Post-Decontamination Vapor Sampling and Analytical Test Methods
2015-08-12
is decontaminated that could pose an exposure hazard to unprotected personnel. The chemical contaminants may include chemical warfare agents (CWAs... decontamination process. Chemical contaminants can include chemical warfare agents (CWAs) or their simulants, nontraditional agents (NTAs), toxic industrial...a range of test articles from coupons, panels, and small fielded equipment items. 15. SUBJECT TERMS Vapor hazard; vapor sampling; chemical warfare
National Research Council Canada - National Science Library
Dutt, D. L; Turetsky, A. L; Brickhouse, M; Pfarr, J. W; McVey, I. F; Meilander, S. L; Janick, A. J; Schulte, S. L; Dallmier, A. W
2004-01-01
.... While many chemical decontamination methods, including aqueous hydrogen peroxide, have been used or are under development for direct application, few vaporous methods are being evaluated for decontamination efficacy (McDonnell, G. et al., 2002...
Vaporized Hydrogen Peroxide (VHP) Decontamination of VX, GD, and HD
National Research Council Canada - National Science Library
Wagner, George W; Sorrick, David C; Procell, Lawrence R; Hess, Zoe A; Brickhouse, Mark D; McVey, Iain F; Schwartz, Lewis I
2003-01-01
Vaporized Hydrogen Peroxide (VHP) has been utilized for more than a decade to sterilize clean rooms and pharmaceutical processing equipment and, quite recently, to decontaminate anthrax-ridden buildings...
2016-02-11
Vaporous Decontamination on Bacterial Spores and Other Biological Warfare Agents on Military-Relevant Surfaces 5a. CONTRACT NUMBER 5b. GRANT... DECONTAMINATION ON BACTERIAL SPORES AND OTHER BIOLOGICAL WARFARE AGENTS ON MILITARY-RELEVANT SURFACES Page Paragraph 1. SCOPE...surfaces before and after decontamination . The protocol in this TOP is based on the developed test methodologies from Edgewood Chemical Biological
A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent
International Nuclear Information System (INIS)
Waysbort, Daniel; McGarvey, David J.; Creasy, William R.; Morrissey, Kevin M.; Hendrickson, David M.; Durst, H. Dupont
2009-01-01
A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Green TM , has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO 4 -2 ) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t 1/2 ≤ 4 min), 1:10 for HD (t 1/2 1/2 < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD
Gon Ryu, Sam; Wan Lee, Hae
2015-01-01
The nerve agent, O-ethyl S-[2-(diisopropylamino)ethyl] methylphosphonothioate (VX) must be promptly eliminated following its release into the environment because it is extremely toxic, can cause death within a few minutes after exposure, acts through direct skin contact as well as inhalation, and persists in the environment for several weeks after release. A mixture of hydrogen peroxide vapor and ammonia gas was examined as a decontaminant for the removal of VX on solid surfaces at ambient temperature, and the reaction products were analyzed by gas chromatography-mass spectrometry (GC-MS) and nuclear magnetic resonance spectrometry (NMR). All the VX on glass wool filter disks was found to be eliminated after 2 h of exposure to the decontaminant mixtures, and the primary decomposition product was determined to be non-toxic ethyl methylphosphonic acid (EMPA); no toxic S-[2-(diisopropylamino)ethyl] methylphosphonothioic acid (EA-2192), which is usually produced in traditional basic hydrolysis systems, was found to be formed. However, other by-products, such as toxic O-ethyl S-vinyl methylphosphonothioate and (2-diisopropylaminoethyl) vinyl disulfide, were detected up to 150 min of exposure to the decontaminant mixture; these by-products disappeared after 3 h. The two detected vinyl byproducts were identified first in this study with the decontamination system of liquid VX on solid surfaces using a mixture of hydrogen peroxide vapor and ammonia gas. The detailed decontamination reaction networks of VX on solid surfaces produced by the mixture of hydrogen peroxide vapor and ammonia gas were suggested based on the reaction products. These findings suggest that the mixture of hydrogen peroxide vapor and ammonia gas investigated in this study is an efficient decontaminant mixture for the removal of VX on solid surfaces at ambient temperature despite the formation of a toxic by-product in the reaction process.
A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent
Energy Technology Data Exchange (ETDEWEB)
Waysbort, Daniel [Israel Institute for Biological Research, PO Box 19, Ness-Ziona 74100 (Israel); McGarvey, David J. [R and T Directorate, Edgewood Chemical and Biological Center (ECBC), Aberdeen Proving Ground-Edgewood Area, MD 21010 (United States)], E-mail: david.mcgarvey@us.army.mil; Creasy, William R.; Morrissey, Kevin M.; Hendrickson, David M. [SAIC, P.O. Box 68, Gunpowder Branch, Aberdeen Proving Ground, MD 21010 (United States); Durst, H. Dupont [R and T Directorate, Edgewood Chemical and Biological Center (ECBC), Aberdeen Proving Ground-Edgewood Area, MD 21010 (United States)
2009-01-30
A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Green{sup TM}, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO{sub 4}{sup -2}) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t{sub 1/2} {<=} 4 min), 1:10 for HD (t{sub 1/2} < 2 min with molybdate), and 1:10 for GD (t{sub 1/2} < 2 min). The vapor concentrations of GD above the dry sorbent and the sorbent with decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.
Vaporized Hydrogen Peroxide (VHP) Decontamination of a Section of a Boeing 747 Cabin
National Research Council Canada - National Science Library
Shaffstall, Robert M; Garner, Robert P; Bishop, Joshua; Cameron-Landis, Lora; Eddington, Donald L; Hau, Gwen; Spera, Shawn; Mielnik, Thaddeus; Thomas, James A
2006-01-01
The use of STERIS Corporation's Vaporized Hydrogen Peroxide (VHP)* technology as a potential biocide for aircraft decontamination was demonstrated in a cabin section of the Aircraft Environment Research Facility...
Coolant system decontamination
International Nuclear Information System (INIS)
Anstine, L.D.; James, D.B.; Melaika, E.A.; Peterson, J.P.
1981-01-01
An improved method for decontaminating the coolant system of water cooled nuclear power reactors and for regenerating the decontamination solution is described. A small amount of one or more weak-acid organic complexing agents is added to the reactor coolant, and the pH is adjusted to form a decontamination solution which is circulated throughout the coolant system to dissolve metal oxides from the interior surfaces and complex the resulting metal ions and radionuclide ions. The coolant containing the complexed metal ions and radionuclide ions is passed through a strong-base anion exchange resin bed which has been presaturated with a solution containing the complexing agents in the same ratio and having the same pH as the decontamination solution. As the decontamination solution passes through the resin bed, metal-complexed anions are exchanged for the metal-ion-free anions on the bed, while metal-ion-free anions in the solution pass through the bed, thus removing the metal ions and regenerating the decontamination solution. (author)
2006-06-01
over time. Ammonia gas is typically used to neutralise formaldehyde forming a white precipitate, hexamethylene- tetramine, which is then washed down...sulphite scrubbers DSTO-GD-0465 4 and a carbon bed to prevent any leakage of the ClO2 gas into the environment. The decontamination period (12...of ammonia gas) produces a broad-spectrum decontaminant against C agents [7]. However, initial studies have shown that the modified vaporous
A decontamination system for chemical weapons agents using a liquid solution on a solid sorbent.
Waysbort, Daniel; McGarvey, David J; Creasy, William R; Morrissey, Kevin M; Hendrickson, David M; Durst, H Dupont
2009-01-30
A decontamination system for chemical warfare agents was developed and tested that combines a liquid decontamination reagent solution with solid sorbent particles. The components have fewer safety and environmental concerns than traditional chlorine bleach-based products or highly caustic solutions. The liquid solution, based on Decon Greentrade mark, has hydrogen peroxide and a carbonate buffer as active ingredients. The best solid sorbents were found to be a copolymer of ethylene glycol dimethacrylate and n-lauryl methacrylate (Polytrap 6603 Adsorber); or an allyl methacrylate cross-linked polymer (Poly-Pore E200 Adsorber). These solids are human and environmentally friendly and are commonly used in cosmetics. The decontaminant system was tested for reactivity with pinacolyl methylphosphonofluoridate (Soman, GD), bis(2-chloroethyl)sulfide (Mustard, HD), and S-(2-diisopropylaminoethyl) O-ethyl methylphosphonothioate (VX) by using NMR Spectroscopy. Molybdate ion (MoO(4)(-2)) was added to the decontaminant to catalyze the oxidation of HD. The molybdate ion provided a color change from pink to white when the oxidizing capacity of the system was exhausted. The decontaminant was effective for ratios of agent to decontaminant of up to 1:50 for VX (t(1/2) decontamination solution were measured to show that the sorbent decreased the vapor concentration of GD. The E200 sorbent had the additional advantage of absorbing aqueous decontamination solution without the addition of an organic co-solvent such as isopropanol, but the rate depended strongly on mixing for HD.
The Use of Vaporous Hydrogen Peroxide for Building Decontamination Final Report CRADA No. TC-2053-02
Energy Technology Data Exchange (ETDEWEB)
Verce, M. F. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Schwartz, L. I. [Strategic Technology Enterprises, Inc., Mentor, OH (United States)
2017-09-08
This was a collaborative effort between LLNL and STE to investigate the use of vaporized hydrogen peroxide (VHP®) to decontaminate spore-contaminated heating, ventilation, and cooling (HV AC) systems in a trailer sized room. LLNL's effort under this CRADA was funded by DOE's Chemical and Biological National Security Program (CBNP), which later became part of Department of Homeland Security in 2004.
National Research Council Canada - National Science Library
Wagner, George; Procell, Larry; Sorrick, David; Maclver, Brian; Turetsky, Abe; Pfarr, Jerry; Dutt, Diane; Brickhouse, Mark
2004-01-01
Vaporous Hydrogen Peroxide (VHP) has been used for more than a decade to sterilize clean rooms and pharmaceutical processing equipment and, more recently, to decontaminate anthraxcontaminated buildings...
Full system decontamination. AREVAs experience in decontamination prior to decommissioning
International Nuclear Information System (INIS)
Topf, Christian
2010-01-01
Minimizing collective radiation exposure and producing free-release material are two of the highest priorities in the decommissioning of a Nuclear Power Plant (NPP). Full System Decontamination (FSD) is the most effective measure to reduce source term and remove oxide layer contamination within the plant systems. FSD is typically a decontamination of the primary coolant circuit and the auxiliary systems. In recent years AREVA NP has performed several FSDs in PWRs and BWRs prior to decommissioning by applying the proprietary CORD copyright family and AMDA copyright technology. Chemical Oxidation Reduction Decontamination or CORD represents the chemical decontamination process while AMDA stands for Automated Mobile Decontamination Appliance, AREVA NPs decontamination equipment. Described herein are the excellent results achieved for the FSDs applied at the German PWRs Stade in 2004 and Obrigheim in 2007 and for the FSDs performed at the Swedish BWRs, Barsebaeck Unit 1 in 2007 and Barsebaeck Unit 2 in 2008. All four FSDs were performed using the AREVA NP CORD family decontamination technology in combination with the AREVA NP decontamination equipment, AMDA. (orig.)
International Nuclear Information System (INIS)
Kanbe, Hiromi; Mayuzumi, Masami; Yoshiki, Sinya; Sema, Toru; Koyama, Hiroaki; Ono, Tetsuo; Nagae, Madoka; Takaoku, Yoshinobu; Hozumi, Masahiro.
1987-01-01
The small pilot facility of a cyclone type suspension incineration system of radioactive waste was set up in order to evaluate the decontamination efficiency of a high efficiency ceramic filter. The evaluation was made by use of 54 Mn, 59 Fe, 60 Co, 65 Zn and 137 Cs. 1. The decontamination factor by one line of ceramic filter for every species were over 10 5 . 2. The decontamination factor increased by one oder when water vapor exists in off-gas. The same tendency was also observed when iron dioxide existed at the incineration of cation exchange resin. (author)
Chemical decontamination method in nuclear facility system
International Nuclear Information System (INIS)
Takahashi, Ryota; Sakai, Hitoshi; Oka, Shigehiro.
1996-01-01
Pumps and valves in a closed recycling loop system incorporating materials to be chemically decontaminated are decomposed, a guide plate having the decomposed parts as an exit/inlet of a decontaminating liquid is formed, and a decontaminating liquid recycling loop comprising a recycling pump and a heater is connected to the guide plate. Decontaminating liquid from a decontaminating liquid storage tank is supplied to the decontaminating liquid recycling loop. With such constitutions, the decontaminating liquid is filled in the recycling closed loop system incorporating materials to be decontaminated, and the materials to be decontaminated are chemically decontaminated. The decontaminating liquid after the decontamination is discharged and flows, if necessary, in a recycling system channel for repeating supply and discharge. After the decontamination, the guide plate is removed and returned to the original recycling loop. When pipelines of a reactor recycling system are decontaminated, the amount of decontaminations can be decreased, and reforming construction for assembling the recycling loop again, which requires cutting for pipelines in the system is no more necessary. Accordingly, the amount of wastes can be decreased, and therefore, the decontamination operation is facilitated and radiation dose can be reduced. (T.M.)
Microwave-Based Water Decontamination System
Arndt, G. Dickey (Inventor); Byerly, Diane (Inventor); Sognier, Marguerite (Inventor); Dusl, John (Inventor)
2016-01-01
A system for decontaminating a medium. The system can include a medium having one or more contaminants disposed therein. The contaminants can be or include bacteria, fungi, parasites, viruses, and combinations thereof. A microwave energy radiation device can be positioned proximate the medium. The microwave energy radiation device can be adapted to generate a signal having a frequency from about 10 GHz to about 100 GHz. The signal can be adapted to kill one or more of the contaminants disposed within the medium while increasing a temperature of the medium by less than about 10 C.
Decontamination factors of ceramic filter in radioactive waste incineration system
International Nuclear Information System (INIS)
Kanbe, Hiromi; Mayuzumi, Masami; Ono, Tetsuo; Yoshiki, Shinya; Kouyama, Hiroaki; Nagae, Madoka; Sekiguchi, Ryosaku; Takaoku, Yoshinobu; Hozumi, Masahiro.
1987-01-01
A suspension-firing type radioactive waste incineration system is developed and cold demonstration testing of ceramic filters for the system are carried out. The incineration system, which is useful for a wide variety of waste materials, can serve to simplify the facilities and to reduce the costs for waste disposal. The incineration system can be used for drying-processing of concentrated waste liquids and disposal of flame resistant materials including ion exchange resins and rubber, as well as for ordinary combustible solid materials. An on-line backwash system is adopted to allow the ceramic filters to operate stably for a long period of time. For one-step filtering using the ceramic filter, the decontamination factor is greater than 10 5 for the processing of various wastes. In a practical situation, there exist vapor produced by the spray drier and the cladding in used ion exchange resin, which act to increase the decontamination performance of the ceramic filters to ensure safe operation. For the waste incineration system equipped with a waste gas processing apparatus consisting of a ceramic filter and HEPA filter, the overall decontamination factor is expected to be greater than 10 6 at portions down to the outlet of the ceramic filter and greater than 10 8 at portions down to the outlet of the HEPA filter. (Nogami, K.)
System for chemical decontamination of nuclear reactor primary systems
International Nuclear Information System (INIS)
Schlonski, J.S.; McGiure, M.F.; Corpora, G.J.
1992-01-01
This patent describes a method of chemically decontaminating a nuclear reactor primary system, having a residual heat removal system with one or more residual heat removal heat exchangers, each having an upstream and a downstream side, at or above ambient pressure. It comprises: injecting decontamination chemicals using an injection means; circulating the injected decontamination chemicals throughout the primary system; directing the circulated decontamination chemicals and process fluids to a means for removing suspended solids and dissolved materials after the circulated chemicals and process fluids have passed through the residual heat removal heat exchanger; decontaminating the process fluids; and feeding the decontaminated process fluids to the injection means. This patent also describes a chemical decontamination system for use at, or above, ambient pressure in a nuclear reactor primary system having a residual heat removal system. It comprises: means for injecting decontamination chemicals into the primary system; means for removing dissolved and suspended materials and decontamination chemicals from the primary system; one or more residual heat removal pumps; means located downstream of one of the residual heat removal heat exchangers; and a return line connecting the means
Full system decontamination feasibility studies
International Nuclear Information System (INIS)
Denault, R.P.; LeSurf, J.E.; Walschot, F.W.
1988-01-01
Many chemical decontaminations have been performed on subsystems in light water reactors (BWRs and PWRs) but none on the full system (including the fuel) of large, (>500 MWe) investor owned reactors. Full system decontaminations on pressure-tubed reactors have been shown to facilitate maintenance, inspection, repair and replacement of reactor components. Further advantages are increased reactor availability and plant life extension. A conceptual study has been performed for EPRI (for PWRs) and Commonwealth Edison Co (for BWRs) into the applicability and cost benefit of full system decontaminations (FSD). The joint study showed that FSDs in both PWRs and BWRs, with or without the fuel included in the decontamination, are feasible and cost beneficial provided a large amount of work is to be done following the decontamination. The large amounts of radioactive waste generated can be managed using current technologies. Considerable improvements in waste handling, and consequent cost savings, can be obtained if new techniques which are now reaching commercial application are used. (author)
Decontamination system study for the Tank Waste Retrieval System
International Nuclear Information System (INIS)
Reutzel, T.; Manhardt, J.
1994-05-01
This report summarizes the findings of the Idaho National Engineering Laboratory's decontamination study in support of the Tank Waste Retrieval System (TWRS) development program. Problems associated with waste stored in existing single shell tanks are discussed as well as the justification for the TWRS program. The TWRS requires a decontamination system. The subsystems of the TWRS are discussed, and a list of assumptions pertinent to the TWRS decontamination system were developed. This information was used to develop the functional and operational requirements of the TWRS decontamination system. The requirements were combined with a comprehensive review of currently available decontamination techniques to produced a set of evaluation criteria. The cleaning technologies and techniques were evaluated, and the CO 2 blasting decontamination technique was chosen as the best technology for the TWRS
Mechanical decontamination techniques for floor drain systems
International Nuclear Information System (INIS)
Palau, G.L.
1987-01-01
The unprecedented nature of cleanup activities at Three Mile Island Unit 2 (TMI-2) following the 1979 accident has necessitated the development of new techniques to deal with radiation and contamination in the plant. One of these problems was decontamination of floor drain systems, which had become highly contaminated with various forms of dirt and sludge containing high levels of fission products and fuel from the damaged reactor core. The bulk of this contamination is loosely adherent to the drain pipe walls; however, significant amounts of contamination have become incorporated into pipe wall oxide and corrosion layers and embedded in microscopic pits and fissures in the pipe wall material. The need to remove this contamination was recognized early in the TMI-2 cleanup effort. A program consisting of development and laboratory testing of floor drain decontamination techniques was undertaken early in the cleanup with support from the Electric Power Research Institute (EPRI). Based on this initial research, two techniques were judged to show promise for use at TMI-2: a rotating brush hone system and a high-pressure water mole nozzle system. Actual use of these devices to clean floor drains at TMI-2 has yielded mixed decontamination results. The decontamination effectiveness that has been obtained is highly dependent on the nature of the contamination in the drain pipe and the combination of decontamination techniques used
International Nuclear Information System (INIS)
Benavides, E.; Fajardo, M.
1992-01-01
Two decontamination processes have been developed to decontaminate the stainless steel components of nuclear power plants. The first process uses an underwater closed electropolishing system for the decontamination of large stainless steel surfaces in flooded systems without loss of electrolyte. Large underwater contaminated areas can be treated with an electropolishing head covering an area of 2 m 2 in one step. The decontamination factors achieved with this technique range between 100 and 1000. The second process consists in the decontamination of nuclear components using vibratory equipment with self-cleaning abrasives generating a minimum quantity of waste. This technique may reach contamination factors similar to those obtained with other abrasive methods (brush abrasion, abrasive blasting, etc...). The obtained decontamination factors range between 5 and 50. Only a small quantity of waste is generated, which is treated and reduced in volume by filtration and evaporation
Electrochemical decontamination system for actinide processing gloveboxes
International Nuclear Information System (INIS)
Wedman, D.E.; Lugo, J.L.; Ford, D.K.; Nelson, T.O.; Trujillo, V.L.; Martinez, H.E.
1998-03-01
An electrolytic decontamination technology has been developed and successfully demonstrated at Los Alamos National Laboratory (LANL) for the decontamination of actinide processing gloveboxes. The technique decontaminates the interior surfaces of stainless steel gloveboxes utilizing a process similar to electropolishing. The decontamination device is compact and transportable allowing it to be placed entirely within the glovebox line. In this way, decontamination does not require the operator to wear any additional personal protective equipment and there is no need for additional air handling or containment systems. Decontamination prior to glovebox decommissioning reduces the potential for worker exposure and environmental releases during the decommissioning, transport, and size reduction procedures which follow. The goal of this effort is to reduce contamination levels of alpha emitting nuclides for a resultant reduction in waste level category from High Level Transuranic (TRU) to low Specific Activity (LSA, less than or equal 100 nCi/g). This reduction in category results in a 95% reduction in disposal and disposition costs for the decontaminated gloveboxes. The resulting contamination levels following decontamination by this method are generally five orders of magnitude below the LSA specification. Additionally, the sodium sulfate based electrolyte utilized in the process is fully recyclable which results in the minimum of secondary waste. The process bas been implemented on seven gloveboxes within LANL's Plutonium Facility at Technical Area 55. Of these gloveboxes, two have been discarded as low level waste items and the remaining five have been reused
Ground-Based Global Positioning System (GPS) Meteorology Integrated Precipitable Water Vapor (IPW)
National Oceanic and Atmospheric Administration, Department of Commerce — The Ground-Based Global Positioning System (GPS) Meteorology Integrated Precipitable Water Vapor (IPW) data set measures atmospheric water vapor using ground-based...
International Nuclear Information System (INIS)
Betts, S.E.
1993-01-01
A program is currently in progress at Argonne National Laboratory to evaluate and develop evaporator technology for concentrating radioactive waste streams. By concentrating radioactive waste streams, disposal costs can be significantly reduced. To effectively reduce the volume of waste, the evaporator must achieve high decontamination factors so that the distillate is sufficiently free of radioactive material. One technology that shows a great deal of potential for this application is being developed by LICON, Inc. In this program, Argonne plans to apply LICON's evaporator designs to the processing of radioactive solutions. Concepts that need to be incorporated into the design of the evaporator include, criticality safety, remote operation and maintenance, and materials of construction. To design an effective process for concentrating waste streams, both solubility and vapor-liquid equilibrium data are needed. The key issue, however, is the high decontamination factors that have been demonstrated by this equipment. Two major contributions were made to this project. First, a literature survey was completed to obtain available solubility and vapor-liquid equilibrium data. Some vapor-liquid data necessary for the project but not available in the literature was obtained experimentally. Second, the decontamination factor for the evaporator was determined using neutron activation analysis (NAA)
Development of calculation system for decontamination effect, CDE
International Nuclear Information System (INIS)
Satoh, Daiki; Kojima, Kensuke; Oizumi, Akito; Matsuda, Norihiro; Kugo, Teruhiko; Sakamoto, Yukio; Endo, Akira; Okajima, Shigeaki
2012-08-01
Large amount of radionuclides had been discharged to environment in the accident of the Tokyo Electric Power Company Fukushima Daiichi Nuclear Power Plant caused by the 2011 off the Pacific coast of Tohoku Earthquake. The radionuclides deposited on the ground elevate dose rates in large area around the Fukushima site. For the reduction of the dose rate and recovery of the environment, decontamination based on a rational plan is an important and urgent subject. A computer software, named CDE (Calculation system for Decontamination Effect), has been developed to support planning the decontamination. CDE calculates the dose rates before the decontamination by using a database of dose contributions by radioactive cesium. The decontamination factor is utilized in the prediction of the dose rates after the decontamination, and dose rate reduction factor is evaluated to express the decontamination effect. The results are visualized on the image of a target zone with color map. In this paper, the overview of the software and the dose calculation method are reported. The comparison with the calculation results by a three-dimensional radiation transport code PHITS is also presented. In addition, the source code of the dose calculation program and user's manual of CDE are attached as appendices. (author)
Impact of decontamination on LWR radioactive waste treatment systems
International Nuclear Information System (INIS)
Hoenes, G.R.; Perrigo, L.D.; Divine, J.R.; Faust, L.G.
1979-01-01
Only at N-Reactor is there a means to accommodate radwaste produced during decontamination. The Dresden system is expected to be ready to accommodate such solutions by the summer of 1979. Solidification of the processed decontamination waste may be a significant problem. There is doubt that the materials in current radwaste treatment systems can handle chemicals from a concentrated process. The total storage volume, for concentrated decontamination, is not sufficient in existing radwaste treatment systems. Greater attention should be placed on designing reactors and radwaste treatment systems for decontamination. A means of handling waste material resulting from leaks in the primary system during the decontamination must be developed. On-site storage of solidified decontamination wastes may be a viable option, but license amendments will be necessary
Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems
International Nuclear Information System (INIS)
Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.
1978-08-01
Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentraion reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less
Modification and testing of the Sandia Laboratories Livermore tritium decontamination systems
International Nuclear Information System (INIS)
Gildea, P.D.; Birnbaum, H.G.; Wall, W.R.
1979-01-01
Sandia Laboratories, Livermore, has put into operation a new facility, the Tritium Research Laboratory. The laboratory incorporates containment and cleanup facilities such that any tritium accidentally released is captured rather than vented to the atmosphere. This containment is achieved with hermetically sealed glove boxes that are connected on demand by manifolds to two central decontamination systems called the Gas Purification System (GPS) and the Vacuum Effluent Recovery System (VERS). The primary function of the GPS is to remove tritium and tritiated water vapor from the glove box atmosphere. The primary function of the VERS is to decontaminate the gas exhausted from the glove box pressure control systems and vacuum pumps in the building before venting the gas to the stack. Both of these systems are designed to remove tritium to the few parts per billion range. Acceptance tests at the manufacturer's plant and preoperational testing at Livermore demonstrated that the systems met their design specifications. After preoperational testing the Gas Purification System was modified to enhance the safety of maintanance operations. Both the Gas Purification System and the Vacuum Effluent Recovery System were performance tested with tritium. Results show that concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass have been achieved for both systems at inlet concentrations of 1 ppM or less
Nuclear reactor vessel decontamination systems
International Nuclear Information System (INIS)
McGuire, P. J.
1985-01-01
There is disclosed in the present application, a decontamination system for reactor vessels. The system is operatable without entry by personnel into the contaminated vessel before the decontamination operation is carried out and comprises an assembly which is introduced into the vertical cylindrical vessel of the typical boiling water reactor through the open top. The assembly includes a circular track which is centered by guideways permanently installed in the reactor vessel and the track guides opposed pairs of nozzles through which water under very high pressure is directed at the wall for progressively cutting and sweeping a tenacious radioactive coating as the nozzles are driven around the track in close proximity to the vessel wall. The whole assembly is hoisted to a level above the top of the vessel by a crane, outboard slides on the assembly brought into engagement with the permanent guideways and the assembly progressively lowered in the vessel as the decontamination operation progresses. The assembly also includes a low pressure nozzle which forms a spray umbrella above the high pressure nozzles to contain radioactive particles dislodged during the decontamination
Decontamination of CANDU primary coolant system
International Nuclear Information System (INIS)
Pettit, P.J.
1975-01-01
Decontamination of radioactive systems is necessary to reduce personnel radiation exposures and also to reduce exposure during special work. Mechanical decontamination methods are sometimes useful, but most contaminated surfaces are inaccessible, so chemical decontamination often is preferred. The A-P Citrox method will remove most contaminants from CANDU systems, but is costly and long, damages components, and produces large quantities of radioactive liquid waste. The Redox cycling process is fast and inexpensive, produces only solid wastes, but removes small quantities of deposit from Monel only. The CAN-DECON process removes deposits from most materials including fuel cladding and has many other advantages. (author)
Personnel protective equipment total-encapsulating suit decontamination study using shower systems
International Nuclear Information System (INIS)
Menkhaus, D.E.
1991-01-01
This report documents an experimental evaluation, conducted at the Idaho National Engineering Laboratory, of a shower-based decontamination station for personnel wearing a Level A, total- encapsulating, chemical-protective suit. The decontamination station is used by personnel when egressing a dry, dusty environment contaminated with transuranic radionuclides. This system has the potential to minimize the risk of spreading the contaminants to clean areas. Two types of shower systems were evaluated, a drench shower and a multi-nozzle shower. A total-encapsulating suit, worn by personnel. was contaminated with soil containing 239 Pu. Pre- shower and post-shower contamination samples were collected and visual observations were made to evaluate the ability of the shower system to remove the contaminated dust and to obtain baseline data useful in designing a shower-based personnel decontamination system. 12 figs., 7 tabs
International Nuclear Information System (INIS)
Stiepani, Christoph
2011-01-01
Decontamination prior to Decommissioning and Dismantlement is imperative. Not only does it provide for minimization of personnel dose exposure but also maximization of the material volume available for free release. Since easier dismantling techniques in lower dose areas can be applied, the licensing process is facilitated and the scheduling and budgeting effort is more reliable. The most internationally accepted approach for Decontamination prior to Decommissioning projects is the Full System Decontamination (FSD). FSD is defined as the chemical decontamination of the primary cooling circuit, in conjunction with the main auxiliary systems. AREVA NP has long-term experience with Full System Decontamination for return to service of operating nuclear power plants as well as for decommissioning after shutdown. Since 1976, AREVA NP has performed over 500 decontamination applications and, from 1986, Decontaminations prior to Decommissioning projects which comprise virtually all NPP designs and plant conditions were performed: NPP designs: HPWR, PWR, and BWR by AREVA, Westinghouse, ABB and GE. Decontaminations performed shortly after final shutdown or several years later, and even after re-opening Safe Enclosure. High Alpha inventory and or low gamma/alpha ratio. Main Coolant chemistry (e.g., with and without Zn injection during operation). Fifteen Decontaminations prior to Decommissioning Projects have been performed successfully to date and the sixteenth FSD is now in the detailed engineering phase and is scheduled to commence late 2010. AREVA NP has developed a fully comprehensive approach for decontamination based on the CORD® (Chemical Oxidation Reduction Decontamination) Family, applied using the in-house designed decontamination equipment AMDA TM (Automatic Modular Decontamination Appliance). Based on the vast experience of AREVA NP in the field of decontamination, the Decontamination Concept for Decommissioning was developed. This concept ensures that the
New quaternary ammonium salts based decontaminants
Directory of Open Access Journals (Sweden)
Diana M. Popescu
2014-06-01
Full Text Available Decontamination after terrorist attacks or industrial accidents with biological and/or chemical agents („bio-chem“ must be fast and efficient, in order to reduce the number of victims and to eliminate the consequent damages. The decontamination of living biological agents (bacteria, viruses or nonliving ones (toxins, regulators and toxic chemicals could be accomplished by reactions of hydrolysis in various experimental conditions, in particular in alkaline medium, reactions with amines or ammonia, alcohols, phenols etc. and by their transformation into less toxic degradation products. “Bio-chem” intentional or unintentional contamination is a real risk, towards which an effective management must be available to prevent and control it. Decontamination is an essential measure to protect the personnel and the environment. Synthesis and testing of new „bio-chem“ decontaminants, based on quaternary ammonium salts, complete the arsenal of protection against chemical and biological agents. The most effective selected substances could be produced and used for decontamination in accordance with legal procedures
International Nuclear Information System (INIS)
Endo, Mitsuru; Endo, Mai; Kakizaki, Takao
2015-01-01
The Great East Japan Earthquake that occurred on March 11, 2011 resulted in the explosion of the TEPCO Fukushima 1st Nuclear Power Plant and the global dispersion of a large quantity of radioactive substances. A high radiation dose was particularly recorded in Fukushima prefecture several weeks after the accident, although the level is presently sufficiently low. However, considering that the adverse effects of low but extended exposure to radiation are yet to be negated, there is the urgent need for further decontamination. In our study, we focused on the efficient decontamination of radioactive substances in residential areas, for which we propose a high-pressure water jet system for washing road surfaces. The system differs from conventional systems of its type that were initially designed for use in the immediate environment of the nuclear reactors of the TEPCO Fukushima 1st Nuclear Power Plant. The proposed system consists of multiple washing, transporter, and server robots. The washing robots decontaminate the road surface using high-pressure water jets and are transported between washed and unwashed areas by the transporter robots. The server robots supply the water used for washing and absorb the polluted water together with ground dust. In this paper, we describe the concept of the system and present the results of decontamination experiments. Particular attention is given to the washing robot and its mechanism and control method. The results of the integration of the washing robot in an experimental system confirmed the feasibility of the proposed system. (author)
Operation of the radiation dose registration system for decontamination and related works
International Nuclear Information System (INIS)
Ogawa, Tsubasa; Yasutake, Tsuneo; Itoh, Atsuo; Miyabe, Kenjiro
2017-01-01
The radiation dose registration system for decontamination and related works was established on 15 November 2013. Radiation dose registration center and primary contractors of decontamination and related works manage decontamination registration and management system. As of 31 March 2017, 384 primary contractors joined in the radiation dose registration system for decontamination and related works. 383,087 quarterly exposure dose records for decontamination and related works were registered. Based on the registered data provided by the primary contractors, radiation dose registration center has released the statistical data that represent the radiation control status for workers engaged in radiation work at the work areas of decontamination and related works, etc. The statistical data shows that there were 40,377 workers engaged in decontamination and related works in 2015. The average exposure dose for workers was 0.6 mSv in 2015. The maximum exposure dose for workers was 7.8 mSv in 2015. Dose distribution by age of workers shows the range of 60 to 64 years old were most engaged in decontamination and related works in 2015. Dose distribution by gender of workers shows 97% of workers were male in 2015. From 2012 to 2015, about 95% of workers were exposed to radiation less than 3 mSv. And about 80% of workers were exposed to radiation less than 1 mSv. The average exposure dose per year was ranged from 0.5 to 0.7 mSv. (author)
A review of chemical decontamination systems for nuclear facilities
International Nuclear Information System (INIS)
Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.
1996-01-01
With the downsizing of the Department of Energy (DOE) complex, many of its buildings and facilities will be decommissioned and dismantled. As part of this decommissioning, some form of decontamination will be required. To develop an appropriate technology for in situ chemical decontamination of equipment interiors in the decommissioning of DOE nuclear facilities, knowledge of the existing chemical decontamination methods is needed. This paper attempts to give an up-to-date review of chemical decontamination methods. This survey revealed that aqueous systems are the most widely used for the decontamination and cleaning of metal surfaces. We have subdivided the aqueous systems by types of chemical solvent: acid, alkaline permanganate, highly oxidizing, peroxide, and proprietary. Two other systems, electropolishing and foams and gels, are also described in this paper
National Research Council Canada - National Science Library
Colclough, Stephen
1998-01-01
The XM21 Decontaminant Pumper module of the Modular Decontamination System was analyzed using finite element analysis techniques to show why the first design iteration passed transportation vibration...
2009-02-01
Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive expertise and specialized research facilities for the decontamination of surfaces...Agency (EPA) established an Interagency Agreement with the U.S. Army Edgewood Chemical Biological Center (ECBC) to take advantage of ECBC’s extensive...Detector (Waters Corporation, Milford, MA). Conductivity suppression was carried out using an ERIS 1000HP Autosuppressor ( Alltech Corporation, Deerfield
Full system decontamination (FSD) at NPP Stade prior to dismantling activities
International Nuclear Information System (INIS)
Christoph Stiepani; Karl Seidelmann
2006-01-01
Full text of publication follows: Introduction: Minimization of personnel dose rates and generation of material free for release is of the highest priority and requires Full System Decontamination (FSD) as a first and important measure when decommissioning Nuclear Power Plants. Framatome ANP has many years experience with Full System Decontaminations for operating nuclear power plants in general and for decommissioning in particular. The latest decommissioning project was the FSD at the PWR Stade which was permanently shut down in November 2003 after 31 years of operation. FSD was scheduled within a short period after shutdown and prior to decommissioning activities. Full System Decontamination at Stade: The PWR Stade is a 4 loop design. FSD included the entire primary circuit with RPV and the auxiliary systems (RHR, VCS and RWCU). The decontamination circuit had a total volume of ∼310 m 3 and an overall surface of ∼17000 m 2 . The Framatome ANP decontamination process HP/CORD R UV was selected for application. The decontamination was performed by using NPP systems in combination with the Framatome mobile decontamination equipment AMDA R (Automated Mobile Decontamination Appliance). A total of 4 decontamination cycles were performed and excellent results were obtained. The average decontamination factor (DF) was 160 for the steam generators with an outstanding ambient dose reduction factor (DRF) of 75. Conclusions: FSD at the PWR Stade has shown that the HP/CORD UV process yields excellent results in primary and auxiliary systems. The significant ambient dose reduction factor of 75 is remarkable. This very high DRF, no other decontamination application came even close, will result in excellent cost-benefit ratios for additional decommissioning activities at Stade. The applied HP/CORD UV process is not a specific decontamination process for decommissioning. Therefore the obtained decontamination and dose reduction factors demonstrate the advantage/potential for
Pearl, Thomas; Mantooth, Brent; Varady, Mark; Willis, Matthew
2014-03-01
Chemical warfare agent simulants are often used for environmental testing in place of highly toxic agents. This work sets the foundation for modeling decontamination of absorbing polymeric materials with the focus on determining relationships between agents and simulants. The correlations of agents to simulants must consider the three way interactions in the chemical-material-decontaminant system where transport and reaction occur in polymer materials. To this end, diffusion modeling of the subsurface transport of simulants and live chemical warfare agents was conducted for various polymer systems (e.g., paint coatings) with and without reaction pathways with applied decontamination. The models utilized 1D and 2D finite difference diffusion and reaction models to simulate absorption and reaction in the polymers, and subsequent flux of the chemicals out of the polymers. Experimental data including vapor flux measurements and dynamic contact angle measurements were used to determine model input parameters. Through modeling, an understanding of the relationship of simulant to live chemical warfare agent was established, focusing on vapor emission of agents and simulants from materials.
Decontamination using the high-pressure wet jet system
International Nuclear Information System (INIS)
Brandt, D.
1985-01-01
For decontaminating machine components, tools, instruments and scrap in nuclear plants the most varying decontamination procedures are used. At the nuclear power plant Wuergassen a mobile high-pressure wet jet unit, developed by Ernst Schmutz GmbH, was successfully used for the first time in extensive decontamination work. The recycling system integrated in the decontamination unit substantially reduces secondary waste, which is usually produced in large quantities by the dry jet method, and continually extracts the contaminated dirt thus guaranteeing full utilisation of the jet agent while preventing secondary contamination of the components to be treated. (orig.) [de
2006-06-01
best examples of this is glucose isomerase, which has been used in the commercial production of high fructose corn syrup (HFCS) since 1967.230 Most...EDGEWOOD CHEMICAL BIOLOGICAL CENTER U.S. ARMY RESEARCH, DEVELOPMENT AND ENGINEERING COMMAND ECBC-TR-489 CATALYTIC ENZYME-BASED METHODS FOR WATER ...TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION 1. LITERATURE SURVEY Joseph J. DeFrank RESEARCH AND TECHNOLOGY DIRECTORATE June 2006 Approved for
Decision Analysis System for Selection of Appropriate Decontamination Technologies
International Nuclear Information System (INIS)
Ebadian, M.A.; Boudreaux, J.F.; Chinta, S.; Zanakis, S.H.
1998-01-01
The principal objective for designing Decision Analysis System for Decontamination (DASD) is to support DOE-EM's endeavor to employ the most efficient and effective technologies for treating radiologically contaminated surfaces while minimizing personnel and environmental risks. DASD will provide a tool for environmental decision makers to improve the quality, consistency, and efficacy of their technology selection decisions. The system will facilitate methodical comparisons between innovative and baseline decontamination technologies and aid in identifying the most suitable technologies for performing surface decontamination at DOE environmental restoration sites
CATALYTIC ENZYME-BASED METHODS FOR WATER TREATMENT AND WATER DISTRIBUTION SYSTEM DECONTAMINATION
Current chemistry-based decontaminants for chemical or biological warfare agents and related toxic materials are caustic and have the potential for causing material and environmental damage. In addition, most are bulk liquids that require significant logistics and storage capabil...
Decontamination System Development of Radioative Activated Carbon using Micro-bubbles
Energy Technology Data Exchange (ETDEWEB)
Jeon, Jong seon; Kim, Wi soo [NESS, Daejeon (Korea, Republic of); Han, Byoung sub. [Enesys Co., Daejeon (Korea, Republic of)
2016-10-15
This study was aimed to develop a decontamination system by applying such technical characteristics that minimizes a generation of secondary wastes while decontaminating radiation wastes. The radioactive activated carbon is removed from the end-of-life air cleaning filter in replacement or decommission of nuclear power plant or nuclear facility. By removing radioactive activated carbon, the filter would be classified as a low radioactive contaminant. And thus the amount of radioactive wastes and the treatment cost would be decreased. We are in development of the activated carbon cleaning technique by utilizing micro-bubbles, which improve efficiency and minimize damage of activated carbon. The purpose of using micro-bubbles is to decontamination carbon micropore, which is difficult to access, by principle of cavitation phenomenon generated in collapse of micro-bubbles. In this study, we introduced the micro-bubble decontamination system developed to decontaminate activated carbon. For further researches, we will determine carbon weight change and the decontamination rate under the experimental conditions such as temperature and pH.
Decontamination System Development of Radioative Activated Carbon using Micro-bubbles
International Nuclear Information System (INIS)
Jeon, Jong seon; Kim, Wi soo; Han, Byoung sub.
2016-01-01
This study was aimed to develop a decontamination system by applying such technical characteristics that minimizes a generation of secondary wastes while decontaminating radiation wastes. The radioactive activated carbon is removed from the end-of-life air cleaning filter in replacement or decommission of nuclear power plant or nuclear facility. By removing radioactive activated carbon, the filter would be classified as a low radioactive contaminant. And thus the amount of radioactive wastes and the treatment cost would be decreased. We are in development of the activated carbon cleaning technique by utilizing micro-bubbles, which improve efficiency and minimize damage of activated carbon. The purpose of using micro-bubbles is to decontamination carbon micropore, which is difficult to access, by principle of cavitation phenomenon generated in collapse of micro-bubbles. In this study, we introduced the micro-bubble decontamination system developed to decontaminate activated carbon. For further researches, we will determine carbon weight change and the decontamination rate under the experimental conditions such as temperature and pH
Potassium permanganate for mercury vapor environmental control
Kuivinen, D. E.
1972-01-01
Potassium permanganate (KMnO4) was evaluated for application in removing mercury vapor from exhaust air systems. The KMnO4 may be used in water solution with a liquid spray scrubber system or as a solid adsorber bed material when impregnated onto a zeolite. Air samples contaminated with as much as 112 mg/cu m of mercury were scrubbed to 0.06mg/cum with the KMnO4-impregnated zeolite (molecular sieve material). The water spray solution of permanganate was also found to be as effective as the impregnated zeolite. The KMnO4-impregnated zeolite was applied as a solid adsorber material to (1) a hardware decontamination system, (2) a model incinerator, and (3) a high vacuum chamber for ion engine testing with mercury as the propellant. A liquid scrubber system was also applied in an incinerator system. Based on the results of these experiments, it is concluded that the use of KMnO4 can be an effective method for controlling noxious mercury vapor.
Chemical decontamination: an overview
International Nuclear Information System (INIS)
Shaw, R.A.; Wood, C.J.
1985-01-01
The source of radioactive contamination in various types of power reactors is discussed. The methods of chemical decontamination vary with the manner in which the radioactive contaminants are deposited on the surface. Two types of dilute decontamination systems are available. One system uses organic acids and chelating agents, which are mildly reducing in nature. In this process, the oxide contaminants are removed by simple acidic dissolution and reductive dissolution. The second type of decontamination process is based on low oxidation state metal ions, which are more strongly reducing and do not require a corrosion inhibitor. All processes commercially available for decontamination of power reactors are not detailed here, but a few key issues to be considered in the selection of a process are highlighted. 2 figures, 2 tables
Impact of LWR decontamination on radwaste systems
International Nuclear Information System (INIS)
Perrigo, L.D.; Divine, J.R.
1979-01-01
Increased radiation levels around certain reactors in the United States and accompanying increases in personnel exposures are causing a reexamination of options available to utilities to continue operation. One of the options is decontamination of the primary system to reduce radiation levels. The Battelle-Northwest study of decontamination and its impact on radwaste systems has been directed towards existing reactors and allied systems as they are employed during their operational lifetimes. Decommissioning and cleanup during such work are not within the scope of this project although certain processes and waste systems might be similar. Rupture debris cleanup represents a special situation that requires different design features and concepts and it is not a part of this study
Radiological experience on decontamination of moderator and associated system at NAPS-1
International Nuclear Information System (INIS)
Yadav, C.L.R.; Mitra, S.R.; Pawar, S.K.; Lal Chand
2000-01-01
Narora Atomic Power Station, the first of Indian standardized Pressurized Heavy Water Reactor, is faced with a problem of 60 Co contamination in moderator and its associated system. This contamination has resulted in increase of collective dose contribution. As a part of ALARA campaign in NAPS it was decided to decontaminate the moderator and associated systems and also incorporate modification which will further control the 60 Co contamination. As a part of decontamination program several experiments to determine the effectiveness of the chemical formulation on SS and cupro-nickel surfaces were carried out on various moderator system equipment before finalizing the formulation for full scale decontamination of moderator system. This paper gives an overview of various modifications in system and decontamination efficiency of various chemical formulation which were used for decontamination of moderator system (excluding calandria) and associated equipment. (author)
System decontamination as a tool to control radiation fields
Energy Technology Data Exchange (ETDEWEB)
Riess, R.; Bertholdt, H.O. [Siemens Power Generation Group, Erlangen (Germany)
1995-03-01
Since chemical decontamination of the Reactor Coolant Systems (RCS) and subsystems has the highest potential to reduce radiation fields in a short term this technology has gained an increasing importance. The available decontamination process at Siemens, i.e., the CORD processes, will be described. It is characterized by using permanganic acid for preoxidation and diluted organic acid for the decontamination step. It is a regenerative process resulting in very low waste volumes. This technology has been used frequently in Europe and Japan in both RCS and subsystems. An overview will be given i.e. on the 1993 applications. This overview will include plant, scope, date of performance, system volume specal features of the process removed activities, decon factor time, waste volumes, and personnel dose during decontamination. This overview will be followed by an outlook on future developments in this area.
Decontamination of the RA reactor heavy water system, Annex 9
International Nuclear Information System (INIS)
Maksimovic, Z.B.; Nikolic, R.M.; Marinkovic, M.D.; Jelic, Lj.M.
1963-01-01
Both stainless steel and aluminium parts of the RA reactor heavy water system system were decontaminated as well as the heavy water itself. System was contaminated with 60 Co. Decontamination factor was determined by activity measurements during distillation. Concentration of the corrosion products in the heavy water was measured by spectrochemical analysis, and found to be 0.1 - 1 mg/l. Chemical analyses of the aluminium and stainless steel surfaces showed that cobalt was adsorbed on the aluminium oxide layer. Water solution of 7%H 3 PO 4 + 2% CrO 3 was used for decontamination of the heavy water system and distillation device. This was found to be the most efficient solvent which does not affect stainless steel corrosion. Decontamination factors achieved were from 60 - 100. Decontamination results enabled determining the distribution of cobalt in the system: 10 Ci on the stainless steel parts, 50 Ci in the heavy water; and above 600 Ci on the fuel and experimental channels. Specific activity of 60 Co was calculated to be 15 Ci/g on the reactor channels, 8 Ci/g on the stainless steel parts and 3 Ci/g in the heavy water. Decontamination of the aluminium parts was not done because it was considered it could initiate corrosion. Since the efficiency of distillation is increased it was expected that permanent distillation would remove most of the activity in the reactor channels
Covering sources of toxic vapors with foam
International Nuclear Information System (INIS)
Aue, W. P.; Guidetti, F.
2009-01-01
In a case of chemical terrorism, first responders might well be confronted with a liquid source of toxic vapor which keeps spreading out its hazardous contents. With foam as an efficient and simple means, such a source could be covered up in seconds and the spread of vapors mitigated drastically. Once covered, the source could then wait for a longer time to be removed carefully and professionally by a decontamination team. In order to find foams useful for covering up toxic vapor sources, a large set of measurements has been performed in order to answer the following questions: - Which foams could be used for this purpose? - How thick should the foam cover be? - For how long would such a foam cover be effective? - Could the practical application of foam cause a spread of the toxic chemical? The toxic vapors sources included GB, GD and HD. Among the foams were 10 fire fighter foams (e.g. AFFF, protein) and the aqueous decontamination foam CASCAD. Small scale experiments showed that CASCAD is best suited for covering a toxic source; a 10 cm layer of it covers and decontaminates GB. The large scale experiments confirmed that any fire fighter foam is a suitable cover for a longer or shorter period.(author)
Nova target chamber decontamination study
International Nuclear Information System (INIS)
1979-05-01
An engineering study was performed to determine the most effective method for decontamination of the Nova target chamber. Manual and remote decontamination methods currently being used were surveyed. In addition, a concept that may not require in-situ decontamination was investigated. Based on the presently available information concerning material and system compatibility and particle penetration, it is recommended that a system of removable aluminum shields be considered. It is also recommended that a series of tests be performed to more precisely determine the vacuum compatibility and penetrability of other materials discussed in this report
Thermal decontamination of transformers: A new technology
International Nuclear Information System (INIS)
Colak, P.Z.
1992-01-01
After evaluating a number of methods for decontaminating or disposing of transformers that contained polychlorinated biphenyls (PCB), it was concluded that no entirely satisfactory procedure or technology was yet available which was permanent, effective, safe, relatively simple, and based on proven technology or conventional practice. The most desirable compromise appears to be thermal decontamination. It is proposed to decontaminate transformers by controlled incineration in a specially designed, indirect-fired furnace which resembles the conventional bell-type, vertical elevator, metal heat treating type of furnace. The design differs in the incorporation of those essential features required to achieve oxidation of the organic components, to provide internal air circulation needed to ensure efficient heat and mass transfer, and other factors. The most appropriate decontamination facility would provide for implementation of the following procedures: draining of PCB-containing liquids from the transformer; limited disassembly of the transformer, which in most instances would imply only removal of the top cover to expose the insides; and controlled incineration with any vapors generated being conducted to a secondary combustion chamber. Experiments were conducted in a kiln to simulate the proposed transformer incinerator. Results show that exposure of the transformer segments to a temperature in the 950-1,000 degree C range for over 90 min is generally sufficient to reduce the PCB content to under 1 ppM. Based on the work conducted, a suitable bell furnace was constructed and added to the Swan Hills (Alberta) waste treatment facility. 2 figs., 3 tabs
Dilute chemical decontamination program review
International Nuclear Information System (INIS)
Anstine, L.D.; Blomgren, J.C.; Pettit, P.J.
1980-01-01
The objective of the Dilute Chemical Decontamination Program is to develop and evaluate a process which utilizes reagents in dilute concentrations for the decontamination of BWR primary systems and for the maintenance of dose rates on the out-of-core surfaces at acceptable levels. A discussion is presented of the process concept, solvent development, advantages and disadvantages of reagent systems, and VNC loop tests. Based on the work completed to date it is concluded that (1) rapid decontamination of BWRs using dilute reagents is feasible; (2) reasonable reagent conditions for rapid chemical decontamination are: 0.01M oxalic acid + 0.005M citric acid, pH3.0, 90/degree/C, 0.5 to 1.0 ppm dissolved oxygen; (3) control of dissolved oxygen concentration is important, since high levels suppress the rate of decontamination and low levels allow precipitation of ferrous oxalate. 4 refs
Volume reduction and material recirculation by freon decontamination
International Nuclear Information System (INIS)
Berners, O.; Buhmann, D.; Yamashita, Y.; Yoshiaki, M.
1989-01-01
This paper discusses the use of freon in a large variety of decontamination in the nuclear and non-nuclear fields. As far as the contamination is loose or smerable, surfaces of nearly all materials can be decontaminated. Freon is electrically non-conductive, chemically neutral and has a low surface tension. So it is capable of creeping under the contaminant and loosening or dissolving it. Used freon can be collected, cleaned and recirculated. Its cleaning can be done easily by evaporation at its lower vapor point of about 48 degrees C (104 degrees F). Good decontamination results could be achieved, expensive materials, tools and equipment could be recirculated. Big volumes of materials could get separated from their contaminants, which is the real radioactive waste. Freon decontamination is an effective, overall economical and approved technology to volume reduction and material recirculation
National Research Council Canada - National Science Library
Gale, William F; Gale, Hyacinth S; Watson, Jean
2008-01-01
... vaporized hydrogen peroxide (VHP )* is discussed. The report is submitted in the context of a decontamination technology selection exercise, laboratory work conducted on the efficacy of thermal decontamination, and as a follow-on to a...
Full system chemical decontamination used in nuclear decommissioning
International Nuclear Information System (INIS)
Elder, George; Rottner, Bernard; Braehler, Georg
2012-01-01
The decommissioning of nuclear power stations at the end of the operational period of electricity generation offers technical challenges in the safe dismantling of the facility and the minimization of radioactive waste arising from the decommissioning activities. These challenges have been successfully overcome as demonstrated by decommissioning of the first generation of nuclear power plants. One of the techniques used in decommissioning is that of chemical decontamination which has a number of functions and advantages as given here: 1. Removal of contamination from metal surfaces in the reactors cooling systems. 2. Reduction of radioactive exposure to decommissioning workers 3. Minimization of metal waste by decontamination and recycling of metal components 4. Control of contamination when dismantling reactor and waste systems 5. Reduction in costs due to lower radiation fields, lower contamination levels and minimal metal waste volume for disposal. One such chemical decontamination technology was developed for the Electric Power Research Institute (EPRI) by Bradtec (Bradtec is an ONET Technologies subsidiary) and is known as the EPRI DFD system. This paper gives a description of the EPRI DFD system, and highlights the experience using the system. (orig.)
Surface decontamination studies using polyvinyl acetate based strippable polymer
International Nuclear Information System (INIS)
Rao, S.V.S.; Lal, K.B.
2004-01-01
Polyvinyl acetate based strippable polymer has been developed for surface decontamination. Stainless steel, mild steel, polyvinyl chloride and rubber have been selected as candidate materials for the radioactive decontamination studies. The ease of strippability and homogeneity of the polymer coating has been studied using infrared spectrophotometer. Decontamination of used radioactive respirator has been carried out and the peels obtained have been subjected to leaching and incineration studies. The infrared spectrophotometric studies also have been conducted to study the interaction between polyvinyl acetate and ions, like cesium, strontium and cobalt. (author)
International Nuclear Information System (INIS)
Nagamine, Haruo; Wakayama, Masanori; Nakamura, Hiroshi
2014-01-01
As a decontamination method for paved road surface, the 'Dry Ice Blast Decontamination System' has been developed. This decontamination system has characteristic as follows; 1) Generation of decontamination waste is extremely small, 2) not using water, 3) not damaging the pavement surface. In actual decontamination work, more than 60% average (maximum 84%) reduction rate of the radiation counting rate has been achieved. In addition to these features, this system prevent the diffusion into the surrounding and the radiation exposure of workers by sucking waste quickly using attached dust collecting function. This system is also characterized in that it does not cause a difference in skill by the operator because of faceted decontamination using repetitive motion by concatenating three pellet injection nozzle and self-propelled decontamination machine. (author)
International Nuclear Information System (INIS)
Lee, J.H.; Lim, Y.K.; Yang, H.Y.; Shin, S.W.; Song, M.J.
2003-01-01
Conventional and modified electrolytic decontamination experiments were performed in a solution of sodium sulfate for the decontamination of carbon steel as the simulated metal wastes which are generated in large amounts from nuclear power plants. The effect of reaction time, current density and concentration of electrolytes in the modified electrolytic decontamination system were examined to remove the surface contamination of the simulated radioactive metal wastes. As for the results of this research, the modified electrochemical decontamination process can decontaminate more effectively than the conventional decontamination process by applying different anode material which causes higher induced electro-motive forces. When 0.5 M sodium sulfate, 0.4 A/cm 2 current density and 30 minutes reaction time were applied in the modified process, a 16 μm thickness change that is expected to remove most surface contamination in radioactive metal wastes was achieved on carbon steel which is the main material of radioactive metal waste in nuclear power plants. The decontamination efficiency of metal waste showed similar results with the small and large lab-scale modified electrochemical system. The application of this modified electrolytic decontamination system is expected to play a considerable role for decontamination of radioactive metal waste in nuclear power plants in the near future. (author)
Development of small size wall decontamination robot systems in nuclear power plants
International Nuclear Information System (INIS)
Fujita, Tsuneaki; Takahashi, Tsuyosi
2004-01-01
This paper describes the development of wall decontamination robot systems for nuclear power plants. In nuclear power plants, it is required to reduce maintenance costs, including annual inspection, repairs and so on. Most of such maintenance activities are actually performed after decontamination processes are completed. In particular, the decontamination process of reactor wells is very important for reducing the radiation exposure of human workers. In the past, decontamination of reactor wells used to be done by extra large machine and tools, which caused long working hours and tiresome works. It was one of the reasons maintenance costs couldn't have been easily reduced. There are narrow spaces in the reactor wells that have to be decontaminated by human workers. In order to minimize the radiation exposure to humans, wall decontamination robot systems have been developed. The decontamination robots have rolled brushes and suction mechanisms and are capable of removing contaminants attached to the wall surface of the reactor wells. By making the robots smaller, it is possible to work in narrower spaces. In this paper, the effectiveness of decontamination by the developed robots is shown through experiments in the actual nuclear power plants. (author)
Full system decontamination (FSD) for sustainable dose reduction
International Nuclear Information System (INIS)
Stiepani, Christoph; Sempere-Belda, Luis; Topf, Christian; Basu, Ashim
2012-09-01
Nuclear power plants experience an increase in dose rates during operation due to the build-up of the activity inventory. The activity build-up is influenced by the construction materials, past and present water chemistries, and the individual operating history of the plant. Depending on these factors the dose levels in an operating plant may reach a point in which concrete actions to reduce the overall radiation exposure become necessary. In the past dose reduction plans were performed, based on - Modification in coolant water chemistry - Substitution of Cobalt containing materials - Outage optimization program - Installation of permanent shielding - Decontamination The dose rate reduction took several years and today a stagnation of further dose rate reduction can be seen. Therefore AREVA has developed the Concept for Sustainable Dose Reduction in Operating BWRs and PWRs. This is a program of joint corrective measures to minimize dose levels rapidly and keep them low for continued operation. It can be applied in plants from all constructors and designs. The concept is based fully on the application of proven technologies, including: - Full System Decontamination with AREVA's decontamination process HP/CORD UV to minimize the activity inventory - The formation of new, very stable protective oxides on the system surfaces including injection of depleted zinc - Introduction of advanced water chemistry for maintaining the low dose levels achieved during ongoing operation The implementation of this program is particularly interesting for plants with a long operation history, especially when considering life extension. The latest application was performed successfully at the German PWR Grafenrheinfeld in 2010. In this paper the concept for sustainable dose reduction will be outlined and the site application detailed and the achieved results at PWR Grafenrheinfeld will be described. The recontamination after one cycle will be outlined in a second paper. (authors)
International Nuclear Information System (INIS)
Yoon, Suk Bon; Jung, Chong Hun; Kim, Chang Ki; Choi, Byung Seon; Lee, Kune Woo; Moon, Jei Kwon
2011-01-01
Decontamination of nuclear facilities is necessary to reduce the radiation field during normal operations and decommissioning of complex equipment such as stainless steel components, other iron-based steel and alloys, metal surfaces, structural materials and so on. Chemical decontamination technology in particular is a highly effective method to remove the radioactive contamination through a chemical dissolution or a redox reaction. However, this method has the serious drawback due to the generation of large amounts of the radioactive liquid wastes. Recently, a few literatures have been reported for the preparation of the chemical gel decontaminants to reduce the amount of the radioactive liquid wastes and to enhance the decontamination efficiency through increasing the contact time between the gels and the radioactive contaminants. In the preparation of the chemical gels, the control of the viscosity highly depends on the amount of a coviscosifier used among the components of the chemical gels consisted of a viscosifier, a coviscosifier, and a chemical decontaminant. In this works, a new effective method for the preparation of the chemical gel was investigated by introducing the organic solvents. The mixture solution of the coviscosifier and organic solvent was more effective in the control of the viscosity compared with that of the coviscosifier only in gels. Furthermore, the decontamination efficiency of the chemical gels measured by using the multi-channel analyzer (MCA) showed the high decontamination factor for Co-60 and Cs-137 contaminated on the surface of the stainless steel 304
International Nuclear Information System (INIS)
Draine, Amanda E.; Walter, Ken J.; Johnson, Thomas E.
