WorldWideScience

Sample records for valve technology compilation

  1. Compiler Technology for Parallel Scientific Computation

    Directory of Open Access Journals (Sweden)

    Can Özturan

    1994-01-01

    Full Text Available There is a need for compiler technology that, given the source program, will generate efficient parallel codes for different architectures with minimal user involvement. Parallel computation is becoming indispensable in solving large-scale problems in science and engineering. Yet, the use of parallel computation is limited by the high costs of developing the needed software. To overcome this difficulty we advocate a comprehensive approach to the development of scalable architecture-independent software for scientific computation based on our experience with equational programming language (EPL. Our approach is based on a program decomposition, parallel code synthesis, and run-time support for parallel scientific computation. The program decomposition is guided by the source program annotations provided by the user. The synthesis of parallel code is based on configurations that describe the overall computation as a set of interacting components. Run-time support is provided by the compiler-generated code that redistributes computation and data during object program execution. The generated parallel code is optimized using techniques of data alignment, operator placement, wavefront determination, and memory optimization. In this article we discuss annotations, configurations, parallel code generation, and run-time support suitable for parallel programs written in the functional parallel programming language EPL and in Fortran.

  2. Compilation of Existing Neutron Screen Technology

    Directory of Open Access Journals (Sweden)

    N. Chrysanthopoulou

    2014-01-01

    Full Text Available The presence of fast neutron spectra in new reactors is expected to induce a strong impact on the contained materials, including structural materials, nuclear fuels, neutron reflecting materials, and tritium breeding materials. Therefore, introduction of these reactors into operation will require extensive testing of their components, which must be performed under neutronic conditions representative of those expected to prevail inside the reactor cores when in operation. Due to limited availability of fast reactors, testing of future reactor materials will mostly take place in water cooled material test reactors (MTRs by tailoring the neutron spectrum via neutron screens. The latter rely on the utilization of materials capable of absorbing neutrons at specific energy. A large but fragmented experience is available on that topic. In this work a comprehensive compilation of the existing neutron screen technology is attempted, focusing on neutron screens developed in order to locally enhance the fast over thermal neutron flux ratio in a reactor core.

  3. Fiscal 2000 report on advanced parallelized compiler technology. Outlines; 2000 nendo advanced heiretsuka compiler gijutsu hokokusho (Gaiyo hen)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    Research and development was carried out concerning the automatic parallelized compiler technology which improves on the practical performance, cost/performance ratio, and ease of operation of the multiprocessor system now used for constructing supercomputers and expected to provide a fundamental architecture for microprocessors for the 21st century. Efforts were made to develop an automatic multigrain parallelization technology for extracting multigrain as parallelized from a program and for making full use of the same and a parallelizing tuning technology for accelerating parallelization by feeding back to the compiler the dynamic information and user knowledge to be acquired during execution. Moreover, a benchmark program was selected and studies were made to set execution rules and evaluation indexes for the establishment of technologies for subjectively evaluating the performance of parallelizing compilers for the existing commercial parallel processing computers, which was achieved through the implementation and evaluation of the 'Advanced parallelizing compiler technology research and development project.' (NEDO)

  4. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  5. Space Shuttle OMS engine valve technology. [Orbital Maneuvering System

    Science.gov (United States)

    Wichmann, H.

    1974-01-01

    Valve technology program to determine shutoff valve concepts suitable for the Orbital Maneuvering System (OMS) engine of the Space Shuttle. The tradeoff studies selected the electric torque motor operated dual poppet and ball valves as the most desirable valve concepts for the OMS Engine Shutoff Valve. A prototype of one of these concepts was built and subjected to a design verification program. A number of unique features were designed to include the required contamination insensitivity, operating fluid compatibility, decontamination capability, minimum maintenance requirement and long service life capability.

  6. Fiscal 1998 research report on super compiler technology; 1998 nendo super konpaira technology no chosa kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    For next-generation super computing systems, research was made on parallel and distributed compiler technology for enhancing an effective performance, and concerned software and architectures for enhancing a performance in coordination with compilers. As for parallel compiler technology, the researches of scalable automated parallel compiler technology, parallel tuning tools, and an operating system to use multi-processor resources effectively are pointed out to be important as concrete technical development issues. In addition, by developing these research results to the architecture technology of single-chip multi-processors, the possibility of development and expansion of the PC, WS and HPC (high-performance computer) markets, and creation of new industries is pointed out. Although wide-area distributed computing is being watched as next-generation computing industry, concrete industrial fields using such computing are now not clear, staying in the groping research stage. (NEDO)

  7. Leaflet escape in a new bileaflet mechanical valve: TRI technologies.

    Science.gov (United States)

    Bottio, Tomaso; Casarotto, Dino; Thiene, Gaetano; Caprili, Luca; Angelini, Annalisa; Gerosa, Gino

    2003-05-13

    Leaflet escape is a mode of structural valve failure for mechanical prostheses. This complication previously has been reported for both monoleaflet and bileaflet valve models. We report 2 leaflet escape occurrences observed in 2 patients who underwent valve replacement with a TRI Technologies valve prosthesis. At the University of Padua, between November 2000 and February 2002, 36 TRI Technologies valve prostheses (26 aortic and 10 mitral) were implanted in 34 patients (12 women and 22 men) with a mean age of 59.9+/-10.3 years (range, 30 to 75 years). There were 5 deaths: 3 in hospital, 1 early after discharge, and 1 late. Two patients experienced a catastrophic prosthetic leaflet escape; the first patient was a 52-year-old man who died 10 days after aortic valve and ascending aorta replacement, and the second was a 58-year-old man who underwent a successful emergency reoperation 20 months after mitral valve replacement. Examination of the explanted prostheses showed in both cases a leaflet escape caused by a leaflet's pivoting system fracture. Prophylactic replacement was then successfully accomplished so far in 12 patients, without evidence of structural valve failure in any of them. Among other significant postoperative complications, we observed 3 major thromboembolisms, 1 hemorrhage, and 1 paravalvular leak. These catastrophes prompted us to interrupt the implantation program, and they cast a shadow on the durability of the TRI Technologies valve prosthesis because of its high risk of structural failure.

  8. Dielectric elastomer actuators used for pneumatic valve technology

    International Nuclear Information System (INIS)

    Giousouf, Metin; Kovacs, Gabor

    2013-01-01

    Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications. (paper)

  9. A review of digital radiography technology for valve inspection

    International Nuclear Information System (INIS)

    Stoev, K.; Guerout, F.M.; Horn, D.

    2008-01-01

    There are thousands of valves in a nuclear power plant (NPP) used for control, safety and checks in various plant systems, so there is a well-identified need for fast and reliable inspection and diagnostics of valves. Digital radiography can provide considerable improvements to the inspection and testing procedures for valves in comparison to classical film radiography. These improvements can lead to significant financial advantages by providing real-time inspection results, significantly reduced inspection and decision-making time, and reduced operational cost. Digital image processing, including digital image enhancement, digital archiving, and digital communication of the images and the results, is also a considerable advantage over classical film radiography technology. Another advantage of digital radiography technology is the improved safety and the reduced environmental impact due to reduced exposure/test times, use of smaller exclusion zones, elimination of chemical processing, and absence of disposable materials. This paper reviews the existing technology and evaluates the potential of digital radiography for inspection and diagnostics of valves. Station needs and requirements are assessed, and the safety, environmental and economical constraints of digital radiography techniques estimated. The advantages and disadvantages of different digital radiography equipment are compared, and their limitations and characteristics studied. (author)

  10. Learning curve analysis of mitral valve repair using telemanipulative technology.

    Science.gov (United States)

    Charland, Patrick J; Robbins, Tom; Rodriguez, Evilio; Nifong, Wiley L; Chitwood, Randolph W

    2011-08-01

    To determine if the time required to perform mitral valve repairs using telemanipulation technology decreases with experience and how that decrease is influenced by patient and procedure variables. A single-center retrospective review was conducted using perioperative and outcomes data collected contemporaneously on 458 mitral valve repair surgeries using telemanipulative technology. A regression model was constructed to assess learning with this technology and predict total robot time using multiple predictive variables. Statistical analysis was used to determine if models were significantly useful, to rule out correlation between predictor variables, and to identify terms that did not contribute to the prediction of total robot time. We found a statistically significant learning curve (P learning percentage∗ derived from total robot times† for the first 458 recorded cases of mitral valve repair using telemanipulative technology is 95% (R(2) = .40). More than one third of the variability in total robot time can be explained through our model using the following variables: type of repair (chordal procedures, ablations, and leaflet resections), band size, use of clips alone in band implantation, and the presence of a fellow at bedside (P Learning in mitral valve repair surgery using telemanipulative technology occurs at the East Carolina Heart Institute according to a logarithmic curve, with a learning percentage of 95%. From our regression output, we can make an approximate prediction of total robot time using an additive model. These metrics can be used by programs for benchmarking to manage the implementation of this new technology, as well as for capacity planning, scheduling, and capital budget analysis. Copyright © 2011 The American Association for Thoracic Surgery. All rights reserved.

  11. In-operation inspection technology development-4 ''development of degradation prediction technology for motor-operated valves''

    International Nuclear Information System (INIS)

    Kikuo, Takeshima; Yuichi, Higashikawa; Masahiro, Koike; Kenji, Matsumoto; Eiji, O'shima

    2001-01-01

    A method for degradation predicting technology has been proposed for motor operated valves in nuclear power plants which is based on the concept of condition monitoring for maintenance. This method (degradation prediction technology) eliminates the unnecessary overhaul of valves and realizes high reliability and economy. The degradation mechanism was clarified by long time heating experiments of gasket and gland packing and the wear test for them and stem nut to research valve parts degradation by stress (pressure, temperature, etc) during plant operation. Effective electric power measurements for motor operated valves were confirmed to be useful discovering valve part failures. The motor operated valve degradation prediction system was developed on the basis of the experiment results and mechanism. The system is able to predict the degradation of valve parts (gasket/gland packing, stem, stem nut, etc) utilizing plant data (pressure, temperature, etc) and effective power of the motor. The life of valve parts can be estimated from the experimental results. (authors)

  12. The power of disruptive technological innovation: Transcatheter aortic valve implantation.

    Science.gov (United States)

    Berlin, David B; Davidson, Michael J; Schoen, Frederick J

    2015-11-01

    We sought to evaluate the principles of disruptive innovation, defined as technology innovation that fundamentally shifts performance and utility metrics, as applied to transcatheter aortic valve implantation (TAVI). In particular, we considered implantation procedure, device design, cost, and patient population. Generally cheaper and lower performing, classical disruptive innovations are first commercialized in insignificant markets, promise lower margins, and often parasitize existing usage, representing unattractive investments for established market participants. However, despite presently high unit cost, TAVI is less invasive, treats a "new," generally high risk, patient population, and is generally done by a multidisciplinary integrated heart team. Moreover, at least in the short-term TAVI has not been lower-performing than open surgical aortic valve replacement in high-risk patients. We conclude that TAVI extends the paradigm of disruptive innovation and represents an attractive commercial opportunity space. Moreover, should the long-term performance and durability of TAVI approach that of conventional prostheses, TAVI will be an increasingly attractive commercial opportunity. © 2014 Wiley Periodicals, Inc.

  13. Advancements in valve technology and industry lessons lead to improved plant reliability and cost savings

    International Nuclear Information System (INIS)

    Sharma, V.; Kalsi, M.S.

    2005-01-01

    Plant reliability and safety hinges on the proper functioning of several valves. Recent advancements in valve technology have resulted in new analytical and test methods for evaluating and improving valve and actuator reliability. This is especially significant in critical service applications in which the economic impact of a valve failure on production, outage schedules and consequential damages far surpasses the initial equipment purchase price. This paper presents an overview of recent advances in valve technology driven by reliability concerns and cost savings objectives without comprising safety in the Nuclear Power Industry. This overview is based on over 27 years of experience in supporting US and International nuclear power utilities, and contributing to EPRI, and NSSS Owners' Groups in developing generic models/methodologies to address industry wide issues; performing design basis reviews; and implementing plant-wide valve reliability improvement programs. Various analytical prediction software and hardware solutions and training seminars are now available to implement valve programs covering power plants' lifecycle from the construction phase through life extension and power up rate. These tools and methodologies can enhance valve-engineering activities including the selection, sizing, proper application, condition monitoring, failure analysis, and condition based maintenance optimization with a focus on potential bad actors. This paper offers two such examples, the Kalsi Valve and Actuator Program (KVAP) and Check Valve Analysis and Prioritization (CVAP) [1-3, 8, 9, 11-13]. The advanced, validated torque prediction models incorporated into KVAP software for AOVs and MOVs have improved reliability of margin predictions and enabled cost savings through elimination of unwarranted equipment modifications. CVAP models provides a basis to prioritize the population of valves recommended for preventive maintenance, inspection and/or modification, allowing

  14. Check valve diagnostics utilizing acoustic and magnetic technologies

    International Nuclear Information System (INIS)

    Agostinelli, A.

    1991-01-01

    The potential hazards associated with check valve failures make it necessary to detect check valve problems before they cause significant damage. In the nuclear industry, check valve failures are known to have resulted in damaging water hammer conditions, overpressurization of low pressure systems, steam binding of auxiliary feedwater pumps, and other serious component damage in power plant environments. Similar problems exist in fossil power and various process industries, but the resources dedicated to valve maintenance issues are greatly reduced. However, the trend toward plant life extension, predictive maintenance, and maximum operating efficiency will raise the general awareness of check valve maintenance in commercial (non-nuclear) applications. Although this paper includes specific references to the nuclear industry, the check valve problem conditions and diagnostic techniques apply across all power and process plant environments. The ability to accurately diagnose check valve conditions using non-intrusive, predictive maintenance testing methods allows for a more cost-efficient, productive maintenance program. One particular diagnostic system, called Quickcheck trademark, assists utilities in addressing these concerns. This article presents actual field test data and analysis that demonstrate the power of check valve diagnostics. Prior to presenting the field data, a brief overview of the system is overviewed

  15. High Risk Aortic Valve Replacement - The Challenges of Multiple Treatment Strategies with an Evolving Technology.

    Science.gov (United States)

    Booth, K; Beattie, R; McBride, M; Manoharan, G; Spence, M; Jones, J M

    2016-01-01

    Deciding on the optimal treatment strategy for high risk aortic valve replacement is challenging. Transcatheter Aortic Valve implantation (TAVI) has been available in our centre as an alternative treatment modality for patients since 2008. We present our early experience of TAVI and SAVR (surgical Aortic Valve Replacement) in high risk patients who required SAVR because TAVI could not be performed. The database for Surgical aortic valve and Transcatheter aortic valve replacement referrals was interrogated to identify relevant patients. Survival to hospital discharge was 95.5% in the forty five patients who had SAVR when TAVI was deemed technically unsuitable. One year survival was 86%. Defining who is appropriate for TAVI or high risk SAVR is challenging and multidisciplinary team discussion has never been more prudent in this field of evolving technology with ever decreasing risks of surgery. The introduction of TAVI at our institution has seen a rise in our surgical caseload by approximately by 25%. Overall, the option of aortic valve intervention is being offered to more patients in general which is a substantial benefit in the treatment of aortic valve disease.

  16. Compilation of contract research for the Materials Engineering Branch, Division of Engineering Technology. Annual report for FY 1985. Volume 4

    International Nuclear Information System (INIS)

    1986-03-01

    The compilation of annual reports by contractors to the Materials Engineering Branch of the NRC Office of Research, concentrates on achievements in safety research for the primary system of commercial light water power reactors, particularly with regard to reactor vessels, primary system piping, steam generators and for non-destructive examination of primary system components. This report, covering research conducted during Fiscal Year 1985, is the fourth volume of the series of NUREG-0975, Compilation of Contractor Research for the Materials Engineering Branch, Division of Engineering Technology

  17. Compilation of contract research for the Materials Engineering Branch, Division of Engineering Technology. Annual report for FY 1984. Volume 3

    International Nuclear Information System (INIS)

    1985-04-01

    This compilation of annual reports by contractors to the Materials Engineering Branch of the NRC Office of Research, concentrates on achievments in safety research for the primary system of commercial light water power reactors, particularly with regard to reactor vessels, primary system piping, steam generators and for non-destructive examination of primary system components. This report, covering research conducted during Fiscal Year 1984, is the third volume of the series of NUREG-0975, compilation of Contractor Research for the Materials Engineering Branch, Division of Engineering Technology

  18. In-operation inspection technology development-4 ''development of degradation prediction technology for motor-operated valves''

    Energy Technology Data Exchange (ETDEWEB)

    Kikuo, Takeshima; Yuichi, Higashikawa [Hitachi Engineering and Production Div., Nuclear Systems Div., Hitachi, Ltd., Ibaraki (Japan); Masahiro, Koike [Power and Industrial Systems R and D Lab., Hitachi, Ltd., (Japan); Kenji, Matsumoto [Tokyo Research and Development Center, Japan Power Engineering and Inspection Corp. (Japan); Eiji, O' shima [Tokyo Institute of Technology (Japan)

    2001-07-01

    A method for degradation predicting technology has been proposed for motor operated valves in nuclear power plants which is based on the concept of condition monitoring for maintenance. This method (degradation prediction technology) eliminates the unnecessary overhaul of valves and realizes high reliability and economy. The degradation mechanism was clarified by long time heating experiments of gasket and gland packing and the wear test for them and stem nut to research valve parts degradation by stress (pressure, temperature, etc) during plant operation. Effective electric power measurements for motor operated valves were confirmed to be useful discovering valve part failures. The motor operated valve degradation prediction system was developed on the basis of the experiment results and mechanism. The system is able to predict the degradation of valve parts (gasket/gland packing, stem, stem nut, etc) utilizing plant data (pressure, temperature, etc) and effective power of the motor. The life of valve parts can be estimated from the experimental results. (authors)

  19. An update to inplace testing of safety/relief valves utilizing lift assist technology

    International Nuclear Information System (INIS)

    Heorman, K.R.

    1992-01-01

    Inplace testing of safety and relief valves with lift-assist devices has received mixed reviews from nuclear power plant testing personnel. While many plants use the technology, most limit its use to testing main steam safety valves (even though both OM-1-1981 and PTC 25.3-1976 allow its use for several different service applications). Test coordinator concerns regarding the technology range from lift set point accuracy and repeatability to the quality of the test result output. In addition, OM-1-1981 and PTC 25.3-1976 differ in their approach to the technology. The reasons for the differences between PTC 25.3-1976 and OM-1-1981 are discussed along with additional considerations applicable to the use of the technology in testing liquid service valves. This paper shows that lift assist technology is capable of determining lift set points within the accuracy requirements of OM-1 and PTC 25.3. It also demonstrates that the technology should not be limited to compressible service systems. Also, improvements in test repeatability and output quality are discussed as a function of the assist device design used and valve characteristics. Lift assist testing is often preferred over inplace testing that uses direct system pressure. It is often more cost efficient than bench testing because it does not require removal of critical systems from service and transportation of components. Also, duplicating system temperatures and other environmental factors is not an issue during inplace testing. Valve testing that once required an outage and maintenance period can now be conducted prior to such periods. This approach minimizes the possibility of failures becoming critical path limiting items

  20. Retrieval of a leaflet escaped in a Tri-technologies bileaflet mechanical prosthetic valve.

    Science.gov (United States)

    Cianciulli, Tomás F; Lax, Jorge A; Saccheri, María C; Guidoin, Robert; Salvado, César M; Fernández, Adrián J; Prezioso, Horacio A

    2008-01-01

    The escape of the prosthetic heart valve disc is one of the causes of prosthetic dysfunction that requires emergency surgery. The removal of the embolized disc should be carried out because of the risk of a progressive extrusion on the aortic wall. Several imaging techniques can be used for the detection of the missing disc localization. In this report we describe a 32-year-old man who underwent mitral valve replacement with a Tri-technologies bileaflet valve three years ago, and was admitted in cardiogenic shock. Transesophageal echocardiography showed acute-onset massive mitral regurgitation. The patient underwent emergency replacement of the prosthetic valve. Only one of the two leaflets remained in the removed prosthetic valve. The missing leaflet could not be found within the cardiac cavity. The abdominal fluoroscopic study and plain radiography were unable to detect the escaped leaflet. The abdominal computed tomography scan and the ultrasound showed the escaped leaflet in the terminal portion of the aortic bifurcation. To retrieve the embolized disc laparotomy and aortotomy were performed three months later. The escaped leaflet shows a fracture of one of the pivot systems caused by structural failure. This kind of failure mode is usually the result of high stress concentration.

  1. Strategic use of information and communication technology in valve program management

    International Nuclear Information System (INIS)

    Jakubaitis, V.; Lahey, C

    2012-01-01

    Today it is hard to imagine a time without the internet and the ability to access maintenance manuals, source qualified vendors and research OPEX from utilities a continent away. We do so daily from the comfort of our desk; a few clicks of our mouse and we find everything we need to efficiently plan and execute every aspect of operating and maintaining critical nuclear valves. We assemble our valve work ‘packages’ and print the resultant information for the technician in the field. At the point we hit print, we disconnect our technicians from that information and ourselves from their progress. Employing the paper copy, resources are tasked with the execution of complex valve work in the field. Cumbersome hand offs between stakeholders responsible for different processes jeopardize schedule adherence while front line supervisors attempt to keep everyone up to date, often removing them from a critical task. Occasionally these paper packages are lost or destroyed or found to be missing information, placing daily activities at risk. Leveraging information and communications technology in a Valve Program can significantly change how we operate. The technology exists to ensure field resources have the most up-to-date information. We can be auto-notified when crucial steps are completed, know in advance if additional resources are required or analyze the time it takes to complete critical evolutions. Quality can be improved lessening the need for expensive re-work, workface efficiency and general productivity can also greatly benefit. We can prevent ‘hold’ points from being missed; ensure the correct revision of a procedure is employed or accurately predict when other work can begin. All this accomplished without having our field staff redirect their focus to update management. Technology based tools are slowly moving into our powerhouses and its time we took advantage to properly manage our Valve Programs. (author)

  2. The Concert system - Compiler and runtime technology for efficient concurrent object-oriented programming

    Science.gov (United States)

    Chien, Andrew A.; Karamcheti, Vijay; Plevyak, John; Sahrawat, Deepak

    1993-01-01

    Concurrent object-oriented languages, particularly fine-grained approaches, reduce the difficulty of large scale concurrent programming by providing modularity through encapsulation while exposing large degrees of concurrency. Despite these programmability advantages, such languages have historically suffered from poor efficiency. This paper describes the Concert project whose goal is to develop portable, efficient implementations of fine-grained concurrent object-oriented languages. Our approach incorporates aggressive program analysis and program transformation with careful information management at every stage from the compiler to the runtime system. The paper discusses the basic elements of the Concert approach along with a description of the potential payoffs. Initial performance results and specific plans for system development are also detailed.

  3. The science, technology and research network (STARNET) a searchable thematic compilation of web resources

    Science.gov (United States)

    Blados, W.R.; Cotter, G.A.; Hermann, T.

    2007-01-01

    International alliances in space efforts have resulted in a more rapid diffusion of space technology. This, in turn, increases pressure on organizations to push forward with technological developments and to take steps to maximize their inclusion into the research and development (R&D) process and the overall advancement and enhancement of space technology. To cope with this vast and rapidly growing amount of data and information that is vital to the success of the innovation, the Information Management Committee (IMC) of the Research Technology Agency (RTA) developed the science, technology and research network (STARNET). The purpose of this network is to facilitate access to worldwide information elements in terms of science, technology and overall research. It provides a virtual library with special emphasis on international security; a "one stop" information resource for policy makers, program managers, scientists, engineers, researchers and others. ?? 2007 IEEE.

  4. NRC Information Notice No. 93-01: Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies

    International Nuclear Information System (INIS)

    Grimes, B.K.

    1993-01-01

    Most licensees rely on MOV diagnostic equipment to provide information on the thrust delivered by the motor actuator in opening or closing its valve. The various types of MOV diagnostic equipment estimate valve stem thrust using different parameters, such as displacement of the spring pack or strain in the stem, mounting bolts, or yoke. Liberty Technologies has developed MOV diagnostic equipment, referred to as the Valve Operation Test and Evaluation System (VOTES), that estimates the thrust needed to open or close a valve based on strain of the valve yoke. The VOTES equipment derives thrust from yoke strain that has been calibrated to stem thrust using measured diametral strain of the valve stem and nominal engineering material properties. On October 2, 1992, Liberty Technologies notified the NRC that it had determined that two new factors can affect the thrust values obtained with its equipment. Those factors involve (1) the possible use of improper stem material constants and (2) the failure to account for a torque effect when the VOTES equipment is calibrated by measuring strain in the threaded portion of the valve stem. Liberty Technologies provided information on performing manual calculations to address these factors and stated that its new software, Version 2.3, assists in performing corrections to the thrust data

  5. Electrical hand tools and techniques: A compilation. [utilization of space technology for tools and adapters

    Science.gov (United States)

    1974-01-01

    Space technology utilization for developing tools, adapters, and fixtures and procedures for assembling, installing, and servicing electrical components and equipment are discussed. Some of the items considered are: (1) pivotal screwdriver, (2) termination locator tool for shielded cables, (3) solder application tools, (4) insulation and shield removing tool, and (5) torque wrench adapter for cable connector engaging ring. Diagrams of the various tools and devices are provided.

  6. New compilers speed up applications for Intel-based systems; Intel Compilers pave the way for Intel's Hyper-threading technology

    CERN Multimedia

    2002-01-01

    "Intel Corporation today introduced updated tools to help software developers optimize applications for Intel's expanding family of architectures with key innovations such as Intel's Hyper Threading Technology (1 page).

  7. AVARIS - AREVA Valve Repair in-Situ. Innovative technology and processes

    International Nuclear Information System (INIS)

    Schultz, Ch.

    2012-01-01

    Concept of in-situ welding and turning machine is explained. The AVARIS processes are: Disassembly Evaluation Turning Welding Finish turning Penetration test Grinding Reassembly Result - The seats are within the dimensional and hardness tolerances. The repaired valves with AVARIS as in the case of Isar 2 in 2010 did not show any indications after one year in operation Advantages: Development based on an approved and safe technology; Capability for improving and/or modification of the hardfacing material according to specific system conditions; Minimization of dose exposure (ALARA)

  8. Compilation and evaluation of 14-MeV neutron-activation cross sections for nuclear technology applications. Set I

    International Nuclear Information System (INIS)

    Evain, B.P.; Smith, D.L.; Lucchese, P.

    1985-04-01

    Available 14-MeV experimental neutron activation cross sections are compiled and evaluated for the following reactions of interest for nuclear-energy technology applications: 27 Al(n,p) 27 Mg, Si(n,X) 28 Al, Ti(n,X) 46 Sc, Ti(n,X) 47 Sc, Ti(n,X) 48 Sc, 51 V(n,p) 51 Ti, 51 V(n,α) 48 Sc, Cr(n,X) 52 V, 55 Mn(n,α) 52 V, 55 Mn(n,2n) 54 Mn, Fe(n,X) 54 Mn, 54 Fe(n,α) 51 Cr, 59 Co(n,p) 59 Fe, 59 Co(n,α) 56 Mn, 59 Co(n,2n) 58 Co, 65 Cu(n,p) 65 Ni, Zn(n,X) 64 Cu, 64 Zn(n,2n) 63 Zn, 113 In(n,n')/sup 113m/In, 115 In(n,n') /sup 115m/In. The compiled values are listed and plotted for reference without adjustments. From these collected results those values for which adequate supplementary information on nuclear constants, standards and experimental errors is provided are selected for use in reaction-by-reaction evaluations. These data are adjusted as needed to account for recent revisions in the nuclear constants and cross section standards. The adjusted results are subsequently transformed to equivalent cross sections at 14.7 MeV for the evaluation process. The evaluations are performed utilizing a least-squares method which considers correlations between the experimental data. 440 refs., 41 figs., 46 tabs

  9. Compilation and evaluation of 14-MeV neutron-activation cross sections for nuclear technology applications. Set I

    Energy Technology Data Exchange (ETDEWEB)

    Evain, B.P.; Smith, D.L.; Lucchese, P.

    1985-04-01

    Available 14-MeV experimental neutron activation cross sections are compiled and evaluated for the following reactions of interest for nuclear-energy technology applications: /sup 27/Al(n,p)/sup 27/Mg, Si(n,X)/sup 28/Al, Ti(n,X)/sup 46/Sc, Ti(n,X)/sup 47/Sc, Ti(n,X)/sup 48/Sc, /sup 51/V(n,p)/sup 51/Ti, /sup 51/V(n,..cap alpha..)/sup 48/Sc, Cr(n,X)/sup 52/V, /sup 55/Mn(n,..cap alpha..)/sup 52/V, /sup 55/Mn(n,2n)/sup 54/Mn, Fe(n,X)/sup 54/Mn, /sup 54/Fe(n,..cap alpha..)/sup 51/Cr, /sup 59/Co(n,p)/sup 59/Fe, /sup 59/Co(n,..cap alpha..)/sup 56/Mn, /sup 59/Co(n,2n)/sup 58/Co, /sup 65/Cu(n,p)/sup 65/Ni, Zn(n,X)/sup 64/Cu, /sup 64/Zn(n,2n)/sup 63/Zn, /sup 113/In(n,n')/sup 113m/In, /sup 115/In(n,n') /sup 115m/In. The compiled values are listed and plotted for reference without adjustments. From these collected results those values for which adequate supplementary information on nuclear constants, standards and experimental errors is provided are selected for use in reaction-by-reaction evaluations. These data are adjusted as needed to account for recent revisions in the nuclear constants and cross section standards. The adjusted results are subsequently transformed to equivalent cross sections at 14.7 MeV for the evaluation process. The evaluations are performed utilizing a least-squares method which considers correlations between the experimental data. 440 refs., 41 figs., 46 tabs.

  10. Mechanical damage due to corrosion of parts of pump technology and valves of LWR power installations

    International Nuclear Information System (INIS)

    Hron, J.; Krumpl, M.

    1986-01-01

    Two types are described of uneven corrosion of austenitic chromium-nickel steel: pitting and slit corrosion. The occurrence of slit corrosion is typical of parts of pumping technology and valves. The corrosion damage of austenitic chromium-nickel steels spreads as intergranular, transgranular or mixed corrosion. In nuclear power facilities with LWR's, intergranular corrosion is due to chlorides and sulphur compounds while transgranular corrosion is due to the presence of dissolved oxygen and chlorides. In mechanically stressed parts, stress corrosion takes place. The recommended procedures are discussed of reducing the corrosion-mechanical damage of pumping equipment of light water reactors during design, production and assembly. During the service of the equipment, corrosion cracks are detected using nondestructive methods and surface cracks are repaired by grinding and welding. (E.S.)

  11. Acceptance and introduction of disruptive technologies - simple steps to build a fully functional pulmonary valved stent.

    Science.gov (United States)

    Huber, Christoph H; Marty, Bettina; von Segesser, Ludwig K

    2007-08-01

    Valved stents are new land for cardiac surgeons even though they are being used more frequently by interventional disciplines. This paper presents simple steps to build a patient-specific pulmonary valved stent and its delivery device. The design concept was tested by random participants at a med-tech meeting. The valved stent is constructed by linking an endoprosthetic graft with a valved-jugular-vein. The delivery device is made from a modified 5-ml syringe. Of 72 participants, 66 (92%) built and 60 participants implanted the device successfully into the targeted pulmonary position via a trans-infundibular access.

  12. A broad look at separator material technology for valve-regulated lead/acid batteries

    Energy Technology Data Exchange (ETDEWEB)

    Zguris, G.C. [Hollingsworth and Vose, West Groton, MA (United States)

    1998-05-18

    Recent research has proved the importance of a constant force of 40 kPa or greater on the paste solidus-grid interface. This has lead to increased interest in re-examining the microglass separator and the system that the plate-separator interaction forms. This renewed interest has resulted in new separator ideas and the revisiting of concepts tried in the early days of valve-regulated lead/acid (VRLA) technology. The paper is divided into two parts. The first part examines some past separator developments that have been tried but are presently not accepted by the general VRLA community. This is due to the excellent performance of the microglass separator used so successfully during the last 20 years. Many fundamental questions that need to be asked regarding the selection of a new separator system have long ago been forgotten. The second part of the paper reviews some fundamental aspects of separator selection, and some important attributes that the separator must provide based on current knowledge of the separator system. Attributes such as toughness, corrosion resistance, compression, wicking, stratification, porosity and conformability are discussed. (orig.)

