WorldWideScience

Sample records for valves phase ii

  1. High Temperature, High Frequency Fuel Metering Valve, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  2. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  3. Low-Mass VOST Valve, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Two low-mass, linear throttling, high-efficiency, leak-proof cryogenic valves of diameters 1/2" and 4" will be built and tested. Based upon cryogenically-proven...

  4. Prediction of two-phase choked-flow through safety valves

    International Nuclear Information System (INIS)

    Arnulfo, G; Bertani, C; De Salve, M

    2014-01-01

    Different models of two-phase choked flow through safety valves are applied in order to evaluate their capabilities of prediction in different thermal-hydraulic conditions. Experimental data available in the literature for two-phase fluid and subcooled liquid upstream the safety valve have been compared with the models predictions. Both flashing flows and non-flashing flows of liquid and incondensable gases have been considered. The present paper shows that for flashing flows good predictions are obtained by using the two-phase valve discharge coefficient defined by Lenzing and multiplying it by the critical flow rate in an ideal nozzle evaluated by either Omega Method or the Homogeneous Non-equilibrium Direct Integration. In case of non-flashing flows of water and air, Leung/Darby formulation of the two-phase valve discharge coefficient together with the Omega Method is more suitable to the prediction of flow rate.

  5. Preliminary observations of gate valve flow interruption tests, Phase 2

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.

    1990-01-01

    This paper presents preliminary observations from the US Nuclear Regulatory Commission/Idaho National Engineering Laboratory Flexible Wedge Gate Valve Qualification and Flow Interruption Test Program, Phase 2. The program investigated the ability of selected boiling water reactor (BWR) process line valves to perform their containment isolation function at high energy pipe break conditions and other more normal flow conditions. The fluid and valve operating responses were measured to provide information concerning valve and operator performance at various valve loadings so that the information could be used to assess typical nuclear industry motor operator sizing equations. Six valves were tested, three 6-in. isolation valves representative of those used in reactor water cleanup systems in BWRs and three 10-in. isolation valves representative of those used in BWR high pressure coolant injection (HPCI) steam lines. The concern with these normally open isolation valves is whether they will close in the event of a downstream pipe break outside of containment. The results of this testing will provide part of the technical insights for NRC efforts regarding Generic Issue 87 (GI-87), Failure of the HPCI Steam Line Without Isolation, which includes concerns about the uncertainties in gate valve motor operator sizing and torque switch settings for these BWR containment isolation valves. As of this writing, the Phase 2 test program has just been completed. Preliminary observations made in the field confirmed most of the results from the Phase 1 test program. All six valves closing in high energy water, high energy steam, and high pressure cold water require more force to close than would be calculated using the typical variables in the standard industry motor operator sizing equations

  6. The modification of main steam safety valves in Qinshan phase Ⅱ expansion project

    International Nuclear Information System (INIS)

    Chen Haiqiao

    2012-01-01

    The main steam safety valves of NPP steam system are second- class nuclear safety component. It used to limit the pressure of SG secondary side and main steam system via emitting steam into the environment. At present, the main steam safety valves have mechanical valves and assisted power valves. According to the experience of power plants at home and abroad, including Qinshan Phase Ⅱ unit 1/2 experience feedback, Qinshan Phase Ⅱ expansion project made modification on valve type, setting value and valve body. This paper introduce the characteristics of different safety valve types, the modification of main steam safety valves and the modification analysis on safety issues.security and impact on the other systems in Qinshan Phase Ⅱ expansion project. (author)

  7. Phase separator safety valve blow-off.

    CERN Multimedia

    G. Perinic

    2006-01-01

    The fast discharge of the CMS solenoid leads to a pressure rise in the phase separator. On August 28th, a fast discharge was triggered at a current level of 19.1 kA. The pressure in the phase separator increased up to the set pressure of the safety valve and some helium was discharged. In consequence of this and prevoious similar observations the liquid helium level in the phase separator has been reduced from 60% to 50% and later to 45% in order to reduce the helium inventory in the magnet.

  8. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  9. Heart valve surgery: EuroSCORE vs. EuroSCORE II vs. Society of Thoracic Surgeons score

    Directory of Open Access Journals (Sweden)

    Muhammad Sharoz Rabbani

    2014-12-01

    Full Text Available Background This is a validation study comparing the European System for Cardiac Operative Risk Evaluation (EuroSCORE II with the previous additive (AES and logistic EuroSCORE (LES and the Society of Thoracic Surgeons’ (STS risk prediction algorithm, for patients undergoing valve replacement with or without bypass in Pakistan. Patients and Methods Clinical data of 576 patients undergoing valve replacement surgery between 2006 and 2013 were retrospectively collected and individual expected risks of death were calculated by all four risk prediction algorithms. Performance of these risk algorithms was evaluated in terms of discrimination and calibration. Results There were 28 deaths (4.8% among 576 patients, which was lower than the predicted mortality of 5.16%, 6.96% and 4.94% by AES, LES and EuroSCORE II but was higher than 2.13% predicted by STS scoring system. For single and double valve replacement procedures, EuroSCORE II was the best predictor of mortality with highest Hosmer and Lemmeshow test (H-L p value (0.346 to 0.689 and area under the receiver operating characteristic (ROC curve (0.637 to 0.898. For valve plus concomitant coronary artery bypass grafting (CABG patients actual mortality was 1.88%. STS calculator came out to be the best predictor of mortality for this subgroup with H-L p value (0.480 to 0.884 and ROC (0.657 to 0.775. Conclusions For Pakistani population EuroSCORE II is an accurate predictor for individual operative risk in patients undergoing isolated valve surgery, whereas STS performs better in the valve plus CABG group.

  10. Optimal Implantation Depth and Adherence to Guidelines on Permanent Pacing to Improve the Results of Transcatheter Aortic Valve Replacement With the Medtronic CoreValve System: The CoreValve Prospective, International, Post-Market ADVANCE-II Study.

    Science.gov (United States)

    Petronio, Anna S; Sinning, Jan-Malte; Van Mieghem, Nicolas; Zucchelli, Giulio; Nickenig, Georg; Bekeredjian, Raffi; Bosmans, Johan; Bedogni, Francesco; Branny, Marian; Stangl, Karl; Kovac, Jan; Schiltgen, Molly; Kraus, Stacia; de Jaegere, Peter

    2015-05-01

    The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis, Minnesota) using optimized implantation techniques and application of international guidelines on cardiac pacing. Conduction disturbances are a frequent complication of transcatheter aortic valve replacement. The rates of PPI in the published reports vary according to bioprosthesis type and the indications for PPI. The primary endpoint was the 30-day incidence of PPI with Class I/II indications when the Medtronic CoreValve System was implanted at an optimal depth (≤6 mm below the aortic annulus). The timing and resolution of all new-onset conduction disturbances were analyzed. A total of 194 patients were treated. The overall rate of PPI for Class I/II indications was 18.2%. An optimal depth was reached in 43.2% of patients, with a nonsignificantly lower incidence of PPI in patients with depths ≤6 mm, compared with those with deeper implants (13.3% vs. 21.1%; p = 0.14). In a paired analysis, new-onset left bundle branch block and first-degree atrioventricular block occurred in 45.4% and 39.0% of patients, respectively, and resolved spontaneously within 30 days in 43.2% and 73.9%, respectively. In patients with new PPI, the rate of intrinsic sinus rhythm increased from 25.9% at 7 days to 59.3% at 30 days (p = 0.004). Optimal Medtronic CoreValve System deployment and adherence to international guidelines on cardiac pacing are associated with a lower rate of new PPI after transcatheter aortic valve replacement, compared with results reported in previous studies. (CoreValve Advance-II Study: Prospective International Post-Market Study [ADVANCE II]; NCT01624870). Copyright © 2015 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  11. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  12. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    Science.gov (United States)

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  13. Phase-mapping technique for the evaluation of aortic valve stenosis by MR

    International Nuclear Information System (INIS)

    Engels, G.; Mueller, E.; Reynen, K.; Wilke, N.; Bachmann, K.

    1992-01-01

    New MR-techniques for quantitative blood flow registration such as phase-mapping (a two-dimensional space-resolved technique with a time-averaged measurement of blood flow) or RACE (real-time acquisition and evaluation of blood flow in one-dimensional space projection) are available for the diagnosis of valvular heart disease. Initial results of grading aortic valve stenosis by these methods are shown in comparison to continuous wave Ultrasound-Doppler. Two groups of 15 patients were examined by RACE or phase-mapping, 12 respectively 8 of whom suffered from an aortic valve stenosis. The shape of blood flow profiles as well as grading of aortic valve stenosis show high concordance when comparing the results of MR and Doppler technique. Good reliability and practicability of the demonstrated MR-method are shown. With respect to the results of RACE and phase-mapping the development of an alternative and competing MR-method for the evaluation of valvular heart disease and shunt diagnostics seems possible. (orig.)

  14. Phase-mapping technique for the evaluation of aortic valve stenosis by MR

    Energy Technology Data Exchange (ETDEWEB)

    Engels, G. [Medizinische Klinik 2, Univ. of Erlangen (Germany); Mueller, E. [Siemens Medical Engineering Group, Erlangen (Germany); Reynen, K. [Medizinische Klinik 2, Univ. of Erlangen (Germany); Wilke, N. [Siemens Medical Engineering Group, Erlangen (Germany); Bachmann, K. [Medizinische Klinik 2, Univ. of Erlangen (Germany)

    1992-08-01

    New MR-techniques for quantitative blood flow registration such as phase-mapping (a two-dimensional space-resolved technique with a time-averaged measurement of blood flow) or RACE (real-time acquisition and evaluation of blood flow in one-dimensional space projection) are available for the diagnosis of valvular heart disease. Initial results of grading aortic valve stenosis by these methods are shown in comparison to continuous wave Ultrasound-Doppler. Two groups of 15 patients were examined by RACE or phase-mapping, 12 respectively 8 of whom suffered from an aortic valve stenosis. The shape of blood flow profiles as well as grading of aortic valve stenosis show high concordance when comparing the results of MR and Doppler technique. Good reliability and practicability of the demonstrated MR-method are shown. With respect to the results of RACE and phase-mapping the development of an alternative and competing MR-method for the evaluation of valvular heart disease and shunt diagnostics seems possible. (orig.)

  15. A self-regulating valve for single-phase liquid cooling of microelectronics

    International Nuclear Information System (INIS)

    Donose, Radu; De Volder, Michaël; Peirs, Jan; Reynaerts, Dominiek

    2011-01-01

    This paper reports on the design, optimization and testing of a self-regulating valve for single-phase liquid cooling of microelectronics. Its purpose is to maintain the integrated circuit (IC) at constant temperature and to reduce power consumption by diminishing flow generated by the pump as a function of the cooling requirements. It uses a thermopneumatic actuation principle that combines the advantages of zero power consumption and small size in combination with a high flow rate and low manufacturing costs. The valve actuation is provided by the thermal expansion of a liquid (actuation fluid) which, at the same time, actuates the valve and provides feed-back sensing. A maximum flow rate of 38 kg h −1 passes through the valve for a heat load up to 500 W. The valve is able to reduce the pumping power by up to 60% and it has the capability to maintain the IC at a more uniform temperature.

  16. Small Business Innovation Research GRC Phase I, Phase II, and Post-Phase II Opportunity Assessment for 2015

    Science.gov (United States)

    Nguyen, Hung D.; Steele, Gynelle C.

    2016-01-01

    This report outlines the 2015 Small Business Innovation Research/Small Business Technology Transfer (SBIR/STTR) Phase I, Phase II, and Post-Phase II opportunity contract award results associated with NASA's Aeronautics Research Mission Directorate (ARMD), Human Exploration and Operations Mission Directorate (HEOMD), Science Mission Directorate (SMD), and Space Technology Mission Directorate (STMD) for NASA Glenn Research Center. The report also highlights the number of Phase I, Phase II, and Post-Phase II contracts awarded by mission directorate. The 2015 Phase I contract awards to companies in Ohio and their corresponding technologies are also discussed.

  17. Optimal implantation depth and adherence to guidelines on permanent pacing to improve the results of transcatheter aortic valve replacement with the medtronic corevalve system: The CoreValve prospective, international, post-market ADVANCE-II study

    NARCIS (Netherlands)

    A.S. Petronio (Anna); J.-M. Sinning (Jan-Malte); N.M. van Mieghem (Nicolas); G. Zucchelli (Giulio); G. Nickenig (Georg); R. Bekeredjian (Raffi); J. Bosmans (Johan); F. Bedogni (Francesco); M. Branny (Marian); K. Stangl (Karl); J. Kovac (Jan); M. Schiltgen (Molly); S. Kraus (Stacia); P.P.T. de Jaegere (Peter)

    2015-01-01

    textabstractObjectives The aim of the CoreValve prospective, international, post-market ADVANCE-II study was to define the rates of conduction disturbances and permanent pacemaker implantation (PPI) after transcatheter aortic valve replacement with the Medtronic CoreValve System (Minneapolis,

  18. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Motor-operated Valve Program at NPP Krsko (NEK) - Status and Overview

    International Nuclear Information System (INIS)

    Nikolic, M; Jagodar, N.; Cerjak, J.; Butkovic, V.

    2002-01-01

    On the basics of US NRC Generic Letter 89-10 Safety-related Motor-operated Valve Testing and Surveillance and subsequent generic letters, Motor-operated Valve (MOV) Program at NEK has been developing. Namely, the holders of nuclear power plant operating licenses has to verify the design basis capability of safety-related e.g. important-to-safety MOVs, as well as to ensure the same for the life of the plant. In light of that, each plant should establish a program to address stressed issues for each program MOV (124 at NEK). Such comprehensive task requires significant effort in many aspects, and basically multidisciplinary skills. NEK MOV Program represents a blend of engineering and in-plant testing, comprised of three phases: Phase I Engineering, Phase II Field Implementation and Phase III Trending. Currently, the program is about the end of Phase I and II, as well as in development of engineering basis for launching Phase III. Overview of the major programmatic issues will be given in this paper along with ongoing activities: testing process, gear-ratio modification, pressure locking/thermal binding susceptibility screening and preventive maintenance. (author)

  20. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  1. Experimental and Computational Study of Two-phase (Air–Palm Oil Flow through Pipe and Control Valve in Series

    Directory of Open Access Journals (Sweden)

    Arivazhagan M.

    2009-03-01

    Full Text Available The contact of two or more immiscible liquids is encountered widely in the chemical and petroleum industries. Studies on operating characteristics of control valves with two phase flow have not been given much attention in the literature despite its industrial importance during design and selection as well as plant operations .The present work attempts to study experimentally the effect of two phase flow on pressure drop across pipe and control valve in series and compare with simulated results. Two-phase computational fluid dynamics (CFD calculations, using commercial CFD package FLUENT 6.2.16, were employed to calculate the simulated the pressure drop in Air–Palm oil flow in pipes and control valves. The Air flow rate varied from 25 to100 l/h flow rate. For constant valve position and Air flow rate, the Palm oil flow rate was varied from 50 to 150 l/h. The numerical results were validated against experimental data. The prediction of the pressure drop characteristics in pipe and valve were within an average error of about ± 3 %. A comparison of experimental and computed profiles was found to be in good agreement.

  2. Analysis of flow induced valve operation and pressure wave propagation for single and two-phase flow conditions

    International Nuclear Information System (INIS)

    Nagel, H.

    1986-01-01

    The flow induced valve operation is calculated for single and two-phase flow conditions by the fluid dynamic computer code DYVRO and results are compared to experimental data. The analysis show that the operational behaviour of the valves is not only dependent on the condition of the induced flow, but also the pipe flow can cause a feedback as a result of the induced pressure waves. For the calculation of pressure wave propagation in pipes of which the operation of flow induced valves has a considerable influence it is therefore necessary to have a coupled analysis of the pressure wave propagation and the operational behaviour of the valves. The analyses of the fast transient transfer from steam to two-phase flow show a good agreement with experimental data. Hence even these very high loads on pipes resulting from such fluid dynamic transients can be calculated realistically. (orig.)

  3. Resistance calculation of un-fully developed two-phase flow through high differential pressure regulating valves

    International Nuclear Information System (INIS)

    Xu Mingyang; Wang Wenran; Wang Jiaying

    1999-01-01

    To reduce the flow velocity in the high differential pressure regulating valve with labyrinth. A type of complicated valve core structure were designed with tortuous flow path made from reversal double elbows. It is very difficult to calculate the pressure-drop of the un-fully developed two-phase flow under high temperature and pressure which flow through the valve core. A calculation method called 'constant (varing) pressure-drop progressing step by step design method' was developed. The complicated flow path was disintegrated into a series of independent resistance units and with the valve stem end progressing step by step the dimensions of the flow path were designed in accordance with the principle that in every position the total pressure-drop of the valve should amount to that required by the design goal curve. In the course of calculating the total pressure-drop, the valve flow path was also divided into a series of independent resistance units. The experiment results show that design flow characteristics are approximately consistent with the flow characteristics measured in the test

  4. Role of recent research in improving check valve reliability at nuclear power plants

    International Nuclear Information System (INIS)

    Kalsi, M.S.; Horst, C.L.; Wang, J.K.; Sharma, V.

    1990-01-01

    Check valve failures at nuclear power plants in recent years have led to serious safety concerns, and caused extensive damage to other plant components which had a significant impact on plant availability. In order to understand the failure mechanism and improve the reliability of check valves, a systematic research effort was proposed by Kalsi Engineering, Inc. to U.S. Nuclear Regulatory Commission (NRC). The overall goal of the research was to develop models for predicting the performance and degradation of swing check valves in nuclear power plant systems so that appropriate preventive maintenance or design modifications can be performed to improve the reliability of check valves. Under Phase I of this research, a large matrix of tests was run with instrumented swing check valves to determine the stability of the disc under a variety of upstream flow disturbances, covering a wide range of disc stop positions and flow velocities in two different valve sizes. The goals of Phase II research were to develop predictive models which quantify the anticipated degradation of swing check valves that have flow disturbances closely upstream of the valve and are operating under flow velocities that do not result in full disc opening. This research allows the inspection/maintenance activities to be focussed on those check valves that are more likely to suffer premature degradation. The quantitative wear and fatigue prediction methodology can be used to develop a sound preventive maintenance program. The results of the research also show the improvements in check valve performance/reliability that can be achieved by certain modifications in the valve design

  5. Design of Phase II Non-inferiority Trials.

    Science.gov (United States)

    Jung, Sin-Ho

    2017-09-01

    With the development of inexpensive treatment regimens and less invasive surgical procedures, we are confronted with non-inferiority study objectives. A non-inferiority phase III trial requires a roughly four times larger sample size than that of a similar standard superiority trial. Because of the large required sample size, we often face feasibility issues to open a non-inferiority trial. Furthermore, due to lack of phase II non-inferiority trial design methods, we do not have an opportunity to investigate the efficacy of the experimental therapy through a phase II trial. As a result, we often fail to open a non-inferiority phase III trial and a large number of non-inferiority clinical questions still remain unanswered. In this paper, we want to develop some designs for non-inferiority randomized phase II trials with feasible sample sizes. At first, we review a design method for non-inferiority phase III trials. Subsequently, we propose three different designs for non-inferiority phase II trials that can be used under different settings. Each method is demonstrated with examples. Each of the proposed design methods is shown to require a reasonable sample size for non-inferiority phase II trials. The three different non-inferiority phase II trial designs are used under different settings, but require similar sample sizes that are typical for phase II trials.

  6. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  7. Centrifuge workers study. Phase II, completion report

    International Nuclear Information System (INIS)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom

  8. Centrifuge workers study. Phase II, completion report

    Energy Technology Data Exchange (ETDEWEB)

    Wooten, H.D.

    1994-09-01

    Phase II of the Centrifuge Workers Study was a follow-up to the Phase I efforts. The Phase I results had indicated a higher risk than expected among centrifuge workers for developing bladder cancer when compared with the risk in the general population for developing this same type of cancer. However, no specific agent could be identified as the causative agent for these bladder cancers. As the Phase II Report states, Phase I had been limited to workers who had the greatest potential for exposure to substances used in the centrifuge process. Phase II was designed to expand the survey to evaluate the health of all employees who had ever worked in Centrifuge Program Departments 1330-1339 but who had not been interviewed in Phase I. Employees in analytical laboratories and maintenance departments who provided support services for the Centrifuge Program were also included in Phase II. In December 1989, the Oak Ridge Associated Universities (ORAU), now known as Oak Ridge Institute for Science and Education (ORISE), was contracted to conduct a follow-up study (Phase II). Phase H of the Centrifuge Workers Study expanded the survey to include all former centrifuge workers who were not included in Phase I. ORISE was chosen because they had performed the Phase I tasks and summarized the corresponding survey data therefrom.

  9. Sample Exchange Evaluation (SEE) Report - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Winters, W.I.

    1994-09-28

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site`s high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified.

  10. Sample Exchange Evaluation (SEE) Report - Phase II

    International Nuclear Information System (INIS)

    Winters, W.I.

    1994-01-01

    This report describes the results from Phase II of the Sample Exchange Evaluation (SEE) Program, a joint effort to compare analytical laboratory performance on samples from the Hanford Site's high-level waste tanks. In Phase II, the program has been expanded to include inorganic constituents in addition to radionuclides. Results from Phase II that exceeded 20% relative percent difference criteria are identified

  11. Effect of tricuspid regurgitation and the right heart on survival after transcatheter aortic valve replacement: insights from the Placement of Aortic Transcatheter Valves II inoperable cohort.

    Science.gov (United States)

    Lindman, Brian R; Maniar, Hersh S; Jaber, Wael A; Lerakis, Stamatios; Mack, Michael J; Suri, Rakesh M; Thourani, Vinod H; Babaliaros, Vasilis; Kereiakes, Dean J; Whisenant, Brian; Miller, D Craig; Tuzcu, E Murat; Svensson, Lars G; Xu, Ke; Doshi, Darshan; Leon, Martin B; Zajarias, Alan

    2015-04-01

    Tricuspid regurgitation (TR) and right ventricular (RV) dysfunction adversely affect outcomes in patients with heart failure or mitral valve disease, but their impact on outcomes in patients with aortic stenosis treated with transcatheter aortic valve replacement has not been well characterized. Among 542 patients with symptomatic aortic stenosis treated in the Placement of Aortic Transcatheter Valves (PARTNER) II trial (inoperable cohort) with a Sapien or Sapien XT valve via a transfemoral approach, baseline TR severity, right atrial and RV size and RV function were evaluated by echocardiography according to established guidelines. One-year mortality was 16.9%, 17.2%, 32.6%, and 61.1% for patients with no/trace (n=167), mild (n=205), moderate (n=117), and severe (n=18) TR, respectively (Pright atrial and RV enlargement were also associated with increased mortality (Pright atrial and RV enlargement, but not RV dysfunction. There was an interaction between TR and mitral regurgitation severity (P=0.04); the increased hazard of death associated with moderate/severe TR only occurred in those with no/trace/mild mitral regurgitation. In inoperable patients treated with transcatheter aortic valve replacement, moderate or severe TR and right heart enlargement are independently associated with increased 1-year mortality; however, the association between moderate or severe TR and an increased hazard of death was only found in those with minimal mitral regurgitation at baseline. These findings may improve our assessment of anticipated benefit from transcatheter aortic valve replacement and support the need for future studies on TR and the right heart, including whether concomitant treatment of TR in operable but high-risk patients with aortic stenosis is warranted. URL: http://www.clinicaltrials.gov. Unique identifier: NCT01314313. © 2015 American Heart Association, Inc.

  12. Military Family Coping Project - Phase II

    Science.gov (United States)

    2015-05-01

    Anxiety, Life Satisfaction , Addiction, Trauma 4 The Military Family Coping Project reflects two phases. The first consisted of a series of focus...need for and guided the work of the Military Family Coping Project Phase II funded by TATRC. The Military Family Coping Project Phase II was...solidarity. For the purposes of family functioning analyses, married and unmarried soldiers were analyzed separately because marital status affects

  13. Phase II clinical development of new drugs

    CERN Document Server

    Ting, Naitee; Ho, Shuyen; Cappelleri, Joseph C

    2017-01-01

    This book focuses on how to appropriately plan and develop a Phase II program, and how to design Phase II clinical trials and analyze their data. It provides a comprehensive overview of the entire drug development process and highlights key questions that need to be addressed for the successful execution of Phase II, so as to increase its success in Phase III and for drug approval. Lastly it warns project team members of the common potential pitfalls and offers tips on how to avoid them.

  14. Aerospace Systems Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Proposal Title: Aerospace Systems Monitor PHASE 1 Technical Abstract: This Phase II STTR project will continue development and commercialization of the Aerospace...

  15. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  16. Continuous PECS II block for postoperative analgesia in patients undergoing transapical transcatheter aortic valve implantation.

    Science.gov (United States)

    Shakuo, Tomoharu; Kakumoto, Shinichi; Kuribayashi, Junya; Oe, Katsunori; Seo, Katsuhiro

    2017-01-01

    It has been reported that PECS II block can alleviate postoperative pain following transapical transcatheter aortic valve implantation (TA-TAVI). However, the effectiveness of continuous PECS II block with catheterization has not yet been reported on the postoperative pain in patients undergoing TA-TAVI. We experienced two cases of TA-TAVI who received PECS II block with catheterization to manage postoperative pain. In the first case, a bolus injection for intraoperative pain and subsequent catheterization were performed before the implantation. However, the patient developed severe pain postoperatively in spite of the continuous block due to displacement of the catheter. In the second case, a bolus injection and the catheterization for the continuous block were performed before and after the implantation, respectively, which provided high-quality pain control. Continuous PECS II block may be useful to control perioperative pain associated with TA-TAVI. The insertion of the catheter after the implantation could be useful to avoid its displacement during the surgery.

  17. Outcome of double vs. single valve replacement for rheumatic heart disease

    International Nuclear Information System (INIS)

    Akhtar, R.P.; Abid, A.R.

    2010-01-01

    To compare the follow-up results of double valve replacement (DVR) i.e. mitral valve replacement (MVR) and aortic valve replacement (AVR) vs. isolated MVR or AVR for rheumatic heart disease. Study Design: An interventional qausi-experimental study. Prospective follow-up of 493 patients with mechanical heart valves was carried out using clinical assessment, international normalized ratio and echocardiography. Patients were divided into three groups: group I having MVR, group II having AVR and group III having DVR. Survival, time and causes of mortality, and frequency of valve thrombosis, haemorrhage and cerebrovascular haemorrhage was noted in the three groups and described as proportions. Actuarial survival was analyzed by Kaplan-Meier method. There were 493 with 287 (58.3%) in group I, 87 (17.6%) in group II and 119 (24.1%) in group III. Total follow-up was 2429.2 patient (pt)-years. Of 77 (15.6%) deaths, 19 (3.8%) were in-hospital and 58 (11.8%) were late. In-hospital mortality was highest 4 (4.6%) in group II followed by 5 (4.2%) group III and 10 (3.5%) group I. Late deaths were 39 (13.4%) in group I, 9 (10.2%) in group II and 10 (8.3%) in group III. The total actuarial survival was 84.4% with survival of 83%, 85.1%, 87.4% in groups I, II and III respectively. On follow-up valve thrombosis occurred in 12 (0.49%/pt-years) patients; 9 (0.67%/pt-years) group I, 1 (0.22%/pt-years) in group II and 2 (0.31%/pt-years) in group III. Severe haemorrhage occurred in 19 (0.78%/pt-years); 14 in (1.04%/pt-years) in group I, 3 (0.66%/pt-years) group II and 2 (0.31%/pt-years) in group III. Cerebrovascular accidents occurred in 34 (1.3%/pt-years); 26 (1.95%/pt-years) in group I and 4 in groups II (0.89%/pt-years) and III (0.62%/pt-years) each. In patients with rheumatic heart disease having combined mitral and aortic valve disease DVR should be performed whenever indicated as it has similar in-hospital mortality and better late survival as compared to isolated aortic or mitral

  18. Status of Gerda Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of {sup 76}Ge. In Phase I of the experiment a background index (BI) of 10{sup -2} cts/(keV.kg.yr) was reached. No signal has been found and a lower limit on the half-life of 2.1.10{sup 25} yr (at 90% C.L.) is extracted. The aim of Phase II is to double the Ge mass and further reduce the BI by an order of magnitude to explore half-lives of about 10{sup 26} yr. Thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by an active veto to read out argon scintillation light. The Phase II commissioning showed that two of the major background components, external γ-rays from {sup 214}Bi and {sup 208}Tl decays, can be suppressed up to two orders of magnitude. This talk presents the current status of the GERDA Phase II upgrade.

  19. Safety/relief valve quencher loads: evaluation for BWR Mark II and III containments

    International Nuclear Information System (INIS)

    Su, T.M.

    1982-10-01

    Boiling water reactor (BWR) plants are equipped with safety/relief valves (SRVs) to protect the reactor from overpressurization. Plant operational transients, such as turbine trips, will actuate the SRV. Once the SRV opens, the air column within the partially submerged discharge line is compressed by the high-pressure steam released from the reactor. The compressed air discharged into the suppression pool produces high-pressure bubbles. Oscillatory expansion and contraction of these bubbles create hydrodynamic loads on the containment structures, piping, and equipment inside containment. This report presents the results of the staff's evaluation of SRV loads. The evaluation, however, is limited to the quencher devices used in Mark II and III containments. With respect to Mark I containments, the SRV acceptance criteria are presented in NUREG-0661 issued July 1980. The staff acceptance criteria for SRV loads for Mark II and III containments are presented in this report

  20. Test of GERDA Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Gusev, Konstantin [Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard; Wagner, Victoria [Max-Planck Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2014-07-01

    The GERDA experiment searches for the lepton number violating neutrinoless double beta decay (0νββ) of {sup 76}Ge. The experiment uses HPGe detectors enriched in {sup 76}Ge as source and detection material. In GERDA Phase I five BEGe detectors were operated successfully. These detectors are distinguished for improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. In Phase II additional 25 BEGe detectors will be installed. New electronics and radio-pure low-mass holders were specially designed for Phase II. Prior to the installation in GERDA all BEGe detectors are tested in their final assembly in the LNGS underground laboratory. This talk presents the mechanics and performance of the GERDA Phase II detector assembly.

  1. Associations between valve repair and reduced operative mortality in 21,056 mitral/tricuspid double valve procedures.

    Science.gov (United States)

    Rankin, J Scott; Thourani, Vinod H; Suri, Rakesh M; He, Xia; O'Brien, Sean M; Vassileva, Christina M; Shah, Ashish S; Williams, Matthew

    2013-09-01

    Repair of either the mitral (M) or tricuspid (T) valve in single valve surgery is associated with reduced operative mortality. It is unclear, however, how valve repair influences mortality in combined MT procedures. This topic was evaluated in the Society of Thoracic Surgeons database. From 1993 through 2007, 21 056 patients underwent concomitant MT valve surgery. Group I had M&T replacement (n = 1130), Group II had M repair and T replacement (n = 216), Group III had M replacement and T repair (n = 11 448) and Group IV had both M&T repair (n = 8262). Unadjusted operative mortalities (UOMs) and morbidities of Groups I-IV were assessed, and logistic regression analysis adjusted for differences in baseline patient profiles. Surgical outcomes were expressed as UOMs, and also adjusted odds ratios (ORs) for mortality. Group IV was older with more coronary artery bypass grafting and generally less comorbidity, and Group I had more endocarditis, mitral stenosis and reoperation. UOM values were: Group I = 16.8, Group II = 10.2, Group III = 10.3 and Group IV = 8.0%. In the multivariable model, factors influencing mortality included: age (per 5-year increase, OR = 1.15), renal failure with dialysis (OR = 3.22), emergency status (OR = 3.14), second or more reoperations (OR = 1.92) and later surgical date (OR = 0.63). Both M and T repair were independently associated with lower operative mortalities vs prosthetic valve replacement (OR = 0.83 and 0.60, respectively, P replacement and, when feasible, multiple valve repair should be considered the optimal treatment. Within the limitations of observational analysis, these data support continued efforts to increase M&T repair rates.

  2. On-line liquid phase micro-extraction based on drop-in-plug sequential injection lab-at-valve platform for metal determination

    Energy Technology Data Exchange (ETDEWEB)

    Mitani, Constantina [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece); Anthemidis, Aristidis N., E-mail: anthemid@chem.auth.gr [Laboratory of Analytical Chemistry, Department of Chemistry, Aristotle University, Thessaloniki 54124 (Greece)

    2013-04-10

    Highlights: ► Drop-in-plug micro-extraction based on SI-LAV platform for metal preconcentration. ► Automatic liquid phase micro-extraction coupled with FAAS. ► Organic solvents with density higher than water are used. ► Lead determination in environmental water and urine samples. -- Abstract: A novel automatic on-line liquid phase micro-extraction method based on drop-in-plug sequential injection lab-at-valve (LAV) platform was proposed for metal preconcentration and determination. A flow-through micro-extraction chamber mounted at the selection valve was adopted without the need of sophisticated lab-on-valve components. Coupled to flame atomic absorption spectrometry (FAAS), the potential of this lab-at-valve scheme is demonstrated for trace lead determination in environmental and biological water samples. A hydrophobic complex of lead with ammonium pyrrolidine dithiocarbamate (APDC) was formed on-line and subsequently extracted into an 80 μL plug of chloroform. The extraction procedure was performed by forming micro-droplets of aqueous phase into the plug of the extractant. All critical parameters that affect the efficiency of the system were studied and optimized. The proposed method offered good performance characteristics and high preconcentration ratios. For 10 mL sample consumption an enhancement factor of 125 was obtained. The detection limit was 1.8 μg L{sup −1} and the precision expressed as relative standard deviation (RSD) at 50.0 μg L{sup −1} of lead was 2.9%. The proposed method was evaluated by analyzing certified reference materials and applied for lead determination in natural waters and urine samples.

  3. Effects of various intake valve timings and spark timings on combustion, cyclic THC and NOX emissions during cold start phase with idle operation in CVVT engine

    International Nuclear Information System (INIS)

    Choi, Kwan Hee; Lee, Hyung Min; Hwang, In Goo; Myung, Cha Lee; Park, Sim Soo

    2008-01-01

    In a gasoline SI engine, valve events and spark timings put forth a major influence on overall efficiency, fuel economy, and exhaust emissions. Residual gases controlled by the valve overlap can be used to reduce NOx emissions and the spark retardation technique can be used to improve raw THC emissions and catalyst light-off performance during the cold start phase. This paper investigated the behaviors of the engine and its combustion characteristics with various intake valve timings and spark timings during the fast idle condition and cold start. And cyclic THC and NOx emissions were measured at the exhaust port and their formation mechanisms were examined with fast response gas analyzers. As a result, THCs and NOx were reduced by 35% and 23% with optimizing valve overlap and spark advance during the cold transient start phase. Consequently, the valve events and ignition timings were found to significantly affect combustion phenomena and cold-start emissions

  4. 129I Interlaboratory comparison: phase I and phase II

    International Nuclear Information System (INIS)

    Caffee, M. W.; Roberts, M. L.

    1999-01-01

    An interlaboratory comparison exercise for 129 I was organized and conducted. Nine laboratories participated in the exercise to either a full or limited extent. In Phase I of the comparison, 11 samples were measured. The suite of samples contained both synthetic ''standard type'' materials (i.e., AgI) and environmental materials. The isotopic 129 I/ 127 I ratios of the samples varied from 10 -8 to 10 -14 . In this phase, each laboratory was responsible for its own chemical preparation of the samples. In Phase I, the 129 I AMS measurements for prepared AgI were in good agreement. However, large discrepancies were seen in 129 I AMS measurements of environmental samples. Because of the large discrepancies seen in the Phase I 129 I intercomparison, a subsequent study was conducted. In Phase II of the 129 I intercomparison, three separate laboratories prepared AgI from two environmental samples (IAEA 375 soil and maples leaves). Each laboratory used its own chemical preparation method with each of the methods being distinctly different. The resulting six samples (two sets of three) were then re-distributed to the participating 129 I AMS facilities and 129 I/ 127 I ratios measured. Results and discussion of both the Phase I and Phase II interlaboratory comparison are presented

  5. Research design and improvement of high temperature high pressure solenoid valve

    International Nuclear Information System (INIS)

    Luo Yongtang

    1987-12-01

    A process for development of the pilot type high temperature high pressure solenoid valve used in a PWR power plant is described. The whole development process might be divided into two phases: research design and improvement. In the former phase the questions had chiefly been approached in the following several aspects: the principle construction design, the determination of values for the constructionally key elements, the valve seal design and the solenoid actuator design, and made such valve's successful design in the main. In the latter phase an improvement had been made upon such valve against the problems during the testing use of the valve for a period of time, i.e. the unsatisfactory leak tightness, and achieved satisfactory results. The consummate success in this development not only has met the needs of the engineering project, but also made us obtain a valuable experience useful to design the similar valves

  6. Upgrade for Phase II of the Gerda experiment

    Science.gov (United States)

    Agostini, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hiller, R.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Ioannucci, L.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kermaïdic, Y.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Nisi, S.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Ransom, C.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schütz, A.-K.; Schulz, O.; Schwingenheuer, B.; Selivanenko, O.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zsigmond, A. J.; Zuber, K.; Zuzel, G.

    2018-05-01

    The Gerda collaboration is performing a sensitive search for neutrinoless double beta decay of ^{76}Ge at the INFN Laboratori Nazionali del Gran Sasso, Italy. The upgrade of the Gerda experiment from Phase I to Phase II has been concluded in December 2015. The first Phase II data release shows that the goal to suppress the background by one order of magnitude compared to Phase I has been achieved. Gerda is thus the first experiment that will remain "background-free" up to its design exposure (100 kg year). It will reach thereby a half-life sensitivity of more than 10^{26} year within 3 years of data collection. This paper describes in detail the modifications and improvements of the experimental setup for Phase II and discusses the performance of individual detector components.

  7. 40 CFR 72.73 - State issuance of Phase II permits.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false State issuance of Phase II permits. 72.73 Section 72.73 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) PERMITS REGULATION Acid Rain Phase II Implementation § 72.73 State issuance of Phase II permits...

  8. 19 mm sized bileaflet valve prostheses' flow field investigated by bidimensional laser Doppler anemometry (part II: maximum turbulent shear stresses)

    Science.gov (United States)

    Barbaro, V; Grigioni, M; Daniele, C; D'Avenio, G; Boccanera, G

    1997-11-01

    The investigation of the flow field generated by cardiac valve prostheses is a necessary task to gain knowledge on the possible relationship between turbulence-derived stresses and the hemolytic and thrombogenic complications in patients after valve replacement. The study of turbulence flows downstream of cardiac prostheses, in literature, especially concerns large-sized prostheses with a variable flow regime from very low up to 6 L/min. The Food and Drug Administration draft guidance requires the study of the minimum prosthetic size at a high cardiac output to reach the maximum Reynolds number conditions. Within the framework of a national research project regarding the characterization of cardiovascular endoprostheses, an in-depth study of turbulence generated downstream of bileaflet cardiac valves is currently under way at the Laboratory of Biomedical Engineering of the Istituto Superiore di Sanita. Four models of 19 mm bileaflet valve prostheses were used: St Jude Medical HP, Edwards Tekna, Sorin Bicarbon, and CarboMedics. The prostheses were selected for the nominal Tissue Annulus Diameter as reported by manufacturers without any assessment of valve sizing method, and were mounted in aortic position. The aortic geometry was scaled for 19 mm prostheses using angiographic data. The turbulence-derived shear stresses were investigated very close to the valve (0.35 D0), using a bidimensional Laser Doppler anemometry system and applying the Principal Stress Analysis. Results concern typical turbulence quantities during a 50 ms window at peak flow in the systolic phase. Conclusions are drawn regarding the turbulence associated to valve design features, as well as the possible damage to blood constituents.

