WorldWideScience

Sample records for valves detection channels

  1. Valve exploiting the principle of a side channel turbine

    Directory of Open Access Journals (Sweden)

    Jandourek Pavel

    2017-01-01

    Full Text Available The article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Reducing valves are a source of hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the valve and the turbine. The basis for the design is the loss characteristics of the valve. Thereby creating a kind of turbine valve with speed-controlled flow in dependence of runner revolution.

  2. Acoustic valve leak detection in nuclear plants

    International Nuclear Information System (INIS)

    Dimmick, J.G.; Dickey, J.W.

    1983-01-01

    Internal valve leakage is a hidden energy loss and can cause or prolong a forced outage. Recent advances in acoustic detection of internal valve leakage have reduced piping system maintenance costs, unnecessary downtime, and energy waste. Extremely short payback periods have been reported by plants applying this technology to preventive maintenance, troubleshooting, energy conservation and outage planning. Sensors temporarily attached to the outside of valves and connected to the instruments detect ultrasonic acoustic emissions which are characteristic of internal valve leakage. Since the sensors are attached to the outside of the valves, the time and expense of dismantling the valves or removing them from the systems are eliminated. This paper describes the instrumentation and specific applications to nuclear plant valves, including independent verification of initial findings. Guidelines for potential users, including instrumentation selection, training requirements, application planning, and the choice of in-house versus contract services are discussed

  3. Autonomous valve for detection of biopolymer degradation

    DEFF Research Database (Denmark)

    Keller, Stephan Urs; Noeth, Nadine-Nicole; Fetz, Stefanie

    2009-01-01

    We present a polymer microvalve that allows the detection of biopolymer degradation without the need of external energy. The valve is based on a polymer container filled with a colored marker solution and closed by a thin lid. This structure is covered by a film of poly(L-lactide) and degradation...... of the biopolymer triggers the release of the color which is detected visually. The autonomous valve has potential for the fast testing of biopolymer degradation under various environmental conditions or by specific enzymes....

  4. 3D capillary valves for versatile capillary patterning of channel walls

    NARCIS (Netherlands)

    Papadimitriou, Vasileios; van den Berg, Albert; Eijkel, Jan C.T.

    2016-01-01

    We demonstrate passive capillary patterning of channel walls with a liquid in situ. Patterning is performed using a novel 3D capillary valve system combining three standard capillary stop valves. A range of different patterns is demonstrated in three channel walls. Capillary patterning was designed

  5. Diesel Engine Valve Clearance Detection Using Acoustic Emission

    Directory of Open Access Journals (Sweden)

    Fathi Elamin

    2010-01-01

    Full Text Available This paper investigated, using experimental method, the suitability of acoustic emission (AE technique for the condition monitoring of diesel engine valve faults. The clearance fault was adjusted experimentally in an exhaust valve and successfully detected and diagnosed in a Ford FSD 425 four-cylinder, four-stroke, in-line OHV, direct injection diesel engine. The effect of faulty exhaust valve clearance on engine performance was monitored and the difference between the healthy and faulty engine was observed from the recorded AE signals. The measured results from this technique show that using only time domain and frequency domain analysis of acoustic emission signals can give a superior measure of engine condition. This concludes that acoustic emission is a powerful and reliable method of detection and diagnosis of the faults in diesel engines and this is considered to be a unique approach to condition monitoring of valve performance.

  6. On the feasibility of detecting flaws in artificial heart valves

    NARCIS (Netherlands)

    Lepelaars, E.S.A.M.; Ooijen, van W.D.R.; Tijhuis, A.G.

    2000-01-01

    Investigates the feasibility of detecting defects in certain artificial heart valves by determining the electromagnetic behavior of some simple models with the aid of thin-wire integral equations. The idea is to use the stationary current that occurs at late times after the excitation of a closed

  7. Channel selection for automatic seizure detection

    DEFF Research Database (Denmark)

    Duun-Henriksen, Jonas; Kjaer, Troels Wesenberg; Madsen, Rasmus Elsborg

    2012-01-01

    Objective: To investigate the performance of epileptic seizure detection using only a few of the recorded EEG channels and the ability of software to select these channels compared with a neurophysiologist. Methods: Fifty-nine seizures and 1419 h of interictal EEG are used for training and testing...... of an automatic channel selection method. The characteristics of the seizures are extracted by the use of a wavelet analysis and classified by a support vector machine. The best channel selection method is based upon maximum variance during the seizure. Results: Using only three channels, a seizure detection...... sensitivity of 96% and a false detection rate of 0.14/h were obtained. This corresponds to the performance obtained when channels are selected through visual inspection by a clinical neurophysiologist, and constitutes a 4% improvement in sensitivity compared to seizure detection using channels recorded...

  8. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Horomichi

    1990-01-01

    The purpose of this study is to estimate the availability of acoustic method for detecting the internal leakage of valves at power plants. Experiments have been carried out on the characteristics of acoustic noise caused by the leak simulated flow. From the experimental results, the mechanism of the acoustic noisegenerated from flow, the relation between acoustic intensity and leak flow velocity, and the characteristics of the acoustic frequency spectrum were clarified. The acoustic method was applied to valves at site, and the background noises were measured in abnormal plant conditions. When the background level is higher than the acoustic signal, the difference between the background noise frequency spectrum and the acoustic signal spectrum provide a very useful leak detection method. (author)

  9. Detection method of internal leakage from valve using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Kitajima, Akira; Suzuki, Akio.

    1990-01-01

    The objective of this study is to estimate the feasibility of the acoustic method for the internal leakage from the valves in power plants. From the experimental results, it was suggested that the acoustic method for the monitoring of leakage was feasible. When the background levels are higher than the acoustic signals from leakage, we can detect the leakage analyzing the spectrum of the remainders which take the background noise from the acoustic signals. (author)

  10. Magnon detection using a ferroic collinear multilayer spin valve.

    Science.gov (United States)

    Cramer, Joel; Fuhrmann, Felix; Ritzmann, Ulrike; Gall, Vanessa; Niizeki, Tomohiko; Ramos, Rafael; Qiu, Zhiyong; Hou, Dazhi; Kikkawa, Takashi; Sinova, Jairo; Nowak, Ulrich; Saitoh, Eiji; Kläui, Mathias

    2018-03-14

    Information transport and processing by pure magnonic spin currents in insulators is a promising alternative to conventional charge-current-driven spintronic devices. The absence of Joule heating and reduced spin wave damping in insulating ferromagnets have been suggested for implementing efficient logic devices. After the successful demonstration of a majority gate based on the superposition of spin waves, further components are required to perform complex logic operations. Here, we report on magnetization orientation-dependent spin current detection signals in collinear magnetic multilayers inspired by the functionality of a conventional spin valve. In Y 3 Fe 5 O 12 |CoO|Co, we find that the detection amplitude of spin currents emitted by ferromagnetic resonance spin pumping depends on the relative alignment of the Y 3 Fe 5 O 12 and Co magnetization. This yields a spin valve-like behavior with an amplitude change of 120% in our systems. We demonstrate the reliability of the effect and identify its origin by both temperature-dependent and power-dependent measurements.

  11. Fuzzy Pattern Classification Based Detection of Faulty Electronic Fuel Control (EFC Valves Used in Diesel Engines

    Directory of Open Access Journals (Sweden)

    Umut Tugsal

    2014-05-01

    Full Text Available In this paper, we develop mathematical models of a rotary Electronic Fuel Control (EFC valve used in a Diesel engine based on dynamic performance test data and system identification methodology in order to detect the faulty EFC valves. The model takes into account the dynamics of the electrical and mechanical portions of the EFC valves. A recursive least squares (RLS type system identification methodology has been utilized to determine the transfer functions of the different types of EFC valves that were investigated in this study. Both in frequency domain and time domain methods have been utilized for this purpose. Based on the characteristic patterns exhibited by the EFC valves, a fuzzy logic based pattern classification method was utilized to evaluate the residuals and identify faulty EFC valves from good ones. The developed methodology has been shown to provide robust diagnostics for a wide range of EFC valves.

  12. Fibrin glue on an aortic cusp detected by transesophageal echocardiography after valve-sparing aortic valve replacement: a case report.

    Science.gov (United States)

    Nakahira, Junko; Ishii, Hisanari; Sawai, Toshiyuki; Minami, Toshiaki

    2015-03-07

    Fibrin glue is used commonly during cardiac surgery but can behave as an intracardiac abnormal foreign body following surgery. There have been few such cases reported, and they were typically noticed only because of the resulting catastrophic cardiac conditions, such as valvular malfunction. We report a case where, for the first time, transesophageal echocardiography was used to detected fibrin glue that was adherent to the ventricular side of a patient's aortic valve immediately after aortic declamping. A 45-year-old Japanese man with Marfan syndrome underwent an aortic valve-sparing operation to treat moderate aortic valve regurgitation resulting from enlargement of his right coronary cusp. Fibrin glue was lightly applied to the suture line between the previous and new grafts. Transesophageal echocardiography performed prior to weaning from the cardiopulmonary bypass revealed mild aortic valve regurgitation in addition to a mobile membranous structure attached to the ventricular side of his aortic valve. It was identified as fibrin glue. We resolved the regurgitation by removing the fibrin glue and repeating the aortic cusp plication. The patient had no complications during recovery. Fibrin glue can act as an intracardiac foreign body and lead to a potentially fatal embolism. We demonstrated the use of transesophageal echocardiography to detect a fibrin glue-derived intracardiac abnormal foreign body and to confirm its removal. To the best of our knowledge, this is the first case where fibrin glue adherent to the aortic valve was detected by transesophageal echocardiography. These findings demonstrate the importance of using transesophageal echocardiography during cardiac surgery that involves using biological glues.

  13. Detection circuit of solenoid valve operation and control rod drive mechanism utilizing the circuit

    International Nuclear Information System (INIS)

    Ono, Takehiko.

    1976-01-01

    Object: To detect the operation of a plunger and detect opening and closing operations of a solenoid valve driving device due to change in impedance of a coil for driving the solenoid valve to judge normality and abnormality of the solenoid valve, thereby increasing reliance and safety of drive and control apparatus of control rods. Structure: An arrangement comprises a drive and operation detector section wherein the operation of a solenoid driving device for controlling power supply to a coil for driving the solenoid valve to control opening and closing of the solenoid valve, and a plunger operation detector section for detecting change in impedance of the drive coil to detect that the plunger of the solenoid valve is either in the opening direction or closing direction, whereby a predetermined low voltage such as not to activate the solenoid valve even when the solenoid valve is open or closed is applied to detect a current flowing into the coil at that time, thus detecting an operating state of the plunger. (Yoshino, Y.)

  14. System for detecting operating errors in a variable valve timing engine using pressure sensors

    Science.gov (United States)

    Wiles, Matthew A.; Marriot, Craig D

    2013-07-02

    A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

  15. Implementing wavelet packet transform for valve failure detection using vibration and acoustic emission signals

    International Nuclear Information System (INIS)

    Sim, H Y; Ramli, R; Abdullah, M A K

    2012-01-01

    The efficiency of reciprocating compressors relies heavily on the health condition of its moving components, most importantly its valves. Previous studies showed good correlation between the dynamic response and the physical condition of the valves. These can be achieved by employing vibration technique which is capable of monitoring the response of the valve, and acoustic emission technique which is capable of detecting the valves' material deformation. However, the relationship/comparison between the two techniques is rarely investigated. In this paper, the two techniques were examined using time-frequency analysis. Wavelet packet transform (WPT) was chosen as the multi-resolution analysis technique over continuous wavelet transform (CWT), and discrete wavelet transform (DWT). This is because WPT could overcome the high computational time and high redundancy problem in CWT and could provide detailed analysis of the high frequency components compared to DWT. The features of both signals can be extracted by evaluating the normalised WPT coefficients for different time window under different valve conditions. By comparing the normalised coefficients over a certain time frame and frequency range, the feature vectors revealing the condition of valves can be constructed. One way analysis of variance was employed on these feature vectors to test the significance of data under different valve conditions. It is believed that AE signals can give a better representation of the valve condition as it can detect both the fluid motion and material deformation of valves as compared to the vibration signals.

  16. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  17. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  18. Analysis of Poiseuille Flow Property in Two-Dimensional Mi-cro Channels of Microfluidic Pneumatic Micro-Valve

    Science.gov (United States)

    Yang, Shaohua; Long, Wei; Chen, Yajun

    2018-03-01

    In this paper, the control mechanism and mathematical description of the microfluidic flow in the microfluidic process of the PDMS membrane type pneumatic micro-valve were studied. The velocity and pressure variation law of the velocity field inside micro valve was analyzed by numerical simulation method. The influence of the two kinds of inlet drive modes on the working effect and the pressure flow characteristics of the pneumatic micro-valve was studied. The structure of the elastic solid valve diaphragm under the dual action of the airway and the liquid channel was analyzed. Deformation and stress distribution. The results show that the gas flow in the gas flow channel under the diaphragm by the vacuum part of the role of the formation of a suction gas vortex, pressure-driven mode was easier under the diaphragm to produce a strong gas vortex, resulting in internal and external pressure to promote diaphragm cut-off liquid channel; In the pressure pneumatic mode, the stress at both ends of the diaphragm was smaller, the membrane was not easy to tear failure.

  19. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method

    Science.gov (United States)

    Jiang, Zhinong; Wang, Zijia; Zhang, Jinjie

    2017-01-01

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable. PMID:29244722

  20. Fault Diagnosis of Internal Combustion Engine Valve Clearance Using the Impact Commencement Detection Method.

    Science.gov (United States)

    Jiang, Zhinong; Mao, Zhiwei; Wang, Zijia; Zhang, Jinjie

    2017-12-15

    Internal combustion engines (ICEs) are widely used in many important fields. The valve train clearance of an ICE usually exceeds the normal value due to wear or faulty adjustment. This work aims at diagnosing the valve clearance fault based on the vibration signals measured on the engine cylinder heads. The non-stationarity of the ICE operating condition makes it difficult to obtain the nominal baseline, which is always an awkward problem for fault diagnosis. This paper overcomes the problem by inspecting the timing of valve closing impacts, of which the referenced baseline can be obtained by referencing design parameters rather than extraction during healthy conditions. To accurately detect the timing of valve closing impact from vibration signals, we carry out a new method to detect and extract the commencement of the impacts. The results of experiments conducted on a twelve-cylinder ICE test rig show that the approach is capable of extracting the commencement of valve closing impact accurately and using only one feature can give a superior monitoring of valve clearance. With the help of this technique, the valve clearance fault becomes detectable even without the comparison to the baseline, and the changing trend of the clearance could be trackable.

  1. Automated valve fault detection based on acoustic emission parameters and support vector machine

    Directory of Open Access Journals (Sweden)

    Salah M. Ali

    2018-03-01

    Full Text Available Reciprocating compressors are one of the most used types of compressors with wide applications in industry. The most common failure in reciprocating compressors is always related to the valves. Therefore, a reliable condition monitoring method is required to avoid the unplanned shutdown in this category of machines. Acoustic emission (AE technique is one of the effective recent methods in the field of valve condition monitoring. However, a major challenge is related to the analysis of AE signal which perhaps only depends on the experience and knowledge of technicians. This paper proposes automated fault detection method using support vector machine (SVM and AE parameters in an attempt to reduce human intervention in the process. Experiments were conducted on a single stage reciprocating air compressor by combining healthy and faulty valve conditions to acquire the AE signals. Valve functioning was identified through AE waveform analysis. SVM faults detection model was subsequently devised and validated based on training and testing samples respectively. The results demonstrated automatic valve fault detection model with accuracy exceeding 98%. It is believed that valve faults can be detected efficiently without human intervention by employing the proposed model for a single stage reciprocating compressor. Keywords: Condition monitoring, Faults detection, Signal analysis, Acoustic emission, Support vector machine

  2. Performance Analysis of Iterative Channel Estimation and Multiuser Detection in Multipath DS-CDMA Channels

    Science.gov (United States)

    Li, Husheng; Betz, Sharon M.; Poor, H. Vincent

    2007-05-01

    This paper examines the performance of decision feedback based iterative channel estimation and multiuser detection in channel coded aperiodic DS-CDMA systems operating over multipath fading channels. First, explicit expressions describing the performance of channel estimation and parallel interference cancellation based multiuser detection are developed. These results are then combined to characterize the evolution of the performance of a system that iterates among channel estimation, multiuser detection and channel decoding. Sufficient conditions for convergence of this system to a unique fixed point are developed.

  3. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  4. The availability of the detection method of internal valve leakage using acoustic method

    International Nuclear Information System (INIS)

    Kumagai, Hiromichi; Suzuki, Akio

    1989-01-01

    The purpose of this study is to estimate the availability of acoustic method to the internal leakage of the valves at power plants. The acoustic method was applied to the valves at the site, and the background noise was measured for the abnormal plantcondition. From the comparison of the background noise date with the experimental results as to relation between leakage flow and acoust signal, the minimum leakage flow rates that can be detected by the acoust signal was suggested. When the background levels are higher than the acoust signal, the method described below was considered that the analysis the remainder among the background noise frequency spectrum and the acoustic signal spectrum become a very useful leak detection method. A few experimental examples of the spectrum analysis that varied the background noise characteristic were given. (author)

  5. Detection blockages and valve statues in natural gas pipelines

    Energy Technology Data Exchange (ETDEWEB)

    Dawson, Karl; Short, Gordon; Wang, Xuesong [Pipeline Engineering Ltd, North Yorkshire, (United Kingdom); Lennox, Barry; Lewis, Keith; Turner, John [University of Manchester, Manchester, (United Kingdom); Lewis, Chris [BP exploration, Aberdeen, (United Kingdom)

    2010-07-01

    Detecting features in pipelines containing flowing gas is difficult. This paper investigated a patented acoustic reflectometry technique for detecting defects in gas pipelines. The basic concept of this technique is to inject a pulse of sound into a pipeline and then measure the reflections produced while the signal travels along the length of the pipe. A modification in the internal section of the pipe will produce a reflection which, given with the speed of sound in the gas within the pipeline, provides the location of the feature. Laboratory tests on a 16m rigid PVC pipe and two field trials were undertaken to test this new method. The results showed that acoustic reflectometry can be used to identify features resulting from blockages and leakages. The field tests demonstrated that the method is capable of surveying both small and large diameter pipelines with lengths up to 10 km.

  6. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  7. 40 CFR 61.243-2 - Alternative standards for valves in VHAP service-skip period leak detection and repair.

    Science.gov (United States)

    2010-07-01

    ... VHAP service-skip period leak detection and repair. 61.243-2 Section 61.243-2 Protection of Environment... AIR POLLUTANTS National Emission Standard for Equipment Leaks (Fugitive Emission Sources) § 61.243-2 Alternative standards for valves in VHAP service—skip period leak detection and repair. (a)(1) An owner or...

  8. Efficient Sequence Detection of Multicarrier Transmissions over Doubly Dispersive Channels

    Directory of Open Access Journals (Sweden)

    Hwang Sung-Jun

    2006-01-01

    Full Text Available We propose a high-spectral-efficiency multicarrier system for communication over the doubly dispersive (DD channel which yields very low frame error rate (FER, with quadratic (in the frame length receiver complexity. To accomplish this, we combine a non-(biorthogonal multicarrier modulation (MCM scheme recently proposed by the authors with novel sequence detection (SD and channel estimation (CE algorithms. In particular, our MCM scheme allows us to accurately represent the DD channels otherwise complicated intercarrier interference (ICI and intersymbol interference (ISI response with a relatively small number of coefficients. The SD and CE algorithms then leverage this sparse ICI/ISI structure for low-complexity operation. Our SD algorithm combines a novel adaptive breadth-first search procedure with a new fast MMSE-GDFE preprocessor, while our CE algorithm uses a rank-reduced pilot-aided Wiener technique to estimate only the significant ICI/ISI coefficients.

  9. Estimation of probability density functions of damage parameter for valve leakage detection in reciprocating pump used in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Kyeom; Kim, Tae Yun; Kim, Hyun Su; Chai, Jang Bom; Lee, Jin Woo [Div. of Mechanical Engineering, Ajou University, Suwon (Korea, Republic of)

    2016-10-15

    This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

  10. Estimation of probability density functions of damage parameter for valve leakage detection in reciprocating pump used in nuclear power plants

    International Nuclear Information System (INIS)

    Lee, Jong Kyeom; Kim, Tae Yun; Kim, Hyun Su; Chai, Jang Bom; Lee, Jin Woo

    2016-01-01

    This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage

  11. Estimation of Probability Density Functions of Damage Parameter for Valve Leakage Detection in Reciprocating Pump Used in Nuclear Power Plants

    Directory of Open Access Journals (Sweden)

    Jong Kyeom Lee

    2016-10-01

    Full Text Available This paper presents an advanced estimation method for obtaining the probability density functions of a damage parameter for valve leakage detection in a reciprocating pump. The estimation method is based on a comparison of model data which are simulated by using a mathematical model, and experimental data which are measured on the inside and outside of the reciprocating pump in operation. The mathematical model, which is simplified and extended on the basis of previous models, describes not only the normal state of the pump, but also its abnormal state caused by valve leakage. The pressure in the cylinder is expressed as a function of the crankshaft angle, and an additional volume flow rate due to the valve leakage is quantified by a damage parameter in the mathematical model. The change in the cylinder pressure profiles due to the suction valve leakage is noticeable in the compression and expansion modes of the pump. The damage parameter value over 300 cycles is calculated in two ways, considering advance or delay in the opening and closing angles of the discharge valves. The probability density functions of the damage parameter are compared for diagnosis and prognosis on the basis of the probabilistic features of valve leakage.

  12. Salmonella detection in a microfluidic channel using orbiting magnetic beads

    Science.gov (United States)

    Ballard, Matt; Mills, Zachary; Owen, Drew; Hanasoge, Srinivas; Hesketh, Peter; Alexeev, Alexander

    2015-03-01

    We use three-dimensional simulations to model the detection of salmonella in a complex fluid sample in a microfluidic channel. Salmonella is captured using magnetic microbeads orbiting around soft ferromagnetic discs at the microchannel bottom subjected to a rotating external magnetic field. Numerical simulations are used to model the dynamics of salmonella and microbeads throughout the detection process. We examine the effect of the channel geometry on the salmonella capture, and the forces applied to the salmonella as it is dragged through the fluid after capture. Our findings guide the design of a lab-on-a-chip device to be used for detection of salmonella in food samples in a way that ensures that salmonella captured by orbiting microbeads are preserved until they can be extracted from the system for testing, and are not washed away by the fluid flow or damaged due to the experience of excessive stresses. Such a device is needed to detect bacteria at the food source and prevention of consumption of contaminated food, and also can be used for the detection of a variety of biomaterials of interest from complex fluid samples. Support from USDA and NSF is gratefully acknowledged.

  13. Spin injection and detection in lateral spin valves with hybrid interfaces

    Science.gov (United States)

    Wang, Le; Liu, Wenyu; Ying, Hao; Chen, Luchen; Lu, Zhanjie; Han, Shuo; Chen, Shanshan; Zhao, Bing; Xu, Xiaoguang; Jiang, Yong

    2018-06-01

    Spin injection and detection in lateral spin valves with hybrid interfaces comprising a Co/Ag transparent contact and a Co/MgO/Ag junction (III) are investigated at room temperature in comparison with pure Co/Ag transparent contacts (I) and Co/MgO/Ag junctions (II). The measured spin-accumulation signals of a type III device are five times higher than those for type I. The extracted spin diffusion length in Ag is 180 nm for all three types of devices. The enhancement of the spin signal of the hybrid structure is mainly attributed to the increase of the interfacial spin polarization from the Co/MgO/Ag junction.

  14. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis.

    Science.gov (United States)

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    2016-02-01

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including low-dose CT (FDG-PET) and three-dimensional transoesophageal echocardiography (3D-TEE) may have additional value. This paper reviews the role of these novel imaging tools in the field of PHV obstruction and endocarditis.For acquired PHV obstruction, MDCT is of additional value in mechanical PHVs to differentiate pannus from thrombus as well as to dynamically study leaflet motion and opening/closing angles. For biological PHV obstruction, additional imaging is not beneficial as it does not change patient management. When performed on top of 2D-TTE/TEE, MDCT has additional value for the detection of both vegetations and pseudoaneurysms/abscesses in PHV endocarditis. FDG-PET has no complementary value for the detection of vegetations; however, it appears more sensitive in the early detection of pseudoaneurysms/abscesses. Furthermore, FDG-PET enables the detection of metastatic and primary extra-cardiac infections. Evidence for the additional value of 3D-TEE is scarce.As clinical implications are major, clinicians should have a low threshold to perform additional MDCT in acquired mechanical PHV obstruction. For suspected PHV endocarditis, both FDG-PET and MDCT have complementary value.

  15. Optimal Power Constrained Distributed Detection over a Noisy Multiaccess Channel

    Directory of Open Access Journals (Sweden)

    Zhiwen Hu

    2015-01-01

    Full Text Available The problem of optimal power constrained distributed detection over a noisy multiaccess channel (MAC is addressed. Under local power constraints, we define the transformation function for sensor to realize the mapping from local decision to transmitted waveform. The deflection coefficient maximization (DCM is used to optimize the performance of power constrained fusion system. Using optimality conditions, we derive the closed-form solution to the considered problem. Monte Carlo simulations are carried out to evaluate the performance of the proposed new method. Simulation results show that the proposed method could significantly improve the detection performance of the fusion system with low signal-to-noise ratio (SNR. We also show that the proposed new method has a robust detection performance for broad SNR region.

  16. Detection of amastigote-like forms in the valve of Phlebotomus papatasi infected with Leishmania major

    Directory of Open Access Journals (Sweden)

    Nestor Añez

    2003-06-01

    Full Text Available A massive and homogeneous amount of amastigote-like forms was detected in the stomodeal valve (SV and the thoracic mid-gut (TMG of Leishmania major-infected Phlebotomus papatasi, which received a second blood meal 13 to 21 days post-infection on healthy anaesthetized hamsters. After re-feeding, the infected sand flies were dissected out to examine the morphology of the parasite in SV, TMG and the abdominal mid-gut (AMG. Different promastigote forms were seen in the infected flies. Among these included typical promastigotes (nectomonads and haptomonads, paramastigotes, metacyclic promastigotes and, in some samples, the here-reported amastigote-like forms. The Leishmania amastigote-like forms were detected in the SV of sand flies with 14, 18 and 21 days of infection as well as in the TMG at 13 and 18 days post-infection. However, the amastigote-like forms were not detected in the AMG. Factors such as the acidic pH predominating the TMG and the SV, as well as the temperature of the ingested blood, among others, are suggested as contributing to the transformation of the typical promastigotes into the amastigote-like forms. The significance of this finding is discussed and the possible biological advantage for transmission of Leishmania is considered.

  17. The association of incidentally detected heart valve calcification with future cardiovascular events

    OpenAIRE

    Gondrie, Martijn J. A.; van der Graaf, Yolanda; Jacobs, Peter C.; Oen, Ay L.; Mali, Willem P. Th. M.

    2010-01-01

    Objectives This study aims to investigate the prognostic value of incidental aortic valve calcification (AVC), mitral valve calcification (MVC) and mitral annular calcification (MAC) for cardiovascular events and non-rheumatic valve disease in particular on routine diagnostic chest CT. Methods The study followed a case-cohort design. 10410 patients undergoing chest CT were followed for a median period of 17 months. Patients referred for cardiovascular disease were excluded. A random sample of...

  18. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    Energy Technology Data Exchange (ETDEWEB)

    O' Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R. (Department of Diagnostic Radiology, Victoria General Hospital Halifax, Nova Scotia (Canada))

    1991-09-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess.

  19. Gallium-SPECT in the detection of prosthetic valve endocarditis and aortic ring abscess

    International Nuclear Information System (INIS)

    O'Brien, K.; Barnes, D.; Martin, R.H.; Rae, J.R.

    1991-01-01

    A 52-yr-old man who had a bioprosthetic aortic valve developed Staphylococcus aureus bacteremia. Despite antibiotic therapy he had persistent pyrexia and developed new conduction system disturbances. Echocardiography did not demonstrate vegetations on the valve or an abscess, but gallium scintigraphy using SPECT clearly identified a focus of intense activity in the region of the aortic valve. The presence of valvular vegetations and a septal abscess was confirmed at autopsy. Gallium scintigraphy, using SPECT, provided a useful noninvasive method for the demonstration of endocarditis and the associated valve ring abscess

  20. Polarized object detection in crabs: a two-channel system.

    Science.gov (United States)

    Basnak, Melanie Ailín; Pérez-Schuster, Verónica; Hermitte, Gabriela; Berón de Astrada, Martín

    2018-05-25

    Many animal species take advantage of polarization vision for vital tasks such as orientation, communication and contrast enhancement. Previous studies have suggested that decapod crustaceans use a two-channel polarization system for contrast enhancement. Here, we characterize the polarization contrast sensitivity in a grapsid crab . We estimated the polarization contrast sensitivity of the animals by quantifying both their escape response and changes in heart rate when presented with polarized motion stimuli. The motion stimulus consisted of an expanding disk with an 82 deg polarization difference between the object and the background. More than 90% of animals responded by freezing or trying to avoid the polarized stimulus. In addition, we co-rotated the electric vector (e-vector) orientation of the light from the object and background by increments of 30 deg and found that the animals' escape response varied periodically with a 90 deg period. Maximum escape responses were obtained for object and background e-vectors near the vertical and horizontal orientations. Changes in cardiac response showed parallel results but also a minimum response when e-vectors of object and background were shifted by 45 deg with respect to the maxima. These results are consistent with an orthogonal receptor arrangement for the detection of polarized light, in which two channels are aligned with the vertical and horizontal orientations. It has been hypothesized that animals with object-based polarization vision rely on a two-channel detection system analogous to that of color processing in dichromats. Our results, obtained by systematically varying the e-vectors of object and background, provide strong empirical support for this theoretical model of polarized object detection. © 2018. Published by The Company of Biologists Ltd.

  1. A Multiple-Channel Sub-Band Transient Detection System

    Energy Technology Data Exchange (ETDEWEB)

    David A. Smith

    1998-11-01

    We have developed a unique multiple-channel sub-band transient detection system to record transient electromagnetic signals in carrier-dominated radio environments; the system has been used to make unique observations of weak, transient HF signals. The detection system has made these observations possible through improved sensitivity compared to conventional broadband transient detection systems; the sensitivity improvement is estimated to be at least 20 dB. The increase in sensitivity has been achieved through subdivision of the band of interest (an 18 MHz tunable bandwidth) into eight sub-band independent detection channels, each with a 400 kHz bandwidth and its own criteria. The system generates a system trigger signal when a predetermined number of channels (typically five) trigger within a predetermined window of time (typically 100 ~s). Events are recorded with a broadband data acquisition system sampling at 50 or 100 Msample/s, so despite the fact that the detection system operates on portions of the signal confined to narrow bands, data acquisition is broadband. Between May and September of 1994, the system was used to detect and record over six thousand transient events in the frequency band from 3 to 30 MHz. Approximately 500 of the events have been characterized as paired bursts of radio noise with individual durations of 2 to 10 ps and separations between the bursts of 5 to 160 ps. The paired transients are typically 5 to 40 dB brighter than the background electromagnetic spectrum between carrier signals. We have termed these events SubIonospheric Pulse Pairs (SIPPS) and presently have no explanation as to their source. Our observations of SIPPS resemble observations of TransIonospheric Pulse Pairs (TIPPs) recorded by the Blackboard instrument on the ALEXIS satellite; the source of TIPP events is also unknown. Most of the recorded SIPP events do not exhibit frequency dispersion, implying propagation along a line-of-sight (groundwave) path; but seven of

  2. Nonlinear Algorithms for Channel Equalization and Map Symbol Detection.

    Science.gov (United States)

    Giridhar, K.

    The transfer of information through a communication medium invariably results in various kinds of distortion to the transmitted signal. In this dissertation, a feed -forward neural network-based equalizer, and a family of maximum a posteriori (MAP) symbol detectors are proposed for signal recovery in the presence of intersymbol interference (ISI) and additive white Gaussian noise. The proposed neural network-based equalizer employs a novel bit-mapping strategy to handle multilevel data signals in an equivalent bipolar representation. It uses a training procedure to learn the channel characteristics, and at the end of training, the multilevel symbols are recovered from the corresponding inverse bit-mapping. When the channel characteristics are unknown and no training sequences are available, blind estimation of the channel (or its inverse) and simultaneous data recovery is required. Convergence properties of several existing Bussgang-type blind equalization algorithms are studied through computer simulations, and a unique gain independent approach is used to obtain a fair comparison of their rates of convergence. Although simple to implement, the slow convergence of these Bussgang-type blind equalizers make them unsuitable for many high data-rate applications. Rapidly converging blind algorithms based on the principle of MAP symbol-by -symbol detection are proposed, which adaptively estimate the channel impulse response (CIR) and simultaneously decode the received data sequence. Assuming a linear and Gaussian measurement model, the near-optimal blind MAP symbol detector (MAPSD) consists of a parallel bank of conditional Kalman channel estimators, where the conditioning is done on each possible data subsequence that can convolve with the CIR. This algorithm is also extended to the recovery of convolutionally encoded waveforms in the presence of ISI. Since the complexity of the MAPSD algorithm increases exponentially with the length of the assumed CIR, a suboptimal

  3. Separating rings detection in fuel channels of Embalse NPP

    International Nuclear Information System (INIS)

    Obrutsky, L.S.; Otero, P.A.; Schmidt, O.A.

    1988-01-01

    The design specifications of Embalse Nuclear Power Plants (CANDU Type Reactor 600Mw) define the positions to be taken by 4 separating rings of the fuel channels. Experience has demonstrated the displacement possibility of the above mentioned rings. It means a risk of contact between pressure tube and calandria tube. In order to determine the position of separating rings, an inspection system based on Eddy Currents technique was developed by CNEA personnel. Detection is performed through two special probes operating according the ''emitter-receiver'' principle. Obtained signals and its relative position are recorded in a video tape and registered in paper. The probe is telecommanded by an automatic equipment. In this paper the construction and calibration of the detection equipment is described, as well as the propulsion. Final results are also outlined in the inspection carried out in November 1986 when an effective displacement of separating rings was verified from its design position in most of the inspected tubes

  4. On-line two-dimensional capillary electrophoresis with mass spectrometric detection using a fully electric isolated mechanical valve.

    Science.gov (United States)

    Kohl, Felix J; Montealegre, Cristina; Neusüß, Christian

    2016-04-01

    CE is becoming more and more important in many fields of bioanalytical chemistry. Besides optical detection, hyphenation to ESI-MS detection is increasingly applied for sensitive identification purposes. Unfortunately, many CE techniques and methods established in research and industry are not compatible to ESI-MS since essential components of the background electrolyte interfere in ES ionization. In order to identify unknown peaks in established CE methods, here, a heart-cut 2D-CE separation system is introduced using a fully isolated mechanical valve with an internal loop of only 20 nL. In this system, the sample is separated using potentially any non-ESI compatible method in the first separation dimension. Subsequently, the portion of interest is cut by the internal sample loop of the valve and reintroduced to the second dimension where the interfering compounds are removed, followed by ESI-MS detection. When comparing the separation efficiency of the system with the valve to a system using a continuous capillary only a slight increase in peak width is observed. Ultraviolet/visible detection is integrated in the first dimension for switching time determination, enabling reproducible cutting of peaks of interest. The feasibility of the system is successfully demonstrated by a 2D analysis of a BSA tryptic digest sample using a nonvolatile (phosphate based) background electrolyte in the first dimension. © 2016 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  5. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  6. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    W. Tanis (Wilco); R.P.J. Budde (Ricardo); I.A.C. van der Bilt (Ivo); B. Delemarre; G. Hoohenker; J.-K. Van Rooden; A.M. Scholtens (Asbjørn M.); J. Habets; S.A.J. Chamuleau (Steven)

    2016-01-01

    textabstractProsthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission

  7. Novel imaging strategies for the detection of prosthetic heart valve obstruction and endocarditis

    NARCIS (Netherlands)

    Tanis, W; Budde, R P J; van der Bilt, I A C; Delemarre, B; Hoohenkerk, G; van Rooden, J-K; Scholtens, A M; Habets, J; Chamuleau, S

    Prosthetic heart valve (PHV) dysfunction remains difficult to recognise correctly by two-dimensional (2D) transthoracic and transoesophageal echocardiography (TTE/TEE). ECG-triggered multidetector-row computed tomography (MDCT), 18-fluorine-fluorodesoxyglucose positron emission tomography including

  8. Quantum-capacity-approaching codes for the detected-jump channel

    International Nuclear Information System (INIS)

    Grassl, Markus; Wei Zhaohui; Ji Zhengfeng; Zeng Bei

    2010-01-01

    The quantum-channel capacity gives the ultimate limit for the rate at which quantum data can be reliably transmitted through a noisy quantum channel. Degradable quantum channels are among the few channels whose quantum capacities are known. Given the quantum capacity of a degradable channel, it remains challenging to find a practical coding scheme which approaches capacity. Here we discuss code designs for the detected-jump channel, a degradable channel with practical relevance describing the physics of spontaneous decay of atoms with detected photon emission. We show that this channel can be used to simulate a binary classical channel with both erasures and bit flips. The capacity of the simulated classical channel gives a lower bound on the quantum capacity of the detected-jump channel. When the jump probability is small, it almost equals the quantum capacity. Hence using a classical capacity-approaching code for the simulated classical channel yields a quantum code which approaches the quantum capacity of the detected-jump channel.

  9. Towards an automatic lab-on-valve-ion mobility spectrometric system for detection of cocaine abuse.

    Science.gov (United States)

    Cocovi-Solberg, David J; Esteve-Turrillas, Francesc A; Armenta, Sergio; de la Guardia, Miguel; Miró, Manuel

    2017-08-25

    A lab-on-valve miniaturized system integrating on-line disposable micro-solid phase extraction has been interfaced with ion mobility spectrometry for the accurate and sensitive determination of cocaine and ecgonine methyl ester in oral fluids. The method is based on the automatic loading of 500μL of oral fluid along with the retention of target analytes and matrix clean-up by mixed-mode cationic/reversed-phase solid phase beads, followed by elution with 100μL of 2-propanol containing (3% v/v) ammonia, which are online injected into the IMS. The sorptive particles are automatically discarded after every individual assay inasmuch as the sorptive capacity of the sorbent material is proven to be dramatically deteriorated with reuse. The method provided a limit of detection of 0.3 and 0.14μgL -1 for cocaine and ecgonine methyl ester, respectively, with relative standard deviation values from 8 till 14% with a total analysis time per sample of 7.5min. Method trueness was evaluated by analyzing oral fluid samples spiked with cocaine at different concentration levels (1, 5 and 25μgL -1 ) affording relative recoveries within the range of 85±24%. Fifteen saliva samples were collected from volunteers and analysed following the proposed automatic procedure, showing a 40% cocaine occurrence with concentrations ranging from 1.3 to 97μgL -1 . Field saliva samples were also analysed by reference methods based on lateral flow immunoassay and gas chromatography-mass spectrometry. The application of this procedure to the control of oral fluids of cocaine consumers represents a step forward towards the development of a point-of-care cocaine abuse sensing system. Copyright © 2017 Elsevier B.V. All rights reserved.

  10. MnNi-based spin valve sensors combining high thermal stability, small footprint and pTesla detectivities

    Science.gov (United States)

    Silva, Marília; Leitao, Diana C.; Cardoso, Susana; Freitas, Paulo

    2018-05-01

    Magnetoresistive sensors with high thermal robustness, low noise and high spatial resolution are the answer to a number of challenging applications. Spin valve sensors including MnNi as antiferromagnet layer provide higher exchange bias field and improved thermal stability. In this work, the influence of the buffer layer type (Ta, NiFeCr) and thickness on key sensor parameters (e.g. offset field, Hf) is investigated. A Ta buffer layer promotes a strong (111) texture which leads to a higher value of MR. In contrast, Hf is lower for NiFeCr buffer. Micrometric sensors display thermal noise levels of 1 nT/Hz1/2 and 571 pT/Hz1/2 for a sensor height (h) of 2 and 4 μm, respectively. The temperature dependence of MR and sensitivity is also addressed and compared with MnIr based spin valves. In this case, MR abruptly decreases after heating at 160°C (without magnetic field), contrary to MnNi-based spin valves, where only a 10% MR decrease (relative to the initial value) is seen at 275°C. Finally, to further decrease the noise levels and improve detectivity, MnNi spin-valves are deposited vertically, and connected in parallel and series (in-plane) to create a device with low resistance and high sensitivity. A field detection at thermal level of 346 pT/Hz1/2 is achieved for a device with a total of 300 SVs (4 vertical, 15 in series, 5 in parallel).

  11. Internal leakage detection in control valves; Detektion der inneren Leckage von Stellgeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Kiesbauer, J. [SAMSON AG, Mess- und Regeltechnik, Frankfurt am Main (Germany). Entwicklungspruefstand; Hoffmann, H. [SAMSON AG, Mess- und Regeltechnik, Frankfurt am Main (Germany). Bereich Entwicklung

    2000-07-01

    Digital positioners offer a number of interesting features regarding improved process plant reliability and maintenance or servicing. This can provide the basis for using software tools for early fault diagnosis and performance visualization of control valves with extended functions, such as archiving the control valve's condition when new. It can be subjected to trend analyses as well as to preventative maintenance and servicing while in operation. Up to now, such systems cannot reliably predict the possible increase in internal leakage. Predictions can only be made about a possible change in the actuator's closing force and the zero point when the valve is closed. This article introduces a new and cost-effective leakage detector for control valves in combination with the binary input of a digital positioner which can signal the increase in internal leakage in the throttling area (e.g. caused by wear on the throttling element) of a control valve, if the valve is closed during operation. (orig.) [German] Digitale Stellungsregler bieten eine Reihe von interessanten Moeglichkeiten im Hinblick auf die Verbesserung der Prozesszuverlaessigkeit und der Wartung bzw. Instandhaltung. Auf dieser Basis koennen Softwaretools zur Fehlerfrueherkennung und zur Performance-Visualisierung bei Stellgeraeten mit weitergehender Funktionalitaet eingesetzt werden. Diese unterstuetzen z.B. die Archivierung des Neuzustandes des Stellgeraetes sowie die vorbeugende Wartung und Instandhaltung im laufenden Prozess bis hin zu Trendanalysen. Solche Systeme koennen bisher allerdings noch keine zuverlaessigen Aussagen ueber die eventuelle Zunahme der inneren Leckage machen. Aussagen sind nur moeglich ueber eventuelle Veraenderungen der Antriebsschliesskraft und des Nullpunktes bei geschlossenem Ventil. Dieser Beitrag stellt einen neuartigen kostenguenstigen Leckagedetektor fuer Stellgeraete in Kombination mit dem Binaereingang eines digitalen Stellungsreglers vor, welcher die erhoehte

  12. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  13. Design of Transport Layer Based Hybrid Covert Channel Detection Engine

    OpenAIRE

    K, Anjan; Abraham, Jibi; Jadhav V, Mamatha

    2010-01-01

    Computer network is unpredictable due to information warfare and is prone to various attacks. Such attacks on network compromise the most important attribute, the privacy. Most of such attacks are devised using special communication channel called "Covert Channel". The word "Covert" stands for hidden or non-transparent. Network Covert Channel is a concealed communication path within legitimate network communication that clearly violates security policies laid down. The non-transparency in cov...

  14. Novel imaging strategies for the Detection of Prosthetic Heart Valve Obstruction and Endocarditis

    NARCIS (Netherlands)

    Tanis, W.

    2014-01-01

    Valvular heart disease is accompanied by a high mortality/morbidity and often requires prosthetic heart valve (PHV) replacement in order to improve quality of life and survival. The major drawback of both mechanical and biological PHV implantations is development of dysfunction, which is a life

  15. Early detection of preferential channeling in reverse electrodialysis

    NARCIS (Netherlands)

    Vermaas, David; Saakes, Michel; Nijmeijer, Dorothea C.

    2014-01-01

    Membrane applications often experience fouling, which prevent uniform flow distribution through the feed water compartments, i.e. preferential channeling may occur. This research shows the effect of preferential channeling on energy generation from mixing salt water and fresh water using reverse

  16. Bistable fluidic valve is electrically switched

    Science.gov (United States)

    Fiet, O.; Salvinski, R. J.

    1970-01-01

    Bistable control valve is selectively switched by direct application of an electrical field to divert fluid from one output channel to another. Valve is inexpensive, has no moving parts, and operates on fluids which are relatively poor electrical conductors.

  17. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  18. A cement channel-detection technique using the pulsed-neutron log

    International Nuclear Information System (INIS)

    Myers, G.D.

