4F reference cigarette. For nine toxicants mandated by the WHO Study Group on Tobacco Product Regulation for reduction in cigarette emissions, the levels were 91%-99% lower per puff in the hybrid tobacco product aerosol than in 3R4F smoke. Overall, the novel hybrid tobacco product provides a sensorially enhanced tobacco flavour, but maintains a toxicant profile similar to its parent vapour product with relatively low levels of known cigarette smoke toxicants. Copyright © 2017 British American Tobacco. Published by Elsevier Ltd.. All rights reserved.

  7. Middle atmospheric water vapour and dynamics in the vicinity of the polar vortex during the Hygrosonde-2 campaign

    Directory of Open Access Journals (Sweden)

    S. Lossow

    2009-07-01

    Full Text Available The Hygrosonde-2 campaign took place on 16 December 2001 at Esrange/Sweden (68° N, 21° E with the aim to investigate the small scale distribution of water vapour in the middle atmosphere in the vicinity of the Arctic polar vortex. In situ balloon and rocket-borne measurements of water vapour were performed by means of OH fluorescence hygrometry. The combined measurements yielded a high resolution water vapour profile up to an altitude of 75 km. Using the characteristic of water vapour being a dynamical tracer it was possible to directly relate the water vapour data to the location of the polar vortex edge, which separates air masses of different character inside and outside the polar vortex. The measurements probed extra-vortex air in the altitude range between 45 km and 60 km and vortex air elsewhere. Transitions between vortex and extra-vortex usually coincided with wind shears caused by gravity waves which advect air masses with different water vapour volume mixing ratios.

    From the combination of the results from the Hygrosonde-2 campaign and the first flight of the optical hygrometer in 1994 (Hygrosonde-1 a clear picture of the characteristic water vapour distribution inside and outside the polar vortex can be drawn. Systematic differences in the water vapour concentration between the inside and outside of the polar vortex can be observed all the way up into the mesosphere. It is also evident that in situ measurements with high spatial resolution are needed to fully account for the small-scale exchange processes in the polar winter middle atmosphere.

  8. Personal exposure to inhalable cement dust among construction workers

    International Nuclear Information System (INIS)

    Peters, Susan; Kromhout, Hans; Thomassen, Yngvar; Fechter-Rink, Edeltraud

    2009-01-01

    A case study was carried out in 2006-2007 to assess the actual cement dust exposure among construction workers involved in a full-scale construction project and as a comparison among workers involved in various stages of cement and concrete production. Full-shift personal exposure measurements were performed for several job types. Inhalable dust and cement dust (based on analysis of elemental calcium) concentrations were determined. Inhalable dust exposures at the construction site ranged from 0.05 to 34 mg/m3, with a mean concentration of 1.0 mg/m3. For inhalable cement dust mean exposure was 0.3 mg/m3 (range 0.02-17 mg/m3). Reinforcement and pouring workers had the lowest average concentrations. Inhalable dust levels in the ready-mix and pre-cast concrete plants were, on average, below 0.5 mg/m3 for inhalable dust and below 0.2 mg/m3 for inhalable cement dust. Highest dust concentrations were measured in cement production, particularly during cleaning tasks (inhalable dust GM=55 mg/m3; inhalable cement dust GM=33 mg/m3) at which point the workers wore personal protective equipment. Elemental measurements showed highest but very variable cement percentages in the cement plant and very low percentages of cement during reinforcement work and pouring.

  9. Making ET AAS Determination Less Dependent on Vapourization ...

    African Journals Online (AJOL)

    NICO

    The quantification of the analytes in ET AAS is normally attained by the measurement and integration of transient absorbance. High degree of atomization and constant vapour transportation rate for the analyte atoms in the absorption volume are considered to be crucial to grant correctness of the measurements. However ...

  10. Erratum to: Measurement of copper vapour laser-induced ...

    Indian Academy of Sciences (India)

    Erratum to: Measurement of copper vapour laser-induced deformation of dielectric-coated mirror surface by. Michelson interferometer. A WAHID. ∗. , S KUNDU, J S B SINGH, A K SINGH, A KHATTAR,. S K MAURYA, J S DHUMAL and K DASGUPTA. Laser & Plasma Technology Division, Beam Technology Development ...

  11. Microstructural development in physical vapour-deposited partially stabilized zirconia thermal barrier coatings

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Y. H. (Center for Intelligent Processing of Materials, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609-2280 (United States)); Biederman, R.R. (Center for Intelligent Processing of Materials, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609-2280 (United States)); Sisson, R.D. Jr. (Center for Intelligent Processing of Materials, Worcester Polytechnic Institute, 100 Institute Road, Worcester, MA 01609-2280 (United States))

    1994-10-01

    The effects of processing parameters of physical vapour deposition on the microstructure of partially stabilized zirconia (PSZ) thermal barrier coatings have been experimentally investigated. Emphasis has been placed on the crystallographic texture of the PSZ coatings and the microstructure of the top surface of the PSZ coatings as well as the metal-ceramic interface. The variations in the deposition chamber temperature, substrate thickness, substrate rotation and vapour incidence angle resulted in the observation of significant differences in the crystallographic texture and microstructure of the PSZ coatings. ((orig.))

  12. A simple passive method of collecting water vapour for environmental tritium monitoring

    International Nuclear Information System (INIS)

    Iida, T.; Fukuda, H.; Ikebe, Y.; Yokoyama, S.

    1995-01-01

    To investigate the average behaviour of tritium in an atmospheric environment, it is necessary to collect water vapour in air over a long period at numerous locations. For the purpose of the study, the passive method was developed: this is handy, low-priced and could collect water vapour in air without motive power. This paper describes the characteristics of the passive collecting method, the performance of water collection in outdoor air and the measurements of tritium concentrations in water samples collected by the passive method. (author)

  13. Effect of Liquid/Vapour Maldistribution on the Performance of Plate Heat Exchanger Evaporators

    DEFF Research Database (Denmark)

    Jensen, Jonas Kjær; Kærn, Martin Ryhl; Ommen, Torben Schmidt

    2015-01-01

    Plate heat exchangers are often applied as evaporators in industrial refrigeration and heat pump systems. In the design and modelling of such heat exchangers the flow and liquid/vapour distribution is often assumed to be ideal. However, maldistribution may occur and will cause each channel...... to behave differently due to the variation of the mass flux and vapour quality. To evaluate the effect of maldistribution on the performance of plate heat exchangers, a numerical model is developed in which the mass, momentum and energy balances are applied individually to each channel, including suitable...... correlations for heat transfer and pressure drop. The flow distribution on both the refrigerant and secondary side is determined based on equal pressure drop while the liquid/vapour distribution is imposed to the model. Results show that maldistribution may cause up to a 25 % reduction of the overall heat...

  14. Aspergillus fumigatus viability drives allergic responses to inhaled conidia.

    Science.gov (United States)

    Nayak, Ajay P; Croston, Tara L; Lemons, Angela R; Goldsmith, W T; Marshall, Nikki B; Kashon, Michael L; Germolec, Dori R; Beezhold, Donald H; Green, Brett J

    2018-04-13

    Aspergillus fumigatus induced allergic airway disease has been shown to involve conidial germination in vivo but the immunological mechanisms remain uncharacterized. A subchronic murine exposure model was used to examine the immunological mediators that are regulated in response to either culturable or non-culturable A. fumigatus conidia. Female B6C3F1/N mice were repeatedly dosed via inhalation with 1 x 105 viable or heat inactivated conidia (HIC), twice a week for 13 weeks (26 exposures). Control mice inhaled HEPA-filtered air. The influence of A. fumigatus conidial germination on the pulmonary immunopathological outcomes was evaluated by flow cytometry analysis of cellular infiltration in the airways, assessment of lung mRNA expression, and quantitative proteomics and histopathology of whole lung tissue. Repeated inhalation of viable conidia, but not HIC, resulted in allergic inflammation marked by vascular remodeling, extensive eosinophilia, and accumulation of alternatively activated macrophages (AAMs) in the murine airways. More specifically, mice that inhaled viable conidia resulted in a mixed TH1 and TH2 (IL-13) cytokine response. Recruitment of eosinophils corresponded with increased Ccl11 transcripts. Furthermore, genes associated with M2 or alternatively activated macrophage polarization (e.g. Arg1, Chil3 and Retnla) were significantly upregulated in viable A. fumigatus exposed mice. In mice inhaling HIC, CD4+ T cells expressing IFN-γ (TH1) dominated the lymphocytic infiltration. Quantitative proteomics of the lung revealed metabolic reprogramming accompanied by mitochondrial dysfunction and endoplasmic reticulum stress stimulated by oxidative stress from repetitive microbial insult. Our studies demonstrate that A. fumigatus conidial viability in vivo is critical to the immunopathological presentation of chronic fungal allergic disease. Copyright © 2018. Published by Elsevier Inc.

  15. Remote sensing of water vapour profiles in the framework of the Total Carbon Column Observing Network (TCCON

    Directory of Open Access Journals (Sweden)

    M. Schneider

    2010-12-01

    Full Text Available We show that the near infrared solar absorption spectra recorded in the framework of the Total Carbon Column Observing Network (TCCON can be used to derive the vertical distribution of tropospheric water vapour. The resolution of the TCCON spectra of 0.02 cm−1 is sufficient for retrieving lower and middle/upper tropospheric water vapour concentrations with a vertical resolution of about 3 and 8 km, respectively. We document the good quality of the remotely-sensed profiles by comparisons with coincident in-situ Vaisala RS92 radiosonde measurements. Due to the high measurement frequency, the TCCON water vapour profile data offer novel opportunities for estimating the water vapour variability at different timescales and altitudes.

  16. Evaluation of Inhaler Techniques Among Asthma Patients Seen in ...

    African Journals Online (AJOL)

    hanumantp

    Drug inhalation is an important and a common mode of .... to evaluate the use of inhaler technique among asthma patients in a .... The median duration of the use of the inhalers is 24 ..... Scalabrini A, Cukier A. Incorrect application technique of.

  17. Estimation of inhaled airborne particle number concentration by subway users in Seoul, Korea.

    Science.gov (United States)

    Kim, Minhae; Park, Sechan; Namgung, Hyeong-Gyu; Kwon, Soon-Bark

    2017-12-01

    Exposure to airborne particulate matter (PM) causes several diseases in the human body. The smaller particles, which have relatively large surface areas, are actually more harmful to the human body since they can penetrate deeper parts of the lungs or become secondary pollutants by bonding with other atmospheric pollutants, such as nitrogen oxides. The purpose of this study is to present the number of PM inhaled by subway users as a possible reference material for any analysis of the hazards to the human body arising from the inhalation of such PM. Two transfer stations in Seoul, Korea, which have the greatest number of users, were selected for this study. For 0.3-0.422 μm PM, particle number concentration (PNC) was highest outdoors but decreased as the tester moved deeper underground. On the other hand, the PNC between 1 and 10 μm increased as the tester moved deeper underground and showed a high number concentration inside the subway train as well. An analysis of the particles to which subway users are actually exposed to (inhaled particle number), using particle concentration at each measurement location, the average inhalation rate of an adult, and the average stay time at each location, all showed that particles sized 0.01-0.422 μm are mostly inhaled from the outdoor air whereas particles sized 1-10 μm are inhaled as the passengers move deeper underground. Based on these findings, we expect that the inhaled particle number of subway users can be used as reference data for an evaluation of the hazards to health caused by PM inhalation. Copyright © 2017 Elsevier Ltd. All rights reserved.

  18. Orange-Pigmented Sputum as a Manifestation of Smoke Grenade Inhalation Injury.

    Science.gov (United States)

    Chatzivasiloglou, Fotini; Katsenos, Stamatis; Psara, Anthoula; Tsintiris, Konstantinos

    2016-01-01

    A 34-year-old man presented with scanty hemoptysis, orange-colored expectoration, and mild dyspnea. He was in an enclosed building taking part in a military training exercise inhaling an orange-colored smoke from a smoke grenade ignition. His symptoms developed immediately after the initial exposure but he sought medical assistance 20 hours later because of their persistence. Fiberoptic bronchoscopy was performed revealing diffuse inflammatory tracheobronchial tree with streaky orange-pigmented secretions in the trachea and both main-stem bronchi. Acute tracheobronchitis was diagnosed and the patient was treated with nebulized bronchodilators and intravenous corticosteroids showing complete recovery. To our knowledge, this is the first well-documented report of inhalation injury induced by a smoke bomb explosion including potassium chlorate oxidizer and Sudan I and presenting with orange-pigmented sputum production. Smoke inhalation injury is associated with significant morbidity and mortality. The heterogeneity of the smoke and the large variety of the resulting symptoms may be the reason why a definition, specific diagnostic criteria, and therapeutic guidelines are still lacking.

  19. Study of water vapour adsorption kinetics on aluminium oxide materials

    Science.gov (United States)

    Livanova, Alesya; Meshcheryakov, Evgeniy; Reshetnikov, Sergey; Kurzina, Irina

    2017-11-01

    Adsorbents on the basis of active aluminum oxide are still of demand on the adsorbent-driers market. Despite comprehensive research of alumina adsorbents, and currently is an urgent task to improve their various characteristics, and especially the task of increasing the sorption capacity. In the present work kinetics of the processes of water vapours' adsorption at room temperature on the surface of desiccant samples has been studied. It was obtained on the basis of bayerite and pseudoboehmite experimentally. The samples of pseudoboehmite modified with sodium and potassium ions were taken as study objects. The influence of an adsorbent's grain size on the kinetics of water vapours' adsorption was studied. The 0.125-0.25 mm and 0.5-1.0 mm fractions of this sample were used. It has been revealed that the saturation water vapor fine powder (0.125-0.25 mm) is almost twofold faster in comparison with the sample of fraction 0.5-1.0 mm due to the decrease in diffusion resistance in the pores of the samples when moving from the sample of larger fraction to the fine-dispersed sample. It has been established that the adsorption capacity of the pseudoboehmite samples, modified by alkaline ions, is higher by ˜40 %, than for the original samples on the basis of bayerite and pseudoboehmite.

  20. The oxidation of stainless steels in water vapour-oxygen mixtures. Design and development of an original equipment

    International Nuclear Information System (INIS)

    Uller, Leonardo.

    1981-02-01

    A device including a thermobalance placed in a tight housing has been conceived and built. This apparatus is suitable to submit metallic samples to the action of dry oxygen, deoxygenated water vapour or mixtures of water vapour and oxygen. The first results obtained with this device, at 600 0 C, and for a 18-10 stainless steel are: - in the presence of deoxygenated water vapour, one observes very fast oxidation kinetics, with a roughly parabolic law (K approximately equal to 3x10 -2 mg 2 .cm -4 .h -1 ); - the addition of oxygen from about 10 vpm onwards, induces an important initial slowing down of the kinetics; - the duration of this 'induction' period rises with increasing the oxygen content of the water vapour, but the protection of the alloy due to the action of oxygen remains temporary; - in another way, experiments begun with water vapour, were continued with pure oxygen, and reciprocally. During these 'mixed' experiments, the weight increases were continually recorded. A swift slowing down has been observed in the first case and an important acceleration in the second one [fr

  1. Nasal inhalation of budesonide from a spacer in children with perennial rhinitis and asthma

    DEFF Research Database (Denmark)

    Pedersen, W; Hjuler, Inga Merete; Bisgaard, H

    1998-01-01

    and asthma inhaled budesonide through the nose from a pressurized aerosol, attached to a spacer device, in a double-blind, placebo-controlled, crossover study. Compared with placebo, budesonide treatment resulted in a significant reduction of nasal symptoms (Pasthma symptoms (P...The standard treatment of allergic rhinitis and asthma consists of topical corticosteroids administered intranasally and inhaled through the mouth. Although this therapy is highly effective, and side-effects are few and mild, it may be possible further to improve the therapeutic index and patient...... compliance with the treatment. In the present study, we evaluated a nasal inhalation system used for the simultaneous treatment of rhinitis and asthma. In principle, it results in an airway deposition of the corticosteroid similar to that of inhaled allergens. Twenty-four children with perennial rhinitis...

  2. Inhalable desert dust, urban emissions, and potentially biotoxic metals in urban Saharan-Sahelian air

    Science.gov (United States)

    Garrison, Virginia H.; Majewski, Michael S.; Konde, Lassana; Wolf, Ruth E.; Otto, Richard D.; Tsuneoka, Yutaka

    2014-01-01

    Saharan dust incursions and particulates emitted from human activities degrade air quality throughout West Africa, especially in the rapidly expanding urban centers in the region. Particulate matter (PM) that can be inhaled is strongly associated with increased incidence of and mortality from cardiovascular and respiratory diseases and cancer. Air samples collected in the capital of a Saharan–Sahelian country (Bamako, Mali) between September 2012 and July 2013 were found to contain inhalable PM concentrations that exceeded World Health Organization (WHO) and US Environmental Protection Agency (USEPA) PM2.5 and PM10 24-h limits 58 – 98% of days and European Union (EU) PM10 24-h limit 98% of days. Mean concentrations were 1.2-to-4.5 fold greater than existing limits. Inhalable PM was enriched in transition metals, known to produce reactive oxygen species and initiate the inflammatory response, and other potentially bioactive and biotoxic metals/metalloids. Eroded mineral dust composed the bulk of inhalable PM, whereas most enriched metals/metalloids were likely emitted from oil combustion, biomass burning, refuse incineration, vehicle traffic, and mining activities. Human exposure to inhalable PM and associated metals/metalloids over 24-h was estimated. The findings indicate that inhalable PM in the Sahara–Sahel region may present a threat to human health, especially in urban areas with greater inhalable PM and transition metal exposure.

  3. Computer simulation study of the nematic-vapour interface in the Gay-Berne model

    Science.gov (United States)

    Rull, Luis F.; Romero-Enrique, José Manuel

    2017-06-01

    We present computer simulations of the vapour-nematic interface of the Gay-Berne model. We considered situations which correspond to either prolate or oblate molecules. We determine the anchoring of the nematic phase and correlate it with the intermolecular potential parameters. On the other hand, we evaluate the surface tension associated to this interface. We find a corresponding states law for the surface tension dependence on the temperature, valid for both prolate and oblate molecules.

  4. Personal exposure to inhalable cement dust among construction workers.

    Science.gov (United States)

    Peters, Susan; Thomassen, Yngvar; Fechter-Rink, Edeltraud; Kromhout, Hans

    2009-01-01

    Objective- A case study was carried out to assess cement dust exposure and its determinants among construction workers and for comparison among workers in cement and concrete production.Methods- Full-shift personal exposure measurements were performed and samples were analysed for inhalable dust and its cement content. Exposure variability was modelled with linear mixed models.Results- Inhalable dust concentrations at the construction site ranged from 0.05 to 34 mg/m(3), with a mean of 1.0 mg/m(3). Average concentration for inhalable cement dust was 0.3 mg/m(3) (GM; range 0.02-17 mg/m(3)). Levels in the ready-mix and pre-cast concrete plants were on average 0.5 mg/m(3) (GM) for inhalable dust and 0.2 mg/m(3) (GM) for inhalable cement dust. Highest concentrations were measured in cement production, particularly during cleaning tasks (inhalable dust GM = 55 mg/m(3); inhalable cement dust GM = 33 mg/m(3)) at which point the workers wore personal protective equipment. Elemental measurements showed highest but very variable cement percentages in the cement plant and very low percentages during reinforcement work and pouring. Most likely other sources were contributing to dust concentrations, particularly at the construction site. Within job groups, temporal variability in exposure concentrations generally outweighed differences in average concentrations between workers. 'Using a broom', 'outdoor wind speed' and 'presence of rain' were overall the most influential factors affecting inhalable (cement) dust exposure.Conclusion- Job type appeared to be the main predictor of exposure to inhalable (cement) dust at the construction site. Inhalable dust concentrations in cement production plants, especially during cleaning tasks, are usually considerably higher than at the construction site.

  5. Respirable versus inhalable dust sampling

    International Nuclear Information System (INIS)

    Hondros, J.

    1987-01-01

    The ICRP uses a total inhalable dust figure as the basis of calculations on employee lung dose. This paper was written to look at one aspect of the Olympic Dam dust situation, namely, the inhalable versus respirable fraction of the dust cloud. The results of this study will determine whether it is possible to use respirable dust figures, as obtained during routine monitoring to help in the calculations of employee exposure to internal radioactive contaminants

  6. Economic considerations in the use of inhaled anesthetic agents.

    Science.gov (United States)

    Golembiewski, Julie

    2010-04-15

    To describe the components of and factors contributing to the costs of inhaled anesthesia, basis for quantifying and comparing these costs, and practical strategies for performing pharmacoeconomic analyses and reducing the costs of inhaled anesthetic agents. Inhaled anesthesia can be costly, and some of the variable costs, including fresh gas flow rates and vaporizer settings, are potential targets for cost savings. The use of a low fresh gas flow rate maximizes rebreathing of exhaled anesthetic gas and is less costly than a high flow rate, but it provides less control of the level of anesthesia. The minimum alveolar concentration (MAC) hour is a measure that can be used to compare the cost of inhaled anesthetic agents at various fresh gas flow rates. Anesthesia records provide a sense of patterns of inhaled anesthetic agent use, but the amount of detail can be limited. Cost savings have resulted from efforts to reduce the direct costs of inhaled anesthetic agents, but reductions in indirect costs through shortened times to patient recovery and discharge following the judicious use of these agents are more difficult to demonstrate. The patient case mix, fresh gas flow rates typically used during inhaled anesthesia, availability and location of vaporizers, and anesthesia care provider preferences and practices should be taken into consideration in pharmacoeconomic evaluations and recommendations for controlling the costs of inhaled anesthesia. Understanding factors that contribute to the costs of inhaled anesthesia and considering those factors in pharmacoeconomic analyses and recommendations for use of these agents can result in cost savings.

  7. Anxiety symptoms in crack cocaine and inhalant users admitted to a psychiatric hospital in southern Brazil.

    Science.gov (United States)

    Zubaran, Carlos; Foresti, Katia; Thorell, Mariana Rossi; Franceschini, Paulo Roberto

    2013-01-01

    The occurrence of psychiatric comorbidity among individuals with crack or inhalant dependence is frequently observed. The objective of this study was to investigate anxiety symptoms among crack cocaine and inhalant users in southern Brazil. The study investigated two groups of volunteers of equal size (n=50): one group consisted of crack cocaine users, and the other group consisted of inhalant users. Research volunteers completed the Portuguese versions of the State-Trait Anxiety Inventory (STAI), Hamilton Anxiety Rating Scale (HAM-A), and Self-Report Questionnaire (SRQ). Both crack and inhalant users experience significant symptoms of anxiety. Inhalant users presented significantly more anxiety symptoms than crack users according to the HAM-A questionnaire only. In contrast to the results of the HAM-A, the STAI failed to demonstrate a significant difference between the two groups of substance users. SRQ scores revealed that crack and inhalants users had significant degrees of morbidity. A significant difference regarding anxiety symptomatology, especially state anxiety, was observed among inhalant and crack users. Anxiety and overall mental psychopathology were significantly correlated in this sample. The results indicate that screening initiatives to detect anxiety and additional psychiatric comorbidities among crack and inhalant users are feasible and relevant. Copyright © 2013 Elsevier Editora Ltda. All rights reserved.

  8. Leidenfrost vapour layer moderation of the drag crisis and trajectories of superhydrophobic and hydrophilic spheres falling in water

    KAUST Repository

    Vakarelski, Ivan Uriev; Chan, Derek Y C; Thoroddsen, Sigurdur T

    2014-01-01

    We investigate the dynamic effects of a Leidenfrost vapour layer sustained on the surface of heated steel spheres during free fall in water. We find that a stable vapour layer sustained on the textured superhydrophobic surface of spheres falling through 95 °C water can reduce the hydrodynamic drag by up to 75% and stabilize the sphere trajectory for the Reynolds number between 104 and 106, spanning the drag crisis in the absence of the vapour layer. For hydrophilic spheres under the same conditions, the transition to drag reduction and trajectory stability occurs abruptly at a temperature different from the static Leidenfrost point. The observed drag reduction effects are attributed to the disruption of the viscous boundary layer by the vapour layer whose thickness depends on the water temperature. Both the drag reduction and the trajectory stabilization effects are expected to have significant implications for development of sustainable vapour layer based technologies. © the Partner Organisations 2014.

  9. Inhalation of Simulated Smog Affects Cardiac Function in Mice

    Science.gov (United States)

    Rationale: The health effects of individual criteria air pollutants have been well investigated. Little is known about health effects of inhaled multi-pollutant mixtures that more realistically represent environmental exposures. The present study was designed to evaluate the card...

  10. Know How to Use Your Asthma Inhaler

    Medline Plus

    Full Text Available ... for Control Triggers Indoors In the Workplace Outdoors Management Asthma Action Plan Flu Shots Inhalers Data, Statistics, ... How to Use Your Asthma Inhaler Recommend on Facebook Tweet Share Compartir You can control your asthma ...

  11. Mercury Vapour Long-Lasting Exposure: Lymphocyte Muscarinic Receptors as Neurochemical Markers of Accidental Intoxication

    Directory of Open Access Journals (Sweden)

    E. Roda

    2016-01-01

    Full Text Available Introduction. Chronic poisoning may result in home setting after mercury (Hg vapours inhalation from damaged devices. We report a chronic, nonoccupational Hg poisoning due to 10-year indoor exposure to mercury spillage. Case Report. A 72-year-old man with polyneuropathy of suspected toxic origin. At hospitalization, toxicological clinical evaluations confirmed the altered neurological picture documented across the last decade. Periodic blood and urine Hg levels (BHg, UHg monitoring were performed from admission (t0, until 1 year later (t2, paralleled by blood neurochemical markers assessment, that is, lymphocytes muscarinic receptors (l-MRs. At t0: BHg and UHg were 27 and 1.4 microg/L, respectively (normal values: BHg 1–4.5; UHg 0.1–4.5, associated with l-MRs increase, 185.82 femtomoL/million lymphocytes (normal range: 8.0–16.0. At t1 (two days after DMSA-mobilization test, BHg weak reduction, paralleled by UHg 3.7-fold increase, was measured together with further l-MRs enhancement (205.43 femtomoL/million lymphocytes. At t2 (eight months after two cycles of DMSA chelating therapy ending, gradual improving of clinical manifestations was accompanied by progressive decrease of BHg and UHg (4.0 and 2.8 microg/L, resp. and peripheral l-MRs neurochemical marker (24.89 femtomoL/million lymphocytes. Conclusion. l-MRs modulatory effect supports their use as peripheral neurochemical marker in Hg poisoning diagnosis and chelation therapy monitoring.

  12. The use of multiple respiratory inhalers requiring different inhalation techniques has an adverse effect on COPD outcomes

    Directory of Open Access Journals (Sweden)

    Bosnic-Anticevich S

    2016-12-01

    Full Text Available Sinthia Bosnic-Anticevich,1 Henry Chrystyn,2 Richard W Costello,3,4 Myrna B Dolovich,5 Monica J Fletcher,6 Federico Lavorini,7 Roberto Rodríguez-Roisin,8 Dermot Ryan,9,10 Simon Wan Yau Ming,2 David B Price2,11 1Woolcock Institute of Medical Research, School of Medical Sciences, University of Sydney and Sydney Local Health District, Sydney, NSW, Australia; 2Observational and Pragmatic Research Institute Pte Ltd, Singapore; 3RCSI Medicine, Royal College of Surgeons, 4RCSI Education & Research Centre, Beaumont Hospital, Beaumont, Dublin, Ireland; 5Department of Medicine, Respirology, McMaster University, ON, Canada; 6Education for Health, Warwick, UK; 7Department of Experimental and Clinical Medicine, University of Florence, Florence, Italy; 8Respiratory Institute, Hospital Clinic, Universitat de Barcelona, Barcelona, Spain; 9Optimum Patient Care, Cambridge, 10Centre for Population Health Sciences, University of Edinburgh, Edinburgh, 11Academic Primary Care, University of Aberdeen, Aberdeen, UK Background: Patients with COPD may be prescribed multiple inhalers as part of their treatment regimen, which require different inhalation techniques. Previous literature has shown that the effectiveness of inhaled treatment can be adversely affected by incorrect inhaler technique. Prescribing a range of device types could worsen this problem, leading to poorer outcomes in COPD patients, but the impact is not yet known. Aims: To compare clinical outcomes of COPD patients who use devices requiring similar inhalation technique with those who use devices with mixed techniques. Methods: A matched cohort design was used, with 2 years of data from the Optimum Patient Care Research Database. Matching variables were established from a baseline year of follow-up data, and two cohorts were formed: a “similar-devices cohort” and a “mixed-devices cohort”. COPD-related events were recorded during an outcome year of follow-up. The primary outcome measure was an

  13. Inhalation drug delivery devices: technology update

    Directory of Open Access Journals (Sweden)

    Ibrahim M

    2015-02-01

    Full Text Available Mariam Ibrahim, Rahul Verma, Lucila Garcia-ContrerasDepartment of Pharmaceutical Sciences, College of Pharmacy, The University of Oklahoma Health Sciences Center, Oklahoma City, OK, USAAbstract: The pulmonary route of administration has proven to be effective in local and systemic delivery of miscellaneous drugs and biopharmaceuticals to treat pulmonary and non-pulmonary diseases. A successful pulmonary administration requires a harmonic interaction between the drug formulation, the inhaler device, and the patient. However, the biggest single problem that accounts for the lack of desired effect or adverse outcomes is the incorrect use of the device due to lack of training in how to use the device or how to coordinate actuation and aerosol inhalation. This review summarizes the structural and mechanical features of aerosol delivery devices with respect to mechanisms of aerosol generation, their use with different formulations, and their advantages and limitations. A technological update of the current state-of-the-art designs proposed to overcome current challenges of existing devices is also provided.Keywords: pulmonary delivery, asthma, nebulizers, metered dose inhaler, dry powder inhaler

  14. Inhaled ciclesonide versus inhaled budesonide or inhaled beclomethasone or inhaled fluticasone for chronic asthma in adults: a systematic review

    Directory of Open Access Journals (Sweden)

    Halpin David MG

    2006-06-01

    Full Text Available Abstract Background Ciclesonide is a new inhaled corticosteroids licensed for the prophylactic treatment of persistent asthma in adults. Currently beclomethasone dipropionate, budesonide and fluticasone propionate are the most commonly prescribed inhaled corticosteroids for the treatment of asthma but there has been no systematic review comparing the effectiveness and safety ciclesonide to these agents. We therefore aimed to systematically review published randomised controlled trials of the effectiveness and safety of ciclesonide compared to alternative inhaled corticosteroids in people with asthma. Methods We performed literature searches on MEDLINE, EMBASE, PUBMED, the COCHRANE LIBRARY and various Internet evidence sources for randomised controlled trials or systematic reviews comparing ciclesonide to beclomethasone or budesonide or fluticasone in adult humans with persistent asthma. Data was extracted by one reviewer. Results Five studies met the inclusion criteria. Methodological quality was variable. There were no trials comparing ciclesonide to beclomethasone. There was no significant difference between ciclesonide and budesonide or fluticasone on the following outcomes: lung function, symptoms, quality of life, airway responsiveness to a provoking agent or inflammatory markers. However, the trials were very small in size, increasing the possibility of a type II error. One trial demonstrated that the combined deposition of ciclesonide (and its active metabolite in the oropharynx was 47% of that of budesonide while another trial demonstrated that the combined deposition of ciclesonide (and its active metabolite in the oropharynx was 53% of that of fluticasone. One trial demonstrated less suppression of cortisol in overnight urine collection after ciclesonide compared to fluticasone (geometric mean fold difference = 1.5, P Conclusion There is very little evidence comparing CIC to other ICS, restricted to very small, phase II studies of low

  15. DESIGN of MICRO CANTILEVER BEAM for VAPOUR DETECTION USING COMSOL MULTI PHYSICS SOFTWARE

    OpenAIRE

    Sivacoumar R; Parvathy JM; Pratishtha Deep

    2015-01-01

    This paper gives an overview of micro cantilever beam of various shapes and materials for vapour detection. The design of micro cantilever beam, analysis and simulation is done for each shape. The simulation is done using COMSOL Multi physics software using structural mechanics and chemical module. The simulation results of applied force and resulting Eigen frequencies will be analyzed for different beam structures. The vapour analysis is done using flow cell that consists of chemical pill...