  9. Status of the Gerda phase II experiment

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, Andrea [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    The Gerda experiment searches for the neutrinoless double beta decay (0νββ) in {sup 76}Ge. The first phase of the experiment collected 21.6 kg. yr of exposure with a background index (BI) of 0.01 cts/(keV . kg . yr). No signal was observed and a lower limit for the 0νββ half-life was set to T{sup 0νββ}{sub 1/2} < 2.1 . 10{sup 25} yr (90% C.L). The apparatus has now been upgraded to the Phase II configuration. In Phase II 38 kg of HPGe detectors will be operated to reach an exposure of 100 kg . yr. The goal of Gerda Phase II is to lower the BI to 10{sup -3} cts/(keV . kg . y), in order to reach the sensitivity for T{sup 0νββ}{sub 1/2} = O(10{sup 26}) yr. The additional target mass is constituted of 30 custom made BEGe detectors with higher energy resolution and better pulse shape discrimination performance. The detectors are operated in new radio-pure low-mass holders. The liquid argon surrounding the detectors has been instrumented to veto the background events which produce scintillation light. In this talk the current status and the performance of the Gerda Phase II are presented.

  10. Lunar Health Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — During the Phase II Lunar Health Monitor program, Orbital Research will develop a second generation wearable sensor suite for astronaut physiologic monitoring. The...

  11. 78 FR 76789 - Additional Connect America Fund Phase II Issues

    Science.gov (United States)

    2013-12-19

    ... inspection and copying during normal business hours in the FCC Reference Information Center, Portals II, 445... Phase I to Phase II. 2. Timing of Phase II Support Disbursements. In the USF/ICC Transformation Order... language in paragraph 180 of the USF/ICC Transformation Order. We now seek to more fully develop the record...

  12. Probability of success for phase III after exploratory biomarker analysis in phase II.

    Science.gov (United States)

    Götte, Heiko; Kirchner, Marietta; Sailer, Martin Oliver

    2017-05-01

    The probability of success or average power describes the potential of a future trial by weighting the power with a probability distribution of the treatment effect. The treatment effect estimate from a previous trial can be used to define such a distribution. During the development of targeted therapies, it is common practice to look for predictive biomarkers. The consequence is that the trial population for phase III is often selected on the basis of the most extreme result from phase II biomarker subgroup analyses. In such a case, there is a tendency to overestimate the treatment effect. We investigate whether the overestimation of the treatment effect estimate from phase II is transformed into a positive bias for the probability of success for phase III. We simulate a phase II/III development program for targeted therapies. This simulation allows to investigate selection probabilities and allows to compare the estimated with the true probability of success. We consider the estimated probability of success with and without subgroup selection. Depending on the true treatment effects, there is a negative bias without selection because of the weighting by the phase II distribution. In comparison, selection increases the estimated probability of success. Thus, selection does not lead to a bias in probability of success if underestimation due to the phase II distribution and overestimation due to selection cancel each other out. We recommend to perform similar simulations in practice to get the necessary information about the risk and chances associated with such subgroup selection designs. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Oxygen-Methane Thruster, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Two main innovations will be developed in the Phase II effort that are fundamentally associated with our gaseous oxygen/gaseous methane RCS thruster. The first...

  14. OSAS Surgery and Postoperative Discomfort: Phase I Surgery versus Phase II Surgery

    Directory of Open Access Journals (Sweden)

    Giulio Gasparini

    2015-01-01

    Full Text Available Introduction. This study aims to investigate the reasons that discourage the patients affected by OSAS to undergo orthognathic surgery and compares the postoperative discomfort of phase I (soft tissue surgery and phase II (orthognathic surgery procedures for treatment of OSAS. Material and Methods. A pool of 46 patients affected by OSAS was divided into two groups: “surgery patients” who accepted surgical treatments of their condition and “no surgery patients” who refused surgical procedures. The “surgery patients” group was further subdivided into two arms: patients who accepted phase I procedures (IP and those who accepted phase II (IIP. To better understand the motivations behind the refusal of II phase procedures, we asked the patients belonging to both the IP group and “no surgery” group to indicate the main reason that influenced their decision to avoid II phase procedures. We also monitored and compared five parameters of postoperative discomfort: pain, painkiller assumption, length of hospitalization, foreign body sensation, and diet assumption following IP and IIP procedures. Results. The main reason to avoid IIP procedures was the concern of a more severe postoperative discomfort. Comparison of the postoperative discomfort following IP versus IIP procedures showed that the former scored worse in 4 out of 5 parameters analyzed. Conclusion. IIP procedures produce less postoperative discomfort. IIP procedures, namely, orthognathic surgery, should be the first choice intervention in patients affected by OSAS and dentoskeletal malformation.

  15. Barriers to participation in a phase II cardiac rehabilitation programme.

    Science.gov (United States)

    Mak, Y M W; Chan, W K; Yue, C S S

    2005-12-01

    To identify barriers to participation in a phase II cardiac rehabilitation programme and measures that may enhance participation. Prospective study. Regional hospital, Hong Kong. Cardiac patients recruited for a phase I cardiac rehabilitation programme from July 2002 to January 2003. Reasons for not participating in a phase II cardiac rehabilitation programme. Of the 193 patients recruited for a phase I cardiac rehabilitation programme, 152 (79%) patients, with a mean age of 70.3 years (standard deviation, 11.9 years), did not proceed to phase II programme. Eleven (7%) deaths occurred before commencement of phase II and 74 (49%) patients were considered physically unfit. Reasons for the latter included fractures, pain, or degenerative changes in the lower limbs (24%), and co-morbidities such as cerebrovascular accident (19%), chronic renal failure (11%), congestive heart failure (9%), and unstable angina (8%). Phase II rehabilitation was postponed until after completion of scheduled cardiac interventions in 13% of patients. Failure of physicians to arrange the pre-phase II exercise stress test as per protocol was reported in 7% of patients. Other reasons were reported: work or time conflicts (16%), non-compliance with cardiac treatment (5%), financial constraints (4%), self-exercise (3%), fear after exercise stress testing (3%), and patients returning to their original cardiologists for treatment (3%). A significant (79%) proportion of patients did not proceed to a phase II cardiac rehabilitation programme for a variety of reasons. These included physical unfitness, work or time conflicts, and need to attend scheduled cardiac interventions. Further studies are required to determine how to overcome obstacles to cardiac rehabilitation.

  16. Operating experience and design criteria of sodium valves

    International Nuclear Information System (INIS)

    Markford, D.

    1974-01-01

    The information presented refers to sodium valve development for KNK and SNR-300 as well as for sodium test facilities on the INTERATOM site at Bensberg. Well in advance of KNK-I a number of sodium test facilities have been operated containing small and medium size valves of different design and manufacturer. The more stringent requirements for long range safe and reliable operation in KNK-I put forth a development program for the main primary and secondary circuit sodium valves. Operational experience gave rise to modification of the stem seal arrangement mainly, so KNK-II (which is the fast core for KNK reactor) will be run with modified sodium valves. Main pipe diameters in SNR-300 are in the range of 600 mm. Valve designs with rising shafts would require excessive space in the primary circuit cavities, therefore efforts have been directed towards introduction of different type valves. Due to the requirements of after-heat-removal a valve type with control capability had to be chosen. A special design of butterfly valves was selected for the primary and secondary circuits of SNR-300. The development and tests performed with this type of valve are described. In the field of small sodium valves, tests with a 50 mm diameter freeze-seal valve are reported, and the current status of bellows-seal-valves to be inserted into SNR-300 is discussed. (U.S.)

  17. Aging and malfunction of valves in CANDU special safety systems. Phase 1

    International Nuclear Information System (INIS)

    1989-03-01

    Aging and wear related valve malfunctions have been reported in American nuclear generating systems. This report documents the first attempt to study these phenomena on a global basis in Canadian nuclear power plants. A general methodology outlines an approach to this type of study which is amenable to use within existing information structures. Nuclear regulatory requirements which influence the testing of valves in Canadian nuclear power plants are reviewed. The reporting systems which emanate from these requirements are discussed and sources of valve failure data are reviewed. It is determined that modifications to existing failure reporting systems are required before practical means of collecting data necessary for the analysis of age related valve malfunctions can be developed. In spite of limitations in reported failure data, a partial data base is compiled for valve failures in Special Safety Systems of domestic nuclear plants. Data are reported for the period 1982 to 1986. The valve population and basic parameters of each valve such as type, operator, function, etc., and the reported failures against this population are compiled and reviewed for evidence of time dependent versus random failure trends. Results suggest that there is no clear age related failure trend. In fact, some systems and stations, experienced a reduction in failure rates with years of servicing, suggesting that some earlier generic valve problems may have been solved. Present inspection, test, and maintenance practices are reviewed and their effectiveness for purposes of predicting or preventing incipient failures is assessed to be of moderate value. Modern failure prevention methods are highlighted and their applicability discussed

  18. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  19. Prediction of critical flow rates through power-operated relief valves

    International Nuclear Information System (INIS)

    Abdollahian, D.; Singh, A.

    1983-01-01

    Existing single-phase and two-phase critical flow models are used to predict the flow rates through the power-operated relief valves tested in the EPRI Safety and Relief Valve test program. For liquid upstream conditions, Homogeneous Equilibrium Model, Moody, Henry-Fauske and Burnell two-phase critical flow models are used for comparison with data. Under steam upstream conditions, the flow rates are predicted either by the single-phase isentropic equations or the Homogeneous Equilibrium Model, depending on the thermodynamic condition of the fluid at the choking plane. The results of the comparisons are used to specify discharge coefficients for different valves under steam and liquid upstream conditions and evaluate the existing approximate critical flow relations for a wide range of subcooled water and steam conditions

  20. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  1. Miniaturized Low-Power Piezo Microvalve for NanoSat and CubeSat Propulsion, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In the Phase I effort, Busek developed a miniature precision piezo-actuated microvalve weighing 32g and occupying 4.5 cm^3. The valve demonstrated continuous flow...

  2. Treatment of hydrocephalus determined by the European Orbis Sigma Valve II survey: a multicenter prospective 5-year shunt survival study in children and adults in whom a flow-regulating shunt was used

    NARCIS (Netherlands)

    Hanlo, Patrick W.; Cinalli, Giuseppe; Vandertop, W. Peter; Faber, Joop A. J.; Bøgeskov, Lars; Børgesen, Svend E.; Boschert, Jürgen; Chumas, Paul; Eder, Hans; Pople, Ian K.; Serlo, Willy; Vitzthum, Eckehard

    2003-01-01

    OBJECT: The goal of this study was to evaluate the long-term results of a flow-regulating shunt (Orbis Sigma Valve [OSV] II Smart Valve System; Integra NeuroSciences, Sophia Antipolis, France) in the treatment of hydrocephalus, whether it was a first insertion procedure or surgical revision of

  3. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  4. A study on modelling of a butterfly-type control valve by a pneumatic actuator

    International Nuclear Information System (INIS)

    Hwang, I Cheol; Park, Cheol Jae

    2009-01-01

    This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.

  5. [Aortic valve-sparing root reconstruction in Marfan syndrome].

    Science.gov (United States)

    Ogino, H; Sasaki, H; Hanafusa, Y; Hirata, M; Numata, S; Ando, M; Yagihara, T; Kitamura, S

    2002-07-01

    The outcome of aortic valve-sparing root reconstruction in Marfan syndrome was reviewed. Thirteen patients with Marfan syndrome underwent aortic valve-sparing root reconstruction for annuloaortic ectasia or aortic root dissection between 1994 and 1999. The grade of preoperative aortic regurgitation was I in 4, II in 2, III in 5, IV in 2 patients. The procedures of aortic valve-sparing were reimplantation in 7 and remodeling in 5 patients. There was no hospital and late death. Recurrence of aortic regurgitation greater than moderate grade developed in 1 patient immediately after the surgery and in the other 4 patients in the late stage. One patient of them required aortic valve replacement for it. Aortic valve-sparing root reconstruction is applicable in Marfan patients, although the indication should be cautious. Close observation is needed for recurrence of aortic regurgitation.

  6. First results from GERDA Phase II

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-09-01

    Gerda is designed for a background-free search of 76Ge neutrinoless double-β decay, using bare Ge detectors in liquid Ar. The experiment was upgraded after the successful completion of Phase I to double the target mass and further reduce the background. Newly-designed Ge detectors were installed along with LAr scintillation sensors. Phase II of data-taking started in Dec 2015 with approximately 36 kg of Ge detectors and is currently ongoing. The first results based on 10.8 kg· yr of exposure are presented. The background goal of 10-3 cts/(keV· kg· yr) is achieved and a search for neutrinoless double-β decay is performed by combining Phase I and II data. No signal is found and a new limit is set at T1/20ν > 5.3 \\cdot {1025} yr (90% C.L.).

  7. Hemodynamics in the Valsalva sinuses after transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Ducci, Andrea; Tzamtzis, Spyridon; Mullen, Michael J; Burriesci, Gaetano

    2013-09-01

    The study aim was to assess, in vitro, the hemodynamic modifications produced by transcatheter valves in the Valsalva sinuses, by mean of phase-resolved particle image velocimetry (PIV) measurements. Flow measurements were performed on a glass mock aortic root that included three polymeric valve leaflets, before and after the implantation of a Medtronic CoreValve device and of an Edwards SAPIEN valve. All experiments were carried out in a hydro-mechanical cardiovascular pulse duplicator system (Vivitro Superpump System SP3891) that reproduced physiologically equivalent pressures and flow rates conforming to the requirements of the standard ISO 5840:2005. The flow dynamics, before and after implantation of the two prosthetic devices, was characterized on the basis of phase-resolved velocity field and viscous shear rate measurements. Direct comparison indicated that both transcatheter valves determined a significant variation of flow during the early stages of valve opening and during valve closure. In general, the presence of the two valve implants significantly reduced the flow activity in the Valsalva sinuses, promoting regions of stagnation at their base. The reduction in flow in the Valsalva sinuses could be associated with the higher incidence of ischemic events reported after transcatheter heart valve implantation.

  8. SIMMER-II analysis of transition-phase experiments

    International Nuclear Information System (INIS)

    Wehner, T.R.; Bell, C.R.

    1985-01-01

    Analyses of Los Alamos transition-phase experiments with the SIMMER-II computer code are reported. These transient boilup experiments simulated the recriticality-induced transient motion of a boiling pool of molten fuel, molten steel and steel vapor, within a subassembly duct in a liquid-metal fast breeder reactor during the transition phase of a core-disruptive accident. The two purposes of these experiments were to explore and reach a better understanding of fast reactor safety issues, and to provide data for SIMMER-II verification. Experimental data, consisting of four pressure traces and a high-speed movie, were recorded for four sets of initial conditions. For three of the four cases, SIMMER-II-calculated pressures compared reasonably well with the experimental pressures. After a modification to SIMMER-II's liquid-vapor drag correlation, the comparison for the fourth case was reasonable also. 12 refs., 4 figs

  9. Very long-term results (more than 20 years) of valve repair with carpentier's techniques in nonrheumatic mitral valve insufficiency.

    Science.gov (United States)

    Braunberger, E; Deloche, A; Berrebi, A; Abdallah, F; Celestin, J A; Meimoun, P; Chatellier, G; Chauvaud, S; Fabiani, J N; Carpentier, A

    2001-09-18

    Mitral valve repair is considered the gold standard in surgery of degenerative mitral valve insufficiency (MVI), but the long-term results (>20 years) are unknown. We reviewed the first 162 consecutive patients who underwent mitral valve repair between 1970 and 1984 for MVI due to nonrheumatic disease. The cause of MVI was degenerative in 146 patients (90%) and bacterial endocarditis in 16 patients (10%). MVI was isolated or, in 18 cases, associated with tricuspid insufficiency. The mean age of the 162 patients (104 men and 58 women) was 56+/-10 years (age range 22 to 77 years). New York Heart Association functional class was I, II, III, and IV in 2%, 39%, 52%, and 7% of patients, respectively. The mean cardiothoracic ratio was 0.58+/-0.07 (0.4 to 0.8), and 72 (45%) patients had atrial fibrillation. Valve analysis showed that the main mechanism of MVI was type II Carpentier's functional classification in 152 patients. The leaflet prolapse involved the posterior leaflet in 93 patients, the anterior leaflet in 28 patients, and both leaflets in 31 patients. Surgical technique included a Carpentier's ring annuloplasty in all cases, a valve resection in 126 patients, and shortening or transposition of chordae in 49 patients. During the first postoperative month, there were 3 deaths (1.9%) and 3 reoperations (2 valve replacements and 1 repeat repair [1.9%]). Six patients were lost to follow-up. The remaining 151 patients with mitral valve repair were followed during a median of 17 years (range 1 to 29 years; 2273 patient-years). The 20-year Kaplan-Meier survival rate was 48% (95% CI 40% to 57%), which is similar to the survival rate for a normal population with the same age structure. The 20-year rates were 19.3% (95% CI 11% to 27%) for cardiac death and 26% (95% CI 17% to 35%) for cardiac morbidity/mortality (including death from a cardiac cause, stroke, and reoperation). During the 20 years of follow-up, 7 patients were underwent surgery at 3, 7, 7, 8, 8, 10, or 12

  10. 40 CFR 73.20 - Phase II early reduction credits.

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 16 2010-07-01 2010-07-01 false Phase II early reduction credits. 73.20 Section 73.20 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY (CONTINUED) AIR PROGRAMS (CONTINUED) SULFUR DIOXIDE ALLOWANCE SYSTEM Allowance Allocations § 73.20 Phase II early reduction credits...

  11. Predictors of Paravalvular Regurgitation After Implantation of the Fully Repositionable and Retrievable Lotus Transcatheter Aortic Valve (from the REPRISE II Trial Extended Cohort).

    Science.gov (United States)

    Blackman, Daniel J; Meredith, Ian T; Dumonteil, Nicolas; Tchétché, Didier; Hildick-Smith, David; Spence, Mark S; Walters, Darren L; Harnek, Jan; Worthley, Stephen G; Rioufol, Gilles; Lefèvre, Thierry; Houle, Vicki M; Allocco, Dominic J; Dawkins, Keith D

    2017-07-15

    Paravalvular leak (PVL) after transcatheter aortic valve replacement is associated with worse long-term outcomes. The Lotus Valve incorporates an innovative Adaptive Seal designed to minimize PVL. This analysis evaluated the incidence and predictors of PVL after implantation of the Lotus transcatheter aortic valve. The REPRISE II (REpositionable Percutaneous Replacement of Stenotic Aortic Valve through Implantation of Lotus Valve System - Evaluation of Safety and Performance) Study With Extended Cohort enrolled 250 high-surgical risk patients with severe symptomatic aortic stenosis. Aortic regurgitation was assessed by echocardiography pre-procedure, at discharge and 30 days, by an independent core laboratory. Baseline and procedural predictors of mild or greater PVL at 30 days (or at discharge if 30-day data were not available) were determined using a multivariate regression model (n = 229). Of the 229 patients, 197 (86%) had no/trace PVL, 30 had mild, and 2 had moderate PVL; no patient had severe PVL. Significant predictors of mild/moderate PVL included device:annulus area ratio (odds ratio [OR] 0.87; 95% CI 0.83 to 0.92; p 10% annular oversizing by area were 17.5% (11 of 63), 2.9% (2 of 70), and 3.2% (2 of 63), respectively. Significant independent predictors of PVL included device:annulus area ratio and left ventricular outflow tract calcium volume. When the prosthetic valve was oversized by ≥5%, the rate of mild or greater PVL was only 3%. In conclusion, the overall rates of PVL with the Lotus Valve are low and predominantly related to device/annulus areas and calcium; these findings have implications for optimal device sizing. Copyright © 2017 Elsevier Inc. All rights reserved.

  12. The Gerda Phase II detector assembly

    Energy Technology Data Exchange (ETDEWEB)

    Bode, Tobias; Schoenert, Stefan [Physik-Department E15, Technische Universitaet Muenchen (Germany); Schwingenheuer, Bernhard [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    Phase II of the Gerda (Germanium Detector Array) experiment will continue the search for the neutrinoless double beta decay (0νββ) of {sup 76}Ge. Prerequisites for Phase II are an increased target mass and a reduced background index of < 10 {sup -3} cts/(keV.kg.yr). Major hardware upgrades to achieve these requirements are scheduled for 2013. They include the deployment of a new radio pure low mass detector assembly. The structural properties of available radio-pure materials and reduction of mass necessitate a change of the electrical contacting used to bias and read-out the detectors. The detector assembly design and the favored contacting solution are presented.

  13. Studies of valve lifter for automotive heavy duty diesel engine by ceramic materials. II. Development of SiC valve lifter by injection molding method

    Energy Technology Data Exchange (ETDEWEB)

    Yun, H W [Technical Centre of KIA-ASIA MOTORS (Korea, Republic of); Han, I S [Korea Institute of Energy Research, Tajeon (Korea, Republic of); Lim, Y S; Chung, Y J [Myong Ji University (Korea, Republic of)

    1998-02-01

    Valve lifter, namely tappet, is supported by lifter hole which is located upper side of camshaft in cylinder block, transforms rotatic movement of camshaft into linear movement and helps to open and shut the engine valve as an engine parts. The face of valve lifter, which is continuously contacting with camshaft, brings about abnormal wears, such as unfair wear and early wear, because it is severely loaded in the valve train system. These wears act as a defect like over-clearance and cause imperfect combustion of fuel during the valve lifting in the combustion chamber. Consequently, this imperfect combustion makes the engine out-put decrease and has cause on air pollution. To prevent these wears, therefore, the valve lifter cast in metal developed into SiC ceramics valve lifter which has an excellence in wear and impact resistance. As a result, the optimum process conditions like injection condition, mixture ratio and debonding process could be established. After sintering, fine-sinered dual microstructure in which prior {alpha}-SiC, carbon and silicon was obtained. Based on the new SiC({beta}-SiC) produced by reaction among the {alpha}-SiC, carbon and silicon was obtained. Based on the study, it is verified that mechanical properties of SiC valve lifter are excellent in Vickers hardness 1100{approx}1200 bending strength (300{approx}350 Pa), fracture toughness (1.5{approx}1.7 MPacentre dotm{sup 1/2}). Through engine dynamo testing, SiC valve lifter and metal valve lifter are examined and compared into abnormal phenomena such early fracture, unfair and early wear. It is hoped that this research will serve as an important springboard for the future study of heavy duty diesel engine parts developed by ceramics which has a good wear resistance, reliability, and lightability.

  14. Low intake valve lift in a port fuel-injected engine

    Energy Technology Data Exchange (ETDEWEB)

    Begg, S.M.; Hindle, M.P.; Cowell, T.; Heikal, M.R. [The Sir Harry Ricardo Laboratories, Centre for Automotive Engineering, Cockcroft Building, University of Brighton, Lewes Road, Brighton, East Sussex, BN2 4GJ (United Kingdom)

    2009-12-15

    A phenomenological study of the airflow and fuel spray interaction in a variable valve gasoline engine is presented. Experiments were performed in a steady-state flow rig fitted with a modified production cylinder head. The intake valve lift was varied manually. The mass flow rates of air and fuel through the test rig were adjusted to match typical engine operating conditions. Particle Image Velocimetry (PIV) and Laser Doppler Anemometry (LDA) measurements of the airflow showed the breakdown of a single, forward tumbling vortex-like structure into a pair of high-speed, turbulent jets at low valve lifts. Two transitional phases in the flow at the valve gap were identified for valve lifts less than 1.5 mm and greater than 3 mm. At the lower limit, a jet flapping instability was recorded. A port fuel injector (PFI) spray was characterised in a quiescent, chamber and within the test rig. High Speed Photography (HSP) and Phase Doppler Anemometry (PDA) were used to measure the effects of varying valve lift upon the fuel droplet characteristics. The in-cylinder measurements showed a reduction in mean droplet diameter of up to 50%, close to the valve gap, for peak valve lifts of less than 3 mm. (author)

  15. Design of clinical trials Phase I and II with radiopharmaceuticals

    International Nuclear Information System (INIS)

    Giannone, C.A.; Soroa, V.E.

    2015-01-01

    We presented some usual designs for clinical studies in Phase I and Phase II. For Phase I we considered the 3 + 3 Classic design, designs with accelerated titration and those with dose escalation schemes with overdose control (EWOC). For Phase II designs with efficacy outcomes are presented. The design proposed by Fleming is discussed as well as those with inclusion of patients in two stages: Gehan’s design and the Optimal two–stage Simon’s design. We also discussed the design of combined endpoints of efficacy and safety of Bryant and Day with an application example of therapeutically Lu-177. Finally some proposals for phase II trials with control group are considered. (authors) [es

  16. The influence of Marfans and bicuspid valves on outcomes following aortic valve reimplantation.

    Science.gov (United States)

    Martín, Carlos E; García Montero, Carlos; Serrano, Santiago-Fiz; González, Ana; Mingo, Susana; Moñivas, Vanessa; Centeno, Jorge; Forteza, Alberto

    2017-10-01

    We analyzed our early and midterm results with aortic valve reimplantation surgery to determine the influence of Marfan syndrome and bicuspid valves on outcomes with this technique. Between March 2004 and December 2015, 267 patients underwent aortic valve reimplantation operations. The mean diameter of the sinuses of Valsalva was 50 ± 3 mm and moderate/severe aortic regurgitation was present in 34.4% of these patients. A bicuspid aortic valve was present in 21% and 40% had Marfan syndrome. Overall 30-day mortality was 0.37% (1/267). Mean follow-up was 59.7 ± 38.7 months. Overall survival at 1, 3, and 5 years was 98 ± 8%, 98 ± 1%, and 94 ± 2%, respectively. Freedom from reoperation and aortic regurgitation >II was 99 ± 5%, 98 ± 8%, 96.7 ± 8%, and 99 ± 6%, 98 ± 1%, 98 ± 1%, respectively at 1, 3, and 5 years follow-up, with no differences between Marfan and bicuspid aortic valve groups. (p = 0.94 and p = 0.96, respectively). No endocarditis or thromboembolic complications were documented, and 93.6% of the patients did not receive any anticoagulation therapy. The reimplantation technique for aortic root aneurysms is associated with excellent clinical and functional outcomes at short and mid-term follow-up. © 2017 Wiley Periodicals, Inc.

  17. Left atrial isolation associated with mitral valve operations.

    Science.gov (United States)

    Graffigna, A; Pagani, F; Minzioni, G; Salerno, J; Viganò, M

    1992-12-01

    Surgical isolation of the left atrium was performed for the treatment of chronic atrial fibrillation secondary to valvular disease in 100 patients who underwent mitral valve operations. From May 1989 to September 1991, 62 patients underwent mitral valve operations (group I); 19, mitral valve operations and DeVega tricuspid annuloplasty (group II); 15, mitral and aortic operations (group III); and 4, mitral and aortic operations and DeVega tricuspid annuloplasty (group IV). Left atrial isolation was performed, prolonging the usual left paraseptal atriotomy toward the left fibrous trigone anteriorly and the posteromedial commissure posteriorly. The incision was conducted a few millimeters apart from the mitral valve annulus, and cryolesions were placed at the edges to ensure complete electrophysiological isolation of the left atrium. Operative mortality accounted for 3 patients (3%). In 79 patients (81.4%) sinus rhythm recovered and persisted until discharge from the hospital. No differences were found between the groups (group I, 80.7%; group II, 68.5%; group III, 86.7%; group IV, 75%; p = not significant). Three late deaths (3.1%) were registered. Long-term results show persistence of sinus rhythm in 71% of group I, 61.2% of group II, 85.8% of group III, and 100% of group IV. The unique risk factor for late recurrence of atrial fibrillation was found to be preoperative atrial fibrillation longer than 6 months. Due to the satisfactory success rate in recovering sinus rhythm, we suggest performing left atrial isolation in patients with chronic atrial fibrillation undergoing valvular operations.

  18. HPC Benchmark Suite NMx, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In the phase II effort, Intelligent Automation Inc., (IAI) and University of Central Florida (UCF) propose to develop a comprehensive numerical test suite for...

  19. Horonobe Underground Research Laboratory project. Synthesis of phase II (construction phase) investigations to a depth of 350 m

    International Nuclear Information System (INIS)

    Sato, Toshinori; Sasamoto, Hiroshi; Ishii, Eiichi; Matsuoka, Toshiyuki; Hayano, Akira; Miyakawa, Kazuya; Fujita, Tomoo; Tanai, Kenji; Nakayama, Masashi; Takeda, Masaki; Yokota, Hideharu; Aoyagi, Kazuhei; Ohno, Hirokazu; Shigeta, Naotaka; Hanamuro, Takahiro; Ito, Hiroaki

    2017-03-01

    The Horonobe Underground Research Laboratory (URL) Project is being pursued by the Japan Atomic Energy Agency (JAEA) to enhance the reliability of relevant disposal technologies through investigations of the deep geological environment within the host sedimentary formations at Horonobe, northern Hokkaido. The project consists of two major research areas, 'Geoscientific Research' and 'R and D on Geological Disposal', and proceeds in three overlapping phases, 'Phase I: Surface-based investigation', 'Phase II: Construction' and 'Phase III: Operation', over a period of 20 years. This report summarizes the results of the Phase II investigations carried out from April 2005 to June 2014 to a depth of 350 m. Integration of work from different disciplines into a 'geosynthesis' ensures that the Phase II goals have been successfully achieved and identifies key issues that need to be addressed in the Phase II investigations. Efforts are made to summarize as many lessons learnt from the Phase II investigations and other technical achievements as possible to form a 'knowledge base' that will reinforce the technical basis for both implementation and the formulation of safety regulations. (author)

  20. Crew Cerebral Oxygen Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II SBIR proposal is aimed at developing a non-invasive, optical method for monitoring crew member state of awareness in operational environments. All...

  1. Phase II Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Schuknecht, Nate [Project Manager; White, David [Principle Investigator; Hoste, Graeme [Research Engineer

    2014-09-11

    The SkyTrough DSP will advance the state-of-the-art in parabolic troughs for utility applications, with a larger aperture, higher operating temperature, and lower cost. The goal of this project was to develop a parabolic trough collector that enables solar electricity generation in the 2020 marketplace for a 216MWe nameplate baseload power plant. This plant requires an LCOE of 9¢/kWhe, given a capacity factor of 75%, a fossil fuel limit of 15%, a fossil fuel cost of $6.75/MMBtu, $25.00/kWht thermal storage cost, and a domestic installation corresponding to Daggett, CA. The result of our optimization was a trough design of larger aperture and operating temperature than has been fielded in large, utility scale parabolic trough applications: 7.6m width x 150m SCA length (1,118m2 aperture), with four 90mm diameter × 4.7m receivers per mirror module and an operating temperature of 500°C. The results from physical modeling in the System Advisory Model indicate that, for a capacity factor of 75%: The LCOE will be 8.87¢/kWhe. SkyFuel examined the design of almost every parabolic trough component from a perspective of load and performance at aperture areas from 500 to 2,900m2. Aperture-dependent design was combined with fixed quotations for similar parts from the commercialized SkyTrough product, and established an installed cost of $130/m2 in 2020. This project was conducted in two phases. Phase I was a preliminary design, culminating in an optimum trough size and further improvement of an advanced polymeric reflective material. This phase was completed in October of 2011. Phase II has been the detailed engineering design and component testing, which culminated in the fabrication and testing of a single mirror module. Phase II is complete, and this document presents a summary of the comprehensive work.

  2. Improved Metal-Polymeric Laminate Radiation Shielding, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this proposed Phase II program, builds on the phase I feaibility where a multifunctional lightweight radiation shield composite was developed and fabricated. This...

  3. Performance of BEGe detectors for GERDA Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Lazzaro, Andrea [Physik-Department E15, Technische Universitaet Muenchen (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    After the end of the data-taking for GERDA Phase I, the apparatus has been upgraded to fulfill the requirements of the second phase. Phase II sensitivity will be driven by 30 custom made BEGe detectors. This detectors are now available and can be operated in phaseII configuration in the GERDA cryostat together with the liquid argon scintillation veto. The performances of BEGe detectors in liquid argon are presented in this talk. Besides the spectroscopy capability, the focus will be placed on the expectations in terms of background rejection via pulse shape discrimination (PSD). In particular the main goal the BEGe's pulse shape analysis is to discriminate surface events produced by beta emitters (e.g. {sup 42}K) present in the liquid Ar.

  4. Innovation in the Sky, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II proposal presents a scope of work to develop reliable Sense and Avoid for BVLOS Unmanned Aerial Vehicle [UAV] operations. We first analyze a) the...

  5. Classification of the radiological morphology of the mitral valve

    International Nuclear Information System (INIS)

    Spindola-Franco, H.; Bjork, L.; Adams, D.F.; Abrams, H.L.

    1980-01-01

    The morphology of the mitral valve apparatus was assessed on 100 normal left ventriculograms. Four distinct types of mitral valve were identified according to the position of the mitral fulcrum (the point of attachment of the leaflets to the annulus) and the configuration of the adjacent left ventricular wall (left ventricular fornix) during diastole. Types I and II closely simulated prolapse of the mitral valve (pseudoprolapse) in the right anterior oblique projection during the ejection period. Measurements showed that contraction of the ventricle failed to reduce the diameter of the mitral annulus in 26 per cent of normal left ventricles. (U.K.)

  6. Kursk Operation Simulation and Validation Exercise - Phase II (KOSAVE II)

    National Research Council Canada - National Science Library

    Bauman, Walter

    1998-01-01

    ... (KOSAVE) Study (KOSAVE II) documents, in this report a statistical record of the Kursk battle, as represented in the KDB, for use as both a standalone descriptive record for historians, and as a baseline for a subsequent Phase...

  7. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  8. Survival and freedom from aortic valve-related reoperation after valve-sparing aortic root replacement in 1015 patients.

    Science.gov (United States)

    Kari, Fabian A; Doll, Kai-Nicolas; Hemmer, Wolfgang; Liebrich, Markus; Sievers, Hans-Hinrich; Richardt, Doreen; Reichenspurner, Hermann; Detter, Christian; Siepe, Matthias; Czerny, Martin; Beyersdorf, Friedhelm

    2016-04-01

    The aim of this study was to characterize mortality and aortic valve replacement after valve-sparing aortic root replacement (V-SARR) in a multicentre cohort. Between 1994 and 2014, 1015 patients had V-SARR with (n = 288, 28%) or without cusp/commissure repair (n = 727, 72%) at the centres of Lübeck (n = 343, 34%), Stuttgart (n = 346, 34%), Hamburg (n = 109, 11%) and Freiburg (n = 217, 21%), Germany. Comparative survival of an age- and gender-matched general population was calculated. Log-rank tests and multiple logistic regression were used to identify risk factors. The mean follow-up was 5.2 ± 3.9 years. Cumulative follow-up comprised 2933 patient-years. Early survival was 98%. NYHA status and aneurysm size were predictive of death during mid-term follow-up (P = 0.025). Freedom from aortic valve replacement was 90% at 8 years, with the type of V-SARR (root remodelling, David II) being a risk factor (P = 0.015). Bicuspid aortic valve (P = 0.26) and initial valve function (P = 0.4) did not impact reoperation. The need of additional valve repair (cusps/commissures) was not linked to reoperation: freedom from aortic valve replacement at 8 years was 84% if cusp repair was performed versus 90% if V-SARR alone was performed (P = 0.218). Marfan syndrome had no impact on survival or on aortic valve replacement. Mid-term survival of patients after V-SARR is comparable with that of a matched general population. The regurgitant bicuspid aortic valve is a favourable substrate for V-SARR. Prophylactic surgery should be performed before symptoms or large aneurysms are present to achieve optimal mid-term outcomes. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  9. Nano-Phase Powder Based Exothermic Braze Repair Technology For RCC Materials, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase II project will advance innovative, cost effective and reliable nano-phase exothermic RCC joining processes (ExoBrazeTM) in order to be able to reinforce...

  10. SOLA-LOOP analysis of a back pressure check valve

    International Nuclear Information System (INIS)

    Travis, J.R.

    1984-01-01

    The SOLA-LOOP computer code for transient, nonequilibrium, two-phase flows in networks has been coupled with a simple valve model to analyze a feedwater pipe breakage with a back-pressure check valve. Three tests from the Superheated Steam Reactor Safety Program Project (PHDR) at Kahl, West Germany, are analyzed, and the calculated transient back-pressure check valve behavior and fluid dynamics effects are found to be in excellent agreement with the experimentally measured data

  11. Troca valvar aórtica com diferentes próteses: existem diferenças nos resultados da fase hospitalar? Aortic valve replacement with different types of prosthesis: are there differences in the outcomes during hospital phase?

    Directory of Open Access Journals (Sweden)

    Gibran Roder Feguri

    2008-12-01

    Full Text Available OBJETIVOS: Analisar dados intra-operatórios e possíveis diferenças na evolução clínica da fase hospitalar de pós-operatório da troca valvar aórtica com diferentes próteses. MÉTODOS: Análise de 60 pacientes, divididos em três grupos: os submetidos a troca valvar por prótese biológica (20; por prótese mecânica (20; e finalmente, por valva homóloga (20. A média da idade foi de 51,1 anos; 60% eram do sexo masculino e 40% do feminino; 86,7% estavam em NYHA II ou III; 63,3% eram hipertensos, 18,3% diabéticos; a etiologia valvar foi degenerativa em 39%, reumática em 36% e endocardite em 15%. RESULTADOS: A mortalidade hospitalar foi de 5%; não houve diferenças entre os grupos na incidência de choque séptico ou cardiogênico, insuficiência renal aguda, arritmias no centro cirúrgico e na unidade de terapia intensiva (UTI, assim como para o tempo de internação na UTI e tempo de ventilação mecânica. Houve diferença estatística nos tempos de circulação extracorpórea (P=0,02 e pinçamento aórtico (POBJECTIVE: To analyze intraoperative data and possible differences in clinical evolution during postoperative hospital phase for aortic valve replacement surgery using different types of prosthesis. METHODS: Analysis of 60 patients divided into three groups. Valve replacement with bioprosthesis (20, mechanical prosthesis (20 and homologous valve (20. The mean age was 51.1, 60% were male and 40% female patients; 86.7 % were in NYHA II or III; 63.3% presented arterial hypertension and 18.3% had diabetes. Aetiology of valve disease was degenerative for 39%, rheumatic for 36% and endocardits for 15%. RESULTS: The hospital mortality was 5%; there were no differences in the incidence of septical or cardiogenic shock, acute renal failure, rhythms disorders during surgery or intensive care, neither for total time in intensive care and mechanical ventilation. However, there was statistical differences as regards the cardiopulmonary

  12. First results of GERDA Phase II and consistency with background models

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode1, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevzik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-01-01

    The GERDA (GERmanium Detector Array) is an experiment for the search of neutrinoless double beta decay (0νββ) in 76Ge, located at Laboratori Nazionali del Gran Sasso of INFN (Italy). GERDA operates bare high purity germanium detectors submersed in liquid Argon (LAr). Phase II of data-taking started in Dec 2015 and is currently ongoing. In Phase II 35 kg of germanium detectors enriched in 76Ge including thirty newly produced Broad Energy Germanium (BEGe) detectors is operating to reach an exposure of 100 kg·yr within about 3 years data taking. The design goal of Phase II is to reduce the background by one order of magnitude to get the sensitivity for T1/20ν = O≤ft( {{{10}26}} \\right){{ yr}}. To achieve the necessary background reduction, the setup was complemented with LAr veto. Analysis of the background spectrum of Phase II demonstrates consistency with the background models. Furthermore 226Ra and 232Th contamination levels consistent with screening results. In the first Phase II data release we found no hint for a 0νββ decay signal and place a limit of this process T1/20ν > 5.3 \\cdot {1025} yr (90% C.L., sensitivity 4.0·1025 yr). First results of GERDA Phase II will be presented.