    1991-01-01

    A channel-detection technique has been developed using boron solutions and pulsed-neutron logging (PNL) tools. This technique relies on the extremely high-neutron-absorption cross section that boron exhibits relative to other common elements, including chlorine. The PNL tool is used to detect movement of a boron solution in a log-inject-log procedure. The technique has identified channels in such difficult applications as logging through two strings of pipe and in highly deviated wellbores. Logging procedures are simple and cement channels can be readily identified. The boron solutions are relatively inexpensive, safe to handle, and nonradioactive. Additional PNL information for reservoir performance evaluation is collected simultaneously during channel-detection logging. This paper describes the theory, development, field application, and limitations of this channel-detection logging technique

  19. Sanshool on The Fingertip Interferes with Vibration Detection in a Rapidly-Adapting (RA Tactile Channel.

    Directory of Open Access Journals (Sweden)

    Scinob Kuroki

    Full Text Available An Asian spice, Szechuan pepper (sanshool, is well known for the tingling sensation it induces on the mouth and on the lips. Electrophysiological studies have revealed that its active ingredient can induce firing of mechanoreceptor fibres that typically respond to mechanical vibration. Moreover, a human behavioral study has reported that the perceived frequency of sanshool-induced tingling matches with the preferred frequency range of the tactile rapidly adapting (RA channel, suggesting the contribution of sanshool-induced RA channel firing to its unique perceptual experience. However, since the RA channel may not be the only channel activated by sanshool, there could be a possibility that the sanshool tingling percept may be caused in whole or in part by other sensory channels. Here, by using a perceptual interference paradigm, we show that the sanshool-induced RA input indeed contributes to the human tactile processing. The absolute detection thresholds for vibrotactile input were measured with and without sanshool application on the fingertip. Sanshool significantly impaired detection of vibrations at 30 Hz (RA channel dominant frequency, but did not impair detection of higher frequency vibrations at 240 Hz (Pacinian-corpuscle (PC channel dominant frequency or lower frequency vibrations at 1 Hz (slowly adapting 1 (SA1 channel dominant frequency. These results show that the sanshool induces a peripheral RA channel activation that is relevant for tactile perception. This anomalous activation of RA channels may contribute to the unique tingling experience of sanshool.

  20. Determination of trace zinc in seawater by coupling solid phase extraction and fluorescence detection in the Lab-On-Valve format.

    Science.gov (United States)

    Grand, Maxime M; Chocholouš, Petr; Růžička, Jarda; Solich, Petr; Measures, Christopher I

    2016-06-07

    By virtue of their compactness, long-term stability, minimal reagent consumption and robustness, miniaturized sequential injection instruments are well suited for automation of assays onboard research ships. However, in order to reach the sensitivity and limit of detection required for open-ocean determinations of trace elements, it is necessary to preconcentrate the analyte prior its derivatization and subsequent detection by fluorescence. In this work, a novel method for the determination of dissolved zinc (Zn) at subnanomolar levels in seawater is described. The proposed method combines, for the first time, automated matrix removal, extraction of the target element, and fluorescence detection within a miniaturized flow manifold, based on the Lab-On-Valve (LOV) concept. The key feature of the microfluidic manipulation of the sample is flow programming, designed to pass sample through a mini-column where the target analyte and other complexable cations are retained, while the seawater matrix is washed out. Next, zinc is eluted and merged with a Zn selective fluorescent probe (FluoZin-3) at the confluence point of the LOV central channel using two high-precision stepper motor driven pumps that are operated in concert. Finally, the thus formed Zn complex is transported to the LOV flow cell for selective fluorescence measurement. This work describes the characterization and optimization of the method including Solid Phase Extraction using the Toyopearl AF-Chelate-650M resin, and detailed assay protocol controlled by a commercially available software and instrument. The proposed method features a LOD of 0.02 nM, high precision (seawater reference standards and comparison with ICP-MS determinations on seawater samples collected in the upper 1300 m of the subtropical south Indian Ocean. This work confirms that integration of sample pretreatment with optical detection in the LOV format offers a widely applicable approach to trace analysis of seawater. Copyright © 2016

  1. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  2. Biomolecule detection using wheatstone bridge giant magnetoresistance (GMR) sensors based on CoFeB spin-valve thin film

    Science.gov (United States)

    Elda Swastika, P.; Antarnusa, G.; Suharyadi, E.; Kato, T.; Iwata, S.

    2018-04-01

    A potential wheatstone bridge giant magnetoresistance (GMR) biosensor have been successfully developed for biomolecule detection. [IrMn(10 nm)/CoFe(3 nm)/Cu(2.2 nm)/CoFeB(10 nm)] spin-valve structure has been chosen as the magnetic sensing surface, showing a magnetoresistance (MR) of 6% fabricated by DC magnetron sputtering method. The Fe3O4 magnetic nanoparticles used as biomolecular labels (nanotags) was synthesized by co-precipitation method, exhibiting soft magnetic behavior with saturation magnetization (Ms), remanent magnetization (Mr) and coercivity (Hc) is 77.2 emu/g, 7.8 emu/g and 51 Oe, respectively. The X-ray diffraction (XRD) patterns and transmission electron microscopy (TEM) images showed that Fe3O4 was well crystallized and grew in their inverse spinel structure, highly uniform morphology with an average grain size was about 20 nm. Fe3O4 was coated with polyethylene-glycol (PEG)-4000 for surface functionalization. Detection of biomolecule such as formalin, gelatin from bovine-skin and porcine-skin were dispersed in ethanol at room temperature. Induction would cause a shift in output voltage with a minimum delta output voltage (ΔV) 4.937 mV (10%) for formalin detection, 2.268 mV (7%) for bovine-skin gelatin and 2.943 mV (7%) for porcine-skin gelatin detection. The ΔV of the wheatstone bridge in real-time measurement decrease by increase in biomolecules concentration. The change of ΔV with various concentration of biomolecule indicates that the spin-valve thin film with wheatstone-bridge circuit is potential as a biosensor.

  3. Advanced Channel Estimation and Multiuser Detection in GSM

    DEFF Research Database (Denmark)

    Arildsen, Thomas; Blauendahl, Jesper

    A single-antenna interference cancellation-capable data detector employing the SAGE-algorithm for GSM downlink transmission with co-channel interference has been designed and tested. Two scenarios were considered: First, a frequency-flat Rayleigh fading scenario with synchronously received users...

  4. Dynamics of ceramide channels detected using a microfluidic system.

    Directory of Open Access Journals (Sweden)

    Chenren Shao

    Full Text Available Ceramide, a proapoptotic sphingolipid, has been shown to form channels, in mitochondrial outer membranes, large enough to translocate proteins. In phospholipid membranes, electrophysiological studies and electron microscopic visualization both report that these channels form in a range of sizes with a modal value of 10 nm in diameter. A hydrogen bonded barrel-like structure consisting of hundreds of ceramide molecules has been proposed for the structure of the channel and this is supported by electrophysiological studies and molecular dynamic simulations. To our knowledge, the mechanical strength and deformability of such a large diameter but extremely thin cylindrical structure has never been reported. Here we present evidence for a reversible mechanical distortion of the cylinder following the addition of La(3+. A microfluidic system was used to repeatedly lower and then restore the conductance by alternatively perfusing La(3+ and EDTA. Although aspects of the kinetics of conductance drop and recovery are consistent with a disassembly/diffusion/reassembly model, others are inconsistent with the expected time scale of lateral diffusion of disassembled channel fragments in the membrane. The presence of a residual conductance following La(3+ treatment and the relationship between the residual conductance and the initial conductance were both indicative of a distortion/recovery process in analogy with a pressure-induced distortion of a flexible cylinder.

  5. Sinus of Valsalva aneurysm and bicuspid aortic valve: detection and mechanism by cardiac magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Jen Li Looi

    2011-09-01

    Full Text Available Cardiac magnetic resonance imaging (CMR demonstrated a sinus of Valsalva aneurysm (SVA with severe dilatation of the right coronary sinus in association with a congenital bicuspid aortic valve (BAV and subaortic membrane. The SVA had not been apparent on echocardiography as the dilatation was outside standard echo image planes. On both CMR and echo, blood flow was eccentrically directed into the right coronary sinus by the domed posterior leaflet of the BAV. The impact of the aortic jet on the wall of the right coronary sinus is probably important in the aetiology of the sinus dilatation. CMR proved valuable in demonstrating the SVA and understanding its aetiology.

  6. Sinus of Valsalva aneurysm and bicuspid aortic valve: detection and mechanism by cardiac magnetic resonance imaging

    Directory of Open Access Journals (Sweden)

    Jen Li Looi

    2011-10-01

    Full Text Available Cardiac magnetic resonance imaging (CMR demonstrated a sinus of Valsalva aneurysm (SVA with severe dilatation of the right coronary sinus in association with a congenital bicuspid aortic valve (BAV and subaortic membrane. The SVA had not been apparent on echocardiography as the dilatation was outside standard echo image planes. On both CMR and echo, blood flow was eccentrically directed into the right coronary sinus by the domed posterior leaflet of the BAV. The impact of the aortic jet on the wall of the right coronary sinus is probably important in the aetiology of the sinus dilatation. CMR proved valuable in demonstrating the SVA and understanding its aetiology.

  7. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  8. Combined diversity and improved energy detection in cooperative spectrum sensing with faded reporting channels

    Directory of Open Access Journals (Sweden)

    Srinivas Nallagonda

    2016-04-01

    Full Text Available In this paper we evaluate the performance of cooperative spectrum sensing (CSS where each cognitive radio (CR employs an improved energy detector (IED with multiple antennas and uses selection combining (SC for detecting the primary user (PU in noisy and faded sensing (S channels. We derive an expression for the probability of false alarm and expressions for probability of missed detection in non-faded (AWGN and Rayleigh faded sensing environments in terms of cumulative distribution function (CDF. Each CR transmits its decision about PU via noisy and faded reporting (R channel to fusion center (FC. In this paper we assume that S-channels are noisy and Rayleigh faded while several cases of fading are considered for R-channels such as: (i Hoyt (or Nakagami-q, (ii Rayleigh, (iii Rician (or Nakagami-n, and (iv Weibull. A Binary Symmetric channel (BSC with a fixed error probability (r in the R-channel is also considered. The impact of fading in R-channel, S-channel and several network parameters such as IED parameter, normalized detection threshold, number of CRs, and number of antennas on missed detection and total error probability is assessed. The effects of Hoyt, Rician, and Weibull fading parameters on overall performance of IED-CSS are also highlighted.

  9. A Network Steganography Lab on Detecting TCP/IP Covert Channels

    Science.gov (United States)

    Zseby, Tanja; Vázquez, Félix Iglesias; Bernhardt, Valentin; Frkat, Davor; Annessi, Robert

    2016-01-01

    This paper presents a network security laboratory to teach data analysis for detecting TCP/IP covert channels. The laboratory is mainly designed for students of electrical engineering, but is open to students of other technical disciplines with similar background. Covert channels provide a method for leaking data from protected systems, which is a…

  10. Sleep Apnoea Detection in Single Channel ECGs by Analyzing Heart Rate Dynamics

    National Research Council Canada - National Science Library

    Zywietz, C

    2001-01-01

    .... Sleep disorders are typically investigated by means of polysomnographic recordings. We have analyzed 70 eight-hour single-channel ECG recordings to find out to which extent sleep apneas may be detected from the ECG alone...

  11. Efficient optimal joint channel estimation and data detection for massive MIMO systems

    KAUST Repository

    Alshamary, Haider Ali Jasim; Xu, Weiyu

    2016-01-01

    show that the expected complexity of our algorithm grows polynomially in the channel coherence time. Simulation results demonstrate significant performance gains of our algorithm compared with suboptimal non-coherent detection algorithms. To the best

  12. An integrative time-varying frequency detection and channel sounding method for dynamic plasma sheath

    Science.gov (United States)

    Shi, Lei; Yao, Bo; Zhao, Lei; Liu, Xiaotong; Yang, Min; Liu, Yanming

    2018-01-01

    The plasma sheath-surrounded hypersonic vehicle is a dynamic and time-varying medium and it is almost impossible to calculate time-varying physical parameters directly. The in-fight detection of the time-varying degree is important to understand the dynamic nature of the physical parameters and their effect on re-entry communication. In this paper, a constant envelope zero autocorrelation (CAZAC) sequence based on time-varying frequency detection and channel sounding method is proposed to detect the plasma sheath electronic density time-varying property and wireless channel characteristic. The proposed method utilizes the CAZAC sequence, which has excellent autocorrelation and spread gain characteristics, to realize dynamic time-varying detection/channel sounding under low signal-to-noise ratio in the plasma sheath environment. Theoretical simulation under a typical time-varying radio channel shows that the proposed method is capable of detecting time-variation frequency up to 200 kHz and can trace the channel amplitude and phase in the time domain well under -10 dB. Experimental results conducted in the RF modulation discharge plasma device verified the time variation detection ability in practical dynamic plasma sheath. Meanwhile, nonlinear phenomenon of dynamic plasma sheath on communication signal is observed thorough channel sounding result.

  13. Minimum Symbol Error Rate Detection in Single-Input Multiple-Output Channels with Markov Noise

    DEFF Research Database (Denmark)

    Christensen, Lars P.B.

    2005-01-01

    Minimum symbol error rate detection in Single-Input Multiple- Output(SIMO) channels with Markov noise is presented. The special case of zero-mean Gauss-Markov noise is examined closer as it only requires knowledge of the second-order moments. In this special case, it is shown that optimal detection...

  14. A parylene-based dual channel microelectrophoresis system for rapid mutation detection via heteroduplex analysis

    NARCIS (Netherlands)

    Sukas, S.; Erson, Ayse Elif; Sert, Cuneyt; Kulah, Haluk

    2008-01-01

    A new dual channel micro-electrophoresis system for rapid mutation detection based on heteroduplex analysis was designed and implemented. Mutation detection was successfully achieved in a total separation length of 250 μm in less than 3 min for a 590 bp DNA sample harboring a 3 bp mutation causing

  15. Efficient optimal joint channel estimation and data detection for massive MIMO systems

    KAUST Repository

    Alshamary, Haider Ali Jasim

    2016-08-15

    In this paper, we propose an efficient optimal joint channel estimation and data detection algorithm for massive MIMO wireless systems. Our algorithm is optimal in terms of the generalized likelihood ratio test (GLRT). For massive MIMO systems, we show that the expected complexity of our algorithm grows polynomially in the channel coherence time. Simulation results demonstrate significant performance gains of our algorithm compared with suboptimal non-coherent detection algorithms. To the best of our knowledge, this is the first algorithm which efficiently achieves GLRT-optimal non-coherent detections for massive MIMO systems with general constellations.

  16. Change detection in multitemporal synthetic aperture radar images using dual-channel convolutional neural network

    Science.gov (United States)

    Liu, Tao; Li, Ying; Cao, Ying; Shen, Qiang

    2017-10-01

    This paper proposes a model of dual-channel convolutional neural network (CNN) that is designed for change detection in SAR images, in an effort to acquire higher detection accuracy and lower misclassification rate. This network model contains two parallel CNN channels, which can extract deep features from two multitemporal SAR images. For comparison and validation, the proposed method is tested along with other change detection algorithms on both simulated SAR images and real-world SAR images captured by different sensors. The experimental results demonstrate that the presented method outperforms the state-of-the-art techniques by a considerable margin.

  17. Applying the J-optimal channelized quadratic observer to SPECT myocardial perfusion defect detection

    Science.gov (United States)

    Kupinski, Meredith K.; Clarkson, Eric; Ghaly, Michael; Frey, Eric C.

    2016-03-01

    To evaluate performance on a perfusion defect detection task from 540 image pairs of myocardial perfusion SPECT image data we apply the J-optimal channelized quadratic observer (J-CQO). We compare AUC values of the linear Hotelling observer and J-CQO when the defect location is fixed and when it occurs in one of two locations. As expected, when the location is fixed a single channels maximizes AUC; location variability requires multiple channels to maximize the AUC. The AUC is estimated from both the projection data and reconstructed images. J-CQO is quadratic since it uses the first- and second- order statistics of the image data from both classes. The linear data reduction by the channels is described by an L x M channel matrix and in prior work we introduced an iterative gradient-based method for calculating the channel matrix. The dimensionality reduction from M measurements to L channels yields better estimates of these sample statistics from smaller sample sizes, and since the channelized covariance matrix is L x L instead of M x M, the matrix inverse is easier to compute. The novelty of our approach is the use of Jeffrey's divergence (J) as the figure of merit (FOM) for optimizing the channel matrix. We previously showed that the J-optimal channels are also the optimum channels for the AUC and the Bhattacharyya distance when the channel outputs are Gaussian distributed with equal means. This work evaluates the use of J as a surrogate FOM (SFOM) for AUC when these statistical conditions are not satisfied.

  18. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  19. Radionuclide esophageal transit test to detect esophageal disorders in patients with mitral valve prolapse

    International Nuclear Information System (INIS)

    Kao Chiahung; Tsai Shihchuan; Hsieh Jihfang; Ho Yungjen; Ding Hueischjy

    2000-01-01

    Aim: The origin of chest discomfort in patients with mitral valve prolapse (MVP) is controversial. Our aim was to prospectively determine the incidence of esophageal disorders in MVP patients with or without chest pain. Methods: Twenty-five MVP patients with chest pain (group A) and 25 MVP patients without chest pain (group B) underwent evaluation of esophageal motility. None of the total of 50 MVP patients had significant coronary artery disease on cardiac catheterization. Esophageal motility including esophageal mean transit time (MTT), residual fraction (RF), and retrograde index (RI) was analyzed by the radionuclide esophageal transit test (RETT). Results: In comparison with 25 age and sex-matched healthy volunteers, the results showed that: (1) 19 patients in group A (76%) had abnormal RETT findings (48% of cases with prolonged MTT, 44% of cases with higher RF, and 60% of cases with higher RI); (2) 3 patients in group B (12%) had abnormal RETT findings (8% of cases with prolonged MTT, 4% of cases with higher RF, and 8% of cases with higher RI). In addition, mean values of MTT, RF, and RI in group A patients were significantly higher than in group B patients and healthy volunteers. Conclusion: We found that the chest pain in some MVP patients may be related to abnormal esophageal motility, based on the evidence from a simple and noninvasive RETT. (orig.) [de

  20. Multiple-channel detection of cellular activities by ion-sensitive transistors

    Science.gov (United States)

    Machida, Satoru; Shimada, Hideto; Motoyama, Yumi

    2018-04-01

    An ion-sensitive field-effect transistor to record cellular activities was demonstrated. This field-effect transistor (bio transistor) includes cultured cells on the gate insulator instead of gate electrode. The bio transistor converts a change in potential underneath the cells into variation of the drain current when ion channels open. The bio transistor has high detection sensitivity to even minute variations in potential utilizing a subthreshold swing region. To open ion channels, a reagent solution (acetylcholine) was added to a human-originating cell cultured on the bio transistor. The drain current was successfully decreased with the addition of acetylcholine. Moreover, we attempted to detect the opening of ion channels using a multiple-channel measurement circuit containing several bio transistors. As a consequence, the drain current distinctly decreased only after the addition of acetylcholine. We confirmed that this measurement system including bio transistors enables to observation of cellular activities sensitively and simultaneously.

  1. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  2. Impact of Channel Estimation Errors on Multiuser Detection via the Replica Method

    Directory of Open Access Journals (Sweden)

    Li Husheng

    2005-01-01

    Full Text Available For practical wireless DS-CDMA systems, channel estimation is imperfect due to noise and interference. In this paper, the impact of channel estimation errors on multiuser detection (MUD is analyzed under the framework of the replica method. System performance is obtained in the large system limit for optimal MUD, linear MUD, and turbo MUD, and is validated by numerical results for finite systems.

  3. Dual-Channel Particle Filter Based Track-Before-Detect for Monopulse Radar

    Directory of Open Access Journals (Sweden)

    Fei Cai

    2014-01-01

    Full Text Available A particle filter based track-before-detect (PF-TBD algorithm is proposed for the monopulse high pulse repetition frequency (PRF pulse Doppler radar. The actual measurement model is adopted, in which the range is highly ambiguous and the sum and difference channels exist in parallel. A quantization method is used to approximate the point spread function to reduce the computation load. The detection decisions of the PF-TBD are fed to a binary integrator to further improve the detection performance. Simulation results show that the proposed algorithm can detect and track the low SNR target efficiently. The detection performance is improved significantly for both the single frame and the multiframe detection compared with the classical detector. A performance comparison with the PF-TBD using sum channel only is also supplied.

  4. Thermo-optical Characterization of Photothermal Optical Phase Shift Detection in Extended-Nano Channels and UV Detection of Biomolecules.

    Science.gov (United States)

    Shimizu, Hisashi; Miyawaki, Naoya; Asano, Yoshihiro; Mawatari, Kazuma; Kitamori, Takehiko

    2017-06-06

    The expansion of microfluidics research to nanofluidics requires absolutely sensitive and universal detection methods. Photothermal detection, which utilizes optical absorption and nonradiative relaxation, is promising for the sensitive detection of nonlabeled biomolecules in nanofluidic channels. We have previously developed a photothermal optical phase shift (POPS) detection method to detect nonfluorescent molecules sensitively, while a rapid decrease of the sensitivity in nanochannels and the introduction of an ultraviolet (UV) excitation system were issues to be addressed. In the present study, our primary aim is to characterize the POPS signal in terms of the thermo-optical properties and quantitatively evaluate the causes for the decrease in sensitivity. The UV excitation system is then introduced into the POPS detector to realize the sensitive detection of nonlabeled biomolecules. The UV-POPS detection system is designed and constructed from scratch based on a symmetric microscope. The results of simulations and experiments reveal that the sensitivity decreases due to a reduction of the detection volume, dissipation of the heat, and cancellation of the changes in the refractive indices. Finally, determination of the concentration of a nonlabeled protein (bovine serum albumin) is performed in a very thin 900 nm deep nanochannel. As a result, the limit of detection (LOD) is 2.3 μM (600 molecules in the 440 attoliter detection volume), which is as low as that previously obtained for our visible POPS detector. UV-POPS detection is thus expected be a powerful technique for the study of biomolecules, including DNAs and proteins confined in nanofluidic channels.

  5. Seizure Onset Detection based on one sEMG channel

    DEFF Research Database (Denmark)

    Conradsen, Isa; Beniczky, Sandor; Hoppe, Karsten

    2011-01-01

    with a Butterworth filter with a cut-off frequency of 150 Hz. The number of zero-crossings with a hysteresis of ±50μV is the only feature extracted. The number of counts in a window of 1 second and the number of windows to make a detection is tested with a leave-one-out method. On 6 patients the method performs...

  6. Comparisons between detection threshold and loudness perception for individual cochlear implant channels

    Science.gov (United States)

    Bierer, Julie Arenberg; Nye, Amberly D

    2014-01-01

    Objective The objective of the present study, performed in cochlear implant listeners, was to examine how the level of current required to detect single-channel electrical pulse trains relates to loudness perception on the same channel. The working hypothesis was that channels with relatively high thresholds, when measured with a focused current pattern, interface poorly to the auditory nerve. For such channels a smaller dynamic range between perceptual threshold and the most comfortable loudness would result, in part, from a greater sensitivity to changes in electrical field spread compared to low-threshold channels. The narrower range of comfortable listening levels may have important implications for speech perception. Design Data were collected from eight, adult cochlear implant listeners implanted with the HiRes90k cochlear implant (Advanced Bionics Corp.). The partial tripolar (pTP) electrode configuration, consisting of one intracochlear active electrode, two flanking electrodes carrying a fraction (σ) of the return current, and an extracochlear ground, was used for stimulation. Single-channel detection thresholds and most comfortable listening levels were acquired using the most focused pTP configuration possible (σ ≥ 0.8) to identify three channels for further testing – those with the highest, median, and lowest thresholds – for each subject. Threshold, equal-loudness contours (at 50% of the monopolar dynamic range), and loudness growth functions were measured for each of these three test channels using various partial tripolar fractions. Results For all test channels, thresholds increased as the electrode configuration became more focused. The rate of increase with the focusing parameter σ was greatest for the high-threshold channel compared to the median- and low-threshold channels. The 50% equal-loudness contours exhibited similar rates of increase in level across test channels and subjects. Additionally, test channels with the highest

  7. In-channel electrochemical detection in the middle of microchannel under high electric field.

    Science.gov (United States)

    Kang, Chung Mu; Joo, Segyeong; Bae, Je Hyun; Kim, Yang-Rae; Kim, Yongseong; Chung, Taek Dong

    2012-01-17

    We propose a new method for performing in-channel electrochemical detection under a high electric field using a polyelectrolytic gel salt bridge (PGSB) integrated in the middle of the electrophoretic separation channel. The finely tuned placement of a gold working electrode and the PGSB on an equipotential surface in the microchannel provided highly sensitive electrochemical detection without any deterioration in the separation efficiency or interference of the applied electric field. To assess the working principle, the open circuit potentials between gold working electrodes and the reference electrode at varying distances were measured in the microchannel under electrophoretic fields using an electrically isolated potentiostat. In addition, "in-channel" cyclic voltammetry confirmed the feasibility of electrochemical detection under various strengths of electric fields (∼400 V/cm). Effective separation on a microchip equipped with a PGSB under high electric fields was demonstrated for the electrochemical detection of biological compounds such as dopamine and catechol. The proposed "in-channel" electrochemical detection under a high electric field enables wider electrochemical detection applications in microchip electrophoresis.

  8. Aggregated channels network for real-time pedestrian detection

    Science.gov (United States)

    Ghorban, Farzin; Marín, Javier; Su, Yu; Colombo, Alessandro; Kummert, Anton

    2018-04-01

    Convolutional neural networks (CNNs) have demonstrated their superiority in numerous computer vision tasks, yet their computational cost results prohibitive for many real-time applications such as pedestrian detection which is usually performed on low-consumption hardware. In order to alleviate this drawback, most strategies focus on using a two-stage cascade approach. Essentially, in the first stage a fast method generates a significant but reduced amount of high quality proposals that later, in the second stage, are evaluated by the CNN. In this work, we propose a novel detection pipeline that further benefits from the two-stage cascade strategy. More concretely, the enriched and subsequently compressed features used in the first stage are reused as the CNN input. As a consequence, a simpler network architecture, adapted for such small input sizes, allows to achieve real-time performance and obtain results close to the state-of-the-art while running significantly faster without the use of GPU. In particular, considering that the proposed pipeline runs in frame rate, the achieved performance is highly competitive. We furthermore demonstrate that the proposed pipeline on itself can serve as an effective proposal generator.

  9. MMSE-based algorithm for joint signal detection, channel and noise variance estimation for OFDM systems

    CERN Document Server

    Savaux, Vincent

    2014-01-01

    This book presents an algorithm for the detection of an orthogonal frequency division multiplexing (OFDM) signal in a cognitive radio context by means of a joint and iterative channel and noise estimation technique. Based on the minimum mean square criterion, it performs an accurate detection of a user in a frequency band, by achieving a quasi-optimal channel and noise variance estimation if the signal is present, and by estimating the noise level in the band if the signal is absent. Organized into three chapters, the first chapter provides the background against which the system model is pr

  10. Multiuser detection and channel estimation: Exact and approximate methods

    DEFF Research Database (Denmark)

    Fabricius, Thomas

    2003-01-01

    subtractive interference cancellation with hyperbolic tangent tentative decision device, in statistical mechanics and machine learning called the naive mean field approach. The differences between the proposed algorithms lie in how the bias is estimated/approximated. We propose approaches based on a second...... propose here to use accurate approximations borrowed from statistical mechanics and machine learning. These give us various algorithms that all can be formulated in a subtractive interference cancellation formalism. The suggested algorithms can e ectively be seen as bias corrections to standard...... of the Junction Tree Algorithm, which is a generalisation of Pearl's Belief Propagation, the BCJR, sum product, min/max sum, and Viterbi's algorithm. Although efficient algoithms, they have an inherent exponential complexity in the number of users when applied to CDMA multiuser detection. For this reason we...

  11. Automatic bad channel detection in intracranial electroencephalographic recordings using ensemble machine learning.

    Science.gov (United States)

    Tuyisenge, Viateur; Trebaul, Lena; Bhattacharjee, Manik; Chanteloup-Forêt, Blandine; Saubat-Guigui, Carole; Mîndruţă, Ioana; Rheims, Sylvain; Maillard, Louis; Kahane, Philippe; Taussig, Delphine; David, Olivier

    2018-03-01

    Intracranial electroencephalographic (iEEG) recordings contain "bad channels", which show non-neuronal signals. Here, we developed a new method that automatically detects iEEG bad channels using machine learning of seven signal features. The features quantified signals' variance, spatial-temporal correlation and nonlinear properties. Because the number of bad channels is usually much lower than the number of good channels, we implemented an ensemble bagging classifier known to be optimal in terms of stability and predictive accuracy for datasets with imbalanced class distributions. This method was applied on stereo-electroencephalographic (SEEG) signals recording during low frequency stimulations performed in 206 patients from 5 clinical centers. We found that the classification accuracy was extremely good: It increased with the number of subjects used to train the classifier and reached a plateau at 99.77% for 110 subjects. The classification performance was thus not impacted by the multicentric nature of data. The proposed method to automatically detect bad channels demonstrated convincing results and can be envisaged to be used on larger datasets for automatic quality control of iEEG data. This is the first method proposed to classify bad channels in iEEG and should allow to improve the data selection when reviewing iEEG signals. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  12. Detection-Guided Fast Affine Projection Channel Estimator for Speech Applications

    Directory of Open Access Journals (Sweden)

    Yan Wu Jennifer

    2007-04-01

    Full Text Available In various adaptive estimation applications, such as acoustic echo cancellation within teleconferencing systems, the input signal is a highly correlated speech. This, in general, leads to extremely slow convergence of the NLMS adaptive FIR estimator. As a result, for such applications, the affine projection algorithm (APA or the low-complexity version, the fast affine projection (FAP algorithm, is commonly employed instead of the NLMS algorithm. In such applications, the signal propagation channel may have a relatively low-dimensional impulse response structure, that is, the number m of active or significant taps within the (discrete-time modelled channel impulse response is much less than the overall tap length n of the channel impulse response. For such cases, we investigate the inclusion of an active-parameter detection-guided concept within the fast affine projection FIR channel estimator. Simulation results indicate that the proposed detection-guided fast affine projection channel estimator has improved convergence speed and has lead to better steady-state performance than the standard fast affine projection channel estimator, especially in the important case of highly correlated speech input signals.

  13. Accurate Sybil Attack Detection Based on Fine-Grained Physical Channel Information

    Directory of Open Access Journals (Sweden)

    Chundong Wang

    2018-03-01

    Full Text Available With the development of the Internet-of-Things (IoT, wireless network security has more and more attention paid to it. The Sybil attack is one of the famous wireless attacks that can forge wireless devices to steal information from clients. These forged devices may constantly attack target access points to crush the wireless network. In this paper, we propose a novel Sybil attack detection based on Channel State Information (CSI. This detection algorithm can tell whether the static devices are Sybil attackers by combining a self-adaptive multiple signal classification algorithm with the Received Signal Strength Indicator (RSSI. Moreover, we develop a novel tracing scheme to cluster the channel characteristics of mobile devices and detect dynamic attackers that change their channel characteristics in an error area. Finally, we experiment on mobile and commercial WiFi devices. Our algorithm can effectively distinguish the Sybil devices. The experimental results show that our Sybil attack detection system achieves high accuracy for both static and dynamic scenarios. Therefore, combining the phase and similarity of channel features, the multi-dimensional analysis of CSI can effectively detect Sybil nodes and improve the security of wireless networks.

  14. Accurate Sybil Attack Detection Based on Fine-Grained Physical Channel Information.

    Science.gov (United States)

    Wang, Chundong; Zhu, Likun; Gong, Liangyi; Zhao, Zhentang; Yang, Lei; Liu, Zheli; Cheng, Xiaochun

    2018-03-15

    With the development of the Internet-of-Things (IoT), wireless network security has more and more attention paid to it. The Sybil attack is one of the famous wireless attacks that can forge wireless devices to steal information from clients. These forged devices may constantly attack target access points to crush the wireless network. In this paper, we propose a novel Sybil attack detection based on Channel State Information (CSI). This detection algorithm can tell whether the static devices are Sybil attackers by combining a self-adaptive multiple signal classification algorithm with the Received Signal Strength Indicator (RSSI). Moreover, we develop a novel tracing scheme to cluster the channel characteristics of mobile devices and detect dynamic attackers that change their channel characteristics in an error area. Finally, we experiment on mobile and commercial WiFi devices. Our algorithm can effectively distinguish the Sybil devices. The experimental results show that our Sybil attack detection system achieves high accuracy for both static and dynamic scenarios. Therefore, combining the phase and similarity of channel features, the multi-dimensional analysis of CSI can effectively detect Sybil nodes and improve the security of wireless networks.

  15. Detection of a random signal in a multi-channel environment: a performance study

    International Nuclear Information System (INIS)

    Frenzel, K.Z.

    1986-01-01

    Performance of the optimal (likelihood ratio) test and suboptimal tests, including the normalized cross correlator and two energy detectors are compared for problems involving non-gaussian as well as gaussian statistics. Also, optimal one-channel processing is compared to optimal two-channel processing for equivalent total signal-to-noise ratios. Receiver operator characteristics (ROC) curves obtained by a combination of simulation and analytic methods are used to evaluate the performance of the processors. It was found that two-channel processing helps the detection performance the most when the noise levels are uncertain. This was true for all signal and noise densities studied. In cases where the noise levels and channel attenuations are known, or when only the attenuations are uncertain, the performance using optimal one-channel processing was close to that found using optimal two-channel processing. When comparing optimal processors to the three suboptimal processors, it was found that when the noise level in each channel is very uncertain, the performance of the normalized cross correlator is much closer to the optimal than that of either of the energy detectors. If, however, the noise levels are know with a fair degree of certainty, the performance of the energy detectors improves considerably, in some cases approaching the optimal performance

  16. System and method for detecting components of a mixture including a valving scheme for competition assays

    Energy Technology Data Exchange (ETDEWEB)

    Koh, Chung-Yan; Piccini, Matthew E.; Singh, Anup K.

    2017-09-19

    Examples are described including measurement systems for conducting competition assays. A first chamber of an assay device may be loaded with a sample containing a target antigen. The target antigen in the sample may be allowed to bind to antibody-coated beads in the first chamber. A control layer separating the first chamber from a second chamber may then be opened to allow a labeling agent loaded in a first portion of the second chamber to bind to any unoccupied sites on the antibodies. A centrifugal force may then be applied to transport the beads through a density media to a detection region for measurement by a detection unit.

  17. System and method for detecting components of a mixture including a valving scheme for competition assays

    Science.gov (United States)

    Koh, Chung-Yan; Piccini, Matthew E.; Singh, Anup K.

    2017-07-11

    Examples are described including measurement systems for conducting competition assays. A first chamber of an assay device may be loaded with a sample containing a target antigen. The target antigen in the sample may be allowed to bind to antibody-coated beads in the first chamber. A control layer separating the first chamber from a second chamber may then be opened to allow a labeling agent loaded in a first portion of the second chamber to bind to any unoccupied sites on the antibodies. A centrifugal force may then be applied to transport the beads through a density media to a detection region for measurement by a detection unit.

  18. Use of multidetector-row computed tomography scan to detect pannus formation in prosthetic mechanical aortic valves.

    Science.gov (United States)

    Aladmawi, Mohamed A; Pragliola, Claudio; Vriz, Olga; Galzerano, Domenico

    2017-04-01

    Obstruction of a mechanical aortic valve by pannus formation at the subvalvular level is a major long-term complication of aortic valve replacement (AVR). In fact, pannus is sometime difficult to differentiate from patient-prosthesis mismatch or valve thrombosis. In most cases cine-angiography and echocardiography, either transthoracic or transesophageal, cannot correctly visualize the complication when the leaflets show a normal mobility. Recent technological refinements made this difficult diagnosis possible by ECG-gated computed tomography (CT) scan which shows adequate images in 90% of the cases and can differentiate pannus from fresh and organized thrombus.

  19. Low Complexity Iterative Joint Channel Estimation and Multiuser Detection for DS-CDMA

    DEFF Research Database (Denmark)

    Christensen, Søren Skovgård; Kocian, Alexander; Fleury, Bernard Henri

    2004-01-01

    Previously the SAGE algorithm was applied to sub-optimal yet efficient Joint data Detection and channel Estimation (JDE) for DS-CDMA of moderate time complexity. Modifying the expectation and maximization steps of the SAGE-JDE scheme, it is possible to obtain an efficient receiver architecture...

  20. Imaging of underground karst water channels using an improved multichannel transient Rayleigh wave detecting method.

    Science.gov (United States)

    Zheng, Xuhui; Liu, Lei; Sun, Jinzhong; Li, Gao; Zhou, Fubiao; Xu, Jiemin

    2018-01-01

    Geological and hydrogeological conditions in karst areas are complicated from the viewpoint of engineering. The construction of underground structures in these areas is often disturbed by the gushing of karst water, which may delay the construction schedule, result in economic losses, and even cause heavy casualties. In this paper, an innovative method of multichannel transient Rayleigh wave detecting is proposed by introducing the concept of arrival time difference phase between channels (TDP). Overcoming the restriction of the space-sampling law, the proposed method can extract the phase velocities of different frequency components from only two channels of transient Rayleigh wave recorded on two adjacent detecting points. This feature greatly improves the work efficiency and lateral resolution of transient Rayleigh wave detecting. The improved multichannel transient Rayleigh wave detecting method is applied to the detection of karst caves and fractures in rock mass of the foundation pit of Yan'an Road Station of Guiyang Metro. The imaging of the detecting results clearly reveals the distribution of karst water inflow channels, which provided significant guidance for water plugging and enabled good control over karst water gushing in the foundation pit.

  1. A novel reduced-complexity group detection structure in MIMO frequency selective fading channels

    KAUST Repository

    Qaraqe, Khalid A.; Ahimian, Nariman R.; Alouini, Mohamed-Slim

    2010-01-01

    In this paper a novel reduced complexity detection method named modified symbol flipping method is introduced and its advantages on reducing the burden of the calculations at the receiver compared to the optimum maximum likelihood detection method on multiple input- multiple output frequency selective fading channels are explained. The initial concept of the symbol flipping method is derived from a preliminary detection scheme named bit flipping which was introduced in [1]. The detection structure employed in this paper is ing, detection, and cancellation. On the detection stage, the proposed method is employed and the results are compared to the group maximum likelihood detection scheme proposed in [2]. Simulation results show that a 6 dB performance gain can be achieved at the expense of a slight increase in complexity in comparison with the conventional symbol flipping scheme. © 2010 Crown.

  2. A novel reduced-complexity group detection structure in MIMO frequency selective fading channels

    KAUST Repository

    Qaraqe, Khalid A.

    2010-09-01

    In this paper a novel reduced complexity detection method named modified symbol flipping method is introduced and its advantages on reducing the burden of the calculations at the receiver compared to the optimum maximum likelihood detection method on multiple input- multiple output frequency selective fading channels are explained. The initial concept of the symbol flipping method is derived from a preliminary detection scheme named bit flipping which was introduced in [1]. The detection structure employed in this paper is ing, detection, and cancellation. On the detection stage, the proposed method is employed and the results are compared to the group maximum likelihood detection scheme proposed in [2]. Simulation results show that a 6 dB performance gain can be achieved at the expense of a slight increase in complexity in comparison with the conventional symbol flipping scheme. © 2010 Crown.

  3. A Wearable Channel Selection-Based Brain-Computer Interface for Motor Imagery Detection.

    Science.gov (United States)

    Lo, Chi-Chun; Chien, Tsung-Yi; Chen, Yu-Chun; Tsai, Shang-Ho; Fang, Wai-Chi; Lin, Bor-Shyh

    2016-02-06

    Motor imagery-based brain-computer interface (BCI) is a communication interface between an external machine and the brain. Many kinds of spatial filters are used in BCIs to enhance the electroencephalography (EEG) features related to motor imagery. The approach of channel selection, developed to reserve meaningful EEG channels, is also an important technique for the development of BCIs. However, current BCI systems require a conventional EEG machine and EEG electrodes with conductive gel to acquire multi-channel EEG signals and then transmit these EEG signals to the back-end computer to perform the approach of channel selection. This reduces the convenience of use in daily life and increases the limitations of BCI applications. In order to improve the above issues, a novel wearable channel selection-based brain-computer interface is proposed. Here, retractable comb-shaped active dry electrodes are designed to measure the EEG signals on a hairy site, without conductive gel. By the design of analog CAR spatial filters and the firmware of EEG acquisition module, the function of spatial filters could be performed without any calculation, and channel selection could be performed in the front-end device to improve the practicability of detecting motor imagery in the wearable EEG device directly or in commercial mobile phones or tablets, which may have relatively low system specifications. Finally, the performance of the proposed BCI is investigated, and the experimental results show that the proposed system is a good wearable BCI system prototype.

  4. Comparison of Different Features and Classifiers for Driver Fatigue Detection Based on a Single EEG Channel

    Directory of Open Access Journals (Sweden)

    Jianfeng Hu

    2017-01-01

    Full Text Available Driver fatigue has become an important factor to traffic accidents worldwide, and effective detection of driver fatigue has major significance for public health. The purpose method employs entropy measures for feature extraction from a single electroencephalogram (EEG channel. Four types of entropies measures, sample entropy (SE, fuzzy entropy (FE, approximate entropy (AE, and spectral entropy (PE, were deployed for the analysis of original EEG signal and compared by ten state-of-the-art classifiers. Results indicate that optimal performance of single channel is achieved using a combination of channel CP4, feature FE, and classifier Random Forest (RF. The highest accuracy can be up to 96.6%, which has been able to meet the needs of real applications. The best combination of channel + features + classifier is subject-specific. In this work, the accuracy of FE as the feature is far greater than the Acc of other features. The accuracy using classifier RF is the best, while that of classifier SVM with linear kernel is the worst. The impact of channel selection on the Acc is larger. The performance of various channels is very different.

  5. DETECTING AND CORRECTING MOTION BLUR FROM IMAGES SHOT WITH CHANNEL-DEPENDENT EXPOSURE TIME

    Directory of Open Access Journals (Sweden)

    L. Lelégard

    2012-07-01

    Full Text Available This article describes a pipeline developed to automatically detect and correct motion blur due to the airplane motion in aerial images provided by a digital camera system with channel-dependent exposure times. Blurred images show anisotropy in their Fourier Transform coefficients that can be detected and estimated to recover the characteristics of the motion blur. To disambiguate the anisotropy produced by a motion blur from the possible spectral anisotropy produced by some periodic patterns present in a sharp image, we consider the phase difference of the Fourier Transform of two channel shot with different exposure times (i.e. with different blur extensions. This is possible because of the deep correlation between the three visible channels ensures phase coherence of the Fourier Transform coefficients in sharp images. In this context, considering the phase difference constitutes both a good detector and estimator of the motion blur parameters. In order to improve on this estimation, the phase difference is performed on local windows in the image where the channels are more correlated. The main lobe of the phase difference, where the phase difference between two channels is close to zero actually imitates an ellipse which axis ratio discriminates blur and which orientation and minor axis give respectively the orientation and the blur kernel extension of the long exposure-time channels. However, this approach is not robust to the presence in the phase difference of minor lobes due to phase sign inversions in the Fourier transform of the motion blur. They are removed by considering the polar representation of the phase difference. Based on the blur detection step, blur correction is eventually performed using two different approaches depending on the blur extension size: using either a simple frequency-based fusion for small blur or a semi blind iterative method for larger blur. The higher computing costs of the latter method make it only

  6. Equalization and detection for digital communication over nonlinear bandlimited satellite communication channels. Ph.D. Thesis

    Science.gov (United States)

    Gutierrez, Alberto, Jr.

    1995-01-01

    This dissertation evaluates receiver-based methods for mitigating the effects due to nonlinear bandlimited signal distortion present in high data rate satellite channels. The effects of the nonlinear bandlimited distortion is illustrated for digitally modulated signals. A lucid development of the low-pass Volterra discrete time model for a nonlinear communication channel is presented. In addition, finite-state machine models are explicitly developed for a nonlinear bandlimited satellite channel. A nonlinear fixed equalizer based on Volterra series has previously been studied for compensation of noiseless signal distortion due to a nonlinear satellite channel. This dissertation studies adaptive Volterra equalizers on a downlink-limited nonlinear bandlimited satellite channel. We employ as figure of merits performance in the mean-square error and probability of error senses. In addition, a receiver consisting of a fractionally-spaced equalizer (FSE) followed by a Volterra equalizer (FSE-Volterra) is found to give improvement beyond that gained by the Volterra equalizer. Significant probability of error performance improvement is found for multilevel modulation schemes. Also, it is found that probability of error improvement is more significant for modulation schemes, constant amplitude and multilevel, which require higher signal to noise ratios (i.e., higher modulation orders) for reliable operation. The maximum likelihood sequence detection (MLSD) receiver for a nonlinear satellite channel, a bank of matched filters followed by a Viterbi detector, serves as a probability of error lower bound for the Volterra and FSE-Volterra equalizers. However, this receiver has not been evaluated for a specific satellite channel. In this work, an MLSD receiver is evaluated for a specific downlink-limited satellite channel. Because of the bank of matched filters, the MLSD receiver may be high in complexity. Consequently, the probability of error performance of a more practical

  7. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  8. Channel noise enhances signal detectability in a model of acoustic neuron through the stochastic resonance paradigm.