2008-01-01
Full text: Medical radioisotopes used to treat and diagnose patients often contaminate surfaces in patient treatment rooms. They are typically short-lived and decay within a matter of days or weeks. However, down time in a medical facility related to radioisotope contamination is costly and can impact patient care. Most liquid or solid spills can be contained and disposed in radioactive wastes fairly completely and quickly; however residual contamination may remain on the contacted surface. Although liquid decontamination agents can be used to address the issue of residual contamination, they often require multiple applications with attendant scrubbing and wiping. Liquid decontamination can also produce large volumes of low-level radioactive waste. To look at reducing radioactive waste volumes, research was conducted on the efficacy of three low-volume peel able decontamination agents. Testing was performed on hard surfaces, such as vinyl composition floor tiles and stainless steel, which are found in many hospitals, research laboratories, and universities. The tiles were contaminated with the medical use isotopes of 99m Tc, Tl-201, and I-131 and subsequently decontaminated with one of the three decontamination agents. Quantitative and qualitative data were obtained for each of three different peel able decontamination agent formulations. Quantitative data included environmental temperature and relative humidity, application thickness, dry time, contact time, and decontamination efficacy of the agents on the tested surfaces. Qualitative factors included ease of application and pee lability, as well as sag resistance and odor of each agent. Initial studies showed that under standard conditions there were reproducible differences in the decontamination efficacies among the three different decontamination formulations. (author)
Active Waste Materials Corrosion and Decontamination Tests
International Nuclear Information System (INIS)
Danielson, M.J.; Elmore, M.R.; Pitman, S.G.
2000-01-01
Stainless steel alloys, 304L and 316L, were corrosion tested in representative radioactive samples of three actual Hanford tank waste solutions (Tanks AW-101, C-104, AN-107). Both the 304L and 316L exhibited good corrosion performance when immersed in boiling waste solutions. The maximum general corrosion rate was 0.015 mm/y (0.60 mils per year). Generally, the 304L had a slightly higher rate than the 316L. No localized attack was observed after 122 days of testing in the liquid phase, liquid/vapor phase, or vapor phase. Radioactive plate-out decontamination tests indicated that a 24-hour exposure to 1 und M HNO 3 could remove about 99% of the radioactive components in the metal film when exposed to the C-104 and AN-107 solutions. The decontamination results are less certain for the AW-101 solution, since the initial contamination readings exceeded the capacity of the meter used for this test
Systems analysis of decontamination options for civilian vehicles.
Energy Technology Data Exchange (ETDEWEB)
Foltz, Greg W.; Hoette, Trisha Marie
2010-11-01
The objective of this project, which was supported by the Department of Homeland Security (DHS) Science and Technology Directorate (S&T) Chemical and Biological Division (CBD), was to investigate options for the decontamination of the exteriors and interiors of vehicles in the civilian setting in order to restore those vehicles to normal use following the release of a highly toxic chemical. The decontamination of vehicles is especially challenging because they often contain sensitive electronic equipment, multiple materials some of which strongly adsorb chemical agents, and in the case of aircraft, have very rigid material compatibility requirements (i.e., they cannot be exposed to reagents that may cause even minor corrosion). A systems analysis approach was taken examine existing and future civilian vehicle decontamination capabilities.
Decontamination of radioactive isotopes
International Nuclear Information System (INIS)
Despotovic, R.; Music, S.; Subotic, B.; Wolf, R.H.H.
1979-01-01
Removal of radioactive isotopes under controlled conditions is determined by a number of physical and chemical properties considered radiocontaminating and by the characteristics of the contaminated object. Determination of quantitative and qualitative factors for equilibrium in a contamination-decontamination system provides the basis for rational and successful decontamination. The decontamination of various ''solid/liquid'' systems is interesting from the scientific and technological point of view. These systems are of great importance in radiation protection (decontamination of various surfaces, liquids, drinking water, fixation or collection of radiocontaminants). Different types of decontamination systems are discussed. The dependence of rate and efficiency of the preparation conditions and on the ageing of the scavenger is described. The influence of coagulating electrolyte on radioactive isotope fixation efficiency was also determined. The fixation of fission radionuclide on oxide scavengers has been studied. The connection between fundamental investigations and practical decontamination of the ''solid/liquid'' systems is discussed. (author)
Jung, Hyunsook; Choi, Seungki
2017-10-15
The evaporation, degradation, and decontamination of sulfur mustard on environmental matrices including sand, concrete, and asphalt are described. A specially designed wind tunnel and thermal desorber in combination with gas chromatograph (GC) produced profiles of vapor concentration obtained from samples of the chemical agent deposited as a drop on the surfaces of the matrices. The matrices were exposed to the chemical agent at room temperature, and the degradation reactions were monitored and characterized. A vapor emission test was also performed after a decontamination process. The results showed that on sand, the drop of agent spread laterally while evaporating. On concrete, the drop of the agent was absorbed immediately into the matrix while spreading and evaporating. However, the asphalt surface conserved the agent and slowly released parts of the agent over an extended period of time. The degradation reactions of the agent followed pseudo first order behavior on the matrices. Trace amounts of the residual agent present at the surface were also released as vapor after decontamination, posing a threat to the exposed individual and environment.
Performance assessment of the In-Well Vapor-Stripping System
Energy Technology Data Exchange (ETDEWEB)
Gilmore, T.J.; White, M.D.; Spane, F.A. Jr. [and others
1996-10-01
In-well vapor stripping is a remediation technology designed to preferentially extract volatile organic compounds dissolved in groundwater by converting them to a vapor phase and then treating the vapor. This vapor-stripping system is distinctly different from the more traditional in situ air-sparging concept. In situ sparging takes place in the aquifer formation; in-well vapor stripping takes place within the well casing. The system was field demonstrated at Edwards Air Force Base, California; the first-time demonstration of this technology in the United States. Installation and testing of the system were completed in late 1995, and the demonstration was operated nearly continuously for 6 months (191 days) between January 16 and July 25, 1996. Postdemonstration hydrochemical sampling continued until September 1996. The demonstration was conducted by collaborating researchers from Pacific Northwest National Laboratory (a) and Stanford University as part of an interim cleanup action at the base. Edwards Air Force Base and its environmental subcontractor, Earth Technology Corporation, as well as EG&G Environmental, holders of the commercial rights to the technology, were also significant contributors to the demonstration.
Comparison of dilute chemical decontaminations of RAPS-2 full primary heat transport system
International Nuclear Information System (INIS)
Bhat, H.R.
2000-01-01
First ever attempt to decontaminate a full primary system of an Indian PHWR was carried out at Rajasthan Atomic Power Station Unit -2 (RAPS-2) in August 1992. The decontamination factors obtained were moderate. The second attempt to decontaminate the same system was made in February 1996 with a different formulation. The decontamination factors obtained were lesser than the earlier attempt. The details of the two campaigns and their relative merits and demerits are discussed. Some more studies are required to be done before further implementation of the picolonic acid/ascorbic acid formulation. The 1992 attempt was with picolinic acid and ascorbic acid whereas the 1996 attempt was with EDTA + citric acid + ascorbic Acid (EAC ) formulation. A number of lessons were learnt from the first campaign and the improvements were applied during the subsequent decontamination campaigns at Madras Atomic Power station. The total iron removed and various radio nuclides removed are also detailed in the paper. Picolonic acid and ascorbic acid is a better formulation for decontamination of full PHT systems of Indian PHWRs. Use of EAC formulation generates a lot of crud which settles in narrow clearances. Picolonic Acid/Ascorbic Acid formulation does not generate any crud. Decontamination using a single cycle of the picolonic acid/ascorbic acid formulation is more effective than the decontamination using three cycles of EAC formulation. (author)
Oxidative Tritium Decontamination System
International Nuclear Information System (INIS)
Gentile, Charles A.; Parker, John J.; Guttadora, Gregory L.; Ciebiera, Lloyd P.
2002-01-01
The Princeton Plasma Physics Laboratory, Tritium Systems Group has developed and fabricated an Oxidative Tritium Decontamination System (OTDS), which is designed to reduce tritium surface contamination on various components and items. The system is configured to introduce gaseous ozone into a reaction chamber containing tritiated items that require a reduction in tritium surface contamination. Tritium surface contamination (on components and items in the reaction chamber) is removed by chemically reacting elemental tritium to tritium oxide via oxidation, while purging the reaction chamber effluent to a gas holding tank or negative pressure HVAC system. Implementing specific concentrations of ozone along with catalytic parameters, the system is able to significantly reduce surface tritium contamination on an assortment of expendable and non-expendable items. This paper will present the results of various experimentation involving employment of this system
International Nuclear Information System (INIS)
Bougault, R.; Brou, R.; Colin, J.; Cussol, D.; Durand, D.; Le Brun, C.; Lecolley, J.F.; Lopez, O.; Louvel, M.; Nakagawa, T.; Peter, J.; Regimbart, R.; Steckmeyer, J.C.; Tamain, B.; Vient, E.; Yuasa-Nakagawa, K.; Wieloch, A.
1998-01-01
A particular case of the hot nuclei de-excitation is the total nuclear dislocation into light particles (n, p, d, t, 3 He and α). Such events were first observed at bombarding energies lower than 100 MeV/nucleon due to high detection performances of the INDRA multidetector. The light system Ar + Ni was studied at several bombarding energies ranging from 32 to 95 MeV/nucleon. The events associated to a total vaporization of the system occur above the energy threshold of ∼ 50 MeV/nucleon. A study of the form of these events shows that we have essentially two sources. The excitation energy of these sources may be determined by means of the kinematic properties of their de-excitation products. A preliminary study results in excitation energy values of the order 10 - 14 MeV/nucleon. The theoretical calculation based on a statistical model modified to take into account high excitation energies and excited levels in the lightest nuclei predicts that the vaporization of the two partner nuclei in the Ar + Ni system takes place when the excitation energy exceeds 12 MeV/nucleon what is qualitatively in agreement with the values deduced from calorimetric analysis
Large-bore pipe decontamination
International Nuclear Information System (INIS)
Ebadian, M.A.
1998-01-01
The decontamination and decommissioning (D and D) of 1200 buildings within the US Department of Energy-Office of Environmental Management (DOE-EM) Complex will require the disposition of miles of pipe. The disposition of large-bore pipe, in particular, presents difficulties in the area of decontamination and characterization. The pipe is potentially contaminated internally as well as externally. This situation requires a system capable of decontaminating and characterizing both the inside and outside of the pipe. Current decontamination and characterization systems are not designed for application to this geometry, making the direct disposal of piping systems necessary in many cases. The pipe often creates voids in the disposal cell, which requires the pipe to be cut in half or filled with a grout material. These methods are labor intensive and costly to perform on large volumes of pipe. Direct disposal does not take advantage of recycling, which could provide monetary dividends. To facilitate the decontamination and characterization of large-bore piping and thereby reduce the volume of piping required for disposal, a detailed analysis will be conducted to document the pipe remediation problem set; determine potential technologies to solve this remediation problem set; design and laboratory test potential decontamination and characterization technologies; fabricate a prototype system; provide a cost-benefit analysis of the proposed system; and transfer the technology to industry. This report summarizes the activities performed during fiscal year 1997 and describes the planned activities for fiscal year 1998. Accomplishments for FY97 include the development of the applicable and relevant and appropriate regulations, the screening of decontamination and characterization technologies, and the selection and initial design of the decontamination system
Electropolishing decontamination system for high-level waste canisters
International Nuclear Information System (INIS)
Larson, D.E.; Berger, D.N.; Allen, R.P.; Bryan, G.H.; Place, B.G.
1988-10-01
As part of a US Department of Energy (DOE) project agreement with the Federal Ministry for Research and Technology (BMFT) in the Federal Republic of Germany (FRG). The Nuclear Waste Treatment Program at the Pacific Northwest Laboratory (PNL) is preparing 30 radioactive canisters containing borosilicate glass for use in high-level waste repository related tests at the Asse Salt Mine. After filling, the canisters will be welded closed and decontaminated in preparation for shipping to the FRG. Electropolishing was selected as the primary decontamination approach, and an electropolishing system with associated canister inspection equipment has been designed and fabricated for installation in a large hot cell. This remote electropolishing system, which is currently undergoing preliminary testing, is described in this report. 3 refs., 3 figs., 1 tab
Toshiba's decontamination technologies for the decommissioning
International Nuclear Information System (INIS)
Inoue, Yuki; Yaita, Yumi; Sakai, Hitoshi
2011-01-01
For the decommissioning, two types of decontamination process are necessary, 1) system decontamination before dismantling and 2) decontamination of dismantling waste. Toshiba has been developing the decontamination technologies for the both purposes from the viewpoint of minimizing the secondary waste. For the system decontamination before dismantling, chemical decontamination process, such as T-OZON, can be applicable for stainless steel or carbon steel piping. For the decontamination of dismantling waste, several types of process have been developed to apply variety of shapes and materials. For the simple shape materials, physical decontamination process, such as blast decontamination, is effective. We have developed new blast decontamination process with highly durable zirconia particle. It can be used repeatedly and secondary waste can be reduced compared with conventional blast particle. For the complex shape materials, chemical decontamination process can be applied that formic acid decontamination process for carbon steel and electrolytic reduction decontamination process with organic acid for stainless steel. These chemicals can be decomposed to carbon dioxide and water and amount of secondary waste can be small. (author)
A decontamination technique for decommissioning waste
International Nuclear Information System (INIS)
Heki, H.; Hosaka, K.; Kuribayashi, N.; Ishikura, T.
1993-01-01
A large amount of radioactive metallic waste is generated from decommissioned commercial nuclear reactors. It is necessary from the point of environmental protection and resource utilization to decontaminate the contaminated metallic waste. A decommissioning waste processing system has been previously proposed considering such decommissioning waste characteristics as its large quantity, large radioactivity range, and various shapes and materials. The decontamination process in this system was carried out by abrasive blasting as pretreatment, electrochemical decontamination as the main process, and ultrasonic cleaning in water as post-treatment. For electrochemical decontamination, electrolytic decontamination for simple shaped waste and REDOX decontamination for complicated shaped waste were used as effective decontamination processing. This time, various kinds of actual radioactive contaminated samples were taken from operating power plants to simulate the decontamination of decommissioning waste. After analyzing the composition, morphogenesis and surface observation, electrolytic decontamination, REDOX decontamination, and ultrasonic cleaning experiments were carried out by using these samples. As a result, all the samples were decontaminated below the assumed exemption level(=4 x 10 -2 Bq/g). A maximum decontamination factor of over 104 was obtained by both electrolytic and REDOX decontamination. The stainless steel sample was easy to decontaminate in both electrochemical decontaminations because of its thin oxidized layer. The ultrasonic cleaning process after electrochemical decontamination worked effectively for removing adhesive sludge and the contaminated liquid. It has been concluded from the results mentioned above that electrolytic decontamination and REDOX decontamination are effective decontamination process for decontaminating decommissioning waste
International Nuclear Information System (INIS)
Rood, L.B.; Law, C.G. Jr.
1972-01-01
Evaporator decontamination factors were studied as functions of boiloff rate, volume reduction, and feed pH. A bench-scale vertical tube evaporator operating on simulated intermediate level nuclear wastes was used. Decontamination factors were not found to be strong functions of volume reduction or boiloff below vapor velocities of 25 lb/ft 2 -hr. At higher vapor fluxes, splashing was encountered. Foaming occurred at a feed pH of 6 but not at higher values. The presence of radioisotopes in the feed had no effect on evaporator performance
Gentilly 1: decontamination program
International Nuclear Information System (INIS)
Le, H.; Denault, P.
1985-01-01
The Gentilly 1 station, a 250-MW(e) light-water-cooled and heavy-water-moderated nuclear reactor, is being decommissioned to a static state (variant of stage 1) condition by Atomic Energy of Canada Limited (AECL). The scope of the decontamination program at the Gentilly 1 site includes the fuel pool and associated systems, the decontamination center, the laundry, the feedwater pumps and piping systems, the service building ventilation and drainage systems, and miscellaneous floor and wall areas. After an extensive literature review for acceptable decontamination methods, it was decided that the decontamination equipment used at Gentilly 1 during the program would include a hydrolaser, a scarifier, chipping hammers, a steam cleaner, an ultrasonic bath, and cutting tools. In addition, various foams, acids, detergents, surfactants, and abrasives are used alone and in tandem with the above equipment. This paper highlights the result of these decontaminations, their effectiveness, and the recommendation for future application. The methodology in performing these operations are also presented
Chemical decontamination of the residual heat removal system (RHRS) of Flamanville 1
International Nuclear Information System (INIS)
Steinkuhler, Claude; Coomans, Reginald; Koen, Lenie
2007-01-01
The purpose of the decontamination of the RHRS at Flamanville 1 was the reduction of the general dosimetry and the elimination of hot spots. This was done to allow the maintenance on the RHRS equipment. The main challenge of this project was the execution of a complicated operation on the critical path of a shutdown. The redox attack of the oxides at the surface of the circuit in Flamanville, was performed by an EDF qualified process of the EMMAC family. The functions required by the decontamination system were very diverse and therefore an existing decontamination loop, which was previously developed for the decontamination of small system volumes, was re-developed and adapted for bigger circuits. Due to different reasons, an important delay on the planning happened. Therefore, only one cycle EMMAg was performed, totalling 2 hours of decontamination. Despite this, a DRRF (dose rate reduction factor) of 3,7 average was reached. The re-designed equipment and a shortened process were validated during this project. An acceptable DRRF was reached with no delay on the critical path. The capability of maintenance on the RHRS equipment is recovered with a gain of factor 5 on dosimetry. (authors)
Summary of sodium removal and decontamination programs in the USA
International Nuclear Information System (INIS)
Steele, O.P.; Brehm, W.F.
1978-01-01
The goals of the United States Department of Energy sodium removal and decontamination programs are: 1) to identify plant requirements and develop safe effective processes for sodium removal, both for experimental facilities and for reactor components; 2) to develop effective decontamination processes for removing deposited radioactivity; 3) to establish and put into use a set of workable criteria for requalification and return to service of components after sodium removal and decontamination; 4) to design, build and operate facilities in which to perform the sodium removal and decontamination operations. This paper gives a summary of progress toward each of these goals; details will be presented in other papers at this meeting. Three basic processes for sodium removal have been investigated extensively: the use of water vapor in an inert carrier gas, the use of an alcohol-type reagent, and evaporation. The process development work on the first two processes has been essentially completed. The evaporative process is still under development, but preliminary parameters have been established
INTEGRATED VERTICAL AND OVERHEAD DECONTAMINATION SYSTEM
Energy Technology Data Exchange (ETDEWEB)
M.A. Ebadian, Ph.D.
1999-01-01
This report summarizes the activities performed during FY98 and describes the planned activities for FY99. Accomplishments for FY98 include identifying and selecting decontamination, the screening of potential characterization technologies, development of minimum performance factors for the decontamination technology, and development and identification of Applicable, Relevant and Appropriate Regulations (ARARs).
INTEGRATED VERTICAL AND OVERHEAD DECONTAMINATION SYSTEM
International Nuclear Information System (INIS)
Ebadian, M.A.
1999-01-01
This report summarizes the activities performed during FY98 and describes the planned activities for FY99. Accomplishments for FY98 include identifying and selecting decontamination, the screening of potential characterization technologies, development of minimum performance factors for the decontamination technology, and development and identification of Applicable, Relevant and Appropriate Regulations (ARARs)
Ontario Hydro decontamination experience
Energy Technology Data Exchange (ETDEWEB)
Lacy, C S; Patterson, R W; Upton, M S [Chemistry and Metallurgy Department, Central Production Services, Ontario Hydro, ON (Canada)
1991-04-01
Ontario Hydro currently operates 18 nuclear electric generating units of the CANDU design with a net capacity of 12,402 MW(e). An additional 1,762 MW(e) is under construction. The operation of these facilities has underlined the need to have decontamination capability both to reduce radiation fields, as well as to control and reduce contamination during component maintenance. This paper presents Ontario Hydro decontamination experience in two key areas - full heat transport decontamination to reduce system radiation fields, and component decontamination to reduce loose contamination particularly as practised in maintenance and decontamination centres. (author)
Ontario Hydro decontamination experience
International Nuclear Information System (INIS)
Lacy, C.S.; Patterson, R.W.; Upton, M.S.
1991-01-01
Ontario Hydro currently operates 18 nuclear electric generating units of the CANDU design with a net capacity of 12,402 MW(e). An additional 1,762 MW(e) is under construction. The operation of these facilities has underlined the need to have decontamination capability both to reduce radiation fields, as well as to control and reduce contamination during component maintenance. This paper presents Ontario Hydro decontamination experience in two key areas - full heat transport decontamination to reduce system radiation fields, and component decontamination to reduce loose contamination particularly as practised in maintenance and decontamination centres. (author)
Fuel decontamination at Ringhals 1 with the new decontamination process IcedecTM
International Nuclear Information System (INIS)
Fredriksson, E.; Ivars, R.; Rosengren, A.; Granath, G.
2003-01-01
The new fuel decontamination technique ICEDEC TM , which has been developed by Westinghouse, is based on abrasion of fuel crud with ice particles. A mixture of ice and water is led continuously through the fuel assembly, which is placed in a specially designed fuel decontamination container connected to a closed loop recirculation system. The ice particles scrape off the loose crud from the fuel surfaces and a mixture of crud and water from the melted ice is then led to a filter unit were the crud is separated from the water. In this paper results of fuel decontamination tests of two-year-old and spent fuel assemblies during spring 2001 at Ringhals 1 are presented. The fuel crud was only released when ice particles passed through the fuel assembly and stopped within ten seconds after the feeding of ice particles had ceased. The activity release from the fuel could thus be performed in a controlled way making the process easy to manage and survey. Activity measurements confirmed that about 50% of the loose crud was removed from the fuel surfaces of the two-year-old assembly. Fuel inspection after the decontamination process showed no influence on the fuel integrity. Furthermore, no enhanced personnel radiation dose was involved with the fuel decontamination compared to normal fuel services. (authors)
Dry decontamination for tritiated wastes
International Nuclear Information System (INIS)
Shi Zhengkun; Wu Tao; Dan Guiping; Xie Yun
2009-01-01
To aim at decontamination of tritiated wastes, we have developed and fabricated a dry tritium decontamination system, which is designed to reduce tritium surface contamination of various alloy by UV, ozone and heating. The result indicates that the elevation of temperature can obviously improve decontamination effect. With 3 h irradiation by 365 nm UV at 220 degree C, it has a decontamination rate of 99% to stainless steel surface. Ozone can more obviously improve decontamination effect when metal was heated. Ozone has a decontamination effect beyond 95% to stainless steel, aluminum and brass at 220 degree C. Tritium surface concentration of metal has a little increase after decontamination. (authors)
Next Generation Non-particulate Dry Nonwoven Pad for Chemical Warfare Agent Decontamination
Energy Technology Data Exchange (ETDEWEB)
Ramkumar, S S; Love, A; Sata, U R; Koester, C J; Smith, W J; Keating, G A; Hobbs, L; Cox, S B; Lagna, W M; Kendall, R J
2008-05-01
New, non-particulate decontamination materials promise to reduce both military and civilian casualties by enabling individuals to decontaminate themselves and their equipment within minutes of exposure to chemical warfare agents or other toxic materials. One of the most promising new materials has been developed using a needlepunching nonwoven process to construct a novel and non-particulate composite fabric of multiple layers, including an inner layer of activated carbon fabric, which is well-suited for the decontamination of both personnel and equipment. This paper describes the development of a composite nonwoven pad and compares efficacy test results for this pad with results from testing other decontamination systems. The efficacy of the dry nonwoven fabric pad was demonstrated specifically for decontamination of the chemical warfare blister agent bis(2-chloroethyl)sulfide (H or sulfur mustard). GC/MS results indicate that the composite fabric was capable of significantly reducing the vapor hazard from mustard liquid absorbed into the nonwoven dry fabric pad. The mustard adsorption efficiency of the nonwoven pad was significantly higher than particulate activated carbon (p=0.041) and was similar to the currently fielded US military M291 kit (p=0.952). The nonwoven pad has several advantages over other materials, especially its non-particulate, yet flexible, construction. This composite fabric was also shown to be chemically compatible with potential toxic and hazardous liquids, which span a range of hydrophilic and hydrophobic chemicals, including a concentrated acid, an organic solvent and a mild oxidant, bleach.
Decontamination Efficacy and Skin Toxicity of Two Decontaminants against Bacillus anthracis.
Directory of Open Access Journals (Sweden)
Chad W Stratilo
Full Text Available Decontamination of bacterial endospores such as Bacillus anthracis has traditionally required the use of harsh or caustic chemicals. The aim of this study was to evaluate the efficacy of a chlorine dioxide decontaminant in killing Bacillus anthracis spores in solution and on a human skin simulant (porcine cadaver skin, compared to that of commonly used sodium hypochlorite or soapy water decontamination procedures. In addition, the relative toxicities of these decontaminants were compared in human skin keratinocyte primary cultures. The chlorine dioxide decontaminant was similarly effective to sodium hypochlorite in reducing spore numbers of Bacillus anthracis Ames in liquid suspension after a 10 minute exposure. After five minutes, the chlorine dioxide product was significantly more efficacious. Decontamination of isolated swine skin contaminated with Bacillus anthracis Sterne with the chlorine dioxide product resulted in no viable spores sampled. The toxicity of the chlorine dioxide decontaminant was up to two orders of magnitude less than that of sodium hypochlorite in human skin keratinocyte cultures. In summary, the chlorine dioxide based decontaminant efficiently killed Bacillus anthracis spores in liquid suspension, as well as on isolated swine skin, and was less toxic than sodium hypochlorite in cultures of human skin keratinocytes.
Design of a tritium decontamination workstation based on plasma cleaning
International Nuclear Information System (INIS)
Antoniazzi, A.B.; Shmayda, W.T.; Fishbien, B.F.
1993-01-01
A design for a tritium decontamination workstation based on plasma cleaning is presented. The activity of tritiated surfaces are significantly reduced through plasma-surface interactions within the workstation. Such a workstation in a tritium environment can routinely be used to decontaminate tritiated tools and components. The main advantage of such a station is the lack of low level tritiated liquid waste. Gaseous tritiated species are the waste products with can with present technology be separated and contained
Enhanced toxic cloud knockdown spray system for decontamination applications
Betty, Rita G [Rio Rancho, NM; Tucker, Mark D [Albuquerque, NM; Brockmann, John E [Albuquerque, NM; Lucero, Daniel A [Albuquerque, NM; Levin, Bruce L [Tijeras, NM; Leonard, Jonathan [Albuquerque, NM
2011-09-06
Methods and systems for knockdown and neutralization of toxic clouds of aerosolized chemical or biological warfare (CBW) agents and toxic industrial chemicals using a non-toxic, non-corrosive aqueous decontamination formulation.
Gross decontamination experiment report
International Nuclear Information System (INIS)
Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment
Gross decontamination experiment report
Energy Technology Data Exchange (ETDEWEB)
Mason, R.; Kinney, K.; Dettorre, J.; Gilbert, V.
1983-07-01
A Gross Decontamination Experiment was conducted on various levels and surfaces of the TMI - Unit 2 reactor building in March 1982. The polar crane, D-rings, missile shields, refueling canals, refueling bridges, equipment, and elevations 305' and 347'-6'' were flushed with low pressure water. Additionally, floor surfaces on elevation 305' and floor surfaces and major pieces of equipment on elevation 347'-6'' were sprayed with high pressure water. Selective surfaces were decontaminated with a mechanical scrubber and chemicals. Strippable coating was tested and evaluated on equipment and floor surfaces. The effectiveness, efficiency, and safety of several decontamination techniques were established for the large, complex decontamination effort. Various decontamination equipment was evaluated and its effectiveness was documented. Decontamination training and procedures were documented and evaluated, as were the support system and organization for the experiment.
Laser-based characterization and decontamination of contaminated facilities
International Nuclear Information System (INIS)
Leong, K.H.; Hunter, B.V.; Grace, J.E.; Pellin, M.J.; Leidich, H.F.; Kugler, T.R.
1996-01-01
This study examines the application of laser ablation to the characterization and decontamination of painted and unpainted concrete and metal surfaces that are typical of many facilities within the US Department of Energy complex. The utility of this promising technology is reviewed and the essential requirements for efficient ablation extracted. Recent data obtained on the ablation of painted steel surfaces and concrete are presented. The affects of beam irradiance, ablation speed and efficiency, and characteristics of the aerosol effluent are discussed. Characterization of the ablated components of the surface offers the ability of concurrent determination of the level of contamination. This concept can be applied online where the ablation endpoint can be determined. A conceptual system for the characterization and decontamination of surfaces is proposed
International Nuclear Information System (INIS)
Satoh, Daiki
2012-01-01
CDE in the title developed by Japan Atomic Energy Agency (JAEA) is explained for its use to support the cleaning work of the environment contaminated by the Fukushima Daiichi Nuclear Power Plant Accident (Mar. 11, 2011). With this CDE software (available at http://nsed.jaea.go.jp/josen, from Nov. 2, 2011), the effect of decontamination schedule/work can be evaluable rapidly and accurately by calculating the ambient dose rates before and after the work. Access number to the CDE site until Jan., 2012, amounts to 402, for the purposes of ambient dose assessment (20%), planning of decontamination (15%), study/investigation (15%), etc. The system software is operable in Microsoft Excel with Graphical User Interface (GUI) described by VBA (Visual Basic for Applications). To be inputted in CDE are the map of the region subjected to decontamination, data of surface contamination density and of decontamination coefficients for the area relief, all of which are available through the internet and actual measurement, which is then followed by output as tables and figures of distribution of the ambient dose rate before and after the work, and of the rate reduction coefficient. Radiation subjected to calculation is from radiocesium ( 134 Cs and 137 Cs). When the software is compared for its accuracy with those by previous software Particle and Heavy Ion Transport Code System (PHITS) and by actual measurement, their results all show a virtually satisfactory agreement, and the time necessary for calculation is over several-ten hours in PHITS, and within about 10 seconds, in CDE. Updated information of CDE is available at the above mentioned site and twitter.com/JAEA_nsed. (T.T.)
Decontamination in the Republic of Belarus
International Nuclear Information System (INIS)
Antsipov, G.V.; Matveenko, S.A.; Mirkhaidarov, A.Kh.
2002-01-01
To continue the decontamination work in the Republic of Belarus, which was carried out by the military troops, the state specialized enterprises were formed in Gomel and Mogilev in 1991. The organization and regulations were developed inside the country: instructions, rules, radiological and hygienic criteria and norms. The enterprises concentrated on decontamination of the most socially significant facilities: kindergartens, schools, medical institutions and industrial enterprises. During 9 years Gomel State Specialized Enterprise 'Polessje' decontaminated 130 kindergartens, schools and hospitals. The total decontaminated area was 450 000 m 2 . The ventilation systems and equipment at 27 industrial enterprises in Gomel were decontaminated. The practical decontamination methods for areas, buildings, roofs, industrial equipment, ventilation systems were developed and tested. The special rules for handling wastes contaminated with Cs were elaborated. The paper analyzes and sums up the acquired experience which is important for implementation of rehabilitation programs and improvement of decontamination methods. (author)
Energy Technology Data Exchange (ETDEWEB)
Bayrakal, Suna [Iowa State Univ., Ames, IA (United States)
1993-09-30
Radioactive metal waste makes up a significant portion of the waste currently being sent for disposal. Recovery of this metal as a valuable resource is possible through the use of decontamination technologies. Through the development and use of expert systems a comparison can be made of laser decontamination, a technology currently under development at Ames Laboratory, with currently available decontamination technologies for applicability to the types of metal waste being generated and the effectiveness of these versus simply disposing of the waste. These technologies can be technically and economically evaluated by the use of expert systems techniques to provide a waste management decision making tool that generates, given an identified metal waste, waste management recommendations. The user enters waste characteristic information as input and the system then recommends decontamination technologies, determines residual contamination levels and possible waste management strategies, carries out a cost analysis and then ranks, according to cost, the possibilities for management of the waste. The expert system was developed using information from literature and personnel experienced in the use of decontamination technologies and requires validation by human experts and assignment of confidence factors to the knowledge represented within.
International Nuclear Information System (INIS)
Bayrakal, S.
1993-01-01
Radioactive metal waste makes up a significant portion of the waste currently being sent for disposal. Recovery of this metal as a valuable resource is possible through the use of decontamination technologies. Through the development and use of expert systems a comparison can be made of laser decontamination, a technology currently under development at Ames Laboratory, with currently available decontamination technologies for applicability to the types of metal waste being generated and the effectiveness of these versus simply disposing of the waste. These technologies can be technically and economically evaluated by the use of expert systems techniques to provide a waste management decision making tool that generates, given an identified metal waste, waste management recommendations. The user enters waste characteristic information as input and the system then recommends decontamination technologies, determines residual contamination levels and possible waste management strategies, carries out a cost analysis and then ranks, according to cost, the possibilities for management of the waste. The expert system was developed using information from literature and personnel experienced in the use of decontamination technologies and requires validation by human experts and assignment of confidence factors to the knowledge represented within
Directory of Open Access Journals (Sweden)
Chiman Saeidi
2015-06-01
Full Text Available Background & objective: Mercury is a toxic and bio-accumulative pollutant that has adverse effects on environmental and human health. There have been a number of attempts to regulate mercury emissions tothe atmosphere. Silver nanoparticles are a number of materials that have highly potential to absorb mercury and formation of mercury amalgam.The aim of this study is removal of mercury vapors in the dental clinic using a n a ir cleaning system based on silver nanoparticles. Methods: In this study, silver nanoparticles coated on the bed of foam and chemical and structural properties were determined using a number of methods such as UV-VIS-NIR spectroscopy and Scanning Electron Microscope (SEM connected the X-ray Emission Spectroscopy Energy (EDS. The a ir cleaning system efficiency to remove of the mercury vapor in simulated conditions in the laboratory and real conditions in the dental clinicwere measured by Cold Vapor Atomic Absorption Spectroscopy (CVAAS. Results: The images of SEM, showed that average sizeof silver nanoparticles in colloidal solution was ∼ 30nm and distribution of silver nanoparticles coated on foam was good. EDS spectrum confirmed associated the presence of silver nanoparticles coated on foam. The significantly difference observed between the concentration of mercury vapor in the off state (9.43 ± 0.342 μg.m-3 and on state (0.51 ± 0.031μg.m-3 of the a ir cleaning system. The mercury vapor removal efficiencyof the a ir cleaning system was calculated 95%. Conclusion : The air cleaning system based on foam coated by silver nanoparticles, undertaken to provide the advantages such as use facilitating, highly efficient operational capacity and cost effective, have highly sufficiency to remove mercury vapor from dental clinics.
International Nuclear Information System (INIS)
Xu, Yun-Chao; Chen, Qun
2013-01-01
The vapor-compression refrigeration systems have been one of the essential energy conversion systems for humankind and exhausting huge amounts of energy nowadays. Surrounding the energy efficiency promotion of the systems, there are lots of effectual optimization methods but mainly relied on engineering experience and computer simulations rather than theoretical analysis due to the complex and vague physical essence. We attempt to propose a theoretical global optimization method based on in-depth physical analysis for the involved physical processes, i.e. heat transfer analysis for condenser and evaporator, through introducing the entransy theory and thermodynamic analysis for compressor and expansion valve. The integration of heat transfer and thermodynamic analyses forms the overall physical optimization model for the systems to describe the relation between all the unknown parameters and known conditions, which makes theoretical global optimization possible. With the aid of the mathematical conditional extremum solutions, an optimization equation group and the optimal configuration of all the unknown parameters are analytically obtained. Eventually, via the optimization of a typical vapor-compression refrigeration system with various working conditions to minimize the total heat transfer area of heat exchangers, the validity and superior of the newly proposed optimization method is proved. - Highlights: • A global optimization method for vapor-compression systems is proposed. • Integrating heat transfer and thermodynamic analyses forms the optimization model. • A mathematical relation between design parameters and requirements is derived. • Entransy dissipation is introduced into heat transfer analysis. • The validity of the method is proved via optimization of practical cases
Enzymatic Decontamination of Chemical Warfare Agents
National Research Council Canada - National Science Library
Raushel, Frank
2000-01-01
The primary objective of this research program is the development of a versatile enzyme-based system that is fully optimized for the decontamination, destruction, and detection of know chemical warfare agents...
Separations canyon decontamination facilities
International Nuclear Information System (INIS)
Hershey, J.H.
1975-01-01
Highly radioactive process equipment is decontaminated at the Savannah River Plant in specially equipped areas of the separations canyon building so that direct mechanical repairs or alterations can be made. Using these facilities it is possible to decontaminate and repair equipment such as 10- x 11-ft storage tanks, 8- x 8-ft batch evaporator pots and columns, 40-in. Bird centrifuges, canyon pumps and agitators, and various canyon piping systems or ''jumpers.'' For example, centrifuge or evaporator pots can be decontaminated and rebuilt for about 60 percent of the 1974 replacement cost. The combined facilities can decontaminate and repair 6 to 10 pieces of major equipment per year. Decontamination time varies with type of equipment and radioactivity levels encountered
Separations canyon decontamination facilities
International Nuclear Information System (INIS)
Hershey, J.H.
1975-05-01
Highly radioactive process equipment is decontaminated at the Savannah River Plant in specially equipped areas of the separations canyon buildings so that direct mechanical repairs or alterations can be made. Using these facilities it is possible to decontaminate and repair equipment such as 10- x 11-ft storage tanks, 8- x 8-ft batch evaporator pots and columns, 40-in. Bird centrifuges, canyon pumps and agitators, and various canyon piping systems or ''jumpers.'' For example, centrifuge or evaporator pots can be decontaminated and rebuilt for about 60 percent of the 1974 replacement cost. The combined facilities can decontaminate and repair 6 to 10 pieces of major equipment per year. Decontamination time varies with type of equipment and radioactivity levels encountered. (U.S.)
Energy Technology Data Exchange (ETDEWEB)
Chen, Xi; Chen, Qingyan [National Air Transport Center of Excellence for Research in the Intermodal Transport Environment (RITE), School of Mechanical Engineering, Purdue University, 585 Purdue Mall, West Lafayette, IN 47905 (United States)
2010-09-15
Effective decontamination is crucial if an airliner cabin is contaminated by biological contaminants, such as infectious disease viruses or intentionally released biological agents. This study used computational fluid dynamics (CFD) method as a tool and vaporized hydrogen peroxide (VHP) as an exemplary decontaminant and Geobacillus stearothermophilus spores as a simulant contaminant to investigate three VHP delivery methods for sterilizing two different airliner cabins. The CFD first determined the airflow and the transient distributions of the contaminant and decontaminant in cabins. Auxiliary equations were implemented into the CFD model for evaluating efficacy of the sterilization process. The improved CFD model was validated by the measured airflow and simulated contaminant distributions obtained from a cabin mockup and the measured efficacy data from the literature. The three decontaminant delivery methods were (1) to supply the mixed VHP and air through the environmental control system of a cabin, (2) to send mixed VHP and air through a front door and to extract them from a back door of a cabin, and (3) to send directly VHP to a cabin and enhance the mixing with air in the cabin by fans. The two air cabins studied were a single-aisle and a twin-aisle airliner one. The results show that the second decontaminant delivery method (displacement method) was the best because the VHP distributions in the cabins were most uniform, the sterilization time was moderate, and the corrosion risk was low. The method displaced the existing air by the air/disinfectant solution, rather than dispersive mixing as the other two methods. (author)
Properties and solidification of decontamination wastes
International Nuclear Information System (INIS)
Davis, M.S.; Piciulo, P.L.; Bowerman, B.S.; Adams, J.W.; Milian, L.
1983-01-01
LWRs will require one or more chemical decontaminations to achieve their designed lifetimes. Primary system decontamination is designed to lower radiation fields in areas where plant maintenance personnel must work. Chemical decontamination methods are either hard (concentrated chemicals, approximately 5 to 25 weight percent) or soft (dilute chemicals less than 1 percent by weight). These methods may have different chemical reagents, some tailor-made to the crud composition and many methods are and will be proprietary. One factor common to most commercially available processes is the presence of organic acids and chelates. These types of organic reagents are known to enhance the migration of radionuclides after disposal in a shallow land burial site. The NRC sponsors two programs at Brookhaven National Laboratory that are concerned with the management of decontamination wastes which will be generated by the full system decontamination of LWRs. These two programs focus on potential methods for degrading or converting decontamination wastes to more acceptable forms prior to disposal and the impact of disposing of solidified decontamination wastes. The results of the solidification of simulated decontamination resin wastes will be presented. Recent results on combustion of simulated decontamintion wastes will be described and procedures for evaluating the release of decontamination reagents from solidified wastes will be summarized
Development of Personal Decontamination System Final Report CRADA No. TC-02078-04
Energy Technology Data Exchange (ETDEWEB)
Smith, W. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); O' Dell, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)
2017-09-27
This was a collaborative effort between The Regents of the University of California, Lawrence Livermore National Laboratory (LLNL) and O’Dell Engineering, Ltd. (O’Dell) to develop an improved low-cost personal decontamination system for Toxic Industrial Chemicals (TICs) and chemical agents. The significant change to the project was that COTS (Commercial Off-the Shelf Components) were identified that performed as well, or better than, the proprietary materials created and tested as part of this CRADA. These COTS components were combined to create a new LPDS (low-cost personal decontamination system) that met all specifications.
Methodology for the evaluation of decontaminant drugs at in vitro systems
International Nuclear Information System (INIS)
Fernandez de Giorgi, Cristina; Dubner, Diana; Gomez Parada, Ines
1987-01-01
An experimental system was developed in order to facilitate hte study of the action of decontaminant drugs in hepatic tissue. Three stages are distinguished: 1) The isolation and the hepatocytes culture in the presence of a chelant agent. 2) The obtainment of the soluble cytoplasmic fraction and its chromatographyc analysis. 3) The comparison of the behaviour of the chelant agent in in vivo and in vitro of the mentioned fraction. 144 CeCl was employed as a radionuclide and DTPA CaNa 3 as a decontaminant agent. The preliminary results of the mechanism of action of the decontaminant obtained by chromatography shows a different distribution of the radionuclide between compounds of high and low molecular weight, in the hepatocytes incubated in the presence of the chelant concerning the controls. (M.E.L.) [es
A simple and feasible method of effectiveness evaluation on radioactive decontamination action
International Nuclear Information System (INIS)
Chen Lin; Geng Xiaobing; Sun Jian; Wang Jihong; Guo Lijun
2012-01-01
Radioactive decontamination is a vital task in nuclear emergency response. The assessment of decontamination effectiveness is of great importance to decision-making. An index system for effectiveness evaluation of radioactive decontamination action in nuclear emergency response is produced. A method of decontamination effectiveness evaluation based on analytic hierarchy process and fuzzy comprehensive evaluation is presented. Index weights are determined through analytic hierarchy process. And scores of objects in each hierarchy are judged by fuzzy comprehensive evaluation. Then comprehensive effectiveness of the top object can be obtained, which can offer a basis for decision-making of decontamination action. (authors)
Magnetite Dissolution Performance of HYBRID-II Decontamination Process
International Nuclear Information System (INIS)
Kim, Seonbyeong; Lee, Woosung; Won, Huijun; Moon, Jeikwon; Choi, Wangkyu
2014-01-01
In this study, we conducted the magnetite dissolution performance test of HYBRID-II (Hydrazine Based Reductive metal Ion Decontamination with sulfuric acid) as a part of decontamination process development. Decontamination performance of HYBRID process was successfully tested with the results of the acceptable decontamination factor (DF) in the previous study. While following-up studies such as the decomposition of the post-decontamination HYBRID solution and corrosion compatibility on the substrate metals of the target reactor coolant system have been continued, we also seek for an alternate version of HYBRID process suitable especially for decommissioning. Inspired by the relationship between the radius of reacting ion and the reactivity, we replaced the nitrate ion in HYBRID with bigger sulfate ion to accommodate the dissolution reaction and named HYBRID-II process. As a preliminary step for the decontamination performance, we tested the magnetite dissolution performance of developing HYBRID-II process and compared the results with those of HYBRID process. HYBRID process developed previously is known have the acceptable decontamination performance, but the relatively larger volume of secondary waste induced by anion exchange resin to treat nitrate ion is the one of the problems related in the development of HYBRID process to be applicable. Therefore we alternatively devised HYBRID-II process using sulfuric acid and tested its dissolution of magnetite in numerous conditions. From the results shown in this study, we can conclude that HYBRID-II process improves the decontamination performance and potentially reduces the volume of secondary waste. Rigorous tests with metal oxide coupons obtained from reactor coolant system will be followed to prove the robustness of HYBRID-II process in the future
CB decontamination for first responders
Energy Technology Data Exchange (ETDEWEB)
Mayer, M.D.G.; Purdon, J.G.; Burczyk, A. [Defence Research and Development Canada Suffield, Ralston, AB (Canada)
2006-07-01
The Universal Containment System (UCS) is designed to contain, mitigate and decontaminate chemical, biological and radiological warfare agents. The UCS consists of a lightweight, tent-like enclosure filled with a water-based surface decontaminating foam (SDF). The Canadian government funded a project to advance the understanding of the behaviour of the UCS. This paper described the success of the project as well as the technological advances in the UCS formulation and equipment. Vapour desorption experiments were conducted in which SDF was applied onto 12 surfaces found in a typical office environment. Both mustard and nerve agent were studied on the test surfaces. Both scrubbing and non-scrubbing decontamination methods were tested. SDF effectively decontaminated the non-porous substances, particularly when the scrubbing procedure was used. Results were more complicated for the non-porous samples. A dye added to the agent was useful for determining the fate of the agent. Liquid phase studies were conducted in which the reaction between SDF and various agents were studied in the liquid phase in order to estimate the rate of reaction, the stoichiometry and the reaction products formed. Both SDF and the commercial decontamination agent CASCAD were found to effectively kill 100 per cent of anthrax spores. The significance of this project to first responders was considerable. Changes to the formulation and equipment of UCS will increase its usefulness and safety. Users will also have a better knowledge of the amount of decontamination needed for complete effectiveness in specific situations. Recommendations have been made for use of the product on a range of indoor surfaces. Field trials have shown the blast mitigation and agent decontamination ability of the foam under explosive situations. 15 refs., 4 tabs.
Development of decontamination methods
International Nuclear Information System (INIS)
Kunze, S.; Dippel, T.; Hentschel, D.
1976-01-01
PVC floorings, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination. Rubber floorings, fabricated by chemical reactions between polymers, vulcanization materials and fillers, show decontamination results depending definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontaminate. Increasing contents of hydrophilic filler cause a fall off in the decontamination results. The decontamination effectiveness and the homogenity of cleaning pastes based on hydrochloric acid, nitric acid, titanium oxide and polyethylene powders is strongly depended on the content of hydrochloric acid. Reduction of the content of this component to less than 2 w/O remains the effectiveness unchanged only if the titanium oxide-polyethylene powder mixture is substituted by a high density, highly surface active powder material. This type of paste containing no hydrochloric acid shows nearly the same decontamination effectiveness as standard pickling pastes containing about 30% hydrochlorid acid. Properly prepared salt powder turn out to be easily and successfully applied to metal surfaces by a flame spray technique. The thin layer of molten salts is a very effective decontamination to samples contaminated in the primary loop of a PWR. (orig.) [de
Pipe Decontamination Involving String-Foam Circulation
International Nuclear Information System (INIS)
Turchet, J.P.; Estienne, G.; Fournel, B.
2002-01-01
Foam applications number for nuclear decontamination purposes has recently increased. The major advantage of foam decontamination is the reduction of secondary liquid wastes volumes. Among foam applications, we focus on foam circulation in contaminated equipment. Dynamic properties of the system ensures an homogeneous and rapid effect of the foam bed-drifted chemical reagents present in the liquid phase. This paper describes a new approach of foam decontamination for pipes. It is based on an alternated air and foam injections. We called it 'string-foam circulation'. A further reduction of liquid wastes is achieved compared to continuous foam. Secondly, total pressure loss along the pipe is controlled by the total foam length in the pipe. It is thus possible to clean longer pipes keeping the pressure under atmospheric pressure value. This ensures the non dispersion of contamination. This study describes experimental results obtained with a neutral foam as well with an acid foam on a 130 m long loop. Finally, the decontamination of a 44 meters pipe is presented. (authors)
Numerical analysis of the in-well vapor-stripping system demonstration at Edwards Air Force Base
International Nuclear Information System (INIS)
White, M.D.; Gilmore, T.J.
1996-10-01
Numerical simulations, with the Subsurface Transport Over Multiple Phases (STOMP) simulator, were applied to the field demonstration of an in-well vapor-stripping system at Edwards Air Force Base (AFB), near Mojave, California. The demonstration field site on the Edwards AFB was previously contaminated from traversing groundwater that was contained a varied composition of volatile organic compounds (VOCs), which primarily includes trichloroethylene (TCE). Contaminant TCE originated from surface basin that had been used to collect runoff during the cleaning of experimental rocket powered planes in the 1960s and 1970s. This report documents those simulations and associated numerical analyses. A companion report documents the in- well vapor-stripping demonstration from a field perspective
Research and development for decontamination system of spent resin in Hanbit Nuclear Power Plant
Energy Technology Data Exchange (ETDEWEB)
Sung, Gi Hong [Dept. of Nuclear Engineering, Chosun University, Gwangju (Korea, Republic of)
2015-12-15
When reactor coolant leaks occur due to cracks of a steam generator tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000-7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In
Research and development for decontamination system of spent resin in Hanbit Nuclear Power Plant
International Nuclear Information System (INIS)
Sung, Gi Hong
2015-01-01
When reactor coolant leaks occur due to cracks of a steam generator tube, radioactive materials contained in the primary cooling water in nuclear power plant are forced out toward the secondary systems. At this time the secondary water purification resin in the ion exchange resin tower of the steam generator blowdown system is contaminated by the radioactivity of the leaked radioactive materials, so we pack this in special containers and store temporarily because we could not dispose it by ourselves. If steam generator tube leakage occurs, it produces contaminated spent resins annually about 5,000-7,000 liters. This may increase the amount of nuclear waste productions, a disposal working cost and a unit price of generating electricity in the plant. For this reasons, it is required to develop a decontamination process technique for reducing the radioactive level of these resins enough to handle by the self-disposal method. In this research, First, Investigated the structure and properties of the ion exchange resin used in a steam generator blowdown system. Second, Checked for a occurrence status of contaminated spent resin and a disposal technology. Third, identified the chemical characteristics of the waste radionuclides of the spent resin, and examined ionic bonding and separation mechanism of radioactive nuclear species and a spent resin. Finally, we carried out the decontamination experiment using chemicals, ultrasound, microbubbles, supercritical carbon dioxide to process these spent resin. In the case of the spent resin decontamination method using chemicals, the higher the concentration of the drug decontamination efficiency was higher. In the ultrasound method, foreign matter of the spent resin was removed and was found that the level of radioactivity is below of the MDA. In the microbubbles method, we found that the concentration of the radioactivity decreased after the experiment, so it can be used to the decontamination process of the spent resin. In
International Nuclear Information System (INIS)
1983-07-01
This Code of Practice covers: (a) the decontamination of plant items, buildings and associated equipment; (b) decontamination of protective clothing; (c) simple personal decontamination; and (d) the basic mechanisms of contamination and their influence on decontaminability. (author)
International Nuclear Information System (INIS)
Anklam, T.M.; Berzins, L.V.; Braun, D.G.; Haynam, C.; McClelland, M.A.; Meier, T.
1994-10-01
Lawrence Livermore National Laboratory is developing sensors and controls to improve and extend electron beam materials processing technology to alloy systems with constituents of widely varying vapor pressure. The approach under development involves using tunable lasers to measure the density and composition of the vapor plume. A laser based vaporizer control system for vaporization of a uranium-iron alloy has been previously demonstrated in multi-hundred hour, high rate vaporization experiments at LLNL. This paper reviews the design and performance of the uranium vaporization sensor and control system and discusses the extension of the technology to monitoring of uranium vaporization. Data is presented from an experiment in which titanium wire was fed into a molten niobium pool. Laser data is compared to deposited film composition and film cross sections. Finally, the potential for using this technique for composition control in melting applications is discussed
Monte-Carlo simulation of complex vapor-transport systems for RIB applications
International Nuclear Information System (INIS)
Zhang, Y.; Alton, G.D.
2005-01-01
In order to minimize decay losses of short-lived radioactive species at ISOL based RIB facilities, effusive-flow particle transit times between target and ion source must be as short as practically achievable. A Monte-Carlo code has been developed for simulating the effusive-flow of neutral particles through vapor-transport systems independent of materials of construction. The code provides average distance traveled and time information associated with the transit of individual particles through a system. It offers a cost effective and accurate means for arriving at vapor-transport system designs. In this report, the code will be described and results obtained by its use in evaluating several prototype vapor-transport systems using specular reflection, cosine and isotropic particle re-emission about the normal to the surface models following adsorption. Simulation results obtained with an isotropic distribution are in close agreement with experimental measurements of the properties of prototype vapor-transport systems fabricated at the Holifield Radioactive Ion Beam Facility
Some remarks about decontamination
International Nuclear Information System (INIS)
Bertini, A.
1990-01-01
Decontamination in itself is not the elimination of a problem, but corresponds to move that problem from one place to another. It is beneficial only if the contamination is less of a nuisance when moved to the ''other place''. Therefore any prospective decontamination process is to be considered essentially in terms of cost-benefit, and in particular in terms of reducing the burden on the waste management systems. The paper is not intended to deal with and to review critically the technical aspects of the various decontamination processes which are currently available. Its aim is to call the attention of those who may be faced with the problem of large-scale decontamination, so that this operation is carried out after all practical aspects have been examined. (author)
PWR decontamination feasibility study
Energy Technology Data Exchange (ETDEWEB)
Silliman, P.L.
1978-12-18
The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of Indian Point 1 are well suited for use in demonstrations.
PWR decontamination feasibility study
International Nuclear Information System (INIS)
Silliman, P.L.
1978-01-01
The decontamination work which has been accomplished is reviewed and it is concluded that it is worthwhile to investigate further four methods for decontamination for future demonstration. These are: dilute chemical; single stage strong chemical; redox processes; and redox/chemical in combination. Laboratory work is recommended to define the agents and processes for demonstration and to determine the effect of the solvents on PWR materials. The feasibility of Indian Point 1 for decontamination demonstrations is discussed, and it is shown that the system components of Indian Point 1 are well suited for use in demonstrations
Development of strippable gel for surface decontamination applications
International Nuclear Information System (INIS)
Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.
2015-07-01
Strippable gels are an attractive option for decontamination of surfaces particularly when materials are to be reused after decontamination. The process in general results in good decontamination performance with minimal secondary waste generation. This paper reports on development of strippable gel formulation using polyvinyl alcohol as the gel former. Peeling behavior of the gel film improved when glycerol was used as plasticizer. Incorporation of decontaminating agents is essential for the gel to be effective, so a number of decontaminating agents were screened based on their miscibility with the gel, smooth peeling, and good decontamination performance. Based on this study, a strippable gel, ‘INDIGEL’ was formulated as a potential candidate for surface decontamination applications. Extensive trials on evaluation of decontamination performance of Indigel were done on simulated surfaces like stainless steel tray, stainless steel fume hood, PVC floor, granite and ceramic table tops. Results show that Indigel is highly effective for decontamination of surfaces contaminated with all types of radionuclides. Simplicity of its use coupled with good decontamination ability will find application in nuclear and other chemical industries. (author)
Improvement in ultraviolet based decontamination rate using meta-materials
Enaki, Nicolae A.; Bazgan, Sergiu; Ciobanu, Nellu; Turcan, Marina; Paslari, Tatiana; Ristoscu, Carmen; Vaseashta, Ashok; Mihailescu, Ion N.
2017-09-01
We propose a method of decontamination using photon-crystals consisting of microspheres and fiber optics structures with various geometries. The efficient decontamination using the surface of the evanescent zone of meta-materials opens a new perspective in the decontamination procedures. We propose different topological structures of meta-materials to increase the contact surface of UV radiation with contaminated liquid. Recent observation of the trapping of dielectric particles along the fibers help us propose a new perspective on the new possibilities to trap the viruses, bacteria and other microorganisms from liquids, in this special zone, where the effective UV coherent Raman decontamination becomes possible. The nonlinear theory of the excitation of vibration modes of bio-molecule of viruses and bacteria is revised, taking into consideration the bimodal coherent states in coherent Raman excitation of biomolecules.
International Nuclear Information System (INIS)
1980-05-01
The staff has considered the environmental impact and economic costs of the proposed primary cooling system chemical decontamination at Dresden Nuclear Power Station, Unit 1. The staff has focused this statement on the occupational radiation exposure associated with the proposed Unit 1 decontamination program, on alternatives to chemical decontamination, and on the environmental impact of the disposal of the solid radioactive waste generated by this decontamination. The staff has concluded that the proposed decontamination will not significantly affect the quality of the human environment. Furthermore, any impacts from the decontamination program are outweighed by its benefits. 2 figs., 7 tabs
NRC regulations and positions concerning decontamination
International Nuclear Information System (INIS)
McCracken, C.
1982-09-01
The U.S. Nuclear Regulatory Commission encourages the use of decontamination to reduce man-rem exposure. The Commission feels that there are several processes developed to the point where soft decontamination can be applied to an entire plant in the near future. A utility can do a decontamination under its own licence without coming in for regulatory review if the process does not involve a change in technical specifications for the plant or does not involve unreviewed safety questions. Prior verbal notification is required for some steam generator secondary side cleaning or for decontamination of individual components that have not been removed from the reactor using chemicals not normally added to the reactor coolant. Prior written notification is required for steam generator secondary side crevice cleaning or sludge removal at a dented unit, or for chemical decontamination of reactor coolant systems or safety-related systems using chemicals not normally added to the coolant
Chemical Decontamination at Browns Ferry Unit 1
International Nuclear Information System (INIS)
Hartwig, Ed; Reid, Richard
2003-01-01
In May, 2002, the Tennessee Valley Authority's (TVA) Board of Directors approved the recovery and restart of Unit 1 at Browns Ferry Nuclear Station. As an initial step in the site characterization and restart feasibility review, a majority of the primary reactor circuit was chemically decontaminated. Close cooperation between TVA and vendor personnel resulted in project completion ahead of schedule with outstanding results. The final average decontamination factors were excellent, and the final dose rates were very low, with contact readings on most points between one and three mRem/hr. In addition to allowing TVA to do a complete and thorough job of determining the feasibility of the Unit 1 restart, the decontamination effort will greatly reduce personnel exposure during plant recovery, both whole body exposure to gamma radiation and airborne exposure during pipe replacement efforts. The implementation of lessons learned from previous decontamination work performed at Browns Ferry, as well as decontamination efforts at other plants aided greatly in the success. Specific items of note are: (1) The initial leak check of the temporary decontamination system should include ancillary systems such as the spent resin system, as well as the main circulation loop. This could save time and dose exposure if leaks are discovered before the use of such systems is required. (2) Due to the quick turnaround time from the award of contract, a vendor representative was onsite early in the project to help with engineering efforts and procedures. This aided greatly in completing preparations for the decontamination. (3) The work was performed under a single maintenance activity. This resulted in great craft and plant support. (4) The constant coverage by the site's decontamination flush directors provided timely plant support and interface. (5) The FPC system isolation and back flushing to prevent residual chemicals from being left in the FPC system should have been addressed in more
Model for analyzing decontamination process systems
International Nuclear Information System (INIS)
Boykin, R.F.; Rolland, C.W.
1979-06-01
Selection of equipment and the design of a new facility in light of minimizing cost and maximizing capacity, is a problem managers face many times in the operations of a manufacturing organization. This paper deals with the actual analysis of equipment facility design for a decontamination operation. Discussions on the selection method of the equipment and the development of the facility design criteria are presented along with insight into the problems encountered in the equipment analysis for a new decontamination facility. The presentation also includes a review of the transition from the old facility into the new facility and the process used to minimize the cost and conveyance problems of the transition
Anthrax Sampling and Decontamination: Technology Trade-Offs
Energy Technology Data Exchange (ETDEWEB)
Price, Phillip N.; Hamachi, Kristina; McWilliams, Jennifer; Sohn, Michael D.
2008-09-12
The goal of this project was to answer the following questions concerning response to a future anthrax release (or suspected release) in a building: 1. Based on past experience, what rules of thumb can be determined concerning: (a) the amount of sampling that may be needed to determine the extent of contamination within a given building; (b) what portions of a building should be sampled; (c) the cost per square foot to decontaminate a given type of building using a given method; (d) the time required to prepare for, and perform, decontamination; (e) the effectiveness of a given decontamination method in a given type of building? 2. Based on past experience, what resources will be spent on evaluating the extent of contamination, performing decontamination, and assessing the effectiveness of the decontamination in abuilding of a given type and size? 3. What are the trade-offs between cost, time, and effectiveness for the various sampling plans, sampling methods, and decontamination methods that have been used in the past?
Testing of a portable ultrahigh pressure water decontamination system (UHPWDS)
International Nuclear Information System (INIS)
Lovell, A.; Dahlby, J.
1996-02-01
This report describes the tests done with a portable ultrahigh pressure water decontamination system (UHPWDS) on highly radioactively contaminated surfaces. A small unit was purchased, modified, and used for in-situ decontamination to change the waste level of the contaminated box from transuranic (TRU) waste to low- level waste (LLW). Low-level waste is less costly by as much as a factor of five or more if compared with TRU waste when handling, storage, and disposal are considered. The portable unit we tested is commercially available and requires minimal utilities for operation. We describe the UHPWDS unit itself, a procedure for its use, the results of the testing we did, and conclusions including positive and negative aspects of the UHPWDS
Recent developments in chemical decontamination technology
Energy Technology Data Exchange (ETDEWEB)
Wood, C.J. [Electric Power Research Institute, Palo Alto, CA (United States)
1995-03-01
Chemical decontamination of parts of reactor coolant systems is a mature technology, used routinely in many BWR plants, but less frequently in PWRs. This paper reviews recent developments in the technology - corrosion minimization, waste processing and full system decontamination, including the fuel. Earlier work was described in an extensive review published in 1990.