  13. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  14. Aortic valve-sparing surgery in Marfan syndrome.

    Science.gov (United States)

    Nachum, Eyal; Shinfeld, Amichay; Kogan, Alexander; Preisman, Sergey; Levin, Shany; Raanani, Ehud

    2013-08-01

    Patients with Marfan syndrome are referred for cardiac surgery due to root aneurysm with or without aortic valve regurgitation. Because these patients are young and frequently present with normal-appearing aortic cusps, valve sparing is often recommended. However, due to the genetic nature of the disease, the durability of such surgery remains uncertain. Between February 2004 and June 2012, 100 patients in our department suffering from aortic aneurysm with aortic valve regurgitation underwent elective aortic valve-sparing surgery. Of them, 30 had Marfan syndrome, were significantly younger (30 +/- 13 vs. 53 +/- 16 years), and had a higher percentage of root aneurysm, compared with ascending aorta aneurysm in their non-Marfan counterparts. We evaluated the safety, durability, clinical and echocardiographic mid-term results of these patients. While no early deaths were reported in either group, there were a few major early complications in both groups. At follow-up (reaching 8 years with a mean of 34 +/- 26 months) there were no late deaths, and few major late complications in the Marfan group. Altogether, 96% and 78% of the patients were in New York Heart Association functional class I-II in the Marfan and non-Marfan groups respectively. None of the Marfan patients needed reoperation on the aortic valve. Freedom from recurrent aortic valve regurgitation > 3+ was 94% in the Marfan patients. Aortic valve-sparing surgery in Marfan symdrome patients is safe and yields good mid-term clinical outcomes.

  15. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  16. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  17. Water hammer caused by closure of turbine safety spherical valves

    Science.gov (United States)

    Karadžić, U.; Bergant, A.; Vukoslavčević, P.

    2010-08-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  18. Water hammer caused by closure of turbine safety spherical valves

    International Nuclear Information System (INIS)

    Karadzic, U; Vukoslavcevic, P; Bergant, A

    2010-01-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  19. Water hammer caused by closure of turbine safety spherical valves

    Energy Technology Data Exchange (ETDEWEB)

    Karadzic, U; Vukoslavcevic, P [Faculty of Mechanical Engineering, University of Montenegro Dzordza Vasingtona nn, Podgorica, 81000 (Montenegro); Bergant, A, E-mail: uros.karadzic@ac.m [LitostrojPower d.o.o., Litostrojska 50, Ljubljana, 1000 (Slovenia)

    2010-08-15

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  20. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  1. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  2. Single Electron Transistor Platform for Microgravity Proteomics, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II program builds from the successful Phase I efforts to demonstrate that Quantum Logic Devices' nanoelectronic platform for biological detection could...

  3. U10 : Trusted Truck(R) II (phase B).

    Science.gov (United States)

    2009-01-01

    Phase B of the Trusted Truck II project built on the system developed in Phase A (or Year 1). For the implementation portion of the project, systems were added to the trailer to provide additional diagnostic trailer data that can be sent to the TTM...

  4. Durability of lightweight concrete : Phase II : wetting and drying tests, Phase III : freezing and thawing tests.

    Science.gov (United States)

    1966-12-01

    This report describes a laboratory research program on the durability of lightweight concrete. Two phases of a three phase study are covered by this report, while the remaining phase is still under study. The two phases being reported are Phase II - ...

  5. Murine Automated Urine Sampler (MAUS), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II effort involves the development of a novel rodent spaceflight habitat, focusing on care and monitoring of mice for gravitational physiology...

  6. A study of fluid flow and combustion with variable valve timing

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, F

    1998-10-01

    The effects of variable valve timing (VVT) were examined by in-cylinder Laser Doppler Velocimetry flow measurements and heat-release calculations. A single-cylinder Volvo B5254 engine was used for all experiments and the valve timing was altered by phasing or exchanging the camshaft. Special cam lobes were developed for simulation of throttle-less operation. With the standard double camshaft, a tumbling flow was generated and with valve deactivation, a swirling flow was generated. The turbulence was increased with valve deactivation. This increased the combustion rate making lean burn possible. The standard camshaft with inlet valve deactivation and late cam phasing had a faster combustion at {lambda} = 1.8 than the standard camshaft with normal cam phasing at {lambda} = 1.0. Early and late inlet valve closing was used for enabling throttle-less operation. Early inlet valve closing (EIVC) generated a very slow tumble with low turbulence. Late inlet valve closing generated both very high and low turbulence. The net indicated efficiency was improved with up to 10%. Some reduction was observed for the gross indicated efficiency, due to a too large reduction in effective compression ratio. A very stable combustion was obtained for EIVC with gasoline, possibly due to a sheering flow over the inlet valves resulting in improved fuel-air preparation. Wavelet analysis was used for dividing LDV flow measurements into time and frequency resolved information. The technique rendered the same flow results as the moving window technique, but with a separation of the turbulence into different frequencies. The choice of wavelet was shown not to be crucial. The frequency resolved turbulence was studied for tumble and swirl. A tumbling flow had a larger transfer of energy from low frequency turbulence into high frequency turbulence than a swirling flow. This is caused by the tumble breakdown. A correlation against heat-release indicated that high frequency turbulence have a larger

  7. High Resolution Autostereoscopic Cockpit Display, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — During this Phase II program Dimension Technologies Inc. (DTI) proposes to design and build an autostereoscopic (glasses-free 3D) LCD based aircraft cockpit display...

  8. Mid- to long-term outcome comparison of the Medtronic Hancock II and bi-leaflet mechanical aortic valve replacement in patients younger than 60 years of age: a propensity-matched analysis.

    Science.gov (United States)

    Wang, Yin; Chen, Si; Shi, Jiawei; Li, Geng; Dong, Nianguo

    2016-03-01

    This study aims to compare mid-long-term clinical outcomes between patients younger than 60 years of age undergoing bioprosthetic and mechanical aortic valve replacement. From January 2002 to December 2009, patients younger than 60 years of age who received Medtronic Hancock II porcine bioprostheses were selected and compared with those who received mechanical bi-leaflet valves in the aortic position. A stepwise logistic regression propensity score identified a subset of 112 evenly matched patient-pairs. Mid-long-term outcomes of survival, valve-related reoperations, thromboembolic events and bleeding events were assessed. The follow-up was only 95.1% complete. Fourteen measurable variables were statistically similar for the matched cohort. Postoperative in-hospital mortality was 3.6% (bioprosthetic valves) and 2.7% (mechanical valves) (P = 0.700). Survival at 5 and 10 years was 96.3 and 88.7% for patients receiving bioprosthetic valve replacement versus 96.3 and 87.9% for patients receiving mechanical valve replacement (P = 0.860), respectively. At 5 and 10 years after operations, freedom from valve-related reoperation was 97.2 and 94.8% for patients receiving mechanical valve replacement, and 96.3 and 90.2% for patients receiving bioprosthetic valve replacement (P = 0.296), respectively. There was no difference between freedom from thromboembolic events (P = 0.528) and bleeding events (P = 0.128) between the matched groups during the postoperative 10 years. In patients younger than 60 years of age undergoing aortic valve replacement, mid-long-term survival rate was similar for patients receiving bioprosthetic versus mechanical valve replacement. Bioprosthetic valves were associated with a trend for a lower risk of anticoagulation treatment and did not have significantly greater likelihood of a reoperation. These findings suggest that a bioprosthetic valve may be a reasonable choice for AVR in patients younger than 60 years of age. © The Author 2015. Published by

  9. Silver Biocide Analysis & Control Device, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Rapid, accurate measurement and process control of silver ion biocide concentrations in future space missions is needed. The purpose of the Phase II program is to...

  10. Performance of the LAr scintillation veto of Gerda Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Physik-Department and Excellence Cluster Universe, Technische Universitaet Muenchen, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2016-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda has been upgraded to Phase II. To reach the aspired background index of ∝10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium detectors, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon photomultipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during Phase II start-up is reported.

  11. Development of an ITER prototype disruption mitigation valve

    Energy Technology Data Exchange (ETDEWEB)

    Czymek, G., E-mail: g.czymek@fz-juelich.de [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, D52425 Jülich (Germany); Giesen, B., E-mail: ingenieurbuero.giesen@gmx.de [IBG, Sibertstr. 22, D-52525 Heinsberg (Germany); Charl, A.; Panin, A.; Hiller, A.; Nicolai, D.; Neubauer, O.; Koslowski, H.R.; Sandri, N. [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, D52425 Jülich (Germany)

    2015-10-15

    Highlights: • An ITER-DMV prototype for 100 bar, D = 80 mm, opening time 3.5 ms, is ready for fabrication. • The vacuum part is sealed against the working gas by stainless steel bellows for 110 bar. • The conical Laval gas outlet allows maximal mass flow rate. • The eddy current drive turn ratio was optimized for low tilting moment. • Polyimide is used for the head sealing, the decelerator and for the bearing of the guide tube. - Abstract: Disruptions in tokamaks seem to be unavoidable. Consequences of disruptions are (i) high heat loads on plasma-facing components, (ii) large forces on the vacuum vessel, and (iii) the generation of runaway electron beams. In ITER, the thermal energy of the plasma needs to be evenly distributed on the first wall in order to prevent melting, forces from vertical displacement events have to be minimized, and the generation of runaway electrons suppressed. Massive gas injection using fast valves is a concept for disruption mitigation which is presently being explored in many tokamaks. Fast disruption mitigation valves based on an electromagnetic eddy current drive have been developed in Jülich since the 1990s and models of various sizes have been built and are in operation in the TEXTOR, MAST, and JET tokamaks. A disruption mitigation valve for ITER is of necessity larger with an estimated injected gas volume of ∼20 kPa m{sup 3}[7] for runaway electron suppression and all materials used have to be resistant to much higher levels of neutron and gamma radiation than in existing tokamaks. During the last 5 years, the concept for an ITER prototype disruption mitigation valve has been developed up to the stage that a fully functional valve could be built and tested. Special emphasis was given to the development and functional testing of some critical items: (i) the injection chamber seal, (ii) the piston seal, (iii) the eddy current drive, and (iv) a braking mechanism to avoid too fast closure of the valve, which could damage

  12. PBFA [Particle Beam Fusion Accelerator] II: The pulsed power characterization phase

    International Nuclear Information System (INIS)

    Martin, T.H.; Turman, B.N.; Goldstein, S.A.

    1987-01-01

    The Particle Beam Fusion Accelerator II, PBFA II, is now the largest pulsed power device in operation. This paper summarizes its first year and a half of operation for the Department of Energy (DOE) Inertial Confinement Fusion (ICF) program. Thirty-six separate modules provide 72 output pulses that combine to form a 100 TW output pulse at the accelerator center. PBFA II was successfully test fired for the first time on December 11, 1985. This test completed the construction phase (Phase 1) within the expected schedule and budget. The accelerator checkout phase then started (Phase 2). The first priority during checkout was to bring the Phase 1 subsystems into full operation. The accelerator was first tested to determine overall system performance. Next, subsystems that were not performing adequately were modified. The accelerator is now being used for ion diode studies. 32 refs

  13. Successful Thrombolysis of Aortic Prosthetic Valve Thrombosis ...

    African Journals Online (AJOL)

    Arun Kumar Agnihotri

    patients with valvular heart disease). Endorsed by the Society of Cardiovascular. Anesthesiologists, Society for Cardiovascular. Angiography and Interventions, and Society of. Thoracic Surgeons. J Am Coll Cardiol. 2008;52(13):e1-142. 5. Elkayam U, Bitar F. Valvular heart disease and pregnancy. Part II: prosthetic valves.

  14. Titanium Heat Pipe Thermal Plane, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II program is to complete the development of the titanium heat pipe thermal plane and establish all necessary steps for production of this...

  15. Space-Ready Advanced Imaging System, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II effort Toyon will increase the state-of-the-art for video/image systems. This will include digital image compression algorithms as well as system...

  16. Malignant pleural mesothelioma: a phase II trial with docetaxel.

    Science.gov (United States)

    Vorobiof, D A; Rapoport, B L; Chasen, M R; Abratt, R P; Cronje, N; Fourie, L; McMichael, G; Hacking, D

    2002-03-01

    Current cytotoxic therapy has been of limited benefit to patients with malignant pleural mesothelioma. Single agent chemotherapy has been extensively evaluated in small series of phase II clinical trials, with disappointing responses. Docetaxel, an effective taxane in the treatment of advanced breast cancer and non-small-cell lung cancer, was administered intravenously at a dose of 100 mg/m2 every 3 weeks to 30 chemotherapy naive patients with malignant pleural mesothelioma in a prospective multi-institutional phase II clinical trial. An objective response rate (partial responses) of 10% was documented. Additionally, 21% of the patients had minor responses (intention-to-treat analysis). Three patients died within 2 weeks post-first cycle of therapy, although only one patient's death was directly attributed to the investigational drug, whilst in the majority of the patients, manageable and treatable toxicities were encountered. In this phase II clinical trial, docetaxel proved to be mildly effective in the treatment of patients with malignant pleural mesothelioma.

  17. Conversion of Phase II Unsteady Aerodynamics Experiment Data to Common Format; TOPICAL

    International Nuclear Information System (INIS)

    Hand, M. M.

    1999-01-01

    A vast amount of aerodynamic, structural, and turbine performance data were collected during three phases of the National Renewable Energy Laboratory's Unsteady Aerodynamics Experiment (UAE). To compare data from the three phases, a similar format of engineering unit data is required. The process of converting Phase II data from a previous engineering unit format to raw integer counts is discussed. The integer count files can then be input to the new post-processing software, MUNCH. The resulting Phase II engineering unit files are in a common format with current and future UAE engineering unit files. An additional objective for changing the file format was to convert the Phase II data from English units to SI units of measurement

  18. Kilowatt isotope power system. Phase II plan. Volume I. Phase II program plan

    International Nuclear Information System (INIS)

    1978-01-01

    The development of a Kilowatt Isotope Power System (KIPS) was begun in 1975 for the purpose of satisfying the power requirements of satellites in the 1980's. The KIPS is a 238 PuO 2 -fueled organic Rankine cycle turbine power system to provide a design output of 500 to 2000 W. Phase II of the overall 3-phase KIPS program is described. This volume presents a program plan for qualifying the organic Rankine power system for flight test in 1982. The program plan calls for the design and fabrication of the proposed flight power system; conducting a development and a qualification program including both environmental and endurance testing, using an electrical and a radioisotope heat source; planning for flight test and spacecraft integration; and continuing ground demonstration system testing to act as a flight system breadboard and to accumulate life data

  19. Reclaimable Thermally Reversible Polymers for AM Feedstock, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — CRG proposes to continue efforts from the 2016 NASA SBIR Phase I topic H5.04 Reclaimable Thermally Reversible Polymers for AM Feedstock. In Phase II, CRG will refine...

  20. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  1. The Value of the SYNTAX Score II in Predicting Clinical Outcomes in Patients Undergoing Transcatheter Aortic Valve Implantation.

    Science.gov (United States)

    Ryan, Nicola; Nombela-Franco, Luis; Jiménez-Quevedo, Pilar; Biagioni, Corina; Salinas, Pablo; Aldazábal, Andrés; Cerrato, Enrico; Gonzalo, Nieves; Del Trigo, María; Núñez-Gil, Iván; Fernández-Ortiz, Antonio; Macaya, Carlos; Escaned, Javier

    2017-11-27

    The predictive value of the SYNTAX score (SS) for clinical outcomes after transcatheter aortic valve implantation (TAVI) is very limited and could potentially be improved by the combination of anatomic and clinical variables, the SS-II. We aimed to evaluate the value of the SS-II in predicting outcomes in patients undergoing TAVI. A total of 402 patients with severe symptomatic aortic stenosis undergoing transfemoral TAVI were included. Preprocedural TAVI angiograms were reviewed and the SS-I and SS-II were calculated using the SS algorithms. Patients were stratified in 3 groups according to SS-II tertiles. The coprimary endpoints were all-cause death and major adverse cardiovascular events (MACE), a composite of all-cause death, cerebrovascular event, or myocardial infarction at 1 year. Increased SS-II was associated with higher 30-day mortality (P=.036) and major bleeding (P=.015). The 1-year risk of death and MACE was higher among patients in the 3rd SS-II tertile (HR, 2.60; P=.002 and HR, 2.66; P<.001) and was similar among patients in the 2nd tertile (HR, 1.27; P=.507 and HR, 1.05; P=.895) compared with patients in the 1st tertile. The highest SS-II tertile was an independent predictor of long-term mortality (P=.046) and MACE (P=.001). The SS-II seems more suited to predict clinical outcomes in patients undergoing TAVI than the SS-I. Increased SS-II was associated with poorer clinical outcomes at 1 and 4 years post-TAVI, independently of the presence of coronary artery disease. Copyright © 2017 Sociedad Española de Cardiología. Published by Elsevier España, S.L.U. All rights reserved.

  2. Outcomes after valve-preserving root surgery for patients with Marfan syndrome.

    Science.gov (United States)

    Kunihara, Takashi; Aicher, Diana; Rodionycheva, Svetlana; Asano, Mitsuru; Tochii, Masato; Sata, Fumihiro; Schäfers, Hans-Joachim

    2012-09-01

    In patients with Marfan syndrome (MFS), valve reimplantation has been proposed as superior to root remodeling. In the present study, both forms of valve-preserving root repair were applied and mid-term results analyzed in MFS patients compared to a propensity score-matched cohort. Among 604 patients who underwent valve-preserving aortic root surgery between 1995 and 2011 at the authors' institution, 33 MFS patients (16 males, 17 females; mean age 31 +/- 12 years) underwent either remodeling (n=21) or reimplantation (n=12). All patients were followed up echocardiographically, and the outcome with regard to late aortic valve regurgitation (AR) grade EII and reoperation on the aortic valve was compared between MFS patients and the matched cohort (n=33). Baseline characteristics and operative data were similar between the groups. Actuarial freedom from AR > or = II at seven years was 86 +/- 8% in MFS patients and 90 +/- 10% in matched non-MFS patients (p = 0.94). Actuarial freedom from reoperation at seven years was 90 +/- 7% in MFS patients and 100% in non-MFS patients (p = 0.79). In Cox's proportional hazard's model, no independent risk factor, including MFS, was found for recurrent AR or reoperation. Within the MFS patients, remodeling and reimplantation provided an almost identical freedom from late AR > or = II and reoperation up to five years postoperatively (p = 0.55 and 0.99, respectively). The stability of valve-preserving aortic root repair was comparable between patients with or without MFS. Both forms of valve-preserving root repair can provide similar mid-term results for MFS patients, primarily according to their root geometry. However, additional long-term follow up data based on a larger number of patients are required to confirm the evidence obtained to date.

  3. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  4. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  5. Neutrinoless double beta decay in GERDA Phase II

    International Nuclear Information System (INIS)

    Macolino, C.

    2014-01-01

    The GERmanium Detector Array, GERDA, is designed to search for neutrinoless double beta (0νββ) decay of 76 Ge and it is installed in the Laboratori Nazionali del Gran Sasso (LNGS) of INFN, Italy. The GERDA experiment has completed the Phase I with a total collected exposure of 21.6 kg yr and a background index (BI) of the order of BI ≃ 10 −2 cts/(keVkg yr). No excess of events from 0νββ decay has been observed and a lower limit on the half-life on the 0νββ decay for 76 Ge has been estimated: T 0ν 1 /2 > 2.1·10 25 yr at 90% CL. The goal of GERDA Phase II is to reach the target sensitivity of T 0ν 1 /2 ≃ 1.4 · 10 26 yr, with an increased total mass of the enriched material and a reduced background level. In this paper the results from GERDA Phase I and the major improvements planned for Phase II are discussed.

  6. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  7. Fluid mechanics of needle valves with rounded components. Part II: Preliminary measurements

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav

    2016-01-01

    Roč. 251, November (2016), s. 52-58 ISSN 0924-4247 R&D Projects: GA ČR GA13-23046S Institutional support: RVO:61388998 Keywords : needle valves * pressure measurements * valves Subject RIV: BK - Fluid Dynamics Impact factor: 2.499, year: 2016 http://ac.els-cdn.com/S092442471630440X/1-s2.0-S092442471630440X-main.pdf?_tid=45acccf4-951f-11e6-a831-00000aab0f02&acdnat=1476787402_bf349ff3cfc7a824c1a01397a9a5b8b3

  8. A steerable/distance enhanced penetrometer delivery system: Phase II. Topical report

    International Nuclear Information System (INIS)

    Amini, A.; Shenhar, J.; Lum, K.D.

    1996-05-01

    This report summarizes the phase II work on the Position Location Device (POLO) for penetrometers. Phase II was carried out to generate an integrated design of a full-scale steerable/distance enhanced penetrometer delivery system. Steering provides for the controlled and directional use of the penetrometer, while vibratory thrusting can provide greater penetration ability

  9. X-ray diffraction study of phase transitions in iron(II) trisnioximate hexadecylboronate clathrochelate complex

    International Nuclear Information System (INIS)

    Vorontsov, I.I.; Antipin, M.Yu.; Dubovik, I.I.; Papkov, V.S.; Potekhin, K.A.; Voloshin, Ya.Z.; Stash, A.I.; Belsky, V.K.

    2001-01-01

    Crystals of the iron(II) nioximate hexadecylboronate clathrochelate complex-FeNx 3 (BHd ) 2 [tris(μ-1,2-cyclohexanedionedioximato-O:O ' )di-n-hexadecyldiborato(2-) - N,'''N''',N''',N''',N''',N ' ]iron(II) - are investigated by differential scanning calorimetry and X-ray diffraction. Two structural phase transitions are revealed at T cr1 = 290(3) K and T cr2 = 190(3) K. The crystal structures of phases I, II, and III are determined by X-ray diffraction analysis at 303, 243, and 153 K, respectively. It is demonstrated that the I ↔ II phase transition is due to a change in the system of translations, and the II ↔ III phase transition is accompanied only by a jumpwise change in the unit cell parameters. The possible mechanisms of phase transitions are discussed in terms of geometry and molecular packing of FeNx 3 (BHd) 2 in all three phases

  10. High Performance Wafer-Based Capillary Electrochromatography, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase II research comprises designing, constructing, and testing a chip-based capillary electrochromatography (CEC) prototype for separation and analysis of...

  11. Pavement performance evaluation, phase II : data collection.

    Science.gov (United States)

    2008-12-01

    Phase I and II of this study tested approximately 1500 rehabilitated pavements (asphalt and PCC) : throughout the State. These pavements ranged from 5 to 15 years old and were intended to develop a : snapshot of how various rehabilitations were perfo...

  12. Platelet thrombosis in cardiac-valve prostheses

    International Nuclear Information System (INIS)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs

  13. Platelet thrombosis in cardiac-valve prostheses

    Energy Technology Data Exchange (ETDEWEB)

    Dewanjee, M.K.

    1989-01-01

    The contribution of platelets and clotting factors in thrombosis on cardiovascular prostheses had been quantified with several tracers. Thrombus formation in vivo could be measured semiquantitatively in animal models and patients with indium-111, Technetium-99m labeled platelets, iodine-123, iodine-131 labeled fibrinogen, and In-111 and Tc-99m labeled antibody to the fibrinogen-receptor on the platelet- membrane, or fibrin. The early studies demonstrated that certain platelet-inhibitors, e.g. sulfinpyrazone, aspirin or aspirin- persantine increased platelet survival time with mechanical valves implanted in the baboon model and patients. Thrombus localization by imaging is possible for large thrombus on thrombogenic surface of prosthesis in the acute phase. The majority of thrombus was found in the sewing ring (Dacron) in the acute phase in both the mechanical and tissue valves. The amount of retained thrombus in both mechanical and tissue valves in our one-day study in the dog model was similar (< 1% if injected In-111 platelets = 5 billion platelets). As the fibrous ingrowth covered the sewing ring, the thrombus formation decreased significantly. Only a small amount of thrombus was found on the leaflets at one month in both the dog and calf models. 38 refs., 9 figs., 5 tabs.

  14. Dead layer and active volume determination for GERDA Phase II detectors

    Energy Technology Data Exchange (ETDEWEB)

    Lehnert, Bjoern [TU Dresden (Germany); Collaboration: GERDA-Collaboration

    2013-07-01

    The GERDA experiment investigates the neutrinoless double beta decay of {sup 76}Ge and is currently running Phase I of its physics program. Using the same isotope as the Heidelberg Moscow (HDM) experiment, GERDA aims to directly test the claim of observation by a subset of the HDM collaboration. For the update to Phase II of the experiment in 2013, the collaboration organized the production of 30 new Broad Energy Germanium (BEGe) type detectors from original 35 kg enriched material and tested their performance in the low background laboratory HADES in SCK.CEN, Belgium. With additional 20 kg of detectors, GERDA aims to probe the degenerated hierarchy scenario. One of the crucial detector parameters is the active volume (AV) fraction which directly enters into all physics analysis. This talk presents the methodology of dead layer and AV determination with different calibration sources such as {sup 241}Am, {sup 133}Ba, {sup 60}Co and {sup 228}Th and the results obtained for the new Phase II detectors. Furthermore, the AV fraction turned out to be the largest systematic uncertainty in the analysis of Phase I data which makes it imperative to reduce its uncertainty for Phase II. This talk addresses the major contributions to the AV uncertainty and gives an outlook for improvements in Phase II analysis.

  15. Reassessing Phase II Heart Failure Clinical Trials: Consensus Recommendations

    Science.gov (United States)

    Butler, Javed; Hamo, Carine E.; Udelson, James E.; O’Connor, Christopher; Sabbah, Hani N.; Metra, Marco; Shah, Sanjiv J.; Kitzman, Dalane W.; Teerlink, John; Bernstein, Harold S.; Brooks, Gabriel; Depre, Christophe; DeSouza, Mary M.; Dinh, Wilfried; Donovan, Mark; Frische-Danielson, Regina; Frost, Robert J.; Garza, Dahlia; Gohring, Udo-Michael; Hellawell, Jennifer; Hsia, Judith; Ishihara, Shiro; Kay-Mugford, Patricia; Koglin, Joerg; Kozinn, Marc; Larson, Christopher J.; Mayo, Martha; Gan, Li-Ming; Mugnier, Pierrre; Mushonga, Sekayi; Roessig, Lothar; Russo, Cesare; Salsali, Afshin; Satler, Carol; Shi, Victor; Ticho, Barry; van der Laan, Michael; Yancy, Clyde; Stockbridge, Norman; Gheorghiade, Mihai

    2017-01-01

    The increasing burden and the continued suboptimal outcomes for patients with heart failure underlines the importance of continued research to develop novel therapeutics for this disorder. This can only be accomplished with successful translation of basic science discoveries into direct human application through effective clinical trial design and execution that results in a substantially improved clinical course and outcomes. In this respect, phase II clinical trials play a pivotal role in determining which of the multitude of potential basic science discoveries should move to the large and expansive registration trials in humans. A critical examination of the phase II trials in heart failure reveals multiple shortcomings in their concept, design, execution, and interpretation. To further a dialogue regarding the challenges and potential for improvement and the role of phase II trials in patients with heart failure, the Food and Drug Administration facilitated a meeting on October 17th 2016 represented by clinicians, researchers, industry members, and regulators. This document summarizes the discussion from this meeting and provides key recommendations for future directions. PMID:28356300

  16. Controlling the cavitation phenomenon of evolution on a butterfly valve

    International Nuclear Information System (INIS)

    Baran, G; Safta, C A; Catana, I; Magheti, I; Savu, M

    2010-01-01

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  17. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Baran, G; Safta, C A [Department of Hydraulic and Hydraulic Machineries, University Politehnica of Bucharest, 313 Splaiul Independentei, Bucharest, 060042 (Romania); Catana, I [Department of Control and Computer Science, University Politehnica of Bucharest (Romania); Magheti, I; Savu, M, E-mail: baran_gheorghe@yahoo.co.u [Department of Mechanical Engineering, University Politehnica of Bucharest (Romania)

    2010-08-15

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  18. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  19. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Science.gov (United States)

    Lamana, Fernando de Azevedo; Dias, Ricardo Ribeiro; Duncan, Jose Augusto; Faria, Leandro Batisti de; Malbouisson, Luiz Marcelo Sa; Borges, Luciano de Figueiredo; Mady, Charles; Jatene, Fábio Biscegli

    2015-01-01

    To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graft-valve replacement. From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling). Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%), with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation. In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns). Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001) and lower bleeding complications (P=0.006). There was no difference for thromboembolism, endocarditis, and need of reoperation. The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  20. An in vitro experimental study of flow past aortic valve under varied pulsatile conditions

    Science.gov (United States)

    Zhang, Ruihang; Zhang, Yan

    2017-11-01

    Flow past aortic valve represents a complex fluid-structure interaction phenomenon that involves pulsatile, vortical, and turbulent conditions. The flow characteristics immediately downstream of the valve, such as the variation of pulsatile flow velocity, formation of vortices, distribution of shear stresses, are of particular interest to further elucidate the role of hemodynamics in various aortic diseases. However, the fluid dynamics of a realistic aortic valve is not fully understood. Particularly, it is unclear how the flow fields downstream of the aortic valve would change under varied pulsatile inlet boundary conditions. In this study, an in vitro experiment has been conducted to investigate the flow fields downstream of a silicone aortic valve model within a cardiovascular flow simulator. Phased-locked Particle Image Velocimetry measurements were performed to map the velocity fields and Reynolds normal and shear stresses at different phases in a cardiac cycle. Temporal variations of pressure across the valve model were measured using high frequency transducers. Results have been compared for different pulsatile inlet conditions, including varied frequencies (heart rates), magnitudes (stroke volumes), and cardiac contractile functions (shapes of waveforms).

  1. Forensic relevance of glucuronidation in phase-II-metabolism of alcohols and drugs.

    Science.gov (United States)

    Kaeferstein, Herbert

    2009-04-01

    Forensic toxicology means detecting toxic or pharmacologically active substances in body fluids and organs and the evaluation and judgement of the respective results. In the legal judgement, not only the taken in active drugs, but also their metabolites are to be included. Regarding metabolism one distinguishes phase-I- and phase-II-metabolism. In the phase-I-metabolism, active substances are converted by oxidation, reduction or hydrolysis, but influencing the polarity of more lipophilic substances often not decisively. The pharmacological activity is often preserved or even increased. In phase-II-metabolism a highly hydrophilic substance--mostly glucuronic acid--is coupled to the active substances or the respective phase-I-metabolites. This reaction step decisively increases hydrophilicity of lipophilic substances, thus enhancing renal elimination and often also abolishing pharmacologically and/or toxicologically effects. Nevertheless the interaction of different drugs and alcohols in glucuronidation and the glucuronides of phase-II-metabolism still do not play a substantial role in the forensic-toxicological analysis and interpretation of results so far. However, in vitro investigations since 1999 in our lab show that such interactions are not unlikely. For valid interpretation of complex cases in the future it may become necessary not only to quantify drugs and the phase-I-metabolites but also the phase-II-metabolites and discuss possible interactions in the metabolism.

  2. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  3. Lightweight Thermally Stable Multi-Meter Aperture Submillimeter Reflectors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the Phase II effort will be an affordable demonstrated full-scale design for a thermally stable multi-meter submillimeter reflector. The Phase I...

  4. Pressure Controlled Heat Pipe for Precise Temperature Control, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The principal Phase II objective is to refine and further develop the prototype PCHP into a useful thermal management tool. The Phase I program established the...

  5. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  6. Impact of valve failures on the safety and reliability of light water nuclear power plants

    International Nuclear Information System (INIS)

    Riddington, J.W.; Reyer, R.J.

    1980-01-01

    A study of the causes of, and solutions for, recurrent valve failures has been performed. The frequency and root causes of valve problems were identified from licensee event reports and meetings with utility, NSSS, and valve manufacturer personnel. Three generic problems (stem leakage, seat leakage, and inadequate specification) and four valve specific problems were identified. The four valve specific problems and their principal causes are: (1) BWR pilot operated safety relief valves (pilot valve leakage); (2) spring loaded safety relief valves (water solid and two-phase flow behavior); (3) PWR feedwater regulating valves (trim degradation and packing failures); and (4) air operated solenoid valves (jamming due to foreign matter in service air). The first two valve specific problems are the subject of current industry programs. Programs intended to address stem leakage, seat leakage, timely exchange of valve failure information, testing of valves, and adequate specification, selection, and maintenance of valves will be outlined

  7. Toward an Integrated Psychological Approach - Phase II

    International Development Research Centre (IDRC) Digital Library (Canada)

    Trauma, Development and Peacebuilding : Toward an Integrated Psychological Approach - Phase II. Over the past decade, the peace, conflict and development community has begun to question the value of medicalized approaches such as post-traumatic stress disorder (PTSD) in dealing with aftermath of political violence ...

  8. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    Science.gov (United States)

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  9. Diagnosis-Driven Prognosis for Decision Making, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase II, the QSI-Vanderbilt team seeks to develop a system-level diagnostics and prognostic process that incorporates a "sense and respond capability," which...

  10. Novel Instrumentation for Rocket Propulsion Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of the proposed SBIR Phase II program is to develop, deploy and deliver novel laser-based instruments that provide rapid, in situ, simultaneous...

  11. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  12. Mercury Oxidation via Catalytic Barrier Filters Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wayne Seames; Michael Mann; Darrin Muggli; Jason Hrdlicka; Carol Horabik

    2007-09-30

    In 2004, the Department of Energy National Energy Technology Laboratory awarded the University of North Dakota a Phase II University Coal Research grant to explore the feasibility of using barrier filters coated with a catalyst to oxidize elemental mercury in coal combustion flue gas streams. Oxidized mercury is substantially easier to remove than elemental mercury. If successful, this technique has the potential to substantially reduce mercury control costs for those installations that already utilize baghouse barrier filters for particulate removal. Completed in 2004, Phase I of this project successfully met its objectives of screening and assessing the possible feasibility of using catalyst coated barrier filters for the oxidation of vapor phase elemental mercury in coal combustion generated flue gas streams. Completed in September 2007, Phase II of this project successfully met its three objectives. First, an effective coating method for a catalytic barrier filter was found. Second, the effects of a simulated flue gas on the catalysts in a bench-scale reactor were determined. Finally, the performance of the best catalyst was assessed using real flue gas generated by a 19 kW research combustor firing each of three separate coal types.

  13. Compact 2-Micron Transmitter for Remote Sensing Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II effort we propose to work with NASA to extend the Phase I achievements, which focused on design and development of very compact master and...

  14. Compact, High Accuracy CO2 Monitor, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovative Research Phase II proposal seeks to develop a low cost, robust, highly precise and accurate CO2 monitoring system. This system will...

  15. Statins for progression of aortic valve stenosis and the best evidence for making decisions in health care

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    2011-01-01

    Full Text Available In the Western world, calcified aortic valve stenosis is the most common form of valvular heart disease, affecting up to 3% of adults over the age of 75 years. It is a gradually progressive disease, characterized by a long asymptomatic phase that may last for several decades, followed by a short symptomatic phase associated with severe restriction of the valve orifice. Investigations on treatments for aortic valve stenosis are still in progress. Thus, it is believed that calcification of aortic valve stenosis is similar to the process of atherosclerosis that occurs in coronary artery disease. Recent studies have suggested that cholesterol lowering through the use of statins may have a salutary effect on the progression of aortic valve stenosis

  16. Phase II beam lines at the National Synchrotron Light Source

    International Nuclear Information System (INIS)

    Thomlinson, W.

    1984-06-01

    The expansion of the National Synchrotron Light Source has been funded by the US Department of Energy. The Phase II program consists of both increased conventional facilities and six new beam lines. In this paper, an overview of the six beam lines which will be constructed during Phase II is presented. For five of the lines special radiation sources are necessary and the designs of four of the devices are complete. The relevant parameters of the insertion devices under construction and development are presented

  17. Sears Point Tidal Marsh Restoration Project: Phase II

    Science.gov (United States)

    Information about the SFBWQP Sears Point Tidal Marsh Restoration Project: Phase II, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic resources.

  18. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  19. Study of the GERDA Phase II background spectrum

    Science.gov (United States)

    Agostini, M.; Allardt, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Belyaev, S. T.; Benato, G.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Frodyma, N.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Janicskó Csáthy, J.; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Lehnert, B.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Medinaceli, E.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Palioselitis, D.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Salathe, M.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Selivanenko, O.; Shevzik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-09-01

    The Gerda experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN in Italy, searches for the neutrinoless double beta (0νββ) decay of 76Ge. Gerda Phase II is aiming to reach a sensitivity for the 0νββ half life of 1026 yr in ˜ 3 years of physics data taking with 100 kg·yr of exposure and a background index of ˜ 10-3 cts/(keV·kg·yr). After 6 months of acquisition a first data release with 10.8 kg·yr of exposure is performed, showing that the design background is achieved. In this work a study of the Phase II background spectrum, the main spectral structures and the background sources will be presented and discussed.

  20. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  1. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  2. Initial data collection efforts of CREDO. Sodium valve failures

    International Nuclear Information System (INIS)

    Bott, T.F.; Haas, P.M.

    1978-01-01

    The Centralized Reliability Data organisation (CREDO) has been established at Oak Ridge National Laboratory to define, develop, and maintain a reliability data analysis center for use in advanced reactor safety and licensing. Its primary functions are collection, reduction, evaluation, storage, retrieval, and dissemination of reliability/maintainability data. Data-collection efforts have been initiated at several test loops, at the Experimental Breeder Reactor-II and at the Fast Flux Test Facility. Top priority is being given to collection data on safety and safety-related systems, primarily for sodium-cooled reactors. Sufficient operating time has been accumulated on sodium valves at test facilities to provide quantitative estimates of reliability characteristics with a reasonable degree of confidence. Sodium-valve failures have been categorized according to seat design, size, seal type, and actuator type. Attempts have been made to establish the variation of failure rate with time and duty. Estimates of failure rates for sodium valves have been compared to those for water valves and appear to be of the same order of magnitude. (author)

  3. Status report of the Gerda Phase II startup

    Science.gov (United States)

    D'Andrea, Valerio; Gerda Collaboration

    2017-01-01

    The GERmanium Detector Array (GERDA) experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN, searches for 0νββ of 76Ge . Germanium diodes enriched to ˜ 86 % in the double beta emitter 76Ge ( enrGe are exposed being both source and detector of 0νββ decay. This process is considered a powerful probe to address still open issues in the neutrino sector of the (beyond) Standard Model of particle Physics. Since 2013, at the completion of the first experimental phase (Phase I), the GERDA setup has been upgraded to perform its next step (Phase II). The aim is to reach a sensitivity to the 0νββ decay half-life larger than 10^{26} yr in about 3 years of physics data taking, exposing a detector mass of about 35 kg of enrGe with a background index of about 10^{-3} cts/(keV . kg . yr). One of the main new implementations is the liquid argon (LAr) scintillation light read-out, to veto those events that only partially deposit their energy both in Ge and in the surrounding LAr. In this paper the GERDA Phase II expected goals, the upgraded items and few selected features from the first 2016 physics and calibration runs will be presented. The main Phase I achievements will be also reviewed.

  4. [Aortic valve preservation in Marfan syndrome. Initial experience].