    Science.gov (United States)

    Liberti, M; Paffi, A; Maggio, F; De Angelis, A; Apollonio, F; d'Inzeo, G

    2009-01-01

    A number of experimental investigations have evidenced the extraordinary sensitivity of neuronal cells to weak input stimulations, including electromagnetic (EM) fields. Moreover, it has been shown that biological noise, due to random channels gating, acts as a tuning factor in neuronal processing, according to the stochastic resonant (SR) paradigm. In this work the attention is focused on noise arising from the stochastic gating of ionic channels in a model of Ranvier node of acoustic fibers. The small number of channels gives rise to a high noise level, which is able to cause a spike train generation even in the absence of stimulations. A SR behavior has been observed in the model for the detection of sinusoidal signals at frequencies typical of the speech.

  9. Combined Dust Detection Algorithm by Using MODIS Infrared Channels over East Asia

    Science.gov (United States)

    Park, Sang Seo; Kim, Jhoon; Lee, Jaehwa; Lee, Sukjo; Kim, Jeong Soo; Chang, Lim Seok; Ou, Steve

    2014-01-01

    A new dust detection algorithm is developed by combining the results of multiple dust detectionmethods using IR channels onboard the MODerate resolution Imaging Spectroradiometer (MODIS). Brightness Temperature Difference (BTD) between two wavelength channels has been used widely in previous dust detection methods. However, BTDmethods have limitations in identifying the offset values of the BTDto discriminate clear-sky areas. The current algorithm overcomes the disadvantages of previous dust detection methods by considering the Brightness Temperature Ratio (BTR) values of the dual wavelength channels with 30-day composite, the optical properties of the dust particles, the variability of surface properties, and the cloud contamination. Therefore, the current algorithm shows improvements in detecting the dust loaded region over land during daytime. Finally, the confidence index of the current dust algorithm is shown in 10 × 10 pixels of the MODIS observations. From January to June, 2006, the results of the current algorithm are within 64 to 81% of those found using the fine mode fraction (FMF) and aerosol index (AI) from the MODIS and Ozone Monitoring Instrument (OMI). The agreement between the results of the current algorithm and the OMI AI over the non-polluted land also ranges from 60 to 67% to avoid errors due to the anthropogenic aerosol. In addition, the developed algorithm shows statistically significant results at four AErosol RObotic NETwork (AERONET) sites in East Asia.

  10. Spin-resolved electron waiting times in a quantum-dot spin valve

    Science.gov (United States)

    Tang, Gaomin; Xu, Fuming; Mi, Shuo; Wang, Jian

    2018-04-01

    We study the electronic waiting-time distributions (WTDs) in a noninteracting quantum-dot spin valve by varying spin polarization and the noncollinear angle between the magnetizations of the leads using the scattering matrix approach. Since the quantum-dot spin valve involves two channels (spin up and down) in both the incoming and outgoing channels, we study three different kinds of WTDs, which are two-channel WTD, spin-resolved single-channel WTD, and cross-channel WTD. We analyze the behaviors of WTDs in short times, correlated with the current behaviors for different spin polarizations and noncollinear angles. Cross-channel WTD reflects the correlation between two spin channels and can be used to characterize the spin-transfer torque process. We study the influence of the earlier detection on the subsequent detection from the perspective of cross-channel WTD, and define the influence degree quantity as the cumulative absolute difference between cross-channel WTDs and first-passage time distributions to quantitatively characterize the spin-flip process. We observe that influence degree versus spin-transfer torque for different noncollinear angles as well as different polarizations collapse into a single curve showing universal behaviors. This demonstrates that cross-channel WTDs can be a pathway to characterize spin correlation in spintronics system.

  11. Microwave frequency sensor for detection of biological cells in microfluidic channels.

    Science.gov (United States)

    Nikolic-Jaric, M; Romanuik, S F; Ferrier, G A; Bridges, G E; Butler, M; Sunley, K; Thomson, D J; Freeman, M R

    2009-08-12

    We present details of an apparatus for capacitive detection of biomaterials in microfluidic channels operating at microwave frequencies where dielectric effects due to interfacial polarization are minimal. A circuit model is presented, which can be used to adapt this detection system for use in other microfluidic applications and to identify ones where it would not be suitable. The detection system is based on a microwave coupled transmission line resonator integrated into an interferometer. At 1.5 GHz the system is capable of detecting changes in capacitance of 650 zF with a 50 Hz bandwidth. This system is well suited to the detection of biomaterials in a variety of suspending fluids, including phosphate-buffered saline. Applications involving both model particles (polystyrene microspheres) and living cells-baker's yeast (Saccharomyces cerevisiae) and Chinese hamster ovary cells-are presented.

  12. 32-Channel banana-avg montage is better than 16-channel double banana montage to detect epileptiform discharges in routine EEGs.

    Science.gov (United States)

    Ochoa, Juan; Gonzalez, Walter; Bautista, Ramon; DeCerce, John

    2008-10-01

    We designed a study, comparing the yield of standard 16-channel longitudinal bipolar montage (double banana) versus a combined 32-channel longitudinal bipolar plus average referential montage (banana-plus), to detect epileptic abnormalities. We selected 25 consecutive routine EEG samples with a diagnosis of spike or sharp waves in the temporal regions and 25 consecutive focal slowing and 50 normal EEGs. A total of 100 samples were printed in both montages and randomized for reading. Thirty independent EEG readers blinded from the EEG diagnosis were invited to participate. Twenty-two readers successfully completed the test for a total of 4400 answers collected for analysis. The average sensitivity to detect epileptiform discharges for 16 and 32-channel montages was 36.5% and 61%, respectively (Pdouble banana montage. Residents and EEG fellows could improve EEG-reading accuracy if taught on a combined 32-channel montage.

  13. Detect-and-forward in two-hop relay channels: a metrics-based analysis

    KAUST Repository

    Benjillali, Mustapha

    2010-06-01

    In this paper, we analyze the coded performance of a cooperative system with multiple parallel relays using "Detect-and-Forward" (DetF) strategy where each relay demodulates the overheard signal and forwards the detected binary words. The proposed method is based on the probabilistic characterization of the reliability metrics given under the form of L-values. First, we derive analytical expressions of the probability density functions (PDFs) of the L-values in the elementary two-hop DetF relay channel with different source-relay channel state information assumptions. Then, we apply the obtained expressions to calculate the theoretically achievable rates and compare them with the practical throughput of a simulated turbo-coded transmission. Next, we derive tight approximations for the end-to-end coded bit error rate (BER) of a general cooperative scheme with multiple parallel relays. Simulation results demonstrate the accuracy of our derivations for different cooperation configurations and conditions. © 2010 IEEE.

  14. Radiographic detection of single-leg fracture in Björk-Shiley Convexo-Concave prosthetic valves: a phantom model study.

    Science.gov (United States)

    Gilchrist, I C; Cardella, J F; Fox, P S; Pae, W E; el-Ghamry Sabe, A A; Landis, J R; Localio, A R; Kunselman, A R; Hopper, K D

    1997-02-01

    Cineradiography can identify patients with single-leg fractured Björk-Shiley Convexo-Concave valves, although little is known about the sensitivity and specificity of this technique. We evaluated three normal and six (0 microm gap) single-leg fractured Björk-Shiley valves that were placed in a working phantom model. Valves were randomly imaged a total of 33 times and duplicated into a 120-valve series with a 1:9 ratio of abnormal/normal valves. Six reviewers independently graded each valve and demonstrated markedly different rates of identifying the fractured valves. Average sensitivity at the grade that clinically results in valve explanation was 47%. Among the normal valves, a correct identification was made 96% (range 91% to 99%) of the time. Present radiographic technology may have significant difficulty in identifying true single-leg fracture in Björk-Shiley valves with limb separations that are common among clinically explanted valves.

  15. Microfluidic CODES: a scalable multiplexed electronic sensor for orthogonal detection of particles in microfluidic channels.

    Science.gov (United States)

    Liu, Ruxiu; Wang, Ningquan; Kamili, Farhan; Sarioglu, A Fatih

    2016-04-21

    Numerous biophysical and biochemical assays rely on spatial manipulation of particles/cells as they are processed on lab-on-a-chip devices. Analysis of spatially distributed particles on these devices typically requires microscopy negating the cost and size advantages of microfluidic assays. In this paper, we introduce a scalable electronic sensor technology, called microfluidic CODES, that utilizes resistive pulse sensing to orthogonally detect particles in multiple microfluidic channels from a single electrical output. Combining the techniques from telecommunications and microfluidics, we route three coplanar electrodes on a glass substrate to create multiple Coulter counters producing distinct orthogonal digital codes when they detect particles. We specifically design a digital code set using the mathematical principles of Code Division Multiple Access (CDMA) telecommunication networks and can decode signals from different microfluidic channels with >90% accuracy through computation even if these signals overlap. As a proof of principle, we use this technology to detect human ovarian cancer cells in four different microfluidic channels fabricated using soft lithography. Microfluidic CODES offers a simple, all-electronic interface that is well suited to create integrated, low-cost lab-on-a-chip devices for cell- or particle-based assays in resource-limited settings.

  16. Scene text detection by leveraging multi-channel information and local context

    Science.gov (United States)

    Wang, Runmin; Qian, Shengyou; Yang, Jianfeng; Gao, Changxin

    2018-03-01

    As an important information carrier, texts play significant roles in many applications. However, text detection in unconstrained scenes is a challenging problem due to cluttered backgrounds, various appearances, uneven illumination, etc.. In this paper, an approach based on multi-channel information and local context is proposed to detect texts in natural scenes. According to character candidate detection plays a vital role in text detection system, Maximally Stable Extremal Regions(MSERs) and Graph-cut based method are integrated to obtain the character candidates by leveraging the multi-channel image information. A cascaded false positive elimination mechanism are constructed from the perspective of the character and the text line respectively. Since the local context information is very valuable for us, these information is utilized to retrieve the missing characters for boosting the text detection performance. Experimental results on two benchmark datasets, i.e., the ICDAR 2011 dataset and the ICDAR 2013 dataset, demonstrate that the proposed method have achieved the state-of-the-art performance.

  17. A Detection Algorithm for the BOC Signal Based on Quadrature Channel Correlation

    Directory of Open Access Journals (Sweden)

    Bo Qian

    2018-01-01

    Full Text Available In order to solve the problem of detecting a BOC signal, which uses a long-period pseudo random sequence, an algorithm is presented based on quadrature channel correlation. The quadrature channel correlation method eliminates the autocorrelation component of the carrier wave, allowing for the extraction of the absolute autocorrelation peaks of the BOC sequence. If the same lag difference and height difference exist for the adjacent peaks, the BOC signal can be detected effectively using a statistical analysis of the multiple autocorrelation peaks. The simulation results show that the interference of the carrier wave component is eliminated and the autocorrelation peaks of the BOC sequence are obtained effectively without demodulation. The BOC signal can be detected effectively when the SNR is greater than −12 dB. The detection ability can be improved further by increasing the number of sampling points. The higher the ratio of the square wave subcarrier speed to the pseudo random sequence speed is, the greater the detection ability is with a lower SNR. The algorithm presented in this paper is superior to the algorithm based on the spectral correlation.

  18. Multi-Channel Amplifier-Discriminator for Highly Time-Resolved Detection

    CERN Document Server

    Despeisse, M; Lapington, J; Jarron, P

    2011-01-01

    A low-power multi-channel amplifier-discriminator was developed for application in highly time-resolved detection systems. The proposed circuit architecture, so-called Nino, is based on a time-over-threshold approach and shows a high potential for time-resolved readout of solid-state photo-detectors and of detectors based on vacuum technologies. The Irpics circuit was designed in a 250 nm CMOS technology, implementing 32 channels of a Nino version optimized to achieve high-time resolution on the output low-voltage differential signals (LVDS) while keeping a low power consumption of 10 mW per channel. Electrical characterizations of the circuit demonstrate a very low intrinsic time jitter on the output pulse leading edge, measured below 10 ps rms for each channel for high input signal charges (100 fC) and below 25 ps rms for low input signal charges (20-100 fC). The read-out architecture moreover permits to retrieve the input signal charge from the timing measurements, while a calibration procedure was develop...

  19. Multi-channel integrated circuits for the detection and measurement of ionizing radiation

    International Nuclear Information System (INIS)

    Engel, G.L.; Duggireddi, N.; Vangapally, V.; Elson, J.M.; Sobotka, L.G.; Charity, R.J.

    2011-01-01

    The Integrated Circuits (IC) Design Research Laboratory at Southern Illinois University Edwardsville (SIUE) has collaborated with the Nuclear Reactions Group at Washington University (WU) to develop a family of multi-channel integrated circuits. To date, the collaboration has successfully produced two micro-chips. The first was an analog shaped and peak sensing chip with on-board constant-fraction discriminators and sparsified readout. This chip is known as Heavy-Ion Nuclear Physics-16 Channel (HINP16C). The second chip, christened PSD8C, was designed to logically complement (in terms of detector types) the HINP16C chip. Pulse Shape Discrimination-8 Channel (PSD8C), featuring three settable charge integration windows per channel, performs pulse shape discrimination (PSD). This paper summarizes the design, capabilities, and features of the HINP16C and PSD8C ICs. It proceeds to discuss the modifications, made to the ICs and their associated systems, which have attempted to improve ease of use, increase performance, and extend capabilities. The paper concludes with a brief discussion of what may be the next chip (employing a multi-sampling scheme) to be added to our CMOS ASIC 'tool box' for radiation detection instrumentation.

  20. Tuning Piezo ion channels to detect molecular-scale movements relevant for fine touch

    Science.gov (United States)

    Poole, Kate; Herget, Regina; Lapatsina, Liudmila; Ngo, Ha-Duong; Lewin, Gary R.

    2014-01-01

    In sensory neurons, mechanotransduction is sensitive, fast and requires mechanosensitive ion channels. Here we develop a new method to directly monitor mechanotransduction at defined regions of the cell-substrate interface. We show that molecular-scale (~13 nm) displacements are sufficient to gate mechanosensitive currents in mouse touch receptors. Using neurons from knockout mice, we show that displacement thresholds increase by one order of magnitude in the absence of stomatin-like protein 3 (STOML3). Piezo1 is the founding member of a class of mammalian stretch-activated ion channels, and we show that STOML3, but not other stomatin-domain proteins, brings the activation threshold for Piezo1 and Piezo2 currents down to ~10 nm. Structure–function experiments localize the Piezo modulatory activity of STOML3 to the stomatin domain, and higher-order scaffolds are a prerequisite for function. STOML3 is the first potent modulator of Piezo channels that tunes the sensitivity of mechanically gated channels to detect molecular-scale stimuli relevant for fine touch. PMID:24662763

  1. Maximum-Likelihood Sequence Detection of Multiple Antenna Systems over Dispersive Channels via Sphere Decoding

    Directory of Open Access Journals (Sweden)

    Hassibi Babak

    2002-01-01

    Full Text Available Multiple antenna systems are capable of providing high data rate transmissions over wireless channels. When the channels are dispersive, the signal at each receive antenna is a combination of both the current and past symbols sent from all transmit antennas corrupted by noise. The optimal receiver is a maximum-likelihood sequence detector and is often considered to be practically infeasible due to high computational complexity (exponential in number of antennas and channel memory. Therefore, in practice, one often settles for a less complex suboptimal receiver structure, typically with an equalizer meant to suppress both the intersymbol and interuser interference, followed by the decoder. We propose a sphere decoding for the sequence detection in multiple antenna communication systems over dispersive channels. The sphere decoding provides the maximum-likelihood estimate with computational complexity comparable to the standard space-time decision-feedback equalizing (DFE algorithms. The performance and complexity of the sphere decoding are compared with the DFE algorithm by means of simulations.

  2. Sexy DEG/ENaC channels involved in gustatory detection of fruit fly pheromones.

    Science.gov (United States)

    Pikielny, Claudio W

    2012-11-06

    Hydrocarbon pheromones on the cuticle of Drosophila melanogaster modulate the complex courtship behavior of males. Recently, three members of the degenerin/epithelial Na+ channel (DEG/ENaC) family of sodium channel subunits, Ppk25, Ppk23, and Ppk29 (also known as Nope), have been shown to function in gustatory perception of courtship-modulating contact pheromones. All three proteins are required for the activation of male courtship by female pheromones. Specific interactions between two of them have been demonstrated in cultured cells, suggesting that, in a subset of cells where they are coexpressed, these three subunits function within a common heterotrimeric DEG/ENaC channel. Such a DEG/ENaC channel may be gated by pheromones, either directly or indirectly, or alternatively may control the excitability of pheromone-sensing cells. In addition, these studies identify taste neurons that respond specifically to courtship-modulating pheromones and mediate their effects on male behavior. Two types of pheromone-sensing taste neurons, F and M cells, have been defined on the basis of their specific response to either female or male pheromones. These reports set the stage for the dissection of the molecular and cellular mechanisms that mediate gustatory detection of contact pheromones.

  3. Extended Kalman Filter Channel Estimation for Line-of-Sight Detection in WCDMA Mobile Positioning

    Directory of Open Access Journals (Sweden)

    Abdelmonaem Lakhzouri

    2003-12-01

    Full Text Available In mobile positioning, it is very important to estimate correctly the delay between the transmitter and the receiver. When the receiver is in line-of-sight (LOS condition with the transmitter, the computation of the mobile position in two dimensions becomes straightforward. In this paper, the problem of LOS detection in WCDMA for mobile positioning is considered, together with joint estimation of the delays and channel coefficients. These are very challenging topics in multipath fading channels because LOS component is not always present, and when it is present, it might be severely affected by interfering paths spaced at less than one chip distance (closely spaced paths. The extended Kalman filter (EKF is used to estimate jointly the delays and complex channel coefficients. The decision whether the LOS component is present or not is based on statistical tests to determine the distribution of the channel coefficient corresponding to the first path. The statistical test-based techniques are practical, simple, and of low computation complexity, which is suitable for WCDMA receivers. These techniques can provide an accurate decision whether LOS component is present or not.

  4. Strain detection in crystalline heterostructures using bidimensional blocking patterns of channelled particles

    Science.gov (United States)

    Redondo-Cubero, A.; David-Bosne, E.; Wahl, U.; Miranda, P.; da Silva, M. R.; Correia, J. G.; Lorenz, K.

    2018-03-01

    Strain is a critical parameter affecting the growth and the performance of many semiconductor systems but, at the same time, the accurate determination of strain profiles in heterostructures can be challenging, especially at the nanoscale. Ion channelling/blocking is a powerful technique for the detection of the strain state of thin films, normally carried out through angular scans with conventional particle detectors. Here we report the novel application of position sensitive detectors for the evaluation of the strain in a series of AlInN/GaN heterostructures with different compositions and thicknesses. The tetragonal strain is varied from compressive to tensile and analysed through bidimensional blocking patterns. The results demonstrate that strain can be correctly quantified when compared to Monte Carlo channelling simulations, which are essential because of the presence of ion steering effects at the interface between the layer and the substrate. Despite this physical limitation caused by ion steering, our results show that full bidimensional patterns can be applied to detect fingerprints and enhance the accuracy for most critical cases, in which the angular shift associated to the lattice distortion is below the critical angle for channelling.

  5. Channelized relevance vector machine as a numerical observer for cardiac perfusion defect detection task

    Science.gov (United States)

    Kalayeh, Mahdi M.; Marin, Thibault; Pretorius, P. Hendrik; Wernick, Miles N.; Yang, Yongyi; Brankov, Jovan G.

    2011-03-01

    In this paper, we present a numerical observer for image quality assessment, aiming to predict human observer accuracy in a cardiac perfusion defect detection task for single-photon emission computed tomography (SPECT). In medical imaging, image quality should be assessed by evaluating the human observer accuracy for a specific diagnostic task. This approach is known as task-based assessment. Such evaluations are important for optimizing and testing imaging devices and algorithms. Unfortunately, human observer studies with expert readers are costly and time-demanding. To address this problem, numerical observers have been developed as a surrogate for human readers to predict human diagnostic performance. The channelized Hotelling observer (CHO) with internal noise model has been found to predict human performance well in some situations, but does not always generalize well to unseen data. We have argued in the past that finding a model to predict human observers could be viewed as a machine learning problem. Following this approach, in this paper we propose a channelized relevance vector machine (CRVM) to predict human diagnostic scores in a detection task. We have previously used channelized support vector machines (CSVM) to predict human scores and have shown that this approach offers better and more robust predictions than the classical CHO method. The comparison of the proposed CRVM with our previously introduced CSVM method suggests that CRVM can achieve similar generalization accuracy, while dramatically reducing model complexity and computation time.

  6. Exploiting the Lab-on-Valve Concept for Determination of Trace Levels of Metals in Complex Matrices with Detection by ETAAS and ICPMS

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Wang, Jianhua

    approach [1,2]. Coupled to detection by ETAAS and ICPMS, and illustrated by recent exploits in the authors’ laboratory, it is shown that this methodology eliminates the problems encountered in conventional on-line column preconcentration systems and at the same time improves the overall operational......Termed the third generation of flow injection analysis, the Sequential Injection (SI)-Lab-on-Valve (LOV) concept has proven to entail specific advantages and to allow novel and unique applications. Both in term of its use in the automation and micro-miniaturization of suitable on-line sample...

  7. Automatic detection and classification of artifacts in single-channel EEG

    DEFF Research Database (Denmark)

    Olund, Thomas; Duun-Henriksen, Jonas; Kjaer, Troels W.

    2014-01-01

    Ambulatory EEG monitoring can provide medical doctors important diagnostic information, without hospitalizing the patient. These recordings are however more exposed to noise and artifacts compared to clinically recorded EEG. An automatic artifact detection and classification algorithm for single......-channel EEG is proposed to help identifying these artifacts. Features are extracted from the EEG signal and wavelet subbands. Subsequently a selection algorithm is applied in order to identify the best discriminating features. A non-linear support vector machine is used to discriminate among different...... artifact classes using the selected features. Single-channel (Fp1-F7) EEG recordings are obtained from experiments with 12 healthy subjects performing artifact inducing movements. The dataset was used to construct and validate the model. Both subject-specific and generic implementation, are investigated...

  8. Analysis of gate underlap channel double gate MOS transistor for electrical detection of bio-molecules

    Science.gov (United States)

    Ajay; Narang, Rakhi; Saxena, Manoj; Gupta, Mridula

    2015-12-01

    In this paper, an analytical model for gate drain underlap channel Double-Gate Metal-Oxide-Semiconductor Field-Effect Transistor (DG-MOSFET) for label free electrical detection of biomolecules has been proposed. The conformal mapping technique has been used to derive the expressions for surface potential, lateral electric field, energy bands (i.e. conduction and valence band) and threshold voltage (Vth). Subsequently a full drain current model to analyze the sensitivity of the biosensor has been developed. The shift in the threshold voltage and drain current (after the biomolecules interaction with the gate underlap channel region of the MOS transistor) has been used as a sensing metric. All the characteristic trends have been verified through ATLAS (SILVACO) device simulation results.

  9. Detecting CP violation in a single neutrino oscillation channel at very long baselines

    International Nuclear Information System (INIS)

    Latimer, D. C.; Escamilla, J.; Ernst, D. J.

    2007-01-01

    We propose a way of detecting CP violation in a single neutrino oscillation channel at very long baselines (on the order of several thousands of kilometers), given precise knowledge of the smallest mass-squared difference. It is shown that CP violation can be characterized by a shift in L/E of the peak oscillation in the ν e -ν μ appearance channel, both in vacuum and in matter. In fact, matter effects enhance the shift at a fixed energy. We consider the case in which sub-GeV neutrinos are measured with varying baseline and also the case of a fixed baseline. For the varied baseline, accurate knowledge of the absolute neutrino flux would not be necessary; however, neutrinos must be distinguishable from antineutrinos. For the fixed baseline, it is shown that CP violation can be distinguished if the mixing angle θ 13 were known

  10. A burst-mode photon counting receiver with automatic channel estimation and bit rate detection

    Science.gov (United States)

    Rao, Hemonth G.; DeVoe, Catherine E.; Fletcher, Andrew S.; Gaschits, Igor D.; Hakimi, Farhad; Hamilton, Scott A.; Hardy, Nicholas D.; Ingwersen, John G.; Kaminsky, Richard D.; Moores, John D.; Scheinbart, Marvin S.; Yarnall, Timothy M.

    2016-04-01

    We demonstrate a multi-rate burst-mode photon-counting receiver for undersea communication at data rates up to 10.416 Mb/s over a 30-foot water channel. To the best of our knowledge, this is the first demonstration of burst-mode photon-counting communication. With added attenuation, the maximum link loss is 97.1 dB at λ=517 nm. In clear ocean water, this equates to link distances up to 148 meters. For λ=470 nm, the achievable link distance in clear ocean water is 450 meters. The receiver incorporates soft-decision forward error correction (FEC) based on a product code of an inner LDPC code and an outer BCH code. The FEC supports multiple code rates to achieve error-free performance. We have selected a burst-mode receiver architecture to provide robust performance with respect to unpredictable channel obstructions. The receiver is capable of on-the-fly data rate detection and adapts to changing levels of signal and background light. The receiver updates its phase alignment and channel estimates every 1.6 ms, allowing for rapid changes in water quality as well as motion between transmitter and receiver. We demonstrate on-the-fly rate detection, channel BER within 0.2 dB of theory across all data rates, and error-free performance within 1.82 dB of soft-decision capacity across all tested code rates. All signal processing is done in FPGAs and runs continuously in real time.

  11. An expert protocol for immunofluorescent detection of calcium channels in tsA-201 cells.

    Science.gov (United States)

    Koch, Peter; Herzig, Stefan; Matthes, Jan

    Pore-forming subunits of voltage gated calcium channels (VGCC) are large membrane proteins (260kDa) containing 24 transmembrane domains. Despite transfection with viral promoter driven vectors, biochemical analysis of VGCC is often hampered by rather low expression levels in heterologous systems rendering VGCC challenging targets. Especially in immunofluorescent detection, calcium channels are demanding proteins. We provide an expert step-by-step protocol with adapted conditions for handling procedures (tsA-201 cell culture, transient transfection, incubation time and temperature at 28°C or 37°C and immunostaining) to address the L-type calcium-channel pore Ca v 1.2 in an immunofluorescent approach. We performed immunocytochemical analysis of Ca v 1.2 expression at single-cell level in combination with detection of different markers for cellular organelles. We show confluency levels and shapes of tsA-201 cells at different time points during an experiment. Our experiments reveal sufficient levels of Ca v 1.2 protein and a correct Ca v 1.2 expression pattern in polygonal shaped cells already 12h after transfection. A sequence of elaborated protocol modifications allows subcellular localization analysis of Ca v 1.2 in an immunocytochemical approach. We provide a protocol that may be used to achieve insights into physiological and pathophysiological processes involving voltage gated calcium channels. Our protocol may be used for expression analysis of other challenging proteins and efficient overexpression may be exploited in related biochemical techniques requiring immunolabels. Copyright © 2016 Elsevier Inc. All rights reserved.

  12. Detection of alpha-fetoprotein in magnetic immunoassay of thin channels using biofunctional nanoparticles

    Science.gov (United States)

    Tsai, H. Y.; Gao, B. Z.; Yang, S. F.; Li, C. S.; Fuh, C. Bor

    2014-01-01

    This paper presents the use of fluorescent biofunctional nanoparticles (10-30 nm) to detect alpha-fetoprotein (AFP) in a thin-channel magnetic immunoassay. We used an AFP model biomarker and s-shaped deposition zones to test the proposed detection method. The results show that the detection using fluorescent biofunctional nanoparticle has a higher throughput than that of functional microparticle used in previous experiments on affinity reactions. The proposed method takes about 3 min (versus 150 min of previous method) to detect 100 samples. The proposed method is useful for screening biomarkers in clinical applications, and can reduce the run time for sandwich immunoassays to less than 20 min. The detection limits (0.06 pg/ml) and linear ranges (0.068 pg/ml-0.68 ng/ml) of AFP using fluorescent biofunctional nanoparticles are the same as those of using functional microparticles within experimental errors. This detection limit is substantially lower and the linear range is considerably wider than those of enzyme-linked immunosorbent assay (ELISA) and other methods in sandwich immunoassay methods. The differences between this method and an ELISA in AFP measurements of serum samples were less than 12 %. The proposed method provides simple, fast, and sensitive detection with a high throughput for biomarkers.

  13. A 16-Channel Nonparametric Spike Detection ASIC Based on EC-PC Decomposition.

    Science.gov (United States)

    Wu, Tong; Xu, Jian; Lian, Yong; Khalili, Azam; Rastegarnia, Amir; Guan, Cuntai; Yang, Zhi

    2016-02-01

    In extracellular neural recording experiments, detecting neural spikes is an important step for reliable information decoding. A successful implementation in integrated circuits can achieve substantial data volume reduction, potentially enabling a wireless operation and closed-loop system. In this paper, we report a 16-channel neural spike detection chip based on a customized spike detection method named as exponential component-polynomial component (EC-PC) algorithm. This algorithm features a reliable prediction of spikes by applying a probability threshold. The chip takes raw data as input and outputs three data streams simultaneously: field potentials, band-pass filtered neural data, and spiking probability maps. The algorithm parameters are on-chip configured automatically based on input data, which avoids manual parameter tuning. The chip has been tested with both in vivo experiments for functional verification and bench-top experiments for quantitative performance assessment. The system has a total power consumption of 1.36 mW and occupies an area of 6.71 mm (2) for 16 channels. When tested on synthesized datasets with spikes and noise segments extracted from in vivo preparations and scaled according to required precisions, the chip outperforms other detectors. A credit card sized prototype board is developed to provide power and data management through a USB port.

  14. Detection of DNA and poly-l-lysine using CVD graphene-channel FET biosensors

    International Nuclear Information System (INIS)

    Kakatkar, Aniket; Craighead, H G; Abhilash, T S; Alba, R De; Parpia, J M

    2015-01-01

    A graphene channel field-effect biosensor is demonstrated for detecting the binding of double-stranded DNA and poly-l-lysine. Sensors consist of chemical vapor deposition graphene transferred using a clean, etchant-free transfer method. The presence of DNA and poly-l-lysine are detected by the conductance change of the graphene transistor. A readily measured shift in the Dirac voltage (the voltage at which the graphene’s resistance peaks) is observed after the graphene channel is exposed to solutions containing DNA or poly-l-lysine. The ‘Dirac voltage shift’ is attributed to the binding/unbinding of charged molecules on the graphene surface. The polarity of the response changes to positive direction with poly-l-lysine and negative direction with DNA. This response results in detection limits of 8 pM for 48.5 kbp DNA and 11 pM for poly-l-lysine. The biosensors are easy to fabricate, reusable and are promising as sensors of a wide variety of charged biomolecules. (paper)

  15. Detections of Planets in Binaries Through the Channel of Chang–Refsdal Gravitational Lensing Events

    Energy Technology Data Exchange (ETDEWEB)

    Han, Cheongho [Department of Physics, Chungbuk National University, Cheongju 361-763 (Korea, Republic of); Shin, In-Gu; Jung, Youn Kil [Harvard-Smithsonian Center for Astrophysics, 60 Garden St., Cambridge, MA 02138 (United States)

    2017-02-01

    Chang–Refsdal (C–R) lensing, which refers to the gravitational lensing of a point mass perturbed by a constant external shear, provides a good approximation in describing lensing behaviors of either a very wide or a very close binary lens. C–R lensing events, which are identified by short-term anomalies near the peak of high-magnification lensing light curves, are routinely detected from lensing surveys, but not much attention is paid to them. In this paper, we point out that C–R lensing events provide an important channel to detect planets in binaries, both in close and wide binary systems. Detecting planets through the C–R lensing event channel is possible because the planet-induced perturbation occurs in the same region of the C–R lensing-induced anomaly and thus the existence of the planet can be identified by the additional deviation in the central perturbation. By presenting the analysis of the actually observed C–R lensing event OGLE-2015-BLG-1319, we demonstrate that dense and high-precision coverage of a C–R lensing-induced perturbation can provide a strong constraint on the existence of a planet in a wide range of planet parameters. The sample of an increased number of microlensing planets in binary systems will provide important observational constraints in giving shape to the details of planet formation, which have been restricted to the case of single stars to date.

  16. Flexible Method for the Automated Offline-Detection of Artifacts in Multi-Channel Electroencephalogram Recordings

    DEFF Research Database (Denmark)

    Waser, Markus; Garn, Heinrich; Benke, Thomas

    2017-01-01

    . However, these preprocessing steps do not allow for complete artifact correction. We propose a method for the automated offline-detection of remaining artifacts after preprocessing in multi-channel EEG recordings. In contrast to existing methods it requires neither adaptive parameters varying between...... recordings nor a topography template. It is suited for short EEG segments and is flexible with regard to target applications. The algorithm was developed and tested on 60 clinical EEG samples of 20 seconds each that were recorded both in resting state and during cognitive activation to gain a realistic...

  17. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  18. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  19. A Fractional Lower Order Statistics-Based MIMO Detection Method in Impulse Noise for Power Line Channel

    Directory of Open Access Journals (Sweden)

    CHEN, Z.

    2014-11-01

    Full Text Available Impulse noise in power line communication (PLC channel seriously degrades the performance of Multiple-Input Multiple-Output (MIMO system. To remedy this problem, a MIMO detection method based on fractional lower order statistics (FLOS for PLC channel with impulse noise is proposed in this paper. The alpha stable distribution is used to model impulse noise, and FLOS is applied to construct the criteria of MIMO detection. Then the optimal detection solution is obtained by recursive least squares algorithm. Finally, the transmitted signals in PLC MIMO system are restored with the obtained detection matrix. The proposed method does not require channel estimation and has low computational complexity. The simulation results show that the proposed method has a better PLC MIMO detection performance than the existing ones under impulsive noise environment.

  20. Eddy current detection of spacers in the fuel channels of CANDU nuclear reactors

    International Nuclear Information System (INIS)

    Krause, T.W.; Schankula, J.; Sullivan, S.P.

    2002-01-01

    Garter Spring (GS) spacers in the fuel channels of CANDU nuclear reactors maintain separation between the hot pressure tube and surrounding moderator cooled calandria tube. Eddy current detection of the four GSs provides assurance that spacers are at or close to design positions and are performing their intended function of maintaining a non-zero gap between pressure tube and calandria tube. Pressure tube constrictions, resulting from relatively less diametral creep at end-of-fuel bundle locations, also produce large eddy current signals. Large constrictions, present in higher service pressure tubes, can produce signals that are 10 times larger than GS signals, reducing GS detectability to 30% in standard GS-detect probes. The introduction of field-focussing elements into the design of the standard GS detection eddy current probe has been used to recover the detectability of GS spacers by increasing the signal amplitude obtained from GSs relative to that from constrictions by a factor of 10. The work presented here compares laboratory, modelling and in-reactor measurements of GS and constriction signals obtained from the standard probe with that obtained from field-focussed eddy current probe designs. (author)

  1. Automatic seizure detection based on the combination of newborn multi-channel EEG and HRV information

    Science.gov (United States)

    Mesbah, Mostefa; Balakrishnan, Malarvili; Colditz, Paul B.; Boashash, Boualem

    2012-12-01

    This article proposes a new method for newborn seizure detection that uses information extracted from both multi-channel electroencephalogram (EEG) and a single channel electrocardiogram (ECG). The aim of the study is to assess whether additional information extracted from ECG can improve the performance of seizure detectors based solely on EEG. Two different approaches were used to combine this extracted information. The first approach, known as feature fusion, involves combining features extracted from EEG and heart rate variability (HRV) into a single feature vector prior to feeding it to a classifier. The second approach, called classifier or decision fusion, is achieved by combining the independent decisions of the EEG and the HRV-based classifiers. Tested on recordings obtained from eight newborns with identified EEG seizures, the proposed neonatal seizure detection algorithms achieved 95.20% sensitivity and 88.60% specificity for the feature fusion case and 95.20% sensitivity and 94.30% specificity for the classifier fusion case. These results are considerably better than those involving classifiers using EEG only (80.90%, 86.50%) or HRV only (85.70%, 84.60%).

  2. Fabrication of high performance microlenses for an integrated capillary channel electrochromatograph with fluorescence detection

    International Nuclear Information System (INIS)

    Wendt, J. R.; Warren, M. E.; Sweatt, W. C.; Bailey, C. G.; Matzke, C. M.; Arnold, D. W.; Allerman, A. A.; Carter, T. R.; Asbill, R. E.; Samora, S.

    1999-01-01

    We describe the microfabrication of an extremely compact optical system as a key element in an integrated capillary channel electrochromatograph with fluorescence detection. The optical system consists of a vertical cavity surface-emitting laser (VCSEL), two high performance microlenses, and a commercial photodetector. The microlenses are multilevel diffractive optics patterned by electron beam lithography and etched by reactive ion etching in fused silica. The design uses substrate-mode propagation within the fused silica substrate. Two generations of optical subsystems are described. The first generation design has a 6 mm optical length and is integrated directly onto the capillary channel-containing substrate. The second generation design separates the optical system onto its own substrate module and the optical path length is further compressed to 3.5 mm. The first generation design has been tested using direct fluorescence detection with a 750 nm VCSEL pumping a 10 -4 M solution of CY-7 dye. The observed signal-to-noise ratio of better than 100:1 demonstrates that the background signal from scattered pump light is low despite the compact size of the optical system and is adequate for system sensitivity requirements. (c) 1999 American Vacuum Society

  3. Noninvasive radioisotopic technique for detection of platelet deposition in mitral valve prostheses and quantitation of visceral microembolism in dogs

    International Nuclear Information System (INIS)

    Dewanjee, M.K.; Fuster, V.; Rao, S.A.; Forshaw, P.L.; Kaye, M.P.

    1983-01-01

    A noninvasive technique has been developed in the dog model for imaging, with a gamma camera, the platelet deposition on Bjoerk-Shiley mitral valve prostheses early postoperatively. At 25 hours after implantation of the prosthesis and 24 hours after intravenous administration of 400 to 500 microCi of platelets labeled with indium-111, the platelet deposition in the sewing ring and perivalvular cardiac tissue can be clearly delineated in a scintiphotograph. An in vitro technique was also developed for quantitation of visceral microemboli in brain, lungs, kidneys, and other tissues. Biodistribution of the labeled platelets was quantitated, and the tissue/blood radioactivity ratio was determined in 22 dogs in four groups: unoperated normal dogs, sham-operated dogs, prosthesis-implanted dogs, and prosthesis-implanted dogs treated with dipyridamole before and aspirin and dipyridamole immediately after operation. Fifteen to 20% of total platelets were consumed as a consequence of the surgical procedure. On quantitation, we found that platelet deposition on the components of the prostheses was significantly reduced in prosthesis-implanted animals treated with dipyridamole and aspirin when compared with prosthesis-implanted, untreated dogs. All prosthesis-implanted animals considered together had a twofold to fourfold increase in tissue/blood radioactivity ratio in comparison with unoperated and sham-operated animals, an indication that the viscera work as filters and trap platelet microemboli that are presumably produced in the region of the mitral valve prostheses. In the dog model, indium-111-labeled platelets thus provide a sensitive marker for noninvasive imaging of platelet deposition on mechanical mitral valve prostheses, in vitro evaluation of platelet microembolism in viscera, in vitro quantitation of surgical consumption of platelets, and evaluation of platelet-inhibitor drugs

  4. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    Energy Technology Data Exchange (ETDEWEB)

    Mukherjee, S; Ghosh, J K [Bhabha Atomic Research Centre, Bombay (India). Radiometallurgy Div.; Patel, R J [Bhabha Atomic Research Centre, Mumbai (India). Refuelling Technology Division

    1994-12-31

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs.

  5. On line monitoring of temperatures of coolant channels by thermal imaging in a laboratory set-up fabricated for the detection of leakage of coolants

    International Nuclear Information System (INIS)

    Mukherjee, S.; Ghosh, J.K.; Patel, R.J.

    1994-01-01

    Leakage from coolant channels in Pressurised Heavy Water Reactors (PHWR) increases the temperatures of the faulty channels. Measurement of temperatures of the coolant channels is, therefore, one way to detect the leaking channel. Thermal imaging technique offers a unique means for this detection providing a fast, non-contact, on-line measurement. An experiment was carried out for the detection of leakage of coolants through the seal plugs of the coolant channels in PHWR using an experimental setup under the simulated conditions of temperature and pressure of the coolant channels inside the reactor and using an infrared imaging system. The experimental details and the observations have been presented. 7 figs

  6. Extraction and preconcentration of trace levels of cobalt using functionalized magnetic nanoparticles in a sequential injection lab-on-valve system with detection by electrothermal atomic absorption spectrometry

    International Nuclear Information System (INIS)

    Wang Yang; Luo Xiaoyu; Tang Jie; Hu Xiaoya; Xu Qin; Yang Chun

    2012-01-01

    Graphical abstract: An approach to performing extraction and preconcentration employing functionalized magnetic particles for the determination of cobalt in the sequential injection lab-on-valve system using detection by electrothermal atomic absorption spectrometry. Highlights: ► New SPE method for cobalt separation/preconcentration was reported. ► Functionalized magnetic nanoparticles were used as adsorbent. ► Extraction, elution, and detection procedures were performed in the LOV system. ► This automatic extraction technique provided a good platform for metal analysis. - Abstract: A new approach to performing extraction and preconcentration employing functionalized magnetic nanoparticles for the determination of trace metals is presented. Alumina-coated iron oxide nanoparticles were synthesized and used as the solid support. The nanoparticles were functionalized with sodium dodecyl sulfate and used as adsorbents for solid phase extraction of the analyte. Extraction, elution, and detection procedures were performed sequentially in the sequential injection lab-on-valve (SI-LOV) system followed by electrothermal atomic absorption spectrometry (ETAAS). Mixtures of hydrophobic analytes were successfully extracted from solution using the synthesized magnetic adsorbents. The potential use of the established scheme was demonstrated by taking cobalt as a model analyte. Under the optimal conditions, the calibration curve showed an excellent linearity in the concentration range of 0.01–5 μg L −1 , and the relative standard deviation was 2.8% at the 0.5 μg L −1 level (n = 11). The limit of detection was 6 ng L −1 with a sampling frequency of 18 h −1 . The present method has been successfully applied to cobalt determination in water samples and two certified reference materials.

  7. Detection of TRPV4 channel current-like activity in Fawn Hooded hypertensive (FHH rat cerebral arterial muscle cells.

    Directory of Open Access Journals (Sweden)

    Debebe Gebremedhin

    Full Text Available The transient receptor potential vallinoid type 4 (TRPV4 is a calcium entry channel known to modulate vascular function by mediating endothelium-dependent vasodilation. The present study investigated if isolated cerebral arterial myocytes of the Fawn Hooded hypertensive (FHH rat, known to display exaggerated KCa channel current activity and impaired myogenic tone, express TRPV4 channels at the transcript and protein level and exhibit TRPV4-like single-channel cationic current activity. Reverse transcription polymerase chain reaction (RT-PCR, Western blot, and immunostaining analysis detected the expression of mRNA transcript and translated protein of TRPV4 channel in FHH rat cerebral arterial myocytes. Patch clamp recording of single-channel current activity identified the presence of a single-channel cationic current with unitary conductance of ~85 pS and ~96 pS at hyperpolarizing and depolarizing potentials, respectively, that was inhibited by the TRPV4 channel antagonist RN 1734 or HC 067074 and activated by the potent TRPV4 channel agonist GSK1016790A. Application of negative pressure via the interior of the patch pipette increased the NPo of the TRPV4-like single-channel cationic current recorded in cell-attached patches at a patch potential of 60 mV that was inhibited by prior application of the TRPV4 channel antagonist RN 1734 or HC 067047. Treatment with the TRPV4 channel agonist GSK1016790A caused concentration-dependent increase in the NPo of KCa single-channel current recorded in cell-attached patches of cerebral arterial myocytes at a patch potential of 40 mV, which was not influenced by pretreatment with the voltage-gated L-type Ca2+ channel blocker nifedipine or the T-type Ca2+ channel blocker Ni2+. These findings demonstrate that FHH rat cerebral arterial myocytes express mRNA transcript and translated protein for TRPV4 channel and display TRPV4-like single-channel cationic current activity that was stretch-sensitive and

  8. Growth and Filling Regularities of Filamentary Channels in Non-Metallic Inorganic Coatings Under Anodic Oxidation of Valve Metals. Mathematical Modeling

    Science.gov (United States)

    Mamaev, A. I.; Mamaeva, V. A.; Kolenchin, N. F.; Chubenko, A. K.; Kovalskaya, Ya. B.; Dolgova, Yu. N.; Beletskaya, E. Yu.