  16. Vapour pressures and enthalpies of vaporization of a series of the ferrocene derivatives

    International Nuclear Information System (INIS)

    Emel'yanenko, Vladimir N.; Verevkin, Sergey P.; Krol, Olesya V.; Varushchenko, Raisa M.; Chelovskaya, Nelly V.

    2007-01-01

    Vapour pressures of the ferrocene, ferrocene-methanol, benzyl-ferrocene, and benzoyl-ferrocene have been determined by the transpiration method. The molar enthalpies of sublimation Δ cr g H m and of vaporization Δ l g H m have been determined from the temperature dependence of the vapour pressure. The molar enthalpies of fusion of these compounds were measured by d.s.c. The measured data sets of vaporization, sublimation, and fusion enthalpies were checked for internal consistency

  17. Thermodynamic properties of the liquid Hg-Tl alloys determined from vapour pressure measurements

    Directory of Open Access Journals (Sweden)

    Gierlotka W.

    2002-01-01

    Full Text Available The partial vapour pressure of mercury over liquid Hg-Tl liquid solutions were determined in the temperature range from 450 to 700 K by direct vapour pressure measurements carried out with the quartz gauge. From the measured ln pHg vs. T relationships activities of mercury were determined. Using Redlich-Kister formulas logarithms of the activity coefficients were described with the following equations: From which all thermodynamic functions in the solutions can be derived.

  18. Characterization of aqueous interactions of copper-doped phosphate-based glasses by vapour sorption.

    Science.gov (United States)

    Stähli, Christoph; Shah Mohammadi, Maziar; Waters, Kristian E; Nazhat, Showan N

    2014-07-01

    Owing to their adjustable dissolution properties, phosphate-based glasses (PGs) are promising materials for the controlled release of bioinorganics, such as copper ions. This study describes a vapour sorption method that allowed for the investigation of the kinetics and mechanisms of aqueous interactions of PGs of the formulation 50P2O5-30CaO-(20-x)Na2O-xCuO (x=0, 1, 5 and 10mol.%). Initial characterization was performed using (31)P magic angle spinning nuclear magnetic resonance and attenuated total reflectance-Fourier transform infrared spectroscopy. Increasing CuO content resulted in chemical shifts of the predominant Q(2) NMR peak and of the (POP)as and (PO(-)) Fourier transform infrared absorptions, owing to the higher strength of the POCu bond compared to PONa. Vapour sorption and desorption were gravimetrically measured in PG powders exposed to variable relative humidity (RH). Sorption was negligible below 70% RH and increased exponentially with RH from 70 to 90%, where it exhibited a negative correlation with CuO content. Vapour sorption in 0% and 1% CuO glasses resulted in phosphate chain hydration and hydrolysis, as evidenced by protonated Q(0)(1H) and Q(1)(1H) species. Dissolution rates in deionized water showed a linear correlation (R(2)>0.99) with vapour sorption. Furthermore, cation release rates could be predicted based on dissolution rates and PG composition. The release of orthophosphate and short polyphosphate species corroborates the action of hydrolysis and was correlated with pH changes. In conclusion, the agreement between vapour sorption and routine characterization techniques in water demonstrates the potential of this method for the study of PG aqueous reactions. Copyright © 2014 Acta Materialia Inc. Published by Elsevier Ltd. All rights reserved.

  19. INDOOR AIR QUALITY AND INHALATION EXPOSURE - SIMULATION TOOL KIT

    Science.gov (United States)

    A Microsoft Windows-based indoor air quality (IAQ) simulation software package is presented. Named Simulation Tool Kit for Indoor Air Quality and Inhalation Exposure, or IAQX for short, this package complements and supplements existing IAQ simulation programs and is desi...

  20. WATER VAPOUR PERMEABILITY PROPERTIES OF CELLULAR WOOD MATERIAL AND CONDENSATION RISK OF COMPOSITE PANEL WALLS

    Directory of Open Access Journals (Sweden)

    Janis IEJAVS

    2016-09-01

    Full Text Available Invention of light weight cellular wood material (CWM with a trade mark of Dendrolight is one of innovations in wood industry of the last decade. The aim of the research was to define the water vapour permeability properties of CWM and to analyse the condensation risk of various wall envelopes where solid wood cellular material is used. To determine the water vapour permeability of CWM, test samples were produced in the factory using routine production technology and tested according to the standard EN 12086:2014. Water vapour permeability factor (μ and other properties of six different configurations of CWM samples were determined. Using the experimental data the indicative influence of geometrical parameters such as lamella thickness, number of lamellas and material direction were investigated and evaluated. To study the condensation risk within the wall envelope containing CWM calculation method given in LVS EN ISO 13788:2012 was used. To ease the calculation process previously developed JavaScript calculation software that had only capability to calculate thermal transmittance was extended so that condensation risk in multi-layer composite walls can be analysed. Water vapour permeability factor in CWM is highly direction dependant. If parallel and perpendicular direction of CWM is compared the value of water vapour permeability factor can differentiate more than two times. Another significant factor for condensation risk analysis is overall thickness of CWM since it directly influences the equivalent air layer thickness. The influence of other factors such as lamella thickness, or groove depth is minor when water vapour permeability properties are compared. From the analysis of CWM performance in building envelope it can be concluded that uninsulated CWM panels used during winter months will pose the risk of condensation damage to structure, but the risk can be reduced or prevented if insulation layer is applied to the CWM panel wall

  1. Inhalation Toxicology Research Institute annual report 1987-1988

    International Nuclear Information System (INIS)

    Mauderly, J.L.; Mewhinney, J.A.; Bechtold, W.E.; Sun, J.D.; Coons, T.A.

    1988-12-01

    The mission of the Inhalation Toxicology Research Institute is to investigate the magnitude of human health effects that result from the inhalation of airborne materials at home, in the work place, or in the general environment. Diseases of the respiratory tract are major causes of suffering and death, and many of these diseases are directly related to the materials that people breath. The Institute's research is directed toward obtaining a better understanding of the basic biology of the respiratory tract and the mechanisms by which inhaled materials produce respiratory disease. Special attention is focused on studying the airborne materials released by various energy technologies, as well as those associated with national defense activities. The research uses a wide-ranging, comprehensive array of investigative approaches that are directed toward characterizing the source of the airborne material, following the material through its potential transformation in the air, identifying the mechanisms that govern its inhalation and deposition in the respiratory tract, and determining the fate of these inhaled materials in the body and the health effects they produce. The ultimate objectives are to determine the roles played by inhaled materials in the development of disease processes adn to estimate the risk they pose by inhaled materials in the development of disease processes and to estimate the risk they pose to humans who may be exposed to them. This report contains brief research papers that reflect the scope and recent findings of the Institute's research funded by the U.S. Department of Energy, principally through the Office of Health and Environmental Research. The papers are divided into topical sections. The first section, Characterization of Airborne Materials and Generation of Experimental Exposure Atmospheres, reflects the Institute's capabilities for fundamental aerosol research and the application of that expertise to toxicological studies. The second

  2. Inhalation Toxicology Research Institute annual report 1987-1988

    Energy Technology Data Exchange (ETDEWEB)

    Mauderly, J L; Mewhinney, J A; Bechtold, W E; Sun, J D; Coons, T A [eds.

    1988-12-01

    The mission of the Inhalation Toxicology Research Institute is to investigate the magnitude of human health effects that result from the inhalation of airborne materials at home, in the work place, or in the general environment. Diseases of the respiratory tract are major causes of suffering and death, and many of these diseases are directly related to the materials that people breath. The Institute's research is directed toward obtaining a better understanding of the basic biology of the respiratory tract and the mechanisms by which inhaled materials produce respiratory disease. Special attention is focused on studying the airborne materials released by various energy technologies, as well as those associated with national defense activities. The research uses a wide-ranging, comprehensive array of investigative approaches that are directed toward characterizing the source of the airborne material, following the material through its potential transformation in the air, identifying the mechanisms that govern its inhalation and deposition in the respiratory tract, and determining the fate of these inhaled materials in the body and the health effects they produce. The ultimate objectives are to determine the roles played by inhaled materials in the development of disease processes adn to estimate the risk they pose by inhaled materials in the development of disease processes and to estimate the risk they pose to humans who may be exposed to them. This report contains brief research papers that reflect the scope and recent findings of the Institute's research funded by the U.S. Department of Energy, principally through the Office of Health and Environmental Research. The papers are divided into topical sections. The first section, Characterization of Airborne Materials and Generation of Experimental Exposure Atmospheres, reflects the Institute's capabilities for fundamental aerosol research and the application of that expertise to toxicological studies. The second

  3. Review of reports by J.W. Gofman on inhaled plutonium

    International Nuclear Information System (INIS)

    Bair, W.J.

    1975-01-01

    Two recent widely circulated reports on the subject of inhaled plutonium have provoked concern among the press and in Congress. These reports, The Cancer Hazard from Inhaled Plutonium, CNR Report 1975-1R, May 14, 1975, and Estimated Production of Human Lung Cancers by Plutonium from Worldwide Fallout, CNR Report 1975-2, July 10, 1975, were written by John W. Gofman and issued by the Committee for Nuclear Responsibility, P. O. Box 2329, Dublin, California 94566. Gofman's reports do not present an objective analysis of the hazard of inhaled plutonium; his arguments, in fact, contradict many conclusions drawn in the scientific literature and supported by experimental data. Because the reports are skillfully written, however, they could easily mislead readers who are not well versed in this area. The purpose of this review, therefore, is to examine Gofman's reports in the light of recent research studies and to identify errors of fact and logic in his arguments

  4. A research of vapour-film characteristics of inverted-annular flow film boiling by visual method

    International Nuclear Information System (INIS)

    Xu Jijun; Guo Zhichao; Yan An; Bi Haoran

    1988-01-01

    The vapour-film characteristics are an interesting topic in inverted-annular flow film boiling. A practical set of experimental rig has been designed and constructed for visual observation. Photographic method is adopted for obtaining number of photographs in the conditions of steady state. For references at hands, photographs under steady conditions of water flow film boiling have not been published yet. This paper discusses the typical vapour film characteristics and regards Elias' two-region model summarized from transient visual experiment as reasonable. In addition, under heated conditions, at least, three types of vapour-water interfaces have been observed. They are asymmetric sine waves, symmetic varicose waves, and roll waves offered by Jarlais from an adiabatic simulation. In diabatic conditions a transition of flow pattern to slug flow is usually caused by hydrodynamic instability and/or by thermodynamic instability. The effects of mass velocity, inlet subcooling, heat flux input, initial quality and pressure to vapour-film characteristics are described. An empirical correlation is fitted to 23 sets of tests of discussion

  5. Pharmacological Characterization of the Discriminative Stimulus of Inhaled 1,1,1-Trichloroethane

    OpenAIRE

    Shelton, Keith L.

    2010-01-01

    The present study examined the involvement of the GABAA, N-methy-d-aspartate (NMDA), nicotinic acetylcholine, and μ-opioid receptor systems in the transduction of the discriminative stimulus effects of the abused inhalant 1,1,1-trichloroethane (TCE). Sixteen B6SJLF1/J mice were trained to discriminate 10 min of exposure to 12,000-ppm inhaled TCE vapor from air. Substitution and antagonism tests and TCE blood concentration analysis were subsequently conducted. TCE blood concentrations decrease...

  6. Cromolyn Oral Inhalation

    Science.gov (United States)

    ... your doctor.Cromolyn oral inhalation helps to prevent asthma attacks (sudden episodes of shortness of breath, wheezing, and coughing) but will not stop an asthma attack that has already started. Your doctor will prescribe ...

  7. Olodaterol Oral Inhalation

    Science.gov (United States)

    ... in a class of medications called long-acting beta-agonists (LABAs). It works by relaxing and opening ... the inhaler upright with the yellow cap closed. Turn the clear base in the direction of the ...

  8. Ipratropium Oral Inhalation

    Science.gov (United States)

    ... with the clear end pointing upward. Place the metal canister inside the clear end of the inhaler. ... do not discard it in an incinerator or fire.Unneeded medications should be disposed of in special ...

  9. Nicotine content of electronic cigarettes, its release in vapour and its consistency across batches: regulatory implications.

    Science.gov (United States)

    Goniewicz, Maciej L; Hajek, Peter; McRobbie, Hayden

    2014-03-01

    Electronic cigarettes (EC) may have a potential for public health benefit as a safer alternative to smoking, but questions have been raised about whether EC should be licensed as a medicine, with accurate labelling of nicotine content. This study determined the nicotine content of the cartridges of the most popular EC brands in the United Kingdom and the nicotine levels they deliver in the vapour, and estimated the safety and consistency of nicotine delivery across batches of the same product as a proxy for quality control for individual brands and within the industry. We studied five UK brands (six products) with high internet popularity. Two samples of each brand were purchased 4 weeks apart, and analysed for nicotine content in the cartridges and nicotine delivery in vapour. The nicotine content of cartridges within the same batch varied by up to 12% relative standard deviation (RSD) and the mean difference between different batches of the same brand ranged from 1% [95% confidence interval (CI) = -5 to 7%] to 20% (95% CI=14-25%) for five brands and 31% (95% CI=21-39%) for the sixth. The puffing schedule used in this study vaporized 10-81% of the nicotine present in the cartridges. The nicotine delivery from 300 puffs ranged from ∼2 mg to ∼15 mg and was not related significantly to the variation of nicotine content in e-liquid (r=0.06, P=0.92). None of the tested products allowed access to e-liquid or produced vapour nicotine concentrations as high as conventional cigarettes. There is very little risk of nicotine toxicity from major electronic cigarette (EC) brands in the United Kingdom. Variation in nicotine concentration in the vapour from a given brand is low. Nicotine concentration in e-liquid is not well related to nicotine in vapour. Other EC brands may be of lower quality and consumer protection regulation needs to be implemented, but in terms of accuracy of labelling of nicotine content and risks of nicotine overdose, regulation over and above

  10. Development and evaluation of an inhalation chamber for in vivo tests

    Directory of Open Access Journals (Sweden)

    EDUARDO R. DA SILVA

    2017-08-01

    Full Text Available ABSTRACT The bioavailability, toxicity, and therapeutic efficacy of a drug is directly related to its administration route. The pulmonary route can be accessed by inhalation after fumigation, vaporization or nebulization. Thus, pharmacological and toxicological evaluation accessed by an apparatus specifically designed and validated for this type of administration is extremely important. Based on pre-existing models, an inhalation chamber was developed. This presents a central structure with five animal holders. The nebulized air passes directly and continuously through these holders and subsequently to an outlet. Evaluation of its operation was performed using clove essential oil, a nebulizer, and a flow meter. The air within the chamber was collected by static headspace and analyzed by gas chromatography with a flame ionization detector. For this purpose, a 2.5 minutes chromatographic method was developed. The air flow in each of the five outputs was 0.92 liters per minute. During the first minute, the chamber became saturated with the nebulized material. Homogeneous and continuous operation of the chamber was observed without accumulation of volatile material inside it for 25 minutes. The inhalation chamber works satisfactorily for in vivo tests with medicines designed to be administrated by inhalation.

  11. Late effects of inhaled 253Es(NO3)3 in rats

    International Nuclear Information System (INIS)

    Ballou, J.E.; Dagle, G.E.; Gies, R.A.; Smith, L.G.

    1979-01-01

    Einsteinium-253 nitrate was administered as an aerosol to male Wistar rats and the long-term biological effects were followed for the animals' life span. Lung was the major target organ for absorbed radiation dose and tumor induction, in agreement with results for other inhaled transuranic nitrates. The earlier finding of a high incidence of bone tumors following intratracheal instillation of 253 EsCl 3 was not confirmed in the present study with inhaled 253 Es(NO 3 ) 3 . The reason for the difference in bone tumor production is believed to be related to the different acute toxicities of intratracheally instilled and inhaled 253 Es. Intratracheally instilled 253 EsCl 3 was less acutely toxic (only a single lobe or one-half the lung was irradiated); thus, a larger more tumorigenic dose could be translocated to bone without shortening the life span to the extent that bone tumors could not be expressed. The radiation dose from inhaled 253 Es(NO 3 ) 3 was uniformly spread throughout both lungs and early death due to a generalized radiation pneumonitis precluded the development of long-term effects in bone. (author)

  12. Efficient quantification of water content in edible oils by headspace gas chromatography with vapour phase calibration.

    Science.gov (United States)

    Xie, Wei-Qi; Gong, Yi-Xian; Yu, Kong-Xian

    2018-06-01

    An automated and accurate headspace gas chromatographic (HS-GC) technique was investigated for rapidly quantifying water content in edible oils. In this method, multiple headspace extraction (MHE) procedures were used to analyse the integrated water content from the edible oil sample. A simple vapour phase calibration technique with an external vapour standard was used to calibrate both the water content in the gas phase and the total weight of water in edible oil sample. After that the water in edible oils can be quantified. The data showed that the relative standard deviation of the present HS-GC method in the precision test was less than 1.13%, the relative differences between the new method and a reference method (i.e. the oven-drying method) were no more than 1.62%. The present HS-GC method is automated, accurate, efficient, and can be a reliable tool for quantifying water content in edible oil related products and research. © 2017 Society of Chemical Industry. © 2017 Society of Chemical Industry.

  13. Inhaled Antibiotics in Reanimatology: Problem State and Development Prospects (Review

    Directory of Open Access Journals (Sweden)

    A. N. Kuzovlev

    2017-01-01

    Full Text Available Nosocomial pneumonia is the second most common nosocomial infection in critical care units and most common in ALV patients (9—27%. The purpose of this literature review is to discuss the latest domestic and foreign body of evidence concerning the use of inhaled antibiotics в critical care. Search for domestic publications (literature reviews, observation studies, double blind randomized studies was carried out in elibrary.ru database, for foreign — in PubMed. Database for the period of yrs. 2005—2017. The following search enquiries were used: «inhaled antibiotics», «nosocomial pneumonia», «inhaled tobramycin», «inhaled colistin». The analysis includes 67 publications of yrs. 2007—2017 and 1 publication of yr. 2000. The literature review includes drug descriptions, contemporary capabilities of inhaled antibiotic therapy for nosocomial pneumonia, the advantages and drawbacks of this method of treatment. Special attention is focused on the use of inhaled aminoglycosides and inhaled colistin during nosocomial pneumonia in critical care units.

  14. Thermodynamic study of multi-effect thermal vapour-compression desalination systems

    International Nuclear Information System (INIS)

    Samaké, Oumar; Galanis, Nicolas; Sorin, Mikhail

    2014-01-01

    The parametric analysis of a multi-effect-evaporation (MEE) desalination system combined with a thermal-vapour-compression (TVC) process activated by a gaseous stream of specified flowrate and temperature was performed based on the principles of classical (1st and 2nd laws) and finite-size thermodynamics. The MEE subsystem was treated as a black box and therefore the results are valid for any combination of physical characteristics and internal operational conditions of this subsystem. They show the effects of four design variables (the motive fluid pressure and the compression ratio of the ejector, the condenser temperature pinch and the ratio of rejected to supplied seawater) on significant operating quantities and performance indicators such as: energy supplied by the heat source; motive fluid flowrate; flowrates of the supplied seawater and produced potable water; specific heat consumption; thermal conductance of the vapour generator and the condenser; exergy destruction by the MEE, the ejector and the vapour generator. Based on the obtained results recommendations are formulated for the optimal choice of values for the four design variables. - Highlights: • Model of a MEE-TVC desalination system independent of MEE characteristics. • Parametric study based on classical (1st and 2nd law) and finite-size thermodynamics. • Effect of 4 design parameters on operating conditions and performance indicators. • Recommended values for the design parameters

  15. Application of cylinder symmetry to iron and titanium oxidation by oxygen or hydrogen-water vapour mixes

    International Nuclear Information System (INIS)

    Raynaud, Pierre

    1980-01-01

    This research thesis addresses the study of the oxidation reaction in the case of corrosion of iron by oxygen, hydrogen sulphide or hydrogen-water vapour mixes, and in the case of oxidation of titanium and of titanium nitride by hydrogen-water vapour mixes. It first addresses the corrosion of iron by oxygen with an experiment performed in cylinder symmetry: description of operational conditions, discussion of kinetic curves, development of a law of generation of multiple layers in cylinder symmetry, analytical exploitation of experimental results. The second part addresses the oxidation of iron by hydrogen-water vapour mixes: experimental conditions, influence of temperature on kinetics, micrographic study (oxide morphology, coating morphology, interpretation of differences with the case of plane symmetry), discussion of the influence of cylinder symmetry on oxidation kinetics. The third part addresses the oxidation of titanium by hydrogen-water vapour mixes: global kinetic evolution, reaction products and micrographic examination, morphology and texture studies, discussion of the oxidation mechanism and of cylinder symmetry [fr

  16. Measurement and modeling of high-pressure (vapour + liquid) equilibria of (CO{sub 2} + alcohol) binary systems

    Energy Technology Data Exchange (ETDEWEB)

    Gutierrez, Jorge E.; Bejarano, Arturo [Departamento de Ingenieria Quimica y Ambiental, Universidad Tecnica Federico Santa Maria, Avda. Espana 1680, Valparaiso (Chile); Fuente, Juan C. de la, E-mail: juan.delafuente@usm.c [Departamento de Ingenieria Quimica y Ambiental, Universidad Tecnica Federico Santa Maria, Avda. Espana 1680, Valparaiso (Chile); Centro Regional de Estudios en Alimentos Saludables, Blanco 1623, Valparaiso (Chile)

    2010-05-15

    An apparatus based on a static-analytic method assembled in this work was utilized to perform high pressure (vapour + liquid) equilibria measurements with uncertainties estimated at <5%. Complementary isothermal (vapour + liquid) equilibria results are reported for the (CO{sub 2} + 1-propanol), (CO{sub 2} + 2-methyl-1-propanol), (CO{sub 2} + 3-methyl-1-butanol), and (CO{sub 2} + 1-pentanol) binary systems at temperatures of (313, 323, and 333) K, and at pressure range of (2 to 12) MPa. For all the (CO{sub 2} + alcohol) systems, it was visually monitored to insure that there was no liquid immiscibility at the temperatures and pressures studied. The experimental results were correlated with the Peng-Robinson equation of state using the quadratic mixing rules of van der Waals with two adjustable parameters. The calculated (vapour + liquid) equilibria compositions were found to be in good agreement with the experimental values with deviations for the mol fractions <0.12 and <0.05 for the liquid and vapour phase, respectively.

  17. Nicotine Oral Inhalation

    Science.gov (United States)

    ... with a smoking cessation program, which may include support groups, counseling, or specific behavioral change techniques. Nicotine inhalation ... and pharmacist what prescription and nonprescription medications, vitamins, nutritional supplements, and herbal products you are taking or ...

  18. Heat transfer in vapour-liquid flow of carbon dioxide

    International Nuclear Information System (INIS)

    Yagov, V.V.

    2009-01-01

    During the last decade a number of studies of boiling heat transfer in carbon dioxide notably increase. As a field of CO 2 practical using corresponds to high reduced pressures, and a majority of available experimental data on CO 2 flow boiling even in submillimetric channels relate to turbulent liquid flow regimes, a possibility arises to develop sufficiently general method for HTC predicting. Under the above conditions nucleate boiling occurs up to rather high flow quality, even in annular flow regime due to extremely small size of an equilibrium vapour bubble. This conclusion is in agreement with the available experimental data. The predicting equation for nucleate boiling heat transfer developed by the present author in 1988 is valid for any nonmetallic liquid. A contribution of forced convection in heat transfer is calculated according to the Petukhov et al. equation with correction factor, which accounted for an effect of velocity increase due to evaporation. This effect can be essential at relatively small heat fluxes and rather high mass flow rates. The Reynolds analogy and homogeneous model are used in order to account for the convective heat transfer augmentation in two-phase flow. Due to low ratio of liquid and vapour densities at high reduced pressures the homogeneous approximation of two-phase flow seems to be warranted. A total heat transfer coefficient is calculated as an interpolated value of boiling and convective HTCs. The experimental data on CO 2 flow boiling related to regimes before heated wall dryout incipience are in rather good agreement with the calculations. (author)

  19. 3D imaging of vapour and liquid inclusions from the Mole Granite, Australia, using helical fluorescence tomography

    Energy Technology Data Exchange (ETDEWEB)

    Cauzid, J. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex (France)], E-mail: jean.cauzid@esrf.fr; Philippot, P. [Geobiosphere Actuelle et Primitive, Institut de Physique du Globe de Paris, CNRS and Universite Denis Diderot, Case 89, 4 place Jussieu, 75252 Paris Cedex 05 (France); Bleuet, P. [European Synchrotron Radiation Facility, 6 rue Jules Horowitz, BP 220, 38043 Grenoble Cedex (France); Simionovici, A. [Laboratoire de Geophysique Interne et Tectonophysique, BP 53, 38041 Grenoble Cedex 9 (France); Somogyi, A. [Synchrotron Soleil, DiffAbs beamline, Saint-Aubin, BP 48, 91192 Gif-sur-Yvette Cedex (France); Golosio, B. [Instituto di Matematica e Fisica, Universita di Sassari, 2 via Vienna, 07100 Sassari (Italy)

    2007-08-15

    World class Cu resources are concentrated in porphyry and epithermal ore deposits. Their formation remains partially understood, however, due to a lack of constraints on the partitioning properties of trace elements in general, and Cu in particular, between vapour and liquid phases evolved from boiling fluids at depth in the Earth's crust. Immiscible liquid and vapour fluid inclusions coexisting in a single quartz grain have been imaged in three dimensions by X-ray Fluorescence Computed Tomography (XFCT). Elemental spatial distributions confirm that Cu, and to a lesser extent As, partition into the vapour phase, whereas Mn, Fe, Zn, Br, Rb, Sr and Pb concentrate in the liquid inclusion. High resolution mapping of the vapour inclusions revealed that Cu is heterogeneously distributed at the scale of a single inclusion and is mostly concentrated as tiny daughter crystals.

  20. 3D imaging of vapour and liquid inclusions from the Mole Granite, Australia, using helical fluorescence tomography

    Science.gov (United States)

    Cauzid, J.; Philippot, P.; Bleuet, P.; Simionovici, A.; Somogyi, A.; Golosio, B.

    2007-08-01

    World class Cu resources are concentrated in porphyry and epithermal ore deposits. Their formation remains partially understood, however, due to a lack of constraints on the partitioning properties of trace elements in general, and Cu in particular, between vapour and liquid phases evolved from boiling fluids at depth in the Earth's crust. Immiscible liquid and vapour fluid inclusions coexisting in a single quartz grain have been imaged in three dimensions by X-ray Fluorescence Computed Tomography (XFCT). Elemental spatial distributions confirm that Cu, and to a lesser extent As, partition into the vapour phase, whereas Mn, Fe, Zn, Br, Rb, Sr and Pb concentrate in the liquid inclusion. High resolution mapping of the vapour inclusions revealed that Cu is heterogeneously distributed at the scale of a single inclusion and is mostly concentrated as tiny daughter crystals.

  1. Absorption by water vapour in the 1 to 2 μm region

    International Nuclear Information System (INIS)

    Smith, K.M.; Ptashnik, I.; Newnham, D.A.; Shine, K.P.

    2004-01-01

    The near-IR (in the range 5000-10 000 cm -1 , 1-2 μm) bands of water vapour have been measured in absorption in the laboratory at sub-Doppler spectral resolution (up to 0.0054 cm -1 after numerical apodisation) by Fourier transform spectroscopy. Measurements have been made at 296 K on pure water vapour (at pressures between 2 and 20 hPa) and mixtures of water and air (at total pressures of 100 and 1000 hPa), at optical path lengths in the range 0.26-9.75 m. Measured absorption intensities have been compared with values calculated using the HITRAN 2000 molecular database. These comparisons indicate that the intensities of the 2ν(1.4 μm) and 2ν+δ(1.14 μm) bands are underestimated in HITRAN 2000 by approximately 15% and 20%, respectively, for pure water vapour measurements, and 12% for both bands in the case of water-air mixtures. The ν+δ (1.86 μm) band is in good agreement (0.4% for pure water vapour and less than 6% for mixtures with air) with HITRAN 2000. For typical atmospheric conditions, these absorption bands are sufficiently strong that radiation is fully absorbed at wavelengths in the region of the band centres. Hence the extra absorption that has been identified has only a modest impact (0.16 W m -2 or about 0.2%) on the global-mean clear-sky absorption of solar radiation. The impact in the upper troposphere is several times larger

  2. Modelling of gas-metal arc welding taking into account metal vapour

    Energy Technology Data Exchange (ETDEWEB)

    Schnick, M; Fuessel, U; Hertel, M; Haessler, M [Institute of Surface and Manufacturing Technology, Technische Universitaet Dresden, D-01062 Dresden (Germany); Spille-Kohoff, A [CFX Berlin Software GmbH, Karl-Marx-Allee 90, 10243 Berlin (Germany); Murphy, A B [CSIRO Materials Science and Engineering, PO Box 218, Lindfield NSW 2070 (Australia)

    2010-11-03

    The most advanced numerical models of gas-metal arc welding (GMAW) neglect vaporization of metal, and assume an argon atmosphere for the arc region, as is also common practice for models of gas-tungsten arc welding (GTAW). These models predict temperatures above 20 000 K and a temperature distribution similar to GTAW arcs. However, spectroscopic temperature measurements in GMAW arcs demonstrate much lower arc temperatures. In contrast to measurements of GTAW arcs, they have shown the presence of a central local minimum of the radial temperature distribution. This paper presents a GMAW model that takes into account metal vapour and that is able to predict the local central minimum in the radial distributions of temperature and electric current density. The influence of different values for the net radiative emission coefficient of iron vapour, which vary by up to a factor of hundred, is examined. It is shown that these net emission coefficients cause differences in the magnitudes, but not in the overall trends, of the radial distribution of temperature and current density. Further, the influence of the metal vaporization rate is investigated. We present evidence that, for higher vaporization rates, the central flow velocity inside the arc is decreased and can even change direction so that it is directed from the workpiece towards the wire, although the outer plasma flow is still directed towards the workpiece. In support of this thesis, we have attempted to reproduce the measurements of Zielinska et al for spray-transfer mode GMAW numerically, and have obtained reasonable agreement.

  3. Effectiveness of Inhaled Loxapine in Dual-Diagnosis Patients: A Case Series.

    Science.gov (United States)

    Roncero, Carlos; Ros-Cucurull, Elena; Grau-López, Lara; Fadeuilhe, Christian; Casas, Miguel

    2016-01-01

    Episodes of psychotic agitation are frequent in patients with dual diagnosis, that is, in patients with concomitant psychiatric and substance use disorders. Rapid intervention is needed to treat the agitation at a mild stage to prevent the escalation to aggressive behavior. Inhaled loxapine has been demonstrated to rapidly improve symptoms of mild-to-moderate agitation in adults with psychiatric disorders (schizophrenia and bipolar disorder), but data on patients with dual diagnosis are scarce. This study is a retrospective review of data from a case series of patients with dual diagnosis, which were attended for symptoms of agitation while at the emergency room (n = 9), in the outpatient clinic (n = 4), or during hospitalization (n = 1) at 1 center in Spain. All patients received inhaled loxapine for treating the agitation episodes. Data from 14 patients with dual diagnosis were reviewed. All patients had 1 or more psychiatric disorders (schizophrenia, bipolar I disorder, drug-induced psychotic disorder, posttraumatic stress, borderline or antisocial personality disorder, depression, or anxiety) along with a variety of substance use disorders (alcohol, cocaine, cannabis, amphetamines, hypnotics and antianxiety drugs, caffeine, or street drugs). Overall, only 1 dose of inhaled loxapine (9.1 mg) was needed to calm each patient during an acute episode of agitation. Inhaled loxapine was rapid, effective, and well accepted in all dual-pathology patients presenting with acute agitation in the emergency setting. Inhaled loxapine facilitated both patient cooperation and an adequate management of his or her disease.

  4. Near-infrared water vapour self-continuum at close to room temperature

    International Nuclear Information System (INIS)

    Ptashnik, I.V.; Petrova, T.M.; Ponomarev, Yu.N.; Shine, K.P.; Solodov, A.A.; Solodov, A.M.