    Science.gov (United States)

    Forteza, Alberto; Cortina, Jose M; Sánchez, Violeta; Centeno, Jorge; López, M Jesús; Pérez de la Sota, Enrique; Rufilanchas, Juan J

    2007-05-01

    Preservation of the aortic valve using the technique described by David has been shown to be as effective as the Bentall-De Bono procedure. It avoids both the need for long-term anticoagulation and the complications associated with mechanical prostheses. We report our initial experience using this technique in patients with Marfan syndrome. Between April 2004 and April 2006, we used the David reimplantation technique in 40 patients with an aortic root aneurysm. Eighteen patients had Marfan syndrome. Their median age was 29 years (13-55 years). Echocardiography showed that the median diameter of the aortic sinus was 53 mm (46-59 mm). In 17 patients, aortic valve preservation was possible. No patient died during hospitalization and there were no significant complications. On echocardiography at discharge, no patient had greater than grade-II aortic regurgitation. During a median follow-up period of 8 months (1-24 months), one patient died due to rupture of an abdominal aneurysm. The others are all in New York Heart Association class I. Preservation of the aortic valve by means of valve reimplantation produced excellent results. It avoided both the thromboembolic and hemorrhagic complications associated with prostheses and the need for long-term anticoagulation. If reimplanted valves continue to function adequately over the long term, this technique should become the treatment of choice for aneurysms of the ascending aorta in patients with Marfan syndrome.

  5. UltraSail Solar Sail Flight Experiment, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A team of CU Aerospace, the University of Illinois, and ManTech SRS Technologies proposes Phase II development of a 3 kg CubeSat spacecraft for initial flight test...

  6. Method for estimating steam hammer effects on swing-check valves during closure

    International Nuclear Information System (INIS)

    Uram, E.M.

    1976-01-01

    Relationships are developed for estimating the disk impact velocity resulting from a free swing closure of swing-check valves in normal flow and for pipe rupture. They derive from a phase-plane solution of the differential equation for the disk motion that accounts for the nature of the valve pressure drop variation due to steam-hammer effects during closure. For closure in normal flow, the method presented has a more correct foundation than that given in reference where a constant, average valve pressure differential based upon the steady-state pressure drop for the total piping system (which has no real relationship to the steam-hammer-induced valve pressure changes during the closure transient) is used in the valve disk motion equation

  7. Status of the GERDA Phase II upgrade

    Science.gov (United States)

    Wagner, Victoria

    2016-06-01

    The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of 76Ge. In Phase I of the experiment a background index of 10-2 cts/(keV.kg.yr) was reached. A lower limit on the half-life of the 0νββ decay of 76Ge was set to 2.1.1025 yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 1026 yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from 214Bi and 208Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10-3 cts/(keV.kg.yr) which is the design goal for GERDA Phase II.

  8. [Extracorporeal ventriculoatrial shunt with the use of one-way ball valve].

    Science.gov (United States)

    Kubo, Shigeki; Takimoto, Hiroshi; Hosoi, Kazuki; Toyota, Shingo; Takakura, Shuji; Hayashi, Yasuhiro; Ueno, Masato; Morisako, Toshitaka; Karasawa, Jun; Ninaga, Hideo; Yoshimine, Toshiki

    2002-04-01

    We developed a simple system of an "extracorporeal" ventriculoatrial (VA) shunt using a one-way ball valve (Acty valve II, Kaneka Medix) to release the patient from postoperative constraint during the ventricular drainage. The system is constructed in such a way that the ventricular drainage tube is connected to the central venous catheter via a one-way valve. The CSF is regulated by using the valve and is diverted into the systemic circulation as in the conventional ventriculoatrial shunt. After 2 or 3 weeks of CSF diversion through the extracorporeal VA shunt, a ventriculoperitoneal shunt is placed if hydrocephalus is apparent by temporary occlusion of the system. We applied this system to 4 patients with hydrocephalus, and we found it useful and free from adverse effects. The patient was freed from physical constraint involved in conventional ventricular drainage and an effective program of early rehabilitation was able to be started.

  9. Solid-phase extraction of Mn(II), Co(II), Ni(II), Cu(II), Cd(II) and Pb(II) ions from environmental samples by flame atomic absorption spectrometry (FAAS)

    Energy Technology Data Exchange (ETDEWEB)

    Duran, Celal [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Gundogdu, Ali [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Bulut, Volkan Numan [Department of Chemistry, Giresun Faculty of Art and Science, Karadeniz Technical University, 28049 Giresun (Turkey); Soylak, Mustafa [Department of Chemistry, Faculty of Art and Science, Erciyes University, 38039 Kayseri (Turkey)]. E-mail: soylak@erciyes.edu.tr; Elci, Latif [Department of Chemistry, Faculty of Art and Science, Pamukkale University, 20020 Denizli (Turkey); Sentuerk, Hasan Basri [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey); Tuefekci, Mehmet [Department of Chemistry, Faculty of Art and Science, Karadeniz Technical University, 61080 Trabzon (Turkey)

    2007-07-19

    A new method using a column packed with Amberlite XAD-2010 resin as a solid-phase extractant has been developed for the multi-element preconcentration of Mn(II), Co(II), Ni(II), Cu(II), Cd(II), and Pb(II) ions based on their complex formation with the sodium diethyldithiocarbamate (Na-DDTC) prior to flame atomic absorption spectrometric (FAAS) determinations. Metal complexes sorbed on the resin were eluted by 1 mol L{sup -1} HNO{sub 3} in acetone. Effects of the analytical conditions over the preconcentration yields of the metal ions, such as pH, quantity of Na-DDTC, eluent type, sample volume and flow rate, foreign ions etc. have been investigated. The limits of detection (LOD) of the analytes were found in the range 0.08-0.26 {mu}g L{sup -1}. The method was validated by analyzing three certified reference materials. The method has been applied for the determination of trace elements in some environmental samples.

  10. The Ross II procedure: pulmonary autograft in the mitral position.

    Science.gov (United States)

    Athanasiou, Thanos; Cherian, Ashok; Ross, Donald

    2004-10-01

    The surgical management of mitral valve disease in women of childbearing age, young patients, and children with congenital mitral valve defects is made difficult by the prospect of lifelong anticoagulation. We suggest the use of a pulmonary autograft in the mitral position (Ross II procedure) as an alternative surgical technique. We present a review of the literature, historical perspectives, indications, selection criteria, and surgical technique for the Ross II procedure. Our literature search identified 14 studies that reported results from the Ross II operation. Performed in 103 patients, the overall in-hospital mortality was 7 (6.7%), with a late mortality of 10 (9%). Although further research is needed, current evidence suggests the Ross II operation is a valuable alternative in low-risk young patients where valve durability and the complication rate from other procedures is unsatisfactory and anticoagulation not ideal.

  11. Developing an optimal valve closing rule curve for real-time pressure control in pipes

    Energy Technology Data Exchange (ETDEWEB)

    Bazarganlari, Mohammad Reza; Afshar, Hossein [Islamic Azad University, Tehran (Iran, Islamic Republic of); Kerachian, Reza [University of Tehran, Tehran (Iran, Islamic Republic of); Bashiazghadi, Seyyed Nasser [Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2013-01-15

    Sudden valve closure in pipeline systems can cause high pressures that may lead to serious damages. Using an optimal valve closing rule can play an important role in managing extreme pressures in sudden valve closure. In this paper, an optimal closing rule curve is developed using a multi-objective optimization model and Bayesian networks (BNs) for controlling water pressure in valve closure instead of traditional step functions or single linear functions. The method of characteristics is used to simulate transient flow caused by valve closure. Non-dominated sorting genetic algorithms-II is also used to develop a Pareto front among three objectives related to maximum and minimum water pressures, and the amount of water passes through the valve during the valve-closing process. Simulation and optimization processes are usually time-consuming, thus results of the optimization model are used for training the BN. The trained BN is capable of determining optimal real-time closing rules without running costly simulation and optimization models. To demonstrate its efficiency, the proposed methodology is applied to a reservoir-pipe-valve system and the optimal closing rule curve is calculated for the valve. The results of the linear and BN-based valve closure rules show that the latter can significantly reduce the range of variations in water hammer pressures.

  12. Compressed gas domestic aerosol valve design using high viscous product

    Directory of Open Access Journals (Sweden)

    A Nourian

    2016-10-01

    Full Text Available Most of the current universal consumer aerosol products using high viscous product such as cooking oil, antiperspirants, hair removal cream are primarily used LPG (Liquefied Petroleum Gas propellant which is unfriendly environmental. The advantages of the new innovative technology described in this paper are: i. No butane or other liquefied hydrocarbon gas is used as a propellant and it replaced with Compressed air, nitrogen or other safe gas propellant. ii. Customer acceptable spray quality and consistency during can lifetime iii. Conventional cans and filling technology There is only a feasible energy source which is inert gas (i.e. compressed air to replace VOCs (Volatile Organic Compounds and greenhouse gases, which must be avoided, to improve atomisation by generating gas bubbles and turbulence inside the atomiser insert and the actuator. This research concentrates on using "bubbly flow" in the valve stem, with injection of compressed gas into the passing flow, thus also generating turbulence. The new valve designed in this investigation using inert gases has advantageous over conventional valve with butane propellant using high viscous product (> 400 Cp because, when the valving arrangement is fully open, there are negligible energy losses as fluid passes through the valve from the interior of the container to the actuator insert. The use of valving arrangement thus permits all pressure drops to be controlled, resulting in improved control of atomising efficiency and flow rate, whereas in conventional valves a significant pressure drops occurs through the valve which has a complex effect on the corresponding spray.

  13. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  14. Surgery of the aortic root: should we go for the valve-sparing root reconstruction or the composite graft-valve replacement is still the first choice of treatment for these patients?

    Directory of Open Access Journals (Sweden)

    Fernando de Azevedo Lamana

    2015-09-01

    Full Text Available AbstractObjective:To compare the results of the root reconstruction with the aortic valve-sparing operation versus composite graftvalve replacement.Methods:From January 2002 to October 2013, 324 patients underwent aortic root reconstruction. They were 263 composite graft-valve replacement and 61 aortic valve-sparing operation (43 reimplantation and 18 remodeling. Twenty-six percent of the patients were NYHA functional class III and IV; 9.6% had Marfan syndrome, and 12% had bicuspid aortic valve. There was a predominance of aneurysms over dissections (81% vs. 19%, with 7% being acute dissections. The complete follow-up of 100% of the patients was performed with median follow-up time of 902 days for patients undergoing composite graft-valve replacement and 1492 for those undergoing aortic valve-sparing operation.Results:In-hospital mortality was 6.7% and 4.9%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. During the late follow-up period, there was 0% moderate and 15.4% severe aortic regurgitation, and NYHA functional class I and II were 89.4% and 94%, respectively for composite graft-valve replacement and aortic valve-sparing operation (ns. Root reconstruction with aortic valve-sparing operation showed lower late mortality (P=0.001 and lower bleeding complications (P=0.006. There was no difference for thromboembolism, endocarditis, and need of reoperation.Conclusion:The aortic root reconstruction with preservation of the valve should be the operation being performed for presenting lower late mortality and survival free of bleeding events.

  15. The effect of valve strategy on in-cylinder flow and combustion

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, F

    1997-01-01

    This paper examines the effects of different valve strategies and their effect on in-cylinder flow and combustion. A conventional four valve per cylinder otto engine was modified to enable optical access. The flow measurements were made with a two-component laser Doppler velocimetry system. The combustion was monitored by running pressure data from a pressure transducer through a one-zone heat release model. The results show that when the valves operate normally a barrel flow is present and when one valve is closed a swirling flow occurs. No increase in turbulence was found with later phasing, except in the case of very late inlet valve opening and port deactivation. This resulted in a jet with high turbulence, making the combustion fast and stable, even with a very lean mixture ({lambda}=1.8). 6 refs, 44 figs, 4 tabs

  16. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  17. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  18. Long-term results after aortic valve-sparing operation (David I).

    Science.gov (United States)

    Shrestha, Malakh; Baraki, Hassina; Maeding, Ilona; Fitzner, Sebastian; Sarikouch, Samir; Khaladj, Nawid; Hagl, Christian; Haverich, Axel

    2012-01-01

    Aortic valve-sparing David procedure has gained broad acceptance. However, few long-term results have been published. We present our results. More than 450 David procedures have been performed in our institution so far. Of these, 126 patients were operated between July 1993 and December 2000. Median age was 57 (8-83) years and 46 (36.5%) were female. As many as 26 (20.6%) had Marfan syndrome, 21 (16.7%) had acute aortic dissection type A (AADA) and 67 (53.2%) had additional procedures. There were six (4.8%) deaths in 30 post-operative period (POD), four of whom had AADA. In the follow-up, there were 32 (25.4%) late deaths, 11 (34.4%) of these were caused by cardiac or underlying disease or op-related. As many as 15 (11.9%) patients were re-operated; six (40%) were Marfan patients and two (13.3%) had early endocarditis. Follow-up echocardiography of 76 (60.3%) event-free patients showed valve insufficiency (AI)≤AI I° in 68 (89.5%) and grade II in 7 (9.2%) patients. Leaflet degeneration due to proposed leaflet contact with the straight Dacron graft was not observed. A total of 36 (47.4%) patients were in New York Heart Association (NYHA) class I, 33 (43.4%) in NYHA II, and five (6.6%) were in class III. During the entire follow-up of 790 patient-years, there was no stroke or major bleeding. Survival at 1, 5 and 10 years was 93%, 85% and 70%, respectively. Freedom from valve replacement at 1, 5 and 10 years was 96%, 91% and 87%, respectively. Regardless of the underlying pathology, valve-sparing David I procedure has acceptable long-term results. Valve-related complications such as stroke or major bleeding is exceedingly low.

  19. Development of a micro-mechanical valve in a novel glaucoma implant.

    Science.gov (United States)

    Siewert, Stefan; Schultze, Christine; Schmidt, Wolfram; Hinze, Ulf; Chichkov, Boris; Wree, Andreas; Sternberg, Katrin; Allemann, Reto; Guthoff, Rudolf; Schmitz, Klaus-Peter

    2012-10-01

    This paper describes methods for design, manufacturing and characterization of a micro-mechanical valve for a novel glaucoma implant. The implant is designed to drain aqueous humour from the anterior chamber of the eye into the suprachoroidal space in case of an elevated intraocular pressure (IOP). In contrast to any existing glaucoma drainage device (GDD), the valve mechanism is located in the anterior chamber and there, surrounded by aqueous humour, immune to fibrosis induced failure. For the prevention of hypotony the micro-mechanical valve is designed to open if the physiological pressure difference between the anterior chamber and the suprachoroidal space in the range of 0.8 mmHg to 3.7 mmHg is exceeded. In particular the work includes: (i) manufacturing and morphological characterization of polymer tubing, (ii) mechanical material testing as basis for (iii) the design of micro-mechanical valves using finite element analysis (FEA), (iv) manufacturing of microstent prototypes including micro-mechanical valves by femtosecond laser micromachining and (v) the experimental fluid-mechanical characterization of the manufactured microstent prototypes with regard to valve opening pressure. The considered materials polyurethane (PUR) and silicone (SIL) exhibit low elastic modulus and high extensibility. The unique valve design enables a low opening pressure of micro-mechanical valves. An ideal valve design for PUR and SIL with an experimentally determined opening pressure of 2 mmHg and 3.7 mmHg is identified. The presented valve approach is suitable for the inhibition of hypotony as a major limitation of today's GDD and will potentially improve the minimally invasive treatment of glaucoma.

  20. Ultraflat Tip-Tilt-Piston MEMS Deformable Mirror, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This proposal describes a Phase II SBIR project to develop high-resolution, ultraflat micromirror array devices using advanced silicon surface micromachining...

  1. Steam generator tube integrity program: Phase II, Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Bickford, R.L.; Clark, R.A.; Morris, C.J.; Simonen, F.A.; Wheeler, K.R.

    1988-08-01

    The Steam Generator Tube Integrity Program (SGTIP) was a three phase program conducted for the US Nuclear Regulatory Commission (NRC) by Pacific Northwest Laboratory (PNL). The first phase involved burst and collapse testing of typical steam generator tubing with machined defects. The second phase of the SGTIP continued the integrity testing work of Phase I, but tube specimens were degraded by chemical means rather than machining methods. The third phase of the program used a removed-from-service steam generator as a test bed for investigating the reliability and effectiveness of in-service nondestructive eddy-current inspection methods and as a source of service degraded tubes for validating the Phase I and Phase II data on tube integrity. This report describes the results of Phase II of the SGTIP. The object of this effort included burst and collapse testing of chemically defected pressurized water reactor (PWR) steam generator tubing to validate empirical equations of remaining tube integrity developed during Phase I. Three types of defect geometries were investigated: stress corrosion cracking (SCC), uniform thinning and elliptical wastage. In addition, a review of the publicly available leak rate data for steam generator tubes with axial and circumferential SCC and a comparison with an analytical leak rate model is presented. Lastly, nondestructive eddy-current (EC) measurements to determine accuracy of defect depth sizing using conventional and alternate standards is described. To supplement the laboratory EC data and obtain an estimate of EC capability to detect and size SCC, a mini-round robin test utilizing several firms that routinely perform in-service inspections was conducted.

  2. Steam generator tube integrity program: Phase II, Final report

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Bickford, R.L.; Clark, R.A.; Morris, C.J.; Simonen, F.A.; Wheeler, K.R.

    1988-08-01

    The Steam Generator Tube Integrity Program (SGTIP) was a three phase program conducted for the US Nuclear Regulatory Commission (NRC) by Pacific Northwest Laboratory (PNL). The first phase involved burst and collapse testing of typical steam generator tubing with machined defects. The second phase of the SGTIP continued the integrity testing work of Phase I, but tube specimens were degraded by chemical means rather than machining methods. The third phase of the program used a removed-from-service steam generator as a test bed for investigating the reliability and effectiveness of in-service nondestructive eddy-current inspection methods and as a source of service degraded tubes for validating the Phase I and Phase II data on tube integrity. This report describes the results of Phase II of the SGTIP. The object of this effort included burst and collapse testing of chemically defected pressurized water reactor (PWR) steam generator tubing to validate empirical equations of remaining tube integrity developed during Phase I. Three types of defect geometries were investigated: stress corrosion cracking (SCC), uniform thinning and elliptical wastage. In addition, a review of the publicly available leak rate data for steam generator tubes with axial and circumferential SCC and a comparison with an analytical leak rate model is presented. Lastly, nondestructive eddy-current (EC) measurements to determine accuracy of defect depth sizing using conventional and alternate standards is described. To supplement the laboratory EC data and obtain an estimate of EC capability to detect and size SCC, a mini-round robin test utilizing several firms that routinely perform in-service inspections was conducted

  3. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  4. Reconfigurable L-band Radar Transceiver using Digital Signal Synthesis, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II proposal, builds upon the extensive research and digital radar design that has been successfully completed during the Phase I contract. Key innovations...

  5. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  6. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  7. Single Photon Sensitive HgCdTe Avalanche Photodiode Detector (APD), Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Leveraging Phase I SBIR successes, in Phase II, a single photon sensitive LIDAR receiver will be fabricated and delivered to NASA. In Phase I, high-gain,...

  8. Testing of cobalt-free alloys for valve applications using a special test loop

    International Nuclear Information System (INIS)

    Benhamou, C.

    1992-01-01

    Considering that use of cobalt alloys should be avoided as far as possible in PWR components, a programme aimed at establishing the performance of cobalt-free alloys has been performed for valve applications, where cobalt alloys are mainly used. Referring to past work, two types of cobalt-free alloys were selected: Ni-Cr-B-Si and Ni-Cr-Fe alloys. Cobalt-free valves' behaviour has been evaluated comparatively with cobalt valves by implementation of a programme in a special PWR test loop. At the issue of the loop test programme, which included endurance, thermal shock and erosion tests, cobalt-free alloys candidate to replace cobalt alloys are proposed in relation with valve type (globe valve and swing check valve). The following was established: (i) Colmonoy 4-26 (Ni-Cr-B-Si alloy) and Cenium Z20 (Ni-Cr-Fe alloy) deposited by plasma arc process were found suitable for use in 3inch swing check valves; (ii) for integral parts acting as guide rings, Nitronic 60 and Cesium Z20/698 were tested successfully; (iii) for small-bore components such as 2inch globe valves, no solution can yet be proposed; introduction of cobalt-free alloys is dependent on the development of automatic advanced arc surfacing techniques applied to small-bore components

  9. Status report of the Gerda Phase II startup

    International Nuclear Information System (INIS)

    D’Andrea, Valerio

    2017-01-01

    The GERmanium Detector Array (Gerda) experiment, located at the Laboratori Nazionali del Gran Sasso (LNGS) of INFN, searches for 0νββ of "7"6Ge. Germanium diodes enriched to ∼ 86 % in the double beta emitter "7"6Ge ("e"n"rGe) are exposed being both source and detector of 0νββ decay. This process is considered a powerful probe to address still open issues in the neutrino sector of the (beyond) Standard Model of particle Physics. Since 2013, at the completion of the first experimental phase (Phase I), the Gerda setup has been upgraded to perform its next step (Phase II). The aim is to reach a sensitivity to the 0νββ decay half life larger than 10"2"6 yr in about 3 years of physics data taking, exposing a detector mass of about 35 kg of "e"n"rGe with a background index of about 10"−"3cts/(keV·kg·yr). One of the main new implementations is the liquid argon (LAr) scintillation light read-out, to veto those events that only partially deposit their energy both in Ge and in the surrounding LAr. In this paper the Gerda Phase II expected goals, the upgraded items and few selected features from the first 2016 physics and calibration runs will be presented. The main Phase I achievements will be also reviewed.

  10. LHC Experiments Phase II - TDRs Approval Process

    CERN Document Server

    Forti, F

    2017-01-01

    The overall review process and steps of Phase II were described in CERN-LHCC-2015-077. As experiments submit detailed technical design reports (TDRs), the LHCC and UCG work in close connection to ensure a timely review of the scientific and technical feasibility as well as of the budget and schedule of the upgrade programme.

  11. Early Outcomes of Sutureless Aortic Valves

    Directory of Open Access Journals (Sweden)

    Muhammet Onur Hanedan

    2016-06-01

    Full Text Available Background: In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Methods: Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA valves were used. Results: The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7% were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69% died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. Conclusion: In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  12. Early Outcomes of Sutureless Aortic Valves.

    Science.gov (United States)

    Hanedan, Muhammet Onur; Mataracı, İlker; Yürük, Mehmet Ali; Özer, Tanıl; Sayar, Ufuk; Arslan, Ali Kemal; Ziyrek, Uğur; Yücel, Murat

    2016-06-01

    In elderly high-risk surgical patients, sutureless aortic valve replacement (AVR) should be an alternative to standard AVR. The potential advantages of sutureless aortic prostheses include reducing cross-clamping and cardiopulmonary bypass (CPB) time and facilitating minimally invasive surgery and complex cardiac interventions, while maintaining satisfactory hemodynamic outcomes and low rates of paravalvular leakage. The current study reports our single-center experience regarding the early outcomes of sutureless aortic valve implantation. Between October 2012 and June 2015, 65 patients scheduled for surgical valve replacement with symptomatic aortic valve disease and New York Heart Association function of class II or higher were included to this study. Perceval S (Sorin Biomedica Cardio Srl, Sallugia, Italy) and Edwards Intuity (Edwards Lifesciences, Irvine, CA, USA) valves were used. The mean age of the patients was 71.15±8.60 years. Forty-four patients (67.7%) were female. The average preoperative left ventricular ejection fraction was 56.9±9.93. The CPB time was 96.51±41.27 minutes and the cross-clamping time was 60.85±27.08 minutes. The intubation time was 8.95±4.19 hours, and the intensive care unit and hospital stays were 2.89±1.42 days and 7.86±1.42 days, respectively. The mean quantity of drainage from chest tubes was 407.69±149.28 mL. The hospital mortality rate was 3.1%. A total of five patients (7.69%) died during follow-up. The mean follow-up time was 687.24±24.76 days. The one-year survival rate was over 90%. In the last few years, several models of valvular sutureless bioprostheses have been developed. The present study evaluating the single-center early outcomes of sutureless aortic valve implantation presents the results of an innovative surgical technique, finding that it resulted in appropriate hemodynamic conditions with acceptable ischemic time.

  13. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  14. Shape Memory Alloy-Based Periodic Cellular Structures, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This SBIR Phase II effort will continue to develop and demonstrate an innovative shape memory alloy (SMA) periodic cellular structural technology. Periodic cellular...

  15. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  16. Status of the GERDA Phase II upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria [Max-Planck-Insitut für Kernphysik, Heidelberg (Germany)

    2016-06-21

    The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of {sup 76}Ge. In Phase I of the experiment a background index of 10{sup −2} cts/(keV·kg·yr) was reached. A lower limit on the half-life of the 0νββ decay of {sup 76}Ge was set to 2.1·10{sup 25} yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 10{sup 26} yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from {sup 214}Bi and {sup 208}Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10{sup −3} cts/(keV·kg·yr) which is the design goal for GERDA Phase II.

  17. Status of the GERDA Phase II upgrade

    International Nuclear Information System (INIS)

    Wagner, Victoria

    2016-01-01

    The GERDA experiment is designed to search for neutrinoless double beta (0νββ) decay of "7"6Ge. In Phase I of the experiment a background index of 10"−"2 cts/(keV·kg·yr) was reached. A lower limit on the half-life of the 0νββ decay of "7"6Ge was set to 2.1·10"2"5 yr (at 90% C.L.). The aim of Phase II is to reach a sensitivity of the half-life of about 10"2"6 yr. To increase the exposure thirty new Broad Energy Germanium (BEGe) detectors have been produced. These detectors are distinct for their improved energy resolution and enhanced pulse shape discrimination of signal from background events. Further background reduction will be reached by a light instrumentation to read out argon scintillation light. In April 2015 the light instrumentation together with eight BEGe detectors has been successfully deployed in the GERDA cryostat. In a commissioning run it was shown that two of the major background components, external γ-rays from "2"1"4Bi and "2"0"8Tl decays, were suppressed up to two orders of magnitude. We are confident to reach a background index of 10"−"3 cts/(keV·kg·yr) which is the design goal for GERDA Phase II.

  18. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  19. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  20. HDR-investigations of check valve closure and resultant water hammer effects

    International Nuclear Information System (INIS)

    Scholl, K.D.

    1983-01-01

    The presented investigations are based on the Loss of Coolant Accident (LOCA). They concentrate on the first blowdown phase after pipe break of a feedwater line. The effect of such a break is moderated by quick closing check valves, by which the loss of coolant water is reduced and optimal post accident conditions are obtained. Unfortunately the closure of the valve can cause high pressure peaks (water hammer effects) in the feedwater system which potentially could produce safety relevant secondary damage. The system loading by these effects has been analysed. The HDR-Investigation-results led to an improvement of the feedwater system safety by verifying damping measures of quick closing check valves. Pressure peaks obtained with undamped valves in the range of 300 bars, are reduced to zero or a few bars above the normal operation pressure in feedwater systems. For the analytical simulation of valve closure the following dominant acting forces are identified: the blowdown flow resistance of the valve cone and the damping pistong force. The analytical description and quantification of the forces depends on blowdown flow and valve friction parameters. These have been evaluated and are presented for practical use. (orig.)

  1. Numerical investigation on cavitation in pressure relief valve for coal liquefaction

    International Nuclear Information System (INIS)

    Ou, G F; Li, W Z; Xiao, D H; Zheng, Z J; Dou, H S; Wang, C

    2015-01-01

    The pressure relief valve for regulating the level of the high-pressure separator works under a pressure difference up to 15 MPa in the temperature of 415 °C. Severe cavitation erosion and particle impact lead to the valve disc's mass loss. In this paper, three-dimensional turbulent cavitating flows in the pressure relief valve are numerically simulated to reveal the mechanism of mass loss at valve disc. The RNG k-ε turbulence model and the mixture model with a mass transfer for cavitation are employed to simulate the cavitating flow in the pressure relief valve. The result shows that there is phase change in the pressure relief process and cavitation bubbles would be transported by high-velocity backflow to the head of valve disc. For the local pressure higher than the saturated vapor pressure, the bubbles collapse at the head of disc and cavitation erosion is formed at the head of the disc. By comparing the cases of opening of 40%, 50%, and 60%, backflow velocity and cavitation region in front of the disc decrease with the opening increase. Therefore, during the actual operation, the pressure relief valve should be kept to a relatively large opening

  2. Instrument for Airborne Measurement of Carbonyl Sulfide, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II SBIR program, Southwest Sciences will continue the development of small, low power instrumentation for real-time direct measurement of carbonyl...

  3. High Radiation Resistance Inverted Metamorphic Solar Cell, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The innovation in this SBIR Phase II project is the development of a unique triple junction inverted metamorphic technology (IMM), which will enable the...

  4. Results of the motor-operated valve engineering and testing program

    International Nuclear Information System (INIS)

    Black, B.R.

    1994-01-01

    The Texas Utilities Electric Company (TU Electric) motor-operated valve (MOV) program for implementing the recommendations of Generic Letter 89-10 has typically included the following: refurbishing each actuator, verifying each actuator's as-built configuration, testing each actuator's motor on a dynamometer, testing each actuator's torque spring pack (which is used to control the torque developed), testing each fully refurbished and reassembled actuator on a torque test stand, and testing as many MOVs as practicable both without fluid flow through the valve and with the maximum test conditions reasonably achievable (static and differential pressures (DP) conditions, respectively). Test data are acquired at 1,000 samples per second for stem thrust, stem torque, stem position, actuator compensator spring pack deflection, actuator torque spring pack deflection, motor current, motor voltage, motor three-phase power, valve upstream pressure, and valve downstream pressure, wherever practicable

  5. Assessment of nonintrusive methods for monitoring the operational readiness of solenoid-operated valves

    International Nuclear Information System (INIS)

    Kryter, R.C.

    1988-01-01

    Solenoid-operated valves (SOVs) are being studied at Oak Ridge National Laboratory as part of the USNRC Nuclear Plant Aging Research (NPAR) Program. The primary objective of the study is to identify and recommend methods for inspection, surveillance, and maintenance of SOVs that can ensure their operational readiness-- that is, their ability to perform required safety functions under all anticipated operating conditions. An earlier (Phase I) study described SOV failure modes and causes and identified measurable parameters that might be used to monitor the various degradations that lead to functional failure. The present (Phase II) study focuses on devising and then demonstrating the effectiveness of techniques and/or equipment with which to measure the previously identified performance parameters and thus detect and trend the progress of any degradation. Several nonintrusive techniques are currently under investigation. Recent experimental results which demonstrate the feasibility and practicality of the techniques being studied are presented. 4 refs., 6 figs., 2 tabs

  6. Recent Advances in Understanding of Kinetic Interplay Between Phase II Metabolism and Efflux Transport.

    Science.gov (United States)

    Wang, Shuai; Xing, Huijie; Zhao, Mengjing; Lu, Danyi; Li, Zhijie; Dong, Dong; Wu, Baojian

    2016-01-01

    Mechanistic understanding of the metabolism-transport interplay assumes great importance in pharmaceutical fields because the knowledge can help to interpret drug/xenobiotic metabolism and disposition studies as well as the drug-drug interactions in vivo. About 10 years ago, it started to recognize that cellular phase II metabolism is strongly influenced by the excretion (efflux transport) of generated metabolites, a kinetic phenomenon termed "phase II metabolism-transport interplay". This interplay is believed to have significant effects on the pharmacokinetics (bioavailability) of drugs/chemicals undergoing phase II metabolism. In this article, we review the studies investigating the phase II metabolism-transport interplay using cell models, perfused rat intestine, and intact rats. The potential confounding factors in exploring such interplay is also summarized. Moreover, the mechanism underlying the phase II metabolism-transport interplay is discussed. Various studies with engineered cells and rodents have demonstrated that there is an interaction (interplay) between phase II enzymes and efflux transporters. This type of interplay mainly refers to the dependence of phase II (conjugative) metabolism on the activities of efflux transporters. In general, inhibiting efflux transporters or decreasing their expression causes the reductions in metabolite excretion, apparent excretion clearance (CLapp) and total metabolism (fmet), as well as an increase in the intracellular level of metabolite (Ci). The deconjugation mediated by hydrolase (acting as a "bridge") is essential for the interplay to play out based on pharmacokinetic modeling/simulations, cell and animal studies. The hydrolases bridge the two processes (i.e., metabolite formation and excretion) and enable the interplay thereof (a bridging effect). Without the bridge, metabolite formation is independent on its downstream process excretion, thus impact of metabolite excretion on its formation is impossible

  7. Multi-Channel Tunable Source for Atomic Sensors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase II SBIR will seek to develop a prototype laser source suitable for atomic interferometry from compact, robust, integrated components. AdvR's design is...

  8. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  9. The NEA Forum on Stakeholder Confidence - Phase I Lessons and Phase II Activities

    Energy Technology Data Exchange (ETDEWEB)

    Brown, Peter [Natural Resources Canada, Ottawa (Canada). Uranium and Radioactive Waste Div.; Pescatore, Claudio [Nuclear Energy Agency, Paris (France)

    2006-09-15

    The Forum on Stakeholder Confidence (FSC) was created under a mandate from the OECD Nuclear Energy Agency (NEA) Radioactive Waste Management Committee (RWMC) to facilitate the sharing of international experience in addressing the societal dimension of radioactive waste management. It explores means of ensuring an effective dialogue with the public, and considers ways to strengthen confidence in decision-making processes. The Forum was launched in August 2000 and completed its first phase in 00 . Major findings and principles for action were published under the title of 'Learning and Adapting to Societal Requirements'. Activities of the FSC were also reported at Valdor 2003. In the second mandate of the FSC, there is continued use of a variety of tools and formats to allow dialogue among stakeholders in an atmosphere of mutual trust: national workshops and community visits, topical sessions, and desk and interview studies. In Phase II, the FSC is exploring: the link between research, development and demonstration and stakeholder confidence; cultural and organisational changes in RWM institutions; the role of media relations and outreach opportunities; tools and processes to help society prepare and manage decisions through stakeholder involvement; and increasing the value of waste management facilities to local communities. Workshops have been held in Germany and Spain. A large set of publications makes both Phase I and Phase II findings widely available.

  10. The NEA Forum on Stakeholder Confidence - Phase I Lessons and Phase II Activities

    International Nuclear Information System (INIS)

    Brown, Peter

    2006-01-01

    The Forum on Stakeholder Confidence (FSC) was created under a mandate from the OECD Nuclear Energy Agency (NEA) Radioactive Waste Management Committee (RWMC) to facilitate the sharing of international experience in addressing the societal dimension of radioactive waste management. It explores means of ensuring an effective dialogue with the public, and considers ways to strengthen confidence in decision-making processes. The Forum was launched in August 2000 and completed its first phase in 00 . Major findings and principles for action were published under the title of 'Learning and Adapting to Societal Requirements'. Activities of the FSC were also reported at Valdor 2003. In the second mandate of the FSC, there is continued use of a variety of tools and formats to allow dialogue among stakeholders in an atmosphere of mutual trust: national workshops and community visits, topical sessions, and desk and interview studies. In Phase II, the FSC is exploring: the link between research, development and demonstration and stakeholder confidence; cultural and organisational changes in RWM institutions; the role of media relations and outreach opportunities; tools and processes to help society prepare and manage decisions through stakeholder involvement; and increasing the value of waste management facilities to local communities. Workshops have been held in Germany and Spain. A large set of publications makes both Phase I and Phase II findings widely available

  11. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  12. Adaptive Holography in Liquid Crystal Light-Valves

    Directory of Open Access Journals (Sweden)

    Jean-Pierre Huignard

    2012-08-01

    Full Text Available By performing two-wave mixing experiments in a liquid crystal light-valve, optical beam amplification is obtained as a strongly resonant process to which a narrow frequency bandwidth is associated. This property is exploited to realize adaptive holographic interferometric systems able to efficiently detect displacements as small as fraction of picometers. Pressure radiation induced deformations of a reflecting membrane are measured with the same type of system. Then, when used with complex wavefronts, like speckle fields, the LCLV-based interferometer allows to detect extremely small phase modulations. The examples shown demonstrate the potentialities of the light-valve for dynamic holography applications.

  13. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  14. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  15. The new Toyota variable valve timing and lift system

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, K.; Fuwa, N.; Yoshihara, Y. [Toyota Motor Corporation (Japan); Hori, K. [Toyota Boshoku Corporation (Japan)

    2007-07-01

    A continuously variable valve timing (duration and phase) and lift system was developed. This system was applied to the valvetrain of a new 2.0L L4 engine (3ZRFAE) for the Japanese market. The system has rocker arms, which allow continuously variable timing and lift, situated between a conventional roller-rocker arm and the camshaft, an electromotor actuator to drive it and a phase mechanism for intake and exhaust camshafts (Dual VVT-i). The rocking center of the rocker arm is stationary, and the axial linear motion of a helical spline changes the initial phase of the rocker arm which varies the timing and lift. The linear motion mechanism uses an original planetary roller screw and is driven by a brushless motor with a built-in electric control unit. Since the rocking center and the linear motion helical spline center coincide, a compact cylinder head design was possible, and the cylinder head is a common design with a conventional engine. Since the ECU controls intake valve duration and timing, a fuel economy gain of maximum 10% (depending on driving condition) is obtained by reducing light to medium load pumping losses. Also intake efficiency was maximized throughout the speed range, resulting in a power gain of 10%. Further, HC emissions were reduced due to increased air speed at low valve lift. (orig.)

  16. Recession-Tolerant Sensors for Thermal Protection Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The Phase II project will develop a suite of diagnostic sensors using Direct Write technology to measure temperature, surface recession depth, and heat flux of an...

  17. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  18. Acute Right Coronary Ostial Stenosis during Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Sarwar Umran

    2012-01-01

    Full Text Available We report a rare case of acute right coronary artery stenosis developing in a patient undergoing aortic valve replacement. We present a case report with a brief overview of the literature relating to coronary artery occlusion associated with cardiac valve surgery - the theories and treatments are discussed. A 85 year-old female was admitted under the care of the cardiothoracic team with signs and symptoms of heart failure. Investigations, including cardiac echocardiography and coronary angiography, indicated a critical aortic valve stenosis. Intraoperative right ventricular failure ensued post aortic valve replacement. Subsequent investigations revealed an acute occlusion of the proximal right coronary artery with resultant absence of distal flow supplying the right ventricle. An immediate right coronary artery bypass procedure was performed with resolution of the right ventricular failure. Subsequent weaning off cardiopulmonary bypass was uneventful and the patient continued to make excellent recovery in the postoperative phase. To our knowledge this is one of the few documented cases of intraoperative acute coronary artery occlusion developing during valve surgery. However, surgeons should be aware of the potential for acute occlusion so that early recognition and rapid intervention can be instituted.

  19. Development of ceramics based fuel, Phase II; Razvoj goriva na bazi keramike, II faza

    Energy Technology Data Exchange (ETDEWEB)

    Ristic, M M [Institute of Nuclear Sciences Vinca, Laboratorija za reaktorske materijale, Beograd (Serbia and Montenegro)

    1962-12-15

    Phase II of this task covers the following: testing the changes of UO{sub 2} properties during sintering; interpretation of results obtained from the analysis of the sintering process kinetics; fabrication of UO{sub 2} samples with cladding by vibrational compacting.

  20. Ground Processing Optimization Using Artificial Intelligence Techniques, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The ultimate goal is the automation of a large amount of KSC's planning, scheduling, and execution decision making. Phase II will result in a complete full-scale...