    2015-12-01

    Theoretical models are developed for growth and filling processes in filamentary channels of nanostructured non-metallic coatings produced by anodizing and microplasma oxidation. Graphical concentration distributions are obtained for channel-reacting anions, cations, and sparingly soluble reaction products depending on the time of electric current transmission and the length of the filamentary channel. Graphical distributions of the front moving velocity for the sparingly soluble compound are presented. The resulting model representation increases the understanding of the anodic process nature and can be used for a description and prediction of porous anodic film growth and filling. It is shown that the character of the filamentary channel growth and filling causes a variety of processes determining the textured metal - nonmetallic inorganic coating phase boundary formation.

  9. An electronic channel switching-based aptasensor for ultrasensitive protein detection

    Energy Technology Data Exchange (ETDEWEB)

    Li Hongbo; Wang Cui [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Wu Zaisheng, E-mail: wuzaisheng@163.com [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Lu Limin; Qiu Liping; Zhou Hui; Shen Guoli [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China); Yu Ruqin, E-mail: rqyu@hnu.edu.cn [State Key Laboratory for Chemo/Biosensing and Chemometrics, College of Chemistry and Chemical Engineering, Hunan University, Changsha 410082 (China)

    2013-01-03

    Highlights: Black-Right-Pointing-Pointer Target IgE is successfully designed to serve as a barrier to separate enzyme from its substrate. Black-Right-Pointing-Pointer This sensing platform of electronic channel switching-based aptasensor can be simply manipulated. Black-Right-Pointing-Pointer The stable hairpin structure of anti-IgE aptamer is utilized to detect target IgE. Black-Right-Pointing-Pointer The sensor is ultrasensitive sensitivity, excellent selectivity and small volume of sample. Black-Right-Pointing-Pointer It is a powerful platform to be further expanded to detect more kinds of proteins and even cells. - Abstract: Due to the ubiquity and essential of the proteins in all living organisms, the identification and quantification of disease-specific proteins are particularly important. Because the conformational change of aptamer upon its target or probe/target/probe sandwich often is the primary prerequisite for the design of an electrochemical aptameric assay system, it is extremely difficult to construct the electrochemical aptasensor for protein assay because the corresponding aptamers cannot often meet the requirement. To circumvent the obstacles mentioned, an electronic channel switching-based (ECS) aptasensor for ultrasensitive protein detection is developed. The essential achievement made is that an innovative sensing concept is proposed: the hairpin structure of aptamer is designed to pull electroactive species toward electrode surface and makes the surface-immobilized IgE serve as a barrier that separates enzyme from its substrate. It seemingly ensures that the ECS aptasensor exhibits most excellent assay features, such as, a detection limit of 4.44 Multiplication-Sign 10{sup -6} {mu}g mL{sup -1} (22.7 fM, 220 zmol in 10-{mu}L sample) (demonstrating a 5 orders of magnitude improvement in detection sensitivity compared with classical electronic aptasensors) and dynamic response range from 4.44 Multiplication-Sign 10{sup -6} to 4.44 Multiplication

  10. Photoionisation detection of single 87Rb-atoms using channel electron multipliers

    International Nuclear Information System (INIS)

    Henkel, Florian Alexander

    2011-01-01

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p ion =0.991 within an ionisation time of t ion =386 ns is achieved for a single 87 Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of η atom =0.991 within a detection time of t det =415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral 87 Rb-atoms via photoionisation detection with an estimated detection efficiency η=0.982 and a detection time of t tot = 802 ns. Although initially developed for single 87 Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any atomic or molecular species. As efficient

  11. Photoionisation detection of single {sup 87}Rb-atoms using channel electron multipliers

    Energy Technology Data Exchange (ETDEWEB)

    Henkel, Florian Alexander

    2011-09-02

    Fast and efficient detection of single atoms is a universal requirement concerning modern experiments in atom physics, quantum optics, and precision spectroscopy. In particular for future quantum information and quantum communication technologies, the efficient readout of qubit states encoded in single atoms or ions is an elementary prerequisite. The rapid development in the field of quantum optics and atom optics in the recent years has enabled to prepare individual atoms as quantum memories or arrays of single atoms as qubit registers. With such systems, the implementation of quantum computation or quantum communication protocols seems feasible. This thesis describes a novel detection scheme which enables fast and efficient state analysis of single neutral atoms. The detection scheme is based on photoionisation and consists of two parts: the hyperfine-state selective photoionisation of single atoms and the registration of the generated photoion-electron pairs via two channel electron multipliers (CEMs). In this work, both parts were investigated in two separate experiments. For the first step, a photoionisation probability of p{sub ion}=0.991 within an ionisation time of t{sub ion}=386 ns is achieved for a single {sup 87}Rb-atom in an optical dipole trap. For the second part, a compact detection system for the ionisation fragments was developed consisting of two opposing CEM detectors. Measurements show that single neutral atoms can be detected via their ionisation fragments with a detection efficiency of {eta}{sub atom}=0.991 within a detection time of t{sub det}=415.5 ns. In a future combined setup, this will allow the state-selective readout of optically trapped, single neutral {sup 87}Rb-atoms via photoionisation detection with an estimated detection efficiency {eta}=0.982 and a detection time of t{sub tot} = 802 ns. Although initially developed for single {sup 87}Rb-atoms, the concept of photoionisation detection is in principle generally applicable to any

  12. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  13. Multi-channel up-conversion infrared spectrometer and method of detecting a spectral distribution of light

    DEFF Research Database (Denmark)

    2015-01-01

    A multi-channel infrared spectrometer for detecting an infrared spectrum of light received from an object. The spectrometer comprises a wavelength converter system comprising a nonlinear material and having an input side and an output side. The wavelength converter system comprises at least a first...... on the first side into light in a second output wavelength range output on the second side. The spectrometer further comprises a demultiplexer configured for demultiplexing light in the first up-conversion channel and light in the second up-conversion channel. The demultiplexer is located on the first side...

  14. Chemical Selectivity and Sensitivity of a 16-Channel Electronic Nose for Trace Vapour Detection

    Directory of Open Access Journals (Sweden)

    Drago Strle

    2017-12-01

    Full Text Available Good chemical selectivity of sensors for detecting vapour traces of targeted molecules is vital to reliable detection systems for explosives and other harmful materials. We present the design, construction and measurements of the electronic response of a 16 channel electronic nose based on 16 differential microcapacitors, which were surface-functionalized by different silanes. The e-nose detects less than 1 molecule of TNT out of 10+12 N2 molecules in a carrier gas in 1 s. Differently silanized sensors give different responses to different molecules. Electronic responses are presented for TNT, RDX, DNT, H2S, HCN, FeS, NH3, propane, methanol, acetone, ethanol, methane, toluene and water. We consider the number density of these molecules and find that silane surfaces show extreme affinity for attracting molecules of TNT, DNT and RDX. The probability to bind these molecules and form a surface-adsorbate is typically 10+7 times larger than the probability to bind water molecules, for example. We present a matrix of responses of differently functionalized microcapacitors and we propose that chemical selectivity of multichannel e-nose could be enhanced by using artificial intelligence deep learning methods.

  15. EEG channels reduction using PCA to increase XGBoost's accuracy for stroke detection

    Science.gov (United States)

    Fitriah, N.; Wijaya, S. K.; Fanany, M. I.; Badri, C.; Rezal, M.

    2017-07-01

    In Indonesia, based on the result of Basic Health Research 2013, the number of stroke patients had increased from 8.3 ‰ (2007) to 12.1 ‰ (2013). These days, some researchers are using electroencephalography (EEG) result as another option to detect the stroke disease besides CT Scan image as the gold standard. A previous study on the data of stroke and healthy patients in National Brain Center Hospital (RS PON) used Brain Symmetry Index (BSI), Delta-Alpha Ratio (DAR), and Delta-Theta-Alpha-Beta Ratio (DTABR) as the features for classification by an Extreme Learning Machine (ELM). The study got 85% accuracy with sensitivity above 86 % for acute ischemic stroke detection. Using EEG data means dealing with many data dimensions, and it can reduce the accuracy of classifier (the curse of dimensionality). Principal Component Analysis (PCA) could reduce dimensionality and computation cost without decreasing classification accuracy. XGBoost, as the scalable tree boosting classifier, can solve real-world scale problems (Higgs Boson and Allstate dataset) with using a minimal amount of resources. This paper reuses the same data from RS PON and features from previous research, preprocessed with PCA and classified with XGBoost, to increase the accuracy with fewer electrodes. The specific fewer electrodes improved the accuracy of stroke detection. Our future work will examine the other algorithm besides PCA to get higher accuracy with less number of channels.

  16. Leveraging KVM Events to Detect Cache-Based Side Channel Attacks in a Virtualization Environment

    Directory of Open Access Journals (Sweden)

    Ady Wahyudi Paundu

    2018-01-01

    Full Text Available Cache-based side channel attack (CSCa techniques in virtualization systems are becoming more advanced, while defense methods against them are still perceived as nonpractical. The most recent CSCa variant called Flush + Flush has showed that the current detection methods can be easily bypassed. Within this work, we introduce a novel monitoring approach to detect CSCa operations inside a virtualization environment. We utilize the Kernel Virtual Machine (KVM event data in the kernel and process this data using a machine learning technique to identify any CSCa operation in the guest Virtual Machine (VM. We evaluate our approach using Receiver Operating Characteristic (ROC diagram of multiple attack and benign operation scenarios. Our method successfully separate the CSCa datasets from the non-CSCa datasets, on both trained and nontrained data scenarios. The successful classification also include the Flush + Flush attack scenario. We are also able to explain the classification results by extracting the set of most important features that separate both classes using their Fisher scores and show that our monitoring approach can work to detect CSCa in general. Finally, we evaluate the overhead impact of our CSCa monitoring method and show that it has a negligible computation overhead on the host and the guest VM.

  17. Cooperation schemes for rate enhancement in detect-and-forward relay channels

    KAUST Repository

    Benjillali, Mustapha

    2010-05-01

    To improve the spectral efficiency of "Detect-and-Forward" (DetF) half-duplex relaying in fading channels, we propose a cooperation scheme where the relay uses a modulation whose order is higher than the one at the source. In a new common framework, we show that the proposed scheme offers considerable gains - in terms of achievable information rates - compared to the conventional DetF relaying schemes for both orthogonal and non-orthogonal source/relay cooperation. This allows us to propose an adaptive cooperation scheme based on the maximization of the information rate at the destination which needs to observe only the average signal-to-noise ratios of direct and relaying links. ©2010 IEEE.

  18. Drowsiness detection for single channel EEG by DWT best m-term approximation

    Directory of Open Access Journals (Sweden)

    Tiago da Silveira

    Full Text Available Introduction In this paper we propose a promising new technique for drowsiness detection. It consists of applying the best m-term approximation on a single-channel electroencephalography (EEG signal preprocessed through a discrete wavelet transform. Methods In order to classify EEG epochs as awake or drowsy states, the most significant m terms from the wavelet expansion of an EEG signal are selected according to the magnitude of their coefficients related to the alpha and beta rhythms. Results By using a simple thresholding strategy it provides hit rates comparable to those using more complex techniques. It was tested on a set of 6 hours and 50 minutes EEG drowsiness signals from PhysioNet Sleep Database yielding an overall sensitivity (TPR of 84.98% and 98.65% of precision (PPV. Conclusion The method has proved itself efficient at separating data from different brain rhythms, thus alleviating the requirement for complex post-processing classification algorithms.

  19. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  20. Multi-channel Waveform Sampling ASIC for radiation detection and measurement

    International Nuclear Information System (INIS)

    Shimazoe, K.; Takahashi, H.; Yeom, J.Y.; Furumiya, T.; Ohi, J.

    2013-01-01

    We have designed and fabricated a 16-channel Waveform Sampling ASIC for radiation detection and measurement. Waveform sampling is very important for the pulse shape analysis and discrimination, which is often used in radiation detection to discriminate different radiations such as alpha, beta and gamma rays. One channel of the fabricated ASIC consists of a charge-sensitive preamplifier, a VGA (Variable Gain Amplifier), an ADC (Analog to Digital Converter) and digital circuits. The preamplifier converts the current signal to the voltage signal, and the VGA amplifies the signal to appropriate level for the ADC. The ADC was designed to digitize the waveform with a frequency of 100 MHz and a resolution of 6bits. Digital circuits consist of a free-running ADC and a multiplexer which were designed to convert a digitized 100 MHz/6bit signal to a 200 MHz/3bit one, which is effective for the reduction of the number and for the achievement of the high integration in one chip. This chip was designed and fabricated with 0.35 μm CMOS technology by ROHM and the size of the ASIC is 4.9 mm by 4.9 mm. The design concept and some experimental results are shown in this paper. -- Highlights: ► Waveform sampling (WS) ASIC is newly developed for pulse shape discrimination. ► WS ASIC can be used for radiation measurement and discrimination. ► WS ASIC is fabricated by submicron CMOS technology for 5 mm × 5 mm area. ► WS ASIC achieves high integration and can be used in very limited space

  1. Multi-feature classifiers for burst detection in single EEG channels from preterm infants

    Science.gov (United States)

    Navarro, X.; Porée, F.; Kuchenbuch, M.; Chavez, M.; Beuchée, Alain; Carrault, G.

    2017-08-01

    Objective. The study of electroencephalographic (EEG) bursts in preterm infants provides valuable information about maturation or prognostication after perinatal asphyxia. Over the last two decades, a number of works proposed algorithms to automatically detect EEG bursts in preterm infants, but they were designed for populations under 35 weeks of post menstrual age (PMA). However, as the brain activity evolves rapidly during postnatal life, these solutions might be under-performing with increasing PMA. In this work we focused on preterm infants reaching term ages (PMA  ⩾36 weeks) using multi-feature classification on a single EEG channel. Approach. Five EEG burst detectors relying on different machine learning approaches were compared: logistic regression (LR), linear discriminant analysis (LDA), k-nearest neighbors (kNN), support vector machines (SVM) and thresholding (Th). Classifiers were trained by visually labeled EEG recordings from 14 very preterm infants (born after 28 weeks of gestation) with 36-41 weeks PMA. Main results. The most performing classifiers reached about 95% accuracy (kNN, SVM and LR) whereas Th obtained 84%. Compared to human-automatic agreements, LR provided the highest scores (Cohen’s kappa  =  0.71) using only three EEG features. Applying this classifier in an unlabeled database of 21 infants  ⩾36 weeks PMA, we found that long EEG bursts and short inter-burst periods are characteristic of infants with the highest PMA and weights. Significance. In view of these results, LR-based burst detection could be a suitable tool to study maturation in monitoring or portable devices using a single EEG channel.

  2. An iterative detection method of MIMO over spatial correlated frequency selective channel: using list sphere decoding for simplification

    Science.gov (United States)

    Shi, Zhiping; Yan, Bing

    2010-08-01

    In multiple-input multiple-output(MIMO) wireless systems, combining good channel codes(e.g., Non-binary Repeat Accumulate codes) with adaptive turbo equalization is a good option to get better performance and lower complexity under Spatial Correlated Frequency Selective(SCFS) Channel. The key of this method is after joint antennas MMSE detection (JAD/MMSE) based on interruption cancelling using soft information, considering the detection result as an output of a Gaussian equivalent flat fading channel, and performing maximum likelihood detection(ML) to get more correct estimated result. But the using of ML brings great complexity increase, which is not allowed. In this paper, a low complexity method called list sphere decoding is introduced and applied to replace the ML in order to simplify the adaptive iterative turbo equalization system.

  3. Performance evaluation of an automated single-channel sleep–wake detection algorithm

    Directory of Open Access Journals (Sweden)

    Kaplan RF

    2014-10-01

    Full Text Available Richard F Kaplan,1 Ying Wang,1 Kenneth A Loparo,1,2 Monica R Kelly,3 Richard R Bootzin3 1General Sleep Corporation, Euclid, OH, USA; 2Department of Electrical Engineering and Computer Science, Case Western Reserve University, Cleveland, OH, USA; 3Department of Psychology, University of Arizona, Tucson, AZ, USA Background: A need exists, from both a clinical and a research standpoint, for objective sleep measurement systems that are both easy to use and can accurately assess sleep and wake. This study evaluates the output of an automated sleep–wake detection algorithm (Z-ALG used in the Zmachine (a portable, single-channel, electroencephalographic [EEG] acquisition and analysis system against laboratory polysomnography (PSG using a consensus of expert visual scorers. Methods: Overnight laboratory PSG studies from 99 subjects (52 females/47 males, 18–60 years, median age 32.7 years, including both normal sleepers and those with a variety of sleep disorders, were assessed. PSG data obtained from the differential mastoids (A1–A2 were assessed by Z-ALG, which determines sleep versus wake every 30 seconds using low-frequency, intermediate-frequency, and high-frequency and time domain EEG features. PSG data were independently scored by two to four certified PSG technologists, using standard Rechtschaffen and Kales guidelines, and these score files were combined on an epoch-by-epoch basis, using a majority voting rule, to generate a single score file per subject to compare against the Z-ALG output. Both epoch-by-epoch and standard sleep indices (eg, total sleep time, sleep efficiency, latency to persistent sleep, and wake after sleep onset were compared between the Z-ALG output and the technologist consensus score files. Results: Overall, the sensitivity and specificity for detecting sleep using the Z-ALG as compared to the technologist consensus are 95.5% and 92.5%, respectively, across all subjects, and the positive predictive value and the

  4. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  5. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  6. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  7. Multi-channel non-invasive fetal electrocardiography detection using wavelet decomposition

    Science.gov (United States)

    Almeida, Javier; Ruano, Josué; Corredor, Germán.; Romo-Bucheli, David; Navarro-Vargas, José Ricardo; Romero, Eduardo

    2017-11-01

    Non-invasive fetal electrocardiography (fECG) has attracted the medical community because of the importance of fetal monitoring. However, its implementation in clinical practice is challenging: the fetal signal has a low Signal- to-Noise-Ratio and several signal sources are present in the maternal abdominal electrocardiography (AECG). This paper presents a novel method to detect the fetal signal from a multi-channel maternal AECG. The method begins by applying filters and signal detrending the AECG signals. Afterwards, the maternal QRS complexes are identified and subtracted. The residual signals are used to detect the fetal QRS complex. Intervals of these signals are analyzed by using a wavelet decomposition. The resulting representation feds a previously trained Random Forest (RF) classifier that identifies signal intervals associated to fetal QRS complex. The method was evaluated on a public available dataset: the Physionet2013 challenge. A set of 50 maternal AECG records were used to train the RF classifier. The evaluation was carried out in signals intervals extracted from additional 25 maternal AECG. The proposed method yielded an 83:77% accuracy in the fetal QRS complex classification task.

  8. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  9. Swallowable capsule with air channel for improved image-guided cancer detection in the esophagus

    Science.gov (United States)

    Seibel, Eric J.; Melville, C. David; Lung, Jonathan K. C.; Babchanik, Alexander P.; Lee, Cameron M.; Johnston, Richard S.; Dominitz, Jason A.

    2009-02-01

    A new type of endoscope has been developed and tested in the human esophagus, a tethered-capsule endoscope (TCE) that requires no sedation for oral ingestion and esophageal inspection. The TCE uses scanned red, green, and blue laser light to image the upper digestive tract using a swallowable capsule of 6.4mm in diameter and 18mm in length on a 1.4mm diameter tether. The TCE has been modified for image-guided interventions in the lower esophagus, specifically for more effective detection and measurement of the extent of Barrett's esophagus, a precursor to esophageal cancer. Three modifications have been tested in vivo: (1) weighting the capsule so it is negatively buoyant in water, (2) increasing the frame rate of 500-line images to 30 Hz (video rate), and (3) adding a 1.0mm inner diameter working channel alongside the tether for distending the lower esophagus with air pressure during endoscopy. All three modifications proved effective for more clearly visualizing the lower esophagus in the first few human subjects. The air channel was especially useful because it did not change tolerability in the first subject for unsedated endoscopy and the air easily removed bubbles obscuring tissue from the field of view. The air provided a non-invasive intervention by stimulating the mechanosensor of the lower esophageal sphincter at the precise time that the TCE was positioned for most informative imaging. All three TCE modifications proved successful for improved visualization of esophageal pathology, such as suspected Barrett's esophagus, without the use of sedation.

  10. Multipass Channel Estimation and Joint Multiuser Detection and Equalization for MIMO Long-Code DS/CDMA Systems

    Directory of Open Access Journals (Sweden)

    Buzzi Stefano

    2006-01-01

    Full Text Available The problem of joint channel estimation, equalization, and multiuser detection for a multiantenna DS/CDMA system operating over a frequency-selective fading channel and adopting long aperiodic spreading codes is considered in this paper. First of all, we present several channel estimation and multiuser data detection schemes suited for multiantenna long-code DS/CDMA systems. Then, a multipass strategy, wherein the data detection and the channel estimation procedures exchange information in a recursive fashion, is introduced and analyzed for the proposed scenario. Remarkably, this strategy provides, at the price of some attendant computational complexity increase, excellent performance even when very short training sequences are transmitted, and thus couples together the conflicting advantages of both trained and blind systems, that is, good performance and no wasted bandwidth, respectively. Space-time coded systems are also considered, and it is shown that the multipass strategy provides excellent results for such systems also. Likewise, it is also shown that excellent performance is achieved also when each user adopts the same spreading code for all of its transmit antennas. The validity of the proposed procedure is corroborated by both simulation results and analytical findings. In particular, it is shown that adopting the multipass strategy results in a remarkable reduction of the channel estimation mean-square error and of the optimal length of the training sequence.

  11. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  12. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  13. Detection of intracranial aneurysms with 64 channel multidetector row computed tomography: Comparison with digital subtraction angiography

    International Nuclear Information System (INIS)

    Pozzi-Mucelli, Fabio; Bruni, Stefano; Doddi, Marco; Calgaro, Antonio; Braini, Massimiliano; Cova, Maria

    2007-01-01

    Purpose: To compare the contribution of 64 channel multidetector row computed tomography angiography (64MDCT-angiography) with digital subtraction angiography (DSA) in the detection of intracranial aneurysms. Methods and materials: Twenty-nine patients (10 males and 19 females, age: 40-84 years; average: 61.9 years) with clinical and imaging findings strongly suggesting the presence of subaracnoid hemorrhage underwent 64MDCT-angiography and DSA with a short interval between the two examinations (less than 12 h-5 days). CT parameters were: 64 mm x 0.5 mm collimation, pitch-0.828 and helical pitch-53. DSA were performed with standard technique (four vessel catheterization) and multiple projections. Axial CT scans as well as maximum intensity projection, volume rendering and multiplanar reformations and angiographic views were independently reviewed by four readers (two for 64MDCT-angiography and two for DSA). Consensus was reached for discordant cases. DSA was considered as the standard of reference. Results: In 29 patients, 28 aneurysms were found (14 patients had 1 aneurysm, 4 patients had 2 aneurysms and 2 patients had 3 aneurysms; in 9 patients no aneurysm were found). 64MDCT-angiography detected 26/28 aneurysms. No false-positive sites were recognized. The sensitivity, specificity, positive and negative predictive values and diagnostic accuracy were, respectively, 92.8, 100, 100, 99.4 and 99.5%. Conclusions: 64MDCT-angiography is helpful in detecting intracranial aneurysms with results similar to those of DSA but with less discomfort and risks for the patients and can be considered for the first line imaging technique. Conventional angiography is still needed in doubtful cases or negative MDCT-angiography associated with a strong clinical suspect

  14. Unconventional signal detection techniques with Gaussian probability mixtures adaptation in non-AWGN channels: full resolution receiver

    Science.gov (United States)

    Chabdarov, Shamil M.; Nadeev, Adel F.; Chickrin, Dmitry E.; Faizullin, Rashid R.

    2011-04-01

    In this paper we discuss unconventional detection technique also known as «full resolution receiver». This receiver uses Gaussian probability mixtures for interference structure adaptation. Full resolution receiver is alternative to conventional matched filter receivers in the case of non-Gaussian interferences. For the DS-CDMA forward channel with presence of complex interferences sufficient performance increasing was shown.

  15. The Use of Low-frequency Active Channel Signals in an Information Leakage Detection and Prevention Systems

    Directory of Open Access Journals (Sweden)

    A. V. Mamaev

    2011-06-01

    Full Text Available This article describes a solution for the protection of the temporary lifting of control over the target machine, while using information leakage detection and prevention systems. It is proposed to use a specially designed channel for alert’s signals through the computer’s power supply.

  16. The Hardware and Software Implementation of Low-Frequency Active Channel Signals in an Information Leakage Detection and Prevention Systems

    Directory of Open Access Journals (Sweden)

    A. V. Mamaev

    2011-12-01

    Full Text Available This article discusses a new way of developing a special channel for the alarms, through computer’s power supply network, to solve the problem of protection from removal of the temporary control over the victim’s machine, using information leakage detection and prevention systems.

  17. On the Capacity Region of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2015-08-11

    The capacity of the intensity-modulation direct-detection free-space optical broadcast channel (OBC) is investigated. The Gaussian model with input-independent Gaussian noise is used, with both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans\\' approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian distributions or discrete distributions. While the discrete input distribution achieves higher rates than the truncated-Gaussian distribution, the latter allows expressing the achievable rate region in a closed form. At high signal-to-noise ratio (SNR), it is shown that the truncated-Gaussian distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows large. It also achieves the capacity region within a constant gap, which depends on the number of users. At low SNR, it is shown that on-off keying with time-division multiple-access (TDMA) is optimal, as it achieves any point on the boundary of the developed outer bound. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves a fairly good performance in terms of symmetric rate.

  18. Single-channel in-ear-EEG detects the focus of auditory attention to concurrent tone streams and mixed speech

    Science.gov (United States)

    Fiedler, Lorenz; Wöstmann, Malte; Graversen, Carina; Brandmeyer, Alex; Lunner, Thomas; Obleser, Jonas

    2017-06-01

    Objective. Conventional, multi-channel scalp electroencephalography (EEG) allows the identification of the attended speaker in concurrent-listening (‘cocktail party’) scenarios. This implies that EEG might provide valuable information to complement hearing aids with some form of EEG and to install a level of neuro-feedback. Approach. To investigate whether a listener’s attentional focus can be detected from single-channel hearing-aid-compatible EEG configurations, we recorded EEG from three electrodes inside the ear canal (‘in-Ear-EEG’) and additionally from 64 electrodes on the scalp. In two different, concurrent listening tasks, participants (n  =  7) were fitted with individualized in-Ear-EEG pieces and were either asked to attend to one of two dichotically-presented, concurrent tone streams or to one of two diotically-presented, concurrent audiobooks. A forward encoding model was trained to predict the EEG response at single EEG channels. Main results. Each individual participants’ attentional focus could be detected from single-channel EEG response recorded from short-distance configurations consisting only of a single in-Ear-EEG electrode and an adjacent scalp-EEG electrode. The differences in neural responses to attended and ignored stimuli were consistent in morphology (i.e. polarity and latency of components) across subjects. Significance. In sum, our findings show that the EEG response from a single-channel, hearing-aid-compatible configuration provides valuable information to identify a listener’s focus of attention.

  19. Experimental investigations concerning the suitability of channel systems for liner leak detection and drainage of a prestressed concrete vessel

    International Nuclear Information System (INIS)

    Nickel, M.; Breitbach, G.; Altes, J.; Escherich, K.H.; Wolters, J.

    1985-02-01

    The iternal surfaces of prestressed concrete pressure vessels are fitted with a steel liner to preserve the gas tightness of the primary circuit. Because of the high quality manufacture and the loading conditions a linear failure can be practically excluded. However, if it is hypothetically assumed, that a leak develops during reactor operation, it may be difficult to determine the position of the leak, because the linear area is very large. For tightness surveillance and for venting channel systems installed in close proximity to the linear are suitable. The suitability of such channels for leak detection, localisation and venting was investigated experimentally. A concrete wall (length 2.5 m, height 2.0 m, thickness 0.5 m) was constructed, covered on one side with a steel liner. Behind the liner two different channel systems have been installed. For the simulation of leaks holes were drilled into the liner. The experimental programm contained the following measurements: determination of gas flow rates into the different leaks, distribution of leakage gas over the array of channels and determination of pressures into the concrete and immediately behind the liner. The experiments have shown, that channel arrays immediately adjacent to the liner are the most suitable systems for localisation and controlled exhaust of leakage gas. The suitability decreases, if the channels are set into the concrete somewhat distant from the liner. (orig.) [de

  20. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  1. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  2. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  3. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  4. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  5. Development of an acoustic emission equipment for valves of the Nuclear Power Station Atucha 1

    International Nuclear Information System (INIS)

    Giaccheta, R.; Lopez Pumarega, I.; Straus, A.; Ruzzante, J.; Herzovich, P.

    1994-01-01

    A four channel Acoustic Emission was developed by the Acoustic Emission Group, INEND Department, of the Atomic Energy Commission of Argentina, for the detection of leaks in valves of the pressurized air system: ''Sistema de desconexion de emergencias por acido deuteroborico''. Basically, the system consists of four piezoelectric transducers with their corresponding preamplifiers coupled to the piping close to the valves. The following stages: amplifiers, threshold levels, channel identifications and visual alarm system are gathered in a box. The system was installed in the controlled zone of the Nuclear Power Stations Atucha I. It was calibrated and works on line. The values shown on the display are registered daily in order to separate the normal values from the leak ones. (author). 4 refs, 9 figs

  6. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  7. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  8. Automatic detection of buried channel deposits from dense laser altimetry data

    NARCIS (Netherlands)

    Possel, B.M.J.; Lindenbergh, R.C.; Storms, J.E.A.

    2010-01-01

    The formation of the current Rhine-Meuse delta mainly took place during the last 12 000 years. Consecutive avulsions, i.e. sudden changes in the course of river channels, resulted in a complicated pattern of sandy channel deposits, surrounded by peat and clay. Knowledge of this pattern is not only

  9. Code-Aided Estimation and Detection on Time-Varying Correlated Mimo Channels: A Factor Graph Approach

    Directory of Open Access Journals (Sweden)

    Simoens Frederik

    2006-01-01

    Full Text Available This paper concerns channel tracking in a multiantenna context for correlated flat-fading channels obeying a Gauss-Markov model. It is known that data-aided tracking of fast-fading channels requires a lot of pilot symbols in order to achieve sufficient accuracy, and hence decreases the spectral efficiency. To overcome this problem, we design a code-aided estimation scheme which exploits information from both the pilot symbols and the unknown coded data symbols. The algorithm is derived based on a factor graph representation of the system and application of the sum-product algorithm. The sum-product algorithm reveals how soft information from the decoder should be exploited for the purpose of estimation and how the information bits can be detected. Simulation results illustrate the effectiveness of our approach.

  10. A Multi-Functional Microelectrode Array Featuring 59760 Electrodes, 2048 Electrophysiology Channels, Stimulation, Impedance Measurement and Neurotransmitter Detection Channels.

    Science.gov (United States)

    Dragas, Jelena; Viswam, Vijay; Shadmani, Amir; Chen, Yihui; Bounik, Raziyeh; Stettler, Alexander; Radivojevic, Milos; Geissler, Sydney; Obien, Marie; Müller, Jan; Hierlemann, Andreas

    2017-06-01

    Biological cells are characterized by highly complex phenomena and processes that are, to a great extent, interdependent. To gain detailed insights, devices designed to study cellular phenomena need to enable tracking and manipulation of multiple cell parameters in parallel; they have to provide high signal quality and high spatiotemporal resolution. To this end, we have developed a CMOS-based microelectrode array system that integrates six measurement and stimulation functions, the largest number to date. Moreover, the system features the largest active electrode array area to date (4.48×2.43 mm 2 ) to accommodate 59,760 electrodes, while its power consumption, noise characteristics, and spatial resolution (13.5 μm electrode pitch) are comparable to the best state-of-the-art devices. The system includes: 2,048 action-potential (AP, bandwidth: 300 Hz to 10 kHz) recording units, 32 local-field-potential (LFP, bandwidth: 1 Hz to 300 Hz) recording units, 32 current recording units, 32 impedance measurement units, and 28 neurotransmitter detection units, in addition to the 16 dual-mode voltage-only or current/voltage-controlled stimulation units. The electrode array architecture is based on a switch matrix, which allows for connecting any measurement/stimulation unit to any electrode in the array and for performing different measurement/stimulation functions in parallel.

  11. Interfacing microfluidic handling with spectroscopic detection for real-life applications via the lab-on-valve platform: A review

    DEFF Research Database (Denmark)

    Hansen, Elo Harald; Miró, Manuel

    2008-01-01

    with syringe pump propelling devices as a front end to a plethora of spectroscopic detection schemes including UV-Vis spectroscopy, spectrofluorimetry, chemiluminescence, AAS, AFS and ICP-AES/MS. In contrast to lab-on-a-chip units, the versatile configuration of the micromachined LOV readily facilitates...

  12. Redox-Magnetohydrodynamic Microfluidics Without Channels and Compatible with Electrochemical Detection Under Immunoassay Conditions

    Science.gov (United States)

    Weston, Melissa C.; Nash, Christena K.; Fritsch, Ingrid

    2010-01-01

    A unique capability of redox-magnetohydrodynamics (redox-MHD) for handling liquids on a small scale was demonstrated. A 1.2-μL solution plug was pumped from an injection site to a detector without the need for a channel to direct the flow. The redox pumping species did not interfere with enzymatic activity in a solution compatible with enzyme-linked immunoassays. Alkaline phosphatase (AP), a common enzyme label, converted p-aminophenyl phosphate (PAPP) to p-aminophenol (PAPR) in the presence of 2.5 mM Ru(NH3)6Cl2 and 2.5 mM Ru(NH3)6 Cl3, in 0.1 M Tris buffer (pH=9). A solution plug containing PAPP (no AP) was pumped through the surrounding solution containing AP (no PAPP), and the enzymatically-generated PAPR was easily detected and distinguishable electrochemically from the pumping species with square wave voltammetry down to 0.1 mM concentrations. The test device consisted of a silicon chip containing individually-addressable microband electrodes, placed on a 0.5-T NdFeB permanent magnet with the field oriented perpendicular to the chip. A 8.0-mm wide × 15.5-mm long × 1.5-mm high volume of solution was contained by a poly(dimethylsiloxane) gasket and capped with a glass slide. A steady-state fluid velocity of ~30 μm/s was generated in a reinforcing flow configuration between oppositely polarized sets of pumping electrodes with ~2.1 μA. PMID:20681513

  13. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  14. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  15. Detectability index of differential phase contrast CT compared with conventional CT: a preliminary channelized Hotelling observer study

    Science.gov (United States)

    Tang, Xiangyang; Yang, Yi; Tang, Shaojie

    2013-03-01

    Under the framework of model observer with signal and background exactly known (SKE/BKE), we investigate the detectability of differential phase contrast CT compared with that of the conventional attenuation-based CT. Using the channelized Hotelling observer and the radially symmetric difference-of-Gaussians channel template , we investigate the detectability index and its variation over the dimension of object and detector cells. The preliminary data show that the differential phase contrast CT outperforms the conventional attenuation-based CT significantly in the detectability index while both the object to be detected and the cell of detector used for data acquisition are relatively small. However, the differential phase contrast CT's dominance in the detectability index diminishes with increasing dimension of either object or detector cell, and virtually disappears while the dimension of object or detector cell approaches a threshold, respectively. It is hoped that the preliminary data reported in this paper may provide insightful understanding of the differential phase contrast CT's characteristic in the detectability index and its comparison with that of the conventional attenuation-based CT.

  16. Quantification of Aortic Valve Calcifications Detected During Lung Cancer-Screening CT Helps Stratify Subjects Necessitating Echocardiography for Aortic Stenosis Diagnosis.

    Science.gov (United States)

    Lee, Hee Young; Kim, Sung Mok; Lee, Kyung Soo; Park, Seung Woo; Chung, Myung Jin; Cho, Hyoun; Jung, Jung Im; Jang, Hye Won; Jung, Sin-Ho; Goo, Juna

    2016-05-01

    No study has been published on aortic valve calcification (AVC) extent at lung cancer screening low-dose CT (LDCT) and its relationship with aortic stenosis (AS). The purpose of this study was to estimate the cutoff value of AVC on LDCT for detecting AS in asymptomatic Asian subjects. Six thousand three hundred thirty-eight subjects (mean age, 55.9 years ± 8.6) self-referred to health-promotion center underwent LDCT, coronary calcium scoring CT (CSCT), and echocardiography. AVC was quantified using Agatston methods on CT. AVC extent on LDCT was compared with that on CSCT, and AVC threshold for diagnosing AS was calculated. Clinical factors associated with AS and AVC were sought.AVC was observed in 403 subjects (64.9 years ± 8.7) on LDCT (6.4%), and AVC score measured from LDCT showed strong positive correlation with that from CSCT (r = 0.83, P AVC score for detecting AS was 138.37 with sensitivity of 90.0% and specificity 83.2%. On multivariate analysis, age (odds ratio [OR] = 1.10, 95% CI: 1.09-1.12) and hypertension (OR = 1.39, 95% CI: 1.10-1.76) were associated with the presence of AVC, whereas AVC extent at LDCT (OR = 104.32, 95% CI: 16.16-673.70) was the only significant clinical factor associated with AS; AVC extent on LDCT (OR = 104.32, 95% CI: 16.16-673.70) was the significant clinical factor associated with AS.The AVC extent on LDCT is significantly related to the presence of AS, and we recommend echocardiography for screening AS based on quantified AVC values on LDCT.

  17. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  18. Highly Sensitive Multi-Channel IDC Sensor Array for Low Concentration Taste Detection

    Directory of Open Access Journals (Sweden)

    Md. Rajibur Rahaman Khan

    2015-06-01

    Full Text Available In this study, we designed and developed an interdigitated capacitor (IDC-based taste sensor array to detect different taste substances. The designed taste sensing array has four IDC sensing elements. The four IDC taste sensing elements of the array are fabricated by incorporating four different types of lipids into the polymer, dioctyl phenylphosphonate (DOPP and tetrahydrofuran (THF to make the respective dielectric materials that are individually placed onto an interdigitated electrode (IDE via spin coating. When the dielectric material of an IDC sensing element comes into contact with a taste substance, its dielectric properties change with the capacitance of the IDC sensing element; this, in turn, changes the voltage across the IDC, as well as the output voltage of each channel of the system. In order to assess the effectiveness of the sensing system, four taste substances, namely sourness (HCl, saltiness (NaCl, sweetness (glucose and bitterness (quinine-HCl, were tested. The IDC taste sensor array had rapid response and recovery times of about 12.9 s and 13.39 s, respectively, with highly stable response properties. The response property of the proposed IDC taste sensor array was linear, and its correlation coefficient R2 was about 0.9958 over the dynamic range of the taste sensor array as the taste substance concentration was varied from 1 μM to 1 M. The proposed IDC taste sensor array has several other advantages, such as real-time monitoring capabilities, high sensitivity 45.78 mV/decade, good reproducibility with a standard deviation of about 0.029 and compactness, and the circuitry is based on readily available and inexpensive electronic components. The proposed IDC taste sensor array was compared with the potentiometric taste sensor with respect to sensitivity, dynamic range width, linearity and response time. We found that the proposed IDC sensor array has better performance. Finally, principal component analysis (PCA was applied

  19. Designed pneumatic valve actuators for controlled droplet breakup and generation.

    Science.gov (United States)

    Choi, Jae-Hoon; Lee, Seung-Kon; Lim, Jong-Min; Yang, Seung-Man; Yi, Gi-Ra

    2010-02-21

    The dynamic breakup of emulsion droplets was demonstrated in double-layered microfluidic devices equipped with designed pneumatic actuators. Uniform emulsion droplets, produced by shearing at a T-junction, were broken into smaller droplets when they passed downstream through constrictions formed by a pneumatically actuated valve in the upper control layer. The valve-assisted droplet breakup was significantly affected by the shape and layout of the control valves on the emulsion flow channel. Interestingly, by actuating the pneumatic valve immediately above the T-junction, the sizes of the emulsion droplets were controlled precisely in a programmatic manner that produced arrays of uniform emulsion droplets in various sizes and dynamic patterns.

  20. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  1. The detection of hard x-rays (10-140 KeV) by channel plate electron multipliers

    International Nuclear Information System (INIS)

    Bateman, J.E.

    1976-12-01

    Results are presented indicating that hard X-rays in the energy range 10 to 50 keV can be detected with good efficiency (5 to 10%) in channel plate electron multipliers (CPEM). From 50 keV to 140 keV the detection efficiency lies in the range 1 to 2%. A simple physical model is developed which indicates that not only can good detection efficiency be obtained but that very good X-ray imaging is possible. The model predicts that with further development, a wideband, hard X-ray detector can be realised with a detection efficiency in the range 5 to 20% and spatial response better than 10 lp/mm in the energy range 10 to 140 keV. (author)

  2. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  3. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  4. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  5. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  6. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  7. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  8. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  9. Wall to membrane linkers, stretch activated channels, and the detection of tension, voltage, temperature, auxin, and pH

    Science.gov (United States)

    Pickard, B. G.

    1992-01-01

    Introduction. The higher plant is a heterogeneous, mechanically prestressed structure continually subject to shifting forces. When a cell grows in a plant at gravitropic equilibrium, it must create localized maxima of shear in walls of neighboring cells. Such mechanical stress and strain are likely detected in a variety of ways. However, tension-sensitive ion channels are of particular interest because it appears that they are elaborately evolved for sensory function. We hypothesize that 1) the patchy patterns of high shear are focused via wall-to-membrane linkers onto the plasma membrane, where 2) they are translated by mechanosensory cation channels into corresponding patterns of high cytosolic Ca2+, which 3) initiate local enhancement of wall expansion. Further, we hypothesize that the local promotion of enhancement is achieved at least in part by local intensification of auxin transport across the plasma membrane. By implication, when an organ is asymmetrically pressed, rubbed, or bent or when it is displaced in the gravitational field, the net asymmetry of shear stress occurring across the organ would lead to asymmetric redistribution of auxin and corrective asymmetric growth. We shall describe a representative mechanosensitive Ca(2+) -selective cation channel (MCaC) with susceptibilities to xenobiotics implicating it as a force transducer in thigmo- and gravitropism. Then, we shall consider whether a putative wall-to-membrane linker (WML) could be a key feature of the molecular architecture permitting the stress distributed in the wall system to be focused on the channels.

  10. Motor operated valve stroke timing; is there value?

    International Nuclear Information System (INIS)

    Green, K.; Rosch, F. Jr.; Neckowicz, T.

    1990-01-01

    Both ASME Section XI, Subsection IWV and ASME/ANSI OMa-1988, Part 10 require stroke timing of certain power operated valves. This requirement is intended to detect valve degradation and subsequent maintenance, repair or replacement needs. However, the adequacy of stroke timing, especially for motor operated valves, has met much skepticism in the industry. This paper will demonstrate that stroke timing for ac motor operated valves is inadequate and provide a non-intrusive testing alternative. It will also discuss the value of stroke timing for dc motor operated valves

  11. Dual channel detection of ultra low concentration of bacteria in real time by scanning fluorescence correlation spectroscopy

    Science.gov (United States)

    Altamore, Ilaria; Lanzano, Luca; Gratton, Enrico

    2013-06-01

    We describe a novel method to detect very low concentrations of bacteria in water. Our device consists of a portable horizontal geometry small confocal microscope with large pinhole and a holder for cylindrical cuvettes containing the sample. Two motors provide fast rotational and slow vertical motion of the cuvette so the device looks like a simplified flow cytometer without flow. To achieve high sensitivity, the design has two detection channels. Bacteria are stained by two different nucleic acid dyes and excited with two different lasers. Data are analyzed with a correlation filter based on particle passage pattern recognition. The passage of a particle through the illumination volume is compared with a Gaussian pattern in both channels. The width of the Gaussian correlates with the time of passage of the particle so one particle is counted when the algorithm finds a match with a Gaussian in both channels. The concentration of particles in the sample is deduced from the total number of coincident hits and the total volume scanned. This portable setup provides higher sensitivity, low-cost advantage, and it can have a wide use ranging from clinical applications to pollution monitors and water and air quality control.

  12. Dual channel detection of ultra low concentration of bacteria in real time by scanning fluorescence correlation spectroscopy

    International Nuclear Information System (INIS)

    Altamore, Ilaria; Lanzano, Luca; Gratton, Enrico

    2013-01-01

    We describe a novel method to detect very low concentrations of bacteria in water. Our device consists of a portable horizontal geometry small confocal microscope with large pinhole and a holder for cylindrical cuvettes containing the sample. Two motors provide fast rotational and slow vertical motion of the cuvette so the device looks like a simplified flow cytometer without flow. To achieve high sensitivity, the design has two detection channels. Bacteria are stained by two different nucleic acid dyes and excited with two different lasers. Data are analyzed with a correlation filter based on particle passage pattern recognition. The passage of a particle through the illumination volume is compared with a Gaussian pattern in both channels. The width of the Gaussian correlates with the time of passage of the particle so one particle is counted when the algorithm finds a match with a Gaussian in both channels. The concentration of particles in the sample is deduced from the total number of coincident hits and the total volume scanned. This portable setup provides higher sensitivity, low-cost advantage, and it can have a wide use ranging from clinical applications to pollution monitors and water and air quality control. (paper)

  13. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  14. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  15. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  16. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  17. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  18. Modeling of Dynamic Fluid Forces in Fast Switching Valves

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik Clemmensen

    2015-01-01

    Switching valves experience opposing fluid forces due to movement of the moving member itself, as the surrounding fluid volume must move to accommodate the movement. This movement-induced fluid force may be divided into three main components; the added mass term, the viscous term and the socalled...... history term. For general valve geometries there are no simple solution to either of these terms. During development and design of such switching valves, it is therefore, common practice to use simple models to describe the opposing fluid forces, neglecting all but the viscous term which is determined...... based on shearing areas and venting channels. For fast acting valves the opposing fluid force may retard the valve performance significantly, if appropriate measures are not taken during the valve design. Unsteady Computational Fluid Dynamics (CFD) simulations are available to simulate the total fluid...

  19. All in the family: matrimonial mitral valve clicks.

    Science.gov (United States)

    Desser, K B; Bokhari, S I; Benchimol, A; Romney, D

    1981-05-01

    Mitral valve clicks with or without late systolic murmurs were detected in genetically unrelated marital partners of 5 families. The first family represented 2 successive nonconsanguineous marital unions with 3 generations of mitral valve clicks. The second family included 1 natural and 2 adopted children with clinical and echographic evidence of mitral valve prolapse. The third family was comprised of asymptomatic parents, both with nonejection clicks and mitral valve prolapse, whose daughter presented 3 years previously with syncope, palpitations, and combined mitral and tricuspid valve prolapse. The fourth family had 3 members with auscultatory and ultrasonic manifestations of billowing mitral valve, whereas the fourth member had "silent mitral valve prolapse." The fifth family represented a mother with auscultatory and echographic evidence of mitral valve prolapse; her 14-year-old daughter had both mitral and tricuspid valve prolapse, whereas the son had a bicuspid aortic valve. Both children were products of a prior marriage, and her husband has symptomatic mitral valve prolapse. We conclude that matrimonial mitral valve prolapse probably reflects the purported (6--10%) prevalence of this disorder in the general population. The consequences of such marital union on progeny is currently unclear and warrants future investigation.

  20. Detect-and-forward in two-hop relay channels: a metrics-based analysis

    KAUST Repository

    Benjillali, Mustapha; Szczecinski, Leszek

    2010-01-01

    In this paper, we analyze the coded performance of a cooperative system with multiple parallel relays using "Detect-and-Forward" (DetF) strategy where each relay demodulates the overheard signal and forwards the detected binary words. The proposed

  1. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  2. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  3. Mining the IPTV Channel Change Event Stream to Discover Insight and Detect Ads

    Directory of Open Access Journals (Sweden)

    Matej Kren

    2016-01-01

    Full Text Available IPTV has been widely deployed throughout the world, bringing significant advantages to users in terms of the channel offering, video on demand, and interactive applications. One aspect that has been often neglected is the ability of precise and unobtrusive telemetry. TV set-top boxes that are deployed in modern IPTV systems can be thought of as capable sensor nodes that collect vast amounts of data, representing both the user activity and the quality of service delivered by the system itself. In this paper we focus on the user-generated events and analyze how the data stream of channel change events received from the entire IPTV network can be mined to obtain insight about the content. We demonstrate that it is possible to predict the occurrence of TV ads with high probability and show that the approach could be extended to model the user behavior and classify the viewership in multiple dimensions.

  4. Transient Receptor Potential Canonical 3 (TRPC3) Channels Are Required for Hypothalamic Glucose Detection and Energy Homeostasis.

    Science.gov (United States)

    Chrétien, Chloé; Fenech, Claire; Liénard, Fabienne; Grall, Sylvie; Chevalier, Charlène; Chaudy, Sylvie; Brenachot, Xavier; Berges, Raymond; Louche, Katie; Stark, Romana; Nédélec, Emmanuelle; Laderrière, Amélie; Andrews, Zane B; Benani, Alexandre; Flockerzi, Veit; Gascuel, Jean; Hartmann, Jana; Moro, Cédric; Birnbaumer, Lutz; Leloup, Corinne; Pénicaud, Luc; Fioramonti, Xavier

    2017-02-01

    The mediobasal hypothalamus (MBH) contains neurons capable of directly detecting metabolic signals such as glucose to control energy homeostasis. Among them, glucose-excited (GE) neurons increase their electrical activity when glucose rises. In view of previous work, we hypothesized that transient receptor potential canonical type 3 (TRPC3) channels are involved in hypothalamic glucose detection and the control of energy homeostasis. To investigate the role of TRPC3, we used constitutive and conditional TRPC3-deficient mouse models. Hypothalamic glucose detection was studied in vivo by measuring food intake and insulin secretion in response to increased brain glucose level. The role of TRPC3 in GE neuron response to glucose was studied by using in vitro calcium imaging on freshly dissociated MBH neurons. We found that whole-body and MBH TRPC3-deficient mice have increased body weight and food intake. The anorectic effect of intracerebroventricular glucose and the insulin secretory response to intracarotid glucose injection are blunted in TRPC3-deficient mice. TRPC3 loss of function or pharmacological inhibition blunts calcium responses to glucose in MBH neurons in vitro. Together, the results demonstrate that TRPC3 channels are required for the response to glucose of MBH GE neurons and the central effect of glucose on insulin secretion and food intake. © 2017 by the American Diabetes Association.

  5. Multi-geophysical approaches to detect karst channels underground - A case study in Mengzi of Yunnan Province, China

    Science.gov (United States)

    Gan, Fuping; Han, Kai; Lan, Funing; Chen, Yuling; Zhang, Wei

    2017-01-01

    Mengzi locates in the south 20 km away from the outlet of Nandong subsurface river, and has been suffering from water deficiency in recent years. It is necessary to find out the water resources underground according to the geological characteristics such as the positions and buried depths of the underground river to improve the civil and industrial environments. Due to the adverse factors such as topographic relief, bare rocks in karst terrains, the geophysical approaches, such as Controlled Source Audio Magnetotellurics and Seismic Refraction Tomography, were used to roughly identify faults and fracture zones by the geophysical features of low resistivity and low velocity, and then used the mise-a-la-masse method to judge which faults and fracture zones should be the potential channels of the subsurface river. Five anomalies were recognized along the profile of 2.4 km long and showed that the northeast river system has several branches. Drilling data have proved that the first borehole indicated a water bearing channel by a characteristics of rock core of river sands and gravels deposition, the second one encountered water-filled fracture zone with abundant water, and the third one exposed mud-filled fracture zone without sustainable water. The results from this case study show that the combination of Controlled Source Audio Magnetotellurics, Seismic Refraction Tomography and mise-a-la-Masse is one of the effective methods to detect water-filled channels or fracture zones in karst terrains.

  6. Improved bacteria detection by coupling magneto-immunocapture and amperometry at flow-channel microband electrodes

    DEFF Research Database (Denmark)

    Laczka, Olivier; Maesa, José-María; Godino, Neus

    2011-01-01

    This paper describes the first immunosensing system reported for the detection of bacteria combining immunomagnetic capture and amperometric detection in a one-step sandwich format, and in a microfluidic environment. Detection is based on the electrochemical monitoring of the activity of horserad......This paper describes the first immunosensing system reported for the detection of bacteria combining immunomagnetic capture and amperometric detection in a one-step sandwich format, and in a microfluidic environment. Detection is based on the electrochemical monitoring of the activity...... product is then pumped along a microchannel, where it is amperometrically detected by a set of microelectrodes. This design avoids direct contact of the biocomponents with the electrode, which lowers the risk of electrode fouling. The whole assay can be completed in 1h. The experiments performed...... with Escherichia coli evidenced a linear response for concentrations ranging 102–108cellml−1, with a limit of detection of 55cellsml−1 in PBS, without pre-enrichment steps. Furthermore, 100cellsml−1 could be detected in milk, and with negligible interference by non-target bacteria such as Pseudomonas....

  7. Operational durability of a giant ER valve for Braille display

    Science.gov (United States)

    Luning, Xu; Han, Li; Yufei, Li; Shen, Rong; Kunquan, Lu

    2017-05-01

    The compact configuration of giant ER (electrorheological) valves provides the possibility of realizing a full-page Braille display. The operational durability of ER valves is a key issue in fulfilling a Braille display. A giant ER valve was used to investigate the variations in pressure drops and critical pressure drops of the valves over a long period under some typical operational parameters. The results indicate that neither the pressure drops nor critical pressure drops of giant ER valves show apparent deterioration over a long period. Without ER fluid exchange, a blockage appears in the channel of the valve because the ER structures induced by an external electric field cannot be broken by the Brownian motion of hydraulic oil molecules when the external electric field is removed. Forcing ER fluid flow is an effective and necessary method to keep the channel of the valve unblocked. Thus the operational durability of the valve using giant ER fluids is able to meet the demands of Braille display.

  8. Hydrodynamic characterization of a passive shape memory alloy valve

    International Nuclear Information System (INIS)

    Waddell, A M; Punch, J; Stafford, J; Jeffers, N

    2014-01-01

    Next generation high-performance electronics will have large heat fluxes (>10 2 W/cm 2 ) and an alternative approach to traditional air cooling is required. An attractive solution is micro-channel cooling and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. A NiTi Shape Memory Alloy (SMA) micro-valve design was hydrodynamically characterized in this work to obtain the valve loss coefficient (K) from pressure measurements. The hydrodynamic characterization was important as in the flow regime of the micro-fluidic system K is sensitive to Reynolds number (Re) and geometry. Static replicas of the SMA valve geometry were studied for low Reynolds numbers (110 – 220) in a 1x1 mm CSA miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. The SMA valve was compared to a similar gate micro-valve and loss across both valves was of the same order of magnitude. The valve loss coefficients obtained in this work are important parameters in the modeling and design of micro-fluidic cooling systems.

  9. Magnon Valve Effect between Two Magnetic Insulators

    Science.gov (United States)

    Wu, H.; Huang, L.; Fang, C.; Yang, B. S.; Wan, C. H.; Yu, G. Q.; Feng, J. F.; Wei, H. X.; Han, X. F.

    2018-03-01

    The key physics of the spin valve involves spin-polarized conduction electrons propagating between two magnetic layers such that the device conductance is controlled by the relative magnetization orientation of two magnetic layers. Here, we report the effect of a magnon valve which is made of two ferromagnetic insulators (YIG) separated by a nonmagnetic spacer layer (Au). When a thermal gradient is applied perpendicular to the layers, the inverse spin Hall voltage output detected by a Pt bar placed on top of the magnon valve depends on the relative orientation of the magnetization of two YIG layers, indicating the magnon current induced by the spin Seebeck effect at one layer affects the magnon current in the other layer separated by Au. We interpret the magnon valve effect by the angular momentum conversion and propagation between magnons in two YIG layers and conduction electrons in the Au layer. The temperature dependence of the magnon valve ratio shows approximately a power law, supporting the above magnon-electron spin conversion mechanism. This work opens a new class of valve structures beyond the conventional spin valves.

  10. Syntectonic Mississippi River Channel Response: Integrating River Morphology and Seismic Imaging to Detect Active Faults

    Science.gov (United States)

    Magnani, M. B.

    2017-12-01

    Alluvial rivers, even great rivers such as the Mississippi, respond to hydrologic and geologic controls. Temporal variations of valley gradient can significantly alter channel morphology, as the river responds syntectonically to attain equilibrium. The river will alter its sinuosity, in an attempt to maintain a constant gradient on a surface that changes slope through time. Therefore, changes of river pattern can be the first clue that active tectonics is affecting an area of pattern change. Here I present geomorphological and seismic imaging evidence of a previously unknown fault crossing the Mississippi river south of the New Madrid seismic zone, between Caruthersville, Missouri and Osceola, Arkansas, and show that both datasets support Holocene fault movement, with the latest slip occurring in the last 200 years. High resolution marine seismic reflection data acquired along the Mississippi river imaged a NW-SE striking north-dipping fault displacing the base of the Quaternary alluvium by 15 m with reverse sense of movement. The fault consistently deforms the Tertiary, Cretaceous and Paleozoic formations. Historical river channel planforms dating back to 1765 reveal that the section of the river channel across the fault has been characterized by high sinuosity and steep projected-channel slope compared to adjacent river reaches. In particular, the reach across the fault experienced a cutoff in 1821, resulting in a temporary lowering of sinuosity followed by an increase between the survey of 1880 and 1915. Under the assumption that the change in sinuosity reflects river response to a valley slope change to maintain constant gradient, I use sinuosity through time to calculate the change in valley slope since 1880 and therefore to estimate the vertical displacement of the imaged fault in the past 200 years. Based on calculations so performed, the vertical offset of the fault is estimated to be 0.4 m, accrued since at least 1880. If the base of the river alluvium

  11. Collaborations on YouTube: From Unsupervised Detection to the Impact on Video and Channel Popularity

    OpenAIRE

    Koch, Christian; Lode, Moritz; Stohr, Denny; Rizk, Amr; Steinmetz, Ralf

    2018-01-01

    YouTube is one of the most popular platforms for streaming of user-generated video. Nowadays, professional YouTubers are organized in so called multi-channel networks (MCNs). These networks offer services such as brand deals, equipment, and strategic advice in exchange for a share of the YouTubers' revenue. A major strategy to gain more subscribers and, hence, revenue is collaborating with other YouTubers. Yet, collaborations on YouTube have not been studied in a detailed quantitative manner....

  12. Detection and Protection of Macro-Users in Dominant Area of Co-channel CSG Cells

    DEFF Research Database (Denmark)

    Wang, Yuanye; Pedersen, Klaus; Frederiksen, Frank

    2012-01-01

    subframes that are free of HeNB interference. Different methods for coverage hole detection are considered, and their performance is evaluated under the downlink transmission of a Long Term Evolution (LTE) network. These methods are based on user measurements. Recommendations on the coverage hole detection...

  13. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  14. Low-Complexity Full-Diversity Detection in Two-User MIMO X Channels

    KAUST Repository

    Ismail, Amr

    2014-01-26

    Several interference cancellation (IC) schemes have been recently proposed to suppress multi-user interference for various network configurations (e.g., multiple access and X channels). However, most of these schemes trade-off diversity for implementation complexity or vice-versa. In this paper, we propose a full-diversity interference cancellation scheme in a multiple-input multiple-output (MIMO) X channel with two sources and two destinations while maintaining low decoding complexity. We provide sufficient conditions for a wide range of space-time block codes (STBCs) to achieve full-diversity gain under the so-called partial interference cancellation group decoding (PICGD) in the configuration of interest. A systematic construction is then proposed to achieve full-diversity. The constructed scheme is compared to recently proposed IC scheme in terms of performance and decoding complexity. Our IC scheme outperforms the recently proposed scheme in the case it provides higher transmission rate, while it loses slightly in the case of equal rates. In terms of decoding complexity, both schemes are equivalent.

  15. Threshold-based detection for amplify-and-forward cooperative communication systems with channel estimation error

    KAUST Repository

    Abuzaid, Abdulrahman I.

    2014-09-01

    Efficient receiver designs for cooperative communication systems are becoming increasingly important. In previous work, cooperative networks communicated with the use of $L$ relays. As the receiver is constrained, it can only process $U$ out of $L$ relays. Channel shortening and reduced-rank techniques were employed to design the preprocessing matrix. In this paper, a receiver structure is proposed which combines the joint iterative optimization (JIO) algorithm and our proposed threshold selection criteria. This receiver structure assists in determining the optimal $U-{opt}$. Furthermore, this receiver provides the freedom to choose $U ≤ U-{opt}$ for each frame depending upon the tolerable difference allowed for mean square error (MSE). Our study and simulation results show that by choosing an appropriate threshold, it is possible to gain in terms of complexity savings without affecting the BER performance of the system. Furthermore, in this paper the effect of channel estimation errors is investigated on the MSE performance of the amplify-and-forward (AF) cooperative relaying system.

  16. Low-Complexity Full-Diversity Detection in Two-User MIMO X Channels

    KAUST Repository

    Ismail, Amr; Abediseid, Walid; Alouini, Mohamed-Slim

    2014-01-01

    Several interference cancellation (IC) schemes have been recently proposed to suppress multi-user interference for various network configurations (e.g., multiple access and X channels). However, most of these schemes trade-off diversity for implementation complexity or vice-versa. In this paper, we propose a full-diversity interference cancellation scheme in a multiple-input multiple-output (MIMO) X channel with two sources and two destinations while maintaining low decoding complexity. We provide sufficient conditions for a wide range of space-time block codes (STBCs) to achieve full-diversity gain under the so-called partial interference cancellation group decoding (PICGD) in the configuration of interest. A systematic construction is then proposed to achieve full-diversity. The constructed scheme is compared to recently proposed IC scheme in terms of performance and decoding complexity. Our IC scheme outperforms the recently proposed scheme in the case it provides higher transmission rate, while it loses slightly in the case of equal rates. In terms of decoding complexity, both schemes are equivalent.

  17. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  18. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  19. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  20. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  1. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  2. A CAMAC 32-channel pile-up detection and rejection module

    International Nuclear Information System (INIS)

    Wikne, J.C.

    1992-08-01

    A specially developed CAMAC module for detection and rejection of analog pile-up in multiparameter, nuclear spectroscopy experiments is described. The present report is a complete technical manual for the module. 23 refs., 6 figs

  3. Ultra-high optical responsivity of semiconducting asymmetric nano-channel diodes for photon detection

    Science.gov (United States)

    Akbas, Y.; Plecenik, T.; Durina, P.; Plecenik, A.; Jukna, A.; Wicks, G.; Sobolewski, Roman

    2017-05-01

    The asymmetric nano-channel diode (ANCD) is the 2-dimensional electron gas (2DEG) semiconductor nanodevice that, unlike a conventional diode, relies on the device nanostructure and field-controlled transport in a ballistic nanometerwidth channel instead of barriers to develop its asymmetric, diode-like current-voltage (I-V) characteristics. We focus on ANCD optoelectronic properties, and demonstrate that the devices can act as very sensitive, single-photon-level, visiblelight photodetectors. Our test structures consist of 2-μm-long and 230-nm-wide channels and were fabricated using electron-beam lithography on a GaAs/AlGaAs heterostructure with a 2DEG layer, followed by reactive ion etching. The I-V curves were collected by measuring the transport current under the voltage-source biasing condition, both in the dark and under light illumination. The experiments were conducted inside a cryostat, in a temperature range from 300 K to 78 K. As an optical excitation, we used a 800-nm-wavelength, generated by a commercial Ti:sapphire laser operated either at a quasi-continuous-wave mode or as a source of 100-fs-wide pulses. The impact of the light illumination was very clear, and at low temperatures we observed a significant photocurrent Iph 0.25 μA at temperature 78 K for the incident optical power as low as 1 nW, with a limited dark-current background. The magnitude of the device optical responsivity increased linearly with the decrease of the optical power, reaching for 1-nW optical excitation the value as high as 400 A/W at room temperature and >800 A/W at 78K. The physics of the photoresponse gain mechanism in the ANCD arises from a vast disparity between the sub-picosecond transit time of photo-excited electrons travelling in the 2DEG nanochannel and the up to microsecond lifetime of photo-excited holes pushed towards the device substrate.

  4. Selective electrochemical detection of dopamine in a microfluidic channel on carbon nanoparticulate electrodes.

    Science.gov (United States)

    Rozniecka, Ewa; Jonsson-Niedziolka, Martin; Celebanska, Anna; Niedziolka-Jonsson, Joanna; Opallo, Marcin

    2014-06-07

    There is a continuous need for the construction of detection systems in microfluidic devices. In particular, electrochemical detection allows the separation of signals from the analyte and interfering substances in the potential domain. Here, a simple microfluidic device for the sensitive and selective determination of dopamine in the presence of interfering substances was constructed and tested. It employs a carbon nanoparticulate electrode allowing the separation of voltammetric signals of dopamine and common interfering substances (ascorbic acid and acetaminophen) both in quiescent conditions and in flow due to the electrocatalytic effect. These voltammograms were also successfully simulated. The limit of detection of dopamine detected by square wave voltammetry in 1 mM solutions of interfering substances in phosphate buffered saline is about 100 nM. In human serum a clear voltammetric signal could be seen for a 200 nM solution, sufficient to detect dopamine in the cerebral fluid. Flow injection analysis allows a decrease in the limit of detection down to 3.5 nM.

  5. A high performance magnetorheological valve with a meandering flow path

    International Nuclear Information System (INIS)

    Imaduddin, Fitrian; Amri Mazlan, Saiful; Azizi Abdul Rahman, Mohd; Zamzuri, Hairi; Ubaidillah; Ichwan, Burhanuddin

    2014-01-01

    The huge developments in the field of magnetorheological (MR) fluid-based devices will have a great influence on the future of mechatronic applications due to the ease of interfacing between electronic controls and the mechanical components that they provide. Among various MR fluid-based devices, an MR valve would be particularly significant for the development of other devices, if it could be successfully achieved. One of the most challenging obstacles to MR valve development is the difficulty of achieving device miniaturization while, at the same time, improving the achievable performance. This study demonstrates a novel design for an MR valve, using the meandering flow path approach in order to increase the effective area so that the MR fluid can be regulated within a small-sized valve. The meandering flow path is formed by combining multiple annular, radial and orifice flow channels. In order to analyze the valve performance, a mathematical model of the proposed MR valve is derived and combined with numerical simulation using the finite element method, with the intention of predicting the achievable pressure drop that can be generated by the valve. The predicted MR valve performances are then experimentally evaluated using an oscillation-disturbed bypass hydraulic cylinder. The simulation results show that the proposed MR valve design could yield substantial pressure drop improvement, which is confirmed by the experiment

  6. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  7. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  8. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  9. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  10. Spin transport at high temperatures in epitaxial Heusler alloy/n-GaAs lateral spin valves

    Science.gov (United States)

    Peterson, Timothy A.; Christie, Kevin D.; Patel, Sahil J.; Crowell, Paul A.; Palmstrøm, Chris J.

    2015-03-01

    We report on electrical injection and detection of spin accumulation in ferromagnet/ n-GaAs lateral spin-valve devices, observed up to and above room temperature. The ferromagnet in these measurements is the Heusler alloy Co2FeSi, and the semiconductor channel is GaAs doped at 3 ×1016 cm-3. The spin signal is enhanced by operating the detection contact under forward bias. The enhancement originates from drift effects at low-temperatures and an increase of the detection efficiency at all temperatures. The detector bias dependence of the observed spin-valve signal is interpreted by taking into account the quantum well (QW) which forms in the degenerately doped region immediately behind the Schottky tunnel barrier. In particular, we believe the QW is responsible for the minority spin accumulation (majority spin current) under large forward bias. The spin diffusion length and lifetime are determined by measuring the separation dependence of the non-local spin valve signal in a family of devices patterned by electron beam lithography. A spin diffusion length of 700 nm and lifetime of 46 picoseconds are found at a temperature of 295 K. This work was supported by the NSF under DMR-1104951, the NSF MRSEC program and C-SPIN, a SRC STARNET center sponsored by MARCO and DARPA.

  11. Performance analysis of EM-based blind detection for ON-OFF keying modulation over atmospheric optical channels

    Science.gov (United States)

    Dabiri, Mohammad Taghi; Sadough, Seyed Mohammad Sajad

    2018-04-01

    In the free-space optical (FSO) links, atmospheric turbulence lead to scintillation in the received signal. Due to its ease of implementation, intensity modulation with direct detection (IM/DD) based on ON-OFF keying (OOK) is a popular signaling scheme in these systems. Over turbulence channel, to detect OOK symbols in a blind way, i.e., without sending pilot symbols, an expectation-maximization (EM)-based detection method was recently proposed in the literature related to free-space optical (FSO) communication. However, the performance of EM-based detection methods severely depends on the length of the observation interval (Ls). To choose the optimum values of Ls at target bit error rates (BER)s of FSO communications which are commonly lower than 10-9, Monte-Carlo simulations would be very cumbersome and require a very long processing time. To facilitate performance evaluation, in this letter we derive the analytic expressions for BER and outage probability. Numerical results validate the accuracy of our derived analytic expressions. Our results may serve to evaluate the optimum value for Ls without resorting to time-consuming Monte-Carlo simulations.

  12. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  13. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Science.gov (United States)

    López Terrones, Marcos Alonso; Solís-Nájera, Sergio Enrique

    2014-11-01

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  14. A six-channel pediatric coil array for detection of children spinal pathologies by MRI at 1.5 Tesla

    Energy Technology Data Exchange (ETDEWEB)

    López Terrones, Marcos Alonso, E-mail: malt.marcos@gmail.com [Ingeniería Biomédica, Dirección de Planeación, Servicios de Salud de Durango. Cuauhtémoc 225 Norte, Durango, Durango 34000 (Mexico); Solís-Nájera, Sergio Enrique, E-mail: solisnajera@ciencias.unam.mx [Facultad de Ciencias, Universidad Nacional Autónoma de México, México, DF 04510 (Mexico)

    2014-11-07

    Nowadays, magnetic resonance (MR) in Mexico has become a standard technique for clinical imaging. Although most of the times the MR systems contain only coils oriented for adults. Radiologists use these coils for children studies due to the non-availability of pediatric coils. Image quality is decreased due to the low signal to noise ratio delivered to the system. The development of RF coils is always focused towards increasing SNR and optimizing the RF penetration into the sample. Moreover, spinal pathologies in children, which are an important topic in pediatric care, cover congenital and neuromuscular disorders that occur in childhood. In this work, the design of a dedicated six-channel coil for detection of spinal pathologies at 1.5 Tesla is addressed. Numerical electromagnetic simulations were performed in order to evaluate their magnetic field performance at (63.6 MHz) 1.5 Tesla. The magnetic field uniformity as well as the RF penetration depth of the coil configurations was evaluated in order to find the best/optimized coil array configuration. The coil is comprised of three rows, one with 4 coil elements and two with only one coil element. Phantom and in vivo images were acquired with the six-channel pediatric coil array. The phantom images agree with the simulated data. In vivo images acquired with the 6-channel pediatric coil array have shown very good penetration depth and homogeneity, which allow better image quality throughout the whole FOV. In addition, the parallel imaging capabilities of the array allow the acceleration of the experiments avoiding possible motion artifacts.

  15. Single leg separation prevalence among explanted Björk-Shiley prosthetic heart valves.

    Science.gov (United States)

    Blot, William J; Signorello, Lisa B; Cohen, Sarah S; Ibrahim, Michel A

    2007-11-01

    Björk-Shiley convexo-concave (BSCC) prosthetic heart valves are believed to have been implanted in over 86,000 patients worldwide. Limited data are available on the prevalence of single leg separations (SLS) of the valves' outlet struts, a potential precursor to complete valve fracture. Data maintained by the manufacturer, including results of examinations for SLS in explanted valves, were merged with available information on the characteristics of the valve. The prevalence of SLS in the examined valves was calculated according to valve angle, size, position, and study. Among 343 examined valves, the overall prevalence of SLS was 8.2%, but this varied significantly by valve size, being three-fold higher among 29+ mm valves than among smaller valves, with statistically non-significantly higher prevalences among mitral than aortic, and among 70 degrees than 60 degrees valves. By applying the size, position and angle-specific SLS prevalences to the worldwide valve distribution, it is estimated that SLS may be present in 6.8% (95% confidence limits 4.1-9.4%) of all BSCC valves. These findings suggest that SLS may affect between 820 and 1,880 of the almost 20,000 BSCC valves among surviving patients worldwide. Such estimates help frame the context for potential patient screenings, should imaging and acoustic techniques to detect SLS become available.

  16. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  17. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas; Rezki, Zouheir; Alouini, Mohamed-Slim

    2016-01-01

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  18. Indirect detection constraints on s- and t-channel simplified models of dark matter

    Science.gov (United States)

    Carpenter, Linda M.; Colburn, Russell; Goodman, Jessica; Linden, Tim

    2016-09-01

    Recent Fermi-LAT observations of dwarf spheroidal galaxies in the Milky Way have placed strong limits on the gamma-ray flux from dark matter annihilation. In order to produce the strongest limit on the dark matter annihilation cross section, the observations of each dwarf galaxy have typically been "stacked" in a joint-likelihood analysis, utilizing optical observations to constrain the dark matter density profile in each dwarf. These limits have typically been computed only for singular annihilation final states, such as b b ¯ or τ+τ- . In this paper, we generalize this approach by producing an independent joint-likelihood analysis to set constraints on models where the dark matter particle annihilates to multiple final-state fermions. We interpret these results in the context of the most popular simplified models, including those with s- and t-channel dark matter annihilation through scalar and vector mediators. We present our results as constraints on the minimum dark matter mass and the mediator sector parameters. Additionally, we compare our simplified model results to those of effective field theory contact interactions in the high-mass limit.

  19. On the Capacity of the Intensity-Modulation Direct-Detection Optical Broadcast Channel

    KAUST Repository

    Chaaban, Anas

    2016-01-12

    The capacity of the intensity-modulation directdetection optical broadcast channel (OBC) is investigated, under both average and peak intensity constraints. An outer bound on the capacity region is derived by adapting Bergmans’ approach to the OBC. Inner bounds are derived by using superposition coding with either truncated-Gaussian (TG) distributions or discrete distributions. While the discrete distribution achieves higher rates, the TG distribution leads to a simpler representation of the achievable rate region. At high signal-to-noise ratio (SNR), it is shown that the TG distribution is nearly optimal. It achieves the symmetric-capacity within a constant gap (independent of SNR), which approaches half a bit as the number of users grows. It also achieves the capacity region within a constant gap. At low SNR, it is shown that on-off keying (OOK) with time-division multipleaccess (TDMA) is optimal. This is interesting in practice since both OOK and TDMA have low complexity. At moderate SNR (typically [0,8] dB), a discrete distribution with a small alphabet size achieves fairly good performance.

  20. Combining optical trapping in a microfluidic channel with simultaneous micro-Raman spectroscopy and motion detection

    Science.gov (United States)

    Lawton, Penelope F.; Saunter, Christopher D.; Girkin, John M.

    2014-03-01

    Since their invention by Ashkin optical tweezers have demonstrated their ability and versatility as a non-invasive tool for micromanipulation. One of the most useful additions to the basic optical tweezers system is micro-Raman spectroscopy, which permits highly sensitive analysis of single cells or particles. We report on the development of a dual laser system combining two spatial light modulators to holographically manipulate multiple traps (at 1064nm) whilst undertaking Raman spectroscopy using a 532nm laser. We can thus simultaneously trap multiple particles and record their Raman spectra, without perturbing the trapping system. The dual beam system is built around micro-fluidic channels where crystallisation of calcium carbonate occurs on polymethylmethacrylate (PMMA) beads. The setup is designed to simulate at a microscopic level the reactions that occur on items in a dishwasher, where permanent filming of calcium carbonate on drinking glasses is a problem. Our system allows us to monitor crystal growth on trapped particles in which the Raman spectrum and changes in movement of the bead are recorded. Due to the expected low level of crystallisation on the bead surfaces this allows us to obtain results quickly and with high sensitivity. The long term goal is to study the development of filming on samples in-situ with the microfl.uidic system acting as a model dishwasher.

  1. Fault-tolerant quantum cryptographic protocols with collective detection over the collective amplitude damping channel

    International Nuclear Information System (INIS)

    Huang, Wei; Su, Qi; Li, Yan-Bing; Sun, Ying

    2014-01-01

    In this paper, a quantum key distribution (QKD) protocol, which can be immune to collective amplitude damping noise, is proposed with collective detection strategy. Then a multi-party quantum secret sharing (MQSS) protocol and a quantum private comparison (QPC) protocol are introduced as two applications of the proposed QKD protocol. Except for one participant who is responsible for preparing and measuring quantum states, the rest of the users in each of these protocols only need to perform certain unitary operations due to the utilization of collective detection. Therefore, in addition to the advantage of being secure against collective amplitude damping noise, the proposed protocols still have the advantages of higher qubit efficiency and lower cost for implementation. Moreover, the security of these protocols is guaranteed by theorems on quantum operation discrimination. (papers)

  2. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  3. Mitral valve prolapse and hyperthyroidism: effect of patient selection.

    Science.gov (United States)

    Zullo, M A; Devereux, R B; Kramer-Fox, R; Lutas, E M; Brown, W T

    1985-11-01

    Patients with mitral valve prolapse and hyperthyroidism have common symptoms; the most outstanding symptom is palpitation. To determine whether or not common symptoms contributed to the reported association of these conditions, we evaluated 220 patients with symptomatic mitral valve prolapse and 216 first-degree relatives in 72 families; 65 relatives with mitral valve prolapse and 151 relatives without mitral valve prolapse, all greater than or equal to 16 years of age. Thirty subjects, aged 49 +/- 13 years (p less than 0.025 vs entire study group), had thyroid disease (23 subjects had definite thyroid disease, seven subjects had probable); 27 of 30 subjects with thyroid disease (90%) were female (p less than 0.005). The age- and sex-adjusted prevalence of hyperthyroidism was significantly higher in probands with mitral valve prolapse than in family members without mitral valve prolapse (3.5% vs 0%, p = 0.03), while an intermediate prevalence of hyperthyroidism (2.2%) was observed in family members with mitral valve prolapse. Thus, the prevalence of hyperthyroidism is increased among symptomatic patients with mitral valve prolapse as compared to family members without mitral valve prolapse, but the prevalence of thyroid conditions is similar among family members with or without this condition. These findings are explained by the effect of common symptoms on clinical detection of both mitral valve prolapse and hyperthyroidism.

  4. A metal-organic framework based on nanosized hexagonal channels as fluorescent indicator for detection of nitroaromatic explosives

    Science.gov (United States)

    Hu, Xiao-Li; Wang, Xin-Long; Su, Zhong-Min

    2018-02-01

    A novel Zn-MOF (metal organic framework) [Zn3(NTB)2(DMA)2]·12DMA (NTB = 4,4‧,4″-nitrilotrisbenzoic acid; DMA = N,N-dimethylacetamide) (1) was obtained under solvothermal condition. The resulted MOF which is based on {Zn3} SBU displays an interesting (3,6)-connected three-dimensional net with nanosized, hexagonal channels. Additionally, 1 can be a useful fluorescent indicator for the detection of nitroaromatic explosives qualitatively and quantitatively via a strong quenching effect, especially for picric acid (PA). With increasing - NO2 groups, energy transfer from the electron-donating framework to high electron deficiency becomes more, making the effect of fluorescence quenching more obvious. The result demonstrates that the photo-induced electron transfer (PET) is responsible for the emission quenching.

  5. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    International Nuclear Information System (INIS)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Bosse, Harald; Tan, Jiubin

    2015-01-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10 −7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications. (paper)

  6. Absolute distance measurement by dual-comb interferometry with multi-channel digital lock-in phase detection

    Science.gov (United States)

    Yang, Ruitao; Pollinger, Florian; Meiners-Hagen, Karl; Krystek, Michael; Tan, Jiubin; Bosse, Harald

    2015-08-01

    We present a dual-comb-based heterodyne multi-wavelength absolute interferometer capable of long distance measurements. The phase information of the various comb modes is extracted in parallel by a multi-channel digital lock-in phase detection scheme. Several synthetic wavelengths of the same order are constructed and the corresponding phases are averaged to deduce the absolute lengths with significantly reduced uncertainty. Comparison experiments with an incremental HeNe reference interferometer show a combined relative measurement uncertainty of 5.3 × 10-7 at a measurement distance of 20 m. Combining the advantage of synthetic wavelength interferometry and dual-comb interferometry, our compact and simple approach provides sufficient precision for many industrial applications.

  7. Performance analysis of cognitive multihop relaying with m-QAM detect-and-forward in Nakagami-m fading channels

    KAUST Repository

    Benjillali, Mustapha; Hyadi, Amal; Da Costa, Daniel Benevides Da; Alouini, Mohamed-Slim

    2013-01-01

    In this work, we investigate the performance of cognitive multihop regenerative relaying systems in the "underlay" spectrum sharing scenario. The multiple relays perform "detect-and-forward" relaying strategy to convey a message with an order m quadrature amplitude modulation (m-QAM) from the source to the destination over independent but not necessarily identical Nakagami-m fading channels. We adopt a closed-form analysis framework based on univariate and bivariate Meijer G-functions to derive the end-to-end error performance (in terms of bit and symbol error rates), the outage probability, and the ergodic capacity. Various numerical examples are presented to illustrate the results with a large combination of system and fading parameters, and simulation results confirm the accuracy of our closed-form analysis. © 2013 IEEE.

  8. Performance analysis of cognitive multihop relaying with m-QAM detect-and-forward in Nakagami-m fading channels

    KAUST Repository

    Benjillali, Mustapha

    2013-09-01

    In this work, we investigate the performance of cognitive multihop regenerative relaying systems in the "underlay" spectrum sharing scenario. The multiple relays perform "detect-and-forward" relaying strategy to convey a message with an order m quadrature amplitude modulation (m-QAM) from the source to the destination over independent but not necessarily identical Nakagami-m fading channels. We adopt a closed-form analysis framework based on univariate and bivariate Meijer G-functions to derive the end-to-end error performance (in terms of bit and symbol error rates), the outage probability, and the ergodic capacity. Various numerical examples are presented to illustrate the results with a large combination of system and fading parameters, and simulation results confirm the accuracy of our closed-form analysis. © 2013 IEEE.

  9. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  10. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  11. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  12. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1990-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focused on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two noval nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  13. Recent improvements in check valve monitoring methods

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, ORNL has carried out an evaluation of three check valve monitoring methods: acoustic emission, ultrasonic inspection, and magnetic flux signature analysis (MFSA). This work has focussed on determining the capabilities of each method to provide diagnostic information useful in determining check valve aging and service wear effects (degradation) and undesirable operating modes. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed (external ac- and dc-magnetic monitoring) that provide several improvements over the other methods. None of the examined methods could, by themselves, monitor the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data to illustrate the capabilities of these methods to detect simulated check valve degradation. 3 refs., 22 figs., 4 tabs

  14. Early prosthetic valve endocarditis caused by Corynebacterium kroppenstedtii.

    Science.gov (United States)

    Hagemann, Jürgen Benjamin; Essig, Andreas; Herrmann, Manuel; Liebold, Andreas; Quader, Mohamed Abo

    2015-12-01

    Corynebacterium (C.) kroppenstedtii is a rarely detected agent of bacterial infections in humans. Here, we describe the first case of prosthetic valve endocarditis caused by C. kroppenstedtii. Application of molecular methods using surgically excised valve tissue was a cornerstone for the establishment of the microbiological diagnosis, which is crucial for targeted antimicrobial treatment. Copyright © 2015 Elsevier GmbH. All rights reserved.

  15. Detection of beamsplitting attack in a quantum cryptographic channel based on photon number statistics monitoring

    International Nuclear Information System (INIS)

    Gaidash, A A; Egorov, V I; Gleim, A V

    2014-01-01

    Quantum cryptography in theory allows distributing secure keys between two users so that any performed eavesdropping attempt would be immediately discovered. However, in practice an eavesdropper can obtain key information from multi-photon states when attenuated laser radiation is used as a source. In order to overcome this possibility, it is generally suggested to implement special cryptographic protocols, like decoy states or SARG04. We present an alternative method based on monitoring photon number statistics after detection. This method can therefore be used with any existing protocol

  16. An Embedded, Eight Channel, Noise Canceling, Wireless, Wearable sEMG Data Acquisition System With Adaptive Muscle Contraction Detection.

    Science.gov (United States)

    Ergeneci, Mert; Gokcesu, Kaan; Ertan, Erhan; Kosmas, Panagiotis

    2018-02-01

    Wearable technology has gained increasing popularity in the applications of healthcare, sports science, and biomedical engineering in recent years. Because of its convenient nature, the wearable technology is particularly useful in the acquisition of the physiological signals. Specifically, the (surface electromyography) sEMG systems, which measure the muscle activation potentials, greatly benefit from this technology in both clinical and industrial applications. However, the current wearable sEMG systems have several drawbacks including inefficient noise cancellation, insufficient measurement quality, and difficult integration to customized applications. Additionally, none of these sEMG data acquisition systems can detect sEMG signals (i.e., contractions), which provides a valuable environment for further studies such as human machine interaction, gesture recognition, and fatigue tracking. To this end, we introduce an embedded, eight channel, noise canceling, wireless, wearable sEMG data acquisition system with adaptive muscle contraction detection. Our design consists of two stages, which are the sEMG sensors and the multichannel data acquisition unit. For the first stage, we propose a low cost, dry, and active sEMG sensor that captures the muscle activation potentials, a data acquisition unit that evaluates these captured multichannel sEMG signals and transmits them to a user interface. In the data acquisition unit, the sEMG signals are processed through embedded, adaptive methods in order to reject the power line noise and detect the muscle contractions. Through extensive experiments, we demonstrate that our sEMG sensor outperforms a widely used commercially available product and our data acquisition system achieves 4.583 dB SNR gain with accuracy in the detection of the contractions.

  17. Inspection systems for valves monitoring at EDF

    International Nuclear Information System (INIS)

    Germain, J.L.; Granal, L.; Provost, D.; Touillez, M.

    1997-01-01

    Electricite de France (EDF) makes increasing use of valve inspection systems to guarantee safety in its pressurized water reactor plants, improve plant availability and facilitate condition-based maintenance. A portable system known as SAMIR has been developed for inspection of motor-operated valves, and is now used on EDF's 900-MW sites. For its 1300-MW units, EDF has chosen a more complete system which enables measuring thrust on the valve stem during a maneuver, using a sensor mounted on the yoke. To detect internal vale leaks, an on-site assessment has demonstrated the economic benefits of acoustic emission techniques. EDF has equipped its sites with analog leak detection systems which may soon be replaced by a digital model now being developed. (authors)

  18. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  19. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  20. In-Channel-Grown Polypyrrole Nanowire for the Detection of DNA Hybridization in an Electrochemical Microfluidic Biosensor

    Directory of Open Access Journals (Sweden)

    Thi Luyen Tran

    2015-01-01

    Full Text Available A triple electrode setup with a Pt pseudo-reference electrode integrated in a polydimethylsiloxane- (PDMS- based microchamber was designed and fabricated. The integrated electrodes were deposited onto SiO2/Si substrate by sputtering. The PDMS microchamber was patterned using an SU-8 mold and sealed with electrodes in oxygen plasma. Polypyrrole nanowires (PPy NWs were electrochemically grown in situ at an accurate position of the working electrode in the sealed microchamber instead of in an open system. The DNA probe sequences were simply introduced into the channel to form bonds with the nanowires. A detection limit of 20 pM was achieved using a lock-in amplifier. The electrochemical characteristics produced by the hybridization of DNA strands in the microchamber showed a good signal/noise ratio and high sensitivity. Measurement of the DNA sensor in narrow space also required much less volume of the analytical sample compared with that in an open measuring cell. Results showed that this simple system can potentially fabricate nanostructures and detect bio/chemical molecules in a sealed system.

  1. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  2. Study and optimization of the ionisation channel in the Edelweiss dark matter direct detection experiment

    International Nuclear Information System (INIS)

    Censier, B.

    2006-02-01

    The EDELWEISS experiment is aiming at the detection of Weakly Interactive Massive Particles (WIMPs), today's most favoured candidates for solving the dark matter issue. Background ionising particles are identified thanks to the simultaneous measurement of heat and ionisation in the detectors. The main limitation to this method is coming from the ionisation measurement, charge collection being less efficient in some part of the detectors known as 'dead' areas. The specificity of the measurement is due to the use of very low temperatures and low collection fields. This thesis is dedicated to the study of carrier trapping. It involves time-resolved charge measurements as well as a simulation code adapted to the specific physical conditions. We first present results concerning charge trapping at the free surfaces of the detectors. Our method allows to build a surface-charge in a controlled manner by irradiation with a strong radioactive source. This charge is then characterised with a weaker source which acts as a probe. In a second part of the work, bulk-trapping characteristics are deduced from charge collection efficiency measurements, and by an original method based on event localisation in the detector. The results show that a large proportion of the doping impurities are ionised, as indicated independently by the study of degradation by space-charge build-up. In this last part, near-electrodes areas are found to contain large densities of charged trapping centres, in connection with dead-layer effects. (author)

  3. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  4. Detection of paleochannels using hydrogeophysical methods: An approach for more effective channel restoration

    Science.gov (United States)

    Altdorff, D.; Dietrich, P.; Epting, J.; Huggenberger, P.

    2011-12-01

    River restoration and applied restoration measures are of increasing importance for integrated water resources management (IWRM) as well as for ecosystem services including water storage and purification, habitat provision and climate regulation. However, often river restoration is planned and realized by engineering and constructing aspects only and hydrogeological settings and ancient stream dynamics are neglected. As a result desired outcomes of restoration projects are reduced with no significant alteration of stream conditions by simultaneously increasing costs. An opportunity to max out the restoration potential is to investigate ancient stream courses by applying hydrogeophysical methods as basis for targeted restoration measures. In this study, we investigate the paleochannel courses in a floodplain of a heavy modified low-mountain river in Switzerland by different hydrogeophysical methods. We use data from electromagnetic induction (EMI) with four different integral depths (0.75 to 6m) and gamma-spectrometry (GS) to generate a geological structure model (GSM) that allows delineating potential ancient stream courses. Thereby we derive the GSM iteratively by means of various electric conductivity (EC) forward models. We vary the geological input parameters based on the measured data until the synthetic EC maps fit to the real EC values. Then we incorporate the best fitted input data for a final GSM that shows the course of an ancient stream between the 2nd and 3rd layer (Fig 1). A comparison with a historical map shows good agreement with the situation before the river modification and also profiles from Ground Penetrating Radar (GPR) could generally confirm the obtained progression of ancient riverbed structures. The demonstrated iterative method is a tool for the characterization of test sites with no subsurface information and with the potential of detecting paleochannels.

  5. Ion-channel genosensor for the detection of specific DNA sequences derived from Plum Pox Virus in plant extracts.

    Science.gov (United States)

    Malecka, Kamila; Michalczuk, Lech; Radecka, Hanna; Radecki, Jerzy

    2014-10-09

    A DNA biosensor for detection of specific oligonucleotides sequences of Plum Pox Virus (PPV) in plant extracts and buffer is proposed. The working principles of a genosensor are based on the ion-channel mechanism. The NH2-ssDNA probe was deposited onto a glassy carbon electrode surface to form an amide bond between the carboxyl group of oxidized electrode surface and amino group from ssDNA probe. The analytical signals generated as a result of hybridization were registered in Osteryoung square wave voltammetry in the presence of [Fe(CN)6]3-/4- as a redox marker. The 22-mer and 42-mer complementary ssDNA sequences derived from PPV and DNA samples from plants infected with PPV were used as targets. Similar detection limits of 2.4 pM (31.0 pg/mL) and 2.3 pM (29.5 pg/mL) in the concentration range 1-8 pM were observed in the presence of the 22-mer ssDNA and 42-mer complementary ssDNA sequences of PPV, respectively. The genosensor was capable of discriminating between samples consisting of extracts from healthy plants and leaf extracts from infected plants in the concentration range 10-50 pg/mL. The detection limit was 12.8 pg/mL. The genosensor displayed good selectivity and sensitivity. The 20-mer partially complementary DNA sequences with four complementary bases and DNA samples from healthy plants used as negative controls generated low signal.

  6. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  7. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  8. Pulmonary valve stenosis

    Science.gov (United States)

    ... surgery - discharge Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  9. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  10. Aortic Valve Disease

    Science.gov (United States)

    ... team will discuss with you the advantages and disadvantages of both valve types. Regardless of which type ... Diagnosis and Treatment Options Recovery Questions for Your Doctor Will my condition ever get better without treatment? ...

  11. Dry product valve

    International Nuclear Information System (INIS)

    Greaves, James D.

    1984-01-01

    This invention provides a system for delivering particulate radioactive or other toxic wastes to a container in which they can be solidified. The system includes a set of valves that prevent the escape of dusty materials to the atmosphere

  12. Valve for gas centrifuges

    Science.gov (United States)

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  13. Coanda effect in valves

    Directory of Open Access Journals (Sweden)

    Uruba Václav

    2017-01-01

    Full Text Available Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.

  14. Separation followed by direct SERS detection of explosives on a novel black silicon multifunctional nanostructured surface prepared in a microfluidic channel

    DEFF Research Database (Denmark)

    Talian, Ivan; Hübner, Jörg

    2013-01-01

    The article describes the multifunctionality of a novel black silicon (BS) nanostructured surface covered with a thin layer of noble metal prepared in the a microfluidic channel. It is focused on the separation properties of the BS substrate with direct detection of the separated analytes utilizing...

  15. Automated electric valve for electrokinetic separation in a networked microfluidic chip.

    Science.gov (United States)

    Cui, Huanchun; Huang, Zheng; Dutta, Prashanta; Ivory, Cornelius F

    2007-02-15

    This paper describes an automated electric valve system designed to reduce dispersion and sample loss into a side channel when an electrokinetically mobilized concentration zone passes a T-junction in a networked microfluidic chip. One way to reduce dispersion is to control current streamlines since charged species are driven along them in the absence of electroosmotic flow. Computer simulations demonstrate that dispersion and sample loss can be reduced by applying a constant additional electric field in the side channel to straighten current streamlines in linear electrokinetic flow (zone electrophoresis). This additional electric field was provided by a pair of platinum microelectrodes integrated into the chip in the vicinity of the T-junction. Both simulations and experiments of this electric valve with constant valve voltages were shown to provide unsatisfactory valve performance during nonlinear electrophoresis (isotachophoresis). On the basis of these results, however, an automated electric valve system was developed with improved valve performance. Experiments conducted with this system showed decreased dispersion and increased reproducibility as protein zones isotachophoretically passed the T-junction. Simulations of the automated electric valve offer further support that the desired shape of current streamlines was maintained at the T-junction during isotachophoresis. Valve performance was evaluated at different valve currents based on statistical variance due to dispersion. With the automated control system, two integrated microelectrodes provide an effective way to manipulate current streamlines, thus acting as an electric valve for charged species in electrokinetic separations.

  16. Detection of a regulating valve closure failure during review of recorded data after an automatic reactor shut down. Incident at the NPP Beznau-1, 27 April 1995

    International Nuclear Information System (INIS)

    Deutschmann, H.

    1996-01-01

    After recognizing a leak in the oil system of the running main feedwater pump 1 during rated power operation of the plant the operator changed feedwater supply manually to the stand-by pump 2. A short time later pump 2 was automatically tripped by the signal ''low oil pressure''. Immediate reduction of the reactor power by the operator was not successful because the scram signal ''low steam generator level and mismatch of steam/feedwater flow'' occurred and scram was actuated. In this plant a special operating feature, actuated by the scram signal, is implemented to reduce steam release to atmosphere in case of scram. The signal ''scram and average primary Temperature >287 deg. C opens the feedwater regulating valves, and later, if the average primary temperature decreases to <287 deg. C, they reclose by a redundant signal. In the experienced event, after the scram actuation, in the steam generator A a feedwater overfill occurred. The overfill protection tripped the operating feedwater pumps (main feedwater pump 3 and two auxiliary feedwater pumps). The large injection of water produced an overcooling of the primary with isolation of the volume control system outlet of the primary. The operator repaired the defective oil coolers of the feedwater pumps and restarted the plant. At that time, he had not recognized, that the plant response, which caused the steam generator overfill, was wrong. One day later, as all the recorded data were reviewed in more detail, it was found that the closure time of the feedwater regulating valve to steam generator A was much longer than designed (19 s instead 7 s). The operator requested an LCO for continued operation in spite of the fact, that the closure time was not fixed in the Technical specification. 3 figs

  17. Evaluation of a novel PTFE material for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems interfaced with detection by ETAAS

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Gała, Piotr

    The operational characteristics of a novel PTFE bead material, granular Algoflon®, used for separation and preconcentration of metal ions via adsorption of on-line generated non-charged metal complexes, were evaluated in a sequential injection (SI) system furnished with an external packed column...... and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used material, Aldrich PTFE, which had...... demonstrated that PTFE was the most promising for solid-state pretreatments. By comparing the two materials, the Algoflon® beads exhibited much higher sensitivity (1.6107 versus 0.2956 μg l-1 per integrated absorbance (s)), and better retention efficiency (82% versus 74%) and enrichment factor (20.8 versus 17...

  18. Space Shuttle Program (SSP) Orbiter Main Propulsion System (MPS) Gaseous Hydrogen (GH2) Flow Control Valve (FCV) Poppet Eddy Current (EC) Inspection Probability of Detection (POD) Study. Volume 1

    Science.gov (United States)

    Piascik, Robert S.; Prosser, William H.

    2011-01-01

    The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the findings and recommendations from the NESC assessment.

  19. Space Shuttle Program (SSP) Orbiter Main Propulsion System (MPS) Gaseous Hydrogen (GH2) Flow Control Valve (FCV) Poppet Eddy Current (EC) Inspection Probability of Detection (POD) Study. Volume 2; Appendices

    Science.gov (United States)

    Piascik, Robert S.; Prosser, William H.

    2011-01-01

    The Director of the NASA Engineering and Safety Center (NESC), requested an independent assessment of the anomalous gaseous hydrogen (GH2) flow incident on the Space Shuttle Program (SSP) Orbiter Vehicle (OV)-105 during the Space Transportation System (STS)-126 mission. The main propulsion system (MPS) engine #2 GH2 flow control valve (FCV) LV-57 transition from low towards high flow position without being commanded. Post-flight examination revealed that the FCV LV-57 poppet had experienced a fatigue failure that liberated a section of the poppet flange. The NESC assessment provided a peer review of the computational fluid dynamics (CFD), stress analysis, and impact testing. A probability of detection (POD) study was requested by the SSP Orbiter Project for the eddy current (EC) nondestructive evaluation (NDE) techniques that were developed to inspect the flight FCV poppets. This report contains the Appendices to the main report.

  20. Rapid multiplex detection of 10 foodborne pathogens with an up-converting phosphor technology-based 10-channel lateral flow assay

    Science.gov (United States)

    Zhao, Yong; Wang, Haoran; Zhang, Pingping; Sun, Chongyun; Wang, Xiaochen; Wang, Xinrui; Yang, Ruifu; Wang, Chengbin; Zhou, Lei

    2016-01-01

    The rapid high-throughput detection of foodborne pathogens is essential in controlling food safety. In this study, a 10-channel up-converting phosphor technology-based lateral flow (TC-UPT-LF) assay was established for the rapid and simultaneous detection of 10 epidemic foodborne pathogens. Ten different single-target UPT-LF strips were developed and integrated into one TC-UPT-LF disc with optimization. Without enrichment the TC-UPT-LF assay had a detection sensitivity of 104 CFU mL−1 or 105 CFU mL−1 for each pathogen, and after sample enrichment it was 10 CFU/0.6 mg. The assay also showed good linearity, allowing quantitative detection, with a linear fitting coefficient of determination (R2) of 0.916–0.998. The 10 detection channels did not cross-react, so multiple targets could be specifically detected. When 279 real food samples were tested, the assay was highly consistent (100%) with culture-based methods. The results for 110 food samples artificially contaminated with single or multiple targets showed a high detection rate (≥80%) for most target bacteria. Overall, the TC-UPT-LF assay allows the rapid, quantitative, and simultaneous detection of 10 kinds of foodborne pathogens within 20 min, and is especially suitable for the rapid detection and surveillance of foodborne pathogens in food and water. PMID:26884128

  1. Efficient and Robust Detection of GFSK Signals under Dispersive Channel, Modulation Index, and Carrier Frequency Offset Conditions

    Directory of Open Access Journals (Sweden)

    Stephan Weiss

    2005-09-01

    Full Text Available Gaussian frequency shift keying is the modulation scheme specified for Bluetooth. Signal adversities typical in Bluetooth networks include AWGN, multipath propagation, carrier frequency, and modulation index offsets. In our effort to realise a robust but efficient Bluetooth receiver, we adopt a high-performance matched-filter-based detector, which is near optimal in AWGN, but requires a prohibitively costly filter bank for processing of K bits worth of the received signal. However, through filtering over a single bit period and performing phase propagation of intermediate results over successive single-bit stages, we eliminate redundancy involved in providing the matched filter outputs and reduce its complexity by up to 90% (for K=9. The constant modulus signal characteristic and the potential for carrier frequency offsets make the constant modulus algorithm (CMA suitable for channel equalisation, and we demonstrate its effectiveness in this paper. We also introduce a stochastic gradient-based algorithm for carrier frequency offset correction, and show that the relative rotation between successive intermediate filter outputs enables us to detect and correct offsets in modulation index.

  2. A laser microsurgical method of cell wall removal allows detection of large-conductance ion channels in the guard cell plasma membrane

    Science.gov (United States)

    Miedema, H.; Henriksen, G. H.; Assmann, S. M.; Evans, M. L. (Principal Investigator)

    1999-01-01

    Application of patch clamp techniques to higher-plant cells has been subject to the limitation that the requisite contact of the patch electrode with the cell membrane necessitates prior enzymatic removal of the plant cell wall. Because the wall is an integral component of plant cells, and because cell-wall-degrading enzymes can disrupt membrane properties, such enzymatic treatments may alter ion channel behavior. We compared ion channel activity in enzymatically isolated protoplasts of Vicia faba guard cells with that found in membranes exposed by a laser microsurgical technique in which only a tiny portion of the cell wall is removed while the rest of the cell remains intact within its tissue environment. "Laser-assisted" patch clamping reveals a new category of high-conductance (130 to 361 pS) ion channels not previously reported in patch clamp studies on plant plasma membranes. These data indicate that ion channels are present in plant membranes that are not detected by conventional patch clamp techniques involving the production of individual plant protoplasts isolated from their tissue environment by enzymatic digestion of the cell wall. Given the large conductances of the channels revealed by laser-assisted patch clamping, we hypothesize that these channels play a significant role in the regulation of ion content and electrical signalling in guard cells.

  3. Cell pairing ratio controlled micro-environment with valve-less electrolytic isolation

    KAUST Repository

    Chen, Yu-Chih; Lou, Xia; Ingram, Patrick; Yoon, Euisik

    2012-01-01

    We present a ratio controlled cell-to-cell interaction chip using valve-less isolation. We incorporated electrolysis in a microfluidic channel. In each microfluidic chamber, we loaded two types of different cells at various pairing ratios. More than

  4. Evaluation of a novel PTFE material for use as a means for separation and preconcentration of trace levels of metal ions in sequential injection (SI) and sequential injection lab-on-valve (SI-LOV) systems. Determination of cadmium (II) with detection by electrothermal atomic absorption spectrometry

    DEFF Research Database (Denmark)

    Long, Xiangbao; Chomchoei, Roongrat; Hansen, Elo Harald

    2004-01-01

    with an external packed column and in a sequential injection lab-on-valve (SI-LOV) system. Employed for the determination of cadmium(II), complexed with diethyldithiophosphate (DDPA), and detection by electrothermal atomic absorption spectrometry (ETAAS), its performance was compared to that of a previously used...

  5. Complementary role of cardiac CT in the assessment of aortic valve replacement dysfunction

    Science.gov (United States)

    Moss, Alastair J; Dweck, Marc R; Dreisbach, John G; Williams, Michelle C; Mak, Sze Mun; Cartlidge, Timothy; Nicol, Edward D; Morgan-Hughes, Gareth J

    2016-01-01

    Aortic valve replacement is the second most common cardiothoracic procedure in the UK. With an ageing population, there are an increasing number of patients with prosthetic valves that require follow-up. Imaging of prosthetic valves is challenging with conventional echocardiographic techniques making early detection of valve dysfunction or complications difficult. CT has recently emerged as a complementary approach offering excellent spatial resolution and the ability to identify a range of aortic valve replacement complications including structural valve dysfunction, thrombus development, pannus formation and prosthetic valve infective endocarditis. This review discusses each and how CT might be incorporated into a multimodal cardiovascular imaging pathway for the assessment of aortic valve replacements and in guiding clinical management. PMID:27843568

  6. Ureteral valve masquerading as obstructive megaureter

    Directory of Open Access Journals (Sweden)

    Sushmita Bhatnagar

    2017-05-01

    Full Text Available Primary obstructed megaureter is a common urological condition in the pediatric age group. It is one of the differentials for congenital anomalies of the kidney and urinary tract that include a myriad of structural anomalies of the urinary tract. The obstructive conditions are usually managed conservatively unless there is deterioration in renal function, repeated urinary tract infection, or any other symptom such as abdominal pain on ipsilateral side and hypertension. Presented here is a case of left lower ureteral valve that was diagnosed as primary obstructed megaureter with pain in abdomen and reduced ipsilateral renal function wherein ureteral valve was detected incidentally intraoperatively. Excision of the valve with end to end uretero-ureteral anastomoses over a D-J stent, without resorting to ureteric reimplantation was successful in relieving the obstruction and hydronephrosis

  7. Lymphangiogenesis is increased in heart valve endocarditis.

    Science.gov (United States)

    Niinimäki, Eetu; Mennander, Ari A; Paavonen, Timo; Kholová, Ivana

    2016-09-15

    Inflammation-associated lymphangiogenesis (IAL) has been identified as part of several acute and chronic inflammation. Sparse data exist on lymphatics during endocarditis. Fifty-two patients with surgically resected valves were included. Endocarditis was present in 18 aortic and 10 mitral valves. Controls consisted of 15 degenerative aortic and 9 degenerative mitral valves. There were 22 males with endocarditis and 17 males in controls. The mean age was 58 (SD 15) years with endocarditis vs. 62 (SD 13) years for controls. Lymphatics were detected by podoplanin antibody immunohistochemistry and morphometrical analysis was performed. The lymphatic density in endocarditis was 833 (SD 529) vessels/mm(2) (range 0-1707) as compared with 39 (SD 60) vessels/mm(2) (range 0-250) in controls (p=0.000). In endocarditis, the mean lymphatic size was 153 (SD 372) μm(2) ranging from 1 to 2034μm(2), whereas it was 30 (SD 29) μm(2), with maximum 90μm(2) and minimum 2μm(2) in controls (p=0.000). IAL is increased in valves with endocarditis as compared with controls. Lymphatics in heart valves may provide a novel means for treatment strategies against endocarditis. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  8. Characterizations of gas purge valves for liquid alignment and gas removal in a microfluidic chip

    International Nuclear Information System (INIS)

    Chuang, Han-Sheng; Thakur, Raviraj; Wereley, Steven T

    2012-01-01

    Two polydimethylsiloxane (PDMS) gas purge valves for excessive gas removal in general lab-on-a-chip applications are presented in this paper. Both valves are devised based on a three-layer configuration comprising a top layer for liquid channels, a membrane and a bottom layer for gas channels. The pneumatic valves work as a normal gateway for fluids when the membrane is bulged down (open state) by vacuum or pushed up (closed state) by pressure. In the closed state, the air in front of a liquid can be removed through a small notch or a permeable PDMS membrane by compressing the liquid. The purge valve with a small notch across its valve seat, termed surface-tension (ST) valve, can be operated with pressure under 11.5 kPa. The liquid is mainly retained by the surface tension resulting from the hydrophobic channel walls. In contrast, the purge valve with vacuum-filled grooves adjacent to a liquid channel, termed gas-permeation (GP) valve, can be operated at pressure above 5.5 kPa. Based on the principle of gas permeation, the excessive air can be slowly removed through the vent grooves. Detailed evaluations of both valves in a pneumatically driven microfluidic chip were conducted. Specifically, the purge valves enable users to remove gas and passively align liquids at desired locations without using sensing devices or feedback circuits. Finally, a rapid mixing reaction was successfully performed with the GP valves, showing their practicability as incorporated in a microfluidic chip. (paper)

  9. Magnetostatic Analysis of a Pinch Mode Magnetorheological Valve

    Directory of Open Access Journals (Sweden)

    Gołdasz Janusz

    2017-09-01

    Full Text Available The study deals with the pinch mode of magnetorheological (MR fluids’ operation and its application in MR valves. By applying the principle in MR valves a highly non-uniform magnetic field can be generated in flow channels in such a way to solidify the portion of the material that is the nearest to the flow channel’s walls. This is in contrary to well-known MR flow mode valves. The authors investigate a basic pinch mode valve in several fundamental configurations, and then examine their magnetic circuits through magnetostatic finite-element (FE analysis. Flux density contour maps are revealed and basic performance figures calculated and analysed. The FE analysis results yield confidence in that the performance of MR pinch mode devices can be effectively controlled through electromagnetic means.

  10. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  11. Regulation of the epithelial Ca2+ channels in small intestine as studied by quantitative mRNA detection.

    NARCIS (Netherlands)

    Abel, M. van; Hoenderop, J.G.J.; Kemp, J.W.C.M. van der; Leeuwen, J.P.P.M. van; Bindels, R.J.M.

    2003-01-01

    The epithelial Ca2+ channels TRPV5 and TRPV6 are localized to the brush border membrane of intestinal cells and constitute the postulated rate-limiting entry step of active Ca2+ absorption. The aim of the present study was to investigate the hormonal regulation of these channels. To this end, the

  12. Features of mitral valve prolapse in young patients

    Directory of Open Access Journals (Sweden)

    M. A. Kuznetsova

    2015-06-01

    Full Text Available Due to the significant increase of complications in young patients with mitral valve prolapse detection of this disease is important. Aim. With the aim of studying the features of mitral valve prolapse 135 persons with mitral valve prolapse at the age of 18–25 years were examined. Methods and results. The features of mitral valve prolapsed were studied with echocardiography, electrocardiography, cardiointervalography. It was established that mitral valve prolapse (MVP in young age had different clinical picture. Patients with MVP 1 degree mainly had autonomic instability, and with 2 degree - mostly signs of connective tissue dysplasia. Conclusion. The presence of MVP is associated with abnormalities of the rhythm and conductivity: 1 degree - sinus tachycardia; the 2nd - sinus arrhythmia, signs of left ventricular hypertrophy and impaired repolarization of the myocardium.

  13. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  14. Controllable picoliter pipetting using hydrophobic microfluidic valves

    Science.gov (United States)

    Zhang, M.; Huang, J.; Qian, X.; Mi, S.; Wang, X.

    2017-06-01

    A picoliter pipetting technique using the microfluidic method is presented. Utilizing the hydrophobic self-assembled monolayer films patterned in microchannels as pressure-controlled valves, a small volume of liquid can be separated by a designed channel trap and then ejected from the channel end at a higher pressure. The liquid trap section is composed of a T-shaped channel junction and a hydrophobic patch. The liquid volume can be precisely controlled by varying the distance of the hydrophobic patch from the T-junction. By this means, liquid less than 100 pl can be separated and pipetted. The developed device is potentially useful for sample dispensing in biological, medical, and chemical applications.

  15. An application of the valve-leak monitoring system to the valves for the improved Korean standard nuclear power plant (KSNP+)

    International Nuclear Information System (INIS)

    Byeong-yeol AHN; Dae-sik CHOI; Sang-kook CHUNG

    2006-01-01

    The loss of steam due to valve leakage leads to the inefficiency of power generation at the nuclear power plants. Under the normal conditions of plant operation, it is difficult to detect valve leaks early enough to prevent consequential damages and losses. The capability of timely detection allows the plant adequate time to prepare repair plans, which would ultimately result in efficient power production. Therefore, timing of detection is one of the most important factors in dealing with valve leakage problems. The VLMS has been developed to meet such an industrial demand. It provides early detection of valve leakage by real-time monitoring through the acoustic sensors installed on the inlet and the outlet of the valve. The KSNP+ utilizes the VLMS to enhance the performance and maintenance of major valves at plants. The VLMS will enable the plant to detect the leakage of valve at an early stage. It can reduce the steam losses and save related valve maintenance cost by performing fast diagnosis of valve leakage. (authors)

  16. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  17. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  18. A symmetric safety valve

    International Nuclear Information System (INIS)

    Burtraw, Dallas; Palmer, Karen; Kahn, Danny

    2010-01-01

    How to set policy in the presence of uncertainty has been central in debates over climate policy. Concern about costs has motivated the proposal for a cap-and-trade program for carbon dioxide, with a 'safety valve' that would mitigate against spikes in the cost of emission reductions by introducing additional emission allowances into the market when marginal costs rise above the specified allowance price level. We find two significant problems, both stemming from the asymmetry of an instrument that mitigates only against a price increase. One is that most important examples of price volatility in cap-and-trade programs have occurred not when prices spiked, but instead when allowance prices collapsed. Second, a single-sided safety valve may have unintended consequences for investment. We illustrate that a symmetric safety valve provides environmental and welfare improvements relative to the conventional one-sided approach.

  19. Check valve diagnostics utilizing acoustic and magnetic technologies

    International Nuclear Information System (INIS)

    Agostinelli, A.

    1991-01-01

    The potential hazards associated with check valve failures make it necessary to detect check valve problems before they cause significant damage. In the nuclear industry, check valve failures are known to have resulted in damaging water hammer conditions, overpressurization of low pressure systems, steam binding of auxiliary feedwater pumps, and other serious component damage in power plant environments. Similar problems exist in fossil power and various process industries, but the resources dedicated to valve maintenance issues are greatly reduced. However, the trend toward plant life extension, predictive maintenance, and maximum operating efficiency will raise the general awareness of check valve maintenance in commercial (non-nuclear) applications. Although this paper includes specific references to the nuclear industry, the check valve problem conditions and diagnostic techniques apply across all power and process plant environments. The ability to accurately diagnose check valve conditions using non-intrusive, predictive maintenance testing methods allows for a more cost-efficient, productive maintenance program. One particular diagnostic system, called Quickcheck trademark, assists utilities in addressing these concerns. This article presents actual field test data and analysis that demonstrate the power of check valve diagnostics. Prior to presenting the field data, a brief overview of the system is overviewed

  20. Spin valve sensor for biomolecular identification: Design, fabrication, and characterization

    Science.gov (United States)

    Li, Guanxiong

    Biomolecular identification, e.g., DNA recognition, has broad applications in biology and medicine such as gene expression analysis, disease diagnosis, and DNA fingerprinting. Therefore, we have been developing a magnetic biodetection technology based on giant magnetoresistive spin valve sensors and magnetic nanoparticle (developed for the magnetic nanoparticle detection, assuming the equivalent average field of magnetic nanoparticles and the coherent rotation of spin valve free layer magnetization. Micromagnetic simulations have also been performed for the spin valve sensors. The analytical model and micromagnetic simulations are found consistent with each other and are in good agreement with experiments. The prototype spin valve sensors have been fabricated at both micron and submicron scales. We demonstrated the detection of a single 2.8-mum magnetic microbead by micron-sized spin valve sensors. Based on polymer-mediated self-assembly and fine lithography, a bilayer lift-off process was developed to deposit magnetic nanoparticles onto the sensor surface in a controlled manner. With the lift-off deposition method, we have successfully demonstrated the room temperature detection of monodisperse 16-nm Fe3O 4 nanoparticles in a quantity from a few tens to several hundreds by submicron spin valve sensors, proving the feasibility of the nanoparticle detection. As desired for quantitative biodetection, a fairly linear dependence of sensor signal on the number of nanoparticles has been confirmed. The initial detection of DNA hybridization events labeled by magnetic nanoparticles further proved the magnetic biodetection concept.

  1. Combining a wavelet transform with a channelized Hotelling observer for tumor detection in 3D PET oncology imaging

    Science.gov (United States)

    Lartizien, Carole; Tomei, Sandrine; Maxim, Voichita; Odet, Christophe

    2007-03-01

    This study evaluates new observer models for 3D whole-body Positron Emission Tomography (PET) imaging based on a wavelet sub-band decomposition and compares them with the classical constant-Q CHO model. Our final goal is to develop an original method that performs guided detection of abnormal activity foci in PET oncology imaging based on these new observer models. This computer-aided diagnostic method would highly benefit to clinicians for diagnostic purpose and to biologists for massive screening of rodents populations in molecular imaging. Method: We have previously shown good correlation of the channelized Hotelling observer (CHO) using a constant-Q model with human observer performance for 3D PET oncology imaging. We propose an alternate method based on combining a CHO observer with a wavelet sub-band decomposition of the image and we compare it to the standard CHO implementation. This method performs an undecimated transform using a biorthogonal B-spline 4/4 wavelet basis to extract the features set for input to the Hotelling observer. This work is based on simulated 3D PET images of an extended MCAT phantom with randomly located lesions. We compare three evaluation criteria: classification performance using the signal-to-noise ratio (SNR), computation efficiency and visual quality of the derived 3D maps of the decision variable λ. The SNR is estimated on a series of test images for a variable number of training images for both observers. Results: Results show that the maximum SNR is higher with the constant-Q CHO observer, especially for targets located in the liver, and that it is reached with a smaller number of training images. However, preliminary analysis indicates that the visual quality of the 3D maps of the decision variable λ is higher with the wavelet-based CHO and the computation time to derive a 3D λ-map is about 350 times shorter than for the standard CHO. This suggests that the wavelet-CHO observer is a good candidate for use in our guided

  2. Simultaneous estimation of vitamin K1 and heparin with low limit of detection using cascaded channels fiber optic surface plasmon resonance.

    Science.gov (United States)

    Tabassum, Rana; Gupta, Banshi D

    2016-12-15

    We report an approach for the simultaneous estimation of vitamin K1 (VK1) and heparin via cascaded channel multianalyte sensing probe employing fiber optic surface plasmon resonance technique. Cladding from two well separated portions of the fiber is removed and are respectively coated with thin films of silver (channel-1) and copper (channel-2). The nanohybrid of multiwalled carbon nanotube in chitosan is fabricated over silver layer for the sensing of VK1 whereas core shell nanostructure of polybrene@ZnO is coated over copper layer for the sensing of heparin. Spectral interrogation method is used for the characterization of the sensor. Analyte selectivity of both the channels is performed by carrying out experiments using independent solutions of VK1 and heparin. Experiments performed on the solution of the mixture of VK1 and heparin show red shifts in both the channels on changing the concentration of both the analytes in the mixture. The operating range of both VK1 and heparin is from 0 to 10(-3)g/l. The limit of detection of the sensor is 2.66×10(-4)µg/l and 2.88×10(-4)µg/l for VK1 and heparin respectively which are lower than the reported ones. The additional advantages of the present sensor are low cost, possibility of online monitoring and remote sensing. Copyright © 2016 Elsevier B.V. All rights reserved.

  3. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  4. Valve spindle gland

    International Nuclear Information System (INIS)

    Burda, Z.; Harazim, A.; Kerlin, K.

    1979-01-01

    A gland is proposed of the valve spindle designed for radioactive or otherwise harmful media, such as in nuclear power plant primary circuits. The gland is installed in the valve cover and consists of a primary and a secondary part and of a gland case partitioning the gland space into two chambers. The bottom face of the gland case is provided with a double-sided collar for controlling the elements of the bottom primary gland while the top face is provided with a removable flange. (M.S.)

  5. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  6. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  7. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  8. Predicting postnatal renal function of prenatally detected posterior urethral valves using fetal diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient determination.

    Science.gov (United States)

    Faure, Alice; Panait, Nicoleta; Panuel, Michel; Alessandrini, Pierre; D'Ercole, Claude; Chaumoitre, Kathia; Merrot, Thierry

    2017-07-01

    The objective of this study was to evaluate the accuracy of fetal diffusion-weighted magnetic resonance imaging with apparent diffusion coefficient (ADC) determination to predict postnatal renal function (nadir creatinine at 1 year and eGFR) of men with posterior urethral valves (PUV). Between 2003 and 2014, 11 MRI were performed on fetuses (between 28 and 32 weeks) in whom second trimester sonography suggested severe bilateral urinary tract anomalies, suspected of PUV. The ADC of the 11 fetuses ranged from 1.3 to 2.86 mm 2  s -1 (median = 1.79 mm 2  s -1 , normal range for fetal kidney: 1.1-1.8). Two pregnancies with ADC > 2.6 mm 2  s -1 were interrupted; the autopsy confirmed PUV and Potter syndrome. For the remaining nine babies, the follow-up was 5.4 years (0.8-10). Four children with abnormal ADC (1.8-2.3) had chronic kidney disease. The remaining five cases with normal nadir creatinine and eGFR had normal ADC. One case with unilateral elevated ADC had a poor ipsilateral renal function on dimercaptosuccinic acid scan. Here, it seems that diffusion-weighted magnetic resonance imaging with ADC determination could be useful in accurately evaluating fetal kidneys in PUV and predicting renal function. It may be an additional, non-invasive method when biologic and sonographic findings are inconclusive, especially in the case of oligohydramnios. Further studies are needed to confirm our data. © 2017 John Wiley & Sons, Ltd. © 2017 John Wiley & Sons, Ltd.

  9. Detecting the impact of bank and channel modification on invertebrate communities in Mediterranean temporary streams (Sardinia, SW Italy).

    Science.gov (United States)

    Buffagni, Andrea; Tenchini, Roberta; Cazzola, Marcello; Erba, Stefania; Balestrini, Raffaella; Belfiore, Carlo; Pagnotta, Romano

    2016-09-15

    We hypothesized that reach-scale, bank and channel modification would impact benthic communities in temporary rivers of Sardinia, when pollution and water abstraction are not relevant. A range of variables were considered, which include both artificial structures/alterations and natural features observed in a stream reach. Multivariate regression trees (MRT) were used to assess the effects of the explanatory variables on invertebrate assemblages and five groups, characterized by different habitat modification and/or features, were recognized. Four node variables determined the splits in the MRT analysis: channel reinforcement, tree-related bank and channel habitats, channel modification and bank modification. Continuity of trees in the river corridor diverged among MRT groups and significant differences among groups include presence of alders, extent of channel shading and substrate diversity. Also, the percentage of in-stream organic substrates, in particular CPOM/Xylal, showed highly significant differences among groups. For practical applications, thresholds for the extent of channel reinforcement (40%) and modification (10%) and for bank alteration (≈30%) were provided, that can be used to guide the implementation of restoration measures. In moderately altered river reaches, a significant extent of tree-related habitats (≈5%) can noticeably mitigate the effects of morphological alteration on aquatic invertebrates. The outcomes highlight the importance of riparian zone management as an opportune, achievable prospect in the restoration of Mediterranean temporary streams. The impact of bank and channel modification on ecological status (sensu WFD) was investigated and the tested benthic metrics, especially those based on abundance data, showed legible differences among MRT groups. Finally, bank and channel modification appears to be a potential threat for the conservation of a few Sardo-Corsican endemic species. The introduction of management criteria that

  10. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  11. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly r...

  12. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  13. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  14. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  15. Blocked Urethral Valves

    Science.gov (United States)

    ... if any damage has occurred to the upper urinary tract. Your pediatrician will consult with a pediatric nephrologist (kidney specialist) or nurologist, who may recommend surgery to remove the obstructing valves and prevent further infection or damage to the kidneys or urinary system. ...

  16. Tricuspid valve endocarditis

    Science.gov (United States)

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  17. Equivalence of Linear MMSE Detection in DS-CDMA and MC-CDMA Systems over Time and Frequency Selective Channels

    Directory of Open Access Journals (Sweden)

    Tamer A. Kadous

    2003-01-01

    Full Text Available The goal of this paper is to compare the performance of the linear minimum mean square error (MMSE detector for a class of code division multiple access (CDMA systems in time and frequency selective channels. Specifically, we consider direct sequence (DS-CDMA, multicarrier (MC-CDMA, and the MC-DS-CDMA systems. Two key tools are used in our development. First, a general time-frequency framework that includes the different CDMA systems as special cases. Second, the duality between time and frequency domains that is used to derive equivalences between the different CDMA systems operating over purely frequency selective and purely time selective channels. We then combine the insights obtained from these special cases to assess the performance of CDMA systems over time and frequency selective channels. We provide sufficient conditions for the codes employed by the CDMA systems for the equivalences to hold. Numerical results are presented to illustrate the results.

  18. Piezoelectric and Sensitivity Evaluation of Acoustic Emission Sensors for Nuclear Power Plant Valve

    International Nuclear Information System (INIS)

    Lee, Sang-Guk; Lee, Sun-Ki; Park, Sung-Keun; Kim, Myung-Ki

    2008-01-01

    A lot of valves are used in the power plant. The operation safety test and the valve inside leak detection are implemented on the valve which has a great impact on the safe operation of the plant. While input and output pressure measurement using a pressure gauge, temperature change and the humidity measurement, and pressure-resistant test are used for the valve leak detection, there are many problems such as the difficulty of the real time measurement at the minute leak situation, complexity of the pressure gauge correction and the process of the pressure measurement, and the reliability of the measured value. Therefore, it is necessary to develop the valve leak detection system using the acoustic emission (AE) method which is fast and accurate, and allows the real time measurement and evaluation of the minute leak situation. The valve leak detection method using the AE method is a convenient way to detect the sound of the leak outside the valve in case of existing leak inside of the valve, and the research is in progress recently to apply the method to the power plant valve

  19. Interlayer quality dependent graphene spin valve

    International Nuclear Information System (INIS)

    Iqbal, Muhammad Zahir; Hussain, Ghulam; Siddique, Salma; Iqbal, Muhammad Waqas; Murtaza, Ghulam; Ramay, Shahid Mahmood

    2017-01-01

    It is possible to utilize the new class of materials for emerging two-dimensional (2D) spintronic applications. Here, the role of defects in the graphene interlayer and its influence on the spin valve signal is reported. The emergence of D peak in Raman spectrum reveals defects in the graphene layer. The linear I-V curve for defective and non-defective graphene samples indicate the ohmic nature of NiFe and graphene contact. A non-uniform magnetoresistive effect with a bump is persistently observed for defective graphene device at various temperatures, while a smooth and symmetric signal is detected for non-defective graphene spin valve. Parallel and antiparallel alignments of magnetization of magnetic materials shows low and high resistance states, respectively. The magnetoresistance (MR) ratio for defective graphene NiFe/graphene/NiFe spin valve is measured to be ~0.16% at 300 K which progresses to ~0.39% for non-defective graphene device at the same temperature. Similarly at 4.2 K the MR ratios are reported to be ~0.41% and ~0.78% for defective and non-defective graphene devices, respectively. Our investigation provides an evidence for relatively better response of the spin valve signal with high quality graphene interlayer.

  20. Interlayer quality dependent graphene spin valve

    Energy Technology Data Exchange (ETDEWEB)

    Iqbal, Muhammad Zahir, E-mail: zahir.upc@gmail.com [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi, Khyber Pakhtunkhwa, 23640 Pakistan (Pakistan); Hussain, Ghulam [Faculty of Engineering Sciences, GIK Institute of Engineering Sciences and Technology, Topi, Khyber Pakhtunkhwa, 23640 Pakistan (Pakistan); Siddique, Salma [Department of Bioscience & Biotechnology, Sejong University, Seoul, 143-747 (Korea, Republic of); Iqbal, Muhammad Waqas [Department of Physics, Riphah Institute of Computing and Applied Sciences (RICAS), Riphah International University, Lahore (Pakistan); Murtaza, Ghulam [Centre for Advanced Studies in Physics, Government College University, Lahore 54000 (Pakistan); Ramay, Shahid Mahmood [Physics & Astronomy Department, College of Science, King Saud University, Riyadh 11451 (Saudi Arabia)

    2017-01-15

    It is possible to utilize the new class of materials for emerging two-dimensional (2D) spintronic applications. Here, the role of defects in the graphene interlayer and its influence on the spin valve signal is reported. The emergence of D peak in Raman spectrum reveals defects in the graphene layer. The linear I-V curve for defective and non-defective graphene samples indicate the ohmic nature of NiFe and graphene contact. A non-uniform magnetoresistive effect with a bump is persistently observed for defective graphene device at various temperatures, while a smooth and symmetric signal is detected for non-defective graphene spin valve. Parallel and antiparallel alignments of magnetization of magnetic materials shows low and high resistance states, respectively. The magnetoresistance (MR) ratio for defective graphene NiFe/graphene/NiFe spin valve is measured to be ~0.16% at 300 K which progresses to ~0.39% for non-defective graphene device at the same temperature. Similarly at 4.2 K the MR ratios are reported to be ~0.41% and ~0.78% for defective and non-defective graphene devices, respectively. Our investigation provides an evidence for relatively better response of the spin valve signal with high quality graphene interlayer.

  1. Isolation valve control device for nuclear power plant

    International Nuclear Information System (INIS)

    Yukinori, Shigeru.

    1990-01-01

    The present invention provides an isolation valve control device for detecting pipeline rupture accidents in a BWR type nuclear power plant at an early stage to close an isolation valve thereby reducing the amout of radioactivity released to the circumstance. That is, isolation valves are disposed in the pipeline for each of the systems in the nuclear power plant and flow ratemeters are disposed to at least two positions in each of the pipelines. If a meaningful difference is shown for the measured values by these flow ratemeters, the isolation valve is closed. In this way, if pipeline rupture such as leak before break (LBB) is caused to a portion of a system pipelines, the measured value from the flow ratemeters at the downstream of the pipeline is lowered. Accordingly, when a meaningful difference is formed between the value of the flow ratematers at the upstream and the downstream, occurrence of pipe rutpture between both of the flow ratemeters can be detected. As a result, the isolation valves of the system can be closed. According to the present invention, it is possible to detect the pipeline rupture at an early stage irrespective of the kind of the systems, diameter of the pipelines and the magnitude of the ruptured area, and the isolation valve can be closed. (I.S.)

  2. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part I: design and optimization of bioluminescent bacterial strains

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Durand, Marie-Jose; Jouanneau, Sulivan; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Dion, Michel [UMR CNRS 6204, Nantes University, PRES UNAM, Biotechnologie, Biocatalyse, Bioregulation, 2, Rue de la Houssiniere, BP 92208, Nantes cedex 3 (France); Pernetti, Mimma; Poncelet, Denis [ONIRIS-ENITIAA, UMR CNRS GEPEA, Rue de la Geraudiere, BP 82225, Nantes cedex 3 (France)

    2011-05-15

    This study describes the construction of inducible bioluminescent strains via genetic engineering along with their characterization and optimization in the detection of heavy metals. Firstly, a preliminary comparative study enabled us to select a suitable carbon substrate from pyruvate, glucose, citrate, diluted Luria-Bertani, and acetate. The latter carbon source provided the best induction ratios for comparison. Results showed that the three constructed inducible strains, Escherichia coli DH1 pBzntlux, pBarslux, and pBcoplux, were usable when conducting a bioassay after a 14-h overnight culture at 30 C. Utilizing these sensors gave a range of 12 detected heavy metals including several cross-detections. Detection limits for each metal were often close to and sometimes lower than the European standards for water pollution. Finally, in order to maintain sensitive bacteria within the future biosensor-measuring cell, the agarose immobilization matrix was compared to polyvinyl alcohol (PVA). Agarose was selected because the detection limits of the bioluminescent strains were not affected, in contrast to PVA. Specific detection and cross-detection ranges determined in this study will form the basis of a multiple metals detection system by the new multi-channel Lumisens3 biosensor. (orig.)

  3. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  4. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  5. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  6. Analysis of anabolic steroids in body fluids by capillary gas chromatography with a two-channel detection system and a computer.

    Science.gov (United States)

    Uralets, V P; Semenova, V A; Yakushin, M A; Semenov, V A

    1983-11-25

    A method is described for analysis of multi-component mixtures of steroid metabolites in biological fluids by means of capillary gas chromatography with glass and fused-silica columns and simultaneous detection of methoxylamine-trimethylsilyl derivatives with universal flame-ionization and selective nitrogen alkali flameionization detectors. A data system was applied to the on-line treatment of the results. Computer programs were designed for precise calculation of Kováts retention indices from the known values for selected natural urinary steroids. The programs allow the selection of nitrogen-containing components, normalized chromatogram plotting for both detection channels and qualitative and quantitative analysis. Results are presented on the detection of metabolites of methandrostenolone, 17 alpha-methyltestosterone, 19-nortestosterone and fluoxymesterone.

  7. Marine target detection in quad-pol synthetic aperture radar imagery based on the relative phase of cross-polarized channels

    Science.gov (United States)

    Wang, Yunhua; Li, Huimin; Zhang, Yanmin; Guo, Lixin

    2015-01-01

    A focus on marine target detection in noise corrupted fully polarimetric synthetic aperture radar (SAR) is presented. The property of the relative phase between two cross-polarized channels reveals that the relative phases evaluated within sea surface area or noise corrupted area are widely spread phase angle region [-π,π] due to decorrelation effect; however, the relative phases are concentrated to zero and ±π for real target and its first-order azimuth ambiguities (FOAAs), respectively. Exploiting this physical behavior, the reciprocal of the mean square value of the relative phase (RMSRP) is defined as a new parameter for target detection, and the experiments based on fully polarimetric Radarsat-2 SAR images show that the strong noise and the FOAAs can be effectively suppressed in RMSRP image. Meanwhile, validity of the new parameter for target detection is also verified by two typical Radarsat-2 SAR images, in which targets' ambiguities and strong noise are present.

  8. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  9. Leak processing system for valve gland portion

    International Nuclear Information System (INIS)

    Nishino, Masami

    1990-01-01

    When a process fluid for a valve to be checked is at such a normal temperature as during reactor operation, leaked fluid can be detected depending on the temperature increase accompanying the leakage. However, detection is difficult if the temperature of the process fluid for the valve to be checked is low and, if leakage is detected after the reactor start-up, repair has to be applied after the shutdown of the plant. Then, gland leak is detected by detecting the pressure instead of the temperature in the pipeline system and the leak flow rate is calculated based on the pressure. As a result, leakage is detected irrespective of the temperature of the leaked fluid and, for instance, leakage can be detected even in a case where the temperature is not high as in the case of pressure proof test for the pressure vessel before start-up. It can contribute much to the improvement of the plant operation efficiency and can determine the leak flow rate at a high accuracy. (N.H.)

  10. Resting multilayer 2D speckle-tracking TTE for detection of ischemic segments confirmed by invasive FFR part-2, using post-systolic-strain-index and time from aortic-valve-closure to regional peak longitudinal-strain.

    Science.gov (United States)

    Ozawa, Koya; Funabashi, Nobusada; Nishi, Takeshi; Takahara, Masayuki; Fujimoto, Yoshihide; Kamata, Tomoko; Kobayashi, Yoshio

    2016-08-15

    This study evaluated the post-systolic strain index (PSI), and the time interval between aortic valve closure (AVC) and regional peak longitudinal strain (PLS), measured by transthoracic echocardiography (TTE), for detection of left ventricular (LV) myocardial ischemic segments confirmed by invasive fractional flow reserve (FFR). 39 stable patients (32 males; 65.8±11.9years) with 46 coronary arteries at ≥50% stenosis on invasive coronary angiography underwent 2D speckle tracking TTE (Vivid E9, GE Healthcare) and invasive FFR measurements. PSI, AVC and regional PLS in each LV segment were calculated. FFR ≤0.80 was detected in 27 LV segments. There were no significant differences between segments supplied by FFR ≤0.80 and FFR >0.80 vessels in either PSI or the time interval between AVC and regional PLS. To identify LV segments±FFR ≤0.80, the receiver operator characteristic (ROC) curves for PSI, and the time interval between AVC and regional PLS had areas under the curve (AUC) values of 0.58 and 0.57, respectively, with best cut-off points of 12% (sensitivity 70.4%, specificity 57.9%) and 88ms (sensitivity 70.4%, specificity 52.6%), respectively, but the AUCs were not statistically significant. In stable coronary artery disease patients with ≥50% coronary artery stenosis, measurement of PSI, and the time interval between AVC and regional PLS, on resting TTE, enabled the identification of LV segments with FFR ≤0.80 using each appropriate threshold for PSI, and the time interval between AVC and regional PLS, with reasonable diagnostic accuracy. However, the AUC values were not statistically significant. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  11. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  12. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  13. Design, fabrication and characterization of an arrayable all-polymer microfluidic valve employing highly magnetic rare-earth composite polymer

    International Nuclear Information System (INIS)

    Rahbar, Mona; Gray, Bonnie L; Shannon, Lesley

    2016-01-01

    We present a new magnetically actuated microfluidic valve that employs a highly magnetic composite polymer (M-CP) containing rare-earth hard-magnetic powder for its actuating element and for its valve seat. The M-CP offers much higher magnetization compared to the soft-magnetic, ferrite-based composite polymers typically used in microfluidic applications. Each valve consists of a permanently magnetized M-CP flap and valve seat mounted on a microfluidic channel system fabricated in poly(dimethylsiloxane) (PDMS). Each valve is actuated under a relatively small external magnetic field of 80 mT provided by a small permanent magnet mounted on a miniature linear actuator. The performance of the valve with different flap thicknesses is characterized. In addition, the effect of the magnetic valve seat on the valve’s performance is also characterized. It is experimentally shown that a valve with a 2.3 mm flap thickness, actuated under an 80 mT magnetic field, is capable of completely blocking liquid flow at a flow rate of 1 ml min −1 for pressures up to 9.65 kPa in microfluidic channels 200 μ m wide and 200 μ m deep. The valve can also be fabricated into an array for flow switching between multiple microfluidic channels under continuous flow conditions. The performance of arrays of valves for flow routing is demonstrated for flow rates up to 5 ml min −1 with larger microfluidic channels of up to 1 mm wide and 500 μ m deep. The design of the valves is compatible with other commonly used polymeric microfluidic components, as well as other components that use the same novel permanently magnetic composite polymer, such as our previously reported cilia-based mixing devices. (paper)

  14. Performance Analysis of Heterodyne-Detected OCDMA Systems Using PolSK Modulation over a Free-Space Optical Turbulence Channel

    Directory of Open Access Journals (Sweden)

    Fan Bai

    2015-10-01

    Full Text Available This paper presents a novel model of heterodyne-detected optical code-division multiple-access (OCDMA systems employing polarization shift keying (PolSK modulation over a free-space optical (FSO turbulence channel. In this article, a new transceiver configuration and detailed analytical model for the proposed system are provided and discussed, taking into consideration the potential of heterodyne detection on mitigating the impact of turbulence-induced irradiance fluctuation on the performance of the proposed system under the gamma-gamma turbulence channel. Furthermore, we derived the closed-form expressions for the system error probability and outage probability, respectively. We determine the advantages of the proposed modeling by performing a comparison with a direct detection scheme obtained from an evaluation of link performance under the same environment conditions. The presented work also shows the most significant impact factor that degrades the performance of the proposed system and indicates that the proposed approach offers an optimum link performance compared to conventional cases.

  15. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  16. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  17. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  18. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  19. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  20. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms • Accurate Diagnosis • Treatment Options • Recovery and ...

  1. TU-FG-209-11: Validation of a Channelized Hotelling Observer to Optimize Chest Radiography Image Processing for Nodule Detection: A Human Observer Study

    International Nuclear Information System (INIS)

    Sanchez, A; Little, K; Chung, J; Lu, ZF; MacMahon, H; Reiser, I

    2016-01-01

    Purpose: To validate the use of a Channelized Hotelling Observer (CHO) model for guiding image processing parameter selection and enable improved nodule detection in digital chest radiography. Methods: In a previous study, an anthropomorphic chest phantom was imaged with and without PMMA simulated nodules using a GE Discovery XR656 digital radiography system. The impact of image processing parameters was then explored using a CHO with 10 Laguerre-Gauss channels. In this work, we validate the CHO’s trend in nodule detectability as a function of two processing parameters by conducting a signal-known-exactly, multi-reader-multi-case (MRMC) ROC observer study. Five naive readers scored confidence of nodule visualization in 384 images with 50% nodule prevalence. The image backgrounds were regions-of-interest extracted from 6 normal patient scans, and the digitally inserted simulated nodules were obtained from phantom data in previous work. Each patient image was processed with both a near-optimal and a worst-case parameter combination, as determined by the CHO for nodule detection. The same 192 ROIs were used for each image processing method, with 32 randomly selected lung ROIs per patient image. Finally, the MRMC data was analyzed using the freely available iMRMC software of Gallas et al. Results: The image processing parameters which were optimized for the CHO led to a statistically significant improvement (p=0.049) in human observer AUC from 0.78 to 0.86, relative to the image processing implementation which produced the lowest CHO performance. Conclusion: Differences in user-selectable image processing methods on a commercially available digital radiography system were shown to have a marked impact on performance of human observers in the task of lung nodule detection. Further, the effect of processing on humans was similar to the effect on CHO performance. Future work will expand this study to include a wider range of detection/classification tasks and more

  2. Flow cytometric-membrane potential detection of sodium channel active marine toxins: application to ciguatoxins in fish muscle and feasibility of automating saxitoxin detection.

    Science.gov (United States)

    Manger, Ronald; Woodle, Doug; Berger, Andrew; Dickey, Robert W; Jester, Edward; Yasumoto, Takeshi; Lewis, Richard; Hawryluk, Timothy; Hungerford, James

    2014-01-01

    Ciguatoxins are potent neurotoxins with a significant public health impact. Cytotoxicity assays have allowed the most sensitive means of detection of ciguatoxin-like activity without reliance on mouse bioassays and have been invaluable in studying outbreaks. An improvement of these cell-based assays is presented here in which rapid flow cytometric detection of ciguatoxins and saxitoxins is demonstrated using fluorescent voltage sensitive dyes. A depolarization response can be detected directly due to ciguatoxin alone; however, an approximate 1000-fold increase in sensitivity is observed in the presence of veratridine. These results demonstrate that flow cytometric assessment of ciguatoxins is possible at levels approaching the trace detection limits of our earlier cytotoxicity assays, however, with a significant reduction in analysis time. Preliminary results are also presented for detection of brevetoxins and for automation and throughput improvements to a previously described method for detecting saxitoxins in shellfish extracts.

  3. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  4. [Periodontal microbiota and microorganisms isolated from heart valves in patients undergoing valve replacement surgery in a clinic in Cali, Colombia].

    Science.gov (United States)

    Moreno, Sandra; Parra, Beatriz; Botero, Javier E; Moreno, Freddy; Vásquez, Daniel; Fernández, Hugo; Alba, Sandra; Gallego, Sara; Castillo, Gilberto; Contreras, Adolfo

    2017-12-01

    Periodontitis is an infectious disease that affects the support tissue of the teeth and it is associated with different systemic diseases, including cardiovascular disease. Microbiological studies facilitate the detection of microorganisms from subgingival and cardiovascular samples. To describe the cultivable periodontal microbiota and the presence of microorganisms in heart valves from patients undergoing valve replacement surgery in a clinic in Cali. We analyzed 30 subgingival and valvular tissue samples by means of two-phase culture medium, supplemented blood agar and trypticase soy agar with antibiotics. Conventional PCR was performed on samples of valve tissue. The periodontal pathogens isolated from periodontal pockets were: Fusobacterium nucleatum (50%), Prevotella intermedia/ nigrescens (40%), Campylobacter rectus (40%), Eikenella corrodens (36.7%), Gram negative enteric bacilli (36.7%), Porphyromonas gingivalis (33.3%), and Eubacterium spp. (33.3%). The pathogens isolated from the aortic valve were Propionibacterium acnes (12%), Gram negative enteric bacilli (8%), Bacteroides merdae (4%), and Clostridium bifermentans (4%), and from the mitral valve we isolated P. acnes and Clostridium beijerinckii. Conventional PCR did not return positive results for oral pathogens and bacterial DNA was detected only in two samples. Periodontal microbiota of patients undergoing surgery for heart valve replacement consisted of species of Gram-negative bacteria that have been associated with infections in extraoral tissues. However, there is no evidence of the presence of periodontal pathogens in valve tissue, because even though there were valve and subgingival samples positive for Gram-negative enteric bacilli, it is not possible to maintain they corresponded to the same phylogenetic origin.

  5. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  6. BNGS B valve packing program

    International Nuclear Information System (INIS)

    Cumming, D.

    1995-01-01

    The Bruce B Valve Packing Program began in 1987. The early history and development were presented at the 1992 International CANDU Maintenance conference. This presentation covers the evolution of the Bruce B Valve Packing Program over the period 1992 to 1995. (author)

  7. Highly selective micro-sequential injection lab-on-valve (muSI-LOV) method for the determination of ultra-trace concentrations of nickel in saline matrices using detection by electrothermal atomic absorption spectrometry.

    Science.gov (United States)

    Long, Xiangbao; Miró, Manuel; Jensen, Rikard; Hansen, Elo Harald

    2006-10-01

    A highly selective procedure is proposed for the determination of ultra-trace level concentrations of nickel in saline aqueous matrices exploiting a micro-sequential injection Lab-On-Valve (muSI-LOV) sample pretreatment protocol comprising bead injection separation/pre-concentration and detection by electrothermal atomic absorption spectrometry (ETAAS). Based on the dimethylglyoxime (DMG) reaction used for nickel analysis, the sample, as contained in a pH 9.0 buffer, is, after on-line merging with the chelating reagent, transported to a reaction coil attached to one of the external ports of the LOV to assure sufficient reaction time for the formation of Ni(DMG)(2) chelate. The non-ionic coordination compound is then collected in a renewable micro-column packed with a reversed-phase copolymeric sorbent [namely, poly(divinylbenzene-co-N-vinylpyrrolidone)] containing a balanced ratio of hydrophilic and lipophilic monomers. Following elution by a 50-muL methanol plug in an air-segmented modality, the nickel is finally quantified by ETAAS. Under the optimized conditions and for a sample volume of 1.8 mL, a retention efficiency of 70 % and an enrichment factor of 25 were obtained. The proposed methodology showed a high tolerance to the commonly encountered alkaline earth matrix elements in environmental waters, that is, calcium and magnesium, and was successfully applied for the determination of nickel in an NIST standard reference material (NIST 1640-Trace elements in natural water), household tap water of high hardness and local seawater. Satisfying recoveries were achieved for all spiked environmental water samples with maximum deviations of 6 %. The experimental results for the standard reference material were not statistically different to the certified value at a significance level of 0.05.

  8. On Low-Complexity Full-diversity Detection In Multi-User MIMO Multiple-Access Channels

    KAUST Repository

    Ismail, Amr

    2014-01-28

    Multiple-input multiple-output (MIMO) techniques are becoming commonplace in recent wireless communication standards. This newly introduced dimension (i.e., space) can be efficiently used to mitigate the interference in the multi-user MIMO context. In this paper, we focus on the uplink of a MIMO multiple access channel (MAC) where perfect channel state information (CSI) is only available at the destination. We provide new sufficient conditions for a wide range of space-time block codes (STBC)s to achieve full-diversity under partial interference cancellation group decoding (PICGD) with or without successive interference cancellation (SIC) for completely blind users. Interference cancellation (IC) schemes for two and three users are then provided and shown to satisfy the full-diversity criteria. Beside the complexity reduction due to the fact that PICGD enables separate decoding of distinct users without sacrificing the diversity gain, further reduction of the decoding complexity may be obtained. In fact, thanks to the structure of the proposed schemes, the real and imaginary parts of each user\\'s symbols may be decoupled without any loss of performance. Our new IC scheme is shown to outperform recently proposed two-user IC scheme especially for high spectral efficiency while requiring significantly less decoding complexity.

  9. On Low-Complexity Full-diversity Detection In Multi-User MIMO Multiple-Access Channels

    KAUST Repository

    Ismail, Amr; Alouini, Mohamed-Slim

    2014-01-01

    Multiple-input multiple-output (MIMO) techniques are becoming commonplace in recent wireless communication standards. This newly introduced dimension (i.e., space) can be efficiently used to mitigate the interference in the multi-user MIMO context. In this paper, we focus on the uplink of a MIMO multiple access channel (MAC) where perfect channel state information (CSI) is only available at the destination. We provide new sufficient conditions for a wide range of space-time block codes (STBC)s to achieve full-diversity under partial interference cancellation group decoding (PICGD) with or without successive interference cancellation (SIC) for completely blind users. Interference cancellation (IC) schemes for two and three users are then provided and shown to satisfy the full-diversity criteria. Beside the complexity reduction due to the fact that PICGD enables separate decoding of distinct users without sacrificing the diversity gain, further reduction of the decoding complexity may be obtained. In fact, thanks to the structure of the proposed schemes, the real and imaginary parts of each user's symbols may be decoupled without any loss of performance. Our new IC scheme is shown to outperform recently proposed two-user IC scheme especially for high spectral efficiency while requiring significantly less decoding complexity.

  10. A novel strategy for dual-channel detection of metallothioneins and mercury based on the conformational switching of functional chimera aptamer.

    Science.gov (United States)

    Tang, Xian; Wang, Yong-Sheng; Xue, Jin-Hua; Zhou, Bin; Cao, Jin-Xiu; Chen, Si-Han; Li, Ming-Hui; Wang, Xiao-Feng; Zhu, Yu-Feng; Huang, Yan-Qin

    2015-03-25

    A novel strategy for dual-channel detection of metallothioneins (MTs) and Hg(2+) has been proposed. In the absence of Hg(2+), the functional chimera aptamer (FCA) designed can form an intact G-quadruplex with flexibility, which was demonstrated to have peroxidase-like activities upon hemin binding. In the presence of Hg(2+), the formation of T-Hg(2+)-T complex results in the conformational switching of FCA, which lost the peroxidase-like activities and cannot catalyze the oxidation of ABTS by H2O2. Upon addition of MTs in this solution, MTs could interact with Hg(2+) to form a MTs-Hg(2+) complex, leading to the recovery of the G-quadruplex DNAzyme. The color and absorbance of the sensing system were also changed accordingly. In the optimizing condition, ΔA was directly proportional to the concentration ranging from 8.84 nM to 1.0 μM for Hg(2+), and 7.82 nM to 0.462 μM for MTs with the detection limits of 2.65 nM and 2.34 nM, respectively. The proposed dual-channel method avoids the label steps in common methods, and allows direct analysis of the samples without costly instruments, and is reliable, inexpensive and sensitive. Copyright © 2015 Elsevier B.V. All rights reserved.

  11. Adaptive Holography in Liquid Crystal Light-Valves

    Directory of Open Access Journals (Sweden)

    Jean-Pierre Huignard

    2012-08-01

    Full Text Available By performing two-wave mixing experiments in a liquid crystal light-valve, optical beam amplification is obtained as a strongly resonant process to which a narrow frequency bandwidth is associated. This property is exploited to realize adaptive holographic interferometric systems able to efficiently detect displacements as small as fraction of picometers. Pressure radiation induced deformations of a reflecting membrane are measured with the same type of system. Then, when used with complex wavefronts, like speckle fields, the LCLV-based interferometer allows to detect extremely small phase modulations. The examples shown demonstrate the potentialities of the light-valve for dynamic holography applications.

  12. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  13. Very Fast Algorithms and Detection Performance of Multi-Channel and 2-D Parametric Adaptive Matched Filters for Airborne Radar

    National Research Council Canada - National Science Library

    Marple, Jr., S. L; Corbell, Phillip M; Rangaswamy, Muralidhar

    2007-01-01

    ...) detection statistics under exactly known covariance (the clairvoyant case). Improved versions of the two original multichannel PAMF algorithms, one new multichannel PAMF algorithm, and a new two-dimensional (2D) PAMF algorithm...

  14. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  15. PARAMETER ESTIMATION OF VALVE STICTION USING ANT COLONY OPTIMIZATION

    Directory of Open Access Journals (Sweden)

    S. Kalaivani

    2012-07-01

    Full Text Available In this paper, a procedure for quantifying valve stiction in control loops based on ant colony optimization has been proposed. Pneumatic control valves are widely used in the process industry. The control valve contains non-linearities such as stiction, backlash, and deadband that in turn cause oscillations in the process output. Stiction is one of the long-standing problems and it is the most severe problem in the control valves. Thus the measurement data from an oscillating control loop can be used as a possible diagnostic signal to provide an estimate of the stiction magnitude. Quantification of control valve stiction is still a challenging issue. Prior to doing stiction detection and quantification, it is necessary to choose a suitable model structure to describe control-valve stiction. To understand the stiction phenomenon, the Stenman model is used. Ant Colony Optimization (ACO, an intelligent swarm algorithm, proves effective in various fields. The ACO algorithm is inspired from the natural trail following behaviour of ants. The parameters of the Stenman model are estimated using ant colony optimization, from the input-output data by minimizing the error between the actual stiction model output and the simulated stiction model output. Using ant colony optimization, Stenman model with known nonlinear structure and unknown parameters can be estimated.

  16. Large spin-valve effect in a lateral spin-valve device based on ferromagnetic semiconductor GaMnAs

    Science.gov (United States)

    Asahara, Hirokatsu; Kanaki, Toshiki; Ohya, Shinobu; Tanaka, Masaaki

    2018-03-01

    We investigate the spin-dependent transport properties of a lateral spin-valve device based on the ferromagnetic semiconductor GaMnAs. This device is composed of a GaMnAs channel layer grown on GaAs with a narrow trench across the channel. Its current-voltage characteristics show tunneling behavior. Large magnetoresistance (MR) ratios of more than ˜10% are obtained. These values are much larger than those (˜0.1%) reported for lateral-type spin metal-oxide-semiconductor field-effect transistors. The magnetic field direction dependence of the MR curve differs from that of the anisotropic magnetoresistance of GaMnAs, which confirms that the MR signal originates from the spin-valve effect between the GaMnAs electrodes.

  17. Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms

    Energy Technology Data Exchange (ETDEWEB)

    Yu Lifeng; Leng Shuai; Chen Lingyun; Kofler, James M.; McCollough, Cynthia H. [Department of Radiology, Mayo Clinic, Rochester, Minnesota 55905 (United States); Carter, Rickey E. [Division of Biomedical Statistics and Informatics, Mayo Clinic, Rochester, Minnesota 55905 (United States)

    2013-04-15

    Purpose: Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. Methods: A 35 Multiplication-Sign 26 cm{sup 2} torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was -15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. Results: The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The

  18. Prediction of human observer performance in a 2-alternative forced choice low-contrast detection task using channelized Hotelling observer: Impact of radiation dose and reconstruction algorithms

    International Nuclear Information System (INIS)

    Yu Lifeng; Leng Shuai; Chen Lingyun; Kofler, James M.; McCollough, Cynthia H.; Carter, Rickey E.

    2013-01-01

    Purpose: Efficient optimization of CT protocols demands a quantitative approach to predicting human observer performance on specific tasks at various scan and reconstruction settings. The goal of this work was to investigate how well a channelized Hotelling observer (CHO) can predict human observer performance on 2-alternative forced choice (2AFC) lesion-detection tasks at various dose levels and two different reconstruction algorithms: a filtered-backprojection (FBP) and an iterative reconstruction (IR) method. Methods: A 35 × 26 cm 2 torso-shaped phantom filled with water was used to simulate an average-sized patient. Three rods with different diameters (small: 3 mm; medium: 5 mm; large: 9 mm) were placed in the center region of the phantom to simulate small, medium, and large lesions. The contrast relative to background was −15 HU at 120 kV. The phantom was scanned 100 times using automatic exposure control each at 60, 120, 240, 360, and 480 quality reference mAs on a 128-slice scanner. After removing the three rods, the water phantom was again scanned 100 times to provide signal-absent background images at the exact same locations. By extracting regions of interest around the three rods and on the signal-absent images, the authors generated 21 2AFC studies. Each 2AFC study had 100 trials, with each trial consisting of a signal-present image and a signal-absent image side-by-side in randomized order. In total, 2100 trials were presented to both the model and human observers. Four medical physicists acted as human observers. For the model observer, the authors used a CHO with Gabor channels, which involves six channel passbands, five orientations, and two phases, leading to a total of 60 channels. The performance predicted by the CHO was compared with that obtained by four medical physicists at each 2AFC study. Results: The human and model observers were highly correlated at each dose level for each lesion size for both FBP and IR. The Pearson's product

  19. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  20. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  1. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  2. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  3. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  4. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  5. ASEP of MIMO System with MMSE-OSIC Detection over Weibull-Gamma Fading Channel Subject to AWGGN

    Directory of Open Access Journals (Sweden)

    Keerti Tiwari

    2016-01-01

    Full Text Available Ordered successive interference cancellation (OSIC is adopted with minimum mean square error (MMSE detection to enhance the multiple-input multiple-output (MIMO system performance. The optimum detection technique improves the error rate performance but increases system complexity. Therefore, MMSE-OSIC detection is used which reduces error rate compared to traditional MMSE with low complexity. The system performance is analyzed in composite fading environment that includes multipath and shadowing effects known as Weibull-Gamma (WG fading. Along with the composite fading, a generalized noise that is additive white generalized Gaussian noise (AWGGN is considered to show the impact of wireless scenario. This noise model includes various forms of noise as special cases such as impulsive, Gamma, Laplacian, Gaussian, and uniform. Consequently, generalized Q-function is used to model noise. The average symbol error probability (ASEP of MIMO system is computed for 16-quadrature amplitude modulation (16-QAM using MMSE-OSIC detection in WG fading perturbed by AWGGN. Analytical expressions are given in terms of Fox-H function (FHF. These expressions demonstrate the best fit to simulation results.

  6. Sensor-Free or Sensor-Full: A Comparison of Data Modalities in Multi-Channel Affect Detection

    Science.gov (United States)

    Paquette, Luc; Rowe, Jonathan; Baker, Ryan; Mott, Bradford; Lester, James; DeFalco, Jeanine; Brawner, Keith; Sottilare, Robert; Georgoulas, Vasiliki

    2016-01-01

    Computational models that automatically detect learners' affective states are powerful tools for investigating the interplay of affect and learning. Over the past decade, affect detectors--which recognize learners' affective states at run-time using behavior logs and sensor data--have advanced substantially across a range of K-12 and postsecondary…

  7. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  8. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  9. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  10. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  11. Acoustic emission condition monitoring of a nuclear power plant check valve using artificial neural networks

    International Nuclear Information System (INIS)

    Lee, Joon Hyun; Lee, Min Rae; Kim, Jung Teak

    2005-01-01

    In this study, an advanced condition monitoring technique based on acoustic emission (AE) detection and artificial neural networks was applied to a check valve, one of the components being used extensively in a safety system of a nuclear power plant (Npp). AE testing for a check valve under controlled flow loop conditions was performed to detect and evaluate disk movement for valve degradation such as wear and leakage due to foreign object interference in a check valve. It is clearly demonstrated that the evaluation of different types of failure modes such as disk wear and check valve leakage were successful by systematically analyzing the characteristics of various AE parameters. It is also shown that the leak size can be determined with an artificial neural network

  12. Determination of trace metal ions via on-line separation and preconcentration by means of chelating Sepharose beads in a sequential injection lab-on-valve (SI-LOV) system coupled to electrothermal atomic absorption spectrometric detection

    DEFF Research Database (Denmark)

    Long, Xiangbao; Hansen, Elo Harald; Miró, Manuel

    2005-01-01

    The analytical performance of an on-line sequential injection lab-on-valve (SI-LOV) system using chelating Sepharose beads as sorbent material for the determination of ultra trace levels of Cd(II), Pb(II) and Ni(II) by electrothermal atomic absorption spectrometry (ETAAS) is described and discussed...

  13. Task-based detectability comparison of exponential transformation of free-response operating characteristic (EFROC) curve and channelized Hotelling observer (CHO)

    Science.gov (United States)

    Khobragade, P.; Fan, Jiahua; Rupcich, Franco; Crotty, Dominic J.; Gilat Schmidt, Taly

    2016-03-01

    This study quantitatively evaluated the performance of the exponential transformation of the free-response operating characteristic curve (EFROC) metric, with the Channelized Hotelling Observer (CHO) as a reference. The CHO has been used for image quality assessment of reconstruction algorithms and imaging systems and often it is applied to study the signal-location-known cases. The CHO also requires a large set of images to estimate the covariance matrix. In terms of clinical applications, this assumption and requirement may be unrealistic. The newly developed location-unknown EFROC detectability metric is estimated from the confidence scores reported by a model observer. Unlike the CHO, EFROC does not require a channelization step and is a non-parametric detectability metric. There are few quantitative studies available on application of the EFROC metric, most of which are based on simulation data. This study investigated the EFROC metric using experimental CT data. A phantom with four low contrast objects: 3mm (14 HU), 5mm (7HU), 7mm (5 HU) and 10 mm (3 HU) was scanned at dose levels ranging from 25 mAs to 270 mAs and reconstructed using filtered backprojection. The area under the curve values for CHO (AUC) and EFROC (AFE) were plotted with respect to different dose levels. The number of images required to estimate the non-parametric AFE metric was calculated for varying tasks and found to be less than the number of images required for parametric CHO estimation. The AFE metric was found to be more sensitive to changes in dose than the CHO metric. This increased sensitivity and the assumption of unknown signal location may be useful for investigating and optimizing CT imaging methods. Future work is required to validate the AFE metric against human observers.

  14. FAILURE MODE AND EFFECT ANALYSIS (FMEA OF BUTTERFLY VALVE IN OIL AND GAS INDUSTRY

    Directory of Open Access Journals (Sweden)

    MUHAMMAD AMIRUL BIN YUSOF

    2016-04-01

    Full Text Available Butterfly valves are mostly used in various industries such as oil and gas plant. This valve operates with rotating motion using pneumatic system. Rotating actuator turns the disc either parallel or perpendicular to the flow. When the valve is fully open, the disc is rotated a quarter turn so that it allows free passage of the fluid and when fully closed, the disc rotated a quarter turns to block the fluid. The primary failure modes for valves are the valve leaks to environment through flanges, seals on the valve body, valve stem packing not properly protected, over tightened packing nuts, the valve cracks and leaks over the seat. To identify the failure of valve Failure Mode and Effects Analysis has been chosen. FMEA is the one of technique to perform failure analysis. It involves reviewing as many components to identify failure modes, and their causes and effects. For each component, the failure modes and their resulting effects on the rest of the system are recorded in a specific FMEA form. Risk priority number, severity, detection, occurrence are the factor determined in this studies. Risk priority number helps to find out the highest hazardous activities which need more attention than the other activity. The highest score of risk priority number in this research is seat. Action plan was proposed to reduce the risk priority number and so that potential failures also will be reduced.

  15. Options for Heart Valve Replacement

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Cardiac Arrest: How Are They Different? 7 Warning Signs of a Heart Attack 8 Low Blood Pressure - ...

  16. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  17. Development and validation of a 64 channel front end ASIC for 3D directional detection for MIMAC

    International Nuclear Information System (INIS)

    Richer, J P; Bourrion, O; Bosson, G; Guillaudin, O; Mayet, F; Santos, D

    2011-01-01

    A front end ASIC has been designed to equip the μTPC prototype developed for the MIMAC project, which requires 3D reconstruction of low energy particle tracks in order to perform directional detection of galactic Dark Matter. Each ASIC is able to monitor 64 strips of pixels and provides the 'Time Over Threshold' information for each of those. These 64 digital informations, sampled at a rate of 50 MHz, can be transferred at 400 MHz by eight LVDS serial links. Eight ASIC were validated on a 2 × 256 strips of pixels prototype.

  18. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  19. Microstructural information from channeling measurements

    International Nuclear Information System (INIS)

    Quere, Y.

    1984-09-01

    Channeling is sensitive to nearly all structural changes in solids. One briefly recalls how particles are dechanneled by lattice defects and describes the main applications of channeling to materials science: detection of radiation damage, location of impurity atoms, precipitations in alloys... Channeling being a phenomenon characteristic of perfect crystals, any type of lattice imperfection (phonons, crystal defects, precipitation etc.) is expected to produce dechanneling. Consequently channeling and its opposite, dechanneling, have both been used to study structure and structural changes of materials

  20. Perivalvular pannus and valve thrombosis: two concurrent mechanisms of mechanical valve prosthesis dysfunction.

    Science.gov (United States)

    Arnáiz-García, María Elena; González-Santos, Jose María; Bueno-Codoñer, María E; López-Rodríguez, Javier; Dalmau-Sorlí, María José; Arévalo-Abascal, Adolfo; Arribas-Jiménez, Antonio; Diego-Nieto, Alejandro; Rodríguez-Collado, Javier; Rodríguez-López, Jose María

    2015-02-01

    A 78-year-old woman was admitted to our institution with progressive dyspnea. She had previously been diagnosed with rheumatic heart disease and had undergone cardiac surgery for mechanical mitral valve replacement ten years previously. Transesophageal echocardiography revealed blockage of the mechanical prosthesis and the patient was scheduled for surgery, in which a thrombus was removed from the left atrial appendage. A partial thrombosis of the mechanical prosthesis and circumferential pannus overgrowth were concomitantly detected. Prosthetic heart valve blockage is a rare but life-threatening complication, the main causes of which are thrombosis and pannus formation. The two conditions are different but both are usually misdiagnosed. Two concurrent mechanisms of prosthesis blockage were found in this patient. Copyright © 2014 Sociedade Portuguesa de Cardiologia. Published by Elsevier España. All rights reserved.

  1. Advancing satellite-based solar power forecasting through integration of infrared channels for automatic detection of coastal marine inversion layer

    Energy Technology Data Exchange (ETDEWEB)

    Kostylev, Vladimir; Kostylev, Andrey; Carter, Chris; Mahoney, Chad; Pavlovski, Alexandre; Daye, Tony [Green Power Labs Inc., Dartmouth, NS (Canada); Cormier, Dallas Eugene; Fotland, Lena [San Diego Gas and Electric Co., San Diego, CA (United States)

    2012-07-01

    strongest in coastal areas up to 50 km away from coast. Extent of ML inland in SDF and E service area was the largest in May and receded towards coast gradually through summer and fall. The ML probability correlated well with accuracy of solar radiation and PV forecasting in the region. Coastal sites appeared the most challenging for accurate forecast while PV forecasts in inland areas were performing consistently well. Improvement of automated cloud classification algorithms through integration of infrared satellite channels as well as better understanding of meteorological drivers of ML events is the key for improvement of satellite-based PV generation forecasting in coastal areas. (orig.)

  2. Subvalvular pannus and thrombosis in a mitral valve prosthesis.

    Science.gov (United States)

    Kim, Gun Ha; Yang, Dong Hyun; Kang, Joon-Won; Kim, Dae-Hee; Jung, Sung-Ho; Lim, Tae-Hwan

    2016-01-01

    A 69-year-old female underwent cardiac CT to evaluate prosthetic valve (PHV) dysfunction detected on echocardiography. A CT coronal and en face views of the mitral annular plane showed a low-density, mass-like lesion on the left atrial side of the PHV and a high-density, plate-like lesion on the left ventricular side of PHV. A repeat of the mitral valve replacement was performed, and preoperative CT findings of both the thrombus on the left atrial side and pannus formation on the LV side were confirmed in the operative findings. Copyright © 2016 Society of Cardiovascular Computed Tomography. Published by Elsevier Inc. All rights reserved.

  3. A multi-channel bioluminescent bacterial biosensor for the on-line detection of metals and toxicity. Part II: technical development and proof of concept of the biosensor

    Energy Technology Data Exchange (ETDEWEB)

    Charrier, Thomas; Thouand, Gerald [UMR CNRS 6144 GEPEA, CBAC, Nantes University, PRES UNAM, Campus de la Courtaisiere-IUT, La Roche-sur-Yon cedex (France); Chapeau, Cyrille [Biolumine, Biokar Diagnostic, Rue des Quarante Mines ZAC de Ther-Allonne, Beauvais Cedex (France); Bendria, Loubna; Daniel, Philippe [UMR CNRS 6087 LPEC, Universite du Maine, Av Olivier Messiaen, Le Mans cedex 9 (France); Picart, Pascal [UMR CNRS 6613 IAM-LAUM, Ecole Nationale des Ingenieurs du Mans, Universite du Maine, Le Mans Cedex 9 (France)

    2011-05-15

    This research study deals with the on-line detection of heavy metals and toxicity within the context of environmental pollution monitoring. It describes the construction and the proof of concept of a multi-channel bioluminescent bacterial biosensor in immobilized phase: Lumisens3. This new versatile device, designed for the non-stop analysis of water pollution, enables the insertion of any bioluminescent strains (inducible or constitutive), immobilized in a multi-well removable card. The technical design of Lumisens3 has benefited from both a classical and a robust approach and includes four main parts: (1) a dedicated removable card contains 64 wells, 3 mm in depth, arranged in eight grooves within which bacteria are immobilized, (2) this card is incubated on a Pelletier block with a CCD cooled camera on top for bioluminescence monitoring, (3) a fluidic network feeds the card with the sample to be analyzed and finally (4) a dedicated computer interface, BIOLUX 1.0, controls all the elements of the biosensor, allowing it to operate autonomously. The proof of concept of this biosensor was performed using a set of four bioluminescent bacteria (Escherichia coli DH1 pBzntlux, pBarslux, pBcoplux, and E. coli XL1 pBfiluxCDABE) in the on-line detection of CdCl{sub 2} 0.5 {mu}M and As{sub 2}O{sub 3} 5 {mu}M from an influent. When considering metals individually, the ''fingerprints'' from the biosensor were as expected. However, when metals were mixed together, cross reaction and synergistic effects were detected. This biosensor allowed us to demonstrate the simultaneous on-line cross detection of one or several heavy metals as well as the measurement of the overall toxicity of the sample. (orig.)

  4. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  5. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  6. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  7. Soft valves in plants

    Science.gov (United States)

    Park, Keunhwan; Tixier, Aude; Christensen, Anneline; Arnbjerg-Nielsen, Sif; Zwieniecki, Maciej; Jensen, Kaare

    2017-11-01

    Water and minerals flow from plant roots to leaves in the xylem, an interconnected network of vascular conduits that spans the full length of the organism. When a plant is subjected to drought stress, air pockets can spread inside the xylem, threatening the survival of the plant. Many plants prevent propagation of air by using hydrophobic nano-membranes in the ``pit'' pores that link adjacent xylem cells. This adds considerable resistance to flow. Interestingly, torus-margo pit pores in conifers are open and offer less resistance. To prevent propagation of air, conifers use a soft gating mechanism, which relies on hydrodynamic interactions between the xylem liquid and the elastic pit. However, it is unknown exactly how it is able to combine the seemingly antagonist functions of high permeability and resistance to propagation of air. We conduct experiments on biomimetic pores to elucidate the flow regulation mechanism. The design of plant valves is compared to other natural systems and optimal strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.

  8. Annular flow diverter valve

    International Nuclear Information System (INIS)

    Rider, R.L.

    1980-01-01

    A valve is described for diverting flow from the center of two concentric tubes to the annulus between the tubes or, operating in the reverse direction, for mixing fluids from concentric tubes into a common tube and for controlling the volume ratio of said flow. It consists of a toroidal baffle disposed in sliding engagement with the interior of the inner tube downstream of a plurality of ports in the inner tube, a plurality of gates in sliding engagement with the interior of the inner tube attached to the baffle for movement therewith, a servomotor having a bullet-shaped plug on the downstream end thereof, and drive rods connecting the servomotor to the toroidal baffle. The sevomotor is adapted to move the baffle into mating engagement with the bullet-shaped plug and simultaneously move the gates away from the ports in the inner tube and to move the baffle away from the bullet-shaped plug and simultaneously move the gates to cover the ports in the inner tube

  9. Anatomic characteristics of bileaflet mitral valve prolapse--Barlow disease--in patients undergoing mitral valve repair.

    Science.gov (United States)

    Rostagno, Carlo; Droandi, Ginevra; Rossi, Alessandra; Bevilacqua, Sergio; Romagnoli, Stefano; Montesi, Gian Franco; Stefàno, Pier Luigi

    2014-01-01

    Barlow disease is a still challenging pathology for the surgeon. Aim of the present study is to report anatomic abnormalities of mitral valve in patients undergoing mitral valve repair. Between January 1st, 2007, and December 31st, 2010, 85 consecutive patients (54 men and 31 women, mean age 59 +/- 14 years--range: 28-85 years) with the features of a Barlow mitral valve disease underwent mitral repair Forty seven percent of patients were in New York Heart Association functional class III or IV. Preoperative transesophageal echocardiography was compared with anatomical findings at the moment of surgery. Transthoracic echocardiography diagnosis of Barlow disease according to the criteria described by Carpentier was confirmed at anatomical inspection. Annular calcifications were found in 28 patients while 7 patients presented single or multiple clefts. A flail posterior mitral leaflet was detected in 32 subjects, while a flail anterior leaflet in 8. Elongation of chordae tendineae was demonstrated in 45 patients and chordal rupture in 31. All patients showed at trans esophageal echocardiography the typical features of Barlow disease. Seventy-seven (90.6%) patients had severe mitral valve regurgitation, in the remaining 9.4% it was moderate to severe. Transesophageal echocardiography failed to identify clefts in 2/7 and chordal rupture in 4/31. bileaflet prolapse > 2 mm, billowing valve with excess tissue and thickened leaflets > or = 3 mm, and severe annular dilatation, are characteristics of Barlow disease, however the identification of the associated and complex abnormalities of mitral valve is necessary to obtain optimal valve repair.

  10. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  11. The Impact of Vacuum Gate Valves on the LHC Beam

    CERN Document Server

    Appleby, R B; Cerutti, F; Ferrari, A; Mauri, M; Vlachoudis, V

    2009-01-01

    The LHC vacuum sector valves are located in the straight sections of the LHC ring, and designed to sectorize the LHC vacuum. The valves are interlocked and should trigger a beam dump request if they close on a circulating beam. This report studies the impact on the machine if this request is not made and the valve scrapes the LHC beam halo. Cascade calculations are made using a model of IR7, with several different valve locations, to calculate the downstream energy deposition in superconducting magnet coils and the corresponding signal in beam loss monitors at the quench level. The calculations are done at 7, 5, and 3.5 TeV. It is found that when a downstream magnet reaches the quench level, the neighbouring BLMs see a signal well above the detection threshold. Furthermore, the BLM signal is consistent with the BLM applied threshold settings and a signal is seen in the time domain before the quench level is reached. Therefore the report concludes that the BLMs can see the closing valve and trigger a beam dump...

  12. A 3D velocimetry study of the flow through prosthetic heart valves

    Science.gov (United States)

    Ledesma, R.; Zenit, R.; Pulos, G.; Sanchez, E.; Juarez, A.

    2006-11-01

    Blood damage commonly appears in medical valve prothesis. It is a mayor concern for the designers and surgeons. It is well known that this damage and other complications result from the modified fluid dynamics through the replacement valve. To evaluate the performance of prosthetic heart valves, it is necessary to study the flow through them. To conduct this study , we have built a flow channel that emulates cardiac conditions and allows optical access such that a 3D-PIV velocimetry system could be used. The experiments are aimed to reconstruct the downstream structure of the flow through a mechanical and a bio-material tricuspid heart valve prothesis. Preliminary results show that the observed coherent structures can be related with haemolysis and trombosis, illnesses commonly found in valve prothesis recipients. The mean flow, the levels of strain rate and the turbulence intensity generated by the valves can also be directly related to blood damage. In general, bio-material made valves tend to reduce these complications.

  13. On the performance of joint iterative detection and decoding in coherent optical channels with laser frequency fluctuations

    Science.gov (United States)

    Castrillón, Mario A.; Morero, Damián A.; Agazzi, Oscar E.; Hueda, Mario R.

    2015-08-01

    The joint iterative detection and decoding (JIDD) technique has been proposed by Barbieri et al. (2007) with the objective of compensating the time-varying phase noise and constant frequency offset experienced in satellite communication systems. The application of JIDD to optical coherent receivers in the presence of laser frequency fluctuations has not been reported in prior literature. Laser frequency fluctuations are caused by mechanical vibrations, power supply noise, and other mechanisms. They significantly degrade the performance of the carrier phase estimator in high-speed intradyne coherent optical receivers. This work investigates the performance of the JIDD algorithm in multi-gigabit optical coherent receivers. We present simulation results of bit error rate (BER) for non-differential polarization division multiplexing (PDM)-16QAM modulation in a 200 Gb/s coherent optical system that includes an LDPC code with 20% overhead and net coding gain of 11.3 dB at BER = 10-15. Our study shows that JIDD with a pilot rate ⩽ 5 % compensates for both laser phase noise and laser frequency fluctuation. Furthermore, since JIDD is used with non-differential modulation formats, we find that gains in excess of 1 dB can be achieved over existing solutions based on an explicit carrier phase estimator with differential modulation. The impact of the fiber nonlinearities in dense wavelength division multiplexing (DWDM) systems is also investigated. Our results demonstrate that JIDD is an excellent candidate for application in next generation high-speed optical coherent receivers.

  14. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  15. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  16. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  17. Deformability measurement of red blood cells using a microfluidic channel array and an air cavity in a driving syringe with high throughput and precise detection of subpopulations.

    Science.gov (United States)

    Kang, Yang Jun; Ha, Young-Ran; Lee, Sang-Joon

    2016-01-07

    Red blood cell (RBC) deformability has been considered a potential biomarker for monitoring pathological disorders. High throughput and detection of subpopulations in RBCs are essential in the measurement of RBC deformability. In this paper, we propose a new method to measure RBC deformability by evaluating temporal variations in the average velocity of blood flow and image intensity of successively clogged RBCs in the microfluidic channel array for specific time durations. In addition, to effectively detect differences in subpopulations of RBCs, an air compliance effect is employed by adding an air cavity into a disposable syringe. The syringe was equally filled with a blood sample (V(blood) = 0.3 mL, hematocrit = 50%) and air (V(air) = 0.3 mL). Owing to the air compliance effect, blood flow in the microfluidic device behaved transiently depending on the fluidic resistance in the microfluidic device. Based on the transient behaviors of blood flows, the deformability of RBCs is quantified by evaluating three representative parameters, namely, minimum value of the average velocity of blood flow, clogging index, and delivered blood volume. The proposed method was applied to measure the deformability of blood samples consisting of homogeneous RBCs fixed with four different concentrations of glutaraldehyde solution (0%-0.23%). The proposed method was also employed to evaluate the deformability of blood samples partially mixed with normal RBCs and hardened RBCs. Thereafter, the deformability of RBCs infected by human malaria parasite Plasmodium falciparum was measured. As a result, the three parameters significantly varied, depending on the degree of deformability. In addition, the deformability measurement of blood samples was successfully completed in a short time (∼10 min). Therefore, the proposed method has significant potential in deformability measurement of blood samples containing hematological diseases with high throughput and precise detection of

  18. Study on stair-step liquid triggered capillary valve for microfluidic systems

    Science.gov (United States)

    Zhang, Lei; Jones, Ben; Majeed, Bivragh; Nishiyama, Yukari; Okumura, Yasuaki; Stakenborg, Tim

    2018-06-01

    In lab-on-a-chip systems, various microfluidic technologies are being developed to handle fluids at very small quantities, e.g. in the scale of nano- or pico-liter. To achieve autonomous fluid handling at a low cost, passive fluidic control, based on the capillary force between the liquid and microchannel surface, is of the utmost interest in the microsystem. Valves are an essential component for flow control in many microfluidic systems, which enables a sequence of fluidic operations to be performed. In this paper, we present a new passive valve structure for a capillary driven microfluidic device. It is a variation of a capillary trigger valve that is amenable to silicon microfabrication; it will be referred to as a stair-step liquid triggered valve. In this paper, the valve functionality and its dependencies on channel geometry, surface contact angle, and surface roughness are studied both experimentally and with numerical modeling. The effect of the contact angle was explored in experiments on the silicon microfabricated valve structure; a maximal working contact angle, above which the valve fails to be triggered, was demonstrated. The fluidic behavior in the stair-step channel structure was further explored computationally using the finite volume method with the volume-of-fluid approach. Surface roughness due to scalloping of the sidewall during the Bosch etch process was hypothesized to reduce the sidewall contact angle. The reduced contact angle has considerable impacts on the capillary pressure as the liquid vapor interface traverses the stair-step structure of the valve. An improved match in the maximal working contact angle between the experiments and model was obtained when considering this surface roughness effect.

  19. On the hydrodynamic characterization of a passive Shape Memory Alloy valve

    International Nuclear Information System (INIS)

    Waddell, A.M.; Punch, J.; Stafford, J.; Jeffers, N.

    2015-01-01

    An attractive approach to the thermal management of next generation photonics devices (heat fluxes > 10 2  W/cm 2 ) is micro-channel cooling, and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. In this paper, a NiTi Shape Memory Alloy (SMA) micro-valve design for passive flow control and thermal management was prototyped at the macro scale and hydrodynamically characterized. The dynamic behavior of the valve was observed and the loss coefficient (ζ v ) derived from pressure-flow measurements. The hydrodynamic characterization study is important because ζ v is sensitive to Re and geometry in the flow regime of the micro-fluidic system. Static replicas of the SMA valve geometry were tested for low Re (110–220) and a range of opening ratios (β) in a ø1 mm miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. A correlation was developed to interpolate ζ v from a given Re and β. The valve loss coefficients obtained in this work are important parameters in the modeling and design of future micro-fluidic cooling systems. - Highlights: • A miniature normally closed passive SMA valve for micro-fluidic cooling of Photonics devices is demonstrated in this paper. • The passive dynamic behaviour of the valve in response to temperature change is observed. • The design is hydrodynamically characterized through pressure-flow measurements. • A correlation for head loss across the valve as a function of Re and blockage ratio is presented

  20. Insidious strut fractures in a DeBakey-Surgitool aortic valve prosthesis.

    Science.gov (United States)

    Scott, S M; Sethi, G K; Paulson, D M; Takaro, T

    1978-04-01

    Recent reports of cage wear occurring in DeBakey-Surgitool aortic valve prostheses prompted us to examine with image intensification all our patients who have had this type of prosthesis implanted. One patient, who was asymptomatic, was discovered to have a prosthesis with two fractured struts. This patient's prosthetic valve was replaced successfully with a stented porcine heterograft prosthesis. Including the valve removed from this patient, 8 DeBakey-Surgitool aortic valves with structural defects have been reported to the manufacturer. In the absence of a catastrophic event, patients with valves having fractured or worn struts may be totally asymptomatic, and routine periodic roentgenographic examination may be the only way of detecting strut wear or fracture.

  1. Experimental Study on Fracture Failure of BRW 250 Pump Liquid Valve Mechanical Spring Surface

    Directory of Open Access Journals (Sweden)

    Rui Zeng

    2017-01-01

    Full Text Available In this paper, the singularity analysis method based on the continuous wave for the vibration signal of the plunger pump liquid valve under different conditions was studied, and the LMS based weighted least square method with good robustness and validity was proposed to calculate the LPZ index, which was the judgment criterion for fault of liquid valve mechanical spring. Fault diagnostic test results showed that the method could overcome the singularity of the binary discrete wave in the detection and quantitative accuracy problem, realize the accurate positioning of the singular point in the signal, identify the liquid valve disc in the spring break state to the liquid valve seat or lift limit the impact of the moment, and determine the fault of the liquid valve mechanical spring effectively.

  2. Bypass valve and coolant flow controls for optimum temperatures in waste heat recovery systems

    Science.gov (United States)

    Meisner, Gregory P

    2013-10-08

    Implementing an optimized waste heat recovery system includes calculating a temperature and a rate of change in temperature of a heat exchanger of a waste heat recovery system, and predicting a temperature and a rate of change in temperature of a material flowing through a channel of the waste heat recovery system. Upon determining the rate of change in the temperature of the material is predicted to be higher than the rate of change in the temperature of the heat exchanger, the optimized waste heat recovery system calculates a valve position and timing for the channel that is configurable for achieving a rate of material flow that is determined to produce and maintain a defined threshold temperature of the heat exchanger, and actuates the valve according to the calculated valve position and calculated timing.

  3. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  4. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  5. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  6. Cavitation noise from butterfly valves

    International Nuclear Information System (INIS)

    Rahmeyer, W.J.

    1982-01-01

    Cavitation in valves can produce levels of intense noise. It is possible to mathematically express a limit for a design level of cavitation noise in terms of the cavitation parameter sigma. Using the cavitation parameter or limit, it is then possible to calculate the flow conditions at which a design level of cavitation noise will occur. However, the intensity of cavitation increases with the upstream pressure and valve size at a constant sigma. Therefore, it is necessary to derive equations to correct or scale the cavitation limit for the effects of different upstream pressures and valve sizes. The following paper discusses and presents experimental data for the caviation noise limit as well as the cavitation limits of incipient, critical, incipient damage, and choking cavitation for butterfly valves. The main emphasis is on the design limit of caviation noise, and a noise level of 85 decibels was selected as the noise limit. Tables of data and scaling exponents are included for applying the design limits for the effects of upstream pressure and valve size. (orig.)

  7. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  8. Application of risk-based methods to inservice testing of check valves

    Energy Technology Data Exchange (ETDEWEB)

    Closky, N.B.; Balkey, K.R.; McAllister, W.J. [and others

    1996-12-01

    Research efforts have been underway in the American Society of Mechanical Engineers (ASME) and industry to define appropriate methods for the application of risk-based technology in the development of inservice testing (IST) programs for pumps and valves in nuclear steam supply systems. This paper discusses a pilot application of these methods to the inservice testing of check valves in the emergency core cooling system of Georgia Power`s Vogtle nuclear power station. The results of the probabilistic safety assessment (PSA) are used to divide the check valves into risk-significant and less-risk-significant groups. This information is reviewed by a plant expert panel along with the consideration of appropriate deterministic insights to finally categorize the check valves into more safety-significant and less safety-significant component groups. All of the more safety-significant check valves are further evaluated in detail using a failure modes and causes analysis (FMCA) to assist in defining effective IST strategies. A template has been designed to evaluate how effective current and emerging tests for check valves are in detecting failures or in finding significant conditions that are precursors to failure for the likely failure causes. This information is then used to design and evaluate appropriate IST strategies that consider both the test method and frequency. A few of the less safety-significant check valves are also evaluated using this process since differences exist in check valve design, function, and operating conditions. Appropriate test strategies are selected for each check valve that has been evaluated based on safety and cost considerations. Test strategies are inferred from this information for the other check valves based on similar check valve conditions. Sensitivity studies are performed using the PSA model to arrive at an overall IST program that maintains or enhances safety at the lowest achievable cost.

  9. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  10. Aging effect of spin accumulation in non-local spin valves

    International Nuclear Information System (INIS)

    Zhao, Bing; Zhang, Ziyu; Chen, Xiaobing; Zhang, Xiaohan; Pan, Jiahui; Ma, Jiajun; Li, Juan; Wang, Zhicheng; Wang, Le; Xu, Xiaoguang; Jiang, Yong

    2017-01-01

    Highlights: • First time to reveal the whole temporal evolution life of spintronics devices. • The gradual oxidation of the junctions’ areas and that of the channel are confirmed to be the predominant factors to determine the temporal evolution. • Physically, the temporal evolution can be evaluated by theories of S. Takahashi and A. Fert. • This study may offer some useful advice for the design and protection of future industrial spintronics devices. - Abstract: A temporal evolution of spin accumulation of Co/MgO/Ag spin valves have been studied by using the nonlocal spin detection technique over almost a 3-month period in the ambient environment after the fabrication of the devices. Three different stages of the spin accumulation are first observed due to aging effect. The aging effect comes from two contributions–the gradual oxidation of the Ag/MgO and MgO/Co interfaces at the junctions’ areas which arises from the annealing process and the oxidation of the side surfaces of the Ag channels. The theories of S. Takahashi and A. Fert are introduced to evaluate the different evolution stages of spin accumulation.

  11. Aging effect of spin accumulation in non-local spin valves

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, Bing; Zhang, Ziyu; Chen, Xiaobing; Zhang, Xiaohan; Pan, Jiahui; Ma, Jiajun; Li, Juan; Wang, Zhicheng [State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Wang, Le, E-mail: wangle@ruc.edu.cn [Department of Physics, Renmin University of China, Beijing 100872 (China); Xu, Xiaoguang, E-mail: xgxu@ustb.edu.cn [State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China); Jiang, Yong [State Key Laboratory for Advanced Metals and Materials, School of Materials Science and Engineering, University of Science and Technology Beijing, Beijing 100083 (China)

    2017-06-15

    Highlights: • First time to reveal the whole temporal evolution life of spintronics devices. • The gradual oxidation of the junctions’ areas and that of the channel are confirmed to be the predominant factors to determine the temporal evolution. • Physically, the temporal evolution can be evaluated by theories of S. Takahashi and A. Fert. • This study may offer some useful advice for the design and protection of future industrial spintronics devices. - Abstract: A temporal evolution of spin accumulation of Co/MgO/Ag spin valves have been studied by using the nonlocal spin detection technique over almost a 3-month period in the ambient environment after the fabrication of the devices. Three different stages of the spin accumulation are first observed due to aging effect. The aging effect comes from two contributions–the gradual oxidation of the Ag/MgO and MgO/Co interfaces at the junctions’ areas which arises from the annealing process and the oxidation of the side surfaces of the Ag channels. The theories of S. Takahashi and A. Fert are introduced to evaluate the different evolution stages of spin accumulation.

  12. Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection

    International Nuclear Information System (INIS)

    Brankov, Jovan G

    2013-01-01

    The channelized Hotelling observer (CHO) has become a widely used approach for evaluating medical image quality, acting as a surrogate for human observers in early-stage research on assessment and optimization of imaging devices and algorithms. The CHO is typically used to measure lesion detectability. Its popularity stems from experiments showing that the CHO's detection performance can correlate well with that of human observers. In some cases, CHO performance overestimates human performance; to counteract this effect, an internal-noise model is introduced, which allows the CHO to be tuned to match human-observer performance. Typically, this tuning is achieved using example data obtained from human observers. We argue that this internal-noise tuning step is essentially a model training exercise; therefore, just as in supervised learning, it is essential to test the CHO with an internal-noise model on a set of data that is distinct from that used to tune (train) the model. Furthermore, we argue that, if the CHO is to provide useful insights about new imaging algorithms or devices, the test data should reflect such potential differences from the training data; it is not sufficient simply to use new noise realizations of the same imaging method. Motivated by these considerations, the novelty of this paper is the use of new model selection criteria to evaluate ten established internal-noise models, utilizing four different channel models, in a train-test approach. Though not the focus of the paper, a new internal-noise model is also proposed that outperformed the ten established models in the cases tested. The results, using cardiac perfusion SPECT data, show that the proposed train-test approach is necessary, as judged by the newly proposed model selection criteria, to avoid spurious conclusions. The results also demonstrate that, in some models, the optimal internal-noise parameter is very sensitive to the choice of training data; therefore, these models are prone

  13. Evaluation of the channelized Hotelling observer with an internal-noise model in a train-test paradigm for cardiac SPECT defect detection.

    Science.gov (United States)

    Brankov, Jovan G

    2013-10-21

    The channelized Hotelling observer (CHO) has become a widely used approach for evaluating medical image quality, acting as a surrogate for human observers in early-stage research on assessment and optimization of imaging devices and algorithms. The CHO is typically used to measure lesion detectability. Its popularity stems from experiments showing that the CHO's detection performance can correlate well with that of human observers. In some cases, CHO performance overestimates human performance; to counteract this effect, an internal-noise model is introduced, which allows the CHO to be tuned to match human-observer performance. Typically, this tuning is achieved using example data obtained from human observers. We argue that this internal-noise tuning step is essentially a model training exercise; therefore, just as in supervised learning, it is essential to test the CHO with an internal-noise model on a set of data that is distinct from that used to tune (train) the model. Furthermore, we argue that, if the CHO is to provide useful insights about new imaging algorithms or devices, the test data should reflect such potential differences from the training data; it is not sufficient simply to use new noise realizations of the same imaging method. Motivated by these considerations, the novelty of this paper is the use of new model selection criteria to evaluate ten established internal-noise models, utilizing four different channel models, in a train-test approach. Though not the focus of the paper, a new internal-noise model is also proposed that outperformed the ten established models in the cases tested. The results, using cardiac perfusion SPECT data, show that the proposed train-test approach is necessary, as judged by the newly proposed model selection criteria, to avoid spurious conclusions. The results also demonstrate that, in some models, the optimal internal-noise parameter is very sensitive to the choice of training data; therefore, these models are prone

  14. The development of fusion sensor techniques for condition monitoring of a check valve

    International Nuclear Information System (INIS)

    Seong, S.H.; Kim, J.S.; Hur, S.; Kim, J.T.; Park, W.M.; Cha, D.B.

    2004-01-01

    The failures of check valves are one of the most important problems in nuclear power plants because the reverse flows through the failed check valve impact on the healthy hydraulic loop. The present test method of finding out the mechanical failure of a check valve is very risky in the radiated environments during normal operation. In addition, the detection of failures in the overhaul period is very costly and tedious because many check valves are used in the plants and manual disassembly work is required. We have suggested the fusion sensor technology for detecting the failures of check valves through measuring and analyzing the backward leakage flow and mechanical vibration without disassembling the check valve. The fusion sensor means that more than two sensors are used in order to identify and analyze the changes of the frequency response between the failed check valve and healthy check valve. We use the accelerometer and acoustic emission sensor as an alternative to the fusion sensor methodology. We have found that the acoustic emission sensor would be capable of directly detecting a high frequency acoustic wave generated from backward leakage flow itself at a low pressure and temperature. The accelerometer for detecting the mechanical vibration induced from leakage flows would, also, be useful at a high pressure and temperature from the previous studies. The effectiveness of this system is that it is possible for predictive maintenance and information of the problem valve will be captured and it reduces the radiation exposure for the maintenance personnel during power operation as well as the maintenance period. (orig.)

  15. Micromachined filter-chamber array with passive valves for biochemical assays on beads

    NARCIS (Netherlands)

    Lichtenberg, Jan; Verpoorte, Elisabeth; De Rooij, Nico F.

    2001-01-01

    The filter-chamber array presented here enables a real-time parallel analysis of three different samples on beads in a volume of 3 nL, on a 1 cm2chip. The filter-chamber array is a system containing three filter-chambers, three passive valves at the inlet channels and a common outlet. The design

  16. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  17. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  18. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  19. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  20. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  1. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  2. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  3. Evaluation of mispositioned ECCS valves

    International Nuclear Information System (INIS)

    Hill, R.A.; O'Brien, J.F.; McIntire, D.C.; Barlow, R.T.

    1977-09-01

    In October of 1975, Westinghouse submitted NS-CE-787, dated October 17, 1975, to the Nuclear Regulatory Commission (NRC) and entered into discussions with them concerning the spurious movement of certain motor-operated valves (MOV's) in the Emergency Core Cooling System (ECCS) to a position defeating the ECCS function at a time when this function is required. On November 25, 1975, the discussion turned to the possible movement of a manually controlled, motor-operated valve due to a fault in its electrical circuitry and the NRC staff expressed concerns about other possible failure modes that might lead to such a valve movement. The NRC meeting minutes document these concerns. This report is an item-by-item response to the concerns expressed by the NRC staff at that meeting and incorporates the original electrical fault analysis

  4. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  5. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  6. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  7. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  8. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  9. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  10. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  11. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  12. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  13. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  14. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  15. Knockdown resistance (kdr)-like mutations in the voltage-gated sodium channel of a malaria vector Anopheles stephensi and PCR assays for their detection.

    Science.gov (United States)

    Singh, Om P; Dykes, Cherry L; Lather, Manila; Agrawal, Om P; Adak, Tridibes

    2011-03-14

    Knockdown resistance (kdr) in insects, resulting from mutation(s) in the voltage-gated sodium channel (vgsc) gene is one of the mechanisms of resistance against DDT and pyrethroid-group of insecticides. The most common mutation(s) associated with knockdown resistance in insects, including anophelines, has been reported to be present at residue Leu1014 in the IIS6 transmembrane segment of the vgsc gene. This study reports the presence of two alternative kdr-like mutations, L1014S and L1014F, at this residue in a major malaria vector Anopheles stephensi and describes new PCR assays for their detection. Part of the vgsc (IIS4-S5 linker-to-IIS6 transmembrane segment) of An. stephensi collected from Alwar (Rajasthan, India) was PCR-amplified from genomic DNA, sequenced and analysed for the presence of deduced amino acid substitution(s). Analysis of DNA sequences revealed the presence of two alternative non-synonymous point mutations at L1014 residue in the IIS6 transmembrane segment of vgsc, i.e., T>C mutation on the second position and A>T mutation on the third position of the codon, leading to Leu (TTA)-to-Ser (TCA) and -Phe (TTT) amino acid substitutions, respectively. Polymerase chain reaction (PCR) assays were developed for identification of each of these two point mutations. Genotyping of An. stephensi mosquitoes from Alwar by PCR assays revealed the presence of both mutations, with a high frequency of L1014S. The PCR assays developed for detection of the kdr mutations were specific as confirmed by DNA sequencing of PCR-genotyped samples. Two alternative kdr-like mutations, L1014S and L1014F, were detected in An. stephensi with a high allelic frequency of L1014S. The occurrence of L1014S is being reported for the first time in An. stephensi. Two specific PCR assays were developed for detection of two kdr-like mutations in An. stephensi.

  16. Detection of gear cracks in a complex gearbox of wind turbines using supervised bounded component analysis of vibration signals collected from multi-channel sensors

    Science.gov (United States)

    Li, Zhixiong; Yan, Xinping; Wang, Xuping; Peng, Zhongxiao

    2016-06-01

    In the complex gear transmission systems, in wind turbines a crack is one of the most common failure modes and can be fatal to the wind turbine power systems. A single sensor may suffer with issues relating to its installation position and direction, resulting in the collection of weak dynamic responses of the cracked gear. A multi-channel sensor system is hence applied in the signal acquisition and the blind source separation (BSS) technologies are employed to optimally process the information collected from multiple sensors. However, literature review finds that most of the BSS based fault detectors did not address the dependence/correlation between different moving components in the gear systems; particularly, the popular used independent component analysis (ICA) assumes mutual independence of different vibration sources. The fault detection performance may be significantly influenced by the dependence/correlation between vibration sources. In order to address this issue, this paper presents a new method based on the supervised order tracking bounded component analysis (SOTBCA) for gear crack detection in wind turbines. The bounded component analysis (BCA) is a state of art technology for dependent source separation and is applied limitedly to communication signals. To make it applicable for vibration analysis, in this work, the order tracking has been appropriately incorporated into the BCA framework to eliminate the noise and disturbance signal components. Then an autoregressive (AR) model built with prior knowledge about the crack fault is employed to supervise the reconstruction of the crack vibration source signature. The SOTBCA only outputs one source signal that has the closest distance with the AR model. Owing to the dependence tolerance ability of the BCA framework, interfering vibration sources that are dependent/correlated with the crack vibration source could be recognized by the SOTBCA, and hence, only useful fault information could be preserved in

  17. Velocity measurements and flow patterns within the hinge region of a Medtronic Parallel bileaflet mechanical valve with clear housing.

    Science.gov (United States)

    Ellis, J T; Healy, T M; Fontaine, A A; Saxena, R; Yoganathan, A P

    1996-11-01

    During recent clinical trials the Medtronic Parallel bileaflet mechanical heart valve was found to have an unacceptable number of valves with thrombus formation when implanted in the mitral position. Thrombi were observed in the hinge region and also in the upstream portion of the valve housing in the vicinity of the hinge. It was hypothesized that the flow conditions inside the hinge may have contributed to the thrombus formation. In order to investigate the flow structures within the hinge, laser Doppler anemometry (LDA) measurements were conducted in both steady and pulsatile flow at approximately 70 predetermined sites within the hinge region of a 27 mm Medtronic Parallel mitral valve with transparent housing. The pulsatile flow velocity measurements were animated in time using a graphical software package to visualize the hinge flow field throughout the cardiac cycle. The LDA measurements revealed that mean forward flow velocities through the hinge region were on the order of 0.10-0.20 m/s. In the inflow channel, a large vortical structure was present during diastole. Upon valve closure, peak reverse velocity reached 3 m/s close to the housing wall in the inflow channel. This area also experienced high turbulent shear stresses (> 6000 dynes/cm2) during the leakage flow phase. A disturbed, vortical flow was again present in the inflow channel after valve closure, while slightly above the leaflet peg and relief the flow was essentially stagnant. The high turbulent stresses near the top of the inflow channel, combined with a persistent vortex, implicate the inflow channel of the hinge as a likely region of thrombus formation. This experimental investigation revealed zones of flow stagnation in the inflow region of the hinge throughout the cardiac cycle and elevated turbulent shear stress levels in the inflow region during the leakage flow phase. These fluid mechanic phenomena are most likely a direct result of the complex geometry of the hinge of this valve

  18. 49 CFR 195.260 - Valves: Location.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: Location. 195.260 Section 195.260... PIPELINE Construction § 195.260 Valves: Location. A valve must be installed at each of the following locations: (a) On the suction end and the discharge end of a pump station in a manner that permits isolation...

  19. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  20. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  1. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  2. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a...

  3. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  4. Valve Corporation: Strategy Tipping Points and Thresholds

    OpenAIRE

    Teppo Felin

    2015-01-01

    Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012).  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  5. Valve Corporation: Strategy Tipping Points and Thresholds

    Directory of Open Access Journals (Sweden)

    Teppo Felin

    2015-06-01

    Full Text Available Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012.  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  6. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  7. Sequential transcatheter aortic valve implantation due to valve dislodgement

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected...

  8. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  9. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  10. In vitro 2D PIV measurements and related aperture areas of tricuspid bioprosthetic mitral valves at the beginning of diastole.

    Science.gov (United States)

    Bazan, Ovandir; Ortiz, Jayme Pinto; Fukumasu, Newton Kiyoshi; Pacifico, Antonio Luiz; Yanagihara, Jurandir Itizo

    2016-07-04

    Besides ventricular parameters, the design and angular orientation of a prosthetic heart valve induce a specific flow field. The aim of this study was to know the inflow characteristics of a left ventricular model (LVM), investigating the behavior of tricuspid bioprosthetic mitral valves in terms of velocity profiles and related valve aperture areas at the beginning of diastole, under different conditions. 3 heart rates (HRs) were established in the LVM and each mitral bioprosthesis (27 and 31 mm diameter) was installed in 2 orientations, rotated by 180° . For each experimental setup, 2-dimensional particle image velocimetry (2D PIV) measurements and simultaneous mitral valve (MV) area detection were obtained from 50 samples. The results from the velocity profiles immediately downstream of mitral bioprostheses showed the influence of valve orientation for moderate HRs, although for a similar magnitude of mean velocity vectors. The geometries of MV open areas for each HR were similar regardless of valve orientation, except for the 27-mm valve at 90 beats per minute (bpm), and for the 31-mm valve at 60 bpm. Moreover, for each HR, similar percentages of valve open area were obtained regardless of MV nominal diameters. In conclusion, the experimental setup for the 2D PIV measurements synchronized with the MV area detection was a useful tool for knowing the inflow characteristics of the LVM.

  11. Spin filter effect of hBN/Co detector electrodes in a 3D topological insulator spin valve

    Science.gov (United States)

    Vaklinova, Kristina; Polyudov, Katharina; Burghard, Marko; Kern, Klaus

    2018-03-01

    Topological insulators emerge as promising components of spintronic devices, in particular for applications where all-electrical spin control is essential. While the capability of these materials to generate spin-polarized currents is well established, only very little is known about the spin injection/extraction into/out of them. Here, we explore the switching behavior of lateral spin valves comprising the 3D topological insulator Bi2Te2Se as channel, which is separated from ferromagnetic Cobalt detector contacts by an ultrathin hexagonal boron nitride (hBN) tunnel barrier. The corresponding contact resistance displays a notable variation, which is correlated with a change of the switching characteristics of the spin valve. For contact resistances below ~5 kΩ, the hysteresis in the switching curve reverses upon reversing the applied current, as expected for spin-polarized currents carried by the helical surface states. By contrast, for higher contact resistances an opposite polarity of the hysteresis loop is observed, which is independent of the current direction, a behavior signifying negative spin detection efficiency of the multilayer hBN/Co contacts combined with bias-induced spin signal inversion. Our findings suggest the possibility to tune the spin exchange across the interface between a ferromagnetic metal and a topological insulator through the number of intervening hBN layers.

  12. Cine MR imaging in mitral valve prolapse

    International Nuclear Information System (INIS)

    Kumai, Toshihiko

    1993-01-01

    This study was undertaken to assess the ability of cine MR imaging to evaluate the direction, timing, and severity of mitral regurgitation in patients with mitral valve prolapse (MVP). The population of this study was 33 patients with MVP diagnosed by two-dimensional echocardiography and 10 patients with rheumatic mitral valve disease (MSR) for comparison. 7 patients with MVP and 5 with MSR had atrial fibrillation and/or history of congestive heart failure as complications. Mitral regurgitation was graded for severity by color Doppler flow imaging in all patients. Direction and size of systolic flow void in the left atrium were analyzed by contiguous multilevel cine MR images and the maximum volumes of flow void and left atrium were measured. Although flow void was found at the center of the left atrium in most of MSR, it was often directed along the postero-caudal atrial wall in anterior leaflet prolapse and along the anterocranial atrial wall in posterior leaflet prolapse. In MVP, the maximum volume of flow void was often seen in late systole. The maximum volume of flow void and that of left atrium were significantly larger in patients with atrial fibrillation and/or history of congestive heart failure. The length and volume of flow void were increased with clinical severity and degree of regurgitation determined by color Doppler flow imaging. Thus cine MR imaging provides a useful means for detection and semiquantitative evaluation of mitral regurgitation in subjects with MVP. (author)

  13. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. CANDU channel flow verification

    International Nuclear Information System (INIS)

    Mazalu, N.; Negut, Gh.

    1997-01-01

    The purpose of this evaluation was to obtain accurate information on each channel flow that enables us to assess precisely the level of reactor thermal power and, for reasons of safety, to establish which channel is boiling. In order to assess the channel flow parameters, computer simulations were done with the NUCIRC code and the results were checked by measurements. The complete channel flow measurements were made in the zero power cold condition. In hot conditions there were made flow measurements using the Shut Down System 1 (SDS 1) flow devices from 0.1 % F.P. up to 100 % F.P. The NUCIRC prediction for CANDU channel flows and the measurements by Ultrasonic Flow Meter at zero power cold conditions and SDS 1 flow channel measurements at different reactor power levels showed an acceptable agreement. The 100 % F.P. average errors for channel flow of R, shows that suitable NUCIRC flow assessment can be made. So, it can be done a fair prediction of the reactor power distribution. NUCIRC can predict accurately the onset of boiling and helps to warn at the possible power instabilities at high powers or it can detect the flow blockages. The thermal hydraulic analyst has in NUCIRC a suitable tool to do accurate predictions for the thermal hydraulic parameters for different steady state power levels which subsequently leads to an optimal CANDU reactor operation. (authors)

  15. Ion channeling

    International Nuclear Information System (INIS)

    Erramli, H.; Blondiaux, G.

    1994-01-01

    Channeling phenomenon was predicted, many years ago, by stark. The first channeling experiments were performed in 1963 by Davies and his coworkers. Parallely Robinson and Oen have investigated this process by simulating trajectories of ions in monocrystals. This technique has been combined with many methods like Rutherford Backscattering Spectrometry (R.B.S.), Particles Induced X-rays Emission (P.I.X.E) and online Nuclear Reaction (N.R.A.) to localize trace elements in the crystal or to determine crystalline quality. To use channeling for material characterization we need data about the stopping power of the incident particle in the channeled direction. The ratios of channeled to random stopping powers of silicon for irradiation in the direction have been investigated and compared to the available theoretical results. We describe few applications of ion channeling in the field of materials characterization. Special attention is given to ion channeling combined with Charged Particle Activation Analysis (C.P.A.A.) for studying the behaviour of oxygen atoms in Czochralski silicon lattices under the influence of internal gettering and in different gaseous atmospheres. Association between ion channeling and C.P.A.A was also utilised for studying the influence of the growing conditions on concentration and position of carbon atoms at trace levels in the MOVPE Ga sub (1-x) Al sub x lattice. 6 figs., 1 tab., 32 refs. (author)

  16. Sensing with Ion Channels

    CERN Document Server

    Martinac, Boris

    2008-01-01

    All living cells are able to detect and translate environmental stimuli into biologically meaningful signals. Sensations of touch, hearing, sight, taste, smell or pain are essential to the survival of all living organisms. The importance of sensory input for the existence of life thus justifies the effort made to understand its molecular origins. Sensing with Ion Channels focuses on ion channels as key molecules enabling biological systems to sense and process the physical and chemical stimuli that act upon cells in their living environment. Its aim is to serve as a reference to ion channel specialists and as a source of new information to non specialists who want to learn about the structural and functional diversity of ion channels and their role in sensory physiology.

  17. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  18. Spring valve for well completion

    Energy Technology Data Exchange (ETDEWEB)

    Gorbatov, P T

    1966-07-22

    A spring-loaded valve for well completion consists of a housing with a spring-loaded closing element. In order to protect the closing element from corrosion which might lower the pressure drop, the closing element is made in the form of a piston. It is tightly connected with sealing elements. The housing has orifices, overlapping the piston in the initial position.

  19. Hydraulic servo control spool valve

    Science.gov (United States)

    Miller, Donald M.

    1983-01-01

    A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.

  20. Complete Resolution of a Large Bicuspid Aortic Valve Thrombus with Anticoagulation in Primary Antiphospholipid Syndrome

    Directory of Open Access Journals (Sweden)

    Rayan Jo Rachwan

    2017-09-01

    Full Text Available Native aortic valve thrombosis in primary antiphospholipid syndrome (APLS is a rare entity. We describe a 38-year-old man who presented with neurological symptoms and a cardiac murmur. Transthoracic echocardiography detected a large bicuspid aortic valve thrombus. Laboratory evaluation showed the presence of antiphospholipid antibodies. Anticoagulation was started, and serial echocardiographic studies showed complete resolution of the aortic valve vegetation after 4 months. The patient improved clinically and had no residual symptoms. This report and review of the literature suggests that vegetations in APLS can be treated successfully with conservative treatment, regardless of their size.

  1. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  2. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  3. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  4. Fast leak in channel H9

    International Nuclear Information System (INIS)

    Bauer, E.

    1987-01-01

    The loss of seal of the H9 channel in vacuum, freeing the entire cross section of the front part, leads to a fast leak that progresses rapidly. The effect of depressurizing the reflector can leads to shutdown of the shutdown rod pumps. The source changer associated with the channel fills completely before the valve closes. All of the leak water remains contained within the source changer containment. After the valves open, cooling of the fuel element is handled by natural convection, requiring a reversal of the flow between the plates. This changeover, which takes place at a relatively low pressure level, could lead to local boiling in the fuel element. Consequently, irreversible transformations cannot be excluded as possibilities for the fuel element and even for the control rod. Subsequently, the can is refilled with heavy water with establishment of the usual pressure levels

  5. Condition monitoring of a check valve for nuclear power plants by means of acoustic emission technique

    International Nuclear Information System (INIS)

    Lee, M. R.; Lee, J. H.; Kim, J. T.; Kim, J. S.; Luk, V. K.

    2003-01-01

    This work performed in support of the International Nuclear Energy Research Institute (INERI) program, which was to develop and demonstrate advanced sensor and computational technology for on-line monitoring of the condition of components, structures, and systems in advanced and next-generation nuclear power plants (NPPs). This primary object of this work is to investigate advanced condition monitoring systems based on acoustic emission detection that can provide timely detection of check valve degeneration and service aging so that maintenance/replacement could be preformed prior to loss safety function. The research is focused on the capability of AE technique to provide diagnostic information useful in determining check valve aging and degradation check valve failure and undesirable operating modes. This work also includes the investigation and adaptation of several advanced sensor technologies such as accelerometer and advanced ultrasonic technique. In addition, this work will develop advanced sophisticated signal processing, noise reduction, and pattern recognition techniques and algorithms from check valve degradation.

  6. Acute Mitral Valve Dysfunction Due to Escape of Prosthetic Mechanical Leaflet and Peripheral Leaftlet Embolization.

    Science.gov (United States)

    Calik, Eyup Serhat; Limandal, Husnu Kamil; Arslan, Umit; Tort, Mehmet; Yildiz, Ziya; Bayram, Ednan; Dag, Ozgur; Kaygin, Mehmet Ali; Erkut, Bilgehan

    2015-12-14

    Leaflet escape of prosthetic valve is rare but potentially life threatening. Early diagnosis is essential on account of avoiding mortality, and emergency surgical correction is compulsory. This complication has previously been reported for both monoleaflet and bileaflet valve models. A 30-year-old man who had undergone mitral valve replacement with a bileaflet valve 8 years prior at another center was admitted with acute-onset with cardiogenic shock as an emergency case. Transthoracic echocardiograms showed acute-starting severe mitral regurgitation associated with prosthetic mitral valve. There was a suspicious finding of a single prosthetic mitral leaflet. But the problem related with the valve wasn't specifically determined. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. There was no tissue impingement and thrombosis, one of the two leaflets was absent, and there were no signs of endocarditis or pannus formation in the prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet during surgery. The damaged valve was removed and a replacement 29 mm bileaflet mechanical valve was inserted by right lateral thoracotomy. After post-operative week one, the abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the left femoral artery. Fifteen days after the surgery the escaped leaflet was removed safely from the left femoral artery and the patient made a complete recovery. The escaped leaflet showed a fracture of one of the pivot systems caused by structural failure. Early cardiac surgery should be applied because of life-threatening problems.

  7. Transapical aortic valve implantation without angiography: proof of concept.

    Science.gov (United States)

    Ferrari, Enrico; Sulzer, Christopher; Marcucci, Carlo; Rizzo, Elena; Tozzi, Piergiorgio; von Segesser, Ludwig K

    2010-06-01

    Cardiac computed tomographic scans, coronary angiograms, and aortographies are routinely performed in transcatheter heart valve therapies. Consequently, all patients are exposed to multiple contrast injections with a following risk of nephrotoxicity and postoperative renal failure. The transapical aortic valve implantation without angiography can prevent contrast-related complications. Between November 2008 and November 2009, 30 consecutive high-risk patients (16 female, 53.3%) underwent transapical aortic valve implantation without angiography. The landmarks identification, the stent-valve positioning, and the postoperative control were routinely performed under transesophageal echocardiogram and fluoroscopic visualization without contrast injections. Mean age was 80.1 +/- 8.7 years. Mean valve gradient, aortic orifice area, and ejection fraction were 60.3 +/- 20.9 mm Hg, 0.7 +/- 0.16 cm(2), and 0.526 +/- 0.128, respectively. Risk factors were pulmonary hypertension (60%), peripheral vascular disease (70%), chronic pulmonary disease (50%), previous cardiac surgery (13.3%), and chronic renal insufficiency (40%) (mean blood creatinine and urea levels: 96.8 +/- 54 microg/dL and 8.45 +/- 5.15 mmol/L). Average European System for Cardiac Operative Risk Evaluation was 32.2 +/- 13.3%. Valve deployment in the ideal landing zone was 96.7% successful and valve embolization occurred once. Thirty-day mortality was 10% (3 patients). Causes of death were the following: intraoperative ventricular rupture (conversion to sternotomy), right ventricular failure, and bilateral pneumonia. Stroke occurred in one patient at postoperative day 9. Renal failure (postoperative mean blood creatinine and urea levels: 91.1 +/- 66.8 microg/dL and 7.27 +/- 3.45 mmol/L), myocardial infarction, and atrioventricular block were not detected. Transapical aortic valve implantation without angiography requires a short learning curve and can be performed routinely by experienced teams. Our report

  8. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  9. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  10. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Channel box

    International Nuclear Information System (INIS)

    Tanabe, Akira.

    1993-01-01

    In a channel box of a BWR type reactor, protruding pads are disposed in axial position on the lateral side of a channel box opposing to a control rod and facing the outer side portion of the control rod in a reactor core loaded state. In the initial loading stage of fuel assemblies, channel fasteners and spacer pads are abutted against each other in the upper portion between the channel boxes sandwiching the control rod therebetween. Further, in the lower portion, a gap as a channel for the movement of the control rod is ensured by the support of fuel support metals. If the channel box is bent toward the control rod along with reactor operation, the pads are abutted against each other to always ensure the gap through which the control rod can move easily. Further, when the pads are brought into contact with each other, the bending deformation of the channel box is corrected by urging to each other. Thus, the control rod can always be moved smoothly to attain reactor safety operation. (N.H.)

  12. The effect of postoperative medical treatment on left ventricular mass regression after aortic valve replacement.

    Science.gov (United States)

    Helder, Meghana R K; Ugur, Murat; Bavaria, Joseph E; Kshettry, Vibhu R; Groh, Mark A; Petracek, Michael R; Jones, Kent W; Suri, Rakesh M; Schaff, Hartzell V

    2015-03-01

    The study objective was to analyze factors associated with left ventricular mass regression in patients undergoing aortic valve replacement with a newer bioprosthesis, the Trifecta valve pericardial bioprosthesis (St Jude Medical Inc, St Paul, Minn). A total of 444 patients underwent aortic valve replacement with the Trifecta bioprosthesis from 2007 to 2009 at 6 US institutions. The clinical and echocardiographic data of 200 of these patients who had left ventricular hypertrophy and follow-up studies 1 year postoperatively were reviewed and compared to analyze factors affecting left ventricular mass regression. Mean (standard deviation) age of the 200 study patients was 73 (9) years, 66% were men, and 92% had pure or predominant aortic valve stenosis. Complete left ventricular mass regression was observed in 102 patients (51%) by 1 year postoperatively. In univariate analysis, male sex, implantation of larger valves, larger left ventricular end-diastolic volume, and beta-blocker or calcium-channel blocker treatment at dismissal were significantly associated with complete mass regression. In the multivariate model, odds ratios (95% confidence intervals) indicated that male sex (3.38 [1.39-8.26]) and beta-blocker or calcium-channel blocker treatment at dismissal (3.41 [1.40-8.34]) were associated with increased probability of complete left ventricular mass regression. Patients with higher preoperative systolic blood pressure were less likely to have complete left ventricular mass regression (0.98 [0.97-0.99]). Among patients with left ventricular hypertrophy, postoperative treatment with beta-blockers or calcium-channel blockers may enhance mass regression. This highlights the need for close medical follow-up after operation. Labeled valve size was not predictive of left ventricular mass regression. Copyright © 2015 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  13. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  14. Active and Precise Control of Microdroplet Division Using Horizontal Pneumatic Valves in Bifurcating Microchannel

    Directory of Open Access Journals (Sweden)

    Shuichi Shoji

    2013-05-01

    Full Text Available This paper presents a microfluidic system for the active and precise control of microdroplet division in a micro device. Using two horizontal pneumatic valves formed at downstream of bifurcating microchannel, flow resistances of downstream channels were variably controlled. With the resistance control, volumetric ratio of downstream flows was changed and water-in-oil microdroplets were divided into two daughter droplets of different volume corresponding to the ratio. The microfluidic channels and pneumatic valves were fabricated by single-step soft lithography process of PDMS (polydimethylsiloxane using SU-8 mold. A wide range control of the daughter droplets’ volume ratio was achieved by the simple channel structure. Volumetric ratio between large and small daughter droplets are ranged from 1 to 70, and the smallest droplet volume of 14 pL was obtained. The proposed microfluidic device is applicable for precise and high throughput droplet based digital synthesis.

  15. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  16. The Actuator Fault Diagnosis Based on the Valve Friction

    Directory of Open Access Journals (Sweden)

    Jiajiang Li

    2014-08-01

    Full Text Available Control valve (actuator is the frequently moving terminal Instrument of the control system. To avoid the leaking of the actuator, there is packing at the moving parts. However, the friction caused by the packing can do harm to the control of the system. The washing effect of the media, high temperature, high pressure, frequent movement and other effects can result in the leaking of the packing and the deformation of the valve stem, which causes the change of the friction. The study of the control of the friction has always been an interesting topic in the industry. In this paper, we theoretically analyze the relationship of the friction of the packing and the static performance of the control valve, and offer a method to check the quality of the moving parts by attaching a strain gage (strain rosette to the empty part of the valve stem. This method has been demonstrated via experiment and a method to do error detection is provided at last.

  17. Radiotherapy-induced aortic valve disease associated with porcelain aorta

    International Nuclear Information System (INIS)

    Daitoku, Kazuyuki; Fukui, Kozo; Ichinoseki, Ikkoh; Munakata, Mamoru; Takahashi, Shoichi; Fukuda Ikuo

    2004-01-01

    Mediastinal irradiation has been reported to induce cardiac disease such as pericarditis, valvular dysfunction, conduction abnormalities, accelerated arteriosclerosis of the coronary arteries, and also calcifications of the ascending aorta. We herein describe a case of radiotherapy-induced porcelain aorta and aortic valve disease and their surgical treatment. The patient was diagnosed with myasthenia gravis (MG) in 1965 (Osserman's type II), and mediastinal irradiation was performed in 1970 for treatment of thymic tumor associated with MG. Thirty years after radiation therapy, complete atrioventricular block and aortic valve disease with severe calcification of the ascending aorta and aortic arch (porcelain aorta) were detected on echo cardiogram and cardiac catheterization. A permanent pacemaker was implanted via the left subclavian vein and aortic valve replacement was performed under extracorporeal circulation established by selective cerebral perfusion and balloon occlusion instead of aortic cross-clamping. As no risk factors of arteriosclerosis such as hypercholesterolemia, hyperglycemia and hypertension were apparent, we concluded that the aortic valve disease and porcelain aorta were primarily induced by radiotherapy. (author)

  18. Application of diagnostics to determine motor operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  19. Experimental research and numerical simulation on flow resistance of integrated valve

    International Nuclear Information System (INIS)

    Cai Wei; Bo Hanliang; Qin Benke

    2008-01-01

    The flow resistance of the integrated valve is one of the key parameters for the design of the control rod hydraulic drive system (CRHDS). Experimental research on the improved new integrated valve was performed, and the key data such as pressure difference, volume flow, resistance coefficient and flow coefficient of each flow channel were obtained. With the computational fluid dynamics software CFX, numerical simulation was executed to analyze the effect of Re on the flow resistance. On the basis of experimental and numerical results, fitting empirical formulas of resistance coefficient were obtained, which provide experimental and theoretical foundations for CRHDS's optimized design and theoretical analysis. (authors)

  20. Surface channeling

    International Nuclear Information System (INIS)

    Sizmann, R.; Varelas, C.

    1976-01-01

    There is experimental evidence that swift light ions incident at small angles towards single crystalline surfaces can lose an appreciable fraction of their kinetic energy during reflection. It is shown that these projectiles penetrate into the bulk surface region of the crystal. They can travel as channeled particles along long paths through the solid (surface channeling). The angular distribution and the depth history of the re-emerged projectiles are investigated by computer simulations. A considerable fraction of the penetrating projectiles re-emerges from the crystal with constant transverse energy if the angle of incidence is smaller than the critical angle for axial channeling. Analytical formulae are derived based on a diffusion model for surface channeling. A comparison with experimental data exhibits the relevance of the analytical solutions. (Auth.)