    2013-01-01

    The gaseous absorption of solar radiation within near-infrared atmospheric windows in the Earth's atmosphere is dominated by the water vapour continuum. Recent measurements by Baranov et al. (2011) [17] in 2500 cm −1 (4 μm) window and by Ptashnik et al. (2011) [18] in a few near-infrared windows revealed that the self-continuum absorption is typically an order of magnitude stronger than given by the MT C KD continuum model prior to version 2.5. Most of these measurements, however, were made at elevated temperatures, which makes their application to atmospheric conditions difficult. Here we report new laboratory measurements of the self-continuum absorption at 289 and 318 K in the near-infrared spectral region 1300–8000 cm −1 , using a multipass 30 m base cell with total optical path 612 m. Our results confirm the main conclusions of the previous measurements both within bands and in windows. Of particular note is that we present what we believe to be the first near-room temperature measurement using Fourier Transform Spectrometry of the self-continuum in the 6200 cm −1 (1.6 μm) window, which provides tentative evidence that, at such temperatures, the water vapour continuum absorption may be as strong as it is in 2.1 μm and 4 μm windows and up to 2 orders of magnitude stronger than the MT C KD-2.5 continuum. We note that alternative methods of measuring the continuum in this window have yielded widely differing assessment of its strength, which emphasises the need for further measurements. -- Highlights: ► New lab measurements of the near-infrared water vapour self-continuum absorption. ► First room-temperature data on the self-continuum in the 1.6 μm window. ► In the 1.6 μm window the new data exceed MT C KD-2.5 model by 2 orders of magnitude

  5. Vapour intrusion from the vadose zone—seven algorithms compared

    NARCIS (Netherlands)

    Provoost, J.; Bosman, A.; Reijnders, L.; Bronders, J.; Touchant, K.; Swartjes, F.

    2010-01-01

    Background, aim and scope: Vapours of volatile organic compounds (VOCs) emanating from contaminated soils may move through the unsaturated zone to the subsurface. VOC in the subsurface can be transported to the indoor air by convective air movement through openings in the foundation and basement.

  6. Excess enthalpies and (vapour + liquid) equilibrium data for the binary mixtures of dimethylsulphoxide with ketones

    International Nuclear Information System (INIS)

    Radhamma, M.; Venkatesu, P.; Rao, M.V. Prabhakara; Prasad, D.H.L.

    2007-01-01

    Excess enthalpies (H E ), at ambient pressure and T = 298.15 K, have been measured by using a solution calorimeter for the binary liquid mixtures of dimethyl sulphoxide (DMSO) with ketones, as a function of composition. The ketones chosen in the present investigation were methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), and cyclohexanone (CH). The H E values are positive over the entire composition range for the three binary mixtures. Furthermore, the (vapour + liquid) equilibrium (VLE) was measured at 715 Torr for these mixtures, of different compositions, with the help of Swietoslawski-ebulliometer. The experimental temperature-mole fraction (t-x) data were used to compute Wilson parameters and then used to calculate the equilibrium vapour-phase compositions as well as the theoretical points for these binary mixtures. These Wilson parameters are used to calculate activity coefficients (γ) and these in turn to calculate excess Gibbs free energy (G E ). The intermolecular interactions and structural effects were analyzed on the basis of the measured and derived properties

  7. EVAPORATION: a new vapour pressure estimation methodfor organic molecules including non-additivity and intramolecular interactions

    Directory of Open Access Journals (Sweden)

    S. Compernolle

    2011-09-01

    Full Text Available We present EVAPORATION (Estimation of VApour Pressure of ORganics, Accounting for Temperature, Intramolecular, and Non-additivity effects, a method to predict (subcooled liquid pure compound vapour pressure p0 of organic molecules that requires only molecular structure as input. The method is applicable to zero-, mono- and polyfunctional molecules. A simple formula to describe log10p0(T is employed, that takes into account both a wide temperature dependence and the non-additivity of functional groups. In order to match the recent data on functionalised diacids an empirical modification to the method was introduced. Contributions due to carbon skeleton, functional groups, and intramolecular interaction between groups are included. Molecules typically originating from oxidation of biogenic molecules are within the scope of this method: aldehydes, ketones, alcohols, ethers, esters, nitrates, acids, peroxides, hydroperoxides, peroxy acyl nitrates and peracids. Therefore the method is especially suited to describe compounds forming secondary organic aerosol (SOA.

  8. Electrostatics in pharmaceutical aerosols for inhalation.

    Science.gov (United States)

    Wong, Jennifer; Chan, Hak-Kim; Kwok, Philip Chi Lip

    2013-08-01

    Electrostatics continues to play an important role in pharmaceutical aerosols for inhalation. Despite its ubiquitous nature, the charging process is complex and not well understood. Nonetheless, significant advances in the past few years continue to improve understanding and lead to better control of electrostatics. The purpose of this critical review is to present an overview of the literature, with an emphasis on how electrostatic charge can be useful in improving pulmonary drug delivery.

  9. Lung dosimetry for inhaled radon progeny

    International Nuclear Information System (INIS)

    Hofmann, W.

    1986-01-01

    Lung cancer risk assessment for inhaled radon progeny requires a detailed knowledge of the dose distribution pattern throughout the human respiratory tract. Current lung dosimetry models take into acocunt aerosol deposition in a formalized airway structrue, modification of the initial deposition pattern by clearance mechanisms, and the energy deposited by alpha particles in sensitive cells of the bronchial epithelium. The resulting dose distribution pattern depends on the characteristics of the inhaled aerosol and the breathing pattern. Special emphasis has been laid on the age dependency of the anatomical structure of the human lung and the resulting doses, as well as on the rediological significance of enhanced aerosol deposition at bronchial bifuraction. The biological variability inherent in all morphometric, physiological and histological parameters involved in lung dosimetry suggests the application of stochastic modelling techniques. Examples for the use of Monte Carlo methods presented here are the random walk of inhaled particles through a random airway geometry, and the influence of the intra-subject variability of radiation doses on radiation protection standards. At the cellular level the concept of absorbed dose loses its significance and has to be replaced by microdosimetric concepts, such as internal microdosimtry or track structure theory. An image-analysis model allows us to construct specific energy distributions in sensitive lung cells. Application of a track structure model of alpha particle interaction with bronchial epithelial cells permits the calculation of probabilities for inactivation, transformation, and tumor induction. The latter has been used to analyse lung cancer risk at low doses in Chinese high background areas

  10. Effect of slow-solvent-vapour treatment on performance of polymer photovoltaic devices

    International Nuclear Information System (INIS)

    Zhi-Hui, Feng; Yan-Bing, Hou; Quan-Min, Shi; Xiao-Jun, Liu; Feng, Teng

    2010-01-01

    In this work, enhanced poly(3-hexylthiophene):[6,6]-phenyl-C61-butyric acid methyl ester (P3HT:PCBM) bulkheterojunction photovoltaic devices are achieved via slow-solvent-vapour treatment. The correlations between the morphology of the active layer and the photovoltaic performance of polymer-based solar cell are investigated. The active layers are characterized by atomic force microscopy and optical absorption. The results show that slow-solvent-vapour treatment can induce P3HT self-organization into an ordered structure, leading to the enhanced absorption and efficient charge transport. (cross-disciplinary physics and related areas of science and technology)

  11. Dose-effect studies with inhaled plutonium in beagles

    International Nuclear Information System (INIS)

    Anon.

    1982-01-01

    Data are presented for all dogs employed in current life-span dose effect studies with inhaled 239 PuO 2 , and 239 Pu nitrate. Information is presented on the estimated initial alveolar deposition, based on external thorax counts and on estimated lung weights at time of exposure. Information is also provided on the current interpretation of the most prominent clinical-pathological features associated with the death of animals

  12. A whiff of death: fatal volatile solvent inhalation abuse.

    Science.gov (United States)

    Steffee, C H; Davis, G J; Nicol, K K

    1996-09-01

    Inhalation abuse of volatile solvents, previously known generically as "glue sniffing," is typically pursued by adolescents. A wide range of legal, easily obtained products containing volatile substances are available for abuse. We report two illustrative cases of fatal volatile substance abuse: gasoline sniffing in a 20-year-old man and aerosol propellant gas inhalation (aerosol air freshener) in a 16-year-old girl with underlying reactive airway disease. Although the ratio of deaths to nonfatal inhalation escapades is extremely low, volatile solvent abuse carries the risk of sudden death due to cardiac arrest after a dysrhythmia or vasovagal event, central nervous system respiratory depression, hypoxia and hypercapnia due to the techniques of inhalation, and other mechanisms. Investigation of the patient's substance abuse history, examination of the scene of death, and special toxicologic analyses are critical to identifying volatile substance inhalation abuse as the cause of death because anatomic autopsy findings will typically be nonspecific. Above all, physicians must suspect the diagnosis of volatile substance inhalation abuse, especially in any case of sudden death involving an otherwise healthy young person.

  13. Hydrogen production with fully integrated fuel cycle gas and vapour core reactors

    International Nuclear Information System (INIS)

    Anghaie, S.; Smith, B.

    2004-01-01

    This paper presents results of a conceptual design study involving gas and vapour core reactors (G/VCR) with a combined scheme to generate hydrogen and power. The hydrogen production schemes include high temperature electrolysis as well as two dominant thermochemical hydrogen production processes. Thermochemical hydrogen production processes considered in this study included the calcium-bromine process and the sulphur-iodine processes. G/VCR systems are externally reflected and moderated nuclear energy systems fuelled by stable uranium compounds in gaseous or vapour phase that are usually operated at temperatures above 1500 K. A gas core reactor with a condensable fuel such as uranium tetrafluoride (UF 4 ) or a mixture of UF 4 and other metallic fluorides (BeF 2 , LiF, KF, etc.) is commonly known as a vapour core reactor (VCR). The single most relevant and unique feature of gas/vapour core reactors is that the functions of fuel and coolant are combined into one. The reactor outlet temperature is not constrained by solid fuel-cladding temperature limits. The maximum fuel/working fluid temperature in G/VCR is only constrained by the reactor vessel material limits, which is far less restrictive than the fuel clad. Therefore, G/VCRs can potentially provide the highest reactor and cycle temperature among all existing or proposed fission reactor designs. Gas and vapour fuel reactors feature very low fuel inventory and fully integrated fuel cycle that provide for exceptional sustainability and safety characteristics. With respect to fuel utilisation, there is no fuel burn-up limit for gas core reactors due to continuous recycling of the fuel. Owing to the flexibility in nuclear design characteristics of cavity reactors, a wide range of conversion ratio from completely burner to breeder is achievable. The continuous recycling of fuel in G/VCR systems allow for complete burning of actinides without removing and reprocessing of the fuel. The only waste products at the back

  14. Prediction of acute inhalation toxicity using in vitro lung surfactant inhibition

    DEFF Research Database (Denmark)

    Sørli, Jorid Birkelund; Huang, Yishi; Da Silva, Emilie

    2018-01-01

    impregnation products using the constant flow through set-up of the constrained drop surfactometer to determine if they inhibited LS function or not. The same products were tested in a mouse inhalation bioassay to determine their toxicity in vivo. The sensitivity was 100%, i.e. the in vitro method predicted...... the chemical composition of the products and induction of toxicity. The currently accepted method for determination of acute inhalation toxicity is based on experiments on animals; it is time-consuming, expensive and causes stress for the animals. Impregnation products are present on the market in large...... numbers and amounts and exhibit great variety. Therefore, an alternative method to screen for acute inhalation toxicity is needed. The aim of our study was to determine if inhibition of lung surfactant by impregnation products in vitro could accurately predict toxicity in vivo in mice. We tested 21...

  15. A method of estimating inspiratory flow rate and volume from an inhaler using acoustic measurements

    International Nuclear Information System (INIS)

    Holmes, Martin S; D'Arcy, Shona; O'Brien, Ultan; Reilly, Richard B; Seheult, Jansen N; Geraghty, Colm; Costello, Richard W; Crispino O'Connell, Gloria

    2013-01-01

    Inhalers are devices employed to deliver medication to the airways in the treatment of respiratory diseases such as asthma and chronic obstructive pulmonary disease. A dry powder inhaler (DPI) is a breath actuated inhaler that delivers medication in dry powder form. When used correctly, DPIs improve patients' clinical outcomes. However, some patients are unable to reach the peak inspiratory flow rate (PIFR) necessary to fully extract the medication. Presently clinicians have no reliable method of objectively measuring PIFR in inhalers. In this study, we propose a novel method of estimating PIFR and also the inspiratory capacity (IC) of patients' inhalations from a commonly used DPI, using acoustic measurements. With a recording device, the acoustic signal of 15 healthy subjects using a DPI over a range of varying PIFR and IC values was obtained. Temporal and spectral signal analysis revealed that the inhalation signal contains sufficient information that can be employed to estimate PIFR and IC. It was found that the average power (P ave ) in the frequency band 300–600 Hz had the strongest correlation with PIFR (R 2 = 0.9079), while the power in the same frequency band was also highly correlated with IC (R 2 = 0.9245). This study has several clinical implications as it demonstrates the feasibility of using acoustics to objectively monitor inhaler use. (paper)

  16. Diagnostic Utility of Total IgE in Foods, Inhalant, and Multiple Allergies in Saudi Arabia.

    Science.gov (United States)

    Al-Mughales, Jamil A

    2016-01-01

    Objective. To assess the diagnostic significance of total IgE in foods, inhalant, and multiple allergies. Methods. Retrospective review of the laboratory records of patients who presented with clinical suspicion of food or inhalant allergy between January 2013 and December 2014. Total IgE level was defined as positive for a value >195 kU/L; and diagnosis was confirmed by the detection of specific IgE (golden standard) for at least one food or inhalant allergen and at least two allergens in multiple allergies. Results. A total of 1893 (male ratio = 0.68, mean age = 39.0 ± 19.2 years) patients were included. Total IgE had comparable sensitivity (55.8% versus 59.6%) and specificity (83.9% versus 84.4%) in food versus inhalant allergy, respectively, but a superior PPV in inhalant allergy (79.1% versus 54.4%). ROC curve analysis showed a better diagnostic value in inhalant allergies (AUC = 0.817 (95% CI = 0.796-0.837) versus 0.770 (95% CI = 0.707-0.833)). In multiple allergies, total IgE had a relatively good sensitivity (78.6%), while negative IgE testing (allergies with 91.5% certitude. Conclusion. Total IgE assay is not efficient as a diagnostic test for foods, inhalant, or multiple allergies. The best strategy should refer to specific IgE testing guided by a comprehensive atopic history.

  17. Inhaler technique maintenance: gaining an understanding from the patient's perspective.

    Science.gov (United States)

    Ovchinikova, Ludmila; Smith, Lorraine; Bosnic-Anticevich, Sinthia

    2011-08-01

    The aim of this study was to determine the patient-, education-, and device-related factors that predict inhaler technique maintenance. Thirty-one community pharmacists were trained to deliver inhaler technique education to people with asthma. Pharmacists evaluated (based on published checklists), and where appropriate, delivered inhaler technique education to patients (participants) in the community pharmacy at baseline (Visit 1) and 1 month later (Visit 2). Data were collected on participant demographics, asthma history, current asthma control, history of inhaler technique education, and a range of psychosocial aspects of disease management (including adherence to medication, motivation for correct technique, beliefs regarding the importance of maintaining correct technique, and necessity and concern beliefs regarding preventer therapy). Stepwise backward logistic regression was used to identify the predictors of inhaler technique maintenance at 1 month. In total 145 and 127 participants completed Visits 1 and 2, respectively. At baseline, 17% of patients (n = 24) demonstrated correct technique (score 11/11) which increased to 100% (n = 139) after remedial education by pharmacists. At follow-up, 61% (n = 77) of patients demonstrated correct technique. The predictors of inhaler technique maintenance based on the logistic regression model (X(2) (3, N = 125) = 16.22, p = .001) were use of a dry powder inhaler over a pressurized metered-dose inhaler (OR 2.6), having better asthma control at baseline (OR 2.3), and being more motivated to practice correct inhaler technique (OR 1.2). Contrary to what is typically recommended in previous research, correct inhaler technique maintenance may involve more than repetition of instructions. This study found that past technique education factors had no bearing on technique maintenance, whereas patient psychosocial factors (motivation) did.

  18. Inhaled antibiotics in non-cystic fibrosis bronchiectasis: A meta-analysis.

    Science.gov (United States)

    Xu, Li; Zhang, Fei; Du, Shuai; Yu, Qi; Chen, Lin; Long, Li-Hui; Li, Ya-Ming; Jia, Ai-Hua

    2016-09-01

    To evaluate the efficacy and safety of inhaled antibiotics for the treatment of non-cystic fibrosis bronchiectasis (NCFB). Pubmed, Cochrane library, Embase, Elsevier, OVID, Springerlink, Web of knowledge and NEJM were searched for randomized controlled trials (RCTs) on inhaled antibiotics in treatment of NCFB from inception until April 2015. Meta-analysis was conducted to assess the efficacy and safety of inhaled antibiotics in the treatment of NCFB. Twelve RCTs involving 1154 participants were included. They showed that inhaled antibiotics were more effective in reduction of sputum bacterial density, eradication of P. aeruginosa, prolonged time to exacerbation and reduction of new pathogens emergence with no significant difference in adverse events compared with control groups. However, we did not find significant benefits of inhaled antibiotics in reducing the risk of acute exacerbation, improving health-related quality of life and reduction of P. aeruginosa resistance. Moreover, inhaled antibiotics exerted a statistically significant reduction in FEV1%. Inhaled antibiotics may be an alternative pathway to inhibit airway inflammation with no more adverse events in patients with NCFB.

  19. Oxidation of volatile organic vapours in air by solid potassium permanganate.

    Science.gov (United States)

    Mahmoodlu, Mojtaba Ghareh; Hartog, Niels; Majid Hassanizadeh, S; Raoof, Amir

    2013-06-01

    Volatile organic compounds (VOCs) may frequently contaminate groundwater and pose threat to human health when migrating into the unsaturated soil zone and upward to the indoor air. The kinetic of chemical oxidation has been investigated widely for dissolved VOCs in the saturated zone. But, so far there have been few studies on the use of in situ chemical oxidation (ISCO) of vapour phase contaminants. In this study, batch experiments were carried out to evaluate the oxidation of trichloroethylene (TCE), ethanol, and toluene vapours by solid potassium permanganate. Results revealed that solid potassium permanganate is able to transform the vapour of these compounds into harmless oxidation products. The degradation rates for TCE and ethanol were higher than for toluene. The degradation process was modelled using a kinetic model, linear in the gas concentration of VOC [ML(-3)] and relative surface area of potassium permanganate grains (surface area of potassium permanganate divided by gas volume) [L(-1)]. The second-order reaction rate constants for TCE, ethanol, and toluene were found to be equal to 2.0×10(-6) cm s(-1), 1.7×10(-7) cm s(-1), and 7.0×10(-8) cm s(-1), respectively. Copyright © 2013 Elsevier Ltd. All rights reserved.

  20. Oscillatory vapour shielding of liquid metal walls in nuclear fusion devices.

    Science.gov (United States)

    van Eden, G G; Kvon, V; van de Sanden, M C M; Morgan, T W

    2017-08-04

    Providing an efficacious plasma facing surface between the extreme plasma heat exhaust and the structural materials of nuclear fusion devices is a major challenge on the road to electricity production by fusion power plants. The performance of solid plasma facing surfaces may become critically reduced over time due to progressing damage accumulation. Liquid metals, however, are now gaining interest in solving the challenge of extreme heat flux hitting the reactor walls. A key advantage of liquid metals is the use of vapour shielding to reduce the plasma exhaust. Here we demonstrate that this phenomenon is oscillatory by nature. The dynamics of a Sn vapour cloud are investigated by exposing liquid Sn targets to H and He plasmas at heat fluxes greater than 5 MW m -2 . The observations indicate the presence of a dynamic equilibrium between the plasma and liquid target ruled by recombinatory processes in the plasma, leading to an approximately stable surface temperature.Vapour shielding is one of the interesting mechanisms for reducing the heat load to plasma facing components in fusion reactors. Here the authors report on the observation of a dynamic equilibrium between the plasma and the divertor liquid Sn surface leading to an overall stable surface temperature.

  1. Characteristics of patients making serious inhaler errors with a dry powder inhaler and association with asthma-related events in a primary care setting

    Science.gov (United States)

    Westerik, Janine A. M.; Carter, Victoria; Chrystyn, Henry; Burden, Anne; Thompson, Samantha L.; Ryan, Dermot; Gruffydd-Jones, Kevin; Haughney, John; Roche, Nicolas; Lavorini, Federico; Papi, Alberto; Infantino, Antonio; Roman-Rodriguez, Miguel; Bosnic-Anticevich, Sinthia; Lisspers, Karin; Ställberg, Björn; Henrichsen, Svein Høegh; van der Molen, Thys; Hutton, Catherine; Price, David B.

    2016-01-01

    Abstract Objective: Correct inhaler technique is central to effective delivery of asthma therapy. The study aim was to identify factors associated with serious inhaler technique errors and their prevalence among primary care patients with asthma using the Diskus dry powder inhaler (DPI). Methods: This was a historical, multinational, cross-sectional study (2011–2013) using the iHARP database, an international initiative that includes patient- and healthcare provider-reported questionnaires from eight countries. Patients with asthma were observed for serious inhaler errors by trained healthcare providers as predefined by the iHARP steering committee. Multivariable logistic regression, stepwise reduced, was used to identify clinical characteristics and asthma-related outcomes associated with ≥1 serious errors. Results: Of 3681 patients with asthma, 623 (17%) were using a Diskus (mean [SD] age, 51 [14]; 61% women). A total of 341 (55%) patients made ≥1 serious errors. The most common errors were the failure to exhale before inhalation, insufficient breath-hold at the end of inhalation, and inhalation that was not forceful from the start. Factors significantly associated with ≥1 serious errors included asthma-related hospitalization the previous year (odds ratio [OR] 2.07; 95% confidence interval [CI], 1.26–3.40); obesity (OR 1.75; 1.17–2.63); poor asthma control the previous 4 weeks (OR 1.57; 1.04–2.36); female sex (OR 1.51; 1.08–2.10); and no inhaler technique review during the previous year (OR 1.45; 1.04–2.02). Conclusions: Patients with evidence of poor asthma control should be targeted for a review of their inhaler technique even when using a device thought to have a low error rate. PMID:26810934

  2. Vapour phase synthesis of salol over solid acids via transesterification

    Indian Academy of Sciences (India)

    Administrator

    rate of reactants, WHSV and time-on-stream on the conversion (%) of phenol and selectivity (%) of salol ... Possible reaction mechanisms for the formation of salol and diphenyl ether over ... Hence, vapour-phase conditions of the experiment.

  3. Spiromax, a New Dry Powder Inhaler: Dose Consistency under Simulated Real-World Conditions.

    Science.gov (United States)

    Canonica, Giorgio Walter; Arp, Jan; Keegstra, Johan René; Chrystyn, Henry

    2015-10-01

    Spiromax(®) is a novel dry powder inhaler for patients with asthma or chronic obstructive pulmonary disease (COPD). The studies presented here provide further data on attributes (in vitro dosing consistency with budesonide-formoterol (DuoResp) Spiromax; flow rates through empty versions of the Spiromax and Turbuhaler inhaler) of importance to patients with asthma or COPD. Dose-delivery studies were performed using low-, middle-, and high-strength DuoResp Spiromax. Dose consistency was assessed over inhaler life. Total emitted doses (TEDs) were measured at various flow rates, after exposure to high and low temperature or humidity, at different inhaler orientations, and after dropping the inhaler. The criterion for evaluating dose uniformity was whether mean TEDs were within the product specification limits. In separate studies, flow rates were measured after training, using the patient information leaflets, and again after enhanced training as part of a randomized, open-label, cross-over study. Mean values for both budesonide and formoterol were within 85%-115% of the label claim for each strength of DuoResp Spiromax for initial dose uniformity and for the other investigated conditions (temperature, humidity, orientation, dropping, knocking), with the exception of approximately an 80% increase in first dose after dropping the inhaler (subsequent doses not affected). In the flow rate patient study, two patients' inhalations with Spiromax and six with Turbuhaler were 60 L/min. DuoResp Spiromax consistently meets dose uniformity criteria, under controlled laboratory conditions and with variations intended to mimic real-world use. Following enhanced training, all patients in the flow study were able to achieve the minimal inspiratory flow rate of >30 L/min, which is required for effective treatment.

  4. Vapour-liquid equilibria of the hard core Yukawa fluid

    NARCIS (Netherlands)

    Smit, B.; Frenkel, D.

    1991-01-01

    Techniques which extend the range of applicability of the Gibbs ensemble technique for particles which interact with a hard core potential are described. The power of the new technique is demonstrated in a numerical study of the vapour-liquid coexistence curve of the hard core Yukawa fluid.

  5. Clinical effectiveness of the Respimat® inhaler device in managing chronic obstructive pulmonary disease: evidence when compared with other handheld inhaler devices

    Directory of Open Access Journals (Sweden)

    et al

    2011-02-01

    Full Text Available Felix SF Ram1, Celso R Carvallho2, John White31School of Health and Social Services, Massey University, Auckland, New Zealand; 2Department of Physical Therapy, School of Medicine, University of São Paulo, Brazil; 3York Hospitals NHS Foundation Trust, York Hospital, York, UKObjectives: Medication for the management of chronic obstructive pulmonary disease (COPD may be delivered by a number of different inhaler devices. This study was undertaken to determine the clinical effectiveness of the Respimat® handheld inhaler device compared with other handheld inhaler devices for the delivery of medication in stable COPD.Methodology: A systematic review of high-quality randomized controlled clinical trials comparing Respimat with other inhaler devices using the same medication was performed. Studies were searched for in the Cochrane Central Register of Controlled Trials as well as other relevant electronic databases. Manufacturers of inhaled COPD medication were also contacted for potential trials.Results: Seven studies of high methodological quality with 3813 participants were included in the review. Three trials used Handihaler® as the comparator inhaler, three used a chlorofluorocarbon metered-dose inhaler (CFC-MDI, and one trial used a hydroflouroalkane (HFA-MDI. When Respimat was compared with Handihaler, the following reported outcomes were not significantly different: trough forced expiratory volume in 1 second (FEV1 (weighted mean difference [WMD] 0.01 L; P = 0.14, trough forced vital capacity (FVC (WMD 0.001 L: P = 0.88, peak FEV1 (WMD 0.01 L: P = 0.08, peak FVC (WMD 0.01 L: P = 0.55, morning peak expiratory flow rate (PEFR (WMD 5.06 L/min: P = 0.08, and evening PEFR (WMD 4.39 L/min: P = 0.15. Furthermore, there were no differences when Respimat was compared with Handihaler for risk of exacerbations (relative risk [RR] 0.94: P = 0.81, dry mouth (RR 1.57: P = 0.34, or nasopharyngitis (RR 1.42: P = 0.22. For Respimat compared with CFC-MDI, the

  6. Inhaling habits among smokers of different types of cigarette

    Energy Technology Data Exchange (ETDEWEB)

    Wald, N.J.; Idle, M.; Boreham, J.; Bailey, A.

    1980-12-01

    Inhaling habits were studied in 1316 men who freely smoked their usual brands of cigarette. An index of inhaling was calculated for each person by dividing the estimated increase in carboxyhaemoglobin level from a standard number of cigarettes by the carbon monoxide yield of the cigarette smoked. Smokers of ventilated filter cigarettes inhaled 82% more than smokers of plain cigarettes (p less than 0.001) and those who smoked unventilated filter cigarettes inhaled 36% more (p less than 0.001). Cigarette consumption was similar among smokers of each type of cigarette. Assuming that the intake of tar and nicotine is proportional to the inhaling index, the intake in either group of filter cigarette smokers would have been less than that in plain cigarette smokers. Among smokers of unventilated cigarettes, however, the intake would not have been much less.

  7. Opportunities for inhaler device selection in elderly patients with asthma or COPD

    Directory of Open Access Journals (Sweden)

    Barrons R

    2015-12-01

    Full Text Available Robert Barrons,1 James Wheeler,2 J Andrew Woods1 1Wingate University School of Pharmacy, Wingate, NC, USA; 2University of Tennessee Health Science Center, Nashville, TN, USA Abstract: An anticipated surge in the elderly population will be accompanied by a rise in aging patients with asthma or COPD. Clinician selection of inhalers needs to address the unique challenges to elderly patients. These challenges to the use of inhalers include diminished physical and cognitive abilities, as well as cost reimbursement issues associated with polypharmacy and the Medicare gap. Clinicians should consider patient preferences for an inhaler device that provides ease of administration, and addresses conveniences such as portability, visual, and auditory indicators of dosing completion. The addition of spacer devices resolves hand-breath coordination difficulty with pressurized metered dose inhalers, but reduces overall inhaler convenience. Soft mist inhalers (Respimat® improve ease of administration, but use may be limited by cost and formulary availability. Multiple dose dry powder inhalers provide convenience and simplified use by requiring only one to two steps prior to administration, but concerns of peak inspiratory flow requirements remain among patients with advanced age and severity of COPD. If unaddressed, these challenges to inhaler selection contribute to inappropriate use of inhalers in 41% to 69% of patients, accompanied by at least 51% non-adherence to treatment. Clinicians must first avail themselves of reputable educational resources regarding new inhaler developments and administration, for competent patient instruction. Patient education should include a checklist of inhaler technique, with physical demonstration of each device by the patient and provider. Device demonstration significantly improves inhaler technique and identifies the need for nebulization therapy. Clinician and patient knowledge of available inhalers and their

  8. Vapour pressure of caesium over nuclear graphite

    International Nuclear Information System (INIS)

    Faircloth, R.L.; Pummery, F.C.W.

    1976-01-01

    The vapour pressure of caesium over a fine-grained isotropic moulded gilsocarbon nuclear graphite intended for use in the manufacture of fuel tubes for the high temperature reactor has been determined as a function of temperature and concentration by means of the Knudsen effusion technique. The concentration range 0 to 10 μg caesium/g graphite was investigated and it was concluded that a Langmuir adsorption situation exists under these conditions. (author)

  9. Inhalation of uranium ores

    International Nuclear Information System (INIS)

    Stuart, B.O.; Jackson, P.O.

    1975-01-01

    In previous studies the biological dispositions of individual long-lived alpha members of the uranium chain ( 238 U, 234 U and 230 Th) were determined during and following repeated inhalation exposures of rats to pitchblende (26 percent U 3 O 8 ) ore. Although finely dispersed ore in secular equilibrium was inhaled, 230 Th/ 234 U radioactivity ratios in the lungs rose from 1.0 to 2.5 during 8 weeks of exposures and increased to 9.2 by four months after cessation of exposures. Marked non-equilibrium levels were also found in the tracheobronchial lymph nodes, kidneys, liver, and femur. Daily exposures of beagle dogs to high levels of this ore for 8 days resulted in lung 230 Th/ 234 U ratios of >2.0. Daily exposures of dogs to lower levels (0.1 mg/1) for 6 months, with sacrifice 15 months later, resulted in lung and thoracic lymph node 230 Th/ 234 U ratios ranging from 3.6 to 9 and nearly 7, respectively. The lungs of hamsters exposed to carnotite (4 percent U 3 O 8 ) ore in current lifespan studies show 230 Th/ 234 U ratios as high as 2.0 during daily inhalation of this ore in secular equilibrium. Beagle dogs sacrificed after several years of daily inhalations of the same carnotite ore plus radon daughters also showed marked non-equilibrium ratios of 230 Th/ 234 U, ranging from 5.6 to 7.4 in lungs and 6.2 to 9.1 in thoracic lymph nodes. This pattern of higher retention of 230 Th than 234 U in lungs, thoracic lymph nodes, and other tissues is thus consistent for two types of uranium ore among several species and suggests a reevaluation of maximum permissible air concentrations of ore, currently based only on uranium content

  10. Toxicity of inhaled Ca-DTPA in the beagle dog

    International Nuclear Information System (INIS)

    Smith, V.H.; Ragan, H.A.; Lund, J.E.; Hackett, P.L.