  1. Lightweight Metal RubberTM Sensors and Interconnects, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objective of this NASA Phase II program is to develop and increase the Technology Readiness Level of multifunctional Metal RubberTM (MRTM) materials that can be...

  2. Long-term results after aortic valve-sparing operation (David I)†

    Science.gov (United States)

    Shrestha, Malakh; Baraki, Hassina; Maeding, Ilona; Fitzner, Sebastian; Sarikouch, Samir; Khaladj, Nawid; Hagl, Christian; Haverich, Axel

    2012-01-01

    OBJECTIVE Aortic valve-sparing David procedure has gained broad acceptance. However, few long-term results have been published. We present our results. METHODS More than 450 David procedures have been performed in our institution so far. Of these, 126 patients were operated between July 1993 and December 2000. Median age was 57 (8–83) years and 46 (36.5%) were female. As many as 26 (20.6%) had Marfan syndrome, 21 (16.7%) had acute aortic dissection type A (AADA) and 67 (53.2%) had additional procedures. RESULTS There were six (4.8%) deaths in 30 post-operative period (POD), four of whom had AADA. In the follow-up, there were 32 (25.4%) late deaths, 11 (34.4%) of these were caused by cardiac or underlying disease or op-related. As many as 15 (11.9%) patients were re-operated; six (40%) were Marfan patients and two (13.3%) had early endocarditis. Follow-up echocardiography of 76 (60.3%) event-free patients showed valve insufficiency (AI) ≤ AI I° in 68 (89.5%) and grade II in 7 (9.2%) patients. Leaflet degeneration due to proposed leaflet contact with the straight Dacron graft was not observed. A total of 36 (47.4%) patients were in New York Heart Association (NYHA) class I, 33 (43.4%) in NYHA II, and five (6.6%) were in class III. During the entire follow-up of 790 patient-years, there was no stroke or major bleeding. Survival at 1, 5 and 10 years was 93%, 85% and 70%, respectively. Freedom from valve replacement at 1, 5 and 10 years was 96%, 91% and 87%, respectively. CONCLUSIONS: Regardless of the underlying pathology, valve-sparing David I procedure has acceptable long-term results. Valve-related complications such as stroke or major bleeding is exceedingly low. PMID:21632258

  3. Performance of the LAr scintillation veto of GERDA Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wiesinger, Christoph [Technische Universitaet Muenchen, Physik Dept. E15, James-Franck-Strasse, 85748 Garching (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay in {sup 76}Ge. Results of Phase I have been published in summer 2013 and Gerda is upgraded to Phase II. To reach the aspired background index of ≤ 10{sup -3} cts/(keV.kg.yr) for Phase II active background-suppression techniques are applied, including an active liquid argon (LAr) veto. It has been demonstrated with the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in the LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  4. The SafeBoosC phase II clinical trial

    DEFF Research Database (Denmark)

    Riera, Joan; Hyttel-Sorensen, Simon; Bravo, María Carmen

    2016-01-01

    BACKGROUND: The SafeBoosC phase II randomised clinical trial recently demonstrated the benefits of a combination of cerebral regional tissue oxygen saturation (rStO2) by near-infrared spectroscopy (NIRS) and a treatment guideline to reduce the oxygen imbalance in extremely preterm infants. AIMS: ...

  5. Advanced Technology Cloud Particle Probe for UAS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In Phase II SPEC will design, fabricate and flight test a state-of-the-art combined cloud particle probe called the Hawkeye. Hawkeye is the culmination of two...

  6. Composite Structure Monitoring using Direct Write Sensors, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This NASA SBIR Phase II project seeks to develop and demonstrate a suite of sensor products to monitor the health of composite structures. Sensors will be made using...

  7. Improved Lunar and Martian Regolith Simulant Production, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The technical objective of the Phase II project is to provide a more complete investigation of the long-term needs of the simulant community based on the updated...

  8. Surgical treatment of tricuspid valve insufficiency promotes early reverse remodeling in patients with axial-flow left ventricular assist devices.

    Science.gov (United States)

    Maltais, Simon; Topilsky, Yan; Tchantchaleishvili, Vakhtang; McKellar, Stephen H; Durham, Lucian A; Joyce, Lyle D; Daly, Richard C; Park, Soon J

    2012-06-01

    The HeartMate II (Thoratec Corp, Pleasanton, Calif) continuous-flow left ventricular assist device has emerged as the standard of care for patients with advanced heart failure. The objective of this study was to assess the safety and early effectiveness of concomitant tricuspid valve procedures in patients undergoing implantation of a HeartMate II device. From February 2007 to April 2010, 83 patients underwent HeartMate II left ventricular assist device implantation. Of these, 37 patients had concomitant tricuspid valve procedures (32 repairs, 5 replacements) for severe tricuspid regurgitation. The effects of a tricuspid valve procedure on tricuspid regurgitation and right ventricular remodeling were assessed comparing echocardiographic findings at baseline and 30 days after left ventricular assist device implantation. Overall survival was also compared. Patients undergoing a concomitant tricuspid valve procedure had more tricuspid regurgitation (vena contracta, 5.6 ± 2.1 mm vs 2.9 ± 2.0 mm; P tricuspid regurgitation was worse in patients who underwent left ventricular assist device implantation alone (+18.6%), whereas it improved significantly in patients undergoing a concomitant tricuspid valve procedure (-50.2%) (P = .005). A corresponding significant reduction in right ventricular end-diastolic area (33.6% ± 6.2% vs 30.1% ± 9.7%; P = .03) and a trend toward better right ventricular function (55.5% ± 79.7% vs 35.7% ± 60.5%; P = .28) were noted in patients undergoing a concomitant tricuspid valve procedure. Survival was comparable between the 2 groups. In patients with severe tricuspid regurgitation undergoing left ventricular assist device implantation, a concomitant tricuspid valve procedure effectively reduces tricuspid regurgitation and promotes reverse remodeling of the right ventricle. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. Velocity and shear stress distribution downstream of mechanical heart valves in pulsatile flow.

    Science.gov (United States)

    Giersiepen, M; Krause, U; Knott, E; Reul, H; Rau, G

    1989-04-01

    Ten mechanical valves (TAD 27 mm): Starr-Edwards Silastic Ball, Björk-Shiley Standard, Björk-Shiley Concave-Convex, Björk-Shiley Monostrut, Hall-Kaster (Medtronic-Hall), OmniCarbon, Bicer Val, Sorin, Saint-Jude Medical and Hemex (Duromedics) are investigated in a comparative in vitro study. The velocity and turbulent shear stress profiles of the valves were determined by Laser Doppler anemometry in two different downstream axes within a model aortic root. Depending on the individual valve design, velocity peaks up to 1.5 m/s and turbulent shear stress peaks up to 150 N/m2 were measured during the systolic phase. These shear stress peaks mainly occurred in areas of flow separation and intense momentum exchange. Directly downstream of the valves (measuring axis 0.55.dAorta) turbulent shear stress peaks occurred at peak systole and during the deceleration phase, while in the second measuring axis (1.5.dAorta) turbulence levels were lower. Shear stress levels were high at the borders of the fluid jets. The results are discussed from a fluid-dynamic point of view.

  10. TNX GeoSiphon Cell (TGSC-1) Phase II Single Cell Deployment/Demonstration Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Phifer, M.A.

    1999-04-15

    This Phase II final report documents the Phase II testing conducted from June 18, 1998 through November 13, 1998, and it focuses on the application of the siphon technology as a sub-component of the overall GeoSiphon Cell technology. [Q-TPL-T-00004

  11. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  12. Spray Forming Aluminum - Final Report (Phase II)

    Energy Technology Data Exchange (ETDEWEB)

    D. D. Leon

    1999-07-08

    The U.S. Department of Energy - Office of Industrial Technology (DOE) has an objective to increase energy efficient and enhance competitiveness of American metals industries. To support this objective, ALCOA Inc. entered into a cooperative program to develop spray forming technology for aluminum. This Phase II of the DOE Spray Forming Program would translate bench scale spray forming technology into a cost effective world class process for commercialization. Developments under DOE Cooperative Agreement No. DE-FC07-94ID13238 occurred during two time periods due to budgetary constraints; April 1994 through September 1996 and October 1997 and December 1998. During these periods, ALCOA Inc developed a linear spray forming nozzle and specific support processes capable of scale-up for commercial production of aluminum sheet alloy products. Emphasis was given to alloys 3003 and 6111, both being commercially significant alloys used in the automotive industry. The report reviews research performed in the following areas: Nozzel Development, Fabrication, Deposition, Metal Characterization, Computer Simulation and Economics. With the formation of a Holding Company, all intellectual property developed in Phases I and II of the Project have been documented under separate cover for licensing to domestic producers.

  13. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  14. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  15. Space Qualified Non-Destructive Evaluation and Structural Health Monitoring Technology, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Encouraged by Phase I accomplishments, the proposed Phase II program will significantly mature and align the development of a Space Qualified Non-Destructive...

  16. Solid phase selective separation and preconcentration of Cu(II) by Cu(II)-imprinted polymethacrylic microbeads.

    Science.gov (United States)

    Dakova, Ivanka; Karadjova, Irina; Ivanov, Ivo; Georgieva, Ventsislava; Evtimova, Bisera; Georgiev, George

    2007-02-12

    Ion-imprinted polymer (IIP) particles are prepared by copolymerization of methacrylic acid as monomer, trimethylolpropane trimethacrylate as crosslinking agent and 2,2'-azo-bis-isobutyronitrile as initiator in the presence of Cu(II), a Cu(II)-4-(2-pyridylazo)resorcinol (Cu(II)-PAR) complex, and PAR only. A batch procedure is used for the determination of the characteristics of the Cu(II) solid phase extraction from the IIP produced. The results obtained show that the Cu(II)-PAR IIP has the greatest adsorption capacity (37.4 micromol g(-1) of dry copolymer) among the IIPs investigated. The optimal pH value for the quantitative preconcentration is 7, and full desorption is achieved by 1 M HNO(3). The selectivity coefficients (S(Cu/Me)) for Me=Ni(II), Co(II) are 45.0 and 38.5, respectively. It is established that Cu(II)-PAR IIPs can be used repeatedly without a considerable adsorption capacity loss. The determination of Cu(II) ions in seawater shows that the interfering matrix does not influence the preconcentration and selectivity values of the Cu(II)-PAR IIPs. The detection and quantification limits are 0.001 micromol L(-1) (3sigma) and 0.003 micromol L(-1) (6sigma), respectively.

  17. South Bay Salt Pond Restoration, Phase II at Ravenswood

    Science.gov (United States)

    Information about the South Bay Salt Pond Restoration Project: Phase II Construction at Ravenswood, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic resources.

  18. InGaN High Temperature Photovoltaic Cells, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The objectives of this Phase II project are to develop InGaN photovoltaic cells for high temperature and/or high radiation environments to TRL 4 and to define the...

  19. Cash Impact of the Consumable Item Transfer, Phase II

    National Research Council Canada - National Science Library

    1998-01-01

    ...). This report is the third in a series of reports regarding the consumable item transfer (CIT), phase II. The Deputy Secretary of Defense directed the transfer of the management of consumable items to Defense Logistics Agency...

  20. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  1. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  2. A Tool for Predicting Regulatory Approval After Phase II Testing of New Oncology Compounds.

    Science.gov (United States)

    DiMasi, J A; Hermann, J C; Twyman, K; Kondru, R K; Stergiopoulos, S; Getz, K A; Rackoff, W

    2015-11-01

    We developed an algorithm (ANDI) for predicting regulatory marketing approval for new cancer drugs after phase II testing has been conducted, with the objective of providing a tool to improve drug portfolio decision-making. We examined 98 oncology drugs from the top 50 pharmaceutical companies (2006 sales) that first entered clinical development from 1999 to 2007, had been taken to at least phase II development, and had a known final outcome (research abandonment or regulatory marketing approval). Data on safety, efficacy, operational, market, and company characteristics were obtained from public sources. Logistic regression and machine-learning methods were used to provide an unbiased approach to assess overall predictability and to identify the most important individual predictors. We found that a simple four-factor model (activity, number of patients in the pivotal phase II trial, phase II duration, and a prevalence-related measure) had high sensitivity and specificity for predicting regulatory marketing approval. © 2015 American Society for Clinical Pharmacology and Therapeutics.

  3. Mechanical Engineering and Design of the LHC Phase II Collimators

    CERN Document Server

    Bertarelli, A; Gentini, L; Mariani, N; Perret, R; Timmins, M A

    2010-01-01

    Phase II collimators will complement the existing system to improve the expected high RF impedance and limited efficiency of Phase I jaws. An international collaborative effort has been launched to identify novel advanced materials responding to the very challenging requirements of the new collimators. Complex numerical calculations simulating extreme conditions and experimental tests are in progress. In parallel, an innovative modular design concept of the jaw assembly is being developed to allow fitting in alternative materials, minimizing the thermally induced deformations, withstanding accidents and accepting high radiation doses. Phase II jaw assembly is made up of a molybdenum back-stiffener ensuring high geometrical stability and a modular jaw split in threes sectors. Each sector is equipped with a high-efficiency independent cooling circuit. Beam position monitors (BPM) are embedded in the jaws to fasten setup time and improve beam monitoring. An adjustment system will permit to fine-tune the jaw flat...

  4. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  5. Superconducting spin valves controlled by spiral re-orientation in B20-family magnets

    Science.gov (United States)

    Pugach, N. G.; Safonchik, M.; Champel, T.; Zhitomirsky, M. E.; Lähderanta, E.; Eschrig, M.; Lacroix, C.

    2017-10-01

    We propose a superconducting spin-triplet valve, which consists of a superconductor and an itinerant magnetic material, with the magnet showing an intrinsic non-collinear order characterized by a wave vector that may be aligned in a few equivalent preferred directions under the control of a weak external magnetic field. Re-orienting the spiral direction allows one to controllably modify long-range spin-triplet superconducting correlations, leading to spin-valve switching behavior. Our results indicate that the spin-valve effect may be noticeable. This bilayer may be used as a magnetic memory element for cryogenic nanoelectronics. It has the following advantages in comparison to superconducting spin valves proposed previously: (i) it contains only one magnetic layer, which may be more easily fabricated and controlled; (ii) its ground states are separated by a potential barrier, which solves the "half-select" problem of the addressed switch of memory elements.

  6. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  7. Post Process Characterization of Friction Stir Welded Components, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Luna Innovations Incorporated proposes in this STTR Phase II project to continue development and validation of Luna's amplitude-dependent, nonlinear ultrasonic...

  8. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  9. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  10. LAr instrumentation for Gerda phase II

    Energy Technology Data Exchange (ETDEWEB)

    Wegmann, Anne [Max-Planck-Institut fuer Kernphysik, Heidelberg (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    Gerda is an experiment to search for the neutrinoless double beta decay of {sup 76}Ge. Results of Phase I have been published in summer 2013. Currently the commissioning of Gerda Phase II is ongoing. To reach the aspired background index of ≤10{sup -3} cts/(keV.kg.yr) active background-suppression techniques will be applied, including an active liquid argon veto (LAr veto). It has been demonstrated by the LArGe test facility that the detection of argon scintillation light can be used to effectively suppress background events in the germanium, which simultaneously deposit energy in LAr. The light instrumentation consisting of photomultiplier tubes (PMT) and wavelength-shifting fibers connected to silicon multipliers (SiPM) has been installed in Gerda. In this talk the low background design of the LAr veto and its performance during the commissioning runs are reported.

  11. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  12. Options Study - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    R. Wigeland; T. Taiwo; M. Todosow; W. Halsey; J. Gehin

    2010-09-01

    The Options Study has been conducted for the purpose of evaluating the potential of alternative integrated nuclear fuel cycle options to favorably address the issues associated with a continuing or expanding use of nuclear power in the United States. The study produced information that can be used to inform decisions identifying potential directions for research and development on such fuel cycle options. An integrated nuclear fuel cycle option is defined in this study as including all aspects of the entire nuclear fuel cycle, from obtaining natural resources for fuel to the ultimate disposal of used nuclear fuel (UNF) or radioactive wastes. Issues such as nuclear waste management, especially the increasing inventory of used nuclear fuel, the current uncertainty about used fuel disposal, and the risk of nuclear weapons proliferation have contributed to the reluctance to expand the use of nuclear power, even though it is recognized that nuclear power is a safe and reliable method of producing electricity. In this Options Study, current, evolutionary, and revolutionary nuclear energy options were all considered, including the use of uranium and thorium, and both once-through and recycle approaches. Available information has been collected and reviewed in order to evaluate the ability of an option to clearly address the challenges associated with the current implementation and potential expansion of commercial nuclear power in the United States. This Options Study is a comprehensive consideration and review of fuel cycle and technology options, including those for disposal, and is not constrained by any limitations that may be imposed by economics, technical maturity, past policy, or speculated future conditions. This Phase II report is intended to be used in conjunction with the Phase I report, and much information in that report is not repeated here, although some information has been updated to reflect recent developments. The focus in this Options Study was to

  13. Multifunctional Metal/Polymer Composite Fiber for Space Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Small Business Innovation Research Phase II Program, Syscom Technology, Inc. will implement an integrated processing scheme to fabricate a conductive...

  14. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  15. Theoretical study of a novel refrigeration compressor - Part II: Performance of a rotating discharge valve in the revolving vane (RV) compressor

    Energy Technology Data Exchange (ETDEWEB)

    Teh, Y.L.; Ooi, K.T. [Thermal and Fluids Engineering Division, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, S639798 (Singapore); Djamari, D. Wibowo [Engineering Mechanics Division, School of Mechanical and Aerospace Engineering, Nanyang Technological University, 50 Nanyang Avenue, S639798 (Singapore)

    2009-08-15

    A new refrigeration compressor, named 'Revolving Vane (RV) compressor', has been introduced in Part I of this paper series. For a first time in refrigeration compressors, a rotating discharge valve is employed in the RV compressor mainly due to the rotation of the entire cylinder. This paper presents a theoretical investigation on the dynamic behavior of a reed-type discharge valve undergoing rotatory motion, with the primary objective of elucidating the applicability of such valves in refrigeration compressors. Under the application of the Euler-Bernoulli beam theory, a mathematical model of the rotating valve is formulated and the transient response of the valve under centrifugal loads in addition to pressure forces is analyzed. Results have shown that under careful design considerations, the performance as well as the reliability of the rotating discharge valve can be enhanced as compared to a non-rotating valve that has been used in all refrigeration compressors currently. (author)

  16. Low Load Limit Extension for Gasoline Compression Ignition Using Negative Valve Overlap Strategy

    KAUST Repository

    Vallinayagam, R.

    2018-04-03

    Gasoline compression ignition (GCI) is widely studied for the benefits of simultaneous reduction in nitrogen oxide (NO) and soot emissions without compromising the engine efficiency. Despite this advantage, the operational range for GCI is not widely expanded, as the auto-ignition of fuel at low load condition is difficult. The present study aims to extend the low load operational limit for GCI using negative valve overlap (NVO) strategy. The engine used for the current experimentation is a single cylinder diesel engine that runs at an idle speed of 800 rpm with a compression ratio of 17.3. The engine is operated at homogeneous charge compression ignition (HCCI) and partially premixed combustion (PPC) combustion modes with the corresponding start of injection (SOI) at 180 CAD (aTDC) and 30 CAD (aTDC), respectively. In the presented work, intake air temperature is used as control parameter to maintain combustion stability at idle and low load condition, while the intake air pressure is maintained at 1 bar (ambient). The engine is equipped with variable valve cam phasers that can phase both inlet and exhaust valves from the original timing. For the maximum cam phasing range (56 CAD) at a valve lift of 0.3 mm, the maximum allowable positive valve overlap was 20 CAD. In the present study, the exhaust cam is phased to 26 CAD and 6 CAD and the corresponding NVO is noted to be 10 CAD and 30 CAD, respectively. With exhaust cam phasing adjustment, the exhaust valve is closed early to retain hot residual gases inside the cylinder. As such, the in-cylinder temperature is increased and a reduction in the required intake air temperature to control combustion phasing is possible. For a constant combustion phasing of 3 CAD (aTDC), a minimum load of indicated mean effective pressure (IMEP) = 1 bar is attained for gasoline (RON = 91) at HCCI and PPC modes. The coefficient of variance was observed to below 5% at these idle and low load conditions. At the minimum load point, the

  17. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  18. A Nanodroplet Processor for Advanced Microencapsulated Drug Formulations, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — During this Phase II program we propose to build on the key aspects of the nanodroplet encapsulation technology to demonstrate optimized formulation and...

  19. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  20. Project NOAH: Regulating modern sea-level rise. Phase II: Jerusalem Underground

    Science.gov (United States)

    Newman, Walter S.; Fairbridge, Rhodes W.

    This proposal builds a high-speed inter-urban express between Jerusalem and Tel Aviv, generates 1500 megawatts of hydroelectric energy, curtails littoral erosion, builds a port along the Israeli Mediterranean coast and demands peaceful cooperation on both sides of the Jordan River. Phase II represents a pilot project demonstrating the feasibility of continuing to regulate world sea-level by a new series of water regulation schemes. Phase I previously described all those projects already completed or underway which have inadvertently and/or unintentionally served the purpose of sea-level regulation. These forms of Phase I sea-level regulation include large and small reservoirs, irrigation projects, water infiltration schemes, farm ponds, and swimming and reflecting pools. All these water storage projects have already exercised a very appreciable brake on 20th century sea-level rise. Phase II outlines a high-visibility proposal which will serve to illustrate the viability of “Project NOAH”.

  1. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  2. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  3. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  4. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  5. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  6. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  7. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  8. FALSIRE Phase II. CSNI project for Fracture Analyses of Large-Scale International Reference Experiments (Phase II). Comparison report

    International Nuclear Information System (INIS)

    Sievers, J.; Schulz, H.; Bass, R.; Pugh, C.; Keeney, J.

    1996-11-01

    A summary of Phase II of the Project for Fracture Analysis of Large-Scale International Reference Experiments (FALSIRE) is presented. A FALSIRE II Workshop focused on analyses of reference fracture experiments. More than 30 participants representing 22 organizations from 12 countries took part in the workshop. Final results for 45 analyses of the reference experiments were received from the participating analysts. For each experiment, analysis results provided estimates of variables that include temperature, crack-mouth-opening displacement, stress, strain, and applied K and J values. The data were sent electronically to the Organizing Committee, who assembled the results into a comparative data base using a special-purpose computer program. A comparative assessment and discussion of the analysis results are presented in the report. Generally, structural responses of the test specimens were predicted with tolerable scatter bands. (orig./DG)

  9. Multifunctional Aerogel Thermal Protection Systems for Hypersonic Vehicles, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The overall objective of the Phase II project is to develop lightweight reinforced aerogel materials for use as the core structural insulation material in...

  10. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  11. Crygenic performance of a superfluid helium relief valve for the LHC superconducting magnets

    International Nuclear Information System (INIS)

    Danielsson, H.; Ferlin, G.; Luguet, C.

    1996-01-01

    The high-field superconducting magnets of the Large Hadron Collider (LHC) project at CERN will operate below 1.9 K in static baths of pressurized helium II. In case of resistive transition (open-quotes quenchclose quotes), the resulting pressure rise in the cryostats must be limited to below their 2 MPa design pressure. This is achieved by discharging helium at high flow-rates into a cold recovery header, normally maintained at 20 K. For this purpose, the authors have designed, built and tested a cryogenic quench relief valve with a nominal diameter of 50 mm and an opening time of below 0.1 s. The valve, which can be opened on an external trigger, also acts as a relief device actuated by the upstream pressure when it exceeds 0.4 MPa. In normal operation, the closed poppet must be helium-tight, for hydraulic and thermal separation of the magnet baths from the recovery header. Following mechanical qualification tests under vacuum, the authors have mounted the relief valve in a dedicated cryogenic measuring bench, in order to perform precision thermal measurements with pressurized helium II

  12. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  13. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  14. Phase I and II feasibility study report for the 300-FF-5 operable unit

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1993-12-31

    The purpose of this Phase I/II feasibility study is to assemble and screen a list of alternatives for remediation of the 300-FF-5 operable site on the Hanford Reservation. This screening is based on information gathered in the Phase I Remedial Investigation (RI) and on currently available information on remediation technologies. The alternatives remaining after screening provide a range of response actions for remediation. In addition, key data needs are identified for collection during a Phase II RI (if necessary). This Phase I/II FS represents a primary document as defined by the Tri-Party Agreement, but will be followed by a Phase III FS that will further develop the alternatives and provide a detailed evaluation of them. The following remedial action objectives were identified for the 300-FF-5 operable unit: Limit current human exposure to contaminated groundwater in the unit; Limit discharge of contaminated groundwater to the Columbia River; Reduce contaminant concentrations in groundwater below acceptable levels by the year 2018.

  15. Phase I and II feasibility study report for the 300-FF-5 operable unit

    International Nuclear Information System (INIS)

    1993-01-01

    The purpose of this Phase I/II feasibility study is to assemble and screen a list of alternatives for remediation of the 300-FF-5 operable site on the Hanford Reservation. This screening is based on information gathered in the Phase I Remedial Investigation (RI) and on currently available information on remediation technologies. The alternatives remaining after screening provide a range of response actions for remediation. In addition, key data needs are identified for collection during a Phase II RI (if necessary). This Phase I/II FS represents a primary document as defined by the Tri-Party Agreement, but will be followed by a Phase III FS that will further develop the alternatives and provide a detailed evaluation of them. The following remedial action objectives were identified for the 300-FF-5 operable unit: Limit current human exposure to contaminated groundwater in the unit; Limit discharge of contaminated groundwater to the Columbia River; Reduce contaminant concentrations in groundwater below acceptable levels by the year 2018

  16. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  17. Platypnea-Orthodeoxia Syndrome after Transcatheter Aortic Valve Implantation

    Directory of Open Access Journals (Sweden)

    Andrew K. Roy

    2016-01-01

    Full Text Available Progressive dyspnea and hypoxaemia in the subacute phase after transcatheter aortic valve implantation (TAVI are uncommon and warrant immediate assessment of valve and prosthesis leaflet function to exclude thrombosis, as well as investigation for other causes related to the procedure, such as left ventricular dysfunction, pulmonary embolism, and respiratory sepsis. In this case, we report the observation of a patient presenting two weeks after TAVI with arterial hypoxaemia in an upright position, relieved by lying flat, and coupled with an intracardiac shunt detected on echocardiography in the absence of pulmonary hypertension, raising the suspicion of Platypnea-Orthodeoxia Syndrome (POS. Invasive intracardiac haemodynamic assessment showed a significant right-to-left shunt (Qp/Qs = 0.74, which confirmed the diagnosis, with subsequent closure of the intracardiac defect resulting in immediate relief of symptoms and hypoxaemia. To our knowledge, this is the first reported case of an interatrial defect and shunt causing Platypnea-Orthodeoxia Syndrome after transcatheter aortic valve implantation, resolved by percutaneous device closure.

  18. Deployable Engine Air-Brake for Drag Management Applications, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — ATA Engineering, Inc., (ATA) proposes a Phase II SBIR program to demonstrate an innovative engine air-brake (EAB) technology that uses a deployable swirl vane...

  19. Small Business Innovation Research, Post-Phase II Opportunity Assessment

    Science.gov (United States)

    Nguyen, Hung D.; Steele, Gynelle C.

    2015-01-01

    This report outlines current Small Business Innovation Research (SBIR) Post-Phase II opportunity contract award results for the SBIR technology program from 2007 to 2011 for NASA's Aeronautics Research Mission Directorate (ARMD), Human Exploration and Operations Mission Directorate (HEOMD), Science Mission Directorate (SMD), and Space Technology Mission Directorate (STMD). The report provides guidelines for incorporating SBIR technology into NASA programs and projects and provides a quantitative overview of the post-Phase II award patterns that correspond with each mission directorate at NASA Glenn Research Center (GRC). In recent years, one of NASA's goals has been to not only transfer SBIR technologies to commercial industries, but to ensure that NASA mission directorates incorporate SBIR technologies into their program and project activities. Before incorporating technologies into MD programs, it is important to understand each mission directorate structure because each directorate has different objectives and needs. The directorate program structures follow.

  20. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Warren, Tracy A [ORNL; Walker, Randy M [ORNL; Hill, David E [ORNL; Gross, Ian G [ORNL; Smith, Cyrus M [ORNL; Abercrombie, Robert K [ORNL

    2008-12-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies.

  1. RadSTraM: Radiological Source Tracking and Monitoring, Phase II Final Report

    International Nuclear Information System (INIS)

    Warren, Tracy A.; Walker, Randy M.; Hill, David E.; Gross, Ian G.; Smith, Cyrus M.; Abercrombie, Robert K.

    2008-01-01

    This report focuses on the technical information gained from the Radiological Source Tracking and Monitoring (RadSTraM) Phase II investigation and its implications. The intent of the RadSTraM project was to determine the feasibility of tracking radioactive materials in commerce, particularly International Atomic Energy Agency (IAEA) Category 3 and 4 materials. Specifically, Phase II of the project addressed tracking radiological medical isotopes in commerce. These categories of materials are susceptible to loss or theft but the problem is not being addressed by other agencies

  2. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  3. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  4. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  5. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  6. The effect of varying degrees of stenosis on the characteristics of turbulent pulsatile flow through heart valves.

    Science.gov (United States)

    Bluestein, D; Einav, S

    1995-08-01

    Many problems and complications associated with heart valves are related to the dynamic behavior of the valve and the resultant unsteady flow patterns. An accurate depiction of the spatial and temporal velocity and rms distributions imparts better understanding of flow related valve complications, and may be used as a guideline in valve design. While the generalized correlation between increased turbulence level and the severity of the stenosis is well established, few studies addressed the issue of the intermittent nature of turbulence and its timing in the cardiac cycle, and almost none assessed the effect of a progressive stenosis on the flow characteristics through heart valves. In this experimental work we simulated the type of flow which is present in normal and stenosed valves and conducted a comprehensive investigation of valve hemodynamics, valvular turbulence and morphology under varying degrees of stenosis. The characteristics of valves and stenoses were simulated closely, to achieve the flow conditions that initiate turbulent flow conditions. Laser Doppler anemometry (LDA) measurements were carried out in a pulse duplicator system distal to trileaflet polyurethane prosthetic heart valves, installed at mitral and aortic positions. The effect of the degree of the stenosis was comparatively studied through the structure of the turbulent jets emerging from normal and stenotic heart valves. Maximum turbulence level was achieved during the decelerating phase and correlated to the severity of the stenosis, followed by relaminarization of the flow during the acceleration phase. The intermittent nature of the turbulence emphasized the importance of realizing the timing of the turbulence production and its spatial location for optimizing current valve designs. The plug flow through the normal aortic valve prosthesis was replaced by jet like behavior for a 65% stenosis, with the jet becoming narrower and stronger for a 90% stenosis. The morphology of the velocity

  7. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  8. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  9. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  10. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  11. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  12. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  13. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  14. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  15. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  16. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  17. Performance of GERDA phase II BEGe detectors

    Energy Technology Data Exchange (ETDEWEB)

    Wagner, Victoria [Max-Planck Institut fuer Kernphysik (Germany); Collaboration: GERDA-Collaboration

    2015-07-01

    The GERDA experiment searches for the lepton number violating neutrinoless double beta (0νββ) decay of {sup 76}Ge. GERDA uses HPGe detectors enriched in {sup 76}Ge as source and detection material. The experiment proceeds in two phases. In Phase I a background index of 10{sup -2} cts/(keV.kg.yr) was reached and a new lower limit on the half-life of the 0νββ decay of {sup 76}Ge was set to 2.1.10{sup 25} yr (at 95% C.L.). In Phase II the background index will be lowered by an order of magnitude and a sensitivity of 10{sup 26} yr will be reached. In order to achieve this goal 30 new custom-made broad energy germanium (BEGe) detectors and a liquid argon scintillation light veto will be deployed. Five BEGe detectors have been operated successfully in Phase I and demonstrated their improved energy resolution and enhanced pulse shape discrimination (PSD) against background events. Special designed electronics will further improve energy resolution and PSD performance. The first results from commissioning of the new BEGe detectors are presented in this talk.

  18. Near net shape, low cost ceramic valves for advanced engine applications

    Energy Technology Data Exchange (ETDEWEB)

    Pidria, M.; Merlone, E.; Parussa, F. [Fiat Research Centre, Orbassano (Italy); Handelsman, J.; Gorodnev, A. [Ceracom Materials Ltd., Yavneh (Israel)

    2003-07-01

    Future gasoline and diesel engines with electro-hydraulic or electro-mechanical valve control systems require the development of lighter valves to achieve the best results in terms of increased performances, lower fuel consumption and overall efficiency. Ceramic materials can adequately satisfy the required mechanical and thermal properties, nevertheless they still lack as far as manufacturing costs are concerned. Objective of the work was the development of a low-cost forming and sintering process, to produce near-net shape ceramic valves thus requiring very low finishing operations and significantly minimizing material waste. Between available technical ceramic materials, silicon nitride has been chosen to replace conventional steels and Ni-based alloys for the exhaust valves application. The work was then devoted to (i) the selection of the best starting materials composition, taking into account the requirements of a cost effective and high volume production, (ii) the development of an innovative pressure-injection molding process to produce near-net shape parts via a thermosetting feedstock and (iii) the optimization of a proper pressure-less sintering route to obtain cost-competitive, real scale components with adequate final density and mechanical properties. (orig.)

  19. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  20. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  1. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  2. One-year multicentre outcomes of transapical aortic valve implantation using the SAPIEN XT™ valve: the PREVAIL transapical study.

    Science.gov (United States)

    Walther, Thomas; Thielmann, Matthias; Kempfert, Joerg; Schroefel, Holger; Wimmer-Greinecker, Gerhard; Treede, Hendrik; Wahlers, Thorsten; Wendler, Olaf

    2013-05-01

    The study aimed to evaluate 1-year outcomes of the multicentre PREVAIL transapical (TA) study of TA-aortic valve implantation (AVI) in high-risk patients. From September 2009 to August 2010, a total of 150 patients, aged 81.6 ± 5.8 years, 40.7% female, were included at 12 European TA-AVI experienced sites. Patients received 23 (n = 36), 26 (n = 57) and 29 mm (n = 57) second-generation SAPIEN XT™ (Edwards Lifesciences, Irvine, CA, USA) valves. The mean logistic EuroSCORE was 24.3 ± 7.0, and mean Society Thoracic Surgeons score was 7.5 ± 4.4%. Survival was 91.3% at 30 days and 77.9% at 1 year. Subgroup analysis revealed survivals of 91.7/88.9, 86.0/70.2, 96.55/91.2% for patients receiving 23-, 26- and 29-mm valves at 30 days and at 1 year, respectively. Transthoracic echocardiography revealed preserved left ventricular ejection fraction and low gradients. Aortic incompetence was none in 41/48, trace 30/36, mild 22/12 and moderate in 7/4% at discharge and 1 year. Walking distance increased from 221 (postimplant) to 284 m (at 1 year, P = 0.0004). Three patients required reoperation due to increasing aortic incompetence during follow-up. Causes of mortality at 1 year were cardiac (n = 7), stroke (n = 1) and others (n = 5). The European PREVAIL multicentre trial demonstrates good functionality and good outcomes for TA-AVI using the second-generation SAPIEN XT prosthesis and the ASCENDRA-II delivery system. The 29-mm SAPIEN XT valve was successfully introduced and showed excellent results.

  3. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  4. Search for neutrinoless double beta decay with GERDA phase II

    Science.gov (United States)

    Agostini, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Bettini, A.; Bezrukov, L.; Bode, T.; Borowicz, D.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; D'Andrea, V.; Demidova, E. V.; Di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Gangapshev, A.; Garfagnini, A.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hofmann, W.; Hult, M.; Inzhechik, L. V.; Csáthy, J. Janicskó; Jochum, J.; Junker, M.; Kazalov, V.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knies, J.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lebedev, V. I.; Liao, H. Y.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Majorovits, B.; Maneschg, W.; Marissens, G.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Ransom, C.; Reissfelder, M.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Salamida, F.; Schmitt, C.; Schneider, B.; Schönert, S.; Schreiner, J.; Schulz, O.; Schütz, A.-K.; Schwingenheuer, B.; Seitz, H.; Selivanenko, O.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zuber, K.; Zuzel, G.

    2017-10-01

    The GERmanium Detector Array (gerda) experiment, located at the Gran Sasso underground laboratory in Italy, is one of the leading experiments for the search of 0νββ decay. In Phase II of the experiment 35.6 kg of enriched germanium detectors are operated. The application of active background rejection methods, such as a liquid argon scintillation light read-out and pulse shape discrimination of germanium detector signals, allowed to reduce the background index to the intended level of 10-3 cts/(keV.kg.yr). In the first five month of data taking 10.8 kg yr of exposure were accumulated. No signal has been found and together with data from Phase I a new limit for the neutrinoless double beta decay half-life of 76Ge of 5.3 . 1025 yr at 90% C.L. was established in June 2016. Phase II data taking is ongoing and will allow the exploration of half-lifes in the 1026 yr regime. The current status of data taking and an update on the background index are presented.

  5. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  6. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  7. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  8. Pretest Predictions for Phase II Ventilation Tests

    International Nuclear Information System (INIS)

    Yiming Sun

    2001-01-01

    The objective of this calculation is to predict the temperatures of the ventilating air, waste package surface, and concrete pipe walls that will be developed during the Phase II ventilation tests involving various test conditions. The results will be used as inputs to validating numerical approach for modeling continuous ventilation, and be used to support the repository subsurface design. The scope of the calculation is to identify the physical mechanisms and parameters related to thermal response in the Phase II ventilation tests, and describe numerical methods that are used to calculate the effects of continuous ventilation. The calculation is limited to thermal effect only. This engineering work activity is conducted in accordance with the ''Technical Work Plan for: Subsurface Performance Testing for License Application (LA) for Fiscal Year 2001'' (CRWMS M and O 2000d). This technical work plan (TWP) includes an AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering, and Regulatory Compliance Activities'', activity evaluation (CRWMS M and O 2000d, Addendum A) that has determined this activity is subject to the YMP quality assurance (QA) program. The calculation is developed in accordance with the AP-3.12Q procedure, ''Calculations''. Additional background information regarding this activity is contained in the ''Development Plan for Ventilation Pretest Predictive Calculation'' (DP) (CRWMS M and O 2000a)

  9. Fluid-structure interaction analysis of the flow through a stenotic aortic valve

    Science.gov (United States)

    Maleki, Hoda; Labrosse, Michel R.; Durand, Louis-Gilles; Kadem, Lyes

    2009-11-01

    In Europe and North America, aortic stenosis (AS) is the most frequent valvular heart disease and cardiovascular disease after systemic hypertension and coronary artery disease. Understanding blood flow through an aortic stenosis and developing new accurate non-invasive diagnostic parameters is, therefore, of primarily importance. However, simulating such flows is highly challenging. In this study, we considered the interaction between blood flow and the valve leaflets and compared the results obtained in healthy valves with stenotic ones. One effective method to model the interaction between the fluid and the structure is to use Arbitrary Lagrangian-Eulerian (ALE) approach. Our two-dimensional model includes appropriate nonlinear and anisotropic materials. It is loaded during the systolic phase by applying pressure curves to the fluid domain at the inflow. For modeling the calcified stenotic valve, calcium will be added on the aortic side of valve leaflets. Such simulations allow us to determine the effective orifice area of the valve, one of the main parameters used clinically to evaluate the severity of an AS, and to correlate it with changes in the structure of the leaflets.