  13. Compilation of contract research for the Chemical Engineering Branch, Division of Engineering Technology. Annual report for FY 1985

    International Nuclear Information System (INIS)

    1986-07-01

    This compilation of annual research reports by the contractors to the Chemical Engineering Branch, DET, is published to disseminate information from ongoing programs and covers research conducted during fiscal year 1985. The programs covered in this document include research on: (1) engineered safety feature (ESF) system effectiveness in terms of fission product retention under severe accident conditions; (2) effectiveness and safety aspects of selected decontamination methods; (3) decontamination impacts on solidification and waste disposal; (4) evaluation of nuclear facility decommissioning projects and concepts, and (5) operational schemes to prevent or mitigate the effects of hydrogen combustion during LWR accidents

  14. Study on the Measurement of Valve Leak Rate Using Acoustic Emission Technology

    International Nuclear Information System (INIS)

    Lee, Sang-Guk; Park, Jong-Hyuck; Yoo, Keun-Bae; Lee, Sun-Ki; Hong, Sung-Yull

    2006-01-01

    This study is to estimate the feasibility of acoustic emission(AE) method for the internal leak from the valves. In this study, 4 inch ball water valve leak tests using three different leak path and various leak rates were performed in order to analyze AE properties when leaks arise in valve seat. As a result of leak test for specimens simulated valve seat, we conformed that leak sound amplitude increased in proportion to the increase of leak rate, and leak rates were plotted versus peak acoustic amplitudes recorded within those two narrow frequency bands on each spectrum plot. The resulting plots of leak rate versus peak AE amplitude were the primary basis for determining the feasibility of quantifying leak acoustically. The large amount of data attained also allowed a favorable investigation of the effects of different leak paths, leak rates, pressure differentials and AE sensors on the AE amplitude spectrum. From the experimental results, it was suggested that the AE method for monitoring of leak was feasible. This paper describes quantitative measurements of fluid valve leak rates by the analysis of AE. Experimental apparatus were fabricated to accept a variety of leaking water valves in order to determine what characteristics of AE signal change with leak rate. The data for each valve were generated by varying the leak rate and recording the time averaged amplitude of AE versus frequency. Leak rates were varied by modifying the valve seating surfaces in ways designed to simulate actual defects observed in service. Most of the data analysis involved plotting the leak rate versus signal amplitude at a specific frequency to determine how well the two variables correlate in terms of accuracy, resolution, and repeatability

  15. X-ray light valve (XLV): a novel detectors' technology for digital mammography

    Science.gov (United States)

    Marcovici, Sorin; Sukhovatkin, Vlad; Oakham, Peter

    2014-03-01

    A novel method, based on X-ray Light Valve (XLV) technology, is proposed for making good image quality yet inexpensive flat panel detectors for digital mammography. The digital mammography markets, particularly in the developing countries, demand quality machines at substantially lower prices than the ones available today. Continuous pressure is applied on x-ray detectors' manufacturers to reduce the flat panel detectors' prices. XLV presents a unique opportunity to achieve the needed price - performance characteristics for direct conversion, x-ray detectors. The XLV based detectors combine the proven, superior, spatial resolution of a-Se with the simplicity and low cost of liquid crystals and optical scanning. The x-ray quanta absorbed by a 200 μm a-Se produce electron - hole pairs that move under an electric field to the top and bottom of a-Se layer. This 2D charge distribution creates at the interface with the liquid crystals a continuous (analog) charge image corresponding to the impinging radiation's information. Under the influence of local electrical charges next to them, the liquid crystals twist proportionally to the charges and vary their light reflectivity. A scanning light source illuminates the liquid crystals while an associated, pixilated photo-detector, having a 42 μm pixel size, captures the light reflected by the liquid crystals and converts it in16 bit words that are transmitted to the machine for image processing and display. The paper will describe a novel XLV, 25 cm x 30 cm, flat panel detector structure and its underlying physics as well as its preliminary performance measured on several engineering prototypes. In particular, the paper will present the results of measuring XLV detectors' DQE, MTF, dynamic range, low contrast resolution and dynamic behavior. Finally, the paper will introduce the new, low cost, XLV detector based, digital mammography machine under development at XLV Diagnostics Inc.

  16. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  17. Fast-responding liquid crystal light-valve technology for color-sequential display applications

    Science.gov (United States)

    Janssen, Peter J.; Konovalov, Victor A.; Muravski, Anatoli A.; Yakovenko, Sergei Y.

    1996-04-01

    A color sequential projection system has some distinct advantages over conventional systems which make it uniquely suitable for consumer TV as well as high performance professional applications such as computer monitors and electronic cinema. A fast responding light-valve is, clearly, essential for a good performing system. Response speed of transmissive LC lightvalves has been marginal thus far for good color rendition. Recently, Sevchenko Institute has made some very fast reflective LC cells which were evaluated at Philips Labs. These devices showed sub millisecond-large signal-response times, even at room temperature, and produced good color in a projector emulation testbed. In our presentation we describe our highly efficient color sequential projector and demonstrate its operation on video tape. Next we discuss light-valve requirements and reflective light-valve test results.

  18. Strengthening of the nuclear valve sealing surface by laser cladding technology

    International Nuclear Information System (INIS)

    Shi Shihong; Huang Guodong

    1998-07-01

    A 5 kW laser with CO 2 flow transverse for cladding Co-base alloy or Ni-base alloy coat on the austenite matrix of the nuclear valve sealing surface is introduced. The results show that, after the sealing surface of valve is processed by the laser cladding, the coat of 3.0 mm thick can be made with smooth surface. The test and comparison analysis indicate that the structure and all performance have obvious advantages over that of the plasma spurt welding, bead welding and flame welding processing

  19. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  20. The effect of peripherally inserted central catheter (PICC) valve technology on catheter occlusion rates--the 'ELeCTRiC' study.

    Science.gov (United States)

    Johnston, Andrew J; Streater, Carmel T; Noorani, Remy; Crofts, Joanne L; Del Mundo, Aldwin B; Parker, Richard A

    2012-01-01

    Peripherally Inserted Central Catheters (PICCs) are increasingly being used to provide short to medium-term central venous access. The current study was designed to test the hypothesis that PICC valve technology does not influence PICC occlusion rates. Intensive care unit (ICU) patients who required a PICC were randomized to one of three types of dual lumen PICC (open ended non-valved, Groshong valve, PASV valve). PICC occlusions were recorded and managed with a protocol that used urokinase. A total of 102 patients were recruited to the study. The overall risk of occlusion per catheter was 35% (95% CI 26% to 44%). The overall rate of occlusion was 76 occlusions per 1000 catheter days (95% CI 61 to 95). Presence or type of valve did not significantly influence this rate (open-ended non-valved PICC 38% of catheters, 79 occlusions per 1000 catheter days; Groshong 38% of catheters, 60 occlusions per 1000 catheter days; PASV 27% of catheters, 99 occlusions per 1000 catheter days). The dose of urokinase required to treat PICC occlusions did not significantly differ between PICC types. Valved PICCs do not appear to influence PICC occlusion rates.

  1. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  2. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  3. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  4. Transcatheter aortic valve replacement in patients with severe aortic stenosis who are at high risk for surgical complications: summary assessment of the California Technology Assessment Forum.

    Science.gov (United States)

    Tice, Jeffrey A; Sellke, Frank W; Schaff, Hartzell V

    2014-08-01

    The California Technology Assessment Forum is dedicated to assessment and public reporting of syntheses of available data on medical technologies. In this assessment, transcatheter aortic valve replacement (TAVR) was evaluated for patients with severe aortic stenosis (AS) who are at high risk for complications. In this assessment, 5 criteria were used: Regulatory approval, sufficient scientific evidence to allow conclusions on effectiveness, evidence that the technology improves net health outcomes, evidence that the technology is as beneficial as established methods, and availability of the technology outside investigational settings. In this assessment, all 5 criteria were judged to have been met. The primary benefit of TAVR is the ability to treat AS in patients who would otherwise be ineligible for surgical aortic valve replacement. It may also be useful for patients at high surgical risk by potentially reducing periprocedural complications and avoiding the morbidity and recovery from undergoing heart surgery. Potential harms include the need for conversion to an open procedure, perioperative death, myocardial infarction, stroke, bleeding, valve embolization, aortic regurgitation, heart block that requires a permanent pacemaker, renal failure, pulmonary failure, and major vascular complications such as cardiac perforation or arterial dissection. Potential long-term harms include death, stroke, valve failure or clotting, and endocarditis. As highlighted at the February 2012 California Technology Assessment Forum meeting, the dispersion of this technology to new centers across the United States must proceed with careful thought given to training and proctoring multidisciplinary teams to become new centers of excellence. TAVR is a potentially lifesaving procedure that may improve quality of life for patients at high risk for surgical AVR. However, attention needs to be paid to appropriate patient selection, their preoperative evaluation, surgical techniques, and

  5. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  6. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  7. Engineering a compiler

    CERN Document Server

    Cooper, Keith D

    2012-01-01

    As computing has changed, so has the role of both the compiler and the compiler writer. The proliferation of processors, environments, and constraints demands an equally large number of compilers. To adapt, compiler writers retarget code generators, add optimizations, and work on issues such as code space or power consumption. Engineering a Compiler re-balances the curriculum for an introductory course in compiler construction to reflect the issues that arise in today's practice. Authors Keith Cooper and Linda Torczon convey both the art and the science of compiler construction and show best practice algorithms for the major problems inside a compiler. ·Focuses on the back end of the compiler-reflecting the focus of research and development over the last decade ·Applies the well-developed theory behind scanning and parsing to introduce concepts that play a critical role in optimization and code generation. ·Introduces the student to optimization through data-flow analysis, SSA form, and a selection of sc...

  8. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  9. SPARQL compiler for Bobox

    OpenAIRE

    Čermák, Miroslav

    2013-01-01

    The goal of the work is to design and implement a SPARQL compiler for the Bobox system. In addition to lexical and syntactic analysis corresponding to W3C standard for SPARQL language, it performs semantic analysis and optimization of queries. Compiler will constuct an appropriate model for execution in Bobox, that depends on the physical database schema.

  10. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  11. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  12. An exploratory discussion on business files compilation

    International Nuclear Information System (INIS)

    Gao Chunying

    2014-01-01

    Business files compilation for an enterprise is a distillation and recreation of its spiritual wealth, from which the applicable information can be available to those who want to use it in a fast, extensive and precise way. Proceeding from the effects of business files compilation on scientific researches, productive constructions and developments, this paper in five points discusses the way how to define topics, analyze historical materials, search or select data and process it to an enterprise archives collection. Firstly, to expound the importance and necessity of business files compilation in production, operation and development of an company; secondly, to present processing methods from topic definition, material searching and data selection to final examination and correction; thirdly, to define principle and classification in order to make different categories and levels of processing methods available to business files compilation; fourthly, to discuss the specific method how to implement a file compilation through a documentation collection upon principle of topic definition gearing with demand; fifthly, to address application of information technology to business files compilation in view point of widely needs for business files so as to level up enterprise archives management. The present discussion focuses on the examination and correction principle of enterprise historical material compilation and the basic classifications as well as the major forms of business files compilation achievements. (author)

  13. C to VHDL compiler

    Science.gov (United States)

    Berdychowski, Piotr P.; Zabolotny, Wojciech M.

    2010-09-01

    The main goal of C to VHDL compiler project is to make FPGA platform more accessible for scientists and software developers. FPGA platform offers unique ability to configure the hardware to implement virtually any dedicated architecture, and modern devices provide sufficient number of hardware resources to implement parallel execution platforms with complex processing units. All this makes the FPGA platform very attractive for those looking for efficient heterogeneous, computing environment. Current industry standard in development of digital systems on FPGA platform is based on HDLs. Although very effective and expressive in hands of hardware development specialists, these languages require specific knowledge and experience, unreachable for most scientists and software programmers. C to VHDL compiler project attempts to remedy that by creating an application, that derives initial VHDL description of a digital system (for further compilation and synthesis), from purely algorithmic description in C programming language. This idea itself is not new, and the C to VHDL compiler combines the best approaches from existing solutions developed over many previous years, with the introduction of some new unique improvements.

  14. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  15. The German Aortic Valve Registry (GARY): a nationwide registry for patients undergoing invasive therapy for severe aortic valve stenosis.

    Science.gov (United States)

    Beckmann, A; Hamm, C; Figulla, H R; Cremer, J; Kuck, K H; Lange, R; Zahn, R; Sack, S; Schuler, G C; Walther, T; Beyersdorf, F; Böhm, M; Heusch, G; Funkat, A K; Meinertz, T; Neumann, T; Papoutsis, K; Schneider, S; Welz, A; Mohr, F W

    2012-07-01

    Background The increasing prevalence of severe aortic valve defects correlates with the increase of life expectancy. For decades, surgical aortic valve replacement (AVR), under the use of extracorporeal circulation, has been the gold standard for treatment of severe aortic valve diseases. In Germany ~12,000 patients receive isolated aortic valve surgery per year. For some time, percutaneous balloon valvuloplasty has been used as a palliative therapeutic option for very few patients. Currently, alternatives for the established surgical procedures such as transcatheter aortic valve implantation (TAVI) have become available, but there are only limited data from randomized studies or low-volume registries concerning long-time outcome. In Germany, the implementation of this new technology into hospital care increased rapidly in the past few years. Therefore, the German Aortic Valve Registry (GARY) was founded in July 2010 including all available therapeutic options and providing data from a large quantity of patients.Methods The GARY is assembled as a complete survey for all invasive therapies in patients with relevant aortic valve diseases. It evaluates the new therapeutic options and compares them to surgical AVR. The model for data acquisition is based on three data sources: source I, the mandatory German database for external performance measurement; source II, a specific registry dataset; and source III, a follow-up data sheet (generated by phone interview). Various procedures will be compared concerning observed complications, mortality, and quality of life up to 5 years after the initial procedure. Furthermore, the registry will enable a compilation of evidence-based indication criteria and, in addition, also a comparison of all approved operative procedures, such as Ross or David procedures, and the use of different mechanical or biological aortic valve prostheses.Results Since the launch of data acquisition in July 2010, almost all institutions performing

  16. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  17. Hardfacing materials and processes for valve applications

    International Nuclear Information System (INIS)

    Matthews, S.J.; Crook, P.

    1982-01-01

    The subject of hardfacing is a very high technology effort especially in the valve industry. The technology is manifested by the need for sophisticated high performance hardfacing alloys required to resist the demanding environments of fluid flow control valve service. High technology is also found in the automated methods currently being used to efficiently deposit high quality hardfacing overlays. 3 figures, 3 tables

  18. Compilation of results 1987

    International Nuclear Information System (INIS)

    1987-01-01

    A compilation is carried out which in concentrated form presents reports on research and development within the nuclear energy field covering a two and a half years period. The foregoing report was edited in December 1984. The projects are presendted with title, project number, responsible unit, person to contact and short result reports. The result reports consist of short summaries over each project. (L.F.)

  19. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  20. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  1. Safety and maintenance engineering: A compilation

    Science.gov (United States)

    1974-01-01

    A compilation is presented for the dissemination of information on technological developments which have potential utility outside the aerospace and nuclear communities. Safety of personnel engaged in the handling of hazardous materials and equipment, protection of equipment from fire, high wind, or careless handling by personnel, and techniques for the maintenance of operating equipment are reported.

  2. Compiler Construction Using Java, JavaCC, and Yacc

    CERN Document Server

    Dos Reis, Anthony J

    2012-01-01

    Broad in scope, involving theory, the application of that theory, and programming technology, compiler construction is a moving target, with constant advances in compiler technology taking place. Today, a renewed focus on do-it-yourself programming makes a quality textbook on compilers, that both students and instructors will enjoy using, of even more vital importance. This book covers every topic essential to learning compilers from the ground up and is accompanied by a powerful and flexible software package for evaluating projects, as well as several tutorials, well-defined projects, and tes

  3. Acoustic valve leak detection in nuclear plants

    International Nuclear Information System (INIS)

    Dimmick, J.G.; Dickey, J.W.

    1983-01-01

    Internal valve leakage is a hidden energy loss and can cause or prolong a forced outage. Recent advances in acoustic detection of internal valve leakage have reduced piping system maintenance costs, unnecessary downtime, and energy waste. Extremely short payback periods have been reported by plants applying this technology to preventive maintenance, troubleshooting, energy conservation and outage planning. Sensors temporarily attached to the outside of valves and connected to the instruments detect ultrasonic acoustic emissions which are characteristic of internal valve leakage. Since the sensors are attached to the outside of the valves, the time and expense of dismantling the valves or removing them from the systems are eliminated. This paper describes the instrumentation and specific applications to nuclear plant valves, including independent verification of initial findings. Guidelines for potential users, including instrumentation selection, training requirements, application planning, and the choice of in-house versus contract services are discussed

  4. Advanced compiler design and implementation

    CERN Document Server

    Muchnick, Steven S

    1997-01-01

    From the Foreword by Susan L. Graham: This book takes on the challenges of contemporary languages and architectures, and prepares the reader for the new compiling problems that will inevitably arise in the future. The definitive book on advanced compiler design This comprehensive, up-to-date work examines advanced issues in the design and implementation of compilers for modern processors. Written for professionals and graduate students, the book guides readers in designing and implementing efficient structures for highly optimizing compilers for real-world languages. Covering advanced issues in fundamental areas of compiler design, this book discusses a wide array of possible code optimizations, determining the relative importance of optimizations, and selecting the most effective methods of implementation. * Lays the foundation for understanding the major issues of advanced compiler design * Treats optimization in-depth * Uses four case studies of commercial compiling suites to illustrate different approache...

  5. Biomedicine: A compilation

    Science.gov (United States)

    1973-01-01

    Developments in NASA technology of possible interest to outside users are reported. Complied are descriptions of a number of instruments that have proven useful in monitoring and treating patients. Described are several diagnostic, prosthetic, and therapeutic devices as well as patent information on new innovations in aerospace medicine technology.

  6. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  7. Compilation of Theses Abstracts

    National Research Council Canada - National Science Library

    2005-01-01

    ... the Internet. The Internet, however, was conceived in the minds of government employees. Just as government influenced the development of the Internet, the same can be said of Radio Frequency Identification (RFID) Technology...

  8. Compiler Feedback using Continuous Dynamic Compilation during Development

    DEFF Research Database (Denmark)

    Jensen, Nicklas Bo; Karlsson, Sven; Probst, Christian W.

    2014-01-01

    to optimization. This tool can help programmers understand what the optimizing compiler has done and suggest automatic source code changes in cases where the compiler refrains from optimizing. We have integrated our tool into an integrated development environment, interactively giving feedback as part...

  9. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  10. Metallurgy: A compilation

    Science.gov (United States)

    1973-01-01

    A technology utilization program is presented for the dissemination of information on technological developments which have potential utility outside the aerospace and nuclear communities. Discussion is restricted to the effects of hydrogen on a variety of metal alloys, and the mechanical properties of some recently developed alloys. Hydrogen at both low and high pressure is shown to have adverse effects on alloys such as ultrahigh-strength steels, irradiated steels, columbium, inconel alloys, titanium alloys, and certain stainless steels. The mechanical and physical properties of a wide range of alloys, their performance at elevated temperatures, and some of the processes involved in their development are also considered.

  11. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  12. Compilation of Theses Abstracts

    Science.gov (United States)

    2005-06-01

    Infrastructure, Cost Estimate, Photovoltaic Power Conversion, PVPC, Solar PV System, Vines, MPPT A STUDY ON PERFORMANCE BASED LOGISTICS...sine-triangle pulse width modulation algorithm. The controller and converter are used to power a quarter-horsepower three-phase induction motor...3 The Photovoltaic Power Converter: A Technology Readiness Assessment................................................... 4 Performance Metrics for

  13. Compiling a 50-year journey

    DEFF Research Database (Denmark)

    Hutton, Graham; Bahr, Patrick

    2017-01-01

    Fifty years ago, John McCarthy and James Painter published the first paper on compiler verification, in which they showed how to formally prove the correctness of a compiler that translates arithmetic expressions into code for a register-based machine. In this article, we revisit this example...

  14. A Note on Compiling Fortran

    Energy Technology Data Exchange (ETDEWEB)

    Busby, L. E. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-09-01

    Fortran modules tend to serialize compilation of large Fortran projects, by introducing dependencies among the source files. If file A depends on file B, (A uses a module defined by B), you must finish compiling B before you can begin compiling A. Some Fortran compilers (Intel ifort, GNU gfortran and IBM xlf, at least) offer an option to ‘‘verify syntax’’, with the side effect of also producing any associated Fortran module files. As it happens, this option usually runs much faster than the object code generation and optimization phases. For some projects on some machines, it can be advantageous to compile in two passes: The first pass generates the module files, quickly; the second pass produces the object files, in parallel. We achieve a 3.8× speedup in the case study below.

  15. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  16. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  17. Compilation of requests for nuclear data

    International Nuclear Information System (INIS)

    1981-03-01

    A request list for nuclear data which was produced from a computerized data file by the National Nuclear Data Center is presented. The request list is given by target nucleus (isotope) and then reaction type. The purpose of the compilation is to summarize the current needs of US Nuclear Energy programs and other applied technologies for nuclear data. Requesters are identified by laboratory, last name, and sponsoring US government agency

  18. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  19. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  20. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  1. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  2. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  3. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  4. Algorithmic synthesis using Python compiler

    Science.gov (United States)

    Cieszewski, Radoslaw; Romaniuk, Ryszard; Pozniak, Krzysztof; Linczuk, Maciej

    2015-09-01

    This paper presents a python to VHDL compiler. The compiler interprets an algorithmic description of a desired behavior written in Python and translate it to VHDL. FPGA combines many benefits of both software and ASIC implementations. Like software, the programmed circuit is flexible, and can be reconfigured over the lifetime of the system. FPGAs have the potential to achieve far greater performance than software as a result of bypassing the fetch-decode-execute operations of traditional processors, and possibly exploiting a greater level of parallelism. This can be achieved by using many computational resources at the same time. Creating parallel programs implemented in FPGAs in pure HDL is difficult and time consuming. Using higher level of abstraction and High-Level Synthesis compiler implementation time can be reduced. The compiler has been implemented using the Python language. This article describes design, implementation and results of created tools.

  5. A compiler for variational forms

    OpenAIRE

    Kirby, Robert C.; Logg, Anders

    2011-01-01

    As a key step towards a complete automation of the finite element method, we present a new algorithm for automatic and efficient evaluation of multilinear variational forms. The algorithm has been implemented in the form of a compiler, the FEniCS Form Compiler FFC. We present benchmark results for a series of standard variational forms, including the incompressible Navier-Stokes equations and linear elasticity. The speedup compared to the standard quadrature-based approach is impressive; in s...

  6. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  7. Novel Active Combustion Control Valve

    Science.gov (United States)

    Caspermeyer, Matt

    2014-01-01

    This project presents an innovative solution for active combustion control. Relative to the state of the art, this concept provides frequency modulation (greater than 1,000 Hz) in combination with high-amplitude modulation (in excess of 30 percent flow) and can be adapted to a large range of fuel injector sizes. Existing valves often have low flow modulation strength. To achieve higher flow modulation requires excessively large valves or too much electrical power to be practical. This active combustion control valve (ACCV) has high-frequency and -amplitude modulation, consumes low electrical power, is closely coupled with the fuel injector for modulation strength, and is practical in size and weight. By mitigating combustion instabilities at higher frequencies than have been previously achieved (approximately 1,000 Hz), this new technology enables gas turbines to run at operating points that produce lower emissions and higher performance.

  8. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  9. FY 1998 annual report on the compilation of the data related to new energy technology development. Photovoltaic power generation; 1998 nendo shin energy gijutsu kaihatsu kankei data shu sakusei chosa hokokusho. Taiyoko hatsuden

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    The data, centered by those related to generation of photovoltaic (PV) power as one branch of new energy, are collected and systematically compiled under the following fields. (Significance of adopting PV power systems) describes, e.g., CO2 reduction effect and energy pay-back time for different customers, i.e., nation, local governments, industries and individual households. (Present status of solar cell markets) describes solar cell production by region, cell technology and industry; shipments by application; production values; and prices. (PV system policies overseas) compares the policies of the industrialized countries for PV power systems with those of Japan. (Introduction of PV power systems overseas) compares situations of various countries in PV power system introduction with those of Japan with respect to estimated quantities of PV systems installed and target quantities. (Financial supports for PV power system installation) describes subsidies, tax benefits and loans adopted in Japan. Other items covered herein include transition of PV-related budgets, flow of PV system introduction, measures taken by central and local governments, and contacts for PV-related enterprises. (NEDO)

  10. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  11. Transcatheter Mitral Valve Devices - Functional Mechanical Designs.

    Science.gov (United States)

    Kliger, Chad

    2014-03-01

    Mitral regurgitation is a complex disorder involving a multitude of components of the mitral apparatus. With the desire for less invasive treatment approaches, transcatheter mitral valve therapies (TMVT) are directed at these components and available at varying stages of development. Therapeutic advancements and the potential to combine technologies may further improve their efficacy and safety. Transcatheter mitral valve replacement, while preserving the mitral apparatus, may emerge as an alternative or even a more suitable treatment option. In addition, early data on transcatheter mitral valve-in-valve and valve-in-ring implantation are encouraging and this approach may be an alternative to reoperation in the high-risk patient. This review details the expanding functional mechanical designs of current active TMVT.

  12. Advanced C and C++ compiling

    CERN Document Server

    Stevanovic, Milan

    2014-01-01

    Learning how to write C/C++ code is only the first step. To be a serious programmer, you need to understand the structure and purpose of the binary files produced by the compiler: object files, static libraries, shared libraries, and, of course, executables.Advanced C and C++ Compiling explains the build process in detail and shows how to integrate code from other developers in the form of deployed libraries as well as how to resolve issues and potential mismatches between your own and external code trees.With the proliferation of open source, understanding these issues is increasingly the res

  13. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  14. 1988 Bulletin compilation and index

    International Nuclear Information System (INIS)

    1989-02-01

    This document is published to provide current information about the national program for managing spent fuel and high-level radioactive waste. This document is a compilation of issues from the 1988 calendar year. A table of contents and one index have been provided to assist in finding information

  15. Compilation of solar abundance data

    International Nuclear Information System (INIS)

    Hauge, Oe.; Engvold, O.

    1977-01-01

    Interest in the previous compilations of solar abundance data by the same authors (ITA--31 and ITA--39) has led to this third, revised edition. Solar abundance data of 67 elements are tabulated and in addition upper limits for the abundances of 5 elements are listed. References are made to 167 papers. A recommended abundance value is given for each element. (JIW)

  16. 1988 Bulletin compilation and index

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1989-02-01

    This document is published to provide current information about the national program for managing spent fuel and high-level radioactive waste. This document is a compilation of issues from the 1988 calendar year. A table of contents and one index have been provided to assist in finding information.

  17. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  18. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  19. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  20. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  1. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  2. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  3. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  4. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  5. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  6. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  7. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  8. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  9. Simulation of proportional control of hydraulic actuator using digital hydraulic valves

    Science.gov (United States)

    Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.

    2017-11-01

    Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.

  10. HAL/S-FC compiler system specifications

    Science.gov (United States)

    1976-01-01

    This document specifies the informational interfaces within the HAL/S-FC compiler, and between the compiler and the external environment. This Compiler System Specification is for the HAL/S-FC compiler and its associated run time facilities which implement the full HAL/S language. The HAL/S-FC compiler is designed to operate stand-alone on any compatible IBM 360/370 computer and within the Software Development Laboratory (SDL) at NASA/JSC, Houston, Texas.

  11. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Energy Technology Data Exchange (ETDEWEB)

    Schaeck, S.; Stoermer, A.O.; Hockgeiger, E. [BMW Group, Powertrain Development, Energy Storage, Hufelandstrasse 4, 80788 Muenchen (Germany)

    2009-05-01

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 C and at 3 C battery temperature. (author)

  12. Implementation of a Low Frame-Rate Protocol and Noise-Reduction Technology to Minimize Radiation Dose in Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Maccagni, Davide; Candilio, Luciano; Latib, Azeem; Godino, Cosmo; Chieffo, Alaide; Montorfano, Matteo; Colombo, Antonio; Azzalini, Lorenzo

    2018-05-01

    Limiting radiation exposure is necessary in radiological procedures. This study evaluates the impact of a radiological low frame-rate protocol in a standard angiographic system and the implementation of a noise-reduction technology (NRT) on patient radiation exposure during transcatheter aortic valve replacement (TAVR). Transfemoral TAVR procedures performed between February 2016 and February 2017 were analyzed according to two angiographic systems, Standard and NRT, and further divided in four subgroups: (1) Standard 15 frames per second (fps) with 15 fps for both fluoroscopy and cine acquisitions; (2) Standard 7.5 fps with 7.5 fps for both fluoroscopy and cine acquisitions; (3) NRT 15 fps with 15 fps for both fluoroscopy and cine acquisitions; and (4) NRT 7.5 fps with 15 fps for fluoroscopy and 7.5 fps for cine acquisitions. Study endpoints were kerma area product (KAP) and cumulative air kerma at interventional reference point (AK at IRP). Significant differences were found in KAP (153 Gy·cm² [IQR, 95-234 Gy·cm²] vs 78.3 Gy·cm² [IQR, 54.4-103.5 Gy·cm²]; Pfps and Standard 7.5 fps groups (184 Gy·cm² [IQR, 128-262 Gy·cm²] vs 106.8 Gy·cm² [IQR, 76.87-181 Gy·cm²] [P<.01] and 0.973 Gy [IQR, 0.642-1.786 Gy] vs 0.64 Gy [IQR, 0.489-0.933 Gy] [P<.01], respectively). The present study suggests that the low frame-rate protocol in Standard system and NRT implementation allows a marked reduction of patient radiation exposure in TAVR procedures.

  13. Micro-hybrid electric vehicle application of valve-regulated lead-acid batteries in absorbent glass mat technology: Testing a partial-state-of-charge operation strategy

    Science.gov (United States)

    Schaeck, S.; Stoermer, A. O.; Hockgeiger, E.

    The BMW Group has launched two micro-hybrid functions in high volume models in order to contribute to reduction of fuel consumption in modern passenger cars. Both the brake energy regeneration (BER) and the auto-start-stop function (ASSF) are based on the conventional 14 V vehicle electrical system and current series components with only little modifications. An intelligent control algorithm of the alternator enables recuperative charging in braking and coasting phases, known as BER. By switching off the internal combustion engine at a vehicle standstill the idling fuel consumption is effectively reduced by ASSF. By reason of economy and package a lead-acid battery is used as electrochemical energy storage device. The BMW Group assembles valve-regulated lead-acid (VRLA) batteries in absorbent glass mat (AGM) technology in the micro-hybrid electrical power system since special challenges arise for the batteries. By field data analysis a lower average state-of-charge (SOC) due to partial state-of-charge (PSOC) operation and a higher cycling rate due to BER and ASSF are confirmed in this article. Similar to a design of experiment (DOE) like method we present a long-term lab investigation. Two types of 90 Ah VRLA AGM batteries are operated with a test bench profile that simulates the micro-hybrid vehicle electrical system under varying conditions. The main attention of this lab testing is focused on capacity loss and charge acceptance over cycle life. These effects are put into context with periodically refresh charging the batteries in order to prevent accelerated battery aging due to hard sulfation. We demonstrate the positive effect of refresh chargings concerning preservation of battery charge acceptance. Furthermore, we observe moderate capacity loss over 90 full cycles both at 25 °C and at 3 °C battery temperature.

  14. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  15. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  16. VFC: The Vienna Fortran Compiler

    Directory of Open Access Journals (Sweden)

    Siegfried Benkner

    1999-01-01

    Full Text Available High Performance Fortran (HPF offers an attractive high‐level language interface for programming scalable parallel architectures providing the user with directives for the specification of data distribution and delegating to the compiler the task of generating an explicitly parallel program. Available HPF compilers can handle regular codes quite efficiently, but dramatic performance losses may be encountered for applications which are based on highly irregular, dynamically changing data structures and access patterns. In this paper we introduce the Vienna Fortran Compiler (VFC, a new source‐to‐source parallelization system for HPF+, an optimized version of HPF, which addresses the requirements of irregular applications. In addition to extended data distribution and work distribution mechanisms, HPF+ provides the user with language features for specifying certain information that decisively influence a program’s performance. This comprises data locality assertions, non‐local access specifications and the possibility of reusing runtime‐generated communication schedules of irregular loops. Performance measurements of kernels from advanced applications demonstrate that with a high‐level data parallel language such as HPF+ a performance close to hand‐written message‐passing programs can be achieved even for highly irregular codes.

  17. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  18. Motor operated valves problems tests and simulations

    International Nuclear Information System (INIS)

    Pinier, D.; Haas, J.L.

    1996-01-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a open-quotes boilerclose quotes effect: determination of the necessary modifications: development and testing of anti-boiler effect systems

  19. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  20. A Performance Tuning Methodology with Compiler Support

    Directory of Open Access Journals (Sweden)

    Oscar Hernandez

    2008-01-01

    Full Text Available We have developed an environment, based upon robust, existing, open source software, for tuning applications written using MPI, OpenMP or both. The goal of this effort, which integrates the OpenUH compiler and several popular performance tools, is to increase user productivity by providing an automated, scalable performance measurement and optimization system. In this paper we describe our environment, show how these complementary tools can work together, and illustrate the synergies possible by exploiting their individual strengths and combined interactions. We also present a methodology for performance tuning that is enabled by this environment. One of the benefits of using compiler technology in this context is that it can direct the performance measurements to capture events at different levels of granularity and help assess their importance, which we have shown to significantly reduce the measurement overheads. The compiler can also help when attempting to understand the performance results: it can supply information on how a code was translated and whether optimizations were applied. Our methodology combines two performance views of the application to find bottlenecks. The first is a high level view that focuses on OpenMP/MPI performance problems such as synchronization cost and load imbalances; the second is a low level view that focuses on hardware counter analysis with derived metrics that assess the efficiency of the code. Our experiments have shown that our approach can significantly reduce overheads for both profiling and tracing to acceptable levels and limit the number of times the application needs to be run with selected hardware counters. In this paper, we demonstrate the workings of this methodology by illustrating its use with selected NAS Parallel Benchmarks and a cloud resolving code.

  1. A review of design and modeling of magnetorheological valve

    Science.gov (United States)

    Abd Fatah, Abdul Yasser; Mazlan, Saiful Amri; Koga, Tsuyoshi; Zamzuri, Hairi; Zeinali, Mohammadjavad; Imaduddin, Fitrian

    2015-01-01

    Following recent rapid development of researches in utilizing Magnetorheological (MR) fluid, a smart material that can be magnetically controlled to change its apparent viscosity instantaneously, a lot of applications have been established to exploit the benefits and advantages of using the MR fluid. One of the most important applications for MR fluid in devices is the MR valve, where it uses the popular flow or valve mode among the available working modes for MR fluid. As such, MR valve is widely applied in a lot of hydraulic actuation and vibration reduction devices, among them are dampers, actuators and shock absorbers. This paper presents a review on MR valve, discusses on several design configurations and the mathematical modeling for the MR valve. Therefore, this review paper classifies the MR valve based on the coil configuration and geometrical arrangement of the valve, and focusing on four different mathematical models for MR valve: Bingham plastic, Herschel-Bulkley, bi-viscous and Herschel-Bulkley with pre-yield viscosity (HBPV) models for calculating yield stress and pressure drop in the MR valve. Design challenges and opportunities for application of MR fluid and MR valve are also highlighted in this review. Hopefully, this review paper can provide basic knowledge on design and modeling of MR valve, complementing other reviews on MR fluid, its applications and technologies.

  2. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  3. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    M. Senthilkumar (Newgen Imaging) 1461 1996 Oct 15 13:05:22

    BHUVANESHWAR. Biomedical Technology Wing, Sree Chitra Tirunal Institute for Medical Sciences. & Technology ... affect the performance of mechanical heart valves. The clinical performance of ... those who cannot be put under anticoagulant therapy, like women who may still wish to bear children, or hemolytic patients.

  4. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  5. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  6. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  7. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  8. PIG 3 - A simple compiler for mercury

    International Nuclear Information System (INIS)

    Bindon, D.C.

    1961-06-01

    A short machine language compilation scheme is described; which will read programmes from paper tape, punched cards, or magnetic tape. The compiler occupies pages 8-15 of the ferrite store during translation. (author)

  9. PIG 3 - A simple compiler for mercury

    Energy Technology Data Exchange (ETDEWEB)

    Bindon, D C [Computer Branch, Technical Assessments and Services Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1961-06-15

    A short machine language compilation scheme is described; which will read programmes from paper tape, punched cards, or magnetic tape. The compiler occupies pages 8-15 of the ferrite store during translation. (author)

  10. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  11. Aortic or Mitral Valve Replacement With the Biocor and Biocor Supra

    Science.gov (United States)

    2017-04-26

    Aortic Valve Insufficiency; Aortic Valve Regurgitation; Aortic Valve Stenosis; Aortic Valve Incompetence; Mitral Valve Insufficiency; Mitral Valve Regurgitation; Mitral Valve Stenosis; Mitral Valve Incompetence

  12. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  13. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  14. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  15. Proving correctness of compilers using structured graphs

    DEFF Research Database (Denmark)

    Bahr, Patrick

    2014-01-01

    it into a compiler implementation using a graph type along with a correctness proof. The implementation and correctness proof of a compiler using a tree type without explicit jumps is simple, but yields code duplication. Our method provides a convenient way of improving such a compiler without giving up the benefits...

  16. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  17. Statistical Compilation of the ICT Sector and Policy Analysis | CRDI ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Statistical Compilation of the ICT Sector and Policy Analysis. As the presence and influence of information and communication technologies (ICTs) continues to widen and deepen, so too does its impact on economic development. However, much work needs to be done before the linkages between economic development ...

  18. Statistical Compilation of the ICT Sector and Policy Analysis | IDRC ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Statistical Compilation of the ICT Sector and Policy Analysis. As the presence and influence of information and communication technologies (ICTs) continues to widen and deepen, so too does its impact on economic development. However, much work needs to be done before the linkages between economic development ...

  19. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  20. Vascular complications associated with transcatheter aortic valve replacement.

    Science.gov (United States)

    Sardar, M Rizwan; Goldsweig, Andrew M; Abbott, J Dawn; Sharaf, Barry L; Gordon, Paul C; Ehsan, Afshin; Aronow, Herbert D

    2017-06-01

    Transcatheter aortic valve replacement (TAVR) is now an accepted pathway for aortic valve replacement for patients who are at prohibitive, severe and intermediate risk for traditional aortic valve surgery. However, with this rising uptrend and adaptation of this new technology, vascular complications and their management remain an Achilles heel for percutaneous aortic valve replacement. The vascular complications are an independent predictor of mortality for patients undergoing TAVR. Early recognition of these complications and appropriate management is paramount. In this article, we review the most commonly encountered vascular complications associated with currently approved TAVR devices and their optimal percutaneous management techniques.

  1. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...

  2. Potential problems will drillstring safety valves

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    In the paper titled ``New generation drill string safety valves,`` presented at the IADC Well Control Conference for Europe, Aberdeen, May 22--24, 1996, documented limitations of presently available drillstring safety valves commonly used as kelly valves and stabbing valves were presented, and industry efforts to develop solutions to these problems were described. Authors of the paper are B.A. Tarr and R.A. Sukup (Mobil E and P Technology Center, Dallas), Dr. R. Luy (ITE, Clausthal, Germany), G. Rabby (Hi-Kalibre, Edmonton, Alberta) and J. Mertsch (ITAG, Celle, Germany). In 1995, the Task Group developed a draft of a new spec, and a DSSV testing program was initiated as a joint industry project, with the Gas Research Institute (GRI) as the major sponsor. Two manufacturers, Hi-Kalibre and ITAG, agreed to build new valves for the testing program. Hi-Kalibre, Edmonton, Alberta, supplied an already-commercial twin floating ball valve for November 1995 testing. This product is being used by Tesco in its portable top drive system. ITAG of Germany supplied a radically improved DSSV design, which was tested in December, and was to be retested in May following modifications.

  3. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  4. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  5. Modification and performance evaluation of a mono-valve engine

    Science.gov (United States)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  6. Pivot design in bileaflet valves.

    Science.gov (United States)

    Vallana, F; Rinaldi, S; Galletti, P M; Nguyen, A; Piwnica, A

    1992-01-01

    The design criteria leading to the development of a new bileaflet valve (Sorin Bicarbon) were derived from the analysis of functional requirements, the performance of existing prostheses, and the availability of an advanced carbon coating technology (Carbofilm). The hinge is the critical element affecting fluid dynamics, durability, and thrombus formation in bileaflet valves. A comparative study of three existing models led to a new hinge design that was based on coupling two spheric surfaces with different radii of curvature (leaflet pivot and hinge recess) and obtained by electroerosion into a Carbofilm-coated metallic housing. In this valve, the point of contact moves continuously by rolling, not sliding. This minimizes friction and wear and allows uninterrupted washing of the blood exposed surfaces even during diastole (a finding established in patients using transesophageal echocardiography). Tricuspid implantation without anticoagulation in 33 sheep did not lead to thrombotic events (follow-up, 40-400 days). In the first 36 clinical implants observed for 15 months (mitral position, size 29; two unrelated deaths), the mean diastolic gradient by echo Doppler was 4 +/- 1.25 mmHg; the functional area was 3.2 +/- 0.6 cm2. No leaflet fracture and no thrombotic or embolic complications were observed clinically using a standard anticoagulant regimen.

  7. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  8. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  9. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  10. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  11. A Class-Specific Optimizing Compiler

    Directory of Open Access Journals (Sweden)

    Michael D. Sharp

    1993-01-01

    Full Text Available Class-specific optimizations are compiler optimizations specified by the class implementor to the compiler. They allow the compiler to take advantage of the semantics of the particular class so as to produce better code. Optimizations of interest include the strength reduction of class:: array address calculations, elimination of large temporaries, and the placement of asynchronous send/recv calls so as to achieve computation/communication overlap. We will outline our progress towards the implementation of a C++ compiler capable of incorporating class-specific optimizations.

  12. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  13. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  14. The use of valves in the SAGD process

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Michael A. [Global Marketing, Oil and Gas, Tyco Valves and Controls (United States)

    2011-07-01

    Steam-assisted gravity drainage (SAGD) is a developing technology, the aim of which is to increase production of bitumen while minimizing its environmental footprint. Valves must meet the process conditions of the operations, which depend on weel depth: deeper reservoirs of bitumen require higher steam injection pressure. A wide range of valves is used throughout the SAGD process. In the water softening plant, butterfly and process lined valves are used. HP gate valves are used for isolation, globe valves for vents/drains/bypasses, along with ARC valves for steam and booster pump projection with steam traps on injection lines in steam injection. Isolation valves are used throughout the low pressure process including ball, gate and triple-offset valves. Pressure management is carried out on all pressure vessels and lines. Control and choke valves are installed on well pads and production. Instrumentation, actuation and controls are installed throughout. In the ideal situation, suppliers and process engineers would work together in the early stages of a project.

  15. Main feedwater valve diagnostics at Waterford 3 nuclear generating station

    International Nuclear Information System (INIS)

    Fitzgerald, W.V.

    1991-01-01

    Pneumatically-operated control valves are coming under increasing scrutiny in nuclear power plants because of their relatively high incident rate. The theory behind a device that could make performance evaluation of these valves simpler and more effective was first described at the original EPRI Power Plant Valve Symposium. The development of this Diagnostic System was completed in 1989, and it was recently used to troubleshoot two main feedwater valves at Louisiana Power and Light's Waterford 3 Power Station. During a cold snap last December, these valves failed to respond to the input signal and, as a result, the plant came off line. An incident report had to be filed, and the plant chose to contact the original equipment manufacturer (OEM) for assistance. This paper describes the original incident involving these valves and then gives a brief description of the diagnostic system and how it works. The balance of the paper then reviews how the OEM and plant personnel utilized the system to evaluate each component of the control valve assembly (I/P transducer, positioner, volume boosters, actuator, and valve body assembly). By simply stroking the valve and monitoring pneumatic signals and valve position, the problem was traced to a malfunctioning positioner and a volume booster that was leaking. The problems were corrected and new performance signatures run for the valves using the system to document their improved operation. This case study demonstrates how new Diagnostic Technology along with OEM involvement can effectively address problems with pneumatically-operated control valves so that root-cause solutions can be implemented

  16. Twenty-five-year experience with the Björk-Shiley convexoconcave heart valve: a continuing clinical concern.

    Science.gov (United States)

    Blot, William J; Ibrahim, Michel A; Ivey, Tom D; Acheson, Donald E; Brookmeyer, Ron; Weyman, Arthur; Defauw, Joseph; Smith, J Kermit; Harrison, Donald

    2005-05-31

    The first Björk-Shiley convexoconcave (BSCC) prosthetic heart valves were implanted in 1978. The 25th anniversary provided a stimulus to summarize the research data relevant to BSCC valve fracture, patient management, and current clinical options. Published and unpublished data on the risks of BSCC valve fracture and replacement were compiled, and strategies for identifying candidates for prophylactic valve reoperation were summarized. By December 2003, outlet strut fractures (OSFs), often with fatal outcomes, had been reported in 633 BSCC valves (0.7% of 86,000 valves implanted). Fractures still continue to occur, but average rates of OSFs in 60 degrees valves are now valve characteristics, especially valve angle and size, with weaker effects associated with other manufacturing variables. OSF risks are mildly lower among women than men but decline sharply with advancing age. The risks of valve replacement typically greatly exceed those of OSF. By comparing individualized estimated risks of OSF versus valve replacement, guidelines have been developed to identify the small percentage of BSCC patients (mostly younger men) who would be expected to have a gain in life expectancy should reoperative surgery be performed. Twenty-five years after the initial BSCC valve implants, fractures continue to occur. Continued monitoring of BSCC patients is needed to track and quantify risks and enable periodic updating of guidelines for patients and their physicians.

  17. High Temperature, High Frequency Fuel Metering Valve, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  18. Pulmonary valve stenosis

    Science.gov (United States)

    ... surgery - discharge Images Heart valves References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman's Cecil ... Saunders; 2016:chap 69. Otto CM, Bownow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ...

  19. Mitral valve regurgitation

    Science.gov (United States)

    ... and dentist if you have a history of heart valve disease or congenital heart disease before treatment. Some people ... the middle Heart, front view References Carabello BA. Valvular heart disease. In: Goldman L, Schafer AI, eds. Goldman-Cecil ...

  20. Aortic Valve Disease

    Science.gov (United States)

    ... team will discuss with you the advantages and disadvantages of both valve types. Regardless of which type ... Diagnosis and Treatment Options Recovery Questions for Your Doctor Will my condition ever get better without treatment? ...

  1. Dry product valve

    International Nuclear Information System (INIS)

    Greaves, James D.

    1984-01-01

    This invention provides a system for delivering particulate radioactive or other toxic wastes to a container in which they can be solidified. The system includes a set of valves that prevent the escape of dusty materials to the atmosphere

  2. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  3. Valve for gas centrifuges

    Science.gov (United States)

    Hahs, Charles A.; Burbage, Charles H.

    1984-01-01

    The invention is a pneumatically operated valve assembly for simultaneously (1) closing gas-transfer lines connected to a gas centrifuge or the like and (2) establishing a recycle path between two of the lines so closed. The valve assembly is especially designed to be compact, fast-acting, reliable, and comparatively inexpensive. It provides large reductions in capital costs for gas-centrifuge cascades.

  4. Coanda effect in valves

    Directory of Open Access Journals (Sweden)

    Uruba Václav

    2017-01-01

    Full Text Available Coanda effect takes place in flow within valves diffuser for certain conditions. The valve plug in half-closed position forms wall-jet, which could be stable or instable, depending on geometry and other conditions. This phenomenon was subject of experimental study using time-resolved PIV technique. For the acquired data analysis the special spatio-temporal methods have been used.

  5. Compressed gas domestic aerosol valve design using high viscous product

    Directory of Open Access Journals (Sweden)

    A Nourian

    2016-10-01

    Full Text Available Most of the current universal consumer aerosol products using high viscous product such as cooking oil, antiperspirants, hair removal cream are primarily used LPG (Liquefied Petroleum Gas propellant which is unfriendly environmental. The advantages of the new innovative technology described in this paper are: i. No butane or other liquefied hydrocarbon gas is used as a propellant and it replaced with Compressed air, nitrogen or other safe gas propellant. ii. Customer acceptable spray quality and consistency during can lifetime iii. Conventional cans and filling technology There is only a feasible energy source which is inert gas (i.e. compressed air to replace VOCs (Volatile Organic Compounds and greenhouse gases, which must be avoided, to improve atomisation by generating gas bubbles and turbulence inside the atomiser insert and the actuator. This research concentrates on using "bubbly flow" in the valve stem, with injection of compressed gas into the passing flow, thus also generating turbulence. The new valve designed in this investigation using inert gases has advantageous over conventional valve with butane propellant using high viscous product (> 400 Cp because, when the valving arrangement is fully open, there are negligible energy losses as fluid passes through the valve from the interior of the container to the actuator insert. The use of valving arrangement thus permits all pressure drops to be controlled, resulting in improved control of atomising efficiency and flow rate, whereas in conventional valves a significant pressure drops occurs through the valve which has a complex effect on the corresponding spray.

  6. A Symmetric Approach to Compilation and Decompilation

    DEFF Research Database (Denmark)

    Ager, Mads Sig; Danvy, Olivier; Goldberg, Mayer

    2002-01-01

    Just as an interpreter for a source language can be turned into a compiler from the source language to a target language, we observe that an interpreter for a target language can be turned into a compiler from the target language to a source language. In both cases, the key issue is the choice of...

  7. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    International Nuclear Information System (INIS)

    Mahrous, A-F.M.; Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P.

    2009-01-01

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing

  8. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    Energy Technology Data Exchange (ETDEWEB)

    Mahrous, A-F.M. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lecturer at the Department of Mechanical Power Engineering, Faculty of Engineering (Shebin El-Kom), Menoufiya University, Shebin El-Kom (Egypt); Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2009-02-15

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing. (author)

  9. Compact UHV valve with field replaceable windows

    International Nuclear Information System (INIS)

    Johnson, E.D.; Freeman, J.; Powell, F.

    1991-01-01

    There are many applications in synchrotron radiation research where window valves can be usefully employed. Examples include gas cells for monochromator calibration, filters for high order light rejection, and as vacuum isolation elements between machine and experimental vacua. Often these devices are fairly expensive, and have only fixed (ie non-removable) windows. The development of a new type of seal technology by VAT for their series 01 valves provides a gate surface which is free from obstructions due to internal mechanical elements. This feature allows a threaded recess to be machined into the gate to receive a removable window frame which can carry standard size Luxel thin film windows. The combination of these features results in a DN 40 (2.75in. conflat flange) valve which provides a clear aperture of 21mm diameter for the window material. 8 refs., 2 figs

  10. Three-dimensional echocardiography in valve disease

    Directory of Open Access Journals (Sweden)

    Cesare Fiorentini

    2009-08-01

    Full Text Available This review covers the role of three-dimensional (3D echocardiography in the diagnosis of heart valve disease. Several factors have contributed to the evolution of this technique, which is currently a simple and routine method: rapid evolution in probe and computer technologies, demonstration that 3D data sets allowed more complete and accurate evaluation of cardiac structures, emerging clinical experience indicating the strong potential particularly in valve diseases, volume and function of the two ventricle measurements and several other fields. This report will review current and future applications of 3D echocardiography in mitral, aortic and tricuspid valve diseases underlying both qualitative (morphologic and quantitative advantages of this technique. (Heart International 2007; 3: 35-41

  11. Engineering Amorphous Systems, Using Global-to-Local Compilation

    Science.gov (United States)

    Nagpal, Radhika

    Emerging technologies are making it possible to assemble systems that incorporate myriad of information-processing units at almost no cost: smart materials, selfassembling structures, vast sensor networks, pervasive computing. How does one engineer robust and prespecified global behavior from the local interactions of immense numbers of unreliable parts? We discuss organizing principles and programming methodologies that have emerged from Amorphous Computing research, that allow us to compile a specification of global behavior into a robust program for local behavior.

  12. Rare early prosthesis obstruction after mitral valve replacement: a case report and literature review

    Directory of Open Access Journals (Sweden)

    Shi Jun

    2012-07-01

    Full Text Available Abstract As a dreadful complication after the mechanical heart valve replacement, prosthetic valve obstruction caused by pannus formation occurs increasingly with time. The authors here present a case of 42-year-old woman who was urgently admitted to hospital with acute heart failure symptoms due to the mechanical mitral valve failure only 3 months after surgery. Transthoracic and transesophageal echocardiography demonstrated that the bileaflet of the mitral prosthesis were completely immobilized with only a small transvalvular jet remained. During the reoperation, the reason of the prosthetic valve obstruction was attributed to the noncircular pannus ingrowth extending from the atrioventricular side. For a better understanding of the prosthetic valve dysfunction caused by pannus formation, the authors then compile a literature review to briefly discuss the status quo of the clinical characteristics of this uncommon complication.

  13. An Extensible Open-Source Compiler Infrastructure for Testing

    Energy Technology Data Exchange (ETDEWEB)

    Quinlan, D; Ur, S; Vuduc, R

    2005-12-09

    Testing forms a critical part of the development process for large-scale software, and there is growing need for automated tools that can read, represent, analyze, and transform the application's source code to help carry out testing tasks. However, the support required to compile applications written in common general purpose languages is generally inaccessible to the testing research community. In this paper, we report on an extensible, open-source compiler infrastructure called ROSE, which is currently in development at Lawrence Livermore National Laboratory. ROSE specifically targets developers who wish to build source-based tools that implement customized analyses and optimizations for large-scale C, C++, and Fortran90 scientific computing applications (on the order of a million lines of code or more). However, much of this infrastructure can also be used to address problems in testing, and ROSE is by design broadly accessible to those without a formal compiler background. This paper details the interactions between testing of applications and the ways in which compiler technology can aid in the understanding of those applications. We emphasize the particular aspects of ROSE, such as support for the general analysis of whole programs, that are particularly well-suited to the testing research community and the scale of the problems that community solves.

  14. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  15. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  16. Radiographic detection of single-leg fracture in Björk-Shiley Convexo-Concave prosthetic valves: a phantom model study.

    Science.gov (United States)

    Gilchrist, I C; Cardella, J F; Fox, P S; Pae, W E; el-Ghamry Sabe, A A; Landis, J R; Localio, A R; Kunselman, A R; Hopper, K D

    1997-02-01

    Cineradiography can identify patients with single-leg fractured Björk-Shiley Convexo-Concave valves, although little is known about the sensitivity and specificity of this technique. We evaluated three normal and six (0 microm gap) single-leg fractured Björk-Shiley valves that were placed in a working phantom model. Valves were randomly imaged a total of 33 times and duplicated into a 120-valve series with a 1:9 ratio of abnormal/normal valves. Six reviewers independently graded each valve and demonstrated markedly different rates of identifying the fractured valves. Average sensitivity at the grade that clinically results in valve explanation was 47%. Among the normal valves, a correct identification was made 96% (range 91% to 99%) of the time. Present radiographic technology may have significant difficulty in identifying true single-leg fracture in Björk-Shiley valves with limb separations that are common among clinically explanted valves.

  17. Regulatory and technical reports compilation for 1980

    International Nuclear Information System (INIS)

    Oliu, W.E.; McKenzi, L.

    1981-04-01

    This compilation lists formal regulatory and technical reports and conference proceedings issued in 1980 by the US Nuclear Regulatory Commission. The compilation is divided into four major sections. The first major section consists of a sequential listing of all NRC reports in report-number order. The second major section of this compilation consists of a key-word index to report titles. The third major section contains an alphabetically arranged listing of contractor report numbers cross-referenced to their corresponding NRC report numbers. Finally, the fourth section is an errata supplement

  18. Python based high-level synthesis compiler

    Science.gov (United States)

    Cieszewski, Radosław; Pozniak, Krzysztof; Romaniuk, Ryszard

    2014-11-01

    This paper presents a python based High-Level synthesis (HLS) compiler. The compiler interprets an algorithmic description of a desired behavior written in Python and map it to VHDL. FPGA combines many benefits of both software and ASIC implementations. Like software, the mapped circuit is flexible, and can be reconfigured over the lifetime of the system. FPGAs therefore have the potential to achieve far greater performance than software as a result of bypassing the fetch-decode-execute operations of traditional processors, and possibly exploiting a greater level of parallelism. Creating parallel programs implemented in FPGAs is not trivial. This article describes design, implementation and first results of created Python based compiler.

  19. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  20. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  1. Compilation Techniques Specific for a Hardware Cryptography-Embedded Multimedia Mobile Processor

    Directory of Open Access Journals (Sweden)

    Masa-aki FUKASE

    2007-12-01

    Full Text Available The development of single chip VLSI processors is the key technology of ever growing pervasive computing to answer overall demands for usability, mobility, speed, security, etc. We have so far developed a hardware cryptography-embedded multimedia mobile processor architecture, HCgorilla. Since HCgorilla integrates a wide range of techniques from architectures to applications and languages, one-sided design approach is not always useful. HCgorilla needs more complicated strategy, that is, hardware/software (H/S codesign. Thus, we exploit the software support of HCgorilla composed of a Java interface and parallelizing compilers. They are assumed to be installed in servers in order to reduce the load and increase the performance of HCgorilla-embedded clients. Since compilers are the essence of software's responsibility, we focus in this article on our recent results about the design, specifications, and prototyping of parallelizing compilers for HCgorilla. The parallelizing compilers are composed of a multicore compiler and a LIW compiler. They are specified to abstract parallelism from executable serial codes or the Java interface output and output the codes executable in parallel by HCgorilla. The prototyping compilers are written in Java. The evaluation by using an arithmetic test program shows the reasonability of the prototyping compilers compared with hand compilers.

  2. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  3. A symmetric safety valve

    International Nuclear Information System (INIS)

    Burtraw, Dallas; Palmer, Karen; Kahn, Danny

    2010-01-01

    How to set policy in the presence of uncertainty has been central in debates over climate policy. Concern about costs has motivated the proposal for a cap-and-trade program for carbon dioxide, with a 'safety valve' that would mitigate against spikes in the cost of emission reductions by introducing additional emission allowances into the market when marginal costs rise above the specified allowance price level. We find two significant problems, both stemming from the asymmetry of an instrument that mitigates only against a price increase. One is that most important examples of price volatility in cap-and-trade programs have occurred not when prices spiked, but instead when allowance prices collapsed. Second, a single-sided safety valve may have unintended consequences for investment. We illustrate that a symmetric safety valve provides environmental and welfare improvements relative to the conventional one-sided approach.

  4. Vectorization vs. compilation in query execution

    NARCIS (Netherlands)

    J. Sompolski (Juliusz); M. Zukowski (Marcin); P.A. Boncz (Peter)

    2011-01-01

    textabstractCompiling database queries into executable (sub-) programs provides substantial benefits comparing to traditional interpreted execution. Many of these benefits, such as reduced interpretation overhead, better instruction code locality, and providing opportunities to use SIMD

  5. Gravity Data for Indiana (300 records compiled)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The gravity data (300 records) were compiled by Purdue University. This data base was received in February 1993. Principal gravity parameters include Free-air...

  6. A Compilation of Internship Reports - 2012

    Energy Technology Data Exchange (ETDEWEB)

    Stegman M.; Morris, M.; Blackburn, N.

    2012-08-08

    This compilation documents all research project undertaken by the 2012 summer Department of Energy - Workforce Development for Teachers and Scientists interns during their internship program at Brookhaven National Laboratory.

  7. ALGOL compiler. Syntax and semantic analysis

    International Nuclear Information System (INIS)

    Tarbouriech, Robert

    1971-01-01

    In this research thesis, the author reports the development of an ALGOL compiler which performs the main following tasks: systematic scan of the origin-programme to recognise the different components (identifiers, reserved words, constants, separators), analysis of the origin-programme structure to build up its statements and arithmetic expressions, processing of symbolic names (identifiers) to associate them with values they represent, and memory allocation for data and programme. Several issues are thus addressed: characteristics of the machine for which the compiler is developed, exact definition of the language (grammar, identifier and constant formation), syntax processing programme to provide the compiler with necessary elements (language vocabulary, precedence matrix), description of the first two phases of compilation: lexicographic analysis, and syntax analysis. The last phase (machine-code generation) is not addressed

  8. A software methodology for compiling quantum programs

    Science.gov (United States)

    Häner, Thomas; Steiger, Damian S.; Svore, Krysta; Troyer, Matthias

    2018-04-01

    Quantum computers promise to transform our notions of computation by offering a completely new paradigm. To achieve scalable quantum computation, optimizing compilers and a corresponding software design flow will be essential. We present a software architecture for compiling quantum programs from a high-level language program to hardware-specific instructions. We describe the necessary layers of abstraction and their differences and similarities to classical layers of a computer-aided design flow. For each layer of the stack, we discuss the underlying methods for compilation and optimization. Our software methodology facilitates more rapid innovation among quantum algorithm designers, quantum hardware engineers, and experimentalists. It enables scalable compilation of complex quantum algorithms and can be targeted to any specific quantum hardware implementation.

  9. Compilation of Instantaneous Source Functions for Varying ...

    African Journals Online (AJOL)

    Compilation of Instantaneous Source Functions for Varying Architecture of a Layered Reservoir with Mixed Boundaries and Horizontal Well Completion Part III: B-Shaped Architecture with Vertical Well in the Upper Layer.

  10. Compilation of Instantaneous Source Functions for Varying ...

    African Journals Online (AJOL)

    Compilation of Instantaneous Source Functions for Varying Architecture of a Layered Reservoir with Mixed Boundaries and Horizontal Well Completion Part IV: Normal and Inverted Letter 'h' and 'H' Architecture.

  11. An Efficient Compiler for Weighted Rewrite Rules

    OpenAIRE

    Mohri, Mehryar; Sproat, Richard

    1996-01-01

    Context-dependent rewrite rules are used in many areas of natural language and speech processing. Work in computational phonology has demonstrated that, given certain conditions, such rewrite rules can be represented as finite-state transducers (FSTs). We describe a new algorithm for compiling rewrite rules into FSTs. We show the algorithm to be simpler and more efficient than existing algorithms. Further, many of our applications demand the ability to compile weighted rules into weighted FST...

  12. Compilation of Sandia Laboratories technical capabilities

    International Nuclear Information System (INIS)

    Lundergan, C.D.; Mead, P.L.

    1975-11-01

    This report is a compilation of 17 individual documents that together summarize the technical capabilities of Sandia Laboratories. Each document in this compilation contains details about a specific area of capability. Examples of application of the capability to research and development problems are provided. An eighteenth document summarizes the content of the other seventeen. Each of these documents was issued with a separate report number (SAND 74-0073A through SAND 74-0091, except -0078)

  13. Compilation of Sandia Laboratories technical capabilities

    Energy Technology Data Exchange (ETDEWEB)

    Lundergan, C. D.; Mead, P. L. [eds.

    1975-11-01

    This report is a compilation of 17 individual documents that together summarize the technical capabilities of Sandia Laboratories. Each document in this compilation contains details about a specific area of capability. Examples of application of the capability to research and development problems are provided. An eighteenth document summarizes the content of the other seventeen. Each of these documents was issued with a separate report number (SAND 74-0073A through SAND 74-0091, except -0078). (RWR)

  14. Electronic circuits for communications systems: A compilation

    Science.gov (United States)

    1972-01-01

    The compilation of electronic circuits for communications systems is divided into thirteen basic categories, each representing an area of circuit design and application. The compilation items are moderately complex and, as such, would appeal to the applications engineer. However, the rationale for the selection criteria was tailored so that the circuits would reflect fundamental design principles and applications, with an additional requirement for simplicity whenever possible.

  15. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  16. A Language for Specifying Compiler Optimizations for Generic Software

    Energy Technology Data Exchange (ETDEWEB)

    Willcock, Jeremiah J. [Indiana Univ., Bloomington, IN (United States)

    2007-01-01

    Compiler optimization is important to software performance, and modern processor architectures make optimization even more critical. However, many modern software applications use libraries providing high levels of abstraction. Such libraries often hinder effective optimization — the libraries are difficult to analyze using current compiler technology. For example, high-level libraries often use dynamic memory allocation and indirectly expressed control structures, such as iteratorbased loops. Programs using these libraries often cannot achieve an optimal level of performance. On the other hand, software libraries have also been recognized as potentially aiding in program optimization. One proposed implementation of library-based optimization is to allow the library author, or a library user, to define custom analyses and optimizations. Only limited systems have been created to take advantage of this potential, however. One problem in creating a framework for defining new optimizations and analyses is how users are to specify them: implementing them by hand inside a compiler is difficult and prone to errors. Thus, a domain-specific language for librarybased compiler optimizations would be beneficial. Many optimization specification languages have appeared in the literature, but they tend to be either limited in power or unnecessarily difficult to use. Therefore, I have designed, implemented, and evaluated the Pavilion language for specifying program analyses and optimizations, designed for library authors and users. These analyses and optimizations can be based on the implementation of a particular library, its use in a specific program, or on the properties of a broad range of types, expressed through concepts. The new system is intended to provide a high level of expressiveness, even though the intended users are unlikely to be compiler experts.

  17. Valve spindle gland

    International Nuclear Information System (INIS)

    Burda, Z.; Harazim, A.; Kerlin, K.

    1979-01-01

    A gland is proposed of the valve spindle designed for radioactive or otherwise harmful media, such as in nuclear power plant primary circuits. The gland is installed in the valve cover and consists of a primary and a secondary part and of a gland case partitioning the gland space into two chambers. The bottom face of the gland case is provided with a double-sided collar for controlling the elements of the bottom primary gland while the top face is provided with a removable flange. (M.S.)

  18. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  19. Fabrication of Microfluidic Valves Using a Hydrogel Molding Method.

    Science.gov (United States)

    Sugiura, Yusuke; Hirama, Hirotada; Torii, Toru

    2015-08-24

    In this paper, a method for fabricating a microfluidic valve made of polydimethylsiloxane (PDMS) using a rapid prototyping method for microchannels through hydrogel cast molding is discussed. Currently, the valves in microchannels play an important role in various microfluidic devices. The technology to prototype microfluidic valves rapidly is actively being developed. For the rapid prototyping of PDMS microchannels, a method that uses a hydrogel as the casting mold has been recently developed. This technique can be used to prepare a three-dimensional structure through simple and uncomplicated methods. In this study, we were able to fabricate microfluidic valves easily using this rapid prototyping method that utilizes hydrogel cast molding. In addition, we confirmed that the valve displacement could be predicted within a range of constant pressures. Moreover, because microfluidic valves fabricated using this method can be directly observed from a cross-sectional direction, we anticipate that this technology will significantly contribute to clarifying fluid behavior and other phenomena in microchannels and microfluidic valves with complex structures.

  20. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  1. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  2. Deep knowledge and knowledge compilation for dynamic systems

    International Nuclear Information System (INIS)

    Mizoguchi, Riichiro

    1994-01-01

    Expert systems are viewed as knowledge-based systems which efficiently solve real-world problems based on the expertise contained in their knowledge bases elicited from domain experts. Although such expert systems that depends on heuristics of domain experts have contributed to the current success, they are known to be brittle and hard to build. This paper is concerned with research on model-based diagnosis and knowledge compilation for dynamic systems conducted by the author's group to overcome these difficulties. Firstly, we summarize the advantages and shortcomings of expert systems. Secondly, deep knowledge and knowledge compilation is discussed. Then, latest results of our research on model-based diagnosis is overviewed. The future direction of knowledge base technology research is also discussed. (author)

  3. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly r...

  4. Heart valve surgery - discharge

    Science.gov (United States)

    ... ACC guideline for the management of patients with valvular heart disease: executive summary: a report of the American College ... Editorial team. Related MedlinePlus Health Topics Heart Surgery Heart Valve Diseases Browse the Encyclopedia A.D.A.M., Inc. ...

  5. Poppet valve tester

    Science.gov (United States)

    Tellier, G. F.

    1973-01-01

    Tester investigates fundamental factors affecting cyclic life and sealing performance of valve seats and poppets. Tester provides for varying impact loading of poppet against seat and rate of cycling, and controls amount and type of relative motion between sealing faces of seat and poppet. Relative motion between seat and poppet can be varied in three modes.

  6. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  7. Blocked Urethral Valves

    Science.gov (United States)

    ... if any damage has occurred to the upper urinary tract. Your pediatrician will consult with a pediatric nephrologist (kidney specialist) or nurologist, who may recommend surgery to remove the obstructing valves and prevent further infection or damage to the kidneys or urinary system. ...

  8. SULIVAN: Remote Manual Valve Monitoring System Real-Time Transmission of Valve Positions to Reduce Alignment Errors

    Energy Technology Data Exchange (ETDEWEB)

    Denis, J.C.; Mace, J.R.; Perisse, J.

    2015-07-01

    Every year, a number of plants worldwide face valve misalignment issues that can lead to damaged components and unplanned extended outage. By installing valve monitoring solutions, the plant can expect a reduction of the risk of valve misalignment events. Over the past years, AREVA has developed Wireless communication solutions and Smart sensor expertise at its own facilities and has carried out tests in nuclear power plants. This paper presents AREVA Wireless studies and Solutions that could be implemented in a nuclear plant. These solutions are mainly based on IoT technologies as MEMs and Low Power Wide Area Network, LPWAN. (Author)

  9. SULIVAN: Remote Manual Valve Monitoring System Real-Time Transmission of Valve Positions to Reduce Alignment Errors

    International Nuclear Information System (INIS)

    Denis, J.C.; Mace, J.R.; Perisse, J.

    2015-01-01

    Every year, a number of plants worldwide face valve misalignment issues that can lead to damaged components and unplanned extended outage. By installing valve monitoring solutions, the plant can expect a reduction of the risk of valve misalignment events. Over the past years, AREVA has developed Wireless communication solutions and Smart sensor expertise at its own facilities and has carried out tests in nuclear power plants. This paper presents AREVA Wireless studies and Solutions that could be implemented in a nuclear plant. These solutions are mainly based on IoT technologies as MEMs and Low Power Wide Area Network, LPWAN. (Author)

  10. Tricuspid valve endocarditis

    Science.gov (United States)

    Hussain, Syed T.; Witten, James; Shrestha, Nabin K.; Blackstone, Eugene H.

    2017-01-01

    Right-sided infective endocarditis (RSIE) is less common than left-sided infective endocarditis (IE), encompassing only 5–10% of cases of IE. Ninety percent of RSIE involves the tricuspid valve (TV). Given the relatively small numbers of TVIE cases operated on at most institutions, the purpose of this review is to highlight and discuss the current understanding of IE involving the TV. RSIE and TVIE are strongly associated with intravenous drug use (IVDU), although pacemaker leads, defibrillator leads and vascular access for dialysis are also major risk factors. Staphylococcus aureus is the predominant causative organism in TVIE. Most patients with TVIE are successfully treated with antibiotics, however, 5–16% of RSIE cases eventually require surgical intervention. Indications and timing for surgery are less clear than for left-sided IE; surgery is primarily considered for failed medical therapy, large vegetations and septic pulmonary embolism, and less often for TV regurgitation and heart failure. Most patients with an infected prosthetic TV will require surgery. Concomitant left-sided IE has its own surgical indications. Earlier surgical intervention may potentially prevent further destruction of leaflet tissue and increase the likelihood of TV repair. Fortunately, TV debridement and repair can be accomplished in most cases, even those with extensive valve destruction, using a variety of techniques. Valve repair is advocated over replacement, particularly in IVDUs patients who are young, non-compliant and have a higher risk of recurrent infection and reoperation with valve replacement. Excising the valve without replacing, it is not advocated; it has been reported previously, but these patients are likely to be symptomatic, particularly in cases with septic pulmonary embolism and increased pulmonary vascular resistance. Patients with concomitant left-sided involvement have worse prognosis than those with RSIE alone, due predominantly to greater likelihood of

  11. Compiling software for a hierarchical distributed processing system

    Science.gov (United States)

    Archer, Charles J; Blocksome, Michael A; Ratterman, Joseph D; Smith, Brian E

    2013-12-31

    Compiling software for a hierarchical distributed processing system including providing to one or more compiling nodes software to be compiled, wherein at least a portion of the software to be compiled is to be executed by one or more nodes; compiling, by the compiling node, the software; maintaining, by the compiling node, any compiled software to be executed on the compiling node; selecting, by the compiling node, one or more nodes in a next tier of the hierarchy of the distributed processing system in dependence upon whether any compiled software is for the selected node or the selected node's descendents; sending to the selected node only the compiled software to be executed by the selected node or selected node's descendent.

  12. New safety valve addresses environmental concerns

    International Nuclear Information System (INIS)

    Taylor, J.; Austin, R.

    1992-01-01

    This paper reports that Conoco Pipeline is using a unique relief valve to reduce costs while improving environmental protection at its facilities. Conoco Pipeline Co. Inc. began testing new relief valves in 1987 to present over-pressuring its pipelines while enhancing the safety, environmental integrity and profitability of its pipelines. Conoco worked jointly with Rupture Pin Technology Inc., Oklahoma City, to seek a solution to a series of safety, environmental, and operational risks in the transportation of crude oil and refined products through pipelines. Several of the identified problems were traced to a single equipment source: the reliability of rupture discs used at pipeline stations to relieve pressure by diverting flow to tanks during over-pressure conditions. Conoco's corporate safety and environmental policies requires solving problems that deal with exposure to hydrocarbon vapors, chemical spills or the atmospheric release of fugitive emissions, such as during rupture disc maintenance. The company had used rupture pin valves as vent relief devices in conjunction with development by Rick Austin of inert gas methods to protect the inner casing wall and outer carrier pipeline wall in pipeline road crossings. The design relies on rupture pin valves set at 5 psi to isolate vent openings from the atmosphere prior to purging the annular space between the pipeline and casing with inert gas to prevent corrosion. Speciality Pipeline Inspection and Engineering Inc., Houston, is licensed to distribute the equipment for the new cased-crossing procedure

  13. Analysis of electromagnetic field of direct action solenoid valve with current changing

    International Nuclear Information System (INIS)

    Liu Qianfeng; Bo Hanliang; Qin Benke

    2009-01-01

    Control rod hydraulic drive mechanism(CRHDM) is a newly invented patent of Institute of Nuclear and New Energy Technology of Tsinghua University. The direct action solenoid valve is the key part of this technology, so the performance of the solenoid valve directly affects the function of the CRHDM. With the current and the air gap changing,the electromagnetic field of the direct action solenoid valve was analyzed using the ANSYS software,which was validated by the experiment. The result shows that the electromagnetic force of the solenoid valve increases with the current increasing or the gap between the two armatures decreasing. Further more, the working current was confirmed. (authors)

  14. Compilations and evaluations of nuclear structure and decay data

    International Nuclear Information System (INIS)

    Lorenz, A.

    1977-10-01

    This is the third issue of a report series on published and to-be-published compilations and evaluations of nuclear structure and decay (NSD) data. This compilation is published and distributed by the IAEA Nuclear Data Section approximately every six months. This compilation of compilations and evaluations is designed to keep the nuclear scientific community informed of the availability of compiled or evaluated NSD data, and contains references to laboratory reports, journal articles and books containing selected compilations and evaluations

  15. Compilation of data on elementary particles

    International Nuclear Information System (INIS)

    Trippe, T.G.

    1984-09-01

    The most widely used data compilation in the field of elementary particle physics is the Review of Particle Properties. The origin, development and current state of this compilation are described with emphasis on the features which have contributed to its success: active involvement of particle physicists; critical evaluation and review of the data; completeness of coverage; regular distribution of reliable summaries including a pocket edition; heavy involvement of expert consultants; and international collaboration. The current state of the Review and new developments such as providing interactive access to the Review's database are described. Problems and solutions related to maintaining a strong and supportive relationship between compilation groups and the researchers who produce and use the data are discussed

  16. Automatic Loop Parallelization via Compiler Guided Refactoring

    DEFF Research Database (Denmark)

    Larsen, Per; Ladelsky, Razya; Lidman, Jacob

    For many parallel applications, performance relies not on instruction-level parallelism, but on loop-level parallelism. Unfortunately, many modern applications are written in ways that obstruct automatic loop parallelization. Since we cannot identify sufficient parallelization opportunities...... for these codes in a static, off-line compiler, we developed an interactive compilation feedback system that guides the programmer in iteratively modifying application source, thereby improving the compiler’s ability to generate loop-parallel code. We use this compilation system to modify two sequential...... benchmarks, finding that the code parallelized in this way runs up to 8.3 times faster on an octo-core Intel Xeon 5570 system and up to 12.5 times faster on a quad-core IBM POWER6 system. Benchmark performance varies significantly between the systems. This suggests that semi-automatic parallelization should...

  17. Compilation of current high energy physics experiments

    International Nuclear Information System (INIS)

    1978-09-01

    This compilation of current high-energy physics experiments is a collaborative effort of the Berkeley Particle Data Group, the SLAC library, and the nine participating laboratories: Argonne (ANL), Brookhaven (BNL), CERN, DESY, Fermilab (FNAL), KEK, Rutherford (RHEL), Serpukhov (SERP), and SLAC. Nominally, the compilation includes summaries of all high-energy physics experiments at the above laboratories that were approved (and not subsequently withdrawn) before about June 1978, and had not completed taking of data by 1 January 1975. The experimental summaries are supplemented with three indexes to the compilation, several vocabulary lists giving names or abbreviations used, and a short summary of the beams at each of the laboratories (except Rutherford). The summaries themselves are included on microfiche

  18. Extension of Alvis compiler front-end

    Energy Technology Data Exchange (ETDEWEB)

    Wypych, Michał; Szpyrka, Marcin; Matyasik, Piotr, E-mail: mwypych@agh.edu.pl, E-mail: mszpyrka@agh.edu.pl, E-mail: ptm@agh.edu.pl [AGH University of Science and Technology, Department of Applied Computer Science, Al. Mickiewicza 30, 30-059 Krakow (Poland)

    2015-12-31

    Alvis is a formal modelling language that enables possibility of verification of distributed concurrent systems. An Alvis model semantics finds expression in an LTS graph (labelled transition system). Execution of any language statement is expressed as a transition between formally defined states of such a model. An LTS graph is generated using a middle-stage Haskell representation of an Alvis model. Moreover, Haskell is used as a part of the Alvis language and is used to define parameters’ types and operations on them. Thanks to the compiler’s modular construction many aspects of compilation of an Alvis model may be modified. Providing new plugins for Alvis Compiler that support languages like Java or C makes possible using these languages as a part of Alvis instead of Haskell. The paper presents the compiler internal model and describes how the default specification language can be altered by new plugins.

  19. Effect of amusement park rides on programmable shunt valve settings.

    Science.gov (United States)

    Strahle, Jennifer; Collins, Kelly; Stetler, William R; Smith, Brandon W; Garton, Thomas; Garton, Catherine; Garton, Hugh J L; Maher, Cormac O

    2013-01-01

    Magnetically programmable shunt valves are susceptible to environmental factors including magnetic fields and accelerative forces. It is unknown if rollercoasters with or without magnetic brakes or linear induction motors (LIMs) are capable of altering the setting of a programmable shunt valve. Two different valve types (type A, n = 10; type B, n = 9) were tested at varying resistance settings in 2 trials on 6 different amusement park rides including 2 rides with LIMs, 2 rides with magnetic brakes, and 2 rides without magnetic technology. The performance level of valve type A and the setting of valve type B changed on rollercoasters with magnets (A = 2.5% [2/80]; B = 5.6% [4/72]) and without magnets (A = 7.5% [3/40]; B = 2.8% [1/36]). Neither valve setting changed when exposed to a Ferris wheel or during ambulation throughout the park. Magnetically programmable valves are susceptible to changes in pressure settings when exposed to amusement park rides with elevated vertical gravitational forces, irrespective of the presence of LIMs or magnetic brakes. © 2013 S. Karger AG, Basel.

  20. Asian collaboration on nuclear reaction data compilation

    International Nuclear Information System (INIS)

    Aikawa, Masayuki; Furutachi, Naoya; Kato, Kiyoshi; Makinaga, Ayano; Devi, Vidya; Ichinkhorloo, Dagvadorj; Odsuren, Myagmarjav; Tsubakihara, Kohsuke; Katayama, Toshiyuki; Otuka, Naohiko

    2013-01-01

    Nuclear reaction data are essential for research and development in nuclear engineering, radiation therapy, nuclear physics and astrophysics. Experimental data must be compiled in a database and be accessible to nuclear data users. One of the nuclear reaction databases is the EXFOR database maintained by the International Network of Nuclear Reaction Data Centres (NRDC) under the auspices of the International Atomic Energy Agency. Recently, collaboration among the Asian NRDC members is being further developed under the support of the Asia-Africa Science Platform Program of the Japan Society for the Promotion of Science. We report the activity for three years to develop the Asian collaboration on nuclear reaction data compilation. (author)

  1. Promising Compilation to ARMv8 POP

    OpenAIRE

    Podkopaev, Anton; Lahav, Ori; Vafeiadis, Viktor

    2017-01-01

    We prove the correctness of compilation of relaxed memory accesses and release-acquire fences from the "promising" semantics of [Kang et al. POPL'17] to the ARMv8 POP machine of [Flur et al. POPL'16]. The proof is highly non-trivial because both the ARMv8 POP and the promising semantics provide some extremely weak consistency guarantees for normal memory accesses; however, they do so in rather different ways. Our proof of compilation correctness to ARMv8 POP strengthens the results of the Kan...

  2. Compiling knowledge-based systems from KEE to Ada

    Science.gov (United States)

    Filman, Robert E.; Bock, Conrad; Feldman, Roy

    1990-01-01

    The dominant technology for developing AI applications is to work in a multi-mechanism, integrated, knowledge-based system (KBS) development environment. Unfortunately, systems developed in such environments are inappropriate for delivering many applications - most importantly, they carry the baggage of the entire Lisp environment and are not written in conventional languages. One resolution of this problem would be to compile applications from complex environments to conventional languages. Here the first efforts to develop a system for compiling KBS developed in KEE to Ada (trademark). This system is called KATYDID, for KEE/Ada Translation Yields Development Into Delivery. KATYDID includes early prototypes of a run-time KEE core (object-structure) library module for Ada, and translation mechanisms for knowledge structures, rules, and Lisp code to Ada. Using these tools, part of a simple expert system was compiled (not quite automatically) to run in a purely Ada environment. This experience has given us various insights on Ada as an artificial intelligence programming language, potential solutions of some of the engineering difficulties encountered in early work, and inspiration on future system development.

  3. Fault-tolerant digital microfluidic biochips compilation and synthesis

    CERN Document Server

    Pop, Paul; Stuart, Elena; Madsen, Jan

    2016-01-01

    This book describes for researchers in the fields of compiler technology, design and test, and electronic design automation the new area of digital microfluidic biochips (DMBs), and thus offers a new application area for their methods.  The authors present a routing-based model of operation execution, along with several associated compilation approaches, which progressively relax the assumption that operations execute inside fixed rectangular modules.  Since operations can experience transient faults during the execution of a bioassay, the authors show how to use both offline (design time) and online (runtime) recovery strategies. The book also presents methods for the synthesis of fault-tolerant application-specific DMB architectures. ·         Presents the current models used for the research on compilation and synthesis techniques of DMBs in a tutorial fashion; ·         Includes a set of “benchmarks”, which are presented in great detail and includes the source code of most of the t...

  4. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  5. The use of transcatheter aortic valve replacement vs surgical aortic valve replacement for the treatment of aortic stenosis

    Directory of Open Access Journals (Sweden)

    Jensen HA

    2015-08-01

    Full Text Available Hanna A Jensen, Lillian L Tsai, Vinod H Thourani Division of Cardiothoracic Surgery, Joseph B Whitehead Department of Surgery, Structural Heart and Valve Center, Emory University School of Medicine, Atlanta, GA, USA Abstract: Severe aortic stenosis (AS is associated with considerable morbidity and mortality and is increasing in prevalence as the global population increases. Since AS primarily affects the elderly, many of these patients have comorbidities that make them poor candidates for the gold standard treatment for AS, surgical aortic valve replacement. Transcatheter aortic valve replacement has emerged as a novel technology for the management of AS in higher risk patients over the past decade. Randomized trials have established the safety and efficacy of transcatheter aortic valve replacement, and the medical community has rallied to identify the patients who are most suitable for this transformative treatment. This review focuses on outlining the key procedural differences, describing the unique challenges of both operations, and finally assessing and comparing outcomes both on a general level and in challenging patient subgroups. Keywords: aortic valve replacement, transcatheter aortic valve replacement, surgical aortic valve replacement 

  6. Posterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Steve J. Hodges

    2009-01-01

    Full Text Available The most common cause of lower urinary tract obstruction in male infants is posterior urethral valves. Although the incidence has remained stable, the neonatal mortality for this disorder has improved due to early diagnosis and intensive neonatal care, thanks in part to the widespread use of prenatal ultrasound evaluations. In fact, the most common reason for the diagnosis of posterior urethral valves presently is the evaluation of infants for prenatal hydronephrosis. Since these children are often diagnosed early, the urethral obstruction can be alleviated rapidly through catheter insertion and eventual surgery, and their metabolic derangements can be normalized without delay, avoiding preventable infant mortality. Of the children that survive, however, early diagnosis has not had much effect on their long-term prognosis, as 30% still develop renal insufficiency before adolescence. A better understanding of the exact cause of the congenital obstruction of the male posterior urethra, prevention of postnatal bladder and renal injury, and the development of safe methods to treat urethral obstruction prenatally (and thereby avoiding the bladder and renal damage due to obstructive uropathy are the goals for the care of children with posterior urethral valves[1].

  7. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  8. Parallelizing More Loops with Compiler Guided Refactoring

    DEFF Research Database (Denmark)

    Larsen, Per; Ladelsky, Razya; Lidman, Jacob

    2012-01-01

    an interactive compilation feedback system that guides programmers in iteratively modifying their application source code. This helps leverage the compiler’s ability to generate loop-parallel code. We employ our system to modify two sequential benchmarks dealing with image processing and edge detection...

  9. Compilation of information on melter modeling

    International Nuclear Information System (INIS)

    Eyler, L.L.

    1996-03-01

    The objective of the task described in this report is to compile information on modeling capabilities for the High-Temperature Melter and the Cold Crucible Melter and issue a modeling capabilities letter report summarizing existing modeling capabilities. The report is to include strategy recommendations for future modeling efforts to support the High Level Waste (BLW) melter development

  10. Design of methodology for incremental compiler construction

    Directory of Open Access Journals (Sweden)

    Pavel Haluza

    2011-01-01

    Full Text Available The paper deals with possibilities of the incremental compiler construction. It represents the compiler construction possibilities for languages with a fixed set of lexical units and for languages with a variable set of lexical units, too. The methodology design for the incremental compiler construction is based on the known algorithms for standard compiler construction and derived for both groups of languages. Under the group of languages with a fixed set of lexical units there belong languages, where each lexical unit has its constant meaning, e.g., common programming languages. For this group of languages the paper tries to solve the problem of the incremental semantic analysis, which is based on incremental parsing. In the group of languages with a variable set of lexical units (e.g., professional typographic system TEX, it is possible to change arbitrarily the meaning of each character on the input file at any time during processing. The change takes effect immediately and its validity can be somehow limited or is given by the end of the input. For this group of languages this paper tries to solve the problem case when we use macros temporarily changing the category of arbitrary characters.

  11. Compilation of cross-sections. Pt. 1

    International Nuclear Information System (INIS)

    Flaminio, V.; Moorhead, W.G.; Morrison, D.R.O.; Rivoire, N.

    1983-01-01

    A compilation of integral cross-sections for hadronic reactions is presented. This is an updated version of CERN/HERA 79-1, 79-2, 79-3. It contains all data published up to the beginning of 1982, but some more recent data have also been included. Plots of the cross-sections versus incident laboratory momentum are also given. (orig.)

  12. Verified compilation of Concurrent Managed Languages

    Science.gov (United States)

    2017-11-01

    Communications Division Information Directorate This report is published in the interest of scientific and technical information exchange, and its...271, 2007. [85] Viktor Vafeiadis. Modular fine-grained concurrency verification. Technical Report UCAM-CL-TR- 726, University of Cambridge, Computer...VERIFIED COMPILATION OF CONCURRENT MANAGED LANGUAGES PURDUE UNIVERSITY NOVEMBER 2017 FINAL TECHNICAL REPORT APPROVED FOR PUBLIC RELEASE

  13. Nuclear power plant operational data compilation system

    International Nuclear Information System (INIS)

    Silberberg, S.

    1980-01-01

    Electricite de France R and D Division has set up a nuclear power plant operational data compilation system. This data bank, created through American documents allows results about plant operation and operational material behaviour to be given. At present, French units at commercial operation are taken into account. Results obtained after five years of data bank operation are given. (author)

  14. Compiler-Agnostic Function Detection in Binaries

    NARCIS (Netherlands)

    Andriesse, D.A.; Slowinska, J.M.; Bos, H.J.

    2017-01-01

    We propose Nucleus, a novel function detection algorithm for binaries. In contrast to prior work, Nucleus is compiler-agnostic, and does not require any learning phase or signature information. Instead of scanning for signatures, Nucleus detects functions at the Control Flow Graph-level, making it

  15. Compiler Driven Code Comments and Refactoring

    DEFF Research Database (Denmark)

    Larsen, Per; Ladelsky, Razya; Karlsson, Sven

    2011-01-01

    . We demonstrate the ability of our tool to trans- form code, and suggest code refactoring that increase its amenability to optimization. The preliminary results shows that, with our tool-set, au- tomatic loop parallelization with the GNU C compiler, gcc, yields 8.6x best-case speedup over...

  16. Expectation Levels in Dictionary Consultation and Compilation ...

    African Journals Online (AJOL)

    Dictionary consultation and compilation is a two-way engagement between two parties, namely a dictionary user and a lexicographer. How well users cope with looking up words in a Bantu language dictionary and to what extent their expectations are met, depends on their consultation skills, their knowledge of the structure ...

  17. Expectation Levels in Dictionary Consultation and Compilation*

    African Journals Online (AJOL)

    Abstract: Dictionary consultation and compilation is a two-way engagement between two par- ties, namely a dictionary user and a lexicographer. How well users cope with looking up words in a Bantu language dictionary and to what extent their expectations are met, depends on their con- sultation skills, their knowledge of ...

  18. Compilation of cross-sections. Pt. 4

    International Nuclear Information System (INIS)

    Alekhin, S.I.; Ezhela, V.V.; Lugovsky, S.B.; Tolstenkov, A.N.; Yushchenko, O.P.; Baldini, A.; Cobal, M.; Flaminio, V.; Capiluppi, P.; Giacomelli, G.; Mandrioli, G.; Rossi, A.M.; Serra, P.; Moorhead, W.G.; Morrison, D.R.O.; Rivoire, N.

    1987-01-01

    This is the fourth volume in our series of data compilations on integrated cross-sections for weak, electromagnetic, and strong interaction processes. This volume covers data on reactions induced by photons, neutrinos, hyperons, and K L 0 . It contains all data published up to June 1986. Plots of the cross-sections versus incident laboratory momentum are also given. (orig.)

  19. 1991 OCRWM bulletin compilation and index

    International Nuclear Information System (INIS)

    1992-05-01

    The OCRWM Bulletin is published by the Department of Energy, Office of Civilian Radioactive Waste Management, to provide current information about the national program for managing spent fuel and high-level radioactive waste. The document is a compilation of issues from the 1991 calendar year. A table of contents and an index have been provided to reference information contained in this year's Bulletins

  20. Compiling Relational Bayesian Networks for Exact Inference

    DEFF Research Database (Denmark)

    Jaeger, Manfred; Darwiche, Adnan; Chavira, Mark

    2006-01-01

    We describe in this paper a system for exact inference with relational Bayesian networks as defined in the publicly available PRIMULA tool. The system is based on compiling propositional instances of relational Bayesian networks into arithmetic circuits and then performing online inference...

  1. Compiling Relational Bayesian Networks for Exact Inference

    DEFF Research Database (Denmark)

    Jaeger, Manfred; Chavira, Mark; Darwiche, Adnan

    2004-01-01

    We describe a system for exact inference with relational Bayesian networks as defined in the publicly available \\primula\\ tool. The system is based on compiling propositional instances of relational Bayesian networks into arithmetic circuits and then performing online inference by evaluating...

  2. Assessment of diagnostic methods for determining degradation of check valves

    International Nuclear Information System (INIS)

    Haynes, H.D.; Farmer, W.S.

    1992-01-01

    The Oak Ridge National Laboratory (ORNL) has carried out a comprehensive aging assessment of check valves in support of the Nuclear Plant Aging Research (NPAR) program. This paper provides a summary of the ORNL check valve aging assessment with emphasis on the identification, evaluation, and application of check valve monitoring methods and techniques. Several check valve monitoring methods are described and compared. These methods include: acoustic emission monitoring, ultrasonic inspection, magnetic flux signature analysis (MFSA), external magnetics. These diagnostic technologies were shown to be useful in determining check valve condition (e.g., disc position, disc motion, and seat leakage), although none of the methods was by itself, successful in monitoring all three condition indicators. The combination of acoustic emission with either ultrasonics or one of the magnetic technologies, however, yields a monitoring system that succeeds in providing the sensitivity to detect all major check valve operating conditions. Other areas covered in the paper include descriptions of relevant regulatory issues, utility group activities, and interactions ORNL has had with outside organizations for the purpose of disseminating research results

  3. Pros and cons of transcatheter aortic valve implantation (TAVI).

    Science.gov (United States)

    Terré, Juan A; George, Isaac; Smith, Craig R

    2017-09-01

    Transcatheter aortic valve implantation (TAVI) or replacement (TAVR) was recently approved by the FDA for intermediate risk patients with severe aortic stenosis (AS). This technique was already worldwide adopted for inoperable and high-risk patients. Improved device technology, imaging analysis and operator expertise has reduced the initial worrisome higher complications rate associated with TAVR, making it comparable to surgical aortic valve replacement (SAVR). However, many answers need to be addressed before adoption in lower risk patients. This paper highlights the pros and cons of TAVI based mostly on randomized clinical trials involving the two device platforms approved in the United States. We focused our analysis on metrics that will play a key role in expanding TAVR indication in healthier individuals. We review the significance and gave a perspective on paravalvular leak (PVL), valve performance, valve durability, leaflet thrombosis, stroke and pacemaker requirement.

  4. Latest-Generation Transcatheter Aortic Valve Replacement Devices and Procedures.

    Science.gov (United States)

    Chamandi, Chekrallah; Puri, Rishi; Rodriguez-Gabella, Tania; Rodés-Cabau, Josep

    2017-09-01

    Transcatheter aortic valve replacement (TAVR) is a well-established treatment for patients with severe symptomatic aortic stenosis who are at high or prohibitive surgical risk. More recently, TAVR has emerged as a valid alternative to surgical aortic valve replacement for treating intermediate-risk patients, and several studies are currently evaluating the role of TAVR in low-risk patients. Transcatheter heart valve (THV) technologies have evolved considerably over time, and important iterations have been implemented in many of the latest-generation devices to (1) reduce the size and improve delivery system properties; (2) improve valve deployment, repositioning, and retrievability; and (3) reduce paravalvular leaks. This article reviews the main characteristics of, and clinical results associated with, the newer-generation THVs while providing an overview of novel TAVR indications. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  5. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  6. Automatic fire hydrant valve development

    International Nuclear Information System (INIS)

    Drumheller, K.

    1976-01-01

    The development of a remotely-controlled valve to operate a fire hydrant is described. Assembled from off-the-shelf components, the prototype illustrates that a valve light enough to be handled by one man is possible. However, it does not have the ruggedness or reliability needed for actual fire-fighting operations. Preliminary testing by City of Tacoma fire department personnel indicates that the valve may indeed contribute significantly to fire-fighting efficiency

  7. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  8. HAL/S-FC compiler system functional specification

    Science.gov (United States)

    1974-01-01

    Compiler organization is discussed, including overall compiler structure, internal data transfer, compiler development, and code optimization. The user, system, and SDL interfaces are described, along with compiler system requirements. Run-time software support package and restrictions and dependencies are also considered of the HAL/S-FC system.

  9. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  10. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  11. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  12. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  13. Aging and malfunction of valves in CANDU special safety systems. Phase 1

    International Nuclear Information System (INIS)

    1989-03-01

    Aging and wear related valve malfunctions have been reported in American nuclear generating systems. This report documents the first attempt to study these phenomena on a global basis in Canadian nuclear power plants. A general methodology outlines an approach to this type of study which is amenable to use within existing information structures. Nuclear regulatory requirements which influence the testing of valves in Canadian nuclear power plants are reviewed. The reporting systems which emanate from these requirements are discussed and sources of valve failure data are reviewed. It is determined that modifications to existing failure reporting systems are required before practical means of collecting data necessary for the analysis of age related valve malfunctions can be developed. In spite of limitations in reported failure data, a partial data base is compiled for valve failures in Special Safety Systems of domestic nuclear plants. Data are reported for the period 1982 to 1986. The valve population and basic parameters of each valve such as type, operator, function, etc., and the reported failures against this population are compiled and reviewed for evidence of time dependent versus random failure trends. Results suggest that there is no clear age related failure trend. In fact, some systems and stations, experienced a reduction in failure rates with years of servicing, suggesting that some earlier generic valve problems may have been solved. Present inspection, test, and maintenance practices are reviewed and their effectiveness for purposes of predicting or preventing incipient failures is assessed to be of moderate value. Modern failure prevention methods are highlighted and their applicability discussed

  14. Transcatheter aortic valve implantation and cerebrovascular accidents.

    Science.gov (United States)

    Stortecky, Stefan; Wenaweser, Peter; Windecker, Stephan

    2012-09-01

    Transcatheter aortic valve implantation (TAVI) is an evidence-based treatment alternative for selected high-risk patients with symptomatic severe aortic stenosis as acknowledged in the most recent edition of the ESC Guidelines on Valvular Heart Disease 2012. However, periprocedural complications and in particular cerebrovascular accidents remain a matter of concern. While transcatheter heart valve technology continuously improves and the development of novel and even less invasive implantation techniques is on-going, cerebrovascular events complicating TAVI may abrogate the usual improvement in terms of prognosis and quality of life. This article describes the incidence of cerebrovascular events after cardiovascular procedures, provides an overview of the pathophysiological mechanisms as well as the impact on outcomes and provides some insights into preventive strategies as well as the acute management of these events.

  15. Reliability estimation for check valves and other components

    International Nuclear Information System (INIS)

    McElhaney, K.L.; Staunton, R.H.

    1996-01-01

    For years the nuclear industry has depended upon component operational reliability information compiled from reliability handbooks and other generic sources as well as private databases generated by recognized experts both within and outside the nuclear industry. Regrettably, these technical bases lacked the benefit of large-scale operational data and comprehensive data verification, and did not take into account the parameters and combinations of parameters that affect the determination of failure rates. This paper briefly examines the historic use of generic component reliability data, its sources, and its limitations. The concept of using a single failure rate for a particular component type is also examined. Particular emphasis is placed on check valves due to the information available on those components. The Appendix presents some of the results of the extensive analyses done by Oak Ridge National Laboratory (ORNL) on check valve performance

  16. Heart Valve Surgery Recovery and Follow Up

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Heart Valves • Heart Valve Problems and Causes • Risks, Signs and Symptoms • Accurate Diagnosis • Treatment Options • Recovery and ...

  17. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  18. Perspex machine: V. Compilation of C programs

    Science.gov (United States)

    Spanner, Matthew P.; Anderson, James A. D. W.

    2006-01-01

    The perspex machine arose from the unification of the Turing machine with projective geometry. The original, constructive proof used four special, perspective transformations to implement the Turing machine in projective geometry. These four transformations are now generalised and applied in a compiler, implemented in Pop11, that converts a subset of the C programming language into perspexes. This is interesting both from a geometrical and a computational point of view. Geometrically, it is interesting that program source can be converted automatically to a sequence of perspective transformations and conditional jumps, though we find that the product of homogeneous transformations with normalisation can be non-associative. Computationally, it is interesting that program source can be compiled for a Reduced Instruction Set Computer (RISC), the perspex machine, that is a Single Instruction, Zero Exception (SIZE) computer.

  19. Compilation of data from hadronic atoms

    International Nuclear Information System (INIS)

    Poth, H.

    1979-01-01

    This compilation is a survey of the existing data of hadronic atoms (pionic-atoms, kaonic-atoms, antiprotonic-atoms, sigmonic-atoms). It collects measurements of the energies, intensities and line width of X-rays from hadronic atoms. Averaged values for each hadronic atom are given and the data are summarized. The listing contains data on 58 pionic-atoms, on 54 kaonic-atoms, on 23 antiprotonic-atoms and on 20 sigmonic-atoms. (orig./HB) [de

  20. A compilation of subsurface hydrogeologic data

    International Nuclear Information System (INIS)

    1986-03-01

    This report presents a compilation of both fracture properties and hydrogeological parameters relevant to the flow of groundwater in fractured rock systems. Methods of data acquisition as well as the scale of and conditions during the measurement are recorded. Measurements and analytical techniques for each of the parameters under consideration have been reviewed with respect to their methodology, assumptions and accuracy. Both the rock type and geologic setting associated with these measurements have also been recorded. 373 refs

  1. Testing of valves and associated systems in large scale experiments

    International Nuclear Information System (INIS)

    Becker, M.

    1985-01-01

    The system examples dealt with are selected so that they cover a wide spectrum of technical tasks and limits. Therefore the flowing medium varies from pure steam flow via a mixed flow of steam and water to pure water flow. The valves concerned include those whose main function is opening, and also those whose main function is the secure closing. There is a certain limitation in that the examples are taken from Boiling Water Reactor technology. The main procedure in valve and system testing described is, of course, not limited to the selected examples, but applies generally in powerstation and process technology. (orig./HAG) [de

  2. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    mortality were collected. Group analysis by patient geographic distribution and by annular diameter of the prosthesis utilized was conducted. Patients with a manufacturer's labeled prosthesis size > or = 21 mm were assigned to the 'large' aortic size subset, while those with a prosthesis size ... differences in the distribution of either gender or BSA. In the multivariable model, south European patients were seven times more likely to receive a smaller-sized aortic valve (OR = 6.5, 95% CI = 4.82-8.83, p

  3. Materials and methods for hard-facing of power engineering valves

    International Nuclear Information System (INIS)

    Frumin, I.I.; Gladkii, P.V.; Eremeev, V.B.; Perepliotchikov, E.F.

    1980-01-01

    In the Soviet Union a large experience in hard-facing for the water and steam valves has been accumulated. A workability of valves largely depends upon materials used and a technology of their deposition. Mechanized methods have been recently successfully developed, new hard-facing materials created are considered

  4. Optimum design of seat region in valves suitable for digital displacement machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital displacement fluid power is an upcoming technology setting new standards for the achievable efficiency in variable displacement fluid power pumps and motors. In the present work, an annular seat valve suitable for use in digital displacement units is considered, and the valve geometry...

  5. Proceedings of the 2nd symposium on valves for coal conversion and utilization

    Energy Technology Data Exchange (ETDEWEB)

    Maxfield, D.A. (ed.)

    1981-01-01

    The 2nd symposium on valves for coal conversion and utilization was held October 15 to 17, 1980. It was sponsored by the US Department of Energy, Morgantown Energy Technology Center, in cooperation with the Valve Manufacturers Association. Seventeen papers have been entered individually into EDB and ERA. (LTN)

  6. BNGS B valve packing program

    International Nuclear Information System (INIS)

    Cumming, D.

    1995-01-01

    The Bruce B Valve Packing Program began in 1987. The early history and development were presented at the 1992 International CANDU Maintenance conference. This presentation covers the evolution of the Bruce B Valve Packing Program over the period 1992 to 1995. (author)

  7. The tightness of the globe valves in the exploitations practice of the gas pipe-lines

    International Nuclear Information System (INIS)

    Pietrak, T.; Rudzki, Z.; Surmacz, W.

    2006-01-01

    Technological units of the Transit Gas Pipeline (i.e. Compressor Stations, Valve Stations, Stations or National Network Service Installations) have been fitted with Ball Valves as shut-off devices (block valves). Internal tightness of the valves' seat becomes major factor in securing proper service conditions during normal pipeline operation as well as for isolating of pipeline sections in emergency situations (loss of pipeline integrity or uncontrolled gas escape). Internal tightness of the valves is being inspected during scheduled maintenance of the pipeline units. Any leak revealed during inspection is being repaired, following instructions provided in the Manufacturer's Valve Manual. After a time, some cases have been identified, when repair of the revealed leak was found to be difficult, despite close following of the repair manuals. The paper presents analysis of the issue and corrective actions taken accordingly. (authors)

  8. Mechanism study of freeze-valve for molten salt reactor (MSR)

    International Nuclear Information System (INIS)

    Qinhua, Zhang

    2014-01-01

    Molten salt reactor (MSR) is one of the fourth generation nuclear reactor, ordinary nuclear grade valve is unsuitable for MSR due to its special coolant and extraordinary working temperature. Freeze-valve is proposed as the most appropriate valve for MSR, but the technology issue about freeze-valve has not been report in recent decades. Its significance to test the comprehensive property of freeze-valve for the application in MSR. A high temperature molten salt test loop was built which the physics property of salt is similar to the coolant of MSR. The results indicate that freeze-valve has a good performance use in the molten salt circumstances of high temperature (max 700 deg. C) and strong corrosion (authors)

  9. Spin valve sensor for biomolecular identification: Design, fabrication, and characterization

    Science.gov (United States)

    Li, Guanxiong

    Biomolecular identification, e.g., DNA recognition, has broad applications in biology and medicine such as gene expression analysis, disease diagnosis, and DNA fingerprinting. Therefore, we have been developing a magnetic biodetection technology based on giant magnetoresistive spin valve sensors and magnetic nanoparticle (developed for the magnetic nanoparticle detection, assuming the equivalent average field of magnetic nanoparticles and the coherent rotation of spin valve free layer magnetization. Micromagnetic simulations have also been performed for the spin valve sensors. The analytical model and micromagnetic simulations are found consistent with each other and are in good agreement with experiments. The prototype spin valve sensors have been fabricated at both micron and submicron scales. We demonstrated the detection of a single 2.8-mum magnetic microbead by micron-sized spin valve sensors. Based on polymer-mediated self-assembly and fine lithography, a bilayer lift-off process was developed to deposit magnetic nanoparticles onto the sensor surface in a controlled manner. With the lift-off deposition method, we have successfully demonstrated the room temperature detection of monodisperse 16-nm Fe3O 4 nanoparticles in a quantity from a few tens to several hundreds by submicron spin valve sensors, proving the feasibility of the nanoparticle detection. As desired for quantitative biodetection, a fairly linear dependence of sensor signal on the number of nanoparticles has been confirmed. The initial detection of DNA hybridization events labeled by magnetic nanoparticles further proved the magnetic biodetection concept.

  10. Investigation of a rotary valving system with variable valve timing for internal combustion engines

    Science.gov (United States)

    Cross, Paul C.; Hansen, Craig N.

    1994-11-01

    The objective of the program was to provide a functional demonstration of the Hansen Rotary Valving System with Variable Valve Timing (HRVS/VVT), capable of throttleless inlet charge control, as an alternative to conventional poppet-valves for use in spark ignited internal combustion engines. The goal of this new technology is to secure benefits in fuel economy, broadened torque band, vibration reduction, and overhaul accessibility. Additionally, use of the variable valve timing capability to vary the effective compression ratio is expected to improve multifuel tolerance and efficiency. Efforts directed at the design of HRVS components proved to be far more extensive than had been anticipated, ultimately requiring that proof-trial design/development work be performed. Although both time and funds were exhausted before optical or ion-probe types of in-cylinder investigation could be undertaken, a great deal of laboratory data was acquired during the course of the design/development work. This laboratory data is the basis for the information presented in this final report.

  11. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  12. Study of laser cladding nuclear valve parts

    International Nuclear Information System (INIS)

    Shi Shihong; Wang Xinlin; Huang Guodong

    1998-12-01

    The mechanism of laser cladding is discussed by using heat transfer model of laser cladding, heat conduction model of laser cladding and convective transfer mass model of laser melt-pool. Subsequently the laser cladding speed limit and the influence of laser cladding parameters on cladding layer structure is analyzed. A 5 kW with CO 2 transverse flow is used in the research for cladding treatment of sealing surface of stop valve parts of nuclear power stations. The laser cladding layer is found to be 3.0 mm thick. The cladding surface is smooth and has no such defects as crack, gas pore, etc. A series of comparisons with plasma spurt welding and arc bead welding has been performed. The results show that there are higher grain grade and hardness, lower dilution and better performances of resistance to abrasion, wear and of anti-erosion in the laser cladding layer. The new technology of laser cladding can obviously improve the quality of nuclear valve parts. Consequently it is possible to lengthen the service life of nuclear valve and to raise the safety and reliability of the production system

  13. Minimally Invasive Cardiac Surgery: Transapical Aortic Valve Replacement

    Directory of Open Access Journals (Sweden)

    Ming Li

    2012-01-01

    Full Text Available Minimally invasive cardiac surgery is less traumatic and therefore leads to quicker recovery. With the assistance of engineering technologies on devices, imaging, and robotics, in conjunction with surgical technique, minimally invasive cardiac surgery will improve clinical outcomes and expand the cohort of patients that can be treated. We used transapical aortic valve implantation as an example to demonstrate that minimally invasive cardiac surgery can be implemented with the integration of surgical techniques and engineering technologies. Feasibility studies and long-term evaluation results prove that transapical aortic valve implantation under MRI guidance is feasible and practical. We are investigating an MRI compatible robotic surgical system to further assist the surgeon to precisely deliver aortic valve prostheses via a transapical approach. Ex vivo experimentation results indicate that a robotic system can also be employed in in vivo models.

  14. A new compiler for the GANIL Data Acquisition description

    International Nuclear Information System (INIS)

    Saillant, F.; Raine, B.

    1997-01-01

    An important feature of the GANIL Data Acquisition System is the description of the experiments by means of a language developed at GANIL. The philosophy is to attribute to each element (parameters, spectra, etc) an operational name which will be used at any level of the system. This language references a library of modules to free the user from the technical details of the hardware. This compiler has been recently entirely re-developed using technologies as the object-oriented language (C++) and object-oriented software development method and tool. This enables us to provide a new functionality or to support a new electronic module within a very short delay and without any deep modification of the application. A new Dynamic Library of Modules has been also developed. Its complete description is available on the GANIL WEB site http://ganinfo.in2p3.fr/acquisition/homepage.html. This new compiler brings a lot of new functionalities, among which the most important is the notion of 'register' whatever the module standard is. All the registers described in the module provider's documentation can now be accessed by their names. Another important new feature is the notion of 'function' that can be executed on a module. Also a set of new instructions has been implemented to execute commands on CAMAC crates. Another possibility of this new compiler is to enable the description of specific interfaces with GANIL Data Acquisition System. This has been used to describe the coupling of the CHIMERA Data Acquisition System with the INDRA one through a shared memory in the VME crate. (authors)

  15. Combining Compile-Time and Run-Time Parallelization

    Directory of Open Access Journals (Sweden)

    Sungdo Moon

    1999-01-01

    Full Text Available This paper demonstrates that significant improvements to automatic parallelization technology require that existing systems be extended in two ways: (1 they must combine high‐quality compile‐time analysis with low‐cost run‐time testing; and (2 they must take control flow into account during analysis. We support this claim with the results of an experiment that measures the safety of parallelization at run time for loops left unparallelized by the Stanford SUIF compiler’s automatic parallelization system. We present results of measurements on programs from two benchmark suites – SPECFP95 and NAS sample benchmarks – which identify inherently parallel loops in these programs that are missed by the compiler. We characterize remaining parallelization opportunities, and find that most of the loops require run‐time testing, analysis of control flow, or some combination of the two. We present a new compile‐time analysis technique that can be used to parallelize most of these remaining loops. This technique is designed to not only improve the results of compile‐time parallelization, but also to produce low‐cost, directed run‐time tests that allow the system to defer binding of parallelization until run‐time when safety cannot be proven statically. We call this approach predicated array data‐flow analysis. We augment array data‐flow analysis, which the compiler uses to identify independent and privatizable arrays, by associating predicates with array data‐flow values. Predicated array data‐flow analysis allows the compiler to derive “optimistic” data‐flow values guarded by predicates; these predicates can be used to derive a run‐time test guaranteeing the safety of parallelization.

  16. An Object-Oriented Approach to C++ Compiler Technology

    NARCIS (Netherlands)

    Sminchisescu, Cristian; Telea, Alexandru

    1999-01-01

    This paper focuses on the use of object-oriented approaches to syntactical and semantical analysis for complex object-oriented languages like C++. We are interested in these issues both from a design and implementation point of view. We implement a semantic analyzer in an object-oriented manner,

  17. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  18. Notes on Compiling a Corpus- Based Dictionary

    Directory of Open Access Journals (Sweden)

    František Čermák

    2011-10-01

    Full Text Available

    ABSTRACT: On the basis of sample analysis of a Czech adjective, a definition based on the data drawn from the Czech National Corpus (cf. Čermák and Schmiedtová 2003 is gradually compiled and finally offered, pointing at the drawbacks of definitions found in traditional dictionaries. Steps undertaken here are then generalized and used, in an ordered sequence (similar to a work-flow ordering, as topics, briefly discussed in the second part to which lexicographers of monolingual dictionaries should pay attention. These are supplemented by additional remarks and caveats useful in the compilation of a dictionary. Thus, a brief survey of some of the major steps of dictionary compilation is presented here, supplemented by the original Czech data, analyzed in their raw, though semiotically classified form.

    OPSOMMING: Aantekeninge oor die samestelling van 'n korpusgebaseerde woordeboek. Op grond van 'n steekproefontleding van 'n Tsjeggiese adjektief, word 'n definisie gebaseer op data ontleen aan die Tsjeggiese Nasionale Korpus (cf. Čermák en Schmiedtová 2003 geleidelik saamgestel en uiteindelik aangebied wat wys op die gebreke van definisies aangetref in tradisionele woordeboeke. Stappe wat hier onderneem word, word dan veralgemeen en gebruik in 'n geordende reeks (soortgelyk aan 'n werkvloeiordening, as onderwerpe, kortliks bespreek in die tweede deel, waaraan leksikograwe van eentalige woordeboeke aandag behoort te gee. Hulle word aangevul deur bykomende opmerkings en waarskuwings wat nuttig is vir die samestelling van 'n woordeboek. Op dié manier word 'n kort oorsig van sommige van die hoofstappe van woordeboeksamestelling hier aangebied, aangevul deur die oorspronklike Tsjeggiese data, ontleed in hul onbewerkte, alhoewel semioties geklassifiseerde vorm.

    Sleutelwoorde: EENTALIGE WOORDEBOEKE, KORPUSLEKSIKOGRAFIE, SINTAGMATIEK EN PARADIGMATIEK IN WOORDEBOEKE, WOORDEBOEKINSKRYWING, SOORTE LEMMAS, PRAGMATIEK, BEHANDELING VAN

  19. Evaluation of HAL/S language compilability using SAMSO's Compiler Writing System (CWS)

    Science.gov (United States)

    Feliciano, M.; Anderson, H. D.; Bond, J. W., III

    1976-01-01

    NASA/Langley is engaged in a program to develop an adaptable guidance and control software concept for spacecraft such as shuttle-launched payloads. It is envisioned that this flight software be written in a higher-order language, such as HAL/S, to facilitate changes or additions. To make this adaptable software transferable to various onboard computers, a compiler writing system capability is necessary. A joint program with the Air Force Space and Missile Systems Organization was initiated to determine if the Compiler Writing System (CWS) owned by the Air Force could be utilized for this purpose. The present study explores the feasibility of including the HAL/S language constructs in CWS and the effort required to implement these constructs. This will determine the compilability of HAL/S using CWS and permit NASA/Langley to identify the HAL/S constructs desired for their applications. The study consisted of comparing the implementation of the Space Programming Language using CWS with the requirements for the implementation of HAL/S. It is the conclusion of the study that CWS already contains many of the language features of HAL/S and that it can be expanded for compiling part or all of HAL/S. It is assumed that persons reading and evaluating this report have a basic familiarity with (1) the principles of compiler construction and operation, and (2) the logical structure and applications characteristics of HAL/S and SPL.

  20. Compilation of accident statistics in PSE

    International Nuclear Information System (INIS)

    Jobst, C.

    1983-04-01

    The objective of the investigations on transportation carried out within the framework of the 'Project - Studies on Safety in Waste Management (PSE II)' is the determination of the risk of accidents in the transportation of radioactive materials by rail. The fault tree analysis is used for the determination of risks in the transportation system. This method offers a possibility for the determination of frequency and consequences of accidents which could lead to an unintended release of radionuclides. The study presented compiles all data obtained from the accident statistics of the Federal German Railways. (orig./RB) [de

  1. HAL/S-360 compiler system specification

    Science.gov (United States)

    Johnson, A. E.; Newbold, P. N.; Schulenberg, C. W.; Avakian, A. E.; Varga, S.; Helmers, P. H.; Helmers, C. T., Jr.; Hotz, R. L.

    1974-01-01

    A three phase language compiler is described which produces IBM 360/370 compatible object modules and a set of simulation tables to aid in run time verification. A link edit step augments the standard OS linkage editor. A comprehensive run time system and library provide the HAL/S operating environment, error handling, a pseudo real time executive, and an extensive set of mathematical, conversion, I/O, and diagnostic routines. The specifications of the information flow and content for this system are also considered.

  2. Compiling the First Monolingual Lusoga Dictionary

    Directory of Open Access Journals (Sweden)

    Minah Nabirye

    2011-10-01

    Full Text Available

    Abstract: In this research article a study is made of the approach followed to compile the first-ever monolingual dictionary for Lusoga. Lusoga is a Bantu language spoken in Uganda by slightly over two mil-lion people. Being an under-resourced language, the Lusoga orthography had to be designed, a grammar written, and a corpus built, before embarking on the compilation of the dictionary. This compilation was aimed at attaining an academic degree, hence requiring a rigorous research methodology. Firstly, the prevail-ing methods for compiling dictionaries were mainly practical and insufficient in explaining the theoretical linguistic basis for dictionary compilation. Since dictionaries are based on meaning, the theory of meaning was used to account for all linguistic data considered in dictionaries. However, meaning is considered at a very abstract level, far removed from the process of compiling dictionaries. Another theory, the theory of modularity, was used to bridge the gap between the theory of meaning and the compilation process. The modular theory explains how the different modules of a language contribute information to the different parts of the dictionary article or dictionary information in general. Secondly, the research also had to contend with the different approaches for analysing Bantu languages for Bantu and European audiences. A descrip-tion of the Bantu- and European-centred approaches to Bantu studies was undertaken in respect of (a the classification of Lusoga words, and (b the specification of their citations. As a result, Lusoga lexicography deviates from the prevailing Bantu classification and citation of nouns, adjectives and verbs in particular. The dictionary was tested on two separate occasions and all the feedback was considered in the compilation pro-cess. This article, then, gives an overall summary of all the steps involved in the compilation of the Eiwanika ly'Olusoga, i.e. the Monolingual Lusoga Dictionary

  3. abc: An extensible AspectJ compiler

    DEFF Research Database (Denmark)

    Avgustinov, Pavel; Christensen, Aske Simon; Hendren, Laurie

    2005-01-01

    checking and code generation, as well as data flow and control flow analyses. The AspectBench Compiler (abc) is an implementation of such a workbench. The base version of abc implements the full AspectJ language. Its frontend is built, using the Polyglot framework, as a modular extension of the Java...... language. The use of Polyglot gives flexibility of syntax and type checking. The backend is built using the Soot framework, to give modular code generation and analyses. In this paper, we outline the design of abc, focusing mostly on how the design supports extensibility. We then provide a general overview...

  4. Compilation of actinide neutron nuclear data

    International Nuclear Information System (INIS)

    1979-01-01

    The Swedish nuclear data committee has compiled a selected set of neutron cross section data for the 16 most important actinide isotopes. The aim of the report is to present available data in a comprehensible way to allow a comparison between different evaluated libraries and to judge about the reliability of these libraries from the experimental data. The data are given in graphical form below about 1 ev and above about 10 keV shile the 2200 m/s cross sections and resonance integrals are given in numerical form. (G.B.)

  5. Data compilation for particle impact desorption

    International Nuclear Information System (INIS)

    Oshiyama, Takashi; Nagai, Siro; Ozawa, Kunio; Takeuchi, Fujio.

    1984-05-01

    The desorption of gases from solid surfaces by incident electrons, ions and photons is one of the important processes of hydrogen recycling in the controlled thermonuclear reactors. We have surveyed the literature concerning the particle impact desorption published through 1983 and compiled the data on the desorption cross sections and desorption yields with the aid of a computer. This report presents the results obtained for electron stimulated desorption, the desorption cross sections and yields being given in graphs and tables as functions of incident electron energy, surface temperature and gas exposure. (author)

  6. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  7. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  8. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  9. 3D printed mitral valve models: affordable simulation for robotic mitral valve repair.

    Science.gov (United States)

    Premyodhin, Ned; Mandair, Divneet; Ferng, Alice S; Leach, Timothy S; Palsma, Ryan P; Albanna, Mohammad Z; Khalpey, Zain I

    2018-01-01

    3D printed mitral valve (MV) models that capture the suture response of real tissue may be utilized as surgical training tools. Leveraging clinical imaging modalities, 3D computerized modelling and 3D printing technology to produce affordable models complements currently available virtual simulators and paves the way for patient- and pathology-specific preoperative rehearsal. We used polyvinyl alcohol, a dissolvable thermoplastic, to 3D print moulds that were casted with liquid platinum-cure silicone yielding flexible, low-cost MV models capable of simulating valvular tissue. Silicone-moulded MV models were fabricated for 2 morphologies: the normal MV and the P2 flail. The moulded valves were plication and suture tested in a laparoscopic trainer box with a da Vinci Si robotic surgical system. One cardiothoracic surgery fellow and 1 attending surgeon qualitatively evaluated the ability of the valves to recapitulate tissue feel through surveys utilizing the 5-point Likert-type scale to grade impressions of the valves. Valves produced with the moulding and casting method maintained anatomical dimensions within 3% of directly 3D printed acrylonitrile butadiene styrene controls for both morphologies. Likert-type scale mean scores corresponded with a realistic material response to sutures (5.0/5), tensile strength that is similar to real MV tissue (5.0/5) and anatomical appearance resembling real MVs (5.0/5), indicating that evaluators 'agreed' that these aspects of the model were appropriate for training. Evaluators 'somewhat agreed' that the overall model durability was appropriate for training (4.0/5) due to the mounting design. Qualitative differences in repair quality were notable between fellow and attending surgeon. 3D computer-aided design, 3D printing and fabrication techniques can be applied to fabricate affordable, high-quality educational models for technical training that are capable of differentiating proficiency levels among users. © The Author 2017

  10. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  11. National Energy Strategy: A compilation of public comments; Interim Report

    Energy Technology Data Exchange (ETDEWEB)

    1990-04-01

    This Report presents a compilation of what the American people themselves had to say about problems, prospects, and preferences in energy. The Report draws on the National Energy Strategy public hearing record and accompanying documents. In all, 379 witnesses appeared at the hearings to exchange views with the Secretary, Deputy Secretary, and Deputy Under Secretary of Energy, and Cabinet officers of other Federal agencies. Written submissions came from more than 1,000 individuals and organizations. Transcripts of the oral testimony and question-and-answer (Q-and-A) sessions, as well as prepared statements submitted for the record and all other written submissions, form the basis for this compilation. Citations of these sources in this document use a system of identifying symbols explained below and in the accompanying box. The Report is organized into four general subject areas concerning: (1) efficiency in energy use, (2) the various forms of energy supply, (3) energy and the environment, and (4) the underlying foundations of science, education, and technology transfer. Each of these, in turn, is subdivided into sections addressing specific topics --- such as (in the case of energy efficiency) energy use in the transportation, residential, commercial, and industrial sectors, respectively. 416 refs., 44 figs., 5 tabs.

  12. The FORTRAN NALAP code adapted to a microcomputer compiler

    International Nuclear Information System (INIS)

    Lobo, Paulo David de Castro; Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso

    2010-01-01

    The Nuclear Energy Division of the Institute for Advanced Studies (IEAv) is conducting the TERRA project (TEcnologia de Reatores Rapidos Avancados), Technology for Advanced Fast Reactors project, aimed at a space reactor application. In this work, to attend the TERRA project, the NALAP code adapted to a microcomputer compiler called Compaq Visual Fortran (Version 6.6) is presented. This code, adapted from the light water reactor transient code RELAP 3B, simulates thermal-hydraulic responses for sodium cooled fast reactors. The strategy to run the code in a PC was divided in some steps mainly to remove unnecessary routines, to eliminate old statements, to introduce new ones and also to include extension precision mode. The source program was able to solve three sample cases under conditions of protected transients suggested in literature: the normal reactor shutdown, with a delay of 200 ms to start the control rod movement and a delay of 500 ms to stop the pumps; reactor scram after transient of loss of flow; and transients protected from overpower. Comparisons were made with results from the time when the NALAP code was acquired by the IEAv, back in the 80's. All the responses for these three simulations reproduced the calculations performed with the CDC compiler in 1985. Further modifications will include the usage of gas as coolant for the nuclear reactor to allow a Closed Brayton Cycle Loop - CBCL - to be used as a heat/electric converter. (author)

  13. The FORTRAN NALAP code adapted to a microcomputer compiler

    Energy Technology Data Exchange (ETDEWEB)

    Lobo, Paulo David de Castro; Borges, Eduardo Madeira; Braz Filho, Francisco Antonio; Guimaraes, Lamartine Nogueira Frutuoso, E-mail: plobo.a@uol.com.b, E-mail: eduardo@ieav.cta.b, E-mail: fbraz@ieav.cta.b, E-mail: guimarae@ieav.cta.b [Instituto de Estudos Avancados (IEAv/CTA), Sao Jose dos Campos, SP (Brazil)

    2010-07-01

    The Nuclear Energy Division of the Institute for Advanced Studies (IEAv) is conducting the TERRA project (TEcnologia de Reatores Rapidos Avancados), Technology for Advanced Fast Reactors project, aimed at a space reactor application. In this work, to attend the TERRA project, the NALAP code adapted to a microcomputer compiler called Compaq Visual Fortran (Version 6.6) is presented. This code, adapted from the light water reactor transient code RELAP 3B, simulates thermal-hydraulic responses for sodium cooled fast reactors. The strategy to run the code in a PC was divided in some steps mainly to remove unnecessary routines, to eliminate old statements, to introduce new ones and also to include extension precision mode. The source program was able to solve three sample cases under conditions of protected transients suggested in literature: the normal reactor shutdown, with a delay of 200 ms to start the control rod movement and a delay of 500 ms to stop the pumps; reactor scram after transient of loss of flow; and transients protected from overpower. Comparisons were made with results from the time when the NALAP code was acquired by the IEAv, back in the 80's. All the responses for these three simulations reproduced the calculations performed with the CDC compiler in 1985. Further modifications will include the usage of gas as coolant for the nuclear reactor to allow a Closed Brayton Cycle Loop - CBCL - to be used as a heat/electric converter. (author)

  14. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  15. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  16. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  17. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  18. Valve radio and audio repair handbook

    CERN Document Server

    MILLER, CHAS

    2000-01-01

    This book is not only an essential read for every professional working with antique radio and gramophone equipment, but also dealers, collectors and valve technology enthusiasts the world over. The emphasis is firmly on the practicalities of repairing and restoring, so technical content is kept to a minimum, and always explained in a way that can be followed by readers with no background in electronics. Those who have a good grounding in electronics, but wish to learn more about the practical aspects, will benefit from the emphasis given to hands-on repair work, covering mechanical as

  19. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  20. Compiling models into real-time systems

    International Nuclear Information System (INIS)

    Dormoy, J.L.; Cherriaux, F.; Ancelin, J.

    1992-08-01

    This paper presents an architecture for building real-time systems from models, and model-compiling techniques. This has been applied for building a real-time model-based monitoring system for nuclear plants, called KSE, which is currently being used in two plants in France. We describe how we used various artificial intelligence techniques for building it: a model-based approach, a logical model of its operation, a declarative implementation of these models, and original knowledge-compiling techniques for automatically generating the real-time expert system from those models. Some of those techniques have just been borrowed from the literature, but we had to modify or invent other techniques which simply did not exist. We also discuss two important problems, which are often underestimated in the artificial intelligence literature: size, and errors. Our architecture, which could be used in other applications, combines the advantages of the model-based approach with the efficiency requirements of real-time applications, while in general model-based approaches present serious drawbacks on this point

  1. Regular expressions compiler and some applications

    International Nuclear Information System (INIS)

    Saldana A, H.

    1978-01-01

    We deal with high level programming language of a Regular Expressions Compiler (REC). The first chapter is an introduction in which the history of the REC development and the problems related to its numerous applicatons are described. The syntactic and sematic rules as well as the language features are discussed just after the introduction. Concerning the applicatons as examples, an adaptation is given in order to solve numerical problems and another for the data manipulation. The last chapter is an exposition of ideas and techniques about the compiler construction. Examples of the adaptation to numerical problems show the applications to education, vector analysis, quantum mechanics, physics, mathematics and other sciences. The rudiments of an operating system for a minicomputer are the examples of the adaptation to symbolic data manipulaton. REC is a programming language that could be applied to solve problems in almost any human activity. Handling of computer graphics, control equipment, research on languages, microprocessors and general research are some of the fields in which this programming language can be applied and developed. (author)

  2. Compiling models into real-time systems

    International Nuclear Information System (INIS)

    Dormoy, J.L.; Cherriaux, F.; Ancelin, J.

    1992-08-01

    This paper presents an architecture for building real-time systems from models, and model-compiling techniques. This has been applied for building a real-time model-base monitoring system for nuclear plants, called KSE, which is currently being used in two plants in France. We describe how we used various artificial intelligence techniques for building it: a model-based approach, a logical model of its operation, a declarative implementation of these models, and original knowledge-compiling techniques for automatically generating the real-time expert system from those models. Some of those techniques have just been borrowed from the literature, but we had to modify or invent other techniques which simply did not exist. We also discuss two important problems, which are often underestimated in the artificial intelligence literature: size, and errors. Our architecture, which could be used in other applications, combines the advantages of the model-based approach with the efficiency requirements of real-time applications, while in general model-based approaches present serious drawbacks on this point

  3. Scientific Programming with High Performance Fortran: A Case Study Using the xHPF Compiler

    Directory of Open Access Journals (Sweden)

    Eric De Sturler

    1997-01-01

    Full Text Available Recently, the first commercial High Performance Fortran (HPF subset compilers have appeared. This article reports on our experiences with the xHPF compiler of Applied Parallel Research, version 1.2, for the Intel Paragon. At this stage, we do not expect very High Performance from our HPF programs, even though performance will eventually be of paramount importance for the acceptance of HPF. Instead, our primary objective is to study how to convert large Fortran 77 (F77 programs to HPF such that the compiler generates reasonably efficient parallel code. We report on a case study that identifies several problems when parallelizing code with HPF; most of these problems affect current HPF compiler technology in general, although some are specific for the xHPF compiler. We discuss our solutions from the perspective of the scientific programmer, and presenttiming results on the Intel Paragon. The case study comprises three programs of different complexity with respect to parallelization. We use the dense matrix-matrix product to show that the distribution of arrays and the order of nested loops significantly influence the performance of the parallel program. We use Gaussian elimination with partial pivoting to study the parallelization strategy of the compiler. There are various ways to structure this algorithm for a particular data distribution. This example shows how much effort may be demanded from the programmer to support the compiler in generating an efficient parallel implementation. Finally, we use a small application to show that the more complicated structure of a larger program may introduce problems for the parallelization, even though all subroutines of the application are easy to parallelize by themselves. The application consists of a finite volume discretization on a structured grid and a nested iterative solver. Our case study shows that it is possible to obtain reasonably efficient parallel programs with xHPF, although the compiler

  4. Sterilization and preservation for aortic-valve transplantation

    NARCIS (Netherlands)

    A.W.M. van der Kamp (Arthur)

    1976-01-01

    textabstractRecent advances in modern technology1 expertise and surgical enterprise hove contributed to the solution of may problems in the field of cardiovascular and thoracic surgery. Among these the surgical treatment of heart-valvedysfunctionby valve replacement has become possible

  5. 12 CFR 411.600 - Semi-annual compilation.

    Science.gov (United States)

    2010-01-01

    ... 12 Banks and Banking 4 2010-01-01 2010-01-01 false Semi-annual compilation. 411.600 Section 411.600 Banks and Banking EXPORT-IMPORT BANK OF THE UNITED STATES NEW RESTRICTIONS ON LOBBYING Agency Reports § 411.600 Semi-annual compilation. (a) The head of each agency shall collect and compile the...

  6. Compilation of functional languages using flow graph analysis

    NARCIS (Netherlands)

    Hartel, Pieter H.; Glaser, Hugh; Wild, John M.

    A system based on the notion of a flow graph is used to specify formally and to implement a compiler for a lazy functional language. The compiler takes a simple functional language as input and generates C. The generated C program can then be compiled, and loaded with an extensive run-time system to

  7. Transcatheter Pulmonary Valve Replacement: Current State of Art.

    Science.gov (United States)

    Alkashkari, Wail; Alsubei, Amani; Hijazi, Ziyad M

    2018-03-15

    The past couple of decades have brought tremendous advances to the field of pediatric and adult congenital heart disease (CHD). Percutaneous valve interventions are now a cornerstone of not just the congenital cardiologist treating patients with congenital heart disease, but also-and numerically more importantly-for adult interventional cardiologists treating patients with acquired heart valve disease. Transcatheter pulmonary valve replacement (tPVR) is one of the most exciting recent developments in the treatment of CHD and has evolved to become an attractive alternative to surgery in patients with right ventricular outflow tract (RVOT) dysfunction. This review aims to summarize (1) the current state of the art for tPVR, (2) the expanding indications, and (3) the technological obstacles to optimizing tPVR. Since its introduction in 2000, more than ten thousands tPVR procedures have been performed worldwide. Although the indications for tPVR have been adapted earlier from those accepted for surgical intervention, they remain incompletely defined. The new imaging modalities give better assessment of cardiac anatomy and function and determine candidacy for the procedure. The procedure has been shown to be feasible and safe when performed in patients who received pulmonary conduit and or bioprosthetic valves between the right ventricle and the pulmonary artery. Fewer selected patients post trans-annular patch repair for tetralogy of Fallot may also be candidates for this technology. Size restrictions of the currently available valves limit deployment in the majority of patients post trans-annular patch repair. Newer valves and techniques are being developed that may help such patients. Refinements and further developments of this procedure hold promise for the extension of this technology to other patient populations.

  8. Options for Heart Valve Replacement

    Science.gov (United States)

    ... Guide: Understanding Your Heart Valve Problem | Spanish Symptom Tracker | Spanish Pre-surgery Checklist | Spanish What Is Heart ... Cardiac Arrest: How Are They Different? 7 Warning Signs of a Heart Attack 8 Low Blood Pressure - ...

  9. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  10. Substitution of cobalt alloying in PWR primary circuit gate valves

    International Nuclear Information System (INIS)

    Cachon, L.; Sudreau, F.; Brunel, L.

    1995-01-01

    The object of this study is qualify cobalt-free alternative alloys for valve applications. This paper focus on tribological characterization of numerous coatings is done by using the first one, of a classical type. Then tests are performed with the second one which simulates solicitations supported by gate valves in primary circuit of PWR. 35% Ni-Cr - 65% Cr 3 C 2 coating, deposited by detonation gun technology, gives us hope to find a substitute of Stelite 6. (author). 5 refs., 16 figs., 2 tabs

  11. Discussion on the compilation of document of iso quality management system for radiation sterilization enterprises

    International Nuclear Information System (INIS)

    Li Chunhong; Ha Yiming; Zhou Hongjie; Feng Zhiguo; Wang Feng

    2006-01-01

    According to the character of cooperation of radiation sterilization, and association with request of ISO9001, ISO13485 and ISO11137, compilation of document in quality manual, procedure document and technological document during certification of ISO quality management system of cooperation of radiation sterilization was discussed. (authors)

  12. Statistical Compilation of the ICT Sector and Policy Analysis | Page 4 ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Statistical Compilation of the ICT Sector and Policy Analysis. As the presence and influence of information and communication technologies (ICTs) continues to widen and deepen, so too does its impact on economic development. However, much work needs to be done before the linkages between economic development ...

  13. Statistical Compilation of the ICT Sector and Policy Analysis | Page 3 ...

    International Development Research Centre (IDRC) Digital Library (Canada)

    Statistical Compilation of the ICT Sector and Policy Analysis. As the presence and influence of information and communication technologies (ICTs) continues to widen and deepen, so too does its impact on economic development. However, much work needs to be done before the linkages between economic development ...

  14. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  15. Optimization of geometry of annular seat valves suitable for Digital Displacement fluid power pumps/motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    Digital Displacement Fluid Power is an upcoming technology setting new standards for the achievable efficiency of fluid power pumps and motors. The core element of the Digital Displacement technology is high performance electronically controlled seat valves, which must exhibit very low flow...... work an annular seat valve suitable for use in Digital Displacement units is considered, and the ring geometry is optimized using finite element analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting the actual load of the seat valve...

  16. WHO GLOBAL TUBERCULOSIS REPORTS: COMPILATION AND INTERPRETATION

    Directory of Open Access Journals (Sweden)

    I. A. Vаsilyevа

    2017-01-01

    Full Text Available The purpose of the article is to inform national specialists involved in tuberculosis control about methods for compilation of WHO global tuberculosis statistics, which are used when developing strategies and programmes for tuberculosis control and evaluation of their efficiency.  The article explains in detail the notions of main WHO epidemiological rates, used in the international publications on tuberculosis along with the data on their registered values, new approaches to making the list of country with the highest burden of tuberculosis, drug resistant tuberculosis and tuberculosis with concurrent HIV infection. The article compares the rates in the Russian Federation with global data as well as data from countries within WHO European Regions and countries with highest TB burden. It presents materials on the achievement of Global goals in tuberculosis control and main provisions of WHO End TB Strategy for 2015-2035 adopted as a part of UNO Sustainable Development Goals.  

  17. JLAPACK – Compiling LAPACK FORTRAN to Java

    Directory of Open Access Journals (Sweden)

    David M. Doolin

    1999-01-01

    Full Text Available The JLAPACK project provides the LAPACK numerical subroutines translated from their subset Fortran 77 source into class files, executable by the Java Virtual Machine (JVM and suitable for use by Java programmers. This makes it possible for Java applications or applets, distributed on the World Wide Web (WWW to use established legacy numerical code that was originally written in Fortran. The translation is accomplished using a special purpose Fortran‐to‐Java (source‐to‐source compiler. The LAPACK API will be considerably simplified to take advantage of Java’s object‐oriented design. This report describes the research issues involved in the JLAPACK project, and its current implementation and status.

  18. Molecular dynamics and diffusion a compilation

    CERN Document Server

    Fisher, David

    2013-01-01

    The molecular dynamics technique was developed in the 1960s as the outgrowth of attempts to model complicated systems by using either a) direct physical simulation or (following the great success of Monte Carlo methods) by b) using computer techniques. Computer simulation soon won out over clumsy physical simulation, and the ever-increasing speed and sophistication of computers has naturally made molecular dynamics simulation into a more and more successful technique. One of its most popular applications is the study of diffusion, and some experts now even claim that molecular dynamics simulation is, in the case of situations involving well-characterised elements and structures, more accurate than experimental measurement. The present double volume includes a compilation (over 600 items) of predicted solid-state diffusion data, for all of the major materials groups, dating back nearly four decades. The double volume also includes some original papers: "Determination of the Activation Energy for Formation and ...

  19. From the ground up: building a minimally invasive aortic valve surgery program

    OpenAIRE

    Nguyen, Tom C.; Lamelas, Joseph

    2015-01-01

    Minimally invasive aortic valve replacement (MIAVR) is associated with numerous advantages including improved patient satisfaction, cosmesis, decreased transfusion requirements, and cost-effectiveness. Despite these advantages, little information exists on how to build a MIAVR program from the ground up. The steps to build a MIAVR program include compiling a multi-disciplinary team composed of surgeons, cardiologists, anesthesiologists, perfusionists, operating room (OR) technicians, and nurs...

  20. Compilation of requests for nuclear data

    International Nuclear Information System (INIS)

    1983-01-01

    The purpose of this compilation is to summarize the current needs of US Nuclear Energy programs and other applied technolgies for nuclear data. It is the result of a biennial review in which the Department of Energy (DOE) and contractors, Department of Defense Laboratories and contractors, and other interested groups have been asked to review and revise their requests for nuclear data. It was felt that the evaluators of cross section data and the users of these evaluations should be involved in the review of the data requests to make this compilation more useful. This request list is ordered by target nucleus (Isotope) and then reaction type (Quantity). Each request is assigned a unique identifying number. The first two digits of this number give the year the request was initiated. All requests for a given Isotope and Quantity are grouped (or blocked) together. The requests in a block are followed by any status comments. Each request has a unique Isotope, Quantity and Requester. The requester is identified by laboratory, last name, and sponsoring US government agency, e.g., BET, DEI, DNR. All requesters, together with their addresses and phone numbers, are given in appendix B. A list of the evaluators responsible for ENDF/B-V evaluations with their affiliation appears in appendix C. All requests must give the energy (or range of energy) for the incident particle when appropriate. The accuracy needed in percent is also given. The error quoted is assumed to be 1-sigma at each measured point in the energy range requested unless a comment specifies otherwise. Sometimes a range of accuracy indicated by two values is given or some statement is given in the free text comments. An incident particle energy resolution in percent is sometimes given

  1. Compilation of requests for nuclear data

    International Nuclear Information System (INIS)

    Weston, L.W.; Larson, D.C.

    1993-02-01

    This compilation represents the current needs for nuclear data measurements and evaluations as expressed by interested fission and fusion reactor designers, medical users of nuclear data, nuclear data evaluators, CSEWG members and other interested parties. The requests and justifications are reviewed by the Data Request and Status Subcommittee of CSEWG as well as most of the general CSEWG membership. The basic format and computer programs for the Request List were produced by the National Nuclear Data Center (NNDC) at Brookhaven National Laboratory. The NNDC produced the Request List for many years. The Request List is compiled from a computerized data file. Each request has a unique isotope, reaction type, requestor and identifying number. The first two digits of the identifying number are the year in which the request was initiated. Every effort has been made to restrict the notations to those used in common nuclear physics textbooks. Most requests are for individual isotopes as are most ENDF evaluations, however, there are some requests for elemental measurements. Each request gives a priority rating which will be discussed in Section 2, the neutron energy range for which the request is made, the accuracy requested in terms of one standard deviation, and the requested energy resolution in terms of one standard deviation. Also given is the requestor with the comments which were furnished with the request. The addresses and telephone numbers of the requestors are given in Appendix 1. ENDF evaluators who may be contacted concerning evaluations are given in Appendix 2. Experimentalists contemplating making one of the requested measurements are encouraged to contact both the requestor and evaluator who may provide valuable information. This is a working document in that it will change with time. New requests or comments may be submitted to the editors or a regular CSEWG member at any time

  2. Compiler issues associated with safety-related software

    International Nuclear Information System (INIS)

    Feinauer, L.R.

    1991-01-01

    A critical issue in the quality assurance of safety-related software is the ability of the software to produce identical results, independent of the host machine, operating system, or compiler version under which the software is installed. A study is performed using the VIPRE-0l, FREY-01, and RETRAN-02 safety-related codes. Results from an IBM 3083 computer are compared with results from a CYBER 860 computer. All three of the computer programs examined are written in FORTRAN; the VIPRE code uses the FORTRAN 66 compiler, whereas the FREY and RETRAN codes use the FORTRAN 77 compiler. Various compiler options are studied to determine their effect on the output between machines. Since the Control Data Corporation and IBM machines inherently represent numerical data differently, methods of producing equivalent accuracy of data representation were an important focus of the study. This paper identifies particular problems in the automatic double-precision option (AUTODBL) of the IBM FORTRAN 1.4.x series of compilers. The IBM FORTRAN version 2 compilers provide much more stable, reliable compilation for engineering software. Careful selection of compilers and compiler options can help guarantee identical results between different machines. To ensure reproducibility of results, the same compiler and compiler options should be used to install the program as were used in the development and testing of the program

  3. Research and Practice of the News Map Compilation Service

    Science.gov (United States)

    Zhao, T.; Liu, W.; Ma, W.

    2018-04-01

    Based on the needs of the news media on the map, this paper researches on the news map compilation service, conducts demand research on the service of compiling news maps, designs and compiles the public authority base map suitable for media publication, and constructs the news base map material library. It studies the compilation of domestic and international news maps with timeliness and strong pertinence and cross-regional characteristics, constructs the hot news thematic gallery and news map customization services, conducts research on types of news maps, establish closer liaison and cooperation methods with news media, and guides news media to use correct maps. Through the practice of the news map compilation service, this paper lists two cases of news map preparation services used by different media, compares and analyses cases, summarizes the research situation of news map compilation service, and at the same time puts forward outstanding problems and development suggestions in the service of news map compilation service.

  4. Compilations and evaluations of nuclear structure and decay data

    International Nuclear Information System (INIS)

    Lorenz, A.

    1977-03-01

    This is the second issue of a report series on published and to-be-published compilations and evaluations of nuclear structure and decay (NSD) data. This compilation of compilations and evaluations is designed to keep the nuclear scientific community informed of the availability of compiled or evaluated NSD data, and contains references to laboratory reports, journal articles and books containing selected compilations and evaluations. It excludes references to ''mass-chain'' evaluations normally published in the ''Nuclear Data Sheets'' and ''Nuclear Physics''. The material contained in this compilation is sorted according to eight subject categories: general compilations; basic isotopic properties; nuclear structure properties; nuclear decay processes; half-lives, energies and spectra; nuclear decay processes: gamma-rays; nuclear decay processes: fission products; nuclear decay processes: (others); atomic processes

  5. Development of nuclear quality high pressure valve bellows in Canada

    International Nuclear Information System (INIS)

    Janzen, P.; Astill, C.J.

    1978-06-01

    Concurrent with the decision to use bellows stem sealed nuclear valves where feasible in commercial-scale CANDU plants, AECL undertook to develop an indigenous high pressure valve bellows technology. This program included developing the capability to fabricate improved high pressure valve bellows in conjunction with a Canadian manufacturer. This paper describes the evolution of a two-stage bellows fabrication process involving: (1) manufacture of discrete lengths of precision thin wall telescoping tubes - from preparation of strip blanks through edge grinding and edge forming to longitudinal welding; (2) forming of bellows from tube assemblies using a novel combination of mechanical inward forming followed by hydraulic outward forming. Bellows of Inconel 600 and Inconel 625 have been manufactured and evaluated. Test results indicate comparable to improved performance over alternative high quality bellows. (author)

  6. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  7. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  8. Prevention of crack initiation in valve bodies under thermal shock

    Energy Technology Data Exchange (ETDEWEB)

    Delmas, J.; Coppolani, P.

    1996-12-01

    On site and testing experience has shown that cracking in valves affects mainly the stellite hardfacing on seats and discs but may also be a concern for valve bodies. Metallurgical investigations conducted by EDF laboratories on many damaged valves have shown that most of the damage had either a chemical, manufacturing, or operating origin with a strong correlation between the origins and the type of damage. The chemical defects were either excess ferritic dilution of stellite or excess carburizing. Excess carburizing leads to a too brittle hardfacing which cracks under excessive stresses induced on the seating surfaces, via the stem, by too high operating thrusts. The same conditions can also induce cracks of the seats in the presence, in the hardfacing, of hidden defects generated during the welding process. Reduction of the number of defects results first from controls during manufacturing, mainly in the thickness of stellite. On the other hand, maintenance must be fitted to the type of defect. In-situ lapping may lead to release of cobalt, resulting in contamination of the circuit. Furthermore, it is ineffectual in the case of a crack through the seating surface, as is often found on globe valves. The use of new technologies of valves with removable seats and cobalt-free alloys solves permanently this kind of problem.

  9. Development of a novel rf waveguide vacuum valve

    CERN Document Server

    Grudiev, A

    2006-01-01

    The development of a novel rf waveguide vacuum valve is presented. The rf design is based on the use of TE0n modes of circular waveguides. In the device, the TE01 mode at the input is converted into a mixture of several TE0n modes which provide low-loss rf power transmission across the vacuum valve gap, these modes are then converted back into the TE01 mode at the output. There are a number of advantages associated with the absence of surface fields in the region of the valve: • Possibility to use commercially available vacuum valves equipped with two specially designed mode converter sections. • No necessity for an rf contact between these two sections. • Increased potential for high power rf transmission. This technology can be used for all frequencies for which vacuum waveguides are used. In rectangular waveguides, mode converters from the operating mode into the TE01 mode and back again are necessary. Experimental results for the 30 GHz valves developed for the CLIC Test Facility 3 (CTF3) a...

  10. Soft valves in plants

    Science.gov (United States)

    Park, Keunhwan; Tixier, Aude; Christensen, Anneline; Arnbjerg-Nielsen, Sif; Zwieniecki, Maciej; Jensen, Kaare

    2017-11-01

    Water and minerals flow from plant roots to leaves in the xylem, an interconnected network of vascular conduits that spans the full length of the organism. When a plant is subjected to drought stress, air pockets can spread inside the xylem, threatening the survival of the plant. Many plants prevent propagation of air by using hydrophobic nano-membranes in the ``pit'' pores that link adjacent xylem cells. This adds considerable resistance to flow. Interestingly, torus-margo pit pores in conifers are open and offer less resistance. To prevent propagation of air, conifers use a soft gating mechanism, which relies on hydrodynamic interactions between the xylem liquid and the elastic pit. However, it is unknown exactly how it is able to combine the seemingly antagonist functions of high permeability and resistance to propagation of air. We conduct experiments on biomimetic pores to elucidate the flow regulation mechanism. The design of plant valves is compared to other natural systems and optimal strategies are discussed. This work was supported by a research Grant (13166) from VILLUM FONDEN.

  11. Annular flow diverter valve

    International Nuclear Information System (INIS)

    Rider, R.L.

    1980-01-01

    A valve is described for diverting flow from the center of two concentric tubes to the annulus between the tubes or, operating in the reverse direction, for mixing fluids from concentric tubes into a common tube and for controlling the volume ratio of said flow. It consists of a toroidal baffle disposed in sliding engagement with the interior of the inner tube downstream of a plurality of ports in the inner tube, a plurality of gates in sliding engagement with the interior of the inner tube attached to the baffle for movement therewith, a servomotor having a bullet-shaped plug on the downstream end thereof, and drive rods connecting the servomotor to the toroidal baffle. The sevomotor is adapted to move the baffle into mating engagement with the bullet-shaped plug and simultaneously move the gates away from the ports in the inner tube and to move the baffle away from the bullet-shaped plug and simultaneously move the gates to cover the ports in the inner tube

  12. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  13. Transient flow analysis of integrated valve opening process

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xinming; Qin, Benke; Bo, Hanliang, E-mail: bohl@tsinghua.edu.cn; Xu, Xingxing

    2017-03-15

    Highlights: • The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the integrated valve (IV) is the key control component. • The transient flow experiment induced by IV is conducted and the test results are analyzed to get its working mechanism. • The theoretical model of IV opening process is established and applied to get the changing rule of the transient flow characteristic parameters. - Abstract: The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the IV is the key control component. The working principle of integrated valve (IV) is analyzed and the IV hydraulic experiment is conducted. There is transient flow phenomenon in the valve opening process. The theoretical model of IV opening process is established by the loop system control equations and boundary conditions. The valve opening boundary condition equation is established based on the IV three dimensional flow field analysis results and the dynamic analysis of the valve core movement. The model calculation results are in good agreement with the experimental results. On this basis, the model is used to analyze the transient flow under high temperature condition. The peak pressure head is consistent with the one under room temperature and the pressure fluctuation period is longer than the one under room temperature. Furthermore, the changing rule of pressure transients with the fluid and loop structure parameters is analyzed. The peak pressure increases with the flow rate and the peak pressure decreases with the increase of the valve opening time. The pressure fluctuation period increases with the loop pipe length and the fluctuation amplitude remains largely unchanged under different equilibrium pressure conditions. The research results lay the base for the vibration reduction analysis of the CRHDS.

  14. First report on a human percutaneous transluminal implantation of a self-expanding valve prosthesis for interventional treatment of aortic valve stenosis.

    Science.gov (United States)

    Grube, Eberhard; Laborde, Jean C; Zickmann, Bernfried; Gerckens, Ulrich; Felderhoff, Thomas; Sauren, Barthel; Bootsveld, Andreas; Buellesfeld, Lutz; Iversen, Stein

    2005-12-01

    Percutaneous aortic valve replacement is a new technology for the treatment of patients with significant aortic valve stenosis. We present the first report on a human implantation of a self-expanding aortic valve prosthesis, which is composed of three bovine pericardial leaflets inserted within a self-expanding nitinol stent. The 73-year-old woman presented with severe symptomatic aortic valve stenosis (mean transvalvular gradient of 45 mmHg; valve area of 0.7 cm2). Surgical valve replacement had been declined for the patient because of comorbidities, including previous bypass surgery. A retrograde approach via the common iliac artery was used for valve deployment. The contralateral femoral vessels were used for a temporary extracorporal circulation, unloading the left ventricle during the actual stent expansion. Clinical, hemodynamic, and echocardiographic outcomes were assessed serially during the procedure. Clinical and echocardiographic follow-up at day 1, 2, and 14 post procedure was performed to evaluate the short-term outcome. The prosthesis was successfully deployed within the native aortic valve, with accurate and stable positioning and with no impairment of the coronary artery or vein graft blood flow. 2D and doppler echo immediately after device deployment showed a significant reduction in transaortic mean pressure gradient (from 45 to 8 mmHg) without evidence of aortic or mitral valve insufficiency. The clinical status has then significantly improved. These results remained unchanged up to the day 14 follow-up. This case report demonstrates a successful percutaneous implantation of a self-expanding aortic valve prosthesis with remarkable functional and clinical improvements in the acute and short-term outcome. Copyright (c) 2005 Wiley-Liss, Inc.

  15. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  16. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  17. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  18. Experimental study on coil of direct action solenoid valve with temperature increasing

    International Nuclear Information System (INIS)

    Wang Lu; Liu Qianfeng; Bo Hanliang

    2012-01-01

    Hydraulic control rod drive technology (HCRDT) is a newly invented patent and Institute of Nuclear and New Energy Technology of Tsinghua University owns HCRDT's independent intellectual property rights. The integrated valve which is made up of three direct action solenoid valves is the key part of this technology, so the performance of the solenoid valve directly affects the function of the integrated valve and the HCRDT. Based on the conditions occurring in the operation of the control rod hydraulic drive system, the coil of the direct action solenoid valve with temperature increasing was studied by the experiment and analyzed by ANSYS code. The result shows that the temperature of the coil for the solenoid valve increases with the current increasing firstly. The temperature of the inner wall of the coil is higher than that of the exterior wall. The temperature of the middle coil is higher than that of the edge of the coil. The design of the direct action solenoid valve can be optimized. (authors)

  19. Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles

    Science.gov (United States)

    Dunn, V. B.

    1975-01-01

    A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

  20. Design Method for Fast Switching Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    corresponding to the piston movement, which has been shown to facilitate superior part load efficiency combined with high bandwidth compared to traditional displacement machines. However, DD machines need fast switching on-off valves with low pressure loss for efficient operation, especially in fast rotating......Digital Displacement (DD) machines are upcoming technology where the displacement of each pressure chamber is controlled electronically by use of two fast switching seat valves. The effective displacement and operation type (pumping/motoring) may be controlled by manipulating the seat valves...... method for DD seat valves are presented, taking into account the significant aspects related to obtaining efficient DD valves with basis in a given DD machine specifications. The seat area is minimized and the stroke length is minimized to obtain fast switching times while considering the pressure loss...

  1. Real-time three-dimensional transesophageal echocardiography in valve disease: comparison with surgical findings and evaluation of prosthetic valves.

    Science.gov (United States)

    Sugeng, Lissa; Shernan, Stanton K; Weinert, Lynn; Shook, Doug; Raman, Jai; Jeevanandam, Valluvan; DuPont, Frank; Fox, John; Mor-Avi, Victor; Lang, Roberto M

    2008-12-01

    Recently, a novel real-time 3-dimensional (3D) matrix-array transesophageal echocardiographic (3D-MTEE) probe was found to be highly effective in the evaluation of native mitral valves (MVs) and other intracardiac structures, including the interatrial septum and left atrial appendage. However, the ability to visualize prosthetic valves using this transducer has not been evaluated. Moreover, the diagnostic accuracy of this new technology has never been validated against surgical findings. This study was designed to (1) assess the quality of 3D-MTEE images of prosthetic valves and (2) determine the potential value of 3D-MTEE imaging in the preoperative assessment of valvular pathology by comparing images with surgical findings. Eighty-seven patients undergoing clinically indicated transesophageal echocardiography were studied. In 40 patients, 3D-MTEE images of prosthetic MVs, aortic valves (AVs), and tricuspid valves (TVs) were scored for the quality of visualization. For both MVs and AVs, mechanical and bioprosthetic valves, the rings and leaflets were scored individually. In 47 additional patients, intraoperative 3D-MTEE diagnoses of MV pathology obtained before initiating cardiopulmonary bypass were compared with surgical findings. For the visualization of prosthetic MVs and annuloplasty rings, quality was superior compared with AV and TV prostheses. In addition, 3D-MTEE imaging had 96% agreement with surgical findings. Three-dimensional matrix-array transesophageal echocardiographic imaging provides superb imaging and accurate presurgical evaluation of native MV pathology and prostheses. However, the current technology is less accurate for the clinical assessment of AVs and TVs. Fast acquisition and immediate online display will make this the modality of choice for MV surgical planning and postsurgical follow-up.

  2. Compiling quantum circuits to realistic hardware architectures using temporal planners

    Science.gov (United States)

    Venturelli, Davide; Do, Minh; Rieffel, Eleanor; Frank, Jeremy

    2018-04-01

    To run quantum algorithms on emerging gate-model quantum hardware, quantum circuits must be compiled to take into account constraints on the hardware. For near-term hardware, with only limited means to mitigate decoherence, it is critical to minimize the duration of the circuit. We investigate the application of temporal planners to the problem of compiling quantum circuits to newly emerging quantum hardware. While our approach is general, we focus on compiling to superconducting hardware architectures with nearest neighbor constraints. Our initial experiments focus on compiling Quantum Alternating Operator Ansatz (QAOA) circuits whose high number of commuting gates allow great flexibility in the order in which the gates can be applied. That freedom makes it more challenging to find optimal compilations but also means there is a greater potential win from more optimized compilation than for less flexible circuits. We map this quantum circuit compilation problem to a temporal planning problem, and generated a test suite of compilation problems for QAOA circuits of various sizes to a realistic hardware architecture. We report compilation results from several state-of-the-art temporal planners on this test set. This early empirical evaluation demonstrates that temporal planning is a viable approach to quantum circuit compilation.

  3. Application of risk-based methods to inservice testing of check valves

    Energy Technology Data Exchange (ETDEWEB)

    Closky, N.B.; Balkey, K.R.; McAllister, W.J. [and others

    1996-12-01

    Research efforts have been underway in the American Society of Mechanical Engineers (ASME) and industry to define appropriate methods for the application of risk-based technology in the development of inservice testing (IST) programs for pumps and valves in nuclear steam supply systems. This paper discusses a pilot application of these methods to the inservice testing of check valves in the emergency core cooling system of Georgia Power`s Vogtle nuclear power station. The results of the probabilistic safety assessment (PSA) are used to divide the check valves into risk-significant and less-risk-significant groups. This information is reviewed by a plant expert panel along with the consideration of appropriate deterministic insights to finally categorize the check valves into more safety-significant and less safety-significant component groups. All of the more safety-significant check valves are further evaluated in detail using a failure modes and causes analysis (FMCA) to assist in defining effective IST strategies. A template has been designed to evaluate how effective current and emerging tests for check valves are in detecting failures or in finding significant conditions that are precursors to failure for the likely failure causes. This information is then used to design and evaluate appropriate IST strategies that consider both the test method and frequency. A few of the less safety-significant check valves are also evaluated using this process since differences exist in check valve design, function, and operating conditions. Appropriate test strategies are selected for each check valve that has been evaluated based on safety and cost considerations. Test strategies are inferred from this information for the other check valves based on similar check valve conditions. Sensitivity studies are performed using the PSA model to arrive at an overall IST program that maintains or enhances safety at the lowest achievable cost.

  4. Numerical simulation and analysis of ball valve three-dimensional flow based on CFD

    International Nuclear Information System (INIS)

    Zhang, S C; Zhang, Y L; Fang, Z M

    2012-01-01

    The new rotor oil-gas mixture pump that added ball valves in its export is a kind of innovative products, which can better adapt to the oil and gas mixed condition. In order to explore the rule of flow field in the export ball valve of new rotor oil-gas mixture pump, established the 3 d model of ball valve flow field was established. Using the FLUENT software, combining the standard k-ε turbulent model with multiphase flow technology and adopting the SIMPLE algorithm to simulate the 3 d gas-liquid two phase flow field in export ball valve of new rotor oil-gas mixture pump. In the different conditions that the volume of gas rate was 25%, 50%, 75%, through analyzing the velocity field, stress field and the distribution of the liquid and gas with the ball valve open height respectively at 3mm, 5mm, 7mm. Discussed how open height and different volume of gas rate to influence the field in export ball valve in the process of gas-liquid mixing was discussed. The simulation results showed that the greater the open height, the smaller the difference pressure of ball valve; the gap velocity decreasing with the open height increasing. The gas is mainly distributed in the vicinity of the valve ball in the process of gas-liquid mixing. The gas liquid ratio has a little effect on the gap velocity in the same open height. The results showed the flow field forms in the ball valve directly, to a certain degree, it had released the rules of gas-liquid flow in the valve and provided the theoretical guidance for design and optimization of the new rotor oil-gas mixture pump export ball valve.

  5. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  6. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  7. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  8. Cavitation noise from butterfly valves

    International Nuclear Information System (INIS)

    Rahmeyer, W.J.

    1982-01-01

    Cavitation in valves can produce levels of intense noise. It is possible to mathematically express a limit for a design level of cavitation noise in terms of the cavitation parameter sigma. Using the cavitation parameter or limit, it is then possible to calculate the flow conditions at which a design level of cavitation noise will occur. However, the intensity of cavitation increases with the upstream pressure and valve size at a constant sigma. Therefore, it is necessary to derive equations to correct or scale the cavitation limit for the effects of different upstream pressures and valve sizes. The following paper discusses and presents experimental data for the caviation noise limit as well as the cavitation limits of incipient, critical, incipient damage, and choking cavitation for butterfly valves. The main emphasis is on the design limit of caviation noise, and a noise level of 85 decibels was selected as the noise limit. Tables of data and scaling exponents are included for applying the design limits for the effects of upstream pressure and valve size. (orig.)

  9. Plunger with simple retention valve

    International Nuclear Information System (INIS)

    Fekete, A.V.

    1987-01-01

    This patent describes a positive displacement retention valve apparatus in which the actual flow equals the theoretical maximum flow through the retention valve. The apparatus includes, in combination, a confined fluid flow conduit, a piston adapted for reciprocal movement within the fluid flow conduit between upstream and downstream limit positions, piston reciprocating means, and pressure responsive check valve means located upstream with respect to the piston in the fluid flow conduit. The pressure responsive check valve means operable to permit fluid flow therethrough in a downstream direction toward the piston, and to preclude fluid flow therethrough in an opposite direction. The piston is composed of parts which are relatively movable with respect to one another. The piston includes a simple retention valve consisting of a plug means, a cylinder having a minimum and a maximum internal cross section flow area therein and being reciprocal within the confined fluid flow conduit, and a seat on the cylinder for the plug means. The piston reciprocating means are operatively connected to the plug means

  10. Compiling a Monolingual Dictionary for Native Speakers

    Directory of Open Access Journals (Sweden)

    Patrick Hanks

    2011-10-01

    Full Text Available

    ABSTRACT: This article gives a survey of the main issues confronting the compilers of monolingual dictionaries in the age of the Internet. Among others, it discusses the relationship between a lexical database and a monolingual dictionary, the role of corpus evidence, historical principles in lexicography vs. synchronic principles, the instability of word meaning, the need for full vocabulary coverage, principles of definition writing, the role of dictionaries in society, and the need for dictionaries to give guidance on matters of disputed word usage. It concludes with some questions about the future of dictionary publishing.

    OPSOMMING: Die samestelling van 'n eentalige woordeboek vir moedertaalsprekers. Hierdie artikel gee 'n oorsig van die hoofkwessies waarmee die samestellers van eentalige woordeboeke in die eeu van die Internet te kampe het. Dit bespreek onder andere die verhouding tussen 'n leksikale databasis en 'n eentalige woordeboek, die rol van korpusgetuienis, historiese beginsels vs sinchroniese beginsels in die leksikografie, die onstabiliteit van woordbetekenis, die noodsaak van 'n volledige woordeskatdekking, beginsels van die skryf van definisies, die rol van woordeboeke in die maatskappy, en die noodsaak vir woordeboeke om leiding te gee oor sake van betwiste woordgebruik. Dit sluit af met 'n aantal vrae oor die toekoms van die publikasie van woordeboeke.

    Sleutelwoorde: EENTALIGE WOORDEBOEKE, LEKSIKALE DATABASIS, WOORDEBOEKSTRUKTUUR, WOORDBETEKENIS, BETEKENISVERANDERING, GEBRUIK, GEBRUIKSAANTEKENINGE, HISTORIESE BEGINSELS VAN DIE LEKSIKOGRAFIE, SINCHRONIESE BEGINSELS VAN DIE LEKSIKOGRAFIE, REGISTER, SLANG, STANDAARDENGELS, WOORDESKATDEKKING, KONSEKWENSIE VAN VERSAMELINGS, FRASEOLOGIE, SINTAGMATIESE PATRONE, PROBLEME VAN KOMPOSISIONALITEIT, LINGUISTIESE PRESKRIPTIVISME, LEKSIKALE GETUIENIS

  11. Sharing analysis in the Pawns compiler

    Directory of Open Access Journals (Sweden)

    Lee Naish

    2015-09-01

    Full Text Available Pawns is a programming language under development that supports algebraic data types, polymorphism, higher order functions and “pure” declarative programming. It also supports impure imperative features including destructive update of shared data structures via pointers, allowing significantly increased efficiency for some operations. A novelty of Pawns is that all impure “effects” must be made obvious in the source code and they can be safely encapsulated in pure functions in a way that is checked by the compiler. Execution of a pure function can perform destructive updates on data structures that are local to or eventually returned from the function without risking modification of the data structures passed to the function. This paper describes the sharing analysis which allows impurity to be encapsulated. Aspects of the analysis are similar to other published work, but in addition it handles explicit pointers and destructive update, higher order functions including closures and pre- and post-conditions concerning sharing for functions.

  12. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive......: A total of 173 patients were diagnosed with SVD by echocardiography. Of these, 64 (11%) patients had severe SVD and 109 (19%) patients moderate SVD. Severe SVD was associated with the age of the prosthesis and small prosthesis size [Size 21: hazard ratio (95% confidence interval, CI) 2.72 (0.97-8.56), P...

  13. Reasons for conversion and adverse intraoperative events in Endoscopic Port Access™ atrioventricular valve surgery and minimally invasive aortic valve surgery.

    Science.gov (United States)

    van der Merwe, Johan; Van Praet, Frank; Stockman, Bernard; Degrieck, Ivan; Vermeulen, Yvette; Casselman, Filip

    2018-02-14

    This study reports the factors that contribute to sternotomy conversions (SCs) and adverse intraoperative events in minimally invasive aortic valve surgery (MI-AVS) and minimally invasive Endoscopic Port Access™ atrioventricular valve surgery (MI-PAS). In total, 3780 consecutive patients with either aortic valve disease or atrioventricular valve disease underwent minimally invasive valve surgery (MIVS) at our institution between 1 February 1997 and 31 March 2016. MI-AVS was performed in 908 patients (mean age 69.2 ± 11.3 years, 45.2% women, 6.2% redo cardiac surgery) and MI-PAS in 2872 patients (mean age 64.1 ± 13.3 years, 46.7% women, 12.2% redo cardiac surgery). A cumulative total of 4415 MIVS procedures (MI-AVS = 908, MI-PAS = 3507) included 1537 valve replacements (MI-AVS = 896, MI-PAS = 641) and 2878 isolated or combined valve repairs (MI-AVS = 12, MI-PAS = 2866). SC was required in 3.0% (n = 114 of 3780) of MIVS patients, which occurred in 3.1% (n = 28 of 908) of MI-AVS patients and 3.0% (n = 86 of 2872) of MI-PAS patients, respectively. Reasons for SC in MI-AVS included inadequate visualization (n = 4, 0.4%) and arterial cannulation difficulty (n = 7, 0.8%). For MI-PAS, SC was required in 54 (2.5%) isolated mitral valve procedures (n = 2183). Factors that contributed to SC in MI-PAS included lung adhesions (n = 35, 1.2%), inadequate visualization (n = 2, 0.1%), ventricular bleeding (n = 3, 0.1%) and atrioventricular dehiscence (n = 5, 0.2%). Neurological deficit occurred in 1 (0.1%) and 3 (3.5%) MI-AVS and MI-PAS conversions, respectively. No operative or 30-day mortalities were observed in MI-AVS conversions (n = 28). The 30-day mortality associated with SC in MI-PAS (n = 86) was 10.5% (n = 9). MIVS is increasingly being recognized as the 'gold-standard' for surgical valve interventions in the context of rapidly expanding catheter-based technology and increasing

  14. Valve Repair or Replacement

    Science.gov (United States)

    ... Rounds Seminar Series & Daily Conferences Fellowships and Residencies School of Perfusion Technology Education Resources Library & Learning Resource Center CME Resources THI Journal THI Cardiac Society Register for the Cardiac Society ...

  15. Mitral Valve Prolapse

    Science.gov (United States)

    ... Rounds Seminar Series & Daily Conferences Fellowships and Residencies School of Perfusion Technology Education Resources Library & Learning Resource Center CME Resources THI Journal THI Cardiac Society Register for the Cardiac Society ...

  16. Bicuspid Aortic Valve Disease: A Comprehensive Review

    OpenAIRE

    Mordi, Ify; Tzemos, Nikolaos

    2012-01-01

    Bicuspid aortic valve is the commonest congenital cardiac abnormality in the general population. This paper article will discuss our current knowledge of the anatomy, pathophysiology, genetics, and clinical aspects of bicuspid aortic valve disease.

  17. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  18. Bistable fluidic valve is electrically switched

    Science.gov (United States)

    Fiet, O.; Salvinski, R. J.

    1970-01-01

    Bistable control valve is selectively switched by direct application of an electrical field to divert fluid from one output channel to another. Valve is inexpensive, has no moving parts, and operates on fluids which are relatively poor electrical conductors.

  19. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  20. Prosthetic Mitral Valve Leaflet Escape

    Science.gov (United States)

    Kim, Darae; Hun, Sin Sang; Cho, In-Jeong; Shim, Chi-Young; Ha, Jong-Won; Chung, Namsik; Ju, Hyun Chul; Sohn, Jang Won

    2013-01-01

    Leaflet escape of prosthetic valve is rare but potentially life threatening. It is essential to make timely diagnosis in order to avoid mortality. Transesophageal echocardiography and cinefluoroscopy is usually diagnostic and the location of the missing leaflet can be identified by computed tomography (CT). Emergent surgical correction is mandatory. We report a case of fractured escape of Edward-Duromedics mitral valve 27 years after the surgery. The patient presented with symptoms of acute decompensated heart failure and cardiogenic shock. She was instantly intubated and mechanically ventilated. After prompt evaluation including transthoracic echocardiography and CT, the escape of the leaflet was confirmed. The patient underwent emergent surgery for replacement of the damaged prosthetic valves immediately. Eleven days after the surgery, the dislodged leaflet in iliac artery was removed safely and the patient recovered well. PMID:23837121

  1. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  2. Statins for aortic valve stenosis

    Directory of Open Access Journals (Sweden)

    Luciana Thiago

    Full Text Available ABSTRACT BACKGROUND: Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. OBJECTIVES: To evaluate the effectiveness and safety of statins in aortic valve stenosis. METHODS: Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL, MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions. Selection criteria: Randomized controlled clinical trials (RCTs comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity, freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life. Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. MAIN RESULTS: We included four RCTs with 2360 participants comparing statins (1185 participants with placebo (1175 participants. We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD -0.54, 95% confidence interval (CI -1.88 to 0.80; participants = 1935; studies = 2, valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2

  3. Statins for aortic valve stenosis.

    Science.gov (United States)

    Thiago, Luciana; Tsuji, Selma Rumiko; Nyong, Jonathan; Puga, Maria Eduarda Dos Santos; Góis, Aécio Flávio Teixeira de; Macedo, Cristiane Rufino; Valente, Orsine; Atallah, Álvaro Nagib

    2016-01-01

    Aortic valve stenosis is the most common type of valvular heart disease in the USA and Europe. Aortic valve stenosis is considered similar to atherosclerotic disease. Some studies have evaluated statins for aortic valve stenosis. To evaluate the effectiveness and safety of statins in aortic valve stenosis. Search methods: We searched the Cochrane Central Register of Controlled Trials (CENTRAL), MEDLINE, Embase, LILACS - IBECS, Web of Science and CINAHL Plus. These databases were searched from their inception to 24 November 2015. We also searched trials in registers for ongoing trials. We used no language restrictions.Selection criteria: Randomized controlled clinical trials (RCTs) comparing statins alone or in association with other systemic drugs to reduce cholesterol levels versus placebo or usual care. Data collection and analysis: Primary outcomes were severity of aortic valve stenosis (evaluated by echocardiographic criteria: mean pressure gradient, valve area and aortic jet velocity), freedom from valve replacement and death from cardiovascular cause. Secondary outcomes were hospitalization for any reason, overall mortality, adverse events and patient quality of life.Two review authors independently selected trials for inclusion, extracted data and assessed the risk of bias. The GRADE methodology was employed to assess the quality of result findings and the GRADE profiler (GRADEPRO) was used to import data from Review Manager 5.3 to create a 'Summary of findings' table. We included four RCTs with 2360 participants comparing statins (1185 participants) with placebo (1175 participants). We found low-quality evidence for our primary outcome of severity of aortic valve stenosis, evaluated by mean pressure gradient (mean difference (MD) -0.54, 95% confidence interval (CI) -1.88 to 0.80; participants = 1935; studies = 2), valve area (MD -0.07, 95% CI -0.28 to 0.14; participants = 127; studies = 2), and aortic jet velocity (MD -0.06, 95% CI -0.26 to 0

  4. Evaluation of mispositioned ECCS valves

    International Nuclear Information System (INIS)

    Hill, R.A.; O'Brien, J.F.; McIntire, D.C.; Barlow, R.T.

    1977-09-01

    In October of 1975, Westinghouse submitted NS-CE-787, dated October 17, 1975, to the Nuclear Regulatory Commission (NRC) and entered into discussions with them concerning the spurious movement of certain motor-operated valves (MOV's) in the Emergency Core Cooling System (ECCS) to a position defeating the ECCS function at a time when this function is required. On November 25, 1975, the discussion turned to the possible movement of a manually controlled, motor-operated valve due to a fault in its electrical circuitry and the NRC staff expressed concerns about other possible failure modes that might lead to such a valve movement. The NRC meeting minutes document these concerns. This report is an item-by-item response to the concerns expressed by the NRC staff at that meeting and incorporates the original electrical fault analysis

  5. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  6. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  7. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  8. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  9. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  10. HAL/S-360 compiler test activity report

    Science.gov (United States)

    Helmers, C. T.

    1974-01-01

    The levels of testing employed in verifying the HAL/S-360 compiler were as follows: (1) typical applications program case testing; (2) functional testing of the compiler system and its generated code; and (3) machine oriented testing of compiler implementation on operational computers. Details of the initial test plan and subsequent adaptation are reported, along with complete test results for each phase which examined the production of object codes for every possible source statement.

  11. Regulatory and technical reports: compilation for 1975-1978

    International Nuclear Information System (INIS)

    1982-04-01

    This brief compilation lists formal reports issued by the US Nuclear Regulatory Commission in 1975 through 1978 that were not listed in the Regulatory and Technical Reports Compilation for 1975 to 1978, NUREG-0304, Vol. 3. This compilation is divided into two sections. The first consists of a sequential listing of all reports in report-number order. The second section consists of an index developed from keywords in report titles and abstracts

  12. HOPE: Just-in-time Python compiler for astrophysical computations

    Science.gov (United States)

    Akeret, Joel; Gamper, Lukas; Amara, Adam; Refregier, Alexandre

    2014-11-01

    HOPE is a specialized Python just-in-time (JIT) compiler designed for numerical astrophysical applications. HOPE focuses on a subset of the language and is able to translate Python code into C++ while performing numerical optimization on mathematical expressions at runtime. To enable the JIT compilation, the user only needs to add a decorator to the function definition. By using HOPE, the user benefits from being able to write common numerical code in Python while getting the performance of compiled implementation.

  13. Compilations and evaluations of nuclear structure and decay data

    International Nuclear Information System (INIS)

    Lorenz, A.

    1978-10-01

    This is the fourth issue of a report series on published and to-be-published compilations and evaluations of nuclear structure and decay (NSD) data. This compilation is published and distributed by the IAEA Nuclear Data Section every year. The material contained in this compilation is sorted according to eight subject categories: General compilations; basic isotopic properties; nuclear structure properties; nuclear decay processes, half-lives, energies and spectra; nuclear decay processes, gamma-rays; nuclear decay processes, fission products; nuclear decay processes (others); atomic processes

  14. Automatic Parallelization An Overview of Fundamental Compiler Techniques

    CERN Document Server

    Midkiff, Samuel P

    2012-01-01

    Compiling for parallelism is a longstanding topic of compiler research. This book describes the fundamental principles of compiling "regular" numerical programs for parallelism. We begin with an explanation of analyses that allow a compiler to understand the interaction of data reads and writes in different statements and loop iterations during program execution. These analyses include dependence analysis, use-def analysis and pointer analysis. Next, we describe how the results of these analyses are used to enable transformations that make loops more amenable to parallelization, and

  15. Promising results after percutaneous mitral valve repair

    DEFF Research Database (Denmark)

    Ihlemann, Nikolaj; Franzen, Olaf; Jørgensen, Erik

    2011-01-01

    Mitral valve regurgitation (MR) is the secondmost frequent valve disease in Europe. Untreated MR causes considerable morbidity and mortality. In the elderly, as many as half of these patients are denied surgery because of an estimated high surgical risk. Percutaneous mitral valve repair with the ...... with the MitraClip system resembles the Alfieristitch where a clip is used to connect the tip of the mitral valve leaflets....

  16. Infective endocarditis following percutaneous pulmonary valve replacement

    DEFF Research Database (Denmark)

    Cheung, Gary; Vejlstrup, Niels; Ihlemann, Nikolaj

    2013-01-01

    Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult.......Infective endocarditis (IE) following percutaneous pulmonary valve replacement (PPVR) with the Melody valve is rarely reported. Furthermore, there are challenges in this diagnosis; especially echocardiographic evidence of vegetation within the prosthesis may be difficult....

  17. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  18. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  19. Compilation of data for radionuclide transport analysis

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-11-01

    This report is one of the supporting documents to the updated safety assessment (project SAFE) of the Swedish repository for low and intermediate level waste, SFR 1. A number of calculation cases for quantitative analysis of radionuclide release and dose to man are defined based on the expected evolution of the repository, geosphere and biosphere in the Base Scenario and other scenarios selected. The data required by the selected near field, geosphere and biosphere models are given and the values selected for the calculations are compiled in tables. The main sources for the selected values of the migration parameters in the repository and geosphere models are the safety assessment of a deep repository for spent fuel, SR 97, and the preliminary safety assessment of a repository for long-lived, low- and intermediate level waste, SFL 3-5. For the biosphere models, both site-specific data and generic values of the parameters are selected. The applicability of the selected parameter values is discussed and the uncertainty is qualitatively addressed for data to the repository and geosphere migration models. Parameter values selected for these models are in general pessimistic in order not to underestimate the radionuclide release rates. It is judged that this approach combined with the selected calculation cases will illustrate the effects of uncertainties in processes and events that affects the evolution of the system as well as in quantitative data that describes this. The biosphere model allows for probabilistic calculations and the uncertainty in input data are quantified by giving minimum, maximum and mean values as well as the type of probability distribution function.

  20. Compilation of data for radionuclide transport analysis

    International Nuclear Information System (INIS)

    2001-11-01

    This report is one of the supporting documents to the updated safety assessment (project SAFE) of the Swedish repository for low and intermediate level waste, SFR 1. A number of calculation cases for quantitative analysis of radionuclide release and dose to man are defined based on the expected evolution of the repository, geosphere and biosphere in the Base Scenario and other scenarios selected. The data required by the selected near field, geosphere and biosphere models are given and the values selected for the calculations are compiled in tables. The main sources for the selected values of the migration parameters in the repository and geosphere models are the safety assessment of a deep repository for spent fuel, SR 97, and the preliminary safety assessment of a repository for long-lived, low- and intermediate level waste, SFL 3-5. For the biosphere models, both site-specific data and generic values of the parameters are selected. The applicability of the selected parameter values is discussed and the uncertainty is qualitatively addressed for data to the repository and geosphere migration models. Parameter values selected for these models are in general pessimistic in order not to underestimate the radionuclide release rates. It is judged that this approach combined with the selected calculation cases will illustrate the effects of uncertainties in processes and events that affects the evolution of the system as well as in quantitative data that describes this. The biosphere model allows for probabilistic calculations and the uncertainty in input data are quantified by giving minimum, maximum and mean values as well as the type of probability distribution function

  1. 49 CFR 195.260 - Valves: Location.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Valves: Location. 195.260 Section 195.260... PIPELINE Construction § 195.260 Valves: Location. A valve must be installed at each of the following locations: (a) On the suction end and the discharge end of a pump station in a manner that permits isolation...

  2. Porcine Tricuspid Valve Anatomy and Human Compatibility

    DEFF Research Database (Denmark)

    Waziri, Farhad; Lyager Nielsen, Sten; Hasenkam, J. Michael

    2016-01-01

    before clinical use. The study aim was to evaluate and compare the tricuspid valve anatomy of porcine and human hearts. METHODS: The anatomy of the tricuspid valve and the surrounding structures that affect the valve during a cardiac cycle were examined in detail in 100 fresh and 19 formalin...

  3. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  4. Solving the problem of valve stem leakage

    International Nuclear Information System (INIS)

    Dixon, D.F.

    1976-01-01

    Engineering solutions to valve stem leakage, in systems carrying expensive heavy water under pressure, have progressed from changing packing brands (failure) to leak collection (partial success) to elimination of small packed valves and an improved valve packing strategy involving stable packing materials, live Belleville spring-loading of packing, and issuance of a detailed stuffing box specification (success). (E.C.B.)

  5. 49 CFR 229.109 - Safety valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Safety valves. 229.109 Section 229.109..., DEPARTMENT OF TRANSPORTATION RAILROAD LOCOMOTIVE SAFETY STANDARDS Safety Requirements Steam Generators § 229.109 Safety valves. Every steam generator shall be equipped with at least two safety valves that have a...

  6. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  7. Valve Corporation: Strategy Tipping Points and Thresholds

    OpenAIRE

    Teppo Felin

    2015-01-01

    Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012).  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  8. Valve Corporation: Strategy Tipping Points and Thresholds

    Directory of Open Access Journals (Sweden)

    Teppo Felin

    2015-06-01

    Full Text Available Valve Corporation represents an intriguing case study of flat structure and self organization (Puranam & Håkonsson, 2015; Valve, 2012.  The structures and practices of Valve of course are not new. But the company provides an interesting experiment and illustration that powerfully highlights how organizational design can impact individual and collective behavior, strategy and performance.

  9. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  10. Sequential transcatheter aortic valve implantation due to valve dislodgement

    DEFF Research Database (Denmark)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel

    2017-01-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected...

  11. Technology in cardiology

    African Journals Online (AJOL)

    Repro

    technology for the patient who is consult- ing a cardiologist. ... patients with, for example, aortic and mitral valve ... availability in the doctor's rooms. ..... tance, usually via the Internet with .... tic relationship with re g a rd to investigation and inter-.

  12. Internal combustion engines for alcohol motor fuels: a compilation of background technical information

    Energy Technology Data Exchange (ETDEWEB)

    Blaser, Richard

    1980-11-01

    This compilation, a draft training manual containing technical background information on internal combustion engines and alcohol motor fuel technologies, is presented in 3 parts. The first is a compilation of facts from the state of the art on internal combustion engine fuels and their characteristics and requisites and provides an overview of fuel sources, fuels technology and future projections for availability and alternatives. Part two compiles facts about alcohol chemistry, alcohol identification, production, and use, examines ethanol as spirit and as fuel, and provides an overview of modern evaluation of alcohols as motor fuels and of the characteristics of alcohol fuels. The final section compiles cross references on the handling and combustion of fuels for I.C. engines, presents basic evaluations of events leading to the use of alcohols as motor fuels, reviews current applications of alcohols as motor fuels, describes the formulation of alcohol fuels for engines and engine and fuel handling hardware modifications for using alcohol fuels, and introduces the multifuel engines concept. (LCL)

  13. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  14. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  15. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Condition monitoring of a check valve for nuclear power plants by means of acoustic emission technique

    International Nuclear Information System (INIS)

    Lee, M. R.; Lee, J. H.; Kim, J. T.; Kim, J. S.; Luk, V. K.

    2003-01-01

    This work performed in support of the International Nuclear Energy Research Institute (INERI) program, which was to develop and demonstrate advanced sensor and computational technology for on-line monitoring of the condition of components, structures, and systems in advanced and next-generation nuclear power plants (NPPs). This primary object of this work is to investigate advanced condition monitoring systems based on acoustic emission detection that can provide timely detection of check valve degeneration and service aging so that maintenance/replacement could be preformed prior to loss safety function. The research is focused on the capability of AE technique to provide diagnostic information useful in determining check valve aging and degradation check valve failure and undesirable operating modes. This work also includes the investigation and adaptation of several advanced sensor technologies such as accelerometer and advanced ultrasonic technique. In addition, this work will develop advanced sophisticated signal processing, noise reduction, and pattern recognition techniques and algorithms from check valve degradation.

  17. Global compilation of marine varve records

    Science.gov (United States)

    Schimmelmann, Arndt; Lange, Carina B.; Schieber, Juergen; Francus, Pierre; Ojala, Antti E. K.; Zolitschka, Bernd

    2017-04-01

    Marine varves contain highly resolved records of geochemical and other paleoceanographic and paleoenvironmental proxies with annual to seasonal resolution. We present a global compilation of marine varved sedimentary records throughout the Holocene and Quaternary covering more than 50 sites worldwide. Marine varve deposition and preservation typically depend on environmental and sedimentological conditions, such as a sufficiently high sedimentation rate, severe depletion of dissolved oxygen in bottom water to exclude bioturbation by macrobenthos, and a seasonally varying sedimentary input to yield a recognizable rhythmic varve pattern. Additional oceanographic factors may include the strength and depth range of the Oxygen Minimum Zone (OMZ) and regional anthropogenic eutrophication. Modern to Quaternary marine varves are not only found in those parts of the open ocean that comply with these conditions, but also in fjords, embayments and estuaries with thermohaline density stratification, and nearshore 'marine lakes' with strong hydrologic connections to ocean water. Marine varves have also been postulated in pre-Quaternary rocks. In the case of non-evaporitic laminations in fine-grained ancient marine rocks, such as banded iron formations and black shales, laminations may not be varves but instead may have multiple alternative origins such as event beds or formation via bottom currents that transported and sorted silt-sized particles, clay floccules, and organic-mineral aggregates in the form of migrating bedload ripples. Modern marine ecosystems on continental shelves and slopes, in coastal zones and in estuaries are susceptible to stress by anthropogenic pressures, for example in the form of eutrophication, enhanced OMZs, and expanding ranges of oxygen-depletion in bottom waters. Sensitive laminated sites may play the important role of a 'canary in the coal mine' where monitoring the character and geographical extent of laminations/varves serves as a diagnostic

  18. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  19. Spring valve for well completion

    Energy Technology Data Exchange (ETDEWEB)

    Gorbatov, P T

    1966-07-22

    A spring-loaded valve for well completion consists of a housing with a spring-loaded closing element. In order to protect the closing element from corrosion which might lower the pressure drop, the closing element is made in the form of a piston. It is tightly connected with sealing elements. The housing has orifices, overlapping the piston in the initial position.

  20. Hydraulic servo control spool valve

    Science.gov (United States)

    Miller, Donald M.

    1983-01-01

    A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.

  1. An Initial Evaluation of the NAG f90 Compiler

    Directory of Open Access Journals (Sweden)

    Michael Metcalf

    1992-01-01

    Full Text Available A few weeks before the formal publication of the ISO Fortran 90 Standard, NAG announced the world's first f90 compiler. We have evaluated the compiler by using it to assess the impact of Fortran 90 on the CERN Program Library.

  2. Compiling the First Monolingual Lusoga Dictionary | Nabirye | Lexikos

    African Journals Online (AJOL)

    Another theory, the theory of modularity, was used to bridge the gap between the theory of meaning and the compilation process. The modular ... This article, then, gives an overall summary of all the steps involved in the compilation of the Eiwanika ly'Olusoga, i.e. the Monolingual Lusoga Dictionary. Keywords: lexicography ...

  3. Compilations and evaluations of nuclear structure and decay date

    International Nuclear Information System (INIS)

    Lorenz, A.

    The material contained in this compilation is sorted according to eight subject categories: 1. General Compilations; 2. Basic Isotopic Properties; 3. Nuclear Structure Properties; 4. Nuclear Decay Processes: Half-lives, Energies and Spectra; 5. Nuclear Decay Processes: Gamma-rays; 6. Nuclear Decay Processes: Fission Products; 7. Nuclear Decay Processes: (Others); 8. Atomic Processes

  4. Production compilation : A simple mechanism to model complex skill acquisition

    NARCIS (Netherlands)

    Taatgen, N.A.; Lee, F.J.

    2003-01-01

    In this article we describe production compilation, a mechanism for modeling skill acquisition. Production compilation has been developed within the ACT-Rational (ACT-R; J. R. Anderson, D. Bothell, M. D. Byrne, & C. Lebiere, 2002) cognitive architecture and consists of combining and specializing

  5. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  6. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  7. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  8. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  9. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  10. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  11. Study on process of laser cladded nuclear valve parts

    International Nuclear Information System (INIS)

    Zhang Chunliang

    2000-01-01

    The microstructure and performances of the Co-base alloy coatings that are formed by laser cladding, plasma spurt welding and arc surfacing on the nuclear valve-sealing surface have been studied and compared. The combination costs of laser cladding, plasma spurt welding and arc, surfacing have been analyzed and compared. The results showed that the laser cladding processing has the advantages of high efficiency, low energy cost, a little machining allowance, high rate of finished products and low combination cost, compared with plasma spurt welding processing and arc surfacing processing. The laser cladding technology can improve the qualities of nuclear valve parts and increase their service life. Therefore, the laser cladding processing is a new technology with developing potential

  12. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  13. Compilation of kinetic data for geochemical calculations

    International Nuclear Information System (INIS)

    Arthur, R.C.; Savage, D.; Sasamoto, Hiroshi; Shibata, Masahiro; Yui, Mikazu

    2000-01-01

    Kinetic data, including rate constants, reaction orders and activation energies, are compiled for 34 hydrolysis reactions involving feldspars, sheet silicates, zeolites, oxides, pyroxenes and amphiboles, and for similar reactions involving calcite and pyrite. The data are compatible with a rate law consistent with surface reaction control and transition-state theory, which is incorporated in the geochemical software package EQ3/6 and GWB. Kinetic data for the reactions noted above are strictly compatible with the transition-state rate law only under far-from-equilibrium conditions. It is possible that the data are conceptually consistent with this rate law under both far-from-equilibrium and near-to-equilibrium conditions, but this should be confirmed whenever possible through analysis of original experimental results. Due to limitations in the availability of kinetic data for mine-water reactions, and in order to simplify evaluations of geochemical models of groundwater evolution, it is convenient to assume local-equilibrium in such models whenever possible. To assess whether this assumption is reasonable, a modeling approach accounting for couple fluid flow and water-rock interaction is described that can be use to estimate spatial and temporal scale of local equilibrium. The approach is demonstrated for conditions involving groundwater flow in fractures at JNC's Kamaishi in-situ tests site, and is also used to estimate the travel time necessary for oxidizing surface waters to migrate to the level of a HLW repository in crystalline rock. The question of whether local equilibrium is a reasonable assumption must be addressed using an appropriate modeling approach. To be appropriate for conditions at the Kamaishi site using the modeling approach noted above, the fracture fill must closely approximate a porous mine, groundwater flow must be purely advective and diffusion of solutes across the fracture-host rock boundary must not occur. Moreover, the mineralogical and

  14. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen....... We report the first case of surgical valve replacement in a patient with a dysfunctional transcatheter-implanted aortic valve prosthesis 4 months after implantation....

  15. Evaluation of Reflexive Valve Logic for a Shipboard Firemain

    Science.gov (United States)

    2000-01-12

    firemain valves can be used to measure flow rate [2-5]. In addition, several device-level communication technologies such as Lon Works, Modbus, Profibus ...19,20]: Continuity dp ,d(pV)_0 dt 8K (1) Where p = fluid density, lbm/ft3 (kg/m3) t = time, s V = fluid velocity, ft/s (m/s) x = location

  16. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  17. AVARIS. An innovative process to repair seal seat surfaces in gate and check valves

    International Nuclear Information System (INIS)

    Herzing, Karl-Heinz; Breitenberger, Ulf; Grieser, Armin

    2011-01-01

    AREVA Valve Repair in situ - AVARIS in short - is an innovative process for valve repair developed by AREVA. Its main benefit is that valves no longer need to be cut out but can be machined in situ, i.e. within the piping system. AVARIS saves the plant operators time and money, as complete exchanges of valves and the ensuing complex measures become dispensable. AVARIS is of high interest in the worldwide maintenance market, as it can be applied in both nuclear and conventional power plants. Moreover, AVARIS retrofits valves in the secondary and primary circuit which even saves complex nuclear transports. AVARIS fulfills the quality requirements of 3. party authorities in national and international markets. Valves repaired with AVARIS correspond to their original condition with regard to the sealing function. The successful first application on 2 gate valves in a German nuclear power plant proves that this repair technology is very reliable and flexible. Follow-up orders for AVARIS will be realized in several nuclear power plants in 2011. (orig.)

  18. Wedge gate valves selecting essentials in pipeline systems designing based on permissible operation parameters

    Science.gov (United States)

    Zakirnichnaya, M. M.; Kulsharipov, I. M.

    2017-10-01

    Wedge gate valves are widely used at the fuel and energy complex enterprises. The pipeline valves manufacturers indicate the safe operation resource according to the current regulatory and technical documentation. In this case, the resource value of the valve body strength calculation results is taken into consideration as the main structural part. However, it was determined that the wedge gate valves fail before the assigned resource due to the occurrence of conditions under which the wedge breaks in the hooks and, accordingly, the sealing integrity is not ensured. In this regard, it became necessary to assess the conditions under which the resource should be assigned not only to the valve body, but also to take into account the wedge durability. For this purpose, wedge resource calculations were made using the example of ZKL2 250-25 and ZKL2 300-25 valves using the ABAQUS software package FE-SAFE module under the technological parameters influence on the basis of their stressstrain state calculation results. Operating conditions, under which the wedge resource value is lower than the one set by the manufacturer, were determined. A technique for limiting the operating parameters for ensuring the wedge durability during the wedge gate valve assigned resource is proposed.

  19. A compilation of energy costs of physical activities.

    Science.gov (United States)

    Vaz, Mario; Karaolis, Nadine; Draper, Alizon; Shetty, Prakash

    2005-10-01

    There were two objectives: first, to review the existing data on energy costs of specified activities in the light of the recommendations made by the Joint Food and Agriculture Organization/World Health Organization/United Nations University (FAO/WHO/UNU) Expert Consultation of 1985. Second, to compile existing data on the energy costs of physical activities for an updated annexure of the current Expert Consultation on Energy and Protein Requirements. Electronic and manual search of the literature (predominantly English) to obtain published data on the energy costs of physical activities. The majority of the data prior to 1955 were obtained using an earlier compilation of Passmore and Durnin. Energy costs were expressed as physical activity ratio (PAR); the energy cost of the activity divided by either the measured or predicted basal metabolic rate (BMR). The compilation provides PARs for an expanded range of activities that include general personal activities, transport, domestic chores, occupational activities, sports and other recreational activities for men and women, separately, where available. The present compilation is largely in agreement with the 1985 compilation, for activities that are common to both compilations. The present compilation has been based on the need to provide data on adults for a wide spectrum of human activity. There are, however, lacunae in the available data for many activities, between genders, across age groups and in various physiological states.

  20. RESEARCH AND PRACTICE OF THE NEWS MAP COMPILATION SERVICE

    Directory of Open Access Journals (Sweden)

    T. Zhao

    2018-04-01

    Full Text Available Based on the needs of the news media on the map, this paper researches on the news map compilation service, conducts demand research on the service of compiling news maps, designs and compiles the public authority base map suitable for media publication, and constructs the news base map material library. It studies the compilation of domestic and international news maps with timeliness and strong pertinence and cross-regional characteristics, constructs the hot news thematic gallery and news map customization services, conducts research on types of news maps, establish closer liaison and cooperation methods with news media, and guides news media to use correct maps. Through the practice of the news map compilation service, this paper lists two cases of news map preparation services used by different media, compares and analyses cases, summarizes the research situation of news map compilation service, and at the same time puts forward outstanding problems and development suggestions in the service of news map compilation service.

  1. Compilation of PRF Canyon Floor Pan Sample Analysis Results

    Energy Technology Data Exchange (ETDEWEB)

    Pool, Karl N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Minette, Michael J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Wahl, Jon H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Greenwood, Lawrence R. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Coffey, Deborah S. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); McNamara, Bruce K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Bryan, Samuel A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Scheele, Randall D. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Delegard, Calvin H. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Sinkov, Sergey I. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Soderquist, Chuck Z. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Fiskum, Sandra K. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Brown, Garrett N. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Clark, Richard A. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-06-30

    On September 28, 2015, debris collected from the PRF (236-Z) canyon floor, Pan J, was observed to exhibit chemical reaction. The material had been transferred from the floor pan to a collection tray inside the canyon the previous Friday. Work in the canyon was stopped to allow Industrial Hygiene to perform monitoring of the material reaction. Canyon floor debris that had been sealed out was sequestered at the facility, a recovery plan was developed, and drum inspections were initiated to verify no additional reactions had occurred. On October 13, in-process drums containing other Pan J material were inspected and showed some indication of chemical reaction, limited to discoloration and degradation of inner plastic bags. All Pan J material was sealed back into the canyon and returned to collection trays. Based on the high airborne levels in the canyon during physical debris removal, ETGS (Encapsulation Technology Glycerin Solution) was used as a fogging/lock-down agent. On October 15, subject matter experts confirmed a reaction had occurred between nitrates (both Plutonium Nitrate and Aluminum Nitrate Nonahydrate (ANN) are present) in the Pan J material and the ETGS fixative used to lower airborne radioactivity levels during debris removal. Management stopped the use of fogging/lock-down agents containing glycerin on bulk materials, declared a Management Concern, and initiated the Potential Inadequacy in the Safety Analysis determination process. Additional drum inspections and laboratory analysis of both reacted and unreacted material are planned. This report compiles the results of many different sample analyses conducted by the Pacific Northwest National Laboratory on samples collected from the Plutonium Reclamation Facility (PRF) floor pans by the CH2MHill’s Plateau Remediation Company (CHPRC). Revision 1 added Appendix G that reports the results of the Gas Generation Rate and methodology. The scope of analyses requested by CHPRC includes the determination of

  2. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  3. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  4. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  5. Writing Compilers and Interpreters A Software Engineering Approach

    CERN Document Server

    Mak, Ronald

    2011-01-01

    Long-awaited revision to a unique guide that covers both compilers and interpreters Revised, updated, and now focusing on Java instead of C++, this long-awaited, latest edition of this popular book teaches programmers and software engineering students how to write compilers and interpreters using Java. You?ll write compilers and interpreters as case studies, generating general assembly code for a Java Virtual Machine that takes advantage of the Java Collections Framework to shorten and simplify the code. In addition, coverage includes Java Collections Framework, UML modeling, object-oriented p

  6. Compiler design handbook optimizations and machine code generation

    CERN Document Server

    Srikant, YN

    2003-01-01

    The widespread use of object-oriented languages and Internet security concerns are just the beginning. Add embedded systems, multiple memory banks, highly pipelined units operating in parallel, and a host of other advances and it becomes clear that current and future computer architectures pose immense challenges to compiler designers-challenges that already exceed the capabilities of traditional compilation techniques. The Compiler Design Handbook: Optimizations and Machine Code Generation is designed to help you meet those challenges. Written by top researchers and designers from around the

  7. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  8. Organic evaporator steam valve failure

    International Nuclear Information System (INIS)

    Jacobs, R.A.

    1992-01-01

    Defense Waste Processing Facility (DWPF) Technical has requested an analysis of the capacity of the Organic Evaporator (OE) condenser (OEC) be performed to determine its capability in the case where the OE steam flow control valve fails open. Calculations of the OE boilup and the OEC heat transfer coefficient indicate the OEC will have more than enough capacity to remove the heat at maximum OE boilup. In fact, the Salt Cell Vent Condenser (SCVC) should also have sufficient capacity to handle the maximum OE boilup. Therefore, it would require simultaneous loss of OEC and/or SCVC condensing capacity for the steam valve failure to cause high benzene in the Process Vessel Vent System (PVVS)

  9. Aerococcus viridans Native Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Wenwan Zhou

    2013-01-01

    Full Text Available Aerococcus viridans is an infrequent human pathogen and few cases of infective endocarditis have been reported. A case involving a 69-year-old man with colon cancer and hemicolectomy 14 years previously, without recurrence, is reported. A diagnosis of native mitral valve endocarditis was established on the basis of clinical presentation, characteristic echocardiographic findings and pathological specimen examination after urgent valve replacement. A viridans endocarditis appears to be particularly virulent, requiring a surgical approach in four of 10 cases reported and death in one of nine. Given the aggressive nature of A viridans endocarditis and the variable time to diagnosis (a few days to seven months, prompt recognition of symptoms and echocardiography, in addition to blood cultures, should be performed when symptoms persist.

  10. Compilation of requests for nuclear data

    International Nuclear Information System (INIS)

    Rose, P.F.; Daly, A.

    1987-01-01

    This request list summarizes the current needs of the US nuclear energy programs and other applied technologies for experimentally measured nuclear data. The request list is ordered by target nucleus (isotope) and then reaction type (quantity). An attempt has been made to describe the quantity in standard notation. An appendix contains a glossary of the symbols used with a short explanatory text. Because of the changing and continuing character of the need for data request information, as well as the probability that current measurements may satisfy a portion of the request, this report is to be regarded as a working document. In fact, it is maintained as a data base by the National Nuclear Data Center. Procedures for submitting data request, priority assignments, and the DOE/NDC Committee membership are included

  11. Bistable diverter valve in microfluidics

    Czech Academy of Sciences Publication Activity Database

    Tesař, Václav; Bandulasena, H.C.H.

    2011-01-01

    Roč. 50, č. 5 (2011), s. 1225-1233 ISSN 0723-4864 R&D Projects: GA ČR GA101/07/1499; GA AV ČR IAA200760705 Institutional research plan: CEZ:AV0Z20760514 Keywords : fluidics * bistable diverter valves * pressure-driven microfluidics Subject RIV: BK - Fluid Dynamics Impact factor: 1.735, year: 2011 http://www.springerlink.com/content/x4907p1908151522/

  12. Control valve friction operational experience at Darlington NGD

    International Nuclear Information System (INIS)

    Speer, B.

    1995-01-01

    Proper installation of valve packing is an important part of ensuring that control valves operate as intended. Darlington NGD has developed a Valve Packing Program. This program combined with valve diagnostics has enabled the station to ensure that the operability of control valves is maintained after repacking. This paper outlines the process that is used for this. (author)

  13. Transcatheter aortic valve prosthesis surgically replaced 4 months after implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Lund, Jens Teglgaard; Engstrøm, Thomas

    2010-01-01

    Transcatheter aortic valve implantation is a new and rapidly evolving treatment option for high-risk surgical patients with degenerative aortic valve stenosis. Long-term results with these new valve prostheses are lacking, and potential valve dysfunction and failure would require valve replacemen...

  14. On/off multi-poppet valve for switching manifold in discrete fluid power force system PTO in wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2014-01-01

    Fluid power systems are the leading technology for power take off systems in ocean wave energy converters. However, fluid power systems often suffer from poor efficiency, especially in part loads. This degrades the PTO system efficiency and therefore lowers the energy production. To overcome......, the choice of pilot valve, structural mechanical issues and modelling and simulation of various valve configurations. Hence, a mechatronic design process is utilised to choose the best valve configuration....

  15. The development of fusion sensor techniques for condition monitoring of a check valve

    International Nuclear Information System (INIS)

    Seong, S.H.; Kim, J.S.; Hur, S.; Kim, J.T.; Park, W.M.; Cha, D.B.

    2004-01-01

    The failures of check valves are one of the most important problems in nuclear power plants because the reverse flows through the failed check valve impact on the healthy hydraulic loop. The present test method of finding out the mechanical failure of a check valve is very risky in the radiated environments during normal operation. In addition, the detection of failures in the overhaul period is very costly and tedious because many check valves are used in the plants and manual disassembly work is required. We have suggested the fusion sensor technology for detecting the failures of check valves through measuring and analyzing the backward leakage flow and mechanical vibration without disassembling the check valve. The fusion sensor means that more than two sensors are used in order to identify and analyze the changes of the frequency response between the failed check valve and healthy check valve. We use the accelerometer and acoustic emission sensor as an alternative to the fusion sensor methodology. We have found that the acoustic emission sensor would be capable of directly detecting a high frequency acoustic wave generated from backward leakage flow itself at a low pressure and temperature. The accelerometer for detecting the mechanical vibration induced from leakage flows would, also, be useful at a high pressure and temperature from the previous studies. The effectiveness of this system is that it is possible for predictive maintenance and information of the problem valve will be captured and it reduces the radiation exposure for the maintenance personnel during power operation as well as the maintenance period. (orig.)

  16. Defining indicators to motorize block valves aiming to reduce potential leakage applied to OSBRA pipeline

    Energy Technology Data Exchange (ETDEWEB)

    Pires, L.F.G. [Pontificia Universidade Catolica do Rio de Janeiro (PUC-Rio), RJ (Brazil); Sousa, A.G.; Castro, N.C.; Spagnolo, R. [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    The discussion about motorizing block valves is a constant point being brought up when it is intended to control or reduce the amount of liquid leaking in the event of a pipe rupture. During the pipeline's project stage the installation of blocking valves along the pipeline must be taken into consideration to meet the operation and maintenance requirements as well as to reduce the potential amounts of volume being leaked. In existing pipelines, the main concern is the definition of which valves are candidates to be motorized. In both situations criteria should be established to define this choice. A math algorithm was developed to define the potential leakage due to gravity along the pipeline profile where the influence of a valve over another is verified, as well as the contribution of the check valves existing in the pipeline. The present work defines a parameter based on the extension protected by the valve and the reduction of the potential leakage. This parameter is then fed to a worksheet where the efficiency indicators are calculated to each valve eligible to be motorized. It also takes into consideration factors relative to the valve location, such as the environmental sensitivity, risk assessment, social diagnosis and device's proximity to contingency resources. Finally, after considering all the above aspects, it's possible to come up with a final classification, recommending specific valves to be prioritized on an eventual process of motorization adequacies. This methodology was applied, experimentally on a pipe segment of TRANSPETRO's Sao Paulo-Brasilia pipeline - OSBRA , where it proved to be an important technological and management tool. (author)

  17. Aortic valve surgery of the 21st century: sutureless AVR versus TAVI.

    Science.gov (United States)

    Costache, Victor S; Moldovan, Horatiu; Arsenescu, Catalina; Costache, Andreea

    2018-04-01

    Surgical aortic valve replacement (sAVR) has been a safe, effective and time-proven technique and is still the standard of care all over the world for aortic valve treatment. The vast majority of centers perform this procedure by doing a median sternotomy with several disadvantages. While many others specialties went minimally invasive decades ago, in cardiovascular field transcatheter valve implantation was the first minimally invasive valvular procedure that gained rapid worldwide acceptance. Transcatheter valve replacement (TAVR) is now marketed as a procedure that should be performed under local anesthesia, by an interventional cardiologist via trans femoral route with no other healthcare professional invited to the patient selection or case planning. An increasing number of surgeons are promoting minimally invasive aortic valve replacement, which is gaining grounds, especially with the help of the new sutureless valve technology. With these two new technologies emerging, legitimate questions arise and need to be answered - which has the longest durability, lower complication rate and lower overall mortality.

  18. Design of a multi-poppet on-off valve for wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    Fluid power systems are the leading technology for the power take off system in ocean wave energy converters. However, fluid power systems often suffer from poor efficiency, especially in part loads. This degrades the PTO system efficiency and therefore lower the energy production. To overcome...... the issues with poor system efficiency a discrete fluid power system is proposed as a main part of the PTO system. For the discrete system to be feasible large fluid power switching valves are needed. The current paper presents a two stage 1000 L/min@5bar multi-poppet on/off valve with a switching time less......, structural mechanical issues and modelling and simulation of various valve configurations. Hence in the design process a wide variety of topics are combined to chose the best valve configuration....

  19. Fusing a Transformation Language with an Open Compiler

    NARCIS (Netherlands)

    Kalleberg, K.T.; Visser, E.

    2007-01-01

    Program transformation systems provide powerful analysis and transformation frameworks as well as concise languages for language processing, but instantiating them for every subject language is an arduous task, most often resulting in halfcompleted frontends. Compilers provide mature frontends with

  20. Digital compilation bedrock geologic map of the Warren quadrangle, Vermont

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital Data from VG95-4A Walsh, GJ, Haydock, S, Prewitt, J, Kraus, J, Lapp, E, O'Loughlin, S, and Stanley, RS, 1995, Digital compilation bedrock geologic map of the...

  1. AICPA allows low-cost options for compiled financial statements.

    Science.gov (United States)

    Reinstein, Alan; Luecke, Randall W

    2002-02-01

    The AICPA Accounting and Review Services Committee's (ARSC) SSARS No. 8, Amendment to Statement on Standards for Accounting and Review Services No. 1, Compilation and Review of Financial Statements, issued in October 2000, allows financial managers to provide plain-paper, compiled financial statements for the exclusive use of management. Such financial statements were disallowed in 1979 when the AICPA issued SSARS No. 1, Compilation and Review of Financial Statements. With the issuance of SSARS No. 8, financial managers can prepare plain-paper, compiled financial statements when third parties are not expected to rely on the financial statements, management acknowledges such restrictions in writing, and management acknowledges its primary responsibility for the adequacy of the financial statements.

  2. Specification and Compilation of Real-Time Stream Processing Applications

    NARCIS (Netherlands)

    Geuns, S.J.

    2015-01-01

    This thesis is concerned with the specification, compilation and corresponding temporal analysis of real-time stream processing applications that are executed on embedded multiprocessor systems. An example of such applications are software defined radio applications. These applications typically

  3. Gravity Data for Southwestern Alaska (1294 records compiled)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The gravity station data (1294 records) were compiled by the Alaska Geological Survey and the U.S. Geological Survey, Menlo Park, California. This data base was...

  4. Borrowing and Dictionary Compilation: The Case of the Indigenous ...

    African Journals Online (AJOL)

    rbr

    Keywords: BORROWING, DICTIONARY COMPILATION, INDIGENOUS LANGUAGES,. LEXICON, MORPHEME, VOCABULARY, DEVELOPING LANGUAGES, LOAN WORDS, TER-. MINOLOGY, ETYMOLOGY, LEXICOGRAPHY. Opsomming: Ontlening en woordeboeksamestelling: Die geval van in- heemse Suid-Afrikaanse ...

  5. Digital compilation bedrock geologic map of the Milton quadrangle, Vermont

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital Data from VG95-8A Dorsey, R, Doolan, B, Agnew, PC, Carter, CM, Rosencrantz, EJ, and Stanley, RS, 1995, Digital compilation bedrock geologic map of the Milton...

  6. Digital compilation bedrock geologic map of the Lincoln quadrangle, Vermont

    Data.gov (United States)

    Vermont Center for Geographic Information — Digital Data from VG95-5A Stanley, R, DelloRusso, V, Haydock, S, Lapp, E, O'Loughlin, S, Prewitt, J,and Tauvers, PR, 1995, Digital compilation bedrock geologic map...

  7. Source list of nuclear data bibliographies, compilations, and evaluations

    International Nuclear Information System (INIS)

    Burrows, T.W.; Holden, N.E.

    1978-10-01

    To aid the user of nuclear data, many specialized bibliographies, compilations, and evaluations have been published. This document is an attempt to bring together a list of such publications with an indication of their availability and cost

  8. Solidify, An LLVM pass to compile LLVM IR into Solidity

    Energy Technology Data Exchange (ETDEWEB)

    2017-07-12

    The software currently compiles LLVM IR into Solidity (Ethereum’s dominant programming language) using LLVM’s pass library. Specifically, his compiler allows us to convert an arbitrary DSL into Solidity. We focus specifically on converting Domain Specific Languages into Solidity due to their ease of use, and provable properties. By creating a toolchain to compile lightweight domain-specific languages into Ethereum's dominant language, Solidity, we allow non-specialists to effectively develop safe and useful smart contracts. For example lawyers from a certain firm can have a proprietary DSL that codifies basic laws safely converted to Solidity to be securely executed on the blockchain. In another example, a simple provenance tracking language can be compiled and securely executed on the blockchain.

  9. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  10. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  11. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  12. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  13. SVM Support in the Vienna Fortran Compilation System

    OpenAIRE

    Brezany, Peter; Gerndt, Michael; Sipkova, Viera

    1994-01-01

    Vienna Fortran, a machine-independent language extension to Fortran which allows the user to write programs for distributed-memory systems using global addresses, provides the forall-loop construct for specifying irregular computations that do not cause inter-iteration dependences. Compilers for distributed-memory systems generate code that is based on runtime analysis techniques and is only efficient if, in addition, aggressive compile-time optimizations are applied. Since these optimization...

  14. Data compilation for particle-impact desorption, 2

    International Nuclear Information System (INIS)

    Oshiyama, Takashi; Nagai, Siro; Ozawa, Kunio; Takeutchi, Fujio.

    1985-07-01

    The particle impact desorption is one of the elementary processes of hydrogen recycling in controlled thermonuclear fusion reactors. We have surveyed the literature concerning the ion impact desorption and photon stimulated desorption published through the end of 1984 and compiled the data on the desorption cross sections and yields with the aid of a computer. This report presents the results of the compilation in graphs and tables as functions of incident energy, surface temperature and surface coverage. (author)

  15. DLVM: A modern compiler infrastructure for deep learning systems

    OpenAIRE

    Wei, Richard; Schwartz, Lane; Adve, Vikram

    2017-01-01

    Deep learning software demands reliability and performance. However, many of the existing deep learning frameworks are software libraries that act as an unsafe DSL in Python and a computation graph interpreter. We present DLVM, a design and implementation of a compiler infrastructure with a linear algebra intermediate representation, algorithmic differentiation by adjoint code generation, domain-specific optimizations and a code generator targeting GPU via LLVM. Designed as a modern compiler ...

  16. Compilation and analysis of Escherichia coli promoter DNA sequences.

    OpenAIRE

    Hawley, D K; McClure, W R

    1983-01-01

    The DNA sequence of 168 promoter regions (-50 to +10) for Escherichia coli RNA polymerase were compiled. The complete listing was divided into two groups depending upon whether or not the promoter had been defined by genetic (promoter mutations) or biochemical (5' end determination) criteria. A consensus promoter sequence based on homologies among 112 well-defined promoters was determined that was in substantial agreement with previous compilations. In addition, we have tabulated 98 promoter ...

  17. Compilation of presentations on leadership through innovation

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    Nine guest speakers addressed the 88. annual Canadian Gas Association meeting in British Columbia. This volume contains a collection of their speaking notes and diapositives for overhead projection. Subjects discussed included (1) innovations and recent evolutions in the gas industry, (2) the growth of the U.S. natural gas industry, (3) environmental and safety concerns such as carbon monoxide emissions, (4) trends and perspectives regarding the International Gas Union, and (5) a presentation on the emergency response during the Hanshin Earthquake (Japan). All speakers emphasized that from an economic standpoint, natural gas was the most efficient of all of the world`s primary energy sources. Technology holds a great deal of promise for even wider acceptance of natural gas as an efficient energy source. As an example, the progress and expansion in the use of natural gas powered vehicles was cited. With regard to regulations, it was suggested that regulations should allow the industry to move quickly to take advantage of new marketing opportunities as they arise. tabs., figs.

  18. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  19. Optimal valve location in long oil pipelines

    OpenAIRE

    Grigoriev, A.; Grigorieva, N.V.

    2007-01-01

    We address the valve location problem, one of the basic problems in design of long oil pipelines. Whenever a pipeline is depressurized, the shutoff valves block the oil flow and seal the damaged part of the pipeline. Thus, the quantity of oil possibly contaminating the area around the pipeline is determined by the volume of the damaged section of the pipeline between two consecutive valves. Then, ecologic damage can be quantified by the amount of leaked oil and the environmental characteristi...

  20. Bistable (latching) solenoid actuated propellant isolation valve

    Science.gov (United States)

    Wichmann, H.; Deboi, H. H.

    1979-01-01

    The design, fabrication, assembly and test of a development configuration bistable (latching) solenoid actuated propellant isolation valve suitable for the control hydrazine and liquid fluorine to an 800 pound thrust rocket engine is described. The valve features a balanced poppet, utilizing metal bellows, a hard poppet/seat interface and a flexure support system for the internal moving components. This support system eliminates sliding surfaces, thereby rendering the valve free of self generated particles.

  1. Improved valve and dash-pot assembly

    Science.gov (United States)

    Chang, S.C.

    1985-04-23

    A dash-pot valve comprises a cylinder submerged in the fluid of a housing and have a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with targentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  2. Valve and dash-pot assembly

    Science.gov (United States)

    Chang, Shih-Chih

    1986-01-01

    A dash-pot valve comprising a cylinder submerged in the fluid of a housing and having a piston attached to a plunger projecting into the path of closing movement of a pivotal valve member. A vortex chamber in said cylinder is provided with tangentially directed inlets to generate vortex flow upon retraction of said plunger and effect increasing resistance against said piston to progressively retard the closing rate of said valve member toward its seat.

  3. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  4. Fast Flux Test Facility primary sodium valves

    International Nuclear Information System (INIS)

    Rabe, G.B.; Ezra, B.C.

    1977-01-01

    The design and development of the valves used in the primary sodium coolant loop of the Fast Flux Test Facility is described. One tilting-disk check valve is used in the cold leg of the coolant loop. It is designed to limit flow reversal in the loop while maintaining a low pressure drop during forward flow. Two isolation valves are used in each coolant loop--one in the cold leg and one in the hot leg. They are of the motor-operated swinging-gate type. The design, analysis, and testing programs undertaken to develop and qualify these valves are described

  5. Advantages of butterfly valves for power plants

    International Nuclear Information System (INIS)

    Lapadat, J.T.

    1977-01-01

    Butterfly valves are increasingly used in nuclear power plants. They are used in CANDU reactors for class 2 and 3 service, to provide emergency and tight shutoff valves for all inlets and outlets of heat exchangers and all calandria penetrations. Guidelines for meeting nuclear power plant valve specifications are set out in ASME Section 3, Nuclear Power Plant Components. Some details of materials of construction, type of actuator, etc., for various classes of nuclear service are tabulated in the present article. The 'fishtail' butterfly valve is an improved design with reduced drag, as is illustrated and explained. (N.D.H.)

  6. Additively Manufactured Main Fuel Valve Housing

    Science.gov (United States)

    Eddleman, David; Richard, Jim

    2015-01-01

    Selective Laser Melting (SLM) was utilized to fabricate a liquid hydrogen valve housing typical of those found in rocket engines and main propulsion systems. The SLM process allowed for a valve geometry that would be difficult, if not impossible to fabricate by traditional means. Several valve bodies were built by different SLM suppliers and assembled with valve internals. The assemblies were then tested with liquid nitrogen and operated as desired. One unit was also burst tested and sectioned for materials analysis. The design, test results, and planned testing are presented herein.

  7. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  8. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  9. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  10. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  11. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  12. Safety valve including a hydraulic brake and hydraulic brake that could be fitted into a valve

    International Nuclear Information System (INIS)

    Chabat-Courrede, Jean.

    1981-01-01

    Making of a safety valve that can be fitted to a containment vessel filled with a non compressible fluid, such as the water system of a nuclear power station. It includes a hydraulic brake located between the valve and the elastic means, close to the valve which completely suppresses the high frequency oscillations of the equipment [fr

  13. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  14. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  15. SEBIM pilot operated valves - CANDU and other applications

    International Nuclear Information System (INIS)

    Schaumburg, Gerald; Hera, Vlad

    1999-01-01

    of the reactor. The valves are in service since 1995 and give full satisfaction to the user. Prior to installation they were not only thoroughly lab tested, as already mentioned, but their functions were modelled with the help of a computer simulation software and subjected to physically impossible conditions of fast transients. No need to say, our equipment passed this challenge with flying colors. The Kozloduy Power Plant purchased SEBIM relief valves for use on the nuclear side as well as on the conventional side. All these items were tested, following not only the requirements of the Bulgarian regulator but also those of the French regulator. The SEBIM pilot operated valves are a superior product, ready to satisfied the most demanding customers around the world. They have been successfully used in CANDU and more than 80 nuclear PWR's. They represent an advanced technology, appropriate for many CANDU applications, where they may prove better than the spring-loaded, presently in use. (authors)

  16. Externally heated valve engine a new approach to piston engines

    CERN Document Server

    Kazimierski, Zbyszko

    2016-01-01

    This book reports on a novel approach for generating mechanical energy from different, external heat sources using the body of a typical piston engine with valves. By presenting simple yet effective numerical models, the authors show how this new approach, which combines existing internal combustion technology with a lubrication system, is able to offer an economic solution to the problem of mechanical energy generation in piston engines. Their results also show that a stable heat generation process can be guaranteed outside of the engine. The book offers a detailed report on physical and numerical models of 4-stroke and 2-stroke versions of the EHVE together with different models of heat exchange, valves and results of their simulations. It also delivers the test results of an engine prototype run in laboratory conditions. By presenting a novel theoretical framework and providing readers with extensive knowledge of both the advantages and challenges of the method, this book is expected to inspire academic re...

  17. Pulmonary valve replacement in patients with corrected tetralogy of Fallot

    Directory of Open Access Journals (Sweden)

    Fotios M. Mitropoulos

    2017-06-01

    Results: There were 2 perioperative deaths (2%. One patient developed sternal dehiscence requiring rewiring. Median ICU and hospital stay was 1 and 7 days respectively. Postoperative echocardiography at 6 and 12 months showed excellent bioprosthetic valve performance, significant decrease in size of the right cardiac chambers and reduction of tricuspid regurgitation (TR in the majority of the patients. At mean follow-up of 3.6 ± 2 years, all surviving patients remain in excellent clinical condition. Conclusion: Probability of reoperation for pulmonary insufficiency in patients with surgically corrected TOF increases with time and timely PVR by preventing the development of right heart failure is crucial for long-term survival. Current bioprosthetic valve technology in combination with the beating heart technique provides excellent immediate and short-term results. Further follow-up is necessary to evaluate long-term outcome.

  18. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  19. A shut-off valve for flexible tubing

    Science.gov (United States)

    Reyburn, W. W.

    1972-01-01

    Design of light weight valve for flexible tubing is described. Valve is hand operated and provides positive sealing in normally closed position. Diagram is provided to show construction of valve. Principles of operation are explained.

  20. Irradiation of bulbs and tuber crops. A compilation of technical data for its authorization and control

    International Nuclear Information System (INIS)

    1997-04-01

    This publication contains a compilation of available scientific and technical data on the irradiation of bulbs and tuber crops. It is intended to assist governments in considering the authorization of this particular application of radiation processing of food and in ensuring its control in the facility and the control of irradiated food products moving in trade. The compilation was prepared in response to the requirement of the Codex General Standard for Irradiated Foods and associated Code that radiation treatment of food be justified on the basis of a technological need or of a need to improve the hygienic quality of the food. It was also in response to the recommendations of the FAO/IAEA/WHO/ITC-UNCTAD/GATT International Conference on the Acceptance, Control of and Trade in Irradiated Food (Geneva, 1989) concerning the need for regulatory control of radiation processing of food. 448 refs, 6 tabs

  1. Irradiation of strawberries. A compilation of technical data for its authorization and control

    International Nuclear Information System (INIS)

    1994-12-01

    The document contains a compilation of all available scientific and technical data on the irradiation of strawberries. It is intended to assist governments in considering the authorization of this particular application of radiation processing of food and in ensuring its control in the facility and the control of irradiated food products moving in trade. The compilation was prepared in response to the requirement of the Codex General Standard for Irradiated Foods and associated Code that radiation treatment of food be justified on the basis of a technological need or of a need to improve the hygienic quality of food. It was prepared also in response to the recommendations of the FAO/IAEA/WHO/ITC-UNCTAD/GATT International conference on the Acceptance, Control of and Trade in Irradiated Food (Geneva, 1989) concerning the need for regulatory control of radiation processing of food. Refs, 1 tab

  2. An Optimizing Compiler for Petascale I/O on Leadership Class Architectures

    Energy Technology Data Exchange (ETDEWEB)

    Choudhary, Alok [Northwestern Univ., Evanston, IL (United States); Kandemir, Mahmut [Pennsylvania State Univ., State College, PA (United States)

    2015-03-18

    In high-performance computing systems, parallel I/O architectures usually have very complex hierarchies with multiple layers that collectively constitute an I/O stack, including high-level I/O libraries such as PnetCDF and HDF5, I/O middleware such as MPI-IO, and parallel file systems such as PVFS and Lustre. Our project explored automated instrumentation and compiler support for I/O intensive applications. Our project made significant progress towards understanding the complex I/O hierarchies of high-performance storage systems (including storage caches, HDDs, and SSDs), and designing and implementing state-of-the-art compiler/runtime system technology that targets I/O intensive HPC applications that target leadership class machine. This final report summarizes the major achievements of the project and also points out promising future directions.

  3. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  4. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  5. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  6. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  7. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  8. Operation of Two-Shaft Gas Turbine in the Range of Open Anti-Surge Valve

    Directory of Open Access Journals (Sweden)

    Dzida Marek

    2017-12-01

    Full Text Available This paper presents experimental tests of full-scale two-shaft gas turbine in the range of open anti-surge valve (ASV. The tests were carried out in a laboratory gas- turbine test stand belonging to Department of Automation and Power Engineering , Faculty of Ocean Engineering and Ship Technology , Gdańsk University of Technology. The tests covered the start-up and low load operation of the turbine set in the range of open anti-surge valve.

  9. Dikkers Valves for nuclear industry

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    Most countries have adopted the ASME Boiler and Pressure Vessel Code Section III, as the basis of their national requirements for licensing nuclear components. This Code gives clear directives for defining design requirements coupled with a controlled manufacturing system. It has always been and still is the policy of Dikkers to manufacture high-quality products. Dikkers manufacture nuclear products in accordance with this Code, Section III; indeed many features exceed these minimum requirements. At the Nuclex Exhibition in Basel, Dikkers Valves BV will exhibit its main products for use in nuclear power plants. (Auth.)

  10. Cylinder valve packing nut studies

    Energy Technology Data Exchange (ETDEWEB)

    Blue, S.C. [Martin Marietta Energy Systems, Inc., Paducah, KY (United States)

    1991-12-31

    The design, manufacture, and use of cylinder valve packing nuts have been studied to improve their resistance to failure from stress corrosion cracking. Stress frozen photoelastic models have been analyzed to measure the stress concentrations at observed points of failure. The load effects induced by assembly torque and thermal expansion of stem packing were observed by strain gaging nuts. The effects of finishing operations and heat treatment were studied by the strain gage hole boring and X-ray methods. Modifications of manufacturing and operation practices are reducing the frequency of stress corrosion failures.

  11. Valve Corporation: Composing Internal Markets

    OpenAIRE

    Todd R. Zenger

    2015-01-01

    Discussions of the Valve Corporation are always enlightening. The skeptic wonders how much is rhetoric and recruiting ploy and how much is real. Is there clear evidence that this organizational design actually works – that it is efficient in this setting? While revenues per employee are quite remarkable, cause and effect are unclear. Is “boss-less-ness” the cause of high sales per employee or simply the result of high sales per employee, fueled from earlier success? The same question could be...

  12. Examples, clarifications, and guidance on preparing requests for relief from pump and valve inservice testing requirements

    International Nuclear Information System (INIS)

    Ransom, C.B.; Hartley, R.S.

    1996-02-01

    In this report, the Idaho National Engineering Laboratory reviewers discuss related to requests for relief from the American Society of Mechanical Engineers code requirements for inservice testing (IST) of safety-related pumps and valves at commercial nuclear power plants. This report compiles information and examples that may be useful to licensees in developing relief requests submitted to US Nuclear Regulatory Commission (NRC) for their consideration and provides insights and recommendations on related IST issues. The report also gives specific guidance on relief requests acceptable and not acceptable to the NRC and advises licensees in the use of this information for application at their facilities

  13. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  14. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  15. CAPS OpenACC Compilers: Performance and Portability

    CERN Multimedia

    CERN. Geneva

    2013-01-01

    The announcement late 2011 of the new OpenACC directive-based programming standard supported by CAPS, CRAY and PGI compilers has open up the door to more scientific applications that can be ported on many-core systems. Following a porting methodology, this talk will first review the principles of programming with OpenACC and then the advanced features available in the CAPS compilers to further optimize OpenACC applications: library integration, tuning directives with auto-tune mechanisms to build applications adaptive to different GPUs. CAPS compilers use hardware vendors' backends such as NVIDIA CUDA and OpenCL making them the only OpenACC compilers supporting various many-core architectures. About the speaker Stéphane Bihan is co-funder and currently Director of Sales and Marketing at CAPS enterprise. He has held several R&D positions in companies such as ARC international plc in London, Canon Research Center France, ACE compiler experts in Amsterdam and the INRIA r...

  16. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  17. Anatomical challenges for transcatheter mitral valve intervention

    DEFF Research Database (Denmark)

    De Backer, Ole; Luk, Ngai H V; Søndergaard, Lars

    2016-01-01

    Following the success of transcatheter aortic and pulmonary valve implantation, there is a large interest in transcatheter mitral valve interventions to treat severe mitral regurgitation (MR). With the exception for the MitraClipTM (Abbott, Abbott Park, IL, USA) edge-to-edge leaflet plication...

  18. Transcatheter Aortic Valve Replacement in Europe

    DEFF Research Database (Denmark)

    Mylotte, Darren; Osnabrugge, Ruben L J; Windecker, Stephan

    2013-01-01

    The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy.......The authors sought to examine the adoption of transcatheter aortic valve replacement (TAVR) in Western Europe and investigate factors that may influence the heterogeneous use of this therapy....

  19. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  20. Nuclear valves and the licencing authority

    International Nuclear Information System (INIS)

    Stevens-Guille, P.D.

    1977-02-01

    Valve problems relevant to licencing authorities are discussed. It is suggested that the probability of valve failure should be given more emphasis in safety analysis. Problems of stress analysis, codes, seismic effects, malfunction and leakage are discussed and programmes aimed at solving future problems are outlined