Decontamination and Decommissioning Equipment Tracking System (DDETS)
International Nuclear Information System (INIS)
Cook, S.
1994-07-01
At the request of the Department of Energy (DOE)(EM-50), the Scientific Computing Unit developed a prototype system to track information and data relevant to equipment and tooling removed during decontamination and decommissioning activities. The DDETS proof-of-concept tracking system utilizes a one-dimensional (1D) and two-dimensional (2D) bar coding technology to retain and track information such as identification number, manufacturer, requisition information, and various contaminant information, etc. The information is encoded in a bar code, printed on a label and can be attached to corresponding equipment. The DDETS was developed using a proven relational database management system which allows the addition, modification, printing, and deletion of data. In addition, communication interfaces with bar code printers and bar code readers were developed. Additional features of the system include: (a) Four different reports available for the user (REAPS, transaction, and two inventory), (b) Remote automated inventory tracking capabilities, (c) Remote automated inventory tracking capability (2D bar codes allow equipment to be scanned/tracked without being linked to the DDETS database), (d) Edit, update, delete, and query capabilities, (e) On-line bar code label printing utility (data from 2D bar codes can be scanned directly into the data base simplifying data entry), and (f) Automated data backup utility. Compatibility with the Reportable Excess Automated Property System (REAPS) to upload data from DDETS is planned
[Decontamination of chemical and biological warfare agents].
Seto, Yasuo
2009-01-01
Chemical and biological warfare agents (CBWA's) are diverse in nature; volatile acute low-molecular-weight toxic compounds, chemical warfare agents (CWA's, gaseous choking and blood agents, volatile nerve gases and blister agents, nonvolatile vomit agents and lacrymators), biological toxins (nonvolatile low-molecular-weight toxins, proteinous toxins) and microbes (bacteria, viruses, rickettsiae). In the consequence management against chemical and biological terrorism, speedy decontamination of victims, facilities and equipment is required for the minimization of the damage. In the present situation, washing victims and contaminated materials with large volumes of water is the basic way, and additionally hypochlorite salt solution is used for decomposition of CWA's. However, it still remains unsolved how to dispose large volumes of waste water, and the decontamination reagents have serious limitation of high toxicity, despoiling nature against the environments, long finishing time and non-durability in effective decontamination. Namely, the existing decontamination system is not effective, nonspecifically affecting the surrounding non-target materials. Therefore, it is the urgent matter to build up the usable decontamination system surpassing the present technologies. The symposiast presents the on-going joint project of research and development of the novel decontamination system against CBWA's, in the purpose of realizing nontoxic, fast, specific, effective and economical terrorism on-site decontamination. The projects consists of (1) establishment of the decontamination evaluation methods and verification of the existing technologies and adaptation of bacterial organophosphorus hydrolase, (2) development of adsorptive elimination technologies using molecular recognition tools, and (4) development of deactivation technologies using photocatalysis.
Estimating evaporative vapor generation from automobiles based on parking activities
International Nuclear Information System (INIS)
Dong, Xinyi; Tschantz, Michael; Fu, Joshua S.
2015-01-01
A new approach is proposed to quantify the evaporative vapor generation based on real parking activity data. As compared to the existing methods, two improvements are applied in this new approach to reduce the uncertainties: First, evaporative vapor generation from diurnal parking events is usually calculated based on estimated average parking duration for the whole fleet, while in this study, vapor generation rate is calculated based on parking activities distribution. Second, rather than using the daily temperature gradient, this study uses hourly temperature observations to derive the hourly incremental vapor generation rates. The parking distribution and hourly incremental vapor generation rates are then adopted with Wade–Reddy's equation to estimate the weighted average evaporative generation. We find that hourly incremental rates can better describe the temporal variations of vapor generation, and the weighted vapor generation rate is 5–8% less than calculation without considering parking activity. - Highlights: • We applied real parking distribution data to estimate evaporative vapor generation. • We applied real hourly temperature data to estimate hourly incremental vapor generation rate. • Evaporative emission for Florence is estimated based on parking distribution and hourly rate. - A new approach is proposed to quantify the weighted evaporative vapor generation based on parking distribution with an hourly incremental vapor generation rate
International Nuclear Information System (INIS)
Cristy, G.A.; Jernigan, H.C.
1981-02-01
The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination
Chemical Gel for Surface Decontamination
International Nuclear Information System (INIS)
Jung, Chong Hun; Moon, J. K.; Won, H. J.; Lee, K. W.; Kim, C. K.
2010-01-01
Many chemical decontamination processes operate by immersing components in aggressive chemical solutions. In these applications chemical decontamination technique produce large amounts of radioactive liquid waste. Therefore it is necessary to develop processes using chemical gels instead of chemical solutions, to avoid the well-known disadvantages of chemical decontamination techniques while retaining their high efficiency. Chemical gels decontamination process consists of applying the gel by spraying it onto the surface of large area components (floors, walls, etc) to be decontaminated. The gel adheres to any vertical or complex surface due to their thixotropic properties and operates by dissolving the radioactive deposit, along with a thin layer of the gel support, so that the radioactivity trapped at the surface can be removed. Important aspects of the gels are that small quantities can be used and they show thixitropic properties : liquid during spraying, and solid when stationary, allowing for strong adherence to surfaces. This work investigates the decontamination behaviors of organic-based chemical gel for SS 304 metallic surfaces contaminated with radioactive materials
Schwartz, M D; Hurst, C G; Kirk, M A; Reedy, S J D; Braue, E H
2012-08-01
Rapid decontamination of the skin is the single most important action to prevent dermal absorption of chemical contaminants in persons exposed to chemical warfare agents (CWA) and toxic industrial chemicals (TICs) as a result of accidental or intentional release. Chemicals on the skin may be removed by mechanical means through the use of dry sorbents or water. Recent interest in decontamination systems which both partition contaminants away from the skin and actively neutralize the chemical has led to the development of several reactive decontamination solutions. This article will review the recently FDA-approved Reactive Skin Decontamination Lotion (RSDL) and will summarize the toxicity and efficacy studies conducted to date. Evidence of RSDL's superior performance against vesicant and organophosphorus chemical warfare agents compared to water, bleach, and dry sorbents, suggests that RSDL may have a role in mass human exposure chemical decontamination in both the military and civilian arenas.
Energy Technology Data Exchange (ETDEWEB)
Cristy, G.A.; Jernigan, H.C. (eds.)
1981-02-01
The record of the proceedings of the workshop on environmental decontamination contains twenty-seven presentations. Emphasis is placed upon soil and surface decontamination, the decommissioning of nuclear facilities, and assessments of instrumentation and equipment used in decontamination. (DLS)
Testing and evaluation of eight decontamination chemicals
International Nuclear Information System (INIS)
Demmer, R.
1994-09-01
This report covers experimental work comparing eight different decontamination chemicals. Seven of these chemicals have some novelty, or are not currently in use at the ICPP. The eighth is a common ICPP decontamination reagent used as a baseline for effective comparison. Decontamination factors, waste generation values, and corrosion rates are tabulated for these chemicals. Recommendations are given for effective methods of non-sodium or low-sodium decontamination chemicals. The two most effective chemical for decontamination found in these test were a dilute hydrofluoric and nitric acid (HF/HNO 3 ) mixture and a fluoroboric acid solution. The fluoroboric acid solution (1 molar) was by far the most effective decontamination reagent, but suffered the problem of generating significant final calcine volume. The HF/HNO 3 solution performed a very good decontamination of the SIMCON coupons while generating only small amounts of calcine volume. Concentration variables were also tested, and optimized for these two solutions. Several oxidation/reduction decon chemical systems were also tested. These systems were similar to the TURCO 4502 and TURCO 4521 solutions used for general decontamination at the ICPP. A low sodium alternative, nitric acid/potassium permanganate, to the ''high sodium'' TURCO 4502 was tested extensively, optimized and recommended for general ICPP use. A reductive chemical solution, oxalic acid/nitric acid was also shown to have significant advantages
Evaluation of a dilute chemical decontaminant for pressurized heavy water reactors
International Nuclear Information System (INIS)
Velmurugan, S.; Narasimhan, S.V.; Mathur, P.K.; Venkateswarlu, K.S.
1991-01-01
In this paper a dilute chemical decontamination formulation based on ethylene diamine tetraacetic acid, oxalic acid, and citric acid is evaluated for its efficacy in removing oxide layers in a pressurized heavy water reactor (PHWR). An ion exchange system that is specifically suited for fission product-dominated contamination in a PHWR is suggested for the reagent regeneration stage of the decontamination process. An attempt has been made to understand the redeposition behavior of various isotopes during the decontamination process. The polarographic method of identifying the species formed in the dissolution process is explained. Electrochemical measurements are employed to follow the course of oxide removal during the dissolution process. Scanning electron micrographs of metal coupons before and after the dissolution process exemplify the involvement of base metal in the formation of a ferrous oxalate layer. Material compatibility tests between the decontaminant and carbon steel, Monel-400, and Zircaloy-2 are reported
Skin decontamination: principles and perspectives.
Chan, Heidi P; Zhai, Hongbo; Hui, Xiaoying; Maibach, Howard I
2013-11-01
Skin decontamination is the primary intervention needed in chemical, biological and radiological exposures, involving immediate removal of the contaminant from the skin performed in the most efficient way. The most readily available decontamination system on a practical basis is washing with soap and water or water only. Timely use of flushing with copious amounts of water may physically remove the contaminant. However, this traditional method may not be completely effective, and contaminants left on the skin after traditional washing procedures can have toxic consequences. This article focuses on the principles and practices of skin decontamination.
Chemical decontamination of stainless steel
International Nuclear Information System (INIS)
Onuma, Tsutomu; Akimoto, Hidetoshi
1991-01-01
The present invention concerns a method for chemical decontamination of radioactive metal waste materials contaminated with radioactive materials on the surface, generated in radioactive materials-handling facilities. The invention is comprised of a method of chemical decontamination of stainless steel, characterized by comprising a first process of immersing a stainless steel-based metal waste material contaminated by radioactive materials on the surface in a sulfuric acid solution and second process of immersing in an aqueous solution of sulfuric acid and oxidizing metal salt, in which a portion of the surface of the stainless steel to be decontaminated is polished mechanically to expose a portion of the base material before the above first and second processes. 1 figs., 2 tabs
Decontamination manual of RI handling laboratory
International Nuclear Information System (INIS)
Wadachi, Yoshiki
2004-01-01
Based on experiences in Japan Atomic Energy Research Institute (JAERI), the essential and practical knowledge of radioactive contamination and its decontamination, and the method and procedure of floor decontamination are described for researcher and managing person in charge of handling radioisotopes (RI) in RI handling laboratories. Essential knowledge concerns the uniqueness of solid surface contamination derived from RI half lives and quantities, surface contamination density limit, and mode/mechanism of contamination. The principle of decontamination is a single conduct with recognition of chemical form of the RI under use. As the practical knowledge, there are physical and chemical methods of solid surface decontamination. The latter involves use of inorganic acids, chelaters and surfactants. Removal and replacement of contaminated solid like floor material are often effective. Distribution mapping of surface contamination can be done by measuring the radioactivity in possibly contaminated areas, and is useful for planning of effective decontamination. Floor surface decontamination is for the partial and spread areas of the floor. It is essential to conduct the decontamination with reagent from the highly to less contaminated areas. Skin decontamination with either neutral detergent or titanium oxide is also described. (N.I.)
Chemical decontamination method
International Nuclear Information System (INIS)
Nishiwaki, Hitoshi.
1996-01-01
Metal wastes contaminated by radioactive materials are contained in a rotational decontamination vessel, and the metal wastes are rotated therein while being in contact with a slight amount of a decontamination liquid comprising a mineral acid. As the mineral acid, a mixed acid of nitric acid, hydrochloric acid and fluoric acid is preferably used. Alternatively, chemical decontamination can also be conducted by charging an acid resistant stirring medium in the rotational decontamination vessel. The surface of the metal wastes is uniformly covered by the slight amount of decontamination liquid to dissolve the surface layer. In addition, heat of dissolution generated in this case is accumulated in the inside of the rotational decontamination vessel, the temperature is elevated with no particular heating, thereby enabling to obtain an excellent decontamination effect substantially at the same level as in the case of heating the liquid to 70degC in a conventional immersion decontamination method. Further, although contact areas between the metal wastes and the immersion vessel are difficult to be decontaminated in the immersion decontamination method, all of areas can be dissolved uniformly in the present invention. (T.M.)
Chemical decontamination of metals
International Nuclear Information System (INIS)
Partridge, J.A.; Lerch, R.E.
1979-10-01
A metal decontamination process based upon removal of contamination by treatment with a cerium (IV)-nitric acid solution (or other redox agent in nitric acid) is feasible and highly promising. The technique is effective in dissolving the surface layer of stainless steel. Dissolution rates of approximately 1.5 mils/h were demonstrated with cerium (IV)-nitric acid solutions. Removal of plutonium contamination from stainless steel was demonstrated in laboratory tests, in which activity levels were reduced from greater than 5 x 10 5 counts per minute to nondetectable levels in approximately one hour at 90 0 C. Removal of paint from stainless steel surfaces was also demonstrated. Advantages of this process over other chemical solutions include: (1) The solutions are not high salt systems; therefore, there is potentially less waste generated. (2) Cerium(IV) in nitric acid is a good dissolution agent for plutonium oxide. (3) Regeneration of Ce(IV) during the decontamination is accomplished by electrolysis. (4) The process should be effective for irregularly shaped equipment. (5) It could be effective as a spray or a flow-through system. 13 figures
Decontamination and inspection plan for Phase 3 closure of the 300 area waste acid treatment system
International Nuclear Information System (INIS)
LUKE, S.N.
1999-01-01
This decontamination and inspection plan (DIP) describes decontamination and verification activities in support of Phase 3 closure of the 300 Area Waste Acid Treatment System (WATS). Phase 3 is the third phase of three WATS closure phases. Phase 3 attains clean closure conditions for WATS portions of the 334 and 311 Tank Farms (TF) and the 333 and 303-F Buildings. This DIP also describes designation and management of waste and debris generated during Phase 3 closure activities. Information regarding Phase 1 and Phase 2 for decontamination and verification activities closure can be found in WHC-SD-ENV-AP-001 and HNF-1784, respectively. This DIP is provided as a supplement to the closure plan (DOE/RL-90-11). This DIP provides the documentation for Ecology concurrence with Phase 3 closure methods and activities. This DIP is intended to provide greater detail than is contained in the closure plan to satisfy Ecology Dangerous Waste Regulations, Washington Administrative Code (WAC) 173-303-610 requirement that closure documents describe the methods for removing, transporting, storing, and disposing of all dangerous waste at the unit. The decontamination and verification activities described in this DIP are based on the closure plan and on agreements reached between Ecology and the U.S. Department of Energy, Richland Operations Office (DOE-RL) during Phase 3 closure activity workshops and/or project manager meetings (PMMs)
Hopkins, F B; Gravett, M R; Self, A J; Wang, M; Chua, Hoe-Chee; Hoe-Chee, C; Lee, H S Nancy; Sim, N Lee Hoi; Jones, J T A; Timperley, C M; Riches, J R
2014-08-01
Detailed chemical analysis of solutions used to decontaminate chemical warfare agents can be used to support verification and forensic attribution. Decontamination solutions are amongst the most difficult matrices for chemical analysis because of their corrosive and potentially emulsion-based nature. Consequently, there are relatively few publications that report their detailed chemical analysis. This paper describes the application of modern analytical techniques to the analysis of decontamination solutions following decontamination of the chemical warfare agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). We confirm the formation of N,N-diisopropylformamide and N,N-diisopropylamine following decontamination of VX with hypochlorite-based solution, whereas they were not detected in extracts of hydroxide-based decontamination solutions by nuclear magnetic resonance (NMR) spectroscopy or gas chromatography-mass spectrometry. We report the electron ionisation and chemical ionisation mass spectroscopic details, retention indices, and NMR spectra of N,N-diisopropylformamide and N,N-diisopropylamine, as well as analytical methods suitable for their analysis and identification in solvent extracts and decontamination residues.
Technology for treatment of decontamination products
International Nuclear Information System (INIS)
Kavkhuta, G.A.; Rozdzyalovskaya, L.F.
1994-01-01
The research concerning the methods of management and processing of products generated as the result of post Chernobyl decontamination activities is being carried out by the Institute of Radioecological Problems of Belarus Academy of Science (IRP) in the framework of the Belarus National Programme. The main goal of this work is choice and development of an appropriate system for treatment of the decontamination radwastes, based on currently available information and experimental studies. This paper presents the technological schemes being studied for treating the post-Chernobyl liquid and solid wastes and will also briefly discuss the approach being used to settle a problem on collecting/management of low-level radioactive ash wastes, generated from the use of contaminated fuel
Foam process for application of decontamination agents
International Nuclear Information System (INIS)
Harris, J.M.; Miller, J.R.; Frazier, R.S.; Walter, J.H.
1982-01-01
This paper presents the results and observations of a study performed by the authors to parametrically evaluate the performance characteristics of a foam process for application of decontamination agents. The initial tests were established to assess foam quality. Subsequent tests determined the ability of the foam as a carrier of chemical systems, and established system operating parameters. The technique was then applied in an actual decontamination task to verify effectiveness of these established parameters and to determine decontamination reduction factors. 4 figures, 5 tables
International Nuclear Information System (INIS)
Kutlakhmedov, Y.; Zezina, N.; Micheev, A.; Jouve, A.; Perepelyatnikov, G.
1996-01-01
This paper represents our data of comparative analysis of efficacy of different countermeasures in decontamination of soils in Ukraine in total and in case study Milyachi. On this base it was created of optimal algorithm of strategy of decontamination of soils which is based on method of usage turf harvester for unploughed soils and method of phytodesactivation for ploughed soils of Ukraine after Chernobyl accident
Chemical decontamination process and device therefor
International Nuclear Information System (INIS)
Takahashi, Ryota; Sakai, Hitoshi
1998-01-01
The present invention provides a process and a device for chemical decontamination, which can suppress corrosion of low corrosion resistant materials, keep decontamination properties substantially as same as before and further, reduce the volume of secondary wastes. In a step of reductively melting oxide membranes on an objective material to be decontaminated, a mixture of oxalic acid and a salt thereof is used as a reducing agent, and the reductive melting is conducted while suppressing hydrogen ion concentration of an aqueous liquid system. In order to enhance the reducibility of the oxalic acid ions, it is desirable to add a cyclic hetero compound thereto. The device of the present invention comprises, a decontamination loop including a member to be decontaminated, a heater and a pH meter, a medical injection pump for injecting a reducing agent to the decontamination loop, a metal ion recovering loop including an ion exchange resin tower, a reducing agent decomposing loop including an electrolytic vessel and/or a UV ray irradiation cell, a circulation pump for circulating the decontamination liquid to each of the loops and a plurality of opening/closing valves for switching the loop in which the decontamination liquid is circulated. (T.M.)
Experience with dilute chemical decontamination in Indian Pressurized Heavy Water Reactors
International Nuclear Information System (INIS)
Velmurugan, S.; Rufus, A.L.; Sathyaseelan, V.S.; Subramanian, Veena; Mittal, V.K.; Narasimhan, S.V.
2010-01-01
Dilute Chemical Decontamination (DCD) process has been used in several full system and components of nuclear coolant systems to effectively remove the radioactive contaminants that causes radiation field and consequent MANREM problem. The DCD process uses chemicals in very low concentrations (millimolar) and dissolves the oxide film along with the activity incorporated in the oxide film. In DCD process operated under the regenerative mode, the chemical formulation spent in the process of oxide dissolution is replenished by passing through cation exchange columns. Finally, after achieving sufficient decontamination of the system/component, the added decontamination chemicals along with the activities and metal ions released during the process are removed by mixed bed ion exchange columns and the system is restored to normal operating condition in few days time. In PHWRs, the regenerative DCD process is applied for full primary coolant system decontamination. The chemicals are added directly to the heavy water coolant with the fuel in the core. In Indian PHWRs (MAPS-1 and 2, RAPS-1 and 2, NAPS-1 and 2 and KAPS-1), the process has been applied eleven times. A chemical formulation based on NTA, Citric acid and Ascorbic acid has been applied seven times with good results. Decontamination factors in the range 2-30 have been obtained in different components with good MANREM savings in the subsequent maintenance works. Efforts are on to modify the process to take care of the challenges posed by antimony isotope. An inhibitor (Rodine-92B) based process was successfully tested in NAPS-2 for removing antimony isotopes ( 122 Sb and 124 Sb). Further refining of the antimony removal process is being worked out. Similarly, the process is being modified to effectively remove the hotspot causing stellite particles in the moderator system of PHWRs. A permanganate based process has been developed and tested in several adjustor rod drive mechanisms in KAPS and NAPS. The experience of
International Nuclear Information System (INIS)
Moehrle, G.
1975-01-01
A general survey of skin decontamination is given. The success of every decontamination treatments depends mainly on the speed, but also on the care, with which the action is taken. The best way to remove the skin contaminants is thorough washing under lukewarm running water with mild soap and a soft brush. This washing is to be repeated several times for a period of several minutes. If results are not satisfactory, light duty detergents and wetting agents available commercially may also be used. Some solutions which have proved useful are mentioned. The decontamination solutions are best used in the order given. When one has no satisfactory decontamination effect, the next one is to be used. If necessary, these agents must be used several times in the stated order as long as this does not involve too much strain for the skin. All the decontamination measures mentioned refer, of course, to intact healthy skin. After decontamination has been completed, the skin should be treated with a protective cream
Water vapor movement in freezing aggregate base materials.
2014-06-01
The objectives of this research were to 1) measure the extent to which water vapor movement results in : water accumulation in freezing base materials; 2) evaluate the effect of soil stabilization on water vapor movement : in freezing base materials;...
International Nuclear Information System (INIS)
Munson, L.F.; Card, C.J.; Divine, J.R.
1983-02-01
Previously used chemical decontamination processes and potentially useful new decontamination processes were examined for the usefulness following a reactor accident. Both generic fuel damage accidents and the accident at TMI-2 were considered. A total of fourteen processes were evaluated. Process evaluation included data in the following categories: technical description of the process, recorded past usage, effectiveness, process limitation, safety consideration, and waste management. These data were evaluated, and cost considerations were presented along with a description of the applicability of the process to TMI-2 and development and demonstration needs. Specific recommendations regarding a primary-system decontamination development program to support TMI-2 recovery were also presented
International Nuclear Information System (INIS)
Montford, B.
1975-01-01
Development of special techniques has permitted the use of mild decontamination processes for the CANDU type reactor primary coolant circuit, overcoming many of the problems associated with conventional decontamination processes, which use strong, acidic reagents. (Author)
International Nuclear Information System (INIS)
Szabo-Nagy, Andrea; Varga, Kalman; Deak-Horvath, Emese; Nemeth, Zoltan; Horvath, David; Schunk, Janos; Patek, Gabor
2012-09-01
Decontamination technologies are mainly developed to reduce the collective dose of the maintenance personnel at NPPs. The highest efficiency (i.e., the highest DF values) available without detrimental modification of the treated surface of structural material is the most important goal in the course of the application of a decontamination technology. A so-called 'soft' chemical decontamination technology has been developed - supported by the Paks Nuclear Power Plant - at the Institute of Radiochemistry and Radioecology of the University of Pannonia. The novel base technology can be effectively applied for the decontamination of the heat exchanger tubes of steam generators. In addition, by optimizing the main technological parameters (temperature, concentration of the liquid chemicals, flow rates, contact time, etc.) it can be utilized for specific applications such as decontamination of some dismountable devices and separable equipment or the total decontamination prior to plant dismantling (decommissioning) in the future. The aim of this work is to compare the efficiency, corrosion and surface chemical effects of some improved versions of the novel base-technology elaborated for decontamination of austenitic stainless steel surfaces. The experiments have been performed at laboratory conditions in decontamination model systems. The applied methods: γ-spectrometry, ICP-OES, voltammetry and SEM-EDX. The experimental results revealed that the efficiency of the base-technology mainly depends on the surface features of the stainless steel samples such as the chemical composition and thickness of the oxide layer, the nature (quantity, morphology and chemical composition) of the crystalline deposits. It has been documented that the improved version of the base-technology are suitable for the decontamination of both steel surfaces covered by chemically resistant large Cr-content crystals and that having compact oxide-layers (up to a thickness of 10
Assessment of microwave-based clinical waste decontamination unit.
Hoffman, P N; Hanley, M J
1994-12-01
A clinical waste decontamination unit that used microwave-generated heat was assessed for operator safety and efficacy. Tests with loads artificially contaminated with aerosol-forming particles showed that no particles were detected outside the machine provided the seals and covers were correctly seated. Thermometric measurement of a self-generated steam decontamination cycle was used to determine the parameters needed to ensure heat disinfection of the waste reception hopper, prior to entry for maintenance or repair. Bacterial and thermometric test pieces were passed through the machine within a full load of clinical waste. These test pieces, designed to represent a worst case situation, were enclosed in aluminium foil to shield them from direct microwave energy. None of the 100 bacterial test pieces yielded growth on culture and all 100 thermal test pieces achieved temperatures in excess of 99 degrees C during their passage through the decontamination unit. It was concluded that this method may be used to render safe the bulk of of ward-generated clinical waste.
Results of tritium tests performed on Sandia Laboratories decontamination system
International Nuclear Information System (INIS)
Gildea, P.D.; Wall, W.R.; Gede, V.P.
1978-05-01
The Tritium Research Laboratory (TRL), a facility for performing experiments using gram amounts of tritium, became operational on October 1, 1977. As secondary containment, the TRL employs sealed glove boxes connected on demand to two central decontamination systems, the Gas Purification System and the Vacuum Effluent Recovery System. Performance tests on these systems show the tritium removal systems can achieve concentration reduction factors (ratio of inlet to exhaust concentrations) much in excess of 1000 per pass at inlet concentrations of 1 part per million or less for both tritium and tritiated methane
Health physics and industrial hygiene aspects of decontamination as a precursor to decontamination
International Nuclear Information System (INIS)
Card, C.J.; Hoenes, G.R.; Munson, L.F.; Halseth, G.A.
1982-06-01
The Pacific Northwest Laboratory is conducting a comprehensive study of the impacts, benefits and effects of decontamination as a precursor to decommissioning for the US Nuclear Regulatory Commission. The program deals primarily with chemical cleaning of light-water reactor (LWR) systems that will not be returned to operation. A major section of this study defines the health physics and industrial hygiene and safety concerns during decontamination operations. The primary health physics concerns include providing adequate protection for workers from radiation sources which are transported by the decontamination processes, estimating and limiting radioactive effluents to the environment and maintaining operations in accordance with the ALARA philosophy. Locating and identifying the areas of contamination and measuring the radiation exposure rates throughout the reactor primary system are fundamental to implementing these health physics goals. The principal industrial hygiene and safety concerns stem from the fact that a nuclear power plant is being converted for a time to a chemical plant which will contain large volumes of chemical solutions
Gravett, M R; Hopkins, F B; Self, A J; Webb, A J; Timperley, C M; Riches, J R
2014-08-01
In the event of alleged use of organophosphorus nerve agents, all kinds of environmental samples can be received for analysis. These might include decontaminated and charred matter collected from the site of a suspected chemical attack. In other scenarios, such matter might be sampled to confirm the site of a chemical weapon test or clandestine laboratory decontaminated and burned to prevent discovery. To provide an analytical capability for these contingencies, we present a preliminary investigation of the effect of accelerant-based fire and liquid decontamination on soil contaminated with the nerve agent O-ethyl S-2-diisopropylaminoethyl methylphosphonothiolate (VX). The objectives were (a) to determine if VX or its degradation products were detectable in soil after an accelerant-based fire promoted by aviation fuel, including following decontamination with Decontamination Solution 2 (DS2) or aqueous sodium hypochlorite, (b) to develop analytical methods to support forensic analysis of accelerant-soaked, decontaminated and charred soil and (c) to inform the design of future experiments of this type to improve analytical fidelity. Our results show for the first time that modern analytical techniques can be used to identify residual VX and its degradation products in contaminated soil after an accelerant-based fire and after chemical decontamination and then fire. Comparison of the gas chromatography-mass spectrometry (GC-MS) profiles of VX and its impurities/degradation products from contaminated burnt soil, and burnt soil spiked with VX, indicated that the fire resulted in the production of diethyl methylphosphonate and O,S-diethyl methylphosphonothiolate (by an unknown mechanism). Other products identified were indicative of chemical decontamination, and some of these provided evidence of the decontaminant used, for example, ethyl 2-methoxyethyl methylphosphonate and bis(2-methoxyethyl) methylphosphonate following decontamination with DS2. Sample preparation
Decontamination of the Douglas Point reactor, May 1983
International Nuclear Information System (INIS)
Lesurf, J.E.; Stepaniak, R.; Broad, L.G.; Barber, W.G.
1983-01-01
The Douglas Point reactor primary heat transport system including the fuel, was successfully decontaminated by the CAN-DECON process in 1975. A second decontamination, also using the CAN-DECON process, was successfully performed in May 1983. This paper outlines the need for the decontamination, the process used, the results obtained, and the benefits to the station maintenance and operation
The feasibility study of hot cell decontamination by the PFC spray method
International Nuclear Information System (INIS)
Hui-Jun Won; Chong-Hun Jung; Jei-Kwon Moon
2008-01-01
The characteristics of per-fluorocarbon compounds (PFC) are colorless, non-toxic, easily vaporized and nonflammable. Also, some of them are liquids of a high density, low surface tension, low latent heat and low specific heat. These particular chemical and physical properties of fluoro-organic compounds permit their use in very different fields such as electronics, medicine, tribology, nuclear and material science. The Sonatol process was developed under a contract with the DOE. The Sonatol process uses an ultrasonic agitation in a PFC solution that contains a fluorinated surfactant to remove radioactive particles from surfaces. Filtering the suspended particles allows the solutions to be reused indefinitely. They applied the Sonatol process to the decontamination of a heterogeneous legacy Pu-238 waste that exhibited an excessive hydrogen gas generation, which prevents a transportation of such a waste to a Waste Isolation Pilot Plant. Korea Atomic Energy Research Institute (KAERI) is developing dry decontamination technologies applicable to a decontamination of a highly radioactive area loosely contaminated with radioactive particles. This contamination has occurred as a result of an examination of a post-irradiated material or the development of the DUPIC process. The dry decontamination technologies developed are the carbon dioxide pellet spray method and the PFC spray method. As a part of the project, PFC ultrasonic decontamination technology was developed in 2004. The PFC spray decontamination method which is based on the test results of the PFC ultrasonic method has been under development since 2005. The developed PFC spray decontamination equipment consists of four modules (spray, collection, filtration and distillation). Vacuum cup of the collection module gathers the contaminated PFC solution, then the solution is moved to the filtration module and it is recycled. After a multiple recycling of the spent PFC solution, it is purified in the distillation
Electrolytic decontamination of the 3013 inner can
International Nuclear Information System (INIS)
Wedman, D.E.; Nelson, T.O.; Rivera, Y.; Weisbrod, K.; Martinez, H.E.; Limback, S.
1998-01-01
Disposition of plutonium recovered from nuclear weapons or production residues must be stored in a manner that ensures safety. The criteria that has been established to assure the safety of stored materials for a minimum of 50 years is DOE-STD-3013. Los Alamos National Laboratory (LANL) has designed a containment package in accordance with the DOE standard. The package consists of an optional convenience (food pack) can, a welded type 304L stainless steel inner (primary) can, and a welded type 304L stainless steel outer (secondary) can. With or without the food pack can, the material is placed inside the primary can and welded shut under a helium atmosphere. This activity takes place totally within the confinement of the glove box line. Following the welding process, the can is checked for leaks and then sent down the line for decontamination. Once decontaminated, the sealed primary can may be removed from the glove box line. Welding of the secondary container takes place outside the glove box line. The highly automated decontamination process that has been developed to support the packaging of Special Nuclear Materials is based on an electrolytic process similar to the wide spread industrial technique of electropolishing. The can is placed within a specially designed stainless steel fixture built within a partition of a glove box. This fixture is then filled with a flowing electrolyte solution. A low DC electric current is made to flow between the can, acting as the anode, and the fixture, acting as the cathode. Following the decontamination, the system provides a flow of rinse water through the fixture to rinse the can of remaining salt residues. The system then carried out a drying cycle. Finally, the fixture is opened from the opposite side of the partition and the can surface monitored directly and through surface smears to assure that decontamination is adequate
Sentis, Marc L.; Delaporte, Philippe C.; Marine, Wladimir; Uteza, Olivier P.
2000-04-01
The application of excimer laser ablation process to the decontamination of radioactive surfaces is discussed. This technology is very attractive because it allows to efficiently remove the contaminated particles without secondary waste production. To demonstrate the capability of such technology to efficiently decontaminate large area, we studied and developed a prototype which include a XeCl laser, an optical fiber delivery system and an ablated particles collection cell. The main physical processes taking place during UV laser ablation will be explained. The influence of laser wavelength, pulse duration and absorption coefficient of material will be discussed. Special studies have been performed to understand the processes which limit the transmission of high average power excimer laser through optical fiber, and to determine the laser conditions to optimize the value of this transmission. An in-situ spectroscopic analysis of laser ablation plasma allows the real time control of the decontamination. The results obtained for painting or metallic oxides removal from stainless steel surfaces will be presented.
International Nuclear Information System (INIS)
Dev, H.
1994-01-01
Over the last nine years IIT Research Institute (IITRI) has been developing and testing the in situ heating and soil decontamination process for the remediation of soils containing hazardous organic contaminants. In this process the soil is heated in situ using electrical energy. The contaminants are removed from the soil due to enhanced vaporization, steam distillation and stripping. The vaporized contaminants, water vapor and air are recovered from the heated zone by means of a vacuum manifold system which collects gases from below surface as well as from the soil surface. A vapor barrier is used to prevent fugitive emissions of the contaminants and to control air infiltration to minimize dilution of the contaminant gases and vapors. The recovered gases and vapors are conveyed to an on site vapor treatment system for the clean up of the vent gases. Electrical energy is applied to the soil by forming an array of electrodes in the soil which are electrically interconnected and supplied with power. The electrodes are placed in drilled bore holes which are made through the contaminated zone. There are two versions of the in situ heating and soil treatment process: the f irst version is called the In Situ Radio Frequency (RF) Soil Decontamination Process and the second version is called the In Situ Electromagnetic (EM) Soil Decontamination Process. The first version, the RF Process is capable of heating the soil in a temperature range of 100 degrees to 400 degrees C. The soil temperature in the second version, the EM Process, is limited to the boiling point of water under native conditions. Thus the soil will be heated to a temperature of about 85 degrees to 95 degrees C. In this project IITRI will demonstrate the EM Process for in situ soil decontamination at K-25 Site due to the fact that most of the contaminants of concern are volatile organics which can be removed by heating the soil to a temperature range of 85 degrees to 95 degrees C
Energy Technology Data Exchange (ETDEWEB)
Dev, H.
1994-08-16
Over the last nine years IIT Research Institute (IITRI) has been developing and testing the in situ heating and soil decontamination process for the remediation of soils containing hazardous organic contaminants. In this process the soil is heated in situ using electrical energy. The contaminants are removed from the soil due to enhanced vaporization, steam distillation and stripping. The vaporized contaminants, water vapor and air are recovered from the heated zone by means of a vacuum manifold system which collects gases from below surface as well as from the soil surface. A vapor barrier is used to prevent fugitive emissions of the contaminants and to control air infiltration to minimize dilution of the contaminant gases and vapors. The recovered gases and vapors are conveyed to an on site vapor treatment system for the clean up of the vent gases. Electrical energy is applied to the soil by forming an array of electrodes in the soil which are electrically interconnected and supplied with power. The electrodes are placed in drilled bore holes which are made through the contaminated zone. There are two versions of the in situ heating and soil treatment process: the f irst version is called the In Situ Radio Frequency (RF) Soil Decontamination Process and the second version is called the In Situ Electromagnetic (EM) Soil Decontamination Process. The first version, the RF Process is capable of heating the soil in a temperature range of 100{degrees} to 400{degrees}C. The soil temperature in the second version, the EM Process, is limited to the boiling point of water under native conditions. Thus the soil will be heated to a temperature of about 85{degrees} to 95{degrees}C. In this project IITRI will demonstrate the EM Process for in situ soil decontamination at K-25 Site due to the fact that most of the contaminants of concern are volatile organics which can be removed by heating the soil to a temperature range of 85{degrees} to 95{degrees}C.
Modelling Mass Casualty Decontamination Systems Informed by Field Exercise Data
Directory of Open Access Journals (Sweden)
Richard Amlôt
2012-10-01
Full Text Available In the event of a large-scale chemical release in the UK decontamination of ambulant casualties would be undertaken by the Fire and Rescue Service (FRS. The aim of this study was to track the movement of volunteer casualties at two mass decontamination field exercises using passive Radio Frequency Identification tags and detection mats that were placed at pre-defined locations. The exercise data were then used to inform a computer model of the FRS component of the mass decontamination process. Having removed all clothing and having showered, the re-dressing (termed re-robing of casualties was found to be a bottleneck in the mass decontamination process during both exercises. Computer simulations showed that increasing the capacity of each lane of the re-robe section to accommodate 10 rather than five casualties would be optimal in general, but that a capacity of 15 might be required to accommodate vulnerable individuals. If the duration of the shower was decreased from three minutes to one minute then a per lane re-robe capacity of 20 might be necessary to maximise the throughput of casualties. In conclusion, one practical enhancement to the FRS response may be to provide at least one additional re-robe section per mass decontamination unit.
A survey of decontamination processes applicable to DOE nuclear facilities
International Nuclear Information System (INIS)
Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.
1997-05-01
The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs
A survey of decontamination processes applicable to DOE nuclear facilities
Energy Technology Data Exchange (ETDEWEB)
Chen, L.; Chamberlain, D.B.; Conner, C.; Vandegrift, G.F.
1997-05-01
The objective of this survey was to select an appropriate technology for in situ decontamination of equipment interiors as part of the decommissioning of U.S. Department of Energy nuclear facilities. This selection depends on knowledge of existing chemical decontamination methods. This report provides an up-to-date review of chemical decontamination methods. According to available information, aqueous systems are probably the most universally used method for decontaminating and cleaning metal surfaces. We have subdivided the technologies, on the basis of the types of chemical solvents, into acid, alkaline permanganate, highly oxidizing, peroxide, and miscellaneous systems. Two miscellaneous chemical decontamination methods (electrochemical processes and foam and gel systems) are also described. A concise technical description of various processes is given, and the report also outlines technical considerations in the choice of technologies, including decontamination effectiveness, waste handing, fields of application, and the advantages and limitations in application. On the basis of this survey, six processes were identified for further evaluation. 144 refs., 2 tabs.
Decontamination of lead by fusion (1962); Decontamination du plomb par fusion (1962)
Energy Technology Data Exchange (ETDEWEB)
Boutot, P; Giachetto, L; Capitaine, A [Commissariat a l' Energie Atomique, Centre de Production de Plutonium, Marcoule (France). Centre d' Etudes Nucleaires
1962-07-01
Various attempts to decontaminate using mechanical and chemical methods having given questionable results, a fusion method has been developed. The apparatus consists of a propane-heated oven fitted with a steel crucible of 1 400 kg capacity, with two ventilation systems, and with a vacuum gauge for preventing the diffusion of toxic gases. There are three operational controls : 1. On the samples taken before during and after the operation, 2. On the plugs taken from the ingots, 3. On the ingot itself. The continuous sanitary control is done by a radioactive aerosol recorder and by periodic sampling. This decontamination process will be improved, especially as far as the productivity and the safety precautions are concerned. (authors) [French] Divers essais de decontamination par voies mecaniques et chimiques ayant donne des resultats discutables, un procede par fusion a ete mis au point. L'appareil se compose d'un four, chauffe au propane, muni d'un creuset en acier d'une capacite de 1 400 kg, de deux systemes de ventilation et d'un deprimometre afin d'eviter la diffusion de vapeurs nocives. Trois controles d'activite sont effectues: 1. sur des echantillons preleves avant, pendant et apres l'operation, 2. sur des carottages realises sur les lingots, 3. sur le lingot lui-meme. Le controle sanitaire permanent est assure par un enregistreur d'aerosols radioactifs et par des prelevements periodiques. Ce procede de decontamination doit encore etre ameliore, principalement en ce qui concerne la productivite et la securite. (auteurs)
W-12 valve pit decontamination demonstration
International Nuclear Information System (INIS)
Benson, C.E.; Parfitt, J.E.; Patton, B.D.
1995-12-01
Waste tank W-12 is a tank in the ORNL Low-Level Liquid Waste (LLLW) system that collected waste from Building 3525. Because of a leaking flange in the discharge line from W-12 to the evaporator service tank (W-22) and continual inleakage into the tank from an unknown source, W-12 was removed from service to comply with the Federal Facilities Agreement requirement. The initial response was to decontaminate the valve pit between tank W-12 and the evaporator service tank (W-22) to determine if personnel could enter the pit to attempt repair of the leaking flange. Preventing the spread of radioactive contamination from the pit to the environment and to other waste systems was of concern during the decontamination. The drain in the pit goes to the process waste system; therefore, if high-level liquid waste were generated during decontamination activities, it would have to be removed from the pit by means other than the available liquid waste connection. Remote decontamination of W-12 was conducted using the General Mills manipulator bridge and telescoping trolley and REMOTEC RM-10 manipulator. The initial objective of repairing the leaking flange was not conducted because of the repair uncertainty and the unknown tank inleakage. Rather, new piping was installed to empty the W-12 tank that would bypass the valve pit and eliminate the need to repair the flange. The radiological surveys indicated that a substantial decontamination factor was achieved
Decontamination of nuclear facilities
International Nuclear Information System (INIS)
1982-01-01
Thirty-seven papers were presented at this conference in five sessions. Topics covered include regulation, control and consequences of decontamination; decontamination of components and facilities; chemical and non-chemical methods of decontamination; and TMI decontamination experience
Chemical decontamination solutions: Effects on PWR equipment
International Nuclear Information System (INIS)
Pezze, C.M.; Colvin, E.R.; Aspden, R.G.
1992-01-01
A critical objective for the nuclear industry is the reduction of personnel exposure to radiation. Reductions have been achieved through industry's radiation management programs including training and radiation awareness concepts. Increased plant maintenance and higher radiation fields at many sites continue to raise concerns. To alleviate the radiation exposure problem, the sources of radiation which contribute to personnel exposure must be removed from the plant. A feasible was of significantly reducing these sources from a Pressurized Water Reactor (PWR) is to chemically decontaminate the entire reactor coolant system (RCS). A program was conducted to determine the technical acceptability of using certain dilute chemical solvent processes for full RCS chemical decontamination. The two processes evaluated were CAN-DEREM and LOMI. The purpose of the program was to define and complete a systematic evaluation of the major issues that need to be addressed for the successful decontamination of the entire RCS and affected portions of the auxiliary systems of a four-loop PWR system. A test program was designed to evaluate the corrosion effects of the two decontamination processes under expected plant conditions. Materials and sample configurations dictated by generic PWR components were evaluated. The testing also included many standard corrosion coupons. The test data were then used to assess the impact of chemical decontamination on the physical condition and operability of the components, equipment and mechanical systems that make up the RCS. An overview of the test program, sample configurations, data and engineering evaluations is presented. The data demonstrate that through detailed engineering evaluations of corrosion data and equipment function, the impact of full RCS chemical decontamination on plant equipment is established
Decontamination impacts on solidification
International Nuclear Information System (INIS)
Piciulo, P.L.; Davis, M.S.
1985-01-01
The increased occupational exposure resulting from the accumulation of activated corrosion products in the primary system of LWRs has led to the development of chemical methods to remove the contamination. In the past, the problem of enhanced migration of radionuclides away from trenches used to dispose of low-level radioactive waste, has been linked to the presence, at the disposal unit, of chelating or complexing agents such as those used in decontamination processes. These agents have further been found to reduce the normal sorptive capacity of soils for radionuclides. The degree to which these agents inhibit the normal sorptive processes is dependent on the type of complexing agent, the radionuclide of concern, the soil properties and whether the nuclide is present as a complex or is already sorbed to the soil. Since the quantity of reagent employed in a full system decontamination is large (200 to 25,000 kg), the potential for enhanced migration of radionuclides from a site used to dispose of the decontamination wastes should be addressed and guidelines established for the safe disposal of these wastes
Decontamination method for radiation contaminated metal
International Nuclear Information System (INIS)
Enda, Masami; Hosaka, Katsumi; Sakai, Hitoshi.
1997-01-01
An organic acid solution is used as a decontamination liquid, and base materials of radiation contaminated metals are dissolved in the solution. The concentration of the organic acid is measured, and the organic acid is supplied by an amount corresponding to the lowering of the concentration. The decontamination liquid wastes generated during the decontamination step are decomposed, and metals leached in the organic acid solution are separated. With such procedures, contamination intruded into the inside of the mother materials of the metals can be removed, and radioactivity of the contaminated metals such as stainless steels and carbon steels can be eliminated, or the radiation level thereof can be reduced. In addition, the amount of secondary wastes generated along with the decontamination can be suppressed. (T.M.)
International Nuclear Information System (INIS)
Silva, S. da; Teixeira, M.V.
1986-06-01
The general methods of surface decontamination used in laboratory and others nuclear installations areas, as well as the procedures for handling radioactive materials and surfaces of work are presented. Some methods for decontamination of body external parts are mentioned. The medical supervision and assistance are required for internal or external contamination involving or not lesion in persons. From this medical radiation protection decontamination procedures are determined. (M.C.K.) [pt
Reactive decontamination formulation
Giletto, Anthony [College Station, TX; White, William [College Station, TX; Cisar, Alan J [Cypress, TX; Hitchens, G Duncan [Bryan, TX; Fyffe, James [Bryan, TX
2003-05-27
The present invention provides a universal decontamination formulation and method for detoxifying chemical warfare agents (CWA's) and biological warfare agents (BWA's) without producing any toxic by-products, as well as, decontaminating surfaces that have come into contact with these agents. The formulation includes a sorbent material or gel, a peroxide source, a peroxide activator, and a compound containing a mixture of KHSO.sub.5, KHSO.sub.4 and K.sub.2 SO.sub.4. The formulation is self-decontaminating and once dried can easily be wiped from the surface being decontaminated. A method for decontaminating a surface exposed to chemical or biological agents is also disclosed.
Energy Technology Data Exchange (ETDEWEB)
Lee, Jae bong; Kim, Sung Il; Jung, Jaehoon; Ha, Kwang Soon; Kim, Hwan Yeol [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2016-10-15
Fission products would be released from molten corium pools which are relocated into the lower plenum of reactor pressure vessel, on the concrete pit and in the core catcher. In addition, steam, hydrogen and noncondensable gases such as CO and CO2 are generated during the core damage progression due to loss of coolant and the molten core-concrete interaction. Consequently, the pressure inside the containment could be increased continuously. Filtered containment venting is one action to prevent an uncontrolled release of radioactive fission products caused by an overpressure failure of the containment. After the Fukushima-Daiichi accident which was demonstrated the containment failure, many countries to consider the implementation of filtered containment venting system(FCVS) on nuclear power plant where these are not currently applied. In general evaluation for FCVS is conducted to determine decontamination factor on several conditions (aerosol diameter, submergence depth, water temperature, gas flow, steam flow rate, pressure, operating time,...). It is essential to quantify the mass concentration before and after FCVS for decontamination factor. This paper presents the development of the evaluation facility for filtered containment venting system at KAERI and an experimental investigation for aerosol removal performance. Decontamination factor for the FCVS is determined by filter measurement. The result of the aerosol size distribution measurement shows the aerosol removal performance by an aerosol size.
Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W
2017-11-01
Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. 'Static-open' VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, 'active-closed' VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains.
Deactivation, Decontamination and Decommissioning Project Summaries
Energy Technology Data Exchange (ETDEWEB)
Peterson, David Shane; Webber, Frank Laverne
2001-07-01
This report is a compilation of summary descriptions of Deactivation, Decontamination and Decommissioning, and Surveillance and Maintenance projects planned for inactive facilities and sites at the INEEL from FY-2002 through FY-2010. Deactivations of contaminated facilities will produce safe and stable facilities requiring minimal surveillance and maintenance pending further decontamination and decommissioning. Decontamination and decommissioning actions remove contaminated facilities, thus eliminating long-term surveillance and maintenance. The projects are prioritized based on risk to DOE-ID, the public, and the environment, and the reduction of DOE-ID mortgage costs and liability at the INEEL.
Decontamination and materials corrosion concerns in the BWR
International Nuclear Information System (INIS)
Gordon, B.M.; Gordon, G.M.
1988-01-01
The qualification of chemical decontamination processes to decontaminate complete systems or individual components in essential if effective inspection, maintenance, repair or replacement of plant components is to be achieved with minimum exposure of workers to ionizing radiation. However, it is critical that the benefits of decontamination processes are not overshadowed by deleterious materials/ corrosion side effects during the application of the process or during subsequent operation. This paper discusses such potential corrosion/materials problems in the BWR and presents relevant available corrosion data for the various commercial decontamination processes. (author)
Decontaminating reagents for radioactive systems
International Nuclear Information System (INIS)
Seddon, W.A.
1982-01-01
A decontaminating reagent composition has been developed comprising EDTA, citric acid, oxalic acid, and formic acid. Formic acid inhibits the decomposition of both EDTA and citric acid, and yields oxalic acid as a result of its own radiolysis. The invention includes the improvement of initially incorporating formic acid in the mixture and maintaining the presence of formic acid by at least one further addition
Experiences with decontaminating tritium-handling apparatus
International Nuclear Information System (INIS)
Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.
1991-07-01
Tritium-handling apparatus has been decontaminated as part of the shutdown of the LLNL Tritium Facility. Two stainless-steel gloveboxes that had been used to process lithium deuteride-tritide (LiDT) salt were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. Further surface decontamination was performed by scrubbing the interior with paper towels and ethyl alcohol or Swish trademark. The surface contamination, as shown by swipe surveys, was reduced from 4x10 4 --10 6 disintegrations per minute (dpm)/cm 2 to 2x10 2 --4x10 4 dpm/cm 2 . Details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given
Chemical decontamination of non-dismounted equipment of nuclear power stations
International Nuclear Information System (INIS)
Oertel, K.; Dietrich, P.; Hildebrandt, N.
1979-01-01
Reasons for performing system chemical decontaminations are considered, some cases of practical application to water cooled power reactors are discussed, radical and soft decontamination techniques are compared with each other, and evaluation criteria for decontaminations are studied. (author)
Decontaminating lead bricks and shielding
International Nuclear Information System (INIS)
Lussiez, G.W.
1993-01-01
Lead used for shielding is often surface contaminated with radioisotopes and is therefore a RCRA D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Laboratory decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 50 tons and likely to grow substantially because of planned decommissioning operations. This lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for decontaminating lead is removing the thin superficial layer of contamination with an abrasive medium trader pressure. For lead, a mixture of alumina with water and air at about 40 psig rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a sealed-off area. The slurry of abrasive and particles of lead falls through a floor grating and is collected in a sump. A pump sends the slurry mixture back to the spray gun, creating a continuous process. The process generates small volumes of contaminated lead slurry that can be solidified and, because it passes the TCLP, is not a mixed waste. The decontaminated lead can be released for recycling
Energy Technology Data Exchange (ETDEWEB)
Lin, Tzu-Shun [Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, 701 Tainan, Taiwan, ROC (China); Lee, Ching-Ting, E-mail: ctlee@ee.ncku.edu.tw [Institute of Nanotechnology and Microsystems Engineering, National Cheng Kung University, 701 Tainan, Taiwan, ROC (China); Institute of Microelectronics, Department of Electrical Engineering, Advanced Optoelectronic Technology Center, National Cheng Kung University, 701 Tainan, Taiwan, ROC (China)
2015-11-01
Highlights: • The vapor cooling condensation system was designed and used to deposit homostructured ZnO-based metal-oxide-semiconductor field-effect transistors. • The resulting homostructured ZnO-based MOSFETs operated at a reverse voltage of −6 V had a very low gate leakage current of 24 nA. • The associated I{sub DSS} and the g{sub m(max)} were 5.64 mA/mm and 1.31 mS/mm, respectively. - Abstract: The vapor cooling condensation system was designed and used to deposit homostructured ZnO-based metal-oxide-semiconductor field-effect transistors (MOSFETs) on sapphire substrates. Owing to the high quality of the deposited, various ZnO films and interfaces, the resulting MOSFETs manifested attractive characteristics, such as the low gate leakage current of 24 nA, the low average interface state density of 2.92 × 10{sup 11} cm{sup −2} eV{sup −1}, and the complete pinch-off performance. The saturation drain–source current, the maximum transconductance, and the gate voltage swing of the resulting homostructured ZnO-based MOSFETs were 5.64 mA/mm, 1.31 mS/mm, and 3.2 V, respectively.
Decontaminating lead bricks and shielding
International Nuclear Information System (INIS)
Lussiez, G.W.
1993-01-01
Lead used for shielding is often surface contaminated with radionuclides and is therefore a Resource Conservation and Recovery Act (RCRA) D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Lab. decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 100 metric tons and likely to grow substantially because of planned decommissioning operations. This lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for decontaminating lead is removing the thin superficial layer of contamination with an abrasive medium under pressure. For lead, a mixture of alumina with water and air at about 280 kPa (40 psig) rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a sealed-off area. The slurry of abrasive and particles of lead falls through a floor grating and is collected in a pump. A pump sends the slurry mixture back to the spray gun, creating a continuous process
Systems and strippable coatings for decontaminating structures that include porous material
Fox, Robert V [Idaho Falls, ID; Avci, Recep [Bozeman, MT; Groenewold, Gary S [Idaho Falls, ID
2011-12-06
Methods of removing contaminant matter from porous materials include applying a polymer material to a contaminated surface, irradiating the contaminated surface to cause redistribution of contaminant matter, and removing at least a portion of the polymer material from the surface. Systems for decontaminating a contaminated structure comprising porous material include a radiation device configured to emit electromagnetic radiation toward a surface of a structure, and at least one spray device configured to apply a capture material onto the surface of the structure. Polymer materials that can be used in such methods and systems include polyphosphazine-based polymer materials having polyphosphazine backbone segments and side chain groups that include selected functional groups. The selected functional groups may include iminos, oximes, carboxylates, sulfonates, .beta.-diketones, phosphine sulfides, phosphates, phosphites, phosphonates, phosphinates, phosphine oxides, monothio phosphinic acids, and dithio phosphinic acids.
Optical acetone vapor sensors based on chiral nematic liquid crystals and reactive chiral dopants
Cachelin, P.; Green, J.P.; Peijs, T.; Heeney, M.; Bastiaansen, C.W.M.
2016-01-01
Accurate monitoring of exposure to organic vapors, such as acetone, is an important part of maintaining a safe working environment and adhering to long- and short-term exposure limits. Here, a novel acetone vapor detection system is described based on the use of a reactive chiral dopant in a nematic
A Simple Decontamination Approach Using Hydrogen ...
Journal article To evaluate the use of relatively low levels of hydrogen peroxide vapor (HPV) for the inactivation of Bacillus anthracis spores within an indoor environment. Methods and Results: Laboratory-scale decontamination tests were conducted using bacterial spores of both B. anthracis Ames and Bacillus atrophaeus inoculated onto several types of materials. Pilot-scale tests were also conducted using a larger chamber furnished as an indoor office. Commercial off-the-shelf (COTS) humidifiers filled with aqueous solutions of 3% or 8% hydrogen peroxide were used to generate the HPV inside the mock office. The spores were exposed to the HPV for periods ranging from 8 hours up to one week. Conclusions: Four to seven day exposures to low levels of HPV (average air concentrations of approximately 5-10 parts per million) were effective in inactivating B. anthracis spores on multiple materials. The HPV can be generated with COTS humidifiers and household H2O2 solutions. With the exception of one test/material, B. atrophaeus spores were equally or more resistant to HPV inactivation compared to those from B. anthracis Ames. Significance and Impact of Study: This simple and effective decontamination method is another option that could be widely applied in the event of a B. anthracis spore release.
New decontamination processes for liquid effluents and solid materials
International Nuclear Information System (INIS)
Faure, S.
2008-01-01
New decontamination processes are being studied in order to protect workers and to reduce strongly the quantity of secondary wastes produced. 2 decontamination processes for liquid nuclear wastes are under studies. First, the coprecipitation process whose improvement is based on a better control of the 2 coupled mechanisms involved in the process: the formation of adsorbent particles and the uptake of radionuclides. Secondly, the column process whose development focuses on new materials that can be used to absorb cesium in a reversible way. 3 new decontamination processes for solid materials are being developed. First, processes using drying gels are under investigation in order to treat materials like lead, aluminium, iron and stainless steel. Real decontamination of hot cells by drying gel process has been performed and a decontamination factor between 16 and 25 has been obtained on stainless steels. Secondly, new foam decontamination processes have been developed, they are based on the use of new foams stabilized by biodegradable non-ionic surfactants: alkyl-poly-glucosides and viscofiers or nano-particles. The aim is to increase the foam lifetime. Thirdly, new surfactants in solution decontamination processes have been studied, the aim is to decontaminate through degreasing by using acidic surfactants. The idea is to combine emulsification and wetting power. (A.C.)
Experiences with decontaminating tritium-handling apparatus
International Nuclear Information System (INIS)
Maienschein, J.L.; Garcia, F.; Garza, R.G.; Kanna, R.L.; Mayhugh, S.R.; Taylor, D.T.
1992-01-01
Tritium-handling apparatus has been decontaminated as part of the downsizing of the LLNL Tritium Facility. Two stainless-steel glove boxes that had been used to process lithium deuteride-tritide (LiDT) slat were decontaminated using the Portable Cleanup System so that they could be flushed with room air through the facility ventilation system. In this paper the details on the decontamination operation are provided. A series of metal (palladium and vanadium) hydride storage beds have been drained of tritium and flushed with deuterium, in order to remove as much tritium as possible. The bed draining and flushing procedure is described, and a calculational method is presented which allows estimation of the tritium remaining in a bed after it has been drained and flushed. Data on specific bed draining and flushing are given
Remote methods for decontamination and decommissioning operations
International Nuclear Information System (INIS)
DeVore, J.R.
1986-01-01
Three methods for the decontamination and decommissioning of nuclear facilities are described along with operational experience associated with each method. Each method described in some way reduces radiation exposure to the operating personnel involved. Electrochemical decontamination of process tanks is described using an in-situ method. Descriptions of two processes, electropolishing and cerium redox decontamination, are listed. A method of essentially smokeless cutting of process piping using a plasma-arc cutting torch is described. In one technique, piping is cut remotely from a distance using a specially modified torch holder. In another technique, cutting is done with master-slave manipulators inside a hot cell. Finally, a method for remote cutting and scarification of contaminated concrete is described. This system, which utilizes high-pressure water jets, is coupled to a cutting head or rotating scarification head. The system is suited for cutting contaminated concrete for removal or removing a thin layer in a controlled manner for decontamination. 4 refs., 6 figs
Remote methods for decontamination and decommissioning operations
International Nuclear Information System (INIS)
DeVore, J.R.
1986-01-01
Three methods for the decontamination and decommissioning of nuclear facilities are described along with operational experience associated with each method. Each method described in some way reduces radiation exposure to the operating personnel involved. Electrochemical decontamination of process tanks is described using an in-situ method. Descriptions of two processes, electropolishing and cerium redox decontamination, are listed. A method of essentially smokeless cutting of process piping using a plasma-arc cutting torch is described. In one technique, piping is cut remotely from a distance using a specially modified torch holder. In another technique, cutting is done with master-slave manipulators inside a hot cell. Finally, a method for remote cutting and scarification of contaminated concrete is described. This system, which utilizes high-pressure water jets, is coupled to a cutting head or rotating scarification head. The system is suited for cutting contaminated concrete for removal or removing a thin layer in a controlled manner for decontamination
Decontamination before dismantling a fast breeder reactor primary cooling system
International Nuclear Information System (INIS)
Costes, J.R.; Antoine, P.; Gauchon, J.P.
1997-01-01
The large-scale decontamination of FBR sodium loops is a novel task, as only a limited number of laboratory-scale results are available to date. The principal objective of this work is to develop a suitable decontamination procedure for application to the primary loops of the RAPSODIE fast breeder reactor as part of decommissioning to Stage 2. After disconnecting the piping from the main vessel, the pipes were treated by circulating chemical solutions and the vessels by spraying. The dose rate in the areas to be dismantled was divided by ten. A decontamination factor of about 300 was obtained, and should allow austenitic steel parts to be melted in special furnaces for unrestricted release. (author)
Aggressive chemical decontamination tests on small valves from the Garigliano BWR
International Nuclear Information System (INIS)
Bregani, F.
1990-01-01
In order to check the effectiveness of direct chemical decontamination on small and complex components, usually considered for storage without decontamination because of the small amount, some tests were performed on the DECO experimental loop. Four small stainless steel valves from the primary system of the Garigliano BWR were decontaminated using mainly aggressive chemicals such as HC1, HF, HNO 3 and their mixtures. On two valves, before the treatment with aggressive chemicals, a step with soft chemical (oxalic and citric acid mixture) was performed in order to see whether a softening action enhances the following aggressive decontamination. Moreover, in order to increase as much as possible the decontamination effectiveness, a decontamination process using ultrasounds jointly with aggressive chemicals was investigated. After an intensive laboratory testing programme, two smaller stainless steel valves from the primary system of the Garigliano BWR were decontaminated using ultrasounds in aggressive chemical solutions
Los Alamos DP West Plutonium Facility decontamination project
International Nuclear Information System (INIS)
Garde, R.; Cox, E.J.; Valentine, A.M.