  10. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  11. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  12. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  13. South Bay Salt Pond Tidal Wetland Restoration Phase II Planning

    Science.gov (United States)

    Information about the SFBWQP South Bay Salt Pond Tidal Wetland Restoration Phase II Planning project, part of an EPA competitive grant program to improve SF Bay water quality focused on restoring impaired waters and enhancing aquatic re

  14. An Experimental Evaluation of Hyperactivity and Food Additives. 1977-Phase II.

    Science.gov (United States)

    Harley, J. Preston; And Others

    Phase II of a study on the effectiveness of B. Feingold's recommended diet for hyperactive children involved the nine children (mean age 9 years) who had shown the "best" response to diet manipulation in Phase I. Each child served as his own control and was challenged with specified amounts of placebo and artificial color containing food…

  15. Comparison of biatrial and left atrial radiofrequency ablation in patients with heart valves diseases

    Directory of Open Access Journals (Sweden)

    А. В. Богачев-прокофьев

    2015-10-01

    Full Text Available We analysed results of left atrial and biatrial anatomic scheme of radiofrequency (RF ablation of the atria in patients with valvular heart. From 2007 to 2011, RF ablation procedure performed 283 patients with atrial fibrillation and heart valve disease. Patients were divided into two groups - group I performed a complete circuit biatrial procedure (procedure maze IV - 131 patients, in group II only ablation of the left atrium -152 patients. Most of the patients had long-term persistent AF. The main problem of early postoperative period is dysfunction of pacemaker complex, which observed in 64.9% and 50.7% patients for group I and II, respectively (p = 0.031. Permanent dysfunction of pacemaker complex required implantation of permanent pacemaker (9.2% and 4.6% of cases for group I and II, respectively, p = 0,023. Predictors of dysfunction of the pacemaker complex were biatrial execution method and duration of AF. Freedom from AF and AT during 36 months after surgery was 80.4% for patients in group I and 78.5% for patients in group II, with no statistically significant difference (log-rank test, p = 0.621. Atrial transport function has not revealed that the active fraction of the right atrium was 29.8% higher than in group II in the early postoperative phase and by 17.9% in the long term, with no difference between groups for the left atrium has been received.

  16. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  17. Searching Neutrinoless Double Beta Decay with GERDA Phase II

    Science.gov (United States)

    Agostini, M.; Bakalyarov, A. M.; Balata, M.; Barabanov, I.; Baudis, L.; Bauer, C.; Bellotti, E.; Belogurov, S.; Bettini, A.; Bezrukov, L.; Bode, T.; Brudanin, V.; Brugnera, R.; Caldwell, A.; Cattadori, C.; Chernogorov, A.; Comellato, T.; D’Andrea, V.; Demidova, E. V.; di Marco, N.; Domula, A.; Doroshkevich, E.; Egorov, V.; Falkenstein, R.; Gangapshev, A.; Garfagnini, A.; Giordano, M.; Gooch, C.; Grabmayr, P.; Gurentsov, V.; Gusev, K.; Hahne, C.; Hakenmüller, J.; Hegai, A.; Heisel, M.; Hemmer, S.; Hiller, R.; Hofmann, W.; Holl, P.; Hult, M.; Inzhechik, L. V.; Ioannucci, L.; Csáthy, J. Janicskó; Jochum, J.; Junker, M.; Kazalov, V.; Kermaidic, Y.; Kihm, T.; Kirpichnikov, I. V.; Kirsch, A.; Kish, A.; Klimenko, A.; Kneißl, R.; Knöpfle, K. T.; Kochetov, O.; Kornoukhov, V. N.; Kuzminov, V. V.; Laubenstein, M.; Lazzaro, A.; Lindner, M.; Lippi, I.; Lubashevskiy, A.; Lubsandorzhiev, B.; Lutter, G.; Macolino, C.; Majorovits, B.; Maneschg, W.; Marissens, G.; Miloradovic, M.; Mingazheva, R.; Misiaszek, M.; Moseev, P.; Nemchenok, I.; Nisi, S.; Panas, K.; Pandola, L.; Pelczar, K.; Pullia, A.; Ransom, C.; Reissfelder, M.; Riboldi, S.; Rumyantseva, N.; Sada, C.; Sala, E.; Salamida, F.; Schmitt, C.; Schneider, B.; Schreiner, J.; Schulz, O.; Schweisshelm, B.; Schwingenheuer, B.; Schönert, S.; Schütz, A.-K.; Seitz, H.; Selivanenko, O.; Shevchik, E.; Shirchenko, M.; Simgen, H.; Smolnikov, A.; Stanco, L.; Vanhoefer, L.; Vasenko, A. A.; Veresnikova, A.; von Sturm, K.; Wagner, V.; Wegmann, A.; Wester, T.; Wiesinger, C.; Wojcik, M.; Yanovich, E.; Zhitnikov, I.; Zhukov, S. V.; Zinatulina, D.; Zschocke, A.; Zsigmond, A. J.; Zuber, K.; Zuzel, G.

    An observation of neutrinoless double beta (0νββ) decay would allow to shed light onto the nature of neutrinos. GERDA (GERmanium Detector Array) aims to discover this process in a background-free search using 76Ge. The experiment is located at the Laboratori Nazionali del Gran Sasso (LNGS) of the Istituto Nazionale di Fisica Nucleare (INFN) in Italy. Bare, isotopically enriched, high purity germanium detectors are operated in liquid argon. GERDA follows a staged approach. In Phase II 35.6 kg of enriched germanium detectors are operated since December 2015. The application of active background rejection methods, such as a liquid argon scintillation light read-out and pulse shape discrimination of germanium detector signals, allows to reduce the background index to the intended level of 10‑3 cts/(keVṡkgṡyr). No evidence for the 0νββ decay has been found in 23.2 kgṡyr of Phase II data, and together with data from Phase I the up-to-date most stringent half-life limit for this process in 76Ge has been established, at a median sensitivity of 5.8ṡ1025yr the 90% C.L. lower limit is 8.0ṡ1025yr.

  18. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p tricuspid valve regurgitation (mean 2.33 vs 1.3, p tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first

  19. Traumatic tricuspid valve insufficiency. Experience in thirteen patients.

    Science.gov (United States)

    van Son, J A; Danielson, G K; Schaff, H V; Miller, F A

    1994-11-01

    From 1964 through June 1993, thirteen patients with traumatic tricuspid insufficiency were treated surgically; all were male, and the ages ranged from 17 to 64 years (median 39 years). The condition was associated with blunt chest trauma in all patients: motor vehicle accidents in twelve and an explosion of a tank of compressed air in one. The median duration between trauma and operation was 17 years (range 1 month to 37 years). Preoperatively, six patients were in sinus rhythm and seven were in atrial fibrillation. At operation, the right ventricular function appeared moderately to severely depressed in twelve patients. In twelve patients, the anterior leaflet was flail because of chordal rupture (n = 9), rupture of anterior papillary muscle (n = 3), or tear in the anterior leaflet (n = 1). In one patient, the septal leaflet was missing and in another it was retracted and adherent to the ventricular septum. In five patients the tricuspid valve was repaired and in eight it was replaced. In seven patients in the latter group, the chordae, papillary muscles, and/or tricuspid valve leaflet(s) were found to be in a contracted and atrophic state, precluding repair. No early or late deaths occurred. At follow-up extending to 26 years (median 12 years), 12 patients are in New York Heart Association class I and one patient is in class II. Nine patients were in sinus rhythm and four were in atrial fibrillation. Although our experience indicates that good functional results can still be achieved many years after the onset of traumatic tricuspid valve insufficiency, earlier diagnosis and surgical treatment should increase the feasibility of tricuspid valve insufficiency, earlier diagnosis and surgical treatment should increase the feasibility of tricuspid valve repair, prevent progressive deterioration of right ventricular function, and increase the possibility of maintaining late sinus rhythm in a greater number of patients.

  20. PWR steam generator chemical cleaning. Phase II. Final report

    International Nuclear Information System (INIS)

    1980-01-01

    Two techniques believed capable of chemically dissolving the corrosion products in the annuli between tubes and support plates were developed in laboratory work in Phase I of this project and were pilot tested in Indian Point Unit No. 1 steam generators. In Phase II, one of the techniques was shown to be inadequate on an actual sample taken from an Indian Point Unit No. 2 steam generator. The other technique was modified slightly, and it was demonstrated that the tube/support plate annulus could be chemically cleaned effectively

  1. The SafeBoosC Phase II Randomised Clinical Trial

    DEFF Research Database (Denmark)

    Pellicer, Adelina; Greisen, Gorm; Benders, Manon

    2013-01-01

    Near-infrared spectroscopy-derived regional tissue oxygen saturation of haemoglobin (rStO2) reflects venous oxygen saturation. If cerebral metabolism is stable, rStO2 can be used as an estimate of cerebral oxygen delivery. The SafeBoosC phase II randomised clinical trial hypothesises that the bur...

  2. Tomographic PIV behind a prosthetic heart valve

    Science.gov (United States)

    Hasler, D.; Landolt, A.; Obrist, D.

    2016-05-01

    The instantaneous three-dimensional velocity field past a bioprosthetic heart valve was measured using tomographic particle image velocimetry. Two digital cameras were used together with a mirror setup to record PIV images from four different angles. Measurements were conducted in a transparent silicone phantom with a simplified geometry of the aortic root. The refraction indices of the silicone phantom and the working fluid were matched to minimize optical distortion from the flow field to the cameras. The silicone phantom of the aorta was integrated in a flow loop driven by a piston pump. Measurements were conducted for steady and pulsatile flow conditions. Results of the instantaneous, ensemble and phase-averaged flow field are presented. The three-dimensional velocity field reveals a flow topology, which can be related to features of the aortic valve prosthesis.

  3. Development of cryogenic free-piston reciprocating expander utilizing phase controller

    Energy Technology Data Exchange (ETDEWEB)

    Cha, Jeong Min; Park, Ji Ho; Kim, Kyung Joong; Jeong, Sang Kwon [Korea Advanced Institute of Science and Technology, Daejeon (Korea, Republic of)

    2016-06-15

    A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander.

  4. Development of cryogenic free-piston reciprocating expander utilizing phase controller

    International Nuclear Information System (INIS)

    Cha, Jeong Min; Park, Ji Ho; Kim, Kyung Joong; Jeong, Sang Kwon

    2016-01-01

    A free-piston reciprocating expander is a device which operates without any mechanical linkage to a stationary part. Since the motion of the floating piston is only controlled by the pressure difference at two ends of the piston, this kind of expander may indispensably require a sophisticated active control system equipped with multiple valves and reservoirs. In this paper, we have suggested a novel design that can further reduce complexity of the previously developed cryogenic free-piston expander configuration. It is a simple replacement of both multiple valves and reservoirs by a combination of an orifice valve and a reservoir. The functional characteristic of the integrated orifice-reservoir configuration is similar to that of a phase controller applied in a pulse tube refrigerator so that we designate the one as a phase controller. Depending on the orifice valve size in the phase controller, the different PV work which affects the expander performance is generated. The numerical model of this unique free-piston reciprocating expander utilizing a phase controller is established to understand and analyze quantitatively the performance variation of the expander under different valve timing and orifice valve size. The room temperature experiments are carried out to examine the performance of this newly developed cryogenic expander

  5. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  6. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  7. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  8. An FPGA-based trigger for the phase II of the MEG experiment

    Energy Technology Data Exchange (ETDEWEB)

    Baldini, A. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Bemporad, C.; Cei, F. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Dipartimento di Fisica, Università di Pisa (Italy); Galli, L.; Grassi, M.; Morsani, F. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Nicolò, D., E-mail: donato.nicolo@pi.infn.it [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Dipartimento di Fisica, Università di Pisa (Italy); Ritt, S. [Paul Scherrer Institut, Villigen AG (Switzerland); Venturini, M. [Istituto Nazionale di Fisica Nucleare, Pisa (Italy); Scuola Normale Superiore, Pisa (Italy)

    2016-07-11

    For the phase II of MEG, we are going to develop a combined trigger and DAQ system. Here we focus on the former side, which operates an on-line reconstruction of detector signals and event selection within 450 μs from event occurrence. Trigger concentrator boards (TCB) are under development to gather data from different crates, each connected to a set of detector channels, to accomplish higher-level algorithms to issue a trigger in the case of a candidate signal event. We describe the major features of the new system, in comparison with phase I, as well as its performances in terms of selection efficiency and background rejection. - Highlights: • A new, two-level trigger scheme for the phase-II of the MEG experiment is presented. • Improvements with respect to phase-I are underlined. • The role of detector upgrades and the use of a new generation of FPGA as well are emphasized.

  9. Finite Element Models for Electron Beam Freeform Fabrication Process, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II proposal offers to develop a comprehensive computer simulation methodology based on the finite element method for...

  10. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  11. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  12. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  13. Identification of phase-II metabolites of flavonoids by liquid chromatography-ion-mobility spectrometry-mass spectrometry.

    Science.gov (United States)

    Chalet, Clément; Hollebrands, Boudewijn; Janssen, Hans-Gerd; Augustijns, Patrick; Duchateau, Guus

    2018-01-01

    Flavonoids are a class of natural compounds with a broad range of potentially beneficial health properties. They are subjected to an extensive intestinal phase-II metabolism, i.e., conjugation to glucuronic acid, sulfate, and methyl groups. Flavonoids and their metabolites can interact with drug transporters and thus interfere with drug absorption, causing food-drug interactions. The site of metabolism plays a key role in the activity, but the identification of the various metabolites remains a challenge. Here, we developed an analytical method to identify the phase-II metabolites of structurally similar flavonoids. We used liquid chromatography-ion-mobility spectrometry-mass spectrometry (LC-IMS-MS) analysis to identify phase-II metabolites of flavonols, flavones, and catechins produced by HT29 cells. We showed that IMS could bring valuable structural information on the different positional isomers of the flavonols and flavones. The position of the glucuronide moiety had a strong influence on the collision cross section (CCS) of the metabolites, with only minor contribution of hydroxyl and methyl moieties. For the catechins, fragmentation data obtained from MS/MS analysis appeared more useful than IMS to determine the structure of the metabolites, mostly due to the high number of metabolites formed. Nevertheless, CCS information as a molecular fingerprint proved to be useful to identify peaks from complex mixtures. LC-IMS-MS thus appears as a valuable tool for the identification of phase-II metabolites of flavonoids. Graphical abstract Structural identification of phase-II metabolites of flavonoids using LC-IMS-MS.

  14. Comparison of magnetic resonance imaging and Laser Doppler Anemometry velocity measurements downstream of replacement heart valves: implications for in vivo assessment of prosthetic valve function.

    Science.gov (United States)

    Fontaine, A A; Heinrich, R S; Walker, P G; Pedersen, E M; Scheidegger, M B; Boesiger, P; Walton, S P; Yoganathan, A P

    1996-01-01

    The non-invasive, in-vivo assessment of prosthetic valve function is compromised by the lack of accurate measurements of the transvalvular flow fields or hemodynamics by current techniques. Short echo time magnetic resonance imaging (MRI) may provide a method for the non-invasive, in vivo assessment of prosthetic valve function by accurately measuring changes in the transvalvular flow fields associated with normal and dysfunctional prosthetic valves. The objectives of these in vitro experiments were to investigate the potential for using MRI as a tool to measure the complex flow fields distal to replacement heart valves, and to assess the accuracy of MRI velocity measurements by comparison with Laser Doppler Anemometry (LDA), a gold standard. The velocity fields downstream of tilting disc, bileaflet, ball and cage, and pericardial tissue valves were measured using both three-component LDA and MRI phase velocity encoding under a steady flow rate of 22.8 l/min, simulating peak systolic flow. The valves were tested under normal and stenotic conditions to assess the MRI capabilities under a wide range of local flow conditions, velocities and turbulence levels. A new short echo time MRI technique (FAcE), which allowed velocity measurements in stenotic jets with high turbulence, was tested. Good overall agreement was obtained between the MRI velocity measurements and the LDA data. The MRI velocity measurements adequately reproduced the spatial structure of the flow fields. In most cases peak velocities were accurately measured to within 15%. The results indicate that the FAcE MRI method has the potential to be used as a diagnostic tool to assess prosthetic valve function.

  15. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  16. Quality of reporting in oncology phase II trials: A 5-year assessment through systematic review.

    Science.gov (United States)

    Langrand-Escure, Julien; Rivoirard, Romain; Oriol, Mathieu; Tinquaut, Fabien; Rancoule, Chloé; Chauvin, Frank; Magné, Nicolas; Bourmaud, Aurélie

    2017-01-01

    Phase II clinical trials are a cornerstone of the development in experimental treatments They work as a "filter" for phase III trials confirmation. Surprisingly the attrition ratio in Phase III trials in oncology is significantly higher than in any other medical specialty. This suggests phase II trials in oncology fail to achieve their goal. Objective The present study aims at estimating the quality of reporting in published oncology phase II clinical trials. A literature review was conducted among all phase II and phase II/III clinical trials published during a 5-year period (2010-2015). All articles electronically published by three randomly-selected oncology journals with Impact-Factors>4 were included: Journal of Clinical Oncology, Annals of Oncology and British Journal of Cancer. Quality of reporting was assessed using the Key Methodological Score. 557 articles were included. 315 trials were single-arm studies (56.6%), 193 (34.6%) were randomized and 49 (8.8%) were non-randomized multiple-arm studies. The Methodological Score was equal to 0 (lowest level), 1, 2, 3 (highest level) respectively for 22 (3.9%), 119 (21.4%), 270 (48.5%) and 146 (26.2%) articles. The primary end point is almost systematically reported (90.5%), while sample size calculation is missing in 66% of the articles. 3 variables were independently associated with reporting of a high standard: presence of statistical design (p-value <0.001), multicenter trial (p-value = 0.012), per-protocol analysis (p-value <0.001). Screening was mainly performed by a sole author. The Key Methodological Score was based on only 3 items, making grey zones difficult to translate. This literature review highlights the existence of gaps concerning the quality of reporting. It therefore raised the question of the suitability of the methodology as well as the quality of these trials, reporting being incomplete in the corresponding articles.

  17. Advanced materials for future Phase II LHC collimators

    CERN Document Server

    Dallocchio, A; Arnau Izquierdo, G; Artoos, K

    2009-01-01

    Phase I collimators, equipped with Carbon-Carbon jaws, effectively met specifications for the early phase of LHC operation. However, the choice of carbon-based materials is expected to limit the nominal beam intensity mainly because of the high RF impedance and limited efficiency of the collimators. Moreover, C/C may be degraded by high radiation doses. To overcome these limitations, new Phase II secondary collimators will complement the existing system. Their extremely challenging requirements impose a thorough material investigation effort aiming at identifying novel materials combining very diverse properties. Relevant figures of merit have been identified to classify materials: Metal-diamonds composites look a promising choice as they combine good thermal, structural and stability properties. Molybdenum is interesting for its good thermal stability. Ceramics with non-conventional RF performances are also being evaluated. The challenges posed by the development and industrialization of these materials are ...

  18. How competitive are EU electricity markets? An assessment of ETS Phase II

    International Nuclear Information System (INIS)

    Castagneto-Gissey, Giorgio

    2014-01-01

    This paper studies the interactions between electricity and carbon allowance prices in the year-ahead energy markets of France, Germany, United Kingdom and the Nordic countries, during Phase II of the EU ETS. VAR and Granger-causality methods are used to analyze causal interfaces, whereas the volatility of electricity prices is studied with basic and asymmetric AR-GARCH models. Among the main results, the marginal rate at which carbon prices feed into electricity prices is shown to be ca. 135% in the EEX and Nord Pool markets, where electricity and carbon prices display bidirectional causality, and 109% in the UK. Therefore, generators in these markets internalized the cost of freely allotted emission allowances into their electricity prices considerably more than the proportionate increase in costs justified by effective carbon intensity. Moreover, electricity prices in France are found to Granger-cause the carbon price. This study also shows how European electricity prices are deeply linked to coal prices among other factors, both in terms of levels and volatility, regardless of the underlying fuel mix, and that coal was marginally more profitable than gas for electricity generation. EU policies aimed at increasing the carbon price are likely to be crucial in limiting the externalities involved in the transition to a low-carbon system. - Highlights: • The interactions between electricity and carbon prices during Phase II are investigated. • This work also studies the determinants of EU electricity price levels and volatilities. • Nord Pool, APX UK and EEX carbon cost pass-through rates emphasize low electricity market competitiveness. • Powernext electricity prices Granger-cause the Phase II carbon price. • Coal was marginally more profitable than gas during Phase II

  19. Fiber Coupled Pulse Shaper for Sub-Nanosecond Pulse Lidar, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II effort will develop an all-diode laser and fiber optic based, single frequency, sub-nanosecond pulsed laser source...

  20. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  1. On discharge from poppet valves: effects of pressure and system dynamics

    Science.gov (United States)

    Winroth, P. M.; Ford, C. L.; Alfredsson, P. H.

    2018-02-01

    Simplified flow models are commonly used to design and optimize internal combustion engine systems. The exhaust valves and ports are modelled as straight pipe flows with a corresponding discharge coefficient. The discharge coefficient is usually determined from steady-flow experiments at low pressure ratios and at fixed valve lifts. The inherent assumptions are that the flow through the valve is insensitive to the pressure ratio and may be considered as quasi-steady. The present study challenges these two assumptions through experiments at varying pressure ratios and by comparing measurements of the discharge coefficient obtained under steady and dynamic conditions. Steady flow experiments were performed in a flow bench, whereas the dynamic measurements were performed on a pressurized, 2 l, fixed volume cylinder with one or two moving valves. In the latter experiments an initial pressure (in the range 300-500 kPa) was established whereafter the valve(s) was opened with a lift profile corresponding to different equivalent engine speeds (in the range 800-1350 rpm). The experiments were only concerned with the blowdown phase, i.e. the initial part of the exhaustion process since no piston was simulated. The results show that the process is neither pressure-ratio independent nor quasi-steady. A measure of the "steadiness" has been defined, relating the relative change in the open flow area of the valve to the relative change of flow conditions in the cylinder, a measure that indicates if the process can be regarded as quasi-steady or not.

  2. Percutaneous implantation of the first repositionable aortic valve prosthesis in a patient with severe aortic stenosis.

    Science.gov (United States)

    Buellesfeld, Lutz; Gerckens, Ulrich; Grube, Eberhard

    2008-04-01

    Percutaneous aortic valve replacement is a new less-invasive alternative for high-risk surgical candidates with aortic stenosis. However, the clinical experience is still limited, and the currently available 'first-generation devices' revealed technical shortcomings, such as lack of repositionability and presence of paravalvular leakages. We report the first-in-man experience with the new self-expanding Lotus Valve prosthesis composed of a nitinol frame with implemented bovine pericardial leaflets which is designed to address these issues, being repositionable and covered by a flexible membrane to seal paravalvular gaps. We implanted this prosthesis in a 93-year old patient presenting with severe symptomatic aortic stenosis (valve area: 0.6 cm(2)). Surgical valve replacement had been declined due to comorbidities. We used a retrograde approach for insertion of the 21-French Lotus catheter loaded with the valve prosthesis via surgical cut-down to the external iliac artery. Positioning of the valve was guided by transesophageal echo and supra-aortic angiograms. The prosthesis was successfully inserted and deployed within the calcified native valve. Echocardiography immediately after device deployment showed a significant reduction of the transaortic mean pressure gradient (32 to 9 mmHg; final valve area 1.7 cm(2)) without evidence of residual aortic regurgitation. The postprocedural clinical status improved from NYHA-IV to NYHA-II. These results remained unchanged up to the 3 month follow-up. Successful percutaneous aortic valve replacement can be performed using the new self-expanding and repositionable Lotus valve for treatment of high-risk patients with aortic valve stenosis. Further studies are mandatory to assess device safety and efficacy in larger patient populations. Copyright 2008 Wiley-Liss, Inc.

  3. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  4. Numerical simulation and analysis of ball valve three-dimensional flow based on CFD

    International Nuclear Information System (INIS)

    Zhang, S C; Zhang, Y L; Fang, Z M

    2012-01-01

    The new rotor oil-gas mixture pump that added ball valves in its export is a kind of innovative products, which can better adapt to the oil and gas mixed condition. In order to explore the rule of flow field in the export ball valve of new rotor oil-gas mixture pump, established the 3 d model of ball valve flow field was established. Using the FLUENT software, combining the standard k-ε turbulent model with multiphase flow technology and adopting the SIMPLE algorithm to simulate the 3 d gas-liquid two phase flow field in export ball valve of new rotor oil-gas mixture pump. In the different conditions that the volume of gas rate was 25%, 50%, 75%, through analyzing the velocity field, stress field and the distribution of the liquid and gas with the ball valve open height respectively at 3mm, 5mm, 7mm. Discussed how open height and different volume of gas rate to influence the field in export ball valve in the process of gas-liquid mixing was discussed. The simulation results showed that the greater the open height, the smaller the difference pressure of ball valve; the gap velocity decreasing with the open height increasing. The gas is mainly distributed in the vicinity of the valve ball in the process of gas-liquid mixing. The gas liquid ratio has a little effect on the gap velocity in the same open height. The results showed the flow field forms in the ball valve directly, to a certain degree, it had released the rules of gas-liquid flow in the valve and provided the theoretical guidance for design and optimization of the new rotor oil-gas mixture pump export ball valve.

  5. An Instrument for Inspecting Aspheric Optical Surfaces and Components, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This is a Phase II SBIR proposal to develop an extremely versatile optical inspection tool for aspheric optical components and optics that are not easily inspected...

  6. Prevention of water hammers behind fast acting shut-off valves

    International Nuclear Information System (INIS)

    Dudlik, A.; Schlueter, S.; Prasser, H.M.

    1999-01-01

    Shut-off valves are often applied for a quick safety shut-down of pipelines for dangerous liquids. When the valve is suddenly closed at a certain flow rate, the pressure behind the valve decreases due to the momentum of the liquid. This leads to an evaporation and to a formation of a cavitation bubble if the resulting minimum pressure becomes lower than the saturation pressure at the given temperature. This type of water hammer was studied at a test facility of Fraunhofer UMSICHT in Oberhausen. The task of FZR was the development of an adequate two-phase flow instrumentation to visualise the cavitation phenomenon. During the project unique digital movie sequences of appearing and condensing cavitation bubbles were recorded, that gave valuable insights into the transient process. In the result, a new method was found to prevent the collapse of the cavitation bubbles and to avoid the corresponding pressure peaks. (orig.)

  7. 2-Phase NSGA II: An Optimized Reward and Risk Measurements Algorithm in Portfolio Optimization

    Directory of Open Access Journals (Sweden)

    Seyedeh Elham Eftekharian

    2017-11-01

    Full Text Available Portfolio optimization is a serious challenge for financial engineering and has pulled down special attention among investors. It has two objectives: to maximize the reward that is calculated by expected return and to minimize the risk. Variance has been considered as a risk measure. There are many constraints in the world that ultimately lead to a non–convex search space such as cardinality constraint. In conclusion, parametric quadratic programming could not be applied and it seems essential to apply multi-objective evolutionary algorithm (MOEA. In this paper, a new efficient multi-objective portfolio optimization algorithm called 2-phase NSGA II algorithm is developed and the results of this algorithm are compared with the NSGA II algorithm. It was found that 2-phase NSGA II significantly outperformed NSGA II algorithm.

  8. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  9. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  10. Differential roles of phase I and phase II enzymes in 3,4-methylendioxymethamphetamine-induced cytotoxicity.

    NARCIS (Netherlands)

    Antolino Lobo, I.; Meulenbelt, J.; Nijmeijer, S.M.; Scherpenisse, P.; van den Berg, M.; van Duursen, M.B.M.

    2010-01-01

    Metabolism plays an important role in the toxic effects caused by 3,4-methylenedioxymethamphetamine (MDMA). Most research has focused on the involvement of CYP2D6 enzyme in MDMA bioactivation, and less is known about the contribution of other cytochrome P450 (P450) and phase II metabolism. In this

  11. Phased Retrofits in Existing Homes in Florida Phase II: Shallow Plus Retrofits

    Energy Technology Data Exchange (ETDEWEB)

    Sutherland, K. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Parker, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Martin, E. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Chasar, D. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States); Amos, B. [Building America Partnership for Improved Residential Construction, Cocoa, FL (United States)

    2016-02-03

    The BAPIRC team and Florida Power and Light (FPL) electric utility pursued a pilot phased energy-efficiency retrofit program in Florida by creating detailed data on the energy and economic performance of two levels of retrofit - simple and deep. For this Phased Deep Retrofit (PDR) project, a total of 56 homes spread across the utility partner's territory in east central Florida, southeast Florida, and southwest Florida were instrumented between August 2012 and January 2013, and received simple pass-through retrofit measures during the period of March 2013 - June 2013. Ten of these homes received a deeper package of retrofits during August 2013 - December 2013. A full account of Phase I of this project, including detailed home details and characterization, is found in Parker et al, 2015 (currently in draft). Phase II of this project, which is the focus of this report, applied the following additional retrofit measures to select homes that received a shallow retrofit in Phase I: a) Supplemental mini-split heat pump (MSHP) (6 homes); b) Ducted and space coupled Heat Pump Water Heater (8 homes); c) Exterior insulation finish system (EIFS) (1 homes); d) Window retrofit (3 homes); e) Smart thermostat (21 homes: 19 NESTs; 2 Lyrics); f) Heat pump clothes dryer (8 homes); g) Variable speed pool pump (5 homes).

  12. Identification of critical zones in the flow through prosthetic heart valves

    Science.gov (United States)

    Lopez, A.; Ledesma, R.; Zenit, R.; Pulos, G.

    2008-11-01

    The hemodynamic properties of prosthetic heart valves can cause blood damage and platelet activation due to the non- physiological flow patterns. Blood recirculation and elevated shear stresses are believed to be responsible for these complications. The objective of this study is to identify and quantify the conditions for which recirculation and high stress zones appear. We have performed a comparative study between a mechanical monoleaflet and biological valve. In order to generate the flow conditions to test the prosthesis, we have built a hydraulic circuit which reproduces the human systemic circulation, on the basis of the Windkessel model. This model is based on an electrical analogy which consists of an arterial resistance and compliance. Using PIV 3D- Stereo measurements, taken downstream from the prosthetic heart valves, we have reconstructed the full phase-averaged tridimensional velocity field. Preliminary results show that critical zones are more prominent in mechanical prosthesis, indicating that valves made with bio-materials are less likely to produce blood trauma. This is in accordance with what is generally found in the literature.

  13. The Impact of Fluid Inertia on In Vivo Estimation of Mitral Valve Leaflet Constitutive Properties and Mechanics.

    Science.gov (United States)

    Bark, David L; Dasi, Lakshmi P

    2016-05-01

    We examine the influence of the added mass effect (fluid inertia) on mitral valve leaflet stress during isovolumetric phases. To study this effect, oscillating flow is applied to a flexible membrane at various frequencies to control inertia. Resulting membrane strain is calculated through a three-dimensional reconstruction of markers from stereo images. To investigate the effect in vivo, the analysis is repeated on a published dataset for an ovine mitral valve (Journal of Biomechanics 42(16): 2697-2701). The membrane experiment demonstrates that the relationship between pressure and strain must be corrected with a fluid inertia term if the ratio of inertia to pressure differential approaches 1. In the mitral valve, this ratio reaches 0.7 during isovolumetric contraction for an acceleration of 6 m/s(2). Acceleration is reduced by 72% during isovolumetric relaxation. Fluid acceleration also varies along the leaflet during isovolumetric phases, resulting in spatial variations in stress. These results demonstrate that fluid inertia may be the source of the temporally and spatially varying stiffness measurements previously seen through inverse finite element analysis of in vivo data during isovolumetric phases. This study demonstrates that there is a need to account for added mass effects when analyzing in vivo constitutive relationships of heart valves.

  14. Caelyx (TM) in malignant mesothelioma : A phase II EORTC study

    NARCIS (Netherlands)

    Baas, P; van Meerbeeck, J; Groen, H; Schouwink, H; Burgers, S; Daamen, S; Giaccone, G

    Background: The use of doxorubicin has shown some activity in malignant mesothelioma but prolonged administration is hampered by cardiotoxicity. Caelyx(TM), a new liposomal and pegylated form of doxorubicin has shown a better pharmacokinetic and toxic profile then doxorubicin. In a phase II study,

  15. Cellular Changes during Renal Failure-Induced Inflammatory Aortic Valve Disease.

    Directory of Open Access Journals (Sweden)

    Mony Shuvy

    Full Text Available Aortic valve calcification (AVC secondary to renal failure (RF is an inflammation-regulated process, but its pathogenesis remains unknown. We sought to assess the cellular processes that are involved in the early phases of aortic valve disease using a unique animal model of RF-associated AVC.Aortic valves were obtained from rats that were fed a uremia-inducing diet exclusively for 2, 3, 4, 5, and 6 weeks as well as from controls. Pathological examination of the valves included histological characterization, von Kossa staining, and antigen expression analyses.After 2 weeks, we noted a significant increase in urea and creatinine levels, reflecting RF. RF parameters exacerbated until the Week 5 and plateaued. Whereas no histological changes or calcification was observed in the valves of any study group, macrophage accumulation became apparent as early as 2 weeks after the diet was started and rose after 3 weeks. By western blot, osteoblast markers were expressed after 2 weeks on the diet and decreased after 6 weeks. Collagen 3 was up-regulated after 3 weeks, plateauing at 4 weeks, whereas collagen 1 levels peaked at 2 and 4 weeks. Fibronectin levels increased gradually until Week 5 and decreased at 6 weeks. We observed early activation of the ERK pathway, whereas other pathways remained unchanged.We concluded that RF induces dramatic changes at the cellular level, including macrophage accumulation, activation of cell signaling pathway and extracellular matrix modification. These changes precede valve calcification and may increase propensity for calcification, and have to be investigated further.

  16. Recommendations for main line block valves installation in gas pipelines; Recomendacoes para instalacao de valvulas de bloqueio de linha tronco em gasodutos

    Energy Technology Data Exchange (ETDEWEB)

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Oliveira, Valeriano Duque de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Cases of gas pipelines block valves and its pneumatic actuators presenting problems during the final pipeline commissioning and pre-operation phases, like internal leaks, leaking to the atmosphere, pneumatic circuit defects caused by water and debris, are nearly common. The majority can be avoided if a series of measuring are to be planned and implemented, as well as if an adequate planning of commissioning operations and line gasification, valves and actuators, are to be applied. This paper shows the practical experience in the construction and commissioning of valves and its actuators in the Bolivia-Brazil gas pipeline, which, in the first construction phase had a series of problems. After the diagnosis a set of procedures was implemented in the secondary construction phase, resulting in insignificant problems detected. All measures and procedures taken in the planning process, as well as additional aspects related to the main line valve design, its by-passes and supports, are demonstrated. (author)

  17. Hypertensive phase and early complications after Ahmed glaucoma valve implantation with intraoperative subtenon triamcinolone acetonide

    Directory of Open Access Journals (Sweden)

    Turalba AV

    2014-07-01

    Full Text Available Angela V Turalba,1,2 Louis R Pasquale1,2 1Department of Ophthalmology, Massachusetts Eye and Ear Infirmary, Boston, MA, USA; 2Department of Ophthalmology, Harvard Medical School, Boston, MA, USA Objective: To evaluate intraoperative subtenon triamcinolone acetonide (TA as an adjunct to Ahmed glaucoma valve (AGV implantation. Design: Retrospective comparative case series. Participants: Forty-two consecutive cases of uncontrolled glaucoma undergoing AGV implantation: 19 eyes receiving intraoperative subtenon TA and 23 eyes that did not receive TA.Methods: A retrospective chart review was performed on consecutive pseudophakic adult patients with uncontrolled glaucoma undergoing AGV with and without intraoperative subtenon TA injection by a single surgeon. Clinical data were collected from 42 eyes and analyzed for the first 6 months after surgery.Main outcome measures: Primary outcomes included intraocular pressure (IOP and number of glaucoma medications prior to and after AGV implantation. The hypertensive phase (HP was defined as an IOP measurement of greater than 21 mmHg (with or without medications during the 6-month postoperative period that was not a result of tube obstruction, retraction, or malfunction. Postoperative complications and visual acuity were analyzed as secondary outcome measures. Results: Five out of 19 (26% TA cases and 12 out of 23 (52% non-TA cases developed the HP (P=0.027. Mean IOP (14.2±4.6 in TA cases versus [vs] 14.7±5.0 mmHg in non-TA cases; P=0.78, and number of glaucoma medications needed (1.8±1.3 in TA cases vs 1.6±1.1 in the comparison group; P=0.65 were similar between both groups at 6 months. Although rates of serious complications did not differ between the groups (13% in the TA group vs 16% in the non-TA group, early tube erosion (n=1 and bacterial endophthalmitis (n=1 were noted with TA but not in the non-TA group.Conclusions: Subtenon TA injection during AGV implantation may decrease the

  18. Flow Test to Predict Early Hypotony and Hypertensive Phase After Ahmed Glaucoma Valve (AGV) Surgical Implantation.

    Science.gov (United States)

    Cheng, Jason; Beltran-Agullo, Laura; Buys, Yvonne M; Moss, Edward B; Gonzalez, Johanna; Trope, Graham E

    2016-06-01

    To assess the validity of a preimplantation flow test to predict early hypotony [intraocular pressure (IOP)≤5 mm Hg on 2 consecutive visits and hypertensive phase (HP) (IOP>21 mm Hg) after Ahmed Glaucoma Valve (AGV) implantation. Prospective interventional study on patients receiving an AGV. A preimplantation flow test using a gravity-driven reservoir and an open manometer was performed on all AGVs. Opening pressure (OP) and closing pressure (CP) were defined as the pressure at which fluid was seen to flow or stop flowing through the AGV, respectively. OP and CP were measured twice per AGV. Patients were followed for 12 weeks. In total, 20 eyes from 19 patients were enrolled. At 12 weeks the mean IOP decreased from 29.2±9.1 to 16.8±5.2 mm Hg (P<0.01). The mean AGV OP was 17.5±5.4 mm Hg and the mean CP was 6.7±2.3 mm Hg. Early (within 2 wk postoperative) HP occurred in 37% and hypotony in 16% of cases. An 18 mm Hg cutoff for the OP gave a sensitivity of 0.71, specificity of 0.83, positive predictive value of 0.71, and negative predictive value of 0.83 for predicting an early HP. A 7 mm Hg cutoff for the CP yielded a sensitivity of 1.0, specificity of 0.38, positive predictive value of 0.23, and negative predictive value of 1.0 for predicting hypotony. Preoperative OP and CP may predict early hypotony or HP and may be used as a guide as to which AGV valves to discard before implantation surgery.

  19. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  20. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  1. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  2. Two-dimensional FSI simulation of closing dynamics of a tilting disc mechanical heart valve.