    1975-01-01

    There are several advantages to the administration of Ca- DTPA by inhalation rather than intravenous drip for the decorporation of certain radionuclides. Among these are the possibility of treating very promptly following an accidental incorporation to achieve maximum treatment effectiveness and convenince for medical management, even to the extent that treatment can be self-administered. The present investigational New Drug permit allows treatment of humans only by the intravenous route and animal studies are required to justify the new route. Earlier work in rats and hamsters showed five successive daily inhalations of Ca-DTPA aerosols (dose 1 to 4 times human i.v. dose) produced a transitory emphysema in 17/40 rats serially sacrificed up to 3 weeks following the last exposure and in 10/20 hamsters up to 1 week after exposure. No emphysema was seen in rats sacrificed after 3 weeks and in hamsters after 1 week following the exposures. Results of tests in dogs administered DTPA by inhalation showed hyperplasia of the gastric submucosal lymphoid follicles observed 1 week following the last exposure may be treatment-related, but other observed changes were considered unrelated. (U.S.)

  11. SiC fibre by chemical vapour deposition on tungsten filament

    Indian Academy of Sciences (India)

    Unknown

    SiC fibre by chemical vapour deposition on tungsten filament ... CMCs), in defence and industrial applications. SiC has attractive ... porosity along with chemical purity. This is lacking .... reactor. Since mercury is very toxic it should be removed.

  12. Particle-induced pulmonary acute phase response may be the causal link between particle inhalation and cardiovascular disease

    DEFF Research Database (Denmark)

    Saber, Anne T.; Jacobsen, Nicklas R.; Jackson, Petra

    2014-01-01

    Inhalation of ambient and workplace particulate air pollution is associated with increased risk of cardiovascular disease. One proposed mechanism for this association is that pulmonary inflammation induces a hepatic acute phase response, which increases risk of cardiovascular disease. Induction...... epidemiological studies. In this review, we present and review emerging evidence that inhalation of particles (e.g., air diesel exhaust particles and nanoparticles) induces a pulmonary acute phase response, and propose that this induction constitutes the causal link between particle inhalation and risk...

  13. Inhalant abuse of computer cleaner manifested as angioedema.

    Science.gov (United States)

    Kurniali, Peter C; Henry, Letitia; Kurl, Rita; Meharg, Joseph V

    2012-01-01

    Inhalant abuse is the intentional inhalation of chemical vapors or volatile substance to achieve a euphoric effect. Although no statistical data are reported yet, inhalant abuse is potentially life-threatening and has resulted in a wide range of toxic effects such as central nervous system depression, seizures, aspiration, cardiac arrhythmia, asphyxiation, hypoxia, metabolic acidosis, and sudden death among others. We are reporting a 25-year-old white man who was brought to the emergency department after inhaling aerosolized computer-cleaning spray composed of difluoroethane. He was found to have marked upper and lower lip facial swelling consistent with angioedema. The patient also had a prolonged QT interval, mild inspiratory stridor, but no urticaria. In this case, we believe the difluoroethane-related angioedema represents either idiopathic or bradykinin-induced angioedema.

  14. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1987-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in predicting health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; lymphopenia and neutropenia occurred at the two highest dose levels. They have also observed radiation pneumonitis, lung cancer, and bone cancer at the three highest dose levels. 1 figure, 3 tables

  15. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1986-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in predicting health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; lymphopenia and neutropenia occurred at the two highest dose levels. The authors have also observed radiation pneumonitis, lung cancer, and bone cancer at the three highest dose levels. 1 figure, 4 tables

  16. Inhaled plutonium nitrate in dogs

    International Nuclear Information System (INIS)

    Dagle, G.E.

    1982-01-01

    The major objective of this project is to determine dose-effect relationships of inhaled plutonium nitrate in dogs to aid in the prediction of health effects of accidental exposure in man. For lifespan dose-effect studies, beagle dogs were given a single inhalation exposure to 239 Pu(NO 3 ) 4 , in 1976 and 1977. The earliest biological effect was on the hematopoietic system; as described in previous Annual Reports, lymphopenia and neutropenia occurred at the two highest dose levels. Radiation pneumonitis, lung cancer, and bone cancer have been observed at the highest dose levels

  17. Retrieval of total water vapour in the Arctic using microwave humidity sounders

    Science.gov (United States)

    Cristian Scarlat, Raul; Melsheimer, Christian; Heygster, Georg

    2018-04-01

    Quantitative retrievals of atmospheric water vapour in the Arctic present numerous challenges because of the particular climate characteristics of this area. Here, we attempt to build upon the work of Melsheimer and Heygster (2008) to retrieve total atmospheric water vapour (TWV) in the Arctic from satellite microwave radiometers. While the above-mentioned algorithm deals primarily with the ice-covered central Arctic, with this work we aim to extend the coverage to partially ice-covered and ice-free areas. By using modelled values for the microwave emissivity of the ice-free sea surface, we develop two sub-algorithms using different sets of channels that deal solely with open-ocean areas. The new algorithm extends the spatial coverage of the retrieval throughout the year but especially in the warmer months when higher TWV values are frequent. The high TWV measurements over both sea-ice and open-water surfaces are, however, connected to larger uncertainties as the retrieval values are close to the instrument saturation limits.This approach allows us to apply the algorithm to regions where previously no data were available and ensures a more consistent physical analysis of the satellite measurements by taking into account the contribution of the surface emissivity to the measured signal.

  18. Calculation of vapour pressures over mixed carbide fuels

    International Nuclear Information System (INIS)

    Joseph, M.; Mathews, C.K.

    1988-01-01

    Vapour pressure over the uranium-plutonium mixed carbide (Usub(l-p) Pusub(p C) was calculated in the temperature range of 1300-9000 for various compositions (p=0.1 to 0.7). Effects of variation of the sesquicarbide content were also studied. The principle of corresponding states was applied to UC and mixed carbides to obtain the equation of state. (author)

  19. Vapour loss (``boiling'') as a mechanism for fluid evolution in metamorphic rocks

    Science.gov (United States)

    Trommsdorff, Volkmar; Skippen, George

    1986-11-01

    The calculation of fluid evolution paths during reaction progress is considered for multicomponent systems and the results applied to the ternary system, CO2-H2O-NaCl. Fluid evolution paths are considered for systems in which a CO2-rich phase of lesser density (vapour) is preferentially removed from the system leaving behind a saline aqueous phase (liquid). Such “boiling” leads to enrichment of the residual aqueous phase in dissolved components and, for certain reaction stoichiometries, to eventual saturation of the fluids in salt components. Distinctive textures, particularly radiating growths of prismatic minerals such as tremolite or diopside, are associated with saline fluid inclusions and solid syngenetic salt inclusions at a number of field localities. The most thoroughly studied of these localities is Campolungo, Switzerland, where metasomatic rocks have developed in association with fractures and veins at 500° C and 2,000 bars of pressure. The petrography of these rocks suggests that fluid phase separation into liquid and vapour has been an important process during metasomatism. Fracture systems with fluids at pressure less than lithostatic may facilitate the loss of the less dense vapour phase to conditions of the amphibolite facies.

  20. Development, production, and application of sealed-off copper and gold vapour lasers

    International Nuclear Information System (INIS)

    Lyabin, Nikolai A; Chursin, A D; Ugol'nikov, S A; Koroleva, M E; Kazaryan, M A

    2001-01-01

    An analysis is made of the current state of the art of scientific and engineering advances in the field of repetitively pulsed self-heating metal vapour (copper and gold) lasers based on industrial, sealed-off, high-temperature, metalceramic and metal-glass active elements. The major applications of these lasers are discussed. The energy, spatial, and time characteristics of the lasers and their dependence on the parameters and construction of the laser active elements (tubes) and optical resonators are considered. The ways for the development of new high-power industrial laser active elements with a high efficiency (1 - 2%) and a service life of 500 - 1000 h are analysed. An average output power of 80 W was realised with a laser tube 150 cm in length and 32 mm in diameter. When the pumping efficiency is improved by raising the voltage to 30 - 35 kV, this system in a copper vapour laser will allow an output power of 100 W to be obtained with one active element. The characteristics of industrial versions of metal vapour lasers manufactured in different countries are compared and discussed. (invited paper)

  1. A comparison of different spray chemical vapour deposition methods for the production of undoped ZnO thin films

    International Nuclear Information System (INIS)

    Garnier, Jerome; Bouteville, Anne; Hamilton, Jeff; Pemble, Martyn E.; Povey, Ian M.

    2009-01-01

    Two different methods of spray chemical vapour deposition have been used to grow ZnO thin films on glass substrates from zinc acetate solution over the temperature range 400 o C to 550 o C. The first of these is named InfraRed Assisted Spray Chemical Vapour Deposition (IRAS-CVD). This method uses intense IR radiation to heat not only the substrate but also the gaseous species entering the reactor. The second method is a more conventional approach known simply as ultrasonic spray CVD, which utilises IR lamps to heat the substrate only. By way of comparing these two approaches we present data obtained from contact angle measurements, crystallinity and mean crystallite size, photoluminescence, electrical and optical properties. Additionally we have examined the role of annealing within the IRAS-CVD reactor environment.

  2. Phyto-inhalation for treatment of complications of acute respiratory viral diseases

    Directory of Open Access Journals (Sweden)

    I.B. Ershova

    2017-03-01

    Full Text Available Inhalations (inhalation of medicinal substances are one of the effective ways to treat upper respiratory tract diseases and colds. Inhalation therapy is used to treat rhinitis, sinusitis, tonsillitis, pharyngitis, laryngitis, bronchitis and pneumonia, which can be complications of acute respiratory viral infections. The main rules of inhalation are as follows to conduct the procedure better after 1.5 hours after eating; clothes should not impede breathing; the procedure can be carried out only while sitting or standing; solution for the inhaler for treatment of bronchitis should be fresh; it is necessary to strictly keep the prescribed dosage; the time of the procedure should also be respected — usually it is from 1 to 4 minutes, sometimes for adults up to 10 minutes, for children the inhalation period is shorter — 1–2 minutes. Contraindications to inhalation are body temperature above 37.5 degrees; propensity to nasal blee­ding in a patient; propensity to increased arterial pressure, with cardiovascular failure; purulent inflammation of the tonsils; respiratory failure. The procedure should be stopped immediately in case of appearance of adverse symptoms such as shortness of breath, dizziness, difficulty in breathing. Therefore, inhalations must be prescribed by a doctor after examination of a patient. During inhalations in rhinitis, you should try to inhale the vapor through the nose. For effective treatment of rhinitis, inhalations from conife­rous plants are very suitable: fir, pine, juniper, larch, from steamed dried chamomile flowers, mint, and blackberry leaves. Honey inhalations can be used for the treatment of acute and chronic diseases of the upper respiratory tract (tonsillitis, pharyngitis, laryngitis and tracheitis. Medical herbal inhalation for children should be carried out from the age of two years. This must be done under the constant supervision of an adult. Leaves of coniferous trees: pine, fir, if or juniper, cedar

  3. Range-energy relations and stopping power of water, water vapour and tissue equivalent liquid for α particles over the energy range 0.5 to 8 MeV

    International Nuclear Information System (INIS)

    Palmer, R.B.J.; Akhavan-Rezayat, Ahmad

    1978-01-01

    Experimental range-energy relations are presented for alpha particles in water, water vapour and tissue equivalent liquid at energies up to 8 MeV. From these relations differential stopping powers are derived at 0.25 MeV energy intervals. Consideration is given to sources of error in the range-energy measurements and to the uncertainties that these will introduce into the stopping power values. The ratio of the differential stopping power of muscle equivalent liquid to that of water over the energy range 0.5 to 7.5 MeV is discussed in relation to the specific gravity and chemical composition of the muscle equivalent liquid. Theoretical molecular stopping power calculations based upon the Bethe formula are also presented for water. The effect of phase upon the stopping power of water is discussed. The molecular stopping power of water vapour is shown to be significantly higher than that of water for energies below 1.25 MeV and above 2.5 MeV, the ratio of the two stopping powers rising to 1.39 at 0.5 MeV and to 1.13 at 7.0 MeV. Stopping power measurements for other liquids and vapours are compared with the results for water and water vapour and some are observed to have stopping power ratios in the vapour and liquid phases which vary with energy in a similar way to water. It is suggested that there may be several factors contributing to the increased stopping power of liquids. The need for further experimental results on a wider range of liquids is stressed

  4. Knowledge of spacer device, peak flow meter and inhaler technique ...

    African Journals Online (AJOL)

    Background: Metered dose inhalers are cornerstone in effective management of bronchial asthma when correctly used. Most studies hitherto have focused on assessing patient's knowledge of inhaler technique. We sought to assess the knowledge of inhaler technique, spacer device and peak flow meter among doctors and ...

  5. Comparison of Hexane Vapour Permeation in Two Different Polymeric Membranes via an Innovative In-line FID Detection Method

    Directory of Open Access Journals (Sweden)

    Z. Petrusová

    2017-07-01

    Full Text Available This manuscript presents a novel method for the analysis of vapour permeation through polymeric membranes based on in-line analysis of the permeate with an FID detector. The hexane vapour permeation was studied for two commercially available membranes, namely low-density polyethylene (LDPE and thin-film-composite polyamide (PA membrane. The hexane permeation was studied at temperatures of 25–45 °C, hexane vapour activity in the range of 0.2–0.8 and trans-membrane pressures of 5–50 kPa. Two fundamentally different membranes were chosen to demonstrate the potential and sensitivity of the permeation apparatus. Upon increasing the temperature from 25 to 45 °C, the flux in LDPE was found to increase almost fourfold over the whole activity range. The nonlinear increase of the flux with activity indicates plasticization of the polymer by hexane. Contrarily, the flux in the PA membrane increases almost linearly with activity, with only a minor upward curvature. Since the PA is far away from any phase transition, it is less temperature-dependent than LDPE. The activation energy for permeation demonstrates that the temperature dependence in the LDPE membrane is dominated by changes in diffusion, whereas it is dominated by changes in solubility in the PA membrane.

  6. Carbon dioxide and water vapour characteristics on the west coast ...

    Indian Academy of Sciences (India)

    Carbon dioxide, water vapour, air temperature and wind measurements at 10 Hz sampling rate were carried out over the ... seasonal and annual variations in the CO2 bal- ance. Hence, it is .... motion below produced by shear stress near the.

  7. The impact of water vapour on climate

    International Nuclear Information System (INIS)

    Zittel, W.; Altmann, M.

    1994-01-01

    Do water vapour emissions from a solar hydrogen system affect the climate? This question was investigated by the authors. They state: The comparison with natural emissions by evaporation shows that emissions caused by energy generation, regardless of whether they stem from fossil, nuclear or regenerative energy systems, are negligible with a proportion of 0.005%. On the other hand, carbon dioxide emissions with a proportion of 4%, constitute a factor which already impedes the natural cycle. (orig.) [de

  8. Chemical vapour deposition of thin-film dielectrics

    International Nuclear Information System (INIS)

    Vasilev, Vladislav Yu; Repinsky, Sergei M

    2005-01-01

    Data on the chemical vapour deposition of thin-film dielectrics based on silicon nitride, silicon oxynitride and silicon dioxide and on phosphorus- and boron-containing silicate glasses are generalised. The equipment and layer deposition procedures are described. Attention is focussed on the analysis and discussion of the deposition kinetics and on the kinetic models for film growth. The film growth processes are characterised and data on the key physicochemical properties of thin-film covalent dielectric materials are given.

  9. Inhaled plutonium oxide in dogs

    International Nuclear Information System (INIS)

    Park, J.F.

    1985-01-01

    This project is concerned with long-term experiments to determine the lifespan dose-effect relationships of inhaled 239 PuO 2 and 238 PuO 2 in beagles. The data will be used to estimate the health effects of inhaled transuranics. Beagle dogs given a single exposure to 239 PuO 2 or 238 PuO 2 aerosols to obtain graded levels of initial lung burdens are being observed for lifespan dose-effect relationships. Mortality due to radiation pneumonitis and lung tumor increased in the four highest dose-level groups exposed to 239 PuO 2 , during the 13-yr postexposure period. During the 10 1/2 years after exposure to 238 PuO 2 , mortality due to lung and/or bone tumors increased in the three highest dose-level groups. Chronic lymphopenia, occurring 0.5 to 2 year after exposure, was the earliest observed effect after inhalation of either 239 PuO 2 or 238 PuO 2 in the four highest dose-level groups that had initial lung burdens greater than or equal to 80 nCi. 3 figures, 6 tables

  10. Terbutaline accumulates in blood and urine following daily therapeutic inhalation

    DEFF Research Database (Denmark)

    Krogh, Nanna; Rzeppa, Sebastian; Dyreborg, Anders

    2017-01-01

    ×d) of inhaled terbutaline. After inhalation of terbutaline at each trial, subjects performed 90 min of bike ergometer exercise at 65% of maximal oxygen consumption after which they stayed inactive. Blood and urine samples were collected before and after inhalation of terbutaline. Samples were analyzed by high...

  11. Effect of inhaled formoterol and budesonide on exacerbations of asthma

    NARCIS (Netherlands)

    Pauwels, RA; Lofdahl, CG; Postma, DS; Tattersfield, AE; OByrne, P; Barnes, PJ; Ullman, A

    1997-01-01

    Background The role of long-acting, inhaled beta(2)-agonists in treating asthma is uncertain. In a double-blind study, we evaluated the effects of adding inhaled formoterol to both lower and higher doses of the inhaled glucocorticoid budesonide. Methods After a four-week run-in period of treatment

  12. Treatment of proctalgia fugax with salbutamol inhalation.

    Science.gov (United States)

    Eckardt, V F; Dodt, O; Kanzler, G; Bernhard, G

    1996-04-01

    Although no generally effective treatment for proctalgia fugax is known, inhalation of salbutamol has been reported to shorten pain attacks in isolated cases. We conducted a randomized, double-blind, placebo-controlled, crossover trial of inhaled salbutamol in 18 patients with proctalgia fugax. The clinical effect was evaluated by recording the duration of severe pain and discomfort during acute attacks. In addition, anorectal motility recordings were analyzed for possible changes in anal resting tone, sphincter relaxation during rectal distension and in rectal compliance prior to and following administration of the two test substances. Sixteen patients completed all investigations. Compared to placebo, salbutamol inhalation shortened the duration of severe pain (p = 0.019). The effect was most marked in patients having prolonged attacks. In the asymptomatic state, neither salbutamol nor placebo led to a significant change in anal resting pressure, anal relaxation during rectal distension, or rectal compliance. Salbutamol also did not alter the threshold for rectal sensation. Salbutamol inhalation shortens attacks of severe pain in patients with proctalgia fugax. The mechanism of this effect remains unexplained.

  13. Inhaled corticosteroid metered-dose inhalers: how do variations in technique for solutions versus suspensions affect drug distribution?

    Science.gov (United States)

    Robinson, Christie A; Tsourounis, Candy

    2013-03-01

    To assess the literature that evaluates how variations in metered-dose inhaler (MDI) technique affect lung distribution for inhaled corticosteroids (ICSs) formulated as MDI suspensions and solutions. PubMed (up to November 2012) and Cochrane Library (up to November 2012) were searched using the terms metered-dose inhalers, HFA 134a, Asthma/*drug therapy, and inhaled corticosteroids. In addition, reference citations from publications identified were reviewed. All articles in English from the data sources that assessed MDI technique comparing total lung distribution (TLD) of MDI solutions or suspensions formulated with ICSs were included in the review. Five relevant studies were identified. Five controlled studies compared how variations in MDI technique affect TLD for ICS MDI solutions with suspensions. MDI solutions resulted in greater TLD compared with larger particle MDI suspensions. Delayed or early inspiration upon device actuation of MDI solutions resulted in less TLD than coordinated actuation, but with a 3- to 4-times greater TLD than MDI suspensions inhaled using a standard technique. A sixth study evaluated inspiratory flow rates (IFR) for small, medium, and large particles. Rapid and slow IFRs resulted in similar TLD for small particles, while far fewer particles reached the airways with medium and large particles at rapid, rather than slow, IFRs. Based on the literature evaluated, standard MDI technique should be used for ICS suspensions. ICS MDI solutions can provide a higher average TLD than larger-particle ICS suspensions using standard technique, discoordinated inspiration and medication actuation timing, or rapid and slow IFRs. ICS MDI solutions allow for a more forgiving technique, which makes them uniquely suitable options for patients with asthma who have difficultly with MDI technique.

  14. Inhalation Exposure Input Parameters for the Biosphere Model

    Energy Technology Data Exchange (ETDEWEB)

    K. Rautenstrauch

    2004-09-10

    This analysis is one of 10 reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN) biosphere model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. Inhalation Exposure Input Parameters for the Biosphere Model is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling, and the plan for development of the biosphere abstraction products for TSPA, as identified in the Technical Work Plan for Biosphere Modeling and Expert Support (BSC 2004 [DIRS 169573]). This analysis report defines and justifies values of mass loading for the biosphere model. Mass loading is the total mass concentration of resuspended particles (e.g., dust, ash) in a volume of air. Mass loading values are used in the air submodel of ERMYN to calculate concentrations of radionuclides in air inhaled by a receptor and concentrations in air surrounding crops. Concentrations in air to which the receptor is exposed are then used in the inhalation submodel to calculate the dose contribution to the receptor from inhalation of contaminated airborne particles. Concentrations in air surrounding plants are used in the plant submodel to calculate the concentrations of radionuclides in foodstuffs contributed from uptake by foliar interception.

  15. Inhalation Exposure Input Parameters for the Biosphere Model

    International Nuclear Information System (INIS)

    K. Rautenstrauch

    2004-01-01

    This analysis is one of 10 reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN) biosphere model. The ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. Inhalation Exposure Input Parameters for the Biosphere Model is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the ERMYN is presented in Figure 1-1. This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling, and the plan for development of the biosphere abstraction products for TSPA, as identified in the Technical Work Plan for Biosphere Modeling and Expert Support (BSC 2004 [DIRS 169573]). This analysis report defines and justifies values of mass loading for the biosphere model. Mass loading is the total mass concentration of resuspended particles (e.g., dust, ash) in a volume of air. Mass loading values are used in the air submodel of ERMYN to calculate concentrations of radionuclides in air inhaled by a receptor and concentrations in air surrounding crops. Concentrations in air to which the receptor is exposed are then used in the inhalation submodel to calculate the dose contribution to the receptor from inhalation of contaminated airborne particles. Concentrations in air surrounding plants are used in the plant submodel to calculate the concentrations of radionuclides in foodstuffs contributed from uptake by foliar interception

  16. Inhalation Exposure Input Parameters for the Biosphere Model

    Energy Technology Data Exchange (ETDEWEB)

    M. Wasiolek

    2006-06-05

    This analysis is one of the technical reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), referred to in this report as the biosphere model. ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. ''Inhalation Exposure Input Parameters for the Biosphere Model'' is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the biosphere model is presented in Figure 1-1 (based on BSC 2006 [DIRS 176938]). This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and how this analysis report contributes to biosphere modeling. This analysis report defines and justifies values of atmospheric mass loading for the biosphere model. Mass loading is the total mass concentration of resuspended particles (e.g., dust, ash) in a volume of air. Mass loading values are used in the air submodel of the biosphere model to calculate concentrations of radionuclides in air inhaled by a receptor and concentrations in air surrounding crops. Concentrations in air to which the receptor is exposed are then used in the inhalation submodel to calculate the dose contribution to the receptor from inhalation of contaminated airborne particles. Concentrations in air surrounding plants are used in the plant submodel to calculate the concentrations of radionuclides in foodstuffs contributed from uptake by foliar interception. This

  17. Inhalation Exposure Input Parameters for the Biosphere Model

    International Nuclear Information System (INIS)

    M. Wasiolek

    2006-01-01

    This analysis is one of the technical reports that support the Environmental Radiation Model for Yucca Mountain, Nevada (ERMYN), referred to in this report as the biosphere model. ''Biosphere Model Report'' (BSC 2004 [DIRS 169460]) describes in detail the conceptual model as well as the mathematical model and its input parameters. This report documents development of input parameters for the biosphere model that are related to atmospheric mass loading and supports the use of the model to develop biosphere dose conversion factors (BDCFs). The biosphere model is one of a series of process models supporting the total system performance assessment (TSPA) for a Yucca Mountain repository. ''Inhalation Exposure Input Parameters for the Biosphere Model'' is one of five reports that develop input parameters for the biosphere model. A graphical representation of the documentation hierarchy for the biosphere model is presented in Figure 1-1 (based on BSC 2006 [DIRS 176938]). This figure shows the interrelationships among the products (i.e., analysis and model reports) developed for biosphere modeling and how this analysis report contributes to biosphere modeling. This analysis report defines and justifies values of atmospheric mass loading for the biosphere model. Mass loading is the total mass concentration of resuspended particles (e.g., dust, ash) in a volume of air. Mass loading values are used in the air submodel of the biosphere model to calculate concentrations of radionuclides in air inhaled by a receptor and concentrations in air surrounding crops. Concentrations in air to which the receptor is exposed are then used in the inhalation submodel to calculate the dose contribution to the receptor from inhalation of contaminated airborne particles. Concentrations in air surrounding plants are used in the plant submodel to calculate the concentrations of radionuclides in foodstuffs contributed from uptake by foliar interception. This report is concerned primarily with the

  18. Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications

    Science.gov (United States)

    Behara, Srinivas R.B.; Farkas, Dale R.; Hindle, Michael; Longest, P. Worth

    2013-01-01

    Purpose The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. Methods DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. Results The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. Conclusions High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD 90%, and ED > 80%. PMID:23949304

  19. Development of a high efficiency dry powder inhaler: effects of capsule chamber design and inhaler surface modifications.

    Science.gov (United States)

    Behara, Srinivas R B; Farkas, Dale R; Hindle, Michael; Longest, P Worth

    2014-02-01

    The objective of this study was to explore the performance of a high efficiency dry powder inhaler (DPI) intended for excipient enhanced growth (EEG) aerosol delivery based on changes to the capsule orientation and surface modifications of the capsule and device. DPIs were constructed by combining newly designed capsule chambers (CC) with a previously developed three-dimensional (3D) rod array for particle deagglomeration and a previously optimized EEG formulation. The new CCs oriented the capsule perpendicular to the incoming airflow and were analyzed for different air inlets at a constant pressure drop across the device. Modifications to the inhaler and capsule surfaces included use of metal dispersion rods and surface coatings. Aerosolization performance of the new DPIs was evaluated and compared with commercial devices. The proposed capsule orientation and motion pattern increased capsule vibrational frequency and reduced the aerosol MMAD compared with commercial/modified DPIs. The use of metal rods in the 3D array further improved inhaler performance. Coating the inhaler and capsule with PTFE significantly increased emitted dose (ED) from the optimized DPI. High efficiency performance is achieved for EEG delivery with the optimized DPI device and formulation combination producing an aerosol with MMAD  90%, and ED > 80%.

  20. Which inhaled corticosteroid and long-acting β-agonist combination is better in patients with moderate-to-severe asthma, a dry powder inhaler or a pressurized metered-dose inhaler?

    Science.gov (United States)

    Muraki, Masato; Gose, Kyuya; Hanada, Soichiro; Sawaguchi, Hirochiyo; Tohda, Yuji

    2017-11-01

    Two main types of devices are used to facilitate the administration of inhaled corticosteroid (ICS) and long-acting β-agonist (LABA) in combination, dry powder inhalers (DPIs) and pressurized metered-dose inhalers (pMDIs). There are few reports comparing the effects of the two devices, and it is unknown which should be recommended for asthma patients with given sets of characteristics. In the current study, the beneficial effects and side effects associated with DPIs and pMDIs were compared, and the question of which device should be recommended for asthma patients was investigated. A prospective, randomized, crossover, comparative study in adult outpatients with asthma was conducted using salmeterol/fluticasone propionate combination (SFC) 50 μg/250 μg, one inhalation of Adoair ® 250 Diskus ® twice daily or two inhalations of Adoair ® 125 Aerosol twice daily, for 8 weeks. Questionnaires, exhaled nitric oxide (FeNO) tests and pulmonary function tests were administered after the use of each device for 8 weeks, and the results derived from each device were compared. Sixty-eight subjects were included in the final analysis. There were no significant differences between quality-of-life scores, FeNO, spirometry test results and forced oscillation results. With regard to patient preferences, 57.4% preferred the Adoair ® Aerosol and 35.3% preferred the Adoair ® Diskus ® , as determined via the comparative evaluation questionnaire. Although DPI prescription accounts for the predominant market share of combined ICS/LABA in Japan, patients preferred a pMDI device to a DPI device. Compared to DPIs, pMDIs may be the preferential choice for patients with asthma.

  1. Response of water vapour D-excess to land-atmosphere interactions in a semi-arid environment

    KAUST Repository

    Parkes, Stephen

    2016-06-30

    The stable isotopic composition of water vapour provides information about moisture sources and processes difficult to obtain with traditional measurement techniques. Recently, it has been proposed that the D-excess of water vapour can provide a diagnostic tracer of continental moisture recycling. However, D-excess exhibits a diurnal cycle that has been observed across a variety of ecosystems and may be influenced by a range of processes beyond regional-scale moisture recycling, including local evaporation (ET) fluxes. There is a lack of measurements of D-excess in evaporation (ET) fluxes, which has made it difficult to assess how ET fluxes modify the Dexcess in water vapour (dv). With this in mind, we employed a chamber-based approach to directly measure D-excess in ET (dET) fluxes. We show that ET fluxes imposed a negative forcing on the ambient vapour and could not explain the higher daytime dv values. The low dET observed here was sourced from a soil water pool that had undergone an extended drying period, leading to low D-excess in the soil moisture pool. A strong correlation between daytime dv and locally measured relative humidity was consistent with an oceanic moisture source, suggesting that remote hydrological processes were the major contributor to daytime dv variability. During the early evening, ET fluxes into a shallow nocturnal inversion layer caused a lowering of dv values near the surface. In addition, transient mixing of vapour with a higher D-excess from above the nocturnal inversion modified these values, causing large variability during the night. These results indicate dET can generally be expected to show

  2. Inhaled therapy for the management of perioperative pulmonary hypertension

    Directory of Open Access Journals (Sweden)

    C A Thunberg

    2015-01-01

    Full Text Available Patients with pulmonary hypertension (PH are at high risk for complications in the perioperative setting and often receive vasodilators to control elevated pulmonary artery pressure (PAP. Administration of vasodilators via inhalation is an effective strategy for reducing PAP while avoiding systemic side effects, chiefly hypotension. The prototypical inhaled pulmonary-specific vasodilator, nitric oxide (NO, has a proven track record but is expensive and cumbersome to implement. Alternatives to NO, including prostanoids (such as epoprostenol, iloprost, and treprostinil, NO-donating drugs (sodium nitroprusside, nitroglycerin, and nitrite, and phosphodiesterase inhibitors (milrinone, sildenafil may be given via inhalation for the purpose of treating elevated PAP. This review will focus on the perioperative therapy of PH using inhaled vasodilators.

  3. ‘Great ease and simplicity of action’: Dr Nelson’s Inhaler and the origins of modern inhalation therapy

    Directory of Open Access Journals (Sweden)

    Barry Murnane

    2017-11-01

    Full Text Available Unveiled at the conclusion of a meeting of the Royal Medical and Chirurgical Society in 1861,[1] ‘Dr Nelson’s Improved Inhaler’ was one of the most important milestones in the genesis of reliable treatment of respiratory ailments in the modern era. Affordable and suitable for self-medication, the Dr Nelson’s Inhaler offered simple and reliable relief for patients with respiratory and pulmonary ailments. Conspicuous for its modesty and simplicity, it was one of the most widely produced, reproduced, and used inhalation devices in the final third of the nineteenth century. By reconstructing the ‘biography’ of the Nelson Inhaler, this article will attempt to sketch a network of medical and commercial interests and expertise in London which aligned in the 1860s to help establish inhalation as a popular, inexpensive, and trusted form of medical therapy for pulmonary ailments. This article will look at what connects physicians, apothecaries, and patients in the era: the medicines and technologies that were prescribed, made, bought, and which caused wellness, side-effects, and even death. This approach allows us to develop a narrative of respiratory illness as it was experienced by practitioners and patients alike.

  4. Ethanol vapour sensing properties of screen printed WO3 thick films

    Indian Academy of Sciences (India)

    TECS

    trations. The WO3 thick films exhibit excellent ethanol vapour sensing properties with a maximum sensitivity ... methanol, acetone, isopropanol and acetic acid, have been reported .... maximum sensitivity was obtained at an operating tem-.

  5. Asthma control in patients receiving inhaled corticosteroid and long-acting beta2-agonist fixed combinations. A real-life study comparing dry powder inhalers and a pressurized metered dose inhaler extrafine formulation

    Directory of Open Access Journals (Sweden)

    Nicolini Gabriele

    2011-07-01

    Full Text Available Abstract Background Although patients have more problems using metered dose inhalers, clinical comparisons suggest they provide similar control to dry powder inhalers. Using real-life situations this study was designed to evaluate asthma control in outpatients with moderate to severe persistent asthma and to compare efficacy of fixed combinations of inhaled corticosteroids (ICS and long acting beta-agonists (LABA. Methods This real-life study had a cross-sectional design. Patients using fixed combinations of ICS and LABA had their asthma control and spirometry assessed during regular visits. Results 111 patients were analyzed: 53 (47.7% received maintenance therapy of extrafine beclomethasone-formoterol (BDP/F pressurized metered dose inhaler (pMDI, 25 (22.5% fluticasone-salmeterol (FP/S dry powder inhaler (DPI, and 33 (29.7% budesonide-formoterol (BUD/F DPI. Severity of asthma at time of diagnosis, assessed by the treating physician, was comparable among groups. Asthma control was achieved by 45.9% of patients; 38.7% were partially controlled and 15.3% were uncontrolled. In the extrafine BDF/F group, asthma control total score, daytime symptom score and rescue medication use score were significantly better than those using fixed DPI combinations (5.8 ± 6.2 vs. 8.5 ± 6.8; 1.4 ± 1.8 vs. 2.3 ± 2.1; 1.8 ± 2.2 vs. 2.6 ± 2.2; p = 0.0160; p = 0.012 and p = 0.025, respectively and the mean daily ICS dose were significantly lower. Conclusions pMDI extrafine BDP/F combination demonstrated better asthma control compared to DPIs formulated with larger particles. This could be due to the improved lung deposition of the dose or less reliance on the optimal inhalation technique or both.

  6. Inhaled Loxapine for Agitation in Intoxicated Patients: A Case Series.

    Science.gov (United States)

    Roncero, Carlos; Ros-Cucurull, Elena; Palma-Álvarez, Raúl Felipe; Abad, Alfonso Carlos; Fadeuilhe, Christian; Casas, Miquel; Grau-López, Lara

    Episodes of agitation are frequent in intoxicated patients who have a substance use disorder, a psychiatric disorder or both (dual diagnosis). For managing the agitation, it is necessary to act promptly in a safe environment and addressing any underlying etiology. Inhaled loxapine improves symptoms of agitation in adults with psychiatric disorders (eg, schizophrenia) within 10 minutes of administration. Recently, some reports have documented the usefulness of loxapine in dual diagnoses patients with agitation. However, the efficacy of loxapine in intoxicated patients has not been deeply addressed. This report describes a case series of 12 patients (with addiction or dual disorder) who received inhaled loxapine for symptoms of psychomotor agitation during intoxication with different substances (eg, alcohol, cannabis, or cocaine) at 1 center in Spain. Data from 12 patients were reviewed, 5 patients were attended at the emergency room, 4 at the addiction and dual diagnosis unit, and 3 were treated during hospitalization for detoxification. All patients were under effects of substances. They had substance use disorder (including cannabis, cocaine, alcohol, hypnotics, and hallucinogens), and almost all (90%) presented 1 or more psychiatric disorders. One dose of inhaled loxapine was effective in 9 patients (75%), and in 3 patients, a second dose was required. Only mild dizziness was reported in 1 patient after the second dose. The acute agitation was effectively and quickly managed with inhaled loxapine in all intoxicated patients and enabled the appropriate clinical evaluation of the agitated state and the patient's management.

  7. Practice makes perfect: self-reported adherence a positive marker of inhaler technique maintenance.

    Science.gov (United States)

    Azzi, Elizabeth; Srour, Pamela; Armour, Carol; Rand, Cynthia; Bosnic-Anticevich, Sinthia

    2017-04-24

    Poor inhaler technique and non-adherence to treatment are major problems in the management of asthma. Patients can be taught how to achieve good inhaler technique, however maintenance remains problematic, with 50% of patients unable to demonstrate correct technique. The aim of this study was to determine the clinical, patient-related and/or device-related factors that predict inhaler technique maintenance. Data from a quality-controlled longitudinal community care dataset was utilized. 238 patients using preventer medications where included. Data consisted of patient demographics, clinical data, medication-related factors and patient-reported outcomes. Mixed effects logistic regression was used to identify predictors of inhaler technique maintenance at 1 month. The variables found to be independently associated with inhaler technique maintenance using logistic regression (Χ 2 (3,n = 238) = 33.24, p < 0.000) were inhaler technique at Visit 1 (OR 7.1), device type (metered dose inhaler and dry powder inhalers) (OR 2.2) and self-reported adherent behavior in the prior 7 days (OR 1.3). This research is the first to unequivocally establish a predictive relationship between inhaler technique maintenance and actual patient adherence, reinforcing the notion that inhaler technique maintenance is more than just a physical skill. Inhaler technique maintenance has an underlying behavioral component, which future studies need to investigate. BEHAVIORAL ELEMENT TO CORRECT LONG-TERM INHALER TECHNIQUES: Patients who consciously make an effort to perfect asthma inhaler technique will maintain their skills long-term. Elizabeth Azzi at the University of Sydney, Australia, and co-workers further add evidence that there is a strong behavioral component to patients retaining correct inhaler technique over time. Poor inhaler technique can limit asthma control, affecting quality of life and increasing the chances of severe exacerbations. Azzi's team followed 238 patients to

  8. Quintupling Inhaled Glucocorticoids to Prevent Childhood Asthma Exacerbations.

    Science.gov (United States)

    Jackson, Daniel J; Bacharier, Leonard B; Mauger, David T; Boehmer, Susan; Beigelman, Avraham; Chmiel, James F; Fitzpatrick, Anne M; Gaffin, Jonathan M; Morgan, Wayne J; Peters, Stephen P; Phipatanakul, Wanda; Sheehan, William J; Cabana, Michael D; Holguin, Fernando; Martinez, Fernando D; Pongracic, Jacqueline A; Baxi, Sachin N; Benson, Mindy; Blake, Kathryn; Covar, Ronina; Gentile, Deborah A; Israel, Elliot; Krishnan, Jerry A; Kumar, Harsha V; Lang, Jason E; Lazarus, Stephen C; Lima, John J; Long, Dayna; Ly, Ngoc; Marbin, Jyothi; Moy, James N; Myers, Ross E; Olin, J Tod; Raissy, Hengameh H; Robison, Rachel G; Ross, Kristie; Sorkness, Christine A; Lemanske, Robert F

    2018-03-08

    Asthma exacerbations occur frequently despite the regular use of asthma-controller therapies, such as inhaled glucocorticoids. Clinicians commonly increase the doses of inhaled glucocorticoids at early signs of loss of asthma control. However, data on the safety and efficacy of this strategy in children are limited. We studied 254 children, 5 to 11 years of age, who had mild-to-moderate persistent asthma and had had at least one asthma exacerbation treated with systemic glucocorticoids in the previous year. Children were treated for 48 weeks with maintenance low-dose inhaled glucocorticoids (fluticasone propionate at a dose of 44 μg per inhalation, two inhalations twice daily) and were randomly assigned to either continue the same dose (low-dose group) or use a quintupled dose (high-dose group; fluticasone at a dose of 220 μg per inhalation, two inhalations twice daily) for 7 days at the early signs of loss of asthma control ("yellow zone"). Treatment was provided in a double-blind fashion. The primary outcome was the rate of severe asthma exacerbations treated with systemic glucocorticoids. The rate of severe asthma exacerbations treated with systemic glucocorticoids did not differ significantly between groups (0.48 exacerbations per year in the high-dose group and 0.37 exacerbations per year in the low-dose group; relative rate, 1.3; 95% confidence interval, 0.8 to 2.1; P=0.30). The time to the first exacerbation, the rate of treatment failure, symptom scores, and albuterol use during yellow-zone episodes did not differ significantly between groups. The total glucocorticoid exposure was 16% higher in the high-dose group than in the low-dose group. The difference in linear growth between the high-dose group and the low-dose group was -0.23 cm per year (P=0.06). In children with mild-to-moderate persistent asthma treated with daily inhaled glucocorticoids, quintupling the dose at the early signs of loss of asthma control did not reduce the rate of severe asthma

  9. The vapour pressures over saturated aqueous solutions of sodium and potassium acetates, chlorates, and perchlorates

    Energy Technology Data Exchange (ETDEWEB)

    Apelblat, Alexander [Department of Chemical Engineering, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel)]. E-mail: apelblat@bgu.ac.il; Manzurola, Emanuel [Department of Chemical Engineering, Ben Gurion University of the Negev, Beer Sheva 84105 (Israel)

    2007-08-15

    Vapour pressures of water over saturated solutions of sodium acetate, potassium acetate, sodium perchlorate, and potassium perchlorate were determined over the (278 to 318) K temperature range and compared with available in the literature data. The cases of saturated solutions of sodium chlorate and potassium chlorate are also considered. The determined vapour pressures were used to obtain the water activities, the osmotic coefficients, and the molar enthalpies of vaporization in considered systems.

  10. Thermogravimetric studies of vapour-aerosol interactions

    International Nuclear Information System (INIS)

    Henshaw, J.; Newland, M.S.; Wood, S.J.

    1991-01-01

    Thermogravimetric analysis has been used to study the interaction of iodine vapour with cadmium, silver and manganese monoxide substrates. These studies have demonstrated the importance of time-dependence data on reaction rates. Iodine did not react with manganese monoxide (as expected from thermodynamic considerations); however, extensive reaction did occur with silver and cadmium. Two rate limiting mechanisms were observed: mass transfer of iodine molecules from the gas phase (leading to linear reaction rates) and parabolic kinetics (ie inversely proportional to the extent of reaction) when the rate was limited by a diffusion process through the reaction product. (author)

  11. Inhaled Antibiotics in the Treatment of Nosocomial Pneumonia

    Directory of Open Access Journals (Sweden)

    A. N. Kuzovlev

    2013-01-01

    Full Text Available Nosocomial pneumonia is the most common nosocomial infection in intensive care units. Rational antibiotic therapy is the basis for the treatment of nosocomial pneumonia. There is currently a challenge of the pathogens of nosocomial pneumonia being resistant to most of the antibiotics recommended for its treatment. Inhaled antibiotics used in combination with systemic drugs are an effective and safe treatment for nosocomial pneumonia. This review of literature characterizes the current possibilities of inhaled antibiotic therapy for nosocomial pneumonia in detail and describes medicaments and the advantages and disadvantages of this treatment option. Despite insufficient evidence in circumstances where the microorganisms are polyresistant and where the design of novel antibiotics shows no promise, the use of inhaled antibiotics is an important alternative in the treatment of severe nosocomial pneumonia caused by polyresistant gram-negative bacteria. Key words: nosocomial pneumonia, antibiotic therapy, inhaled antibiotics, resistance.

  12. Modification of Peng Robinson EOS for modelling (vapour + liquid) equilibria with electrolyte solutions

    International Nuclear Information System (INIS)

    Baseri, Hadi; Lotfollahi, Mohammad Nader

    2011-01-01

    Highlights: → Extended PR-EOS was presented for VLE of H 2 O/Salt/CO 2 systems at high pressure. → The proposed EPR-EOS is based upon contributions to the Helmholtz energy. → Born, Margules, and Debye-Huckel or mean spherical approximation terms were used. → Two different mixing rules Panagiotopoulos and Reid and Kwak and Mansoori (KM) were used. → A combination of KM mixing rule with DH term results more accurate VLE results. - Abstract: A modification of the extended Peng-Robinson equation of state (PR-EOS) is presented to describe the (vapour + liquid) equilibria of systems containing water and salts. The modification employs three additional terms including a Born term, a Margules term and two terms separately used for estimation of the long-range electrostatic interactions (the Debye-Huckel (DH) or the mean spherical approximation (MSA) terms). Effects of two mixing rules, first, the Panagiotopoulos and Reid mixing rule (PR) and, second, the Kwak and Mansoori mixing rule (KM), on the final values of VLE calculations are also investigated. The results show that the KM mixing rule is more appropriate than the PR mixing rule. The proposed equation of state is used to calculate the (vapour + liquid) equilibrium (VLE) of the systems containing (water + sodium sulphate + carbon dioxide) and (water + sodium chloride + carbon dioxide) at high pressure. The comparison of calculated results with the experimental data shows that a combination of KM mixing rule with the DH term results a more accurate VLE values.

  13. Pharmacokinetics and Bioavailability of Inhaled Esketamine in Healthy Volunteers.

    Science.gov (United States)

    Jonkman, Kelly; Duma, Andreas; Olofsen, Erik; Henthorn, Thomas; van Velzen, Monique; Mooren, René; Siebers, Liesbeth; van den Beukel, Jojanneke; Aarts, Leon; Niesters, Marieke; Dahan, Albert

    2017-10-01

    Esketamine is traditionally administered via intravenous or intramuscular routes. In this study we developed a pharmacokinetic model of inhalation of nebulized esketamine with special emphasis on pulmonary absorption and bioavailability. Three increasing doses of inhaled esketamine (dose escalation from 25 to 100 mg) were applied followed by a single intravenous dose (20 mg) in 19 healthy volunteers using a nebulizer system and arterial concentrations of esketamine and esnorketamine were obtained. A multicompartmental pharmacokinetic model was developed using population nonlinear mixed-effects analyses. The pharmacokinetic model consisted of three esketamine, two esnorketamine disposition and three metabolism compartments. The inhalation data were best described by adding two absorption pathways, an immediate and a slower pathway, with rate constant 0.05 ± 0.01 min (median ± SE of the estimate). The amount of esketamine inhaled was reduced due to dose-independent and dose-dependent reduced bioavailability. The former was 70% ± 5%, and the latter was described by a sigmoid EMAX model characterized by the plasma concentration at which absorption was impaired by 50% (406 ± 46 ng/ml). Over the concentration range tested, up to 50% of inhaled esketamine is lost due to the reduced dose-independent and dose-dependent bioavailability. We successfully modeled the inhalation of nebulized esketamine in healthy volunteers. Nebulized esketamine is inhaled with a substantial reduction in bioavailability. Although the reduction in dose-independent bioavailability is best explained by retention of drug and particle exhalation, the reduction in dose-dependent bioavailability is probably due to sedation-related loss of drug into the air.

  14. Inhaled Surfactant Therapy in Newborns in Artificial Lung Ventilation

    Directory of Open Access Journals (Sweden)

    S. A. Perepelitsa

    2014-01-01

    Full Text Available Objective: to evaluate the efficiency of inhaled surfactant therapy in neonatal infants with respiratory failure.Subjects and methods. The trial enrolled 13 premature neonatal infants; their mean gestational age was 31.8±2.8 weeks and the birth weight was 1825±600.9 g. They had a oneminute Apgar score of 4.3±1.4. All the neonates needed mechanical ventilation (MV atbirth because the leading clinical sign was respiratory failure caused by acute intranatal hypoxia, neonatal amniotic fluid aspiration, respiratory distress syndrome (RDS, and cerebral ischemia. Curosurf was injected in a dose of 174.7±21 mg/kg in the infants with neonatal RDS at 35 minutes of life. All the babies included in the study were noted to have severe disease and prolonged MV. After stabilization of their status, the neonates received combination therapy involving surfactantBL inhalation to reduce the duration of MV. The dose of the agent was 75 mg. Results. After surfactantBL inhalation, effective spontaneous respiration occurred in 69.2% of the newborn infants; successful extubation was carried out. The median duration ofMV after surfactant BL inhalation was 22 hours (4—68 hours. There were no reintubated cases after inhalation therapy. Following surfactantBL inhalation, 4 (30.8% patients remained to be on MV as a control regimen; 3 of them had highfre quency MV. SurfactantBL inhalation made it possible to change the respiratory support regimen and to reduce MV parame ters in these babies. 

  15. Pharmacoeconomics of inhaled anesthetic agents: considerations for the pharmacist.

    Science.gov (United States)

    Chernin, Eric L

    2004-10-15

    Types of economic analyses used for inhaled anesthetic agents, factors to consider in calculating the cost of inhaled anesthetics, limitations of pharmacoeconomic studies of these agents, and strategies for controlling inhaled anesthetic costs are discussed. Inhaled anesthetic agents comprise a substantial component of drug budgets. Calculation of the cost of administering an inhaled anesthetic should take into consideration the cost per mL, potency, waste, concentration and duration of gas delivery, fresh gas flow rate, molecular weight, and density. The use of newer inhaled anesthetic agents with low solubility in blood and tissue provides a more rapid recovery from anesthesia than older, more soluble agents, and also provides the same level of control of depth of anesthesia at a lower fresh gas flow rate and possibly a lower cost than older agents at a higher fresh gas flow rate. A more rapid recovery may facilitate fast-track recovery and yield cost savings if it allows the completion of additional surgical cases or allows a reduction in personnel overtime expenses. Interpretation of pharmacoeconomic studies of inhaled anesthetics requires an appreciation of the limitations in methodology and ability to extrapolate results from one setting to another. Pharmacists' efforts to reduce anesthetic waste and collaborate with anesthesiologists to improve the use of these agents can help contain costs, but improving scheduling and efficiency in the operating room has a greater potential to reduce operating room costs. Much can be done to control costs of anesthetic agents without compromising availability of these agents and patient care.

  16. Factors related to the incorrect use of inhalers by asthma patients

    Directory of Open Access Journals (Sweden)

    Paulo de Tarso Roth Dalcin

    2014-01-01

    Full Text Available OBJECTIVE: To evaluate inhaler technique in outpatients with asthma and to determine associations between the correctness of that technique and the level of asthma control. METHODS: This was a cross-sectional study involving patients > 14 years of age with physician-diagnosed asthma. The patients were recruited from the Asthma Outpatient Clinic of the Hospital de Clínicas de Porto Alegre, in the city of Porto Alegre, Brazil. The patients completed two questionnaires (a general questionnaire and an asthma control questionnaire based on the 2011 Global Initiative for Asthma guidelines, demonstrated their inhaler technique, and performed pulmonary function tests. Incorrect inhaler technique was defined as the incorrect execution of at least two of the predefined steps. RESULTS: We included 268 patients. Of those, 81 (30.2% showed incorrect inhaler technique, which was associated with poor asthma control (p = 0.002. Logistic regression analysis identified the following factors associated with incorrect inhaler technique: being widowed (OR = 5.01; 95% CI, 1.74-14.41; p = 0.003; using metered dose inhalers (OR = 1.58; 95% CI, 1.35-1.85; p 2 comorbidities (OR = 3.80; 95% CI, 1.03-14.02; p = 0.045. CONCLUSIONS: In the sample studied, incorrect inhaler technique was associated with poor asthma control. Widowhood, use of metered dose inhalers, low socioeconomic level, and the presence of > 2 comorbidities were associated with incorrect inhaler technique.

  17. Characterization and modelling of low-pressure rf discharges at 2-500 MHz for miniature alkali vapour dielectric barrier discharge lamps

    International Nuclear Information System (INIS)

    Venkatraman, Vinu; Shea, Herbert; Pétremand, Yves; Rooij, Nico de

    2012-01-01

    Low-pressure dielectric barrier discharge (DBD) alkali vapour lamps are of particular interest for portable atomic clocks because they (1) could enable low-power operation, (2) generate the precise required wavelength, (3) are planar simplifying chip-level integration and (4) use external electrodes, which increases the lifetime. Given the stringent requirements on lamps for atomic clocks, it is important to identify the parameters that can be optimized to meet these performance requirements (size, power consumption, stability, reliability). We report on the electrical and optical characteristics of dielectric barrier plasma discharges observed in two configurations: (1) in a vacuum chamber over a wide low-pressure range (2-100 mbar) for three different buffer gases (He, Ar, N 2 ) driven at different frequencies between 2 and 500 MHz and (2) on microfabricated hermetically sealed Rb vapour cells filled with 30 and 70 mbar of Ar. We discuss the optimum conditions for a low-power and stable operation of a Rb vapour DBD lamp, aimed at chip-scale atomic clocks. We also present the electrical modelling of the discharge parameters to understand the power distribution mechanisms and the input power to discharge power coupling efficiency.

  18. Vertical distribution of deuterium in atmospheric water vapour: problems in application to assess atmospheric condensation models

    International Nuclear Information System (INIS)

    Taylor, C.B.

    1984-01-01

    The paper assesses the use of the author's data by Rozanski and Sonntag to support a multi-box model of the vertical distribution of deuterium in atmospheric water vapour, in which exchange between vapour and falling precipitation produces a steeper deuterium concentration profile than simpler condensation models. The mean deuterium/altitude profile adopted by Rozanski and Sonntag for this purpose is only one of several very different mean profiles obtainable from the data by arbitrary selection and weighting procedures; although it can be made to match the specified multi-box model calculations for deuterium, there is a wide discrepancy between the actual and model mean mixing ratio profiles which cannot be ignored. Taken together, the mixing ratio and deuterium profiles indicate that mean vapour of the middle troposphere has been subjected to condensation at greater heights and lower temperatures than those considered in the model calculations. When this is taken into account, the data actually fit much better to the simpler condensation models. But the vapour samples represent meteorological situations too remote in time from primary precipitation events to permit definite conclusions on cloud system mechanisms. (Auth.)

  19. Stable isotope characterization of pan-derived and directly sampled atmospheric water vapour

    International Nuclear Information System (INIS)

    Maric, R.; St. Amour, N.A.; Gibson, J.J.; Edwards, T.W.D.

    2002-01-01

    Isotopic characterization of atmospheric water vapour, δ A , and its temporal variability are important prerequisites for quantifying water balance of surface reservoirs and partitioning of evaporation and transpiration fluxes using isotope techniques. Here we present results from a detailed comparison of several methods for determining δ A in field situations, (i) by back-calculation from isotopic and micrometeorological monitoring of a steady-state terminal reservoir (standard Class-A evaporation pan) using boundary-layer mass transfer models [1], (ii) through direct (cryogenic) sampling of ambient atmospheric moisture, and (iii) using the precipitation-equilibrium approximation (i.e., δ A =δ P - ε*)

  20. Tritium gas and tritiated water vapour behaviour in the environment from releases into the atmosphere from fusion reactors

    International Nuclear Information System (INIS)

    Velarde, Marta; Perlado, Manuel

    2001-01-01

    The diffusion of tritium from fusion reactors follows different ways according to the present chemical form, tritium gas or tritiated water vapour. The atmospheric conditions, speed and direction of the wind, rain intensity or stability class, are key factors in the dry and wet deposition. The obtained results demonstrate that the wet deposition is critical for the incorporation of the tritiated water vapour to the natural biological chain. However, the dry deposition is the factor that influences in the tritium gas form. The conversion of HT into HTO in the soil is rapid (1-7 days), and 20% of HT deposited in the soil is reemitted to the atmosphere in the form HTO, while the rest incorporates into the biological cycle. The rain factor accelerates the incorporation of tritium to the ground, the superficial waters and the underground waters

  1. Rewetting of semi-dried ink patterns by vapour annealing for developing a reflow process in reverse offset printing

    International Nuclear Information System (INIS)

    Kusaka, Yasuyuki; Ushijima, Hirobumi; Sugihara, Kazuyoshi; Koutake, Masayoshi

    2017-01-01

    A process for reflowing patterned materials for reverse offset printing was developed, with the aim of mitigating the step-coverage problem in multilayered devices. The proposed reflow process involves a single step of vapour annealing at moderate temperatures ranging from 60 to 70 °C. This step successfully changes the height profile of semi-dried ink patterns formed on a silicone blanket, from an initially rectangular shape to a rounded shape. A systematic investigation on the effects of various vapour species and vapour temperatures on the reflow process revealed that the miscibility between the vapour and the ink, and a low boiling point of the respective solvent (high vapour pressure) are the prerequisites for successful reflows of semi-dried ink layers patterned on a silicone blanket. The results suggested that the rewetting of previously semi-dried patterns is the main mechanism in the reflow process, which led to a change in the height profile. Furthermore, the reflowed patterns demonstrated almost identical peak-height thicknesses, irrespective of the width of the patterns. This is a unique property that is unattainable by other printing methods, including gravure offset printing and microcontact printing, wherein printed patterns have rounded shapes without a reflow process, but their thickness inevitably depends on the pattern sizes. (technical note)

  2. Inhalation of Budesonide/Formoterol Increases Diaphragm Muscle Contractility

    Directory of Open Access Journals (Sweden)

    Chiyohiko Shindoh

    2012-01-01

    Conclusions: BUD/FORM inhalation has an inotropic effect on diaphragm muscle, protects diaphragm muscle deterioration after endotoxin injection, and inhibits NO production. Increments in muscle contractility with BUD/FORM inhalation are induced through a synergistic effect of an anti-inflammatory agent and 02-agonist.

  3. Social stigma stops adolescents from using inhalers for asthma.

    Science.gov (United States)

    2017-07-10

    Forgetfulness, poor routines, inadequate inhaler technique, organisational difficulties and families not understanding or accepting their children's asthma are described as barriers to the use of inhalers among adolescents with asthma.

  4. Evaluation of niobium dimethylamino-ethoxide for chemical vapour deposition of niobium oxide thin films

    International Nuclear Information System (INIS)

    Dabirian, Ali; Kuzminykh, Yury; Wagner, Estelle; Benvenuti, Giacomo; Rushworth, Simon; Hoffmann, Patrik

    2014-01-01

    Chemical vapour deposition (CVD) processes depend on the availability of suitable precursors. Precursors that deliver a stable vapour pressure are favourable in classical CVD processes, as they ensure process reproducibility. In high vacuum CVD (HV-CVD) process vapour pressure stability of the precursor is of particular importance, since no carrier gas assisted transport can be used. The dimeric Nb 2 (OEt) 10 does not fulfil this requirement since it partially dissociates upon heating. Dimethylamino functionalization of an ethoxy ligand of Nb(OEt) 5 acts as an octahedral field completing entity and leads to Nb(OEt) 4 (dmae). We show that Nb(OEt) 4 (dmae) evaporates as monomeric molecule and ensures a stable vapour pressure and, consequently, stable flow. A set of HV-CVD experiments were conducted using this precursor by projecting a graded molecular beam of the precursor onto the substrate at deposition temperatures from 320 °C to 650 °C. Film growth rates ranging from 8 nm·h −1 to values larger than 400 nm·h −1 can be obtained in this system illustrating the high level of control available over the film growth process. Classical CVD limiting conditions along with the recently reported adsorption–reaction limited conditions are observed and the chemical composition, and microstructural and optical properties of the films are related to the corresponding growth regime. Nb(OEt) 4 (dmae) provides a large process window of deposition temperatures and precursor fluxes over which carbon-free and polycrystalline niobium oxide films with growth rates proportional to precursor flux are obtained. This feature makes Nb(OEt) 4 (dmae) an attractive precursor for combinatorial CVD of niobium containing complex oxide films that are finding an increasing interest in photonics and photoelectrochemical water splitting applications. The adsorption–reaction limited conditions provide extremely small growth rates comparable to an atomic layer deposition (ALD) process

  5. Inhaled Steroids: First Line Treatment of Adult Asthma

    Directory of Open Access Journals (Sweden)

    André Cartier

    1995-01-01

    Full Text Available Corticosteroids are the most potent inhaled anti-inflammatory drugs for asthma treatment. This paper reviews the clinical evidence supporting the early use of inhaled steroids in asthma as a first line treatment. Inhaled steroids can probably alter the course of asthma, especially in mild asthmatics. Once they have been shown to improve control of asthma and even if the need for beta2-agonists is virtually nil, their use should be continued at low doses (ie, equivalent to 400 to 500 μg of budesonide or beclomethasone for at least one year before attempting to reduce the dosage.

  6. Real-life characteristics of asthma inhaler device use in South Korea

    NARCIS (Netherlands)

    Wan Yau Ming, S.; Rhee, C.K.; Park, H.Y.; Yoo, K.H.; Kim, D.K.; Van Boven, J.F.; Price, D.; Park, H.S.

    2016-01-01

    Background and Aims: Historically, dry powder inhalers (DPIs) were considered to provide better airway distribution, easier identification of empty devices, and easier handling when compared to pressurized metered dose inhalers (pMDIs). Prior research into the major handling errors with inhaler

  7. A high current metal vapour vacuum arc ion source for ion implantation studies

    International Nuclear Information System (INIS)

    Evans, P.J.; Noorman, J.T.; Watt, G.C.; Cohen, D.D.; Bailey, G.M.

    1989-01-01

    The main features of the metal vapour vacuum arc(MEVA) as an ion source are presented. The technology utilizes the plasma production capabilities of a vacuum arc cathode. Some of the ions produced in this discharge flow through the anode and the 3 extraction grids to form an extracted ion beam. The high beam current and the potential for generating broad beams, make this technology suitable for implantation of large surface areas. The composition of the vacuum arc cathode determines the particular ions obtained from the MEVA source. 3 refs., 1 tab., 2 figs

  8. Inhalant abuse in the youth : A reason for concern

    Directory of Open Access Journals (Sweden)

    J Simlai

    2008-01-01

    Full Text Available In recent times Inhalant or Volatile substances are emerging as a major drug of abuse in the preadolescent and adolescent age group. Most of the children are from broken homes and poor backgrounds. Inhalants have serious immediate and longterm side-effects and can also cause sudden sniffing death syndrome. It is difficult to control this ever-growing problem because Inhalants or Solvents are widely available. Management issues have been discussed in the review.

  9. Pirbuterol Acetate Oral Inhalation

    Science.gov (United States)

    ... Pirbuterol is in a class of medications called beta-agonist bronchodilators. It works by relaxing and opening ... cleaning. Once a week, remove the mouthpiece cover, turn the inhaler upside down and wipe the mouthpiece ...

  10. Education on Correct Inhaler Technique in Pharmacy Schools ...

    African Journals Online (AJOL)

    Conclusion: Standard educational training may not be the most appropriate method of teaching students the correct use of inhalers. Clearly, there is a practice element missing which needs to be addressed in a feasible way. Keywords: Inhaler technique, Pharmacy education, Hands-on training, Training barrier ...

  11. Inhaled Antibiotics for Gram-Negative Respiratory Infections

    Science.gov (United States)

    Fraidenburg, Dustin R.; Scardina, Tonya

    2016-01-01

    SUMMARY Gram-negative organisms comprise a large portion of the pathogens responsible for lower respiratory tract infections, especially those that are nosocomially acquired, and the rate of antibiotic resistance among these organisms continues to rise. Systemically administered antibiotics used to treat these infections often have poor penetration into the lung parenchyma and narrow therapeutic windows between efficacy and toxicity. The use of inhaled antibiotics allows for maximization of target site concentrations and optimization of pharmacokinetic/pharmacodynamic indices while minimizing systemic exposure and toxicity. This review is a comprehensive discussion of formulation and drug delivery aspects, in vitro and microbiological considerations, pharmacokinetics, and clinical outcomes with inhaled antibiotics as they apply to disease states other than cystic fibrosis. In reviewing the literature surrounding the use of inhaled antibiotics, we also highlight the complexities related to this route of administration and the shortcomings in the available evidence. The lack of novel anti-Gram-negative antibiotics in the developmental pipeline will encourage the innovative use of our existing agents, and the inhaled route is one that deserves to be further studied and adopted in the clinical arena. PMID:27226088

  12. The speed of sound in a gas–vapour bubbly liquid

    Science.gov (United States)

    Prosperetti, Andrea

    2015-01-01

    In addition to the vapour of the liquid, bubbles in cavitating flows usually contain also a certain amount of permanent gas that diffuses out of the liquid as they grow. This paper presents a simplified linear model for the propagation of monochromatic pressure waves in a bubbly liquid with these characteristics. Phase change effects are included in detail, while the gas is assumed to follow a polytropic law. It is shown that even a small amount of permanent gas can have a major effect on the behaviour of the system. Particular attention is paid to the low-frequency range, which is of special concern in flow cavitation. Numerical results for water and liquid oxygen illustrate the implications of the model. PMID:26442146

  13. The speed of sound in a gas-vapour bubbly liquid.

    Science.gov (United States)

    Prosperetti, Andrea

    2015-10-06

    In addition to the vapour of the liquid, bubbles in cavitating flows usually contain also a certain amount of permanent gas that diffuses out of the liquid as they grow. This paper presents a simplified linear model for the propagation of monochromatic pressure waves in a bubbly liquid with these characteristics. Phase change effects are included in detail, while the gas is assumed to follow a polytropic law. It is shown that even a small amount of permanent gas can have a major effect on the behaviour of the system. Particular attention is paid to the low-frequency range, which is of special concern in flow cavitation. Numerical results for water and liquid oxygen illustrate the implications of the model.

  14. Establishment and evaluation of a rat model of inhalation lung injury induced by ship smog

    Directory of Open Access Journals (Sweden)

    Xin-xin DUAN

    2018-03-01

    Full Text Available Objective To establish and evaluate a rat model of inhalation lung injury induced by ship smog. Methods A rat model of inhalation lung injury was established by analyzing the composition of ship materials after combustion. Forty- two healthy male Wistar rats were randomly divided into normal control group and 2, 6, 12, 24, 48 and 72h groups (6 eachafter inhalation, these rats were killed at each time point, and the changes of arterial blood gas, coagulation function, the lung water content (% were detected. Macroscopic and microscopic changes in lung tissues were observed to judge the degree of lung injury. Results The main components after combustion of 7 kinds of nonmetal materials on ship included CO, CO2, H2S, NOx and other harmful gases in this study, AIKE in one gas detector was used to monitor O2, CO, CO2 and H2S, and their concentrations remained relatively stable within 15 minutes, and the injury time was 15 minutes. The rats presented with shortness of breath and mouth breathing. Smoke inhalation caused a significant hypoxemia, the concentration of blood COHb reached a peak value 2h and the lung water content (% did 6h after inhalation (P<0.05. It is metabolic acidosis in the early stage after inhalation, but metabolic acidosis combined with respiratory acidosis in the later period. Histopathological observation showed diffuse hemorrhage, edema and inflammatory cell infiltration in the lung tissue as manifestations of lung injury, and the injury did not recover at 72h after inhalation, the change of blood coagulation function was not statistically significant. Conclusion A rat model of inhalation lung injury induced by ship smog has been successfully established, and has the advantages of easy replication, stability and reliability, thus can be used to research and treat inhalation lung injury induced by ship smog in naval war environment and other cases. DOI: 10.11855/j.issn.0577-7402.2018.03.14

  15. Measurement and modeling of high-pressure (vapour + liquid) equilibria of (CO2 + alcohol) binary systems

    International Nuclear Information System (INIS)

    Gutierrez, Jorge E.; Bejarano, Arturo; Fuente, Juan C. de la

    2010-01-01

    An apparatus based on a static-analytic method assembled in this work was utilized to perform high pressure (vapour + liquid) equilibria measurements with uncertainties estimated at 2 + 1-propanol), (CO 2 + 2-methyl-1-propanol), (CO 2 + 3-methyl-1-butanol), and (CO 2 + 1-pentanol) binary systems at temperatures of (313, 323, and 333) K, and at pressure range of (2 to 12) MPa. For all the (CO 2 + alcohol) systems, it was visually monitored to insure that there was no liquid immiscibility at the temperatures and pressures studied. The experimental results were correlated with the Peng-Robinson equation of state using the quadratic mixing rules of van der Waals with two adjustable parameters. The calculated (vapour + liquid) equilibria compositions were found to be in good agreement with the experimental values with deviations for the mol fractions <0.12 and <0.05 for the liquid and vapour phase, respectively.

  16. Food hypersensitivity by inhalation

    Directory of Open Access Journals (Sweden)

    Bahna Sami L

    2009-02-01

    Full Text Available Abstract Though not widely recognized, food hypersensitivity by inhalation can cause major morbidity in affected individuals. The exposure is usually more obvious and often substantial in occupational environments but frequently occurs in non-occupational settings, such as homes, schools, restaurants, grocery stores, and commercial flights. The exposure can be trivial, as in mere smelling or being in the vicinity of the food. The clinical manifestations can vary from a benign respiratory or cutaneous reaction to a systemic one that can be life-threatening. In addition to strict avoidance, such highly-sensitive subjects should carry self-injectable epinephrine and wear MedicAlert® identification. Asthma is a strong predisposing factor and should be well-controlled. It is of great significance that food inhalation can cause de novo sensitization.

  17. Effects of Radon inhalation on physiology and disorders

    International Nuclear Information System (INIS)

    Yamaoka, Kiyonori; Komoto, Yoshiaki

    1998-01-01

    In the first study, we administered Radon (Rn) to rabbits by inhalation and examined changes in the lipid peroxide (thiobarbituric acid reacting substances; TBARS) level, superoxide dismutase (SOD) activity and membrane fluidity in various organs to clarify the therapeutic effects of Rn. In the second study, we sprayed Rn spring water of various concentrations to rabbits to make the animals inhale them, and examined mainly the responses of biogenic amine neurotransmitters for clarifying the effects of Rn inhalation in the neuronal transmitter system. In the third study, indications for treatment at the Misasa Hot Spring, a Rn producing radioactive spring, include hypertension, diabetes mellitus and pain. To clarify its mechanisms of action on these conditions, we evaluated dynamic changes in blood components such as vasoactive substances after Rn inhalation. Vasodilation, alleviation of diabetic symptoms and morphine-like analgesic effects were observed, suggesting that these changes constitute part of the mechanisms of the Rn spring therapy on the above conditions. (J.P.N.)

  18. Human volunteer study with PGME: Eye irritation during vapour exposure

    NARCIS (Netherlands)

    Emmen, H.H.; Muijser, H.; Arts, J.H.E.; Prinsen, M.K.

    2003-01-01

    The objective of this study was to establish the possible occurrence of eye irritation and subjective symptoms in human volunteers exposed to propylene glycol monomethyl ether (PGME) vapour at concentrations of 0, 100 and 150 ppm. Testing was conducted in 12 healthy male volunteers using a repeated

  19. Assessment of inhalation dose sensitivity by physicochemical properties of airborne particulates containing naturally occurring radioactive materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Si Young; Choi, Cheol Kyu; Kim, Yong Geon; Choi, Won Chul; Kim, Kwang Pyo [Kyung Hee University, Seoul (Korea, Republic of)

    2015-12-15

    Facilities processing raw materials containing naturally occurring radioactive materials (NORM) may give rise to enhanced radiation dose to workers due to chronic inhalation of airborne particulates. Internal radiation dose due to particulate inhalation varies depending on particulate properties, including size, shape, density, and absorption type. The objective of the present study was to assess inhalation dose sensitivity to physicochemical properties of airborne particulates. Committed effective doses to workers resulting from inhalation of airborne particulates were calculated based on International Commission on Radiological Protection 66 human respiratory tract model. Inhalation dose generally increased with decreasing particulate size. Committed effective doses due to inhalation of 0.01μm sized particulates were higher than doses due to 100μm sized particulates by factors of about 100 and 50 for {sup 238}U and {sup 230}Th, respectively. Inhalation dose increased with decreasing shape factor. Shape factors of 1 and 2 resulted in dose difference by about 18 %. Inhalation dose increased with particulate mass density. Particulate mass densities of 11 g·cm{sup -3} and 0.7 g·cm{sup -3} resulted in dose difference by about 60 %. For {sup 238}U, inhalation doses were higher for absorption type of S, M, and F in that sequence. Committed effective dose for absorption type S of {sup 238}U was about 9 times higher than dose for absorption F. For {sup 230}Th, inhalation doses were higher for absorption type of F, M, and S in that sequence. Committed effective dose for absorption type F of {sup 230}Th was about 16 times higher than dose for absorption S. Consequently, use of default values for particulate properties without consideration of site specific physiochemical properties may potentially skew radiation dose estimates to unrealistic values up to 1-2 orders of magnitude. For this reason, it is highly recommended to consider site specific working materials and

  20. The use of inhaled mannitol in the diagnosis and management of asthma

    DEFF Research Database (Denmark)

    Sverrild, Asger; Porsbjerg, Celeste; Backer, Vibeke

    2012-01-01

    on inhaled mannitol from the first publication in 1997 until present (October 2011). It discusses the current knowledge on the clinical usefulness as a tool for diagnosing and managing asthma. EXPERT OPINION: Inhaled mannitol can be regarded as a safe, standardized, specific, but less sensitive, tool...... for the diagnosis of asthma in both children and adults. Discomfort, in terms of cough, during the test occurs in 85.3% of subjects, but rarely (1.3%) leads to discontinuation. Headache (6.1%), pharyngolaryngeal pain (2.6%) and cough (1.3%) are the most frequent adverse events that occur on the day of the test...

  1. Vapour pressures of uranium and uranium nitride over UN(s)

    International Nuclear Information System (INIS)

    Venugopal, V.; Kulkarni, S.G.; Subbanna, C.S.; Sood, D.D.

    1992-01-01

    The vaporization of uranium mononitride is investigated in the temperature range 1757 to 2400 K by Knudsen effusion cell mass spectrometry. The vaporization occurs incongruently by the preferential loss of nitrogen and the formation of U(1) in equilibrium with UN phase. In addition the vapour phase has U(g) and UN(g). The vapour pressure of U(g) and UN(g) are measured and their dependence with temperatures can be represented by: log(p U (Pa))=[(10.59±0.18)-(26857±357)/T(K)] (1757 UN (Pa))=[(12.19±0.57)-(37347±235)/T(K)] (2190 f G 0 (UN, g, T)(kJ/mol)=352.75-0.0494 T(K). The equilibrium constants for the dissociation of UN(s)(K 1 ) and UN(g)(K 2 ) into gaseous elements are given by: log(K 1 )=(13.03±0.18)-(42857±357)/T(K), log(K 2 )=(0.84±0.60)-(5510±427)/T(K). (orig.)

  2. Basic study on positive effects of radon inhalation on pet's health

    International Nuclear Information System (INIS)

    Kataoka, Takahiro; Sakoda, Akihiro; Kawabe, Atsushi; Hanamoto, Katsumi; Yamaoka, Kiyonori; Tokunaga, Rikizo

    2012-01-01

    Radon inhalation using our radon exposure device activated anti-oxidative function in some organs of mouse. To assess the possibility of its application to veterinary care, healthy dogs and cats with chronic renal failure were inhaled radon at a concentration of 5500 Bq/m 3 for 30 minutes every 2 days for 30 days. In result, radon inhalation within a relatively long time period significantly decreased the triglyceride level of dogs. On the other hand, some cats increased the volume of drinking water by radon inhalation and the creatinine level in blood of these cats was decreased to normal level. These findings suggest that radon inhalation may have curative properties against chronic renal failure. (author)

  3. Inhalation Toxicology Research Institute annual report, October 1, 1993--September 30, 1994

    International Nuclear Information System (INIS)

    Belinsky, S.A.; Hoover, M.D.; Bradley, P.L.

    1994-11-01

    This document from the Inhalation Toxicology Research Institute includes annual reports in the following general areas: (I) Aerosol Technology and Characterization of Airborne Materials; (II) Deposition, transport, and clearance of inhaled Toxicants; (III) Metabolism and Markers of Inhaled Toxicants; (IV) Carcinogenic Responses to Toxicants; (V) Mechanisms of carcinogenic response to Toxicants; (VI) Non carcinogenic responses to inhaled toxicants; (VII) Mechanisms of noncarcinogenic Responses to Inhaled Toxicants; (VIII) The application of Mathematical Modeling to Risk Estimates. 9 appendices are also included. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database

  4. Inhalation Toxicology Research Institute annual report, October 1, 1993--September 30, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Belinsky, S. A.; Hoover, M. D.; Bradley, P. L. [eds.

    1994-11-01

    This document from the Inhalation Toxicology Research Institute includes annual reports in the following general areas: (I) Aerosol Technology and Characterization of Airborne Materials; (II) Deposition, transport, and clearance of inhaled Toxicants; (III) Metabolism and Markers of Inhaled Toxicants; (IV) Carcinogenic Responses to Toxicants; (V) Mechanisms of carcinogenic response to Toxicants; (VI) Non carcinogenic responses to inhaled toxicants; (VII) Mechanisms of noncarcinogenic Responses to Inhaled Toxicants; (VIII) The application of Mathematical Modeling to Risk Estimates. 9 appendices are also included. Selected papers are indexed separately for inclusion in the Energy Science and Technology Database.

  5. Improved grand canonical sampling of vapour-liquid transitions.

    Science.gov (United States)

    Wilding, Nigel B

    2016-10-19

    Simulation within the grand canonical ensemble is the method of choice for accurate studies of first order vapour-liquid phase transitions in model fluids. Such simulations typically employ sampling that is biased with respect to the overall number density in order to overcome the free energy barrier associated with mixed phase states. However, at low temperature and for large system size, this approach suffers a drastic slowing down in sampling efficiency. The culprits are geometrically induced transitions (stemming from the periodic boundary conditions) which involve changes in droplet shape from sphere to cylinder and cylinder to slab. Since the overall number density does not discriminate sufficiently between these shapes, it fails as an order parameter for biasing through the transitions. Here we report two approaches to ameliorating these difficulties. The first introduces a droplet shape based order parameter that generates a transition path from vapour to slab states for which spherical and cylindrical droplets are suppressed. The second simply biases with respect to the number density in a tetragonal subvolume of the system. Compared to the standard approach, both methods offer improved sampling, allowing estimates of coexistence parameters and vapor-liquid surface tension for larger system sizes and lower temperatures.

  6. The chemo and the mona : Inhalants, devotion and street youth in Mexico city

    NARCIS (Netherlands)

    Gigengack, Roy

    This paper understands inhalant use - the deliberate inhalation of volatile solvents or glues with intentions of intoxication - as a socially and culturally constituted practice. It describes the inhalant use of young street people in Mexico City from their perspective ("the vicioso or inhalant

  7. Effectiveness of the different methods of inhalation drugs delivery in children with bronchial asthma

    Directory of Open Access Journals (Sweden)

    S.M. Nedelska

    2017-02-01

    Full Text Available Aim of the work — to evaluate the effectiveness of inhalation technique when using different types of inhalers (dry powder inhalers — Turbuhaler, Diskus, metered-dose inhalers, breath-actuated inhalers — Easyhaler. Materials and methods. 45 patients aged 6–17 years underwent the evaluation of inhalation technique accuracy with the use of In-Check-Dial — apparatus, which imitates the airway resistance that should be overcome during inspiration through different inhaler types, and measure inspiration velocity. Incidence of mistakes was studied in different age groups. Results. 80 % of children aged 6–7 years made mistakes while using Turbuhaler, 73.3 % — metered-dose inhaler, 60 % — Easyhaler. There were no mistakes in patients making inhalation by means of Diskhaler. 100 % of children aged 12–14 years incorrectly used metered-dose inhaler. Easyhaler was incorrectly used in 66.6 % of cases, Diskhaler — in 26.6 %. Among elder group, incidence of mistakes when making inhalations through Turbuhaler was lower — 40 % in 12–14-year-old group and 25 % — in 15–17-year-old (р < 0.05. Children of 15–17 years old are able to use Turbuhaler and Diskus (mistakes in 33.3 and 46.6 %, respectively. At the same time, none of the patients have done the correct inhalation by means of metered-dose inhaler, 93.3 % of the patients have mistakes when using Easyhaler. Conclusions. The incidence of mistakes depends on the age and inhaler type and reaches 26–100 %. Minimal quantity of mistakes is seen for Diskus (in all age groups, maxi­mal — for metered-dose inhaler. For the purpose of optimal inhaler choice in a child with bronchial asthma, it is advisable to measure the inspiratory flow with the help of In-Check-Dial before therapy administration.

  8. A Raman lidar at La Reunion (20.8° S, 55.5° E for monitoring water vapour and cirrus distributions in the subtropical upper troposphere: preliminary analyses and description of a future system

    Directory of Open Access Journals (Sweden)

    C. Hoareau

    2012-06-01

    Full Text Available A ground-based Rayleigh lidar has provided continuous observations of tropospheric water vapour profiles and cirrus cloud using a preliminary Raman channels setup on an existing Rayleigh lidar above La Reunion over the period 2002–2005. With this instrument, we performed a first measurement campaign of 350 independent water vapour profiles. A statistical study of the distribution of water vapour profiles is presented and some investigations concerning the calibration are discussed. Analysis regarding the cirrus clouds is presented and a classification has been performed showing 3 distinct classes. Based on these results, the characteristics and the design of a future lidar system, to be implemented at the new Reunion Island altitude observatory (2200 m for long-term monitoring, is presented and numerical simulations of system performance have been realised to compare both instruments.

  9. Low pressure water vapour plasma treatment of surfaces for biomolecules decontamination

    DEFF Research Database (Denmark)

    Fumagalli, F; Kylian, O; Amato, Letizia

    2012-01-01

    Decontamination treatments of surfaces are performed on bacterial spores, albumin and brain homogenate used as models of biological contaminations in a low-pressure, inductively coupled plasma reactor operated with water-vapour-based gas mixtures. It is shown that removal of contamination can...... be achieved using pure H2O or Ar/H2O mixtures at low temperatures with removal rates comparable to oxygen-based mixtures. Particle fluxes (Ar+ ions, O and H atomic radicals and OH molecular radicals) from water vapour discharge are measured by optical emission spectroscopy and Langmuir probe under several...... operating conditions. Analysis of particle fluxes and removal rates measurements illustrates the role of ion bombardment associated with O radicals, governing the removal rates of organic matter. Auxiliary role of hydroxyl radicals is discussed on the basis of experimental data. The advantages of a water...

  10. Polarized Raman spectroscopy of chemically vapour deposited diamond films

    International Nuclear Information System (INIS)

    Prawer, S.; Nugent, K.W.; Weiser, P.S.

    1994-01-01

    Polarized micro-Raman spectra of chemically vapour deposited diamond films are presented. It is shown that important parameters often extracted from the Raman spectra such as the ratio of the diamond to non-diamond component of the films and the estimation of the level of residual stress depend on the orientation of the diamond crystallites with respect to the polarization of the incident laser beam. The dependence originates from the fact that the Raman scattering from the non-diamond components in the films is almost completely depolarized whilst the scattering from the diamond components is strongly polarized. The results demonstrate the importance of taking polarization into account when attempting to use Raman spectroscopy in even a semi-quantitative fashion for the assessment of the purity, perfection and stress in CVD diamond films. 8 refs., 1 tab. 2 figs

  11. Turkish Undergraduates' Misconceptions of Evaporation, Evaporation Rate, and Vapour Pressure

    Science.gov (United States)

    Canpolat, Nurtac

    2006-01-01

    This study focused on students' misconceptions related to evaporation, evaporation rate, and vapour pressure. Open-ended diagnostic questions were used with 107 undergraduates in the Primary Science Teacher Training Department in a state university in Turkey. In addition, 14 students from that sample were interviewed to clarify their written…

  12. Isobaric (vapour + liquid) equilibrium for N-methyl-2-pyrrolidone with branched alcohols

    International Nuclear Information System (INIS)

    Gnanakumari, P.; Venkatesu, P.; Hsieh, C.-T.; Rao, M.V. Prabhakara; Lee, M.-J.; Lin, Ho-mu

    2009-01-01

    The (vapour + liquid) equilibrium (VLE) and boiling temperature measurements have been determined at 95.3 kPa as a function of composition for the binary liquid mixtures of N-methyl-2-pyrrolidone (NMP) with branched alcohols using a Swietoslawski-ebulliometer. The branched alcohols include 2-propanol, 2-butanol, 2-methyl-l- propanol, 2-methyl-2-propanol, and 3-methyl-l-butanol. The experimental temperature-composition (T-x) results were used to estimate Wilson parameters and then used to calculate the equilibrium vapour compositions and the excess Gibbs free energy at T = 298.15 K. The experimental temperature-composition (T, x) results were correlated with the Wilson, the NRTL and the UNIQUAC models. The experimental results are interpreted in terms of intermolecular interactions between constituent molecules

  13. The water vapour continuum in near-infrared windows - Current understanding and prospects for its inclusion in spectroscopic databases

    Science.gov (United States)

    Shine, Keith P.; Campargue, Alain; Mondelain, Didier; McPheat, Robert A.; Ptashnik, Igor V.; Weidmann, Damien

    2016-09-01

    Spectroscopic catalogues, such as GEISA and HITRAN, do not yet include information on the water vapour continuum that pervades visible, infrared and microwave spectral regions. This is partly because, in some spectral regions, there are rather few laboratory measurements in conditions close to those in the Earth's atmosphere; hence understanding of the characteristics of the continuum absorption is still emerging. This is particularly so in the near-infrared and visible, where there has been renewed interest and activity in recent years. In this paper we present a critical review focusing on recent laboratory measurements in two near-infrared window regions (centred on 4700 and 6300 cm-1) and include reference to the window centred on 2600 cm-1 where more measurements have been reported. The rather few available measurements, have used Fourier transform spectroscopy (FTS), cavity ring down spectroscopy, optical-feedback - cavity enhanced laser spectroscopy and, in very narrow regions, calorimetric interferometry. These systems have different advantages and disadvantages. Fourier Transform Spectroscopy can measure the continuum across both these and neighbouring windows; by contrast, the cavity laser techniques are limited to fewer wavenumbers, but have a much higher inherent sensitivity. The available results present a diverse view of the characteristics of continuum absorption, with differences in continuum strength exceeding a factor of 10 in the cores of these windows. In individual windows, the temperature dependence of the water vapour self-continuum differs significantly in the few sets of measurements that allow an analysis. The available data also indicate that the temperature dependence differs significantly between different near-infrared windows. These pioneering measurements provide an impetus for further measurements. Improvements and/or extensions in existing techniques would aid progress to a full characterisation of the continuum - as an example, we

  14. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    Directory of Open Access Journals (Sweden)

    Mingrong Zhang

    2016-05-01

    Full Text Available The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-deep waveforms were matched within reasonable accuracy. Finally, with the help of dynamic image processing, the aerosol-release time (Tr was carefully measured and fully discussed, including the switch-on time (Ts, the mechatronics-hysteresis (Tm and the intentional-delay (Ti. Under slow-deep inhalation condition which is suitable for metered dose inhaler medicine delivery, the switch-on flow-rate could reach as low as 10 L/min, and the corresponding switch-on time was approximately 0.20 s. While the mechatronics-hysteresis depended on the brand of metered dose inhaler, assuming there was no intentional-delay, the aerosol-release time could be as low as 0.40 and 0.60 s, respectively, for two commercially available metered dose inhalers studied in this article. Therefore, this newly developed mechatronic adapter system could ensure aerosol-release time (Tr within satisfactory range for metered dose inhalers.

  15. Demographic and contextual factors associated with inhalant use among youth in rural Alaska

    Directory of Open Access Journals (Sweden)

    David L. Driscoll

    2012-04-01

    Full Text Available Background: Abuse of harmful legal products that can be inhaled or ingested is a serious and growing problem in many rural Alaskan communities, and particularly so among preteens. Methods: This study analyses data collected during baseline measurements of a 5-year NIH/NIDA-funded study entitled A Community Trial to Prevent Youth's Abuse of Harmful Legal Products in Alaska. Youth in 8 communities located throughout the state participated in a survey during the fall of 2009 to measure the prevalence and availability of harmful legal products (n=697. The goal of the analysis presented here is to compare the contextual factors of inhalant users and non-users in rural Alaskan communities. Results: As reported in national surveys of substance use among youth, participants in this study indicated using alcohol more than any other substance. Inhalants were the second-most common substance abused, higher than either cigarettes or marijuana. Lifetime use varied among demographic factors such as age, gender and ethnicity as well as contextual factors including academic performance, parent employment, household living situation and income. When compared to non-users, significantly larger proportions of participants reporting lifetime inhalant use indicated easy availability of inhalants in their home, school and retail outlets. Users were also significantly more likely than non-users to have consumed alcohol. Conclusion: Results of this study may inform the development of effective interventions in other rural communities.

  16. Oxidative stress in a rat model of cotton smoke inhalation-induced ...

    African Journals Online (AJOL)

    Background: Smoke inhalation injury refers to airway and lung parenchyma injury and general chemical damage caused by inhaling toxic gases and substances. The aim of this study was to explore the oxidative stress mechanism of cotton smoke inhalation-induced pulmonary injury in a rat model. Materials and Methods: ...

  17. Dose-Dependent Protective Effect of Inhalational Anesthetics Against Postoperative Respiratory Complications

    DEFF Research Database (Denmark)

    Grabitz, Stephanie D; Farhan, Hassan N; Ruscic, Katarina J

    2017-01-01

    OBJECTIVES: Inhalational anesthetics are bronchodilators with immunomodulatory effects. We sought to determine the effect of inhalational anesthetic dose on risk of severe postoperative respiratory complications. DESIGN: Prospective analysis of data on file in surgical cases between January 2007...... with endotracheal intubation. INTERVENTIONS: Median effective dose equivalent of inhalational anesthetics during surgery (derived from mean end-tidal inhalational anesthetic concentrations). MEASUREMENTS AND MAIN RESULTS: Postoperative respiratory complications occurred in 6,979 of 124,497 cases (5.61%). High...... inhalational anesthetic dose of 1.20 (1.13-1.30) (median [interquartile range])-fold median effective dose equivalent versus 0.57 (0.45-0.64)-fold median effective dose equivalent was associated with lower odds of postoperative respiratory complications (odds ratio, 0.59; 95% CI, 0.53-0.65; p

  18. Dosage of DTPA administration by inhalation

    International Nuclear Information System (INIS)

    Koizumi, Akira; Fukuda, Satoshi; Yamada, Yuji; Iida, Haruzo; Shimo, Michikuni

    2000-01-01

    The administration of DTPA by inhalation was examined as an emergency medical treatment. In order to estimate the practical dosage to the human, an accurate model of the human air way was connected to a anesthetizer and respiration was simulated. Ca-DTPA, aerosolized by an ultra-sonic nebulizer, was administered by inhalation to the model. For the experiments, the respiratory volume (tidal volume) and the respiration rate was 12 per minute. Irrigation water from the model of larynx and mouth, and the air filter were collected and measured by chelate titration in order to determine the quantity of aerosolized DTPA and the amount deposited on the trachea and lang. The results indicated that the quantity of aerosolized DTPA varied with dilution of the DTPA solution in a ample. It was found that a 3 time dilution was the most practical and that 73 mg of DTPA per minute could be aerosolized. Furthermore, the results indicated that 46% of the aerosolized DTPA was taken in through inhalation and that 26% of DTPA was deposited in the trachea and lung. These results suggest that in practical application in the emergency medical treatment, 15 minutes of inhalation could delivered to approximately 500 mg of DTPA, and 130 mg could be delivered to the trachea and lung. It is considered that these quantity are enough amount to increase the effects of radioactive nuclides from the body, comparing with the recommended dosage for injection administration. (author)

  19. Water vapour measurements during POLINAT 1

    Energy Technology Data Exchange (ETDEWEB)

    Ovarlez, J.; Ovarlez, H. [Centre National de la Recherche Scientifique, 91 - Palaiseau (France). Lab. de Meteorologie Dynamique

    1997-12-31

    The POLINAT (POLlution from aircraft emissions In the North ATlantic flight corridor)1 experiment has been performed within the framework of the Environment Programme of the Commission of the European Community. It was devoted to the study of the pollution from aircraft in the North Atlantic flight corridor, in order to investigate the impact of pollutants emitted by aircraft on the concentrations of ozone and other trace gases in the upper troposphere and lower stratosphere. For that experiment the water vapour content was measured with a frost-point hygrometer on board of the DLR Falcon research aircraft. This instrument is described, and some selected results are given. (author) 19 refs.

  20. Water vapour measurements during POLINAT 1

    Energy Technology Data Exchange (ETDEWEB)

    Ovarlez, J; Ovarlez, H [Centre National de la Recherche Scientifique, 91 - Palaiseau (France). Lab. de Meteorologie Dynamique

    1998-12-31

    The POLINAT (POLlution from aircraft emissions In the North ATlantic flight corridor)1 experiment has been performed within the framework of the Environment Programme of the Commission of the European Community. It was devoted to the study of the pollution from aircraft in the North Atlantic flight corridor, in order to investigate the impact of pollutants emitted by aircraft on the concentrations of ozone and other trace gases in the upper troposphere and lower stratosphere. For that experiment the water vapour content was measured with a frost-point hygrometer on board of the DLR Falcon research aircraft. This instrument is described, and some selected results are given. (author) 19 refs.

  1. The Chemo and the Mona: Inhalants, devotion and street youth in Mexico City

    NARCIS (Netherlands)

    Gigengack, R.A.

    2014-01-01

    This paper understands inhalant use – the deliberate inhalation of volatile solvents or glues with intentions of intoxication – as a socially and culturally constituted practice. It describes the inhalant use of young street people in Mexico City from their perspective (“the vicioso or inhalant

  2. Application of lemongrass oil in vapour phase for the effective control of anthracnose of 'Sekaki' papaya.

    Science.gov (United States)

    Ali, A; Wee Pheng, T; Mustafa, M A

    2015-06-01

    To evaluate the potential use of lemongrass essential oil vapour as an alternative for synthetic fungicides in controlling anthracnose of papaya. Lemongrass oil used in the study was characterized using gas chromatography-flame ionization detection (GC-FID) before it was tested against anthracnose of papaya in vitro and in vivo. The GC-FID analysis showed that geranial (45·6%) and neral (34·3%) were the major components in lemongrass oil. In vitro study revealed that lemongrass oil vapour at all concentrations tested (33, 66, 132, 264 and 528 μl l(-1) ) suppressed the mycelial growth and conidial germination of Colletotrichum gloeosporioides. For the in vivo study, 'Sekaki' papaya were exposed to lemongrass oil fumigation (0, 7, 14, 28 μl l(-1) ) for 18 h and at room temperature for 9 days. Lemongrass oil vapour at the concentration of 28 μl l(-1) was most effective against anthracnose of artificially inoculated papaya fruit while quality parameters of papaya were not significantly altered. This suggests that lemongrass oil vapour can control anthracnose disease development on papaya without affecting its natural ripening process. The potential practical application of this technology can reduce reliance on synthetic fungicides for the control of postharvest diseases in papaya. © 2015 The Society for Applied Microbiology.

  3. Inhalation dose due to indoor radon and thoron concentrations in the surrounding villages of Hyderabad, Andhra Pradesh, India

    International Nuclear Information System (INIS)

    Sreenath Reddy, M.; Sreenivasa Reddy, B.; Yadagiri Reddy, P.; Gopal Reddy, Ch.; Rama Reddy, K.

    2006-01-01

    Inhalation of radon, thoron and their decay products is the major contribution to the total radioactive dose received by the human population from the natural radiation. The indoor inhalation doses due to radon, thoron and their progenies in the surrounding villages of Hyderabad, India are evaluated. The average inhalation dose due to radon and its progeny is found to be 0.26 ± 0.21 mSv y -1 and due to thoron and its progeny is 0.35 ± 0.38 mSv y -1 . The inhalation dose is also analyzed based on the types of floor, roof and walls of the dwellings and it is found that the dwellings with mud type construction materials have higher inhalation dose. Generally, the contribution of thoron and its progeny to the total dose is neglected but in the present study area the fractional dose of thoron and its progeny is found to be comparable to that of radon and its progeny. (author)

  4. Lung deposition of inhaled drugs increases with age

    DEFF Research Database (Denmark)

    Onhøj, J; Thorsson, L; Bisgaard, H

    2000-01-01

    Budesonide plasma concentrations after inhalation of a fixed dose of the drug from a pressurized metered dose inhaler (pMDI) with spacer (Nebuchamber) were compared in young children and adults: 26 patients with mild asthma comprising 8 children 2-3 yr, 8 children 4-6 yr, and 10 adults 20-41 yr...

  5. Towards the optimisation and adaptation of dry powder inhalers.

    Science.gov (United States)

    Cui, Y; Schmalfuß, S; Zellnitz, S; Sommerfeld, M; Urbanetz, N

    2014-08-15

    Pulmonary drug delivery by dry powder inhalers is becoming more and more popular. Such an inhalation device must insure that during the inhalation process the drug powder is detached from the carrier due to fluid flow stresses. The goal of the project is the development of a drug powder detachment model to be used in numerical computations (CFD, computational fluid dynamics) of fluid flow and carrier particle motion through the inhaler and the resulting efficiency of drug delivery. This programme will be the basis for the optimisation of inhaler geometry and dry powder inhaler formulation. For this purpose a multi-scale approach is adopted. First the flow field through the inhaler is numerically calculated with OpenFOAM(®) and the flow stresses experienced by the carrier particles are recorded. This information is used for micro-scale simulations using the Lattice-Boltzmann method where only one carrier particle covered with drug powder is placed in cubic flow domain and exposed to the relevant flow situations, e.g. plug and shear flow with different Reynolds numbers. Therefrom the fluid forces on the drug particles are obtained. In order to allow the determination of the drug particle detachment possibility by lift-off, sliding or rolling, also measurements by AFM (atomic force microscope) were conducted for different carrier particle surface structures. The contact properties, such as van der Waals force, friction coefficient and adhesion surface energy were used to determine, from a force or moment balance (fluid forces versus contact forces), the detachment probability by the three mechanisms as a function of carrier particle Reynolds number. These results will be used for deriving the drug powder detachment model. Copyright © 2014 Elsevier B.V. All rights reserved.

  6. Cerebral blood flow (CBF) with 133Xe inhalation method

    International Nuclear Information System (INIS)

    Kusunoki, Tadaki; Masumura, Michio; Tamaki, Norihiko; Matsumoto, Satoshi; Yamashita, Hideyuki.

    1982-01-01

    The effects of CO 2 inhalation on the cerebral blood flow (CBF) were examined with 133 Xe inhalation method (Novo Inhalation Cerebrograph) on 9 normal peoples and 20 patients. Nine normal peoples were divided into 3 groups consisting of each 3 peoples, namely young age group, middle age group, and old age group. Each increased CBF (%) by CO 2 inhalation was 40 -- 44 in young age group, 36 -- 37 in middle age group, and 35 -- 36 in old age group in the blood flow of the first compartment (F 1 ), and 27 -- 28 in young age group, 30 -- 31 in middle age group and 23 -- 24 in old age group in the initial slope index (ISI). Each CO 2 reactivity factor (RF) was 5.5 -- 5.8 in young age group, 3.8 -- 4.0 in middle age group and 3.3 in old age group in F 1 , and 3.1 -- 3.2 in young age group, 2.0 -- 3.3 in middle age group, and 1.2 -- 1.3 in old age group in ISI. Twenty patients consisted of 15 patients of occlusive cerebrovascular disease, 2 patients of head injury, 2 patients of normal pressure hydrocephalus and one patient of subarachnoid hemorrhage. RF was abnormally lower than normal value in 5 patients in F 1 , but in 7 in ISI. Clinical benefits of CBF study during CO 2 inhalation with 133 Xe inhalation method were discussed. (author)

  7. Consistent vapour-liquid equilibrium data containing lipids

    DEFF Research Database (Denmark)

    Cunico, Larissa; Ceriani, Roberta; Sarup, Bent

    Consistent physical and thermodynamic properties of pure components and their mixtures are important for process design, simulation, and optimization as well as design of chemical based products. In the case of lipids, it was observed a lack of experimental data for pure compounds and also...... for their mixtures in open literature, what makes necessary the development of reliable predictive models based on limited data. To contribute to the missing data, measurements of isobaric vapour-liquid equilibrium (VLE) data of three binary mixtures at two different pressures were performed at State University...

  8. Experiments on a vapour absorption heat transformer

    Energy Technology Data Exchange (ETDEWEB)

    George, J M; Murthy, S S [Indian Inst. of Tech., Madras (India). Dept. of Mechanical Engineering

    1993-03-01

    Tests were conducted on a 3 kW heating capacity R21-DMF vapour absorption heat transformer to study the influence of operating temperature on its performance. Heat source temperature and condensing temperature were varied in the ranges 50-75[sup o]C and 20-40[sup o]C, respectively. Heat delivery temperatures up to 85[sup o]C and temperature lifts up to 20[sup o]C were achieved. Actual coefficients of performance (COPs) ranged from 0.2 to 0.35, whereas exergetic efficiencies of 0.3-0.4 could be obtained. (Author)

  9. Accidental Cutaneous Burns Secondary to Salbutamol Metered Dose Inhaler

    Directory of Open Access Journals (Sweden)

    Ashutosh Kale

    2010-01-01

    Full Text Available We report a case of accidental cutaneous burns caused by salbutamol metered dose inhaler. A 9-year-old boy underwent dental extraction at a children's hospital and was incidentally noted to have burn injuries on dorsum of both hands. On questioning, the boy revealed that a few days ago his 14-year-old brother, who is an asthmatic, playfully sprayed his salbutamol metered dose inhaler on the back of both his hands with the inhaler's mouth piece being in direct contact with the patient's skin. On examination, there was a rectangular area of erythema with superficial peeling on the dorsum of both hands, the dimensions of which exactly matched those of the inhaler's mouthpiece. It is possible that the injury could have been a chemical burn from the pharmaceutical/preservative/propellant aerosol or due to the physical effect of severe cooling of the skin or mechanical abrasive effect of the aerosol blasts or a combination of some or all the above mechanisms. This case highlights the importance of informing children and parents of the potentially hazardous consequences of misusing a metered dose inhaler.

  10. Electron drift velocities in He and water mixtures: Measurements and an assessment of the water vapour cross-section sets

    International Nuclear Information System (INIS)

    Urquijo, J. de; Juárez, A. M.; Basurto, E.; Ness, K. F.; Robson, R. E.; White, R. D.; Brunger, M. J.

    2014-01-01

    The drift velocity of electrons in mixtures of gaseous water and helium is measured over the range of reduced electric fields 0.1–300 Td using a pulsed-Townsend technique. Admixtures of 1% and 2% water to helium are found to produce negative differential conductivity (NDC), despite NDC being absent from the pure gases. The measured drift velocities are used as a further discriminative assessment on the accuracy and completeness of a recently proposed set of electron-water vapour cross-sections [K. F. Ness, R. E. Robson, M. J. Brunger, and R. D. White, J. Chem. Phys. 136, 024318 (2012)]. A refinement of the momentum transfer cross-section for electron-water vapour scattering is presented, which ensures self-consistency with the measured drift velocities in mixtures with helium to within approximately 5% over the range of reduced fields considered

  11. Once-daily use of inhaled corticosteroids: A new regimen in the treatment of persistent asthma

    Directory of Open Access Journals (Sweden)

    Jeffrey Leflein

    2000-01-01

    Strict patient adherence with prescribed anti-inflammatory medication is crucial for obtaining optimal therapeutic benefit for patients with asthma. Despite the proven effectiveness of inhaled corticosteroids, patient adherence to prescribed therapy is often low, resulting in increased patient morbidity. Complex dosing regimens contribute greatly to patient non-adherence. Thus, new once-daily regimens of inhaled corticosteroid treatment have been introduced as means to improve patient adherence and provide optimal therapeutic benefit. In the present review, the complex inflammatory and remodeling processes in asthma and their contributions to the clinical manifestations of the disease will be discussed. Currently available, once-daily inhaled corticosteroid treatment options and the advantages of these therapeutic options in the treatment of persistent asthma also will be discussed.

  12. Analysing the mechanisms of soil water and vapour transport in the desert vadose zone of the extremely arid region of northern China

    Science.gov (United States)

    Du, Chaoyang; Yu, Jingjie; Wang, Ping; Zhang, Yichi

    2018-03-01

    The transport of water and vapour in the desert vadose zone plays a critical role in the overall water and energy balances of near-surface environments in arid regions. However, field measurements in extremely dry environments face many difficulties and challenges, so few studies have examined water and vapour transport processes in the desert vadose zone. The main objective of this study is to analyse the mechanisms of soil water and vapour transport in the desert vadose zone (depth of ∼350 cm) by using measured and modelled data in an extremely arid environment. The field experiments are implemented in an area of the Gobi desert in northwestern China to measure the soil properties, daily soil moisture and temperature, daily water-table depth and temperature, and daily meteorological records from DOYs (Days of Year) 114-212 in 2014 (growing season). The Hydrus-1D model, which simulates the coupled transport of water, vapour and heat in the vadose zone, is employed to simulate the layered soil moisture and temperature regimes and analyse the transport processes of soil water and vapour. The measured results show that the soil water and temperatures near the land surface have visible daily fluctuations across the entire soil profile. Thermal vapour movement is the most important component of the total water flux and the soil temperature gradient is the major driving factor that affects vapour transport in the desert vadose zone. The most active water and heat exchange occurs in the upper soil layer (depths of 0-25 cm). The matric potential change from the precipitation mainly re-draws the spatio-temporal distribution of the isothermal liquid water in the soil near the land surface. The matric potential has little effect on the isothermal vapour and thermal liquid water flux. These findings offer new insights into the liquid water and vapour movement processes in the extremely arid environment.

  13. [Methemoglobinemia after inhalation of poppers].

    Science.gov (United States)

    Janssens, U; Hillen, S; Janssens, T; Grafe, J

    2018-04-17

    This case report presents a case of symptomatic methemoglobinemia (MetHb 31.6%) after inhalation of volatile nitrites (poppers). The patient's medical history and symptoms are discussed together with pathophysiology of methemoglobinemia, diagnostics, and antidote therapy. Pulse oxymetry, arterial blood gas analysis, and CO-oximetry receive particular attention as well as antidote therapy with methylene blue. The patient was treated successfully with intravenous methylene blue. Within 60 min methemoglobinemia returned to normal values (MetHb 0.6%). Stimulating compounds such as volatile nitrites (poppers) may lead to potentially fatal methemoglobinemia. Swift and accurate diagnosis and targeted therapy with methylene blue can lead to rapid recovery.

  14. Physical properties of chemical vapour deposited nanostructured carbon thin films

    International Nuclear Information System (INIS)

    Mahadik, D.B.; Shinde, S.S.; Bhosale, C.H.; Rajpure, K.Y.

    2011-01-01

    Research highlights: In the present paper, nanostructured carbon films are grown using a natural precursor 'turpentine oil (C 10 H 16 )' as a carbon source in the simple thermal chemical vapour deposition method. The influence of substrate surface topography (viz. stainless steel, fluorine doped tin oxide coated quartz) and temperature on the evolution of carbon allotropes surfaces topography/microstructural and structural properties are investigated and discussed. - Abstract: A simple thermal chemical vapour deposition technique is employed for the deposition of carbon films by pyrolysing the natural precursor 'turpentine oil' on to the stainless steel (SS) and FTO coated quartz substrates at higher temperatures (700-1100 deg. C). In this work, we have studied the influence of substrate and deposition temperature on the evolution of structural and morphological properties of nanostructured carbon films. The films were characterized by using X-ray diffraction (XRD), scanning electron microscopy (SEM), contact angle measurements, Fourier transform infrared (FTIR) and Raman spectroscopy techniques. XRD study reveals that the films are polycrystalline exhibiting hexagonal and face-centered cubic structures on SS and FTO coated glass substrates respectively. SEM images show the porous and agglomerated surface of the films. Deposited carbon films show the hydrophobic nature. FTIR study displays C-H and O-H stretching vibration modes in the films. Raman analysis shows that, high ID/IG for FTO substrate confirms the dominance of sp 3 bonds with diamond phase and less for SS shows graphitization effect with dominant sp 2 bonds. It reveals the difference in local microstructure of carbon deposits leading to variation in contact angle and hardness, which is ascribed to difference in the packing density of carbon films, as observed also by Raman.

  15. Experimental study of contamination by inhalation of radioactive iodine aerosols. Biological balance

    International Nuclear Information System (INIS)

    Marble, G.

    1968-01-01

    Several articles have been published concerning research into contamination produced by inhalation of radioactive iodine aerosols in monkeys. Results dealing with the biological balance of this contamination are presented and discussed in this report. (author) [fr

  16. Cow Dung Ingestion and Inhalation Dependence: A Case Report

    Science.gov (United States)

    Khairkar, Praveen; Tiple, Prashant; Bang, Govind

    2009-01-01

    Although abuse of several unusual inhalants had been documented, addiction to cow dung fumes or their ashes has not been reported in medical literature as yet. We are reporting a case of cow dung dependence in ingestion and inhalational form.

  17. The response of liquid-filled pipes to vapour collapse

    International Nuclear Information System (INIS)

    Tijsseling, A.S.; Fan, D.

    1991-01-01

    The collapse of vapour cavities in liquid is usually accompanied with almost instantaneous pressure rises. These pressure rises impose severe loads on liquid-conveying pipes whenever the cavities become sufficiently large. Due to the impact nature of loadings, movement of the pipe walls can be expected. Tests are performed in a water-filled closed pipe suspended by thin steel wires. Vaporous cavities are induced in the liquid by hitting the pipe axially by a steel rod. The volume of the cavities can be varied by changing the initial pressure of the water. The developing and collapsing of cavities in the liquid is inferred from pressure measurements. Strain gauges and a laser Doppler vibrometer are used to record the response of the pipe to these pressures. The test results are compared with predictions from a numerical model. The model describes 1) axial stress wave propagations in the pipe and 2) water hammer and cavitation phenomena in the liquid. Pipe and liquid interact via 1) the radial expansion and contraction of the pipe wall and 2) the closed ends of the pipe, where large vapour cavities may develop. (author)

  18. Self-reported osteoporosis prevention in inhaled corticosteroid users in community pharmacy setting

    Directory of Open Access Journals (Sweden)

    Valerie Chan

    2015-05-01

    Full Text Available Objectives: The use of inhaled corticosteroids is the standard maintenance therapy in asthma therapy and as adjunct therapy in moderate to severe chronic obstructive pulmonary disease. A dose-related increase in fracture risk is associated with inhaled corticosteroid use; there is an inverse relationship between bone mineral density and duration and cumulative dose of inhaled corticosteroid. Adequate intake of calcium and vitamin D are cornerstones of osteoporosis prevention. The objectives are to assess whether the proportion of patients receiving inhaled corticosteroids are taking calcium and vitamin D; the association between long-term inhaled corticosteroid use and abnormal bone mineral density or fractures; and how many qualified patients received bone mineral density scans. Methods: Patients who filled a prescription for inhaled corticosteroids at selected community pharmacies across Alberta were recruited for a survey of their osteoporosis prevention activities. Results: A total of 256 patients from 12 community pharmacies were included. The average age was 60 ± 17.4 years with 65% female. There were 21%, 51%, and 28% of patients on high, medium, and low dose inhaled corticosteroids, respectively. Only 17% of patients >50 years old received recommended calcium and vitamin D supplementation and 87 (73% of the qualified patients received bone mineral density scan. Conclusion: Osteoporosis prevention in inhaled corticosteroid users is currently poorly addressed. More promotion is needed to raise pharmacist awareness of the risks of inhaled corticosteroids.

  19. The investigation on the vapour liquid phase equilibrium of (ammonia + 1,1,1,2-tetrafluoroethane) system over the temperatures ranging from (243.150 to 283.150) K

    International Nuclear Information System (INIS)

    Zhao, Yanxing; Dong, Xueqiang; Zhong, Quan; Gong, Maoqiong; Shen, Jun

    2017-01-01

    Highlights: • The vapour liquid equilibrium for ammonia + 1,1,1,2-tetrafluoroethane system was studied. • Measurements were based on vapour phase single recirculation method. • A positive azeotropic behaviour was exhibited at the experimental temperature range. - Abstract: To blend ammonia with some hydrofluorocarbons may give these mixed refrigerants lower flammability and global warming potential. In this paper, the isothermal vapour liquid equilibrium (VLE) of (ammonia + 1,1,1,2-tetrafluoroethane) system at temperatures ranging from (243.150 to 283.150) K are presented. Two models were employed to regress the experimental VLE results, namely the Peng–Robinson (PR) equation of state with the simple van der waals (VDW) mixing rule; the Peng–Robinson equation of state combined non-random two-liquid (NRTL) activity coefficient model with the modified Huron-Vidal one-order (MHV1) mixing rule. The maximum average absolute relative deviation of pressure (AARDp) and average absolute deviation of the vapour phase mole fraction (AADy) for PR-VDW are 0.56% and 0.010, respectively, while the maximum AARDp and AADy for PR-MHV1-NRTL are 0.27% and 0.014, respectively. Positive azeotropic behaviour was exhibited at each temperature investigated.

  20. Lung Deposition And Biological Effects Of Inhaled Radon Progenies

    International Nuclear Information System (INIS)

    Balashazy, I.; Farkas, A.; Szoke, I.; Moustafa, M.; Kudela, G.

    2010-01-01

    Inhaled radon progenies provide more than the half of natural radiation exposure. There is increasing evidence that the cellular distribution of radiation burden is an important factor regarding the biological response to ionisation radiation, thus, one of our tasks was the characterisation of the distribution of cellular exposure. Histological studies of former uranium miners presented strong correlation between primer deposition hot spots and neoplastic lesions. Most of these lesions were located along the carinal regions of the large bronchial airways. In the present work, computational fluid dynamics (CFD) approaches have been applied to simulate the deposition distribution of inhaled radon progenies along central human airways. The geometry and the cellular structure of epithelial lung tissue were numerically reconstructed based on anatomical and histological data. Single and multiple ha-hit and cellular dose distributions have been computed applying Monte Carlo modelling techniques at different breathing conditions. Figure 1. Deposition enhancement factor (EF) of inhaled radon progenies on a central airway bifurcation in airway generations 4-5 during light physical activity breathing condition. Size of scanning surface element is a 45μm side triangle. Left panel: EF max=1400,Dp=200 nm (attached). Right panel: EF max1290, Dp= 1 nm (unattached). Values of local per average deposition densities, that is, enhancement factors (Figure 1), hit probabilities and doses may be up to two-three orders of magnitude higher in the deposition hot spots than the average values. Dose calculations revealed that some cell clusters may receive high doses even at low exposure conditions. Applying the model to different radiation exposure conditions useful relations can be received regarding the linear-non threshold hypothesis

  1. Detection of quadrupole relaxation in an optically pumped cesium vapour

    Energy Technology Data Exchange (ETDEWEB)

    Bernabeu, E; Tornos, J

    1985-10-01

    The relaxation of quadrupole orientation induced by means of optical pumping in a cesium vapour is experimentally studied, and the results are compared to the theoretical predictions. The optical detection process of this type of orientation is also discussed as a function of the polarization and spectral profile of the detection light.

  2. Chemical vapour transport of pyrite (FeS 2) with halogen (Cl, Br, I)

    Science.gov (United States)

    Fiechter, S.; Mai, J.; Ennaoui, A.; Szacki, W.

    1986-12-01

    A systematic study of chemical vapour transport (CVT) of pyrite with halogen, hydrogen halides and ammonium halides as transporting agents has shown that the transport with chlorine and bromine in a temperature gradient Δ T = 920-820 K yields the highest transport rates (˜6 mg/h) with crystals up to 5 mm edge length. Computing thermochemical equilibria and flux functions in the system Fe-S-Hal (Hal = Cl, Br, I) it has been confirmed that the transport velocity of pyrite is limited by the concentration of FeHal 2 in the vapour phase, the equilibrium position between FeHal 2(g) and FeHal 3(g) and the flux directions of the iron gas species.

  3. Can painted glass felt or glass fibre cloth be used as vapour barrier?

    DEFF Research Database (Denmark)

    El-Khattam, Amira; Andersen, Mie Them; Hansen, Kurt Kielsgaard

    2014-01-01

    In most Nordic homes the interior surfaces of walls and ceilings have some kind of surface treatment for aesthetical reasons. The treatments can for example be glass felt or glass fibre cloth which are painted afterwards. To evaluate the hygrothermal performance of walls and ceilings...... treatments. The surface treatments were glass felt or glass fibre cloth with different types of paints or just paint. The paint types were acrylic paint and silicate paint. The results show that the paint type has high influence on the water vapour resistance while the underlay i.e. glass felt or glass fibre...... acrylic paint on glass felt or glass fibre cloth cannot be used instead of a vapour barrier....

  4. Identification of inhaler technique errors with a routine procedure in Portuguese community pharmacy

    Directory of Open Access Journals (Sweden)

    Castel-Branco MM

    2017-12-01

    Full Text Available Background: A correct selection of drugs prescribed, but also the choice of the appropriate inhaler device, is crucial for the control of respiratory diseases. Objective: To evaluate the inhaler technique and identify potential errors of patients when treated with inhalers by testing a routinary procedure to be implemented in any community pharmacy. Methods: Adults with asthma/COPD and under inhalation therapy were invited to demonstrate how they use their inhalers. After direct observation it was registered whether all the sequential steps included in the summary of product characteristics (SmPC were performed. Results: The study involved 67 patients from 4 community pharmacies (Portugal central region: 34 (50.7% males, 65.4 (SD=18.28 years old, 42 (62.7% with COPD, and 23 (34.3% using more than one inhaler. The 67 patients used 95 inhalers, comprising: 57 (60.0% multiple dose DPI (dry powder inhalers, 18 (18.9% single dose DPI, 16 (16.8% pMDI (pressurized metered dose inhalers, 2 (2.1% pMDI+spacer and 2 (2.1% SMI (soft mist inhalers. No errors were made only by 9 (13.4% patients. In the 75 DPIs techniques, the most frequent errors were ‘no previous forced expiration’ (46=61.3% and ‘no 10s apnea after inhalation’ (51=68.0%; in the 16 pMDIs techniques common errors were ‘lack of hand-lung coordination’ (7=43.8 %, ‘no previous forced exhalation’ (8=50.0% and ‘no apnea after inhalation’ (10=62.5%. After inhaling from 56 devices containing corticosteroids, 34 (60.7% of the patients did not wash their mouth. Conclusion: The study demonstrated the possibility of performing this procedure routinely in Portuguese community pharmacies and also its utility, since 58 (87% of patients had at least one error during the inhalers use.

  5. Detection of the contamination of air by tritiated water vapour around the reactor EL3

    International Nuclear Information System (INIS)

    Lebouleux, P.; Ardellier, A.; Valero, S.

    1968-01-01

    The authors describe the apparatus used for the detection of the tritiated water vapour contamination in the air around the reactor EL 3. The apparatus consists of two air-circulation ionisation chambers; the air in one of these is dried by passage through a silica-gel column. By carrying out a differential measurement of the ionization currents, it is possible to measure the tritiated water vapour concentration. A theoretical study of the response of the chambers is carried out for two types of emission of the tritiated water vapour: continuous, or in bursts. The experimental work comprises: calibration in the measurement range employed; study of the selectivity for other active gases; study of typical accidents; the interpretation of the results in the case of discontinuous emission, taking into account the desorption from the walls of the measurement chamber, a phenomenon which is observed during the emptying process. The authors give finally actual examples of how to use the results. The apparatus built makes it possible to detect, in less than ten minutes, contamination by tritiated water vapour in the presence of other active gases, in a measurement range of between 3 and 2200 MPC, and with an accuracy of about 25 per cent. A transposition to calculations of the risk to workers should be made with the utmost caution; an envelope of this risk can be drawn up more or less accurately depending on particular cases. (authors) [fr

  6. Dispersion of gold nanoclusters in TMBPA-polycarbonate by a combination of thermal embedding and vapour-induced crystallization

    International Nuclear Information System (INIS)

    Kruse, J; Dolgner, K; Greve, H; Zaporojtchenko, V; Faupel, F

    2006-01-01

    Gold nanoclusters can be dispersed into the surface of a bisphenol-A polycarbonate film by acetone vapour induced crystallization, an effect which has been demonstrated in a previous publication of our group. Gold nanoclusters were deposited by physical vapour deposition on an amorphous thin film of polycarbonate. After vapour induced crystallization these clusters were detected by depth profiling to be embedded into the surface, with a concentration maximum in a depth of approximately 100 nm. In this work, we replaced the BPA by the modified tetramethyl bisphenol-A polycarbonate, which shows a slower crystallization kinetics. A strong enhancement of the dispersion depth has been achieved by thermal pre-embedding of the clusters into the surface. Surface analysis by means of atomic force microscopy reflects the rearrangement of polymer material in the course of crystallization

  7. Comparison of aerosol inhalation lung images using BARC and other nebulizers

    International Nuclear Information System (INIS)

    Isawa, Toyoharu; Teshima, Takeo; Anazawa, Yoshiki; Miki, Makoto

    1994-01-01

    cases including one normal subject are presented briefly in the following. The size of aerosol definitely determines the site of deposition of inhaled aerosol in the lungs. The smaller the aerosol size, the better the penetration of inhaled aerosol in the lung periphery. This fact was demonstrated not only qualitatively as in this study but also quantitatively by calculating several parameters like alveolar deposition ratio, Xmax, Xmean, standard deviation, skewness and kurtosis of the count profile in the lung slice of the the right mid-lung. Our BARC nebulizer produced a very good-sized aerosol to be used in the daily practice. Technegas producing far smaller particles in size has characteristics of both aerosol particle and gas. Aerosol inhalation lung images are indispensable means to studying functional aspects of the lungs from the airway side and help interpret the perfusion counterpart of the lungs. Because smaller particles better penetrate the lung periphery, the aerosol inhalation lung images obtained by inhaling smaller aerosol particles would give a better idea of actual ventilatory status in the lungs. From the practical point of view aerosol of less than 2-3 micron in size would be well applicable to the evaluation of the ventilatory status in the lungs. Aerosol deposition patterns indicate the regional airway physiology as well as the ventilatory status of the lungs

  8. [Inhaled treatments in cystic fibrosis: what's new in 2013?].

    Science.gov (United States)

    Dubus, J-C; Bassinet, L; Chedevergne, F; Delaisi, B; Desmazes-Dufeu, N; Reychler, G; Vecellio, L

    2014-04-01

    In the past few years some new inhaled drugs and inhalation devices have been proposed for the treatment of cystic fibrosis. Breath-controlled nebulizers allow increased pulmonary deposition, with a lower variability and a shorter delivery time. The new dry powder formulations of tobramycin, colistine and mannitol require a change in the inhalation technique which must be slow and deep. In the field of the inhaled mucolytic drugs, hypertonic saline and mannitol have an indication in some patients. With regard to antibiotics, dry-powder tobramycin and colistine can be substituted for the same drug delivered by nebulization. Nebulized aztreonam needs more studies to determine its place. These new treatments represent a definite advance for cystic fibrosis patients and need to be known by all practitioners. Their position in our therapeutic arsenal remains to be accurately defined. Copyright © 2013 SPLF. Published by Elsevier Masson SAS. All rights reserved.

  9. Acute Inhalation Exposure to Titanium Ethanolate as a Possible Cause of Metal Fume Fever

    Directory of Open Access Journals (Sweden)

    M Ahmadimanesh

    2014-04-01

    Full Text Available Occupational inhalation exposure to noxious agents is not uncommon. Herein, we present a 26-year-old male student who had accidental acute inhalation exposure to a large quantity of titanium ethanolate and hydrogen chloride in chemistry lab. He was referred to the emergency department of our hospital with low-grade fever, dyspnea, headache, fatigue and myalgia. After 24 hrs of symptomatic treatment (oxygen therapy and acetaminophen, the fever was subsided and the patient discharged home in a good clinical condition. The presented symptoms could be interpreted as a form of metal fume fever. It can therefore be concluded that organo-metallic compound of titanium metal may have the potential to produce metal fume fever in human.

  10. Strong low-pass filtering effects on water vapour flux measurements with closed-path eddy correlation systems

    DEFF Research Database (Denmark)

    Ibrom, Andreas; Dellwik, Ebba; Flyvbjerg, Henrik K.

    2007-01-01

    datasets for this substantial measurement error. In contrast to earlier studies, a large number of spectra and raw data have been used in the analysis to define the low-pass filtering characteristic of the EC system. This revealed that the cut-off frequency of the closed-path EC system for water vapour......Turbulent water vapour fluxes measured with closed-path eddy correlation (EC) systems are unintentionally low-pass filtered by the system in a manner that varies with environmental conditions. Why and how is described here. So is the practical method that systematically corrects long-term flux...... concentration measurements decreases exponentially with increasing relative humidity. After correction for this unintended filtering, the fluxes are consistent with CO2 and H2O fluxes that were measured with an open-path sensor at the same time. The correction of water vapour flux measurements over a Beech...

  11. The early summertime Saharan heat low: sensitivity of the radiation budget and atmospheric heating to water vapour and dust aerosol

    Science.gov (United States)

    Alamirew, Netsanet K.; Todd, Martin C.; Ryder, Claire L.; Marsham, John H.; Wang, Yi

    2018-01-01

    The Saharan heat low (SHL) is a key component of the west African climate system and an important driver of the west African monsoon across a range of timescales of variability. The physical mechanisms driving the variability in the SHL remain uncertain, although water vapour has been implicated as of primary importance. Here, we quantify the independent effects of variability in dust and water vapour on the radiation budget and atmospheric heating of the region using a radiative transfer model configured with observational input data from the Fennec field campaign at the location of Bordj Badji Mokhtar (BBM) in southern Algeria (21.4° N, 0.9° E), close to the SHL core for June 2011. Overall, we find dust aerosol and water vapour to be of similar importance in driving variability in the top-of-atmosphere (TOA) radiation budget and therefore the column-integrated heating over the SHL (˜ 7 W m-2 per standard deviation of dust aerosol optical depth - AOD). As such, we infer that SHL intensity is likely to be similarly enhanced by the effects of dust and water vapour surge events. However, the details of the processes differ. Dust generates substantial radiative cooling at the surface (˜ 11 W m-2 per standard deviation of dust AOD), presumably leading to reduced sensible heat flux in the boundary layer, which is more than compensated by direct radiative heating from shortwave (SW) absorption by dust in the dusty boundary layer. In contrast, water vapour invokes a radiative warming at the surface of ˜ 6 W m-2 per standard deviation of column-integrated water vapour in kg m-2. Net effects involve a pronounced net atmospheric radiative convergence with heating rates on average of 0.5 K day-1 and up to 6 K day-1 during synoptic/mesoscale dust events from monsoon surges and convective cold-pool outflows (haboobs). On this basis, we make inferences on the processes driving variability in the SHL associated with radiative and advective heating/cooling. Depending on the

  12. Numerical Analysis of Flow and Heat Transfer Characteristics of CO2 at Vapour and Supercritical Phases in Micro-Channels

    Directory of Open Access Journals (Sweden)

    Rao N.T.

    2016-01-01

    Full Text Available Supercritical carbon dioxide (CO2 has special thermal properties with better heat transfer and flow characteristics. Due to this reason, supercritical CO2 is being used recently in air-condition and refrigeration systems to replace non environmental friendly refrigerants. Even though many researches have been done, there are not many literatures for heat transfer and flow characteristics of supercritical CO2. Therefore, the main purpose of this study is to develop flow and heat transfer CFD models on two different phases; vapour and supercritical of CO2 to investigate the heat transfer characteristics and pressure drop in micro-channels. CO2 is considered to be in different phases with different flow pressures but at same temperature. For the simulation, the CO2 flow was assumed to be turbulent, nonisothermal and Newtonian. The numerical results for both phases are compared. From the numerical analysis, for both vapour and supercritical phases, the heat energy from CO2 gas transferred to water to attain thermal equilibrium. The temperature of CO2 at vapour phase decreased 1.78% compared to supercritical phase, which decreased for 0.56% from the inlet temperature. There was a drastic increase of 72% for average Nu when the phase changed from vapour to supercritical. The average Nu decreased rapidly about 41% after total pressure of 9.0 MPa. Pressure drop (ΔP increased together with Reynolds number (Re for vapour and supercritical phases. When the phase changed from vapour to supercritical, ΔP was increased about 26%. The results obtained from this study can provide information for further investigations on supercritical CO2.

  13. Mechanisms of action of inhaled fibers, particles and nanoparticles in lung and cardiovascular diseases

    Directory of Open Access Journals (Sweden)

    Donaldson Kenneth

    2007-05-01

    Full Text Available Abstract Background A symposium on the mechanisms of action of inhaled airborne particulate matter (PM, pathogenic particles and fibers such as silica and asbestos, and nanomaterials, defined as synthetic particles or fibers less than 100 nm in diameter, was held on October 27 and 28, 2005, at the Environmental Protection Agency (EPA Conference Center in Research Triangle Park, North Carolina. The meeting was the eighth in a series of transatlantic conferences first held in Penarth, Wales, at the Medical Research Council Pneumoconiosis Unit (1979, that have fostered long-standing collaborations between researchers in the fields of mineralogy, cell and molecular biology, pathology, toxicology, and environmental/occupational health. Results The goal of this meeting, which was largely supported by a conference grant from the NHLBI, was to assemble a group of clinical and basic research scientists who presented and discussed new data on the mechanistic effects of inhaled particulates on the onset and development of morbidity and mortality in the lung and cardiovascular system. Another outcome of the meeting was the elucidation of a number of host susceptibility factors implicated in adverse health effects associated with inhaled pathogenic particulates. Conclusion New models and data presented supported the paradigm that both genetic and environmental (and occupational factors affect disease outcomes from inhaled particulates as well as cardiopulmonary responses. These future studies are encouraged to allow the design of appropriate strategies for prevention and treatment of particulate-associated morbidity and mortality, especially in susceptible populations.

  14. Roughness and compressive strength of FDM 3D printed specimens affected by acetone vapour treatment

    Science.gov (United States)

    Beniak, Juraj; Križan, Peter; Šooš, Ľubomír; Matúš, Miloš

    2018-01-01

    Rapid Prototyping technologies are the fastest growing technologies in the manufacturing of components and parts. There are many techniques which can be used with different materials and different purposes of produced part. Gradually, Rapid Prototyping systems have grown into Additive Manufacturing, because technology expansion brings faster production, improved manufactured components, and expanded palette of used materials. So now this techniques are also used for regular production of special parts, where is usual change of part design, where is necessary to produce variety of different designs and shapes. The following article deals with Fused Deposition Modelling (FDM) technology, the core of which is the manufacture models and components from thermoplastic polymers by deposition single fibres of semi-molten plastic material layer by layer. The article focuses on the results of research for testing of manufactured specimens by FDM technology. Components are modified by acetone vapour for surface smoothing. The purpose is to point out how the additional specimen treatment influence the strength properties. Presented paper shows realized experiments and measurements of compressive force on specimens and surface roughness which are influenced by acetone vapour treatment.

  15. Inhalation of nanoplatelets - Theoretical deposition simulations.

    Science.gov (United States)

    Sturm, Robert

    2017-12-01

    Primary objective of the contribution was the theoretical prediction of nanoplatelet deposition in the human respiratory tract. Modeling was founded on the hypothetical inhalation of graphene nanoplatelets (GNP) measuring 0.01 and 0.1μm in thickness and adopting a projected area diameter of 1-30μm. Particle uptake was assumed to take place with inhalation flow rates of 250, 500, 750, and 1000cm 3 s -1 , respectively. For an appropriate description of pulmonary particle behavior, transport of GNP in a stochastic lung structure and deposition formulae based on analytical and numerical studies were presupposed. The results obtained from the theoretical approach clearly demonstrate that GNP with a thickness of 0.01μm deposit in the respiratory tract by 20-50%, whereas GNP with a thickness of 0.1μm exhibit a deposition of 20-90%. Larger platelets deposit with higher probability than small ones. Increase of inhalation flow rate is accompanied by decreased deposition in the case of thin GNP, whilst thicker GNP are preferably accumulated in the extrathoracic region. Generation-specific deposition ranges from 0.05 to 7% (0.01μm) and from 0.05 to 9%, with maximum values being obtained in airway generation 20. In proximal airway generations (0-10), deposition is increased with inhalation flow rate, whereas in intermediate to distal generations a reverse effect may be observed. Health consequences of GNP deposition in different lung compartments are subjected to an intense debate. Copyright © 2017. Published by Elsevier GmbH.

  16. Vapour pressures and heat capacity measurements on the C7-C9 secondary aliphatic alcohols

    International Nuclear Information System (INIS)

    Verevkin, Sergey P.; Schick, Christoph

    2007-01-01

    Molar enthalpies of vaporization of secondary C 7 -C 9 alkanols were obtained from the temperature dependence of the vapour pressure measured by the transpiration method. The measured data sets were checked for internal consistency successfully. A large number of the primary experimental results on temperature dependences of vapour pressures of secondary alcohols have been collected from the literature and have been treated uniform in order to derive their vaporization enthalpies at the reference temperature 298.15 K. This collection, together with our experimental results, have helped to ascertain the database for branched aliphatic alcohols

  17. Effects of pulmonary inhalation on hyperpolarized krypton-83 magnetic resonance T1 relaxation.

    Science.gov (United States)

    Stupic, K F; Elkins, N D; Pavlovskaya, G E; Repine, J E; Meersmann, T

    2011-07-07

    The (83)Kr magnetic resonance (MR) relaxation time T(1) of krypton gas in contact with model surfaces was previously found to be highly sensitive to surface composition, surface-to-volume ratio, and surface temperature. The work presented here explored aspects of pulmonary (83)Kr T(1) relaxation measurements in excised lungs from healthy rats using hyperpolarized (hp) (83)Kr with approximately 4.4% spin polarization. MR spectroscopy without spatial resolution was applied to the ex vivo lungs that actively inhale hp (83)Kr through a custom designed ventilation system. Various inhalation schemes were devised to study the influence of anatomical dead space upon the measured (83)Kr T(1) relaxation times. The longitudinal (83)Kr relaxation times in the distal airways and the respiratory zones were independent of the lung inhalation volume, with T(1) = 1.3 s and T(1) = 1.0 s, depending only on the applied inhalation scheme. The obtained data were highly reproducible between different specimens. Further, the (83)Kr T(1) relaxation times in excised lungs were unaffected by the presence of up to 40% oxygen in the hp gas mixture. The results support the possible importance of (83)Kr as a biomarker for evaluating lung function.

  18. A vapourized Δ(9)-tetrahydrocannabinol (Δ(9)-THC) delivery system part II: comparison of behavioural effects of pulmonary versus parenteral cannabinoid exposure in rodents.

    Science.gov (United States)

    Manwell, Laurie A; Ford, Brittany; Matthews, Brittany A; Heipel, Heather; Mallet, Paul E

    2014-01-01

    Studies of the rewarding and addictive properties of cannabinoids using rodents as animal models of human behaviour often fail to replicate findings from human studies. Animal studies typically employ parenteral routes of administration, whereas humans typically smoke cannabis, thus discrepancies may be related to different pharmacokinetics of parenteral and pulmonary routes of administration. Accordingly, a novel delivery system of vapourized Δ(9)-tetrahydrocannabinol (Δ(9)-THC) was developed and assessed for its pharmacokinetic, pharmacodynamic, and behavioural effects in rodents. A commercially available vapourizer was used to assess the effects of pulmonary (vapourized) administration of Δ(9)-THC and directly compared to parenteral (intraperitoneal, IP) administration of Δ(9)-THC. Sprague-Dawley rats were exposed to pure Δ(9)-THC vapour (1, 2, 5, 10, and 20mg/pad), using a Volcano® vapourizing device (Storz and Bickel, Germany) or IP-administered Δ(9)-THC (0.1, 0.3, 0.5, 1.0mg/kg), and drug effects on locomotor activity, food and water consumption, and cross-sensitization to morphine (5mg/kg) were measured. Vapourized Δ(9)-THC significantly increased feeding during the first hour following exposure, whereas IP-administered Δ(9)-THC failed to produce a reliable increase in feeding at all doses tested. Acute administration of 10mg of vapourized Δ(9)-THC induced a short-lasting stimulation in locomotor activity compared to control in the first of four hours of testing over 7days of repeated exposure; this chronic exposure to 10mg of vapourized Δ(9)-THC did not induce behavioural sensitization to morphine. These results suggest vapourized Δ(9)-THC administration produces behavioural effects qualitatively different from those induced by IP administration in rodents. Furthermore, vapourized Δ(9)-THC delivery in rodents may produce behavioural effects more comparable to those observed in humans. We conclude that some of the conflicting findings in animal

  19. Experiment of aerosol-release time for a novel automatic metered dose inhaler

    OpenAIRE

    Mingrong Zhang; Songhao Wang; Yu-Ching Yang

    2016-01-01

    The objective of this study was to evaluate the aerosol-release time in the development of a new automatic adapter for metered dose inhaler. With this device, regular manually operated metered dose inhalers become automatic. During the study, an inhalation simulator was designed and tested with the newly developed mechatronic system. By adjusting the volume and the pressure of the vacuum tank, most human inhalation waveforms were able to simulate. As an example, regular quick-deep and slow-de...

  20. 'Chasing the Dragon' - imaging of heroin inhalation leukoencephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Hagel, J. [Vancouver General Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada)]. E-mail: jeff_hagel@hotmail.com; Andrews, G. [UBC Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Vertinsky, T. [Vancouver General Hospital, Dept. of Radiology, Vancouver, British Columbia (Canada); Heran, M.K.S. [Vancouver General Hospital, Div. of Neuroradiology, Vancouver, British Columbia (Canada); Keogh, C. [BC Cancer Agency, Dept. of Radiology, Vancouver, British Columbia (Canada)

    2005-10-15

    'Chasing the dragon' refers to the inhalation of heroin pyrolysate vapors produced when the freebase form of heroin is heated. Inhalation of these vapors can result in a rare toxic spongiform leukoencephalopathy. The patients may progress through 3 defined clinical stages, with one-quarter reaching the terminal stage, which invariably leads to death. Imaging and, in particular, magnetic resonance imaging (MRI) demonstrates white matter findings that are felt to be specific for this entity and essential in its early diagnosis. We present the typical imaging findings in a pictorial essay format, using images taken from 9 patients who presented within an 18-month period at UBC-affiliated hospitals. These findings include low computed tomography (CT) attenuation and high T2 MRI signal most commonly in the posterior cerebral and cerebellar white matter, cerebellar peduncles, splenium of the corpus callosum, and posterior limb of the internal capsules. In addition, there is often selective, symmetric involvement of the corticospinal tract, the medial lemniscus, and the tractus solitarius. We also present the variable diffusion-weighted imaging arid apparent diffusion coefficient findings from 4 of our patients, which to our knowledge, have not been described in the literature. (author)

  1. Isothermal (vapour + liquid) equilibrium for binary mixtures of (tetrahydrofuran + 1,1,2,2-tetrachloroethane or tetrachloroethene) at nine temperatures

    International Nuclear Information System (INIS)

    Garriga, R.; Perez, P.; Gracia, M.

    2006-01-01

    Vapour pressures of (tetrahydrofuran + 1,1,2,2-tetrachloroethane, or tetrachloroethene) at nine temperatures between T = 283.15 K and T = 323.15 K were measured by a static method. The reduction of the vapour pressures data to obtain activity coefficients and excess molar Gibbs energies was carried out by fitting the vapour pressure data to the Redlich-Kister polynomial according to Barker's method. Excess molar volumes were also measured at T 298.15 K. A comparative analysis about the thermodynamic behaviour of both systems is performed, in terms of hydrogen bonding and electron-donor-acceptor interactions, as well as the resonance effect in tetrachloroethene

  2. Suffocation caused by plastic wrap covering the face combined with nitrous oxide inhalation.

    Science.gov (United States)

    Leth, Peter Mygind; Astrup, Birgitte Schmidt

    2017-09-01

    Suicide using a combination of a plastic bag over the head and inhalation of a non-irritating gas, such as helium, argon or nitrogen, has been reported in the literature. Here an unusual suicide method in a 17-year old man by suffocation from covering the face with household plastic wrap, combined with nitrous oxide inhalation, is presented. The case was reviewed based on police, autopsy and hospital reports. A PubMed search for scientific literature related to nitrous oxide abuse and suicide by suffocation was performed and our findings discussed in relation to the scientific literature found. The deceased was a 17-year old man who was found with the nose and mouth closed with a piece of kitchen plastic wrap. The plastic wrap had been removed prior to autopsy. Autopsy findings were suggestive of asphyxia, but were otherwise negative. Nitrous oxide was detected in the brain and lung tissue with headspace-gas chromatography-mass spectrometry (headspace-GCMS). The cause of death was assumed to be suffocation caused by plastic wrap covering the face, combined with nitrous oxide inhalation. Suicide was suspected because of a history of depression for several months. Nitrous oxide, also known as laughing gas, has a euphoric effect and is used as a recreational inhalant drug that can be purchased legally. Deaths caused by recreational nitrous oxide abuse are rare but may occur if used in combination with a plastic bag over the head. This is the first report of suicide by suffocation by external obstruction combined with nitrous oxide inhalation.

  3. Inhalation exposure to three-dimensional printer emissions stimulates acute hypertension and microvascular dysfunction.

    Science.gov (United States)

    Stefaniak, A B; LeBouf, R F; Duling, M G; Yi, J; Abukabda, A B; McBride, C R; Nurkiewicz, T R

    2017-11-15

    Fused deposition modeling (FDM™), or three-dimensional (3D) printing has become routine in industrial, occupational and domestic environments. We have recently reported that 3D printing emissions (3DPE) are complex mixtures, with a large ultrafine particulate matter component. Additionally, we and others have reported that inhalation of xenobiotic particles in this size range is associated with an array of cardiovascular dysfunctions. Sprague-Dawley rats were exposed to 3DPE aerosols via nose-only exposure for ~3h. Twenty-four hours later, intravital microscopy was performed to assess microvascular function in the spinotrapezius muscle. Endothelium-dependent and -independent arteriolar dilation were stimulated by local microiontophoresis of acetylcholine (ACh) and sodium nitroprusside (SNP). At the time of experiments, animals exposed to 3DPE inhalation presented with a mean arterial pressure of 125±4mmHg, and this was significantly higher than that for the sham-control group (94±3mmHg). Consistent with this pressor response in the 3DPE group, was an elevation of ~12% in resting arteriolar tone. Endothelium-dependent arteriolar dilation was significantly impaired after 3DPE inhalation across all iontophoretic ejection currents (0-27±15%, compared to sham-control: 15-120±21%). Endothelium-independent dilation was not affected by 3DPE inhalation. These alterations in peripheral microvascular resistance and reactivity are consistent with elevations in arterial pressure that follow 3DPE inhalation. Future studies must identify the specific toxicants generated by FDM™ that drive this acute pressor response. Copyright © 2017 Elsevier Inc. All rights reserved.

  4. Thermally decarboxylated sodium bicarbonate: Interactions with water vapour, calorimetric study

    Directory of Open Access Journals (Sweden)

    Natalia Volkova

    2013-06-01

    Full Text Available Isothermal titration calorimetry (ITC was used to study interactions between water vapour and the surface of thermally converted sodium bicarbonate (NaHCO3. The decarboxylation degree of the samples was varied from 3% to 35% and the humidity range was 54–100%. The obtained enthalpy values were all exothermic and showed a positive linear correlation with decarboxylation degrees for each humidity studied. The critical humidity, 75% (RHo, was determined as the inflection point on a plot of the mean−ΔHkJ/mole Na2CO3 against RH. Humidities above the critical humidity lead to complete surface dissolution. The water uptake (m was determined after each calorimetric experiment, complementing the enthalpy data. A mechanism of water vapour interaction with decarboxylated samples, including the formation of trona and Wegscheider’s salt on the bicarbonate surface is proposed for humidities below RHo. Keywords: Isothermal titration calorimetry, Sodium bicarbonate, Sodium carbonate, Trona salt, Wegscheider’s salt, Enthalpy, Relative humidity, Pyrolytic decarboxylation

  5. Determining the vapour pressures of plant volatiles from gas chromatographic retention data

    Czech Academy of Sciences Publication Activity Database

    Hoskovec, Michal; Grygarová, D.; Cvačka, Josef; Streinz, Ludvík; Zima, J.; Verevkin, S. P.; Koutek, Bohumír

    2005-01-01

    Roč. 1083, - (2005), s. 161-172 ISSN 0021-9673 Institutional research plan: CEZ:AV0Z4055905 Keywords : vapour pressure * thermodinamic parameters * plant volatiles Subject RIV: CC - Organic Chemistry Impact factor: 3.096, year: 2005

  6. Thinner inhalation effects on oxidative stress and DNA repair in a rat model of abuse.

    Science.gov (United States)

    Martínez-Alfaro, Minerva; Cárabez-Trejo, Alfonso; Gallegos-Corona, Marco-Antonio; Pedraza-Aboytes, Gustavo; Hernández-Chan, Nancy Georgina; Leo-Amador, Guillermo Enrique

    2010-04-01

    Humans can come into contact with thinner by occupational exposure or by intentional inhalation abuse. Numerous studies of workers for genotoxic effects of thinner exposure have yielded conflicting results, perhaps because co-exposure to variable other compounds cannot be avoided in workplace exposure studies. In contrast, there is no data concerning the genotoxic effects of intentional inhalation abuse. The aim of this project was to examine the genotoxic effects of thinner inhalation in an animal model of thinner abuse (rats exposed to 3000 ppm toluene, a high solvent concentration over a very short, 15 min time period, twice a day for 6 weeks). The data presented here provides evidence that thinner inhalation in our experimental conditions is able to induce weight loss, lung abnormalities and oxidative stress. This oxidative stress induces oxidative DNA damage that is not a characteristic feature of genotoxic damage. No significant difference in DNA damage and DNA repair (biomarkers of genotoxicity) in lymphocytes from thinner-treated and control rats was found. Lead treatment was used as a positive control in these assays. Finally, bone marrow was evaluated as a biomarker of cellular alteration associated with thinner inhalation. The observed absence of hemopoietic and genetic toxicity could be explained in part by the absence of benzene, the only carcinogenic component of thinner; however, benzene is no longer a common component of thinner. In conclusion, thinner did not cause genotoxic effects in an experimental model of intentional abuse despite the fact that thinner inhalation induces oxidative stress. (c) 2009 John Wiley & Sons, Ltd.

  7. Partitioning understory evapotranspiration in semi-arid ecosystems in Namibia using the isotopic composition of water vapour

    Science.gov (United States)

    de Blécourt, Marleen; Gaj, Marcel; Holtorf, Kim-Kirsten; Gröngröft, Alexander; Brokate, Ralph; Himmelsbach, Thomas; Eschenbach, Annette

    2016-04-01

    In dry environments with a sparse vegetation cover, understory evapotranspiration is a major component of the ecosystem water balance. Consequently, knowledge on the size of evapotranspiration fluxes and the driving factors is important for our understanding of the hydrological cycle. Understory evapotranspiration is made up of soil evaporation and plant transpiration. Soil evaporation can be measured directly from patches free of vegetation. However, when understory vegetation is present distinguishing between soil evaporation and plant transpiration is challenging. In this study, we aim to partition understory evapotranspiration based on an approach that combines the measurements of water-vapour fluxes using the closed chamber method with measurements of the isotopic composition of water vapour. The measurements were done in the framework of SASSCAL (Southern African Science Service Centre for Climate Change and Adaptive Land Management). The study sites were located in three different semi-arid ecosystems in Namibia: thornbush savanna, Baikiaea woodland and shrubland. At each site measurements were done under tree canopies as well as at unshaded areas between the canopies. We measured evaporation from the bare soil and evapotranspiration from patches covered with herbaceous species and shrubs using a transparent chamber connected with an infrared gas analyser (LI-8100A, LICOR Inc.). The stable isotope composition of water vapour inside the chamber and depth profiles of soil water stable isotopes were determined in-situ using a tuneable off-axis integrated cavity output spectroscope (OA-ICOS, Los Gatos Research, DLT 100). Xylem samples were extracted using the cryogenic vacuum extraction method and the isotopic composition of the extracted water was measured subsequently with a cavity-ring-down spectrometer (CRDS L2120-i, Picarro Inc.). We will present the quantified fluxes of understory evapotranspiration measured in the three different ecosystems, show the

  8. Energetics and dynamics of the neutralization of clustered ions in ammonia and water vapour

    International Nuclear Information System (INIS)

    Sennhauser, E.S.; Armstrong, D.A.

    1978-01-01

    The energetics and dynamics of neutralization reactions of clustered ions in ammonia and water vapour have been analysed. Neutralization rate coefficients were calculated for the ions in ammonia and for H + .(H 2 O)sub(n) combining with various clustered anions in water vapour up to densities of 4 x 10 19 molecule cm -3 at 390 K. In the case of ammonia, calculations were also performed at 298 K. For all systems, fractional contributions of the neutralization coefficients for specific cluster sizes to the overall coefficient αsub(eff) were evaluated. The computed value of αsub(eff) for NH 3 was in reasonable agreement with experimental data in the [NH 3 ] range 0.3 to 4 x 10 19 molecule cm -3 , and general trends stemming from the effects of increasing ion mass were pointed out. Calculations of energies of individual cluster sizes indicate possible neutralization reaction mechanisms. With some exception, proton transfer is the only possible path and no H atoms should be formed. This is in general agreement with literature results for water vapour at approximately 390 K and with [H 2 O] >= 2 x 10 x 10 19 molecule cm -3 . (author)

  9. Steam inhalation therapy: severe scalds as an adverse side effect

    Science.gov (United States)

    Baartmans, Martin; Kerkhof, Evelien; Vloemans, Jos; Dokter, Jan; Nijman, Susanne; Tibboel, Dick; Nieuwenhuis, Marianne

    2012-01-01

    Background Steam inhalation therapy is often recommended in the treatment of a common cold. However, it has no proven benefit and may in fact have serious adverse side effects in terms of burn injuries. Aim To quantify the human and economic costs of steam inhalation therapy in terms of burn injury. Design and setting A prospective database study of all patients admitted to the burn centres (Beverwijk, Groningen, Rotterdam) and the hospital emergency departments in the Netherlands. Method Number and extent of burn injuries as a result of steam inhalation therapy were analysed, as well as an approximation made of the direct costs for their medical treatment. Results Annually, on average three people are admitted to in one of the Dutch burn centres for burns resulting from steam inhalation therapy. Most victims were children, and they needed skin grafting more often than adults. The total direct medical costs for burn centre and emergency department treatment were €115 500 (£93 000), emotional costs are not reflected. Conclusion As steam inhalation therapy has no proven benefit and the number and extent of complications of this therapy in terms of burn injury are significant, especially in children, steam inhalation therapy should be considered a dangerous procedure and not recommended anymore in professional guidelines and patient brochures. PMID:22781995

  10. Influence of treatment with inhalable heroin on pulmonary function

    NARCIS (Netherlands)

    Buster, M. C. A.; van den Brink, W.; van Brussel, G. H. A.; van Ree, J. M.

    2011-01-01

    This study aims to asses the influence of inhalable heroin on pulmonary function in chronic heroin-dependent patients treated with inhalable heroin. Among 32 patients (all cigarette smokers), a spirometric test was conducted at baseline and after an average period of 10 months of treatment with

  11. Inhalable Ipratropium Bromide Particle Engineering with Multicriteria Optimization.

    Science.gov (United States)

    Vinjamuri, Bhavani Prasad; Haware, Rahul V; Stagner, William C

    2017-08-01

    Spray-dried ipratropium bromide (IPB) microspheres for oral inhalation were engineered using Quality by Design. The interrogation of material properties, process parameters, and critical product quality attributes interplay enabled rational product design. A 2 7-3 screening design exhibited the Maillard reaction between L-leucine (LL) and lactose at studied outlet temperatures (OT) >130°C. A response surface custom design was used in conjunction with multicriteria optimization to determine the operating design space to achieve inhalable microparticles. Statistically significant predictive models were developed for volume median diameter (p = 0.0001, adjusted R 2   = 0.9938), span (p = 0.0278, adjusted R 2   = 0.7912), yield (p = 0.0020, adjusted R 2   = 0.9320), and OT (p = 0.0082, adjusted R 2   = 0.8768). An independent verification batch confirmed the model's predictive capability. The prediction and actual values were in good agreement. Particle size and span were 3.32 ± 0.09 μm and 1.71 ± 0.18, which were 4.7 and 5.3% higher than the predicted values. The process yield was 50.3%, compared to the predicted value of 65.3%. The OT was 100°C versus the predicted value of 105°C. The label strength of IPB microparticles was 99.0 to 105.9% w/w suggesting that enrichment occurred during the spray-drying process. The present study can be utilized to initiate the design of the first commercial IPB dry powder inhaler.

  12. A review of the value of innovation in inhalers for COPD and asthma.

    Science.gov (United States)

    Virchow, Johann Christian; Akdis, Cezmi A; Darba, Josep; Dekhuijzen, Richard; Hartl, Sylvia; Kobelt, Gisela; Roger, Albert; Simoens, Steven; Toumi, Mondher; Woodhouse, Ben; Plich, Adam; Torvinen, Saku

    2015-01-01

    Appropriate use of inhaled therapies for asthma and chronic obstructive pulmonary disease (COPD) is critical to ensuring good patient outcomes, efficient use of healthcare resources and limiting the effects of high-morbidity. The appropriate choice of inhaler and active therapy, incorporating patient preferences, can help improve treatment adherence and long-term outcomes. Despite this, many current inhalers are non-intuitive to use, and require extensive training. In this review, an expert panel considers the evidence for the use of inhaler devices in management of COPD and asthma. The panel also evaluates the value of innovation in inhaler technologies, which optimise the use of existing molecules from a clinical, economic and societal perspective. The panel conclusion is that there remains a substantial unmet need in inhaler technology and that innovation in inhaler devices can provide real-world health benefits to patients. Furthermore, we recommend that these innovations should be supported by healthcare systems through appropriate pricing and reimbursement mechanisms.

  13. Plasma Assisted Chemical Vapour Deposition – Technological Design Of Functional Coatings

    Directory of Open Access Journals (Sweden)

    Januś M.

    2015-06-01

    Full Text Available Plasma Assisted Chemical Vapour Deposition (PA CVD method allows to deposit of homogeneous, well-adhesive coatings at lower temperature on different substrates. Plasmochemical treatment significantly impacts on physicochemical parameters of modified surfaces. In this study we present the overview of the possibilities of plasma processes for the deposition of diamond-like carbon coatings doped Si and/or N atoms on the Ti Grade2, aluminum-zinc alloy and polyetherketone substrate. Depending on the type of modified substrate had improved the corrosion properties including biocompatibility of titanium surface, increase of surface hardness with deposition of good adhesion and fine-grained coatings (in the case of Al-Zn alloy and improving of the wear resistance (in the case of PEEK substrate.

  14. SPATIO-TEMPORAL ESTIMATION OF INTEGRATED WATER VAPOUR OVER THE MALAYSIAN PENINSULA DURING MONSOON SEASON

    Directory of Open Access Journals (Sweden)

    S. Salihin

    2017-10-01

    Full Text Available This paper provides the precise information on spatial-temporal distribution of water vapour that was retrieved from Zenith Path Delay (ZPD which was estimated by Global Positioning System (GPS processing over the Malaysian Peninsular. A time series analysis of these ZPD and Integrated Water Vapor (IWV values was done to capture the characteristic on their seasonal variation during monsoon seasons. This study was found that the pattern and distribution of atmospheric water vapour over Malaysian Peninsular in whole four years periods were influenced by two inter-monsoon and two monsoon seasons which are First Inter-monsoon, Second Inter-monsoon, Southwest monsoon and Northeast monsoon.

  15. Microwave measurements of the absolute values of absorption by water vapour in the atmosphere.

    Science.gov (United States)

    Hogg, D C; Guiraud, F O

    1979-05-31

    MEASUREMENT of the absolute value of absorption by water vapour at microwave frequencies is difficult because the effect is so small. Far in the wings of the absorption lines, in the so-called 'windows' of the spectrum, it is especially difficult to achieve high accuracy in the free atmosphere. But it is in these windows that the behaviour of the absorption is important from both applied and scientific points of view. Satellite communications, remote sensing of the atmosphere, and radioastronomy, are all influenced by this behaviour. Measurements on an Earth-space path are reported here; the results indicate a nonlinear relationship between absorption and water-vapour content.

  16. Safety of an alkalinizing buffer designed for inhaled medications in humans.

    Science.gov (United States)

    Davis, Michael D; Walsh, Brian K; Dwyer, Scott T; Combs, Casey; Vehse, Nico; Paget-Brown, Alix; Pajewski, Thomas; Hunt, John F

    2013-07-01

    Airway acidification plays a role in disorders of the pulmonary tract. We hypothesized that the inhalation of alkalinized glycine buffer would measurably alkalinize the airways without compromising lung function or causing adverse events. We evaluated the safety of an inhaled alkaline glycine buffer in both healthy subjects and in subjects with stable obstructive airway disease. This work includes 2 open-label safety studies. The healthy controls were part of a phase 1 safety study of multiple inhalations of low-dose alkaline glycine buffer; nebulized saline was used as a comparator in 8 of the healthy controls. Subsequently, a phase 2 study in subjects with stable obstructive airway disease was completed using a single nebulized higher-dose strategy of the alkaline inhalation. We studied 20 non-smoking adults (10 healthy controls and 10 subjects with obstructive airway disease), both at baseline and after inhalation of alkaline buffer. We used spirometry and vital signs as markers of clinical safety. We used changes in fraction of exhaled nitric oxide (NO) and exhaled breath condensate (EBC) pH as surrogate markers of airway pH modification. Alkaline glycine inhalation was tolerated by all subjects in both studies, with no adverse effects on spirometric parameters or vital signs. Airway alkalinization was confirmed by a median increase in EBC pH of 0.235 pH units (IQR 0.56-0.03, P = .03) in subjects after inhalation of the higher-dose alkaline buffer (2.5 mL of 100 mmol/L glycine). Alkalinization of airway lining fluid is accomplished with inhalation of alkaline glycine buffer and causes no adverse effects on pulmonary function or vital signs.

  17. Systematic Review Protocol for the IRIS Chloroform Assessment (Inhalation) (Preliminary Assessment Materials)

    Science.gov (United States)

    In January 2018, EPA released the Systematic Review Protocol for the IRIS Chloroform Assessment (Inhalation). As part of developing a draft IRIS assessment, EPA presents a methods document, referred to as the protocol, for conducting a chemical-specific systematic revie...

  18. Accuracy and conservatism of vapour intrusion algorithms for contaminated land management

    NARCIS (Netherlands)

    Provoost, J.; Reijnders, L.; Bonders, J.

    2013-01-01

    This paper provides a view on the suitability of screening-level vapour intrusion (VI) algorithms for contaminated land management. It focuses on the accuracy and level of conservatism for a number of screening-level algorithms used for VI into buildings. The paper discusses the published evidence

  19. ANNEALING OF POLYCRYSTALLINE THIN FILM SILICON SOLAR CELLS IN WATER VAPOUR AT SUB-ATMOSPHERIC PRESSURES

    Directory of Open Access Journals (Sweden)

    Peter Pikna

    2014-10-01

    Full Text Available Thin film polycrystalline silicon (poly-Si solar cells were annealed in water vapour at pressures below atmospheric pressure. PN junction of the sample was contacted by measuring probes directly in the pressure chamber filled with steam during passivation. Suns-VOC method and a Lock-in detector were used to monitor an effect of water vapour to VOC of the solar cell during whole passivation process (in-situ. Tested temperature of the sample (55°C – 110°C was constant during the procedure. Open-circuit voltage of a solar cell at these temperatures is lower than at room temperature. Nevertheless, voltage response of the solar cell to the light flash used during Suns-VOC measurements was good observable. Temperature dependences for multicrystalline wafer-based and polycrystalline thin film solar cells were measured and compared. While no significant improvement of thin film poly-Si solar cell parameters by annealing in water vapour at under-atmospheric pressures was observed up to now, in-situ observation proved required sensitivity to changing VOC at elevated temperatures during the process.

  20. Statistical nature of cluster emission in nuclear liquid-vapour phase coexistence

    International Nuclear Information System (INIS)

    Ma, Y G; Han, D D; Shen, W Q; Cai, X Z; Chen, J G; He, Z J; Long, J L; Ma, G L; Wang, K; Wei, Y B; Yu, L P; Zhang, H Y; Zhong, C; Zhou, X F; Zhu, Z Y

    2004-01-01

    The emission of nuclear clusters is investigated within the framework of the isospin-dependent lattice gas model and the classical molecular dynamics model. It is found that the emission of an individual cluster which is heavier than proton is almost Poissonian except near the transition temperature at which the system is leaving the liquid-vapour phase coexistence and thermal scaling is observed by the linear Arrhenius plots which are made from the average multiplicity of each cluster versus the inverse of temperature in the liquid-vapour phase coexistence. The slopes of the Arrhenius plots, i.e. the 'emission barriers', are extracted as a function of the mass or charge number and fitted by the formula embodied with the contributions of the surface energy and Coulomb interaction. Good agreements are obtained in comparison with the data for low-energy conditional barriers. In addition, the possible influences of the source size, Coulomb interaction and 'freeze-out' density and related physical implications are discussed