1982-01-01
The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico, was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation
Decontamination systems information and research program. Quarterly report, January 1996--March 1996
International Nuclear Information System (INIS)
1996-04-01
West Virginia University (WVU) and the US Department of Energy, Morgantown Energy Technology Center (DOE/METC) entered into a Cooperative Agreement in August 1992 titled open-quotes Decontamination Systems Information and Research Programsclose quotes (DOE Instrument No.: DE-FC21-92MC29467). Requirements stipulated by the Agreement require WVU to submit quarterly Technical Progress reports. This report contains the efforts of the research projects comprising the Agreement for the 1st calendar quarter of 1996. For the period January 1 through December 31, 1996 twelve projects have been selected for funding, and the Kanawha Valley will continue under a no-cost extension. Three new projects have also been added to the program. This document describes these projects involving decontamination, decommissioning and remedial action issues and technologies
Development of peelable films for decontamination and their performances
International Nuclear Information System (INIS)
Yang Enbo; Xu Baolan; Zhao Xiuyan
1990-01-01
Two kinds of peelable films have been developed which can be coated on surface contaminated by radioactivity for decontamination purposes. Very high levels of radioactive decontamination, especially on smooth surface, are obtained after one application. 90-99% decontamination based on initial activity can be obtained for stainless steel, PVC floor and glass
Studies on residue-free decontaminants for chemical warfare agents.
Wagner, George W
2015-03-17
Residue-free decontaminants based on hydrogen peroxide, which decomposes to water and oxygen in the environment, are examined as decontaminants for chemical warfare agents (CWA). For the apparent special case of CWA on concrete, H2O2 alone, without any additives, effectively decontaminates S-2-(diisopropylamino)ethyl O-ethyl methylphosphonothioate (VX), pinacolyl methylphosphorofluoridate (GD), and bis(2-choroethyl) sulfide (HD) in a process thought to involve H2O2 activation by surface-bound carbonates/bicarbonates (known H2O2 activators for CWA decontamination). A plethora of products are formed during the H2O2 decontamination of HD on concrete, and these are characterized by comparison to synthesized authentic compounds. As a potential residue-free decontaminant for surfaces other than concrete (or those lacking adsorbed carbonate/bicarbonate) H2O2 activation for CWA decontamination is feasible using residue-free NH3 and CO2 as demonstrated by reaction studies for VX, GD, and HD in homogeneous solution. Although H2O2/NH3/CO2 ("HPAC") decontaminants are active for CWA decontamination in solution, they require testing on actual surfaces of interest to assess their true efficacy for surface decontamination.
Criteria and evaluation of three decontamination techniques
Energy Technology Data Exchange (ETDEWEB)
Tripp, J.L.
1994-01-01
Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO{sub 2} pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used.
Criteria and evaluation of three decontamination techniques
International Nuclear Information System (INIS)
Tripp, J.L.
1994-01-01
Past decontamination and solvent recovery activities at the Idaho Chemical Processing Plant (ICPP), which is part of the Idaho National Engineering Laboratory (INEL), have resulted in the accumulation of 1.5 million gallons of radioactively contaminated sodium-bearing liquid waste. Future decontamination activities at the ICPP could result in the production of 5 million gallons or more of sodium-bearing waste using the current decontamination techniques of chemical/water flushes and steam jet cleaning. This waste requires a large amount of cold chemical additive to process because the low melting temperatures of sodium and potassium salts cause agglomeration in the bed of the calciner vessel. Criteria have been established for evaluating methods and technologies available for decontaminating equipment and facilities. The criteria were weighted according to their relative importance using a Kepner-Tregoe Problem Solving process. These criteria were used to rank three decontamination techniques new to the ICPP: laser ablation, liquid abrasive blasting and CO 2 pellet blasting, against the standard decontamination techniques of sodium-based chemical cleaning and water/steam jets used
Sudarmaji, A.; Margiwiyatno, A.; Ediati, R.; Mustofa, A.
2018-05-01
The aroma/vapor of essential oils is complex compound which depends on the content of the gases and volatiles generated from essential oil. This paper describes a design of quick, simple, and low-cost static measurement system to acquire vapor profile of essential oil. The gases and volatiles are captured in a chamber by means of 9 MOS gas sensors which driven with advance temperature modulation technique. A PSoC CY8C28445-24PVXI based-interface unit is built to generate the modulation signal and acquire all sensor output into computer wirelessly via radio frequency serial communication using Digi International Inc., XBee (IEEE 802.15.4) through developed software under Visual.Net. The system was tested to measure 2 kinds of essential oil (Patchouli and Clove Oils) in 4 temperature modulations (without, 0.25 Hz, 1 Hz, and 4 Hz). A cycle measurement consists of reference and sample measurement sequentially which is set during 2 minutes in every 1 second respectively. It is found that the suitable modulation is 0,25Hz; 75%, and the results of Principle Component Analysis show that the system is able to distinguish clearly between Patchouli Oil and Clove Oil.
Water-Vapor Raman Lidar System Reaches Higher Altitude
Leblanc, Thierry; McDermid, I. Stewart
2010-01-01
A Raman lidar system for measuring the vertical distribution of water vapor in the atmosphere is located at the Table Mountain Facility (TMF) in California. Raman lidar systems for obtaining vertical water-vapor profiles in the troposphere have been in use for some time. The TMF system incorporates a number of improvements over prior such systems that enable extension of the altitude range of measurements through the tropopause into the lower stratosphere. One major obstacle to extension of the altitude range is the fact that the mixing ratio of water vapor in the tropopause and the lower stratosphere is so low that Raman lidar measurements in this region are limited by noise. Therefore, the design of the TMF system incorporates several features intended to maximize the signal-to-noise ratio. These features include (1) the use of 355-nm-wavelength laser pulses having an energy (0.9 J per pulse) that is high relative to the laser-pulse energy levels of prior such systems, (2) a telescope having a large aperture (91 cm in diameter) and a narrow field of view (angular width .0.6 mrad), and (3) narrow-bandpass (wavelength bandwidth 0.6 nm) filters for the water-vapor Raman spectral channels. In addition to the large-aperture telescope, three telescopes having apertures 7.5 cm in diameter are used to collect returns from low altitudes.
Ragland, Natalie H; Miedel, Emily L; Gomez, Jose M; Engelman, Robert W
2017-01-01
Vaporized hydrogen peroxide (VHP) is used to decontaminate clinical, biocontainment, and research animal rooms and equipment. To assist with its implementation in a murine facility, we developed a safe and effective method of VHP sterilization of IVC racks and air handling units (AHU). Safety of VHP decontamination was assessed by ensuring VHP levels dissipated to less than 1 ppm in the room prior to personnel reentry and inside the primary enclosure prior to the return of mice; this condition occurred at least 18 h after the VHP cycle. Efficacy of VHP sterilization was assessed by using chemical indicators, biologic indicators, and PCR testing for Staphylococcus xylosus, a commensal organism of murine skin and an opportunistic pathogen, which was present in 160 of 172 (93%) of specimens from occupied IVC racks and the interior surfaces of in-use AHU. Neither mechanized washing nor hand-sanitizing eradicated S. xylosus from equipment airway interiors, with 17% to 24% of specimens remaining PCR-positive for S. xylosus. ‘Static–open’ VHP exposure of sanitized equipment did not ensure its sterilization. In contrast, ‘active–closed’ VHP exposure, in which IVC racks were assembled, sealed, and connected to AHU set to the VHP cycle, increased the proportion of chemical indicators that detected sterilizing levels of VHP inside the assembled equipment, and significantly decreased PCR-detectable S. xylosus inside the equipment. Supplementing bulk steam sterilization of the primary enclosure with VHP sterilization of the secondary housing equipment during room change-outs may help to mitigate opportunistic agents that jeopardize studies involving immunodeficient strains. PMID:29256369
Low corrosive chemical decontamination method using pH control. 1. Basic system
International Nuclear Information System (INIS)
Nagase, Makoto; Ishida, Kazushige; Uetake, Naohito; Anazawa, Kazumi; Nakamura, Fumito; Yoshikawa, Hiroo; Tamagawa, Tadashi; Furukawa, Kiyoharu
2001-01-01
A new low corrosive decontamination method was developed which uses both oxalic acid and hydrazine as the reducing agent and potassium permanganate as the oxidizing agent. Less corrosion of structural materials during the decontamination is realized by pH control of the reducing agent. The pH of 2.5, attained by adding hydrazine to oxalic acid, was the optimum pH for maintaining a high decontamination effect and lowering the corrosion at the same time. As this reducing agent can be decomposed into carbon dioxide, nitrogen and water by using a catalyst column with hydrogen peroxide, the amount of secondary radioactive waste is small. These good features were demonstrated through actual plant decontamination tasks. (author)
Decontaminating lead bricks and shielding
International Nuclear Information System (INIS)
Lussiez, G.
1994-01-01
Lead used for shielding is often surface contaminated with radioisotopes and is therefore a RCRA D008 mixed waste. The technology-based standard for treatment is macroencapsulation. However, decontaminating and recycling the clean lead is a more attractive solution. Los Alamos National Laboratory decontaminates material and equipment contaminated with radioisotopes. Decontaminating lead poses special problems because of the RCRA hazard classification and the size of the inventory, now about 50 tons and likely to grow substantially of planned decommissioning operations. Thus lead, in the form of bricks and other shield shapes, is surface contaminated with fission products. One of the best methods for contaminated lead is removing the superficial layer of contamination with an abrasive medium under pressure. For lead, a mixture of alumina with water and air at about 40 psig rapidly and effectively decontaminates the lead. The abrasive medium is sprayed onto the lead in a scaled-off area. The slurry of abrasive and particles of lead falls through a floor and is collected in a sump. A pump sends the slurry mixture back to the spray gun, creating a continuous process. The process generates small volumes of lead slurry that can be solidified and, because it passes the TCLP, is not a mixed waste. The decontaminated lead can be released for recycling
Development of acidic processes for decontaminating LMFBR components
Energy Technology Data Exchange (ETDEWEB)
Hill, E F [Rockwell International, Atomics International Division, Canoga Park (United States); Colburn, R P; Lutton, J M; Maffei, H P [Hanford Engineering Development Laboratory, Richland (United States)
1978-08-01
The objective of the DOE decontamination program is to develop a well characterized chemical decontamination process for application to LMFBR primary system components that subsequently permits contact maintenance and allows requalification of the components for reuse in reactors. The paper describes the subtasks of deposit characterization, development of requalification and process acceptance criteria, development of process evaluation techniques and studies which led to a new acidic process for decontaminating 304 stainless steel hot leg components.
Development of acidic processes for decontaminating LMFBR components
International Nuclear Information System (INIS)
Hill, E.F.; Colburn, R.P.; Lutton, J.M.; Maffei, H.P.
1978-01-01
The objective of the DOE decontamination program is to develop a well characterized chemical decontamination process for application to LMFBR primary system components that subsequently permits contact maintenance and allows requalification of the components for reuse in reactors. The paper describes the subtasks of deposit characterization, development of requalification and process acceptance criteria, development of process evaluation techniques and studies which led to a new acidic process for decontaminating 304 stainless steel hot leg components
Investigation of electro-kinetic methods for soil decontamination
International Nuclear Information System (INIS)
Shabanova, A.N.
2000-01-01
The choices of effective methods for ecological system decontamination, their perfection and introduction into practical use have been actual tasks for the Ural region. The objective of this work has been to study the potentials of electrical kinetics method of ISOTRON Corporation (US) for decontamination of the Urals soils. Results obtained have shown the method proposed to be usable for decontaminating some types of soils from strontium and plutonium; it is low effective for decontamination in the area of South-Urals radioactive plume. Thus, a low effectiveness can be expected in podsolic and leached laterite characterized by a high content of loamy sand and sandy soils, as well as for sobby-podsolic ones. The method can be promising for decontamination of soils and wastes from chemical contaminants, such as Zn, Ni, Cu, Pb, Hg, and others. Important advantages of this method compared to others have been its simplicity, small amount of wastes, and feasibility of decontamination in areas difficult to access. (authors)
Radioactive decontamination through UV laser
International Nuclear Information System (INIS)
Delaporte, Ph.; Gastaud, M.; Sentis, M.; Uteza, O.; Marine, W.; Thouvenot, P.; Alcaraz, J.L.; Le Samedy, J.M.; Blin, D.
2003-01-01
A device allowing the radioactive decontamination of metal surfaces through the use of a pulsed UV laser has been designed and tested. This device is composed of a 1 kW excimer laser linked to a bundle of optic fibers and of a system to recover particles and can operate in active zones. Metal surfaces have the peculiarities to trap radio-elements in a superficial layer of oxide that can be eaten away by laser radiation. Different contaminated metals (stainless steels, INCONEL and aluminium) issued from the nuclear industry have been used for the testing. The most important contaminants were 60 Co, 137 Cs, 154-155 Eu and 125 Sb. The ratio of decontamination was generally of 10 and the volume of secondary wastes generating during the process was very low compared with other decontamination techniques. A decontamination speed of 1 m 2 /h has been reached for aluminium. The state of the surface is an important parameter because radio-elements trapped in micro-cracks are very difficult to remove. (A.C.)
Decontaminating agents and decontamination processes for nuclear industry and for plant demolition
International Nuclear Information System (INIS)
Henning, Klaus; Gojowczyk, Peter
2012-01-01
Decontamination of surfaces of materials in nuclear facilities or in nuclear power plants under demolition can be carried out successfully if surface treatment is performed by dipping or in an ultrasonic bath by alternating between alkaline and acid baths with intermediate rinsing in demineralized water. Decontaminating aluminium surfaces sensitive to corrosion requires further treatment in an ultrasonic bath, after the first 2 ultrasonic baths, with a weak alkaline decontaminating agent. This applies alike to components to be decontaminated for re-use and parts of materials to be disposed of. The decontamination action depends on the surfaces either being free from corrosion or else showing pronounced corrosion. (orig.)
Lessons Learned from Decontamination Experiences
Energy Technology Data Exchange (ETDEWEB)
Sorensen, JH
2000-11-16
This interim report describes a DOE project currently underway to establish what is known about decontamination of buildings and people and the procedures and protocols used to determine when and how people or buildings are considered ''clean'' following decontamination. To fulfill this objective, the study systematically examined reported decontamination experiences to determine what procedures and protocols are currently employed for decontamination, the timeframe involved to initiate and complete the decontamination process, how the contaminants were identified, the problems encountered during the decontamination process, how response efforts of agencies were coordinated, and the perceived social psychological effects on people who were decontaminated or who participated in the decontamination process. Findings and recommendations from the study are intended to aid decision-making and to improve the basis for determining appropriate decontamination protocols for recovery planners and policy makers for responding to chemical and biological events.
Oxidation of Ce(III) in Foam Decontaminant by Ozone
Energy Technology Data Exchange (ETDEWEB)
Jung, Chong Hun; Yoon, I. H.; Choi, W. K.; Moon, J. K.; Yang, H. B. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Lee, J. S. [Gachon University, Seongnam (Korea, Republic of)
2016-10-15
A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing cerium(III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can decompose immediately. The ozonation treatment of Ce(III) in foam decontaminant containing a surfactant is necessary for the effective regeneration of Ce(III). Thus, the present study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) into Ce(IV) in the nanoparticle-based foam decontaminant containing surfactant. This study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) to Ce(IV) in nanoparticle-based foam decontaminant containing a TBS surfactant. The oxidation conversion rate of Ce(III) was increased with an increase in the flow rate of the gas mixture and ozone injection amount. The oxidation time required for the 100% oxidation conversion of Ce(III) to Ce(IV) at a specific ozone injection amount can be predicted from these experimental data.
Oxidation of Ce(III) in Foam Decontaminant by Ozone
International Nuclear Information System (INIS)
Jung, Chong Hun; Yoon, I. H.; Choi, W. K.; Moon, J. K.; Yang, H. B.; Lee, J. S.
2016-01-01
A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing cerium(III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can decompose immediately. The ozonation treatment of Ce(III) in foam decontaminant containing a surfactant is necessary for the effective regeneration of Ce(III). Thus, the present study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) into Ce(IV) in the nanoparticle-based foam decontaminant containing surfactant. This study was undertaken to determine the optimal conditions for ozonation treatment in the regeneration of Ce(III) to Ce(IV) in nanoparticle-based foam decontaminant containing a TBS surfactant. The oxidation conversion rate of Ce(III) was increased with an increase in the flow rate of the gas mixture and ozone injection amount. The oxidation time required for the 100% oxidation conversion of Ce(III) to Ce(IV) at a specific ozone injection amount can be predicted from these experimental data
Reboulet, James; Cunningham, Robert; Gunasekar, Palur G; Chapman, Gail D; Stevens, Sean C
2009-02-01
A whole body inhalation study of mixed jet fuel vapor and its aerosol necessitated the development of a method for preparing vapor only standards from the neat fuel. Jet fuel is a complex mixture of components which partitions between aerosol and vapor when aspirated based on relative volatility of the individual compounds. A method was desired which could separate the vapor portion from the aerosol component to prepare standards for the calibration of infrared spectrophotometers and a head space gas chromatography system. A re-circulating loop system was developed which provided vapor only standards whose composition matched those seen in an exposure system. Comparisons of nominal concentrations in the exposure system to those determined by infrared spectrophotometry were in 92-95% agreement. Comparison of jet fuel vapor concentrations determined by infrared spectrophotometry compared to head space gas chromatography yielded a 93% overall agreement in trial runs. These levels of agreement show the loop system to be a viable method for creating jet fuel vapor standards for calibrating instruments.
Decontamination of body surface
International Nuclear Information System (INIS)
Harase, Chieko.
1989-01-01
There are two important points for an effective application of decontamination procedures. One is the organizing method of responsible decontamination teams. The team should be directed by medical doctor with the knowledge of decontamination of radionuclides. The other point is the place of application of the decontamination. Hospitals and clinics, especially with a department of nuclear medicine, or specialized units such as an emergency medical center are preferable. Before decontamination procedures are initiated, adequate monitoring of the body surface should be undertaken by a competent person in order to demarcate the areas which are contaminated. There are fundamental principles which are applicable to all decontamination procedures. (1) Precautions must always be taken to prevent further spread of contamination during decontamination operations. (2) Mild decontamination methods should be tried before resorting to treatment which can damage the body surface. The specific feature of each contamination varies widely in radionuclides involved, place and area of the contamination, condition of the contaminated skin such as whether the skin is wounded or not, and others. Soap and water are usually good detergents in most cases. If they fail, orange oil cream (SUPERDECONCREAM, available from Tokyo Engineering Co.) specially prepared for decontamination of radionuclides of most fission and corrosion products may be used. Contaminated hair should be washed several times with an efficient shampoo. (author)
International Nuclear Information System (INIS)
Severa, J.; Bar, J.; Grujbar, V.
1978-01-01
Samples of five polypropylene-based man-made fabrics were studied with regard to the degree of contamination and possibilities of decontamination in order to assess their suitability as material for protective clothing in the nuclear industry. The contamination degree of the fabrics in an aqueous solution of a fission product mixture was found to be low. Soaking in a mixture of the Sapon detergent and sodium hexametaphosphate at a concentration of both materials of 1 g/l with subsequent washing in a solution of the Zenit detergent at a concentration of 3 g/l was suggested as the most suitable decontamination procedure. It reduces the initial contamination by almost 99%. (Z.M.)
Decontamination systems information and research program. Quarterly report, January 1996--March 1996
Energy Technology Data Exchange (ETDEWEB)
NONE
1996-04-01
West Virginia University (WVU) and the US Department of Energy, Morgantown Energy Technology Center (DOE/METC) entered into a Cooperative Agreement in August 1992 titled {open_quotes}Decontamination Systems Information and Research Programs{close_quotes} (DOE Instrument No.: DE-FC21-92MC29467). Requirements stipulated by the Agreement require WVU to submit quarterly Technical Progress reports. This report contains the efforts of the research projects comprising the Agreement for the 1st calendar quarter of 1996. For the period January 1 through December 31, 1996 twelve projects have been selected for funding, and the Kanawha Valley will continue under a no-cost extension. Three new projects have also been added to the program. This document describes these projects involving decontamination, decommissioning and remedial action issues and technologies.
Decontamination of two filter boxes after a fire
International Nuclear Information System (INIS)
Cerre, P.; Mestre, E.; Lafitte, T.
1961-01-01
As a primary filter of the venting system caught fire in a hot cell of the Laboratory of Examination of Irradiated Fuels, this filter (as well as the secondary filter) has been removed, wrapped in polyvinyl sheets, and transported into the decontamination station. The authors report the details of the handling and decontamination operations: modifications to the station arrangement, measures of radiation protection, decontamination and measurements, observations made when disassembling the filter and filter-boxes [fr
Equipment decontamination: A brief survey of the DOE complex
International Nuclear Information System (INIS)
Conner, C.; Chamberlain, D.B.; Chen, L.; Vandegrift, G.F.
1995-03-01
Deactivation at DOE facilities has left a tremendous amount of contaminated equipment behind. In-situ methods are needed to decontaminate the interiors of the equipment sufficiently to allow either free release or land disposal. A brief survey was completed of the DOE complex on their needs for equipment decontamination with in-situ technology to determine (1) the types of contamination problems within the DOE complex, (2) decontamination processes that are being used or are being developed within the DOE, and (3) the methods that are available to dispose of spent decontamination solutions. In addition, potential sites for testing decontamination methods were located. Based on the information obtained from these surveys, the Rocky Flats Plant and the Idaho National Engineering Laboratory appear to be best suited to complete the initial testing of the decontamination processes
Vapor Delivery Systems for the Study of the Effects of Reformate Gas Impurities in HT-PEM Fuel Cells
DEFF Research Database (Denmark)
Araya, Samuel Simon; Kær, Søren Knudsen; Andreasen, Søren Juhl
2011-01-01
, impurities in the reformate gas produced from methanol steam reforming can affect the performance and durability of fuel cells. In this paper different vapor delivery systems, intended to assist in the study of the effects of some of the impurities, are described and compared with each other. A system based...... on a pump and electrically heated evaporator was found to be more suitable for the typical flow rates involved in the anode feed of an H3PO4/PBI based HT-PEMFC unit cell assembly. Test stations composed of vapor delivery systems and mass flow controllers for testing the effects of methanol slip, water vapor...
Intervention and decontamination of hardware contaminated by tritium
International Nuclear Information System (INIS)
Cerre, Pierre; Mestre, Emile
1964-10-01
This report first describes the intervention process for teams intervening, either in case of accident or to modify or repair installations in which tritium is handled, i.e. in both cases in a contaminated atmosphere. Three main aspects are addressed: how to prepare and insulate the work place from the rest of the installation, how to protect the intervening personnel, and how to perform decontamination. The authors then present the various available decontamination techniques: decontamination bath at different temperatures and use of different chemical solutions at different temperatures, the degassing technique (temperature increase and vacuum, temperature hold during 30 to 45 minutes, return to atmospheric pressure), and mercury-based decontamination
Decontamination of Belarus research reactor installation by strippable coatings
International Nuclear Information System (INIS)
Voronik, N.I.; Shatilo, N.N.
2002-01-01
The goal of this study was to develop new strippable coatings using water-based solutions of polyvinyl alcohol and active additives for decontamination of research reactor equipment. The employment of strippable coatings makes it possible to minimize the quantity of liquid radioactive waste. The selection of strippable decontaminating coatings was carried out on the basis of general requirements to decontaminating solutions: successfully dissolve corrosion deposits; ensure the desorption of radionuclides from the surfaces and the absence of resorption; introduce minimal corrosion effect of construction materials; to be relatively cheap and available in reagents. The decontaminating ability and adhesion properties of these coatings depending on metal and deposit sorts were investigated. Research on the chemical stability of solid wastes was carried out. The data obtained were the base for recommendations on waste management procedure for used films and pastes. A full-scale case-study analysis was performed for comparing strippable coatings with decontaminating solutions. (author)
Atmospheric-pressure plasma decontamination/sterilization chamber
Herrmann, Hans W.; Selwyn, Gary S.
2001-01-01
An atmospheric-pressure plasma decontamination/sterilization chamber is described. The apparatus is useful for decontaminating sensitive equipment and materials, such as electronics, optics and national treasures, which have been contaminated with chemical and/or biological warfare agents, such as anthrax, mustard blistering agent, VX nerve gas, and the like. There is currently no acceptable procedure for decontaminating such equipment. The apparatus may also be used for sterilization in the medical and food industries. Items to be decontaminated or sterilized are supported inside the chamber. Reactive gases containing atomic and metastable oxygen species are generated by an atmospheric-pressure plasma discharge in a He/O.sub.2 mixture and directed into the region of these items resulting in chemical reaction between the reactive species and organic substances. This reaction typically kills and/or neutralizes the contamination without damaging most equipment and materials. The plasma gases are recirculated through a closed-loop system to minimize the loss of helium and the possibility of escape of aerosolized harmful substances.
Kauppinen, Ari; Ikonen, Jenni; Pursiainen, Anna; Pitkänen, Tarja; Miettinen, Ilkka T
2012-09-01
A contaminated drinking water distribution network can be responsible for major outbreaks of infections. In this study, two chemical decontaminants, peracetic acid (PAA) and chlorine, were used to test how a laboratory-scale pipeline system can be cleaned after simultaneous contamination with human adenovirus 40 (AdV40) and Escherichia coli. In addition, the effect of the decontaminants on biofilms was followed as heterotrophic plate counts (HPC) and total cell counts (TCC). Real-time quantitative polymerase chain reaction (qPCR) was used to determine AdV40 and plate counting was used to enumerate E. coli. PAA and chlorine proved to be effective decontaminants since they decreased the levels of AdV40 and E. coli to below method detection limits in both water and biofilms. However, without decontamination, AdV40 remained present in the pipelines for up to 4 days. In contrast, the concentration of cultivable E. coli decreased rapidly in the control pipelines, implying that E. coli may be an inadequate indicator for the presence of viral pathogens. Biofilms responded to the decontaminants by decreased HPCs while TCC remained stable. This indicates that the mechanism of pipeline decontamination by chlorine and PAA is inactivation rather than physical removal of microbes.
International Nuclear Information System (INIS)
Hirose, Emiko; Kanesaki, Ken.
1995-01-01
The decontamination sheet of the present invention is formed by applying an adhesive on one surface of a polymer sheet and releasably appending a plurality of curing sheets. In addition, perforated lines are formed on the sheet, and a decontaminating agent is incorporated in the adhesive. This can reduce the number of curing operation steps when a plurality steps of operations for radiation decontamination equipments are performed, and further, the amount of wastes of the cured sheets, and operator's exposure are reduced, as well as an efficiency of the curing operation can be improved, and propagation of contamination can be prevented. (T.M.)
MOBILE PHONES– DO WE NEED DECONTAMINATION?
Directory of Open Access Journals (Sweden)
Ketaki Prakash Ghatole
2018-01-01
Full Text Available BACKGROUND Mobile phones have become a necessity in the present scenario. They are extensively used for communication, internet, images, education, you tube, banking, for sharing reports, X-rays in healthcare settings. On the other hand they are reported to be contaminated by micro-organisms and may act as source of infection. In our study we analysed the mobile phones of healthcare workers (HCW and college students for microbial contamination and also efficacy of sanitizers, wet wipes for decontamination. MATERIALS AND METHODS A total of 220 swabs were collected from 110 mobile phones of HCWs and 110 students. Swabs were cultured on 5% sheep blood agar; MacConkey agar and isolates were identified by standard protocol. RESULTS 91.8% of students and 89.1% of HCWs mobiles were contaminated. Organisms like Staphylococcus aureus, CONS, E. coli, Klebsiella aerogenes were isolated. HCWs mobiles showed higher number of potential pathogens. Decontamination by absolute alcohol, alcohol-based hand sanitizers decontaminated 96% of the mobile phones. Nonalcohol-based hand sanitizers and wet wipes were able to decontaminate 88% and 96% of the mobiles respectively. CONCLUSION Mobile phones of healthcare workers and also students were contaminated. Absolute alcohol could clean 96% mobiles of HCWs and 92% of students. Alcohol based hand sanitizers eliminated the organisms (96% as against non-alcohol-based sanitizers. (88%. It was also observed that wet wipes were effective in students’ groups. (96%.
International Nuclear Information System (INIS)
Tsujimura, Hiroshi; Ono, Shigeki; Tada, Nobuo; Tamai, Yasumasa; Okada, Masaya; Kurihara, Masayuki; Onuki, Toyomitsu; Toyota, Seiichi
1998-01-01
Before contamination of materials to be decontaminated, a surface of a region where a strippable paint is to be coated is smoothed by an epoxy resin previously. Then, a waterproof sheet is extended to the material to be decontaminated, and the strippable paint is applied to the periphery or the entire surface of the sheet. In order to facilitate peeling, the strippable paint is not applied to a portion of the outer circumference of the sheet. Even if the contaminating circumstance is an air atmosphere or a liquid such as reactor water, since the sheet itself has waterproofness and the strippable paint excellent in gas and water tightness is applied to the periphery, contamination is eliminated. When decontaminating the material to be decontaminated having contaminated surfaces, if the sheet for the start of peeling is picked up and the sheet is peeled, the strippable paint at the periphery thereof can be peeled off together with the sheet. (N.H.)
Energy Technology Data Exchange (ETDEWEB)
Tsujimura, Hiroshi; Ono, Shigeki; Tada, Nobuo; Tamai, Yasumasa; Okada, Masaya; Kurihara, Masayuki [Hitachi Ltd., Tokyo (Japan); Onuki, Toyomitsu; Toyota, Seiichi
1998-10-27
Before contamination of materials to be decontaminated, a surface of a region where a strippable paint is to be coated is smoothed by an epoxy resin previously. Then, a waterproof sheet is extended to the material to be decontaminated, and the strippable paint is applied to the periphery or the entire surface of the sheet. In order to facilitate peeling, the strippable paint is not applied to a portion of the outer circumference of the sheet. Even if the contaminating circumstance is an air atmosphere or a liquid such as reactor water, since the sheet itself has waterproofness and the strippable paint excellent in gas and water tightness is applied to the periphery, contamination is eliminated. When decontaminating the material to be decontaminated having contaminated surfaces, if the sheet for the start of peeling is picked up and the sheet is peeled, the strippable paint at the periphery thereof can be peeled off together with the sheet. (N.H.)
Experience Practices on Decontamination Activity in NPP Decommissioning
Energy Technology Data Exchange (ETDEWEB)
Yoon, Suk Bon; Kim, Jeongju; Sohn, Wook [Korea Hydro and Nuclear Power Co., Daejeon (Korea, Republic of)
2016-10-15
Decommissioning of a nuclear power plant (NPP) involves various technical and administrative activities for a utility to terminate its license, which allows the plant site to be released from the regulatory control (site release). Decontamination activity in NPP decommissioning is one of the main technical activities to be performed during the decommissioning. The decontamination at decommissioning sites is usually performed due to several reasons such as reducing personnel dose and disposal costs, and cleanup to meet license termination requirements by using physical or chemical removal techniques proven through the previous experience practices. This paper introduces the best and worst practices for the decontamination activities collected from the decommissioning operational experiences through the implementation of nuclear decommissioning projects around the world. Review of the experiences of decontamination shows that it is important to conduct an advanced planning for optimized implementation of decontamination taking into considering site specific conditions such as operating time, reactor type, system, and so on. Also, a review of newer decontamination methods is necessary to safely and economically decommission the nuclear facility.
International Nuclear Information System (INIS)
Knaack, Michael
2016-01-01
This paper describes the influence of several decontamination techniques on the decommissioning of nuclear facilities. There are different kinds of decontamination methods like mechanical and chemical processes. The techniques specified, and their potential to change measured characteristics like the isotope vector of the contamination is demonstrated. It is common for all these processes, that the contamination is removed from the surface. Slightly adhered nuclides can be removed more effectively than strongly sticking nuclides. Usually a mixture of these nuclides forms the contamination. Problematically any kind of decontamination will influence the nuclide distribution and the isotope vector. On the one hand it is helpful to know the nuclide distribution and the isotope vector for the radiological characterization of the nuclear facility and on the other hand this information will be changed in the decontamination process. This is important especially for free release procedures, radiation protection and waste management. Some questions on the need of decontamination have been discussed. (authors)
Chemical and mechanical decontamination processes to minimize secondary waste decommissioning
International Nuclear Information System (INIS)
Enda, M.; Ichikawa, N.; Yaita, Y.; Kanasaki, T.; Sakai, H.
2008-01-01
In the decommissioning of commercial nuclear reactors in Japan, prior to the dismantling of the nuclear power plants, there are plans to use chemical techniques to decontaminate reactor pressure vessels (RPVs), internal parts, primary loop recirculation systems (PLRs), reactor water clean up systems (RWCUs), etc., so as to minimize radiation sources in the materials to be disposed of. After dismantling the nuclear power plants, chemical and mechanical decontamination techniques will then be used to reduce the amounts of radioactive metallic waste. Toshiba Corporation has developed pre-dismantling and post-dismantling decontamination systems. In order to minimize the amounts of secondary waste, the T-OZON process was chosen for decontamination prior to the dismantling of nuclear power plants. Dismantling a nuclear power plant results in large amounts of metallic waste requiring decontamination; for example, about 20,000 tons of such waste is expected to result from the dismantling of a 110 MWe Boiling Water Reactor (BWR). Various decontamination methods have been used on metallic wastes in preparation for disposal in consideration of the complexity of the shapes of the parts and the type of material. The materials in such nuclear power plants are primarily stainless steel and carbon steel. For stainless steel parts having simple shapes, such as plates and pipes, major sources of radioactivity can be removed from the surface of the parts by bipolar electrolysis (electrolyte: H 2 SO 4 ). For stainless steel parts having complicated shapes, such as valves and pumps, major sources of radioactivity can be removed from the surfaces by redox chemical decontamination treatments (chemical agent: Ce(IV)). For carbon steel parts having simple shapes, decontamination by blasting with zirconia grit is effective in removing major sources of radioactivity at the surface, whereas for carbon steel parts having complicated shapes, major sources of radioactivity can be removed from
Fate of sulfur mustard on soil: Evaporation, degradation, and vapor emission.
Jung, Hyunsook; Kah, Dongha; Chan Lim, Kyoung; Lee, Jin Young
2017-01-01
After application of sulfur mustard to the soil surface, its possible fate via evaporation, degradation following absorption, and vapor emission after decontamination was studied. We used a laboratory-sized wind tunnel, thermal desorber, gas chromatograph-mass spectrometry (GC-MS), and 13 C nuclear magnetic resonance ( 13 C NMR) for systematic analysis. When a drop of neat HD was deposited on the soil surface, it evaporated slowly while being absorbed immediately into the matrix. The initial evaporation or drying rates of the HD drop were found to be power-dependent on temperature and initial drop volume. Moreover, drops of neat HD, ranging in size from 1 to 6 μL, applied to soil, evaporated at different rates, with the smaller drops evaporating relatively quicker. HD absorbed into soil remained for a month, degrading eventually to nontoxic thiodiglycol via hydrolysis through the formation of sulfonium ions. Finally, a vapor emission test was performed for HD contaminant after a decontamination process, the results of which suggest potential risk from the release of trace chemical quantities of HD into the environment. Copyright © 2016 Elsevier Ltd. All rights reserved.
Decontamination of radionuclides on construction materials
International Nuclear Information System (INIS)
Samuleev, P.V.; Andrews, W.S.; Creber, K.A.M.; Velicogna, D.
2013-01-01
A wide variety of materials can become contaminated by radionuclides, either from a terrorist attack or an industrial or nuclear accident. The final disposition of these materials depends, in large part, on the effectiveness of decontamination measures. This study reports on investigations into the decontamination of a selection of building materials. The aim has been to find an effective, easy-to-use and inexpensive decontamination system for radionuclides of cesium and cobalt, considering both the chemical and physical nature of these potential contaminants. The basic method investigated was surface washing, due to its ease and simplicity. In the present study, a basic decontamination formulation was modified by adding isotope-specific sequestering agents, to enhance the removal of cesium(I) and cobalt(II) from such construction materials as concrete, marble, aluminum and painted steel. Spiking solutions contained 134 Cs or 60 Co, which were prepared by neutron activation in the SLOWPOKE-2 nuclear reactor facility at the Royal Military College of Canada. Gamma spectroscopy was used to determine the decontamination efficiency. The results showed that the addition of sequestering agents generally improved the radiological decontamination. Although the washing of both cesium and cobalt from non-porous materials, such as aluminum and painted steel, achieved a 90-95 % removal, the decontamination of concrete and marble was more challenging, due to the porous nature of the materials. Nevertheless, the removal efficiency from 6-year-old concrete increased from 10 % to approximately 50 % for cobalt(II), and from 18 to 55 % for cesium(I), with the use of isotope binding agents, as opposed to a simple water wash. (author)
Decontamination device for pipeline
International Nuclear Information System (INIS)
Harashina, Heihachi.
1994-01-01
Pipelines to be decontaminated are parts of pipelines contaminated with radioactive materials, and they are connected to a fluid transfer means (for example, a bladeless pump) and a ball collector by way of a connector. The fluid of a mixture of chemical decontaminating liquid and spheres is sent into pipelines to be decontaminated. The spheres are, for example, heat resistant porous hard or soft rubber spheres. The fluid discharged from the pipelines to be decontaminated are circulated by way of bypassing means. The inner surface of the pipelines is decontaminated by the circulation of the fluid. When the bypass means is closed, the fluid discharged from the pipelines to be decontaminated is sent to the ball collector, and the spheres are captured by a hopper. Further, the liquid is sent to the filtrating means to filter the chemical contaminating liquid, and sludges contained in the liquid are captured. (I.N.)
Polyoxometalate-based Catalysts for Toxic Compound Decontamination and Solar Energy Conversion
Guo, Weiwei
Polyoxometalates (POMs) have been attracting interest from researchers in the fields of Inorganic Chemistry, Physical Chemistry, Biomolecular Chemistry, etc. Their unique structures and properties render them versatile and facilitate applications in medicine, magnetism, electrochemistry, photochemistry and catalysis. In particular, toxic compound (chemical warfare agents (CWAs) and toxic industrial compounds (TICs)) decontamination and solar energy conversion by POM-based materials have becoming promising and important research areas that deserve much attention. The focus of this thesis is to explore the structural features of POMs, to develop POM-based materials and to investigate their applications in toxic compound decontamination and solar energy conversion. The first part of this thesis gives a general introduction on the history, structures, properties and applications of POMs. The second part reports the synthesis, structures, and reactivity of different types of POMs in the destruction of TICs and CWAs. Three tetra-n-butylammonium (TBA) salts of polyvanadotungstates, [n-Bu4N]6[ PW9V3], [n-Bu4N] 5H2PW8V4O40 (PW 8V4), [n-Bu4N]4H 5PW6V6O40· 20H2O (PW6V6) are discussed in detail. These vanadium-substituted Keggin type POMs show effective activity for the aerobic oxidation of formaldehyde (a major TIC and human-environment carcingen) to formic acid under ambient conditions. Moreover, two types of POMs have also been developed for the removal of CWAs and/or their simulants. Specifically, a layered manganese(IV)-containing heteropolyvanadate with a 1:14 Stoichiometry, K4Li2[MnV14O40]˙21H2 O has been prepared. Its catalytic activity for oxidative removal of 2-chloroethyl ethyl sulfide (a mustard simulant) is discussed. The second type of POM developed for decontamination of CWAs and their simulants is the new one-dimensional polymeric polyniobate (P-PONb), K12[Ti 2O2][GeNb12O40]˙19H2O (KGeNb). The complex has been applied to the decontamination of a wide range
Experience in decontamination of the equipment of NPP's with the WWER-440 reactors
International Nuclear Information System (INIS)
Balaban-Irmenin, Yu.V.
1981-01-01
Different methods of decontamination at NPPs are briefly characterized. Decontamination of the removable part of the main circulation pump (MCP) of the WWER-440 reactor is considered as an example of removable equipment decontamination. A design of the decontamination bath of the removable MCP elements and the applied chemical agents are described. A decontamination flowsheet of the Novovoronezh NPP steam generator (SG) is considered as an example of the autonomic decontamination system. The SG decontamination modes, principal flowsheets of a hydromonitor, steam-ejection sprayer and steam-emulsion device are described [ru
Decontamination trade study for the Light Duty Utility Arm
International Nuclear Information System (INIS)
Rieck, R.H.
1994-01-01
Various methods were evaluated for decontaminating the Light Duty Utility Arm (LDUA). Physical capabilities of each method were compared with the constraints and requirements for the LDUA Decontamination System. Costs were compared and a referred alternative was chosen
Pottage, Thomas; Walker, James; Bennett, Allan; Vrublevskis, John; Hovland, Scott
This study, funded by the European Space Agency (ESA) and undertaken by the Health Protec-tion Agency, UK supported by Systems Engineering and Assessment Ltd., was devised to select suitable current decontamination technologies for development for future manned missions to the Moon and Mars. There is a requirement to decontaminate the habitat module due to the concerns about astronaut ill health, microbial deterioration of materials and potential forward contamination in the case of Mars. In the case of the MIR space station, biodeterioration of components and materials occurred, and dangerous levels of airborne microorganisms were detected during air sampling procedures which lead to the introduction of microbial exposure limits (as MORD SSP 50260) to ensure the health of the crew. COSPAR planetary protection guidelines highlight the need to reduce any potential forward or backwards contamination issues that may occur through the use of Extra Vehicular Activity (EVA) suits whilst on Mars. Decontamination of the suit exterior must be completed before any EVA activity on Mars, whilst a further decontamination cycle must be completed after entry to the airlock following EVA. Technologies and techniques have also been investigated for the microbial reduction of the interior surfaces of the EVA suit to stop biodeterioration of the materials and protect the user from pathogenic microbe accumulation. The first work package reviewed the systems description and requirements as detailed in the statement of work. The requirements were broken down into 12 further requirement sections, where they were updated and expanded, resulted in Technical Note (TN) 1 which was then used as the base document for WP2 and WP3. WP2 investigated the current technologies available for the decontamination of the habitat module interior on missions of up to 6 months and missions that have durations of greater than 6 months. A comprehensive review was carried out for the different methods that
Energy Technology Data Exchange (ETDEWEB)
Yasutaka, T.; Naito, W. [National Institute of Advanced Industrial Science and Technology (Japan)
2014-07-01
Despite the enormous cost associated with radiation decontamination, almost no quantitative assessment has been performed on the relationship between the potential reduction in long-term radiation exposure and the costs of the various decontamination strategies considered for the decontamination areas in Fukushima. In order to establish effective and pragmatic decontamination strategies for use in the radiation contaminated areas in Fukushima, a holistic approach for assessing decontamination strategies, their costs, and long-term external radiation doses is needed. The objective of the present study is to evaluate the cost and effectiveness of decontamination scenarios in the decontamination areas in Fukushima in regard to external radiation exposure. The choice of decontamination strategies in the decontamination areas should be based on a comprehensive analysis of multiple attributes such as radiological, economic, and socio-psychological attributes. The cost and effectiveness of the different decontamination strategies is not sole determinant of the decontamination strategies of the special decontamination area but is one of the most important attributes when making the policy decision. In the current study, we focus on radiological and economic attributes in determining decontamination strategies. A geographical information system (GIS) was used to relate the predicted external dose in the affected areas to the number of potential inhabitants and the land use in the areas. A comprehensive review of the costs of various decontamination methods was conducted as part of the analysis. The results indicate that aerial decontamination in the special decontamination areas in Fukushima would be effective for reducing the air dose rate to the target level in a short period of time in some but not all of the areas. In a standard scenario, the analysis of cost suggests that decontamination costs of decontamination in Fukushima was estimated to be up to approximately 5
Particle Separation of Non-Decontamination Soil using Attrition and Washing
International Nuclear Information System (INIS)
Koo, Daeseo; Sung, Hyun-Hee; Kim, Seung-Soo; Hong, Sang Bum; Seo, Bum Kyoung; Choi, Jong-Won
2017-01-01
In this study, to improve the decontamination efficiency of uranium soil, a preliminary experiment on the particle separation of non-decontamination soil was carried out using attrition and washing. The characteristics of the attrition and washing system are investigated. A conditional experiment on particle separation of non-decontamination soil will be performed. A preliminary experiment on the particle separation of non-decontamination soil was carried out to improve the decontamination efficiency of uranium soil. This experiment was performed with the ratio of soil to water (1:4) for the particle separation of non-decontamination soil. The operations of all equipment such as attrition scrubber, ultrasonic reaction, vibrating screen, and hydro-cyclone were conducted and confirmed. In the future, the additional experiments will be conducted for optimal experimental condition.
On-Site Decontamination System for Liquid Low Level Radioactive Waste - 13010
Energy Technology Data Exchange (ETDEWEB)
OSMANLIOGLU, Ahmet Erdal [Cekmece Nuclear Research and Training Center, Kucukcekmece Istanbul (Turkey)
2013-07-01
This study is based on an evaluation of purification methods for liquid low-level radioactive waste (LLLW) by using natural zeolite. Generally the volume of liquid low-level waste is relatively large and the specific activity is rather low when compared to other radioactive waste types. In this study, a pilot scale column was used with natural zeolite as an ion exchanger media. Decontamination and minimization of LLLW especially at the generation site decrease operational cost in waste management operations. Portable pilot scale column was constructed for decontamination of LLW on site. Effect of temperature on the radionuclide adsorption of the zeolite was determined to optimize the waste solution temperature for the plant scale operations. In addition, effect of pH on the radionuclide uptake of the zeolite column was determined to optimize the waste solution pH for the plant scale operations. The advantages of this method used for the processing of LLLW are discussed in this paper. (authors)
Off-site consequences of radiological accidents: methods, costs and schedules for decontamination
International Nuclear Information System (INIS)
Tawil, J.J.; Bold, F.C.; Harrer, B.J.; Currie, J.W.
1985-08-01
This report documents a data base and a computer program for conducting a decontamination analysis of a large, radiologically contaminated area. The data base, which was compiled largely through interviews with knowledgeable persons both in the public and private sectors, consists of the costs, physical inputs, rates and contaminant removal efficiencies of a large number of decontamination procedures. The computer program utilizes this data base along with information specific to the contaminated site to provide detailed information that includes the least costly method for effectively decontaminating each surface at the site, various types of property losses associated with the contamination, the time at which each subarea within the site should be decontaminated to minimize these property losses, the quantity of various types of labor and equipment necessary to complete the decontamination, dose to radiation workers, the costs for surveying and monitoring activities, and the disposal costs associated with radiological waste generated during cleanup. The program and data base are demonstrated with a decontamination analysis of a hypothetical site. 39 refs., 24 figs., 155 tabs
Off-site consequences of radiological accidents: methods, costs and schedules for decontamination
Energy Technology Data Exchange (ETDEWEB)
Tawil, J.J.; Bold, F.C.; Harrer, B.J.; Currie, J.W.
1985-08-01
This report documents a data base and a computer program for conducting a decontamination analysis of a large, radiologically contaminated area. The data base, which was compiled largely through interviews with knowledgeable persons both in the public and private sectors, consists of the costs, physical inputs, rates and contaminant removal efficiencies of a large number of decontamination procedures. The computer program utilizes this data base along with information specific to the contaminated site to provide detailed information that includes the least costly method for effectively decontaminating each surface at the site, various types of property losses associated with the contamination, the time at which each subarea within the site should be decontaminated to minimize these property losses, the quantity of various types of labor and equipment necessary to complete the decontamination, dose to radiation workers, the costs for surveying and monitoring activities, and the disposal costs associated with radiological waste generated during cleanup. The program and data base are demonstrated with a decontamination analysis of a hypothetical site. 39 refs., 24 figs., 155 tabs.
Thors, L; Koch, M; Wigenstam, E; Koch, B; Hägglund, L; Bucht, A
2017-08-01
The decontamination efficacy of four commercially available skin decontamination products following exposure to the nerve agent VX was evaluated in vitro utilizing a diffusion cell and dermatomed human skin. The products included were Reactive Skin Decontamination Lotion (RSDL), the Swedish decontamination powder 104 (PS104), the absorbent Fuller's Earth and the aqueous solution alldecontMED. In addition, various decontamination procedures were assessed to further investigate important mechanisms involved in the specific products, e.g. decontamination removal from skin, physical removal by sponge swabbing and activation of degradation mechanisms. The efficacy of each decontamination product was evaluated 5 or 30 min after dermal application of VX (neat or diluted to 20% in water). The RSDL-lotion was superior in reducing the penetration of VX through human skin, both when exposed as neat agent and when diluted to 20% in water. Swabbing with the RSDL-sponge during 2 min revealed decreased efficacy compared to applying the RSDL-lotion directly on the skin for 30 min. Decontamination with Fuller's Earth and alldecontMED significantly reduced the penetration of neat concentration of VX through human skin. PS104-powder was insufficient for decontamination of VX at both time-points, independently of the skin contact time of PS104. The PS104-slurry (a mixture of PS104-powder and water), slightly improved the decontamination efficacy. Comparing the time-points for initiated decontamination revealed less penetrated VX for RSDL and Fuller's Earth when decontamination was initiated after 5 min compared to 30 min post-exposure, while alldecontMED displayed similar efficacy at both time-points. Decontamination by washing with water only resulted in a significant reduction of penetrated VX when washing was performed 5 min after exposure, but not when decontamination was delayed to 30 min post-exposure of neat VX. In conclusion, early initiated decontamination with the
International Nuclear Information System (INIS)
Caldwell, J.T.; Bieri, J.M.; Hastings, R.D.; Horton, W.S.; Kuckertz, T.H.; Kunz, W.E.; Plettenberg, K.; Smith, L.D.
1990-01-01
The goal of a safe, efficient and economic decontamination and decommissioning of plutonium facilities can be greatly enhanced through the intelligent use of an integrated system of nondestructive assay equipment. We have designed and fabricated such a system utilizing five separate NDA stations integrated through a single data acquisition and management personal computer-based controller. The initial station utilizes a passive neutron measurement to determine item Pu inventory to the 0.1 gm level prior to insertion into the decontamination cell. A large active neutron station integrated into the cell is used to measure decontamination effectiveness at the 10 nci/gm level. Cell Pu buildup at critical points is monitored with passive neutron detectors. An active neutron station having better than 1 mg Pu assay sensitivity is used to quantify final compacted waste pucks outside the cell. Bulk Pu in various forms and isotopic enrichments is quantified in a combined passive neutron coincidence and high resolution gamma ray spectrometer station outside the cell. Item control and Pu inventory are managed with bar code labeling and a station integrating algorithm. Overall economy is achieved by multiple station use of the same expensive hardware such as the neutron generator
Laser Decontamination of Surfaces Contaminated with Cs+ Ion
International Nuclear Information System (INIS)
Baigalmaaa, B.; Won, H. J.; Moon, J. K.; Jung, C. H.; Lee, K. W.; Hyun, J. H.
2008-01-01
Laser decontamination technology has been proven to be an efficient method for a surface modification of metals and concretes contaminated with radioactive isotopes. Furthermore, the generation of a secondary waste is negligible. The radioactivity of hot cells in the DFDF (Dupic Fuel Development Facility) is presumed to be very high and the predominant radionuclide is Cs-137. A series of laser decontamination studies by a fabricated Q-switched Nd:YAG laser system were performed on stainless steel specimens artificially contaminated with Cs+ ion. Decontamination characteristics of the stainless steel were analyzed by SEM and EPMA
Decontamination Systems Information and Research Program
International Nuclear Information System (INIS)
Berg, M.; Sack, W.A.; Gabr, M.
1994-01-01
The Decontamination Systems Information and Research Program at West Virginia University consists of research and development associated with hazardous waste remediation problems at the Department of Energy complex and elsewhere. This program seeks to facilitate expedited development and implementation of solutions to the nation's hazardous waste clean-up efforts. By a unique combination of university research and private technology development efforts, new paths toward implementing technology and speeding clean-ups are achievable. Mechanisms include aggressive industrial tie-ins to academic development programs, expedited support of small business technology development efforts, enhanced linkages to existing DOE programs, and facilitated access to hazardous waste sites. The program topically falls into an information component, which includes knowledge acquisition, technology evaluation and outreach activities and an R and D component, which develops and implements new and improved technologies. Projects began in February 1993 due to initiation of a Cooperative Agreement between West Virginia University and the Department of Energy
Report on practical use of new decontamination technology
International Nuclear Information System (INIS)
Nitta, Hideyuki; Ono, Masahiro
2000-03-01
For removing surface contamination of a solid waste with radioactivity, technology of laser cleaning and vacuum arc cleaning has the possibility to obtain the high decontamination rate. We made a research for practical uses of these methods as a new cleaning technology from published papers and patents. From these results, we discussed about an applicability of laser cleaning and vacuum arc cleaning to decontaminate a body of centrifugal separator. At first, we investigate the solid surface cleaning technology with a laser or a vacuum arc from published papers in the world and the patents in Japan. The results were listed in tables. Each information was abstracted into a technical data sheet and sorted into a related technology (system or equipment). We also investigate the decontamination technology by the same way and the results were abstracted into technical data sheets and sorted into related technologies, too. As an application of the above research, we considered the process and the system for decontaminating a body of centrifugal separators (cylinders). In the system, the cleaning head is set inside the cylinder and the inner surface contaminated by radioactivity is removed by the irradiation of a YAG laser, a CO2 laser or a vacuum arc. The cylinder is rotated by rotational rings and moved towards the direction of the central axis and the whole inner surface of the cylinder is cleaned with a constant cleaning rate. We also estimated the costs of each decontamination technology. (author)
Modification of the Decontamination Facility at the Kruemmel NPP - 13451
International Nuclear Information System (INIS)
Klute, Stefan; Kupke, Peter
2013-01-01
walls are welded gap-free and all rough edges are rounded off. All wetted parts are steel grade 1.4301 or higher. In an extension to the high pressure water decontamination box, 2 ultrasonic ponds and one washing station for small components as provide by new construction. A long pond with 3.25 m length for the decontamination of large components (e.g. turbine blades, pump rotors, driving rods) was installed. For the handling heavy components, a 2 t crane was installed. New construction of a mechanical effluent treatment facility including oil separator was connected to the existing effluent storage tank provided by the customer. One exhaust air filtration system is provided for each decontamination box, with the following requirements. The exhaust air is sent back to the room (recirculated air system). Dry blasting box including raw separator with dust collection in 200 l drum, filter for suspended particles; High pressure water decontamination box and wet area with water separator, pre-separator, filter for suspended particles. Installation of a steel platform at building height +12.85 above the decontamination boxes + 8.50 m for the erection of the high pressure water facilities, the recirculating air filter system, the air compressor and the respiratory air supply unit. The aforementioned components are placed on the steel platform and have been encased in a sound-lowering and accessible manner. New construction of the entire E and C technology for the TU system including modification of the supply lines from the switch gear. All devices are to be operated automatically. Dry blasting box, high pressure water decontamination box and wet area are designed to guarantee a unitary 'exterior view' of the decontamination facility. (authors)
Modification of the Decontamination Facility at the Kruemmel NPP - 13451
Energy Technology Data Exchange (ETDEWEB)
Klute, Stefan; Kupke, Peter [Siempelkamp Nukleartechnik GmbH Am Taubenfeld 25/1, 69123 Heidelberg (Germany)
2013-07-01
walls are welded gap-free and all rough edges are rounded off. All wetted parts are steel grade 1.4301 or higher. In an extension to the high pressure water decontamination box, 2 ultrasonic ponds and one washing station for small components as provide by new construction. A long pond with 3.25 m length for the decontamination of large components (e.g. turbine blades, pump rotors, driving rods) was installed. For the handling heavy components, a 2 t crane was installed. New construction of a mechanical effluent treatment facility including oil separator was connected to the existing effluent storage tank provided by the customer. One exhaust air filtration system is provided for each decontamination box, with the following requirements. The exhaust air is sent back to the room (recirculated air system). Dry blasting box including raw separator with dust collection in 200 l drum, filter for suspended particles; High pressure water decontamination box and wet area with water separator, pre-separator, filter for suspended particles. Installation of a steel platform at building height +12.85 above the decontamination boxes + 8.50 m for the erection of the high pressure water facilities, the recirculating air filter system, the air compressor and the respiratory air supply unit. The aforementioned components are placed on the steel platform and have been encased in a sound-lowering and accessible manner. New construction of the entire E and C technology for the TU system including modification of the supply lines from the switch gear. All devices are to be operated automatically. Dry blasting box, high pressure water decontamination box and wet area are designed to guarantee a unitary 'exterior view' of the decontamination facility. (authors)
Decontamination effectiveness of mixtures of citric acid, oxalic acid and EDTA
International Nuclear Information System (INIS)
Speranzini, R.A.
1990-01-01
An experimental study of the decontamination effectiveness of citric acid, oxalic acid and EDTA mixtures was conducted to assess whether oxalic acid could be removed from decontamination solutions to minimize corrosion. In loop experiments, radioactive specimens from two boiling water reactors and one pressurized water reactor were suspended in solutions of single acids or in mixtures of reagents at total reagent concentrations of less than 0.1 wt% under conditions similar to those used to decontaminate reactor systems. Rate constants for dissolution of oxides and decontamination factors were measured. Based on the results, it was concluded that under certain conditions, oxalic acid was the most effective reagent for the dissolution of oxides. It was also found, however, that conditions under which effective dissolution occurred in solutions of oxalic acid and/or citric acid were difficult to define and control. EDTA was found to be an effective reagent for dissolution of oxides such that rates of dissolution in EDTA containing solutions at 117 degrees Celsius were comparable to rates in oxalic acid containing solutions. At 90 degrees Celsius, EDTA acted synergistically with oxalic acid such that the rate of dissolution of oxides in citric-acid/oxalic-acid/EDTA solutions was higher than in citric-acid/EDTA solutions. The rates of dissolution of oxides were significantly reduced when 60 mg/kg of ferric ion was added to the citric-acid/oxalic-acid, citric-acid/EDTA and citric-acid/oxalic-acid/EDTA solutions. It was concluded that effective decontaminations of BWR and PWR systems could be achieved with mixtures of citric acid and EDTA
Decontamination of radioisotope production facility
International Nuclear Information System (INIS)
Daryoko, M.; Yatim, S.; Suseno, H.; Wiratmo, M.
1998-01-01
The strippable coating method use phosphoric glycerol and irradiated latex as supporting agents have been investigated. The investigation used some decontaminating agents: EDTA, citric acid, oxalic acid and potassium permanganate were combined with phosphoric glycerol supporting agent, then EDTA Na 2 , sodium citric, sodium oxalic and potassium permanganate were combined with irradiated latex supporting agent. The study was needed to obtain the representative operating data, will be implemented to decontamination the Hot Cell for radioisotope production. The experiment used 50x50x1 mm stainless steel samples and contaminated by Cs-137 about 1.1x10 -3 μCi/cm 2 . This samples according to inner cover of Hot Cell material, and Hot Cell activities. The decontamination factor results of the investigation were: phosphoric glycerol as supporting agent, about 20 (EDTA as decontaminating agent) to 47 (oxalic acid as decontaminating agent), and irradiated latex as supporting agent, about 11.5 (without decontamination agent) to 27 (KMnO 4 as decontaminating agent). All composition of the investigation have been obtained the good results, and can be implemented for decontamination of Hot Cell for radioisotope production. The irradiated latex could be recommended as supporting agent without decontaminating agent, because it is very easy to operate and very cheap cost. (author)
Decontamination of TRU glove boxes
International Nuclear Information System (INIS)
Crawford, J.H.
1978-03-01
Two glove boxes that had been used for work with transuranic nuclides (TRU) for about 12 years were decontaminated in a test program to collect data for developing a decontamination facility for large equipment highly contaminated with alpha emitters. A simple chemical technique consisting of a cycle of water flushes and alkaline permanganate and oxalic acid washes was used for both boxes. The test showed that glove boxes and similar equipment that are grossly contaminated with transuranic nuclides can be decontaminated to the current DIE nonretrievable disposal guide of <10 nCi TRU/g with a moderate amount of decontamination solution and manpower. Decontamination of the first box from an estimated 1.3 Ci to about 5 mCi (6 nCi/g) required 1.3 gallons of decontamination solution and 0.03 man-hour of work for each square foot of surface area. The second box was decontaminated from an estimated 3.4 Ci to about 2.8 mCi (4.2 nCi/g) using 0.9 gallon of decontamination solution and 0.02 man-hour for each square foot of surface area. Further reductions in contamination were achieved by repetitive decontamination cycles, but the effectiveness of the technique decreased sharply after the initial cycle
Excessively High Vapor Pressure of Al-based Amorphous Alloys
Directory of Open Access Journals (Sweden)
Jae Im Jeong
2015-10-01
Full Text Available Aluminum-based amorphous alloys exhibited an abnormally high vapor pressure at their approximate glass transition temperatures. The vapor pressure was confirmed by the formation of Al nanocrystallites from condensation, which was attributed to weight loss of the amorphous alloys. The amount of weight loss varied with the amorphous alloy compositions and was inversely proportional to their glass-forming ability. The vapor pressure of the amorphous alloys around 573 K was close to the vapor pressure of crystalline Al near its melting temperature, 873 K. Our results strongly suggest the possibility of fabricating nanocrystallites or thin films by evaporation at low temperatures.
Modeling of low temperature plasma for surface and Airborne decontamination
Mihailova, D.; van Dijk, J.; Hagelaar, G.; Belenguer, P.; Guillot, P.
2014-01-01
This paper aims to study and develop new plasma-based technology for the next generation of molecular decontamination systems. A capacitively coupled plasma is considered for cleaning using the plasma fluxes directed to the walls. The model used for this purpose is the PLASIMO fluid module applied
Dry Ice Blast Decontamination to in-service equipment in Japanese PWR plant
International Nuclear Information System (INIS)
2016-01-01
MHI had developed several mechanical decontamination methods. Mechanical decontamination is beneficial when it is applied to equipment whose surface is narrow. Especially in terms of secondary waste reduction, MHI started the study of application of Dry Ice Blast Decontamination to actual PWR plant. This paper provides an introduction to Dry Ice Blast Decontamination principle, its system and actual application result to PWR plant. (J.P.N.)
Energy Technology Data Exchange (ETDEWEB)
Yin, Yanmin; Qiu, Jianhua; Yang, Limin [College of Chemistry and Chemical Engineering, Xiamen University, Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, Xiamen (China); Wang, Qiuquan [College of Chemistry and Chemical Engineering, Xiamen University, Department of Chemistry and the MOE Key Laboratory of Analytical Sciences, Xiamen (China); Xiamen University, State Key Laboratory of Marine Environmental Science, Xiamen (China)
2007-06-15
A new vapor generation system for mercury (Hg) species based on the irradiation of mercaptoethanol (ME) with UV was developed to provide an effective sample introduction unit for atomic fluorescence spectrometry (AFS). Preliminary investigations of the mechanism of this novel vapor generation system were based on GC-MS and FT-IR studies. Under optimum conditions, the limits of determination for inorganic divalence mercury and methyl mercury were 60 and 50 pg mL{sup -1}, respectively. Certified reference materials (BCR 463 tuna fish and BCR 580 estuarine sediment) were used to validate this new method, and the results agreed well with certified values. This new system provides an attractive alternative method of chemical vapor generation (CVG) of mercury species compared to other developed CVG systems (for example, the traditional KBH{sub 4}/NaOH-acid system). To our knowledge, this is the first systematic report on UV/ME-based Hg species vapor generation and the determination of total and methyl Hg in environmental and biological samples using UV/ME-AFS. (orig.)
Meyer, K M; Calfee, M W; Wood, J P; Mickelsen, L; Attwood, B; Clayton, M; Touati, A; Delafield, R
2014-03-01
To evaluate hydrogen peroxide vapour (H2 O2 ) for its ability to inactivate Bacillus spores within a laboratory-scale heating, ventilation and air-conditioning (HVAC) duct system. Experiments were conducted in a closed-loop duct system, constructed of either internally lined or unlined galvanized metal. Bacterial spores were aerosol-deposited onto 18-mm-diameter test material coupons and strategically placed at several locations within the duct environment. Various concentrations of H2 O2 and exposure times were evaluated to determine the sporicidal efficacy and minimum exposure needed for decontamination. For the unlined duct, high variability was observed in the recovery of spores between sample locations, likely due to complex, unpredictable flow patterns within the ducts. In comparison, the lined duct exhibited a significant desorption of the H2 O2 following the fumigant dwell period and thus resulted in complete decontamination at all sampling locations. These findings suggest that decontamination of Bacillus spore-contaminated unlined HVAC ducts by hydrogen peroxide fumigation may require more stringent conditions (higher concentrations, longer dwell duration) than internally insulated ductwork. These data may help emergency responders when developing remediation plans during building decontamination. © 2013 The Society for Applied Microbiology This article has been contributed to by US Government employees and their work is in the public domain in the USA.
Vapor and gas sampling of single-shell tank 241-U-104 using the in situ vapor sampling system
International Nuclear Information System (INIS)
Lockrem, L.L.
1997-01-01
The Vapor Issue.Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-U-104. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the July 16, 1996 sampling of SST 241-U-104. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media
Vapor and gas sampling of single-shell tank 241-S-103 using the in situ vapor sampling system
International Nuclear Information System (INIS)
Lockrem, L.L.
1997-01-01
The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-103. This document presents In Situ Vapor Sampling System (ISVS) data resulting from the June 12, 1996 sampling of SST 241-S-103. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which supplied and analyzed the sample media
Vapor and gas sampling of single-shell tank 241-S-106 using the in situ vapor sampling system
International Nuclear Information System (INIS)
Lockrem, L.L.
1997-01-01
The Vapor Issue Resolution Program tasked the Vapor Team (VT) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-S-106. This document presents In Situ vapor Sampling System (ISVS) data resulting from the June 13, 1996 sampling of SST 241-S-106. Analytical results will be presented in separate reports issued by the Pacific Northwest National Laboratory (PNNL) which'supplied and analyzed the sample media
2018-03-16
and Decontamination Considerations Brandy J. White Martin H. Moore Brian J. Melde Laboratory for the Study of Molecular Interfacial Interactions...Decontamination Considerations Brandy J. White, Martin H. Moore, Brian J. Melde, Anthony P. Malanoksi, and Chanté Campbell1 Center for Bio/Molecular
Effect of decontamination on nuclear power plant primary circuit materials
International Nuclear Information System (INIS)
Brezina, M.; Kupca, L.
1991-01-01
The effect of repeated decontamination on the properties of structural materials of the WWER-440 primary coolant circuit was examined. Three kinds of specimens of 08Kh18Ni10T steel were used for radioactivity-free laboratory experiments; they included material obtained from assembly additions to the V-2 nuclear power plant primary piping, and a sheet of the CSN 17247 steel. Various chemical, electrochemical and semi-dry electrochemical decontamination procedures were tested. Chemical decontamination was based on the conventional AP(20/5)-CITROX(20/20) procedure and its variants; NP-CITROX type procedures with various compositions were also employed. Solutions based on oxalic acid were tested for the electrochemical and semi-dry electrochemical decontamination. The results of measurements of mass losses of the surfaces, of changes in the corrosion resistance and in the mechanical properties of the materials due to repeated decontamination are summarized. (Z.S.). 12 figs., 1 tab., 8 refs
Overview of nonchemical decontamination techniques
International Nuclear Information System (INIS)
Allen, R.P.
1984-09-01
The decontamination techniques summarized in this paper represent a variety of surface cleaning methods developed or adapted for component and facility-type decontamination applications ranging from small hand tools to reactor cavities and other large surface areas. The major conclusion is that decontamination is a complex, demanding technical discipline. It requires knowledgeable, experienced and well-trained personnel to select proper techniques and combinations of techniques for the varied plant applications and to realize their full performance potential. Unfortunately, decontamination in many plants has the lowest priority of almost any activity. Operators are unskilled and turnover is so frequent that expensive decontamination capabilities remain unused while decontamination operations revert to the most rudimentary type of hand scrubbing and water spray cleaning
High temperature thermodynamics and vaporization of the zirconium--niobium--oxygen system
International Nuclear Information System (INIS)
Rinehart, G.H.
1978-01-01
The vaporization behavior of the Zr--Nb--O system was studied by means of successive vaporization, Knudsen effusion-target collection experiments, and mass spectrometric analysis of the vapors effusing from a Knudsen crucible. The successive vaporization experiments were performed on two ternary samples in open crucibles. X-ray powder diffraction patterns of the residues and x-ray fluorescence analysis of the condensates and residues indicated the preferential vaporization of niobium-containing species with the composition of the residue subsequently becoming closer to that of congruently vaporizing ZrO/sub 2-x/. The Knudsen effusion-target collection experiments were employed on two samples, pure NbO 2 (s) and a two-phase ZrO 2 --NbO 2 mixture, in order to obtain information on the activity of NbO 2 in the two-phase mixture. Second law enthalpies and entropies of sublimation as well as third law enthalpies were obtained for both systems. The vaporization behaviors of five compositions in the Zr--Nb--O system, NbO 2 , NbO, a ZrO 2 --NbO 2 two-phase mixture, Nb 2 O 5 , and Zr 6 Nb 2 O 17 , were investigated. Above Nb 2 O 5 and the fully oxidized Zr 6 Nb 2 O 17 oxygen is preferentially lost; over NbO 2 , the two-phase ZrO 2 --NbO 2 system, and NbO the principal gaseous species is NbO 2
Ioanid, E. G.; Dunca, S.; Rusu, D.; Tǎnase, C.
2012-04-01
Documents decontamination using dry methods, less invasive than the wet ones implying toxic nocuous substances for cellulose-based materials, has been the object of numerous studies. In recent years mixed researchers teams have been studying the possibility of one-step document decontamination performed by a dry treatment, the risks of repeated wet manipulation thus being reduced. Among physical methods appropriate to this end, high-frequency cold plasma and corona effect can be mentioned. Our studies were carried out on samples taken from ancient books with no cultural heritage value. The decontamination efficiency and the impact on paper of the two types of treatments were determined by: microbiological analysis, scanning electron microscopy, FTIR, chromatic alterations and gloss determination. The above-mentioned procedures eliminate the use of chemical conservation substances, nocuous for the paper support. At the same time the health risk for conservators, restorers, archivists or archive's users is removed.
Method for decontaminating radiation metal waste
International Nuclear Information System (INIS)
Onuma, Tsutomu; Tanaka, Akio; Akimoto, Hidetoshi
1991-01-01
This report describes a method for decontaminating radiation metal waste characterized by the following properties: in order to decontaminate radiation metal waste of various shapes produced by facilities involved with radioactive substances, non-complex shapes are decontaminated by electropolishing the materials in a neutral saline solution. Complex shapes are chemically decontaminated by means of an acid solution containing permanganic acid or an alkaline solution and a mineral acid solution. After neutralizing the solutions used for chemical decontamination, the radioactive material is separated and removed. Further, in the decontamination method for radioactive metal waste, a supernatant liquid is reused as the electrolyte in electropolishing decontamination. Permanganic ions (MnO 4 - ) are reduced to manganese dioxide (MnO 2 ) and deposited prior to neutralizing the solution used for chemical decontamination. Once manganese dioxide (MnO 2 ) has been separated and removed, it is re-used as the electrolyte in electropolishing decontamination by means of a process identical to the separation process for radioactive substances. 3 figs
Los Alamos DP West Plutonium Facility decontamination project, 1978-1981
International Nuclear Information System (INIS)
Garde, R.; Cox, E.J.; Valentine, A.M.
1982-09-01
The DP West Plutonium Facility operated by the Los Alamos National Laboratory, Los Alamos, New Mexico was decontaminated between April 1978 and April 1981. The facility was constructed in 1944 to 1945 to produce plutonium metal and fabricate parts for nuclear weapons. It was continually used as a plutonium processing and research facility until mid-1978. Decontamination operations included dismantling and removing gloveboxes and conveyor tunnels; removing process systems, utilities, and exhaust ducts; and decontaminating all remaining surfaces. This report describes glovebox and conveyor tunnel separations, decontamination techniques, health and safety considerations, waste management procedures, and costs of the operation
Results of chemical decontamination of DOE`s uranium-enrichment scrap metal
Energy Technology Data Exchange (ETDEWEB)
Levesque, R.G.
1997-02-01
The CORPEX{reg_sign} Nuclear Decontamination Processes were used to decontaminate representative scrap metal specimens obtained from the existing scrap metal piles located at the Department of Energy (DOE) Portsmouth Gaseous Diffusion Plant (PORTS), Piketon, Ohio. In September 1995, under contract to Lockheed Martin Energy Systems, MELE Associates, Inc. performed the on-site decontamination demonstration. The decontamination demonstration proved that significant amounts of the existing DOE scrap metal can be decontaminated to levels where the scrap metal could be economically released by DOE for beneficial reuse. This simple and environmentally friendly process can be used as an alternative, or in addition to, smelting radiologically contaminated scrap metal.
Urban Decontamination Experience at Pripyat Ukraine - 13526
Energy Technology Data Exchange (ETDEWEB)
Paskevych, Sergiy [Institute for Safety Problems of Nuclear Power Plants, National Academy of Sciences of Ukraine, 36 a Kirova str. Chornobyl, Kiev region, 07200 (Ukraine); Voropay, Dmitry [Federal State Unitary Enterprise ' Russian State Center of Inventory and Registration and Real Estate - Federal Bureau of Technical Inventory' , 37-2 Bernadsky Prospekt, Moscow Russia 119415 (Russian Federation); Schmieman, Eric [Battelle Memorial Institute, PO Box 999 MSIN K6-90, Richland, WA 99352 (United States)
2013-07-01
This paper describes the efficiency of radioactive decontamination activities of the urban landscape in the town of Pripyat, Ukraine. Different methods of treatment for various urban infrastructure and different radioactive contaminants are assessed. Long term changes in the radiation condition of decontaminated urban landscapes are evaluated: 1. Decontamination of the urban system requires the simultaneous application of multiple methods including mechanical, chemical, and biological. 2. If a large area has been contaminated, decontamination of local areas of a temporary nature. Over time, there is a repeated contamination of these sites due to wind transport from neighboring areas. 3. Involvement of earth-moving equipment and removal of top soil by industrial method achieves 20-fold reduction in the level of contamination by radioactive substances, but it leads to large amounts of waste (up to 1500 tons per hectare), and leads to the re-contamination of treated areas due to scatter when loading, transport pollutants on the wheels of vehicles, etc.. (authors)
Verification of wet blasting decontamination technology
International Nuclear Information System (INIS)
Matsubara, Sachito; Murayama, Kazunari; Yoshida, Hirohisa; Igei, Shigemitsu; Izumida, Tatsuo
2013-01-01
Macoho Co., Ltd. participated in the projects of 'Decontamination Verification Test FY 2011 by the Ministry of the Environment' and 'Decontamination Verification Test FY 2011 by the Cabinet Office.' And we tested verification to use a wet blasting technology for decontamination of rubble and roads contaminated by the accident of Fukushima Daiichi Nuclear Power Plant of the Tokyo Electric Power Company. As a results of the verification test, the wet blasting decontamination technology showed that a decontamination rate became 60-80% for concrete paving, interlocking, dense-grated asphalt pavement when applied to the decontamination of the road. When it was applied to rubble decontamination, a decontamination rate was 50-60% for gravel and approximately 90% for concrete and wood. It was thought that Cs-134 and Cs-137 attached to the fine sludge scraped off from a decontamination object and the sludge was found to be separated from abrasives by wet cyclene classification: the activity concentration of the abrasives is 1/30 or less than the sludge. The result shows that the abrasives can be reused without problems when the wet blasting decontamination technology is used. (author)
New decontamination technologies for environmental applications
International Nuclear Information System (INIS)
Allen, R.P.; Arrowsmith, H.W.; McCoy, M.W.
1981-01-01
The technologies discussed represent a versatile collection of tools and approaches for environmental decontamination applications. The fixatives provide a means for gaining and maintaining control of large contaminated areas, for decontaminating large surface areas, and for protecting equipment and supplies used in decontamination operations. The other decontamination techniques together provide a method for removing loose surface contamination from almost all classes of materials and surfaces. These techniques should have wide application both as direct decontamination processes and for the cleaning of tools and equipment used in the decontamination operations
Energy Technology Data Exchange (ETDEWEB)
Trovato, S.A.; Parry, J.O. [Consolidated Edison Co., New York, NY (United States)
1995-03-01
Key to the safe and efficient operation of the nation`s civilian nuclear power plants is the performance of maintenance activities within regulations and guidelines for personnel radiation exposure. However, maintenance activities, often performed in areas of relatively high radiation fields, will increase as the nation`s plant age. With the Nuclear Regulatory Commission (NRC) lowering the allowable radiation exposure to plant workers in 1994 and considering further reductions and regulations in the future, it is imperative that new techniques be developed and applied to reduce personnel exposure. Full primary system chemical decontamination technology offers the potential to be single most effective method of maintaining workers exposure {open_quotes}as low as reasonably achievable{close_quotes} (ALARA) while greatly reducing plant operation and maintenance (O&M) costs. A three-phase program underway since 1987, has as its goal to demonstrate that full RCS decontamination is a visible technology to reduce general plant radiation levels without threatening the long term reliability and operability of a plant. This paper discusses research leading to and plans for a National Demonstration of Full RCS Chemical Decontamination at Indian Point 2 nuclear generating station in 1995.
Non-destructive decontamination of building materials
Holecek, Josef; Otahal, Petr
2015-11-01
For nondestructive radiation decontamination of surfaces it is necessary to use varnishes, such as ARGONNE, DG1101, DG1108, etc. This text evaluates the use of manufactured strippable coatings for radiation decontamination. To evaluate decontamination capability of such coatings the following varnishes were selected and subsequently used: AZ 1-700 and AXAL 1807S. The varnishes were tested on different building materials surfaces contaminated by short-term radioisotopes of Na-24 or La-140, in water soluble or water insoluble forms. Decontamination quality was assessed by the decontamination efficiency value, defined as the proportion of removed activity to the applied activity. It was found that decontamination efficiency of both used varnishes depends not only on the form of contaminant, but in the case of application of AXAL 1807S varnish it also depends on the method of its application on the contaminated surface. The values of the decontamination efficiency for AZ1-700 varnish range from 46% for decontamination of a soluble form of the radioisotope from concrete surface to 98% for the decontamination of a soluble form of the radioisotope from ceramic tile surface. The decontamination efficiency values determined for AXAL 1807S varnish range from 48% for decontamination of a soluble form of the radioisotope from concrete surface to 96% for decontamination of an insoluble form of the radioisotope from ceramic tile surface. Comparing these values to the values given for the decontaminating varnishes we can conclude that AXAL 1807S varnish is possible to use on all materials, except highly porous materials, such as plasterboard or breeze blocks, or plastic materials. AZ 1-700 varnish can be used for all dry materials except plasterboard.
Alpha Decontamination and Disassembly Pilot Facility. Final report
International Nuclear Information System (INIS)
Daugherty, B.A.; Clark, H.E.
1985-04-01
The Alpha Decontamination and Disassembly (AD and D) Pilot Facility was built to develop and demonstrate a reference process for the decontamination and size reduction of noncombustible transuranic (TRU) waste. The goals of the reference process were to remove >99% of the surface contamination to the high-level waste tanks, and to achieve volume reduction factors greater than 15:1. Preliminary bench-scale decontamination work was accomplished at Savannah River Laboratory (SRL), establishing a reference decontamination process. Initially, the pilot facility did not achieve the decontamination goals. As the program continued, and modifications to the process were made, coupon analysis idicated that 99% of the surface contamination was removed to the high-level drain system. Prior to the AD and D Pilot Facility, no size reduction work had been done at SRL. Several other Department of Energy (DOE) facilities were experimenting with plasma arc torches for size reduction work. Their methods were employed in the AD and D hot cell with moderate success. The experimental work concluded with recommendations for further testing of other size reduction techniques. 11 figs., 6 tabs
Final report on the decontamination of the Curium Source Fabrication Facility
International Nuclear Information System (INIS)
Schaich, R.W.
1983-12-01
The Curium Source Fabrication Facility (CSFF) at Oak Ridge National Laboratory (ORNL) was decontaminated to acceptable contamination levels for maintenance activities, using standard decontamination techniques. Solid and liquid waste volumes were controlled to minimize discharges to the ORNL waste systems. This program required two years of decontamination effort at a total cost of approximately $700K. 5 references, 7 figures, 2 tables
Vapor and gas sampling of single-shell tank 241-B-102 using the in situ vapor sampling system
International Nuclear Information System (INIS)
Lockrem, L.L.
1997-01-01
The Vapor Issue Resolution Program tasked the Vapor Team (the team) to collect representative headspace samples from Hanford Site single-shell tank (SST) 241-B-102. This document presents sampling data resulting from the April 18, 1996 sampling of SST 241-B-102. Analytical results will be presented in a separate report issued by Pacific Northwest National Laboratory (PNNL), which supplied and analyzed the sampling media. The team, consisting of Sampling and Mobile Laboratories (SML) and Special Analytical Studies (SAS) personnel, used the vapor sampling system (VSS) to collect representative samples of the air, gases, and vapors from the headspace of SST 241-B-102 with sorbent traps and SUMMA canisters
International Nuclear Information System (INIS)
Senol, Aynur
2015-01-01
Highlights: • A new polynomial vapor pressure approach for pure solvents is presented. • Solvation models reproduce the vapor pressure data within a 4% mean error. • A concentration-basis vapor pressure model is also implemented on relevant systems. • The reliability of existing models was analyzed using log-ratio objective function. - Abstract: A new polynomial vapor pressure approach for pure solvents is presented. The model is incorporated into the LSER (linear solvation energy relation) based solvation model framework and checked for consistency in reproducing experimental vapor pressures of salt-containing solvent systems. The developed two structural forms of the generalized solvation model (Senol, 2013) provide a relatively accurate description of the salting effect on vapor pressure of (solvent + salt) systems. The equilibrium data spanning vapor pressures of eighteen (solvent + salt) and three (solvent (1) + solvent (2) + salt) systems have been subjected to establish the basis for the model reliability analysis using a log-ratio objective function. The examined vapor pressure relations reproduce the observed performance relatively accurately, yielding the overall design factors of 1.084, 1.091 and 1.052 for the integrated property-basis solvation model (USMIP), reduced property-basis solvation model and concentration-dependent model, respectively. Both the integrated property-basis and reduced property-basis solvation models were able to simulate satisfactorily the vapor pressure data of a binary solvent mixture involving a salt, yielding an overall mean error of 5.2%
Decontamination processes for waste glass canisters
International Nuclear Information System (INIS)
Rankin, W.N.
1981-06-01
The process which will be used to decontaminate waste glass canisters at the Savannah River Plant consists of: decontamination (slurry blasting); rinse (high-pressure water); and spot decontamination (high-pressure water plus slurry). No additional waste will be produced by this process because glass frit used in decontamination will be mixed with the radioactive waste and fed into the glass melter. Decontamination of waste glass canisters with chemical and abrasive blasting techniques was investigated. The ability of a chemical technique with HNO 3 -HF and H 2 C 2 O 4 to remove baked-on contamination was demonstrated. A correlation between oxide removal and decontamination was observed. Oxide removal and, thus, decontamination by abrasive blasting techniques with glass frit as the abrasive was proposed and demonstrated
Decontamination processes for waste glass canisters
International Nuclear Information System (INIS)
Rankin, W.N.
1981-01-01
The process which will be used to decontaminate waste glass canisters at the Savannah River Plant consists of: decontamination (slurry blasting); rinse (high-pressure water); and spot decontamination (high-pressure water plus slurry). No additional waste will be produced by this process because glass frit used in decontamination will be mixed with the radioactive waste and fed into the glass melter. Decontamination of waste glass canisters with chemical and abrasive blasting techniques was investigated. The ability of a chemical technique with HNO 3 -HF and H 2 C 2 O 4 to remove baked-on contamination was demonstrated. A correlation between oxide removal and decontamination was observed. Oxide removal and, thus, decontamination by abrasive blasting techniques with glass frit as the abrasive was proposed and demonstrated
Reactor component chemical decontamination-developments in waste handling and disposal
International Nuclear Information System (INIS)
Papesch, R.; Atwood, K.L.
1989-01-01
Because of restrictive limits on man-rem exposure in European nuclear plants, a company has developed and applied a number of chemical decontamination techniques for components that must be periodically maintained. These techniques are particularly effective for components that can be placed in a decontamination bath for dose reduction prior to performing maintenance. The cleaning technique has the ability to achieve decontamination factors of at least 20 and in some cases much greater. For components with before cleaning dose rates of between 1 to as high as 80 R/hr, significant man-rem reductions are achieved when hundreds of manhours may be required to complete required component maintenance. Transferring this solvent technology to the U.S. required a program to develop solidification formulas to allow the solvent wastes to be disposed of in accordance with regulations and in a cost effective manner. This paper demonstrates in chemical decontaminations with small liquid volume systems that concentrated decontamination solvents can be employed to achieve high decontamination factors
International Nuclear Information System (INIS)
Mestre, E.; Sautiez, N.
1957-10-01
With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)
Corrosion surveillance of the chemical decontamination process in Kuosheng nuclear power plant
International Nuclear Information System (INIS)
Wang, L.H.
2002-01-01
The Piping Recirculation System (RRS) and reactor water clean-up system (RWCU) of Kuosheng Nuclear Power Plant of Taiwan Power Company were decontaminated by CORD process of Framatome ANP GmbH during the outage at October 2001. This is the first time that CORD process was adopted and applied in Taiwan Nuclear Power Plant. To verify minor corrosion damage and correct process control, the material corrosion condition was monitored during all the stages of the chemical decontamination work. Three kinds of specimen were adopted in this corrosion monitoring, including corrosion coupons for weight loss measurements, electrochemical specimens for on-line corrosion monitoring, and WOL specimens (wedge opening loaded) for stress corrosion evaluation. The measured metal losses from nine coupon materials did not reveal any unexpected or intolerable high corrosion damage from the CORD UV or CORD CS processes. The coupon materials included type 304 stainless steel (SS) with sensitized and as-received thermal history, type 308 weld filler, type CF8 cast SS, nickel base alloy 182 weld filler, Inconel 600, Stellite 6 hard facing alloy, NOREM low cobalt hard facing alloy, and A106B carbon steel (CS). The electrochemical noise (ECN) measurements from three-electrode electrochemical probe precisely depicted the metal corrosion variation with the decontamination process change. Most interestingly, the estimated trend of accumulated metal loss is perfectly corresponding to the total removed activities. The ECN measurements were also used for examining the effect of different SS oxide films pre-formed in NWC and HWC on the decontamination efficiency, and for evaluating the galvanic effect of CS with SS. The existing cracks did not propagate further during the decontamination. The average decontamination factors achieved were 50.8 and 4.2 respectively for RRS and RWCU. (authors)
Laboratory testing of the in-well vapor-stripping system
International Nuclear Information System (INIS)
Gilmore, T.J.; Francois, O.
1996-03-01
The Volatile organic Compounds-Arid Integrated Demonstration (VOC-Arid ID) was implemented by the US Department of Energy's (DOE's) Office of Technology Development to develop and test new technologies for the remediation of organic chemicals in the subsurface. One of the technologies being tested under the VOC-Arid ID is the in-well vapor-stripping system. The in-well vapor-stripping concept was initially proposed by researchers at Stanford University and is currently under development through a collaboration between workers at Stanford University and DOE's Pacific Northwest National Laboratory. The project to demonstrate the in-well vapor-stripping technology is divided into three phases: (1) conceptual model and computer simulation, (2) laboratory testing, and (3) field demonstration. This report provides the methods and results of the laboratory testing in which a full-scale replica was constructed and tested above ground in a test facility located at DOE's Hanford Site, Washington. The system is a remediation technology designed to preferentially extract volatile organic compounds (VOCs) from contaminated groundwater by converting them to a vapor phase
Chemical decontaminating method for stainless steel
International Nuclear Information System (INIS)
Onuma, Tsutomu; Akimoto, Hidetoshi.
1990-01-01
Radioactive metal wastes comprising passivated stainless steels are chemically decontaminated to such a radioactivity level as that of usual wastes. The present invention for chemically decontaminating stainless steels comprises a first step of immersing decontaminates into a sulfuric acid solution and a second step of immersing them into an aqueous solution prepared by adding oxidative metal salts to sulfuric acid, in which a portion of the surface of stainless steels as decontaminates are chemically ground to partially expose substrate materials and then the above-mentioned decontamination steps are applied. More than 90% of radioactive materials are removed in this method by the dissolution of the exposed substrate materials and peeling of cruds secured to the surface of the materials upon dissolution. This method is applicable to decontamination of articles having complicate shapes, can reduce the amount of secondary wastes after decontamination and also remarkably shorten the time required for decontamination. (T.M.)
Actual situation on the field of decontamination in Slovak and Czech NPPs
International Nuclear Information System (INIS)
Prazska, M.; Rezbarik, J.; Solcanyi, M.; Trtilek, R.
2002-01-01
Many decontamination methods for various applications have proved to provide good results at Slovak and Czech nuclear power plants. A number of mechanical, chemical and electrochemical decontamination methods are available. The selection of a suitable method and decontamination technology is the result of a multicriterial optimization. The plants use the decontamination procedures described in the design documentation. New decontamination procedures aiming to minimize secondary radioactive wastes and corrosion attack on the basic material are being developed. No standardized qualification process, however, exists for such new procedures and large efforts are to be made to introduce them into practice. Methods for decommissioning purposes are based on static or dynamic application of decontamination solutions such as a mixture of formic acid + complexing agent + corrosion inhibitor or dilute HNO 3 . A process consisting in treatment in a solution containing formic acid + complexing agent + corrosion inhibitor (total concentration 3 - 4 mass %, temperature 30 - 35 deg C), whose effect is enhanced by the application of ultrasound (0.4 - 0.5 W per cm 2 decontaminated area) in a specially designed bath, is recommended for segmented metallic parts, which can be then released into the environment and recycled. Electrochemical decontamination in a bath is another efficient decontamination method to achieve unrestricted release of the material into the environment. Efficient decontamination of various highly contaminated materials can be attained by using an electrolyte solution based on citric acid (100 g.dm -3 ) + nitric acid (20 g.dm -3 ) + NH 4 NO 3 (50 g.dm -3 ) and applying a current density of 100 - 200 mA.cm -2 , electrolyte temperature 25 - 50 deg C, with one decontamination cycle period not exceeding 30 minutes. The best results are obtained by electrolysis followed by mechanical treatment using ultrasound. Electrochemical decontamination using a spraying
International Nuclear Information System (INIS)
Denisov, V.I.; Karataev, B.A.; Platonov, A.I.; Potekhin, V.B.; Ryumin, G.V.; Sorokin, N.M.; Fenogenov, V.A.; Cheremshin, P.I.
1989-01-01
The ventilation system electric motor decontamination is described. In decontaminating waterside pump rotors and stators with high level of contamination was developed a procedure, eliminating corrosion action and damage of electric isolation coatings
Decontamination of main coolant pumps
International Nuclear Information System (INIS)
Roofthooft, R.
1988-01-01
Last year a number of main coolant pumps in Belgian nuclear power plants were decontaminated. A new method has been developed to reduce the time taken for decontamination and the volume of waste to be treated. The method comprises two phases: Oxidation with permanganate in nitric acid and dissolution in oxalic acid. The decontamination of main coolant pumps can now be achieved in less than one day. The decontamination factors attained range between 15 and 150. (orig.) [de
Decontamination of radioactive clothing using microemulsion in carbon dioxide
Energy Technology Data Exchange (ETDEWEB)
Yoo, Jaeryong; Jang, Jina; Park, Kwangheon; Kim, Hongdoo; Kim, Hakwon [Kyunghee Univ., Seoul (Korea, Republic of); Yim, Sanghak; Yoon, Weonseob [Ulchin Nuclear Power Site, Ulchin (Korea, Republic of)
2006-07-01
Nuclear power is intrinsically a clean energy source due to its high energy density and low generation of waste. However, as the nuclear industry grows, a variety of radioactive wastes are increased gradually. Major subjects include contaminated components, tools, equipment, containers and facilities as well as nuclear waste such as uranium scrap and radioactive clothing. The radioactive waste can be classified by its creation. There are Trans-Uranium Nuclides (TRU), Fission Products (FP) and corrosion products. Nuclear decontamination has become an important issue in the nuclear industry. The conventional methods have some problems such as the production of secondary wastes and the use of toxic solvents. We need to develop a new method of decontamination and suggest a use of microemulsion in carbon dioxide to overcome these disadvantages. The microemulsion is the clear solution that contains the water, surfactant and carbon dioxide. The surfactant surrounded the droplet into carbon dioxide and this state is thermodynamically stable. That is, the microemulsion has a structure similar to that of a conventional water-based surfactant system. Generally, the size of droplet is about 5 {approx} 10nm. The microemulsion is able to decontaminate radioactive waste so that the polar substance is removed by water and the non-polar substance is removed by carbon dioxide. After the decontamination process, the microemulsion is separated easily to surfactant and water by decreasing the pressure under the cloud point. This way, only radioactive wastes are left in the system. Cleaned carbon dioxide is then collected and reused. Thus, there are no secondary wastes. Carbon dioxide is considered an alternative process medium. This is because it is non-toxic, non-flammable, inexpensive and easy to handle. Additionally, the tunable properties of carbon dioxide through pressure and temperature control are versatile for use in extracting organic materials. In this paper, we examine the
Decontamination of radioactive clothing using microemulsion in carbon dioxide
International Nuclear Information System (INIS)
Yoo, Jaeryong; Jang, Jina; Park, Kwangheon; Kim, Hongdoo; Kim, Hakwon; Yim, Sanghak; Yoon, Weonseob
2006-01-01
Nuclear power is intrinsically a clean energy source due to its high energy density and low generation of waste. However, as the nuclear industry grows, a variety of radioactive wastes are increased gradually. Major subjects include contaminated components, tools, equipment, containers and facilities as well as nuclear waste such as uranium scrap and radioactive clothing. The radioactive waste can be classified by its creation. There are Trans-Uranium Nuclides (TRU), Fission Products (FP) and corrosion products. Nuclear decontamination has become an important issue in the nuclear industry. The conventional methods have some problems such as the production of secondary wastes and the use of toxic solvents. We need to develop a new method of decontamination and suggest a use of microemulsion in carbon dioxide to overcome these disadvantages. The microemulsion is the clear solution that contains the water, surfactant and carbon dioxide. The surfactant surrounded the droplet into carbon dioxide and this state is thermodynamically stable. That is, the microemulsion has a structure similar to that of a conventional water-based surfactant system. Generally, the size of droplet is about 5 ∼ 10nm. The microemulsion is able to decontaminate radioactive waste so that the polar substance is removed by water and the non-polar substance is removed by carbon dioxide. After the decontamination process, the microemulsion is separated easily to surfactant and water by decreasing the pressure under the cloud point. This way, only radioactive wastes are left in the system. Cleaned carbon dioxide is then collected and reused. Thus, there are no secondary wastes. Carbon dioxide is considered an alternative process medium. This is because it is non-toxic, non-flammable, inexpensive and easy to handle. Additionally, the tunable properties of carbon dioxide through pressure and temperature control are versatile for use in extracting organic materials. In this paper, we examine the
Kit systems for granulated decontamination formulations
Tucker, Mark D.
2010-07-06
A decontamination formulation and method of making that neutralizes the adverse health effects of both chemical and biological compounds, especially chemical warfare (CW) and biological warfare (BW) agents, and toxic industrial chemicals. The formulation provides solubilizing compounds that serve to effectively render the chemical and biological compounds, particularly CW and BW compounds, susceptible to attack, and at least one reactive compound that serves to attack (and detoxify or kill) the compound. The formulation includes at least one solubilizing agent, a reactive compound, a sorbent additive, and water. A highly adsorbent sorbent additive (e.g., amorphous silica, sorbitol, mannitol, etc.) is used to "dry out" one or more liquid ingredients into a dry, free-flowing powder that has an extended shelf life, and is more convenient to handle and mix in the field. The formulation can be pre-mixed and pre-packaged as a multi-part kit system, where one or more of the parts are packaged in a powdered, granulated form for ease of handling and mixing in the field.
Decontaminating products for routine decontamination in nuclear power plants
International Nuclear Information System (INIS)
Henning, K.
2001-01-01
Routine decontamination work that has to be carried out in practical operation includes the cleaning of all kinds of surfaces such as floors, walls and apparatus, the decontamination of professional clothes and of the personnel. In order to ensure a trouble-free functioning of plants for the treatment of waste water and concentrate in nuclear power plants, radioactive liquid wastes appearing in the controlled area should be compatible with the treatment methods in practice. Radioactive concentrates and resides obtained from the treatment methods are mixed with matrix materials like cement or bitumen or treated by roller frame drying and thus are conditioned for intermediate or final storage. Several requirements should be made on decontaminating agents used in the controlled area. Some of these physical-chemical criteria will be described in detail. (R.P.)
Recommendations for skin decontamination
International Nuclear Information System (INIS)
1989-01-01
Further to the reecommendations for determining the surface contamination of the skin and estimating the radiation exposure of the skin after contamination (SAAS-Mitt--89-16), measures for skin decontamination are recommended. They are necessary if (1) after simple decontamination by means of water, soap and brush without damaging the skin the surface contamination limits are exceeded and the radiation exposure to be expected for the undamaged healthy skin is estimated as to high, and if (2) a wound is contaminated. To remove skin contaminations, in general universally applicable, non-aggressive decontamination means and methods are sufficient. In special cases, nuclide-specific decontamination is required taking into account the properties of the radioactive substance
An exposure system for measuring nasal and lung uptake of vapors in rats
Energy Technology Data Exchange (ETDEWEB)
Dahl, A.R.; Brookins, L.K.; Gerde, P. [National Inst. for Working Life, Solna (Sweden)
1995-12-01
Inhaled gases and vapors often produce biological damage in the nasal cavity and lower respiratory tract. The specific site within the respirator tract at which a gas or vapor is absorbed strongly influences the tissues at risk to potential toxic effects; to predict or to explain tissue or cell specific toxicity of inhaled gases or vapors, the sites at which they are absorbed must be known. The purpose of the work reported here was to develop a system for determining nose and lung absorption of vapors in rats, an animal commonly used in inhalation toxicity studies. In summary, the exposure system described allows us to measure in the rate: (1) nasal absorption and desorption of vapors; (2) net lung uptake of vapors; and (3) the effects of changed breathing parameters on vapor uptake.
Exposure management in a hot-cell decontamination and refurbishment campaign
International Nuclear Information System (INIS)
Courtney, J.C.; Ferguson, K.R.; Chesnovar, D.L.; Huebner, M.F.
1984-01-01
We developed a minicomputer-based system to provide rapid access to personnel dosimetry data during a campaign to decontaminate and refurbish a hot-cell at the Hot Fuel Examination Facility (HFEF) Complex. This system allows project management to estimate doses for future tasks, assess the effectiveness of decontamination and personnel protection techniques, and balance exposures among members of various skill groups. As the campaign progresses, projected total exposures can be minimized by tradeoffs between estimated doses during decontamination and estimated dose savings during the refurbishment phase. The effectiveness of various dose-reduction procedures can be compared on the basis of data from a few cell entries before more extensive routine operations are scheduled. Because the radiation fields vary significantly with location in the cell, we find that measurements of whole-body, skin, and extremity doses are more valuable than dose-rate information. Penetrating and skin radiation doses to personnel can be compared to administrative guidelines. This helps us to select the most effective combination of protective clothing. For example, leaded gauntlets reduce the dose rate to the workers' hands, but their use can increase the time required for some in-cell tasks. Hence, use of gauntlets can lead to higher whole-body and skin doses. The program is written for the HFEF Complex Harris/6 minimainframe computer with a disk-monitor operating system
Decontamination Data - Blister Agents
U.S. Environmental Protection Agency — Decontamination efficacy data for blister agents on various building materials using various decontamination solutions. This dataset is associated with the following...
Decontamination effects of a simulated contaminated floor surface by a teleoperated mopping system
International Nuclear Information System (INIS)
Kim, Ki Ho; Kwon, Hyok Jo; Park, Jang Jin; Yang, Myung Seung
2004-01-01
A Tele Operated Mopping System (TOMS) was developed for use in the radioactive zone of the M6 hot-cell of the Irradiated Material Examination Facility (IMEF) at the Korea Atomic Energy Research Institute (KAERI). TOMS was designed to remove contaminated dry particulates, dust, and smears existing on the floor surface of the M6 hot-cell by mopping it in a remote manner. TOMS has three subsystems - a mobile mopping slave located inside the hot-cell, and a mopping master and a control console located outside the hot-cell. The mobile mopping slave consists of a tracked mobile platform, a mopping tool, and a wet mopping cloth, which were constructed in modules to facilitate a maintenance. This paper aims at describing the mopping capability of the developed TOMS - decontamination capability. In this work the decontamination capability is defined by the ratio of the removed contaminated area when the mopping cloth was passed over. The experiment was carried out by varying the speeds of the mopping slave and the roller, while the mopping force driven by the operator was constant. The roller of the mopping tool mounted on the mopping slave was designed to collect the mopping cloth used. The experimental results showed that the speeds of the mopping slave and the roller influence the extent of the decontamination
Assessing cost and effectiveness of radiation decontamination in Fukushima Prefecture, Japan
International Nuclear Information System (INIS)
Yasutaka, Tetsuo; Naito, Wataru
2016-01-01
Despite the enormous cost of radiation decontamination in Fukushima Prefecture, it is not clear what levels of reduction in external radiation exposure are possible in the Special Decontamination Area, the Intensive Contamination Survey Areas and the whole of Fukushima. The objective of this study was to evaluate the cost and effectiveness of radiation decontamination in Fukushima Prefecture in its entirety. Using a geographic information system, we calculated the costs of removal, storage containers, transport, and temporary and interim storage facilities as well as the reduction in air dose rate for a cumulative external exposure for 9000 1 km × 1 km mesh units incorporating 51 municipalities. The decontamination cost for the basic scenario, for which forested areas within 20 m of habitation areas were decontaminated, was JPY2.53–5.12 trillion; the resulting reduction in annual external dose was about 2500 person-Sv. The transport, storage, and administrative costs of decontamination waste and removed soil reached JPY1.55–2.12 trillion under this scenario. Although implementing decontamination of all forested areas provides some major reductions in the external radiation dose for the average inhabitant, decontamination costs could potentially exceed JPY16 trillion. These results indicate that technologies for reducing the volume of decontamination waste and removed soil should be considered to reduce storage costs and that further discussions about forest decontamination policies are needed. - Highlights: • Evaluation of cost and effectiveness of decontaminating Fukushima Prefecture. • Reductions in external exposure under various decontamination scenarios were similar. • Decontamination costs for the basic scenario were estimated at JPY2.53–5.12 trillion.
Fast sorting measurement technique to determine decontamination priority
International Nuclear Information System (INIS)
Distenfeld, C.H.; Brosey, B.; Igarashi, H.
1986-01-01
The method used to select decontamination priorities for the Three Mile Island Unit 2 (TMI-2) reactor building (RB) is systematic, but costs in personnel exposure and time must be borne. One way of minimizing exposure is to define and treat the one or two surface sources that are important contributors to the collective dose of the recovery personnel. Surface characteristics can then be determined and decontamination techniques developed to match the removal requirements. At TMI-2, a fast sorting technique was developed and used to prioritize surfaces for exposure reduction. A second quick sort can then be used to determine the next generation of surface characterization, decontamination method selection, and performance. The quick-sort method that was developed is based on the Eberline HP 220A probes directional survey system. The angular response of the HP 220A probes approaches 2 pi steradians and allows toward-away type measurements. Sources distributed over 4 pi steradians are hard to define with this system. Angular differentiation was improved to about pi/2 steradians by redesigning the probe shield. The change allows unambiguous six-direction measurements, such as up, down, front, rear, right, and left with practically no angular overlap or exclusion. A simple, light-weight stand was used to establish an angular reference for the rectangular packaged probe. The six surface planes of the rectangle work with the angular reference to establish the six viewing angles
Development of the dry decontamination technique using plasma
Energy Technology Data Exchange (ETDEWEB)
Kim, Yong Soo; Seo, Yong Dae; Lee, Dong Uk; Jeon, Sang Hwan; Jung, Young Suk [Hanyang University, Seoul (Korea)
2001-04-01
In order to develop an advanced dry decontamination method, dry decontamination technique using gaseous plasma is studied. Scopes of the research are 1) literature survey and case studies of the international R and D activities and industrial application, 2) contaminant characteristics analysis, 3) feasibility and applicability study of the unit techniques, 4) process development study on the plasma decontamination, 5) plasma diagnostics and quantitative analysis by QMS and OES, and 6) design of (microwave) plasma torch system. The major research results are as belows. The maximum etching rate of UO{sub 2} is achieved to be 0.8 {mu}m/min. under 300 deg C, 150 W CF{sub 4}/O{sub 2}/N{sub 2} r.f. plasma maintaining the optimum ratio of CF{sub 4}/O{sub 2} of four, and that of Co and Mo is 0.06 {mu}m/min. and 1.9 {mu}m/min., respectively, under 380 deg C, 220 W CF{sub 4}/O{sub 2} r.f. plasma. The optimum process for the dry decontamination of TRU, CP, and or FP nuclides, therefore, requires the optimum gas composition above 350 deg C and 220W power. It is also demonstrated that this optimum process can be extrapolated to atmospheric high power torch system. In conclusion, if plasma power and temperature increases with maintaining the optimum gas composition, this dry decontamination techniques must be definitely effective and efficient. 17 refs., 62 figs., 4 tabs. (Author)
Surface decontamination using dry ice snow
International Nuclear Information System (INIS)
Ryu, Jungdong; Park, Kwangheon; Lee, Bumsik; Kim Yangeun
1999-01-01
An adjustable nozzle for controlling the size of dry ice snow was developed. The converging/diverging nozzle can control the size of snows from sub-microns to 10 micron size. Using the nozzle, a surface decontamination device was made. The removal mechanisms of surface contaminants are mechanical impact, partial dissolving and evaporation process, and viscous flow. A heat supply system is added for the prevention of surface ice layer formation. The cleaning power is slightly dependent on the size of snow. Small snows are the better in viscous flow cleaning, while large snows are slightly better in dissolving and sublimation process. Human oils like fingerprints on glass were easy to remove. Decontamination ability was tested using a contaminated pump-housing surface. About 40 to 80% of radioactivity was removed. This device is effective in surface-decontamination of any electrical devices like detector, controllers which cannot be cleaned in aqueous solution. (author)
Energy Technology Data Exchange (ETDEWEB)
Mestre, E.; Sautiez, N.
1957-10-15
With the objective of notably addressing the contamination and decontamination of gloves and floor covering, this report first presents some characteristics of contaminating radioactive materials (nature, physical and chemical condition), of contaminated surfaces (surface condition, surface nature), and of decontamination processes (physical, chemical or mechanical action). It describes the operational modality implemented to test decontamination processes on various glove or flooring materials: sample preparation, counting, decontamination, reproducibility of decontamination tests, results in terms of activity reduction. It more precisely describes the tested samples: short gloves, gloves from glove boxes, floor and wall coverings. Results are presented and discussed in terms of sample susceptibility to contamination, and of decontamination, but also for re-contamination tests after a Nab-based decontamination (susceptibility to contamination, decontamination gain)
Dalton, Christopher H; Hall, Charlotte A; Lydon, Helen L; Chipman, J K; Graham, John S; Jenner, John; Chilcott, Robert P
2015-05-01
The risk of penetrating, traumatic injury occurring in a chemically contaminated environment cannot be discounted. Should a traumatic injury be contaminated with a chemical warfare (CW) agent, it is likely that standard haemostatic treatment options would be complicated by the need to decontaminate the wound milieu. Thus, there is a need to develop haemostatic products that can simultaneously arrest haemorrhage and decontaminate CW agents. The purpose of this study was to evaluate a number of candidate haemostats for efficacy as skin decontaminants against three CW agents (soman, VX and sulphur mustard) using an in vitro diffusion cell containing undamaged pig skin. One haemostatic product (WoundStat™) was shown to be as effective as the standard military decontaminants Fuller's earth and M291 for the decontamination of all three CW agents. The most effective haemostatic agents were powder-based and use fluid absorption as a mechanism of action to sequester CW agent (akin to the decontaminant Fuller's earth). The envisaged use of haemostatic decontaminants would be to decontaminate from within wounds and from damaged skin. Therefore, WoundStat™ should be subject to further evaluation using an in vitro model of damaged skin. Copyright © 2014 Crown copyright. Journal of Applied Toxicology © 2014 John Wiley & Sons, Ltd.
Dilute chemical decontamination resins and the mixed waste issue
International Nuclear Information System (INIS)
Denault, R.P.; Hallman, J.T.
1988-01-01
The decontamination of reactor primary systems, sub-systems and components is an important method used to reduce the occupational radiation exposure of nuclear plant personnel. The waste produced by the application of this technology is mainly solid in the form of ion exchange resins. As a result of a recent agreement between the Environmental Protection Agency (EPA) and the Nuclear Regulatory Commission (NRC), all radioactive waste must meet EPA burial criteria. The chemicals used in a decontamination and certain metals dissolved during the process, primarily chromium, could render the waste hazardous as well as radioactive or more commonly called a mixed waste. This paper defines mixed waste as described in the EPA directive 9432.00-2, and examine the criteria by which waste is categorized as hazardous. The decontamination waste resin generated by two processes, the CAN-DEREM and the LOMI process, is described in detail. Waste data obtained from decontaminations performed by LN Technologies Corporation including chemical, metal and radionuclide loadings on resins from both PWR and BWR applications are presented
Monitoring of electrokinetic in-situ-decontamination
Energy Technology Data Exchange (ETDEWEB)
Goldmann, T. [INTUS Inst. fuer Technologie und Umweltschutz e.V., Berlin (Germany)
2001-07-01
The need for a monitoring system for in-situ soil decontamination is two-fold: Firstly, to ensure that remediation is attained and secondly to minimize costs and treatment time. A further reason is the potential risk of unexpected mobilization or chemical generation of hazardous compounds which could result in an extension of the contamination into other regions of soil, the ground water or the atmosphere. Electrokinetic in-situ decontamination is based on transport processes in the ground that proceed with relatively low velocity. This results in treatment times of several months. Since the transport processes can be described by a mathematical model, monitoring should always be combined with qualified mathematical processing. This makes it possible to estimate treatment time and costs to be expected. The challenge of in-situ monitoring is to identify relevant parameters describing the state of the ground. These parameters must be independent from influences like weather but they must be sensitive to changes of soil characteristics. In the case of electrokinetic soil remediation, probes and sensors must be resistant to influences of electric fields. The function of sensors or measuring systems can be disturbed or even damaged or destroyed by electric fields (for example by electro-corrosion). (orig.)
Planning guidance for nuclear-power-plant decontamination. [PWR; BWR
Energy Technology Data Exchange (ETDEWEB)
Munson, L.F.; Divine, J.R.; Martin, J.B.
1983-06-01
Direct and indirect costs of decontamination are considered in the benefit-cost analysis. A generic form of the benefit-cost ratio is evaluated in monetary and nonmonetary terms, and values of dollar per man-rem are cited. Federal and state agencies that may have jurisiction over various aspects of decontamination and waste disposal activities are identified. Methods of decontamination, their general effectiveness, and the advantages and disadvantages of each are outlined. Dilute or concentrated chemical solutions are usually used in-situ to dissolve the contamination layer and a thin layer of the underlying substrate. Electrochemical techniques are generally limited to components but show high decontamination effectiveness with uniform corrosion. Mechanical agents are particularly appropriate for certain out-of-system surfaces and disassembled parts. These processes are catagorized and specific concerns are discussed. The treatment, storage, and disposal or discharge or discharge of liquid, gaseous, and solid wastes generated during the decontamination process are discussed. Radioactive and other hazardous chemical wastes are considered. The monitoring, treatment, and control of radioactive and nonradioactive effluents, from both routine operations and possible accidents, are discussed. Protecting the health and safety of personnel onsite during decontamination is of prime importance and should be considered in each facet of the decontamination process. The radiation protection philosophy of reducing exposure to levels as low as reasonably achievable should be stressed. These issues are discussed.
PNL size reduction and decontamination facilities and capabilities
International Nuclear Information System (INIS)
Allen, R.P.; Fetrow, L.K.; McCoy, M.W.
1983-07-01
Studies sponsored by the US Department of Energy at Pacific Northwest Laboratory (PNL) have resulted in the development of an effective, integrated size reduction and decontamination system for transuranically contaminated components. Using this system, a reduction of more than 95% in the volume of transuranic waste requiring interim storage and eventual geologic disposal has been achieved for typical plutonium contaminated glove boxes. This paper describes the separate preparation, size reduction, decontamination and waste treatment operations and facilities that have been developed and demonstrated as part of this work
Thermodynamic performance analysis of a vapor compression–absorption cascaded refrigeration system
International Nuclear Information System (INIS)
Jain, Vaibhav; Kachhwaha, S.S.; Sachdeva, Gulshan
2013-01-01
Highlights: • Study includes first and second law analysis with alternatives refrigerants. • Power consumption in cascaded system is 61% less than vapor compression system. • COP of compression system is improved by 155% with cascaded absorption system. • Condenser is more sensitive to external fluid temperature as compare to evaporator. - Abstract: In the present study, a thermodynamic model for cascaded vapor compression–absorption system (CVCAS) has been developed which consists of a vapor compression refrigeration system (VCRS) coupled with single effect vapor absorption refrigeration system (VARS). Based on first and second laws, a comparative performance analysis of CVCAS and an independent VCRS has been carried out for a design capacity of 66.67 kW. The results show that the electric power consumption in CVCAS is reduced by 61% and COP of compression section is improved by 155% with respect to the corresponding values pertaining to a conventional VCRS. However there is a trade-off between these parameters and the rational efficiency which is found to decrease to half of that for a VCRS. The effect of various operating parameters, i.e., superheating, subcooling, cooling capacity, inlet temperature and the product of effectiveness and heat capacitance of external fluids are extensively studied on the COP, total irreversibility and rational efficiency of the CVCAS. Besides, the performance of environment friendly refrigerants such as R410A, R407C and R134A is found to be almost at par with that of R22. Hence, all the alternative refrigerants selected herein can serve as potential substitutes for R22. Furthermore, it has been found that reducing the irreversibility rate of the condenser by one unit due to decrease in condenser temperature depicted approximately 3.8 times greater reduction in the total irreversibility rate of the CVCAS, whereas unit reduction in the evaporator’s irreversibility rate due to increase in evaporator temperature reduced
Electrolytic decontamination of conductive materials for hazardous waste management
International Nuclear Information System (INIS)
Wedman, D.E.; Martinez, H.E.; Nelson, T.O.
1996-01-01
Electrolytic removal of plutonium and americium from stainless steel and uranium surfaces has been demonstrated. Preliminary experiments were performed on the electrochemically based decontamination of type 304L stainless steel in sodium nitrate solutions to better understand the metal removal effects of varying cur-rent density, pH, and nitrate concentration parameters. Material removal rates and changes in surface morphology under these varying conditions are reported. Experimental results indicate that an electropolishing step before contamination removes surface roughness, thereby simplifying later electrolytic decontamination. Sodium nitrate based electrolytic decontamination produced the most uniform stripping of material at low to intermediate pH and at sodium nitrate concentrations of 200 g L -1 and higher. Stirring was also observed to increase the uniformity of the stripping process
Molecular composition of vapor in the NaF-ZrF4 system
International Nuclear Information System (INIS)
Korenev, Yu.M.; Sidorov, L.N.; Rykov, A.N.; Novoselova, A.V.
1980-01-01
The NaF-ZrF 4 system is studied. It is established that Na 2 ZrF 6 , NaZrF 5 , (NaZrF 5 ) 2 , NaZr 2 F 9 complex molecules are present in the saturated vapor alongside with pure components. Partial pressures of all vapor components are determined. The values of partial pressure and evaporation heat have been used to calculate the vapor composition above the system; T-x and P-T projections of the phase diagram of the NaF-ZrF 4 system are plotted
Decontamination of paint-coated concrete in nuclear plants using laser technology
Energy Technology Data Exchange (ETDEWEB)
Anthofer, Anton; Lippmann, Wolfgang; Hurtado, Antonio [Technische Univ. Dresden (Germany). Chair of Hydrogen and Nuclear Technology
2013-07-01
A review of the state of the art shows the technical novelty of the combined project. The development of an all-in-one process for treatment hazard chemical contamination on concrete structures with online monitoring method reduces the laborious mechanic decontamination and post-treatment. For safe experimental investigations, a three-barrier-system was constructed and can be used for tests with - first - epoxy paint in order to analyze and optimize the process. Simulation models help to formulate a mathematic scheme of the decontamination process by laser technology. The goal is a decontamination system with an online analyzing system of the flue gas for a mobile and extensive component in nuclear and conventional decommission. (orig.)
Decontamination of CAGR gas circulator components
International Nuclear Information System (INIS)
Rogers, L.N.; Hooper, A.J.
1985-01-01
This paper describes the development and full-scale trial of two methods for removal of radioactive contamination on the surfaces of CAGR gas circulator components. The two methods described are a particle impact cleaning (PIC) decontamination technique and an electrochemical technique, 'electro-swabbing', which is based on the principle of decontamination by electro-polishing. In developing these techniques it was necessary to take account of the physical and chemical nature of the surface deposits on the gas circulator components; these were shown to consist of magnetite-type oxide and carbonaceous material. In order to follow the progress of the decontamination it was also necessary to develop a surface sampling technique which was effective and precise under these conditions; an electrochemical technique, employing similar principles to the electro-swabbing process, was developed for this purpose. The full-scale trial of the PIC decontamination technique was carried out on an inlet guide vane (IGV) assembly, this having been identified as the component from the gas circulator which contributes most to the radiation dose accumulated during routine circulator maintenance. The technique was shown to be practically viable and some 99% of the radioactive contamination was readily removed from the treated surfaces with only negligible surface damage being caused. The full-scale trial of the electro-swabbing decontamination technique was carried out on a gas circulator impeller. High decontamination factors were again achieved with ≥ 99% of the radioactive contamination being removed from the treated surfaces. The technique has practical limitations in terms of handling and treatment of waste-arisings. However, the use of specially-designed swabbing electrodes may allow the treatment of constricted geometries inaccessible to techniques such as PIC. The technique is also highly suitable for the treatment of soft-finish materials and of components fabricated from a
International Nuclear Information System (INIS)
Jain, Vaibhav; Sachdeva, Gulshan; Kachhwaha, S.S.
2015-01-01
Highlights: • It addresses the size and cost estimation of cascaded refrigeration system. • Cascaded system is a promising decarburizing and energy efficient technology. • Second law analysis is carried out with modified Gouy-Stodola equation. • The total annual cost of plant operation is optimized in present work. - Abstract: This paper addresses the size and cost estimation of vapor compression–absorption cascaded refrigeration system (VCACRS) for water chilling application taking R410a and water–LiBr as refrigerants in compression and absorption section respectively which can help the design engineers in manufacturing and experimenting on such kind of systems. The main limitation in the practical implementation of VCACRS is its size and cost which are optimized in the present work by implementing Direct Search Method in non-linear programming (NLP) mathematical model of VCACRS. The main objective of optimization is to minimize the total annual cost of system which comprises of costs of exergy input and capital costs in monetary units. The appropriate set of decision variables (temperature of evaporator, condenser, generator, absorber, cascade condenser, degree of overlap and effectiveness of solution heat exchanger) minimizes the total annual cost of VCACRS by 11.9% with 22.4% reduction in investment cost at the base case whereas the same is reduced by 7.5% with 11.7% reduction in investment cost with reduced rate of interest and increased life span and period of operation. Optimization results show that the more investment cost in later case is well compensated through the performance and operational cost of the system. In the present analysis, optimum cascade condensing temperature is a strong function of period of operation and capital recovery factor. The cascading of compression and absorption systems becomes attractive for lower rate of interest and increase life span and operational period
Recent developments in collaborative CBRN decontamination science : a retrospective
Energy Technology Data Exchange (ETDEWEB)
Yanofsky, N. [Defence Research and Development Canada, Ottawa, ON (Canada); Volchek, K.; Fingas, M. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch; Filatov, B. [Research Inst. of Hygiene, Toxicology and Occupational Pathology, Volgograd (Russian Federation)
2006-07-01
The importance of addressing the risk of chemical, biological and radiological/nuclear (CBRN) attacks was discussed with particular reference to recent developments in Canadian-led decontamination studies as part of the remediation response to a terrorist attack. Research efforts have been supported by government programs such as the CBRN Research and Technology Initiative of Defence Research and Development Canada and the Global Partnership Program of the Department of Foreign Affairs. In 2005, Environment Canada and Defence Research and Development Canada co-organized an international workshop with the Research Institute of Health, Toxicology and Occupational Pathology of Volgograd, Russia. The workshop brought together researchers from Canada, Russia, United States, United Kingdom, Netherlands, Poland and Bulgaria, with the view to eventually develop longer term collaborations. The theme focused on membrane technology and its application in CBRN decontamination. This paper reviewed these collaborative and international research efforts and identified areas in need of future work, such as bioremediation and radio-nuclear remediation. It addressed issues supporting a collaborative international research agenda in decontamination science; membrane filtration as a feasible approach to decontamination waste treatment; and possible areas of CBRN collaboration. It was suggested that the key to successful decontamination requires the creation of computer systems for the initial identification of chemical substances; complete toxicological characterization of the most dangerous agents; regulatory safety standards; quantitative determination of chemical substances; antidotes for most chemical threat agents; universal decontamination agents; and, validation of criteria for decontaminating buildings. The question of who pays for decontamination, be it the private or public sector, was also discussed.
Investigation on safety of gel decontamination technology
International Nuclear Information System (INIS)
Liu Zhihui; Song Fengli; Wang Yongxian; Zhang Taoge
2014-01-01
Gel decontamination technology is an advanced decontamination process of metal contaminated by radionuclide. It has the advantages such as simple operation process, high decontaminating factor, etc. But the disadvantages are that it has high spraying pressure and is strongly corrosive, which has safety risk to the operator and equipment. The effect of such factors as spraying pressure on operators was analyzed based on process feature, and it is proposed that it be worthwhile to make further study on the corrosion of gels to spraying equipment, taking into account corrosion feature of gels to stainless steel. Meanwhile, the safety issue was demonstrated on collecting and handling wastes from gel decontamination process. And then, protective measures, study methods, and solutions are put forward. The results show that protection should be strengthened during spraying to reduce the effect of splashing and fogging on workers; the equipment should be cleaned in time to reduce the effect of corrosion, and reducers should be added into waste liquid to eliminate the effect of residual detergent. (authors)
Criteria for the evaluation of a dilute decontamination demonstration
International Nuclear Information System (INIS)
FitzPatrick, V.F.; Divine, J.R.; Hoenes, G.R.; Munson, L.F.; Card, C.J.
1981-12-01
This document provides the prerequisite technical information required to evaluate and/or develop a project to demonstrate the dilute chemical decontamination of the primary coolant system of light water reactors. The document focuses on five key areas: the basis for establishing programmatic prerequisites and the key decision points that are required for proposal evaluation and/or RFP (Request for Proposal) issuance; a technical review of the state-of-the-art to identify the potential impacts of a reactor's primary-system decontamination on typical BWR and PWR plants; a discussion of the licensing, recertification, fuel warranty, and institutional considerations and processes; a preliminary identification and development of the selection criteria for the reactor and the decontamination process; and a preliminary identification of further research and development that might be required
The costs and effectiveness of various decontamination procedures
International Nuclear Information System (INIS)
Robinson, C.A.; Haywood, S.M.; Brown, J.
1991-01-01
Knowledge of the cost and effectiveness of decontamination techniques is necessary to optimise the implementation of this countermeasure. These factors vary depending upon the nature of the land affected. There is a great deal of data available on the cost and efficacy of specific decontamination techniques on particular surfaces, but little information for combinations of techniques in real environments. This paper describes the preliminary stages of a project, in progress at the National Radiological Protection Board (NRPB), aimed at providing this information, for inner city, residential and rural areas. The efficacies of individual decontamination processes on specific surfaces were from the available literature. The NRPB EXPURT (EXPosure from Urban Radionuclide Transfer) compartmental model was used to determine the effectiveness of a number of representative decontamination programmes; each programme represents a combination of common decontamination techniques which may be applied to the various surfaces comprising an inner-city, residential or rural environment, ie, paving, walls, roofs and soil. The effectiveness of each programme was measured in terms of the reduction in dose, or dose rate, to an individual in that environment, taking account of the building characteristics, and the occupancy of the population in these buildings. The costs of each programme were derived, based on data available in current literature on the cost of the constituent decontamination techniques. Representative cost and effectiveness data are presented and their application is discussed
Assessing cost and effectiveness of radiation decontamination in Fukushima Prefecture, Japan.
Yasutaka, Tetsuo; Naito, Wataru
2016-01-01
Despite the enormous cost of radiation decontamination in Fukushima Prefecture, it is not clear what levels of reduction in external radiation exposure are possible in the Special Decontamination Area, the Intensive Contamination Survey Areas and the whole of Fukushima. The objective of this study was to evaluate the cost and effectiveness of radiation decontamination in Fukushima Prefecture in its entirety. Using a geographic information system, we calculated the costs of removal, storage containers, transport, and temporary and interim storage facilities as well as the reduction in air dose rate for a cumulative external exposure for 9000 1 km × 1 km mesh units incorporating 51 municipalities. The decontamination cost for the basic scenario, for which forested areas within 20 m of habitation areas were decontaminated, was JPY2.53-5.12 trillion; the resulting reduction in annual external dose was about 2500 person-Sv. The transport, storage, and administrative costs of decontamination waste and removed soil reached JPY1.55-2.12 trillion under this scenario. Although implementing decontamination of all forested areas provides some major reductions in the external radiation dose for the average inhabitant, decontamination costs could potentially exceed JPY16 trillion. These results indicate that technologies for reducing the volume of decontamination waste and removed soil should be considered to reduce storage costs and that further discussions about forest decontamination policies are needed. Copyright © 2015 Elsevier Ltd. All rights reserved.
Long lasting decontamination foam
Demmer, Ricky L.; Peterman, Dean R.; Tripp, Julia L.; Cooper, David C.; Wright, Karen E.
2010-12-07
Compositions and methods for decontaminating surfaces are disclosed. More specifically, compositions and methods for decontamination using a composition capable of generating a long lasting foam are disclosed. Compositions may include a surfactant and gelatin and have a pH of less than about 6. Such compositions may further include affinity-shifting chemicals. Methods may include decontaminating a contaminated surface with a composition or a foam that may include a surfactant and gelatin and have a pH of less than about 6.
International Nuclear Information System (INIS)
Stefanik, J.
2001-01-01
The specifications laid down in this International Standard apply to the testing of surfaces which may become contaminated by radioactive materials. Decontaminability data obtained using this test method are not applicable to technical systems where layers of contaminating materials are formed as a result of long-term application of higher temperatures and pressures (for example primary circuits of nuclear reactors). The purpose of the test is to assess the ease of decontamination of surfaces under laboratory conditions. In practical applications, it may be important to consider other qualities, such as chemical, mechanical and radiation resistance and long-term stability in the selection of the materials to be used. It should be recognized that further decontamination tests under simulated service conditions may be needed
WIS decontamination factor demonstration test with radioactive nuclides
International Nuclear Information System (INIS)
Kanbe, Hiromi; Mayuzumi, Masami; Ono, Tetsuo; Nagae, Madoka; Sekiguchi, Ryosaku; Takaoku, Yoshinobu.
1987-01-01
A radioactive Waste Incineration System (WIS) with suspension combustion is noticed as effective volume reduction technology of low level radiactive wastes that are increasing every year. In order to demonstrate the decontamination efficiency of ceramic filter used on WIS, this test has been carried out with the test facilities as joint research of Central Research Institute of Electric Power Industry (CRIEPI) and Sumitomo Heavy Industries, Ltd. Miscellaneous combustible waste and power resin, to which 5 nuclides (Mn-54, Fe-59, Co-60, Zn-65, Cs-137) were added, were used as samples for incineration. As the result of the test, it was verified that Decontamination Factor (DF) of the single stage ceramic filter was usually kept over 10 5 for every nuclide, and from the results of above DF, over 10 8 is expected for real commercial plant as a total system. Therefore, it is realized that the off-gas clean up system of the WIS composed of only single stage of ceramic filter is capable of sufficiently efficient decontamination of exhaust gas to be released to stack. (author)
DECONTAMINATION/DESTRUCTION TECHNOLOGY DEMONSTRATION FOR ORGANICS IN TRANSURANIC WASTE
Energy Technology Data Exchange (ETDEWEB)
Chris Jones; Javier Del Campo; Patrick Nevins; Stuart Legg
2002-08-01
The United States Department of Energy's Savannah River Site has approximately 5000 55-gallon drums of {sup 238}Pu contaminated waste in interim storage. These may not be shipped to WIPP in TRUPACT-II containers due to the high rate of hydrogen production resulting from the radiolysis of the organic content of the drums. In order to circumvent this problem, the {sup 238}Pu needs to be separated from the organics--either by mineralization of the latter or by decontamination by a chemical separation. We have conducted ''cold'' optimization trials and surrogate tests in which a combination of a mediated electrochemical oxidation process (SILVER II{trademark}) and ultrasonic mixing have been used to decontaminate the surrogate waste materials. The surrogate wastes were impregnated with copper oxalate for plutonium dioxide. Our process combines both mineralization of reactive components (such cellulose, rubber, and oil) and surface decontamination of less reactive materials such as polyethylene, polystyrene and polyvinylchloride. By using this combination of SILVER II and ultrasonic mixing, we have achieved 100% current efficiency for the destruction of the reactive components. We have demonstrated that: The degree of decontamination achieved would be adequate to meet both WIPP waste acceptance criteria and TRUPACT II packaging and shipping requirements; The system can maintain near absolute containment of the surrogate radionuclides; Only minimal pre-treatment (coarse shredding) and minimal waste sorting are required; The system requires minimal off gas control processes and monitoring instrumentation; The laboratory trials have developed information that can be used for scale-up purposes; The process does not produce dioxins and furans; Disposal routes for secondary process arisings have already been demonstrated in other programs. Based on the results from Phase 1, the recommendation is to proceed to Phase 2 and use the equipment at Savannah
International Nuclear Information System (INIS)
Kunze, S.
1991-09-01
The sealing jointing compounds applied in practice and already examined for decontaminability will be presented here. Solvent-free sealing compounds, emulsifiable in water, with low molecular epoxy resins as binders, quite a number of curing versions, and little hygroscopic filler mixtures adapted in grain size have been tested with a view to ceramic tile jointing in nuclear facilities. The sealing compounds were examined before and after exposure to gamma irradiation (300 KGy energy dose) for decontaminability, color, gloss and resistance to decontaminants. Out of fourteeen compounds exhaustively investigated ten are very well decontaminable and four well decontaminable. After exposure to radiation no or only minor changes in color and gloss, respectively, were observed. Visible changes such as cracking, bubbles, etc. were not found and the resistance to decontaminants was neither affected. It has even been possible to replace in the well decontaminable sealing compounds developed until now part of the epoxy resin binder with elasticizing components such as Thiokol which is very important as a base material for sealing compounds in the construction industry, but difficult to decontaminate. (orig.) [de
Preconceptual design of the gas-phase decontamination demonstration cart
International Nuclear Information System (INIS)
Munday, E.B.
1993-12-01
Removal of uranium deposits from the interior surfaces of gaseous diffusion equipment will be a major portion of the overall multibillion dollar effort to decontaminate and decommission the gaseous diffusion plants. Long-term low-temperature (LTLT) gas-phase decontamination is being developed at the K-25 Site as an in situ decontamination process that is expected to significantly lower the decontamination costs, reduce worker exposure to radioactive materials, and reduce safeguard concerns. This report documents the preconceptual design of the process equipment that is necessary to conduct a full-scale demonstration of the LTLT method in accordance with the process steps listed above. The process equipment and method proposed in this report are not intended to represent a full-scale production campaign design and operation, since the gas evacuation, gas charging, and off-gas handling systems that would be cost effective in a production campaign are not cost effective for a first-time demonstration. However, the design presented here is expected to be applicable to special decontamination projects beyond the demonstration, which could include the Deposit Recovery Program. The equipment will therefore be sized to a 200 ft size 1 converter (plus a substantial conservative design margin), which is the largest item of interest for gas phase decontamination in the Deposit Recovery Program. The decontamination equipment will allow recovery of the UF 6 , which is generated from the reaction of ClF 3 with the uranium deposits, by use of NaF traps
International Nuclear Information System (INIS)
Takano, Takahiko; Ito, Kei; Takizawa, Koichi
2015-01-01
As for the decontamination of the soil contaminated with radioactive materials, decontamination is on the way in compliance with the 'Act on Special Measures Concerning the Handling of Environmental Pollution by Radioactive Materials by the NPS Accident Associated with the Tohoku District - Off the Pacific Ocean' (hereinafter, the Act on Special Measures). Tokyo Electric Power Company (TEPCO), as the party concerned to the accident, is cooperating with decontamination activities conducted by countries and municipalities under the Act on Special Measures. Total number of people cooperated by the Decontamination Promotion Office amounts to about 120,000 people. The cooperation to the decontamination by countries and municipalities covers the following fields: provision of knowledge of radiation, training of site management and supervisors, and proposal such as the decontamination method suitable for the site. As cooperation to various monitoring, there is a traveling monitoring that performs radiation measurement from the vehicles. As cooperation in the farming and industrial resumption toward the reconstruction, the group has implemented support for the distribution promotion of the holdup that was stuck in distribution due to contamination with radioactive substances. As decontamination related technology, the following are performed: (1) preparation of radiation understanding promotion tool, (2) development of precise individual dose measurement technology, and (3) development and utilization of decontamination effect analysis program. In the future, this group will perform the follow-up for decontamination, and measures toward the lifting of evacuation order. It will install the basis to perform various technical analyses on decontamination, and will further intensify technical cooperation. (A.O.)
International Nuclear Information System (INIS)
Choi, B. S.; Yoon, S. B.; Jung, C. H.; Lee, K. W.; Moon, J. K.
2012-01-01
Silica-based chemical gel for the decontamination of nuclear facilities was prepared by using fumed silica as a viscosifier, a 0.5 M Ce (IV) solution dissolved in concentrated nitric acid as a chemical decontamination agent, and tripropylene glycol butyl ether (TPGBE) as a co-viscosifier. A new effective strategy for the preparation of the chemical gel was investigated by introducing the alkyl alcohols as organic solvents to effectively dissolve the co-viscosifier. The mixture solution of the co-viscosifier and alkyl alcohols was more effective in the control of viscosity than that of the co-viscosifier only in gel. Here, the alkyl alcohols played a key role as an effective dissolution solvent for the co-viscosifier in the preparation of the chemical gel, resulting in a reducing of the amount of the co-viscosifier and gel time compared with that of the chemical gel prepared without the alkyl alcohols. It was considered that the alkyl alcohols contributed to the effective dissolution of the co-viscosifier as well as the homogeneous mixing in the formation of the gel, while the co-viscosifier in an aqueous media of the chemical decontamination agent solution showed a lower solubility. The decontamination efficiency of the chemical gels prepared in this work using a multi-channel analyzer (MCA) showed a high decontamination efficiency of over ca. 94% and ca. 92% for Co-60 and Cs-137 contaminated on surface of the stainless steel 304, respectively. (authors)
Vapor-liquid equilibria for the acetone-ethanol-n-propanol-tert-butanol-water system
Energy Technology Data Exchange (ETDEWEB)
Tochigi, K.; Uchida, K.; Kojima, K.
1981-12-01
This study deals with the measurement of vapor-liquid equilibria for the five-component system acetone-ethanol-n-propanol-tert-butanol-water at 760 mmHg and prediction of vapor-liquid equilibria by the ASOG group contribution method. The five-component system in this work is composed of a part of the components obtained during ethanol production by vapor-phase hydration of ethylene. 6 refs.
OECD/NEA Aagesta decontamination project. Phase 1, final report
International Nuclear Information System (INIS)
1982-12-01
The objective of the project is to utilize the four primary loops of the Aagesta reactor to demonstrate decontamination methods for PWR primary systems. The first phase of the project consisted of laboratory scale tests. The methods tested were developed at a) Studsvik Energiteknik AB, Sweden (a soft chemistry). b) Kraftwerk Union AG, Federal Republic of Germany, (two chemistries, one soft and one hard). c) Swiss Federal Institute of Reactor Research (two chemistries, one soft and one hard). d) Berkeley Nuclear Laboratories, United Kingdom, (a soft chemistry). The test programme consisted of decontamination tests on steam generator tubing and other active material from Aagesta and a number of operating reactors as well as material compatibility tests on standardized samples of a representative selection of modern PWR primary system materials. Six countries have participated in Phase I of the project - the four countries named above as well as the United States of America and Italy. Studsvik Energiteknik AB was appointed Project leader. The results show that all six processes in general met the acceptance criteria both regarding decontamination and corrosion. The decontamination results with the hard chemistries were rather uneven. (Author)
Study on LOMI decontamination technology
International Nuclear Information System (INIS)
Huang Fuduan; Yu Degui; Lu Jingju; Xie Yinyan
1993-10-01
The results of decontamination technique of Low-Oxidation-State Metal-Ion (LOMI) reagents developed from 1986 to 1991 in the laboratory are introduced. The experiments included preparation of LOMI reagents, de-filming efficiency, corrosion behavior of typical alloys, decontamination factors of reagents for contaminated materials and components have proved that the NP/LOMI decontamination method and treatment technique of waste water are feasible and have some advantages. The preparation of LOMI reagent with low concentration of formic acid by reduced pressure distilling technique and the utilization ratio of vanadium reached to 95% by second electrolysis are the main contributions of the study to the decontamination technique
Manual on decontamination of surfaces
International Nuclear Information System (INIS)
1979-01-01
The manual is intended for those who are responsible for the organization and implementation of decontamination programmes for facilities where radioactive materials are handled mainly on a laboratory scale. It contains information and guidelines on practical methods for decontaminating working spaces, equipment, laboratory benches and protective clothing. Useful information is also provided on the removal of loose skin contamination from personnel by mild, non-medical processes. Methods of removing skin contamination needing medical supervision, or of internal decontamination, which is entirely a medical process, are not covered in this manual. Large-scale decontamination of big nuclear facilities is also considered as outside its scope
Improvement of Vivarium Biodecontamination through Data-acquisition Systems and Automation.
Devan, Shakthi Rk; Vasu, Suresh; Mallikarjuna, Yogesha; Ponraj, Ramkumar; Kamath, Gireesh; Poosala, Suresh
2018-03-01
Biodecontamination is important for eliminating pathogens at research animal facilities, thereby preventing contamination within barrier systems. We enhanced our facility's standard biodecontamination method to replace the traditional foggers, and the new system was used effectively after creating bypass ducts in HVAC units so that individual rooms could be isolated. The entire system was controlled by inhouse-developed supervisory control and data-acquisition software that supported multiple cycles of decontamination by equipment, which had different decontamination capacities, operated in parallel, and used different agents, including H2O2 vapor and ClO2 gas. The process was validated according to facility mapping, and effectiveness was assessed by using biologic (Geobacillus stearothermophilus) and chemical indicator strips, which were positioned before decontamination, and by sampling contact plates after the completion of each cycle. The results of biologic indicators showed 6-log reduction in microbial counts after successful decontamination cycles for both agents and found to be compatible with clean-room panels including commonly used materials in vivarium such as racks, cages, trolleys, cage changing stations, biosafety cabinets, refrigerators and other equipment in both procedure and animal rooms. In conclusion, the automated process enabled users to perform effective decontamination through multiple cycles with realtime documentation and provided additional capability to deal with potential outbreaks. Enabling software integration of automation improved quality-control systems in our vivarium.
Development of Raman-Mie lidar system for aerosol and water vapor profiling
Deng, Qian; Wang, Zhenzhu; Xu, Jiwei; Tan, Min; Wu, Decheng; Xie, Chenbo; Liu, Dong; Wang, Yingjian
2018-03-01
Aerosol and water vapor are two important atmospheric parameters. The accurate quantification of diurnal variation of these parameters are very useful for environment assessment and climate change studies. A moveable, compact and unattended lidar system based on modular design is developed for aerosol extinction coefficients and water vapor mixing ratios measurements. In the southern suburbs of Beijing, the continuous observation was carried out by this lidar since the middle of the year of 2017. The lidar equipment is presented and the case study is also described in this paper. The observational results show that the lidar kept a very good status from the long-time continuous measurements which is suitable for networking especially in meteorological research field.
Decontamination tests on cotton materials; Essais de decontamination sur tissus de coton
Energy Technology Data Exchange (ETDEWEB)
Cohen, P; Pelletier, C [Commissariat a l' Energie Atomique, Saclay (France). Centre d' Etudes Nucleaires
1958-07-01
It is shown that versene gives the best decontamination results on cotton materials soiled by a mixture of fission products. (author) [French] On a montre que le versene donne les meilleurs resultats de decontamination sur des tissus de coton souilles par un melange de produits de fission. (auteur)
A Survey and Evaluation of Chemical Warfare Agent-Decontaminants and Decontamination
1984-10-15
Biological Methods. The use of a cell-free enzymatic system, microorganisms, algae, and the state-of-the-art genetic engineering approach for decontaminating...many organic and inorganic materials might react with agents in a manner similar to complex enzymatic reactions. However. experimental data were not...28). XXCC3 was further tested for use in a microencapsulation concept. Pre- liminary results indicated that O.30g of ethyl cellulose 21 microcapsules
Decontamination of Beaver Valley steam generators using the CAN-DEREM process
International Nuclear Information System (INIS)
Speranzini, R.A.; Helms, M.
1991-08-01
Three steam generator channelheads at the Beaver Valley Unit 1 Power Station were decontaminated in September and October of 1989 using the CAN-DEREM process. With system volumes of about 12 000 L for each steam generator, this was the first major application of the CAN-DEREM process, following closely after the successful 1989 April CAN-DEREM decontamination of a 1000 L Indian Point-2 recirculating heat exchanger. The Successful applications were the culmination of several years of laboratory study directed at assessing and subsequently altering the CAN-DECON formulation. The studies were initiated after the CAN-DECON process was implicated in causing intergranular attack in sensitized 304 stainless steel after the Peach Bottom-2 recirculating water cooling unit (RWCU) decontamination in early 1984. The degree of attack was similar to that observed on piping from several early Boiling Water Reactors, and this was the only instance of reactor artifacts revealing intergranular attack after a CAN-DECON decontamination. Nevertheless, utilities were reluctant to use CAN-DECON after the Peach Bottom-2 decontamination. In response the utility concerns, the CAN-DECON formulation was modified to produce the even-less-corrosive CAN-DEREM formulation. In this report, the results of the laboratory corrosion study are briefly summarized along with the results of pre-decontamination assessments using Beaver Valley specimens, and the results of the actual steam generator decontaminations. The results show quite clearly the decontamination effectiveness and the low corrosiveness of the CAN-DEREM process. As a result of the successful laboratory program and demonstrations, the CAN-DEREM process is currently being qualified for use in full heat transport systems of Pressurized Water Reactors in a major program being carried out by Westinghouse in the United States
Performance of vapor compression systems with compressor oil flooding and regeneration
Energy Technology Data Exchange (ETDEWEB)
Bell, Ian H.; Groll, Eckhard A.; Braun, James E. [Purdue University, Department of Mechanical Engineering, 140 S. Martin Jischke Drive, West Lafayette, IN 47906 (United States)
2011-01-15
Vapor compression refrigeration technology has seen great improvement over the last several decades in terms of cycle efficiency through a concerted effort of manufacturers, regulators, and research engineers. As the standard vapor compression systems approach practical limits, cycle modifications should be investigated to increase system efficiency and capacity. One possible means of increasing cycle efficiency is to flood the compressor with a large quantity of oil to achieve a quasi-isothermal compression process, in addition to using a regenerator to increase refrigerant subcooling. In theory, compressor flooding and regeneration can provide a significant increase in system efficiency over the standard vapor compression system. The effectiveness of compressor flooding and regeneration increases as the temperature lift of the system increases. Therefore, this technology is particularly well suited towards lower evaporating temperatures and high ambient temperatures as seen in supermarket refrigeration applications. While predicted increases in cycle efficiency are over 40% for supermarket refrigeration applications, this technology is still very beneficial for typical air-conditioning applications, for which improvements in cycle efficiency greater than 5% are predicted. It has to be noted though that the beneficial effects of compressor flooding can only be realized if a regenerator is used to exchange heat between the refrigerant vapor exiting the evaporator and the liquid exiting the condenser. (author)
Energy Technology Data Exchange (ETDEWEB)
NONE
1997-12-31
Progress reports are given on the following projects: (A) Subsurface contaminants, containment and remediation: 1.1 Characteristic evaluation of grout barriers in grout testing chamber; 1.2 Development of standard test protocols and barrier design models for desiccation barriers; 1.3 Development of standard test protocols and barrier design models for in-situ formed barriers -- technical support; 1.4 Laboratory studies and field testing at the DOE/RMI Extrusion Plant (Ashtabula, Ohio); 1.5 Use of drained enhanced soil flushing for contaminants removal; (B) Mixed waste characterization, treatment and disposal: Analysis of the Vortec cyclone melting system for remediation of PCB contaminated soils using computational fluid dynamics; (C) Decontamination and decommissioning: 3.1 Production and evaluation of biosorbents and cleaning solutions for use in D and D; 3.2 Use of Spintek centrifugal membrane technology and sorbents/cleaning solutions in the D and D of DOE facilities; (D) Cross-cutting innovative technologies: 4.1 Use of centrifugal membrane technology with novel membranes to treat hazardous/radioactive wastes; 4.2 Environmental pollution control devices based on novel forms of carbon; 4.3 Design of rotating membrane filtration system for remediation technologies; and (E) Outreach: Small business technical based support.
Decontamination of the equipment in the acids recovery cell in the fuel reprocessing plant
International Nuclear Information System (INIS)
Maki, Akira; Kusano, Toshitsugu
1985-01-01
In the cell where an acids recovery evaporator tank is set, there are also installed its associated components such as the solution feed system and a receiving tank. When maintenance etc. are to be conducted within the cell, the equipment etc. must be decontaminated to eliminate the personnel exposure. In the acid recovery process, there is involved ruthenium-106, for which the decontamination reagents must be selected. As such, the decontamination proceeded first with nitric acid + sodium hydroxide solution and then alkaline potassium permanganate solution + nitric acid + EDTA.2Na. Decontamination was made twice in 1979 and 1983. Described are the selection of decontamination reagents and decontamination works performed in the acids recovery cell. (Mori, K.)
Results of preliminary experiments on tritium decontamination by UV irradiation
International Nuclear Information System (INIS)
Oya, Yasuhisa; Shu, Wataru; O'hira, Shigeru; Hayashi, Takumi; Nishi, Masataka
2000-03-01
In the point of view of protection of workers from the radiation exposure and the limitation of the contamination with radioactive materials, it is important to decontaminate mobile tritium from plasma facing components of a nuclear fusion reactor at the beginning of their maintenance work. It is considered that the heating is the most effective method for decontamination. However, it is important to develop new decontamination method of adsorbed hydro-carbon based substances from the materials that cannot be heated or the inner pipe of double pipes. This report presents results of preliminary experiments performed for the development of the effective tritium decontamination technique pursuing under US/Japan collaborative program on technology for fusion-fuel processing (Annex IV). In the experiments, the effects of Ultra Violet (UV) irradiation on tritium removal from some kinds of materials, such as poly vinyl chloride -(CH 2 CHCl) n - film, polyethylene film and graphite samples coated by C 2 H 2 plasma were examined. As the result of UV irradiation, it was confined that hydrogen and carbon based compounds could be released from the specimen during UV irradiation. It is concluded that UV irradiation is one of the hopeful candidates for effective tritium decontamination. (author)
Decontamination of floor surfaces
International Nuclear Information System (INIS)
Smirous, F.
1983-01-01
Requirements are presented put on the surfaces of floors of radiochemical workplaces. The mechanism is described of retaining the contaminant in the surface of the flooring, ways of reducing the hazards of floor surface contamination, decontamination techniques and used decontamination agents. (J.P.)
Development of remote electrochemical decontamination for hot cell applications
International Nuclear Information System (INIS)
Turner, A.D.; Pottinger, J.S.; Lain, M.J.; Dawson, R.K.; Neville, M.D.; Junkison, A.R.
1988-01-01
The paper concerns the development and evaluation of remote electrochemical decontamination systems for metal surfaces, in connection with the decommissioning of nuclear installations. Two types of technique based on the electrochemical dissolution of thin surface layers of the substrate were investigated: immersion of small items in tanks for electroetching and in situ electropolishing. A description is given of the work programme, the progress of work and the results obtained. (U.K.)
International Nuclear Information System (INIS)
Endo, Kouzou
2013-01-01
For Fukushima prefecture having suffered from significant damage associated with the Great East Japan Earthquake and the nuclear power plant accident, the decontamination work is the most urgent issue. The paper reports the present situation of the remediation acts of Fukushima Government done since the accident, particular emphasis on the removal of radioactive substances due to cesium 137 in the residential area. Government supports to promote the decontamination work and its operators, and encourages employers and employees in their efforts, to set up temporary storages of the produced radioactive wastes, to cultivate and improve technical supports for decontamination work and strengthen understanding and support of the local resident, thus providing the training course for the site supervisors, the person engaged in the work and management. (S. Ohno)
Summary of decontamination cover manufacturing experience
International Nuclear Information System (INIS)
Ulrich, G.B.; Berry, H.W.
1995-02-01
Decontamination cover forming cracks and vent cup assembly leaks through the decontamination covers were early manufacturing problems. The decontamination cover total manufacturing process yield was as low as 55%. Applicable tooling and procedures were examined. All manufacturing steps from foil fabrication to final assembly leak testing were considered as possible causes or contributing factors to these problems. The following principal changes were made to correct these problems: (1) the foil annealing temperature was reduced from 1375 degrees to 1250 degrees C, (2) the decontamination cover fabrication procedure (including visual inspection for surface imperfections and elimination of superfluous operations) was improved, (3) the postforming dye penetrant inspection procedure was revised for increased sensitivity, (4) a postforming (prewelding) 1250 degrees C/1 h vacuum stress-relief operation was added, (5) a poststress relief (prewelding) decontamination cover piece-part leak test was implemented, (6) the hold-down fixture used during the decontamination cover-to-cup weld was modified, and concomitantly, and (7) the foil fabrication process was changed from the extruding and rolling of 63-mm-diam vacuum arc-remelted ingots (extrusion process) to the rolling of 19-mm-square arc-melted drop castings (drop cast process). Since these changes were incorporated, the decontamination cover total manufacturing process yield has been 91 %. Most importantly, more than 99% of the decontamination covers welded onto vent cup assemblies were acceptable. The drastic yield improvement is attributed primarily to the change in the foil annealing temperature from 1375 degrees to 1250 degrees C and secondarily to the improvements in the decontamination cover fabrication procedure
Decontamination Technology Development for Nuclear Research Facilities
International Nuclear Information System (INIS)
Oh, Won Zin; Jung, Chong Hun; Choi, Wang Kyu; Won, Hui Jun; Kim, Gye Nam
2004-02-01
Technology development of surface decontamination in the uranium conversion facility before decommissioning, technology development of component decontamination in the uranium conversion facility after decommissioning, uranium sludge treatment technology development, radioactive waste soil decontamination technology development at the aim of the temporary storage soil of KAERI, Optimum fixation methodology derivation on the soil and uranium waste, and safety assessment methodology development of self disposal of the soil and uranium waste after decontamination have been performed in this study. The unique decontamination technology applicable to the component of the nuclear facility at room temperature was developed. Low concentration chemical decontamination technology which is very powerful so as to decrease the radioactivity of specimen surface under the self disposal level was developed. The component decontamination technology applicable to the nuclear facility after decommissioning by neutral salt electro-polishing was also developed. The volume of the sludge waste could be decreased over 80% by the sludge waste separation method by water. The electrosorption method on selective removal of U(VI) to 1 ppm of unrestricted release level using the uranium-containing lagoon sludge waste was tested and identified. Soil decontamination process and equipment which can reduce the soil volume over 90% were developed. A pilot size of soil decontamination equipment which will be used to development of real scale soil decontamination equipment was designed, fabricated and demonstrated. Optimized fixation methodology on soil and uranium sludge was derived from tests and evaluation of the results. Safety scenario and safety evaluation model were development on soil and uranium sludge aiming at self disposal after decontamination
Energy Technology Data Exchange (ETDEWEB)
Song, Jong Soon; Jung, Min Young; Lee, Sang Heon [Chosun University, Gwangju (Korea, Republic of)
2016-03-15
Decontamination is one of the most important technologies for the decommissioning of NPP. The purpose of decontamination is to reduce the Risk of exposure of the decommissioning workers, and to recycle parts of the plant components. Currently, there is a lack of data on the efficiency of the decontamination technologies for decommissioning. In most cases, the local radiation level can be lowered below a regulatory limitation by decontamination. Therefore, more efficient decontamination technology must be continuously developed. This work describes the practical experiences in the United States and the European countries for NPP decommissioning using these decontamination technologies. When the decommissioning of domestic nuclear power plant is planned and implemented, this work will be helpful as a reference of previous cases.
Vapor-transport of tungsten and its geologic application
Energy Technology Data Exchange (ETDEWEB)
Shibue, Y [Hyogo Univ. of Teacher Education, Hyogo (Japan)
1988-11-10
The volatility of tungsten in a hydrous system at elevated temperatures and pressures was examined, and a tentative model for the enrichment of tungsten in hydrothermal solutions for the deposits related to granitic activities was proposed. To produce vapor-saturated solution, 17 or 15ml of 20wt% NaCl solution was introduced into an autoclave. Ca(OH){sub 2} for tungsten and H{sub 2}WO{sub 4} for base metals were used as vapor-captures, and run products were identified by X-ray powder diffractometry. The results suggested that the ratio of tungsten to base metals was higher in a vapor phase than in a liquid phase, and more enrichment of tungsten in the vapor phase occurred at higher temperature and pressure under the coexistence of the vapor and liquid phase. The tentative model emphasizing the vapor-transport of tungsten could explain the presence of tungsten deposits without large mineralization of base metals. Geological schematic model for the generation of the hydrothermal solution enriched in tungsten compared with base metals was illustrated based on above mentioned results. 21 refs., 3 figs.
Monitoring work at decontamination in Fukushima city
International Nuclear Information System (INIS)
Mori, Kazuyuki
2013-01-01
The author has been working at the decontamination site of Fukushima residences as a radiation monitor since Feb. 2012 for about 1 year, of which experiences are reported here. The decontamination conducted was legally based on the Act on Special Measures concerning the contamination by Fukushima Nuclear Power Plant Accident in Mar. 2011, and on other national, municipal related laws and guidelines. Fukushima city planned to conduct the decontamination for coming 5 years from Oct. 2011 to reduce its ambient dose rate to 9 sites within a residence. The work was managed with monitoring result cards and photographs. The definition of contamination to be cleared was against the dose rate of garden ground surface >30 Bq/cm 2 and of ambient at 1 m height 0.5-2 mc-Sv/h, the latter of which was aimed at reducing to <1 mc-Sv/h and the ambient at 1 cm height, to <0.4 mc-Sv. The ambient dose rate after decontamination of 717 residences has been found decreased to about a half (36-73% of doses before the work). Radiation hazard protection of workers was managed with the health examination defined by the law, education and pocket dosimeter: the exposure dose of the decontamination workers has been found to be about 5 mc-Sv/day. Finally, the report presents comments of thoughts and resolves of the city, executing trader, executer and monitoring staff. (T.T.)
Decontamination around the site of Chernobylsk; Decontamination autour du site de Tchernobyl
Energy Technology Data Exchange (ETDEWEB)
Manesse, D; Rzepka, J P; Maubert, H
1990-12-01
This report describes the decontamination of the site around the nuclear plant of Chernobylsk after the reactor accident of 1986. The work of decontamination in urban areas, buildings, fields and vegetation are detailed. The interventions to reduce the contamination of surface waters and to protect ground waters are also given. (N.C.).
Energy Technology Data Exchange (ETDEWEB)
Na, Young Su; Ha, Kwang Soon; Kim, Sungil; Cho, Song-Won [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2015-10-15
When the pressure in the containment building approaches a setting value, the FCVS(Filtered Containment Venting System) operates. The amount of steam and gas mixtures generated during a severe accident can be released into the FCVS. Non-condensable gases and fine aerosols can pass a scrubbing solution and the filters in the FCVS vessel. The decontaminated gases are finally discharged from the FCVS to the outside environment. Previous study observed that a scrubbing solution in the FCVS vessel was constantly evaporating owing to high-temperature steam released continuously from the containment building. A scrubbing solution in the FCVS vessel was completely evaporated at about 31 hours after the FCVS operation. Pool evaporation in the FCVS vessel can negatively affect the decontamination feature of the FCVS because it reduces the scrubbing depth for fission products in an aerosol form. This study carefully evaluated the decontamination factor of metal iodide aerosols especially cesium iodide (CsI), on a scrubbing solution in the FCVS. This paper summarizes the calculated results on the decontamination factor of CsI in the FCVS vessel, which was presented at the international OECD-NEA/NUGENIA-SARNET workshop. This study estimated the decontamination factor of CsI on a scrubbing solution in the FCVS. The MELCOR computer code simulated that an SBO occurred in the OPR 1000. The FCVS consists of a cylindrical vessel with a 3 m diameter and 6.5 m height, and it includes a scrubbing solution of 21 tons. Accumulated mass of CsI aerosol was calculated in a scrubbing solution and the atmosphere in the FCVS vessel and the outside environment. In the early FCVS operation, the decontamination factor of CsI aerosol rapidly increased owing to steam condensation in a scrubbing solution. When the temperature of a pool approached its saturation temperature, the decontamination factor of CsI aerosol started to decrease.
International Nuclear Information System (INIS)
Furukawa, Toshiharu; Shibuya, Kiichiro.
1985-01-01
Purpose: To provide a method of eliminating radioactive contaminations capable of ease treatment for decontaminated liquid wastes and grinding materials. Method: Those organic grinding materials such as fine wall nuts shell pieces cause no secondary contaminations since they are softer as compared with inorganic grinding materials, less pulverizable upon collision against the surface to be treated, being capable of reusing and producing no fine scattering powder. In addition, they can be treated by burning. The organic grinding material and water are sprayed by a nozzle to the surface to be treated, and decontaminated liquid wastes are separated into solid components mainly composed of organic grinding materials and liquid components mainly composed of water by filtering. The thus separated solid components are recovered in a storage tank for reuse as the grinding material and, after repeating use, subjected to burning treatment. While on the other hand, water is recovered into a storage tank and, after repeating use, purified by passing through an ion exchange resin-packed column and decontaminated to discharge. (Horiuchi, T.)
A Study on Decontamination Process Using Atmospheric Pressure Plasma
International Nuclear Information System (INIS)
Kim, Yong Soo; Jeon, Sang Hwan; Jin, Dong Sik; Park, Dong Min
2010-05-01
Radioactive decontamination process using atmospheric pressure plasma which can be operated parallel with low vacuum cold plasma processing is studied. Two types of cold plasma torches were designed and manufactured. One of them is the cylindrical type applicable to the treatment of three-dimensional surfaces. The other is the rectangular type for the treatment of flat and large surface areas. Ar palsam was unstable but using He as a carrier gas, discharge condition was improved. Besides filtering module using pre, medium, charcoal, and HEPA filter was designed and manufactured. More intensive study for developing filtering system will be followed. Atmospheric pressure plasma decontamination process can be used to the equipment and facility wall decontamination
International Nuclear Information System (INIS)
LaFrate, P.J. Jr.; Stout, D.S.; Elliott, J.W.
1996-01-01
The Los Alamos National Laboratory (LANL) Decommissioning Project has decontaminated, demolished, and decommissioned a process exhaust system, two filter plenum buildings, and a firescreen plenum structure at Technical Area 21 (TA-2 1). The project began in August 1995 and was completed in January 1996. These high-efficiency particulate air (HEPA) filter plenums and associated ventilation ductwork provided process exhaust to fume hoods and glove boxes in TA-21 Buildings 2 through 5 when these buildings were active plutonium and uranium processing and research facilities. This paper summarizes the history of TA-21 plutonium and uranium processing and research activities and provides a detailed discussion of integrated work process controls, characterize-as-you-go methodology, unique engineering controls, decontamination techniques, demolition methodology, waste minimization, and volume reduction. Also presented in detail are the challenges facing the LANL Decommissioning Project to safely and economically decontaminate and demolish surplus facilities and the unique solutions to tough problems. This paper also shows the effectiveness of the integrated work package concept to control work through all phases
International Nuclear Information System (INIS)
LaFrate, P.J. Jr.; Stout, D.S.; Elliott, J.W.
1996-01-01
The Los Alamos National Laboratory (LANL) Decommissioning Project has decontaminated, demolished, and decommissioned a process exhaust system, two filter plenum buildings, and a firescreen plenum structure at Technical Area 21 (TA-21). The project began in August 1995 and was completed in January 1996. These high-efficiency particulate air (HEPA) filter plenums and associated ventilation ductwork provided process exhaust to fume hoods and glove boxes in TA-21 Buildings 2 through 5 when these buildings were active plutonium and uranium processing and research facilities. This paper summarizes the history of TA-21 plutonium and uranium processing and research activities and provides a detailed discussion of integrated work process controls, characterize-as-you-go methodology, unique engineering controls, decontamination techniques, demolition methodology, waste minimization, and volume reduction. Also presented in detail are the challenges facing the LANL Decommissioning Project to safely and economically decontaminate and demolish surplus facilities and the unique solutions to tough problems. This paper also shows the effectiveness of the integrated work package concept to control work through all phases
Advance in radioactive decontamination
International Nuclear Information System (INIS)
Basteris M, J. A.; Farrera V, R.
2010-09-01
The objective of the present work was to determine if the application of the Na hypochlorite has some utility in the radioactive decontamination, in comparison with the water, detergent and alcohol. Several methods were compared for decontaminate the iodine 131 and technetium 99, the work table and the skin it was carried out an initial count with the Geiger Muller. Later on, in a single occasion, the areas were washed with abundant water, alcohol, clothes detergent and sodium hypochlorite (used commercially as domestic bleacher) without diluting. Observing that the percentage in the decrease of the counted radioactivity by the Geiger Muller, decreased in the following way: It was demonstrated that the Na hypochlorite presents the highest index of radioactive decontamination with 100% of effectiveness. The Na hypochlorite is an excellent substance that can be used with effectiveness and efficiency like decontamination element in the accident cases of radioactive contamination in the clinical laboratories of nuclear medicine. (Author)
Steam Generator Group Project. Task 6. Channel head decontamination
International Nuclear Information System (INIS)
Allen, R.P.; Clark, R.L.; Reece, W.D.
1984-08-01
The Steam Generator Group Project utilizes a retired-from-service pressurized-water-reactor steam generator as a test bed and source of specimens for research. An important preparatory step to primary side research activities was reduction of the radiation field in the steam generator channel head. This task report describes the channel head decontamination activities. Though not a programmatic research objective it was judged beneficial to explore the use of dilute reagent chemical decontamination techniques. These techniques presented potential for reduced personnel exposure and reduced secondary radwaste generation, over currently used abrasive blasting techniques. Two techniques with extensive laboratory research and vendors prepared to offer commercial application were tested, one on either side of the channel head. As indicated in the report, both techniques accomplished similar decontamination objectives. Neither technique damaged the generator channel head or tubing materials, as applied. This report provides details of the decontamination operations. Application system and operating conditions are described
Chemical decontamination of reactor components
International Nuclear Information System (INIS)
Riess, R.; Berthold, H.O.
1977-08-01
A solution for the decontamination of reactor components of the primary system was developed. This solution is a modification of the APAC- (Alkaline Permanganate Ammonium Citrate) system described in the literature. The most important advantage of the present solution over the APAC-method is that it does not induce any selective corrosion attack on materials like stainless steel (austenitic), Inconel 600 and Incoloy 800. (orig.) [de
Mishra, Rupesh K; Martín, Aida; Nakagawa, Tatsuo; Barfidokht, Abbas; Lu, Xialong; Sempionatto, Juliane R; Lyu, Kay Mengjia; Karajic, Aleksandar; Musameh, Mustafa M; Kyratzis, Ilias L; Wang, Joseph
2018-03-15
Flexible epidermal tattoo and textile-based electrochemical biosensors have been developed for vapor-phase detection of organophosphorus (OP) nerve agents. These new wearable sensors, based on stretchable organophosphorus hydrolase (OPH) enzyme electrodes, are coupled with a fully integrated conformal flexible electronic interface that offers rapid and selective square-wave voltammetric detection of OP vapor threats and wireless data transmission to a mobile device. The epidermal tattoo and textile sensors display a good reproducibility (with RSD of 2.5% and 4.2%, respectively), along with good discrimination against potential interferences and linearity over the 90-300mg/L range, with a sensitivity of 10.7µA∙cm 3 ∙mg -1 (R 2 = 0.983) and detection limit of 12mg/L in terms of OP air density. Stress-enduring inks, used for printing the electrode transducers, ensure resilience against mechanical deformations associated with textile and skin-based on-body sensing operations. Theoretical simulations are used to estimate the OP air density over the sensor surface. These fully integrated wearable wireless tattoo and textile-based nerve-agent vapor biosensor systems offer considerable promise for rapid warning regarding personal exposure to OP nerve-agent vapors in variety of decentralized security applications. Copyright © 2017 Elsevier B.V. All rights reserved.
CPP-603 Chloride Removal System Decontamination and Decommissioning
International Nuclear Information System (INIS)
Moser, C.L.
1993-02-01
The CPP-603 (annex) Chloride Removal System (CRS) Decontamination and Decommissioning (D ampersand D) Project is described in this report. The CRS was used for removing Chloride ions and other contaminants that were suspended in the waters of the underwater fuel storage basins in the CPP-603 Fuel Receiving and Storage Facility (FRSF) from 1975 to 1981. The Environmental Checklist and related documents, facility characterization, decision analysis', and D ampersand D plans' were prepared in 1991. Physical D ampersand D activities were begun in mid summer of 1992 and were completed by the end of November 1992. All process equipment and electrical equipment were removed from the annex following accepted asbestos and radiological contamination removal practices. The D ampersand D activities were performed in a manner such that no radiological health or safety hazard to the public or to personnel at the Idaho National Engineering Laboratory (INEL) occurred
Soil decontamination criteria report, November 1980
International Nuclear Information System (INIS)
Riordan, G.A.
1980-01-01
A program to access the extent of transuranic soil contamination at DOE sites and to develop methods for their decontamination is underway at Rocky Flats. As part of this program, acceptable soil contamination levels for plutonium proposed by a number of authorities over the past couple of decades were reviewed. From this review, goals for soil decontamination work are proposed. These goals, which relate to the disposition of the products of a decontamination process, are summarized as follows (dpm/g will refer to disintegrations per minute of transuranic nuclides per gram of soil): soil fractions having less than 30 dpm can be disposed of as surface soil with unrestricted usage. Fine soil fractions (less than 100 μm) that have less than 500 dpm and coarse soil fractions that have less than 1000 dpm can be disposed of as subsurface soil as long as usage is controlled to ensure compliance with EPA dosage guidance. Soil concentrates that have an activity greater than the above values but less than 22,000 dpm should be interred in an approved, low level waste burial site. Soil concentrates that are greater than 22,000 dpm should be stored as retrievable waste. Changes in the technical and legal areas of soil decontamination are rapid. Permissible soil decontamination levels will change as will decontamination technology and the ability to monitor the effectiveness of the decontamination processes. As a result, annual updates of decontamination criteria, goals, and monitoring are expected
75 FR 65151 - Marine Vapor Control Systems
2010-10-21
... Classification UFL Upper flammable limit USCG U.S. Coast Guard VCS Vapor control system VOC Volatile organic... transfer substance to new Subpart P, beginning with 33 CFR 154.2000, to facilitate the substantive changes... that guidance. Limit requirements for flame arresters or flame screens to the flammable, combustible...
Gas phase decontamination of gaseous diffusion process equipment
International Nuclear Information System (INIS)
Bundy, R.D.; Munday, E.B.; Simmons, D.W.; Neiswander, D.W.
1994-01-01
D ampersand D of the process facilities at the gaseous diffusion plants (GDPs) will be an enormous task. The EBASCO estimate places the cost of D ampersand D of the GDP at the K-25 Site at approximately $7.5 billion. Of this sum, nearly $4 billion is associated with the construction and operation of decontamination facilities and the dismantlement and transport of contaminated process equipment to these facilities. In situ long-term low-temperature (LTLT) gas phase decontamination is being developed and demonstrated at the K-25 site as a technology that has the potential to substantially lower these costs while reducing criticality and safeguards concerns and worker exposure to hazardous and radioactive materials. The objective of gas phase decontamination is to employ a gaseous reagent to fluorinate nonvolatile uranium deposits to form volatile LJF6, which can be recovered by chemical trapping or freezing. The LTLT process permits the decontamination of the inside of gas-tight GDP process equipment at room temperature by substituting a long exposure to subatmospheric C1F for higher reaction rates at higher temperatures. This paper outlines the concept for applying LTLT gas phase decontamination, reports encouraging laboratory experiments, and presents the status of the design of a prototype mobile system. Plans for demonstrating the LTLT process on full-size gaseous diffusion equipment are also outlined briefly
Koff, Matthew D; Brown, Jeremiah R; Marshall, Emily J; O'Malley, A James; Jensen, Jens T; Heard, Stephen O; Longtine, Karen; O'Neill, Melissa; Longtine, Jaclyn; Houston, Donna; Robison, Cindy; Moulton, Eric; Patel, Hetal M; Loftus, Randy W
2016-08-01
BACKGROUND Healthcare provider hands are an important source of intraoperative bacterial transmission events associated with postoperative infection development. OBJECTIVE To explore the efficacy of a novel hand hygiene improvement system leveraging provider proximity and individual and group performance feedback in reducing 30-day postoperative healthcare-associated infections via increased provider hourly hand decontamination events. DESIGN Randomized, prospective study. SETTING Dartmouth-Hitchcock Medical Center in New Hampshire and UMass Memorial Medical Center in Massachusetts. PATIENTS Patients undergoing surgery. METHODS Operating room environments were randomly assigned to usual intraoperative hand hygiene or to a personalized, body-worn hand hygiene system. Anesthesia and circulating nurse provider hourly hand decontamination events were continuously monitored and reported. All patients were followed prospectively for the development of 30-day postoperative healthcare-associated infections. RESULTS A total of 3,256 operating room environments and patients (1,620 control and 1,636 treatment) were enrolled. The mean (SD) provider hand decontamination event rate achieved was 4.3 (2.9) events per hour, an approximate 8-fold increase in hand decontamination events above that of conventional wall-mounted devices (0.57 events/hour); Phand hygiene system was not associated with a reduction in healthcare-associated infections (odds ratio, 1.07 [95% CI, 0.82-1.40], P=.626). CONCLUSIONS The hand hygiene system evaluated in this study increased the frequency of hand decontamination events without reducing 30-day postoperative healthcare-associated infections. Future work is indicated to optimize the efficacy of this hand hygiene improvement strategy. Infect Control Hosp Epidemiol 2016;37:888-895.
Electrochemical decontamination of metallic surfaces by means of a movable electrode
International Nuclear Information System (INIS)
Mihai, F.; Nicu, M.; Cazan, L.; Turcanu, C.
1998-01-01
Electrochemical decontamination can be considered to be a decontamination assisted by an electrochemical field. The method is applied to the metallic surface decontamination for contaminants of any physico-chemical nature. The physico-chemical phenomenon that is the basis for the electrochemical methods is the anodic layer dissolution. By dissolution of the superficial layer any radioactive contaminant on the surface or entrapped within the surface oxide is eliminated. Electrochemical decontamination, also known as electropolishing, involves the use of the object to be cleaned as an anode in an electrochemical cell. The passage of current results in anodic dissolution of the surface material. Generally, there are many methods of application for electropolishing. The most common method is immersing the object to be decontaminated in a tank filled with a suitable electrolyte. The electrochemical method with movable electrode involves the use of 'in situ' mobile devices that are able to electropolish punctual surfaces in places difficult to access. The advantages are the simplicity of the setup, short times of application and reduced waste volumes. Phosphoric and sulphuric acid mixture is used as the electrolyte in electropolishing because of its stability, safety and applicability to a variety of alloy systems. The method was applied to decontaminate carbon steel, aluminium and copper. Used contaminants are mixtures of 60 Co and 134 Cs; 60 Co and 65 Zn; 60 Co, 65 Zn and 134 Cs. After preparation, the samples were kept in laboratory conditions about one month, to simulate real conditions and to let the chemical reactions between contaminant and sample material constitution to complete. To calculate decontamination factor characteristic for each studied decontamination method the following radiometric measurements are necessary: - activity measurement after radioisotope solution contamination representing initial activity Λ in ; - activity measurement after
Decontamination of polyvinylchloride- and rubber type flooring
International Nuclear Information System (INIS)
Kunze, S.
1975-01-01
These types, fabricated by mixing of the basic components, showed no relation between content of fillers and decontamination results. Decontamination results are partly poorer, if the flooring contains a high concentration of the filler, especially if the latter consists mainly of hydrophilic materials. The coloring of the floorings seems to have no influence on the decontamination but floorings with clearly separated patterns can not be recommended for nuclear facilities. Fabricated by chemical reactions between polymeres, vulcanization materials and fillers, the decontamination results depend definitely from the proper choice of the filler. Flooring types, containing lampblack, graphite, kaoline, barium sulfate and titanium oxide are easy to decontamine. Again, increasing contents of hydrophilic filler cause a fall off in the decontamination results. (orig.) [de
Polymeric compositions for “dry” decontamination of NPP equipment and premises
International Nuclear Information System (INIS)
Voronik, N.I.; Toropova, V.V.
2015-01-01
In JIPNR – “Sosny” NASB developed decontaminating polymeric compositions based on binder – polyvinyl alcohol solution with active additives such as nitric and borohydrofluoric acids, 1-hydroxyethylidene diphosphonic acid and its salts, detergents and fillers - natural tripoli; tripoli modified by ferrocyanides of nickel and copper; pulverized dolomite modified by manganese oxides, ferrocyanides of nickel and copper; clinoptilolite modified by iron chlorides (III) and calcium sodium phosphate and potassium ferrocyanide; hydrolytic lignin. It is shown that the developed decontaminating polymeric compositions (pastes) possess high decontaminating capacity (FD 102 – 103) and low adhesion to the surfaces of stainless and carbon steels, including painted, plastic, self-leveling floors, teflon-surface. Prolonged leaching method allowed determine the chemical resistance of “dry” decontamination wastes, strength of "1"3"7Cs and "6"0Co fixations in wastes obtained in result of using new decontamination pastes [ru
International Nuclear Information System (INIS)
Soo, P.; Adams, J.W.; Kempf, C.R.
1987-01-01
During a typical decontamination event, ion-exchange resin beds are used to remove corrosion products (radioactive and nonradioactive) and excess decontamination reagents from waste streams. The spent resins may be solidified in a binder, such as cement, or sealed in a high-integrity container (HIC) in order to meet waste stability requirements specified by the Nuclear Regulatory Commission. Lack of stability of low-level waste in a shallow land burial trench may lead to trench subsidence, enhanced water infiltration and waste leaching, which would result in accelerated transport of radionuclides and the complexing agents used for decontamination. The current program is directed at investigating safety problems associated with the handling, solidification and containerization of decontamination resin wastes. The three tasks currently underway include freeze-thaw cycling of cementitious and vinyl ester-styrene forms to determine if mechanical integrity is compromised, a study of the corrosion of container materials by spent decontamination waste resins, and investigations of resin degradation mechanisms
Ultrahigh temperature vapor core reactor-MHD system for space nuclear electric power
Maya, Isaac; Anghaie, Samim; Diaz, Nils J.; Dugan, Edward T.
1991-01-01
The conceptual design of a nuclear space power system based on the ultrahigh temperature vapor core reactor with MHD energy conversion is presented. This UF4 fueled gas core cavity reactor operates at 4000 K maximum core temperature and 40 atm. Materials experiments, conducted with UF4 up to 2200 K, demonstrate acceptable compatibility with tungsten-molybdenum-, and carbon-based materials. The supporting nuclear, heat transfer, fluid flow and MHD analysis, and fissioning plasma physics experiments are also discussed.
Contamination and decontamination of skin
International Nuclear Information System (INIS)
Severa, J.; Knajfl, J.
1983-01-01
In external contamination the beta radiation dose is the prevalent component of the total dose absorbed by the skin. There exist four types of radionUclide bonds to the skin: mechanical retention of solid particles or solution on the surface and in the pores, physical adsorption of nondissociated molecules or colloids, the ion exchange effect, and chemisorption. Radionuclides then penetrate the skin by transfollicular transfer. The total amount of radioactive substances absorbed into the skin depends on the condition of the skin. Skin is decontaminated by washing with lukewarm water and soap or with special decontamination solutions. The most widely used components of decontamination solutions are detergents, chelaton, sodium hexametaphosphate, oxalic acid, citric acid. The main principles of the decontamination of persons are given. (M.D.)
International Nuclear Information System (INIS)
Minehara, Eisuke
2010-01-01
We recently have performed the feasibility studies to develop laser cleaners utilizing several laser oscillator and amplifier systems like femto-second free-electron lasers, water-jet guided lasers, Q-switched YAG lasers, fiber lasers. Whenever we used to clean the RI-contaminated surface using the lasers, we should focus enough laser power in the surface to evaporate instantly without melting. Therefore, as the contaminated being deeply located into the surface could be removed using any one set of the lasers, we found that every trial of laser cleaning could remove very well the RI contamination being located deeply. Our cold decontamination test using a model sample being Cobalt plated successfully has been performed to show a very high decontamination factor. In order to develop an usable laser cleaner, we plan to develop the prototype laser cleaner next year. (author)
Long-term decontamination engineering study. Volume 1
Energy Technology Data Exchange (ETDEWEB)
Geuther, W.J.
1995-04-03
This report was prepared by Westinghouse Hanford Company (WHC) with technical and cost estimating support from Pacific Northwest Laboratories (PNL) and Parsons Environmental Services, Inc. (Parsons). This engineering study evaluates the requirements and alternatives for decontamination/treatment of contaminated equipment at the Hanford Site. The purpose of this study is to determine the decontamination/treatment strategy that best supports the Hanford Site environmental restoration mission. It describes the potential waste streams requiring treatment or decontamination, develops the alternatives under consideration establishes the criteria for comparison, evaluates the alternatives, and draws conclusions (i.e., the optimum strategy for decontamination). Although two primary alternatives are discussed, this study does identify other alternatives that may warrant additional study. hanford Site solid waste management program activities include storage, special processing, decontamination/treatment, and disposal facilities. This study focuses on the decontamination/treatment processes (e.g., waste decontamination, size reduction, immobilization, and packaging) that support the environmental restoration mission at the Hanford Site.
Long-term decontamination engineering study. Volume 1
International Nuclear Information System (INIS)
Geuther, W.J.
1995-01-01
This report was prepared by Westinghouse Hanford Company (WHC) with technical and cost estimating support from Pacific Northwest Laboratories (PNL) and Parsons Environmental Services, Inc. (Parsons). This engineering study evaluates the requirements and alternatives for decontamination/treatment of contaminated equipment at the Hanford Site. The purpose of this study is to determine the decontamination/treatment strategy that best supports the Hanford Site environmental restoration mission. It describes the potential waste streams requiring treatment or decontamination, develops the alternatives under consideration establishes the criteria for comparison, evaluates the alternatives, and draws conclusions (i.e., the optimum strategy for decontamination). Although two primary alternatives are discussed, this study does identify other alternatives that may warrant additional study. hanford Site solid waste management program activities include storage, special processing, decontamination/treatment, and disposal facilities. This study focuses on the decontamination/treatment processes (e.g., waste decontamination, size reduction, immobilization, and packaging) that support the environmental restoration mission at the Hanford Site
EDF/CIDEN - ONECTRA: PWR decontamination
International Nuclear Information System (INIS)
Fayolle, P.; Orcel, H.; Wertz, L.
2010-01-01
In the context of PWR circuit renewal (expected in 2011) and their decontamination, an analysis of data coming from cartography and on site decontamination measurements as well as from premise modelling by means of the PANTHERE radioprotection code, is presented. Several French PWRs have been studied. After a presentation of code principles and operation, the authors discuss the radiological context of a workstation, and give an assessment of the annual dose associated with maintenance operations with or without decontamination
TMI-2 containment decontamination plans
International Nuclear Information System (INIS)
McDougall, F.
1980-01-01
Because of other priorities such as reentry, purging, and recovery, containment decontamination is only in the preliminary planning stages. This paper summarizes the study with emphasis on the remote decontamination techniques
Chemically reducing decontamination method for radioactive metal
International Nuclear Information System (INIS)
Tanaka, Akio; Onuma, Tsutomu; Sato, Hitoshi.
1994-01-01
The present invention concerns a decontamination method of electrolytically reducing radioactive metal wastes, then chemically dissolving the surface thereof with a strong acid decontaminating solution. This method utilizes dissolving characteristics of stainless steels in the strong acid solution. That is, in the electrolytic reduction operation, a portion of the metal wastes is brought into contact with a strong acid decontaminating solution, and voltage and current are applied to the portion and keep it for a long period of time so as to make the potential of the immersed portion of the metal wastes to an active soluble region. Then, the electrolytic reduction operation is stopped, and the metal wastes are entirely immersed in the decontaminating solution to decontaminate by chemical dissolution. As the decontaminating solution, strong acid such as sulfuric acid, nitric acid is used. Since DC current power source capacity required for causing reaction in the active soluble region can be decreased, the decontamination facility can be minimized and simplified, and necessary electric power can be saved even upon decontamination of radioactive metal wastes made of stainless steels and having a great area. Further, chemical dissolution can be conducted without adding an expensive oxidizing agent. (N.H.)
Modeling Two-Phase Flow and Vapor Cycles Using the Generalized Fluid System Simulation Program
Smith, Amanda D.; Majumdar, Alok K.
2017-01-01
This work presents three new applications for the general purpose fluid network solver code GFSSP developed at NASA's Marshall Space Flight Center: (1) cooling tower, (2) vapor-compression refrigeration system, and (3) vapor-expansion power generation system. These systems are widely used across engineering disciplines in a variety of energy systems, and these models expand the capabilities and the use of GFSSP to include fluids and features that are not part of its present set of provided examples. GFSSP provides pressure, temperature, and species concentrations at designated locations, or nodes, within a fluid network based on a finite volume formulation of thermodynamics and conservation laws. This paper describes the theoretical basis for the construction of the models, their implementation in the current GFSSP modeling system, and a brief evaluation of the usefulness of the model results, as well as their applicability toward a broader spectrum of analytical problems in both university teaching and engineering research.
Airborne differential absorption lidar system for water vapor investigations
Browell, E. V.; Carter, A. F.; Wilkerson, T. D.
1981-01-01
Range-resolved water vapor measurements using the differential-absorption lidar (DIAL) technique is described in detail. The system uses two independently tunable optically pumped lasers operating in the near infrared with laser pulses of less than 100 microseconds separation, to minimize concentration errors caused by atmospheric scattering. Water vapor concentration profiles are calculated for each measurement by a minicomputer, in real time. The work is needed in the study of atmospheric motion and thermodynamics as well as in forestry and agriculture problems.
[Decontamination of chemical warfare agents by photocatalysis].
Hirakawa, Tsutomu; Mera, Nobuaki; Sano, Taizo; Negishi, Nobuaki; Takeuchi, Koji
2009-01-01
Photocatalysis has been widely applied to solar-energy conversion and environmental purification. Photocatalyst, typically titanium dioxide (TiO(2)), produces active oxygen species under irradiation of ultraviolet light, and can decompose not only conventional pollutants but also different types of hazardous substances at mild conditions. We have recently started the study of photocatalytic decontamination of chemical warfare agents (CWAs) under collaboration with the National Research Institute of Police Science. This article reviews environmental applications of semiconductor photocatalysis, decontamination methods for CWAs, and previous photocatalytic studies applied to CWA degradation, together with some of our results obtained with CWAs and their simulant compounds. The data indicate that photocatalysis, which may not always give a striking power, certainly helps detoxification of such hazardous compounds. Unfortunately, there are not enough data obtained with real CWAs due to the difficulty in handling. We will add more scientific data using CWAs in the near future to develop useful decontamination systems that can reduce the damage caused by possible terrorism.
Decontamination of lead by fusion (1962)
International Nuclear Information System (INIS)
Boutot, P.; Giachetto, L.; Capitaine, A.
1962-01-01
Various attempts to decontaminate using mechanical and chemical methods having given questionable results, a fusion method has been developed. The apparatus consists of a propane-heated oven fitted with a steel crucible of 1 400 kg capacity, with two ventilation systems, and with a vacuum gauge for preventing the diffusion of toxic gases. There are three operational controls : 1. On the samples taken before during and after the operation, 2. On the plugs taken from the ingots, 3. On the ingot itself. The continuous sanitary control is done by a radioactive aerosol recorder and by periodic sampling. This decontamination process will be improved, especially as far as the productivity and the safety precautions are concerned. (authors) [fr
Decontamination Technology Development for Nuclear Research Facilities
International Nuclear Information System (INIS)
Choi, W. K.; Jung, C. H.; Oh, W. Z.
2007-06-01
The originative CO 2 pellet blasting equipment was developed by improving additional components such as feed screw, idle roller and air-lock feeder to clear up the problems of freezing and discontinuity of blasting and by adopting pneumatically operated vacuum suction head and vacuum cup to prevent recontamination by collecting contaminant particulates simultaneously with the decontamination. The optimum decontamination process was established according to the kind of materials such as metal, concrete and plastic and the type of contaminants such as particulate, fixed chemical compound and oil. An excellent decontamination performances were verified by means of the lab-scale hot test with radioactive specimen and the technology demonstration in IMEF hot cell. The PFC dry decontamination equipment applicable to the surface contaminated with high radioactive particulate was developed. This equipment consists of the unit processes such as spray, collection, filtration and dry distillation designed originatively applicable to inside of dry hot cell. Through the demonstration of PFC spray decontamination process in IMEF hot cell, we secured on-site applicability and the decontamination efficiency more than 90 %. We investigated the characteristics of dismantled metal waste melting and the radionuclide(Co, Cs, U) distribution into ingot and slag by melting decontamination experiments using electric arc melter. We obtained the decontamination factors greater than 100 for Cs and of 10∼100 for uranium. The pilot scale(200 kg/batch) demonstration for melting decontamination was carried out successfully using high temperature melting facility at KAERI. The volume reduction factor of 1/7 and the economical feasibility of the melting decontamination were verified.
Optimized laser system for decontamination of painted surfaces
International Nuclear Information System (INIS)
Champonnois, F.; Lascoutouna, C.; Long, H.; Thro, P.Y.; Mauchien, P.
2010-01-01
Laser systems have long been seen as potentially very interesting for removing contamination from surfaces. The main expected advantages are the possibility of remote process and the absence of secondary waste. However these systems were unable to find their way to an industrial deployment due to the lack of reliability of the laser and the difficulty to satisfactory collect the (contaminated) ablated matter. In this contribution we report on a compact, reliable and efficient laser decontaminating system called ASPILASERO. It is adapted to the constraints bound to a nuclear environment. It takes advantages of the recent progress made by the fibre lasers which have now a lifetime longer than 20000 hours without maintenance. The collecting system collects all the removed matter (gases and aerosols) on nuclear grade filters. The fully automated system has been successfully tested on a vertical wall of a stopped nuclear installation. It has demonstrated an efficiency of 1 m 2 /hr which is in the same order of other classical techniques but with a much lower quantity of waste and the ability to work continuously without human intervention. Measurements performed after the laser treatment have shown that the contamination was completely removed by removing the paint and that this contamination was not re-deposited elsewhere on the wall. The system will also be used in highly contaminated hot cells to decrease the radiation and allow maintenance or refurbishing in safe working conditions. (authors)
RSDL decontamination of human skin contaminated with the nerve agent VX.
Thors, L; Lindberg, S; Johansson, S; Koch, B; Koch, M; Hägglund, L; Bucht, A
2017-03-05
Dermal exposure to low volatile organophosphorus compounds (OPC) may lead to penetration through the skin and uptake in the blood circulation. Skin decontamination of toxic OPCs, such as pesticides and chemical warfare nerve agents, might therefore be crucial for mitigating the systemic toxicity following dermal exposure. Reactive skin decontamination lotion (RSDL) has been shown to reduce toxic effects in animals dermally exposed to the nerve agent VX. In the present study, an in vitro flow-through diffusion cell was utilized to evaluate the efficacy of RSDL for decontamination of VX exposed to human epidermis. In particular, the impact of timing in the initiation of decontamination and agent dilution in water was studied. The impact of the lipophilic properties of VX in the RSDL decontamination was additionally addressed by comparing chemical degradation in RSDL and decontamination efficacy between the VX and the hydrophilic OPC triethyl phosphonoacetate (TEPA). The epidermal membrane was exposed to 20, 75 or 90% OPC diluted in deionized water and the decontamination was initiated 5, 10, 30, 60 or 120min post-exposure. Early decontamination of VX with RSDL, initiated 5-10min after skin exposure, was very effective. Delayed decontamination initiated 30-60min post-exposure was less effective but still the amount of penetrated agent was significantly reduced, while further delayed start of decontamination to 120min resulted in very low efficacy. Comparing RSDL decontamination of VX with that of TEPA showed that the decontamination efficacy at high agent concentrations was higher for VX. The degradation mechanism of VX and TEPA during decontamination was dissected by 31 P NMR spectroscopy of the OPCs following reactions with RSDL and its three nucleophile components. The degradation rate was clearly associated with the high pH of the specific solution investigated; i.e. increased pH resulted in a more rapid degradation. In addition, the solubility of the OPC in RSDL
MERCURY CONTAMINATED MATERIAL DECONTAMINATION METHODS: INVESTIGATION AND ASSESSMENT
Energy Technology Data Exchange (ETDEWEB)
M.A. Ebadian, Ph.D.
2001-01-01
Over the years mercury has been recognized as having serious impacts on human health and the environment. This recognition has led to numerous studies that deal with the properties of various mercury forms, the development of methods to quantify and speciate the forms, fate and transport, toxicology studies, and the development of site remediation and decontamination technologies. This report reviews several critical areas that will be used in developing technologies for cleaning mercury from mercury-contaminated surfaces of metals and porous materials found in many DOE facilities. The technologies used for decontamination of water and mixed wastes (solid) are specifically discussed. Many technologies that have recently appeared in the literature are included in the report. Current surface decontamination processes have been reviewed, and the limitations of these technologies for mercury decontamination are discussed. Based on the currently available technologies and the processes published recently in the literature, several processes, including strippable coatings, chemical cleaning with iodine/iodide lixiviant, chemisorbing surface wipes with forager sponge and grafted cotton, and surface/pore fixation through amalgamation or stabilization, have been identified as potential techniques for decontamination of mercury-contaminated metal and porous surfaces. Their potential merits and applicability are discussed. Finally, two processes, strippable coatings and chemical cleaning with iodine/iodide lixiviant, were experimentally investigated in Phase II of this project.
International Nuclear Information System (INIS)
Oh, Won Zin; Jung, Ki Jung; Lee, Byung Jik
1997-01-01
This paper describes the introduction to research reactor decommissioning plan at KAERI, the background of technology development and demonstration, and the current status of the system decontamination technology for TRIGA reactors, concrete decontamination and dust treatment technologies, wall ranging robot and graphic simulation of dismantling processes, soil decontamination and restoration technology, recycling or reuse technologies for radioactive metallic wastes, and incineration technology demonstration for combustible wastes. 9 figs
Decontamination of burns contaminated with radioactive materials
International Nuclear Information System (INIS)
Vykouril, L.
1986-01-01
The suitability of various solutions for the decontamination of burnt skin and their efficiency were tested by experiments on rats. Tested was the decontamination of undisturbed skin, second degree skin burns and third degree skin burns. Decontamination solutions used included: distilled water, jodonal (an aqueous solution of iodine, ethoxylated nonylphenols, the copolymer of ethylene oxide with propylene oxide, and phosphoric acid) and a decontamination mixture of Sapon, Komplexon (trade names of detergents) and sodium hexametaphosphate. Decontamination efficiency was 68.4% for second degree burns and 47.1% for third degree burns. Most effective was the decontamination solution with an efficiency of 72%; the efficiency of jodonal was 67% and of water - 54%. Jodonal is the most suitable: in addition, it acts as a disinfectant and antiseptic. (M.D.)
Statistical sampling method for releasing decontaminated vehicles
International Nuclear Information System (INIS)
Lively, J.W.; Ware, J.A.
1996-01-01
Earth moving vehicles (e.g., dump trucks, belly dumps) commonly haul radiologically contaminated materials from a site being remediated to a disposal site. Traditionally, each vehicle must be surveyed before being released. The logistical difficulties of implementing the traditional approach on a large scale demand that an alternative be devised. A statistical method (MIL-STD-105E, open-quotes Sampling Procedures and Tables for Inspection by Attributesclose quotes) for assessing product quality from a continuous process was adapted to the vehicle decontamination process. This method produced a sampling scheme that automatically compensates and accommodates fluctuating batch sizes and changing conditions without the need to modify or rectify the sampling scheme in the field. Vehicles are randomly selected (sampled) upon completion of the decontamination process to be surveyed for residual radioactive surface contamination. The frequency of sampling is based on the expected number of vehicles passing through the decontamination process in a given period and the confidence level desired. This process has been successfully used for 1 year at the former uranium mill site in Monticello, Utah (a CERCLA regulated clean-up site). The method forces improvement in the quality of the decontamination process and results in a lower likelihood that vehicles exceeding the surface contamination standards are offered for survey. Implementation of this statistical sampling method on Monticello Projects has resulted in more efficient processing of vehicles through decontamination and radiological release, saved hundreds of hours of processing time, provided a high level of confidence that release limits are met, and improved the radiological cleanliness of vehicles leaving the controlled site
International Nuclear Information System (INIS)
Camargo, G.A.M.
1986-01-01
A mobile decontamination unit was developed to perform 'in situ' decontamination of tanks and pressure vessels belonging to the reactor auxiliary and ancillary systems. The whole system, including a control desk, is assembled in 6 trolleys which can be moved inside the plant, thus enabling component decontamination by injecting demineralized water at a pressure of approx. 50 bar and temperatures up to 90 0 , with or without chemical additives. Considering the versatility and easy handling demonstrated after extensive testing, this new system shall be used in Angra 2 and 3. (Author) [pt
Decontaminating method for radioactive contaminant
International Nuclear Information System (INIS)
Suzuki, Ken-ichi.
1994-01-01
After decontamination of radioactive contaminates with d-limonene, a radioactive material separating agent not compatible with liquid wastes caused by decontamination is added to the liquid wastes. Then after stirring, they are stood still to be separated into two phases, and the radioactive materials in the liquid waste phase caused by decontamination are transferred to the phase of the radioactive material separating agent. With such procedures, they can satisfactorily be separated into two phases of d-limonene and the radioactive material separating agent. Further, d-limonene remaining after the separation can be used again as a decontaminating agent for radioactive contaminates. Therefore, the amount of d-limonene to be used can be reduced, to lower the cost for cleaning, thereby enabling to reduce the amount of radioactive wastes formed. (T.M.)
Cao, Yachao; Elmahdy, Akram; Zhu, Hanjiang; Hui, Xiaoying; Maibach, Howard
2018-05-01
Six chemical warfare agent simulants (trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate) were studied in in vitro human skin to explore relationship between dermal penetration/absorption and the mechanisms of simulant partitioning between stratum corneum (SC) and water as well as between dermal decontamination gel (DDGel) and water. Both binding affinity to and decontamination of simulants using DDGel were studied. Partition coefficients of six simulants between SC and water (Log P SC/w ) and between DDGel and water (Log P DDGel/w ) were determined. Results showed that DDGel has a similar or higher binding affinity to each simulant compared to SC. The relationship between Log P octanol/water and Log P SC/w as well as between Log P octanol/water and Log P DDGel/w demonstrated that partition coefficient of simulants correlated to their lipophilicity or hydrophilicity. Decontamination efficiency results with DDGel for these simulants were consistent with binding affinity results. Amounts of percentage dose of chemicals in DDGel of trimethyl phosphate, dimethyl adipate, 2-chloroethyl methyl sulfide, diethyl adipate, chloroethyl phenyl sulfide and diethyl sebacate were determined to be 61.15, 85.67, 75.91, 53.53, 89.89 and 76.58, with corresponding amounts absorbed in skin of 0.96, 0.65, 1.68, 0.72, 0.57 and 1.38, respectively. In vitro skin decontamination experiments coupled with a dermal absorption study demonstrated that DDGel can efficiently remove chemicals from skin surface, back-extract from the SC, and significantly reduced chemical penetration into skin or systemic absorption for all six simulants tested. Therefore, DDGel offers a great potential as a NextGen skin Decon platform technology for both military and civilian use. Copyright © 2018 John Wiley & Sons, Ltd.
Energy Technology Data Exchange (ETDEWEB)
Dupin, L.
2011-04-15
This article gives an overview of what will have to be done on the site of Fukushima to decontaminate and to dismantle it. Based on the experience gained in Three Mile Island and in Chernobyl, experts foresee ten years of work within the reactor cores, thirty years around the plant, sixty years of decontamination within the no man's land area around the plant; and centuries as far as scattered spots are concerned more than hundred kilometres away from the plant. Three radionuclides must be surveyed, but with different half lives: iodine 131 (8 days), caesium 137 (30 years), and plutonium 239 (24000 years). The expertise of French companies (Areva, Assystem, Bouygues and Vinci) in reactor dismantling, dismantling procedure design, and public works (protection arch like in Chernobyl) is briefly evoked, as well as the French approach for post-accident management
Training of skin decontamination and its results
International Nuclear Information System (INIS)
Yasunaka, Hideo; Wadachi, Yoshiki.
1976-01-01
In the nuclear power and radioisotope handling facilities, one of the most important problems is a radioactive contamination on skin. Hand skin contamination occurs very often in the operation area and such surface contamination must be removed as soon as possible to prevent an internal contamination. From 1967 to 1975, training courses for skin decontamination had been held with total 536 of trainee based on the radiation protection manual at the Oarai Research Establishment of JAERI. In the training courses, fresh pig skin samples used instead of human skin were contaminated with 137 Cs, 131 I, 85 Sr, 60 Co, 144 Ce, 88 Y, 239 Pu, fission products and activated metal corrosion particles, respectively. These samples were washed practically by each trainee with the skin decontamination method recommended in the manual. Results obtained in the training showed that such training itself is a significant work and this skin decontamination method is an excellent first aid. (auth.)
Directory of Open Access Journals (Sweden)
Michael B. Sherman
2015-05-01
Full Text Available A unique biological safety level (BSL-3 cryo-electron microscopy facility with a 200 keV high-end cryo-electron microscope has been commissioned at the University of Texas Medical Branch (UTMB to study the structure of viruses and bacteria classified as select agents. We developed a microscope decontamination protocol based on chlorine dioxide gas with a continuous flow system. In this paper we report on testing digital camera sensors (both CCD and CMOS direct detector in a BSL-3 environment, and microscope performance after chlorine dioxide (ClO2 decontamination cycles.
Specific decontamination methods: water nozzle, cavitation erosion
International Nuclear Information System (INIS)
Boulitrop, D.; Gauchon, J.P.; Lecoffre, Y.
1984-05-01
The erosion and decontamination tests carried out in the framework of this study, allowed to specify the fields favourable to the use of the high pressure jet taking into account the determinant parameters that are the pressure and the target-nozzle distance. The previous spraying of gels with chemical reagents (sulfuric acid anf hydrazine) allows to get better decontamination factors. Then, the feasibility study of a decontamination method by cavitation erosion is presented. Gelled compounds for decontamination have been developed; their decontamination quality has been evaluated by comparative contamination tests in laboratory and decontamination tests of samples of materials used in nuclear industry; this last method is adapted to remote handling devices and produces a low quantity of secondary effluents, so it allows to clean high contaminated installation on the site without additional exposure of the personnel [fr
Pressure intelligent control strategy of Waste heat recovery system of converter vapors
Feng, Xugang; Wu, Zhiwei; Zhang, Jiayan; Qian, Hong
2013-01-01
The converter gas evaporative cooling system is mainly used for absorbing heat in the high temperature exhaust gas which produced by the oxygen blowing reaction. Vaporization cooling steam pressure control system of converter is a nonlinear, time-varying, lagging behind, close coupling of multivariable control object. This article based on the analysis of converter operation characteristics of evaporation cooling system, of vaporization in a production run of pipe pressure variation and disturbance factors.For the dynamic characteristics of the controlled objects,we have improved the conventional PID control scheme.In Oxygen blowing process, we make intelligent control by using fuzzy-PID cascade control method and adjusting the Lance,that it can realize the optimization of the boiler steam pressure control.By design simulation, results show that the design has a good control not only ensures drum steam pressure in the context of security, enabling efficient conversion of waste heat.And the converter of 1800 flue gas through pipes and cool and dust removal also can be cooled to about 800. Therefore the converter haze evaporative cooling system has achieved to the converter haze temperature decrease effect and enhanced to the coal gas returns-ratio.
Love, Adam H; Bailey, Christopher G; Hanna, M Leslie; Hok, Saphon; Vu, Alex K; Reutter, Dennis J; Raber, Ellen
2011-11-30
Bench-scale testing was used to evaluate the efficacy of four decontamination formulations on typical indoor surfaces following exposure to the liquid chemical warfare agents sarin (GB), soman (GD), sulfur mustard (HD), and VX. Residual surface contamination on coupons was periodically measured for up to 24h after applying one of four selected decontamination technologies [0.5% bleach solution with trisodium phosphate, Allen Vanguard Surface Decontamination Foam (SDF™), U.S. military Decon Green™, and Modec Inc. and EnviroFoam Technologies Sandia Decontamination Foam (DF-200)]. All decontamination technologies tested, except for the bleach solution, performed well on nonporous and nonpermeable glass and stainless-steel surfaces. However, chemical agent residual contamination typically remained on porous and permeable surfaces, especially for the more persistent agents, HD and VX. Solvent-based Decon Green™ performed better than aqueous-based bleach or foams on polymeric surfaces, possibly because the solvent is able to penetrate the polymer matrix. Bleach and foams out-performed Decon Green for penetrating the highly polar concrete surface. Results suggest that the different characteristics needed for an ideal and universal decontamination technology may be incompatible in a single formulation and a strategy for decontaminating a complex facility will require a range of technologies. Copyright © 2011 Elsevier B.V. All rights reserved.
New decontamination techniques generating a low volume of effluent
Energy Technology Data Exchange (ETDEWEB)
NONE
2002-07-01
This document presents some decontamination techniques, their principles, characteristics and advantages and provides references on the subject. Techniques as foam and spray foam decontamination, dry steam decontamination, electro-decontamination and gel decontamination are presented. A presentation of TRIADE, cleanup dismantling servicing, is also provided. (A.L.B.)
New decontamination techniques generating a low volume of effluent
International Nuclear Information System (INIS)
2002-01-01
This document presents some decontamination techniques, their principles, characteristics and advantages and provides references on the subject. Techniques as foam and spray foam decontamination, dry steam decontamination, electro-decontamination and gel decontamination are presented. A presentation of TRIADE, cleanup dismantling servicing, is also provided. (A.L.B.)
International Nuclear Information System (INIS)
Bicker, A.E.
1981-01-01
Among the several DOE sites that have been radiologically decontaminated under the auspices of the Nevada Operations Office are three whose physical characteristics are unique. These are the Tatum Dome Test Site (TDTS) near Hattiesburg, Mississippi; a location of mountainous terrain (Pahute Mesa) on the Nevada Test Site; and the GNOME site near Carlsbad, New Mexico. In each case the contamination, the terrain, and the climate conditions were different. This presentation includes a brief description of each site, the methods used to perform radiological surveys, the logistics required to support the decontamination (including health physics and sample analysis), and the specific techniques used to reduce or remove the contamination
Cleaning and decontamination: Experimental feedback from PHENIX
International Nuclear Information System (INIS)
Masse, F.; Rodriguez, G.
1997-01-01
After the first few years of operation of PHENIX, it proved necessary to clean, then decontaminate sodium-polluted components, particularly large components such as the intermediate heat exchangers (IHX) and the primary pumps (PP). Ibis document presents the evolution of the cleaning and decontamination processes used, and specifies the reasons for this evolution. As regards the cleaning, experimental feedback and a greater rigour with respect to the hydrogen hazard have resulted in a modification of the process. The new cleaning process used at present (since 1994) is described in greater detail in this document. The main steps are: cold CO 2 bubbling in water, followed by hot CO 2 bubbling, spraying phase, then drying for inspection before immersion. In order to optimize and validate the process, the cleaning and decontamination plant has been highly instrumented, which, in particular, has allowed confirmation of the contention that the major part of the sodium is eliminated during the bubbling phases. With respect to decontamination, the objective is to perfect an efficient process that allows both human intervention with no particular biological shield for repair or maintenance of the components, and requalification of the materials after the decontamination operation. Owing to the high operating temperature of Fast Breeder Reactor components (400 to 550 deg. C), the activated corrosion products deposited on the components melt into the metal. The decontamination process therefore consists in either dissolving the deposits on the surface, or dissolving a thickness of about less than ten micrometers of the base metal. The reference process for austenitic-type steels is the SPm process, which consists in immersing the component in a sulphuric-phosphoric bath (sulphuric acid and phosphoric acid) at a temperature of 60 deg. C for 6 hours. The problem linked to this process is the treatment of the effluents that are produced, particularly phosphate releases. A
Development of Nuclear Decontamination Technology Using Supercritical Fluid
Energy Technology Data Exchange (ETDEWEB)
Jung, Wonyoung; Park, Kwangheon; Park, Jihye; Lee, Donghee [Kyunghee Univ., Yongin (Korea, Republic of)
2014-05-15
Soil cleaning technologies that have been developed thus far increase treatment costs in contaminated soil recovery processes because they generate large amounts of secondary wastes. In this respect, this study is intended to develop soil decontamination methods using CO{sub 2}, which is a nontoxic, environmentally friendly substance, in order to fundamentally suppress the generation of secondary wastes from the decontamination process and to create high added values. In this study, to develop decontamination methods for uranium-contaminated soil using supercritical CO{sub 2}, a soil decontamination system using supercritical CO{sub 2} was constructed. In addition, the basic principle of supercritical CO{sub 2} decontamination using a TBP-HNO3 complex was explained. According to the results of the study, sea-sand samples having the same degree of contamination showed different results of decontamination according to the quantities of the TBP-HNO3 complex used as an extraction agent, which resulted in high extraction rates. Thus far, a most widely used method of extracting uranium has been the dissolving of uranium in acids. However, this method has the large adverse effect of generating strong acidic wastes that cannot be easily treated. On the other hand, supercritical CO{sub 2} requires critical conditions that are no more difficult to meet than those of other supercritical fluids, since its density can be changed from a very low state close to that of an ideal gas to a high state close to that of liquids. The critical gas conditions are a pressure of 71 bar and a temperature of 31 .deg. C, both of which are inexpensive to achieve. Moreover, CO{sub 2} is a solvent that is not harmful to the human body and few effects on environmental pollution. Therefore, nontoxic and environment friendly processes can be developed using supercritical CO{sub 2}. Supercritical CO{sub 2}'s advantages over prevailing methods suggest its potential for developing innovative
Development of Nuclear Decontamination Technology Using Supercritical Fluid
International Nuclear Information System (INIS)
Jung, Wonyoung; Park, Kwangheon; Park, Jihye; Lee, Donghee
2014-01-01
Soil cleaning technologies that have been developed thus far increase treatment costs in contaminated soil recovery processes because they generate large amounts of secondary wastes. In this respect, this study is intended to develop soil decontamination methods using CO 2 , which is a nontoxic, environmentally friendly substance, in order to fundamentally suppress the generation of secondary wastes from the decontamination process and to create high added values. In this study, to develop decontamination methods for uranium-contaminated soil using supercritical CO 2 , a soil decontamination system using supercritical CO 2 was constructed. In addition, the basic principle of supercritical CO 2 decontamination using a TBP-HNO3 complex was explained. According to the results of the study, sea-sand samples having the same degree of contamination showed different results of decontamination according to the quantities of the TBP-HNO3 complex used as an extraction agent, which resulted in high extraction rates. Thus far, a most widely used method of extracting uranium has been the dissolving of uranium in acids. However, this method has the large adverse effect of generating strong acidic wastes that cannot be easily treated. On the other hand, supercritical CO 2 requires critical conditions that are no more difficult to meet than those of other supercritical fluids, since its density can be changed from a very low state close to that of an ideal gas to a high state close to that of liquids. The critical gas conditions are a pressure of 71 bar and a temperature of 31 .deg. C, both of which are inexpensive to achieve. Moreover, CO 2 is a solvent that is not harmful to the human body and few effects on environmental pollution. Therefore, nontoxic and environment friendly processes can be developed using supercritical CO 2 . Supercritical CO 2 's advantages over prevailing methods suggest its potential for developing innovative decontamination methods, as demonstrated
International Nuclear Information System (INIS)
Gray, R.A.; Williams, P.L.; Dubbins, P.A.; Jenks, P.J.
2012-01-01
Aim: To determine the national practice of transvaginal ultrasound (TVUS) probe decontamination in English hospitals and to develop recommendations for guidance. Materials and methods: A literature review was undertaken to clarify best practice and evaluate methods of decontamination of TVUS probes. A questionnaire was developed to ascertain TVUS probe decontamination programmes in current use within English hospitals. This was sent to ultrasound leads of 100 English hospitals; 68 hospitals responded. Results: There is a wide variation in TVUS probe decontamination across English hospitals. Although the majority of respondents (87%, 59/68) reported having clear and practical written guidelines for TVUS decontamination, the frequency, methods, and types of decontamination solutions utilized were widely variable and none meet the standards required to achieve high-level disinfection. Conclusion: While the decontamination of other endoluminal medical devices (e.g., flexible endoscopes) is well defined and regulated, the decontamination of TVUS probes has no such guidance. There appears to be incomplete understanding of the level of risk posed by TVUS probes, and in some cases, this has resulted in highly questionable practices regarding TVUS hygiene. There is an urgent need to develop evidence-based national guidance for TVUS probe decontamination.
Treatment of wastes arising from decontamination process using citric acid as a decontaminate agent
International Nuclear Information System (INIS)
Mierzwa, J.C.; Riella, H.G.; Carvalho, E.U. de
1993-01-01
Wastes arising from equipment decontamination processes from nuclear fuel cycle facilities at Coordenacao de Projetos Especiais - Comissao Nacional de Energia Nuclear, Sao Paulo (COPESP-CNEN/SP) has been studied after using citric acid as a decontaminate agent. Precipitation of uranium and metallic impurities resulted from use of sodium hydroxide or calcium oxide plus a flocculation agent. The removal efficient of uranium was 95% and 99% for sodium hydroxide and calcium oxide respectively. The results shows that this process can be used to test wastes from decontamination processes which use citric acid. (B.C.A.). 03 refs, 08 figs, 04 tabs
DECONTAMINATION TECHNOLOGIES FOR FACILITY REUSE
International Nuclear Information System (INIS)
Bossart, Steven J.; Blair, Danielle M.
2003-01-01
As nuclear research and production facilities across the U.S. Department of Energy (DOE) nuclear weapons complex are slated for deactivation and decommissioning (D and D), there is a need to decontaminate some facilities for reuse for another mission or continued use for the same mission. Improved technologies available in the commercial sector and tested by the DOE can help solve the DOE's decontamination problems. Decontamination technologies include mechanical methods, such as shaving, scabbling, and blasting; application of chemicals; biological methods; and electrochemical techniques. Materials to be decontaminated are primarily concrete or metal. Concrete materials include walls, floors, ceilings, bio-shields, and fuel pools. Metallic materials include structural steel, valves, pipes, gloveboxes, reactors, and other equipment. Porous materials such as concrete can be contaminated throughout their structure, although contamination in concrete normally resides in the top quarter-inch below the surface. Metals are normally only contaminated on the surface. Contamination includes a variety of alpha, beta, and gamma-emitting radionuclides and can sometimes include heavy metals and organic contamination regulated by the Resource Conservation and Recovery Act (RCRA). This paper describes several advanced mechanical, chemical, and other methods to decontaminate structures, equipment, and materials
Liquid decontaminants for nuclear applications
International Nuclear Information System (INIS)
Henning, Klaus; Gojowczyk, Peter
2011-01-01
Decontaminants used in the nuclear field must meet a variety of requirements. On the one hand, the washing process must remove radioactive contamination and conventional dirt from the items washed. On the other hand, subsequent disposal of the washing water arisings must be feasible by the usual waste disposal pathway. One aspect of particular importance is unproblematic treatment of the radioactively contaminated waste water, as a rule low to medium active, whose final storage must be ensured. Decontaminants must not impair waste treatment processes, such as evaporation, filtration, and centrifuging, as well as further treatment of the concentrates and residues arising which are worked into matrix materials (cementation, bituminization), in drum drying or roller mill drying. For reasons of safety at work and environmental quality, also aspects of human toxicology and ecotoxicology must be taken into account. In this way, handling decontaminants will not jeopardize the health of personnel or cause potential long-term environmental damage. Liquid decontaminants, compared to powders, offer the advantage of automatic dosage. The liquid product is dosed accurately as a function of the washing program used. Liquid decontaminants can be handled safely in hot laundries without causing skin and eye contacts. (orig.)
International Nuclear Information System (INIS)
Wood, Joseph P.; Blair Martin, G.
2009-01-01
The numerous buildings that became contaminated with Bacillus anthracis (the bacterium causing the disease anthrax) in 2001, and more recent B. anthracis - related events, point to the need to have effective decontamination technologies for buildings contaminated with biological threat agents. The U.S. Government developed a portable chlorine dioxide (ClO 2 ) generation system to decontaminate buildings contaminated with B. anthracis spores, and this so-called mobile decontamination trailer (MDT) prototype was tested through a series of three field trials. The first test of the MDT was conducted at Fort McClellan in Anniston, AL. during October 2004. Four test attempts occurred over two weekends; however, a number of system problems resulted in termination of the activity prior to any ClO 2 introduction into the test building. After making several design enhancements and equipment changes, the MDT was subjected to a second test. During this test, extensive leak checks were made using argon and nitrogen in lieu of chlorine gas; each subsystem was checked for functionality, and the MDT was operated for 24 h. This second test demonstrated the MDT flow and control systems functioned satisfactorily, and thus it was decided to proceed to a third, more challenging field trial. In the last field test, ClO 2 was generated and routed directly to the scrubber in a 12-h continuous run. Measurement of ClO 2 levels at the generator outlet showed that the desired production rate was not achieved. Additionally, only one of the two scrubbers performed adequately with regard to maintaining ClO 2 emissions below the limit. Numerous lessons were learned in the field trials of this ClO 2 decontamination technology.
Decontamination of skin in emergency situation
International Nuclear Information System (INIS)
Harase, Chieko
1988-01-01
The report briefly discusses the organization of decontamination personnel and facilities to be used for decontamination in the event of an emergency, and outlines the author's experience in carrying out decontamination of the skin of tourists who came back to Japan after staying in Kiev at the time of the accident at Chernobyl (about 150 km away from Kiev). In Japan at present, no nuclear facilities seem to have sufficient personnel who are in charge of skin decontamination activities required in the event of an emergency, and emergency measures are generally limited to the development of emergency plans and implementation of drills. It is necessary to establish training courses for medical doctors and other medical personnel. Each plant has plans for skin decontamination procedures designed for professional workers in the plant. Plans should also be established for general people who might suffer skin decontamination in the event of an accident. What is the most important is to ease their anxiety about the contamination of their skin. The procedures, including washing and shampooing, used for the tourist returning from Kiev are described, and some problems encountered or expected to occur in similar cases are outlined and discussed. (Nogami, K.)
Decontamination strategies in contaminated settlement
International Nuclear Information System (INIS)
Hubert, P.; Jouve, A.; Tallec, V. Le
1996-01-01
Six years after the Chernobyl accident, decontamination actions had been completed in many places, the contamination could be considered as fixed, especially on urban surfaces and the social situation was felt to be stabilized. Under those conditions the efficiency of the 'classical' decontamination techniques was under question, it was worthwhile to look at new specific techniques. Besides it was necessary to discuss the interest of new decontamination actions in settlements. The European Union (EU) sponsored a project ECP 4 in order to look at the opportunities for further dose reduction actions in the contaminated territories of the three republics affected by the accident. The objective was to provide a local decision maker, faced with many alternatives for decontamination, with all the elements for determining what to do according to the various objectives he might pursue. The main results are presented here. (author)
Decommissioning and Decontamination
International Nuclear Information System (INIS)
Massaut, V.
2000-01-01
The objectives of SCK-CEN's decommissioning and decontamination programme are (1) to develop, test and optimise the technologies and procedures for decommissioning and decontamination of nuclear installations in order to minimise the waste arising and the distributed dose; (2) to optimise the environmental impact; (3) to reduce the cost of the end-of-life of the installation; (4) to make these new techniques available to the industry; (5) to share skills and competences. The programme and achievements in 1999 are summarised
International Nuclear Information System (INIS)
1999-04-01
A large increase in the number of casks required for transport and/or storage of spent fuel is forecast into the next century. The principal requirement will be for increased number of storage and dual purpose (transport/storage) casks for interim storage of spent fuel prior to reprocessing or permanent disposal in both on-site and off-site storage facilities. Through contact with radioactive materials spent fuel casks will be contaminated on both internal and external surfaces. In broad terms, cask contamination management can be defined by three components: minimisation, prevention and decontamination. This publication is a compilation of international experience with cask contamination problems and decontamination practices. The objective is to present current knowledge and experience as well as developments, trends and potential for new applications in this field. Furthermore, the report may assist in new design or modification of existing casks, cask handling systems and decontamination equipment
Method of decontaminating primary coolant circuits
International Nuclear Information System (INIS)
Ishibashi, Masaru; Sumi, Masao.
1981-01-01
Purpose: To eliminate hard contaminated layers as well as soft contaminated layers without injuring substrate materials, upon decontamination of radiation contaminated portions in equipments and pipeways constituting primary coolant circuits. Constitution: High pressure water from a high pressure pump is jetted out from the nozzle of a spray gun to the radiation contaminated portions in equipments, for example, to the surface of water chamber in a vapor evaporator. High pressure pure water or aqueous boric acid is jetted out from the periphery and boric oxide particles (of about 1 - 100 μ particle size) are jetted out from the center of the nozzle of the spray gun. The particles (blasting material) jetted out together with the high pressure water impinge on the contaminated surfaces to remove the contaminated layers. Upon impingement, the high pressure water acts as the shock absorber for the blasting material and, after the impingement, it flows down to the bottom of the water chamber, and the blasting material is dissolved in the high pressure water. (Horiuchi, T.)
Building surface decontamination for chemical counter-terrorism
Energy Technology Data Exchange (ETDEWEB)
Harrison, S.; Thouin, G.; Kuang, W. [SAIC Canada, Ottawa, ON (Canada); Volchek, K.; Fingas, M.; Li, K. [Environment Canada, Ottawa, ON (Canada). Emergencies Science and Technology Division, Environmental Technology Centre, Science and Technology Branch
2006-07-01
A test method to compare and evaluate surface decontamination methods for buildings affected by chemical attacks was developed. Decontamination techniques generally depend on the nature and quantity of the weapon agent, the type of construction material and the location. Cleanup methods can be either physical, chemical or biological. This paper addressed chemical decontamination methods which use reactants to change the molecular structure of the contaminant. Peroxycarboxylic and peroxyacetic acids (PAA) are being used increasingly for both disinfection and environmental protection. In this study, 4 materials were chosen to represent common building materials. Samples were spiked with 10 mg of pesticides such as malathion and diazinon. Decontamination agents included the commercial decontamination agent CASCAD prepared in liquid form, a chemical preparation of PAA, and reagent grade peroxypropionic acid (PPA). The newly developed surface decontamination procedure can evaluate and compare the effectiveness of different chemical decontamination agents. The procedures were used on porous ceiling tile and carpet as well as on non-porous floor tile and painted steel surfaces. Rinse water was collected and analyzed in order to determine if decontamination was a result of chemical destruction or mechanical removal. The extraction efficiencies were found to be acceptable for all materials, with the exception of the highly porous ceiling tile. The extraction of diazinon from all surfaces was less efficient than the extraction of malathion. Results suggest that the performance of decontamination agents can be improved by repeated application of the decontamination agent, along with greater volumes and a combination of chemical and mechanical actions. It was also suggested that breakdown methods and wastewater treatment procedures should be developed because hazardous byproducts were detected in many samples. 18 refs., 1 tab., 17 figs.
A study on the decontamination of the gravels contaminated by uranium
Energy Technology Data Exchange (ETDEWEB)
Park, Ukryang; Kim, Gyenam; Kim, Seungsoo; Moon, Jaikwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2014-05-15
The amount of gravels contaminated by uranium is usually about 10% of the contaminated soil. Since such contaminated gravels show different kinds and volumes, it would cost a considerable amount of money if they are to be disposed of without going through any special process. Also, there has not been any particular way or technology for processing the gravels contaminated by uranium. Therefore, various fundamental experiments and researches have been carried out for the decontamination of the gravels contaminated by uranium. Through such experiments and researches, it has been possible to obtain some significant results. The acid cleaning process, which is based on the application of the soil cleaning method, can be regarded as one of the major ways used for decontamination. When the gravels contaminated by uranium are cleaned as they are, most of them tend to show an extremely-low level of decontamination. Therefore, it could be said that the inside of each gravel is also contaminated by uranium. As a result, the gravels contaminated by uranium need to be crushed before being cleaned, which would result in a higher level of efficiency for decontamination compared to the previous way. Therefore, it is more effective to crush the subject gravels before cleaning them in terms of decontamination. However, such test results can only be applied to the gravels contaminated by an average level of uranium concentration. Regarding the gravels showing a higher level of uranium concentration than the average, it is still necessary to carry out more researches. Therefore, this study focused on the level of efficiency for decontamination after the contaminated gravels were crushed before being cleaned, in order to find a way to effectively dispose of the gravels contaminated by high-concentration uranium and secure a high level of efficiency for decontamination. In order to decontaminate the gravels which were contained in the soil contaminated by uranium and showed a higher
Study of the characterization and formulation of the decontamination gels
Energy Technology Data Exchange (ETDEWEB)
Park, Youn Bong; Bang, In Bae; Bae, Bong Moon; Oh, Gyu Hwan [Chungnam National University, Daejeon (Korea, Republic of)
2011-04-15
To develop a chemical gel decontamination technology for a removal of non-fixed contaminants during the maintenance and decommissioning works of high radiation hot cells which have been used for a recycling or treatment of spent fuels we have prepare gels with CAB-O-SIL M-5 or Aerosil 380 as viscosifier and some non-ionic surfactants such as diethylene glycol hexyl ether, triethylene glycol dodecyl ether, polyethylene glycol 600, and triethylene glycol butyl ether. Surfactants are playing important roles in manipulating the properties of decontamination the gels. We have found the CAB-O-SIL with triethylene glycol butyl ether and Aerosil with triethylene glycol dodecyl ether systems promising for the decontamination work
Study of the characterization and formulation of the decontamination gels
International Nuclear Information System (INIS)
Park, Youn Bong; Bang, In Bae; Bae, Bong Moon; Oh, Gyu Hwan
2011-04-01
To develop a chemical gel decontamination technology for a removal of non-fixed contaminants during the maintenance and decommissioning works of high radiation hot cells which have been used for a recycling or treatment of spent fuels we have prepare gels with CAB-O-SIL M-5 or Aerosil 380 as viscosifier and some non-ionic surfactants such as diethylene glycol hexyl ether, triethylene glycol dodecyl ether, polyethylene glycol 600, and triethylene glycol butyl ether. Surfactants are playing important roles in manipulating the properties of decontamination the gels. We have found the CAB-O-SIL with triethylene glycol butyl ether and Aerosil with triethylene glycol dodecyl ether systems promising for the decontamination work
Radiation level assessment of the Dresden-1 decontamination pilot loop
International Nuclear Information System (INIS)
1978-05-01
The radionuclide concentrations of the Dresden-1 decontamination pilot loop were determined by gamma spectroscopy. The General Electric Ge(Li)pipe gamma scanning system was utilized to take measurements at eight locations both before and after the pilot demonstration of decontamination process. Dose rate measrurements were taken with a portable gamma monitor at 30 additional locations. The percentage of Co-60 removed was calculated and the results were interpreted
Developing technique for waste water cleaning of a division for equipment decontamination
International Nuclear Information System (INIS)
Gromoglasov, A.A.; Solyakov, V.K.; Novikov, V.N.; Pil'shchikov, A.P.; Chekalov, A.G.; Sinyukov, M.A.; Pshenichnykh, V.N.
1989-01-01
Results are described of developing technique for radionuclide cleaning solutions after metal product decontamination. The method is based on the adagulation with usage of quicklime. The conclusion is method permits to consider it as the main technique for waste water decontamination. 3 refs.; 2 figs.; 3 tabs
A sensitive, handheld vapor sensor based on microcantilevers
Pinnaduwage, L. A.; Hedden, D. L.; Gehl, A.; Boiadjiev, V. I.; Hawk, J. E.; Farahi, R. H.; Thundat, T.; Houser, E. J.; Stepnowski, S.; McGill, R. A.; Deel, L.; Lareau, R. T.
2004-11-01
We report the development of a handheld sensor based on piezoresistive microcantilevers that does not depend on optical detection, yet has high detection sensitivity. The sensor is able to detect vapors from the plastic explosives pentaerythritol tetranitrate and hexahydro-1,3,5-triazine at levels below 10 parts per trillion within few seconds of exposure under ambient conditions. A differential measurement technique has yielded a rugged sensor that is unaffected by vibration and is able to function as a "sniffer." The microelectromechanical system sensor design allows for the incorporation of hundreds of microcantilevers with suitable coatings in order to achieve sufficient selectivity in the future, and thus could provide an inexpensive, unique platform for the detection of chemical, biological, and explosive materials.
[Decontamination of dental unit waterlines using disinfectants and filters].
Monarca, S; Garusi, G; Gigola, P; Spampinato, L; Zani, C; Sapelli, P L
2002-10-01
Bacterial contamination of the dental unit water system can become a health problem for patients, particularly if they are immunodepressed. The present study has had the purpose of evaluating the effectiveness of methods of chemical decontamination using different disinfectants (peracetic acid, hydrogen peroxide, silver salts, chloramine T, glutaraldehyde T4) and methods of physical decontamination using synthetic membranes for the filtration of water. A preliminary removal procedure of the biofilm present in the waterline has been followed in a dental unit prepared on purpose for the research; subsequently different 2-week long maintenance procedures were applied using disinfectants injected by a pump and finally the bacterial contamination of the water flowing from the waterline was evaluated. The physical decontamination was performed using 0.22 mm membrane filters, which have been installed also in another dental unit, and the filtered water was analyzed to detect bacterial contamination. The preliminary procedure of biofilm removal succeeded obtaining germ-free water. Among the disinfectants used for the maintenance of the water quality only glutaraldehyde T4 was able to reduce the bacterial contamination under the limit suggested by the ADA. The membrane filter system was not able to purify the water, but when a disinfectant (peracetic acid) was used in the last part of the waterline good results were obtained. At present no decontamination system of dental waterline is available, and glutaraldehyde T4 seems to be the best disinfectant only if integrated with periodic biofilm removal for the maintenance of the water quality.
Use of process indices for simplification of the description of vapor deposition systems
International Nuclear Information System (INIS)
Kajikawa, Yuya; Noda, Suguru; Komiyama, Hiroshi
2004-01-01
Vapor deposition is a complex process, including gas-phase, surface, and solid-phase phenomena. Because of the complexity of chemical and physical processes occurring in vapor deposition processes, it is difficult to form a comprehensive, fundamental understanding of vapor deposition and to control such systems for obtaining desirable structures and performance. To overcome this difficulty, we present a method for simplifying the complex description of such systems. One simplification method is to separate complex systems into multiple elements, and determine which of these are important elements. We call this method abridgement. The abridgement method retains only the dominant processes in a description of the system, and discards the others. Abridgement can be achieved by using process indices to evaluate the relative importance of the elementary processes. We describe the formulation and use of these process indices through examples of the growth of continuous films, initial deposition processes, and the formation of the preferred orientation of polycrystalline films. In this paper, we propose a method for representing complex vapor deposition processes as a set of simpler processes
Phase relationship, vaporization, and thermodynamic properties of the lanthanum--boron system
International Nuclear Information System (INIS)
Storms, E.; Mueller, B.
1978-01-01
The La-B system was studied between LaB/sub 4.24/ and LaB/sub 29.2/, and between 1400 and 2100 K to determine the phase relationship, the chemical activity of the components, the vaporization rate, and the vapor composition. A blue colored phase near LaB 9 was found to exist between purple colored LaB 6 and elemental boron. Diffusion is so much slower than vaporization that large composition differences can exist between the surface and the interior which, nevertheless, produce a steady state loss rate from freely vaporizing material. The flux at 1700 K is 6 x 10 -10 g/cm 2 s for LaB 4 +LaB 6 and 7 x 10 -11 g/cm 2 s for LaB 6 + LaB 9 . There is an activation energy which lowers the vaporization rate of boron from LaB 6 . Freely vaporizing material will have a steady state surface composition between LaB/sub 6.04/ and LaB/sub 6.07/, depending on temperature, purity, and interior composition. The free energy of formation of LaB 6 is (0.07lT - 351)kJ/mol between 1700 and 2100 K
Post-accident TMI-2 (Three Mile Island-Unit 2) decontamination and defueling
International Nuclear Information System (INIS)
Hofstetter, K.J.; Baston, V.F.
1986-01-01
Following the accident at Three Mile Island-Unit 2 (TMI-2), a substantial quantity of fission products was distributed throughout various plant systems and areas. The control of further migration of these radionuclides was accomplished by various physical and chemical means. The decontamination and defueling activities have proceeded within specific regulatory, administrative, and hardware restrictions. A summary of the post-accident status of the plant systems, the decontamination methods used, and the end-point criteria will be discussed. The hardware installed or utilized to perform the cleanup operations will be described. The methods and progress of defueling will also be presented. The development of detailed water chemistry requirements and their effects on systems and decontamination efforts are discussed. The planning, scheduling, and performance of specific recovery tasks are presented along with a general overview of water and chemical management at TMI-2
International Nuclear Information System (INIS)
Huckaby, J.L.; Edwards, J.A.; Evans, J.C.
1996-08-01
This report discusses comparison tests for two methods of collecting vapor samples from the Hanford Site high-level radioactive waste tank headspaces. The two sampling methods compared are the truck-mounted vapor sampling system (VSS) and the cart-mounted in-situ vapor sampling (ISVS). Three tanks were sampled by both the VSS and ISVS methods from the same access risers within the same 8-hour period. These tanks have diverse headspace compositions and they represent the highest known level of several key vapor analytes
Measurement of Ce(IV) Concentration in Foam Decontaminant containing Fluorosurfactant
Energy Technology Data Exchange (ETDEWEB)
Jung, Chong Hun; Yang, H. B.; Yoon, I. H.; Choi, W. K.; Moon, J. K. [KAERI, Daejeon (Korea, Republic of); Lee, J. S. [Gachon University, Seongnam (Korea, Republic of)
2016-05-15
To improve the stability of the foam, surfactants and inorganic materials such as nanoparticles can be added. A nanoparticle-based foam decontaminant is composed of a surfactant and nanoparticles for the generation and maintenance of foam, and a chemical decontamination agent made of Ce(IV) dissolved in nitric acid. Ce(IV) will be reduced to Ce(III) through the decontamination process. Oxidizing the cerium (III) can be reused as a decontamination agent, Ce(IV). Oxidation treatment technology by ozone uses its strong oxidizing power. It can be regarded as an environmentally friendly process, because ozone cannot be stored and transported like other industrial gases (because it quickly decays into diatomic oxygen) and must therefore be produced on site, and used ozone can be decomposed immediately. A concentration analysis of Ce(IV) in foam decontaminant containing a surfactant is necessary prior to the derivation of optimal conditions for the regeneration of Ce(III) through ozonation treatment. A UV spectrometric method using the absorbance or potentiometric method with a potential difference in Ce(III)/Ce(IV), or a potentiometric titration method using Fe (II), can be used for a Ce(IV) concentration analysis. A UV spectrometric method has a problem receiving the influence of the surfactant, and a potentiometric method is difficult to use because of the problem of an insignificant change in the potential difference value of the Ce(III)/Ce(IV). Thus, the present study was undertaken to determine whether the potentiometric titration method can be used for an analysis of the Ce(IV) concentration in the nanoparticle-based foam decontaminant containing surfactant. It will be effectively used for the Ce(IV) concentration measurement, in relation to the subsequent research on the derivation of optimal conditions for the regeneration of Ce(III) through ozonation treatment.
Development of remote electrochemical decontamination for hot cell applications
International Nuclear Information System (INIS)
Turner, A.D.; Junkison, A.R.; Pottinger, J.S.; Lain, M.J.; Neville, M.D.; Dawson, R.K.; Fletcher, P.A.; Fenn-Tye, I.A.
1993-01-01
Electrochemical dissolution into nitric acid has been developed as a decontamination process for metallic items, both for immersion and in-situ use. Not only is the spent electrolyte compatible with existing waste treatment routes, potentially yielding an immobilized product volume of 0.6 dm 3 /m 2 area treated, but it also suppresses any hydrogen production. Both processes have been developed from laboratory to microprocessor-controlled pilot-scale units, which have been demonstrated successfully for the treatment of genuine waste, reducing activity levels to background. For stainless steel substrates, the immersion tank process uses low current densities (10-50 A/m 2 ) in 1-5M HN0 3 for the treatment of extended areas. Decontamination factors > 10 4 can be achieved in two hours. The in-situ technique uses electropolishing in 6M HN0 3 at 1-2 A/cm 2 in an engineered head. Decontamination factors > 10 3 can be achieved in only 20 seconds. This device has also shown potential for incorporation into an integrated monitoring/decontaminating system under robotic control. Both techniques may be used remotely as a way of reducing man-dose and improving productivity during decontamination. Additional cost savings can be made over currently used techniques through the decategorization of the bulk of the waste volume, and the volume reduction of waste for interim storage and geological disposal
Pickering emulsions for skin decontamination.
Salerno, Alicia; Bolzinger, Marie-Alexandrine; Rolland, Pauline; Chevalier, Yves; Josse, Denis; Briançon, Stéphanie
2016-08-01
This study aimed at developing innovative systems for skin decontamination. Pickering emulsions, i.e. solid-stabilized emulsions, containing silica (S-PE) or Fuller's earth (FE-PE) were formulated. Their efficiency for skin decontamination was evaluated, in vitro, 45min after an exposure to VX, one of the most highly toxic chemical warfare agents. Pickering emulsions were compared to FE (FE-W) and silica (S-W) aqueous suspensions. PE containing an oil with a similar hydrophobicity to VX should promote its extraction. All the formulations reduced significantly the amount of VX quantified on and into the skin compared to the control. Wiping the skin surface with a pad already allowed removing more than half of VX. FE-W was the less efficient (85% of VX removed). The other formulations (FE-PE, S-PE and S-W) resulted in more than 90% of the quantity of VX removed. The charge of particles was the most influential factor. The low pH of formulations containing silica favored electrostatic interactions of VX with particles explaining the better elimination from the skin surface. Formulations containing FE had basic pH, and weak interactions with VX did not improve the skin decontamination. However, these low interactions between VX and FE promote the transfer of VX into the oil droplets in the FE-PE. Copyright © 2016 Elsevier B.V. All rights reserved.
An experimental study on decontamination by surface condition
International Nuclear Information System (INIS)
Lee, Young Hae
1974-01-01
Surface decontamination is one of the very important problem to be completely solved in the isotope laboratory where there is always the possibility of radioactive contamination, i.e., on the floors, walls, working tables and benches etc., Isotope laboratories require surface covering of material which can be easily and effectively decontaminated. These experiment were done to find an effective decontamination procedure for kind of surfaces which usually are found in radioisotope laboratories and the best type of surface material, that is, one which is easily decontaminated from the point of view of radiation health and safely. This study is presented to guide radioisotope laboratories in Korea which may need to renovate existing unsafe facilities. In some contaminated facilities entirely new installations may be required. Twelve types of surface material are used for study in this experiment. These include 10 cm square of stainless steel, aluminum, ceramic and mosaic tiles, glass, acrylic, formica board, asphalt tile and coated wood with 4 kinds of paints. Stepwise decontamination was performed with various decontamination procedures following a spill of I 1 31 on the center of the surface material being tested. Twelve different decontamination procedures were tested. These included wet wiping with water and detergent, or dry wiping, or removing with gummed paper. Additional chemical procedures used 10% solution of hydrochloric acid, or surface acid, or ammonium citrate, or potassium iodide, or acetone or carbon tetrachloride. The final testing method was abrasion of the test surfaces. Brief analysis of experimental results on the decontaminability on the tested surface showed: 1. Metallic surfaces such as stainless steel or aluminum, or glass, or a piece of ceramic tile or acrylic are recommended as the surface materials for isotope laboratories because these are easily decontaminated by wet wiping only. 2. Formica board, asphalt tile and wood are not easily
Decontamination and decommissioning techniques for research reactors
International Nuclear Information System (INIS)
Oh, Won Zin; Won, H. J.; Jung, C. H.; Choi, W. K.; Kim, G. N.; Lee, K. W.
2002-05-01
Evaluation of soil decontamination process and the liquid decontamination waste treatment technology are investigation of organic acid as a decontamination agent, investigation of the liquid waste purification process and identification of recycling the decontamination agents. Participation on IAEA CRP meeting are preparation of IAEA technical report on 'studies on decommissioning of TRIGA reactors and site restoration technologies' and exchange the research result, technology, experience and safety regulation of the research reactor D and D of USA, Great Britain, Canada, Belgium, Italy, India and so forth
Theory of soil decontamination in mixing liquid
International Nuclear Information System (INIS)
Polyakov, A.S.; Emets, E.P.; Poluehktov, P.P.; Rybakov, K.A.
1997-01-01
The theory of soil decontamination from radioactive pollution in mixing liquid flow is described. It is shown that there exists the threshold intensity of liquid mixing up to which there is no decontamination. Beyond the threshold and by increasing the mixing intensity the decontamination of large soil fractions is allowable whereby the higher is the mixing intensity and lower is the soil contamination, the laser is the characteristic decontamination time. The above theory is related to cases of uniform pollution of the particles surface
Proposed draft standard ANS 11.18: recommendations to facilitate decontamination and decommissioning
International Nuclear Information System (INIS)
Jenkins, C.E.; LaGuardia, T.S.; Jones, J.W.
1981-01-01
The purpose of ANS Standard 11.18 is to recommend design guides to facilitate decontamination and eventual decommissioning of a remotely operated radioactive facility. This design guide contains generic recommendations to assist in the planning, selection and arrangement of equipment and materials, and the protection of surfaces to enhance system decontamination and disassembly
Organic decontamination by ion exchange
International Nuclear Information System (INIS)
Wilson, T.R.
1994-01-01
This study has successfully identified ion exchanger media suitable for decontaminating the 5500-gallon organic layer in Tank 241-C-103. Decontamination of radionuclides is necessary to meet shipping, incinerator site storage, and incineration feed requirements. The exchanger media were identified through a literature search and experiments at the Russian Institute for Physical Chemistry. The principal radionuclides addressed are Cs-137 and Sr-90. Recommendations for an experimental program plan conclude the discussion. The experimental program would provide the data necessary for plant design specifications for a column and for ion exchange media to be used in decontaminating the organic layer
Estimated effects of interfacial vaporization on fission product scrubbing
International Nuclear Information System (INIS)
Moody, F.J.; Nagy, S.G.
1983-01-01
When bubbles containing non-condensible gas rise through a water pool, interfacial evaporation causes a flow of vapor into the bubbles. The inflow reduces the outward particle motion toward the bubble wall, diminishing the effectiveness of fission product particle removal. This analysis provides an estimate of evaporation on pool scrubbing effectiveness. It is shown that hot gas, which boils water at the bubble wall, reduces the effective scrubbing height by less than five centimeters. Although the evaporative humidification in a rising bubble containing non-condensible gas has a diminishing effect on scrubbing mechanisms, substantial decontamination is still expected even for the limiting case of a saturated pool
Mesoporous titanium-manganese dioxide for sulphur mustard and soman decontamination
International Nuclear Information System (INIS)
Stengl, Vaclav; Bludska, Jana; Oplustil, Frantisek; Nemec, Tomas
2011-01-01
Highlights: → New nano-dispersive materials for warfare agents decontamination. → 95% decontamination activities for sulphur mustard. → New materials base on titanium and manganese oxides. -- Abstract: Titanium(IV)-manganese(IV) nano-dispersed oxides were prepared by a homogeneous hydrolysis of potassium permanganate and titanium(IV) oxo-sulphate with 2-chloroacetamide. Synthesised samples were characterised using Brunauer-Emmett-Teller (BET) surface area and Barrett-Joiner-Halenda porosity (BJH), X-ray diffraction (XRD), infrared spectroscopy (IR), and scanning electron microscopy (SEM). These oxides were taken for an experimental evaluation of their reactivity with sulphur mustard (HD or bis(2-chloroethyl)sulphide) and soman (GD or (3,3'-dimethylbutan-2-yl)-methylphosphonofluoridate). Mn 4+ content affects the decontamination activity; with increasing Mn 4+ content the activity increases for sulphur mustard and decreases for soman. The best decontamination activities for sulphur mustard and soman were observed for samples TiMn 3 7 with 18.6 wt.% Mn and TiMn 5 with 2.1 wt.% Mn, respectively.
Development of chemical decontamination process with sulfuric acid-cerium (IV) for decommissioning
International Nuclear Information System (INIS)
Suwa, Takeshi; Kuribayashi, Nobuhide; Tachikawa, Enzo
1988-01-01
The electrolytic regeneration of Ce 4+ from Ce 3+ , which is required to achieve a high decontamination factor (DF) in this process, has been investigated. A calculating model was derived for the regenerating current required during the decontamination as a function of dissolution rate of crud, corrosion rate (R c ), current efficiency (η e ) and characteristics of decontamination loop. From the above calculation, it was found that the current was mainly governed by R c and η e . A condition to obtain a high DF at low R c and high η e has been found experimentally by use of a mixture of Ce 3+ at the ratio of Ce 4+ /Ce 3+ = 0.1 ∼ 0.2. The desired values to be η e ≥ 80 % at above 50 A/m 2 was obtained under the flow rate above 300 cm/min and Ce 3+ concentration above 10 x 10 -3 M at 60 deg C using the dual-cylindrical type cell. The current efficiency was also investigated with cells of various geometries. The present decontamination process has been proposed as a system decontamination process, which is essentially a single-step decontamination process for Cr-rich oxides. (author)
New decontamination techniques: chemical gels, electropolishing and abrasives
International Nuclear Information System (INIS)
Brunel, G.; Gauchon, J.P.; Kervegant, Y.; Josso, F.
1991-01-01
The decommissioning of nuclear installations requires decontamination techniques that are efficient, simple to apply and producing a small amount of wastes, which are easy to process. With a view to this, three decontamination methods, which appear to be particularly suited to decommissioning, have been studied. These three methods are: - spraying of gels carrying chemical decontaminating agents, - electropolishing with a swab device, - abrasives blasting. After parametric tests on non-radioactive and active samples, the industrial application of these methods in the dismantling of installations was studied. These industrial applications concern: - decontamination of pieces coming from the German BWR ISAR by immersion and gel spraying, - decontamination, mainly by gel spraying, and dismantling of the BRENNILIS bituminisation plant, - decontamination of part of the cooling circuit of the graphite gas reactor G2 by gel spraying, - decontamination of a component of the FBR SuperPhenix, using dry abrasives blasting. During the first three applications, generated secondary wastes volume and form were determined. 33 tabs., 16 figs., 12 refs
MERCURY CONTAMINATED MATERIAL DECONTAMINATION METHODS: INVESTIGATION AND ASSESSMENT; TOPICAL
International Nuclear Information System (INIS)
M.A. Ebadian, Ph.D.
2001-01-01
Over the years mercury has been recognized as having serious impacts on human health and the environment. This recognition has led to numerous studies that deal with the properties of various mercury forms, the development of methods to quantify and speciate the forms, fate and transport, toxicology studies, and the development of site remediation and decontamination technologies. This report reviews several critical areas that will be used in developing technologies for cleaning mercury from mercury-contaminated surfaces of metals and porous materials found in many DOE facilities. The technologies used for decontamination of water and mixed wastes (solid) are specifically discussed. Many technologies that have recently appeared in the literature are included in the report. Current surface decontamination processes have been reviewed, and the limitations of these technologies for mercury decontamination are discussed. Based on the currently available technologies and the processes published recently in the literature, several processes, including strippable coatings, chemical cleaning with iodine/iodide lixiviant, chemisorbing surface wipes with forager sponge and grafted cotton, and surface/pore fixation through amalgamation or stabilization, have been identified as potential techniques for decontamination of mercury-contaminated metal and porous surfaces. Their potential merits and applicability are discussed. Finally, two processes, strippable coatings and chemical cleaning with iodine/iodide lixiviant, were experimentally investigated in Phase II of this project
Geographic assistance of decontamination strategy elaboration
International Nuclear Information System (INIS)
Davydchuk, V.; Arapis, G.
1996-01-01
Those who elaborates the strategy of decontamination of vast territories is to take into consideration the heterogeneity of such elements of landscape as relief, lithology, humidity and types of soils and, vegetation, both on local and regional level. Geographic assistance includes evaluation of efficacy of decontamination technologies in different natural conditions, identification of areas of their effective application and definition of ecological damage, estimation of balances of the radionuclides in the landscapes to create background of the decontamination strategy
Strippable gel for decontamination of contaminated metallic surfaces
International Nuclear Information System (INIS)
Banerjee, D.; Sandhya, U.; Khot, S.A.; Srinivas, C.; Wattal, P.K.
2013-01-01
Periodic decontamination of radioactive laboratories including fume hoods, glove boxes and all surfaces used for handling, processing and transporting radioactive materials is mandatory in all nuclear installations as this reduces spread of contamination and decreases total man rem exposure. Conventionally, chemical decontaminating agents or surfactant solutions are used for this purpose. However, this approach leads to generation of large volume of secondary radioactive waste. The use of strippable gel is an attractive alternative with low secondary waste generation particularly where removal of loose or weakly fixed contamination is necessary and also when the decontaminated material are to be reused, for e.g. decontamination of fume hoods, glove boxes, transport casks, spent fuel storage racks, control rod drive transport containers etc. Literature on gel formulations is scarce and mostly in the patent form. The sustained effort on gel formulation development has resulted in a basic gel formulation. The gel is a highly viscous water-based organic polymer, particularly suitable for application on vertical surfaces including difficult to reach metallic surfaces of complex geometry and not just limited to horizontal surfaces. The gel can be easily applied on contaminated surfaces by brushing or spraying. Curing of the gel is complete within 16-24 hours under ambient conditions and can then be removed by peeling as a dry sheet. While curing, the contaminants are trapped in gel either physically or chemically depending upon the nature of the contaminant. Salient features of cured gel include that it is water soluble and can be disposed off after immobilization in cement. Decontamination performance of the gel was initially evaluated by applying it on SS planchettes contaminated with known amount of radionuclides such as Cs(I), Co(II) and Ce(III). The measured decontamination factor was found to be in the range of 50-500, lowest for Ce(III) and highest for Co
Tank Vapor Characterization Project: Annual status report for FY 1996
International Nuclear Information System (INIS)
Silvers, K.L.; Fruchter, J.S.; Huckaby, J.L.; Almeida, T.L.; Evans, J.C. Jr.; Pool, K.H.; Simonen, C.A.; Thornton, B.M.
1997-01-01
In Fiscal Year 1996, staff at the Vapor Analytical Laboratory at Pacific Northwest National Laboratory performed work in support of characterizing the vapor composition of the headspaces of radioactive waste tanks at the Hanford Site. Work performed included support for technical issues and sampling methodologies, upgrades for analytical equipment, analytical method development, preparation of unexposed samples, analyses of tank headspaces samples, preparation of data reports, and operation of the tank vapor database. Progress made in FY 1996 included completion and issuance of 50 analytical data reports. A sampling system comparison study was initiated and completed during the fiscal year. The comparison study involved the vapor sampling system (VSS), a truck-based system, and the in situ vapor sampling system (ISVS), a cart-based system. Samples collected during the study were characterized for inorganic, permanent gases, total non-methane organic compounds and organic speciation by SUMMA trademark and TST methods. The study showed comparable sampling results between the systems resulting in the program switching from the VSS to the less expensive ISVS methodology in late May 1996. A temporal study was initiated in January 1996 in order to understand the influences seasonal temperatures changes have on the vapors in the headspace of Hanford waste tanks. A holding time study was initiated in the fourth quarter of FY 1996. Samples were collected from tank S-102 and rushed to the laboratory for time zero analysis. Additional samples will be analyzed at 1, 2, 4, 8, 16, and 32 weeks
Facility decontamination technology workshop
International Nuclear Information System (INIS)
1980-10-01
Purpose of the meeting was to provide a record of experience at nuclear facilities, other than TMI-2, of events and incidents which have required decontamination and dose reduction activities, and to furnish GPU and others involved in the TMI-2 cleanup with the results of that decontamination and dose reduction technology. Separate abstracts were prepared for 24 of the 25 papers; the remaining paper had been previously abstracted
Special zone territory decontamination
International Nuclear Information System (INIS)
Samojlenko, Yu.N.; Golubev, V.V.
1989-01-01
Special zone is the Chernobyl' NPP operating site (OS). OS decontamination is described including reactor ruins from the accident moment. The process was begun from reactor bombardment with absorbing and filtering materials (sand, clay, lead, boron compounds). Then were produced soil shovelling, territory filling by dry concrete and laying concrete layer with thickness up to 300 mm. NPP room and equipment decontamination is described. 3 figs.; 3 tabs
Facility decontamination technology workshop
Energy Technology Data Exchange (ETDEWEB)
None
1980-10-01
Purpose of the meeting was to provide a record of experience at nuclear facilities, other than TMI-2, of events and incidents which have required decontamination and dose reduction activities, and to furnish GPU and others involved in the TMI-2 cleanup with the results of that decontamination and dose reduction technology. Separate abstracts were prepared for 24 of the 25 papers; the remaining paper had been previously abstracted. (DLC)
Evaluation of laryngoscopes decontamination practices in different hospitals
International Nuclear Information System (INIS)
Ahmad, M.; Hussain, W.; Saleem, A.; Saqib, M
2014-01-01
To find disinfection and sterilization practices of laryngoscope in different hospitals. Study Design: Descriptive study. Materials and Methods: Laryngoscope decontamination practices in different hospitals were evaluated in this study which was based on a telephonic structured questionnaire. Preset questions were asked on phone from operation room technicians of 50 different hospitals. For clarification and confirmation of procedure anesthesiologist of the hospital was contracted. Laryngoscope decontamination practices were asked as per questionnaire and data collected was recorded and analyzed. Results were documented and compared with studies regarding laryngoscope decontamination practices of different countries. Results: Most exercised methods were manual decontamination with simple gauze (50%), alcohol gauze (11%) or tap water (27%). The use of disposable blades and sheathing of blades was not practiced by any of the hospitals. Similarly chemical disinfectants were used rarely (2%). Rinsing laryngoscopes with water (always 27%, sometimes 23%) was very common while, autoclaving or sheathing of blades was not done in any of the hospital. Conclusion: The rate of different postoperative infection is on the increase in our hospitals and one likely contributing source is contaminated laryngoscopes. Lack of awareness and poor practices among health care professionals, over work and economic constraints are the major contributing factors which need to be controlled by adhering to international standards. (author)
Passive vapor extraction feasibility study
International Nuclear Information System (INIS)
Rohay, V.J.
1994-01-01
Demonstration of a passive vapor extraction remediation system is planned for sites in the 200 West Area used in the past for the disposal of waste liquids containing carbon tetrachloride. The passive vapor extraction units will consist of a 4-in.-diameter pipe, a check valve, a canister filled with granular activated carbon, and a wind turbine. The check valve will prevent inflow of air that otherwise would dilute the soil gas and make its subsequent extraction less efficient. The granular activated carbon is used to adsorb the carbon tetrachloride from the air. The wind turbine enhances extraction rates on windy days. Passive vapor extraction units will be designed and operated to meet all applicable or relevant and appropriate requirements. Based on a cost analysis, passive vapor extraction was found to be a cost-effective method for remediation of soils containing lower concentrations of volatile contaminants. Passive vapor extraction used on wells that average 10-stdft 3 /min air flow rates was found to be more cost effective than active vapor extraction for concentrations below 500 parts per million by volume (ppm) of carbon tetrachloride. For wells that average 5-stdft 3 /min air flow rates, passive vapor extraction is more cost effective below 100 ppm
International Nuclear Information System (INIS)
Gogoi, T.K.; Talukdar, K.
2014-01-01
Highlights: • Exergy analysis of a combined power–absorption cooling system is provided. • Exergetic efficiency of the power cycle and absorption cooling system are calculated. • Irreversibility in each component and total system irreversibility are calculated. • Effect of operating parameters on exergetic performance and irreversibility is analyzed. • Optimum operating parameters are identified based on energy and exergy based results. - Abstract: In this paper, exergy analysis of a combined reheat regenerative steam turbine (ST) based power cycle and water–LiBr vapor absorption refrigeration system (VARS) is presented. Exergetic efficiency of the power cycle and VARS, energy utilization factor (EUF) of the combined system (CS) and irreversibility in each system component are calculated. The effect of fuel flow rate, boiler pressure, cooling capacity and VARS components’ temperature on performance, component and total system irreversibility is analyzed. The second law based results indicate optimum performance at 150 bar boiler pressure and VARS generator, condenser, evaporator and absorber temperature of 80 °C, 37.5 °C, 15 °C and 35 °C respectively. The present exergy based results conform well to the first law based results obtained in a previous analysis done on the same combined system. Irreversibility distribution among various power cycle components shows the highest irreversibility in the cooling tower. Irreversibility of the exhaust flue gas leaving the boiler and the boiler are the next major contributors. Among the VARS components, exergy destruction in the generator is the highest followed by irreversibility contribution of the absorber, condenser and the evaporator
Correlation Study of Magnetite Dissolution in Hybrid Decontamination Process
Energy Technology Data Exchange (ETDEWEB)
Kim, Seon-Byeong; Won, Hui-Jun; Park, Jung-Sun; Park, Sang-Yoon; Moon, Jei-Kwon; Choi, Wang-Kyu [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2016-10-15
In the operating plants, the localized corrosion on SG tubes which are transporters of thermal energy to the secondary side lowers the reduction heat transfer efficiency as well as degrades the lifetime of SG. Magnetite, Fe3O4, is a commonly found corrosion product on the inner surface of reactor coolant system. Simply magnetite can be reduced to hematite, Fe{sub 2}O{sub 3}, and further to iron when oxygen is limited or ample reducing agents are supplied. Along this line, number of decontamination processes has been developed since 1970s and most of them contain organic acid and additive chelating agents. However, many reports have pointed out the negative environmental effect of those chemicals, and currently there are new approaches to overcome the limited decontamination efficiency and large volume of secondary waste from other alternate processes without using such those organic chemicals. In present study, we investigated the magnetite dissolution in HyBRID solution as newly developing decontamination process. As a preliminary study for empirical modeling of decontamination by HyBRID solution, simply correlation study between variable and magnetite dissolution was introduced with studied mechanism and experimental results.
Dynamic simulation of a forced circulation evaporating system
International Nuclear Information System (INIS)
Lee, J.S.; Lee, K.J.
1993-01-01
A dynamic simulation program has been developed to simulate the forced circulation evaporating system of the Kori PWR Power Plant in Korea which is used to treat liquid waste containing boric acid. Energy and mass balances for the vapor and liquid phases are used to describe the interaction among system components such as the vapor body, heater jacket and condenser. In order to simulate entrainment carryover in the sieve tray column and wire mesh pad, Kister's and Carpenter-Othmer's correlations are adopted, respectively. A new correlation formula is also suggested to simulate the geometric effect of the vapor body. A fuzzy heuristic controller and conventional controllers such as P (proportional), PI (proportional-integral) and PID (proportional-integral-derivative) controls are incorporated to observe their responses to a given disturbance. The simulations show good agreement with the real operation data. It is also identified that the vapor velocity or flow rate in the sieve tray column determines the system decontamination factor (DF), and that the longer the vapor body is, the less entrainment carryover occurs out of the vapor body. In addition, the wire mesh pad is identified as maintaining very high deentrainment efficiency even though the vapor velocity may show large fluctuations. With respect to system control, the fuzzy heuristic controller approaches a new steady state faster than conventional controllers. Also the fuzzy controller maintains higher DF during transients and is stronger against time delay in the control components. (Author)
International Nuclear Information System (INIS)
Bregani, F.; Pascali, R.; Rizzi, R.
1984-01-01
The aim of the research activities described was to develop vigorous decontamination techniques for decommissioning purposes, taking into account the cost of treatment of the radwaste, to achieve possibly unrestricted release of the treated components, and to obtain know-how for in situ hard decontamination. The decontamination procedures for strong decontamination have been optimized in static and dynamic tests (DECO-loop). The best values have been found for: (i) hydrochloric acid: 4 to 5% vol. at low temperature, 0.7 to 1% vol. at high temperature (80 0 C); (ii) hydrofluoric plus nitric acid: 1.5% vol. HF + 5% vol. HNO 3 at low temperature; 0.3 to 0.5% vol. HF + 2.5 to 5% vol. HNO 3 at high temperature. High flow rates are not necessary, but a good re-circulation of the solution is needed. The final contamination levels, after total oxide removal, are in accordance with limits indicated for unrestricted release of materials in some countries. The arising of the secondary waste is estimated. Decontamination of a 10 m 2 surface would typically produce 0.5 to 3.0 kg of dry waste, corresponding to 1.6 to 10 kg of concrete conditioned waste
Electrolytic decontamination of the 3013 inner can
International Nuclear Information System (INIS)
Wedman, D.E.; Nelson, T.O.; Rivera, Y.; Weisbrod, K.; Martinez, H.E.; Limback, S.
1998-01-01
Disposition of plutonium recovered from nuclear weapons or production residues must be stored in a manner that ensures safety. The criteria that has been established to assure the safety of stored materials for a minimum of 50 years is DOE-STD-3013. This standard specifies both the requirements for containment and furthermore specifies that the inner container be decontaminated to a level of ≤20 dpm/100 cm 2 swipable and ≤500 dpm/100 cm 2 direct alpha such that a failure of the outer containment barrier will have a lower probability of resulting in a spread of contamination. The package consists of an optional convenience (food pack) can, a welded type 304L stainless steel inner (primary) can, and a welded type 304L stainless steel outer (secondary) can. Following the welding process, the can is checked for leaks and then sent down the line for decontamination. Once decontaminated, the sealed primary can may be removed from the glove box line. Welding of the secondary container takes place outside the glove box line. The highly automated decontamination process that has been developed to support the packaging of Special Nuclear Materials is based on an electrolytic process similar to the wide spread industrial technique of electropolishing. The can is placed within a specially designed stainless steel fixture built within a partition of a glove box. The passage of current through this electrolytic cell results in a uniform anodic dissolution of the surface metal layers of the can. This process results in a rapid decontamination of the can. The electrolyte is fully recyclable, and the separation of the chromium from the actinides results in a compact, non RCRA secondary waste product
Vapor cell geometry effect on Rydberg atom-based microwave electric field measurement
Zhang, Linjie; Liu, Jiasheng; Jia, Yue; Zhang, Hao; Song, Zhenfei; Jia, Suotang
2018-03-01
The geometry effect of a vapor cell on the metrology of a microwave electric field is investigated. Based on the splitting of the electromagnetically induced transparency spectra of cesium Rydberg atoms in a vapor cell, high-resolution spatial distribution of the microwave electric field strength is achieved for both a cubic cell and a cylinder cell. The spatial distribution of the microwave field strength in two dimensions is measured with sub-wavelength resolution. The experimental results show that the shape of a vapor cell has a significant influence on the abnormal spatial distribution because of the Fabry–Pérot effect inside a vapor cell. A theoretical simulation is obtained for different vapor cell wall thicknesses and shows that a restricted wall thickness results in a measurement fluctuation smaller than 3% at the center of the vapor cell. Project supported by the National Key Research and Development Program of China (Grant Nos. 2017YFA03044200 and 2016YFF0200104), the National Natural Science Foundation of China (Grant Nos. 91536110, 61505099, and 61378013), and the Fund for Shanxi “331 Project” Key Subjects Construction, China.
Comparison of thorough decontamination techniques on dismantled pieces of a PWR reactor
International Nuclear Information System (INIS)
Klein, M.; Rahier, A.; Mandoki, R.; Ponnet, M.
1998-01-01
The decontamination experience gained during the BR3 dismantling project is developed. This started with the full system decontamination of the primary loop and was followed by R and D on thorough decontamination projects. First, a wet abrasive installation has been installed and is now in operation for the thorough cleaning of metallic pieces of simple geometry. Afterwards, the chemical cerium process has been developed. The results of the regeneration with ozone and with electrochemistry are presented in detail. The ozone regeneration process has been selected for the industrial installation of which the construction is foreseen in 1998. (author)
Decontamination systems information and research program. Quarterly report, April--June 1995
Energy Technology Data Exchange (ETDEWEB)
NONE
1995-07-01
West Virginia University (WVU) and the US Department of Energy Morgantown Energy Technology Center (DOE/METC) entered into a Cooperative Agreement on August 29, 1992 titled `Decontamination Systems Information and Research Programs`. Requirements stipulated by the Agreement require WVU to submit Technical Progress reports on a quarterly basis. This report contains the efforts of the fourteen research projects comprising the Agreement for the period April 1 to June 30, 1995. During this period three new projects have been funded by the Agreement. These projects are: (1) WERC National Design Contest, (2) Graduate Interns to the Interagency Environmental Technology Office under the National Science and Technology Council, and (3) WV High Tech Consortium.
Decontamination of some urban surfaces
International Nuclear Information System (INIS)
Thornton, E.W.
1988-04-01
The long-term consequences of external radiation dose to the public could be a cause for concern in the event of a severe accident at a nuclear power plant leading to the release of fission products to the atmosphere and subsequent contamination of buildings, roads and other components of the urban environment. This study has concentrated on the decontamination of building materials contaminated under wet conditions with soluble, ionic radiocaesium. Results are given on the decontamination of building materials contaminated without run-off, on the effects of waiting between contamination and decontamination and on the effect of pre-treatment with an ammonium salt solution. (author)
Decontamination and coating of lead
International Nuclear Information System (INIS)
Rankin, W.N.; Bush, S.P.; Lyon, C.E.; Walker, V.
1988-01-01
Technology is being developed to decontaminate lead used in shielding applications in contaminated environments for recycle as shieldings. Technology is also being developed to coat either decontaminated lead or new lead before it is used in contaminated environments. The surface of the coating is expected to be much easier to decontaminate than the original lead surface. If contamination becomes severely embedded in the coating and cannot be removed, it can be easily cut with a knife and removed from the lead. The used coating can be disposed of as radioactive (hot hazardous) waste. The lead can then be recoated for further use as a shielding material
Hairy skin exposure to VX in vitro: effectiveness of delayed decontamination.
Rolland, P; Bolzinger, M-A; Cruz, C; Josse, D; Briançon, S
2013-02-01
The chemical warfare agents such as VX represent a threat for both military and civilians, which involves an immediate need of effective decontamination systems. Since human scalp is usually unprotected compared to other body regions covered with clothes, it could be a preferential site of exposure in case of terrorist acts. The purpose of this study was to determine if skin decontamination could be efficient when performed more than 1h after exposure. In addition, the impact of hairs in skin contamination was investigated. By using in vitro skin models, we demonstrated that about 75% of the applied quantity of VX was recovered on the skin surface 2h after skin exposition, which means that it is worth decontaminating even if contamination occurred 2h before. The stratum corneum reservoir for VX was quickly established and persistent. In addition, the presence of hairs modified the percutaneous penetration of the nerve agent by binding of VX to hairs. Hair shaft has thus to be taken into account in the decontamination process. Reactive Skin Decontamination Lotion (RSDL) and Fuller's Earth (FE) were active in the skin decontamination 45min post-exposure, but RSDL was more efficient in reducing the amount of VX either in the skin or in the hair. Copyright © 2012 Elsevier Ltd. All rights reserved.
Low-waste electrochemical decontamination of stainless-steel surface
International Nuclear Information System (INIS)
Babain, V.A.; Smirnov, I.V.; Shadrin, A.Yu.; Firsin, N.G.; Zakharchuk, G.A.; Pavlov, A.B.; Shilov, V.V.
2002-01-01
An electrochemical decontamination method using a formic acid-based recycling electrolyte was proposed to remove firmly fixed contaminants from stainless-steel surfaces. The following provisions make for minimisation of the amounts of waste: (i) use of specially designed electrodes with vacuum removal of spent electrolyte; (ii) inter-cycle removal of radionuclides from the electrolyte by using an inorganic sorbent; (iii) periodic regeneration of the spent electrolyte. the dissolved metals (Fe, Cr, Ni) being transformed into acidic phosphates; (iv) solidification of residues arising from the regeneration of the electrolyte and spent sorbent into iron-phosphate ceramics. The technology and equipment developed were used for decontamination of a plutonium glove-box. The level of surface contamination was reduced 100-fold in two decontamination cycles. The depth of metal skimming was 1.5 μ for the ceiling and walls and 4.5 μ for the table top. Each square meter of stainless-steel surface provides about 100 g of solid radioactive waste in the form of iron-phosphate ceramic blocks
Decontamination and management of human remains following incidents of hazardous chemical release.
Hauschild, Veronique D; Watson, Annetta; Bock, Robert
2012-01-01
To provide specific guidance and resources for systematic and orderly decontamination of human remains resulting from a chemical terrorist attack or accidental chemical release. A detailed review and health-based decision criteria protocol is summarized. Protocol basis and logic are derived from analyses of compound-specific toxicological data and chemical/physical characteristics. Guidance is suitable for civilian or military settings where human remains potentially contaminated with hazardous chemicals may be present, such as sites of transportation accidents, terrorist operations, or medical examiner processing points. Guidance is developed from data-characterizing controlled experiments with laboratory animals, fabrics, and materiel. Logic and specific procedures for decontamination and management of remains, protection of mortuary affairs personnel, and decision criteria to determine when remains are sufficiently decontaminated are presented. Established procedures as well as existing materiel and available equipment for decontamination and verification provide reasonable means to mitigate chemical hazards from chemically exposed remains. Unique scenarios such as those involving supralethal concentrations of certain liquid chemical warfare agents may prove difficult to decontaminate but can be resolved in a timely manner by application of the characterized systematic approaches. Decision criteria and protocols to "clear" decontaminated remains for transport and processing are also provided. Once appropriate decontamination and verification have been accomplished, normal procedures for management of remains and release can be followed.
Diode-laser-based water vapor differential absorption lidar (DIAL) profiler evaluation
Spuler, S.; Weckwerth, T.; Repasky, K. S.; Nehrir, A. R.; Carbone, R.
2012-12-01
We are in the process of evaluating the performance of an eye-safe, low-cost, diode-laser-based, water vapor differential absorption lidar (DIAL) profiler. This class of instrument may be capable of providing continuous water vapor and aerosol backscatter profiles at high vertical resolution in the atmospheric boundary layer (ABL) for periods of months to years. The technology potentially fills a national long term observing facility gap and could greatly benefit micro- and meso-meteorology, water cycle, carbon cycle and, more generally, biosphere-hydrosphere-atmosphere interaction research at both weather and climate variability time scales. For the evaluation, the Montana State University 3rd generation water vapor DIAL was modified to enable unattended operation for a period of several weeks. The performance of this V3.5 version DIAL was tested at MSU and NCAR in June and July of 2012. Further tests are currently in progress with Howard University at Beltsville, Maryland; and with the National Weather Service and Oklahoma University at Dallas/Fort Worth, Texas. The presentation will include a comparison of DIAL profiles against meteorological "truth" at the aforementioned locations including: radiosondes, Raman lidars, microwave and IR radiometers, AERONET and SUOMINET systems. Instrument reliability, uncertainty, systematic biases, detection height statistics, and environmental complications will be evaluated. Performance will be judged in the context of diverse scientific applications that range from operational weather prediction and seasonal climate variability, to more demanding climate system process studies at the land-canopy-ABL interface. Estimating the extent to which such research and operational applications can be satisfied with a low cost autonomous network of similar instruments is our principal objective.
Decontamination evaluation based on radioactivity measurement instead of air dose rate
International Nuclear Information System (INIS)
Shozugawa, Katsumi
2013-01-01
Air dose rate at 1 m above the ground comes from gamma radiations emitted from vast area ranging over several ten meters of the contaminated field from the counter. After showing the actual example of the difference between air dose rate data and Cs 137 distribution map made by using a shielded NaI-scintillation counter within and around a contaminated sinkhole (a ditch or trench) near Fukushima Daiichi Nuclear Power Plants, the author proposes to make a decontamination program according to the radioactivity distribution measurement instead of air dose rate measurement. Furthermore, he explains some problems arising from a point and plane radiation source, and also difficulties accompanied by movement of Cs 137 atoms in the soils according to the absorption characteristics of the existing minerals but these are also important to consider for performing an effective decontamination. (S. Ohno)
Energy Technology Data Exchange (ETDEWEB)
Kaminski, Michael D. [Argonne National Lab. (ANL), Argonne, IL (United States); Mertz, Carol J. [Argonne National Lab. (ANL), Argonne, IL (United States); Kivenas, Nadia [Argonne National Lab. (ANL), Argonne, IL (United States); demmer, Rick [Idaho National Lab. (INL), Idaho Falls, ID (United States)
2016-01-01
Argonne National Laboratory (Argonne) developed a superabsorbing gel-based process (SuperGel) for the decontamination of cesium from concrete and other porous building materials. Here, we report on results that tested the gel decontamination technology on specific concrete and ceramic formulations from a coastal city in Southeast Asia, which may differ significantly from some U.S. sources. Results are given for the evaluation of americium and cesium sequestering agents that are commercially available at a reasonable cost; the evaluation of a new SuperGel formulation that combines the decontamination properties of cesium and americium; the variation of the contamination concentration to determine the effects on the decontamination factors with concrete, tile, and brick samples; and pilot-scale testing (0.02–0.09 m2 or 6–12 in. square coupons).
Performance Evaluation of An Innovative-Vapor- Compression-Desalination System
Directory of Open Access Journals (Sweden)
Mirna R. Lubis
2012-04-01
Full Text Available Two dominant desalination methods are reverse osmosis (RO and multi-stage flash (MSF. RO requires large capital investment and maintenance, whereas MSF is too energy-intensive. Innovative system of vapor compression desalination is proposed in this study. Comprehensive mathematics model for evaporator is also described. From literature study, it is indicated that very high overall-heat-transfer coefficient for evaporator can be obtained at specific condition by using dropwise condensation in the steam side, and pool boiling in the liquid side. Smooth titanium surface is selected in order to increase dropwise condensation, and resist corrosion. To maximize energy efficiency, a cogeneration scheme of a combined cycle consisting of gas turbine, boiler heat recovery, and steam turbine that drivescompressor is used. The resource for combined cycle is relatively too high for the compressor requirement. Excess power can be used to generate electricity for internal and/or externalconsumptions, and sold to open market. Four evaporator stages are used. Evaporator is fed by seawater, with assumption of 3.5% salt contents. Boiling brine (7% salt is boiled in low pressure side of the heat exchanger, and condensed vapor is condensed in high pressure side of the heat exchanger. Condensed steam flows at velocity of 1.52 m/s, so that it maximize the heat transfer coefficient. This unit is designed in order to produce 10 million gallon/day, and assumed it is financed with 5%, 30 years of passive obligation. Three cases are evaluated in order to determine recommended condition to obtain the lowest fixed capital investment. Based on the evaluation, it is possible to establish four-stage unit of mechanical vapor compression distillation with capital $31,723,885.
International Nuclear Information System (INIS)
Kawasaki, Kota
2016-01-01
This study discusses opinions of 11 municipalities in Fukushima Prefecture designated as Special Decontamination Area as of the end of September 2015, about four and a half years afters the Fukushima Daiichi Nuclear Power Plant accident. This study shows that (1) more than half of the municipalities recognize that decontamination activities of the national government which is responsible for decontamination in Special Decontamination Area are inadequate, (2) most municipalities recognize that residents cannot live their lives with a sense of safety and security unless air radiation dose is reduced to the level before the accident or less than 0.23 μSv/h, (3) many municipalities recognize that residents will not be able to live their lives with a sense of safety and security even if the national government implements decontamination, (4) municipalities points out 'decontamination of forests or rivers and reconsideration of decontamination methods of forests or rivers', 'securement and maintenance of temporary storage site' and 'setting forth a numeric target concerning decontamination and implementation of additional decontamination after the first decontamination' as issues for the promotion of decontamination, and (5) all the municipalities recognize that that there are a lot of problems concerning the installation of interim storage facilities by the national government. (author)
Electrode design for soil decontamination with Radio-Frequency heating
Energy Technology Data Exchange (ETDEWEB)
Roland, U.; Holzer, F.; Kraus, M.; Trommler, U.; Kopinke, F.D. [Helmholtz Centre for Environmental Research - UFZ, Department of Environmental Engineering, Leipzig (Germany)
2011-10-15
Radio-frequency heating to enhance soil decontamination requires adjusted solutions for the electrode design depending on scale and remediation technique. Parallel plate electrodes provide widely homogeneous field and temperature distributions and are, therefore, most suitable for supporting biodegradation processes. For thermally enhanced soil vapor extraction, certain temperature gradients can be accepted and, therefore, the less-demanding geometry of rod-shaped electrodes is usually applied. For electrode lengths of some meters, a design with an air gap has to be used in order to focus heating to the desired depth. Perforated rod electrodes may be simultaneously employed as extraction wells. Placing an oxidation catalyst in situ within the electrodes is an option for handling of highly loaded air flows. Coaxial antenna may be utilized to selectively heat soil compartments far from the surface of the soil. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)
A low-cost vaporization-atomization system for atomic absorption spectrometry
International Nuclear Information System (INIS)
Bruhn F, C.G.; Ambiado V, F.; Woerner V, R.
1990-01-01
A low-cost vaporization-atomization system for atomic absorption spectrometry is developed as an alternative to the use of a graphite furnace in electrothermal atomic absorption spectrometry. (Author)
DNA decontamination methods for internal quality management in clinical PCR laboratories.
Wu, Yingping; Wu, Jianyong; Zhang, Zhihui; Cheng, Chen
2018-03-01
The polymerase chain reaction (PCR) technique, one of the most commonly applied methods in diagnostic and molecular biology, has a frustrating downside: the occurrence of false-positive signals due to contamination. In previous research, various DNA decontamination methods have been developed to overcome this limitation. Unfortunately, the use of random or poorly focused sampling methods for monitoring air and/or object surfaces leads to the incomplete elimination during decontamination procedures. We herein attempted to develop a novel DNA decontamination method (environmental surveillance, including surface and air sampling) and quality management program for clinical molecular diagnostic laboratories (or clinical PCR laboratories). Here, we performed a step-by-step evaluation of current DNA decontamination methods and developed an effective procedure for assessing the presence of decontaminating DNA via PCR analysis. Performing targeted environmental surveillance by sampling, which reached optimal performance over 2 weeks, and the decontamination process had been verified as reliable. Additionally, the process was validated to not affect PCR amplification efficiency based on a comparative study. In this study, effective guidelines for DNA decontamination were developed. The method employed ensured that surface DNA contamination could be effectively identified and eliminated. Furthermore, our study highlighted the importance of overall quality assurance and good clinical laboratory practices for preventing contamination, which are key factors for compliance with regulatory or accreditation requirements. Taken together, we provided the evidence that the presented scheme ranged from troubleshooting to the elimination of surface contamination, could serve as critical foundation for developing regular environmental surveillance guidelines for PCR laboratories. © 2017 Wiley Periodicals, Inc.
Jacquet, Pauline; Daudé, David; Bzdrenga, Janek; Masson, Patrick; Elias, Mikael; Chabrière, Eric
2016-05-01
Organophosphorus chemicals are highly toxic molecules mainly used as pesticides. Some of them are banned warfare nerve agents. These compounds are covalent inhibitors of acetylcholinesterase, a key enzyme in central and peripheral nervous systems. Numerous approaches, including chemical, physical, and biological decontamination, have been considered for developing decontamination methods against organophosphates (OPs). This work is an overview of both validated and emerging strategies for the protection against OP pollution with special attention to the use of decontaminating enzymes. Considerable efforts have been dedicated during the past decades to the development of efficient OP degrading biocatalysts. Among these, the promising biocatalyst SsoPox isolated from the archaeon Sulfolobus solfataricus is emphasized in the light of recently published results. This hyperthermostable enzyme appears to be particularly attractive for external decontamination purposes with regard to both its catalytic and stability properties.
International Nuclear Information System (INIS)
Oh, Won Zin; Lee, K. W.; Won, H. J.; Jung, C. H.; Choi, W. K.; Kim, G. N.
2001-08-01
A. Decontamination Technology Development of Uranium Conversion Facility. Understanding of uranium conversion facility and related decontamination technologies, and analysis of current status of decontamination technologies. Establishment of the objective and research items of the middle and long term R and D project. Discussion of the erformance plan and about the methodology for connection with the project of environmental restoration of uranium conversion facility B. Treatment Technology Development of Uranium Sludge Analysis of the domestic and overseas research development status. Suggestion of treatment methodology of uranium slurry and cooperative R and D among industries, universities and research institute. Establishment of the objective and research items of the middle and long term R and D project. Discussion about the performance plan and about the methodology for connection with the project of environmental restoration of uranium conversion facility C. Decommissioning Technology Development Analysis of the domestic and overseas research development status and the overview of decommissioning technologies. Establishment of the objective and research items of the middle and long term R and D project. Discussion about the performance plan and about the methodology for connection with the project of TRIGA decommissioning D. Evaluation of KAERI Soil Decontamination Technology. Evaluation of soil decontamination process and the liquid decontamination waste treatment technology. Performance of soil decontamination test using solvent flushing test equipment for evaluation of residual radioactivity after decontami- nation and modeling of the results
Energy Technology Data Exchange (ETDEWEB)
Oh, Won Zin; Lee, K. W.; Won, H. J.; Jung, C. H.; Choi, W. K.; Kim, G. N
2001-08-01
A. Decontamination Technology Development of Uranium Conversion Facility. Understanding of uranium conversion facility and related decontamination technologies, and analysis of current status of decontamination technologies. Establishment of the objective and research items of the middle and long term R and D project. Discussion of the erformance plan and about the methodology for connection with the project of environmental restoration of uranium conversion facility B. Treatment Technology Development of Uranium Sludge Analysis of the domestic and overseas research development status. Suggestion of treatment methodology of uranium slurry and cooperative R and D among industries, universities and research institute. Establishment of the objective and research items of the middle and long term R and D project. Discussion about the performance plan and about the methodology for connection with the project of environmental restoration of uranium conversion facility C. Decommissioning Technology Development Analysis of the domestic and overseas research development status and the overview of decommissioning technologies. Establishment of the objective and research items of the middle and long term R and D project. Discussion about the performance plan and about the methodology for connection with the project of TRIGA decommissioning D. Evaluation of KAERI Soil Decontamination Technology. Evaluation of soil decontamination process and the liquid decontamination waste treatment technology. Performance of soil decontamination test using solvent flushing test equipment for evaluation of residual radioactivity after decontami- nation and modeling of the results.
Vaporization of irradiated droplets
International Nuclear Information System (INIS)
Armstrong, R.L.; O'Rourke, P.J.; Zardecki, A.
1986-01-01
The vaporization of a spherically symmetric liquid droplet subject to a high-intensity laser flux is investigated on the basis of a hydrodynamic description of the system composed of the vapor and ambient gas. In the limit of the convective vaporization, the boundary conditions at the fluid--gas interface are formulated by using the notion of a Knudsen layer in which translational equilibrium is established. This leads to approximate jump conditions at the interface. For homogeneous energy deposition, the hydrodynamic equations are solved numerically with the aid of the CON1D computer code (''CON1D: A computer program for calculating spherically symmetric droplet combustion,'' Los Alamos National Laboratory Report No. LA-10269-MS, December, 1984), based on the implict continuous--fluid Eulerian (ICE) [J. Comput. Phys. 8, 197 (1971)] and arbitrary Lagrangian--Eulerian (ALE) [J. Comput. Phys. 14, 1227 (1974)] numerical mehtods. The solutions exhibit the existence of two shock waves propagating in opposite directions with respect to the contact discontinuity surface that separates the ambient gas and vapor
Carricajo, A.; Fonsale, N.; Vautrin, A. C.; Aubert, G.
2001-01-01
A total of 52 mycobacterial isolates were recovered from 1,197 clinical specimens decontaminated by a sodium dodecyl (lauryl) sulfate (SDS)-NaOH protocol. Of these, 94% were recovered with the BacT/Alert 3D system (Organon Teknika, Durham, N.C.) and 79% were recovered on Löwenstein-Jensen (LJ) medium. Mean times to detection of organisms of the Mycobacterium tuberculosis complex (n = 47) were 22.8 days with LJ medium and 16.2 days with the system. The BacT/Alert 3D system is a rapid and efficient detection system which can be used with an SDS-NaOH decontamination procedure. PMID:11574623
Physicochemical characteristics of PFC surfactants for dry decontamination
Energy Technology Data Exchange (ETDEWEB)
Oh, Won Jin; Lee, Chi Woo [Korea University, Seoul (Korea)
2001-04-01
Even the trace amount of the used nuclear fuels of high radioactivity are hazardous to the earth and humans. Perfluorocarbons and perfluorocarbon surfactants are emerging to be efficient chemicals in the dry decontamination process of the used fuels of high radioactivity. The theme was undertaken to increase the knowledge on perfluorocarbon surfactants to develop the perfluorocarbon system in the dry decontamination process in Korea. Several cationic and anionic pfc surfactants were synthesized. Effects of pfc surfactants on electrochemical etching of silicon were investigated to form porous silicons. Forces were measured between silicon surfaces and AFM tip in the absence and presence of pfc surfactants. 7 refs., 10 figs. (Author)
DEFF Research Database (Denmark)
Thomsen, Kaj; Iliuta, Maria Cornelia; Rasmussen, Peter
2004-01-01
The Extended UNIQUAC model for electrolyte solutions is an excess Gibbs energy function consisting of a Debye-Huckel term and a term corresponding to the UNIQUAC equation. For vapor-liquid equilibrium calculations, the fugacities of gas-phase components are calculated with the Soave-Redlich-Kwong......The Extended UNIQUAC model for electrolyte solutions is an excess Gibbs energy function consisting of a Debye-Huckel term and a term corresponding to the UNIQUAC equation. For vapor-liquid equilibrium calculations, the fugacities of gas-phase components are calculated with the Soave...... solid-liquid-vapor equilibrium and thermal property data for strongly non-ideal systems. In this work, the model is extended to aqueous salt systems containing higher alcohols. The calculations are based on an extensive database consisting of salt solubility data, vapor liquid equilibrium data...
Experiment on electrolysis decontamination of stainless steel pipes
International Nuclear Information System (INIS)
Wang Dongwen; Dou Tianjun; Zhao Yujie
2004-01-01
A new electrolytic decontamination method used metal balls as conducting anode was investigated. The influences of current density, solution property and diameter of pipes on efficiency of electrolytic decontamination were examined and the efficiency of this method was compared with that of common electrolytic method under the same experimental conditions. Decontamination of samples of stainless steel pipes contaminated by plutonium was performed. Experimental results indicate that decontamination of stainless steel pipes contaminated by plutonium can be achieved at the optimum conditions of greater than 0.2 A·cm -2 current density, 5% sulfuric acid electrolyte and 5 min electrolysis. This method can be used in the decontamination of a wide variety of decommissioned metal materials. (author)
Loop cleanup with redox decontamination technique
International Nuclear Information System (INIS)
Ren Xian Wen; Zhang Yuan
1998-01-01
The corrosion rate of stainless steel in nitric acid solution will be enhanced by existence of Ce 4+ . The goal of this study is to develop a circular decontamination process in medium of nitric acid, in order to use it in a loop clean up. That needs a specially designed electrolytic cell to oxidize the Ce 3+ into Ce 4+ . This regenerator's structure should be simple and easy to operate, and can meet the requirements of practical decontamination operation. The concentration of Ce 4+ in the nitric acid solution was selected to provide a suitable corrosion rate to contaminated stainless steel. The total concentration of cerium (III+IV) was also optimized to ensure that the regeneration rate of Ce 4+ could satisfy the consumption rate of Ce 4+ during decontaminating process. The operation parameters were selected strictly on the basis of our experimental results, so that the regeneration rate of Ce 4+ can be higher reasonably in proper operation conditions and not arise any problem related to safety of operation and nuclear aspects. It is considered that this decontamination process could be applied into either decommissioning or maintenance stage of nuclear facilities. The concentration of Ce 4+ and temperature are the main factors for corrosion rate, other factors should also be considered during decision of decontamination process. With the regenerator developed under contract No 7959/RB could obtain sufficient decontamination factors, when use following conditions: concentration of Ce 4+ is higher than 0.2 mol/1, the total concentration of cerium (III+IV) is higher than 0.4 mol/1, concentration of nitric acid is higher than 2 mol/1, temperature of decontamination operation is within 25 deg. C - 40 deg. C and temperature of regeneration is within 40 deg C - 50 deg.C
Mesoporous titanium-manganese dioxide for sulphur mustard and soman decontamination
Energy Technology Data Exchange (ETDEWEB)
Stengl, Vaclav, E-mail: stengl@iic.cas.cz [Department of Solid State Chemistry, Institute of Inorganic Chemistry AS CR v.v.i., 250 68 Rez (Czech Republic); Bludska, Jana [Department of Solid State Chemistry, Institute of Inorganic Chemistry AS CR v.v.i., 250 68 Rez (Czech Republic); Oplustil, Frantisek; Nemec, Tomas [Military Technical Institute of Protection Brno, Veslarska 230, 628 00 Brno (Czech Republic)
2011-11-15
Highlights: {yields} New nano-dispersive materials for warfare agents decontamination. {yields} 95% decontamination activities for sulphur mustard. {yields} New materials base on titanium and manganese oxides. -- Abstract: Titanium(IV)-manganese(IV) nano-dispersed oxides were prepared by a homogeneous hydrolysis of potassium permanganate and titanium(IV) oxo-sulphate with 2-chloroacetamide. Synthesised samples were characterised using Brunauer-Emmett-Teller (BET) surface area and Barrett-Joiner-Halenda porosity (BJH), X-ray diffraction (XRD), infrared spectroscopy (IR), and scanning electron microscopy (SEM). These oxides were taken for an experimental evaluation of their reactivity with sulphur mustard (HD or bis(2-chloroethyl)sulphide) and soman (GD or (3,3'-dimethylbutan-2-yl)-methylphosphonofluoridate). Mn{sup 4+} content affects the decontamination activity; with increasing Mn{sup 4+} content the activity increases for sulphur mustard and decreases for soman. The best decontamination activities for sulphur mustard and soman were observed for samples TiMn{sub 3}7 with 18.6 wt.% Mn and TiMn{sub 5} with 2.1 wt.% Mn, respectively.
Fabrication of remote steam atomized scrubbers for DWPF off-gas system
International Nuclear Information System (INIS)
Nielsen, M.G.; Lafferty, J.D.
1988-01-01
The defense waste processing facility (DWPF) is being constructed for the purpose of processing high-level waste from sludge to a vitrified borosilicate glass. In the operation of continuous slurry-fed melters, off-gas aerosols are created by entrainment of feed slurries and the vaporization of volatile species from the molten glass mixture. It is necessary to decontaminate these aerosols in order to minimize discharge of airborne radionuclide particulates. A steam atomized scrubber (SAS) has been developed for DWPF which utilizes a patented hydro- sonic system gas scrubbing method. The Hydro-Sonic System utilizes a steam aspirating-type venturi scrubber that requires very precise fabrication tolerances in order to obtain acceptable decontamination factors. In addition to the process-related tolerances, precision mounting and nozzle tolerances are required for remote service at DWPF
Method of decontaminating radioactive-contaminated instruments
Energy Technology Data Exchange (ETDEWEB)
Urata, M; Fujii, M; Kitaguchi, H
1982-03-29
Purpose: To enable safety processing of liquid wastes by recovering radioactive metal ions remaining in the electrolytes after the decontamination procedure thereby decreasing the radioactivity. Method: In a decontamination tank containing electrolytes consisting of diluted hydrochloric acid and diluted sulfuric acid, are provided a radioactive contaminated instrument connected to an anode and a collector electrode made of stainless steel connected to a cathode respectively. Upon applying electrical current, the portion of the mother material to be decontaminated is polished electrolytically into metal ions and they are deposited as metal on the collection electrode. After completion of the decontamination, an ultrasonic wave generator is operated to strip and remove the oxide films. Thereafter, the anode is replaced with the carbon electrode and electrical current is supplied continuously, whereby the remaining metal ions are deposited and recovered as the metal on the collection electrode.
A microcantilever-based alcohol vapor sensor-application and response model
DEFF Research Database (Denmark)
Jensenius, Henriette; Thaysen, Jacob; Rasmussen, Anette Alsted
2000-01-01
A recently developed microcantilever probe with integrated piezoresistive readout has been applied as a gas sensor. Resistors, sensitive to stress changes, are integrated on the flexible cantilevers. This makes it possible to monitor the cantilever deflection electrically and with an integrated...... is a direct measure of the molecular concentration of alcohol vapor. On the basis of the model the detection limit of this cantilever-based sensor is determined to be below 10 ppm for alcohol vapor measurements. Furthermore, the time response of the cantilever can be used to distinguish between different...
Application of a novel decontamination process using gaseous ozone
Energy Technology Data Exchange (ETDEWEB)
Moat, J.; Shone, J.; Upton, M. [Manchester Univ., School of Medecine, Manchester (United Kingdom). Medical Microbiology, Translation Medicine; Cargill, J. [Old Medical School, Leeds (United Kingdom). Dept. of Microbiology
2009-08-15
Hospital surfaces that are touched regularly by staff carry bacterial spores and pathogens. Environmental disinfection of health care facilities is an important aspect of infection control. This paper presented a recent innovation aimed at improving hospital hygiene and decontamination of laboratory equipment. The vapour- and gas-based treatment was developed to penetrate rooms or soft furnishings and reach places inaccessible by conventional approaches. Surfaces seeded with a range of vegetative cells and spores of bacteria of clinical relevance were decontaminated using the ozone-based treatment. The efficiency of the approach for room sanitization was also evaluated. A quenching agent was used to rapidly reduce ozone concentrations to safe levels allowing treatment times of less than 1 h for most of the organisms tested. Bacteria was seeded onto agar plates and solid surfaces. Reductions in bacterial load of greater than 3 log values were then recorded for a number of organisms including Escherichia coli and methicillin-resistant Staphylococcus aureus. Application of the process in a 30 m{sup 3} room showed similar reductions in viable counts for these organisms and for Clostridium difficile spores. It was concluded that ozone-based decontamination of healthcare environments could prove to be a highly cost-effective intervention. 35 refs., 1 tab., 3 figs.
Water vapor permeabilities through polymers: diffusivities from experiments and simulations
International Nuclear Information System (INIS)
Seethamraju, Sindhu; Ramamurthy, Praveen Chandrashekarapura; Madras, Giridhar
2014-01-01
This study experimentally determines water vapor permeabilities, which are subsequently correlated with the diffusivities obtained from simulations. Molecular dynamics (MD) simulations were used for determining the diffusion of water vapor in various polymeric systems such as polyethylene, polypropylene, poly (vinyl alcohol), poly (vinyl acetate), poly (vinyl butyral), poly (vinylidene chloride), poly (vinyl chloride) and poly (methyl methacrylate). Cavity ring down spectroscopy (CRDS) based methodology has been used to determine the water vapor transmission rates. These values were then used to calculate the diffusion coefficients for water vapor through these polymers. A comparative analysis is provided for diffusivities calculated from CRDS and MD based results by correlating the free volumes. (paper)
Salt decontamination demonstration test results
International Nuclear Information System (INIS)
Snell, E.B.; Heng, C.J.
1983-06-01
The Salt Decontamination Demonstration confirmed that the precipitation process could be used for large-scale decontamination of radioactive waste sale solution. Although a number of refinements are necessary to safely process the long-term requirement of 5 million gallons of waste salt solution per year, there were no observations to suggest that any fundamentals of the process require re-evaluation. Major accomplishments were: (1) 518,000 gallons of decontaminated filtrate were produced from 427,000 gallons of waste salt solution from tank 24H. The demonstration goal was to produce a minimum of 200,000 gallons of decontaminated salt solution; (2) cesium activity in the filtrate was reduced by a factor of 43,000 below the cesium activity in the tank 24 solution. This decontamination factor (DF) exceeded the demonstration goal of a DF greater than 10,000; (3) average strontium-90 activity in the filtrate was reduced by a factor of 26 to less than 10 3 d/m/ml versus a goal of less than 10 4 d/m/ml; and (4) the concentrated precipitate was washed to a final sodium ion concentration of 0.15 M, well below the 0.225 M upper limit for DWPF feed. These accomplishments were achieved on schedule and without incident. Total radiation exposure to personnel was less than 350 mrem and resulted primarily from sampling precipitate slurry inside tank 48. 3 references, 6 figures, 2 tables
Radioactive Decontamination by Strippable Paint
International Nuclear Information System (INIS)
Chantaraparprachoom, N.; Mishima, K.
1998-01-01
The strippable paint, one of the adhesion method, is to decontaminate solid surface of materials or/and a large area. Two kinds of specimen planchet, SUS 304 stainless steel and polycarbonate plastic, contaminated with radioactive 137 Cs were studied under various conditions. It included surface bottom types, the flat and convex concentric circle type, normal condition at room temperature and overheat condition (∼80 degree celsius). This method used coating paints which contains some elements to have a reaction with radioactive materials selectively. ALARA-Decon clear, Rempack-X200 clear, JD-P5-Mrs.Coat and Pro-Blue-color guard were selected to use as the coating paints. The contaminated surface was coated by the strippable paint under the optimum time, followed by peeling the paint seal. The Rempack-X200 showed the best result, the highest decontamination efficiency which are about 99-100% for all conditions of specimens. The JD-P5 and ALARA-Decon showed good results, which are 98-99% decontamination efficiency for the normal condition set of specimens and about 94-97% for the overheat set of specimens. They can decontaminate polycarbonate specimens better than stainless steel specimens. The Pro-Blue-color guard showed the lowest decontamination efficiency of which 60% for polycarbonate specimens at normal condition and 40%, 30% for stainless steel specimens at normal and overheat conditions respectively. There was no effects of surface bottom types significantly
Solid waste handling and decontamination facility
International Nuclear Information System (INIS)
Lampton, R.E.
1979-01-01
The Title 1 design of the decontamination part of the SWH and D facility is underway. Design criteria are listed. A flowsheet is given of the solid waste reduction. The incinerator scrubber is described. Design features of the Gunite Tank Sludge Removal and a schematic of the sluicer, TV camera, and recirculating system are given. 9 figures
Electropolishing as a decontamination process: progress and applications
International Nuclear Information System (INIS)
Allen, R.P.; Arrowsmith, H.W.; Charlot, L.A.; Hooper, J.L.
1978-04-01
Research studies demonstrated the ability of electropolishing to reduce the radiation levels of steel tools and stainless steel vacuum system components, which were heavily contaminated with plutonium oxide, from 1 million dis/min x 100 cm 2 to background in less than 10 min. Other examples of objects that have been decontaminated within minutes using electropolishing include hot cell manipulator assemblies, analytical instrument components, laboratory transfer containers, offsite shipping containers, fission product storage capsules, laboratory animal cages, and nuclear reactor process tube components. One of the major activities of this research has been the establishment and intensive operation of a 400-gal immersion electropolishing system. Progress has also been made in developing in situ electropolishing techniques that can be used to decontaminate metallic surfaces that cannot readily be transported to or immersed in a conventional electropolishing tank. Sectioning/pretreatment studies are under way to develop and demonstrate optimum disassembly, sectioning, surface preparation, and gross contamination removal procedures. Arc saw, plasma arc torch, and explosive cutting techniques are being evaluated in terms of the thickness and characteristics of the disturbed metal layer. Some of the pretreatment methods under consideration for removal of paint, grease, corrosion layers, and gross contamination include vibratory finishing, ultrasonics, dry and liquid abrasive blasting, and high-pressure spray systems. Other supporting studies are also in progress to provide a sound technical basis for scale-up and widespread application of this new decontamination process. 44 figures
Uranium/water vapor reactions in gaseous atmospheres
International Nuclear Information System (INIS)
Jackson, R.L.; Condon, J.B.; Steckel, L.M.
1977-07-01
Experiments have been performed to determine the effect of varying humidities, gaseous atmospheres, and temperatures on the uranium/water vapor reaction. A balance, which allowed continuous in-system weighings, was used to determine the rates of the uranium/water vapor reactions at water vapor pressures of 383, 1586, and 2853 Pa and at temperatures of 80, 100, and 150 0 C in atmospheres of hydrogen, argon, or argon/oxygen mixtures. Based on rate data, the reactions were characterized as hydriding or nonhydriding. Hydriding reactions were found to be preferred in moist hydrogen systems at the higher temperatures and the lower humidities. The presence of hydrogen in hydriding systems was found to initially inhibit the reaction, but causes an acceleration of the rate in the final stages. In general, reaction rates of hydriding systems approached the hydriding rates calculated and observed in dry hydrogen. Hydriding and nonhydriding reaction rates showed a positive correlation to temperature and water vapor pressure. Final reaction rates in moist argon/oxygen mixtures of 1.93, 4.57, and 9.08 mole percent oxygen were greater than the rates observed in moist hydrogen or argon. Final reaction rates were negatively correlated to the oxygen concentration
International Nuclear Information System (INIS)
McVeety, B.D.; Evans, J.C.; Clauss, T.W.; Pool, K.H.
1996-05-01
This report describes the results of vapor samples taken from the headspace of waste storage tank 241-SX-102 (Tank SX-102) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed under the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5046. Samples were collected by WHC on July 19, 1995, using the vapor sampling system (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace
International Nuclear Information System (INIS)
Ligotke, M.W.; Pool, K.H.; Clauss, T.W.
1996-05-01
This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-103 (Tank AX-103) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) by the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5029. Samples were collected by WHC on June 21, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace
International Nuclear Information System (INIS)
Pool, K.H.; Clauss, T.W.; Evans, J.C.; McVeety, B.D.
1996-05-01
This report describes the results of vapor samples taken from the headspace of waste storage tank 241-AX-101 (Tank AX-101) at the Hanford Site in Washington State. Pacific Northwest National Laboratory (PNNL) contracted with Westinghouse Hanford Company (WHC) to provide sampling devices and analyze samples for inorganic and organic analytes collected from the tank headspace and ambient air near the tank. The analytical work was performed by the PNNL Vapor Analytical Laboratory (VAL) under the Tank Vapor Characterization Project. Work performed was based on a sample and analysis plan (SAP) prepared by WHC. The SAP provided job-specific instructions for samples, analyses, and reporting. The SAP for this sample job was open-quotes Vapor Sampling and Analysis Planclose quotes, and the sample job was designated S5028. Samples were collected by WHC on June 15, 1995, using the Vapor Sampling System (VSS), a truck-based sampling method using a heated probe inserted into the tank headspace
A study on dry decontamination using ion exchange polymer
International Nuclear Information System (INIS)
Jung, Ki Jung; Ahn, Byung Gil
1997-12-01
Through the project of A study on dry decontamination using ion exchange polymer , the followings were investigated. 1. Highly probable decontamination technologies for the decontamination were investigated. 2. Development of gel type decontamination agent using ion-exchange resin powder (mixed type) as an ion exchanger. 3. Manufacturing of contaminated specimens (5 kinds) with Cs-137 solution and dust / Cs-137 solution. 4. Decontamination performance evaluation of the manufactured agent. 5. Analysis of composition (XRF) and the structure of surface of specimens (optic micrography). (author). 20 refs., 11 figs
DEFF Research Database (Denmark)
Radfarnia, H.R.; Ghotbi, C.; Taghikhani, V.
2005-01-01
The main purpose of this work is to present a free-volume combinatorial term in predicting vapor-liquid equilibrium (VLE) and solid-liquid equilibrium (SLE) of polymer/solvent and light and heavy hydrocarbon/hydrocarbon mixtures. The proposed term is based on a modification of the original Freed ...
Decontamination training: with and without virtual reality simulation.
Farra, Sharon Lee; Smith, Sherrill; Gillespie, Gordon Lee; Nicely, Stephanie; Ulrich, Deborah L; Hodgson, Eric; French, DeAnne
2015-01-01
Nurses must be prepared to care for patients following a disaster, including patients exposed to hazardous contaminants. The purpose of this study was to examine the use of virtual reality simulation (VRS) to teach the disaster-specific skill of decontamination. A quasi-experimental design was used to assign nursing students from 2 baccalaureate nursing programs to 1 of 2 groups to learn the disaster skill of decontamination-printed written directions or VRS. Performance, knowledge, and self-efficacy were outcome measures. Although students in the treatment group had significantly lower performance scores than the control group (p = 0.004), students taking part in VRS completed the skill in a significantly shorter amount of time (p = 0.008). No significant group differences were found for self-efficacy (p = 0.172) or knowledge (p = 0.631). However, students in the VRS treatment group reported high levels of satisfaction with VRS as a training method. The disaster-specific skill of decontamination is a low-volume, high-risk skill that must be performed with accuracy to protect both exposed patients and providers performing decontamination. As frontline providers for casualties following a disaster event, emergency nurses must be prepared to perform this skill when needed. Preparation requires cost-effective, timely, and evidence-based educational opportunities that promote positive outcomes. Further investigation is needed to determine the benefits and long-term effects of VRS for disaster education.
Decontamination of 125I in Medical Laboratory
International Nuclear Information System (INIS)
Abdel Geleel, M.; Tawfeek, A.A.
2009-01-01
A radiological laboratory for diagnoses was contaminated by 125 I. A large-scale survey of gamma-radiation has been made in different locations of the floors and walls of the lab to determine the contaminated area and its activity. The activity level before decontamination for the wall and floor was 1400 and 2000 Bq/cm 2 respectively. Decontamination was carried out by using ethyl alcohol, potassium permanganate, ethylene diamine tetracetic acid and tissue papers. Decontamination factor has been calculated and it was 175 and 200 for the wall and floor respectively. D and D computer code has been used to calculate Total Effective Dose Equivalent (TEDE). TEDE from the wall and floor before decontamination were 3.05 and 4.35 ( mSv/yr ) while after decontamination were 18 and 23μSv/yr respectively. These results are lower than the Egyptian and the international regulations (10 mSv/y for the public ) according to International Atomic Energy agency, IAEA, Safety Series, SS, no. 115 (1994).
Decontamination Systems Information and Research Program: Quarterly report, July--September 1994
International Nuclear Information System (INIS)
1994-11-01
West Virginia University (WVU) and the US DOE Morgantown Energy Technology Center (METC) entered into a Cooperative Agreement on August 29, 1992 entitled ''Decontamination Systems Information and Research Programs'' (DOE Instrument No.: DE-FC21-92MC29467). Stipulated within the Agreement is the requirement that WVU submit to METC a series of Technical Progress Reports on a quarterly basis. This report comprises the eighth Quarterly Technical Progress Report for the Agreement. This report reflects the progress and/or efforts performed on the 16 technical projects encompassed by the Agreement for the period of July 1 through September 30, 1994. These projects focus on the following: Bio-remediation of organic compounds, heavy metals, and radionuclides; miscellaneous remediation technologies; instrumentation; and technology assessments
EDF guide book for decontamination at power plant
International Nuclear Information System (INIS)
Glorennec, C.; Bemer, J.P.
1988-01-01
Nuclear Power Plant components or equipment often need to be more or less decontaminated before undergoing maintenance. In order to coordinate the activities of the different maintenance specialists belonging to the corporate or site organizations, the management of EDF/Nuclear and Fossil Division has created a decontamination task force. One of the objectives of this task force was to elaborate the present Guide Book for Decontamination at Power Plants. This paper provides assistance to nuclear plants operators in the very specific field of decontamination
Decontamination of Soil Contaminated with Bacillus anthracis ...
Technical Brief This technical summary will provide decontamination personnel rapid access to information on which decontamination approaches are most effective for soils contaminated with B anthracis.
Energy Technology Data Exchange (ETDEWEB)
Jung, Jun Young; Park, Sang Yoon; Won, Hui Jun; Kim, Seon Byeong; Choi, Wang Kyu; Moon, Jei Kwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)
2013-10-15
An alkaline permanganate (AP) or nitric permanganate (NP) oxidative phase has been generally used to dissolve the chromium-rich oxide. AP is advantageous for the corrosion resistance, but increases the volume of secondary waste during the decontamination procedure. On the other hand, NP has a high corrosion rate but reduces secondary waste. For the safe use of an oxidative decontamination solution with high corrosive resistance and less amount of secondary waste are required. In this study, we modified NP oxidative decontamination solution by adding Cu{sup 2+} to reduce the corrosion rate. To evaluate the general corrosion characteristics, we measured the weight losses of selected specimens in an NP(Cu) and other solutions. The localized corrosion was observed using an optical microscope (OM). To compare the decontamination performance, we measured the contact dose rate of specimens treated in NP-HYBRID and NP(Cu)-HYBRID systems. The reduced corrosion characteristics of the Inconel-600 specimen in a NP(Cu) oxidative solution was observed in terms of generalized corrosion as well as localized corrosion. Less corrosion characteristics do not affect the performance of the overall decontamination compared to the NP-HYBRID process. Therefore, our results support that the NP(Cu)-HYBRID decontamination process is appropriate for the decontamination of the primary coolant system in a nuclear reactor.