    Science.gov (United States)

    Govindarajan, V; Udaykumar, H S; Herbertson, L H; Deutsch, S; Manning, K B; Chandran, K B

    2010-03-01

    The fluid dynamics during valve closure resulting in high shear flows and large residence times of particles has been implicated in platelet activation and thrombus formation in mechanical heart valves. Our previous studies with bi-leaflet valves have shown that large shear stresses induced in the gap between the leaflet edge and the valve housing results in relatively high platelet activation levels whereas flow between the leaflets results in shed vortices not conducive to platelet damage. In this study we compare the result of closing dynamics of a tilting disc valve with that of a bi-leaflet valve. The two-dimensional fluid-structure interaction analysis of a tilting disc valve closure mechanics is performed with a fixed grid Cartesian mesh flow solver with local mesh refinement, and a Lagrangian particle dynamic analysis for computation of potential for platelet activation. Throughout the simulation the flow remains in the laminar regime and the flow through the gap width is marked by the development of a shear layer which separates from the leaflet downstream of the valve. Zones of re-circulation are observed in the gap between the leaflet edge and the valve housing on the major orifice region of the tilting disc valve and are seen to be migrating towards the minor orifice region. Jet flow is observed at the minor orifice region and a vortex is formed which sheds in the direction of fluid motion as observed in experiments using PIV measurements. The activation parameter computed for the tilting disc valve, at the time of closure was found to be 2.7 times greater than that of the bi-leaflet mechanical valve and was found to be in the vicinity of the minor orifice region mainly due to the migration of vortical structures from the major to the minor orifice region during the leaflet rebound of the closing phase.

  3. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  4. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  5. Phase equilibrium measurements and the tuning behavior of new sII clathrate hydrates

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Woongchul; Park, Seongmin; Ro, Hyeyoon; Koh, Dong-Yeun; Seol, Jiwoong [Department of Chemical and Biomolecular Engineering (BK21 Program), KAIST, Daejeon 305-701 (Korea, Republic of); Lee, Huen, E-mail: h_lee@kaist.ac.kr [Department of Chemical and Biomolecular Engineering (BK21 Program), KAIST, Daejeon 305-701 (Korea, Republic of); Graduate School of EEWS, KAIST, Daejeon 305-701 (Korea, Republic of)

    2012-01-15

    Graphical abstract: Pyrrolidine and piperidine act as sII clathrate hydrate formers under methane gas. Highlights: > New sII clathrate hydrate formers were proposed: pyrrolidine and piperidine. > Formation of gas hydrate with methane as help gas was confirmed. > NMR, Raman, and XRD patterns were analyzed to identify the hydrate structures. > We measured (L + H + V) phase equilibrium with proposed hydrate formers. > Tuning phenomena increase gas storage in (pyrrolidine + CH{sub 4}) clathrate hydrates. - Abstract: We suggest two types of new amine-type sII formers: pyrrolidine and piperidine. These guest compounds fail to form clathrate hydrate structures with host water, but instead have to combine with light gaseous guest molecules (methane) for enclathration. First, two binary clathrate hydrates of (pyrrolidine + methane) and (piperidine + methane) were synthesized at various amine concentrations. {sup 13}C NMR and Raman analysis were done to identify the clathrate hydrate structure and guest distribution over sII-S and sII-L cages. XRD was also used to find the exact structure and corresponding cell parameters. At a dilute pyrrolidine concentration of less than 5.56 mol%, the tuning phenomenon is observed such that methane molecules surprisingly occupy sII-L cages. At the critical guest concentration of about 0.1 mol%, the cage occupancy ratio reaches the maximum of approximately 0.5. At very dilute guest concentration below 0.1 mol%, the methane molecules fail to occupy large cages on account of their rarefied distribution in the network. Direct-release experiments were performed to determine the actual guest compositions in the clathrate hydrate phases. Finally, we measured the clathrate hydrate phase equilibria of (pyrrolidine + methane) and (piperidine + methane).

  6. Phase equilibrium measurements and the tuning behavior of new sII clathrate hydrates

    International Nuclear Information System (INIS)

    Shin, Woongchul; Park, Seongmin; Ro, Hyeyoon; Koh, Dong-Yeun; Seol, Jiwoong; Lee, Huen

    2012-01-01

    Graphical abstract: Pyrrolidine and piperidine act as sII clathrate hydrate formers under methane gas. Highlights: → New sII clathrate hydrate formers were proposed: pyrrolidine and piperidine. → Formation of gas hydrate with methane as help gas was confirmed. → NMR, Raman, and XRD patterns were analyzed to identify the hydrate structures. → We measured (L + H + V) phase equilibrium with proposed hydrate formers. → Tuning phenomena increase gas storage in (pyrrolidine + CH 4 ) clathrate hydrates. - Abstract: We suggest two types of new amine-type sII formers: pyrrolidine and piperidine. These guest compounds fail to form clathrate hydrate structures with host water, but instead have to combine with light gaseous guest molecules (methane) for enclathration. First, two binary clathrate hydrates of (pyrrolidine + methane) and (piperidine + methane) were synthesized at various amine concentrations. 13 C NMR and Raman analysis were done to identify the clathrate hydrate structure and guest distribution over sII-S and sII-L cages. XRD was also used to find the exact structure and corresponding cell parameters. At a dilute pyrrolidine concentration of less than 5.56 mol%, the tuning phenomenon is observed such that methane molecules surprisingly occupy sII-L cages. At the critical guest concentration of about 0.1 mol%, the cage occupancy ratio reaches the maximum of approximately 0.5. At very dilute guest concentration below 0.1 mol%, the methane molecules fail to occupy large cages on account of their rarefied distribution in the network. Direct-release experiments were performed to determine the actual guest compositions in the clathrate hydrate phases. Finally, we measured the clathrate hydrate phase equilibria of (pyrrolidine + methane) and (piperidine + methane).

  7. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  8. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  9. An in vitro investigation of the retrograde flow fields of two bileaflet mechanical heart valves.

    Science.gov (United States)

    Ellis, J T; Healy, T M; Fontaine, A A; Weston, M W; Jarret, C A; Saxena, R; Yoganathan, A P

    1996-11-01

    Fluid stresses occurring in retrograde flow fields during valve closure may play a significant role in thrombogenesis. The squeeze flow and regurgitant jets can cause damage to formed blood elements due to high levels of turbulent shear stress. The aim of this study was to characterize in detail the spatial structure and temporal behavior of the retrograde flow fields of the St. Jude Medical and Medtronic Parallel bileaflet mechanical heart valves. Three-component, coincident laser Doppler anemometry (LDA) velocity measurements were obtained facilitating the determination of the full Reynolds stress tensor and the principal stresses in the valve flow fields. The experiments were performed in the Georgia Tech aortic flow chamber under physiologic pulsatile flow conditions. Data were collected over several hundred cardiac cycles for subsequent phase window averaging and generation of mean velocity and turbulence statistics over 20 ms intervals. A region approximately 8 mm x 10 mm was mapped 1.0 mm upstream of one hinge of each valve with an incremental resolution of 0.13-0.25 mm. Animation of the data allowed the visualization of the flow fields and a quantitative display of mean velocity and turbulent stress values. In the St. Jude Medical squeeze flow, the peak turbulent shear stress was 800 dynes/cm2 and the peak reverse velocity was 0.60 m/s. In the Medtronic Parallel squeeze flow, the peak turbulent shear stress was 1,000 dynes/cm2 and the peak velocity 0.70 m/s. The leakage jet fields of the two valves were very different: in the case of the St. Jude Medical valve, turbulent shear stresses reached 1,800 dynes/cm2 and peak jet velocity was 0.80 m/s; in the case of the Medtronic Parallel valve, turbulent shear stresses reached 3,690 dynes/cm2 and the peak jet velocity was 1.9 m/s. The retrograde flow fields of these two bileaflet mechanical heart valves appear to be design-dependent. The elevated turbulent shear stresses generated by both valve designs may

  10. Load-dependent extracellular matrix organization in atrioventricular heart valves: differences and similarities.

    Science.gov (United States)

    Alavi, S Hamed; Sinha, Aditi; Steward, Earl; Milliken, Jeffrey C; Kheradvar, Arash

    2015-07-15

    The extracellular matrix of the atrioventricular (AV) valves' leaflets has a key role in the ability of these valves to properly remodel in response to constantly varying physiological loads. While the loading on mitral and tricuspid valves is significantly different, no information is available on how collagen fibers change their orientation in response to these loads. This study delineates the effect of physiological loading on AV valves' leaflets microstructures using Second Harmonic Generation (SHG) microscopy. Fresh natural porcine tricuspid and mitral valves' leaflets (n = 12/valve type) were cut and prepared for the experiments. Histology and immunohistochemistry were performed to compare the microstructural differences between the valves. The specimens were imaged live during the relaxed, loading, and unloading phases using SHG microscopy. The images were analyzed with Fourier decomposition to mathematically seek changes in collagen fiber orientation. Despite the similarities in both AV valves as seen in the histology and immunohistochemistry data, the microstructural arrangement, especially the collagen fiber distribution and orientation in the stress-free condition, were found to be different. Uniaxial loading was dependent on the arrangement of the fibers in their relaxed mode, which led the fibers to reorient in-line with the load throughout the depth of the mitral leaflet but only to reorient in-line with the load in deeper layers of the tricuspid leaflet. Biaxial loading arranged the fibers in between the two principal axes of the stresses independently from their relaxed states. Unlike previous findings, this study concludes that the AV valves' three-dimensional extracellular fiber arrangement is significantly different in their stress-free and uniaxially loaded states; however, fiber rearrangement in response to the biaxial loading remains similar. Copyright © 2015 the American Physiological Society.

  11. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  12. F/H Area Effluent Treatment Facility. Phase II. CAC basic data

    International Nuclear Information System (INIS)

    Collins, W.W.; O'Leary, C.D.

    1984-01-01

    Project objectives and requirements are listed for both Phase I and II. Schedule is listed with startup targeted for 1989. Storage facilities will be provided for both chemical and radioactive effluents. 8 figs., 19 tabs

  13. Echocardiographic Evaluation of Hemodynamic Changes in Left-Sided Heart Valves in Pregnant Women With Valvular Heart Disease.

    Science.gov (United States)

    Samiei, Niloufar; Amirsardari, Mandana; Rezaei, Yousef; Parsaee, Mozhgan; Kashfi, Fahimeh; Hantoosh Zadeh, Sedigheh; Beikmohamadi, Somayeh; Fouladi, Masoumeh; Hosseini, Saeid; Peighambari, Mohammad Mehdi; Mohebbi, Ahmad

    2016-10-01

    Physiologic changes during pregnancy can deteriorate or improve patients' hemodynamic status in the setting of valvular heart disease. There are sparse data regarding the effect of pregnancy on valve hemodynamics in normal pregnant women with known valvular heart disease. In a prospective study from July 2014 to January 2016, a total of 52 normal pregnant women who had mitral stenosis, aortic stenosis, or a history of mitral valve or aortic valve replacements were assessed. All patients underwent echocardiographic examinations and hemodynamic parameters were measured for both the mitral valve and aortic valve at first, second, and third trimesters. The parameters included mean gradient, peak gradient, mean gradient/heart rate, peak gradient/heart rate, pressure halftime, dimensionless velocity index, and valve area. Although most hemodynamic parameters (i.e., mean gradient, peak gradient, mean gradient/heart rate, and peak gradient/heart rate) increased approximately 50% from first to second trimester and first to third trimester (p 0.05). The ratio of changes between trimesters for valve area and dimensionless velocity index were comparable. No clinical decompensations were observed except for 3 and 7 cases of deterioration to functional class II at second and third trimesters, respectively. In conclusion, during a full-term and uncomplicated pregnancy, mitral and aortic valve gradients increase without significant changes in valve area that are more marked between the second and first trimester than between the third and second trimester. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  15. Urban Integrated Industrial Cogeneration Systems Analysis. Phase II final report

    Energy Technology Data Exchange (ETDEWEB)

    1984-01-01

    Through the Urban Integrated Industrial Cogeneration Systems Analysis (UIICSA), the City of Chicago embarked upon an ambitious effort to identify the measure the overall industrial cogeneration market in the city and to evaluate in detail the most promising market opportunities. This report discusses the background of the work completed during Phase II of the UIICSA and presents the results of economic feasibility studies conducted for three potential cogeneration sites in Chicago. Phase II focused on the feasibility of cogeneration at the three most promising sites: the Stockyards and Calumet industrial areas, and the Ford City commercial/industrial complex. Each feasibility case study considered the energy load requirements of the existing facilities at the site and the potential for attracting and serving new growth in the area. Alternative fuels and technologies, and ownership and financing options were also incorporated into the case studies. Finally, site specific considerations such as development incentives, zoning and building code restrictions and environmental requirements were investigated.

  16. Thermally induced pressure locking of gate valves: A survey of valve bonnet pressurization rates

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Moore, W.E.

    1996-01-01

    Closed, water filled gate valves run the risk of becoming pressurized due to heat input from the environment or from adjacent connected piping. Thermal pressurization of gate valve bonnets may lead to the valves failing to open on demand and can even induce structural failure of valves. This paper presents an analytical prediction of the pressurization rate of a closed pressure vessel subject to uniform heating which may be considered as an upper bound to the pressurization rate that may occur in the field. Then actual valve experiences described in the literature are reviewed to determine the expected pressurization rate in existing hardware designs. A statistical approach is applied to reconcile the differing pressurization rates reported in the literature and determine a rate that can be applied in valve evaluations. The limitations of the reconciled rate are discussed

  17. MULTIFUNCTIONAL, SELF-HEALING HYBRIDSIL MATERIALS FOR EVA SPACE SUIT PRESSURE GARMENT SYSTEMS, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — A Phase II SBIR transition of NanoSonic's high flex HybridSil space suit bladder and glove materials will provide a pivotal funding bridge toward Phase III...

  18. Mortality Risk After Transcatheter Aortic Valve Implantation: Analysis of the Predictive Accuracy of the Transcatheter Valve Therapy Registry Risk Assessment Model.

    Science.gov (United States)

    Codner, Pablo; Malick, Waqas; Kouz, Remi; Patel, Amisha; Chen, Cheng-Han; Terre, Juan; Landes, Uri; Vahl, Torsten Peter; George, Isaac; Nazif, Tamim; Kirtane, Ajay J; Khalique, Omar K; Hahn, Rebecca T; Leon, Martin B; Kodali, Susheel

    2018-05-08

    Risk assessment tools currently used to predict mortality in transcatheter aortic valve implantation (TAVI) were designed for patients undergoing cardiac surgery. We aim to assess the accuracy of the TAVI dedicated American College of Cardiology / Transcatheter Valve Therapies (ACC/TVT) risk score in predicting mortality outcomes. Consecutive patients (n=1038) undergoing TAVI at a single institution from 2014 to 2016 were included. The ACC/TVT registry mortality risk score, the Society of Thoracic Surgeons - Patient Reported Outcomes (STS-PROM) score and the EuroSCORE II were calculated for all patients. In hospital and 30-day all-cause mortality rates were 1.3% and 2.9%, respectively. The ACC/TVT risk stratification tool scored higher for patients who died in-hospital than in those who survived the index hospitalization (6.4 ± 4.6 vs. 3.5 ± 1.6, p = 0.03; respectively). The ACC/TVT score showed a high level of discrimination, C-index for in-hospital mortality 0.74, 95% CI [0.59 - 0.88]. There were no significant differences between the performance of the ACC/TVT registry risk score, the EuroSCORE II and the STS-PROM for in hospital and 30-day mortality rates. The ACC/TVT registry risk model is a dedicated tool to aid in the prediction of in-hospital mortality risk after TAVI.

  19. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  20. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  1. Monolithic, High-Speed Fiber-Optic Switching Array for Lidar, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This NASA SBIR Phase II effort will develop a 1 x 10 prototype non-mechanical fiber optic switch for use with high power lasers. The proposed optical device is a...

  2. Development and production of nuclear valves. Forging and welding. Pt. 2

    International Nuclear Information System (INIS)

    Bernal Castro, J.B.; Perez, J.C.; Labonia, R.N.

    1987-01-01

    The first part of this work deals with the obtainment of the austenitic stainless steel DIN 1.4541 (AISI 321) stabilized titanium for Atucha II nuclear valves. The second part presented herein, continued with the development process and part of the production of the bodies' forging and valves leads. This development has been also carried out in the country and a detailed set up of the process with its corresponding Inspection and Assay Program was needed. The last part of this stage has been initiated at the welding process, so it was necessary to develop specific welding procedures to qualify them and use the equipment specially applied to this requirement. The set of assays and criteria certification for the qualifications is presented. (Author)

  3. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  4. Operating and test experience of EBR-II

    International Nuclear Information System (INIS)

    Sackett, J.I.

    1991-01-01

    EBR-II has operated for 27 years, the longest for any Liquid Metal Reactor (LMR) power plant. During that time, much has been learned about successful LMR operation and design. The basic lesson is that conservatism in design can pay significant dividends in operating reliability. Furthermore, such conservatism need not mean high cost. The EBR-II system emphasizes simplicity, minimizing the number of valves in the heat transport system, for example, and simplifying the primary heat-transport-system layout. Another lesson is that emphasizing reliability of the steam generating system at the sodium-water interface (by using duplex tubes in the case of EBR-II) has been well worth the higher initial costs; no problems with leakage have been encountered in EBR-II's operating history. Locating spent fuel storage in the primary tank and providing for decay heat removal by natural connective flow have also been contributors to EBR-II's success. The ability to accommodate loss of forced cooling or loss of heat sink passively has resulted in benefits for simplification, primarily through less reliance on emergency power and in not requiring the secondary sodium or steam systems to be safety grade. Also, the 'piped-pool' arrangement minimizes thermal stress to the primary tank and enhances natural convective flow. These benefits have been realized through a history of operation that has seen EBR-II evolve through four major phases in its test programs, culminating in its present mission as the Integral Fast Reactor (IFR) prototype. (author)

  5. Flow visualization of a monoleaflet and bileaflet mechanical heart valve in a pneumatic ventricular assist device using a PIV system.

    Science.gov (United States)

    Lee, Hwansung; Tatsumi, Eisuke; Taenaka, Yoshiyuki

    2010-01-01

    Our group is developing a new type of pulsatile pneumatic ventricular assist device (PVAD) that uses the Medtronic Hall tilting disc valve (M-H valve). Although tilting disc valves have good washout effect inside the blood pump, they are no longer in common clinical use and may be difficult to obtain in the future. To investigate the stability of the Sorin Bicarbon valve (S-B valve) in our PVAD, we constructed a model pump made of an acrylic resin with the same configuration as our PVAD and attempted to compare the flow visualization upstream and downstream of the outlet position valve between the M-H valve and the S-B valve using a particle image velocimetry (PIV) method. The outlet S-B valve had faster closure than the M-H valve. The maximum flow velocity was greater than with the M-H valve. The maximum Reynolds shear stress (RSS) of the M-H valve reached 150 N/m(2) and that of the S-B valve reached 300 N/m(2) upstream during the end-systolic and early-diastolic phases. In both valves, the maximum RSS upstream of the valve was higher than downstream of the valve because of the regurgitation flow during valve closure. In addition, the maximum viscous shear stress reached above 2 N/m(2), which occupied only about 1%-1.5% of the maximum RSS.

  6. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  7. Analysis of failure and maintenance experiences of motor operated valves in a Finnish nuclear power plant

    International Nuclear Information System (INIS)

    Simola, K.; Laakso, K.

    1992-01-01

    Operating experiences from 1981 up to 1989 of totally 104 motor operated closing valves (MOV) in different safety systems at TVO I and II nuclear power units were analysed in a systematic way. The qualitative methods used were failure mode and effects analysis (FMEA) and maintenance effects and criticality analysis (MECA). The failure descriptions were obtained from power plant's computerized failure reporting system. The reported 181 failure events were reanalysed and sorted according to specific classifications developed for the MOV function. Filled FMEA and MECA sheets on individual valves were stored in a microcomputer data base for further analyses. Analyses were performed for the failed mechanical and electrical valve parts, ways of detection of failure modes, failure effects, and repair and unavailability times

  8. Prospera Digital Phase II: Financial inclusion for low-income women ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Prospera Digital Phase II: Financial inclusion for low-income women in Mexico ... a research network in Latin America, to identify barriers and opportunities to scale up ... Call for new OWSD Fellowships for Early Career Women Scientists now open ... conference of McGill's Institute for the Study of International Development.

  9. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  10. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  11. Phase II cancer clinical trials for biomarker-guided treatments.

    Science.gov (United States)

    Jung, Sin-Ho

    2018-01-01

    The design and analysis of cancer clinical trials with biomarker depend on various factors, such as the phase of trials, the type of biomarker, whether the used biomarker is validated or not, and the study objectives. In this article, we demonstrate the design and analysis of two Phase II cancer clinical trials, one with a predictive biomarker and the other with an imaging prognostic biomarker. Statistical testing methods and their sample size calculation methods are presented for each trial. We assume that the primary endpoint of these trials is a time to event variable, but this concept can be used for any type of endpoint.

  12. Causalities between CO2, electricity, and other energy variables during phase I and phase II of the EU ETS

    International Nuclear Information System (INIS)

    Keppler, Jan Horst; Mansanet-Bataller, Maria

    2010-01-01

    The topic of this article is the analysis of the interplay between daily carbon, electricity and gas price data with the European Union Emission Trading System (EU ETS) for CO 2 emissions. In a first step we have performed Granger causality tests for Phase I of the EU ETS (January 2005 until December 2007) and the first year of Phase II of the EU ETS (2008). The analysis includes both spot and forward markets - given the close interactions between the two sets of markets. The results show that during Phase I coal and gas prices, through the clean dark and spark spread, impacted CO 2 futures prices, which in return Granger caused electricity prices. During the first year of the Phase II, the short-run rent capture theory (in which electricity prices Granger cause CO 2 prices) prevailed. On the basis of the qualitative results of the Granger causality tests we obtained the formulation testable equations for quantitative analysis. Standard OLS regressions yielded statistically robust and theoretically coherent results. (author)

  13. The first preparative solution phase synthesis of melanotan II

    Directory of Open Access Journals (Sweden)

    2008-10-01

    Full Text Available Melanotan II is a synthetic cyclic heptapeptide used to prevent a sunlight-induced skin cancer by stimulating the skin tanning process. In this paper we report the first solution phase synthesis of the title compound. The hexapeptide sequence has been assembled by [(2+2+1+1] scheme. After removing the orthogonal protection, a carbodiimide mediated lactamization, involving the ε-amino group of lysine and γ-carboxy group of aspartic acid, led to a cyclic intermediate. Appending N-acetylnorleucine concluded the assembly of melanotan II molecule. Protection of the lateral groups in arginine and tryptophan was omitted for atom and step economy reasons. The total synthesis of melanotan II was accomplished in 12 steps with 2.6% overall yield, affording >90% pure peptide without using preparative chromatography.

  14. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  15. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  16. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  17. Phase I/Phase II Study of Blinatumomab in Pediatric Patients With Relapsed/Refractory Acute Lymphoblastic Leukemia.

    Science.gov (United States)

    von Stackelberg, Arend; Locatelli, Franco; Zugmaier, Gerhard; Handgretinger, Rupert; Trippett, Tanya M; Rizzari, Carmelo; Bader, Peter; O'Brien, Maureen M; Brethon, Benoît; Bhojwani, Deepa; Schlegel, Paul Gerhardt; Borkhardt, Arndt; Rheingold, Susan R; Cooper, Todd Michael; Zwaan, Christian M; Barnette, Phillip; Messina, Chiara; Michel, Gérard; DuBois, Steven G; Hu, Kuolung; Zhu, Min; Whitlock, James A; Gore, Lia

    2016-12-20

    Purpose Blinatumomab is a bispecific T-cell engager antibody construct targeting CD19 on B-cell lymphoblasts. We evaluated the safety, pharmacokinetics, recommended dosage, and potential for efficacy of blinatumomab in children with relapsed/refractory B-cell precursor acute lymphoblastic leukemia (BCP-ALL). Methods This open-label study enrolled children treatment cycles. Primary end points were maximum-tolerated dosage (phase I) and complete remission rate within the first two cycles (phase II). Results We treated 49 patients in phase I and 44 patients in phase II. Four patients had dose-limiting toxicities in cycle 1 (phase I). Three experienced grade 4 cytokine-release syndrome (one attributed to grade 5 cardiac failure); one had fatal respiratory failure. The maximum-tolerated dosage was 15 µg/m 2 /d. Blinatumomab pharmacokinetics was linear across dosage levels and consistent among age groups. On the basis of the phase I data, the recommended blinatumomab dosage for children with relapsed/refractory ALL was 5 µg/m 2 /d for the first 7 days, followed by 15 µg/m 2 /d thereafter. Among the 70 patients who received the recommended dosage, 27 (39%; 95% CI, 27% to 51%) achieved complete remission within the first two cycles, 14 (52%) of whom achieved complete minimal residual disease response. The most frequent grade ≥ 3 adverse events were anemia (36%), thrombocytopenia (21%), and hypokalemia (17%). Three patients (4%) and one patient (1%) had cytokine-release syndrome of grade 3 and 4, respectively. Two patients (3%) interrupted treatment after grade 2 seizures. Conclusion This trial, which to the best of our knowledge was the first such trial in pediatrics, demonstrated antileukemic activity of single-agent blinatumomab with complete minimal residual disease response in children with relapsed/refractory BCP-ALL. Blinatumomab may represent an important new treatment option in this setting, requiring further investigation in curative indications.

  18. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  19. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  20. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  1. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  2. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  3. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  4. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  5. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  6. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  7. Lightweight Design of an HTS Coil for the VASIMR Experiment, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II SBIR contract Tai-Yang Research Company of Tennessee proposes to design, fabricate, and test an ultra-lightweight High Temperature Superconducting...

  8. Surgical Outcome of Ahmed Valve Implantation in Mexican Patients with Neovascular Glaucoma.

    Science.gov (United States)

    Hernandez-Oteyza, Alejandra; Lazcano-Gomez, Gabriel; Jimenez-Roman, Jesus; Hernandez-Garciadiego, Carlos

    2014-01-01

    To describe clinical results of Ahmed glaucoma valve implantation in Mexican patients with neovascular glaucoma (NVG). We reviewed records of 60 eyes of 60 patients with NVG who underwent Ahmed valve implantation, with a follow-up period of 1 year. We identified successful and failed cases and compared baseline and follow-up characteristics to identify possible differences between both groups. We classified 36 eyes (60%) as successful and 24 (40%) as failed cases. We found a significant difference in success rate in patients who had a hypertensive phase at any time during the follow-up period (OR = 5.15, CI = 1.49-20.15, p = 0.004). Patients in the success group showed a statistically significant decrease in the number of glaucoma medications 1 year after surgery (p Ahmed valve surgical failure in patients with NVG. How to cite this article: Hernandez-Oteyza A, Lazcano-Gomez G, Jimenez-Roman J, Hernandez-Garciadiego C. Surgical Outcome of Ahmed Valve Implantation in Mexican Patients with Neovascular Glaucoma. J Curr Glaucoma Pract 2014;8(3):86-90.

  9. [Study on the phase II metabolites of phenoprolamine hydrochloride in rat bile by LC/DAD/MSD].

    Science.gov (United States)

    Ding, L; Zhang, Z X; Ni, P Z; Wang, G J; An, D K

    2001-06-01

    To study the phase II metabolites of phenoprolamine hydrochloride (DDPH) in rat bile. DDPH was administered by i.p. to bile duct-cannulated rats. Bile samples were collected before drug administration and up to 12 h after drug administration. After being purified and enriched with C-18 SPE columns the rat bile samples were analyzed by LC/DAD/MSD to identify the peaks of phase II metabolites. The fractions of phase II metabolites were prepared by HPLC and treated with beta-glucuronidase, and then were purified and enriched with C-18 SPE columns and analyzed by LC/DAD/MSD. The corresponding reference standards of DDPH phase I metabolites were analyzed by LC/DAD/MSD under identical conditions. The peaks M7, M8 and M9 in the chromatograms of rat bile samples were the phase II metabolites of DDPH and the enzymatic hydrolysates of M7, M8 and M9 were 1-(2, 6-dimethyl-4-hydroxyphenoxy)-2-(3, 4-methoxyphenylethylamino)-propane (M3), 1-(2, 6-dimethyl-3-hydroxyphenoxy)-2-(3, 4-methoxyphenylethylamino)-propane (M2) and 1-(2,6-dimethylphenoxy)-2-(3-methoxy-4-hydroxyphenylethyl-amino)-propane (M1) respectively. beta-1-O-[3,5-dimethyl-4-[-2-methyl-2-(3,4-dimethoxy-phenylethylamino)- ethoxy]-phenyl]-glucuronic acid (M7, glucuronide of M3), beta-1-O-[2, 4-dimethyl-3-[2-methyl-2-(3, 4-dimethoxy-phenylethylamino)-ethoxy]-phenyl]-glucuronic acid (M8, glucuronide of M2) and beta-1-O-[2-methoxy-4-[1-methyl-2-(2, 6-dimethylphenoxy)-ethylamino-ethyl]-phenyl]-glucuronic acid (M9, glucuronide of M1) were the phase II metabolites of DDPH in rat bile.

  10. Life cycle and economic efficiency analysis phase II : durable pavement markings.

    Science.gov (United States)

    2011-04-01

    This report details the Phase II analysis of the life cycle and economic efficiency of inlaid tape : and thermoplastic. Waterborne paint was included as a non-durable for comparison purposes : only. In order to find the most economical product for sp...

  11. Magnetic sensor for nondestructive evaluation of deteriorated prestressing strand : phase II.

    Science.gov (United States)

    2011-08-01

    This report gives an account of the execution and achievements in Phase II of the project completed through August 2011. The main objective of this project is to advance the practical development of a nondestructive testing and evaluation method usin...

  12. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  13. Phase-II Associative Memory ASIC Specifications

    CERN Document Server

    Stabile, Alberto; Warren, Matthew; Green, Barry; Konstantinidis, Nikolaos; Motuk, Halil Erdem; Frontini, Luca; Liberali, Valentino; Crescioli, Francesco; Fedi, Giacomo; Sotiropoulou, Calliope-louisa; De Canio, Francesco; Traversi, Gianluca; Shojaii, Seyed Ruhollah; Kubota, Takashi; Calderini, Giovanni; Palla, Fabrizio; Checcucci, Bruno; Spiller, Laurence Anthony; Mcnamara, Peter Charles

    2018-01-01

    This documents defines the specifications for the Associative Memory ASIC for Phase-II. The work-flow toward the final ASIC is organized in the following three steps • AM08 prototype: small area MPW prototype to test all the full custom features, the VHDL logic and the I/O. This chip must be fully functional with smaller memory area than the final ASIC; • AM09pre pre-production: full area ASIC to be fabricated with a full-mask set pilot run. Production corner wafers will be created; • AM09 production: full area ASIC with refinements for the mass production. The AM09 will be developed built on the AM08 extending the memory area, therefore the specification of both versions must be compatible.

  14. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  15. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    International Nuclear Information System (INIS)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y.

    2014-01-01

    Flow characteristic curves are plotted by calculating the ratio of the measured mass flow rate versus the theoretical mass flow rate. The flow characteristic curves are utilized to accurately test the performance of the control valve of turbine system to ensure the highest controllability and reliability of the power conversion system of large and small power plants. Turbine converts the kinetic energy of steam to mechanical energy of rotor blades in power conversion system. The electrical energy output from the generator of which the rotor is coupled with that of the turbine depends on the rotation velocity of the turbine bucket. The rotation velocity is proportional to the mass flow rate (steam or gas) to the turbine through valves and nozzles. The turbine comprises fast acting governing control valves and stop valves acting against the seat in the flow passage in the closed position. The turbine control valve regulates the mass flow rate entering the first nozzle of a turbine. The main function of stop valve is to close the fluid inlet rapidly in response to a fast close signal to swiftly cut off the flow through the valve inlet. Both these valves contribute attractively to improvement of the power system transient stability as well. To improve the efficiency of power conversion system many investigation have been done by researcher by focusing on the cycle layout or working fluid or by improving the flow path of the working fluid. The main focus is to find out the best option for combined cycle power plant by analyzing four different cycle configuration. Next research phase focused on different way to enhance the cycle efficiency. As the electrical power output from the generator is proportional to the mass flow rate to the turbine through the valve, it should preferably operate linearly. In reality, however, the valve has the various flow characteristics pursuant to the stem lift. Thus, the flow characteristic and control performance are needed to be designed

  16. Numerical Analysis of Combined Valve Hydrodynamic Characteristics for Turbine System

    Energy Technology Data Exchange (ETDEWEB)

    Bhowmik, P. K.; Shamim, J. A.; Gairola, A.; Arif, M.; Suh, Kune Y. [Seoul National Univ., Seoul (Korea, Republic of)

    2014-05-15

    Flow characteristic curves are plotted by calculating the ratio of the measured mass flow rate versus the theoretical mass flow rate. The flow characteristic curves are utilized to accurately test the performance of the control valve of turbine system to ensure the highest controllability and reliability of the power conversion system of large and small power plants. Turbine converts the kinetic energy of steam to mechanical energy of rotor blades in power conversion system. The electrical energy output from the generator of which the rotor is coupled with that of the turbine depends on the rotation velocity of the turbine bucket. The rotation velocity is proportional to the mass flow rate (steam or gas) to the turbine through valves and nozzles. The turbine comprises fast acting governing control valves and stop valves acting against the seat in the flow passage in the closed position. The turbine control valve regulates the mass flow rate entering the first nozzle of a turbine. The main function of stop valve is to close the fluid inlet rapidly in response to a fast close signal to swiftly cut off the flow through the valve inlet. Both these valves contribute attractively to improvement of the power system transient stability as well. To improve the efficiency of power conversion system many investigation have been done by researcher by focusing on the cycle layout or working fluid or by improving the flow path of the working fluid. The main focus is to find out the best option for combined cycle power plant by analyzing four different cycle configuration. Next research phase focused on different way to enhance the cycle efficiency. As the electrical power output from the generator is proportional to the mass flow rate to the turbine through the valve, it should preferably operate linearly. In reality, however, the valve has the various flow characteristics pursuant to the stem lift. Thus, the flow characteristic and control performance are needed to be designed

  17. Purification and H-1 NMR spectroscopic characterization of phase II metabolites of tolfenamic acid

    DEFF Research Database (Denmark)

    Sidelmann, U. G.; Christiansen, E.; Krogh, L.

    1997-01-01

    samples obtained on days 7 to 10 from a human volunteer after oral administration of 200 mg of the drug three times per day (steady-state plasma concentration). The metabolites of tolfenamic acid were initially concentrated by preparative solid phase extraction (PSPE) chromatography, thereby removing...... the endogenous polar compounds that are present in the urine. The individual metabolites were purified by preparative high performance liquid chromatography (HPLC) and then identified using H-1 NMR, Both one- and two-dimensional NMR experiments were performed to identify the phase II metabolites of tolfenamic......), and N-(2-methyl-4-hydroxyphenyl)-anthranilic acid (11) were identified. The phase II metabolites (5-11) had not previously been identified in urine from humans administered tolfenamic acid. The phase I metabolites of the glucuronides 7, 8, 10, and 11 were identified here for the first time. An HPLC...

  18. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  19. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  20. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  1. Towards real-time cardiovascular magnetic resonance-guided transarterial aortic valve implantation: In vitro evaluation and modification of existing devices

    Directory of Open Access Journals (Sweden)

    Ladd Mark E

    2010-10-01

    Full Text Available Abstract Background Cardiovascular magnetic resonance (CMR is considered an attractive alternative for guiding transarterial aortic valve implantation (TAVI featuring unlimited scan plane orientation and unsurpassed soft-tissue contrast with simultaneous device visualization. We sought to evaluate the CMR characteristics of both currently commercially available transcatheter heart valves (Edwards SAPIEN™, Medtronic CoreValve® including their dedicated delivery devices and of a custom-built, CMR-compatible delivery device for the Medtronic CoreValve® prosthesis as an initial step towards real-time CMR-guided TAVI. Methods The devices were systematically examined in phantom models on a 1.5-Tesla scanner using high-resolution T1-weighted 3D FLASH, real-time TrueFISP and flow-sensitive phase-contrast sequences. Images were analyzed for device visualization quality, device-related susceptibility artifacts, and radiofrequency signal shielding. Results CMR revealed major susceptibility artifacts for the two commercial delivery devices caused by considerable metal braiding and precluding in vivo application. The stainless steel-based Edwards SAPIEN™ prosthesis was also regarded not suitable for CMR-guided TAVI due to susceptibility artifacts exceeding the valve's dimensions and hindering an exact placement. In contrast, the nitinol-based Medtronic CoreValve® prosthesis was excellently visualized with delineation even of small details and, thus, regarded suitable for CMR-guided TAVI, particularly since reengineering of its delivery device toward CMR-compatibility resulted in artifact elimination and excellent visualization during catheter movement and valve deployment on real-time TrueFISP imaging. Reliable flow measurements could be performed for both stent-valves after deployment using phase-contrast sequences. Conclusions The present study shows that the Medtronic CoreValve® prosthesis is potentially suited for real-time CMR-guided placement

  2. A Fire Safety Certification System for Board and Care Operators and Staff. SBIR Phase II: Final Report.

    Science.gov (United States)

    Walker, Bonnie L.

    This report describes Phase II of a project which developed a system for delivering fire safety training to board and care providers who serve adults with developmental disabilities. Phase II focused on developing and pilot testing a "train the trainers" workshop for instructors and field testing the provider's workshop. Evaluation of…

  3. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  4. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  5. Expanded Operational Temperature Range for Space Rated Li-Ion Batteries, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Quallion's Phase II proposal calls for expanding the nominal operation range of its space rated lithium ion cells, while maintaining their long life capabilities. To...

  6. OrFPGA: An Empirical Performance Tuning Tool for FPGA Designs, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In this Phase II STTR project, RNET and its subcontractors are proposing to fully develop an empirical performance optimization tool called OrFPGA that efficiently...

  7. Battery Separator Membrane Having a Selectable Thermal Shut-Down Temperature, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — This Small Business Innovation Research Phase II proposal to NASA requests $596,750.96 support for Policell Technologies, Inc. to develop a series of separator...

  8. Efficient Integration, Validation and Troubleshooting in Multimodal Distributed Diagnostic Schemes, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — In general, development and validation of diagnostic models for complex safety critical systems are time and cost intensive jobs. The proposed Phase-II effort will...

  9. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  10. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  11. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  12. Acute normovolemic hemodilution is not beneficial in patients undergoing primary elective valve surgery

    Directory of Open Access Journals (Sweden)

    Virmani Sanjula

    2010-01-01

    Full Text Available The objective of this study was to evaluate the effectiveness of acute normovolemic hemodilution (ANH as a sole method of reducing allogenic blood requirement in patients undergoing primary elective valve surgery. One hundred eighty eight patients undergoing primary elective valve surgery were prospectively randomized into two groups: Group I (n=100 acted as control and in Group II (n=88 autologous blood was removed (10% of estimated blood volume in patients with hemoglobin (Hb > 12g% and 7% when the Hb was < 12g% in the pre-cardiopulmonary bypass (CPB period for subsequent re-transfusion after protamine administration. The autologous blood withdrawn was replaced simultaneously with an equal volume of hydroxyl-ethyl starch solution. Banked blood was transfused in both the groups when Hb was ≤6g % on CPB and ≤8g% after CPB. Platelets were transfused when the count fell to < 100´10 9 /L and fresh frozen plasma (FFP was transfused whenever there was diffuse bleeding with laboratory evidence of coagulopathy. The two groups were comparable as regards demographic data, type of surgical procedures performed, duration of CPB and ischemia, duration of elective ventilation and re-exploration for excessive bleeding. The autologous blood withdrawn in patients with Hb≥12g% was 288.3±69.4 mL and 244.4±41.3 mL with Hb < 12g% (P=NS. The Hb concentration (g % was comparable pre-operatively (Group I= 12.1±1.6, Group II= 12.4±1.4, on postoperative day 1 (Group I =10.3±1.1, Group II= 10.6±1.2 and day 7 (Group I = 10.9±1.5, Group II=10.4±1.5. However, the lowest Hb recorded on CPB was significantly lower in Group II (Group I =7.7±1.2, Group II=6.7±0.9, P < 0.05. There was no difference in the chest tube drainage (Group I =747.2±276.5 mL, Group II=527.6±399.5 mL, blood transfusion (Group I=1.1±1.0 units vs. Group II=1.3±1.0 units intra-operatively and Group I=1.7±1.2 units vs. Group II=1.7±1.4 units post-operatively and FFP transfusion (Group I

  13. Plasma-wall Interaction Studies in the Start-up Phase of TJ-II

    International Nuclear Information System (INIS)

    De la Cal, E.; Tabares, F.L.; Tafalla, D.

    1998-01-01

    The aim of this work is to present some first plasma-wall interaction studies made during the first experimental campaign of TJ-II. The different sections contain independent contributions presented orally in the fusion division of the Euratom-Ciemat association during 1998: I. Density limit during the start-up phase of TJ-II : are we limited by radiation?. II. Temporal evolution of oxygen in the plasma during an experimental day. III. The contribution of helium to the plasma electron density IV. First studies of the S.O.L. diffusion coefficient and its dependence with the boundary plasma parameters. (Author) 3 refs

  14. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  15. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  16. Right miniparasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations: a propensity-adjusted analysis.

    Science.gov (United States)

    Chiu, Kuan M; Chen, Robert J; Lin, Tzu Y; Chen, Jer S; Huang, Jin H; Huang, Chun Y; Chu, Shu H

    2016-02-01

    Limited real-world data existed for mini-parasternotomy approach with good sample size in Asian cohorts and most previous studies were eclipsed by case heterogeneity. The goal of this study was to compare safety and quality outcomes of cardiac non-coronary valve operations by mini-parasternotomy and full sternotomy approaches on risk-adjusted basis. METHODS From our hospital database, we retrieved the cases of non-coronary valve operations from 1 January 2005 to 31 December 2012, including re-do, emergent, and combined procedures. Estimated EuroScore-II and propensity score for choosing mini-parasternotomy were adjusted for in the regression models on hospital mortality, complications (pneumonia, stroke, sepsis, etc.), and quality parameters (length of stay, ICU time, ventilator time, etc.). Non-complicated cases, defined as survival to discharge, ventilator use not over one week, and intensive care unit stay not over two weeks, were used for quality parameters. There were 283 mini-parasternotomy and 177 full sternotomy cases. EuroScore-II differed significantly (medians 2.1 vs. 4.7, P<0.001). Propensity scores for choosing mini-parasternotomy were higher with lower EuroScore-II (OR=0.91 per 1%, P<0.001), aortic regurgitation (OR=2.3, P=0.005), and aortic non-mitral valve disease (OR=3.9, P<0.001). Adjusted for propensity score and EuroScore-II, mini-parasternotomy group had less pneumonia (OR=0.32, P=0.043), less sepsis (OR=0.31, P=0.045), and shorter non-complicated length of stay (coefficient=-7.2 (day), P<0.001) than full sternotomy group, whereas Kaplan-Meier survival, non-complicated ICU time, non-complicated ventilator time, and 30-day mortality did not differ significantly. The propensity-adjusted analysis demonstrated encouraging safety and quality outcomes for mini-parasternotomy valve operation in carefully selected patients.

  17. Brain Oxygen Optimization in Severe Traumatic Brain Injury Phase-II: A Phase II Randomized Trial.

    Science.gov (United States)

    Okonkwo, David O; Shutter, Lori A; Moore, Carol; Temkin, Nancy R; Puccio, Ava M; Madden, Christopher J; Andaluz, Norberto; Chesnut, Randall M; Bullock, M Ross; Grant, Gerald A; McGregor, John; Weaver, Michael; Jallo, Jack; LeRoux, Peter D; Moberg, Dick; Barber, Jason; Lazaridis, Christos; Diaz-Arrastia, Ramon R

    2017-11-01

    A relationship between reduced brain tissue oxygenation and poor outcome following severe traumatic brain injury has been reported in observational studies. We designed a Phase II trial to assess whether a neurocritical care management protocol could improve brain tissue oxygenation levels in patients with severe traumatic brain injury and the feasibility of a Phase III efficacy study. Randomized prospective clinical trial. Ten ICUs in the United States. One hundred nineteen severe traumatic brain injury patients. Patients were randomized to treatment protocol based on intracranial pressure plus brain tissue oxygenation monitoring versus intracranial pressure monitoring alone. Brain tissue oxygenation data were recorded in the intracranial pressure -only group in blinded fashion. Tiered interventions in each arm were specified and impact on intracranial pressure and brain tissue oxygenation measured. Monitors were removed if values were normal for 48 hours consecutively, or after 5 days. Outcome was measured at 6 months using the Glasgow Outcome Scale-Extended. A management protocol based on brain tissue oxygenation and intracranial pressure monitoring reduced the proportion of time with brain tissue hypoxia after severe traumatic brain injury (0.45 in intracranial pressure-only group and 0.16 in intracranial pressure plus brain tissue oxygenation group; p injury after severe traumatic brain injury based on brain tissue oxygenation and intracranial pressure values was consistent with reduced mortality and increased proportions of patients with good recovery compared with intracranial pressure-only management; however, the study was not powered for clinical efficacy. Management of severe traumatic brain injury informed by multimodal intracranial pressure and brain tissue oxygenation monitoring reduced brain tissue hypoxia with a trend toward lower mortality and more favorable outcomes than intracranial pressure-only treatment. A Phase III randomized trial to assess

  18. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  19. Strut fracture with Björk-Shiley 70 degrees convexo-concave valve. An international multi-institutional follow-up study.

    Science.gov (United States)

    Ericsson, A; Lindblom, D; Semb, G; Huysmans, H A; Thulin, L I; Scully, H E; Bennett, J G; Ostermeyer, J; Grunkemeier, G L

    1992-01-01

    Between 1980 and 1983, 831 Björk-Shiley 70 degrees convexo-concave prosthetic heart valves were implanted at five institutions in Sweden, Germany. The Netherlands, and Canada. As of January 1991, there were 34 outlet strut fractures occurring from 0.2 to 10.1 years (median = 4.6 years) after implantation. In addition, there were 28 sudden, unexplained deaths. The mortality after strut fracture was 84%. The mortality after emergency valve replacement for strut fracture was 50%. The 10-year actuarial fracture rate (standard error) was 10.5 (2.4)% for large (29-33 mm) valves vs. 3.3 (1.2)% for 21-27 mm valves (P less than 0.001). Within valve size groups, fracture rates for aortic and mitral valves were similar. Cox regression analysis found only valve size to be significantly associated with strut fracture. There is a further subgrouping of the valves according to the manufacturer: group I are the earlier large 29-33 mm) valves; group II are the later large valves; group III are the small size (21-27 mm) valves. The risk of strut fracture was highest in group I (12.3% at 10 years) with an approximatively constant hazard (1.4% per year). A comparison was made with a statistical model incorporating all cases reported to the manufacturer. This model estimates fracture rates approximately 63%-73% of those found in the present study. These findings lead us to recommend that group I patients should be considered for elective reoperation on an individual basis, giving careful attention to risk factors and contraindications.

  20. Ten-year results of the Freedom Solo stentless heart valve: excellent haemodynamics but progressive valve dysfunction in the long term.

    Science.gov (United States)

    Sponga, Sandro; Barbera, Mila Della; Pavoni, Daisy; Lechiancole, Andrea; Mazzaro, Enzo; Valente, Marialuisa; Nucifora, Gaetano; Thiene, Gaetano; Livi, Ugolino

    2017-05-01

    Freedom Solo (FS) is a pericardial stentless heart valve showing excellent haemodynamic performance at mid-term. The aim of this study was to evaluate the long-term performance of such bioprostheses. Between December 2004 and November 2009, 109 patients (31 men; mean age 76 ± 6 years) underwent aortic valve replacement with FS. Preoperatively, the mean NYHA class was 2.5 ± 0.7, the mean EuroSCORE II, 2.8 ± 2.5. Mean prosthesis size was 22.7 ± 1.9 mm; concomitant procedures were performed in 65 patients. Structural valve deterioration (SVD) was diagnosed according to the Valve Academic Research Consortium-2 definition. Two patients (1.8%) died within 30 days. Follow-up (72 ± 36 months) was 100% completed. The 1-, 5- and 10-year actuarial survival rates were 89, 73 and 42%, respectively, with 8 valve-related deaths; the actuarial freedom from SVD was 99, 93 and 76%. During 61 ± 39 months of follow-up, echocardiographic findings worsened progressively: At discharge, 3-5 and 7-9 years, the mean gradient was 8 ± 4, 12 ± 11 and 19 ± 19 mmHg ( P  < 0.01); the indexed effective orifice area was 1.0 ± 0.2, 0.9 ± 0.2 and 0.8 ± 0.3 cm 2 /m 2 ( P  < 0.01). Of the 13 patients who developed SVD, it was due to aortic stenosis in 11. SVD was a predictor of cardiovascular mortality at univariate analysis (HR 2.87, 1.12-7.29); 2 explanted prostheses showed massive calcium deposits with mean calcium and phosphorus contents of 234 ± 16 and 116 ± 7 mg/g dry weight, respectively. The FS bioprosthesis shows excellent mid-term clinical and haemodynamic results and offers an alternative to other valves, particularly in the case of a small aortic annulus. Worsening of FS performance was observed at late follow-up because of progressive SVD with stenosis, questioning whether it should be used in patients with a long life expectancy. © The Author 2017. Published by Oxford University Press on behalf of the

  1. Solid State Transmitters for Water Vapor and Ozone DIAL Systems, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The focus of this Select Phase II program is to build and deliver laser components both for airborne water vapor and ozone DIAL systems. Specifically, Fibertek...

  2. Scaled Model Technology for Flight Research of General Aviation Aircraft, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Our proposed future Phase II activities are aimed at developing a scientifically based "tool box" for flight research using scaled models. These tools will be of...

  3. Coordinated Control of Multi-Agent Systems in Rapidly Varying Environments, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — The main objective of this Phase II STTR project is to develop advanced control algorithms that enable multiple autonomous agents to perform complex tasks in rapidly...

  4. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  5. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  6. Solids throttling valves for coal conversion and utilization development. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Sine, G.C.

    1980-11-01

    A complete test system to test, evaluate, and develop control valves for slurry letdown service in coal liquefaction plants is needed. The site identified for the test system was the SRC II Pilot Plant located at Ft. Lewis, Washington. The US Department of Energy, Morgantown Energy Technology Center, requested a test system design that would enable testing of various configuration letdown valves that would be compatible with the existing facility and have minimum impact on Pilot Plant operations. Drawings and specifications for such a test system were prepared, coordinated with Ft. Lewis personnel, revised to reflect Ft. Lewis operating personnel comments, and approved for use by the Morgantown Energy Technology Center. These drawings and specifications will enable the test system to be built, installed, and integrated with the existing facility by a general contractor.

  7. Magneto-capillary valve for integrated purification and enrichment of nucleic acids and proteins.

    Science.gov (United States)

    den Dulk, Remco C; Schmidt, Kristiane A; Sabatté, Gwénola; Liébana, Susana; Prins, Menno W J

    2013-01-07

    We describe the magneto-capillary valve (MCV) technology, a flexible approach for integrated biological sample preparation within the concept of stationary microfluidics. Rather than moving liquids in a microfluidic device, discrete units of liquid are present at fixed positions in the device and magnetic particles are actuated between the fluids. The MCV concept is characterized by the use of two planar surfaces at a capillary mutual distance, with specific features to confine the fluids by capillary forces, and the use of a gas or a phase-change material separating the stationary aqueous liquids. We have studied the physics of magneto-capillary valving by quantifying the magnetic force as a function of time and position, which reveals the balance of magnetic, capillary and frictional forces in the system. By purification experiments with a fluorescent tracer we have measured the amount of co-transported liquid, which is a key parameter for efficient purification. To demonstrate the versatility of the technology, several MCV device architectures were tested in a series of biological assays, showing the purification and enrichment of nucleic acids and proteins. Target recovery comparable to non-miniaturized commercial kits was observed for the extraction of DNA from human cells in buffer, using a device architecture with patterned air valves. Experiments using an enrichment module and patterned air valves demonstrate a 40-fold effective enrichment of DNA in buffer. DNA was also successfully purified from blood plasma using paraffin phase-change valves. Finally, the enrichment of a protein biomarker (prostate-specific antigen) using geometrical air valves resulted in a 7-fold increase of detection signal. The MCV technology is versatile, offers extensive freedom for the design of fully integrated systems, and is expected to be manufacturable in a cost-effective way. We conclude that the MCV technology can become an important enabling technology for point

  8. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  9. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  10. [Fungal community structure in phase II composting of Volvariella volvacea].

    Science.gov (United States)

    Chen, Changqing; Li, Tong; Jiang, Yun; Li, Yu

    2014-12-04

    To understand the fungal community succession during the phase II of Volvariella volvacea compost and clarify the predominant fungi in different fermentation stages, to monitor the dynamic compost at the molecular level accurately and quickly, and reveal the mechanism. The 18S rDNA-denaturing gradient gel electrophoresis (DGGE) and sequencing methods were used to analyze the fungal community structure during the course of compost. The DGGE profile shows that there were differences in the diversity of fungal community with the fermentation progress. The diversity was higher in the stages of high temperature. And the dynamic changes of predominant community and relative intensity was observed. Among the 20 predominant clone strains, 9 were unknown eukaryote and fungi, the others were Eurotiales, Aspergillus sp., Melanocarpus albomyces, Colletotrichum sp., Rhizomucor sp., Verticillium sp., Penicillium commune, Microascus trigonosporus and Trichosporon lactis. The 14 clone strains were detected in the stages of high and durative temperature. The fungal community structure and predominant community have taken dynamic succession during the phase II of Volvariella volvacea compost.

  11. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  12. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  13. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  14. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  15. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  16. Development and Validation of Methodology to Model Flow in Ventilation Systems Commonly Found in Nuclear Facilities - Phase II

    Energy Technology Data Exchange (ETDEWEB)

    Strons, Philip [Argonne National Lab. (ANL), Argonne, IL (United States); Bailey, James L. [Argonne National Lab. (ANL), Argonne, IL (United States); Davis, John [Argonne National Lab. (ANL), Argonne, IL (United States); Grudzinski, James [Argonne National Lab. (ANL), Argonne, IL (United States); Hlotke, John [Argonne National Lab. (ANL), Argonne, IL (United States)

    2016-03-01

    In this report we present the results of the Phase II analysis and testing of the flow patterns encountered in the Alpha Gamma Hot Cell Facility (AGHCF), as well as the results from an opportunity to expand upon field test work from Phase I by the use of a Class IIIb laser. The addition to the Phase I work is covered before proceeding to the results of the Phase II work, followed by a summary of findings.

  17. Free-Piston Stirling Power Conversion Unit for Fission Power System, Phase II Final Report

    Science.gov (United States)

    Wood, J. Gary; Stanley, John

    2016-01-01

    In Phase II, the manufacture and testing of two 6-kW(sub e)Stirling engines was completed. The engines were delivered in an opposed 12-kW(sub e) arrangement with a common expansion space heater head. As described in the Phase I report, the engines were designed to be sealed both hermetically and with a bolted O-ring seal. The completed Phase II convertor is in the bolted configuration to allow future disassembly. By the end of Phase II, the convertor had passed all of the final testing requirements in preparation for delivery to the NASA Glenn Research Center. The electronic controller also was fabricated and tested during Phase II. The controller sets both piston amplitudes and maintains the phasing between them. It also sets the operating frequency of the machine. Details of the controller are described in the Phase I final report. Fabrication of the direct-current to direct-current (DC-DC) output stage, which would have stepped down the main controller output voltage from 700 to 120 V(sub DC), was omitted from this phase of the project for budgetary reasons. However, the main controller was successfully built, tested with the engines, and delivered. We experienced very few development issues with this high-power controller. The project extended significantly longer than originally planned because of yearly funding delays. The team also experienced several hardware difficulties along the development path. Most of these were related to the different thermal expansions of adjacent parts constructed of different materials. This issue was made worse by the large size of the machine. Thermal expansion problems also caused difficulties in the brazing of the opposed stainless steel sodium-potassium (NaK) heater head. Despite repeated attempts Sunpower was not able to successfully braze the opposed head under this project. Near the end of the project, Glenn fabricated an opposed Inconel NaK head, which was installed prior to delivery for testing at Glenn. Engine

  18. Large Format LW Type-II SLS FPAs for Space Applications, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — This Phase I SBIR proposes to develop high performance (low dark current, high quantum efficiency, and low NEdT) infrared epitaxy materials based on Type II Strained...

  19. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  20. Enginnering development of coal-fired high performance power systems phase II and III

    International Nuclear Information System (INIS)

    1998-01-01

    This report presents work carried out under contract DE-AC22-95PC95144 ''Engineering Development of Coal-Fired High Performance Systems Phase II and III.'' The goals of the program are to develop a coal-fired high performance power generation system (HIPPS) that is capable of: thermal efficiency (HHV) >47%; NOx, SOx, and particulates 65% of heat input; all solid wastes benign; cost of electricity <90% of present plants. Phase I, which began in 1992, focused on the analysis of various configurations of indirectly fired cycles and on technical assessments of alternative plant subsystems and components, including performance requirements, developmental status, design options, complexity and reliability, and capital and operating costs. Phase I also included preliminary R ampersand D and the preparation of designs for HIPPS commercial plants approximately 300 MWe in size. This phase, Phase II, involves the development and testing of plant subsystems, refinement and updating of the HIPPS commercial plant design, and the site selection and engineering design of a HIPPS prototype plant. Work reported herein is from: Task 2.2 HITAF Air Heaters; Task 6 HIPPS Commercial Plant Design Update

  1. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  2. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  3. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  4. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  5. North American trial results at 1 year with the Sorin Freedom SOLO pericardial aortic valve.

    Science.gov (United States)

    Heimansohn, David; Roselli, Eric E; Thourani, Vinod H; Wang, Shaohua; Voisine, Pierre; Ye, Jian; Dabir, Reza; Moon, Michael

    2016-02-01

    A North American prospective, 15-centre Food and Drug Administration (FDA) valve trial was designed to assess the safety and effectiveness of the Freedom SOLO stentless pericardial aortic valve in the treatment of surgical aortic valve disease. Beginning in 2010, 251 patients (mean: 74.7 ± 7.5 years), were recruited in the Freedom SOLO aortic valve trial. One hundred eighty-nine patients have been followed for at least 1 year and are the basis for this review. Preoperatively, 54% of patients had NYHA functional class III or IV symptoms, and the majority of patients had a normal ejection fraction (EF) (median EF = 61%). Concomitant procedures were performed in 61.9% of patients, with coronary artery bypass grafting (CABG) (48.7%) being the most common followed by a MAZE procedure (13.7%). Reoperations were performed in 8.5% of patients in the study. The entire cohort of 251 patients enrolled had 7 deaths prior to 30 days, 2 of which were valve-related (aspiration pneumonia and sudden death) and 5 were not valve-related. There were 11 deaths after 30 days, 1 valve-related (unknown cardiac death) and 10 not valve-related. Five valves were explanted, 3 early (endocarditis, acute insufficiency and possible root dissection) and 2 late (endocarditis). Thirty-day adverse events include arrhythmias requiring permanent pacemaker (4.2%), thromboembolic events (3.7%) and thrombocytopenia (7.4%). One-year follow-up of all 189 patients demonstrated mean gradients for valve sizes 19, 21, 23, 25 and 27 mm of 11.7, 7.8, 6.3, 4.6 and 5.0 mmHg, respectively. Effective orifice areas for the same valve sizes were 1.2, 1.3, 1.6, 1.8 and 1.9 cm(2), respectively. Ninety-six percent of patients (181/189) were in NYHA class I or II at the 1-year follow-up. The Freedom SOLO stentless pericardial aortic valve demonstrated excellent haemodynamics and a good safety profile out to the 1 year of follow-up. © The Author 2015. Published by Oxford University Press on behalf of the European

  6. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  7. Valve-stem-packing improvement study. Final report

    International Nuclear Information System (INIS)

    Adey, C.W.; Klein, J.J.

    1982-08-01

    By employing questionnaires and face-to-face interviews with valve and valve packing manufacturers, as well as nuclear plant personnel, an understanding of valve stem packing leakage problems from each of the three viewpoints was developed. This information, in-house experience, and available technical literature were used to develop specific recommendations for valve manufacturers, valve packing manufacturers, and nuclear plant valve users. It was generally recommended that each these groups make better use of graphite packing. The questionnaires and interviews indicated that increased usage of graphite packing over the last few years has reduced the incidence of valve packing problems. To confirm this, a survey of Licensee Event Reports (LERs) from 1972 to 1980 was undertaken using the keywords Valve and Packing. A statistical analysis of the LER data confirms that the adoption of graphite packing has significantly reduced valve stem leakage

  8. Final Phase II report : QuickSite(R) investigation, Everest, Kansas.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M. (Environmental Research)

    2003-11-01

    this reason, the CCC/USDA is conducting an environmental site investigation to determine the source(s) and extent of the carbon tetrachloride contamination at Everest and to assess whether the contamination requires remedial action. The investigation at Everest is being performed by the Environmental Research Division of Argonne National Laboratory. Argonne is a nonprofit, multidisciplinary research center operated by the University of Chicago for the U.S. Department of Energy (DOE). The CCC/USDA has entered into an interagency agreement with DOE, under which Argonne provides technical assistance to the CCC/USDA with environmental site characterization and remediation at its former grain storage facilities. At these facilities, Argonne is applying its QuickSite{reg_sign} environmental site characterization methodology. This methodology has been applied successfully at a number of former CCC/USDA facilities in Kansas and Nebraska and has been adopted by the American Society for Testing and Materials (ASTM 1998) as standard practice for environmental site characterization. Phase I of the QuickSite{reg_sign} investigation examined the key geologic, hydrogeologic, and hydrogeochemical relationships that define potential contaminant migration pathways at Everest (Argonne 2001). Phase II of the QuickSite{reg_sign} investigation at Everest was undertaken with the primary goal of delineating and improving understanding of the distribution of carbon tetrachloride contamination in groundwater at this site and the potential source area(s) that might have contributed to this contamination. To address this goal, four specific technical objectives were developed to guide the Phase II field studies. Sampling of near-surface soils at the former Everest CCC/USDA facility that was originally planned for Phase I had to be postponed until October 2000 because of access restrictions. Viable vegetation was not available for sampling then. This period is termed the first session of Phase II

  9. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  10. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  11. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  12. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  13. Advancements in valve technology and industry lessons lead to improved plant reliability and cost savings

    International Nuclear Information System (INIS)

    Sharma, V.; Kalsi, M.S.

    2005-01-01

    Plant reliability and safety hinges on the proper functioning of several valves. Recent advancements in valve technology have resulted in new analytical and test methods for evaluating and improving valve and actuator reliability. This is especially significant in critical service applications in which the economic impact of a valve failure on production, outage schedules and consequential damages far surpasses the initial equipment purchase price. This paper presents an overview of recent advances in valve technology driven by reliability concerns and cost savings objectives without comprising safety in the Nuclear Power Industry. This overview is based on over 27 years of experience in supporting US and International nuclear power utilities, and contributing to EPRI, and NSSS Owners' Groups in developing generic models/methodologies to address industry wide issues; performing design basis reviews; and implementing plant-wide valve reliability improvement programs. Various analytical prediction software and hardware solutions and training seminars are now available to implement valve programs covering power plants' lifecycle from the construction phase through life extension and power up rate. These tools and methodologies can enhance valve-engineering activities including the selection, sizing, proper application, condition monitoring, failure analysis, and condition based maintenance optimization with a focus on potential bad actors. This paper offers two such examples, the Kalsi Valve and Actuator Program (KVAP) and Check Valve Analysis and Prioritization (CVAP) [1-3, 8, 9, 11-13]. The advanced, validated torque prediction models incorporated into KVAP software for AOVs and MOVs have improved reliability of margin predictions and enabled cost savings through elimination of unwarranted equipment modifications. CVAP models provides a basis to prioritize the population of valves recommended for preventive maintenance, inspection and/or modification, allowing

  14. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  15. Functional design criteria for project W-252, phase II liquid effluent treatment and disposal. Revision 2

    International Nuclear Information System (INIS)

    Hatch, C.E.

    1995-05-01

    This document is the Functional Design Criteria for Project W-252. Project W-252 provides the scope to provide BAT/AKART (best available technology...) to 200 Liquid Effluent Phase II streams (B-Plant). This revision (Rev. 2) incorporates a major descoping of the project. The descoping was done to reflect a combination of budget cutting measures allowed by a less stringent regulatory posture toward the Phase II streams

  16. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  17. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  18. Chemically modified activated carbon with 1-acylthiosemicarbazide for selective solid-phase extraction and preconcentration of trace Cu(II), Hg(II) and Pb(II) from water samples.

    Science.gov (United States)

    Gao, Ru; Hu, Zheng; Chang, Xijun; He, Qun; Zhang, Lijun; Tu, Zhifeng; Shi, Jianping

    2009-12-15

    A new sorbent 1-acylthiosemicarbazide-modified activated carbon (AC-ATSC) was prepared as a solid-phase extractant and applied for removing of trace Cu(II), Hg(II) and Pb(II) prior to their determination by inductively coupled plasma optical emission spectrometry (ICP-OES). The separation/preconcentration conditions of analytes were investigated, including effects of pH, the shaking time, the sample flow rate and volume, the elution condition and the interfering ions. At pH 3, the maximum static adsorption capacity of Cu(II), Hg(II) and Pb(II) onto the AC-ATSC were 78.20, 67.80 and 48.56 mg g(-1), respectively. The adsorbed metal ions were quantitatively eluted by 3.0 mL of 2% CS(NH2)2 and 2.0 mol L(-1) HCl solution. Common coexisting ions did not interfere with the separation. According to the definition of IUPAC, the detection limits (3sigma) of this method for Cu(II), Hg(II) and Pb(II) were 0.20, 0.12 and 0.45 ng mL(-1), respectively. The relative standard deviation under optimum conditions is less than 4.0% (n=8). The prepared sorbent was applied for the preconcentration of trace Cu(II), Hg(II) and Pb(II) in certified and water samples with satisfactory results.

  19. Infective endocarditis following transcatheter edge-to-edge mitral valve repair: A systematic review.

    Science.gov (United States)

    Asmarats, Lluis; Rodriguez-Gabella, Tania; Chamandi, Chekrallah; Bernier, Mathieu; Beaudoin, Jonathan; O'Connor, Kim; Dumont, Eric; Dagenais, François; Paradis, Jean-Michel; Rodés-Cabau, Josep

    2018-05-10

    To assess the clinical characteristics, management, and outcomes of patients diagnosed with infective endocarditis (IE) after edge-to-edge mitral valve repair with the MitraClip device. Transcatheter edge-to-edge mitral valve repair has emerged as an alternative to surgery in high-risk patients. However, few data exist on IE following transcatheter mitral procedures. Four electronic databases (PubMed, Google Scholar, Embase, and Cochrane Library) were searched for original published studies on IE after edge-to-edge transcatheter mitral valve repair from 2003 to 2017. A total of 10 publications describing 12 patients with definitive IE (median age 76 years, 55% men) were found. The mean logistic EuroSCORE/EuroSCORE II were 41% and 45%, respectively. The IE episode occurred early (within 12 months post-procedure) in nine patients (75%; within the first month in five patients). Staphylococcus aureus was the most frequent (60%) causal microorganism, and severe mitral regurgitation was present in all cases but one. Surgical mitral valve replacement (SMVR) was performed in most (67%) patients, and the mortality associated with the IE episode was high (42%). IE following transcatheter edge-to-edge mitral valve repair is a rare but life-threatening complication, usually necessitating SMVR despite the high-risk profile of the patients. These results highlight the importance of adequate preventive measures and a prompt diagnosis and treatment of this serious complication. © 2018 Wiley Periodicals, Inc.

  20. Right mini-parasternotomy may be a good minimally invasive alternative to full sternotomy for cardiac valve operations-a propensity-adjusted analysis.

    Science.gov (United States)

    Chiu, K M; Chen, R J; Lin, T Y; Chen, J S; Huang, J H; Huang, C Y; Chu, S H

    2014-03-26

    Limited realworld data existed for miniparasternotomy approach with good sample size in Asian cohorts and most previous studies were eclipsed by case heterogeneity. The goal of this study was to compare safety and quality outcomes of cardiac noncoronary valve operations by miniparasternotomy and full sternotomy approaches on riskadjusted basis. From our hospital database, we retrieved the cases of non-coronary valve operations from 1 January 2005 to 31 December 2012, including re-do, emergent, and combined procedures. Estimated EuroScore-II and propensity score for choosing mini-parasternotomy were adjusted for in the regression models on hospital mortality, complications (pneumonia, stroke, sepsis, etc.), and quality parameters (length of stay, ICU time, ventilator time, etc.). Non-complicated cases, defined as survival to discharge, ventilator use not over one week, and intensive care unit stay not over two weeks, were used for quality parameters. There were 283 miniparasternotomy and 177 full sternotomy cases. EuroScore-II differed significantly (medians 2.1 vs. 4.7, p<0.001). Propensity scores for choosing miniparasternotomy were higher with lower EuroScore-II (OR=0.91 per 1%, p<0.001), aortic regurgitation (OR=2.3, p=0.005), and aortic non-mitral valve disease (OR=3.9, p<0.001). Adjusted for propensity score and EuroScore-II, mini-parasternotomy group had less pneumonia (OR=0.32, p=0.043), less sepsis (OR=0.31, p=0.045), and shorter non-complicated length of stay (coefficient=7.2 (day), p<0.001) than full sternotomy group, whereas Kaplan-Meier survival, non-complicated ICU time, non-complicated ventilator time, and 30-day mortality did not differ significantly. The propensity-adjusted analysis demonstrated encouraging safety and quality outcomes for mini-parasternotomy valve operation in carefully selected patients.

  1. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  2. The association between gastroesophageal flap valve function and gastroesophageal reflux symptoms.

    Science.gov (United States)

    Keskin, O; Kalkan, Ç; Yaman, A; Tüzün, A; Soykan, I

    2017-01-01

    Upper gastrointestinal endoscopic examination is usually the first step in the evaluation of patients with suspected gastroesopageal reflux disease. The primary aim of this study was to investigate the association between gastroesophageal flap valve function (GEFV) and gastroesophapgeal reflux symptoms in patients undergoing routine upper endoscopy. Patients and methods: 1507 patients were included into the study and the GEFV graded I to IV as follows: Hill I-II: normal GEFV, and Hill III-IV: abnormal GEFV. Patients in abnormal GEFV group had a higher incidence of reflux symptoms compared to normal GEFV group (53.4% vs 47.4% for heartburn p=0.03 and 53.2% vs 42.4% for regurgitation, preflux symptoms were in abnormal GEFV group. In patients undergoing endoscopy because of reflux symptoms, Grade III-IV valve was detected more commonly in patients with reflux symptoms compared to patients without reflux symptoms (p = 0.01). Patients with abnormal valves (Hill grades III and IV) but without reflux symptoms, esophagitis and hiatal hernia should be evaluated individually by means of the presence of gastroesophageal reflux disease which means that GEFV is not a good indicator of reflux disease. © Acta Gastro-Enterologica Belgica.

  3. Holifield Heavy Ion Research Facility. Phase II

    International Nuclear Information System (INIS)

    Ball, J.B.; Hudson, E.D.; Lord, R.S.; Johnson, J.W.; Martin, J.A.; McNeilly, G.S.; Milner, W.T.; Mosko, S.W.; Sayer, R.O.; Robinson, R.L.

    1979-01-01

    The Holifield Heavy Ion Research Facility, with the completion of Phase I in late 1979, will include the Oak Ridge Isochronous Cyclotron (ORIC) and associated research areas, the new 25 MV tandem accelerator with new research areas for tandem beams, and modifications to utilize the ORIC as a booster accelerator. The combination of the tandem and ORIC will provide beam energies of 25 MeV/A for light heavy ions and 6 MeV/A up to A = 160. This paper discusses plans for a Phase II expansion of the facility to include an isochronous cyclotron with superconducting magnet and reconfiguration of the existing research areas and the ORIC vault to handle the higher energy beams from the new cyclotron. The new booster cyclotron is a low-flutter high-spiral design patterned after the MSU K = 800 design, with a central magnetic field of about 5 tesla and an extraction radius of 1 meter. The new beam transport system will incorporate an rf beam-splitter system that will be able to deliver successive beam pulses to two or three experiment areas

  4. Long-term results of aortic valve-sparing operations in patients with Marfan syndrome.

    Science.gov (United States)

    David, Tirone E; Armstrong, Sue; Maganti, Manjula; Colman, Jack; Bradley, Timothy J

    2009-10-01

    The appropriateness of aortic valve-sparing operations in patients with Marfan syndrome has been questioned. This study examines the long-term results of these operations in patients with Marfan syndrome. From 1988 to 2006, 103 consecutive patients with Marfan syndrome (mean age, 37 +/- 12 years) and aortic root aneurysm had aortic valve-sparing operations. Emergency surgery was performed in 11 patients: 8 for acute type A aortic dissection and 3 for unexplained persistent chest pain. Fourteen patients also had mitral valve surgery. The technique of aortic valve reimplantation was used in 77 patients, and aortic root remodeling was used in 26 patients. Patients were followed prospectively and underwent annual echocardiographic studies. The mean follow-up was 7.3 +/- 4.2 years and 100% complete. There was 1 operative death and 5 late deaths. Four of the 6 deaths were due to complications of aortic dissections. The patients' survival at 15 years was 87.2% compared with 95.6% for the general population of Ontario matched for age and sex. Seven patients had important aortic insufficiency: 4 mild to moderate, 2 moderate, and 1 moderate to severe. Freedom from greater than mild aortic insufficiency at 15 years was 79.2%. Three patients, all after aortic root remodeling, had aortic valve replacement, 2 for aortic insufficiency and 1 for endocarditis. At the most recent follow-up, 97 patients were alive: 86 were in functional class I, and 11 were in functional class II. Aortic valve-sparing operations provided excellent clinical outcomes in this series of patients with Marfan syndrome. Postoperatively, complications of aortic dissections were the leading cause of death.

  5. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  6. NASA's GeneLab Phase II: Federated Search and Data Discovery

    Science.gov (United States)

    Berrios, Daniel C.; Costes, Sylvain V.; Tran, Peter B.

    2017-01-01

    GeneLab is currently being developed by NASA to accelerate 'open science' biomedical research in support of the human exploration of space and the improvement of life on earth. Phase I of the four-phase GeneLab Data Systems (GLDS) project emphasized capabilities for submission, curation, search, and retrieval of genomics, transcriptomics and proteomics ('omics') data from biomedical research of space environments. The focus of development of the GLDS for Phase II has been federated data search for and retrieval of these kinds of data across other open-access systems, so that users are able to conduct biological meta-investigations using data from a variety of sources. Such meta-investigations are key to corroborating findings from many kinds of assays and translating them into systems biology knowledge and, eventually, therapeutics.

  7. NASAs GeneLab Phase II: Federated Search and Data Discovery

    Science.gov (United States)

    Berrios, Daniel C.; Costes, Sylvain; Tran, Peter

    2017-01-01

    GeneLab is currently being developed by NASA to accelerate open science biomedical research in support of the human exploration of space and the improvement of life on earth. Phase I of the four-phase GeneLab Data Systems (GLDS) project emphasized capabilities for submission, curation, search, and retrieval of genomics, transcriptomics and proteomics (omics) data from biomedical research of space environments. The focus of development of the GLDS for Phase II has been federated data search for and retrieval of these kinds of data across other open-access systems, so that users are able to conduct biological meta-investigations using data from a variety of sources. Such meta-investigations are key to corroborating findings from many kinds of assays and translating them into systems biology knowledge and, eventually, therapeutics.

  8. Design review report: AN valve pit upgrades for Project W-314, tank farm restoration and safe operations

    International Nuclear Information System (INIS)

    Boes, K.A.

    1998-01-01

    This Design Review Report (DRR) documents the contractor design verification methodology and records associated with project W-314's AN Valve Pit Upgrades design package. The DRR includes the documented comments and their respective dispositions for this design. Acceptance of the comment dispositions and closure of the review comments is indicated by the signatures of the participating reviewers. Project W-314, Tank Farm Restoration and Safe Operations, is a project within the Tank Waste Remediation System (TWRS) Tank Waste Retrieval Program. This project provides capital upgrades for the existing Hanford tank farms' waste transfer, instrumentation, ventilation, and electrical infrastructure systems. To support established TWRS programmatic objectives, the project is organized into two distinct phases. The initial focus of the project (i.e., Phase 1) is on waste transfer system upgrades needed to support the TWRS Privatization waste feed delivery system. Phase 2 of the project will provide upgrades to support resolution of regulatory compliance issues, improve tank infrastructure reliability, and reduce overall plant operating/maintenance costs. Within Phase 1 of the W-314 project, the waste transfer system upgrades are further broken down into six major packages which align with the project's work breakdown structure. Each of these six sub-elements includes the design, procurement, and construction activities necessary to accomplish the specific tank farm upgrades contained within the package. The first package to be performed is the AN Valve Pit Upgrades package. The scope of the modifications includes new pit cover blocks, valve manifolds, leak detectors, transfer line connections (for future planned transfer lines), and special protective coating for the 241-AN-A and 241-AN-B valve pits

  9. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  10. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  11. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  12. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  13. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  14. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  15. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  16. 76 FR 55947 - Industrial Relations Promotion Project, Phase II in Vietnam

    Science.gov (United States)

    2011-09-09

    ... DEPARTMENT OF LABOR Office of the Secretary Industrial Relations Promotion Project, Phase II in... to perform the type of activity to be funded.. DAI, through its Industrial Relations Promotion... provided a letter in support of continued funding of DAI/IRRP based, on part, on the importance of the...

  17. The STAR beam energy scan phase II physics and upgrades

    Czech Academy of Sciences Publication Activity Database

    Yang, C.; Adamczyk, L.; Adkins, J. K.; Agakishiev, G.; Bielčík, J.; Bielčíková, Jana; Chaloupka, P.; Federič, Pavol; Rusňák, Jan; Rusňáková, O.; Šimko, Miroslav; Šumbera, Michal; Vértési, Robert

    2017-01-01

    Roč. 967, č. 11 (2017), s. 800-803 ISSN 0375-9474 R&D Projects: GA MŠk LG15001; GA MŠk LM2015054 Institutional support: RVO:61389005 Keywords : STAR collaboration * BES-II * detector upgrade * QCD phase diagram * physics oppotrunity Subject RIV: BG - Nuclear, Atomic and Molecular Physics, Colliders OBOR OECD: Nuclear physics Impact factor: 1.916, year: 2016

  18. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  19. Evaluation of SPACE code for simulation of inadvertent opening of spray valve in Shin Kori unit 1

    International Nuclear Information System (INIS)

    Kim, Seyun; Youn, Bumsoo

    2013-01-01

    SPACE code is expected to be applied to the safety analysis for LOCA (Loss of Coolant Accident) and Non-LOCA scenarios. SPACE code solves two-fluid, three-field governing equations and programmed with C++ computer language using object-oriented concepts. To evaluate the analysis capability for the transient phenomena in the actual nuclear power plant, an inadvertent opening of spray valve in startup test phase of Shin Kori unit 1 was simulated with SPACE code. To evaluate the analysis capability for the transient phenomena in the actual nuclear power plant, an inadvertent opening of spray valve in startup test phase of Shin Kori unit 1 was simulated with SPACE code

  20. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve