WorldWideScience

Sample records for valve pressure locking

  1. Pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kelly, E.M.

    1996-12-01

    Pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. Supplement 6 to Generic Letter 89-10, {open_quotes}Safety-Related Motor-Operated Gate Valve Testing and Surveillance,{close_quotes} provided an acceptable approach to addressing pressure locking and thermal binding of gate valves. More recently, the NRC has issued Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} to request that licensees take certain actions to ensure that safety-related power-operated gate valves that are susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases. Over the past two years, several plants in Region I determined that valves in certain systems were potentially susceptible to pressure locking and thermal binding, and have taken various corrective actions. The NRC Region I Systems Engineering Branch has been actively involved in the inspection of licensee actions in response to the pressure locking and thermal binding issue. Region I continues to maintain an active involvement in this area, including participation with the Office of Nuclear Reactor Regulation in reviewing licensee responses to Generic Letter 95-07.

  2. Workshop on gate valve pressure locking and thermal binding

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.J.

    1995-07-01

    The purpose of the Workshop on Gate Valve Pressure Locking and Thermal Binding was to discuss pressure locking and thermal binding issues that could lead to inoperable gate valves in both boiling water and pressurized water reactors. The goal was to foster exchange of information to develop the technical bases to understand the phenomena, identify the components that are susceptible, discuss actual events, discuss the safety significance, and illustrate known corrective actions that can prevent or limit the occurrence of pressure locking or thermal binding. The presentations were structured to cover U.S. Nuclear Regulatory Commission staff evaluation of operating experience and planned regulatory activity; industry discussions of specific events, including foreign experience, and efforts to determine causes and alleviate the affects; and valve vendor experience and recommended corrective action. The discussions indicated that identifying valves susceptible to pressure locking and thermal binding was a complex process involving knowledge of components, systems, and plant operations. The corrective action options are varied and straightforward.

  3. A method for evaluating pressure locking and thermal binding of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Dogan, T.

    1996-12-01

    A method is described to evaluate the susceptibility of gate valves to pressure locking and thermal binding. Binding of the valve disc in the closed position due to high pressure water trapped in the bonnet cavity (pressure locking) or differential thermal expansion of the disk in the seat (thermal binding) represents a potential mechanism that can prevent safety-related systems from functioning when called upon. The method described here provides a general equation that can be applied to a given gate valve design and set of operating conditions to determine the susceptibility of the valve to fail due to disc binding. The paper is organized into three parts. The first part discusses the physical mechanisms that cause disc binding. The second part describes the mathematical equations. The third part discusses the conclusions.

  4. Pressure locking test results

    Energy Technology Data Exchange (ETDEWEB)

    DeWall, K.G.; Watkins, J.C.; McKellar, M.G.; Bramwell, D. [Idaho National Engineering Lab., Idaho Falls, ID (United States)] [and others

    1996-12-01

    The U.S. Nuclear Regulatory Commission (NRC), Office of Nuclear Regulatory Research, is funding the Idaho National Engineering Laboratory (INEL) in performing research to provide technical input for their use in evaluating responses to Generic Letter 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves.{close_quotes} Pressure locking and thermal binding are phenomena that make a closed gate valve difficult to open. This paper discusses only the pressure locking phenomenon in a flexible-wedge gate valve; the authors will publish the results of their thermal binding research at a later date. Pressure locking can occur when operating sequences or temperature changes cause the pressure of the fluid in the bonnet (and, in most valves, between the discs) to be higher than the pressure on the upstream and downstream sides of the disc assembly. This high fluid pressure presses the discs against both seats, making the disc assembly harder to unseat than anticipated by the typical design calculations, which generally consider friction at only one of the two disc/seat interfaces. The high pressure of the bonnet fluid also changes the pressure distribution around the disc in a way that can further contribute to the unseating load. If the combined loads associated with pressure locking are very high, the actuator might not have the capacity to open the valve. The results of the NRC/INEL research discussed in this paper show that the relationship between bonnet pressure and pressure locking stem loads appears linear. The results also show that for this valve, seat leakage affects the bonnet pressurization rate when the valve is subjected to thermally induced pressure locking conditions.

  5. Management of a locked Strata valve.

    Science.gov (United States)

    Bullivant, Kelly J; Mitha, Alim P; Hamilton, Mark G

    2009-04-01

    The PS Medical Strata valve is a programmable shunt valve used in the treatment of hydrocephalus that allows for noninvasive changes in the pressure setting using a magnet. The Strata valve is sensitive to magnetic fields, and reprogramming is frequently necessary after MR imaging. A known but rare complication of the Strata valve is that the rotor can become locked, causing shunt malfunction. This complication can only occur in a first generation Strata valve.

  6. Commonwealth Edison Company pressure locking test report

    Energy Technology Data Exchange (ETDEWEB)

    Bunte, B.D.; Kelly, J.F.

    1996-12-01

    Pressure Locking is a phenomena which can cause the unseating thrust for a gate valve to increase dramatically from its typical static unseating thrust. This can result in the valve actuator having insufficient capability to open the valve. In addition, this can result in valve damage in cases where the actuator capability exceeds the valve structural limits. For these reasons, a proper understanding of the conditions which may cause pressure locking and thermal binding, as well as a methodology for predicting the unseating thrust for a pressure locked or thermally bound valve, are necessary. This report discusses the primary mechanisms which cause pressure locking. These include sudden depressurization of piping adjacent to the valve and pressurization of fluid trapped in the valve bonnet due to heat transfer. This report provides a methodology for calculating the unseating thrust for a valve which is pressure locked. This report provides test data which demonstrates the accuracy of the calculation methodology.

  7. The braking performance of a vehicle anti-lock brake system featuring an electro-rheological valve pressure modulator

    Science.gov (United States)

    Choi, Seung-Bok; Sung, Kum-Gil; Cho, Myung-Soo; Lee, Yang-Sub

    2007-08-01

    This paper presents the braking performances of a vehicle anti-lock brake system (ABS) featuring an electro-rheological (ER) valve pressure modulator. As a first step, the principal design parameters of the ER valve and hydraulic booster are appropriately determined by considering the Bingham property of the ER fluid and the braking pressure variation during the ABS operation. An ER fluid composed of chemically treated starch particles and silicone oil is used. An electrically controllable pressure modulator is then constructed and its pressure controllability is empirically evaluated. Subsequently, a quarter-car wheel slip model is established and integrated with the governing equation of the pressure modulator. A sliding mode controller for slip rate control is designed and implemented via the hardware-in-the-loop simulation (HILS). In order to demonstrate the superior braking performance of the proposed ABS, a full car model is derived and a sliding mode controller is formulated to achieve the desired yaw rate. The braking performances in terms of braking distance and step input steering are evaluated and presented in time domain through full car simulations.

  8. Field Experience with Lock Culvert Valves

    Science.gov (United States)

    2013-12-01

    interesting accounts regarding their lock culvert valves. ST. LAWRENCE SEAWAY Eisenhower and Snell Locks. The valves on the Eisenhower and Snell Locks...Tainter Valve Design Lift, ft Eisenhower St. Lawrence Seaway 80 x 860 12 x 14 21.0 DSP 43 Snell St. Lawrence Seaway 80 x 860 12 x 14 21.0 3 DSP, 1 VF 49...vertical-frame valves were furnished to the SLSDC in January 2011, and one was installed in the south filling-valve location at Snell Lock. An option

  9. Wheel slip control of ABS using ER valve pressure modulator

    Science.gov (United States)

    Choi, Seung-Bok; Cho, Myung-Soo; Kim, Yong-Il; Choi, Young-Tai; Wereley, Norman M.

    2004-07-01

    This paper presents a wheel slip control via sliding mode controller for a new anti-lock brake system (ABS) of a passenger vehicle using electrorheological (ER) valve pressure modulator. The principal design parameters of the ER valves and hydraulic booster are appropriately determined by considering braking pressure variation during ABS operation. An electrically controllable pressure modulator using the ER valves is then constructed and its governing equations are derived. Subsequently, the pressure control performance of the new pressure modulator is experimentally evaluated. The governing equations of motion for a quarter car wheel model are derived and the sliding mode controller is formulated for wheel slip control. Hardware in the loop simulation (HILS) for braking performance evaluation is undertaken in order to demonstrate the effectiveness of the proposed ABS associated with the ER valve pressure modulator.

  10. Effects of pressure and temperature on gate valve unwedging

    Energy Technology Data Exchange (ETDEWEB)

    Damerell, P.S.; Harrison, D.H.; Hayes, P.W.; Simons, J.W.; Walker, T.A.

    1996-12-01

    The stem thrust required to unwedge a gate valve is influenced by the pressure and temperature when the valve is closed and by the changes in these conditions between closure and opening. {open_quotes}Pressure locking{close_quotes} and {open_quotes}thermal binding{close_quotes} refer to situations where pressure and temperature effects cause the unwedging load to be much higher than normal. A model of these phenomena has been developed. Wedging (closure) is modeled as developing an {open_quotes}interference{close_quotes} between the disk and its seat rings in the valve. The effects of pressure and temperature are analyzed to determine the change in this disk-to-seat {open_quotes}interference{close_quotes}. Flexibilities, of the disk, body, stem and yoke strongly influence the unwedging thrust. Calculations and limited comparisons to data have been performed for a range of valve designs and scenarios. Pressure changes can increase the unwedging load when there is either a uniform pressure decrease, or a situation where the bonnet pressure exceeds the pressures in the adjacent piping. Temperature changes can increase the unwedging load when: (1) valve closure at elevated system temperature produces a delayed stem expansion, (2) a temperature increase after closure produces a bonnet pressure increase, or (3) a temperature change after closure produces an increase in the disk-to-seat {open_quotes}interference{close_quotes} or disk-to-seat friction.

  11. Control performance of an electrorheological valve based vehicle anti-lock brake system, considering the braking force distribution

    Science.gov (United States)

    Choi, S. B.; Lee, T. H.; Lee, Y. S.; Han, M. S.

    2005-12-01

    This paper presents the braking control performance of a vehicle anti-lock brake system featuring an electrorheological (ER) fluid. As a first step, a cylindrical type of ER valve is devised and its pressure controllability is experimentally confirmed. Then, a hydraulic booster for amplifying the field-dependent pressure drop obtained from the ER valve is constructed and its pressure amplification is demonstrated by presenting the pressure tracking control performance. Subsequently, the governing equation of the rear wheel model is derived by considering the braking force distribution, and a sliding mode controller for achieving the desired slip rate is designed. The controller is then realized through the hardware-in-the-loop simulation method and controlled responses are presented in the time domain. In addition, computer animations for the braking performance under unladen and laden conditions are presented, and a comparison of the proportioning valve and the proposed ER valve pressure modulator is made.

  12. Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway

    Science.gov (United States)

    2015-06-01

    ER D C/ CH L TR -1 5- 7 Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway Co as ta l a nd H...client/default. ERDC/CHL TR-15-7 June 2015 Hydraulic Evaluation of Culvert Valves at Eisenhower and Snell Locks, St. Lawrence Seaway...ERDC/CHL TR-15-7 ii Abstract The aged, double-skin-plate valves of the Eisenhower and Snell Locks on the St. Lawrence Seaway are being replaced

  13. Glovebox pressure relief and check valve

    Energy Technology Data Exchange (ETDEWEB)

    Blaedel, K.L.

    1986-03-17

    This device is a combined pressure relief valve and check valve providing overpressure protection and preventing back flow into an inert atmosphere enclosure. The pressure relief is embodied by a submerged vent line in a mercury reservior, the releif pressure being a function of the submerged depth. The pressure relief can be vented into an exhaust system and the relieving pressure is only slightly influenced by the varying pressure in the exhaust system. The check valve is embodied by a ball which floats on the mercury column and contacts a seat whenever vacuum exists within the glovebox enclosure. Alternatively, the check valve is embodied by a vertical column of mercury, the maximum back pressure being a function of the height of the column of mercury.

  14. Pressure tracking control of vehicle ABS using piezo valve modulator

    Science.gov (United States)

    Jeon, Juncheol; Choi, Seung-Bok

    2011-03-01

    This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.

  15. NRC staff review of licensee responses to pressure-locking and thermal-binding issue

    Energy Technology Data Exchange (ETDEWEB)

    Rathbun, H.J.

    1996-12-01

    Commercial nuclear power plant operating experience has indicated that pressure locking and thermal binding represent potential common mode failure mechanisms that can cause safety-related power-operated gate valves to fail in the closed position, thus rendering redundant safety-related systems incapable of performing their safety functions. In Generic Letter (GL) 95-07, {open_quotes}Pressure Locking and Thermal Binding of Safety-Related Power-Operated Gate Valves,{close_quotes} the U.S. Nuclear Regulatory Commission (NRC) staff requested that nuclear power plant licensees take certain actions to ensure that valves susceptible to pressure locking or thermal binding are capable of performing their safety functions within the current licensing bases of the facility. The NRC staff has received summary information from licensees in response to GL 95-07 describing actions they have taken to prevent the occurrence of pressure locking and thermal binding. The NRC staff has developed a systematic process to help ensure uniform and consistent review of licensee submittals in response to GL 95-07.

  16. Control Performance of Vehicle Abs Featuring ER Valve Pressure Modulator

    Science.gov (United States)

    Cho, M. S.; Choi, S. B.; Wereley, N. M.

    In this work, an electrically controllable anti-lock brake system (ABS) for passenger vehicle is developed by utilizing electrorheological (ER) fluid. A pressure modulator which consists of a cylindrical ER valve and the hydraulic booster is constructed in order to achieve sufficient brake pressure variation during ABS operation. The principal design parameters of the modulator are determined by considering ER properties as well as required braking pressure. After investigating pressure controllability of the modulator, a vehicle model which is integrated with the proposed pressure modulator is formulated to design yaw rate controller. A sliding mode controller is designed to obtain desired yaw rate, and the friction forces between roads and wheels are estimated via the estimator. Braking performances of the proposed ABS under various roads are evaluated through the hardware-in-the-loop-simulation (HILS) and the steering stability during braking operation is demonstrated by undertaking split-μ test.

  17. Differential Pressure Helps Seal Ball Valve

    Science.gov (United States)

    Mangialardi, J. K.

    1985-01-01

    Leakage suppressed despite O-ring wear. New design eliminates leakage in vacuum selector valve on Space Shuttle waste-control subsystem. Applied to improve sealing in laboratory and industrial vacuum systems and other plumbing involving switching among lines with pressure differentials of order of 1 atmosphere (0.1 MPa).

  18. 46 CFR 153.368 - Pressure-vacuum valves.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Pressure-vacuum valves. 153.368 Section 153.368 Shipping... Systems § 153.368 Pressure-vacuum valves. (a) The pressure side of a required pressure-vacuum relief valve must begin to open only at a pressure exceeding 3.5 kPa gauge (approx. 0.5 psig). (b) A pressure-vacuum...

  19. Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference

    Science.gov (United States)

    Bao, Xiaoqi (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor)

    2016-01-01

    A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.

  20. Pressurizer Heater and Safety Valve Test for SPACE code

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Dong Hyuk; Youn, Bum Soo; Jun, Hwang Yong; Kim, Se Yun; Ha, Sang Jun [KEPCO Research Institute, Daejeon (Korea, Republic of)

    2011-05-15

    The Korea nuclear industry has been developing a thermal-hydraulic analysis code for safety analysis of PWR(pressurized water reactor). The new code is named SPACE(Safety and Performance Analysis Code for Nuclear Power Plant). In this paper, the pressurizer heater model and safety valve for SPACE code is tested. The SPACE code input for pressurizer is developed and simulations are performed. Calculations were performed with and without heater and safety valve model and results are compared to confirm effectiveness of heater and safety valve

  1. External laser locking using a pressure-tunable microbubble resonator

    CERN Document Server

    Madugani, Ramgopal; Le, Vu H; Ward, Jonathan M; Chormaic, Síle Nic

    2015-01-01

    The tunability of an optical cavity is an essential requirement for many areas of research especially for the rapidly progressing field of photonics. In particular, low-cost laser tuning methods and miniaturization of the optical components are desirable. By applying aerostatic pressure to the interior surface of a microbubble resonator, optical mode shift rates of around $58$ GHz/MPa are achieved. The micobubble can measure pressure with a limit of detection of $2\\times 10^{-4}$ MPa. Here we use the Pound-Drever-Hall technique, whereby a laser is locked to a whispering gallery mode (WGM) of the microbubble resonator, to show that linear tuning of the WGM and the corresponding locked laser display almost zero hysteresis. The long-term frequency stability of this tuning method for different input pressures is measured. The frequency noise of the WGM, measured over 10 minutes, with a maximum input pressure of 0.5 MPa has a standard deviation of 36 MHz.

  2. Transvalvular pressure gradients for different methods of mitral valve repair: only neochordoplasty achieves native valve gradients.

    Science.gov (United States)

    Jahren, Silje Ekroll; Hurni, Samuel; Heinisch, Paul Philipp; Winkler, Bernhard; Obrist, Dominik; Carrel, Thierry; Weber, Alberto

    2018-02-01

    Many surgical and interventional methods are available to restore patency for patients with degenerative severe mitral valve regurgitation. Leaflet resection and neochordoplasty, which both include ring annuloplasty, are the most frequently performed techniques for the repair of posterior mitral leaflet flail. It is unclear which technique results in the best haemodynamics. In this study, we investigated the effect of different mitral valve reconstruction techniques on mitral valve haemodynamics and diastolic transvalvular pressure gradient in an ex vivo porcine model. Eight porcine mitral valves were tested under pulsatile flow conditions in an in vitro pulsatile flow loop for haemodynamic quantification. Severe acute posterior mitral leaflet flail was created by resecting the posterior marginal chorda. The acute mitral valve regurgitation was corrected using 4 different repair techniques, in each valve, in a strictly successive order: (i) neochordoplasty with polytetrafluoroethylene sutures alone and (ii) with ring annuloplasty, (iii) edge-to-edge repair and (iv) triangular leaflet resection, both with ring annuloplasty. Valve haemodynamics were measured and quantified for all valve configurations (native, rupture and each surgical reconstruction). The results were analysed using a validated statistical linear mixed model, and the P-values were calculated using a 2-sided Wald test. All surgical reconstruction techniques were able to sufficiently correct the acute mitral valve regurgitation. Neochordoplasty without ring annuloplasty was the only reconstruction technique that resulted in haemodynamic properties similar to the native mitral valve (P-values from 0.071 to 0.901). The diastolic transvalvular gradient remained within the physiological range for all reconstructions but was significantly higher than in the native valve for neochordoplasty with ring annuloplasty (P < 0.000), edge-to-edge repair (P < 0.000) and leaflet resection (P < 0

  3. Assessment of slurry pressure letdown valve and slurry block valve technology for direct coal liquefaction demonstration and pioneer commercial plants

    Energy Technology Data Exchange (ETDEWEB)

    Krishnan, R.P.

    1984-10-01

    This report examines the status of the technology of high pressure slurry letdown valves and slurry block valves in coal liquefaction service. All of the demonstration and pioneer commercial direct liquefaction plant designs call for the use of high pressure slurry letdown valves for flow control and slurry block valves for flow isolation. Successful performance and reliability of these valves is a serious concern because of the severity of the process streams and the limited experience and performance data on these valves under such conditions. The objectives of this report are: (1) to examine the existing data base on these valves from the four major direct coal liquefaction pilot plants in the US, (2) to present the recommendations from the pilot plant experience, (3) to examine the specifications for the letdown and block valves in the demonstration/pioneer commercial designs, and (4) to identify the scale-up issues, data gaps, and development and testing needs. 23 references, 20 figures, 7 tables.

  4. Posture-independent piston valve: a novel valve mechanism that actuates based on intracranial pressure alone.

    Science.gov (United States)

    Medow, Joshua E; Luzzio, Christopher C

    2012-01-01

    Shunt valves are intended to maintain physiological intracranial pressure (ICP). A variety of mechanisms have been designed to accomplish this goal but have had limited success. Siphoning, in particular, has been a problem not effectively solved by proposed or manufactured valves. Poor control of ICP results in headache, neurological disturbances, decreased cognition, shunt malfunction, slit ventricles, subdural hematomas, decreased cranial volume, and maldevelopment. The authors of this study describe a prototype valve that was machined and tested ex vivo and that actuates based on ICP alone regardless of the presence of a siphon. Their object was to determine if a novel shunt mechanism that actuates perpendicular to the flow of fluid would eliminate the effect of siphoning in a valve for the treatment of hydrocephalus. A posture-independent piston valve (PIPV) was anchored to a graduated reservoir. Opening pressure was measured by noting the fluid level in the reservoir when the piston moved. Measurements were made using a 90-cm and a 120-cm water-filled siphon tube (1.3-mm standard distal catheter) to simulate an upright posture. A recumbent posture was simulated by the absence of a siphon. Opening pressure of the valve did not change regardless of the presence or absence of a water-filled siphon. The PIPV was triggered only by the pressure head at the inlet and did not actuate in the presence of a siphon, demonstrating proof of principle of the perpendicular actuating mechanism. The PIPV is a purely mechanical device that has practical application in the treatment of hydrocephalus.

  5. Digital valve for high pressure high flow applications

    Science.gov (United States)

    Badescu, Mircea; Sherrit, Stewart; Lewis, Derek; Bao, Xiaoqi; Bar-Cohen, Yoseph; Hall, Jeffery L.

    2016-04-01

    To address the challenges, which are involved with the development of flow control valves that can meet high demand requirements such as high pressure, high flow rate, limited power and limited space, the authors have conceived a novel design configuration. This design consists of a digitalized flow control valve with multipath and multistage pressure reduction structures. Specifically, the valve is configured as a set of parallel flow paths from the inlet to the outlet. A choke valve controls the total flow rate by digitally opening different paths or different combination of the paths. Each path is controlled by a poppet cap valve basically operated in on-off states. The number of flow states is 2N where N is the number of flow paths. To avoid erosion from sand in the fluid and high speed flow, the seal area of the poppet cap valve is located at a distance from the flow inlet away from the high speed flow and the speed is controlled to stay below a predefined erosion safe limit. The path is a multistage structure composed of a set of serial nozzles-expansion chambers that equally distribute the total pressure drop to each stage. The pressure drop of each stage and, therefore, the flow speed at the nozzles and expansion chambers is controlled by the number of stages. The paths have relatively small cross section and could be relatively long for large number of stages and still fit in a strict annular space limit. The paper will present the design configuration, analysis and preliminary test results.

  6. How Heart Valves Evolve to Adapt to an Extreme-Pressure System: Morphologic and Biomechanical Properties of Giraffe Heart Valves.

    Science.gov (United States)

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik; Martin Bibby, Bo; Carl Andelius, Ted; Toft Brøndum, Emil; Wang, Tobias; Michael Hasenkam, J

    2017-01-01

    Heart valves which exist naturally in an extreme-pressure system must have evolved in a way to resist the stresses of high pressure. Giraffes are interesting as they naturally have a blood pressure twice that of humans. Thus, knowledge regarding giraffe heart valves may aid in developing techniques to design improved pressure-resistant biological heart valves. Heart valves from 12 giraffes and 10 calves were explanted and subjected to either biomechanical or morphological examinations. Strips from the heart valves were subjected to cyclic loading tests, followed by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations. The aortic valve was shown to be 70% (95% CI 42-103%) stronger in the giraffe than in its bovine counterpart (p giraffe aortic valve was found to be significantly stiffer than the bovine aortic valve (p giraffes contained significantly more collagen than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher in giraffes than in calves, which would make giraffe valves more resistant to the high-pressure forces. However, collagen also stiffens and thickens the valves. The mitral leaflets showed similar (but mostly insignificant) trends in strength, stiffness, and collagen content.

  7. High pressure check valve for application in a miniature cryogenic sorption cooler

    NARCIS (Netherlands)

    Burger, Johannes Faas; van der Wekken, M.C.; Berenschot, Johan W.; Holland, Herman J.; ter Brake, Hermanus J.M.; Rogalla, Horst; Gardeniers, Johannes G.E.; Elwenspoek, Michael Curt

    1999-01-01

    This paper presents a check valve with integrated filter that can stand gas pressures of more than 100 bar in the closed direction and which has a very low pressure drop at low absolute gas pressures in the forward direction. The check valve is designed as a part of a check valve unit for

  8. System for detecting operating errors in a variable valve timing engine using pressure sensors

    Science.gov (United States)

    Wiles, Matthew A.; Marriot, Craig D

    2013-07-02

    A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

  9. 77 FR 59408 - Finding of Equivalence; Alternate Pressure Relief Valve Settings on Certain Vessels Carrying...

    Science.gov (United States)

    2012-09-27

    ...] Finding of Equivalence; Alternate Pressure Relief Valve Settings on Certain Vessels Carrying Liquefied... announces the availability of CG-ENG Policy Letter 04-12, ``Alternative Pressure Relief Valve Settings on.... The higher stress factors lead to lower maximum allowable relief valve settings (MARVS) than are...

  10. Pneumatic oscillations and current noises in pressure control valves; Gasdruckschwingungen und Stroemungsgeraeusche in Druckbegrenzungsventilen und Rohrleitungen

    Energy Technology Data Exchange (ETDEWEB)

    Surek, D.; Stempin, S. [Hochschule Merseburg (F.H.) (Germany). An-Inst. Fluid- und Pumpentechnik

    2005-12-01

    Pressure control valves or overflow valves are inserted for the limited of permissible printings in compressor and pump plants. While attaining permissible printing, the valves open and blow off the supported air volume flow into the environment or the supported gas into a pressure-less receptacle. As a result, the subsequent plant can be protected the the corresponding devices before inadmissibly high printing or a too high gap. Pressure control valves and overflow valves are normally carried out at the same inside diameter of the printing and/or sucking carbine. As a result, redirections and vertebra fields which can lead to strong current noises occur. In order to be able to lower the current noises in pressure control valves the gassing jerk oscillations, the effective sound pressure oscillations and the sound pressure levels of such valves are examined and measured in the following contribution. (orig.)

  11. Transient pressure signals in mechanical heart valve cavitation.

    Science.gov (United States)

    Wu, Z J; Slonin, J H; Hwang, N H

    1996-01-01

    The purpose of this investigation was to establish a correlation between mechanical heart valve (MHV) cavitation and transient pressure (TP) signals at MHV closure. This correlation may suggest a possible method to detect in vivo MHV cavitation. In a pulsatile mock flow loop, a study was performed to measure TP and observe cavitation bubble inception at MHV closure under simulated physiologic ventricular and aortic pressures at heart rates of 70, 90, 120, and 140 beats/min with corresponding cardiac outputs of 5.0, 6.0, 7.5, and 8.5 L/min, respectively. The experimental study included two bileaflet MHV prostheses: 1) St. Jude Medical 31 mm and 2) Carbomedics 31 mm. High fidelity piezo-electric pressure transducers were used to measure TP immediately before and after the valve leaflet/housing impact. A stroboscopic lighting imaging technique was developed to capture cavitation bubbles on the MHV inflow surfaces at selected time delays ranging from 25 microseconds to 1 ms after the leaflet/housing impact. The TP traces measured 10 mm away from the valve leaflet tip showed a large pressure reduction peak at the leaflet/housing impact, and subsequent high frequency pressure oscillations (HPOs) while the cavitation bubbles were observed. The occurrence of cavitation bubbles and HPO bursts were found to be random on a beat by beat basis. However, the amplitude of the TP reduction, the intensity of the cavitation bubble (size and number), and the intensity of HPO were found to increase with the test heart rate. A correlation between the MHV cavitation bubbles and the HPO burst was positively established. Power spectrum analysis of the TP signals further showed that the frequency of the HPO (cavitation bubble collapse pressures) ranged from 100 to 450 kHz.

  12. Dynamic characteristics research of the pressure reducing valve based on AMESim

    Science.gov (United States)

    Wang, Weihui; Zhang, Peiyi

    2017-05-01

    Through the analysis of the structure and working principle of pressure reducing valve, using AMESim software to model, simulate and analyze its working conditions On the basis of the analysis of the structural parameters of the valve: damping hole diameter D, analog load damping hole diameter D1, spring stiffness K and initial opening S 0f analog load, such as which has the impact of hydraulic pressure reducing valve Finally, the influence of the above parameters on the accuracy of the valve is analyzed, which provides a reference for the design of the valve.

  13. Modeling, Parameters Identification, and Control of High Pressure Fuel Cell Back-Pressure Valve

    Directory of Open Access Journals (Sweden)

    Fengxiang Chen

    2014-01-01

    Full Text Available The reactant pressure is crucial to the efficiency and lifespan of a high pressure PEMFC engine. This paper analyses a regulated back-pressure valve (BPV for the cathode outlet flow in a high pressure PEMFC engine, which can achieve precisely pressure control. The modeling, parameters identification, and nonlinear controller design of a BPV system are considered. The identified parameters are used in designing active disturbance rejection controller (ADRC. Simulations and extensive experiments are conducted with the xPC Target and show that the proposed controller can not only achieve good dynamic and static performance but also have strong robustness against parameters’ disturbance and external disturbance.

  14. The effect of distal radius locking plates on articular contact pressures.

    Science.gov (United States)

    Walker, Matthew H; Kim, Hyunchul; Hsieh, Adam H; O'Toole, Robert V; Eglseder, W Andrew

    2011-08-01

    Fractures of the distal radius are among the most common injuries treated in hand surgery practice, and distal radius locking plates have become an increasingly popular method of fixation. Despite widespread use of this technology, it is unknown whether the subchondral placement of locking screws affects the loading profile of the distal radius. Our study was designed to determine whether subchondral locking screws change the articular contact pressures in the distal radius. Twelve cadaveric forearms underwent a previously described axial loading protocol in a materials testing machine. We used an intra-articular, real-time computerized force sensor to measure peak contact pressure, total pressure, and contact area in the distal radius. Internal validation of sensor placement and reproducibility was conducted. Each specimen was tested before fixation (control), after application of a palmar distal radius locking plate, and after simulation of a metaphyseal fracture. We identified no statistically significant differences in maximum pressure, total pressure, and contact area among control, plated, and plated and fractured specimens. However, the contact footprint-represented by squared differences in force across the sensor-were significantly different between the control group and both plated groups. The technique for measuring contact pressures produces highly repeatable values. Distal radius locking plates with subchondral hardware placement do not seem to significantly change articular contact pressures. Copyright © 2011 American Society for Surgery of the Hand. Published by Elsevier Inc. All rights reserved.

  15. Noninvasive assessment of filling pressure and left atrial pressure overload in severe aortic valve stenosis: relation to ventricular remodeling and clinical outcome after aortic valve replacement

    DEFF Research Database (Denmark)

    Dahl, Jordi S; Videbæk, Lars; Poulsen, Mikael K

    2011-01-01

    One of the hemodynamic consequences of aortic valve stenosis is pressure overload leading to left atrial dilatation. Left atrial size is a known risk factor providing prognostic information in several cardiac conditions. It is not known if this is also the case in patients with aortic valve...

  16. Modeling study of the ABS relay valve

    Science.gov (United States)

    Lei, Ming; Lin, Min; Guo, Bin; Luo, Zai; Xu, Weidong

    2011-05-01

    The ABS (anti-lock braking system) relay valve is the key component of anti-lock braking system in most commercial vehicles such as trucks, tractor-trailers, etc. In this paper, structure of ABS relay valve and its work theory were analyzed. Then a mathematical model of ABS relay valve, which was investigated by dividing into electronic part, magnetic part, pneumatic part and mechanical part, was set up. The displacement of spools and the response of pressure increasing, holding, releasing of ABS relay valve were simulated and analyzed under conditions of control pressure 500 KPa, braking pressure 600 KPa, atmospheric pressure 100 KPa and air temperature 310 K. Thisarticle provides reliable theory for improving the performance and efficiency of anti-lock braking system of vehicles.

  17. A Study of System Pressure Transients Generated by Isolation Valve Open/Closure in Orifice Manifold

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. [KEPCO, Daejeon (Korea, Republic of); Bae, S. W.; Kim, J. I.; Park, S. J. [KHNP, Abu Dhabi (United Arab Emirates)

    2016-05-15

    In this study, we explore the effects of pressure transients on peak and minimal pressures caused by the actuation of isolation valve and control valve reacting to the combined orifice operation of orifice manifold with motor-operated valve installed in the rear of the orifice. We then use the collected data to direct our effort towards cause analysis and propose improvements to efficiency and safety of operation. This formation is used to by domestic and foreign nuclear power plants as a mean to control flow rate, producing required flow rate jointly together by combination of the orifices. No significant impacts on the internals of manifold orifice due to peak pressure has been observed, although chance of cavitation at the outlet of control valve is significant. Considering the peak pressure, as well as minimum pressure occurs in low flow rate conditions, the pressure transient is more so affected by the characteristics (modified equal percentage) of control valve. Isolation valve of the orifice and control valve operate organically, therefore stroke time for valves need to be applied in order for both valves to cooperatively formulate an optimized operation.

  18. Smart Electric Valve Controller Based on All Digital Phase-Locked Loop

    Directory of Open Access Journals (Sweden)

    Li Xiaoling

    2014-02-01

    Full Text Available Electric valve has been applied to various occasions and domains. In some adverse environments where such defects of traditional control system as low efficiency and poor safety have been exposed, optical encoder is adopted to detect the motor’s angular speed and displacement and ADPLL is used for generating control logic, so as to regulate switching frequency and duty ratio of pulse wavelength modulation (PWM, alter the motor’s input voltage and current and achieve the open and close control of Electric valve. The system can automatically regulate the rotating speed and the dragging torque of motor based on the open and close position, rotating speed and torque of the valve to make sure that the motor can achieve the best rotating speed and torque. The results of the test by motor 90ZY24-200 prove that the system has prompt response, high accuracy, little harmonic and ripple range; it can also automatically adapt to the torque alteration to realize the protective function of direct current (DC motor. Electric valve control based on ADPLL can not only realize functions of the whole system, but also enjoys a stable and reliable performance. It can reduce the harmonic and ripple, and help the whole system achieve real-time remote control, data collection and transmission, and display the motor torque in LED, so as to control the valve flow stably and accurately through DC motor.

  19. RESEARCH ON NUMERICAL SIMULATION APLICABLE TO THE PRESSURE RELIEF VALVE ON THE BORE GAS EVACUATION DEVICE

    National Research Council Canada - National Science Library

    Gheorghe Negru

    2016-01-01

      The paper presents the research approach on the numerical simulation applicable to pressure relief valve on the bore gas evacuation device embedded on the high pressure barrels with special destinations...

  20. Analysis of regurgitation, mean systolic pressure drop and energy losses for two artificial aortic valves.

    Science.gov (United States)

    Sakhaeimanesh, A A; Morsi, Y S

    1999-01-01

    The work reported here is related to the hydrodynamic performance of a Jellyfish valve and St Vincent valve in terms of total energy losses, mean systolic pressure drop and regurgitation. The in vitro experimental investigation was conducted at cardiac outputs of 3.5, 4.5 and 6.51 min-1 across the two valves and under pulsatile flow condition. It was found that the closure volume of the St Vincent valve was about 2.5 times higher than that of the Jellyfish valve. The total back flow losses on the other hand were found to be in the range of 36.5 to 107.1 and 85.5 to 192.5 mJ for the Jellyfish valve and St Vincent valve respectively. Moreover, the mean systolic pressure drop of the St Vincent valve was found to be higher than that of the Jellyfish valve. However, for all the operating conditions tested here, the Jellyfish valve showed superior hydrodynamic performance in terms of backflow and mean systolic pressure as well as energy losses.

  1. Adjustable valves in normal-pressure hydrocephalus: a retrospective study of 218 patients

    DEFF Research Database (Denmark)

    Zemack, G.; Rommer, Bertil Roland

    2008-01-01

    OBJECTIVE: We sought to assess the value of adjusting shunt valve opening pressure, complications, and outcomes with the use of an adjustable shunt valve in the treatment of patients with normal-pressure hydrocephalus (NPH). METHODS: In a single-center retrospective study, 231 adjustable valves...... status. The correlation of the improvement index with the size of the individual adjustments was not significant. Complications occurred in 43 (19.7%) of 218 patients, valve malfunction occurred in 3 patients (1.3%), infection occurred in 14 patients (6.4%), and nontraumatic subdural effusion occurred...

  2. Triple rotary gas lock seal system for transferring coal continuously into, or ash out of, a pressurized process vessel

    Energy Technology Data Exchange (ETDEWEB)

    Enright, F.J.; Seidl, R.M.

    1981-01-13

    A multiple rotary gas lock apparatus using a buffer seal gas is disclosed to enable the transfer of solid materials into or out of a pressurized process containing high temperature, flammable or toxic gases. The buffer seal gas, has a pressure higher than the process pressure and is introduced between two series connected gas locks; this prevents process gas backflow to the feed system. Buffer seal leakage gas from the first pair of gas locks and air from a third gas lock are removed from an opening in a connection between the pair of gas locks and the third gas lock at subatmospheric pressure. This system enables control and usuage of toxic or flammable gases as a buffer for mixing compatibility with the process gas when a suitable inert gas is not available. It also prevents the flow of any toxic gas to the worker environment.

  3. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    Science.gov (United States)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Rivera, Andrew; Birdsell, Dawn N.; Wagner, David M.; Zenhausern, Frederic

    2015-12-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30-100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis.

  4. Priming the Ahmed Glaucoma Valve: pressure required and effect of overpriming.

    Science.gov (United States)

    Cheng, Jason; Abolhasani, Milad; Beltran-Agullo, Laura; Moss, Edward Bram; Buys, Yvonne M; Trope, Graham E

    2015-01-01

    To determine the pressure required to prime an Ahmed Glaucoma Valve (AGV) and determine whether the valve can be damaged by "over-priming pressure." Three AGVs, a syringe pump, and a manometer were used to assess priming pressure. Balanced salt solution was pumped through the AGV tube at increasing pressures until a jet of fluid was seen to eject from the AGV, as per manufacturer instructions. This was repeated 3 times for 3 different virgin AGVs giving the "priming pressure." A second experiment used the same experimental set up to determine the "over-priming pressure" on 3 other AGVs. Fluid was pumped through the AGV at increasing pressures until evidence of damage was seen. The valve function was assessed before and after the "over-priming" stress test. Valve function was determined by the closing pressure, which is the pressure at which the valve closes and fluid was no longer seen passing through the valve. The priming pressure in the 3 AGVs was 2844, 3154, and 3051 mm Hg (mean, 3017±158 mm Hg). The maximum pressure generated using the syringe pump was 10,860, 10,343, and 10,860 mm Hg (mean, 10,688±299 mm Hg). No damage was observed in the valve mechanism. AGV closing pressure before the "over-priming" stress test was 8, 6, and 13 mm Hg and after the stress test was 6, 7, and 13 mm Hg. This study demonstrates that the priming pressure is consistent at around 3000 mm Hg. In addition, over-priming is not likely to damage or disturb the closing pressure.

  5. Rankine cycle condenser pressure control using an energy conversion device bypass valve

    Science.gov (United States)

    Ernst, Timothy C; Nelson, Christopher R; Zigan, James A

    2014-04-01

    The disclosure provides a waste heat recovery system and method in which pressure in a Rankine cycle (RC) system of the WHR system is regulated by diverting working fluid from entering an inlet of an energy conversion device of the RC system. In the system, an inlet of a controllable bypass valve is fluidly coupled to a working fluid path upstream of an energy conversion device of the RC system, and an outlet of the bypass valve is fluidly coupled to the working fluid path upstream of the condenser of the RC system such that working fluid passing through the bypass valve bypasses the energy conversion device and increases the pressure in a condenser. A controller determines the temperature and pressure of the working fluid and controls the bypass valve to regulate pressure in the condenser.

  6. Safety life cycle analysis applied to the engineering of pressure relief valves in process plants

    OpenAIRE

    Basco Montia, Josep

    2016-01-01

    Chemical plants and other industrial installations process and store hazardous materials, which represent a certain risk to people, equipment and the environment. Overpressure is one of the most common upsets in process plants and relief devices (pressure relief valves, rupture discs, overpressure-vacuum valves) are required on process equipment to prevent internal pressures from rising to levels, which could cause catastrophic equipment failure. They are the ultimate line of protection again...

  7. Analysis of pressure safety valves for fire protection on offshore oil and gas installations

    DEFF Research Database (Denmark)

    Bjerre, Michael; Eriksen, Jacob G.I.; Andreasen, Anders

    2017-01-01

    The effectiveness of fire Pressure Safety Valves (PSV) has been investigated when offshore process equipment is exposed to a fire. Simulations of several typical offshore pressure vessels have been performed using the commercial software VessFire. The pressure vessels are exposed to a small jet f...

  8. Decoupling Analysis on Pressure Fluctuation and Needle Valve Response for High Pressure Common Rail Injector

    Directory of Open Access Journals (Sweden)

    Hao Wang

    2017-01-01

    Full Text Available In the process of multiple injections, the influence of different injections makes the controlling of cycle fuel injection quantity more difficult. The high pressure common rail (HPCR simulation model is established in AMESim environment. Through the method of combining numerical simulation and experiment test, it is found that the strong coupling of pressure fluctuation and needle valve response is the fundamental reason, which leads to the fluctuation of main injection fuel quantity (MIFQ with dwell time (DT. The result shows that the largest fluctuation quantity is 3.6mm3 when the reference value of main injection is 60.0mm3. Non-damping LC hydraulic system model is also established. Through the analysis of the model, reducing the length-diameter ratio of internal oil duct and the delivery chamber volume are decoupling methods to the strong coupling.

  9. A Respiratory Airway-Inspired Low-Pressure, Self-Regulating Valve for Drip Irrigation

    Science.gov (United States)

    Wang, Ruo-Qian; Winter, Amos G.; GEAR Lab Team

    2015-11-01

    One of the most significant barriers to achieving large-scale dissemination of drip irrigation is the cost of the pump and power system. An effective means of reducing power consumption is by reducing pumping pressure. The principle source of pressure drop in a drip system is the high flow resistance in the self-regulating flow resistors installed at the outlets of the pips, which evenly distribute water over a field. Traditional architectures require a minimum pressure of ~1 bar to maintain a constant flow rate; our aim is to reduce this pressure by 90% and correspondingly lower pumping power to facilitate the creation of low-cost, off-grid drip irrigation systems. This study presents a new Starling resistor architecture that enables the adjustment of flow rate with a fixed minimum pressure demand of ~0.1 bar. A Starling resistor is a flexible tube subjected to a transmural pressure, which collapses the tube to restrict flow. Our design uses a single pressure source to drive flow through the flexible tube and apply a transmural pressure. Flow into the flexible tube is restricted with a needle valve, to increase the transmural pressure. Using this device, a series of experiments were conducted with different flexible tube diameters, lengths and wall thickness. We found that the resistance of the needle valve changes flow rate but not the minimum transmural pressure required to collapse the tube. A lumped-parameter model was developed to capture the relationships between valve openings, pressure, and flow rates.

  10. Assessing Optimal Blood Pressure in Patients With Asymptomatic Aortic Valve Stenosis

    DEFF Research Database (Denmark)

    Nielsen, Olav W; Sajadieh, Ahmad; Sabbah, Muhammad

    2016-01-01

    BACKGROUND: Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. METHODS: A total of 1767 patients with asymptomatic aortic...

  11. Can postoperative mean transprosthetic pressure gradient predict survival after aortic valve replacement?

    NARCIS (Netherlands)

    Koene, Bart M.; Hamad, Mohamed A. Soliman; Bouma, Wobbe; Mariani, Massimo A.; Peels, Kathinka C.; van Dantzig, Jan-Melle; van Straten, Albert H.

    In this study, we sought to determine the effect of the mean transprosthetic pressure gradient (TPG), measured at 6 weeks after aortic valve replacement (AVR) or AVR with coronary artery bypass grafting (CABG) on late all-cause mortality. Between January 1998 and March 2012, 2,276 patients (mean age

  12. The clinical application and nursing experience of adjustable shunt valve in treatment for patients with normal pressure hydrocephalus

    Directory of Open Access Journals (Sweden)

    YANG Li-rong

    2012-02-01

    Full Text Available Objective To introduce the application of adjustable shunt valve in treatment for patients with normal pressure hydrocephalus. Methods Twenty-four patients with normal pressure hydrocephalus implanted adjustable shunt valve underwent ventriculo-peritoneal shunt surgery and nursing care. Results After operation, cerebrospinal pressure was regulated for 0-6 (1.88 ± 1.52 times. Clinical symptoms were improved, especially in gait disturbance. Conclusion Treatment of normal pressure hydrocephalus with adjustable shunt valve can alleviate symptoms of hydrocephalus. It is especially suitable for patients with short course and secondary normal hydrocephalus patients.

  13. Measurements of intraperitoneal pressure and the development of a feedback control valve for regulating pressure during flexible transgastric surgery (NOTES).

    Science.gov (United States)

    Bergström, Maria; Swain, Paul; Park, Per-Ola

    2007-07-01

    High intraabdominal pressures during laparoscopy (greater than 15 mm Hg) are dangerous. Pressures developed during translumenal endosurgery when using flexible endoscopes without feed-back regulation are unknown. To measure and control intraabdominal pressures during transgastric endosurgery. In a blinded study, intraabdominal pressures during unregulated transgastric cholecystectomy and tubal ligation were measured by using Veress needles in 5 pigs (group 1). The accessory channel valve of a double-channel gastroscope was modified to allow measurement and control of intraabdominal pressures with a laparoscopic insufflator. This was tested prospectively in another blinded study in 5 pigs (group 2) that underwent identical procedures to those in group 1, with independent Veress needle pressure measurements. This ethically approved study was performed in an experimental surgical operating theater. Transgastric cholecystectomy (n=4) and tubal resection (n=6). Intraabdominal pressure measurements during transgastric endosurgery, with and without feed-back control. The mean (standard deviation) number of pressure measurements per procedure greater than 20 mm Hg was 11+/-1.41 in group 1 and 0+/-0 in group 2 (PFeedback pressure regulation through a modified valve prevented overinflation.

  14. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  15. Pressure drop and temperature rise in He II flow in round tubes, Venturi flowmeters and valves

    Science.gov (United States)

    Walstrom, P. L.; Maddocks, J. R.

    1988-01-01

    Pressure drops in highly turbulent He II flow were measured in round tubes, valves, and Venturi flowmeters. Results are in good agreement with single-phase flow correlations for classical fluids. The temperature rise in flow in a round tube was measured, and found to agree well with predictions for isenthalpic expansion. Cavitation was observed in the venturis under conditions of low back pressure and high flow rate. Metastable superheating of the helium at the venturi throat was observed before the helium made a transition to saturation pressure.

  16. A pressure-driven capillary electrophoretic system with injection valve sampling.

    Science.gov (United States)

    Han, Chao; Sun, Jiannan; Liu, Jinhua; Cheng, Heyong; Wang, Yuanchao

    2015-01-07

    To improve repeatability and efficiency and to simplify the operation procedure of capillary electrophoresis (CE), a pressurized CE system (p-CE) with injection valve sampling was developed. It consisted of one high-pressure pump, a six-port injection valve, a PEEK cross, a separation and back pressure capillary, an ultraviolet-visible detector and a high voltage power supply. The pressure-driven flow ranging from 4.5 nL min(-1) to 0.81 μL min(-1) in the separation capillary was produced by splitting to the flow from the high-pressure pumps (0.005-0.4 mL min(-1)). Nano-volume sample injection (system, the new commercial capillary could be directly used without any wash, and the capillary-flush process between runs was also eliminated. In this case, the analytes were driven toward the outlet of the separation capillary by the pressurized flow, the electric field force and minute electroosmotic flow, and they were separated owing to the electrophoretic mobility. The p-CE system allows for the independent variation of the pressurized flow rate and electrical field and electrophoretic separation of good repeatability (below 3%) under high electrical fields (500-1000 V cm(-1)) and flow rate gradient modes. The feasibility of the p-CE system in real analysis was demonstrated by iodate quantification in iodized table salts. The separation of iodide and iodate was realized within 0.3 min, proving its high analytical speed.

  17. Proximity Effects in Bilayer Graphene on Monolayer WSe2 : Field-Effect Spin Valley Locking, Spin-Orbit Valve, and Spin Transistor

    Science.gov (United States)

    Gmitra, Martin; Fabian, Jaroslav

    2017-10-01

    Proximity orbital and spin-orbit effects of bilayer graphene on monolayer WSe2 are investigated from first principles. We find that the built-in electric field induces an orbital band gap of about 10 meV in bilayer graphene. Remarkably, the proximity spin-orbit splitting for holes is 2 orders of magnitude—the spin-orbit splitting of the valence band at K is about 2 meV—more than for electrons. Effectively, holes experience spin valley locking due to the strong proximity of the lower graphene layer to WSe2 . However, applying an external transverse electric field of some 1 V /nm , countering the built-in field of the heterostructure, completely reverses this effect and allows, instead of holes, electrons to be spin valley locked with 2 meV spin-orbit splitting. Such a behavior constitutes a highly efficient field-effect spin-orbit valve, making bilayer graphene on WSe2 a potential platform for a field-effect spin transistor.

  18. Deposition of elemental sulfur in city gate Pressure Control Valves (PCVs)

    Energy Technology Data Exchange (ETDEWEB)

    Quinto, Thiago C. do; Veiga, Leandro S. da; Silva, Marcos J.M. da; Lemos, Marcelo C. de; Goncalves, Luciane T. [PETROBRAS Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-12-19

    Deposition of elemental sulfur has been observed in city gate pressure control valves (PCV s), a phenomenon that causes operational problems in these facilities. This article discusses the problems caused by this deposition, especially in pilots of pressure control valves. While passing through PCV s, the flow of natural gas is subjected to a sharp drop in temperature due to the reduction of pressure (Joule-Thompson). When this happens, the elemental sulfur that is in balance with the flow of natural gas is deposited inside the PCV s and the obstacles ahead. Since PCV s are self-operated and use natural gas as the working fluid, the elemental sulfur is also deposited in the pilots as well. Elemental sulfur in powder form has very small particles - around 20 {mu}m - that prevent the perfect operation of the small moving parts of pilots. Because of this, the affected pilot cannot operate the PCV satisfactorily to regulate the pressure of the natural gas supplied to the customer. There are two possible consequences of this situation: when the customer increases consumption, the pressure will decline to less than below the limit established under the supply contract, which can lead to fines; and the pressure can rise above the limit tolerated by pipes, which can lead to dangerous ruptures. (author)

  19. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig......In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about...

  20. The Analysis of Loop Seal Purge Time for the KHNP Pressurizer Safety Valve Test Facility Using the GOTHIC Code

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Young Ae; Kim, Chang Hyun; Kweon, Gab Joo; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The pressurizer safety valves (PSV) in Pressurized Water Reactors are required to provide the overpressure protection for the Reactor Coolant System (RCS) during the overpressure transients. Korea Hydro and Nuclear Power Company (KHNP) plans to build the PSV test facility for the purpose of providing the PSV pop-up characteristics and the loop seal dynamics for the new safety analysis. When the pressurizer safety valve is mounted in a loop seal configuration, the valve must initially pass the loop seal water prior to popping open on steam. The loop seal in the upstream of PSV prevents leakage of hydrogen gas or steam through the safety valve seat. This paper studies on the loop seal clearing dynamics using GOTHIC-7.2a code to verify the effects of loop seal purge time on the reactor coolant system overpressure.

  1. A jazz-based approach for optimal setting of pressure reducing valves in water distribution networks

    Science.gov (United States)

    De Paola, Francesco; Galdiero, Enzo; Giugni, Maurizio

    2016-05-01

    This study presents a model for valve setting in water distribution networks (WDNs), with the aim of reducing the level of leakage. The approach is based on the harmony search (HS) optimization algorithm. The HS mimics a jazz improvisation process able to find the best solutions, in this case corresponding to valve settings in a WDN. The model also interfaces with the improved version of a popular hydraulic simulator, EPANET 2.0, to check the hydraulic constraints and to evaluate the performances of the solutions. Penalties are introduced in the objective function in case of violation of the hydraulic constraints. The model is applied to two case studies, and the obtained results in terms of pressure reductions are comparable with those of competitive metaheuristic algorithms (e.g. genetic algorithms). The results demonstrate the suitability of the HS algorithm for water network management and optimization.

  2. Assessment of trans-aortic pressure gradient using a coronary pressure wire in patients with mechanical aortic and mitral valve prostheses.

    Science.gov (United States)

    Kherada, Nisharahmed; Brenes, Juan Carlos; Kini, Annapoorna S; Dangas, George D

    2017-03-15

    Accurate evaluation of trans-aortic valvular pressure gradients is challenging in cases where dual mechanical aortic and mitral valve prostheses are present. Non-invasive Doppler echocardiographic imaging has its limitations due to multiple geometric assumptions. Invasive measurement of trans-valvular gradients with cardiac catheterization can provide further information in patients with two mechanical valves, where simultaneous pressure measurements in the left ventricle and ascending aorta must be obtained. Obtaining access to the left ventricle via the mitral valve after a trans-septal puncture is not feasible in the case of a concomitant mechanical mitral valve, whereas left ventricular apical puncture technique is associated with high procedural risks. Retrograde crossing of a bileaflet mechanical aortic prosthesis with standard catheters is associated with the risk of catheter entrapment and acute valvular regurgitation. In these cases, the assessment of trans-valvular gradients using a 0.014˝ diameter coronary pressure wire technique has been described in a few case reports. We present the case of a 76-year-old female with rheumatic valvular heart disease who underwent mechanical aortic and mitral valve replacement in the past. She presented with decompensated heart failure and echocardiographic findings suggestive of elevated pressure gradient across the mechanical aortic valve prosthesis. The use of a high-fidelity 0.014˝ diameter coronary pressure guidewire resulted in the detection of a normal trans-valvular pressure gradient across the mechanical aortic valve. This avoided a high-risk third redo valve surgery in our patient. © 2017 Wiley Periodicals, Inc. © 2017 Wiley Periodicals, Inc.

  3. Development of high pressure-high vacuum-high conductance piston valve for gas-filled radiation detectors

    Science.gov (United States)

    Prasad, D. N.; Ayyappan, R.; Kamble, L. P.; Singh, J. P.; Muralikrishna, L. V.; Alex, M.; Balagi, V.; Mukhopadhyay, P. K.

    2008-05-01

    Gas-filled radiation detectors need gas filling at pressures that range from few cms of mercury to as high as 25kg/cm2 at room temperature. Before gas-filling these detectors require evacuation to a vacuum of the order of ~1 × 10-5 mbar. For these operations of evacuation and gas filling a system consisting of a vacuum pump with a high vacuum gauge, gas cylinder with a pressure gauge and a valve is used. The valve has to meet the three requirements of compatibility with high-pressure and high vacuum and high conductance. A piston valve suitable for the evacuation and gas filling of radiation detectors has been designed and fabricated to meet the above requirements. The stainless steel body (80mm×160mm overall dimensions) valve with a piston arrangement has a 1/2 inch inlet/outlet opening, neoprene/viton O-ring at piston face & diameter for sealing and a knob for opening and closing the valve. The piston movement mechanism is designed to have minimum wear of sealing O-rings. The valve has been hydrostatic pressure tested up to 75bars and has Helium leak rate of less than 9.6×10-9 m bar ltr/sec in vacuum mode and 2×10-7 mbar ltr/sec in pressure mode. As compared to a commercial diaphragm valve, which needed 3 hours to evacuate a 7 litre chamber to 2.5×10-5 mbar, the new valve achieved vacuum 7.4×10-6mbar in the same time under the same conditions.

  4. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  5. Ten years of clinical experience in the use of fixed-pressure versus programmable valves: a retrospective study of 159 patients.

    Science.gov (United States)

    Mpakopoulou, Maria; Brotis, Alexandros G; Gatos, Haralampos; Paterakis, Konstantinos; Fountas, Kostas N

    2012-01-01

    The aim of this study was to present our 10-year experience with the use of fixed-pressure and programmable valves in the treatment of adult patients requiring cerebrospinal fluid (CSF) diversion. Patients (n = 159; 89 male and 70 female) suffering from hydrocephalus of various causes underwent CSF shunt implantation. Forty fixed-pressure and 119 programmable valves were initially implanted. The observed revision rate was 40% in patients with fixed-pressure valves. In 20% of these patients, a revision due to valve mechanism malfunction was undertaken, and the initial valve was replaced with a programmable one. The revision rate in the adjustable-pressure valve subgroup was 20%. The infection rate for the fixed-pressure and programmable valve subgroups were 3%, and 1.7%, respectively. Similarly, subdural fluid collections were noticed in 17% and 4% of patients with fixed-pressure valves and programmable valves, respectively. The revision and over-drainage rates were significantly lower when using programmable valves, and thus, this type of valve is preferred whenever CSF has to be diverted.

  6. Investigation Of Adhesion Formation In New Stainless Steel Trim Spring Operated Pressure Relief Valves

    Energy Technology Data Exchange (ETDEWEB)

    Gross, Robert E. [Savannah River Site (SRS), Aiken, SC (United States); Bukowski, Julia V. [Villanova University, Villanova, PA (United States); Goble, William M. [exida, Sellersville, PA (United States)

    2013-04-16

    Examination of proof test data for new (not previously installed) stainless steel (SS) trim spring operated pressure relief valves (SOPRV) reveals that adhesions form between the seat and disc in about 46% of all such SOPRV. The forces needed to overcome these adhesions can be sufficiently large to cause the SOPRV to fail its proof test (FPT) prior to installation. Furthermore, a significant percentage of SOPRV which are found to FPT are also found to ''fail to open'' (FTO) meaning they would not relief excess pressure in the event of an overpressure event. The cases where adhesions result in FTO or FPT appear to be confined to SOPRV with diameters < 1 in and set pressures < 150 psig and the FTO are estimated to occur in 0.31% to 2.00% of this subpopulation of SS trim SOPRV. The reliability and safety implications of these finding for end-users who do not perform pre-installation testing of SOPRV are discussed.

  7. Control methods and valve arrangement for start-up and shutdown of pressurized combustion and gasification systems integrated with a gas turbine

    Science.gov (United States)

    Provol, Steve J.; Russell, David B.; Isaksson, Matti J.

    1994-01-01

    A power plant having a system for converting coal to power in a gas turbine comprises a coal fed pressurized circulating bed for converting coal to pressurized gases, a gas turbine having a compressor for pressurizing air for the pressurized circulating bed and expander for receiving and expanding hot combustion gases for powering a generator, a first fast acting valve for controlling the pressurized air, a second fast acting valve means for controlling pressurized gas from the compressor to the expander.

  8. VALIDATION OF SPRING OPERATED PRESSURE RELIEF VALVE TIME TO FAILURE AND THE IMPORTANCE OF STATISTICALLY SUPPORTED MAINTENANCE INTERVALS

    Energy Technology Data Exchange (ETDEWEB)

    Gross, R; Stephen Harris, S

    2009-02-18

    The Savannah River Site operates a Relief Valve Repair Shop certified by the National Board of Pressure Vessel Inspectors to NB-23, The National Board Inspection Code. Local maintenance forces perform inspection, testing, and repair of approximately 1200 spring-operated relief valves (SORV) each year as the valves are cycled in from the field. The Site now has over 7000 certified test records in the Computerized Maintenance Management System (CMMS); a summary of that data is presented in this paper. In previous papers, several statistical techniques were used to investigate failure on demand and failure rates including a quantal response method for predicting the failure probability as a function of time in service. The non-conservative failure mode for SORV is commonly termed 'stuck shut'; industry defined as the valve opening at greater than or equal to 1.5 times the cold set pressure. Actual time to failure is typically not known, only that failure occurred some time since the last proof test (censored data). This paper attempts to validate the assumptions underlying the statistical lifetime prediction results using Monte Carlo simulation. It employs an aging model for lift pressure as a function of set pressure, valve manufacturer, and a time-related aging effect. This paper attempts to answer two questions: (1) what is the predicted failure rate over the chosen maintenance/ inspection interval; and do we understand aging sufficient enough to estimate risk when basing proof test intervals on proof test results?

  9. Pressure Model of Control Valve Based on LS-SVM with the Fruit Fly Algorithm

    Directory of Open Access Journals (Sweden)

    Huang Aiqin

    2014-07-01

    Full Text Available Control valve is a kind of essential terminal control component which is hard to model by traditional methodologies because of its complexity and nonlinearity. This paper proposes a new modeling method for the upstream pressure of control valve using the least squares support vector machine (LS-SVM, which has been successfully used to identify nonlinear system. In order to improve the modeling performance, the fruit fly optimization algorithm (FOA is used to optimize two critical parameters of LS-SVM. As an example, a set of actual production data from a controlling system of chlorine in a salt chemistry industry is applied. The validity of LS-SVM modeling method using FOA is verified by comparing the predicted results with the actual data with a value of MSE 2.474 × 10−3. Moreover, it is demonstrated that the initial position of FOA does not affect its optimal ability. By comparison, simulation experiments based on PSO algorithm and the grid search method are also carried out. The results show that LS-SVM based on FOA has equal performance in prediction accuracy. However, from the respect of calculation time, FOA has a significant advantage and is more suitable for the online prediction.

  10. THE EFFECTS OF MAINTENANCE ACTIONS ON THE PFDavg OF SPRING OPERATED PRESSURE RELIEF VALVES

    Energy Technology Data Exchange (ETDEWEB)

    Harris, S.; Gross, R.

    2014-04-01

    The safety integrity level (SIL) of equipment used in safety instrumented functions is determined by the average probability of failure on demand (PFDavg) computed at the time of periodic inspection and maintenance, i.e., the time of proof testing. The computation of PFDavg is generally based solely on predictions or estimates of the assumed constant failure rate of the equipment. However, PFDavg is also affected by maintenance actions (or lack thereof) taken by the end user. This paper shows how maintenance actions can affect the PFDavg of spring operated pressure relief valves (SOPRV) and how these maintenance actions may be accounted for in the computation of the PFDavg metric. The method provides a means for quantifying the effects of changes in maintenance practices and shows how these changes impact plant safety.

  11. A double-blind randomized trial on the clinical effect of different shunt valve settings in idiopathic normal pressure hydrocephalus.

    Science.gov (United States)

    Farahmand, Dan; Sæhle, Terje; Eide, Per Kristian; Tisell, Magnus; Hellström, Per; Wikkelsö, Carsten

    2016-02-01

    The study aim was to examine the effect of gradually reducing the opening pressure on symptoms and signs in the shunt treatment of idiopathic normal pressure hydrocephalus (iNPH). In this prospective double-blinded, randomized, controlled, double-center study on patients with iNPH, a ventriculoperitoneal shunt with an adjustable Codman Medos Valve was implanted in 68 patients randomized into 2 groups. In 1 group (the 20-4 group) the valve setting was initially set to 20 cm H2O and gradually reduced to 4 cm H2O over the course of the 6-month study period. In the other group (the 12 group), the valve was kept at a medium level of 12 cm H2O during the whole study period. All patients were clinically evaluated using 4 tests preoperatively as well as postoperatively at 1, 2, 3, 4, and 6 months. The test scores between the 2 groups (20-4 and 12) were compared for each clinical evaluation. Fifty-five patients (81%) were able to complete the study. There were no significant differences between the 2 groups (20-4 and 12) preoperatively or at any time postoperatively. Both groups exhibited significant clinical improvement after shunt insertion at all valve settings compared with the preoperative score, with the greatest improvement observed at the first postoperative evaluation. The clinical improvement was significant within the first 3 months, and thereafter no significant improvement was seen in either group. Gradual reduction of the valve setting from 20 to 4 cm H2O did not improve outcome compared with a fixed valve setting of 12 cm H2O. Improvement after shunt surgery in iNPH patients was evident within 3 months, irrespective of valve setting.

  12. Functional Heart Valve Scaffolds Obtained by Complete Decellularization of Porcine Aortic Roots in a Novel Differential Pressure Gradient Perfusion System.

    Science.gov (United States)

    Sierad, Leslie Neil; Shaw, Eliza Laine; Bina, Alexander; Brazile, Bryn; Rierson, Nicholas; Patnaik, Sourav S; Kennamer, Allison; Odum, Rebekah; Cotoi, Ovidiu; Terezia, Preda; Branzaniuc, Klara; Smallwood, Harrison; Deac, Radu; Egyed, Imre; Pavai, Zoltan; Szanto, Annamaria; Harceaga, Lucian; Suciu, Horatiu; Raicea, Victor; Olah, Peter; Simionescu, Agneta; Liao, Jun; Movileanu, Ionela; Harpa, Marius; Simionescu, Dan Teodor

    2015-12-01

    There is a great need for living valve replacements for patients of all ages. Such constructs could be built by tissue engineering, with perspective of the unique structure and biology of the aortic root. The aortic valve root is composed of several different tissues, and careful structural and functional consideration has to be given to each segment and component. Previous work has shown that immersion techniques are inadequate for whole-root decellularization, with the aortic wall segment being particularly resistant to decellularization. The aim of this study was to develop a differential pressure gradient perfusion system capable of being rigorous enough to decellularize the aortic root wall while gentle enough to preserve the integrity of the cusps. Fresh porcine aortic roots have been subjected to various regimens of perfusion decellularization using detergents and enzymes and results compared to immersion decellularized roots. Success criteria for evaluation of each root segment (cusp, muscle, sinus, wall) for decellularization completeness, tissue integrity, and valve functionality were defined using complementary methods of cell analysis (histology with nuclear and matrix stains and DNA analysis), biomechanics (biaxial and bending tests), and physiologic heart valve bioreactor testing (with advanced image analysis of open-close cycles and geometric orifice area measurement). Fully acellular porcine roots treated with the optimized method exhibited preserved macroscopic structures and microscopic matrix components, which translated into conserved anisotropic mechanical properties, including bending and excellent valve functionality when tested in aortic flow and pressure conditions. This study highlighted the importance of (1) adapting decellularization methods to specific target tissues, (2) combining several methods of cell analysis compared to relying solely on histology, (3) developing relevant valve-specific mechanical tests, and (4) in vitro testing

  13. Performance of the fixed pressure valve with antisiphon device SPHERA® in the treatment of normal pressure hydrocephalus and prevention of overdrainage

    Directory of Open Access Journals (Sweden)

    Renan M. Pereira

    2015-01-01

    Full Text Available ABSTRACT Normal pressure hydrocephalus (NPH is characterized by the triad of gait apraxia, dementia and urinary incontinence associated with ventriculomegaly and normal pressure of cerebrospinal fluid. Treatment is accomplished through the implantation of a ventricular shunt (VPS, however some complications are still frequent, like overdrainage due to siphon effect. This study analyses the performance of a valve with anti-siphon device (SPHERA® in the treatment of patients with NPH and compares it with another group of patients with NPH who underwent the same procedure without anti-siphon mechanism (PS Medical® valve. 30 patients were consecutively enrolled in two groups with 15 patients each and followed clinically and radiologically for 1 year. Patients submitted to VPS with SPHERA® valve had the same clinical improvement as patients submitted to VPS with PS Medical®. However, complications and symptomatology due to overdrainage were significantly lower in SPHERA® group, suggesting it as a safe tool to treat NPH.

  14. How Heart Valves Evolve to Adapt to an Extreme-Pressure System

    DEFF Research Database (Denmark)

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik

    2017-01-01

    than those of calves. The elastin contents of the pulmonary valves (2.5%) and aortic valves (1.5%) were also higher in giraffes. CONCLUSIONS: The greater strength of the giraffe aortic valve is most likely due to a compact collagen construction. Both, collagen and elastin contents were higher...

  15. CFD analysis with fluid-structure interaction of opening high-pressure safety valves

    NARCIS (Netherlands)

    Beune, A.; Kuerten, Johannes G.M.; van Heumen, M.P.C.

    2012-01-01

    A multi-mesh numerical valve model has been developed to analyze the opening characteristic of highpressure safety valves. Newton’s law and the CFD result for the flow force are used to model the movement of the valve. In incompressible transient flow simulations a large force rise and collapse is

  16. Numerical simulation of mould filling process for pressure plate and valve handle in LFC

    Directory of Open Access Journals (Sweden)

    Jiang Junxia

    2010-11-01

    Full Text Available In lost foam casting (LFC, the distribution of polymer beads during the bead filling process is not uniform, and the collision between polymer beads determines the distribution of two-phase flow of gas and solid. The interaction between the gas and solid phases reveals as coupling effect of the force that gas exerts on particles or vice versa, or that among particles. The gas-solid flow in filling process is nonlinearity, which makes the coupling effect an essential point to carry out a simulation properly. Therefore, information of each particle’s motion is important for acquiring the law of filling process. In bead filling process, compressed air is pressed into mold cavity, and discharged from gas vent, creating a pressure difference between outer and inner space near the gas vent. This pressure difference directly changes the spatial distribution and motion trace of gas and solid phases. In this paper, Discrete Element Method (DEM and Computational Fluid Dynamics (CFD are employed to simulate the fluid dynamic character based on Newton’s Third Law of Motion. The simulation results of some casting products such as pressure plate and valve handle are compared with the result obtained from practical experiment in order to test the feasibility of DEM. The comparison shows that this DEM method can be a very promising tool in the mould filling simulation of beads’ movement.

  17. Performance of fixed-pressure valve with antisiphon device SPHERA® in hydrocephalus treatment and overdrainage prevention

    Directory of Open Access Journals (Sweden)

    Fernando Campos Gomes Pinto

    2012-09-01

    Full Text Available Patients with hydrocephalus and risk factors for overdrainage may be submitted to ventricular shunt (VS implant with antisiphon device. The objective of this study was to prospectively evaluate for two years the clinical and tomographic results of the implant of fixed-pressure valves with antisiphon device SPHERA® in 35 adult patients, with hydrocephalus and risk factors for overdrainage. Of these, 3 had congenital hydrocephalus in adult patients with very dilated ventricles (Evans index >50%, 3 had symptomatic overdrainage after previous VS implant (subdural hematoma, hygroma or slit ventricle syndrome, 1 had previous chronic subdural hematoma, 15 had normal pressure hydrocephalus with final lumbar pressure <5 cm H2O after tap test (40 mL, 6 had pseudotumor cerebri, and 7 had hydrocephalus due to other causes. Clinical improvement was observed and sustained in 94.3% of the patients during the two-year period with no computed tomography (CT evidence of hypo or overdrainage, and no immediate early or late significant complications.

  18. Cause Analysis of Pressure Plate Breakage of Valve Limit Switch in Turbine Bypass System of Nuclear Power Plant

    Science.gov (United States)

    Li, Nan; Wang, Ming chang; Guan, Jian jun; Li, Guo dong

    2017-07-01

    The limit switch plates of nuclear power plant unit 1 in the turbine bypass system valve are finding multiple fractures. On the basis of metallographic analysis and vibration analysis, the stress state of the pressure plate is simulated and calculated. The results show that there are some creases in the original plate of the limit switch and the installation error of the pressure plate is the main reason for the break.

  19. Marmet Locks and Dam, Kanawha River, West Virginia

    Science.gov (United States)

    2015-07-01

    lapse video systems and an underwater remotely operated vehicle . The purpose of this monitoring study was to determine if the project is...longitudinal culvert system, and Stoney gate valves. The lock was monitored using time-lapse video systems and an underwater remotely operated vehicle . The...culvert system experienced peak average velocities of 18 feet per second, although no adverse pressures were found. A remotely operated vehicle

  20. Analysis of operational methane emissions from pressure relief valves from biogas storages of biogas plants.

    Science.gov (United States)

    Reinelt, Torsten; Liebetrau, Jan; Nelles, Michael

    2016-10-01

    The study presents the development of a method for the long term monitoring of methane emissions from pressure relief valves (PRV(1)) of biogas storages, which has been verified during test series at two PRVs of two agricultural biogas plants located in Germany. The determined methane emission factors are 0.12gCH4kWhel(-1) (0.06% CH4-loss, within 106days, 161 triggering events, winter season) from biogas plant A and 6.80/7.44gCH4kWhel(-1) (3.60/3.88% CH4-loss, within 66days, 452 triggering events, summer season) from biogas plant B. Besides the operational state of the biogas plant (e.g. malfunction of the combined heat and power unit), the mode of operation of the biogas flare, which can be manually or automatically operated as well as the atmospheric conditions (e.g. drop of the atmospheric pressure) can also affect the biogas emission from PRVs. Copyright © 2016 Elsevier Ltd. All rights reserved.

  1. Mitral valve regurgitation

    Science.gov (United States)

    ... around the valve. You are at risk for mitral valve regurgitation if you have: Coronary heart disease and high blood pressure Infection of the heart valves Mitral valve prolapse (MVP) Rare conditions, such as untreated syphilis or Marfan ... heart disease. This is a complication of untreated strep throat ...

  2. A micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    NARCIS (Netherlands)

    Groen, Maarten; Brookhuis, Robert Anton; van Houwelingen, M.J.; Brouwer, Dannis Michel; Lötters, Joost Conrad; Wiegerink, Remco J.

    2013-01-01

    We have designed and fabricated the first single-wafer proportional micro control valve with built-in capacitive dis-placement sensing. The displacement sensor can facilitate high-speed active proportional control of gas flow through the valve. This is an essential requirement for non-invasive blood

  3. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    NARCIS (Netherlands)

    Groen, Maarten; Wu, Kai; Brookhuis, Robert Anton; van Houwelingen, Marc J.; Brouwer, Dannis Michel; Lötters, Joost Conrad; Wiegerink, Remco J.

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve.

  4. Simulation analysis of the influence of working medium pressure of dust removal system on dust deposition characteristics in butterfly valve region

    Directory of Open Access Journals (Sweden)

    Lixin WANG

    2016-08-01

    Full Text Available Dust of blast furnace gas deposits easily on the bottom of seat sealing surface of the tri-eccentric butterfly valve, which causes serious stuck and damage of the valve plate, thereby affects blast furnace product and brings great economic loss. To reduce the dust deposition, a kind of automatic dust removal system is designed and its efficacy is simulated. Based on FLUENT module of ANSYS Workbench, as well as standard k-ε turbulence model and DPM model, simulation analysis of the influence of 3 inlet pressures (0.25,0.30,0.35 of working medium (N2 in dust removal system and 2 different valve plate jaw openings (45°,90° on the dust deposition trajectory in butterfly valve region are conducted, and the influence mechanism of inlet pressure on the dust deposition is analyzed. The results show that the dust removal system can reduce the dust deposition under five combined conditions except under the condition of a valve plate jaw opening of 45°and an inlet pressure of 0.25 MPa. The dust removal system has much better effect under the following conditions: valve plate jaw opening of 45° and inlet pressure of 0.30 MPa, or valve plate jaw opening of 90° and inlet pressure of 0.25 MPa.

  5. Perioperative Use of Bispectral Monitor (BIS) for a Pressure Ulcer patient with Lock-In Syndrome (LIS)

    Science.gov (United States)

    Yoo, Christine; Ayello, Elizabeth A.; Robins, Bryan; Salamanca, Victor R.; Bloom, Marc J.; Linton, Patrick; Brem, Harold; O'Neill, Daniel K.

    2013-01-01

    The bispectral (BIS) monitor uses brain electroencephalographic data to measure depth of sedation and pharmacological response during anesthetic procedures. In this case, the BIS monitor was used for another purpose, to demonstrate postoperatively to the nursing staff that a patient with history of locked-in syndrome (LIS), who underwent pressure ulcer debridement, had periods of wakefulness and apparent sensation, even with his eyes closed. Furthermore, as patients with LIS can feel pain, despite being unable to move, local block or general anesthesia should be provided for sharp surgical debridement and other painful procedures. This use of the BIS has shown that as a general rule, the staff should treat the patient as though he might be awake and sensate even if he does not open his eyes or move his limbs. Our goal was to continuously monitor pain level and communicate these findings to the entire wound team, ie anesthesiologists, surgeons, and nurses. PMID:25252146

  6. Locking plate external fixation and negative pressure wound therapy for treatment of a primary infection in a closed clavicle fracture.

    Science.gov (United States)

    Kenyon, Robert M; Morrissey, David I; Molony, Diarmuid C; Quinlan, John Francis

    2016-11-28

    Infection in a clavicle fracture is uncommon, but remains a challenging problem. A paucity of soft tissue coverage often combined with significant displacement and interfragmentary movement add complexity to an already difficult situation for effective infection treatment. External fixation in principle offers a means of achieving fracture stability, while the infection is being eradicated. We present the case of a closed clavicle fracture, initially treated conservatively, that presented 5 weeks later with infection. The fracture was definitively treated with external fixation using a locking plate positioned superficially to the skin, plus negative pressure wound therapy and subsequent secondary closure and antibiotic therapy. This case illustrates a novel method of treatment in this unusual presentation that was well tolerated by the patient and resulted in a good clinical outcome. 2016 BMJ Publishing Group Ltd.

  7. Water pressure and ground vibrations induced by water guns near Bandon Road Lock and Dam and Lemont, Illinois

    Science.gov (United States)

    Adams, Ryan F.; Koebel, Carolyn M.; Morrow, William S.

    2018-02-13

    Multiple geophysical sensors were used to characterize the underwater pressure field and ground vibrations of a seismic water gun and its suitability to deter the movement of Asian carps (particularly the silver [Hypophthalmichthys molitrix] and bighead [Hypophthalmichthys nobilis] carps) while ensuring the integrity of surrounding structures. The sensors used to collect this information were blast-rated hydrophones, surface- and borehole-mounted geophones, and fixed accelerometers.Results from two separate studies are discussed in this report. The Brandon Road study took place in May 2014, in the Des Plaines River, in a concrete-walled channel downstream of the Brandon Road Lock and Dam near Joliet, Illinois. The Lemont study took place in June 2014, in a segment of the dolomite setblock-lined Chicago Sanitary and Ship Canal near Lemont, Illinois.Two criteria were evaluated to assess the potential deterrence to carp migration, and to minimize the expected effect on nearby structures from discharge of the seismic water gun. The first criterion was a 5-pound-per-square-inch (lb/in2) limit for dynamic underwater pressure variations. The second criterion was a maximum velocity and acceleration disturbance of 0.75 inch per second (in/s) for sensitive machinery (such as the lock gates and pumps) and 2.0 in/s adjacent to canal walls, respectively. The criteria were based on previous studies of fish responses to dynamic pressure variations, and effects of vibrations on the structural integrity of concrete walls.The Brandon Road study evaluated the magnitude and extent of the pressure field created by two water gun configurations in the concrete-walled channel downstream of the lock where channel depths ranged from 11 to 14 feet (ft). Data from a single 80-cubic-inch (in³) water gun set at 6 ft below water surface (bws) produced a roughly cylindrical 5-lb/in2 pressure field 20 ft in radius, oriented vertically, with the radius decreasing to less than 15 ft at the water

  8. Pulsed Phase Lock Loop Device for Monitoring Intracranial Pressure During Space Flight

    Science.gov (United States)

    Ueno, Toshiaki; Macias, Brandon R.; Yost, William T.; Hargens, Alan R.

    2003-01-01

    We have developed an ultrasonic device to monitor ICP waveforms non-invasively from cranial diameter oscillations using a NASA-developed pulsed phase lock loop (PPLL) technique. The purpose of this study was to attempt to validate the PPLL device for reliable recordings of ICP waveforms and analysis of ICP dynamics in vivo. METHODS: PPLL outputs were recorded in patients during invasive ICP monitoring at UCSD Medical Center (n=10). RESULTS: An averaged linear regression coefficient between ICP and PPLL waveform data during one cardiac cycle in all patients is 0.88 +/- 0.02 (mean +/- SE). Coherence function analysis indicated that ICP and PPLL waveforms have high correlation in the lst, 2nd, and 3rd harmonic waves associated with a cardiac cycle. CONCLUSIONS: PPLL outputs represent ICP waveforms in both frequency and time domains. PPLL technology enables in vivo evaluation of ICP dynamics non-invasively, and can acquire continuous ICP waveforms during spaceflight because of compactness and non-invasive nature.

  9. Standard Practice for Installation, Inspection, and Maintenance of Valve-body Pressure-relief Methods for Geothermal and Other High-Temperature Liquid Applications

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2003-01-01

    1.1 This practice covers installation, inspection, and maintenance of valve body cavity pressure relief methods for valves used in geothermal and other high-temperature liquid service. The valve type covered by this practice is a design with an isolated body cavity such that when the valve is in either the open or closed position pressure is trapped in the isolated cavity, and there is no provision to relieve the excess pressure internally. 1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  10. A Gustilo type IIIB open forearm fracture treated by negative pressure wound therapy and locking compression plates: a case report.

    Science.gov (United States)

    Takeuchi, Naohide; Mae, Takao; Hotokezaka, Shunsuke; Sasaki, Kosuke; Matsushita, Akinobu; Miake, Go; Kuchiishi, Rintaro; Noguchi, Yasuo

    2011-10-01

    A 91-year-old female sustained injuries to her left forearm while walking across a crosswalk. X-rays showed left radial shaft and ulna shaft fractures, and the injury was a type IIIB open fracture. On the day of admission, irrigation and debridement of the open wound, and temporary fixation of the radius and ulna using an external fixator and a Kirschner wire were peformed. Six days after the surgery, we used negative pressure wound therapy (NPWT) using the V.A.C.ATS system for the open wound. Thirteen days after the first surgery, definitive fixation was performed by using locking compression plates, and full thickness skin grafting was undertaken for the open wound. NPWT is a treatment that accelerates the wound healing process through the delivery of continuous subatmospheric pressure within a closed environment. In our case, we could reduce the healing period of the soft tissue and could convert to the definitive fixation in a timely fashion. NPWT is thought to be a useful adjunct in the management of the soft tissues of open fractures.

  11. Laser-frequency locking using light-pressure-induced spectroscopy in a calcium beam

    NARCIS (Netherlands)

    Mollema, A. K.; Wansbeek, L. W.; Willmann, L.; Jungmann, K.; Timmermans, R. G. E.; Hoekstra, R.

    We demonstrate a spectroscopy method that can be applied in an atomic beam, light-pressure-induced spectroscopy (LiPS). A simple pump and probe experiment yields a dispersivelike spectroscopy signal that can be utilized for laser frequency stabilization. The underlying principles are discussed and

  12. Application of RELAP5/MOD3.3 to Calculate Thermal Hydraulic Behavior of the Pressurizer Safety Valve Performance Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Kim, Young Ae; Oh, Seung Jong; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The increase of the acceptance tolerance of Pressurizer Safety Valve (PSV) test is vital for the safe operation of nuclear power plants because the frequent tests may make the valves decrepit and become a cause of leak. Recently, Korea Hydro and Nuclear Power Company (KHNP) is building a PSV performance test facility to provide the technical background data for the relaxation of the acceptance tolerance of PSV including the valve pop-up characteristics and the loop seal dynamics (if the plant has the loop seal in the upstream of PSV). The discharge piping and supports must be designed to withstand severe transient hydrodynamic loads when the safety valve actuates. The evaluation of hydrodynamic loads is a two-step process: first the thermal hydraulic behavior in the piping must be defined, and then the hydrodynamic loads are calculated from the thermal hydraulic parameters such as pressure and mass flow. The hydrodynamic loads are used as input to the structural analysis.

  13. Perioperative use of bispectral (BIS) monitor for a pressure ulcer patient with locked-in syndrome (LIS).

    Science.gov (United States)

    Yoo, Christine; Ayello, Elizabeth A; Robins, Bryan; Salamanca, Victor R; Bloom, Marc J; Linton, Patrick; Brem, Harold; O'Neill, Daniel K

    2014-10-01

    The bispectral (BIS) monitor uses brain electroencephalographic data to measure the depth of sedation and pharmacological response during anaesthetic procedures. In this case, the BIS monitor was used for another purpose, to demonstrate postoperatively to the nursing staff that a patient with history of locked-in syndrome (LIS), who underwent pressure ulcer debridement, had periods of wakefulness and apparent sensation, even with his eyes closed. Furthermore, as patients with LIS can feel pain, despite being unable to move, local block or general anaesthesia should be provided for sharp surgical debridement and other painful procedures. This use of the BIS has shown that as a general rule, the staff should treat the patient as though he might be awake and sensate even if he does not open his eyes or move his limbs. The goal of this study was to continuously monitor pain level and communicate these findings to the entire wound team, i.e. anaesthesiologists, surgeons and nurses. © 2012 The Authors. International Wound Journal © 2012 Medicalhelplines.com Inc and John Wiley & Sons Ltd.

  14. 46 CFR 154.345 - Air locks.

    Science.gov (United States)

    2010-10-01

    ... mechanically ventilated to make the pressure in the space greater than that in the air lock; and (2) Has a... when the pressure in the space falls to or below the pressure in the air lock. ... a gas-safe space. (b) Each air lock must: (1) Consist of two steel doors, at least 1.5 m (4.9 ft...

  15. How Heart Valves Evolve to Adapt to an Extreme-Pressure System

    DEFF Research Database (Denmark)

    Amstrup Funder, Jonas; Christian Danielsen, Carl; Baandrup, Ulrik

    2017-01-01

    by failure tests. Thickness measurements and analyses of elastin and collagen content were also made. Valve specimens were stained with hematoxylin and eosin, elastic van Gieson stain, Masson's trichrome and Fraser-Lendrum stain, as well as immunohistochemical reactions for morphological examinations...

  16. Noninvasive measurements of intramuscular pressure using pulsed phase-locked loop ultrasound for detecting compartment syndromes: a preliminary report.

    Science.gov (United States)

    Wiemann, John M; Ueno, Toshiaki; Leek, Bryan T; Yost, William T; Schwartz, Alexandra K; Hargens, Alan R

    2006-07-01

    To develop a human model for compartment tamponade and test the efficacy of ultrasonic pulsed phase-locked loop (PPLL) fascial displacement waveform analysis for noninvasive measurement of intramuscular pressure (IMP). Human subject experiment. University Level 1 trauma center. Nine male and 1 female volunteers (age 20 to 59),3 male acute compartment syndrome (ACS) patients (age 31 to 38). Thigh tourniquet was inflated in a stepwise fashion from 40 to 100 mm Hg to increase IMP transiently in volunteers. Invasive IMP by slit catheter and PPLL fascial displacement waveform in volunteers with model ACS and patients with ACS. In the model compartment tamponade group, thigh cuff occlusion increased IMP in the anterior compartment from a mean of 12.1 mm Hg (SE = 1.5) to a mean of 27.4 mm Hg (SE = 2.4, N = 8, P displacement waveform as measured by PPLL increased from a resting mean of 1.12 (SE = 0.07) to a mean of 1.85 (SE = 0.18) under the same protocol (N = 6, P = 0.001). Combined data with compartment syndrome patients revealed linear correlation between IMP and PPLL with an R value of 0.8887. Subarterial thigh cuff pressure causes a significant and transient increase in IMP, serving as a model for anterior compartment tamponade. PPLL is able to detect fascial displacement waveforms corresponding to arterial pulsation and furthermore distinguishes between normal and elevated IMP. There is a linear correlation between PPLL measurements and invasive IMP. The PPLL shows potential utility as a device for noninvasive measurement of IMP for detecting compartment syndromes.

  17. Impact characteristics for high-pressure large-flow water-based emulsion pilot operated check valve reverse opening

    Science.gov (United States)

    Liu, Lei; Huang, Chuanhui; Yu, Ping; Zhang, Lei

    2017-10-01

    To improve the dynamic characteristics and cavitation characteristics of large-flow pilot operated check valve, consider the pilot poppet as the research object, analyses working principle and design three different kinds of pilot poppets. The vibration characteristics and impact characteristics are analyzed. The simulation model is established through flow field simulation software. The cavitation characteristics of large-flow pilot operated check valve are studied and discussed. On this basis, high-pressure large-flow impact experimental system is used for impact experiment, and the cavitation index is discussed. Then optimal structure is obtained. Simulation results indicate that the increase of pilot poppet half cone angle can effectively reduce the cavitation area, reducing the generation of cavitation. Experimental results show that the pressure impact is not decreasing with increasing of pilot poppet half cone angle in process of unloading, but the unloading capacity, response speed and pilot poppet half cone angle are positively correlated. The impact characteristics of 60° pilot poppet, and its cavitation index is lesser, which indicates 60° pilot poppet is the optimal structure, with the theory results are basically identical.

  18. Cerebrospinal fluid dynamics and long-term survival of the Strata valve in idiopathic normal pressure hydrocephalus.

    Science.gov (United States)

    Lundkvist, B; Koskinen, L O D; Birgander, R; Eklund, A; Malm, J

    2011-08-01

    Cerebrospinal fluid (CSF) dynamics and long-term shunt survival of the Strata CSF shunt were evaluated in patients with idiopathic normal pressure hydrocephalus (INPH). Seventy-two patients with INPH received a Strata valve. A CSF infusion test, neuroimaging and video recording of gait were performed at baseline and at 6 months (n = 68) after surgery. Long-term shunt survivals were obtained from patient records. The shunt survival at 1 year was 94% and at 3 years 92.5%. Forty-nine patients (72%) had an improved gait. Two patients were improved despite non-functioning shunts, indicating a possible placebo response. Nineteen patients were not improved at the 6-month follow-up. The shunt tests revealed a functioning shunt in 12; thus, unnecessary shunt revisions could be avoided. Seventeen patients showed a siphoning effect. Shunt revisions were made in six patients. Eight hygromas/subdural hematomas were found. The long-term survival of the Strata valves was good, and a concern of complications is not a reason to exclude elderly with INPH from shunt surgery. Studies are needed to evaluate pros and cons of the anti-siphon device. Using a CSF shunt test, unnecessary shunt revisions may be avoided. © 2010 John Wiley & Sons A/S.

  19. Analysis of pressure transients in Safety Injection (SI) piping for the opening cause of SKN 3 Safety Relief Valves

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Suk-Ho; Lim, Sang-Gyu; Kim, Han-Gon [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    During preoperation and tests for that, the damage of Safety Relief Valves (SRVs) located at the exit of Safety Injection Pumps (SIPs) has been observed and issued recently. To resolve this issue, the opening cause of SRVs was examined from system design, piping design and operating condition. SRV performs the function of thermal relief to protect the over-pressure depending on the temperature increase in the isolated piping. We recognized that the thermal expansion did not result in the opening of SRV because there was not the cause increasing the temperature in piping at that time. In addition, it was examined that there wasn't the external cause increasing the pressure in piping to the set pressure (144.0kg/m{sup 2}) of SRV. To confirm this, mini-flow tests for SIP performance were carried out again through enough air venting in the early of 2015. As shown in table 1, the results following SIPs startup were reasonable. Otherwise, maximum pressure was greater than 142.0 kg/m{sup 2} and the fluctuation of pressure was also greater than 10.0 kg/m{sup 2} in the results of 2014 having the possibility of air present in piping and the damage of SRV. So, the objective of this paper is to evaluate pressure transients depending upon air present in SI piping as the opening cause of SKN 3 SRVs. The damage of SRVs located at the exit of SIP has been observed during pre-operation and tests of SKN 3. According to the possibility of air present in SI piping, its effect for pressure transient was evaluated at the same condition using RELAP5 code. The evaluation results for various cases demonstrate that the compression and expansion of trapped air in piping following SIP startup happen and have an effect on the opening of SRV by inducing the fluctuation of pressure and over-pressure in excess of set pressure. Also, the sensitivity results for the amount of air show that the maximum pressure in SI piping is different depending upon the amount of air and the optimal amount of

  20. An improved gate valve for critical applications in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Kalsi, M.S.; Alvarez, P.D.; Wang, J.K.; Somagyi, D. [Kalsi Engineering, Inc., Sugar Land, TX (United States)] [and others

    1996-12-01

    U.S. Nuclear Regulatory Commission Generic Letters 89-10 for motor-operated valves (MOVs) and 95-07 for all power-operated valves document in detail the problems related to the performance of the safety-related valves in nuclear power plants. The problems relate to lack of reliable operation under design basis conditions including higher than anticipated stem thrust, unpredictable valve behavior, damage to the valve internals under blowdown/high flow conditions, significant degradation of performance when cycled under AP and flow, thermal binding, and pressure locking. This paper describes an improved motor-operated flexible wedge gate valve design, the GE Sentinel Valve, which is the outcome of a comprehensive and systematic development effort undertaken to resolve the issues identified in the NRC Generic Letters 89-10 and 95-07. The new design provides a reliable, long-term, low maintenance cost solution to the nuclear power industry. One of the key features incorporated in the disc permits the disc flexibility to be varied independently of the disc thickness (pressure boundary) dictated by the ASME Section III Pressure Vessel & Piping Code stress criteria. This feature allows the desired flexibility to be incorporated in the disc, thus eliminating thermal binding problems. A matrix of analyses was performed using finite element and computational fluid dynamics approaches to optimize design for stresses, flexibility, leak-tightness, fluid flow, and thermal effects. The design of the entire product line was based upon a consistent set of analyses and design rules which permit scaling to different valve sizes and pressure classes within the product line. The valve meets all of the ASME Section III Code design criteria and the N-Stamp requirements. The performance of the valve was validated by performing extensive separate effects and plant in-situ tests. This paper summarizes the key design features, analyses, and test results.

  1. 40 CFR 60.482-8 - Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or...

    Science.gov (United States)

    2010-07-01

    ... 40 Protection of Environment 6 2010-07-01 2010-07-01 false Standards: Pumps and valves in heavy liquid service, pressure relief devices in light liquid or heavy liquid service, and connectors. 60.482-8... (CONTINUED) STANDARDS OF PERFORMANCE FOR NEW STATIONARY SOURCES Standards of Performance for Equipment Leaks...

  2. Effect of pressure pulses at the interface valve on the stability of second dimension columns in online comprehensive two-dimensional liquid chromatography.

    Science.gov (United States)

    Talus, Eric S; Witt, Klaus E; Stoll, Dwight R

    2015-01-23

    Users of online comprehensive two-dimensional liquid chromatography (LCxLC) frequently acknowledge that the mechanical instability of HPLC columns installed in these systems, particularly in the second dimension, is a significant impediment to its use. Such instability is not surprising given the strenuous operating environment to which these columns are subjected, including the large number (thousands per day) of fast and large pressure pulses resulting from interface valve switches (on the timescale of tens of milliseconds) associated with very fast second dimension separations. There appear to be no published reports of systematic studies of the relationship between second dimension column lifetime and any of these variables. In this study we focused on the relationship between the lifetimes of commercially available columns and the pressure pulses observed at the inlet of the second dimension column that occur during the switching of the valve that interfaces the two dimensions of a LCxLC system. We find that the magnitude of the pressure drop at the inlet of the second dimension column during the valve switch, which may vary between 10 and 95% of the column inlet pressure, is dependent on valve switching speed and design, and has a dramatic impact on column lifetime. In the worst case, columns fail within the first few hours of use in an LCxLC system. In the best case, using a valve that exhibits much smaller pressure pulses, the same columns exhibit much improved lifetimes and have been used continuously under LCxLC conditions for several days with no degradation in performance. This result represents a first step in understanding the factors that affect second dimension column lifetime, and will significantly improve the usability of the LCxLC technique in general. Copyright © 2014 Elsevier B.V. All rights reserved.

  3. Main Oxidizer Valve Design

    Science.gov (United States)

    Addona, Brad; Eddleman, David

    2015-01-01

    A developmental Main Oxidizer Valve (MOV) was designed by NASA-MSFC using additive manufacturing processes. The MOV is a pneumatically actuated poppet valve to control the flow of liquid oxygen to an engine's injector. A compression spring is used to return the valve to the closed state when pneumatic pressure is removed from the valve. The valve internal parts are cylindrical in shape, which lends itself to traditional lathe and milling operations. However, the valve body represents a complicated shape and contains the majority of the mass of the valve. Additive manufacturing techniques were used to produce a part that optimized mass and allowed for design features not practical with traditional machining processes.

  4. A randomised trial of high and low pressure level settings on an adjustable ventriculoperitoneal shunt valve for idiopathic normal pressure hydrocephalus: results of the Dutch evaluation programme Strata shunt (DEPSS) trial.

    Science.gov (United States)

    Delwel, Ernst J; de Jong, Dirk A; Dammers, Ruben; Kurt, Erkan; van den Brink, Wimar; Dirven, Clemens M F

    2013-07-01

    In treating idiopathic normal pressure hydrocephalus (INPH) with a shunt there is always a risk of underdrainage or overdrainage. The hypothesis is tested whether patients treated using an adjustable valve preset at the highest opening pressure leads to comparable good clinical results with less subdural effusions than in a control group with an opening pressure preset at a low pressure level. A multicentre prospective randomised trial was performed on a total of 58 patients suspected of INPH. Thirty patients were assigned to (control) group 1 and received a Strata shunt (Medtronic, Goleta, USA) with the valve preset at a performance level (PL) of 1.0, while 28 patients were assigned to group 2 and received a Strata shunt with the valve preset at PL 2.5. In this group the PL was allowed to be lowered until improvement or radiological signs of overdrainage were met. Significantly more subdural effusions were observed in the improved patients of group 1. There was no statistically significant difference in improvement between both groups overall. On the basis of this multicentre prospective randomised trial it is to be recommended to treat patients with INPH with a shunt with an adjustable valve, preset at the highest opening pressure and lowered until clinical improvement or radiological signs of overdrainage occur although slower improvement and more shunt adjustments might be the consequence.

  5. Assessing Optimal Blood Pressure in Patients With Asymptomatic Aortic Valve Stenosis: The Simvastatin Ezetimibe in Aortic Stenosis Study (SEAS).

    Science.gov (United States)

    Nielsen, Olav W; Sajadieh, Ahmad; Sabbah, Muhammad; Greve, Anders M; Olsen, Michael H; Boman, Kurt; Nienaber, Christoph A; Kesäniemi, Y Antero; Pedersen, Terje R; Willenheimer, Ronnie; Wachtell, Kristian

    2016-08-09

    Evidence for treating hypertension in patients with asymptomatic aortic valve stenosis is scarce. We used data from the SEAS trial (Simvastatin Ezetimibe in Aortic Stenosis) to assess what blood pressure (BP) would be optimal. A total of 1767 patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease were analyzed. Outcomes were all-cause mortality, cardiovascular death, heart failure, stroke, myocardial infarction, and aortic valve replacement. BP was analyzed in Cox models as the cumulative average of serially measured BP and a time-varying covariate. The incidence of all-cause mortality was highest for average follow-up systolic BP ≥160 mm Hg (4.3 per 100 person-years; 95% confidence interval [CI], 3.1-6.0) and lowest for average systolic BP of 120 to 139 mm Hg (2.0 per 100 person-years; 95% CI, 1.6-2.6). In multivariable analysis, all-cause mortality was associated with average systolic BP <120 mm Hg (hazard ratio [HR], 3.4; 95% CI, 1.9-6.1), diastolic BP ≥90 mm Hg (HR, 1.8; 95% CI, 1.1-2.9), and pulse pressure <50 mm Hg (HR, 1.8; 95% CI, 1.1-2.9), with systolic BP of 120 to 139 mm Hg, diastolic BP of 70 to 79 mm Hg, and pulse pressure of 60 to 69 mm Hg taken as reference. Low systolic and diastolic BPs increased risk in patients with moderate aortic stenosis. With a time-varying systolic BP from 130 to 139 mm Hg used as reference, mortality was increased for systolic BP ≥160 mm Hg (HR, 1.7; P=0.033) and BP of 120 to 129 mm Hg (HR, 1.6; P=0.039). Optimal BP seems to be systolic BP of 130 to 139 mm Hg and diastolic BP of 70 to 90 mm Hg in these patients with asymptomatic aortic stenosis and no manifest atherosclerotic disease or diabetes mellitus. URL: http://www.clinicaltrials.gov. Unique identifier: NCT00092677. © 2016 American Heart Association, Inc.

  6. Flow-regulated versus differential pressure-regulated shunt valves for adult patients with normal pressure hydrocephalus

    DEFF Research Database (Denmark)

    Ziebell, Morten; Wetterslev, Jørn; Tisell, Magnus

    2013-01-01

    Since 1965 many ventriculo-peritoneal shunt systems have been inserted worldwide to treat hydrocephalus. The most frequent indication in adults is normal pressure hydrocephalus (NPH), a condition that can be difficult to diagnose precisely. Surgical intervention with flow-regulated and differential...

  7. Comparative effect of carperitide and furosemide on left atrial pressure in dogs with experimentally induced mitral valve regurgitation.

    Science.gov (United States)

    Suzuki, S; Fukushima, R; Yamamoto, Y; Ishikawa, T; Hamabe, L; Kim, S; Yoshiyuki, R; Fukayama, T; Machida, N; Tanaka, R

    2013-01-01

    The effects of carperitide on left atrial pressure (LAP) in dogs with mitral valve disease (mitral regurgitation, MR) have not been documented. The objective was to compare the short-term effects of carperitide versus furosemide on LAP and neurohumoral factors in MR dogs. Six healthy Beagle dogs weighing 9.8-12.6 kg (2 males and 4 females; aged 3 years) were used. Experimental, randomized, cross-over, and interventional study. Carperitide 0.1 μg/kg/min or furosemide 0.17 mg/kg/h (1 mg/kg/6 h) was administered to dogs with surgically induced MR for 6 hours, and after a 14 day wash-out period, the other drug was administered. LAP, plasma renin activity, plasma aldosterone, and echocardiographic variables were measured. Left atrial pressure was decreased similarly after the administration of carperitide 0.1 μg/kg/min and furosemide 0.17 mg/kg/h (1 mg/kg/6 h) compared with baseline in dogs with MR (Baseline 14.75 ± 3.74 mmHg, carperitide 10.24 ± 4.97 mmHg, P dogs with acute MR caused by experimental chordal rupture. Carperitide can have additional benefits from the viewpoint of minimal activation of neurohumoral factors in the treatment of dogs with MR. Additional studies in dogs with spontaneous disease are warranted. Copyright © 2013 by the American College of Veterinary Internal Medicine.

  8. A Novel Pressure Compensating Valve for Low-Cost Drip Irrigation

    Science.gov (United States)

    Winter, Amos; Wiens, Alexander

    2014-11-01

    Nearly one billion people are currently living as subsistence farmers in the developing world. Irrigation could drastically increase quality of life for these individuals by enabling them to grow more and higher value crops. However, current irrigation technologies are too costly for this economic sector, particularly in off-grid applications. The cost of an off-grid irrigation system is primarily driven by the power required to pump the water at a relatively high pressure (>1 bar). We propose a novel pressure compensating drip emitter design which allows these systems to operate at 1/10 the pressure of current products, making them economically viable in developing markets. Our proposed solution is inspired by the resonating nozzle of a deflating balloon. We use a reduced order model to understand the physical principles which drive the cyclic collapse of the balloon nozzle. This knowledge is applied to propose a pressure compensating drip emitter consisting of a simple compliant tube in series with a rigid conical diffuser. A scaling analysis is performed to determine the ideal geometry of the system and the model is applied to demonstrate that the proposed design is capable of pressure compensation in the required operation range. Preliminary experiments are presented.

  9. Intraocular pressure control after the implantation of a second Ahmed glaucoma valve.

    Science.gov (United States)

    Jiménez-Román, Jesús; Gil-Carrasco, Félix; Costa, Vital Paulino; Schimiti, Rui Barroso; Lerner, Fabián; Santana, Priscila Rezende; Vascocellos, Jose Paulo Cabral; Castillejos-Chévez, Armando; Turati, Mauricio; Fabre-Miranda, Karina

    2016-06-01

    The objective of this study is to evaluate the efficacy and safety of a second Ahmed glaucoma valve (AGV) in eyes with refractory glaucoma that had undergone prior Ahmed device implantation. This multicenter, retrospective study evaluated 58 eyes (58 patients) that underwent a second AGV (model S2-n = 50, model FP7-n = 8) due to uncontrolled IOP under maximal medical therapy. Outcome measures included IOP, visual acuity, number of glaucoma medications, and postoperative complications. Success was defined as IOP IOP (criterion 2) with or without hypotensive medications. Persistent hypotony (IOP IOP control were defined as failure. Mean preoperative IOP and mean IOPs at 12 and 30 months were 27.55 ± 1.16 mmHg (n = 58), 14.45 ± 0.83 mmHg (n = 42), and 14.81 ± 0.87 mmHg (n = 16), respectively. The mean numbers of glaucoma medications preoperatively at 12 and 30 months were 3.17 ± 0.16 (n = 58), 1.81 ± 0.2 (n = 42), and 1.83 ± 0.35 (n = 18), respectively. The reductions in mean IOP and number of medications were statistically significant at all time intervals (P IOP in eyes with uncontrolled glaucoma, and is associated with relatively few complications.

  10. Left ventricular filling pressure estimation at rest and during exercise in patients with severe aortic valve stenosis: comparison of echocardiographic and invasive measurements

    DEFF Research Database (Denmark)

    Dalsgaard, Morten; Kjaergaard, Jesper; Pecini, Redi

    2009-01-01

    BACKGROUND: The Doppler index of left ventricular (LV) filling (E/e') is recognized as a noninvasive measure for LV filling pressure at rest but has also been suggested as a reliable measure of exercise-induced changes. The aim of this study was to investigate changes in LV filling pressure......, measured invasively as pulmonary capillary wedge pressure (PCWP), at rest and during exercise to describe the relation with E/e' in patients with severe aortic stenosis. METHODS: Twenty-eight patients with an aortic valve areas

  11. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  12. Noncontacting valve-position indicator

    Science.gov (United States)

    Crovella, E. A.; Cummins, R. D.; Wada, J. M.

    1979-01-01

    Position of sealed valve or other movable part is indicated without penetrating housing. Flux from magnets connected to stem of hydraulic valve penetrates pressure wall and is sensed by Hall-effect transducer outside wall. When valve closes, moving stem and magnets, voltage from transducer decreases; thus, stem position is indicated without physical contact.

  13. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve

    Directory of Open Access Journals (Sweden)

    Christophe Gutfrind

    2016-05-01

    Full Text Available The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP Exhaust Gas Recirculation (EGR valve for use in Internal Combustion Engines (ICEs. The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM using the FLUX-3D® software (CEDRAT, Meylan, France will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink® in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system.

  14. Mechanical Designs for Relief Valves for Cryogenic Apparatuses and Installations

    CERN Multimedia

    CERN. Geneva

    2016-01-01

    There are also pressure relief valves with warm seat available on which the set pressure is based on an adjustment of forces by permanent magnets. Pressure vessel rules allows also the choice for an active triggered pressure relief valve (Cont...

  15. Cracking a tricuspid perimount bioprosthesis to optimize a second transcatheter sapien valve-in-valve placement.

    Science.gov (United States)

    Brown, Stephen C; Cools, Bjorn; Gewillig, Marc

    2016-09-01

    Bioprosthetic valves degenerate over time. Transcatheter valve-in-valve procedures have become an attractive alternative to surgery. However, every valve increasingly diminishes the diameter of the valvar orifice. We report a 12-year-old female who had a previous transcatheter tricuspid valve-in-valve procedure; cracking the ring of a Carpentier Edwards Perimount valve by means of an ultrahigh pressure balloon allowed implantation of a further larger percutaneous valve. The advantage of this novel approach permits enlarging the inner valve diameter and may facilitate future interventions and prolong time to surgery. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  16. Locked Out.

    Science.gov (United States)

    Johansson, Veronica; Soekadar, Surjo R; Clausen, Jens

    2017-10-01

    Brain-computer interfaces (BCIs) can enable communication for persons in severe paralysis including locked-in syndrome (LIS); that is, being unable to move or speak while aware. In cases of complete loss of muscle control, termed "complete locked-in syndrome," a BCI may be the only viable solution to restore communication. However, a widespread ignorance regarding quality of life in LIS, current BCIs, and their potential as an assistive technology for persons in LIS, needlessly causes a harmful situation for this cohort. In addition to their medical condition, these persons also face social barriers often perceived as more impairing than their physical condition. Through social exclusion, stigmatization, and frequently being underestimated in their abilities, these persons are being locked out in addition to being locked-in. In this article, we (1) show how persons in LIS are being locked out, including how key issues addressed in the existing literature on ethics, LIS, and BCIs for communication, such as autonomy, quality of life, and advance directives, may reinforce these confinements; (2) show how these practices violate the United Nations Convention on the Rights of Persons with Disabilities, and suggest that we have a moral responsibility to prevent and stop this exclusion; and (3) discuss the role of BCIs for communication as one means to this end and suggest that a novel approach to BCI research is necessary to acknowledge the moral responsibility toward the end users and avoid violating the human rights of persons in LIS.

  17. Intelligent MTconnect. Eddy-Current Valve Probe Pilot Project within the High Pressure Gas Facility (HPGF) Liquid Nitrogen Evaporator Systems

    Data.gov (United States)

    National Aeronautics and Space Administration — This project will perform real-time collection of prognostic valve operational data by deploying smart eddy-current probes with the use of the MTconnect® system,...

  18. Comparative effects of amlodipine and benazepril on Left Atrial Pressure in Dogs with experimentally-induced Mitral Valve Regurgitation

    Directory of Open Access Journals (Sweden)

    Suzuki Shuji

    2012-09-01

    Full Text Available Abstract Background One of the purposes of treatment for dogs with mitral regurgitation (MR is lowering left atrial pressure (LAP. There has been few study of the amlodipine in dogs with MR and amlodipine’s effect on LAP has not been fully evaluated in a quantitative manner because of difficulties in directly measuring LAP. The objective of our study was to compare the short-term effects of amlodipine (0.2 mg/kg PO q12h vs benazepril (0.5 mg/kg PO q12h, on LAP and echocardiographic parameters in five beagle dogs with experimentally-induced MR. LAP of eight dogs that has own control were measured using radiotelemetry system at baseline and again on days 1, 2, 3, 4, 5, 6, 7 of the drug administration. Results Mean LAP decreased significantly after amlodipine (11.20 ± 4.19 mmHg vs 14.61 ± 3.81 mmHg at baseline, p  .05. LAP was lower after 7 days of amlodipine treatment than after 7 days of benazepril treatment. Significant reduction was seen for the first time 4 days after the administration amlodipine. The rate of the maximal area of the regurgitant jet signals to the left atrium area (ARJ/LAA of the amlodipine treatment was significantly lower (p  Conclusions LAP was significantly decreased after amlodipine treatment in dogs with surgically-induced MR but not after benazepril treatment. Although this study did not focus on adverse effects, amlodipine may be an effective drug for helping the patients with acute onset of severe MR, such as rupture of chordae tendinae or end stage patients were the LAP is likely to be elevated. Additional studies in clinical patients with degenerative mitral valve disease and acute chordal rupture are warranted because the blood-pressure lowering effects of amlodipine can decrease renal perfusion and this can further activate the RAAS.

  19. Valve Disease

    Science.gov (United States)

    ... See also on this site: Diseases of the Mitral Valve Diseases of the Aortic Valve Diseases of the Tricuspid ... most invasive option for the treatment of valve disease. During surgery, ... defects of the mitral valve. Replacement is used to treat any diseased ...

  20. Flow Characteristics of Butterfly Valve by PIV and CFD

    Science.gov (United States)

    Kim, S. W.; Kim, J. H.; Choi, Y. D.; Lee, Y. H.

    Butterfly valves are widely used as on-off and control valves for industrial process. The importance of butterfly valves as control valves has been increasing because the pressure loss is smaller than other types of valves and compactness is very desirable for installation. These features are desirable for saving energy and high efficiency of instruments.

  1. Assessment of a pressurizer spray valve faulty opening transient at Asco Nuclear Power Plant with RELAP5/MOD2. International Agreement Report

    Energy Technology Data Exchange (ETDEWEB)

    Reventos, F.; Baptista, J.S.; Navas, A.P.; Moreno, P. [Asociacion Nuclear Asco, Barcelona (Spain)

    1993-12-01

    The Asociacion Nuclear Asco has prepared a model of Asco NPP using RELAP5/MOD2. This model, which include thermalhydraulics, kinetics and protection and controls, has been qualified in previous calculations of several actual plant transients. One of the transients of the qualification process is a ``Pressurizer spray valve faulty opening`` presented in this report. It consists in a primary coolant depressurization that causes the reactor trip by overtemperature and later on the actuation of the safety injection. The results are in close agreement with plant data.

  2. Overdrainage of cerebrospinal fluid caused by detachment of the pressure control cam in a programmable valve after 3-tesla magnetic resonance imaging.

    Science.gov (United States)

    Watanabe, Atsushi; Seguchi, Tatsuya; Hongo, Kazuhiro

    2010-02-01

    The authors report a rare case of overdrainage of the CSF caused by the malfunction of a Codman-Hakim programmable valve (CHPV) following a 3-T MR imaging procedure. Nine years ago this 72-year-old woman underwent ventriculoperitoneal shunt placement with a CHPV system for hydrocephalus due to subarachnoid hemorrhage. The postoperative course was uneventful and the system functioned well. A radiograph obtained immediately after 3-T MR imaging revealed that the pressure control cam in the valve system was detached from the base plate. Intracranial hypotension syndrome occurred several hours after the MR imaging study, and a CT scan revealed a decrease in ventricle size. A revision of the system promptly resolved the symptoms, and a postoperative CT scan revealed that the ventricle size was restored to normal. Examination of the extracted valve showed a Y-shaped crack in the plastic housing as well as detachment of the white marker and cam from the base plate. A reduction in the power of the flat spring to press the valve ball led to CSF overdrainage because of a loss of support by the cam. Because the patient had incurred no head injury during the day and radiographic studies of the system 5 years previously had shown detachment of the white marker, damage to the system might have been caused by a past impact. These facts may indicate that the antimagnetic performance of the system could have decreased due to a previous impact and that the strong magnetic force in a 3-T MR imaging environment might have caused detachment of the cam.

  3. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  4. Phase locking of vortex cores in two coupled magnetic nanopillars

    Directory of Open Access Journals (Sweden)

    Qiyuan Zhu

    2014-11-01

    Full Text Available Phase locking dynamics of the coupled vortex cores in two identical magnetic spin valves induced by spin-polarized current are studied by means of micromagnetic simulations. Our results show that the available current range of phase locking can be expanded significantly by the use of constrained polarizer, and the vortices undergo large orbit motions outside the polarization areas. The effects of polarization areas and dipolar interaction on the phase locking dynamics are studied systematically. Phase locking parameters extracted from simulations are discussed by theoreticians. The dynamics of vortices influenced by spin valve geometry and vortex chirality are discussed at last. This work provides deeper insights into the dynamics of phase locking and the results are important for the design of spin-torque nano-oscillators.

  5. Tricuspid valve and percutaneous approach: No longer the forgotten valve!

    Science.gov (United States)

    Bouleti, Claire; Juliard, Jean-Michel; Himbert, Dominique; Iung, Bernard; Brochet, Eric; Urena, Marina; Dilly, Marie-Pierre; Ou, Phalla; Nataf, Patrick; Vahanian, Alec

    2016-01-01

    Tricuspid valve disease is mainly represented by tricuspid regurgitation (TR), which is a predictor of poor outcome. TR is usually secondary, caused by right ventricle pressure or volume overload, the leading cause being left-sided heart valve diseases. Tricuspid surgery for severe TR is recommended during left valve surgery, and consists of either a valve replacement or, most often, a tricuspid repair with or without prosthetic annuloplasty. When TR persists or worsens after left valvular surgery, redo isolated tricuspid surgery is associated with high mortality. In addition, a sizeable proportion of patients present with tricuspid surgery deterioration over time, and need a reintervention, which is associated with high morbi-mortality rates. In this context, and given the recent major breakthrough in the percutaneous treatment of aortic and mitral valve diseases, the tricuspid valve appears an appealing challenge, although it raises specific issues. The first applications of transcatheter techniques for tricuspid valve disease were valve-in-valve and valve-in-ring implantation for degenerated bioprosthesis or ring annuloplasty. Some concerns remain regarding prosthesis sizing, rapid ventricular pacing and the best approach, but these procedures appear to be safe and effective. More recently, bicuspidization using a transcatheter approach for the treatment of native tricuspid valve has been published, in two patients. Finally, other devices are in preclinical development. Copyright © 2015 Elsevier Masson SAS. All rights reserved.

  6. Heart valve surgery

    Science.gov (United States)

    Valve replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... can relieve your symptoms and prolong your life. Mechanical heart valves do not often fail. However, blood clots can ...

  7. Avoidance of transmission line pressure oscillations in discrete hydraulic systems – by shaping of valve opening characteristics

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Bech, Michael Møller

    2015-01-01

    The architecture of multi pressure line discrete fluid power force systems imposes rapid pressure shifts in the actuator volumes. These fast shifts between pressure levels often introduce pressure oscillations in the actuator chamber and connecting pipes. The topic of this paper is to perform...... pressure shifts by changing the connection between various fixed pressure lines without introducing significant pressure oscillation. As a case study a discrete force system is utilised is a Power Take Off(PTO) system of a wave energy converter. Four pressure shifting algorithms are proposed...

  8. Propellant actuated nuclear reactor steam depressurization valve

    Science.gov (United States)

    Ehrke, Alan C.; Knepp, John B.; Skoda, George I.

    1992-01-01

    A nuclear fission reactor combined with a propellant actuated depressurization and/or water injection valve is disclosed. The depressurization valve releases pressure from a water cooled, steam producing nuclear reactor when required to insure the safety of the reactor. Depressurization of the reactor pressure vessel enables gravity feeding of supplementary coolant water through the water injection valve to the reactor pressure vessel to prevent damage to the fuel core.

  9. Thermo-electric valve

    Science.gov (United States)

    Chamberland, R. R.; Stanland, A. J.

    1985-02-01

    A thermo-electric valve is described for scuttling floating devices comprising, a cylindrical sleeve affixed to and passing through a bulkhead separating a pressurized medium on one side from a lower pressure space on the other side, a piston moveably mounted within the sleeve bore and exposed to the pressurized medium having a portion thereof blocking the sleeve bore, an O-ring sealing the gap between the piston head and the sleeve bore, a fully compressed spring pressing against the piston, a rigid dielectric washer and a low power resistor holding the piston against the spring. In operation a low current is passed through the resistor, disintegrating it and releasing the spring's stored energy. This actuates the valve by expelling the piston which allows the pressurized fluid or gas to enter the lower pressure space.

  10. Testing of calibration and reconditioning of the pressurizer safety valves; Pruebas de tarado y reacondicionamiento de las valvulas de seguridad del presionador

    Energy Technology Data Exchange (ETDEWEB)

    Mediavilla, F.; Jardi, X.

    2014-07-01

    This paper presents All activities that are required in the proposal of Tecnatom as: transport of valves to the laboratory in special containers and preparation of the expedition of the radioactive packages testing of leakage of valves with nitrogen, leak and calibration with initial steam and final tests, overhaul of the valve including the process Jack and Lap and mounting and dismounting of valves in the plant. (Author)

  11. Atmospheric dispersion of natural gas from a rupture in a pressurized and valved subsea pipeline; Dispersao atmosferica de gas natural por ruptura em duto submarino pressurizado e valvulado

    Energy Technology Data Exchange (ETDEWEB)

    Soares, Fabio Coimbra Moreira de Macedo; Medeiros, Jose Luiz de; Araujo, Ofelia de Queiroz Fernandes [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil). Escola de Quimica. Dept. de Engenharia Quimica

    2008-04-15

    This paper presents a simplified approach to the problem of transient atmospheric dispersion of natural gas released accidentally under the ocean, caused by leaks in pressurized subsea pipelines. The model aims to estimate the transient spatial distribution of gas concentration in the atmosphere for subsequent risk analysis. In this scenario, shut-off valves are used to rapidly isolate the damaged stretch of the gas pipeline (pipeline shutdown). The analysis considers the transient behavior of the remaining inventory inside the pipes through a release-by-leakage model, and the subsequent effect on the atmosphere surrounding the epicenter of release. There are also scenarios formulated with occurrences of numerous ruptures, synchronized or not, with known spatial distribution. The spatial-temporal model of atmospheric dispersion employed is based on the resolution of the tridimensional diffusion equation under turbulence in semi-infinite domains. The model includes appropriate resources to deal with: an ample range of atmospheric conditions; different wind velocities; transient conditions of gas released into the atmosphere (i.e., outflow, pressure, and temperature); many depths of emission; multi-source configuration of release. In this work a simulation tool in MATLAB environment was developed for the analyses of scenarios of transient dispersion of gas into the atmosphere. In the case of ruptures in subsea gas lines, this tool is useful to determine the conditions of maximum risk on production platforms situated close to the occurrence, as well as the impact of the localization of the shut-off valves in the release transient behavior. (author)

  12. Reducing leaks in water distribution networks. Controlling pressure by means of automatic hydraulic valves; Reduccion de fugas en redes de distribucion de agua. Control de la presion mediante valvulas hidraulicas automaticas

    Energy Technology Data Exchange (ETDEWEB)

    Singla Font, S.

    2005-07-01

    Any water distribution network, bet it of drinking water or irrigation water, always loses an inevitable amount. One of the main ways to reduce leaks is to optimise the pressure in the network by means of hydraulic valves with different types of control devices. These can be either completely hydraulic or supplemented by electronic systems. (Author)

  13. Lost Treasures: Locks

    Directory of Open Access Journals (Sweden)

    Semra SARAÇOĞLU ÇELİK

    2015-03-01

    Full Text Available Locks have been widely used in our daily life. In this paper an attempt is made to study the history of locks and to give the kinds of locks and samples from past to present: Ancient Egypt, Chinese, Iran, Roman, Turk-Islam Locks. Ancient locks relied on the pin tumbler principle that many of today's locks use. Many early Roman Keys were made to be worn as rings, because clothing of Romans did not have pockets. It is hoped that this article can simulate more research and publications regarding the development of ancient locks.

  14. Recent NRC research activities addressing valve and pump issues

    Energy Technology Data Exchange (ETDEWEB)

    Morrison, D.L.

    1996-12-01

    The mission of the U.S. Nuclear Regulatory Commission (NRC) is to ensure the safe design, construction, and operation of commercial nuclear power plants and other facilities in the U.S.A. One of the main roles that the Office of Nuclear Regulatory Research (RES) plays in achieving the NRC mission is to plan, recommend, and implement research programs that address safety and technical issues deemed important by the NRC. The results of the research activities provide the bases for developing NRC positions or decisions on these issues. Also, RES performs confirmatory research for developing the basis to evaluate industry responses and positions on various regulatory requirements. This presentation summarizes some recent RES supported research activities that have addressed safety and technical issues related to valves and pumps. These activities include the efforts on determining valve and motor-operator responses under dynamic loads and pressure locking events, evaluation of monitoring equipment, and methods for detecting and trending aging of check valves and pumps. The role that RES is expected to play in future years to fulfill the NRC mission is also discussed.

  15. Exhaust gas bypass valve control for thermoelectric generator

    Science.gov (United States)

    Reynolds, Michael G; Yang, Jihui; Meisner, Greogry P.; Stabler, Francis R.; De Bock, Hendrik Pieter Jacobus; Anderson, Todd Alan

    2012-09-04

    A method of controlling engine exhaust flow through at least one of an exhaust bypass and a thermoelectric device via a bypass valve is provided. The method includes: determining a mass flow of exhaust exiting an engine; determining a desired exhaust pressure based on the mass flow of exhaust; comparing the desired exhaust pressure to a determined exhaust pressure; and determining a bypass valve control value based on the comparing, wherein the bypass valve control value is used to control the bypass valve.

  16. CFD- and Bernoulli-based pressure drop estimates: A comparison using patient anatomies from heart and aortic valve segmentation of CT images.

    Science.gov (United States)

    Weese, Jürgen; Lungu, Angela; Peters, Jochen; Weber, Frank M; Waechter-Stehle, Irina; Hose, D Rodney

    2017-06-01

    An aortic valve stenosis is an abnormal narrowing of the aortic valve (AV). It impedes blood flow and is often quantified by the geometric orifice area of the AV (AVA) and the pressure drop (PD). Using the Bernoulli equation, a relation between the PD and the effective orifice area (EOA) represented by the area of the vena contracta (VC) downstream of the AV can be derived. We investigate the relation between the AVA and the EOA using patient anatomies derived from cardiac computed tomography (CT) angiography images and computational fluid dynamic (CFD) simulations. We developed a shape-constrained deformable model for segmenting the AV, the ascending aorta (AA), and the left ventricle (LV) in cardiac CT images. In particular, we designed a structured AV mesh model, trained the model on CT scans, and integrated it with an available model for heart segmentation. The planimetric AVA was determined from the cross-sectional slice with minimum AV opening area. In addition, the AVA was determined as the nonobstructed area along the AV axis by projecting the AV leaflet rims on a plane perpendicular to the AV axis. The flow rate was derived from the LV volume change. Steady-state CFD simulations were performed on the patient anatomies resulting from segmentation. Heart and valve segmentation was used to retrospectively analyze 22 cardiac CT angiography image sequences of patients with noncalcified and (partially) severely calcified tricuspid AVs. Resulting AVAs were in the range of 1-4.5 cm2 and ejection fractions (EFs) between 20 and 75%. AVA values computed by projection were smaller than those computed by planimetry, and both were strongly correlated (R2 = 0.995). EOA values computed via the Bernoulli equation from CFD-based PD results were strongly correlated with both AVA values (R2 = 0.97). EOA values were ∼10% smaller than planimetric AVA values. For EOA values < 2.0 cm2 , the EOA was up to ∼15% larger than the projected AVA. The presented segmentation algorithm

  17. Butterfly valve of all rubber lining type

    Energy Technology Data Exchange (ETDEWEB)

    Shimada, Shosaku; Nakatsuma, Sumiya (Kubota Ltd., Osaka (Japan)); Sasaki, Iwao; Aoki, Naoshi

    1982-08-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported.

  18. A calculation of the differential pressure of MOV(Moter Operated Valve) using Flowmaster and SFM code

    Energy Technology Data Exchange (ETDEWEB)

    Rey, H. K.; Park, S. K.; Kim, D. W.; Kang, S. C.; Jung, H. K.; Park, S. K. [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    2000-10-01

    Comparisons of the calculation of the differential pressure through four MOV's between Flowmaster code and SFM model has been presented. The Flowmaster and SFM model basically use 1-D steady-state equation, but for the transient analysis, the Flowmaster uses Joukowsky equation considering the effect of fluid velocity variation and wave speed, while, the SFM model uses quasi-steady equation including fluid inertia effect due to pipe inertia. The maximum differential pressures in opening stroke are almost the same between Flowmaster and SFM model, because the two code have the same steady-state equation. For closing stroke, however, the maximum differential pressure is somewhat different, the Flowmaster code shows higher large estimation than SFM code.

  19. Computational Fluid Dynamics Analysis of Butterfly Valve Performance Factors

    OpenAIRE

    Del Toro, Adam

    2012-01-01

    Butterfly valves are commonly used in industrial applications to control the internal flow of both compressible and incompressible fluids. A butterfly valve typically consists of a metal disc formed around a central shaft, which acts as its axis of rotation. As the valve's opening angle is increased from 0 degrees (fully closed) to 90 degrees (fully open), fluid is able to more readily flow past the valve. Characterizing a valve's performance factors, such as pressure drop, hydrodynamic torqu...

  20. Use of external lumbar cerebrospinal fluid drainage and lumboperitoneal shunts with Strata NSC valves in idiopathic normal pressure hydrocephalus: a single-center experience.

    Science.gov (United States)

    Nakajima, Madoka; Miyajima, Masakazu; Ogino, Ikuko; Sugano, Hidenori; Akiba, Chihiro; Domon, Naoko; Karagiozov, Kostadin L; Arai, Hajime

    2015-03-01

    In Japan, idiopathic normal pressure hydrocephalus (iNPH) currently is treated mainly with lumboperitoneal (LP) shunts. Our aim was to evaluate whether LP shunting via the use of Medtronic Strata NSC programmable valves was as effective as ventriculoperitoneal shunting in the treatment of patients with iNPH from the perspectives of safety and symptomatic improvement rate. The clinical records of 51 iNPH patients (mean age, 75 years; males, 29), who underwent placement of Medtronic Strata NSC LP shunt systems were reviewed retrospectively as a cohort. LP shunting was evaluated with the modified Rankin Scale, the Japan Normal-Pressure Hydrocephalus Grading Scale, the Mini-Mental State Examination, the Frontal Assessment Battery, and the Trail-Making Test A as outcome measures. Modified Rankin Scale scores improved from 3.2 to 2.2 (P < 0.01), indicating a 64% response rate 12 months after treatment. Total Japan Normal-Pressure Hydrocephalus Grading Scale scores decreased from 6.5 to 4.0 (P < 0.01), indicating a response rate of 81%. Mini-Mental State Examination scores improved from 22.2 to 25.4 (P < 0.01), Frontal Assessment Battery scores improved from 11.7 to 13.4 (P < 0.05), and Trail-Making Test A scores improved from 122.3 to 112.7 (P = 0.60). During the 12-month follow-up period, complications requiring surgery were observed in 6 cases (11.8%). LP shunts showed effectiveness rates that were similar to those of ventriculoperitoneal shunts. Despite the relatively high complication rate, LP shunts can be recommended for the treatment of patients with iNPH because of their minimal invasiveness and lack of lethal complications. Copyright © 2015 The Authors. Published by Elsevier Inc. All rights reserved.

  1. Overview of locking systems

    Energy Technology Data Exchange (ETDEWEB)

    Gee, K.T.; Scott, S.H.; Wilde, M.G. [Sandia National Labs., Albuquerque, NM (United States); Highland, S.E. [Albuquerque Safe Co., Albuquerque, NM (United States)

    1993-12-01

    The purpose of this document is to present technical information that should be useful for understanding and applying locking systems for physical protection and control. There are major sections on hardware for locks, vaults, safes, and security containers. Other topics include management of lock systems and safety considerations. This document also contains notes on standards and specifications and a glossary.

  2. Conical Seat Shut-Off Valve

    Science.gov (United States)

    Farner, Bruce

    2013-01-01

    A moveable valve for controlling flow of a pressurized working fluid was designed. This valve consists of a hollow, moveable floating piston pressed against a stationary solid seat, and can use the working fluid to seal the valve. This open/closed, novel valve is able to use metal-to-metal seats, without requiring seat sliding action; therefore there are no associated damaging effects. During use, existing standard high-pressure ball valve seats tend to become damaged during rotation of the ball. Additionally, forces acting on the ball and stem create large amounts of friction. The combination of these effects can lead to system failure. In an attempt to reduce damaging effects and seat failures, soft seats in the ball valve have been eliminated; however, the sliding action of the ball across the highly loaded seat still tends to scratch the seat, causing failure. Also, in order to operate, ball valves require the use of large actuators. Positioning the metal-to-metal seats requires more loading, which tends to increase the size of the required actuator, and can also lead to other failures in other areas such as the stem and bearing mechanisms, thus increasing cost and maintenance. This novel non-sliding seat surface valve allows metal-to-metal seats without the damaging effects that can lead to failure, and enables large seating forces without damaging the valve. Additionally, this valve design, even when used with large, high-pressure applications, does not require large conventional valve actuators and the valve stem itself is eliminated. Actuation is achieved with the use of a small, simple solenoid valve. This design also eliminates the need for many seals used with existing ball valve and globe valve designs, which commonly cause failure, too. This, coupled with the elimination of the valve stem and conventional valve actuator, improves valve reliability and seat life. Other mechanical liftoff seats have been designed; however, they have only resulted in

  3. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  4. Investigation of Flow Structures Downstream of SAPIEN 3, CoreValve, and PERIMOUNT Magna Using Particle Image Velocimetry

    Science.gov (United States)

    Barakat, Mohammed; Lengsfeld, Corinne; Dvir, Danny; Azadani, Ali

    2017-11-01

    Transcatheter aortic valves provide superior systolic hemodynamic performance in terms of valvular pressure gradient and effective orifice area compared with equivalent size surgical bioprostheses. However, in depth investigation of the flow field structures is of interest to examine the flow field characteristics and provide experimental evidence necessary for validation of computational models. The goal of this study was to compare flow field characteristics of the three most commonly used transcatheter and surgical valves using phase-locked particle image velocimetry (PIV). 26mm SAPIEN 3, 26mm CoreValve, and 25mm PERIMOUNT Magna were examined in a pulse duplicator with input parameters matching ISO-5840. A 2D PIV system was used to obtain the velocity fields. Flow velocity and shear stress were obtained during the entire cardiac cycle. In-vitro testing showed that mean gradient was lowest for SAPIEN 3, followed by CoreValve and PERIMOUNT Magna. In all the valves, the peak jet velocity and maximum viscous shear stress were 2 m/s and 2 MPa, respectively. In conclusion, PIV was used to investigate flow field downstream of the three bioprostheses. Viscous shear stress was low and consequently shear-induced thrombotic trauma or shear-induced damage to red blood cells is unlikely.

  5. Management of central venous catheters in pediatric onco-hematology using 0.9% sodium chloride and positive-pressure-valve needleless connector.

    Science.gov (United States)

    Buchini, Sara; Scarsini, Sara; Montico, Marcella; Buzzetti, Roberto; Ronfani, Luca; Decorti, Cinzia

    2014-08-01

    To describe, in a sample of pediatric onco-hematological patients, the rate of occlusions in unused central venous catheters (CVC) flushed once a week with a 0.9% sodium chloride solution through a positive-pressure-valve needleless connector. Retrospective cohort study. Subjects aged 0-17 years were identified through a manual search in medical and nursing records and were observed for two years or until the occurrence of one of the following events: start or resume of continuous infusion; CVC removal; death. The primary study outcome was the frequency of CVC occlusion (partial or complete). Fifty-one patients were identified (median age 6 years). The median duration of follow-up was 169 days (IQR 111-305). During the follow up period, 14 patients (27%) had one CVC occlusion, in 2 cases (4%) the occlusion was complete, in 12 (23%) partial. All the occlusions were solved without the need for catheter removal. The lumen diameter ≤ 4.2 vs > 4.2 French showed a statistically significant association with occlusion at multivariate analysis (OR 4.0; 95% CI 1.1-14.7). Our findings are reassuring with respect to the management of the CVC using the adopted protocol. The study provides useful information for patient care, by verifying the performance of the adopted CVC management protocol and by identifying critical areas for nursing care. Copyright © 2014 Elsevier Ltd. All rights reserved.

  6. Mixture distribution in a multi-valve twin-spark ignition engine equipped with high-pressure multi-hole injectors

    Science.gov (United States)

    Mitroglou, N.; Arcoumanis, C.; Mori, K.; Motoyama, Y.

    2006-07-01

    Laser-induced fluorescence has been mainly used to characterise the two-dimensional fuel vapour concentration inside the cylinder of a multi-valve twin-spark ignition engine equipped with high-pressure multi-hole injectors. The effects of injection timing, in-cylinder charge motion and injector tip layout have been quantified. The flexibility in nozzle design of the multi-hole injectors has proven to be a powerful tool in terms of matching overall spray cone angle and number of holes to specific engine configurations. Injection timing was found to control spray impingement on the piston and cylinder wall, thus contributing to quick and efficient fuel evaporation. It was confirmed that in-cylinder charge motion plays a major role in engine's stable operation by assisting in the transportation of the air-fuel mixture towards the ignition locations (i.e. spark-plugs) in the way of a uniformly distributed charge or by preserving stratification of the charge depending on operating mode of the engine.

  7. Comparison of mitral valve area by pressure half-time and proximal isovelocity surface area method in patients with mitral stenosis: effect of net atrioventricular compliance.

    Science.gov (United States)

    Salem Omar, Alaa Mabrouk; Tanaka, Hidekazu; AbdelDayem, Tarek Khairy; Sadek, Ayman S; Raslaan, Halah; Al-Sherbiny, Ashraf; Yamawaki, Kohei; Ryo, Keiko; Fukuda, Yuko; Norisada, Kazuko; Tatsumi, Kazuhiro; Onishi, Tetsuari; Matsumoto, Kensuke; Kawai, Hiroya; Hirata, Ken-ichi

    2011-04-01

    The aim of this study was to test the hypothesis that, unlike calculation of the mitral valve area (MVA) with the pressure half-time method (PHT), the proximal isovelocity surface area method (PISA) is not affected by changes in net atrioventricular compliance (C(n)). We studied 51 patients with mitral stenosis (MS) from two centres. MVA was assessed with the PISA (MVA(PISA)), PHT (MVA(PHT)), and planimetry (MVA(PLN), serving as the gold standard) method. C(n) was calculated with a previously validated equation using 2D echocardiography. MVA(PISA) closely correlated with MVA(PLN) (r = 0.96, P PISA), MVA(PLN), and C(n) (r = 0.1, P = 0.388). MVA calculated with both the PISA and PHT methods correlated well with MVA calculated with the planimetry method. However, the PISA rather than PHT is recommended for patients with MS and extreme C(n) values because PISA, unlike PHT, is not affected by changes in C(n).

  8. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  9. Intraocular pressure control and corneal graft survival after implantation of Ahmed valve device in high-risk penetrating keratoplasty.

    Science.gov (United States)

    Almousa, Radwan; Nanavaty, Mayank A; Daya, Sheraz M; Lake, Damian B

    2013-08-01

    To analyze the control of intraocular pressure (IOP) and corneal graft survival after implantation of Ahmed glaucoma device (AGD) in eyes that had high-risk penetrating keratoplasty (PK). This is a retrospective noncomparative case series of 59 eyes that had high-risk PK and underwent AGD insertion. The primary outcome measures are the control of IOP between 6 and 21 mm Hg and corneal graft survival. The secondary outcome measures are risk factors associated with IOP control and corneal graft survival. The mean IOP reduced significantly after the AGD procedure (26.45 ± 6.8 mm Hg preoperatively vs. 16.85 ± 7.4 mm Hg, 16.95 ± 4.6 mm Hg, 17.97 ± 5.7 mm Hg, 15.78 ± 5.2 mm Hg, and 15.59 ± 5.5 mm Hg, at 1 month, 6 months, 1 year, 2 years, and at the last follow-up postoperatively; P IOP control was successful in 44 eyes (75.8%). IOP control was successful in 96% of the eyes at 1 year, 87% at 2 years, 83% at 3 years, and 83% at 5 years. The percentage of clear corneal grafts after 1, 2, 3, and 5 years following the AGD insertion were 87%, 77%, 65%, and 47%, respectively. Further surgery after AGD insertion was associated with 1.79 times greater risk of failure of IOP control. AGD was effective in controlling the IOP associated with high-risk PK over a 5-year period. Postvalve surgery doubles the risk of failure of IOP control.

  10. Valve's Way

    DEFF Research Database (Denmark)

    Foss, Nicolai Juul; Dobrajska, Magdalena

    2015-01-01

    to what extent it represents a new blueprint for organization design, despite it being consistent with an “egalitarian Zeitgeist” (Puranam, 2014). In fact, managerial authority may be of increasing importance rather than the opposite (Guadalupe, Li, & Wulf, 2015). Thus, Valve is, and will remain...

  11. Vacuum Valve

    CERN Multimedia

    1974-01-01

    This valve was used in the Intersecting Storage Rings (ISR) to protect against the shock waves that would be caused if air were to enter the vacuum tube. Some of the ISR chambers were very fragile, with very thin walls - a design required by physicists on the lookout for new particles.

  12. Short- to long-term results of Ahmed glaucoma valve in the management of elevated intraocular pressure in patients with pediatric uveitis.

    Science.gov (United States)

    Eksioglu, Umit; Yakin, Mehmet; Sungur, Gulten; Satana, Banu; Demirok, Gulizar; Balta, Ozgur; Ornek, Firdevs

    2017-06-01

    The aim of this study was to evaluate the long-term outcome of Ahmed glaucoma valve (AGV) implant for elevated intraocular pressure (IOP) in pediatric patients with uveitis. This was a retrospective chart review. The study included 16 eyes (11 children) with uveitis. Success was defined as having IOP between 6 and 21 mm Hg with (qualified success) or without (complete success) antiglaucoma medications and without the need for further glaucoma or tube extraction surgery. Mean age of patients at the time of AGV implantation was 14.19 ± 3.25 years. AGV implantation was the first glaucoma surgical procedure in 12 eyes (75%). Average postoperative follow-up period was 64.46 ± 33.56 months. Mean preoperative IOP was 33.50 ± 7.30 mm Hg versus 12.69 ± 3.20 mm Hg at the last follow-up visit (p AGV implantation in 1 eye. The cumulative probability of complete success was 68.8% at 6 months, 56.3% at 12 months, 49.2% at 36 months, 42.2% at 48 months, and 35.2% at 84 months, and the cumulative probability of eyes without complication was 75.0% at 6 months, 66.7% at 24 months, 58.3% at 36 months, 48.6% at 48 months and 24.3% at 108 months based on Kaplan-Meier survival analysis. Although AGV implant is an effective choice in the management of elevated IOP in pediatric uveitis, antiglaucoma medications are frequently needed for control of IOP. Tube exposure is an important complication in the long term. Differential diagnosis between relapse of uveitis and endophthalmitis is important in patients who received AGV implantation. Copyright © 2017 Canadian Ophthalmological Society. Published by Elsevier Inc. All rights reserved.

  13. Valve selection handbook engineering fundamentals for selecting the right valve design for every industrial flow application

    CERN Document Server

    Smith, Peter

    2004-01-01

    Valves are the components in a fluid flow or pressure system that regulate either the flow or the pressure of the fluid. They are used extensively in the process industries, especially petrochemical. Though there are only four basic types of valves, there is an enormous number of different kinds of valves within each category, each one used for a specific purpose. No other book on the market analyzes the use, construction, and selection of valves in such a comprehensive manner.-Covers new environmentally-conscious equipment and practices, the most important hot-button issue in the p

  14. Fluid Dynamic Characterization of a Polymeric Heart Valve Prototype (Poli-Valve) tested under Continuous and Pulsatile Flow Conditions

    Science.gov (United States)

    De Gaetano, Francesco; Serrani, Marta; Bagnoli, Paola; Brubert, Jacob; Stasiak, Joanna; Moggridge, Geoff D.; Costantino, Maria Laura

    2016-01-01

    Introduction Only mechanical and biological heart valve prostheses are currently commercially available. The former show longer durability but require anticoagulant therapy, the latter display better fluid dynamic behaviour but do not have adequate durability. New Polymeric Heart Valves (PHVs) could potentially combine the haemodynamic properties of biological valves with the durability of mechanical valves. This work presents a hydrodynamic evaluation of two groups of newly developed supra-annular tri-leaflet prosthetic heart valves made from styrenic block copolymers (SBC): Poli-Valves. Methods Two types of Poli-Valves made of SBC differing in polystyrene fraction content were tested under continuous and pulsatile flow conditions as prescribed by ISO 5840 Standard. An ad - hoc designed pulse duplicator allowed the valve prototypes to be tested at different flow rates and frequencies. Pressure and flow were recorded; pressure drops, effective orifice area (EOA), and regurgitant volume were computed to assess the valve’s behaviour. Results Both types Poli-Valves met the minimum requirements in terms of regurgitation and EOA as specified by ISO 5840 Standard. Results were compared with five mechanical heart valves (MHVs) and five tissue heart valves (THVs), currently available on the market. Conclusion Based on these results, polymeric heart valves based on styrenic block copolymers, as Poli-Valves are, can be considered as promising alternative for heart valve replacement in near future. PMID:26689146

  15. Hammock mitral valve: A rare case report

    Directory of Open Access Journals (Sweden)

    Veeresh F. Manvi

    2014-01-01

    Full Text Available Congenital mitral stenosis is a relatively rare disorder comprising 0.2% of all congenital heart defects. Hammock mitral valve producing severe mitral stenosis is a rare variant of congenital mitral stenosis. We report a 2-year-old boy who had hammock mitral valve producing severe mitral stenosis with severe pulmonary artery hypertension. He underwent successful surgical repair. Post-surgery, the mitral valve opening was adequate without residual stenosis or regurgitation. Pulmonary artery pressure had normalized. Follow-up data showed he had significant clinical and echocardiography improvement. This is the first reported case of successful surgical repair done for hammock mitral valve from our institute.

  16. 49 CFR 192.181 - Distribution line valves.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 3 2010-10-01 2010-10-01 false Distribution line valves. 192.181 Section 192.181 Transportation Other Regulations Relating to Transportation (Continued) PIPELINE AND HAZARDOUS MATERIALS SAFETY... line valves. (a) Each high-pressure distribution system must have valves spaced so as to reduce the...

  17. Butterfly valve. Spjeldventil

    Energy Technology Data Exchange (ETDEWEB)

    Cupedo, D.J.

    1984-02-06

    Butterfly valve comprising a body and a valve seat arranged therein, on which a valve member is supported. The valve member comprises an operating rod and the assembly of valve member and operating rod has a fixed pivot point at the bottom of the body. The operating rod can be moved by means of pins movable in grooves and slots in such a manner that when the valve is opened the valve member first pivots about the pivot point to lift the valve member from the seat and subsequently rotates about the pivot point to fully open the valve. 12 drawings.

  18. Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  19. Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine

    Science.gov (United States)

    Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    2000-01-01

    Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  20. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI...

  1. 33 CFR 207.718 - Navigation locks and approach channels, Columbia and Snake Rivers, Oreg. and Wash.

    Science.gov (United States)

    2010-07-01

    ... schedule and any changes to the schedule will be issued at least 30 days prior to implementation. Prior to... subject to falling overboard. (t) Handling valves, gates, bridges, and machinery. No person, unless authorized by the Lock Master, shall open or close any bridge, gate, valve, or operate any machinery in...

  2. Locke (adversaires de)

    DEFF Research Database (Denmark)

    Schøsler, Jørn

    2017-01-01

    den apologetiske kritik af John Locke i den franske modoplysning centreret om 'medødte idéer' og den 'tænkende materie'.......den apologetiske kritik af John Locke i den franske modoplysning centreret om 'medødte idéer' og den 'tænkende materie'....

  3. Holberg, lecteur de Locke

    DEFF Research Database (Denmark)

    Schøsler, Jørn

    2009-01-01

      En undersøgelse af John Lockes modtagelse i dansk Oplysningsfilosofi med særligt henblik på Holberg......  En undersøgelse af John Lockes modtagelse i dansk Oplysningsfilosofi med særligt henblik på Holberg...

  4. A New Hemostasis Valve for Neuroendovascular Procedures

    Science.gov (United States)

    Namba, K.; Song, J.K.; Niimi, Y.; Heran, N.S.; Berenstein, A.

    2007-01-01

    Summary A hemostasis valve is routinely used in neuroendovascular procedures to decrease the risk of thromboembolism1,2. Recently, a new hemostasis valve that is designed to minimize blood loss has been introduced. We report our initial experience in using this new hemostasis valve. In neuroendovascular procedures, a hemostasis valve is commonly used for continuous irrigation of guide and microcatheters to decrease the risk of thromboembolism1,2,3. A conventional hemostasis valve has a rotating seal at the end, which is turned open or closed each time a wire or microcatheter/guidewire is introduced or extracted. Often this results in significant back bleeding. When a rotating seal is adjusted suboptimally during a wire or microcatheter manipulation, leakage of pressurized saline from the end of a hemostasis valve results in stagnation of blood within a guiding catheter, which becomes a potential source of emboli during a procedure. The Guardian Haemostasis Valve (Zerusa Limited, Galway, Ireland) is a new hemostasis valve that is designed to minimize blood loss during interventional procedures by minimizing the opening time of the valve during wire or microcatheter insertion. A continuous sealing mechanism during wire or microcatheter positioning minimizes blood loss and stagnation of blood within the guide catheter. We report our initial experience with the Guardian hemostasis valve. PMID:20566129

  5. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  6. Locke on measurement.

    Science.gov (United States)

    Anstey, Peter R

    2016-12-01

    Like many virtuosi in his day, the English philosopher John Locke maintained an active interest in metrology. Yet for Locke, this was no mere hobby: questions concerning measurement were also implicated in his ongoing philosophical project to develop an account of human understanding. This paper follows Locke's treatment of four problems of measurement from the early Drafts A and B of the Essay concerning Human Understanding to the publication of this famous book and its aftermath. It traces Locke's attempt to develop a natural or universal standard for the measure of length, his attempts to grapple with the measurement of duration, as well as the problems of determining comparative measures for secondary qualities, and the problem of discriminating small differences in the conventional measures of his day. It is argued that the salient context for Locke's treatment of these problems is the new experimental philosophy and its method of experimental natural history. Copyright © 2016. Published by Elsevier Ltd.

  7. Novel passive normally closed microfluidic valve

    CSIR Research Space (South Africa)

    Land, K

    2009-09-01

    Full Text Available -8 lithography and replication molding processes. It was successfully implemented, and initial results show the relationship between the applied pressure and flow rate. In addition to being used as a toggle valve, this design also allows...

  8. Comments on compressible flow through butterfly valves

    Science.gov (United States)

    Blakenship, John G.

    In the flow analysis of process piping systems, it is desirable to treat control valves in the same way as elbow, reducers, expansions, and other pressure loss elements. In a recently reported research program, the compressible flow characteristics of butterfly valves were investigated. Fisher Controls International, Inc., manufacturer of a wide range of control valves, publishes coefficients that can be used to calculate flow characteristics for the full range of valve movement. The use is described of the manufacturer's data to calculate flow parameters as reported by the researchers who investigated compressible flow through butterfly valves. The manufacturer's data produced consistent results and can be used to predict choked flow and the pressure loss for unchoked flow.

  9. Aortic Valve Stenosis

    Science.gov (United States)

    ... rapid, fluttering heartbeat Not eating enough (mainly in children with aortic valve stenosis) Not gaining enough weight (mainly in children with aortic valve stenosis) The heart-weakening effects of aortic valve stenosis ...

  10. Design, Analysis, Prototyping, and Experimental Evaluation of an Efficient Double Coil Magnetorheological Valve

    Directory of Open Access Journals (Sweden)

    Guoliang Hu

    2014-05-01

    Full Text Available A double coil magnetorheological (MR valve with an outer annular resistance gap was designed and prototyped. The finite element modeling and analysis of double coil MR valve were carried out using ANSYS/Emag software, and the optimal magnetic field distribution and magnetic flux density of the double coil MR valve were achieved. The mechanism of the pressure drop was studied by building a mathematical model of pressure drop in the double coil MR valve. The proposed double coil MR valve was prototyped and its performance was experimentally evaluated. The new MR valve design has improved the efficiency of double coil MR valve significantly.

  11. High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Harold Schock; Farhad Jaberi; Ahmed Naguib; Guoming Zhu; David Hung

    2007-12-31

    This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when

  12. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... called stenosis). • Don’t close properly and let blood leak where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t close properly (more common in women).As pressure builds inside the left ventricle, it pushes the ...

  13. Mechanical heart valve cavitation in patients with bileaflet valves.

    Science.gov (United States)

    Johansen, Peter; Andersen, Tina S; Hasenkam, J Michael; Nygaard, Hans; Paulsen, Peter K

    2014-01-01

    Today, the quality of mechanical heart valves is quite high, and implantation has become a routine clinical procedure with a low operative mortality (mechanism found to be a possible contributor to these adverse effects is cavitation. In vitro, cavitation has been directly demonstrated by visualization and indirectly in vivo by registering of high frequency pressure fluctuations (HFPF). Tilting disc valves are thought of having higher cavitation potential than bileaflet valves due to higher closing velocities. However, the thromboembolic potential seems to be the same. Further studies are therefore needed to investigate the cavitation potential of bileaflet valves in vivo. The post processing of HFPF have shown difficulties when applied on bileaflet vavles due to asynchronous closure of the two leaflets. The aim of this study was therefore to isolate the pressure signature from each leaflet closure and perform cavitation analyses on each component. Six patients were included in the study (St. Jude Medical (n=3) and CarboMedics (n=3); all aortic bileaflet mechanical heart valves). HFPFs were recorded intraoperatively through a hydrophone at the aortic root. The pressure signature relating to the first and second leaflet closure was isolated and cavitation parameters were calculated (RMS after 50 kHz highpass filtering and signal energy). Data were averaged over 30 heart cycles. For all patients both the RMS value and signal energy of the second leaflet closure were higher than for the first leaflet closure. This indicates that the second leaflet closure is most prone to cause cavitation. Therefore, quantifying cavitation based on the HFPF related to the second leaflet closure may suggest that the cavitation potential for bileaflet valves in vivo may be higher than previous studies have suggested.

  14. In vitro evaluation of the iValve: a novel hands-free speech valve.

    Science.gov (United States)

    van der Houwen, Eduard B; van Kalkeren, Tjouwke A; Burgerhof, Johannes G M; van der Laan, Bernard F A M; Verkerke, Gijsbertus J

    2011-12-01

    We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure drops. This method makes long sentences or pauses difficult. The novel iValve is designed to allow almost natural speech, with mid-sentence pausing and whispering. The inhalation closing flows and exhalation opening pressures of 6 iValve prototype versions at different settings were compared with physiological values. The airflow resistance at inhalation was compared to physiological values and to commercial valve values. The iValve prototypes showed flow and pressure ranges in concordance with the physiological values in the literature. The airflow resistance in the breathing mode was within the physiological airflow resistance range, yet above the values from the two commercial valves. The resistance in the speaking mode was above the physiological airflow resistance range. In vitro tests show that the iValve versions can be selected and adjusted to operate within the physiological range. The airflow resistance in the breathing mode is good. In speaking mode, inhalation should, and can, be decreased. The iValve should offer the patient a more intuitively useable alternative with more dynamic speech. Its low cost allows disposability and wider use.

  15. What Is Heart Valve Disease?

    Science.gov (United States)

    ... Heart Valves Sometimes heart valves can’t be repaired and must be replaced. This surgery involves removing the faulty valve and replacing it with a man-made or biological valve. Biological valves are made ...

  16. Vehicle handling and the application of skid marks during braking with an anti-lock braking system and a sudden loss of tire pressure as a result of an accident

    Energy Technology Data Exchange (ETDEWEB)

    Grandel, J.; Zomoter, A.

    1985-11-01

    The German Motor Vehicle Inspection Association e.V. (DEKRA) and Daimler-Benz AG conducted joint testing on a Mercedes-Benz car equipped with ABS and subjected to tire blow-outs. Anti-lock braking systems have so radically altered production cars' vehicle dynamics that many questions have arisen begging further investigation. Even during a sudden loss of tire pressure, ABS makes a significant contribution towards maintaining directional control at high speeds. The vehicle remains controllable during simultaneous severe braking and a tire blow-out. Deceleration takes place at a rate slightly lower than it does when brakes are applied in cars with intact tires. As compared to reference measurements, the lowest mean deceleration measured with slit tires is lower by about 20%, although the mean deceleration of 5.7 m/sS can not be considered low in absolute terms. The earlier the tire is slit, the flatter the deceleration curve; however, it remains to be seen how the brake-control system and vehicle would react if the loss of tire pressure did not take place until much later than the brake application. The wheel with the blow-out is not controlled in a manner any different from the one with the intact tire. Immediately after loss of tire pressure, slip rises briefly, only to be counteracted by the brake-control system. When determining slip, one must bear in mind that the dynamic wheel radius becomes noticeably smaller as a result of deflation of the tire. The hig brake pressure applied during the experiments required a high control frequency. This caused the tires to leave continuous skid marks, the intensity of which dependend on the road surface. Changes in the flex mark characteristic left by the deflated tire after initiation of braking were not perceptible. The deflated tire did not slip on its rim. (orig./HW).

  17. Bicycle Parking and Locking

    DEFF Research Database (Denmark)

    Larsen, Jonas

    2017-01-01

    Cars, trains, and bicycles are designed to be on the move. Mobilities studies have theorized and analyzed these modes of transport as powerful entities slicing through, and speeding-up, cities. Yet they also stand still, being parked and locked, immobilized and secured, until their next trip....... This article contributes with new insights into parking and locking - ‘moorings’ - to cycling literature. It presents an ethnography of ‘design moorings’ and practices associated with parking and locking bikes. The main case study is the very pro-cycling city of Copenhagen. Yet to explore what is unique about...

  18. In Vitro Evaluation of the iValve : A Novel Hands-Free Speech Valve

    NARCIS (Netherlands)

    van der Houwen, E.B.; van Kalkeren, T.A.; Burgerhof, J.G.; van der Laan, B.F.; Verkerke, G.J.

    2011-01-01

    Objectives: We performed in vitro evaluation of a novel, disposable, automatic hands-free tracheostoma speech valve for laryngectomy patients based upon the principle of inhalation. The commercially available automatic speech valves close upon strong exhalation and open again when the pressure

  19. Fracturing a dysfunctional Edwards Perimount bioprosthetic valve to facilitate percutaneous valve-in-valve placement of SAPIEN 3 valve with modified delivery system.

    Science.gov (United States)

    Shahanavaz, Shabana; Rockefeller, Toby; Nicolas, Ramzi; Balzer, David

    2017-10-10

    Pulmonary valve replacement via surgical implantation of a bioprosthetic valve (BPV) is a well-established treatment for patients with dysfunctional RV outflow tracts. BPVs are prone to structural deterioration, and will eventually require replacement. Recently, percutaneous valve-in-valve (VIV) placement of transcatheter valves has established itself as a safe and effective alternative to surgical revision. Unfortunately, VIV therapy is inherently limited by the inner diameter of the BPV, which restricts the number of eligible patients. Other centers have reported on the feasibility of cracking certain BPVs with ultra high-pressure balloons in bench testing. We now report cracking an Edwards Perimount BPV in the pulmonary position to facilitate VIV placement of an Edwards SAPIEN 3. The ability to crack the Perimount valve allowed placement of a larger valve than previously considered and minimized the final valve gradient. In an effort to avoid the morbidity and mortality of surgical pulmonary valve replacement, this new strategy will expand the number of patients eligible for percutaneous VIV therapy. © 2017 Wiley Periodicals, Inc.

  20. LOCKS AND KEYS SERVICE

    CERN Multimedia

    Locks and Keys Service

    2002-01-01

    The Locks and Keys service (ST/FM) will move from building 55 to building 570 from the 2nd August to the 9th August 2002 included. During this period the service will be closed. Only in case of extreme urgency please call the 164550. Starting from Monday, 12th August, the Locks and Keys Service will continue to follow the activities related to office keys (keys and locks) and will provide the keys for furniture. The service is open from 8h30 to 12h00 and from 13h00 to 17h30. We remind you that your divisional correspondents can help you in the execution of the procedures. We thank you for your comprehension and we remain at your service to help you in solving all the matters related to keys for offices and furniture. Locks and Keys Service - ST Division - FM Group

  1. Experimental quantum data locking

    Science.gov (United States)

    Liu, Yang; Cao, Zhu; Wu, Cheng; Fukuda, Daiji; You, Lixing; Zhong, Jiaqiang; Numata, Takayuki; Chen, Sijing; Zhang, Weijun; Shi, Sheng-Cai; Lu, Chao-Yang; Wang, Zhen; Ma, Xiongfeng; Fan, Jingyun; Zhang, Qiang; Pan, Jian-Wei

    2016-08-01

    Classical correlation can be locked via quantum means: quantum data locking. With a short secret key, one can lock an exponentially large amount of information in order to make it inaccessible to unauthorized users without the key. Quantum data locking presents a resource-efficient alternative to one-time pad encryption which requires a key no shorter than the message. We report experimental demonstrations of a quantum data locking scheme originally proposed by D. P. DiVincenzo et al. [Phys. Rev. Lett. 92, 067902 (2004), 10.1103/PhysRevLett.92.067902] and a loss-tolerant scheme developed by O. Fawzi et al. [J. ACM 60, 44 (2013), 10.1145/2518131]. We observe that the unlocked amount of information is larger than the key size in both experiments, exhibiting strong violation of the incremental proportionality property of classical information theory. As an application example, we show the successful transmission of a photo over a lossy channel with quantum data (un)locking and error correction.

  2. Locke and botany.

    Science.gov (United States)

    Anstey, Peter R; Harris, Stephen A

    2006-06-01

    This paper argues that the English philosopher John Locke, who has normally been thought to have had only an amateurish interest in botany, was far more involved in the botanical science of his day than has previously been known. Through the presentation of new evidence deriving from Locke's own herbarium, his manuscript notes, journal and correspondence, it is established that Locke made a modest contribution to early modern botany. It is shown that Locke had close and ongoing relations with the Bobarts, keepers of the Oxford Botanic Garden, and that Locke distributed seeds and plant parts to other botanists, seeds of which the progeny almost certainly ended up in the most important herbaria of the period. Furthermore, it is claimed that the depth of Locke's interest in and practice of botany has a direct bearing on our understanding of his views on the correct method of natural philosophy and on the interpretation of his well known discussion of the nature of species in Book III of his Essay concerning human understanding.

  3. A Study on the Mechanism for Cavitation in the Mechanical Heart Valves with an Electrohydraulic Total Artificial Heart

    Science.gov (United States)

    Lee, Hwansung; Tsukiya, Tomonori; Homma, Akihiko; Kamimura, Tadayuki; Tatsumi, Eisuke; Taenaka, Yoshiyuki; Kitamura, Soichiro

    It has been conceived that the mechanical heart valves mounted in an artificial heart close much faster than in vivo use, resulting in cavitation bubbles formation. In this study, the mechanisms for cavitation in mechanical heart valves (MHVs) is investigated with monoleaflet and bileaflet valves in the mitral position with an electrohydraulic total artificial heart (EHTAH). The valve-closing velocity and pressure-drop through the valve were done, and a high-speed video camera was employed to investigate the mechanism for MHVs cavitation. The valve-closing velocity and pressure-drop of the bileaflet valves were less than that of the monoleaflet valves. Most of the cavitation bubbles in the monoleaflet valves were observed next to the edge of the valve stop and the inner side of the leaflet. With the bileaflet valves, cavitation bubbles were concentrated along the leaflet tip. Also, the number density of cavitation bubbles in the bileaflet valves was less than that of the monoleaflet valves. The number density of cavitation bubbles increased with an increase in the valve-closing velocity and the valve stop area. It is established that squeeze flow holds the key to cavitation in the mechanical heart valve. In a viewpoint of squeeze flow, the bileaflet valve with slow valve-closing velocity and small valve stop area, is safer to prevent of blood cell damage than the monoleaflet valves.

  4. Numerical Analysis for Structural Safety Evaluation of Butterfly Valves

    Science.gov (United States)

    Shin, Myung-Seob; Yoon, Joon-Yong; Park, Han-Yung

    2010-06-01

    Butterfly valves are widely used in current industry to control the fluid flow. They are used for both on-off and throttling applications involving large flows at relatively low operating pressure especially in large size pipelines. For the industrial application of butterfly valves, it must be ensured that the valve could be used safety under the fatigue life and the deformations produced by the pressure of the fluid. In this study, we carried out the structure analysis of the body and the valve disc of the butterfly valve and the numerical simulation was performed by using ANSYS v11.0. The reliability of valve is evaluated under the investigation of the deformation, the leak test and the durability of the valve.

  5. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  6. Remote actuated valve implant

    Energy Technology Data Exchange (ETDEWEB)

    McKnight, Timothy E.; Johnson, Anthony; Moise, Kenneth J.; Ericson, Milton Nance; Baba, Justin S.; Wilgen, John B.; Evans, Boyd Mccutchen

    2016-05-10

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  7. Tissue engineered aortic valve

    OpenAIRE

    Dohmen, P M

    2012-01-01

    Several prostheses are available to replace degenerative diseased aortic valves with unique advantages and disadvantages. Bioprotheses show excellent hemodynamic behavior and low risk of thromboembolic complications, but are limited by tissue deterioration. Mechanical heart valves have extended durability, but permanent anticoagulation is mandatory. Tissue engineering created a new generation heart valve, which overcome limitations of biological and mechanical heart valves due to remodelling,...

  8. Valve-in-valve outcome: design impact of a pre-existing bioprosthesis on the hydrodynamics of an Edwards Sapien XT valve.

    Science.gov (United States)

    Doose, Christian; Kütting, Maximilian; Egron, Sandrine; Farhadi Ghalati, Pejman; Schmitz, Christoph; Utzenrath, Marc; Sedaghat, Alexander; Fujita, Buntaro; Schmitz-Rode, Thomas; Ensminger, Stephan; Steinseifer, Ulrich

    2017-03-01

    Bioprosthetic aortic heart valves are increasingly implanted in younger patients. Therefore, a strategy for potential valve failure should be developed before implanting the 'first valve'. The goal of this in vitro study was to provide insight into the effects of the design of a bioprosthesis on a valve-in-valve implanted Sapien XT valve. The hydrodynamic performance of a 23-mm Sapien XT valve implanted in Vascutek Aspire, Edwards Perimount, Medtronic Mosaic and St. Jude Medical Trifecta heart valves was investigated in a left heart simulator. In addition to the hydrodynamic results, the leaflet dynamics were analysed in high-speed video recordings of the tests. All valve-in-valve combinations in this study fulfilled the minimum acceptance criteria defined by relevant approval standards (e.g. ISO 5840) but displayed significant differences in their performances. Small inner diameters of the bioprostheses were associated with increased mean pressure gradients, decreased effective orifice areas and geometric opening areas as well as with pin-wheeling and uneven leaflet motion. In addition, implantation in bioprostheses with internally mounted leaflets was associated with lower paravalvular leakage. The results of this study suggest that a surgical bioprosthesis with a large inner diameter and internally mounted leaflets improves the heamodynamics and potentially the durability of a valve-in-valve combination. These results should give the attending physicians critical information to consider when deciding on a bioprosthesis for younger patients.

  9. Stentless aortic valve replacement: an update

    Directory of Open Access Journals (Sweden)

    Kobayashi J

    2011-06-01

    area, mean pressure gradient, LV mass regression, surgical risk, durability, and late outcomes in stentless bioprostheses. There is no general recommendation to prefer stentless bioprostheses in all patients. For new-generation pericardial stentless valves, follow-up over 15 years is necessary to compare the excellent results of stented valves such as the Carpentier–Edwards Perimount and Hancock II valves.Keywords: cardiopulmonary bypass, valves, heart disease, surgery, follow-up studies 

  10. Cellular regulation of the structure and function of aortic valves

    Directory of Open Access Journals (Sweden)

    Ismail El-Hamamsy

    2010-01-01

    Full Text Available The aortic valve was long considered a passive structure that opens and closes in response to changes in transvalvular pressure. Recent evidence suggests that the aortic valve performs highly sophisticated functions as a result of its unique microscopic structure. These functions allow it to adapt to its hemodynamic and mechanical environment. Understanding the cellular and molecular mechanisms involved in normal valve physiology is essential to elucidate the mechanisms behind valve disease. We here review the structure and developmental biology of aortic valves; we examine the role of its cellular parts in regulating its function and describe potential pathophysiological and clinical implications.

  11. Study on the characters of control valve for ammonia injection in selective catalytic reduction (SCR) system of coal-fired power plant

    Science.gov (United States)

    Yao, Che; Li, Tao; Zhang, Hong; Zhou, Yanming

    2017-08-01

    In this paper, the characters of two control valves used for ammonia injection in SCR system are discussed. The linear/quadratic character between pressure drop/outlet flow rate and valve opening/dynamic pressure inlet are investigated using computational fluid dynamic (CFD) and response surface analysis (RSA) methods. The results show that the linear character of brake valve is significantly better than butterfly valve, which means that the brake valve is more suitable for ammonia injection adjustment than the butterfly valve.

  12. Noise generated by flow through large butterfly valves

    Science.gov (United States)

    Huff, Ronald G.

    1987-01-01

    A large butterfly valve (1.37 m diam) was acoustically tested to measure the noise generated and propagating in both the upstream and downstream directions. The experimental investigation used wall mounted pressure transducers to measure the fluctuating component of the pipe static pressure upstream and downstream of the valve. Microphones upstream of the pipe inlet and located in a plenum were used to measure the noise radiated from the valve in the upstream direction. Comparison of the wall pressure downstream of the valve to a prediction were made. Reasonable agreement was obtained with the valve operating at a choked condition. The noise upstream of the valve is 30 dB less than that measured downstream.

  13. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Science.gov (United States)

    Zhang, Ben; Chen, Xiang; Xu, Tong-yi; Zhang, Zhi-gang; Li, Xin; Han, Lin; Xu, Zhi-yun

    2014-01-01

    Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach. We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE) coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve), weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically. Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically. This design of the

  14. Oil pipeline valve automation for spill reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mohitpour, Mo; Trefanenko, Bill [Enbridge Technology Inc, Calgary (Canada); Tolmasquim, Sueli Tiomno; Kossatz, Helmut [TRANSPETRO - PETROBRAS Transporte S.A., Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Liquid pipeline codes generally stipulate placement of block valves along liquid transmission pipelines such as on each side of major river crossings where environmental hazards could cause or are foreseen to potentially cause serious consequences. Codes, however, do not stipulate any requirement for block valve spacing for low vapour pressure petroleum transportation, nor for remote pipeline valve operations to reduce spills. A review of pipeline codes for valve requirement and spill limitation in high consequence areas is thus presented along with a criteria for an acceptable spill volume that could be caused by pipeline leak/full rupture. A technique for deciding economically and technically effective pipeline block valve automation for remote operation to reduce oil spilled and control of hazards is also provided. In this review, industry practice is highlighted and application of the criteria for maximum permissible oil spill and the technique for deciding valve automation thus developed, as applied to ORSUB pipeline is presented. ORSUB is one of the three initially selected pipelines that have been studied. These pipelines represent about 14% of the total length of petroleum transmission lines operated by PETROBRAS Transporte S.A. (TRANSPETRO) in Brazil. Based on the implementation of valve motorization on these three pipeline, motorization of block valves for remote operation on the remaining pipelines is intended, depending on the success of these implementations, on historical records of failure and appropriate ranking. (author)

  15. Computed Flow Through An Artificial Heart Valve

    Science.gov (United States)

    Rogers, Stewart E.; Kwak, Dochan; Kiris, Cetin; Chang, I-Dee

    1994-01-01

    Report discusses computations of blood flow through prosthetic tilting disk valve. Computational procedure developed in simulation used to design better artificial hearts and valves by reducing or eliminating following adverse flow characteristics: large pressure losses, which prevent hearts from working efficiently; separated and secondary flows, which causes clotting; and high turbulent shear stresses, which damages red blood cells. Report reiterates and expands upon part of NASA technical memorandum "Computed Flow Through an Artificial Heart and Valve" (ARC-12983). Also based partly on research described in "Numerical Simulation of Flow Through an Artificial Heart" (ARC-12478).

  16. Numerical simulation of mitral valve function

    OpenAIRE

    Lau, K. D.

    2012-01-01

    In the mammalian heart there are four heart valves (HV), of which the largest is the mitral valve (MV). Key components in the circulatory system, correct HV function is vital to cardiovascular health. A tethered and asymmetric structure, the MV regulates unidirectional flow between the left atrium and left ventricle. MVfunction is divided between systole/closure, where theMVis required to sustain a pressure load ~120 mmHg whilst minimising flow reversal, and diastole/opening in wh...

  17. Risks for Heart Valve Problems

    Science.gov (United States)

    ... Thromboembolism Aortic Aneurysm More Risks for Heart Valve Problems Updated:Jan 18,2017 Who is at risk ... content was last reviewed May 2016. Heart Valve Problems and Disease • Home • About Heart Valves • Heart Valve ...

  18. Living with Heart Valve Disease

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  19. What Causes Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  20. Calculation of Mitral Valve Area in Mitral Stenosis: Comparison of Continuity Equation and Pressure Half Time With Two-Dimensional Planimetry in Patients With and Without Associated Aortic or Mitral Regurgitation or Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Roya Sattarzadeh

    2018-01-01

    Full Text Available Accurate measurement of Mitral Valve Area (MVA is essential to determining the Mitral Stenosis (MS severity and to achieving the best management strategies for this disease. The goal of the present study is to compare mitral valve area (MVA measurement by Continuity Equation (CE and Pressure Half-Time (PHT methods with that of 2D-Planimetry (PL in patients with moderate to severe mitral stenosis (MS. This comparison also was performed in subgroups of patients with significant Aortic Insufficiency (AI, Mitral Regurgitation (MR and Atrial Fibrillation (AF. We studied 70 patients with moderate to severe MS who were referred to echocardiography clinic. MVA was determined by PL, CE and PHT methods. The agreement and correlations between MVA’s obtained from various methods were determined by kappa index, Bland-Altman analysis, and linear regression analysis. The mean values for MVA calculated by CE was 0.81 cm (±0.27 and showed good correlation with those calculated by PL (0.95 cm, ±0.26 in whole population (r=0.771, P<0.001 and MR subgroup (r=0.763, P<0.001 and normal sinus rhythm and normal valve subgroups (r=0.858, P<0.001 and r=0.867, P<0.001, respectively. But CE methods didn’t show any correlation in AF and AI subgroups. MVA measured by PHT had a good correlation with that measured by PL in whole population (r=0.770, P<0.001 and also in NSR (r=0.814, P<0.001 and normal valve subgroup (r=0.781, P<0.001. Subgroup with significant AI and those with significant MR showed moderate correlation (r=0.625, P=0.017 and r=0.595, P=0.041, respectively. Bland Altman Analysis showed that CE would estimate MVA smaller in comparison with PL in the whole population and all subgroups and PHT would estimate MVA larger in comparison with PL in the whole population and all subgroups. The mean bias for CE and PHT are 0.14 cm and -0.06 cm respectively. In patients with moderate to severe mitral stenosis, in the absence of concomitant AF, AI or MR, the accuracy

  1. Europa Propulsion Valve Seat Material Testing

    Science.gov (United States)

    Addona, Brad M.

    2017-01-01

    The Europa mission and spacecraft design presented unique challenges for selection of valve seat materials that met the fluid compatibility requirements, and combined fluid compatibility and high radiation exposure level requirements. The Europa spacecraft pressurization system valves will be exposed to fully saturated propellant vapor for the duration of the mission. The effects of Nitrogen Tetroxide (NTO) and Monomethylhydrazine (MMH) propellant vapors on heritage valve seat materials, such as Vespel SP-1 and Polychlorotrifluoroethylene (PCTFE), were evaluated to determine if an alternate material is required. In liquid system applications, Teflon is the only available compatible valve seat material. Radiation exposure data for Teflon in an air or vacuum environment has been previously documented. Radiation exposure data for Teflon in an oxidizer environment such as NTO, was not available, and it was unknown whether the effects would be similar to those on air-exposed samples. Material testing was conducted by Marshall Space Flight Center (MSFC) and White Sands Test Facility (WSTF) to determine the effects of propellant vapor on heritage seat materials for pressurization valve applications, and the effects of combined radiation and NTO propellant exposure on Teflon. The results indicated that changes in heritage pressurization valve seat materials' properties rendered them unsuitable for the Europa application. The combined radiation and NTO exposure testing of Teflon produced results equivalent to combined radiation and air exposure results.

  2. Reasoning about Java's Reentrant Locks

    NARCIS (Netherlands)

    Haack, C.; Huisman, Marieke; Hurlin, C.; Ramalingam, G.

    2008-01-01

    This paper presents a verification technique for a concurrent Java-like language with reentrant locks. The verification technique is based on permission-accounting separation logic. As usual, each lock is associated with a resource invariant, i.e. when acquiring the lock the resources are obtained

  3. A Quantitative Study of Simulated Bicuspid Aortic Valves

    Science.gov (United States)

    Szeto, Kai; Nguyen, Tran; Rodriguez, Javier; Pastuszko, Peter; Nigam, Vishal; Lasheras, Juan

    2010-11-01

    Previous studies have shown that congentially bicuspid aortic valves develop degenerative diseases earlier than the standard trileaflet, but the causes are not well understood. It has been hypothesized that the asymmetrical flow patterns and turbulence found in the bileaflet valves together with abnormally high levels of strain may result in an early thickening and eventually calcification and stenosis. Central to this hypothesis is the need for a precise quantification of the differences in the strain rate levels between bileaflets and trileaflet valves. We present here some in-vitro dynamic measurements of the spatial variation of the strain rate in pig aortic vales conducted in a left ventricular heart flow simulator device. We measure the strain rate of each leaflet during the whole cardiac cycle using phase-locked stereoscopic three-dimensional image surface reconstruction techniques. The bicuspid case is simulated by surgically stitching two of the leaflets in a normal valve.

  4. Hydraulic Structures : Locks

    NARCIS (Netherlands)

    Molenaar, W.F.

    These lecture notes on locks are part of the study material belonging to the course 'Hydraulic Structures 1' (code CT3330), part of the Bachelor of Science and the Master of Science, the Hydraulic Engineering track, for civil engineering students at Delft University of Technology. Many of the

  5. Roller Locking Brake

    Science.gov (United States)

    Vranish, John M.

    1993-01-01

    Roller locking brake is normally braking rotary mechanism allowing free rotation when electromagnet in mechanism energized. Well suited to robots and other machinery which automatic braking upon removal of electrical power required. More compact and reliable. Requires little electrical power to maintain free rotation and exhibits minimal buildup of heat.

  6. Locked nucleic acid

    DEFF Research Database (Denmark)

    Jepsen, Jan Stenvang; Sørensen, Mads D; Wengel, Jesper

    2004-01-01

    Locked nucleic acid (LNA) is a class of nucleic acid analogs possessing very high affinity and excellent specificity toward complementary DNA and RNA, and LNA oligonucleotides have been applied as antisense molecules both in vitro and in vivo. In this review, we briefly describe the basic physioc...

  7. Locks and Keys Service

    CERN Multimedia

    Claude Ducastel

    The GS-LS-SEM section is pleased to inform you that as from Monday 30 November 2009, the opening hours of the Locks and Keys service will be the following: 08h30 - 12h30 / 13h30 - 16:30, Mondays to Fridays. GS-SEM-LS 73333

  8. Mitral valve prolapse

    Science.gov (United States)

    ... mitral valve prolapse is called "mitral valve prolapse syndrome," and includes: Chest pain (not caused by coronary artery disease or a heart attack) Dizziness Fatigue Panic attacks Sensation of feeling the heart beat ( palpitations ) ...

  9. Mitral Valve Stenosis

    Science.gov (United States)

    ... valve stenosis include: Rheumatic fever. A complication of strep throat, rheumatic fever can damage the mitral valve. Rheumatic ... children see your doctor for sore throats. Untreated strep throat infections can develop into rheumatic fever. Fortunately, strep ...

  10. Characteristic Analysis and Experiment of a Dynamic Flow Balance Valve

    Science.gov (United States)

    Bin, Li; Song, Guo; Xuyao, Mao; Chao, Wu; Deman, Zhang; Jin, Shang; Yinshui, Liu

    2017-12-01

    Comprehensive characteristics of a dynamic flow balance valve of water system were analysed. The flow balance valve can change the drag efficient automatically according to the condition of system, and the effective control flowrate is constant in the range of job pressure. The structure of the flow balance valve was introduced, and the theoretical calculation formula for the variable opening of the valve core was derived. A rated pressure of 20kPa to 200kPa and a rated flowrate of 10m3/h were offered in the numerical work. Static and fluent CFX analyses show good behaviours: through the valve core structure optimization and improve design of the compressive spring, the dynamic flow balance valve can stabilize the flowrate of system evidently. And experiments show that the flow control accuracy is within 5%.

  11. Isolated Pulmonary Valve Endocarditis

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Hatamizadeh

    2009-06-01

    Full Text Available Infective endocarditis is one of the most severe complications of parenteral drug abuse. The outstanding clinical feature of infective endocarditis in intravenous drug abusers is the high incidence of right-sided valve infection, and the tricuspid valve is involved in 60% to 70% of the cases. We herein report a case of isolated pulmonic valve infective endocarditis with a native pulmonary valve.

  12. A case of SAPIEN XT valve fallen into left ventricle during valve-in-valve transcatheter aortic valve implantation.

    Science.gov (United States)

    Koizumi, Shigeki; Ehara, Natsuhiko; Nishiya, Kenta; Koyama, Tadaaki

    2017-06-24

    Late transcatheter heart valve embolization is a rare but life-threatening complication of transcatheter aortic valve implantation. Surgical intervention is performed for most cases, but some cases were treated by valve-in-valve transcatheter aortic valve implantation. We describe a patient in whom a 29-mm Edwards SAPIEN XT valve migrated into the left ventricular outflow tract 41 days after the initial implantation. We tried to perform valve-in-valve transcatheter aortic valve implantation using a transfemoral approach. As soon as the second transcatheter heart valve touched the first implanted valve, it fell into the left ventricle. Immediate surgical intervention was required. The first valve was removed, and surgical aortic valve replacement was successfully performed. In conclusion, we should choose surgical aortic valve replacement for late transcatheter heart valve embolization. Even if we need to treat by catheter intervention, transapical approach may be better.

  13. Airbag vent valve and system

    Science.gov (United States)

    Peterson, Leslie D. (Inventor); Zimmermann, Richard E. (Inventor)

    2001-01-01

    An energy absorbing airbag system includes one or more vent valve assemblies for controlling the release of airbag inflation gases to maintain inflation gas pressure within an airbag at a substantially constant pressure during a ride-down of an energy absorbing event. Each vent valve assembly includes a cantilever spring that is flat in an unstressed condition and that has a free end portion. The cantilever spring is secured to an exterior surface of the airbag housing and flexed to cause the second free end portion of the cantilever spring to be pressed, with a preset force, against a vent port or a closure covering the vent port to seal the vent port until inflation gas pressure within the airbag reaches a preselected value determined by the preset force whereupon the free end portion of the cantilever spring is lifted from the vent port by the inflation gases within the airbag to vent the inflation gases from within the airbag. The resilience of the cantilever spring maintains a substantially constant pressure within the airbag during a ride-down portion of an energy absorbing event by causing the cantilever spring to vent gases through the vent port whenever the pressure of the inflation gases reaches the preselected value and by causing the cantilever spring to close the vent port whenever the pressure of the inflation gases falls below the preselected value.

  14. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  15. Unsteady Analyses of a Control Valve due to Fluid-Structure Coupling

    Directory of Open Access Journals (Sweden)

    Yudong Xie

    2013-01-01

    Full Text Available Control valves play important roles in the control of the mixed-gas pressure in the combined cycle power plants (CCPP. In order to clarify the influence of coupling between the structure and the fluid system at the control valve, the coupling mechanism was presented, and the numerical investigations were carried out. At the same operating condition in which the pressure oscillation amplitude is greater when considering the coupling, the low-order natural frequencies of the plug assembly of the valve decrease obviously when considering the fluid-structure coupling action. The low-order natural frequencies at 25% valve opening, 50% valve opening, and 75% valve opening are reduced by 11.1%, 7.0%, and 3.8%, respectively. The results help understand the processes that occur in the valve flow path leading to the pressure control instability observed in the control valve in the CCPP.

  16. Design of Bidirectional Check Valve for Discrete Fluid Power Force System for Wave Energy Converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2014-01-01

    introduces large switching losses, especially when large pressure difference is present across the valves in the manifold. The current paper therefore focus on designing a bidirectional check valve for use in the switching manifold of the discrete force systems. The use of the bidirectional check valve...... enables passive force switching under minimal pressure difference, hence minimal energy loss. The bidirectional check valve is designed with a rated flow in the range of 1000L/min@5bar. The flow direction of the bidirectional check valve is set by the setting the pilot pressure. This paper presents...... a functionality test of a 125 L/min@5bar bidirectional check, leading to the design and modelling of a bidirectional check valve for ocean wave energy. It shows that a feasible bidirectional check valve may be configured by employing a multi-poppet topology for the main stage and utilising a 3/2 switching valve...

  17. Structures of Bordered Pits Potentially Contributing to Isolation of a Refilled Vessel from Negative Xylem Pressure in Stems of Morus australis Poir.: Testing of the Pit Membrane Osmosis and Pit Valve Hypotheses.

    Science.gov (United States)

    Ooeda, Hiroki; Terashima, Ichiro; Taneda, Haruhiko

    2017-02-01

    Two hypotheses have been proposed to explain the mechanism preventing the refilling vessel water from being drained to the neighboring functional vessels under negative pressure. The pit membrane osmosis hypothesis proposes that the xylem parenchyma cells release polysaccharides that are impermeable to the intervessel pit membranes into the refilling vessel; this osmotically counteracts the negative pressure, thereby allowing the vessel to refill. The pit valve hypothesis proposes that gas trapped within intervessel bordered pits isolates the refilling vessel water from the surrounding functional vessels. Here, using the single-vessel method, we assessed these hypotheses in shoots of mulberry (Morus australis Poir.). First, we confirmed the occurrence of xylem refilling under negative pressure in the potted mulberry saplings. To examine the pit membrane osmosis hypothesis, we estimated the semi-permeability of pit membranes for molecules of various sizes and found that the pit membranes were not semi-permeable to polyethylene glycol of molecular mass osmosis mechanism in mulberry would be unrealistically large. © The Author 2016. Published by Oxford University Press on behalf of Japanese Society of Plant Physiologists. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  18. Pressure activated stability-bypass-control valves to increase the stable airflow range of a Mach 2.5 inlet with 40 percent internal contraction

    Science.gov (United States)

    Mitchell, G. A.; Sanders, B. W.

    1974-01-01

    The throat of a Mach 2.5 inlet with a coldpipe termination was fitted with a stability-bypass system. The inlet stable airflow range provided by various stability-bypass entrance configurations in alternate combination with several stability-bypass exit controls was determined for both steady-state conditions and internal transient pulses. Transient results were also obtained for the inlet with a choke point at the diffuser exit. Instart angles of attack were determined for the various stability-bypass entrance configurations. The response of the inlet-coldpipe system to internal and external oscillating disturbances was determined. Poppet valves at the stability-bypass exit provided an inlet stable airflow range of 28 percent or greater at all static and transient conditions.

  19. Innovation and Lock-in

    DEFF Research Database (Denmark)

    Cantner, Uwe; Vannuccini, Simone

    2016-01-01

    This study focuses on a well-known but yet elusive concept: (technological) lock-in. We summarize what is known about the nature of lock-in and offer a critical view on history-dependent processes based on recent contributions to the literature. We discuss if lock-ins are really inescapable......, especially when innovation is concerned. Also, we address the question if lock-in is a well-defined concept at all. To offer a fresh view on lock-in and to tackle the issues just raised, we employ the replicator dynamics model. By making a parallel between monopolization in the replicator dynamics...... and the occurrence of lock-ins, we show that the convergence of a system to a given outcome can be reversed, under certain conditions. We highlight the need for a more precise demarcation of the conceptual boundaries of lock-in and path dependence, both from the formal and the empirical side, and suggest...

  20. 40 CFR 60.482-8a - Standards: Pumps, valves, and connectors in heavy liquid service and pressure relief devices in...

    Science.gov (United States)

    2010-07-01

    ... Equipment Leaks of VOC in the Synthetic Organic Chemicals Manufacturing Industry for Which Construction... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. 60... connectors in heavy liquid service and pressure relief devices in light liquid or heavy liquid service. (a...

  1. Fluid-solid modeling of lymphatic valves

    Science.gov (United States)

    Caulk, Alexander; Ballard, Matthew; Nepiyushchikh, Zhanna; Dixon, Brandon; Alexeev, Alexander

    2015-11-01

    The lymphatic system performs important physiological functions such as the return of interstitial fluid to the bloodstream to maintain tissue fluid balance, as well as the transport of immune cells in the body. It utilizes contractile lymphatic vessels, which contain valves that open and close to allow flow in only one direction, to directionally pump lymph against a pressure gradient. We develop a fluid-solid model of geometrically representative lymphatic valves. Our model uses a hybrid lattice-Boltzmann lattice spring method to capture fluid-solid interactions with two-way coupling between a viscous fluid and lymphatic valves in a lymphatic vessel. We use this model to investigate the opening and closing of lymphatic valves, and its effect on lymphatic pumping. This helps to broaden our understanding of the fluid dynamics of the lymphatic system.

  2. Automatic balancing valves in distribution networks today

    Energy Technology Data Exchange (ETDEWEB)

    Golestan, F. [Flow Design, Inc., Dallas, TX (United States)

    1996-12-31

    Automatic flow-limiting (self-actuated) valves have been in the heating, ventilating, and air-conditioning (HVAC) market for some time now. Their principle of operation is based on fluid momentum and Bernoulli`s theorem. Basically, they absorb pressure to keep the flow rate constant. The general operation and their flow characteristics are described in the 1992 ASHRAE Handbook--Systems and Equipment, chapter 43 (ASHRAE 1992). The application and interaction of these valves with other system components, when installed in hydronic distribution networks, are outlined in this presentation. A simple, multilevel piping network is analyzed. The network consists of a pump, connecting piping, an automatic temperature control valve (ATC), a coil, and balancing valves.

  3. Frostless heat pump having thermal expansion valves

    Science.gov (United States)

    Chen, Fang C [Knoxville, TN; Mei, Viung C [Oak Ridge, TN

    2002-10-22

    A heat pump system having an operable relationship for transferring heat between an exterior atmosphere and an interior atmosphere via a fluid refrigerant and further having a compressor, an interior heat exchanger, an exterior heat exchanger, a heat pump reversing valve, an accumulator, a thermal expansion valve having a remote sensing bulb disposed in heat transferable contact with the refrigerant piping section between said accumulator and said reversing valve, an outdoor temperature sensor, and a first means for heating said remote sensing bulb in response to said outdoor temperature sensor thereby opening said thermal expansion valve to raise suction pressure in order to mitigate defrosting of said exterior heat exchanger wherein said heat pump continues to operate in a heating mode.

  4. Avoiding lock-in

    DEFF Research Database (Denmark)

    Henriksen, Ingrid

    1999-01-01

    The paper investigates the initial phase of the cooperative organisation of agricultural processing firms in Denmark. It argues that the variations observed can be explained within the framework of the theory of industrial organisation. The focus is on the success of cooperative creameries. In 19...... of gathering information and of preserving and transporting a perishable product, were ideally suited to overcome the problems of potential lock-in and of asymmetric information...

  5. Data port security lock

    Science.gov (United States)

    Quinby, Joseph D [Albuquerque, NM; Hall, Clarence S [Albuquerque, NM

    2008-06-24

    In a security apparatus for securing an electrical connector, a plug may be fitted for insertion into a connector receptacle compliant with a connector standard. The plug has at least one aperture adapted to engage at least one latch in the connector receptacle. An engagement member is adapted to partially extend through at least one aperture and lock to at least one structure within the connector receptacle.

  6. Valve exploiting the principle of a side channel turbine

    Science.gov (United States)

    Jandourek, Pavel; Pochylý, František; Haban, Vladimír

    2017-04-01

    The presented article deals with a side channel turbine, which can be used as a suitable substitute for a pressure reducing valve. Pressure reducing valves are a source of high hydraulic losses. The aim is to replace them by a side channel turbine. With that in mind, hydraulic losses can be replaced by a production of electrical energy at comparable characteristics of the reducing valve and the side channel turbine. The basis for the design is the loss characteristics of the pressure reducing valve. Thereby create a new kind of turbine valve with speed-controlled flow in dependence of the runner revolution. It is technical innovation and new renewable source of energy, which can be in future used in rehabilitation or projecting of pumped-storage power plants. It also increases the power of the power plant.

  7. Oil Stiction in Fast Switching Annular Seat Valves for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    Digital Displacement (DD) fluid power machines utilizes electronically controlled seat valves connected to pressure chambers to obtain variable displacement with high operational efficiency and high bandwidth. To achieve high efficiency, fast valve switching is essential and all aspects related...... to the dynamic behaviour of the seat valves must be considered to optimize the machine efficiency. A significant effect influencing the valves switching performance is the presence of oil stiction when separating the contact surfaces in valve opening movement. This oil stiction force is limited by cavitation...... for low pressure levels, e.g. valves connected to the low pressure manifold, however for valves operated at higher pressure levels, the oil stiction force is dominating when the separating surfaces are close to contact. This paper presents an analytic solution to the oil stiction force for annular seat...

  8. 46 CFR 56.20-15 - Valves employing resilient material.

    Science.gov (United States)

    2010-10-01

    ... 5 percent of its fully open flow rate or 15 percent divided by the square root of the nominal pipe... shutoff valve is required. (c) If a valve designer elects to use either a calculation or actual fire testing instead of material removal and pressure testing, the calculation must employ ISA-S75.02...

  9. Operational durability of a giant ER valve for Braille display

    Science.gov (United States)

    Luning, Xu; Han, Li; Yufei, Li; Shen, Rong; Kunquan, Lu

    2017-05-01

    The compact configuration of giant ER (electrorheological) valves provides the possibility of realizing a full-page Braille display. The operational durability of ER valves is a key issue in fulfilling a Braille display. A giant ER valve was used to investigate the variations in pressure drops and critical pressure drops of the valves over a long period under some typical operational parameters. The results indicate that neither the pressure drops nor critical pressure drops of giant ER valves show apparent deterioration over a long period. Without ER fluid exchange, a blockage appears in the channel of the valve because the ER structures induced by an external electric field cannot be broken by the Brownian motion of hydraulic oil molecules when the external electric field is removed. Forcing ER fluid flow is an effective and necessary method to keep the channel of the valve unblocked. Thus the operational durability of the valve using giant ER fluids is able to meet the demands of Braille display.

  10. Quick-closing valve is actuated by explosive discharge

    Science.gov (United States)

    Majeski, S. J.

    1966-01-01

    Remotely controlled plug-type valve shuts off a high-pressure, high-temperature gas flow in a few milliseconds. The valve is actuated by a commercially available electrically initiated squib of low explosive power. More rapid closure is attainable with squibs containing heavier explosive changes.

  11. Design Optimisation and Conrol of a Pilot Operated Seat Valve

    DEFF Research Database (Denmark)

    Nielsen, Brian; Andersen, Torben Ole; Hansen, Michael Rygaard

    2004-01-01

    The paper gives an approach for optimisation of the bandwidth of a pilot operated seat valve for mobile applications. Physical dimensions as well as parameters of the implemented control loop are optimised simultaneously. The frequency response of the valve varies as a function of the pressure drop...

  12. Exchange of information concerning leaky valves on paste pumps

    Energy Technology Data Exchange (ETDEWEB)

    Pier, M.

    1943-01-01

    This series of correspondence concerns an exchange of experience following trouble in a Gelsenberg coal stall arising from leaking valves on a paste pump. At Gelsenberg, each nine adjacent paste presses worked for two chambers with a common collector main line, the two divisions of which went to the two chambers with a common collector main line, the two divisions of which went to the two chambers. Normally, a pump was kept in reserve and each pump had two hand-operated shut-off valves on the pressure side. There were check valves on the collector line. In the accident at Gelsenberg, a pressure valve on one of the operating pumps sprang a leak. The temperature in the preheater stall suddenly rose, the preheater was extinguished, and the temperature was quickly lowered with cold gas. The temperature rise occurred because the suction valve as well as the defective pump was cut through so that the remaining three pumps forced the coal paste through the one pump back into the pasting oil tank. The leak was so strong that converter pressure dropped; no paste was reaching the converter. The check valve at the converter inlet remained tight enough so that the converter contents were not discharged backwards before the shutoff valves of the leaky pump were turned off. Variation of situations precluded much generalization of experiences, but replies from other plants had indicated that no instance of stall damage had arisen from leaky valves. These had always been discovered in time to prevent damage. When irregularities were discovered in the valves, the paste pumps were to be shut down on the pressure side before flushing. Regular inspection of converter check valves was recommended. Location of check valves behind the presses was advised against, although plant conditions made this advisory nondefinitive. 3 figures.

  13. Design Method for Fast Switching Seat Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    method for DD seat valves are presented, taking into account the significant aspects related to obtaining efficient DD valves with basis in a given DD machine specifications. The seat area is minimized and the stroke length is minimized to obtain fast switching times while considering the pressure loss...... of the valves. A coupled optimization is finally conducted to optimize the electro-magnetic actuator, leading to a valve design based on the chosen valve topology. The design method is applied to an example DD machine and the resulting valve design fulfilling the requirements is presented....

  14. Modeling of movement-induced and flow-induced fluid forces in fast switching valves

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Schmidt, Lasse

    2015-01-01

    Fast switching fluid power valves set strict requirements on performance, size and energy efficiency and simulation models are therefore needed to obtain good designs of such components. The valve moving member is subject to fluid forces depending on the valve flow rate and movement of the valve......-pressure relationship of a switching valve based on CFD results is presented along with the fluid force model, to constitute a complete valve fluid model. The parameters needed for the proposed model are determined based on CFD analyses, and the process of finding these parameters are described based on a reference...

  15. Study of safety relief valve operation under ATWS conditions. [PWR

    Energy Technology Data Exchange (ETDEWEB)

    Hutmacher, E.S.; Nesmith, B.J.; Brukiewa, J.B.

    1979-06-25

    A literature survey and analysis project has been performed to determine if recent (since mid-1975) data has been reported which could influence the current approach to predicting PWR relief valve capacity under ATWS conditions. This study was conducted by the Energy Technology Engineering Center for NRC. Results indicate that the current relief valve capacity model tends to predict less capacity than actually obtains; however, no experimental verification at PWR ATWS conditions was found. Other project objectives were to establish the availability of methods for evaluating reaction forces and back pressure effects on relief valve capacity, and to determine if facilities exist which are capable of testing PWR relief valves at ATWS conditions.

  16. Note: An improved solenoid driver valve for miniature shock tubes.

    Science.gov (United States)

    Lynch, P T

    2016-05-01

    A solenoid driver valve has been built to improve the operating performance of diaphragmless shock tubes, which are used for high pressure, high temperature chemical kinetics, and fluid mechanics studies. For shock tube driver application, the most important characteristics are those of sealing, strength, and quality of the generated shock waves and repeatability of opening characteristics and therefore subsequent post-shock conditions. The main features of the new driver valve are a face o-ring sealing design of the valve, the large internal volume, and through inserts near the solenoid core: adjustable opening characteristics of the valve.

  17. 49 CFR 236.338 - Mechanical locking required in accordance with locking sheet and dog chart.

    Science.gov (United States)

    2010-10-01

    ... locking sheet and dog chart. 236.338 Section 236.338 Transportation Other Regulations Relating to... in accordance with locking sheet and dog chart. Mechanical locking shall be in accordance with locking sheet and dog chart currently in effect. ...

  18. The dilemma of complicated shunt valves: How to identify patients with posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage who will benefit from a simple valve?

    Directory of Open Access Journals (Sweden)

    Christian von der Brelie

    2016-01-01

    Full Text Available Background: Sophisticated shunt valves provide the possibility of pressure adjustment and antisiphon control but have a higher probability of valve dysfunction especially in a posthemorrhagic setting. The aim of the present study is to analyze the clinical outcome of patients with shunt dependent posthemorrhagic hydrocephalus after aneurysmatic subarachnoid hemorrhage (SAH in order to identify patients who would benefit from a simple differential pressure valve. Methods: From 2000 to 2013, 547 patients with aneurysmatic SAH were treated at our institution, 114 underwent ventricular shunt placement (21.1%. 47 patients with available pre- and post-operative computed tomography scans, and an available follow-up of minimum 6 months were included. In order to measure the survival time which a nonprogrammable differential pressure valve would have had in an individual patient we defined the initial equalized shunt survival time (IESS. IESS is the time until surgical revisions of fixed differential pressure or flow-regulated valves for the treatment of over- or under-drainage as well as re-programming of adjustable valves due to over- or under-drainage. Results: Twenty patients were treated with fixed differential pressure valves, 15 patients were treated with flow-regulated valves, and 12 underwent ventriculoperitoneal (VP shunt placement with differential pressure valves assisted by a gravitational unit. Patients who reacted with remarkable changes of the ventricular width after the insertion of external ventricular drainage (EVD, before shunt placement, showed a significantly longer IESS. Conclusions: Decline of the ventricular width after EVD placement was a predictor for successful VP shunt therapy in the later course of disease. Possibly, this could allow identifying patients who benefit from a simple differential pressure valve or a flow-regulated valve, and thus could possibly avoid valve-associated complications of a programmable valve in the

  19. Curvas de desempenho de válvulas reguladoras de pressão novas e com diferentes tempos de utilização Performance curves of new and used pressure regulating valves

    Directory of Open Access Journals (Sweden)

    Sílvio C. R. V. Lima

    2003-08-01

    Full Text Available O desempenho de uma válvula reguladora de pressão, fabricada pela Fabrimar, Modelo Exact-20-Ref. RP-3-20-3/4"FF, utilizada em pivô central, foi avaliado em laboratório, conforme as normas ISO (1993. Este trabalho foi desenvolvido no Laboratório de Irrigação do Departamento de Engenharia Rural, ESALQ/USP, utilizando-se reguladores de pressão novos e com diferentes tempos de emprego no campo. As curvas de desempenho das válvulas novas satisfizeram as condições exigidas pela norma, caracterizando o regulador como do tipo A, para as velocidades de referência de 0,5 m s-1 (vazão de 0,57 m³ h-1 até 4,0 m s-1 (vazão de 4,50 m³ h-1 e várias pressões de entrada, sendo também elaborado um modelo estatístico para a pressão de saída do regulador novo, com uma vazão e uma pressão de entrada. Foram coletadas, de diversos sistemas tipo pivô central e de diferentes vãos, válvulas reguladoras de pressão do mesmo modelo, que possuíam tempos de uso de 2000, 2500, 6000, 8500, 9000 e 10000 h e, também, com diferentes qualidades de água utilizadas. Os ensaios seguiram os mesmos padrões dos novos, realizando-se uma análise estatística dos dados. Apesar dos desgastes provocados pela água de má qualidade e dos vazamentos apresentados, o desempenho hidráulico das válvulas com tempo de uso até 6000 h, não diferiu do desempenho das novas, para pressões de entrada até 826,3 kPa e velocidades de referência até 2,5 m s-1. O desempenho dos reguladores de pressão com tempos de uso iguais ou superiores a 8500 h, não se manteve semelhante ao do regulador novo, especialmente para pressões de entrada superiores a 481,7 kPa.The performance of a pressure regulator valve, manufactured by Fabrimar (Model Exact-20-Ref. RP-3-20-3/4"FF, for central pivot applications, was evaluated in the laboratory following the ISO 1993 norms. The tests were conducted in the Laboratory of Irrigation of the Department of Rural Engineering, ESALQ/USP. The

  20. Integrated nozzle - flapper valve with piezoelectric actuator and isothermal chamber: a feedback linearization multi control device

    Energy Technology Data Exchange (ETDEWEB)

    Kamali, Mohammadreza; Jazayeri, Seyed Ali [K. N.Toosi University of Technology, Tehran (Iran, Islamic Republic of); Najafi, Farid [University of Guilan, Rasht (Iran, Islamic Republic of); Kawashima, Kenji [Tokyo Medical and Dental University, Tokyo (Japan); Kagawa, Toshiharu [Tokyo Institute of Technology, Tokyo (Japan)

    2016-05-15

    This paper introduces a new nozzle-flapper valve with isothermal chamber using piezoelectric actuator. It controls the pressure and flow rate simply, effectively and separately. The proposed valve uses isothermal chamber presenting practical isothermal condition due to its large heat transfer interfaces filled by metal wool. The valve uses stacked type piezoelectric actuator with unique advantages. By using this valve, a simple method has been fulfilled to control flow rate or pressure of ideal gases in a pneumatic actuators. Experimental results demonstrated applications of the proposed valve to control either pressure or flow rate in pneumatic circuits. This valve can be also used in the pilot stage valve to actuate the main stage of a much bigger pneumatic valve. Designated structure contains only one pressure sensor installed on the isothermal control chamber, capable of controlling both pressure and flow rate. The desired output mass flow rate of the valve is controlled by the pressure changes during positioning of piezoelectric actuator at proper position. The proposed valve can control steady and unsteady oscillatory flow rate and pressure effectively, using nonlinear control method such as feedback linearization approach. Its effectiveness is demonstrated and validated through simulation and experiments.

  1. Lined 10'' butterfly valve outlasts competitive valves in brine filter system

    Energy Technology Data Exchange (ETDEWEB)

    Gaines, A.

    1982-03-01

    One of the world's largest chlorine production units located in the Gulf Coast area has an extensive brine piping system with a large number of valves. Some of the valves performed well but many failed to meet the service requirements, especially in the brine filtering system with the salt solution at ambient temperatures and pressures about 100 psi. One of these was a 10'' valve. Various types of gear-operated butterfly valves, with an elastomer lining to withstand the somewhat corrosive solution, had been tried but developed leaks and had to be repaired or replaced after 4 to 6 months. The valves became difficult or impossible to operate in some cases when brine leaking past the stem seal attacked the inner surface of the metal valve body and the liner was dislodged by the movement of the disc. In September 1980, a 10'' butterfly valve specifically designed for bubble-tight shut off and zero stem leakage was installed in the brine filter line on a trial basis. The valve has a 1-piece, epoxy-coated ductile iron body with a molded one-piece liner of Hypalon rubber, and a stainless steel stem and disc with splines instead of pins to provide a trouble-free connection. The stem is positively sealed against leakage by a patented spherical machining process on both the disc and the liner. The valve was furnished with a variable ratio gear actuator that has higher torque output when the disc begins to make contact with the seat to assure a bubble-tight shutoff with minimum input torque. The butterfly valve has provided leaktight performance since it was installed in September 1980 and is still easy to open and close by the geared actuator.

  2. Pressure Characteristic Analysis of a Hydraulic System

    Science.gov (United States)

    Cho, H. Y.; Yang, H. J.

    2017-02-01

    EPPR(ElectroProportional Pressure Reducing) valve control the MCV(Main Control Valve) built on the mobile heavy machine. The EPPR valve was tested in the experimental setup and the performance of the valve was compared with that of the existing EPPR valve. On thisstudy, electromagnetic properties analysis using AMESim program was performed to optimize the designing of EPPR Valve (Electric Proportional Pressure Reducing Valve) and by applying its results to the hydraulic system analytical model, performance of the valve could be predicted. Also by comparing the results of the actual experiment and the simulation, The results of thisstudy is that the 3 factor(cone angle, tip width, clearance between sleeve and plunger) have much effectiveness than other components in the EPPR valve.

  3. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  4. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  5. 49 CFR 236.330 - Locking dog of switch-and-lock movement.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking dog of switch-and-lock movement. 236.330 Section 236.330 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD... Rules and Instructions § 236.330 Locking dog of switch-and-lock movement. Locking dog of switch-and-lock...

  6. The Development of the Code Safety Valve Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Kim, Young Ae; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-07-01

    The Pressurizer Safety Valves (PSV) in Pressurized Water Reactors (PWRs) are required to provide the overpressure protection for the Reactor Coolant System (RCS) during the overpressure transients. According to the ASME OM code, all safety valves should be tested every 5 years with the acceptance tolerance of 1%. If one valve failed to meet this criterion, other two additional valves should be tested and if these valves don't meet the requirement, all valves should be tested. These frequent tests may make the valves decrepit and become a cause of leak. Therefore, increase of the acceptance tolerance is vital for the safe operation of the plant. In the United States, the acceptance tolerances are enlarged up to about 3% in most plants. This requires re-analysis of relevant accidents in FSAR. Also, the technical background data for the valve pop-up characteristics and the loop seal dynamics (if the plant has the loop seal in the upstream of PSV) are needed for the new safety analysis. Korea Hydro and Nuclear Power Company (KHNP) plans to build the PSV test facility for the purpose of providing the background data. This paper describes the preliminary design of the facility and studies on the system dynamics using GOTHIC-7.2a code to verify the pressure vessel capacities and to find the best operating condition.

  7. Electromechanically Actuated Valve for Controlling Flow Rate

    Science.gov (United States)

    Patterson, Paul

    2007-01-01

    . The inlet end (the right end as depicted in the figure) of the ball screw would be the main seating valve element: in the fully closed position, it would be pressed against the valve seat, as depicted in the upper part of the figure. A retainer would hold the valve seat in an inlet fitting. In addition, the retainer would be contoured to obtain a specified flow rate as a function of axial position of the ball screw. In the fully closed position, little force would be needed to press the ball screw against the seat because the push bore area upon which the upstream pressure would act would be small. The motor would position and hold the ball screw against the seat, providing the force necessary for sealing. To open the valve to a particular position, the motor would be commanded to rotate to a particular angular position (equivalently, a particular number of revolutions) at a particular rate of rotation within its torque limitations. Once the valve was open, fluid would flow through the inlet fitting and the chamber in the inlet housing, past the seat and its retainer, along the hollow core of the ball screw, and through the outlet housing and outlet fitting. The net force generated from fluid pressure in the open position would be small because the pressure exposed to the push bore areas at the inlet and outlet are nearly equal and the forces generated would be in opposing directions.

  8. Design Support and Analysis Tool for Pyrotechnically Actuated Valves Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Pyrotechnically actuated valves are triggered on or off by firing an explosive charge that rapidly releases large amounts of high-pressure, gas. Pyrovalves are...

  9. Technique to Improve Tracheostomy Speaking Valve Tolerance after Head and Neck Free Flap Reconstruction.

    Science.gov (United States)

    Stranix, John T; Danziger, Keri M; Dumbrava, Veturia L; Mars, Ginger; Hirsch, David L; Levine, Jamie P

    2016-12-01

    Increased upper airway resistance from postoperative changes after major head and neck surgery may cause elevated transtracheal pressures and result in tracheostomy speaking valve intolerance. This may be particularly true among patients with baseline pulmonary disease. We describe a patient recovering from oral cancer resection and flap reconstruction who demonstrated prolonged ventilator dependence and tracheostomy speaking valve intolerance with abnormal tracheal manometry. We attempted to improve speaking valve tolerance through the adaptation of a valve modification intended to reduce transtracheal pressures. Drilling holes into the 1-way speaking valve allowed for excess air egress and resulted in normalization of transtracheal pressures with improved speaking valve tolerance. This 1-way speaking valve modification may serve as a simple method to allow for earlier restoration of voicing and potentially reduce the number of ventilator- dependent days in this patient population.

  10. Mitral valve mechanics following posterior leaflet patch augmentation

    DEFF Research Database (Denmark)

    Rahmani, Azadeh; Rasmussen, Ann Qvist; Hønge, Jesper Langhoff

    2013-01-01

    Background and aim of the study: Attention towards the optimization of mitral valve repair methods is increasing. Patch augmentation is one strategy used to treat functional ischemic mitral regurgitation (FIMR). The study aim was to investigate the force balance changes in specific chordae...... tendineae emanating from the posterior papillary muscle in a FIMR-simulated valve, following posterior leaflet patch augmentation. Methods: Mitral valves were obtained from 12 pigs (body weight 80 kg). An in vitro test set-up simulating the left ventricle was used to hold the valves. The left ventricular...... pressure was regulated with water to simulate different static pressures during valve closure. A standardized oval pericardial patch (17 × 29 mm) was introduced into the posterior leaflet from mid P2 to the end of the P3 scallop. Dedicated miniature transducers were used to record the forces exerted...

  11. Modeling the Mitral Valve

    Science.gov (United States)

    Kaiser, Alexander

    2016-11-01

    The mitral valve is one of four valves in the human heart. The valve opens to allow oxygenated blood from the lungs to fill the left ventricle, and closes when the ventricle contracts to prevent backflow. The valve is composed of two fibrous leaflets which hang from a ring. These leaflets are supported like a parachute by a system of strings called chordae tendineae. In this talk, I will describe a new computational model of the mitral valve. To generate geometry, general information comes from classical anatomy texts and the author's dissection of porcine hearts. An MRI image of a human heart is used to locate the tips of the papillary muscles, which anchor the chordae tendineae, in relation to the mitral ring. The initial configurations of the valve leaflets and chordae tendineae are found by solving solving an equilibrium elasticity problem. The valve is then simulated in fluid (blood) using the immersed boundary method over multiple heart cycles in a model valve tester. We aim to identify features and mechanisms that influence or control valve function. Support from National Science Foundation, Graduate Research Fellowship Program, Grant DGE 1342536.

  12. Mechanisms of mechanical heart valve cavitation in an electrohydraulic total artificial heart.

    Science.gov (United States)

    Lee, Hwansung; Taenaka, Yoshiyuki; Kitamura, Soichiro

    2005-01-01

    Until now, we have estimated cavitation for mechanical heart valves (MHV) mounted in an electrohydraulic total artificial heart (EHTAH) with tap water as a working fluid. However, tap water at room temperature is not a proper substitute for blood at 37 degrees C. We therefore investigated MHV cavitation using a glycerin solution that was identical in viscosity and vapor pressure to blood at body temperature. In this study, six different kinds of monoleaflet and bileaflet valves were mounted in the mitral position in an EHTAH, and we investigated the mechanisms for MHV cavitation. The valve closing velocity, pressure drop measurements, and a high-speed video camera were used to investigate the mechanism for MHV cavitation and to select the best MHV for our EHTAH. The closing velocity of the bileaflet valves was slower than that of the monoleaflet valves. Cavitation bubbles were concentrated on the edge of the valve stop and along the leaflet tip. It was established that squeeze flow holds the key to MHV cavitation in our study. Cavitation intensity increased with an increase in the valve closing velocity and the valve stop area. With regard to squeeze flow, the Björk-Shiley valve, because it is associated with slow squeeze flow, and the bileaflet valve with low valve closing velocity and small valve stop areas are better able to prevent blood cell damage than the monoleaflet valves.

  13. Energy Regeneration Hydraulic System via a Relief Valve with Energy Regeneration Unit

    Directory of Open Access Journals (Sweden)

    Tianliang Lin

    2017-06-01

    Full Text Available Relief valves are widely used in industrial machinery. Due to the outlet of the relief valve being connected to the tank, the pressure drop of the relief valve is frequently equal to the inlet pressure. Accordingly, the energy loss of the relief valve is very high in some cases and this will worsen with an increase in the rated pressure of the hydraulic system. In order to overcome the disadvantage of overflow energy loss in a relief valve, a hydraulic energy regeneration unit (HERU is connected to the outlet of the relief valve to decrease the pressure drop between the inlet and outlet of the relief valve. The overflow loss, which is characterized by the pressure drop, can be reduced accordingly. The approach is to convert the overflow energy loss in hydraulic form and allow for release when needed. The configuration and working principle of the relief valve with HERU is introduced in this present study. The mathematical model is established to obtain the factors influencing the stability of the relief valve. The working pressure of the hydraulic accumulator (HA is explored. Furthermore, the control process of the operating state of the HA is scheduled to decide whether to regenerate the energy via the HERU. The software AMESim is utilized to analyze the performance and characteristics of the relief valve with HERU. Following this, the test rig is built and used to verify the effectiveness of the proposed relief valve with HERU. The experimental results show that the relief valve with the HERU connected to its outlet can still achieve better pressure-regulating characteristics. The energy regeneration efficiency saved by the HA is up to 83.6%, with a higher pre-charge pressure of the HA. This indicates that the proposed structure of the relief valve with HERU can achieve a better performance and higher regeneration efficiency.

  14. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2011-03-01

    The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range.

  15. Breaking Carbon Lock-in

    DEFF Research Database (Denmark)

    Driscoll, Patrick Arthur

    2014-01-01

    This central focus of this paper is to highlight the ways in which path dependencies and increasing returns (network effects) serve to reinforce carbon lock-in in large-scale road transportation infrastructure projects. Breaking carbon lock-in requires drastic changes in the way we plan future...

  16. Replaceable valve seat

    Science.gov (United States)

    Jordan, Raymond W.

    1992-01-01

    A valve with an O-ring, a disk seal, and a replaceable valve seat is presented. A groove in the bottom on the valve seat flange forms an inner and outer drip ledge with the inner and outer periphery of the flange. If leakage occurs at the valve seat O-ring, fluid droplets will form on the out drip ledge. If leakage occurs at the disk seal, fluid droplets will form on the inner drip ledge. A visual inspection of these drip ledges through an access port, or by a borescope placed in an inspection port, can discriminate between a leak which originates in the O-ring and a leak which originates in the disk seal. When conventional replaceable valve seats leak, fluid droplets form at the bottom on the valve seat. In the present invention, such a valve seat is modified by machining a groove on the bottom surface of the valve seat flange. This groove and the inner and outer surfaces of the flange intersect and form drip ledges. If leakage occurs at the valve seat seal, shown as an O-ring in the preferred embodiment, fluid droplets will form on the outer drip ledge. If leakage occurs at the valve disk seal, fluid droplets will form on the inner drip ledge. The drip ledges can be inspected either through an access port or by passing a borescope through a small inspection port in the valve case. Visual inspection of the bottom on the drip ledge will positively identify the required repair action.

  17. Valve reconstruction for congenital mitral valve disease.

    Science.gov (United States)

    Quinonez, Luis G; Del Nido, Pedro J

    2015-01-01

    The surgical treatment of mitral valve disease in children is a challenging problem. Mitral stenosis and regurgitation may occur in isolation or together. Mitral valve repair is almost always preferable to replacement. Mitral valve replacement is not an ideal alternative to repair due to limitations of size, growth, structural valve degeneration, anticoagulation and poor survival. Surgical repair of congenital mitral stenosis must address the multiple levels of obstruction, including resection of the supramitral ring, thinning of leaflets and mobilization of the subvalvular apparatus. Sometimes leaflet augmentation is required. Repair of mitral regurgitation in children may involve simple cleft closures, edge-to-edge repairs, triangular resections and annuloplasties. Techniques used in adults, such as annuloplasty bands or artificial chords, may not be appropriate for children. Overall, an imperfect mitral valve repair may be more acceptable than the negative consequences of a replacement in a child. © The Author 2015. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  18. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  19. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ...

  20. Mitral Valve Prolapse

    Science.gov (United States)

    ... State SELECT YOUR LANGUAGE Español (Spanish) 简体中文 (Traditional Chinese) 繁体中文 (Simplified Chinese) Tiếng Việt (Vietnamese) Healthy Living for Heart.org ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ...

  1. Mitral Valve Disease

    Science.gov (United States)

    ... clots, but they also are less durable than mechanical valves and may need to be replaced in the future. Like mitral valve repair, replacement can be done minimally invasively or with traditional open heart surgery. Your medical team will discuss the advantages ...

  2. Optimum design of seat region in valves suitable for digital displacement machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Pedersen, Henrik C.

    2014-01-01

    is optimised considering both the mechanical strength during pressure loading and fluid flow restriction in the open valve state. Material stresses are modelled using finite element (FE) analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting......Digital displacement fluid power is an upcoming technology setting new standards for the achievable efficiency in variable displacement fluid power pumps and motors. In the present work, an annular seat valve suitable for use in digital displacement units is considered, and the valve geometry...... the actual load of the seat valve connected to a fluid pressure chamber. Valve pressure losses are modelled using computational fluid dynamics (CFD). On basis of an overall physical size requirement and material specification, optimum valve geometry and stroke length are given as function of a defined...

  3. Cracking pressure control of parylene checkvalve using slanted tensile tethers

    OpenAIRE

    Lin, Jeffrey Chun-Hui; Yu, Feiqiao; Tai, Yu-Chong

    2010-01-01

    MEMS check valves with fixed cracking pressures are important in micro-fluidic applications where the pressure, flow directions and flow rates all need to be carefully controlled. This work presents a new surface-micromachined parylene check valve that uses residual thermal stress in the parylene to control its cracking pressure. The new check valve uses slanted tethers to allow the parylene tensile stress to apply a net downward force on the valving seat against the orifice. The angle of the...

  4. Evaluation of mitral valve replacement anchoring in a phantom

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Lang, Pencilla; Bainbridge, Dan; Campbell, Gordon; Jones, Doug L.; Guiraudon, Gerard M.; Peters, Terry M.

    2012-02-01

    Conventional mitral valve replacement requires a median sternotomy and cardio-pulmonary bypass with aortic crossclamping and is associated with significant mortality and morbidity which could be reduced by performing the procedure off-pump. Replacing the mitral valve in the closed, off-pump, beating heart requires extensive development and validation of surgical and imaging techniques. Image guidance systems and surgical access for off-pump mitral valve replacement have been previously developed, allowing the prosthetic valve to be safely introduced into the left atrium and inserted into the mitral annulus. The major remaining challenge is to design a method of securely anchoring the prosthetic valve inside the beating heart. The development of anchoring techniques has been hampered by the expense and difficulty in conducting large animal studies. In this paper, we demonstrate how prosthetic valve anchoring may be evaluated in a dynamic phantom. The phantom provides a consistent testing environment where pressure measurements and Doppler ultrasound can be used to monitor and assess the valve anchoring procedures, detecting pararvalvular leak when valve anchoring is inadequate. Minimally invasive anchoring techniques may be directly compared to the current gold standard of valves sutured under direct vision, providing a useful tool for the validation of new surgical instruments.

  5. Compressed gas domestic aerosol valve design using high viscous product

    Directory of Open Access Journals (Sweden)

    A Nourian

    2016-10-01

    Full Text Available Most of the current universal consumer aerosol products using high viscous product such as cooking oil, antiperspirants, hair removal cream are primarily used LPG (Liquefied Petroleum Gas propellant which is unfriendly environmental. The advantages of the new innovative technology described in this paper are: i. No butane or other liquefied hydrocarbon gas is used as a propellant and it replaced with Compressed air, nitrogen or other safe gas propellant. ii. Customer acceptable spray quality and consistency during can lifetime iii. Conventional cans and filling technology There is only a feasible energy source which is inert gas (i.e. compressed air to replace VOCs (Volatile Organic Compounds and greenhouse gases, which must be avoided, to improve atomisation by generating gas bubbles and turbulence inside the atomiser insert and the actuator. This research concentrates on using "bubbly flow" in the valve stem, with injection of compressed gas into the passing flow, thus also generating turbulence. The new valve designed in this investigation using inert gases has advantageous over conventional valve with butane propellant using high viscous product (> 400 Cp because, when the valving arrangement is fully open, there are negligible energy losses as fluid passes through the valve from the interior of the container to the actuator insert. The use of valving arrangement thus permits all pressure drops to be controlled, resulting in improved control of atomising efficiency and flow rate, whereas in conventional valves a significant pressure drops occurs through the valve which has a complex effect on the corresponding spray.

  6. Transcatheter aortic valve implantation for bicuspid aortic valve stenosis.

    Science.gov (United States)

    Hamdan, Ashraf; Kornowski, Ran

    2015-08-01

    In Preprocedural CT, patients with BAV have larger aortic annulus perimeters, and more calcified valves compared with TAV. In patients with BAV, self-expandable valves were under-expand and balloon-expandable valves have a trend toward increased rates of postimplantation AR grade. Self-expandable valves have higher postprocedural gradient in BAV compared with TAV. © 2015 Wiley Periodicals, Inc.

  7. Degenerative processes in bioprosthetic mitral valves in juvenile pigs

    Directory of Open Access Journals (Sweden)

    Pedersen Torben B

    2011-05-01

    Full Text Available Abstract Background Glutaraldehyde-treated bioprosthetic heart valves are commonly used for replacement of diseased heart valves. However, calcification and wear limit their durability, and the development of new and improved bioprosthetic valve designs is needed and must be evaluated in a reliable animal model. We studied glutaraldehyde-treated valves 6 months after implantation to evaluate bioprosthetic valve complications in the mitral position in juvenile pigs. Materials The study material comprised eight, 5-month old, 60-kg pigs. All pigs received a size 27, glutaraldehyde-treated, stented, Carpentier-Edwards S.A.V. mitral valve prosthesis. After six months, echocardiography was performed, and the valves explanted for gross examination, high resolution X-ray, and histological evaluation. Results Five pigs survived the follow-up period. Preexplant echocardiography revealed a median peak and mean velocity of 1.61 m/s (range: 1.17-2.00 and 1.20 (SD = ±0.25, respectively, and a median peak and mean pressure difference of 10.42 mmHg (range: 5.83-16.55 and 6.51 mmHg (SD = ±2.57, respectively. Gross examination showed minor thrombotic depositions at two commissures in two valves and at all three commissures in three valves. High resolution X-ray imaging revealed different degrees of calcification in all explanted valves, primarily in the commissural and belly areas. In all valves, histological evaluation demonstrated various degrees of fibrous sheath formation, limited immunological infiltration, and no overgrowth of host endothelium. Conclusions Bioprosthetic glutaraldehyde-treated mitral valves can be implanted into the mitral position in pigs and function after 6 months. Echocardiographic data, calcification, and histological examinations were comparable to results obtained in sheep models and human demonstrating the suitability of the porcine model.

  8. Application of new designed butterfly type intermediate valve for nuclear steam turbine

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Kazuhiro; Kawamata, Susumu (Tokyo Electric Power Co., Inc. (Japan)); Fujita, Isao; Taketomo, Seiki

    1991-09-01

    To cope with a large capacity nuclear steam turbine, a butterfly type intermediate valve has been developed. Compared to the conventional valve, or globe valve, the butterfly valve has the following design features: (a) Higher thermal efficiency due to lower pressure loss, (b) Easier maintenance due to simplified construction, and (c) Lower station cost due to the smaller size of the valve assembly. An experiment with a scaled-down test valve was carried out using compressed air. Subsequently a full-scale valve was tested using steam under actual steam conditions. As a result, these tests gave us no problems. The first nuclear turbine (1100MW) equipped with a butterfly valve is operating satisfactorily with good performance as expected. (author).

  9. Experimental study for flow characteristics and performance evaluation of butterfly valves

    Science.gov (United States)

    Kim, C. K.; Yoon, J. Y.; Shin, M. S.

    2010-08-01

    The industrial butterfly valves have been applied to transport a large of fluid with various fields of industry. Also, these are mainly used a control of fluid flux to the water and waste-water pipeline. Present, butterfly valves are manufacturing for multiplicity shape of bodies and discs with many producers. However, appropriate performance evaluation was not yet accomplished to compare about these valves through experiments. This study is performed the experiment of flow characteristics and performance of manufactured 400A butterfly valves for the water and waste pipeline, and compared experimental results. We performed experiments that were controlled fixed a differential pressure condition (1 psi) and the range of the flow rate conditions (500 m3/hr ~ 2500 m3/hr), and also opened the disc of valves to a range of angle from 9 degree to 90 degree. We investigated and compared the valve flow coefficient and the valve loss coefficient of results through experiments with each butterfly valve.

  10. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  11. Is John Locke a democrat?

    DEFF Research Database (Denmark)

    Svensson, Palle

      Over recent years there has been a tendency to present John Locke as an equalitarian democrat (Ashcraft) and being close to the political views of the levellers (Waldron). This is not a completely new interpretation (Kendall, 1941), but contrasts with the prevalent view presented in textbooks...... (Holden, Held, Ball and Dagger) and monographs on Locke (Dunn, Parry, Marshall). In this paper a new approach to the democratic character of John Locke's political theory is suggested, as his Second Treatise is analysed with Robert A. Dahl's conceptual framework on assumptions for a democratic order...

  12. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    Science.gov (United States)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  13. Flow characteristics and performance evaluation of butterfly valves using numerical analysis

    Science.gov (United States)

    Jeon, S. Y.; Yoon, J. Y.; Shin, M. S.

    2010-08-01

    The industrial butterfly valves have been applied to various fields that transport fluid in volume, especially water supply and drainage pipeline for flow control. The butterfly valves in various shapes are manufactured, but a fitting performance comparison is not made up. For this reason, we carried out numerical analysis of some kind of butterfly valves for water supply and drainage pipeline using commercial CFD code FLUENT, and made a comparative study of these results. Also, the flow coefficient, the loss coefficient, and pressure distribution of valves according to valve opening rate were compared each other and the influence of these design variables on valve performance were checked over. Through flow around the valve disk, such as pressure distribution, flow pattern, velocity vectors, and form of vortex, we grasped flow characteristics.

  14. Experimental investigation of the check valve behaviour when the flow is reversing

    Directory of Open Access Journals (Sweden)

    Himr D.

    2017-01-01

    Full Text Available Check valve in a pipeline is supposed to prevent the reverse flow and to allow the flow in the positive direction. The construction of check valves follows these requirements, but the check valve must not cause pressure pulsations in transients. It means when the fluid is accelerating or decelerating. The article describes an experimental investigation of a swing check valve when the flow is changing its direction. The check valve was placed in an experimental circuit, where the pressure on the upstream and downstream side of the valve was measured and the current value of flow rate was determined. The goal was to simulate conditions in the real system, where the check valve slam had been observed.

  15. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  16. Tissue Heart Valve Replacement at BSMMU- Initial Experience with Two Cases

    Directory of Open Access Journals (Sweden)

    Rezwanul Hoque

    2010-07-01

    Full Text Available Research on prosthesis to replace diseased heart valves began almost simultaneously with mechanical valves which aredurable but with inherent thromboembolic complication requiring life-long anticoagulant therapy and tissue valves whichare more prone to structural failure but free from thromboembolic complication. Tissue valves are more useful in females ofreproductive age desiring a child, male patients older than 60 years of age and female patients over 55 years of age, patientshaving chronic liver disease, history of stroke, bleeding disorder and in presence of infective endocarditis. Gluteraldehydefixation at low pressure with removal of maximal amount of phospholipid have increased the durability of tissue valves inrecent years. Considering the better quality of life with tissue valve the trend is shifting towards using it more frequentlyaround the world. Recently two heart valve replacement operations using bovine perimount pericardial valve were done inthe department of cardiac surgery, BSMMU, one in aortic position another in mitral position, both in females of reproductiveage desiring children.The operations were technically demanding but the outcomes were uneventful. Tissue heart valvereplacement is a safe procedure and can be useful in female of child bearing age desiring children.Key Words: Tissue heart valve replacement; Aortic valve; Mitral valve; Bioprosthetic heart valves; Bovine perimountpericardial valve.DOI: 10.3329/bsmmuj.v3i1.5511BSMMU J 2010; 3(1: 27-30

  17. 49 CFR 236.765 - Locking, mechanical.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, mechanical. 236.765 Section 236.765 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, mechanical. An arrangement of locking bars, dogs, tappets, cross locking and other apparatus by...

  18. 49 CFR 236.336 - Locking bed.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking bed. 236.336 Section 236.336 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Instructions § 236.336 Locking bed. The various parts of the locking bed, locking bed supports, and tappet stop...

  19. Dually-mode-locked ND: YAG laser

    Science.gov (United States)

    Osmundson, J.; Rowe, E.; Santarpia, D.

    1974-01-01

    Mode-locking is stabilized effectively by conventional loss-modulator and phase-modulator, mode-locking elements placed in laser cavity in optical series with one another. Resulting dually-mode-locked system provides pulses with constant phase relative to mode-lock drive signal without presence of relaxation oscillation noise.

  20. Piezo pump and pressurized circuit provided therewith

    NARCIS (Netherlands)

    Van Es, Johannes; Wits, Wessel Willems

    2015-01-01

    A piezo pump for use in a pressurized circuit includes a pump chamber with an inlet provided with a one way inlet valve, for connection to a feeding line of the pressurized circuit and an outlet provided with a one way outlet valve, for connection to a discharge line of the pressurized circuit and a

  1. Experimental apparatus to test air trap valves

    Science.gov (United States)

    Lemos De Lucca, Y. de F.; de Aquino, G. A.; Filho, J. G. D.

    2010-08-01

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through "air trap valves". In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the "air trap valves". The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where "air trap valves" are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test "air trap valves". The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  2. Experimental apparatus to test air trap valves

    Energy Technology Data Exchange (ETDEWEB)

    Lemos De Lucca, Y de F [CTH-DAEE-USP/FAAP/UNICAMP (Brazil); Aquino, G A de [SABESP/UNICAMP (Brazil); Filho, J G D, E-mail: yvone.lucca@gmail.co [Water Resources Department, University of Campinas-UNICAMP, Av. Albert Einstein, 951, Cidade Universitaria-Barao Geraldo-Campinas, S.P., 13083-852 (Brazil)

    2010-08-15

    It is known that the presence of trapped air within water distribution pipes can lead to irregular operation or even damage to the distribution systems and their components. The presence of trapped air may occur while the pipes are being filled with water, or while the pumping systems are in operation. The formation of large air pockets can produce the water hammer phenomenon, the instability and the loss of pressure in the water distribution networks. As a result, it can overload the pumps, increase the consumption of electricity, and damage the pumping system. In order to avoid its formation, all of the trapped air should be removed through 'air trap valves'. In Brazil, manufacturers frequently have unreliable sizing charts, which cause malfunctioning of the 'air trap valves'. The result of these malfunctions causes accidents of substantial damage. The construction of a test facility will provide a foundation of technical information that will be used to help make decisions when designing a system of pipelines where 'air trap valves' are used. To achieve this, all of the valve characteristics (geometric, mechanic, hydraulic and dynamic) should be determined. This paper aims to describe and analyze the experimental apparatus and test procedure to be used to test 'air trap valves'. The experimental apparatus and test facility will be located at the University of Campinas, Brazil at the College of Civil Engineering, Architecture, and Urbanism in the Hydraulics and Fluid Mechanics laboratory. The experimental apparatus will be comprised of various components (pumps, steel pipes, butterfly valves to control the discharge, flow meter and reservoirs) and instrumentation (pressure transducers, anemometer and proximity sensor). It should be emphasized that all theoretical and experimental procedures should be defined while taking into consideration flow parameters and fluid properties that influence the tests.

  3. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  4. pH-Sensitive Hydrogel for Micro-Fluidic Valve

    Directory of Open Access Journals (Sweden)

    Zhengzhi Yang

    2012-07-01

    Full Text Available The deformation behavior of a pH-sensitive hydrogel micro-fluidic valve system is investigated using inhomogeneous gel deformation theory, in which the fluid-structure interaction (FSI of the gel solid and fluid flow in the pipe is considered. We use a finite element method with a well adopted hydrogel constitutive equation, which is coded in commercial software, ABAQUS, to simulate the hydrogel valve swelling deformation, while FLUENT is adopted to model the fluid flow in the pipe of the hydrogel valve system. The study demonstrates that FSI significantly affects the gel swelling deformed shapes, fluid flow pressure and velocity patterns. FSI has to be considered in the study on fluid flow regulated by hydrogel microfluidic valve. The study provides a more accurate and adoptable model for future design of new pH-sensitive hydrogel valves, and also gives a useful guideline for further studies on hydrogel fluidic applications.

  5. Design of pneumatic proportional flow valve type 5/3

    Science.gov (United States)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  6. Hemodynamics and Mechanobiology of Aortic Valve Inflammation and Calcification

    Directory of Open Access Journals (Sweden)

    Kartik Balachandran

    2011-01-01

    Full Text Available Cardiac valves function in a mechanically complex environment, opening and closing close to a billion times during the average human lifetime, experiencing transvalvular pressures and pulsatile and oscillatory shear stresses, as well as bending and axial stress. Although valves were originally thought to be passive pieces of tissue, recent evidence points to an intimate interplay between the hemodynamic environment and biological response of the valve. Several decades of study have been devoted to understanding these varied mechanical stimuli and how they might induce valve pathology. Here, we review efforts taken in understanding the valvular response to its mechanical milieu and key insights gained from in vitro and ex vivo whole-tissue studies in the mechanobiology of aortic valve remodeling, inflammation, and calcification.

  7. John locke on personal identity.

    Science.gov (United States)

    Nimbalkar, Namita

    2011-01-01

    John Locke speaks of personal identity and survival of consciousness after death. A criterion of personal identity through time is given. Such a criterion specifies, insofar as that is possible, the necessary and sufficient conditions for the survival of persons. John Locke holds that personal identity is a matter of psychological continuity. He considered personal identity (or the self) to be founded on consciousness (viz. memory), and not on the substance of either the soul or the body.

  8. FLUID MECHANICS OF ARTIFICIAL HEART VALVES

    OpenAIRE

    Dasi, Lakshmi P; Simon, Helene A; Sucosky, Philippe; Yoganathan, Ajit P

    2009-01-01

    1. Artificial heart valves have been in use for over five decades to replace diseased heart valves. Since the first heart valve replacement performed with a caged-ball valve, more than 50 valve designs have been developed, differing principally in valve geometry, number of leaflets and material. To date, all artificial heart valves are plagued with complications associated with haemolysis, coagulation for mechanical heart valves and leaflet tearing for tissue-based valve prosthesis. For mecha...

  9. Variable Valve Timing Scheduling in a 4-Stroke Internal Combustion Cylinder Utilizing Artificial Neural Networks

    Directory of Open Access Journals (Sweden)

    Sepehr Bapiri

    2017-09-01

    Full Text Available The apparently simple structure of a four-stroke internal combustion cylinder belies the complicated problem of optimizing valve operation in response to a change in crankshaft rotation speed. The objective of this study was to determine the cylinder pressure for valve event angles in order to determine the optimal strategy for the timing of valve events when independently-actuated valves are available. In this work, an artificial neural network is applied to create a prediction matrix to anticipate the best variable valve timing approach according to rotation speed.

  10. Characterization of Aortic Valve Closure Artifact During Outflow Tract Mapping: Correlation With Hemodynamics and Mechanical Valves.

    Science.gov (United States)

    Romero, Jorge; Ajijola, Olujimi; Shivkumar, Kalyanam; Tung, Roderick

    2017-06-01

    Premature ventricular contractions originating in the left ventricle outflow tract represent a significant subgroup of patients referred for catheter ablation. Mechanical artifacts from aortic valve leaflet motion may be observed during mapping, although the incidence and characteristics have not been reported. Twenty-eight consecutive patients with left ventricle outflow tract premature ventricular contraction were included. Electric signals recorded on the ablation catheter not coincident with atrial or ventricular depolarization were analyzed on the recording system. Correlation with invasive hemodynamic aortic pressure tracings was performed. Additionally, 4 patients with mechanical aortic valves, who underwent scar-related ventricular tachycardia ablation, were analyzed to correlate the timing of the observed artifacts with native aortic valves. Aortic valve artifact was observed while mapping within the coronary cusps in 11 patients (39%; 73% men; age, 41±25 years; left ventricular ejection fraction 49±16%) with high incidence from the left coronary cusp. This artifact was consistently observed with timing coincident with the terminal portion of the T wave. The average interval between the end of the T wave and the aortic valve artifact was 19±37 ms. The duration of the aortic valve artifact was 39±8 ms with amplitude of 0.12±0.07 mV (range, 0.06-0.36 mV). In patients referred for left ventricle outflow tract premature ventricular contraction ablation, an aortic valve closure artifact is observed in up to one third of cases during mapping within the aortic cusps. The timing of this artifact correlates with invasive hemodynamics and mechanical aortic valve artifacts. Recognition of this physiological phenomenon is useful when assigning near-field activation. © 2017 American Heart Association, Inc.

  11. 46 CFR 53.05-1 - Safety valve requirements for steam boilers (modifies HG-400 and HG-401).

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 2 2010-10-01 2010-10-01 false Safety valve requirements for steam boilers (modifies HG... requirements for steam boilers (modifies HG-400 and HG-401). (a) The pressure relief valve requirements and the safety valve requirements for steam boilers must be as indicated in HG-400 and HG-401 of section IV of...

  12. Mitral valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... stroke. Valves made from human or animal tissue fail over time. They have an average lifespan of ...

  13. Valve Repair or Replacement

    Science.gov (United States)

    ... valve surgery can be done using a robot. Robotic surgery does not require a large incision in the ... The Texas Heart Institute has a robot. With robotic surgery, the surgeon has a control console, a side ...

  14. Aortic Valve Regurgitation

    Science.gov (United States)

    ... valves. Rheumatic fever. Rheumatic fever — a complication of strep throat and once a common childhood illness in the ... a severe sore throat, see a doctor. Untreated strep throat can lead to rheumatic fever. Fortunately, strep throat ...

  15. Cardiac energetics analysis after aortic valve replacement with 16-mm ATS mechanical valve.

    Science.gov (United States)

    Ushijima, Tomoki; Tanoue, Yoshihisa; Uchida, Takayuki; Matsuyama, Sho; Matsumoto, Takashi; Tominaga, Ryuji

    2014-09-01

    The 16-mm ATS mechanical valve is one of the smallest prosthetic valves used for aortic valve replacement (AVR) in patients with a very small aortic annulus, and its clinical outcomes are reportedly satisfactory. Here, we analyzed the left ventricular (LV) performance after AVR with the 16-mm ATS mechanical valve, based on the concept of cardiac energetics analysis. Eleven patients who underwent AVR with the 16-mm ATS mechanical valve were enrolled in this study. All underwent echocardiographic examination at three time points: before AVR, approximately 1 month after AVR, and approximately 1 year after AVR. LV contractility (end-systolic elastance [Ees]), afterload (effective arterial elastance [Ea]), and efficiency (ventriculoarterial coupling [Ea/Ees] and the stroke work to pressure-volume area ratio [SW/PVA]) were noninvasively measured by echocardiographic data and blood pressure measurement. Ees transiently decreased after AVR and then recovered to the pre-AVR level at the one-year follow-up. Ea significantly decreased in a stepwise manner. Consequently, Ea/Ees and SW/PVA were also significantly improved at the one-year follow-up compared with those before AVR. The midterm LV performance after AVR with the 16-mm ATS mechanical valve was satisfactory. AVR with the 16-mm ATS mechanical valve is validated as an effective treatment for patients with a very small aortic annulus. The cardiac energetics variables, coupling with the conventional hemodynamic variables, can contribute to a better understanding of the patients' clinical conditions, and those may serve as promising indices of the cardiac function.

  16. Mapping fluids to subduction megathrust locking and slip behavior

    Science.gov (United States)

    Saffer, Demian M.

    2017-09-01

    In subduction zones, high fluid content and pore pressure are thought to promote aseismic creep, whereas well-drained conditions are thought to promote locking and failure in earthquakes. However, observations directly linking fluid content and seismic coupling remain elusive. Heise et al. (2017) use a magnetotelluric survey to image the electrical resistivity structure of the northern Hikurangi subduction thrust to 30 km depth, as an indicator of interconnected fluid content. The authors document a clear correlation between high resistivity and a distinct geodetically locked patch and between conductive areas and weak coupling. Their study, together with other recent geophysical investigations, provides new evidence for the role of fluids in governing subduction thrust locking.

  17. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  18. Applicability of handmade expanded polytetrafluoroethylene trileaflet-valved conduits for pulmonary valve reconstruction: An ex vivo and in vivo study.

    Science.gov (United States)

    Kan, Chung-Dann; Wang, Jieh-Neng; Chen, Wei-Ling; Lu, Pong-Jeu; Chan, Ming-Yao; Lin, Chia-Hung; Hsieh, Wan-Chin

    2017-09-20

    The handmade expanded polytetrafluoroethylene (ePTFE) trileaflet-valved conduit could potentially be used as a substitute pulmonary valve replacement material, especially in children. The current study investigated (1) the function of the ePTFE trileaflet-valved conduits in an ex vivo experimental system and (2) the short-term performance of the conduit in a porcine model to verify its clinical applicability. The competency of the ePTFE trileaflet-valved conduits was estimated through ex vivo (using a pulmonary mock circulation loop) and in vivo (in a porcine model with a damaged pulmonary valve) experiments. Explants were examined by gross morphology and histopathologic examination. In the ex vivo experiment, the ePTFE trileaflet-valved conduits were determined to effectively increase mean pulmonary pressure from 10.2 to 14.4 mm Hg compared with defective silicon-valved conduits. In addition, the regurgitation fraction value of ePTFE trileaflet-valved conduits was 15.9% to 18.1%, which was significantly better than the defective valve conduits (regurgitation fraction = 73.5%-85.7%). In the in vivo experiment, the valved conduits were confirmed to be with good valve position maintenance, and the valve and leaflets showed no signs of thickening or peeling after a short-term implantation period. There were also no significant signs of inflammation reaction on histopathologic examination. The ePTFE trileaflet-valved conduits for pulmonary valve reconstruction showed acceptable performance and outcomes in the ex vivo and in vivo experiments. The ePTFE trileaflet-valved conduit may be clinically useful, although additional studies in animals should be conducted to determine its long-term outcomes. Copyright © 2017 The American Association for Thoracic Surgery. Published by Elsevier Inc. All rights reserved.

  19. Hydrodynamic characterization of a passive shape memory alloy valve

    Science.gov (United States)

    Waddell, A. M.; Punch, J.; Stafford, J.; Jeffers, N.

    2014-07-01

    Next generation high-performance electronics will have large heat fluxes (>102 W/cm2) and an alternative approach to traditional air cooling is required. An attractive solution is micro-channel cooling and micro-valves will be required for refined flow control in the supporting micro-fluidic systems. A NiTi Shape Memory Alloy (SMA) micro-valve design was hydrodynamically characterized in this work to obtain the valve loss coefficient (K) from pressure measurements. The hydrodynamic characterization was important as in the flow regime of the micro-fluidic system K is sensitive to Reynolds number (Re) and geometry. Static replicas of the SMA valve geometry were studied for low Reynolds numbers (110 - 220) in a 1x1 mm CSA miniature channel. The loss coefficients were found to be sensitive to flow rate and decreased rapidly with an increase in Re. The SMA valve was compared to a similar gate micro-valve and loss across both valves was of the same order of magnitude. The valve loss coefficients obtained in this work are important parameters in the modeling and design of micro-fluidic cooling systems.

  20. Phase separator safety valve blow-off.

    CERN Multimedia

    G. Perinic

    2006-01-01

    The fast discharge of the CMS solenoid leads to a pressure rise in the phase separator. On August 28th, a fast discharge was triggered at a current level of 19.1 kA. The pressure in the phase separator increased up to the set pressure of the safety valve and some helium was discharged. In consequence of this and prevoious similar observations the liquid helium level in the phase separator has been reduced from 60% to 50% and later to 45% in order to reduce the helium inventory in the magnet.

  1. Development of a control system for compression and expansion cycles of critical valve for high vacuum systems

    Energy Technology Data Exchange (ETDEWEB)

    Agarwal, Jyoti, E-mail: jagarwal@ipr.res.in; Sharma, H.; Patel, Haresh; Gangradey, R.; Lambade, Vrushabh

    2016-11-15

    Highlights: • Control system with feedback loop of pressure gauge is developed for measuring the life cycle of vacuum isolation valve. • GUI based software developed for easy use and handling of control system. • Control system tested with an experiment showcasing the capability of the control system. • Control system can operate valve based on pressure inside the chamber, which helps to know the degradation of sealing capabilities of valve. • Control system can monitor the total closing and opening time of valve, cycles and pressure inside the vessel. - Abstract: A control system with feedback loop is designed, developed and tested to monitor the life cycles of the axial valve and bellows used in vacuum valves. The control system monitors number of compression cycles of any bellow or closing and opening cycle of a valve. It also interfaces vacuum gauges or pressure gauges to get pressure values inside the system. To find life cycle of valve, the developed control and monitoring system is integrated with an axial valve experimental test set up. In this system, feedback from the vacuum gauge attached to valve enclosure, is given and the life cycle test is automated. This paper describes the control and monitoring system in details and briefs the experiment carried out for valve life cycle. The same system can be used for life cycle estimate for bellows. A suitable GUI is also developed to control the function of the components and resister the number of cycles.

  2. Medicine in John Locke's philosophy.

    Science.gov (United States)

    Sanchez-Gonzalez, M A

    1990-12-01

    John Locke's philosophy was deeply affected by medicine of his times. It was specially influenced by the medical thought and practice of Thomas Sydenham. Locke was a personal friend of Sydenham, expressed an avid interest in his work and shared his views and methods. The influence of Sydenham's medicine can be seen in the following areas of Locke's philosophy: his "plain historical method"; the emphasis on observation and sensory experience instead of seeking the essence of things; the rejection of hypotheses and principles; the refusal of research into final causes and inner mechanisms; the ideal of irrefutable evidence and skepticism on the possibilities of certainty in science. The science which for Locke held the highest paradigmatic value in his theory of knowledge was precisely medicine. To a great extent, Locke's Essay on Human Understanding can be understood as an attempt to justify, substantiate, and promote Sydenham's medical method. This method, generalized, was then proposed as an instrument for the elaboration of all natural sciences.

  3. How Is Heart Valve Disease Treated?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  4. How Is Heart Valve Disease Diagnosed?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  5. When a Heart Murmur Signals Valve Disease

    Science.gov (United States)

    ... Order AHA Brochures Your Heart Valve Surgery Your Mitral Valve Prolapse Innocent Heart Murmurs If Your Child Has a Congenital Heart Defect See all of our brochures Valve Disease Resources Patient Guide: Understanding Your Heart Valve Problem | ...

  6. The healing philosopher: John Locke's medical ethics.

    Science.gov (United States)

    Short, Bradford William

    2004-01-01

    This article examines a heretofore unexplored facet of John Locke's philosophy. Locke was a medical doctor and he also wrote about medical issues that are controversial today. Despite this, Locke's medical ethics has yet to be studied. An analysis of Locke's education and his teachers and colleagues in the medical profession, of the 17th century Hippocratic Oath, and of the reaction to the last recorded outbreak of the bubonic plague in London, shines some light on the subject of Locke's medical ethics. The study of Locke's medical ethics confirms that he was a deontologist who opposed all suicide and abortion through much of pregnancy.

  7. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  8. Clamp Restrains Pressure Line

    Science.gov (United States)

    Aliberti, J. A.

    1982-01-01

    Safety restraint protects people and property if a high-pressure fitting fails. As long as pressure line remains attached at the fitting, clamp exerts essentially no force on hose. If fitting fails, force of fluid leaving free end of hose causes the cam on the clamp to compress hose with a positive locking action.

  9. Development and multiplexed control of latching pneumatic valves using microfluidic logical structures.

    Science.gov (United States)

    Grover, William H; Ivester, Robin H C; Jensen, Erik C; Mathies, Richard A

    2006-05-01

    Novel latching microfluidic valve structures are developed, characterized, and controlled independently using an on-chip pneumatic demultiplexer. These structures are based on pneumatic monolithic membrane valves and depend upon their normally-closed nature. Latching valves consisting of both three- and four-valve circuits are demonstrated. Vacuum or pressure pulses as short as 120 ms are adequate to hold these latching valves open or closed for several minutes. In addition, an on-chip demultiplexer is demonstrated that requires only n pneumatic inputs to control 2(n-1) independent latching valves. These structures can reduce the size, power consumption, and cost of microfluidic analysis devices by decreasing the number of off-chip controllers. Since these valve assemblies can form the standard logic gates familiar in electronic circuit design, they should be useful in developing complex pneumatic circuits.

  10. Coupled optical resonance laser locking.

    Science.gov (United States)

    Burd, S C; du Toit, P J W; Uys, H

    2014-10-20

    We have demonstrated simultaneous laser frequency stabilization of a UV and IR laser, to coupled transitions of ions in the same spectroscopic sample, by detecting only the absorption of the UV laser. Separate signals for locking the different lasers are obtained by modulating each laser at a different frequency and using lock-in detection of a single photodiode signal. Experimentally, we simultaneously lock a 369 nm and a 935 nm laser to the (2)S(1/2) → (2)(P(1/2) and (2)D(3/2) → (3)D([3/2]1/2) transitions, respectively, of Yb(+) ions generated in a hollow cathode discharge lamp. Stabilized lasers at these frequencies are required for cooling and trapping Yb(+) ions, used in quantum information and in high precision metrology experiments. This technique should be readily applicable to other ion and neutral atom systems requiring multiple stabilized lasers.

  11. Design of a lock-amplifier circuit

    Science.gov (United States)

    Liu, H.; Huang, W. J.; Song, X.; Zhang, W. Y.; Sa, L. B.

    2017-01-01

    The lock-in amplifier is recovered by phase sensitive detection technique for the weak signal submerged in the noise background. This design is based on the TI ultra low power LM358, INA129, OPA227, OP07 and other chips as the core design and production of the lock-in amplifier. Signal generator by 10m ohms /1K ohm resistance points pressure network 10 mu V 1mV adjustable sine wave signal s (T). The concomitant interference signal together through the AC amplifier and band-pass filter signal x (T), on the other hand reference signal R (T) driven by square wave phase shift etc. steps to get the signal R (T), two signals and by phase sensitive detector are a DC full wave, again through its low pass filter and a DC amplifier to be measured signal more accurate detection, the final circuit through the AD conversion and the use of single-chip will display the output.

  12. Reconfigurable Braille display with phase change locking

    Science.gov (United States)

    Soule, Cody W.; Lazarus, Nathan

    2016-07-01

    Automatically updated signs and displays for sighted people are common in today’s world. However, there is no cheap, low power equivalent available for the blind. This work demonstrates a reconfigurable Braille cell using the solid-to-liquid phase change of a low melting point alloy as a zero holding power locking mechanism. The device is actuated with the alloy in the liquid state, and is then allowed to solidify to lock the Braille dot in the actuated position. A low-cost manufacturing process is developed that includes molding of a rigid silicone to create pneumatic channels, and bonding of a thin membrane of a softer silicone on the surface for actuation. A plug of Field’s metal (melting point 62 °C) is placed in the pneumatic channels below each Braille dot to create the final device. The device is well suited for low duty cycle operation in applications such as signs, and is able to maintain its state indefinitely without additional power input. The display requires a pneumatic pressure of only 24 kPa for actuation, and reconfiguration has been demonstrated in less than a minute and a half.

  13. Pressure Effect on Extensional Viscosity

    DEFF Research Database (Denmark)

    Christensen, Jens Horslund; Kjær, Erik Michael

    1999-01-01

    The primary object of these experiments was to investigate the influence of hydrostatic pressure on entrance flow. The effect of pressure on shear and extensional viscosity was evaluated using an axis symmetric capillary and a slit die where the hydrostatic pressure was raised with valves....... The experiments show a significant increase in extensional viscosity with increasing pressure....

  14. Non-Pyrotechnic Zero-Leak Normally Closed Valve

    Science.gov (United States)

    Gillespie, Rebecca

    2010-01-01

    This valve is designed to create a zero-leak seal in a liquid propulsion system that is a functional replacement for the normally closed pyrovalve. Unlike pyrovalves, Nitinol is actuated by simply heating the material to a certain temperature, called the transition temperature. Like a pyrovalve, before actuation, the upstream and downstream sections are separated from one another and from the external environment by closed welded seals. Also like pyrovalves, after actuation, the propellant or pressurant gas can flow without a significant pressure drop but are still separated from the external environment by a closed welded seal. During manufacture, a Nitinol bar is compressed to 93 percent of its original length and fitted tightly into the valve. During operation, the valve is heated until the Nitinol reaches the transition temperature of 95 C; the Nitinol "remembers" its previous longer shape with a very large recovery force causing it to expand and break the titanium parent metal seal to allow flow. Once open, the valve forever remains open. The first prototype valve was designed for high pressure [5,000 psi (=34.5 MPa)] and low flow, typical requirements for pressurant gas valves in liquid propulsion systems. It is possible to modify the dimensions to make low-pressure models or high-flow models, for use downstream of the propellant tanks. This design is simpler, lower risk, and less expensive than the pyrovalve. Although the valve must be in a thermally controlled state (kept below 80 C) to prevent premature actuation, the pyrovalves and electrically actuated initiators have far more taxing handling requirements.

  15. Safety valve for offshore borehole

    Energy Technology Data Exchange (ETDEWEB)

    McGill, H.L.; Randermann, E. Jr.; Musik, O.J.

    1977-10-06

    The invention concerns a new and improved submarine safety valve with a valve element which rotate, which can be used, in emergencies, to separate the wound-up piping which extends into the borehole and to close the production line.

  16. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... diseases of the tricuspid valve are regurgitation and stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid ... the tricuspid valve may also be needed. Tricuspid Stenosis Tricuspid stenosis is a narrowing or blockage of ...

  17. Options for Heart Valve Replacement

    Science.gov (United States)

    ... valve: Aortic regurgitation , (sometimes referred to as aortic insufficiency) is another common valve problem that may require ... allows oxygenated blood to flow backwards into the lungs instead of continuing through the heart as it ...

  18. Line locking and SS 433

    Science.gov (United States)

    Pekarevich, M.; Piran, T.; Shaham, J.

    1984-01-01

    The general problem of acceleration by line locking in an optically thin medium is considered. Analytic solutions to the coupled equations of radiation transfer and matter motion are presented. Using these solutions, restrictions on the physical conditions of the accelerated matter are derived. By applying these conditions to SS 433, it is found that if the absorbing ion is light (hydrogen or helium), the matter must be highly clumped, and the acceleration has to begin at approximately 10 to the 12th cm. Line-locking acceleration with a hydrogen-like heavy ion such as iron demands higher than solar ion abundance.

  19. Locking mechanism for orthopedic braces

    Science.gov (United States)

    Chao, J. I.; Epps, C. H., Jr.

    1981-01-01

    An orthopedic brace locking mechanism is described which under standing or walking conditions cannot be unlocked, however under sitting conditions the mechanism can be simply unlocked so as to permit bending of the patient's knee. Other features of the device include: (1) the mechanism is rendered operable, and inoperable, dependent upon the relative inclination of the brace with respect to the ground; (2) the mechanism is automatically locked under standing or walking conditions and is manually unlocked under sitting conditions; and (3) the mechanism is light in weight and is relatively small in size.

  20. The study on flow characteristics of butterfly valve using flow visualization

    Energy Technology Data Exchange (ETDEWEB)

    Yang, S. M.; Hong, S. D.; Song, D. S.; Park, J. K.; Park, J. I.; Shin, S. K. [Hanbit Power Service, Daejeon (Korea, Republic of); Kim, H. J. [Ajou University, Suwon (Korea, Republic of)

    2005-07-01

    Flow visualization of butterfly valve is tested for four types(15 deg., 30 .deg., 45 .deg., and 90 .deg.) of valve opening angle. The inner flow characteristics of valve are studied. The flow variation was measured using a high speed camera which takes 500 frames per second with 1024 x 1024 pixels. These captured images were used for calculation to analyze two dimensional flow velocity of the valve. The smaller opening angle, the more increasing the differential pressure of a butterfly valve. Therefore, we know that the complex flow is occurred by increasing the differential pressure. And it is found that the flowing backward is more increased according to the increase of the opening angle of a butterfly valve. However, its flow pattern is similar to a simple pipe flow when the opening angle is 90 .deg.

  1. Low radiation dose non-contrast cardiac CT: is it of value in the evaluation of mechanical aortic valve

    Energy Technology Data Exchange (ETDEWEB)

    Bazeed, Mohamed Fayez (Dept. of Diagnostic Radiology, Faculty of Medicine, Mansoura Univ. (Egypt)), email: m_bazeed@yahoo.com; Moselhy, Mohamed Saleh (Cardiology Dept. Faculty of Medicine, Suez Canal Univ. (Egypt)); Rezk, Ahmad Ibrahim (Dept. of Cardiac Surgery, Faculty of Medicine, Aim Shams Univ. (Egypt)); Al-Murayeh, Mushabab Ayedh (Dept. of Cardiac Services, Armed Forces Hospitals Southern Region (Saudi Arabia))

    2012-05-15

    Background: Prosthetic bileaflet mechanical valve function has been traditionally evaluated using echocardiography and fluoroscopy. Multidetector computed tomography (MDCT) is a novel technique for cardiac evaluation. Purpose: To evaluate bileaflet mechanical aortic valves using a low-milliampere (mA), non-contrast MDCT protocol with a limited scan range. Material and Methods: Forty patients with a bileaflet mechanical aortic valve were evaluated using a non-contrast, low-mA, ECG-gated 64 MDCT protocol with a limited scan range. MDCT findings of opening and closing valve angles were correlated to fluoroscopy and echocardiography. Also, the valve visibility was evaluated on MDCT and fluoroscopy according to a 3-point grading scale. Results: The visualization score with the MDCT was significantly superior to the fluoroscopy (3 vs. 2.7). A strong correlation was noted between the opening (r = 0.82) and closing (r = 0.96) valve angles with MDCT and fluoroscopy without a statistically significant difference (P = 0.31 and 0.16, respectively). The mean effective radiation dose of the suggested protocol was 4 +- 0.5 mSv. Five valves were evaluated using transesophageal echocardiography because the valves were difficult to evaluate with transthoracic echocardiography, and all of these valves were evaluated optimally with MDCT. A high-pressure gradient was noted in nine valves, and the MDCT showed that seven of these valves inadequately opened, and two valves opened well, which resulted in patient valve mismatch. Incomplete valve closure was noted in five valves, and the echocardiography showed significant transvalvular regurgitation in all five valves. Conclusion: MDCT can provide a precise measurement of valve function and can potentially evaluate high-pressure gradients and transvalvular regurgitation

  2. Variable Valve Actuation

    Energy Technology Data Exchange (ETDEWEB)

    Jeffrey Gutterman; A. J. Lasley

    2008-08-31

    Many approaches exist to enable advanced mode, low temperature combustion systems for diesel engines - such as premixed charge compression ignition (PCCI), Homogeneous Charge Compression Ignition (HCCI) or other HCCI-like combustion modes. The fuel properties and the quantity, distribution and temperature profile of air, fuel and residual fraction in the cylinder can have a marked effect on the heat release rate and combustion phasing. Figure 1 shows that a systems approach is required for HCCI-like combustion. While the exact requirements remain unclear (and will vary depending on fuel, engine size and application), some form of substantially variable valve actuation is a likely element in such a system. Variable valve actuation, for both intake and exhaust valve events, is a potent tool for controlling the parameters that are critical to HCCI-like combustion and expanding its operational range. Additionally, VVA can be used to optimize the combustion process as well as exhaust temperatures and impact the after treatment system requirements and its associated cost. Delphi Corporation has major manufacturing and product development and applied R&D expertise in the valve train area. Historical R&D experience includes the development of fully variable electro-hydraulic valve train on research engines as well as several generations of mechanical VVA for gasoline systems. This experience has enabled us to evaluate various implementations and determine the strengths and weaknesses of each. While a fully variable electro-hydraulic valve train system might be the 'ideal' solution technically for maximum flexibility in the timing and control of the valve events, its complexity, associated costs, and high power consumption make its implementation on low cost high volume applications unlikely. Conversely, a simple mechanical system might be a low cost solution but not deliver the flexibility required for HCCI operation. After modeling more than 200 variations of

  3. Echocardiography of the mitral valve

    OpenAIRE

    Omran, A.S.; Arifi, A.A.; Mohamed, A.A.

    2010-01-01

    Mitral valve disease is the second most common valvular heart disease after the aortic valve worldwide. Mitral valve has historically been a structure of interest by pioneers in echocardiography. One of the earliest applications of echocardiography was in the diagnosis of valvular heart disease, particularly mitral stenosis. In this review we wish to take the reader through the structural and hemodynamic evaluation of the normal mitral valve.

  4. Internal Acoustics of a Pintle Valve with Supercritical Helium Flow

    Science.gov (United States)

    Fishbach, Sean R.; Davis, R. Benjamin

    2010-01-01

    Large amplitude flow unsteadiness is a common phenomenon within the high flow rate ducts and valves associated with propulsion systems. Boundary layer noise, shear layers and vortex shedding are a few of the many sources of flow oscillations. The presence of lightly damped acoustic modes can organize and amplify these sources of flow perturbation, causing undesirable loading of internal parts. The present study investigates the self-induced acoustic environment within a pintle valve subject to high Reynolds Number flow of helium gas. Experiments were conducted to measure the internal pressure oscillations of the Ares I Launch Abort System (LAS) Attitude Control Motor (ACM) valve. The AGM consists of a solid propellant gas generator with eight pintle valves attached to the aft end. The pintle valve is designed to deliver variable upstream conditions to an attache( converging diverging nozzle. In order to investigate the full range of operating conditions 28 separate tests were conducted with varying pintle position and upstream pressure. Helium gas was utilized in order to closely mimic the speed of sound of the gas generator exhaust, minimizing required scaling during data analysis. The recordec pressure measurements were interrogated to multiple ends. The development of root mean square (RMS) value! versus Reynolds Number and Pintle position are important to creating bounding unsteady load curves for valve internal parts. Spectral analysis was also performed, helping to identify power spectral densities (PSD) of acoustic natural frequencies and boundary layer noise. An interesting and unexpected result was the identification of an acoustic mode within the valve which does not respond until the valve was over 60% open. Further, the response amplitude around this mode can be as large or larger than those associated with lower frequency modes.

  5. Electromagnetically driven, fast opening and closing gas jet valve

    Directory of Open Access Journals (Sweden)

    Mahadevan Krishnan

    2011-03-01

    Full Text Available The design and performance are presented of an electromagnetically driven gas valve [M. Krishnan, J. Wright, and T. Ma, Proceedings of the 13th Advanced Accelerator Concepts Workshop, Santa Cruz, CA, AIP Conf. Proc. No. 1086 (AIP, New York, 2008] that opens in <100  μs, closes in <500  μs, and can operate at pressures of ∼1000  psia to drive supersonic nozzles. Such a valve has applications to laser-plasma accelerators, where the fast opening and closing would allow sharper edges to the flow and also allow higher rep-rate operation without loading the vacuum chamber. The valve action is effected by a flyer plate accelerated by the electromagnetic impulse of a low inductance, spiral wound, strip-line coil driven by a capacitor. Gas flows out of the valve when the seal between this flyer plate and the valve seat is broken. The electromagnetic force greatly exceeds the restoring forces provided by a spring and the gas pressure against the valve seat. Piezoresistive sensor and laser interferometer measurements of flow show that the valve opens in ∼100  μs for all pressures up to 800 psia. The closing time is 500  μs, set by the spring constant and mass. The prototype valve has been operated with helium at 0.5 Hz and at 500 psia for ∼1 hour at a time with no cooling.

  6. Considerations for Designing In Vitro Bioequivalence (IVBE) Studies for Pressurized Metered Dose Inhalers (pMDIs) with Spacer or Valved Holding Chamber (S/VHC) Add-on Devices.

    Science.gov (United States)

    Sandell, Dennis; Mitchell, Jolyon P

    2015-06-01

    The choice of analytical test methods and associated statistical considerations are considered for the laboratory testing of pressurized metered dose inhaler-spacer/valved holding chamber (pMDI-S/VHC) combinations for in vitro bioequivalence (IVBE). Four scenarios are presented for comparing TEST ("second entry" or "generic") versus REF ("innovator"): (1) innovator and second entry product pMDI alone without any S/VHC (baseline comparison); (2) innovator and second entry pMDI product with the same S/VHC; (3) innovator pMDI product with existing S/VHC and second entry product with a different S/VHC; and (4) introduction of a second, different S/VHC to be used with a given innovator pMDI product. The following aspects should be reviewed in the preparatory stage of designing experiments to establish IVBE: (a) the inclusion of delayed inhalation; (b) the utilization of age-appropriate flow rates; and (c) the use of anatomically appropriate face models for evaluation of devices with a facemask. Statistical considerations that fit in with such experimental methods include: selection of pMDI batches and S/VHC lots; choice of sample size and acceptance criteria; bracketing or worst case approaches; and balanced/paired designs. A stepwise approach for selection of impactor stage groupings is presented, and an approach to determine realistic acceptance criteria based on REF product characteristics is suggested. An example of an efficient statistical design of experiment is provided for each scenario, together with alternate approaches for calculation of confidence intervals for the mean TEST/REF relationship. It is important to appreciate that the optimal design depends on balancing numerous considerations and will thus likely differ from case to case; hence, the designs presented here should be seen as illustrations rather than the only option available. More effective approaches may be found that suit a particular case at hand. The information provided will assist in

  7. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  8. [Bioconstruction of the human ileocaecal valve (author's transl)].

    Science.gov (United States)

    Börner, C; Lierse, W; Schreiber, H W

    1981-01-01

    The lips of the ileocaecal valve are permanent folds parallel to the long axis of the small intestine, which are formed by invagination of all layers of the terminal ileum into the caecum. In the basal two-thirds they contain processes of all muscular layers of ileum and caecum, which form a system of muscle bundles that is connected with the tunica muscularis mucosae. The luminal part of the lips contains a venous plexus embedded in the loose plexus of the tunica mucosa. Arteriovenous anastomoses facilitate the rapid filling of these venous plexus. The ileocaecal valve in humans acts as a combined angiomuscular-angioplical lock-system that under normal conditions prohibits a caeco-ideal reflux.

  9. Ventriculopleural shunting with new technology valves.

    Science.gov (United States)

    Martínez-Lage, J F; Torres, J; Campillo, H; Sanchez-del-Rincón, I; Bueno, F; Zambudio, G; Poza, M

    2000-12-01

    Ventriculoperitoneal shunting constitutes the standard procedure for draining cerebrospinal fluid (CSF) in children with hydrocephalus. Ventriculoatrial and ventriculopleural shunting are alternative methods of CSF drainage, which have gained less acceptance. Ventriculopleural shunts are seldom used owing to justified fears of pneumothorax and symptomatic effusions of CSF. The addition of an antisiphon device to standard shunt systems seems to have prevented CSF pleural effusion. From 1988 to 1998, we treated each of six hydrocephalic children with a ventriculopleural shunt. In five cases we used new-technology valves designed to prevent the effects of siphoning with current differential pressure valves. Peritoneal adhesions, recent peritonitis, ascites, and obstruction of a previous ventriculoatrial shunt were the indications for pleural shunting. After a mean follow-up period of 2.5 years all shunts were functioning adequately. Only one patient showed transient symptoms of CSF overdrainage, which were corrected by up-grading the valve setting with the magnet. A late death was unrelated to the pleural shunting procedure. The use of valves of a new design designed to prevent overdrainage seems to account for the satisfactory outcomes observed in this series. We suggest that ventriculopleural shunting should be considered as the preferred alternative to peritoneal drainage in children with intra-abdominal adhesions or with a history of recent peritoneal infection.

  10. Building valve amplifiers

    CERN Document Server

    Jones, Morgan

    2013-01-01

    Building Valve Amplifiers is a unique hands-on guide for anyone working with tube audio equipment--as an electronics hobbyist, audiophile or audio engineer. This 2nd Edition builds on the success of the first with technology and technique revisions throughout and, significantly, a major new self-build project, worked through step-by-step, which puts into practice the principles and techniques introduced throughout the book. Particular attention has been paid to answering questions commonly asked by newcomers to the world of the valve, whether audio enthusiasts tackling their first build or

  11. Danfos: Thermostatic Radiator Valves

    DEFF Research Database (Denmark)

    Gregersen, Niels; Oliver, James; Hjorth, Poul G.

    2000-01-01

    This problem deals with modelling the flow through a typical Danfoss thermostatic radiator valve.Danfoss is able to employ Computational Fluid Dynamics (CFD) in calculations of the capacity of valves, but an experienced engineer can often by rules of thumb "guess" the capacity, with a precision...... similar to the one achieved by the expensive and time-consuming CFD calculations. So CFD is only used in case of entirely new designs or where a very detailed knowledge of the flow is required. Even though rules of thumb are useful for those, who have developed them, Danfoss needs an objective and general...

  12. SAFETY SHUTOFF VALVE

    DEFF Research Database (Denmark)

    2010-01-01

    resulted from collision or effusion. A static tower has been applied for the main core of this part of the valve which loses balance state under the effect of collision and bounces to the neighboring part, which results in release of the catch and blockage of the gas passing channel.......It is disclosed a shut-off valve which acts automatically and has a fully mechanical performance with respect to the loosing of the tower-shape part balance under the effect of the special acceleration Which is arisen from the quakes waves or serious vibrations, while such vibrations are mainly...

  13. Edwards SAPIEN 3 valve.

    Science.gov (United States)

    Binder, Ronald K; Rodés-Cabau, Josep; Wood, David A; Webb, John G

    2012-09-01

    Building on the established success with the SAPIEN, SAPIEN XT and earlier prototypic transcatheter heart valves (THV) the newest balloon-expandable valve incorporates a number of new and enhanced features intended to reduce the risk of vascular injury, to reduce paravalvular regurgitation, and to facilitate rapid and accurate positioning and implantation. The SAPIEN 3 THV incorporates a cobalt chromium stent, bovine pericardial leaflets, and both an inner and new outer polyethylene terephthalate sealing cuff. The delivery system incorporates an active three-dimensional coaxial positioning catheter, and is compatible with a 14 Fr expandable sheath.

  14. Development of an Electronically Controlled Self-Teaching Lift Valve Family

    OpenAIRE

    Goenechea, Eneko

    2016-01-01

    Other than mobile hydraulics and high voltage switchgears, Bucher Hydraulics is also involved in the less-known area of hydraulic lifts. In fact, Bucher Hydraulics did invent the electronically controlled lift valve in the 1970s. Since then, Bucher Hydraulics developed a wide line of products for hydraulic elevators, such as valves and power units. In 2012, this valve family included various sizes, pressure ranges, systems with constant motor speeds, inverter-driven motors, energy-efficient s...

  15. Fluid and Structural Analysis of Large Butterfly Valve

    Science.gov (United States)

    Song, Xueguan; Wang, Lin; Park, Youngchul

    2008-10-01

    A butterfly valve of large diameter is commonly used as control equipments in applications where the inlet velocity is fast and the pressure is relatively high. Because of the size of the valve is too large, therefore it's too difficult to conduct the experiment in a laboratory. In this paper, the numerical simulation using commercial package-CFX and ANSYS was conducted. In order to do fluid analysis and structural analysis perfectly, large valve models are generated in three dimensions without much simplification, the result of fluid analysis is also fully coupled to the structural domain by the fluid-structural interface to provide an exacter initial condition. In addition to describe the flow patterns and to measure the performance coefficients when the valves with various open angles were used, the verification of the safety performance whether the valve could work normally at those conditions or not was conducted. Fortunately, the result shows this type valve is safe in a given inlet velocity of 3m/s, and it's not necessary to be strengthened anywhere, and if need be, the shape of valve disc can be optimized to reduce the weight of disc, and also to make the flow coefficient be closer to the suggested level.

  16. A novel mechanical mitral valve replacement using Sapien XT.

    Science.gov (United States)

    Koehle, Megan; Strote, Justin A; Guadagnoli, Mark; Oldemeyer, J Bradley

    2017-06-09

    We report the case of a 66 year old female who presented to our institution fourteen years after receiving a St. Jude Mechanical Mitral Valve Replacement. She presented in refractory NYHA class IV congestive heart failure with comorbidities of acute renal failure, liver failure, and mental status changes. She was found to have immobility of one of the mitral valve disks with resultant severe mitral stenosis with a mean pressure gradient of 12 mmHg. The patient was found to have an STS predicted mortality of 39% with redo surgical MVR, and evaluation by the valve team led to a recommendation of a hybrid surgical and transcatheter procedure. The patient underwent femoral bypass and hypothermia with a sternotomy and left atrial approach. The mechanical discs were removed utilizing needle drivers without removal of the St. Jude ring. Subsequently, a 26 mm Edwards Sapien XT valve was deployed under direct and fluoroscopic visualization. The patient had an event free post-operative course, and one year following the procedure has had an outstanding clinical response with NYHA class II congestive heart failure. Her echocardiogram reveals normal valve function with a MPG of 4 mmHg without mitral regurgitation. Transatrial hybrid TMVR within the ring of a St. Jude mechanical mitral valve appears to be a feasible procedure which may be used in the future to decrease morbidity and mortality associated with high-risk redo-MVR in patients with mechanical mitral valve prostheses. © 2017 Wiley Periodicals, Inc.

  17. 49 CFR 236.768 - Locking, time.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, time. 236.768 Section 236.768... Locking, time. A method of locking, either mechanical or electrical, which, after a signal has been caused to display an aspect to proceed, prevents, until after the expiration of a predetermined time...

  18. 49 CFR 236.105 - Electric lock.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Electric lock. 236.105 Section 236.105 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION...: All Systems Inspections and Tests; All Systems § 236.105 Electric lock. Electric lock, except forced...

  19. 49 CFR 236.761 - Locking, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, electric. 236.761 Section 236.761 Transportation Other Regulations Relating to Transportation (Continued) FEDERAL RAILROAD ADMINISTRATION... Locking, electric. The combination of one or more electric locks and controlling circuits by means of...

  20. 49 CFR 236.757 - Lock, electric.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Lock, electric. 236.757 Section 236.757... Lock, electric. A device to prevent or restrict the movement of a lever, a switch or a movable bridge, unless the locking member is withdrawn by an electrical device, such as an electromagnet, solenoid or...

  1. Bilateral locked facets in the thoracic spine

    NARCIS (Netherlands)

    M.H.A. Willems; Braakman, R. (Reinder); B. van Linge (Bert)

    1984-01-01

    textabstractTwo cases of traumatic bilateral locked facets in the thoracic spine are reported. Both patients had only minor neurological signs. They both made a full neurological recovery after surgical reduction of the locked facets. Bilateral locked facets are very uncommon in the thoracic spine.

  2. 46 CFR 108.157 - Locked doors.

    Science.gov (United States)

    2010-10-01

    ... may be designed to lock except— (a) A crash door or a door that has a locking device that can be... GUARD, DEPARTMENT OF HOMELAND SECURITY (CONTINUED) A-MOBILE OFFSHORE DRILLING UNITS DESIGN AND EQUIPMENT... has control of the key to the door's lock. ...

  3. Locked jaw in polymyalgia rheumatica.

    Science.gov (United States)

    Lim, S H; McLeay, G

    1988-02-01

    Polymyalgia rheumatica is a common disease affecting the elderly population. Symptoms and signs are often nonspecific, including pain and stiffness in the proximal muscles, anorexia, fatigue, depression, weight loss, fever and temporal headaches. We would like to report a case of polymyalgia rheumatica with locked jaw, a feature yet unrecorded.

  4. Advances phase-lock techniques

    CERN Document Server

    Crawford, James A

    2008-01-01

    From cellphones to micrprocessors, to GPS navigation, phase-lock techniques are utilized in most all modern electronic devices. This high-level book takes a systems-level perspective, rather than circuit-level, which differentiates it from other books in the field.

  5. 49 CFR 236.766 - Locking, movable bridge.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Locking, movable bridge. 236.766 Section 236.766... Locking, movable bridge. The rail locks, bridge locks, bolt locks, circuit controllers, and electric locks used in providing interlocking protection at a movable bridge. ...

  6. The Neopuff's PEEP valve is flow sensitive.

    LENUS (Irish Health Repository)

    Hawkes, Colin Patrick

    2012-01-31

    AIM: The current recommendation in setting up the Neopuff is to use a gas flow of 5-15 L\\/min. We investigated if the sensitivity of the positive end expiratory pressure (PEEP) valve varies at different flow rates within this range. METHODS: Five Neopuffs were set up to provide a PEEP of 5 cm H(2) O. The number of clockwise revolutions to complete occlusion of the PEEP valve and the mean and range of pressures at each quarter clockwise revolution were recorded at gas flow rates between 5 and 15 L\\/min. Results: At 5, 10 and 15 L\\/min, 0.5, 1.7 and 3.4 full clockwise rotations were required to completely occlude the PEEP valve, and pressures rose from 5 to 11.4, 18.4 and 21.5 cm H(2) O, respectively. At a flow rate of 5 L\\/min, half a rotation of the PEEP dial resulted in a rise in PEEP from 5 to 11.4cm H(2) O. At 10 L\\/min, half a rotation resulted in a rise from 5 to 7.7cm H(2) O, and at 15 L\\/min PEEP rose from 5 to 6.8cm H(2) O. CONCLUSION: Users of the Neopuff should be aware that the PEEP valve is more sensitive at lower flow rates and that half a rotation of the dial at 5 L\\/min gas flow can more than double the PEEP.

  7. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-10-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  8. Tidal locking of habitable exoplanets

    Science.gov (United States)

    Barnes, Rory

    2017-12-01

    Potentially habitable planets can orbit close enough to their host star that the differential gravity across their diameters can produce an elongated shape. Frictional forces inside the planet prevent the bulges from aligning perfectly with the host star and result in torques that alter the planet's rotational angular momentum. Eventually the tidal torques fix the rotation rate at a specific frequency, a process called tidal locking. Tidally locked planets on circular orbits will rotate synchronously, but those on eccentric orbits will either librate or rotate super-synchronously. Although these features of tidal theory are well known, a systematic survey of the rotational evolution of potentially habitable exoplanets using classic equilibrium tide theories has not been undertaken. I calculate how habitable planets evolve under two commonly used models and find, for example, that one model predicts that the Earth's rotation rate would have synchronized after 4.5 Gyr if its initial rotation period was 3 days, it had no satellites, and it always maintained the modern Earth's tidal properties. Lower mass stellar hosts will induce stronger tidal effects on potentially habitable planets, and tidal locking is possible for most planets in the habitable zones of GKM dwarf stars. For fast-rotating planets, both models predict eccentricity growth and that circularization can only occur once the rotational frequency is similar to the orbital frequency. The orbits of potentially habitable planets of very late M dwarfs ([InlineEquation not available: see fulltext.]) are very likely to be circularized within 1 Gyr, and hence, those planets will be synchronous rotators. Proxima b is almost assuredly tidally locked, but its orbit may not have circularized yet, so the planet could be rotating super-synchronously today. The evolution of the isolated and potentially habitable Kepler planet candidates is computed and about half could be tidally locked. Finally, projected TESS planets

  9. Overview of Prevention for Water Hammer by Check Valve Action in Nuclear Reactor

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Dayong; Yoon, Hyungi; Seo, Kyoungwoo; Kim, Seonhoon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    Water hammer can cause serious damage to pumping system and unexpected system pressure rise in the pipeline. In nuclear reactor, water hammer can influence on the integrity of safety related system. Water hammer in nuclear reactor have been caused by voiding in normally water-filled lines, steam condensation line containing both steam and water, as well as by rapid check valve action. Therefore, this study focuses on the water hammer by check valve among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. This study focuses on the water hammer by check valve action among the sources of water hammer occurrence and suggests proper methodology for check valve type selection against water hammer. If the inadvertent pump trip or pipe rupture in high velocity and pressure pipe is predicted, the fast response check valve such as tiled disc, dual disc and nozzle check valve should be installed in the system. If the inadvertent pump trip or pipe rupture in very high velocity and pressure pipe and excessively large revered flow velocity are predicted, the very slowly closing check valve such as controlled closure check valve should be installed in the system.

  10. Flow characteristics past jellyfish and St. Vincent valves in the aortic position under physiological pulsatile flow conditions.

    Science.gov (United States)

    Morsi, Y S; Sakhaeimanesh, A A

    2000-07-01

    Thrombus formation and hemolysis have been linked to the dynamic flow characteristics of heart valve prostheses. To enhance our understanding of the flow characteristics past the aortic position of a Jellyfish (JF) valve in the left ventricle, in vitro laser Doppler anemometry (LDA) measurements were carried out under physiological pulsatile flow conditions. The hemodynamic performance of the JF valve was then compared with that of the St. Vincent (SV) valve. The comparison was given in terms of mean systolic pressure drop, back flow energy losses, flow velocity, and shear stresses at various locations downstream of both valves and at cardiac outputs of 3.5 L/min, 4.5 L/min, and 6.5 L/min respectively. The results indicated that both valves created disturbed flow fields with elevated levels of turbulent shear stress as well as higher levels of turbulence in the immediate vicinity of the valve and up to 1 diameter of the pipe (D) downstream of the valve. At a location further downstream, the JF valve showed better flow characteristics than the SV in terms of velocity profiles and turbulent shear stresses. The closure volume of the SV valve was found to be 2.5 times higher than that of the JF valve. Moreover, the total back flow losses and mean systolic pressure drop also were found to be higher in the SV than the JF valve.

  11. Performance of different PEEP valves and helmet outlets at increasing gas flow rates: a bench top study.

    Science.gov (United States)

    Isgrò, S; Zanella, A; Giani, M; Abd El Aziz El Sayed Deab, S; Pesenti, A; Patroniti, N

    2012-10-01

    Aim of the paper was to assess the performance of different expiratory valves and the resistance of helmet outlet ports at increasing gas flow rates. A gas flow-meter was connected to 10 different expiratory peep valves: 1 water-seal valve, 4 precalibrated fixed PEEP valves and 5 adjustable PEEP valves. Three new valves of each brand, set at different pressure levels (5-7.5-10-12.5-15 cmH(2)O, if available), were tested at increasing gas flow rates (from 30 to 150 L/min). We measured the pressure generated just before the valves. Three different helmets sealed on a mock head were connected at the inlet port with a gas flow-meter while the outlet was left clear. We measured the pressure generated inside the helmet (due to the flow-resistance of the outlet port) at increasing gas flow rates. Adjustable valves showed a variable degree flow-dependency (increasing difference between the measured and the expected pressure at increasing flow rates), while pre-calibrated valves revealed a flow-independent behavior. Water seal valve showed low degree flow-dependency. The pressures generated by the outlet port of the tested helmets ranged from 0.02 to 2.29 cmH(2)O at the highest gas flow rate. Adjustable PEEP valves are not suggested for continuous-flow CPAP systems as their flow-dependency can lead to pressures higher than expected. Precalibrated and water seal valves exhibit the best performance. Different helmet outlet ports do not significantly affect the pressure generated during helmet CPAP. In order to avoid iatrogenic complications gas flow and pressure delivered during helmet CPAP must always be monitored.

  12. Unsteady Analyses of Valve Systems in Rocket Engine Testing Environments

    Science.gov (United States)

    Shipman, Jeremy; Hosangadi, Ashvin; Ahuja, Vineet

    2004-01-01

    This paper discusses simulation technology used to support the testing of rocket propulsion systems by performing high fidelity analyses of feed system components. A generalized multi-element framework has been used to perform simulations of control valve systems. This framework provides the flexibility to resolve the structural and functional complexities typically associated with valve-based high pressure feed systems that are difficult to deal with using traditional Computational Fluid Dynamics (CFD) methods. In order to validate this framework for control valve systems, results are presented for simulations of a cryogenic control valve at various plug settings and compared to both experimental data and simulation results obtained at NASA Stennis Space Center. A detailed unsteady analysis has also been performed for a pressure regulator type control valve used to support rocket engine and component testing at Stennis Space Center. The transient simulation captures the onset of a modal instability that has been observed in the operation of the valve. A discussion of the flow physics responsible for the instability and a prediction of the dominant modes associated with the fluctuations is presented.

  13. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, Jordan [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States); Ansanelli, Eric [Advanced Residential Integrated Energy Solutions Collaborative, New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market.

  14. Aortic valve surgery - open

    Science.gov (United States)

    ... be able to store blood in the blood bank for transfusions during and after your surgery. Ask ... Mechanical heart valves do not fail often. However, blood clots can develop on them. If a blood clot forms, you may have a stroke. Bleeding can occur, ...

  15. Dynamic Characteristics Analysis of Power Shift Control Valve

    Directory of Open Access Journals (Sweden)

    Feng Ren

    2014-07-01

    Full Text Available In order to study the influence that dynamic performance of shift control valve has on shifting process of construction machinery, the paper introduces working principle of the shift control valve and sets up the dynamically mathematical model and corresponding simulation model with simulation software LMS Imagine. Lab AMESim. Based on simulation, the paper analyzes the influence of pressure variation characteristics and buffering characteristics acting on vehicle performance during the process of shifting, meanwhile conducting experiments to verify the simulation. The results indicate that the simulation model is accurate and credible; the performance of the valve is satisfactory, which indeed reduces impact during shifting. Furthermore, the valve can meet the demand of other construction machineries in better degree by suitable matching between control spring stiffness and damping holes diameter.

  16. Measurement of reed valve kinematics

    Directory of Open Access Journals (Sweden)

    Fenkl Michael

    2016-01-01

    Full Text Available The measurement of key kinematic parameters of a reed valve movement is necessary for the further development of the reed valve system. These parameters are dependent on the geometry and material properties of the valve. As they directly affect the quantity of air flowing around the valve, a simple and easy to implement measurement of various valve configuration based on the air flow has been devised and is described in this paper, along with its technical parameters and drawbacks when evaluating reed valves used in reciprocating air compressors. Results are presented for a specimen of a compressor under examination. All kinematic parameters, and timing of the opening and closing of the valve, obtained from the measurement are presented and discussed.

  17. Design Optimization of Moving Magnet Actuated Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Madsen, Esben Lundø; Nørgård, Christian; Bech, Michael Møller

    2017-01-01

    optimized design closes in 2.1 ms, has a pressure drop of 0.8 bar at 150 l/min and yields a digital displacement machine average chamber efficiency of 98.9%. The design is simple in construction and uses a single coil, positioned outside the pressure chamber, eliminating the need for an electrical interface......High-efficiency hydraulic machines using digital valves are presently a topic of great focus. Digital valve performance with respect to pressure loss, closing time as well as electrical power consumption, is key to obtaining high efficiency. A recent digital seat valve design developed at Aalborg...

  18. Protocol for Relative Hydrodynamic Assessment of Tri-leaflet Polymer Valves

    Science.gov (United States)

    Ramaswamy, Sharan; Salinas, Manuel; Carrol, Rob; Landaburo, Karla; Ryans, Xavier; Crespo, Cynthia; Rivero, Ailyn; Al-Mousily, Faris; DeGroff, Curt; Bleiweis, Mark; Yamaguchi, Hitomi

    2013-01-01

    Limitations of currently available prosthetic valves, xenografts, and homografts have prompted a recent resurgence of developments in the area of tri-leaflet polymer valve prostheses. However, identification of a protocol for initial assessment of polymer valve hydrodynamic functionality is paramount during the early stages of the design process. Traditional in vitro pulse duplicator systems are not configured to accommodate flexible tri-leaflet materials; in addition, assessment of polymer valve functionality needs to be made in a relative context to native and prosthetic heart valves under identical test conditions so that variability in measurements from different instruments can be avoided. Accordingly, we conducted hydrodynamic assessment of i) native (n = 4, mean diameter, D = 20 mm), ii) bi-leaflet mechanical (n= 2, D = 23 mm) and iii) polymer valves (n = 5, D = 22 mm) via the use of a commercially available pulse duplicator system (ViVitro Labs Inc, Victoria, BC) that was modified to accommodate tri-leaflet valve geometries. Tri-leaflet silicone valves developed at the University of Florida comprised the polymer valve group. A mixture in the ratio of 35:65 glycerin to water was used to mimic blood physical properties. Instantaneous flow rate was measured at the interface of the left ventricle and aortic units while pressure was recorded at the ventricular and aortic positions. Bi-leaflet and native valve data from the literature was used to validate flow and pressure readings. The following hydrodynamic metrics were reported: forward flow pressure drop, aortic root mean square forward flow rate, aortic closing, leakage and regurgitant volume, transaortic closing, leakage, and total energy losses. Representative results indicated that hydrodynamic metrics from the three valve groups could be successfully obtained by incorporating a custom-built assembly into a commercially available pulse duplicator system and subsequently, objectively compared to provide

  19. Micro-valve pump light valve display

    Science.gov (United States)

    Lee, Yee-Chun

    1993-01-01

    A flat panel display incorporates a plurality of micro-pump light valves (MLV's) to form pixels for recreating an image. Each MLV consists of a dielectric drop sandwiched between substrates, at least one of which is transparent, a holding electrode for maintaining the drop outside a viewing area, and a switching electrode from accelerating the drop from a location within the holding electrode to a location within the viewing area. The sustrates may further define non-wetting surface areas to create potential energy barriers to assist in controlling movement of the drop. The forces acting on the drop are quadratic in nature to provide a nonlinear response for increased image contrast. A crossed electrode structure can be used to activate the pixels whereby a large flat panel display is formed without active driver components at each pixel.

  20. Curved butterfly bileaflet prosthetic cardiac valve

    Energy Technology Data Exchange (ETDEWEB)

    McQueen, D.M.; Peskin, C.S.

    1991-06-25

    An annular valve body having a central passageway for the flow of blood with two curved leaflets is described. Each of the leaflets is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance. 26 figures.

  1. Curved butterfly bileaflet prosthetic cardiac valve

    Energy Technology Data Exchange (ETDEWEB)

    McQueen, David M. (185 Hillside Ave., Chatham, NJ 07928); Peskin, Charles S. (186 Harrard Dr., Hartsdale, NY 10530)

    1991-06-25

    An annular valve body having a central passageway for the flow of blood therethrough with two curved leaflets each of which is pivotally supported on an accentric positioned axis in the central passageway for moving between a closed position and an open position. The leaflets are curved in a plane normal to the eccentric axis and positioned with the convex side of the leaflets facing each other when the leaflets are in the open position. Various parameters such as the curvature of the leaflets, the location of the eccentric axis, and the maximum opening angle of the leaflets are optimized according to the following performance criteria: maximize the minimum peak velocity through the valve, maximize the net stroke volume, and minimize the mean forward pressure difference, thereby reducing thrombosis and improving the hemodynamic performance.

  2. First in human implantation of the mechanical expanding Lotus® valve in degenerated surgical valves in mitral position.

    Science.gov (United States)

    Schaefer, Ulrich; Conradi, Lenard; Lubos, Edith; Deuschl, Florian; Schofer, Niklas; Seiffert, Moritz; Treede, Hendrik; Schirmer, Johannes; Reichenspurner, Hermann; Blankenberg, Stefan

    2015-12-01

    Implantation of transcatheter heart valves (THV) into degenerated surgical valves is an emerging therapy for selected high-risk patients. Although, CE mark of most THV is limited for native aortic valvular stenosis, transcatheter valve implantation into degenerated bioprostheses, even in mitral position is very intriguing. After placement of a cerebral protection device (Claret Sentinel®), three consecutive patients (age, 79.0 ± 6.1; log EuroSCORE I: 33.3 ± 9.2%) with a degenerated mitral bioprosthesis were treated by transapical implantation of the Lotus® valve (Boston Scientific Inc.). In addition, a SwanGanz catheter was introduced in the pulmonary artery for hemodynamic assessments all patients. Procedural success was 100%. Valve implantation was performed without rapid ventricular pacing. Resheating was performed in two patients due to suboptimal initial positioning. Invasive online hemodynamics revealed stable blood pressure in all patients. After Lotus® valve implantation, valvular mitral regurgitation was completely eliminated in all patients. One patient had a mild paravalvular leak of the surgical bioprosthesis, which was present before implantation. Invasive right and left heart hemodynamics showed an immediate improvement after Lotus® valve implantation. Mean mitral surface area (2.1 ± 0.2 cm(2) ) and mean gradient (3.7 ± 2.1 mm Hg) demonstrated satisfactory results. All patients were immediately extubated and discharged from the hospital without any adverse event. This study demonstrates for the first time the feasibility of transapical Lotus® Valve implantation in degenerated mitral bioprostheses. The controlled mechanical Lotus® valve expansion with remarkably stable hemodynamics throughout the procedure offers a new and valuable treatment option. © 2015 Wiley Periodicals, Inc.

  3. Valve applications at the SYNTHANE Plant in mixed phase erosive service

    Energy Technology Data Exchange (ETDEWEB)

    Bailey, D.M.; Massa, A.W.; Runnels, O.D.; Strebinger, P.C.; Lummus, C.E.

    1977-11-01

    Three different control valves used for depressuring abrasive, high-pressure process streams containing coal fines have been improved by upgrading their trim materials. Original trims were of ceramic or of stainless steel coated with stellite; upgraded trims are tungsten carbide. The new materials have significantly improved valve life. These valves are in operation at the SYNTHANE Pilot Plant, a high BTU coal gasification facility operated for the Department of Energy by the Lummus Company. The Plant has been in operation since July of 1976. To date more than 2000 tons of coal have been gasified and these valves have been subjected to nearly 1000 hours of operation.

  4. Jaw locking after maxillofacial trauma

    Directory of Open Access Journals (Sweden)

    David B. Kamadjaja

    2007-09-01

    Full Text Available The purpose of this report is to present two cases of jaw locking with two different etiologies. In case #1, jaw locking occured 5.5 months after a surgical reduction and internal fixation on the fractured maxilla and mandible. Some plain radiographic x-ray were made but failed to give adequate information in establishing the cause of trismus. The three dimensional computed tomography (3D-CT was finally made and able to help guide the pre-operative diagnosis and treatment. Two-steps gap arthroplasty were done comprising a gap arthroplasty leading to acceptable outcome. An adult patient in case #2 with a history of trauma at his childhood and bird-like face apprearance clinically, was unable to open the mouth since the time of accident. The patient was diagnosed with bilateral ankylosis of temporomandibular joints. One side (right gap arthroplasty was done and resulted in normal mouth opening.

  5. Locking devise for oil platforms

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, P.-A.; Naudin, J.-C.

    1987-10-20

    A self-raising oil well platform comprises a shell mounted to be movable along legs by means of raising mechanisms comprising output gear pinions cooperative with racks mounted on at least a part of the length of the legs. The locking device for such a platform comprises a toothed member forming a counter-rack mounted on the shell of the platform, means for shifting the toothed member transversely of the direction of the rack with which the device is associated for engaging or disengaging the teeth of the toothed member in the teeth of the rack, clamping plates connected to the toothed member and clamping counter-plates connected to the platform, and means for clamping the plates and counter-plates together so as to lock the toothed member in position in the rack. 4 figs.

  6. First Reported Successful Femoral Valve-in-Valve Transcatheter Aortic Valve Replacement Using the Edwards Sapien 3 Valve.

    Science.gov (United States)

    Fournier, Stephane; Monney, Pierre; Roguelov, Christan; Zuffi, Andrea; Iglesias, Juan F; Qanadli, Salah D; Courbon, Cecile; Eeckhout, Eric; Muller, Olivier

    2015-10-01

    Management of degenerated aortic valve bioprosthesis classically requires redo surgery, but transcatheter aortic valve-in-valve implantation is becoming a valid alternative in selected cases. In the case of a degenerated Mitroflow bioprosthesis, TAVR is associated with an additional challenge due to a specific risk of coronary occlusion. We aimed to assess the safety and feasibility of transfemoral valve-in-valve implantation of the new Edwards Sapien 3 (Edwards Lifesciences) in a degenerated Mitroflow bioprosthesis (Sorin Group, Inc). We report here the safety and feasibility of transfemoral valve-in-valve implantation of a 23 mm Edwards Sapien 3 in a degenerated 25 mm Mitroflow valve and describe the specific assessment of the risk of coronary obstruction using a multi-imaging modality. The final result showed an absence of aortic regurgitation and a mean transvalvular gradient of 14 mm Hg. The patient had no major adverse cardiovascular events at 30-day follow-up. Transcatheter valve-in-valve implantation of an Edwards Sapien 3 in a degenerated Mitroflow is feasible and safe, considering a careful assessment of the risk of coronary obstruction with Mitroflow bioprosthesis due to leaflets mounted externally to the stent.

  7. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-02-01

    Full Text Available Aim: Valve diseases in developing countries like Turkey which often occur as a complication of rheumatic fever are a serious disease. Surgical treatment of valve diseases should be done before irreversible damage to the myocardium occurred. In this study, we aimed to present the early results of mechanical valve replacement operations. Method: A hundred patients with mechanical valve replacement surgery were retrospectively evaluated in Seyhan Application Center attached to our clinic between July 2007 and August 2011. Results: Fifty patients were male and 50 were women. The mean age of patients was 47.88 (18-78. Isolated aortic valve replacement (AVR was performed to 23 patients, isolated mitral valve replacement (MVR was 32, double valve replacement (AVR + MVR was 12, MVR + aortic valve valvuloplasty was 1, AVR + mitral kommissurotomi was 1, AVR + coronary artery bypass graft surgery (CABG was 17, MVR + CABG was 8, MVR + atrial septal defect closure was 2 and Bentall procedure.was 4 patients. In addition, ablation procedure was performed to 5 patients intraoperatively because of preoperative atrial fibrillation. Two patients (2 % died in early postoperative period. Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1.000: 49-54

  8. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  9. Performance Characteristics of an Isothermal Freeze Valve

    Energy Technology Data Exchange (ETDEWEB)

    Hailey, A.E.

    2001-08-22

    This document discusses performance characteristics of an isothermal freeze valve. A freeze valve has been specified for draining the DWPF melter at the end of its lifetime. Two freeze valve designs have been evaluated on the Small Cylindrical Melter-2 (SCM-2). In order to size the DWPF freeze valve, the basic principles governing freeze valve behavior need to be identified and understood.

  10. Tricuspid Valve Replacement, Mechnical vs. Biological Valve, Which Is Better?

    Directory of Open Access Journals (Sweden)

    Haitham Akram Altaani

    2013-06-01

    Full Text Available Background: The initial trial in tricuspid surgery is repair; however, replacement is done whenever the valve is badly diseased. Tricuspid valve replacement comprises 1.7% of all tricuspid valve surgeries. Materials and Methods: The present retrospective study was performed using the medical records of 21 cases who underwent tricuspid valve replacement from January 2002 until the end of December 2010. The mean age of the participants was 52.3±8.8 years and 66.7% were females. In addition, tricuspid valve replacement was associated with mitral valve surgery, aortic valve surgery, and both in 14.3%, 4.8%, and 33.3% of the cases, respectively. Yet, isolated tricuspid valve replacement and redo surgery were performed in 10 cases (47.6% and 8 cases (38.1%, respectively. Besides, trial of repair was done in 14 cases (66.7%. Moreover, biological and mechanical valves were used in 76.2% and 23.8% of the patients, respectively. Results: According to the results, early mortality was 23.8% and one year survival was 66.7%. Moreover, early mortality was caused by right ventricular failure, multiorgan failure, medistinitis, and intracerbral bleeding in 42%, 28.6%, 14.3%, and 14.3% of the cases, respectively. In addition, 57.1% of the deaths had occurred in the cases where the biological valve was used, while 42.9% of the deaths had taken place where the mechanical one was utilized. Conclusions: The patients who require tricuspid valve replacement are usually high risk surgical candidates with early and long term mortality. The findings of the current study showed no significant hemodynamic difference between mechanical and biological valves.

  11. New Seat Design and Finite Element Analysis for Anti-Leakage of Globe Valve

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sung Ho [Sunlin College, Pohang (Korea, Republic of); Kang, Gyeong Ah; Kwak, Jae Seob; An, Jun Eun; Jin, Dong Hyun [Pukyong National Univ., Daejeon (Korea, Republic of)

    2016-01-15

    The valves used to control or shut off the flow through a pipeline can be divided into many different types, including gate valves, globe valves, and check valves. Globe valves, in particular, have excellent properties, and because they can easily control the flow under high-pressure conditions, they are generally used in LNG ship and steam pipelines. In this paper, a method for changing the shape of a seat was suggested to solve the valve leakage problem from a structural perspective. In addition, the stress distribution and directional deformation were compared for each model. The suggested models were thus validated, and the optimized seat structure, which includes a self-supporting capability for decreasing the amount of leakage, was determined.

  12. Transapical off-pump removal of the native aortic valve: a proof-of-concept animal study.

    Science.gov (United States)

    Salizzoni, Stefano; Bajona, Pietro; Zehr, Kenton J; Anderson, William D; Vandenberghe, Stijn; Speziali, Giovanni

    2009-08-01

    This study evaluates the feasibility of off-pump native aortic valve removal in preparation for transapical aortic valve replacement. Off-pump aortic valve replacement is performed by balloon predilatation of the native valve followed by insertion of a stented prosthesis. In patients with calcified annuli and cusps, particulate embolization, suboptimal prosthesis sizing, and perivalvular leaks may occur. Therefore, native valve removal may improve outcomes after transapical aortic valve replacement. The aortic cusps were sequentially removed from 10 pigs in an off-pump procedure. A temporary valve was inserted percutaneously into the ascending aorta to prevent aortic regurgitation. The electrocardiogram, coronary blood flow, and arterial, left atrial, and ventricular pressures were continuously monitored. Removal of the aortic cusps caused a drop in diastolic arterial pressure and its equalization with left ventricular diastolic pressure. Systolic pressure decreased by 13.5%. Left atrial pressure increased by 86.0%. Coronary blood flow decreased by 39.9% and its pattern changed from mostly diastolic to mostly systolic. Electrocardiographic signs of ischemia appeared almost immediately. Percutaneous insertion of a temporary valve in the ascending aorta increased diastolic pressure and caused a tendency toward echocardiographic normalization. Aortic valve removal in a healthy beating heart causes acute massive aortic regurgitation, hemodynamic instability, and the rapid onset of myocardial ischemia. Reduction of left ventricular volume overload, by placement of a temporary valve in the ascending aorta, mitigates myocardial distress, helps stabilize hemodynamic parameters, and may be a useful tool to allow surgical manipulations of the aortic valve and annulus during transapical aortic valve replacement procedures.

  13. Physics and Control of Locked Modes in the DIII-D Tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Volpe, Francesco [Columbia Univ., New York, NY (United States). Dept. of Applied Physics and Applied Mathematics

    2017-01-30

    This Final Technical Report summarizes an investigation, carried out under the auspices of the DOE Early Career Award, of the physics and control of non-rotating magnetic islands (“locked modes”) in tokamak plasmas. Locked modes are one of the main causes of disruptions in present tokamaks, and could be an even bigger concern in ITER, due to its relatively high beta (favoring the formation of Neoclassical Tearing Mode islands) and low rotation (favoring locking). For these reasons, this research had the goal of studying and learning how to control locked modes in the DIII-D National Fusion Facility under ITER-relevant conditions of high pressure and low rotation. Major results included: the first full suppression of locked modes and avoidance of the associated disruptions; the demonstration of error field detection from the interaction between locked modes, applied rotating fields and intrinsic errors; the analysis of a vast database of disruptive locked modes, which led to criteria for disruption prediction and avoidance.

  14. Development of a micro-mechanical valve in a novel glaucoma implant.

    Science.gov (United States)

    Siewert, Stefan; Schultze, Christine; Schmidt, Wolfram; Hinze, Ulf; Chichkov, Boris; Wree, Andreas; Sternberg, Katrin; Allemann, Reto; Guthoff, Rudolf; Schmitz, Klaus-Peter

    2012-10-01

    This paper describes methods for design, manufacturing and characterization of a micro-mechanical valve for a novel glaucoma implant. The implant is designed to drain aqueous humour from the anterior chamber of the eye into the suprachoroidal space in case of an elevated intraocular pressure (IOP). In contrast to any existing glaucoma drainage device (GDD), the valve mechanism is located in the anterior chamber and there, surrounded by aqueous humour, immune to fibrosis induced failure. For the prevention of hypotony the micro-mechanical valve is designed to open if the physiological pressure difference between the anterior chamber and the suprachoroidal space in the range of 0.8 mmHg to 3.7 mmHg is exceeded. In particular the work includes: (i) manufacturing and morphological characterization of polymer tubing, (ii) mechanical material testing as basis for (iii) the design of micro-mechanical valves using finite element analysis (FEA), (iv) manufacturing of microstent prototypes including micro-mechanical valves by femtosecond laser micromachining and (v) the experimental fluid-mechanical characterization of the manufactured microstent prototypes with regard to valve opening pressure. The considered materials polyurethane (PUR) and silicone (SIL) exhibit low elastic modulus and high extensibility. The unique valve design enables a low opening pressure of micro-mechanical valves. An ideal valve design for PUR and SIL with an experimentally determined opening pressure of 2 mmHg and 3.7 mmHg is identified. The presented valve approach is suitable for the inhibition of hypotony as a major limitation of today's GDD and will potentially improve the minimally invasive treatment of glaucoma.

  15. Patents and heart valve surgery--I: mechanical valves.

    Science.gov (United States)

    Cheema, Faisal H; Hussain, Nasir; Kossar, Alexander P; Polvani, Gianluca

    2013-04-01

    Valvular heart disease, inherited or acquired, affects more than 5 million Americans yearly. Whereas medical treatment is beneficial in the initial stages of valvular heart disease, surgical correction provides symptomatic relief and long-term survival benefits. Surgical options include either repair or replacement using mechanical or bio-prosthetic valves. Patient age and the post-operative need for anticoagulation therapy are major determinants of the choice between use of mechanical or bio-prosthetic valves. Since the first mechanical valves were made available several decades ago, the incorporation of increasingly sophisticated materials and methodologies has led to substantial improvements in the valve design, and has catalyzed a parallel increase in the amount of patents issued for these emerging technologies. In this paper, we have chronologically reviewed such patents, briefly discussed various challenges that mechanical heart valve implementation is faced with and finally reviewed some of the strategies employed to overcome such obstacles. An ideal prosthetic heart valve would comprehensively mimic the natural hemodynamics and physiology of the native heart valve. Additionally, such a valve would be easily implantable, associated with a minimal risk of thrombosis and thus need for anti-coagulation, and with a proven long-term durability. With cutting edge technological advancements in the recent times, the ongoing innovative and collaborative efforts of physicians, scientists, and engineers will not seize until an ideal mechanical heart valve becomes a reality.

  16. Aortic valve replacement

    DEFF Research Database (Denmark)

    Kapetanakis, Emmanouil I; Athanasiou, Thanos; Mestres, Carlos A

    2008-01-01

    countries. METHODS: A multi-institutional, non-randomized, retrospective analysis was conducted among 2,932 patients who underwent AVR surgery at seven tertiary cardiac surgery centers throughout Europe. Demographic and perioperative variables including valve size and type, body surface area (BSA) and early...... and southern European countries. Imbalances in the prevalence of rheumatic heart disease, health resource availability and variations in surgical practice throughout Europe might be possible etiological causes....

  17. Aircraft Anti-Skid Brake Control Based on High-Speed on-off Valve

    Directory of Open Access Journals (Sweden)

    Li Wei

    2015-01-01

    Full Text Available Aircraft hydraulic brake system usually use pressure servo valve for anti-skid brake control. As pressure servo valve realizes the pressure closed loop by hydraulic feedback loop, this structure increased the complexity of the processing and manufacturing, restricted the pressure closed loop parameters adjustment, and increased the difficulty of debugging the system design. Pressure servo valve is expensive and difficult to process, poor ability to resist pollution. This paper proposed a slip ratio large closed loop aircraft anti-skid brake control method based on high-speed on-off valve, built the model of aircraft ground vertical taxiing and slip ratio large closed loop control algorithm in the MATLAB/SIMULINK, and built the model of aircraft hydraulic brake system based on on-off valve in the AMESim and a joint simulation was carried out. The simulation results show that the aircraft anti-skid brake control method based on high-speed on-off valve is feasible, and the on-off valve is cheap with strong ability to resist pollution, easy processing and manufacturing and so on, showing a good application prospect.

  18. CLIMATE INSTABILITY ON TIDALLY LOCKED EXOPLANETS

    Energy Technology Data Exchange (ETDEWEB)

    Kite, Edwin S.; Manga, Michael [Department of Earth and Planetary Science, University of California at Berkeley, CA 94720 (United States); Gaidos, Eric, E-mail: edwin.kite@gmail.com [Department of Geology and Geophysics, University of Hawaii at Manoa, Honolulu, HI 96822 (United States)

    2011-12-10

    Feedbacks that can destabilize the climates of synchronously rotating rocky planets may arise on planets with strong day-night surface temperature contrasts. Earth-like habitable planets maintain stable surface liquid water over geologic time. This requires equilibrium between the temperature-dependent rate of greenhouse-gas consumption by weathering, and greenhouse-gas resupply by other processes. Detected small-radius exoplanets, and anticipated M-dwarf habitable-zone rocky planets, are expected to be in synchronous rotation (tidally locked). In this paper, we investigate two hypothetical feedbacks that can destabilize climate on planets in synchronous rotation. (1) If small changes in pressure alter the temperature distribution across a planet's surface such that the weathering rate goes up when the pressure goes down, a runaway positive feedback occurs involving increasing weathering rate near the substellar point, decreasing pressure, and increasing substellar surface temperature. We call this feedback enhanced substellar weathering instability (ESWI). (2) When decreases in pressure increase the fraction of surface area above the melting point (through reduced advective cooling of the substellar point), and the corresponding increase in volume of liquid causes net dissolution of the atmosphere, a further decrease in pressure will occur. This substellar dissolution feedback can also cause a runaway climate shift. We use an idealized energy balance model to map out the conditions under which these instabilities may occur. In this simplified model, the weathering runaway can shrink the habitable zone and cause geologically rapid 10{sup 3}-fold atmospheric pressure shifts within the habitable zone. Mars may have undergone a weathering runaway in the past. Substellar dissolution is usually a negative feedback or weak positive feedback on changes in atmospheric pressure. It can only cause runaway changes for small, deep oceans and highly soluble atmospheric

  19. Anterior Urethral Valves

    Directory of Open Access Journals (Sweden)

    Vidyadhar P. Mali

    2006-07-01

    Full Text Available We studied the clinical presentation and management of four patients with anterior urethral valves; a rare cause of urethral obstruction in male children. One patient presented antenatally with oligohydramnios, bilateral hydronephrosis and bladder thickening suggestive of an infravesical obstruction. Two other patients presented postnatally at 1 and 2 years of age, respectively, with poor stream of urine since birth. The fourth patient presented at 9 years with frequency and dysuria. Diagnosis was established on either micturating cystourethrogram (MCU (in 2 or on cystoscopy (in 2. All patients had cystoscopic ablation of the valves. One patient developed a postablation stricture that was resected with an end-to-end urethroplasty. He had an associated bilateral vesicoureteric junction (VUJ obstruction for which a bilateral ureteric reimplantation was done at the same time. On long-term follow-up, all patients demonstrated a good stream of urine. The renal function is normal. Patients are continent and free of urinary infections. Anterior urethral valves are rare obstructive lesions in male children. The degree of obstruction is variable, and so they may present with mild micturition difficulty or severe obstruction with hydroureteronephrosis and renal impairment. Hence, it is important to evaluate the anterior urethra in any male child with suspected infravesical obstruction. The diagnosis is established by MCU or cystoscopy and the treatment is always surgical, either a transurethral ablation or an open resection. The long-term prognosis is good.

  20. Optothermally actuated capillary burst valve

    Science.gov (United States)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders; Marie, Rodolphe

    2017-04-01

    We demonstrate the optothermal actuation of individual capillary burst valves in an all-polymer microfluidic device. The capillary burst valves are realised in a planar design by introducing a fluidic constriction in a microfluidic channel of constant depth. We show that a capillary burst valve can be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett. 10, 826-832 (2010)]. An individual valve is burst by focusing the laser in its vicinity. We demonstrate the capture of single polystyrene 7 μm beads in the constriction triggered by the bursting of the valve.

  1. Update of transcatheter valve treatment.

    Science.gov (United States)

    Liu, Xian-bao; Wang, Jian-an

    2013-08-01

    Transcatheter valve implantation or repair has been a very promising approach for the treatment of valvular heart diseases since transcatheter aortic valve implantation (TAVI) was successfully performed in 2002. Great achievements have been made in this field (especially TAVI and transcatheter mitral valve repair--MitraClip system) in recent years. Evidence from clinical trials or registry studies has proved that transcatheter valve treatment for valvular heart diseases is safe and effective in surgical high-risk or inoperable patients. As the evidence accumulates, transcatheter valve treatment might be an alterative surgery for younger patients with surgically low or intermediate risk valvular heart diseases in the near future. In this paper, the updates on transcatheter valve treatment are reviewed.

  2. Transapical implantation of a self-expandable aortic valve prosthesis utilizing a novel designed positioning element.

    Science.gov (United States)

    Liu, Xiaopeng; Tang, Yue; Luo, Fuliang; Tian, Yi; Li, Kai; Sun, Jiakang; Jia, Liujun; Wang, Wei

    2017-01-01

    To evaluate a new transapical system which utilizes a novel designed positioning element and a two-step positioning mechanism for easy and accurate implantation of transcatheter valves. Transcatheter aortic valve implantation is an important treatment option for non-surgical patients with severe aortic stenosis. However, accurate placement of the transcatheter valve remains challenging. Self-expandable aortic valve prosthesis with a flexibly connected, annulus-like positioning element was implanted through a transapical approach in 12 pigs. The positioning element was separated and can be released independent of the valve prosthesis. During valve implantation, firstly, the positioning element was unsheathed and fixed into the aortic sinus. Then, the prosthetic valve was guided to an anatomically oriented position and deployed. Six animals were followed up to 180 days. With the help of the positioning element, all 12 valves were successfully deployed at the anticipated site. The valve release procedure took an average of 7.3 ± 2.5 min. The mean transvalvular pressure gradient was 2.8 ± 1.1 mm Hg at valve deployment. Of the six chronic animals, the mean transvalvular pressure gradient was 3.0 ± 1.0 mm Hg on day 7, and 2.9 ± 1.6 mm Hg on day 180 (P = 0.91). No migration, embolization, or coronary obstruction was observed during surgery and at necropsy. Pathological examination showed anatomically correct positioning of the prosthetic valve without signs of thrombosis or calcification. In this study, we confirmed the feasibility of the J-Valve transapical system for transapical implantation through a two-step process. Satisfactory hemodynamic and pathological performance during a follow-up of 180 days was demonstrated. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  3. Qualitative haemodynamic validation of a percutaneous temporary aortic valve: a proof of concept study.

    Science.gov (United States)

    Ho, P C

    2011-02-01

    The concept of temporary aortic valves has been suggested in the clinical settings of acute aortic regurgitation and transcatheter aortic valve replacement procedure (TAVR). In TAVR, suggestions have been made to pre-treat or remove the diseased aortic valve prior to implantation of the replacement valve. A successful temporary aortic valve must demonstrate the ability to prevent life-threatening haemodynamics of massive aortic regurgitation. A novel temporary aortic valve (TAV) design, comprised of inflatable balloon elements as a check-valve, can readily be deployed and retrieved via a catheter-system. A simple flow model is set up to test the TAV's performance in severe aortic regurgitation. With induced aortic regurgitation, placement of the TAV is found to increase the distal aortic diastolic pressure, to reduce the widened pulse pressure, to protect proximal aorta-left ventricle from diastolic pressure elevation and to reduce the aortic regurgitant volume. In conclusion, continued development of the TAV system can lead to a successful temporary aortic valve to be used in various appropriate clinical settings.

  4. Mitral valve repair versus replacement

    Science.gov (United States)

    Keshavamurthy, Suresh; Gillinov, A. Marc

    2015-01-01

    Degenerative, ischemic, rheumatic and infectious (endocarditis) processes are responsible for mitral valve disease in adults. Mitral valve repair has been widely regarded as the optimal surgical procedure to treat mitral valve dysfunction of all etiologies. The supporting evidence for repair over replacement is strongest in degenerative mitral regurgitation. The aim of the present review is to summarize the data in each category of mitral insufficiency and to provide recommendations based upon this data. PMID:26309824

  5. The effect of the aortic valve orientation on cavitation.

    Science.gov (United States)

    Johansen, Peter; Travis, Brandon R; Smerup, Morten; Decker Christensen, Thomas; Funder, Jonas; Nyboe, Camilla; Nygaard, Hans; Hasenkam, J Michael

    2016-08-01

    When implanting a mechanical aortic valve the annulus orientation is important with respect to turbulence. However, the effect on cavitation has not yet been investigated. The aim of this study was to investigate how cavitation is influenced hereof in vivo. Three pigs were included in the study. An Omnicarbon 21mm valve equipped with a rotating mechanism enabling controlled rotation of the valve was implanted in aortic position. Under stable hemodynamic conditions, measurements were performed using a hydrophone positioned at the aortic root. The valve was rotated from 0-360° in increments of 30°. From the pressure fluctuations recorded by the hydrophone the root mean square of the 50 kHz high pass filtered signal as well as the non-deterministic signal energy was calculated as indirect measures of cavitation. Various degrees of cavitation were measured but no relationship was found between either of the two cavitation measures and the valve orientation. Hemodynamics varied during the experiments for all pigs (3.9-5.7 l/min; 5.0-7.2 l/min; 3.1-7.5 l/min). Changes in cavitation quantities seemed to be caused by changes in hemodynamics rather than valve angular position. In conclusion, these results do not favor any position over another in terms of cavitation potential.

  6. Charging valve of the full hydraulic braking system

    Directory of Open Access Journals (Sweden)

    Jinshi Chen

    2016-03-01

    Full Text Available It is known that the full hydraulic braking system has excellent braking performance. As the key component of the full hydraulic braking system, the parameters of the accumulator charging valve have a significant effect on the braking performance. In this article, the key parameters of the charging valve are analyzed through the static theoretical and an Advanced Modeling Environment for performing Simulation of engineering systems (AMESim simulation model of the dual-circuit accumulator charging valve is established based on the real structure parameters first. Second, according to the results of the dynamic simulation, the dynamic characteristics of the charging pressure, the flow rate, and the frequency of the charging valve are studied. The key parameters affecting the serial production are proposed and some technical advices for improving the performance of the full hydraulic system are provided. Finally, the theoretical analysis is validated by the simulation results. The comparison between the simulation results and the experimental results indicates that the simulated AMESim model of the charging valve is accurate and credible with the error rate inside 0.5% compared with the experimental result. Hence, the performance of the charging valve meets the request of the full hydraulic braking system exactly.

  7. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Science.gov (United States)

    Baran, G.; Catana, I.; Magheti, I.; Safta, C. A.; Savu, M.

    2010-08-01

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  8. Controlling the cavitation phenomenon of evolution on a butterfly valve

    Energy Technology Data Exchange (ETDEWEB)

    Baran, G; Safta, C A [Department of Hydraulic and Hydraulic Machineries, University Politehnica of Bucharest, 313 Splaiul Independentei, Bucharest, 060042 (Romania); Catana, I [Department of Control and Computer Science, University Politehnica of Bucharest (Romania); Magheti, I; Savu, M, E-mail: baran_gheorghe@yahoo.co.u [Department of Mechanical Engineering, University Politehnica of Bucharest (Romania)

    2010-08-15

    Development of the phenomenon of cavitation in cavitation behavior requires knowledge of both plant and equipment working in the facility. This paper presents a diagram of cavitational behavior for a butterfly valve with a diameter of 100 mm at various openings, which was experimentally built. We proposed seven stages of evolution of the phenomenon of cavitation in the case of a butterfly valve. All these phases are characterized by pressure drop, noise and vibration at various flow rates and flow sections through the valve. The level of noise and vibration for the seven stages of development of the phenomenon of cavitation were measured simultaneously. The experimental measurements were comprised in a knowledge database used in training of a neural network of a neural flow controller that maintains flow rate constantly in the facility by changing the opening butterfly valve. A fuzzy position controller is used to access the valve open. This is the method proposed to provide operational supervision outside the cavitation for a butterfly valve.

  9. Three-dimensional echocardiographic assessment of the repaired mitral valve.

    Science.gov (United States)

    Maslow, Andrew; Mahmood, Feroze; Poppas, Athena; Singh, Arun

    2014-02-01

    This study examined the geometric changes of the mitral valve (MV) after repair using conventional and three-dimensional echocardiography. Prospective evaluation of consecutive patients undergoing mitral valve repair. Tertiary care university hospital. Fifty consecutive patients scheduled for elective repair of the mitral valve for regurgitant disease. Intraoperative transesophageal echocardiography. Assessments of valve area (MVA) were performed using two-dimensional planimetry (2D-Plan), pressure half-time (PHT), and three-dimensional planimetry (3D-Plan). In addition, the direction of ventricular inflow was assessed from the three-dimensional imaging. Good correlations (r = 0.83) and agreement (-0.08 +/- 0.43 cm(2)) were seen between the MVA measured with 3D-Plan and PHT, and were better than either compared to 2D-Plan. MVAs were smaller after repair of functional disease repaired with an annuloplasty ring. After repair, ventricular inflow was directed toward the lateral ventricular wall. Subgroup analysis showed that the change in inflow angle was not different after repair of functional disease (168 to 171 degrees) as compared to those presenting with degenerative disease (168 to 148 degrees; p<0.0001). Three-dimensional imaging provides caregivers with a unique ability to assess changes in valve function after mitral valve repair. Copyright © 2014 Elsevier Inc. All rights reserved.

  10. Ahmed glaucoma valve implant: surgical technique and complications

    Directory of Open Access Journals (Sweden)

    Riva I

    2017-02-01

    Full Text Available Ivano Riva,1 Gloria Roberti,1 Francesco Oddone,1 Anastasios GP Konstas,2 Luciano Quaranta3 1IRCCS “Fondazione GB Bietti per l’Oftalmologia”, Rome, Italy; 21st University Department of Ophthalmology, Glaucoma Unit, AHEPA Hospital, Thessaloniki, Greece; 3Department of Medical and Surgical Specialties, Section of Ophthalmology, University of Brescia, Brescia, Italy Abstract: Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications. Keywords: glaucoma, surgical technique, glaucoma drainage devices, Ahmed glaucoma valve, complications

  11. Measurements of flow past a bileaflet mechanical heart valve

    Science.gov (United States)

    Haya, Laura; Tavoularis, Stavros

    2013-11-01

    A bileaflet mechanical heart valve has been inserted in an axisymmetric model of the aorta within a mock circulation apparatus with physiological pressure and flow variations. The velocity field behind the valve has been measured with laser Doppler velocimetry and particle image velocimetry. The results closely match those reported by similar studies. A triple jet emanated from the valve's orifices and regions of reverse flow formed in the sinus region. Velocity fluctuations were greatest in the shear layers of the jets. The average r.m.s. streamwise velocity fluctuation over the turbulent period was 0.22 m/s; its maximum value was 0.53 m/s and occurred at the onset of deceleration. Measurements with the valve inserted in an anatomical model of the aorta are planned for the near future. The present and future measurements will be compared to determine the effects of the aorta anatomy on the characteristics of flow through bileaflet valves. In particular, measurements of the viscous and turbulent shear stresses will be analyzed to identify possible locations of blood element damage, and regions of recirculation and stagnation will be identified as locations favourable to thrombus growth. The effects of flows in branching arteries and valve orientation will also be investigated. Supported by NSERC.

  12. Development of cyclonic valves; Desenvolvimento de valvulas ciclonicas

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Carlos Alberto Capela; Marins, Luiz Philipe Martinez; Monteiro, Andre Sampaio; Silva, Fabricio Soares da [Centro de Pesquisas da Petrobras (CENPES). Gerencia de Tecnologia de Processamento e Avaliacao de Petroleo (Brazil)], e-mails: capela@petrobras.com.br, philipe@petrobras.com.br, asmonteiro@petrobras.com.br, fabriciosoares@petrobras.com.br; Souza, Marcos Aurelio de

    2009-06-15

    This study proposes a possible solution for one of the most severe problems encountered in primary oil-water separation - the formation of stable emulsions. This is largely due to the action of the conventional valves used in the production process and in primary processing activities. Choke and control valves, widely used devices in a production plant, are designed to inflict a significant pressure drop on a fluid stream to control process variables (flow-rate, liquid levels etc.). However, despite facilitating the production plant controllability, these pressure drops can cause deleterious effects on the primary processing activities, mainly on phase separation. Multiphase (oil + water or even gas + oil + water) streams are severely disturbed by the punctual high rate of turbulent energy dissipation due to the passage of the multiphase stream through the valve openings. The high turbulence level acts as a dispersion tool causing the formation of very severe oil in water and water in oil emulsions. This study describes a R and D project based on a new concept for a low shearing valve capable of imposing the required pressure drop on a multiphase process stream without creating emulsions and, in fact, helping to separate the distinct stream phases. PETROBRAS has protected the intellectual proprietary rights of this concept with registered patents. The conceptual design was further developed in a set of mechanical designs and prototypes. These were successfully tested by comparing their performance in terms of pressure drop characteristics and emulsion generation with those of conventional control valves. The concept and equipment have been completely proved and the next project stage will include the optimization of the valve geometry and contacting an equipment maker to study industrial production and commercialization. (author)

  13. High resolution imaging of the mitral valve in the natural state with 7 Tesla MRI.

    Science.gov (United States)

    Stephens, Sam E; Liachenko, Serguei; Ingels, Neil B; Wenk, Jonathan F; Jensen, Morten O

    2017-01-01

    Imaging techniques of the mitral valve have improved tremendously during the last decade, but challenges persist. The delicate changes in annulus shape and papillary muscle position throughout the cardiac cycle have significant impact on the stress distribution in the leaflets and chords, thus preservation of anatomically accurate positioning is critical. The aim of this study was to develop an in vitro method and apparatus for obtaining high-resolution 3D MRI images of porcine mitral valves in both the diastolic and systolic configurations with physiologically appropriate annular shape, papillary muscle positions and orientations, specific to the heart from which the valve was harvested. Positioning and mounting was achieved through novel, customized mounting hardware consisting of papillary muscle and annulus holders with geometries determined via pre-mortem ultrasonic intra-valve measurements. A semi-automatic process was developed and employed to tailor Computer Aided Design models of the holders used to mount the valve. All valve mounting hardware was 3D printed using a stereolithographic printer, and the material of all fasteners used were brass for MRI compatibility. The mounted valves were placed within a clear acrylic case, capable of holding a zero-pressure and pressurized liquid bath of a MRI-compatible fluid. Obtaining images from the valve submerged in liquid fluid mimics the natural environment surrounding the valve, avoiding artefacts due to tissue surface tension mismatch and gravitational impact on tissue shape when not neutrally buoyant. Fluid pressure was supplied by reservoirs held at differing elevations and monitored and controlled to within ±1mmHg to ensure that the valves remained steady. The valves were scanned in a 7 Tesla MRI system providing a voxel resolution of at least 80μm. The systematic approach produced 3D datasets of high quality which, when combined with physiologically accurate positioning by the apparatus, can serve as an

  14. Chemical Safety Alert: Shaft Blow-Out Hazard of Check and Butterfly Valves

    Science.gov (United States)

    Certain types of check and butterfly valves can undergo shaft-disk separation and fail catastrophically, even when operated within their design limits of pressure and temperature, causing toxic/flammable gas releases, fires, and vapor cloud explosions.

  15. Perfect and robust phase-locking of a spin transfer vortex nano-oscillator to an external microwave source

    Energy Technology Data Exchange (ETDEWEB)

    Hamadeh, A.; Loubens, G. de, E-mail: gregoire.deloubens@cea.fr; Klein, O. [Service de Physique de l' État Condensé (CNRS URA 2464), CEA Saclay, 91191 Gif-sur-Yvette (France); Locatelli, N.; Lebrun, R.; Grollier, J.; Cros, V. [Unité Mixte de Physique CNRS/Thales and Université Paris Sud 11, 1 av. Fresnel, 91767 Palaiseau (France); Naletov, V. V. [Service de Physique de l' État Condensé (CNRS URA 2464), CEA Saclay, 91191 Gif-sur-Yvette (France); Unité Mixte de Physique CNRS/Thales and Université Paris Sud 11, 1 av. Fresnel, 91767 Palaiseau (France); Institute of Physics, Kazan Federal University, Kazan 420008 (Russian Federation)

    2014-01-13

    We study the synchronization of the auto-oscillation signal generated by the spin transfer driven dynamics of two coupled vortices in a spin-valve nanopillar to an external source. Phase-locking to the microwave field h{sub rf} occurs in a range larger than 10% of the oscillator frequency for drive amplitudes of only a few Oersteds. Using synchronization at the double frequency, the generation linewidth is found to decrease by more than five orders of magnitude in the phase-locked regime (down to 1 Hz, limited by the resolution bandwidth of the spectrum analyzer) in comparison to the free running regime (140 kHz). This perfect phase-locking holds for frequency detuning as large as 2 MHz, which proves its robustness. We also analyze how the free running spectral linewidth impacts the main characteristics of the synchronization regime.

  16. Analysis of in-line check valve with respect to the pipeline dynamics

    Directory of Open Access Journals (Sweden)

    Klas Roman

    2017-01-01

    Full Text Available The following study is focused on the flow analysis within the concentric in-line check valve. In-line check valve is part of the pipe and shut off the stream of fluid. In case that backflow occurs on the downstream side, the valve is fully or partially lifted and then abruptly closes. This effect brings undesirable pressure shocks in the entire system. The study therefore deals with the CFD analysis of steady and unsteady flow with respect to velocity and pressure field. Especially unsteady calculation mode reflects the influence of local inertial acceleration acting on the fluid and on the valve. Analysis is complemented by equation of motion of a valve which interacts with the fluid.

  17. Design and development of a leak tight helium II valve with low thermal impact

    Science.gov (United States)

    Mills, G. L.

    1991-01-01

    The Lambda Point Experiment is a precision measurement of the specific heat of liquid helium near the lambda point phase transition, in the low gravity of the space shuttle. It requires a valve for the helium sample chamber that operates at helium II temperature, has minimal thermal disturbance to the rest of the instrument, and is leak tight to helium II. A valve meeting these and all of the other science and engineering requirements of the mission has been developed by Ball. Initially, both torque and pressure actuated valve concepts were considered; the final flight design is pressure actuated. The rational for this decision as well as the rest of the valve design are given. The paper also discusses the manufacturing and testing of the prototype and flight valves. Test data is presented and discussed.

  18. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  19. Phase Locking of CO(2) Lasers.

    Science.gov (United States)

    Weingartner, W; Schröder, K; Schuöcker, D

    2001-05-20

    A method of phase locking two CO(2) lasers by radiation exchange is presented. This phase-locking was achieved by use of a copper prism as a beam folding device in the resonators and extraction of the output radiation by a common output coupler. Energy exchange led to a phase-locked state if several locking conditions were fulfilled. The amount of radiation injected from one resonator to the second cavity could be adjusted by movement of the prism. The influence of the strength of coupling on the locking range was studied. The beat signal between the two unlocked lasers could be measured, whereas in the case of phase-locked operation twice the intensity was detected. Despite the inclusion of several assumptions, a simplified mathematical model delivered good agreement between calculated and experimental results.

  20. Phase-locked Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1991-01-01

    Detailed experimental characterization of the phase-locking at both DC and at microwave frequencies is presented for two closely spaced Josephson soliton (fluxon) oscillators. In the phase-locked state, the radiated microwave power exhibited an effective gain. With one common bias source......, a frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. The interacting soliton oscillators were modeled by two inductively coupled nonlinear transmission lines...

  1. Proportional control valves integrated in silicon nitride surface channel technology

    NARCIS (Netherlands)

    Groen, Maarten; Groenesteijn, Jarno; Meutstege, Esken; Brookhuis, Robert Anton; Brouwer, Dannis Michel; Lötters, Joost Conrad; Wiegerink, Remco J.

    2015-01-01

    We have designed and realized two types of proportional microcontrol valves in a silicon nitride surface channel technology process. This enables on-die integration of flow controllers with other surface channel devices, such as pressure sensors or thermal or Coriolis-based (mass) flow sensors, to

  2. Gas absorption studies in a butterfly valve scrubber

    Energy Technology Data Exchange (ETDEWEB)

    Beg, S.A.; Taheri, M.

    1974-09-01

    Gas absorption and pressure drop in a wetted butterfly valve constituting a novel scrubber system are investigated. The exceptional suitability of the butterfly device is demonstrated by its flexibility to adjust to large variations in both gas and liquid flow rates. (1 diagram, 5 graphs, 19 references)

  3. Two-step rocket engine bipropellant valve concept

    Science.gov (United States)

    Capps, J. E.; Ferguson, R. E.; Pohl, H. O.

    1969-01-01

    Initiating combustion of altitude control rocket engines in a precombustion chamber of ductile material reduces high pressure surges generated by hypergolic propellants. Two-step bipropellant valve concepts control initial propellant flow into precombustion chamber and subsequent full flow into main chamber.

  4. Phase locking between Josephson soliton oscillators

    DEFF Research Database (Denmark)

    Holst, T.; Hansen, Jørn Bindslev; Grønbech-Jensen, N.

    1990-01-01

    We report observations of phase-locking phenomena between two Josephson soliton (fluxon) oscillators biased in self-resonant modes. The locking strength was measured as a function of bias conditions. A frequency tunability of the phase-locked oscillators up to 7% at 10 GHz was observed. Two coupled...... perturbed sine-Gordon equations were derived from an equivalent circuit consisting of inductively coupled, nonlinear, lossy transmission lines. These equations were solved numerically to find the locking regions. Good qualitative agreement was found between the experimental results and the calculations...

  5. Microcontroller-based locking in optics experiments.

    Science.gov (United States)

    Huang, K; Le Jeannic, H; Ruaudel, J; Morin, O; Laurat, J

    2014-12-01

    Optics experiments critically require the stable and accurate locking of relative phases between light beams or the stabilization of Fabry-Perot cavity lengths. Here, we present a simple and inexpensive technique based on a stand-alone microcontroller unit to perform such tasks. Easily programmed in C language, this reconfigurable digital locking system also enables automatic relocking and sequential functioning. Different algorithms are detailed and applied to fringe locking and to low- and high-finesse optical cavity stabilization, without the need of external modulations or error signals. This technique can readily replace a number of analog locking systems advantageously in a variety of optical experiments.

  6. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural...

  7. [Effect of transcatheter aortic valve replacement using Venus-A valve for treating patients with severe aortic stenosis].

    Science.gov (United States)

    Song, G Y; Wang, M Y; Wang, Y; Liu, X B; Feng, Y; Kong, X Q; Wu, Y J

    2017-10-24

    Objective: To evaluate the effect of transcatheter aortic valve replacement(TAVR) using Venus-A valve for treating patients with severe aortic stenosis. Methods: In this prospective study, 101 consecutive severe aortic stenosis patients with high surgical risk(Society of Thoracic Surgeon(STS) score ≥4%) or at prohibitive surgical risk were enrolled from 5 academic cardiovascular centers in China(Fuwai hospital, the second affiliated hospital of Zhejiang university school of medicine, West China hospital of Sichuan university, the first affiliated hospital of Nanjing medical university, Ruijin hospital of Shanghai Jiaotong university school of medicine) from September 2012 to January 2015, and Venus-A valves were used in TAVR for these patients. The primary endpoints were death from any cause and major stroke in 1 year. The secondary endpoints included efficacy and safety of TAVR in 1 year. Results: TAVR success rate was 97.9%(98/101), and 3 patients were transferred to receive surgical AVR. There were 85 patients using 1 Venus-A valve, and 13 patients underwent valve-in-valve implantation using 2 Venus-A valves. There were 1 case(1.0%) of stroke, 2 cases(2.0%)of acute myocardial infarction, 5 cases(5.0%) of pericardial effusion, 6 cases(5.9%) of severe vascular complication, and 2 cases(2.0%) of death after 7 days of TAVR. Meanwhile, aortic pressure gradient derived from echocardiography was significantly reduced when compared with pre-procedure level(11(8, 15) mmHg (1 mmHg=0.133 kPa) vs. 59(45, 71)mmHg, PVenus-A valve for treating patients with severe aortic stenosis is effective and safe in the early and medium term post procedure.

  8. In vitro evaluation of implantation depth in valve-in-valve using different transcatheter heart valves.

    Science.gov (United States)

    Simonato, Matheus; Azadani, Ali N; Webb, John; Leipsic, Jonathon; Kornowski, Ran; Vahanian, Alec; Wood, David; Piazza, Nicolo; Kodali, Susheel; Ye, Jian; Whisenant, Brian; Gaia, Diego; Aziz, Mina; Pasala, Tilak; Mehilli, Julinda; Wijeysundera, Harindra C; Tchetche, Didier; Moat, Neil; Teles, Rui; Petronio, Anna Sonia; Hildick-Smith, David; Landes, Uri; Windecker, Stephan; Arbel, Yaron; Mendiz, Oscar; Makkar, Raj; Tseng, Elaine; Dvir, Danny

    2016-09-18

    Transcatheter heart valve (THV) implantation in failed bioprosthetic valves (valve-in-valve [ViV]) offers an alternative therapy for high-risk patients. Elevated post-procedural gradients are a significant limitation of aortic ViV. Our objective was to assess the relationship between depth of implantation and haemodynamics. Commercially available THVs used for ViV were included in the analysis (CoreValve Evolut, SAPIEN XT and the Portico valve). THVs were implanted in small surgical valves (label size 19 mm) to simulate boundary conditions. Custom-mounted pulse duplicators registered relevant haemodynamic parameters. Twenty-eight experiments were performed (13 CVE, 5 SXT and 10 Portico). Ranges of depth of implantation were: CVE: -1.2 mm to 15.7 mm; SXT: -2.2 mm to 7.5 mm; Portico: 1.4 mm to 12.1 mm. Polynomial regression established a relationship between depth of implantation and valvular mean gradients (CVE: p<0.001; SXT: p=0.01; Portico: p=0.002), as well as with EOA (CVE: p<0.001; SXT: p=0.02; Portico valve: p=0.003). In addition, leaflet coaptation was better in the high implantation experiments for all valves. The current comprehensive bench testing assessment demonstrates the importance of high device position for the attainment of optimal haemodynamics during aortic ViV procedures.

  9. Energy dynamics of the intraventricular vortex after mitral valve surgery.

    Science.gov (United States)

    Nakashima, Kouki; Itatani, Keiichi; Kitamura, Tadashi; Oka, Norihiko; Horai, Tetsuya; Miyazaki, Shohei; Nie, Masaki; Miyaji, Kagami

    2017-09-01

    Mitral valve morphology after mitral valve surgery affects postoperative intraventricular flow patterns and long-term cardiac performance. We visualized ventricular flow by echocardiography vector flow mapping (VFM) to reveal the impact of different mitral valve procedures. Eleven cases of mechanical mitral valve replacement (nine in the anti-anatomical and two in the anatomical position), three bioprosthetic mitral valve replacements, and four mitral valve repairs were evaluated. The mean age at the procedure was 57.4 ± 17.8 year, and the echocardiography VFM in the apical long-axis view was performed 119.9 ± 126.7 months later. Flow energy loss (EL), kinetic pressure (KP), and the flow energy efficiency ratio (EL/KP) were measured. The cases with MVR in the anatomical position and with valve repair had normal vortex directionality ("Clockwise"; N = 6), whereas those with MVR in the anti-anatomical position and with a bioprosthetic mitral valve had the vortex in the opposite direction ("Counterclockwise"; N = 12). During diastole, vortex direction had no effect on EL ("Clockwise": 0.080 ± 0.025 W/m; "Counterclockwise": 0.083 ± 0.048 W/m; P = 0.31) or KP ("Clockwise": 0.117 ± 0.021 N; "Counterclockwise": 0.099 ± 0.057 N; P = 0.023). However, during systole, the EL/KP ratio was significantly higher in the "Counterclockwise" vortex than that in the "Clockwise" vortex (1.056 ± 0.463 vs. 0.617 ± 0.158; P = 0.009). MVP and MVR with a mechanical valve in the anatomical position preserve the physiological vortex, whereas MVR with a mechanical valve in the anti-anatomical position and a bioprosthetic mitral valve generate inefficient vortex flow patterns, resulting in a potential increase in excessive cardiac workload.

  10. High Reliability Cryogenic Piezoelectric Valve Actuator Project

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  11. Study on the design of industrial control valves with manual drive

    Directory of Open Access Journals (Sweden)

    Pascariu Andrei

    2017-01-01

    Full Text Available The paper presents the main components and the operating mode of the manually operated control valves used in natural gas transport and distribution installations. Main parameters are specified: inlet-outlet pressure (P, temperature(T, flow rate (Q, which are taken into considerations from the design phase and beyond. Noise is another parameter, in close liaison with the pressure and flow. As their value increases with both the inlet noise levels downstream of the valve is greater. By optimizing internal components, especially cages, noise can be limited below the maximum allowed by regulations. Also, there are presented control valve constructive types so that the optimal variant can be chose.

  12. Modelling of flow in the unloading slot of the control valve

    Science.gov (United States)

    Mrózek, Lukáš; Tajč, Ladislav

    2017-09-01

    The flow in the unloading system of the control valve is modelled. Values of the flow coefficient for various slot widths and openings are evaluated. The changes of pressure in the spaces of the valve are recorded when the performance of the turbine is regulated and its impacts on the level of the stabilizing power at the given setting of the cone lift are evaluated. The results from experiments on the air model of the system are compared with the pressures measured on the model of the valve. The operational characteristics of the experimental steam turbine is considered.

  13. A Type System for Unstructured Locking that Guarantees Deadlock Freedom without Imposing a Lock Ordering

    Directory of Open Access Journals (Sweden)

    Prodromos Gerakios

    2011-10-01

    Full Text Available Deadlocks occur in concurrent programs as a consequence of cyclic resource acquisition between threads. In this paper we present a novel type system that guarantees deadlock freedom for a language with references, unstructured locking primitives, and locks which are implicitly associated with references. The proposed type system does not impose a strict lock acquisition order and thus increases programming language expressiveness.

  14. «Réception de Locke au Danemark: Holberg, lecteur de Locke»

    DEFF Research Database (Denmark)

    Schøsler, Jørn

    Der gives en analyse af Holbergs læsning af Locke i Moralske Tanker og Epistler. Der fokuseres på hans holdning til Locke's Essay, hvor han synes fascineret af 'hypotesen om den tænkende materie' og problemet om de 'medfødte ideer'. Han tilslutter sig Locke's empirisme, men forsvarer dog en medfødt...

  15. Unusual Cause of Knee Locking

    OpenAIRE

    Huri, Gazi; Bi?er, Omer Sunkar

    2013-01-01

    We report a case of partial intrasubstance tear of popliteus tendon as an unusual cause of pseudolocking of the knee. A 13-year-old semiprofessional soccer player applied to our clinic with a locked right knee in spite of the therapy applied (cold pack, NSAID, and immobilization) in another institution 20 days after the injury. Significant extension loss was observed in his right knee with 30∘–90∘ ROM. Magnetic resonance imaging (MRI) and arthroscopy confirmed the intrasubstance tear of popli...

  16. Coupled optical resonance laser locking

    CSIR Research Space (South Africa)

    Burd, CC

    2014-10-01

    Full Text Available . The coupled resonance technique discussed here overcomes this obstacle, and works as follows. If the 2S1/2 → 2P1/2 transition is driven at resonance, there will be a net increase of ions in the 2D3/2 state and a decrease in the population of ions in the ground... stream_source_info Burd_2014.pdf.txt stream_content_type text/plain stream_size 31258 Content-Encoding UTF-8 stream_name Burd_2014.pdf.txt Content-Type text/plain; charset=UTF-8 Coupled optical resonance laser locking S...

  17. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...

  18. Butterfly valve apparatus and method

    Energy Technology Data Exchange (ETDEWEB)

    Ball, L.K.; Hines, M.U.; Miller, T.L.

    1990-10-23

    This patent describes a method of controlling fluid flow in a duct, and duct having a wall bounding a flow path wherein flows the fluid. It comprises: disposing a plate-like valve member in the flow path, which valve member is pivotally movable about an axis generally transverse to the duct between a first position transverse to and closing the flow path and a second position generally parallel with the flow path to open and allow fluid flow therein: transecting the valve member with the pivot axis to define with respect to direction of the fluid flow in the duct and pivotal movement of the valve member toward the open position an upstream valve member wing and a downstream valve member wing each substantially equal in area: increasing the effective area of the valve member upon which the fluid flow exerts fluid dynamic flow forces; and pivoting the valve member toward the second open position thereof in response to the increase of effective area.

  19. The spin-valve transistor

    NARCIS (Netherlands)

    Anil Kumar, P.S.; Lodder, J.C.

    2000-01-01

    The spin-valve transistor is a magnetoelectronic device that can be used as a magnetic field sensor. It has a ferromagnet-semiconductor hybrid structure. Using a vacuum metal bonding technique, the spin-valve transistor structure Si/Pt/NiFe/Au/Co/Au/Si is obtained. It employs hot electron transport

  20. Mechanical Valve Replacement: Early Results

    Directory of Open Access Journals (Sweden)

    Habib Cakir

    2012-03-01

    Conclusion: Mechanical prosthetic valves are used for surgical treatment of valve disease with low mortality and morbidity in a large group of patients like women that not to think to get pregnant, non advanced age group and patients have less risky for anticoagulation drug in our clinic. [Cukurova Med J 2012; 37(1: 49-54

  1. 40 CFR 63.169 - Standards: Pumps, valves, connectors, and agitators in heavy liquid service; instrumentation...

    Science.gov (United States)

    2010-07-01

    ..., and agitators in heavy liquid service; instrumentation systems; and pressure relief devices in liquid...: Pumps, valves, connectors, and agitators in heavy liquid service; instrumentation systems; and pressure..., pressure relief devices in light liquid or heavy liquid service, and instrumentation systems shall be...

  2. Study on Friction and Wear Characteristics of Aluminum Alloy Hydraulic Valve Body and Its Antiwear Mechanism

    Directory of Open Access Journals (Sweden)

    Rong Li

    2017-03-01

    Full Text Available In order for the working status of the aluminum alloyed hydraulic valve body to be controlled in actual conditions, a new friction and wear design device was designed for the cast iron and aluminum alloyed valve bodies comparison under the same conditions. The results displayed that: (1 The oil leakage of the aluminum alloyed hydraulic valve body was higher than the corresponding oil leakage of the iron body during the initial running stage. Besides during a later running stage, the oil leakage of the aluminum alloyed body was lower than corresponding oil leakage of the iron body; (2 The actual oil leakage of different materials consisted of two parts: the foundation leakage that was the leakage of the valve without wear and wear leakage that was caused by the worn valve body; (3 The aluminum alloyed valve could rely on the dust filling furrow and melting mechanism that led the body surface to retain dynamic balance, resulting in the valve leakage preservation at a low level. The aluminum alloy modified valve body can meet the requirements of hydraulic leakage under pressure, possibly constituting this alloy suitable for hydraulic valve body manufacturing.

  3. First-in-man implantation of the retrievable and repositionable VenusA-Plus valve.

    Science.gov (United States)

    Liu, Xian-Bao; He, Yu-Xin; Liu, Chun-Hui; Wang, Li-Han; Gao, Feng; Yu, Lei; Dong, Ai-Qiang; Kong, Min-Jian; Chen, Ji-Fang; Xu, Yong; Zhou, Qi-Jing; Yan, Min; Wang, Jian-An

    2018-01-01

    No retrievable and repositionable second generation transcatheter aortic valve is available in China. Here, we report the first-in-man implantation of the retrievable and repositionable VenusA-Plus valve. A 76-year-old patient with symptomatic severe aortic stenosis and high surgical risk (STS 13.8%) was recommended for transcatheter aortic valve replacement (TAVR) by heart valve team. Type 0 bicuspid aortic valve with asymmetric calcification was identified by dual source computed tomography, and the unfavorable anatomies increased the possibility of malposition and paravalvular leakage during TAVR. Therefore, we used the retrievable and repositionable VenusA-Plus valve for the patient. Transfemoral TAVR was performed under local anesthesia with sedation, and a 26mm VenusA-Plus valve was successfully implanted. No transvalvular pressure gradient and trace paravalvular leakage were found. The successful first-in-man implantation indicates the retrievable and repositionable VenusA-Plus valve is feasible in complicated TAVR cases such as bicuspid aortic valve.

  4. A low-volume tester for the thrombogenic potential of mechanical heart valve prostheses.

    Science.gov (United States)

    Linde, Torsten; Hamilton, Kathrin F; Timms, Daniel L; Schmitz-Rode, Thomas; Steinseifer, Ulrich

    2011-09-01

    During the development of a mechanical heart valve prosthesis, many studies are conducted to guarantee its correct function. Currently, investigations into the thrombogenic potential of a valve after its replacement are conducted with expensive and time-consuming chronic animal trials. Hence, the study aim was to develop and test an alternative system to resolve such thrombogenic issues. The Thrombosis Tester of the Helmholtz Institute Aachen (THIA II) has a reasonably small priming volume (220-270 ml) that allows analysis of the thrombogenic potential of two valves, using one human blood bottle. Hydrodynamic evaluation demonstrated an absolutely stable physiological pressure and flow progression at the aortic and pulmonary positions. A sinus geometry of the human aortic root is implemented downstream of the valve in order to guarantee physiological leaflet motion. The tester remained absolutely thrombus-free during several tests carried out with minimally anticoagulated porcine blood, while the valves showed reproducible thrombus formation in reasonable locations. Tests with fully heparinized porcine blood showed that a soft silicon fixture for the valve could reduce hemolysis in the THIA II. This in-vitro test protocol can enable the optimization of a valve design during the early stages of its research and development. The system can provide a unique and suitable supplement to animal trials for testing thrombogenic performance, under constant and reproducible boundary conditions, including considerable physiological and pathological circumstances such as the influence of valve position (aortic, pulmonic), and a comparison of different valve types.

  5. Heart valve scaffold fabrication: Bioinspired control of macro-scale morphology, mechanics and micro-structure.

    Science.gov (United States)

    D'Amore, Antonio; Luketich, Samuel K; Raffa, Giuseppe M; Olia, Salim; Menallo, Giorgio; Mazzola, Antonino; D'Accardi, Flavio; Grunberg, Tamir; Gu, Xinzhu; Pilato, Michele; Kameneva, Marina V; Badhwar, Vinay; Wagner, William R

    2018-01-01

    Valvular heart disease is currently treated with mechanical valves, which benefit from longevity, but are burdened by chronic anticoagulation therapy, or with bioprosthetic valves, which have reduced thromboembolic risk, but limited durability. Tissue engineered heart valves have been proposed to resolve these issues by implanting a scaffold that is replaced by endogenous growth, leaving autologous, functional leaflets that would putatively eliminate the need for anticoagulation and avoid calcification. Despite the diversity in fabrication strategies and encouraging results in large animal models, control over engineered valve structure-function remains at best partial. This study aimed to overcome these limitations by introducing double component deposition (DCD), an electrodeposition technique that employs multi-phase electrodes to dictate valve macro and microstructure and resultant function. Results in this report demonstrate the capacity of the DCD method to simultaneously control scaffold macro-scale morphology, mechanics and microstructure while producing fully assembled stent-less multi-leaflet valves composed of microscopic fibers. DCD engineered valve characterization included: leaflet thickness, biaxial properties, bending properties, and quantitative structural analysis of multi-photon and scanning electron micrographs. Quasi-static ex-vivo valve coaptation testing and dynamic organ level functional assessment in a pressure pulse duplicating device demonstrated appropriate acute valve functionality. Copyright © 2017. Published by Elsevier Ltd.

  6. Performance of bioprosthetic valves after glycerol dehydration, ethylene oxide sterilization, and rehydration.

    Science.gov (United States)

    Fumoto, Hideyuki; Chen, Ji-Feng; Zhou, Qun; Massiello, Alex L; Dessoffy, Raymond; Fukamachi, Kiyotaka; Navia, Jose L

    2011-01-01

    : Most commercially available bioprosthetic valves are stored in an aldehyde solution. We report a new alternative method: Self-expanding valves composed of dehydrated tissues with a high glycerin:water ratio can be collapsed into specially designed sheaths prior to sterilization for ease of delivery and storage. : Changes in tissue dimension of five samples of bovine pericardium were evaluated from baseline after glycerol treatment, air-drying, ethylene oxide (EtO) sterilization, and rehydration with water. Three valves fabricated from glutaraldehyde cross-linked tissues, including porcine pericardial tissue, bovine pericardial tissue, and porcine aortic valve, were dehydrated through a proprietary glycerin-based process, collapsed, placed within a catheter, EtO sterilized, stored for up to 212 days, and rehydrated with water. These valves were characterized in a mock circulation by mounting them at the inlet portion of a pneumatic pump before dehydration and after rehydration to evaluate the effects of dehydration and rehydration on the valve performance. : Tissues treated with glycerol solution showed no significant changes in dimension from baseline after glycerol treatment, air-drying, EtO sterilization, and rehydration with water. In all the valves, pump flows reached the maximum output capacity of the pneumatic pump after rehydration without an increase in filling pressures as compared with those before dehydration. : This method for storing collapsible bioprosthetic valves using a proprietary glycerin-based process demonstrated excellent valve performance.

  7. Numerical simulation on a throttle governing system with hydraulic butterfly valves in a marine environment

    Science.gov (United States)

    Wan, Hui-Xiong; Fang, Jun; Huang, Hui

    2010-12-01

    Hydraulic butterfly valves have been widely applied in marine engineering because of their large switching torque, low pressure loss and suitability for large and medium diameter pipelines. Due to control problems resulting from switching angular speeds of the hydraulic butterfly valve, a throttle-governing control mode has been widely adopted, and detailed analysis has been carried out worldwide on the structural principle concerning speed-regulation and the load torque on the shaft while opening or closing a hydraulic butterfly valve. However relevant reports have yet been published on the change law, the error and the influencing factors of the rotational angular velocity of the hydraulic butterfly valve while opening and closing. In this article, research was based on some common specifications of a hydraulic butterfly valve with a symmetrical valve flap existing in a marine environment. The throttle governing system supplied by the accumulator to achieve the switching of the hydraulic control valve was adopted, and the mathematical models of the system were established in the actual conditions while the numerical simulations took place. The simulation results and analysis show that the rotational angular velocity and the error of the hydraulic butterfly valve while switching is influenced greatly by the drainage amount of the accumulator, resulting in pressure loss in the pipeline, the temperature of hydraulic medium and the load of the hydraulic butterfly valve. The simulation results and analysis provide a theoretical basis for the choice of the total capacity of the accumulator and pipeline diameters in a throttle governing system with a hydraulic butterfly valve. It also determines the type and specification of the hydraulic butterfly valve and the design of motion parameters of the transported fluid.

  8. Evaluating All-Metal Valves for Use in a Tritium Environment

    Energy Technology Data Exchange (ETDEWEB)

    Houk, L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Payton, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-09-28

    In the tritium gas processing system, it is desired to minimize polymer components due to their degradation from tritium exposure (beta decay). One source of polymers in the tritium process is valve components. A vendor has been identified that manufactures a valve that is marketed as being made from all-metal construction. This manufacturer, Ham-Let Group, manufactures a diaphragm valve (3LE series) that claims to be made entirely of metal. SRNL procured twelve (12) Ham-Let diaphragm valves for characterization and evaluation. The characterization tests include identification of the maximum pressure of these valves by performing pressure and burst tests. Leak tests were performed to ensure the valves do not exceed the acceptable leak rate for tritium service. These valves were then cycled in a nitrogen gas and/or vacuum environment to ensure they would be durable in a process environment. They were subsequently leak tested per ASTM protocol to ensure that the valves maintained their leak tight integrity. A detailed material analysis was also conducted to determine hydrogen and tritium compatibility.

  9. Development and experimental characterization of a pneumatic valve actuated by a dielectric elastomer membrane

    Science.gov (United States)

    Hill, Marc; Rizzello, Gianluca; Seelecke, Stefan

    2017-08-01

    Due to their many features including lightweight and low energy consumption, dielectric elastomer (DE) membrane actuators are of interest for a number of industrial applications, such as pumping systems or valve control units. In particular, the use of DEs in valve control units offers advantages over traditional solenoid valves, including lower power requirements and relative simplicity in achieving proportional control. Additionally, DEs generate low thermal dissipation and are capable of virtually silent operation. The contribution of this work is the development of a new valve system based on a circular DE membrane pre-loaded with a linear spring. The valve is designed for pressurized air and operates by actuating a lever mechanism that opens and closes an outlet port. After presenting the operating principle and system design, several experiments are presented to compare actuator force, stroke, and dissipated energy for several pressure differentials and associated volume flows. It is observed that the DE-driven valve achieves a performance similar to a solenoid-based valve, while requiring a significantly lower amount of input energy. In addition, it is shown that DE-membrane valves can be controlled proportionally by simply adjusting the actuator voltage.

  10. Express consent and full membership in Locke

    NARCIS (Netherlands)

    den Hartogh, G.A.

    1990-01-01

    It seems mysterious why Locke required express consent as a condition of full membership of civil society. It is suggested this requirement be interpreted as a political programme. In a draft of a pamphlet of 1690 Locke criticizes the oath of allegiance required after the Glorious Revolution for not

  11. Past, Present, Future Erosion at Locke Island

    Energy Technology Data Exchange (ETDEWEB)

    Bjornstad, Bruce N.

    2006-08-08

    This report describes and documents the erosion that has occurred along the northeast side of Locke Island over the last 10 to 20 years. The principal cause of this erosion is the massive Locke Island landslide complex opposite the Columbia River along the White Bluffs, which constricts the flow of the river and deflects the river's thalweg southward against the island.

  12. A method for real-time in vitro observation of cavitation on prosthetic heart valves.

    Science.gov (United States)

    Zapanta, C M; Liszka, E G; Lamson, T C; Stinebring, D R; Deutsch, S; Geselowitz, D B; Tarbell, J M

    1994-11-01

    A method for real-time in vitro observation of cavitation on a prosthetic heart valve has been developed. Cavitation of four blood analog fluids (distilled water, aqueous glycerin, aqueous polyacrylamide, and aqueous xanthan gum) has been documented for a Medtronic/Hall prosthetic heart valve. This method employed a Penn State Electrical Ventricular Assist Device in a mock circulatory loop that was operated in a partial filling mode associated with reduced atrial filling pressure. The observations were made on a valve that was located in the mitral position, with the cavitation occurring on the inlet side after valve closure on every cycle. Stroboscopic videography was used to document the cavity life cycle. Bubble cavitation was observed on the valve occluder face. Vortex cavitation was observed at two locations in the vicinity of the valve occluder and housing. For each fluid, cavity growth and collapse occurred in less than one millisecond, which provides strong evidence that the cavitation is vaporous rather than gaseous. The cavity duration time was found to decrease with increasing atrial pressure at constant aortic pressure and beat rate. The area of cavitation was found to decrease with increasing delay time at a constant aortic pressure, atrial pressure, and beat rate. Cavitation was found to occur in each of the fluids, with the most cavitation seen in the Newtonian fluids (distilled water and aqueous glycerin).

  13. Characteristics of transonic moist air flows around butterfly valves with spontaneous condensation

    Directory of Open Access Journals (Sweden)

    A.B.M. Toufique Hasan

    2015-06-01

    Full Text Available Effects of spontaneous condensation of moist air on the shock wave dynamics around butterfly valves in transonic flows are investigated by experimental and numerical simulations. Two symmetric valve disk shapes namely- a flat rectangular plate and a mid-plane cross-section of a prototype butterfly valve have been studied in the present research. Results showed that in case with spontaneous condensation, the root mean square of pressure oscillation (induced by shock dynamics is reduced significantly with those without condensation for both shapes of the valves. Moreover, local aerodynamic moments were reduced in case with condensation which is considered to be beneficial in torque requirement in case of on/off applications of valves as flow control devices. However, total pressure loss was increased with spontaneous condensation in both the valves. Furthermore, the disk shape of a prototype butterfly valve showed better aerodynamic performances compared to flat rectangular plate profile in respect of total pressure loss and vortex shedding frequency in the wake region.

  14. A new approach to heart valve tissue engineering

    DEFF Research Database (Denmark)

    Kaasi, Andreas; Cestari, Idágene A.; Stolf, Noedir A G.

    2011-01-01

    chamber. Subsequently, applied vacuum to the pneumatic chamber causes the blood chamber to fill. A mechanical heart valve was placed in the VAD's inflow position. The tissue engineered (TE) valve was placed in the outflow position. The VAD was coupled in series with a Windkessel compliance chamber......The 'biomimetic' approach to tissue engineering usually involves the use of a bioreactor mimicking physiological parameters whilst supplying nutrients to the developing tissue. Here we present a new heart valve bioreactor, having as its centrepiece a ventricular assist device (VAD), which exposes...... the cell-scaffold constructs to a wider array of mechanical forces. The pump of the VAD has two chambers: a blood and a pneumatic chamber, separated by an elastic membrane. Pulsatile air-pressure is generated by a piston-type actuator and delivered to the pneumatic chamber, ejecting the fluid in the blood...

  15. Drive piston assembly for a valve actuator assembly

    Science.gov (United States)

    Sun, Zongxuan

    2010-02-23

    A drive piston assembly is provided that is operable to selectively open a poppet valve. The drive piston assembly includes a cartridge defining a generally stepped bore. A drive piston is movable within the generally stepped bore and a boost sleeve is coaxially disposed with respect to the drive piston. A main fluid chamber is at least partially defined by the generally stepped bore, drive piston, and boost sleeve. First and second feedback chambers are at least partially defined by the drive piston and each are disposed at opposite ends of the drive piston. At least one of the drive piston and the boost sleeve is sufficiently configured to move within the generally stepped bore in response to fluid pressure within the main fluid chamber to selectively open the poppet valve. A valve actuator assembly and engine are also provided incorporating the disclosed drive piston assembly.

  16. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  17. Postoperative Outcomes of Mitral Valve Repair for Mitral Restenosis after Percutaneous Balloon Mitral Valvotomy

    Directory of Open Access Journals (Sweden)

    Seong Lee

    2015-10-01

    Full Text Available Background: There have been a number of studies on mitral valve replacement and repeated percutaneous mitral balloon valvotomy for mitral valve restenosis after percutaneous mitral balloon valvotomy. However, studies on mitral valve repair for these patients are rare. In this study, we analyzed postoperative outcomes of mitral valve repair for mitral valve restenosis after percutaneous mitral balloon valvotomy. Methods: In this study, we assessed 15 patients (mean age, 47.7±9.7 years; 11 female and 4 male who underwent mitral valve repair between August 2008 and March 2013 for symptomatic mitral valve restenosis after percutaneous mitral balloon valvotomy. The mean interval between the initial percutaneous mitral balloon valvotomy and the mitral valve repair was 13.5±7 years. The mean preoperative Wilkins score was 9.4±2.6. Results: The mean mitral valve area obtained using planimetry increased from 1.16±0.16 cm2 to 1.62±0.34 cm2 (p=0.0001. The mean pressure half time obtained using Doppler ultrasound decreased from 202.4±58.6 ms to 152±50.2 ms (p=0.0001. The mean pressure gradient obtained using Doppler ultrasound decreased from 9.4±4.0 mmHg to 5.8±1.5 mmHg (p=0.0021. There were no early or late deaths. Thromboembolic events or infective endocarditis did not occur. Reoperations such as mitral valve repair or mitral valve replacement were not performed during the follow-up period (39±16 months. The 5-year event-free survival was 56.16% (95% confidence interval, 47.467–64.866. Conclusion: On the basis of these results, we could not conclude that mitral valve repair could be an alternative for patients with mitral valve restenosis after percutaneous balloon mitral valvotomy. However, some patients presented with results similar to those of mitral valve replacement. Further studies including more patients with long-term follow-up are necessary to determine the possibility of this application of mitral valve repair.

  18. Experiments and Valve Modelling in Thermoacoustic Device

    Science.gov (United States)

    Duthil, P.; Baltean Carlès, D.; Bétrancourt, A.; François, M. X.; Yu, Z. B.; Thermeau, J. P.

    2006-04-01

    In a so called heat driven thermoacoustic refrigerator, using either a pulse tube or a lumped boost configuration, heat pumping is induced by Stirling type thermodynamic cycles within the regenerator. The time phase between acoustic pressure and flow rate throughout must then be close to that met for a purely progressive wave. The study presented here relates the experimental characterization of passive elements such as valves, tubes and tanks which are likely to act on this phase relationship when included in the propagation line of the wave resonator. In order to carry out a characterization — from the acoustic point of view — of these elements, systematic measurements of the acoustic field are performed varying various parameters: mean pressure, oscillations frequency, supplied heat power. Acoustic waves are indeed generated by use of a thermoacoustic prime mover driving a pulse tube refrigerator. The experimental results are then compared with the solutions obtained with various one-dimensional linear models including non linear correction factors. It turns out that when using a non symmetrical valve, and for large dissipative effects, the measurements disagree with the linear modelling and non linear behaviour of this particular element is shown.

  19. 46 CFR 154.802 - Alternate pressure relief settings.

    Science.gov (United States)

    2010-10-01

    ... 46 Shipping 5 2010-10-01 2010-10-01 false Alternate pressure relief settings. 154.802 Section 154... Equipment Cargo Vent Systems § 154.802 Alternate pressure relief settings. Cargo tanks with more than one relief valve setting must have one of the following arrangements: (a) Relief valves that: (1) Are set and...

  20. Unusual Cause of Knee Locking

    Directory of Open Access Journals (Sweden)

    Gazi Huri

    2013-01-01

    Full Text Available We report a case of partial intrasubstance tear of popliteus tendon as an unusual cause of pseudolocking of the knee. A 13-year-old semiprofessional soccer player applied to our clinic with a locked right knee in spite of the therapy applied (cold pack, NSAID, and immobilization in another institution 20 days after the injury. Significant extension loss was observed in his right knee with 30∘–90∘ ROM. Magnetic resonance imaging (MRI and arthroscopy confirmed the intrasubstance tear of popliteus tendon and synovitis. The ruptured part of the tendon was debrided, and the inflammatory tissue around the tendon, which may lead to pseudolocking, was gently removed with a shaver in order to regain the normal ROM. The patient was discharged with full ROM and weight bearing first day after the surgery. To our knowledge, this is the first case demonstrating intrasubstance tear of popliteus tendon causing pseudolocking of the knee.

  1. Working Characteristics of Variable Intake Valve in Compressed Air Engine

    Directory of Open Access Journals (Sweden)

    Qihui Yu

    2014-01-01

    Full Text Available A new camless compressed air engine is proposed, which can make the compressed air energy reasonably distributed. Through analysis of the camless compressed air engine, a mathematical model of the working processes was set up. Using the software MATLAB/Simulink for simulation, the pressure, temperature, and air mass of the cylinder were obtained. In order to verify the accuracy of the mathematical model, the experiments were conducted. Moreover, performance analysis was introduced to design compressed air engine. Results show that, firstly, the simulation results have good consistency with the experimental results. Secondly, under different intake pressures, the highest output power is obtained when the crank speed reaches 500 rpm, which also provides the maximum output torque. Finally, higher energy utilization efficiency can be obtained at the lower speed, intake pressure, and valve duration angle. This research can refer to the design of the camless valve of compressed air engine.

  2. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  3. Ahmed glaucoma valve implant: surgical technique and complications.

    Science.gov (United States)

    Riva, Ivano; Roberti, Gloria; Oddone, Francesco; Konstas, Anastasios Gp; Quaranta, Luciano

    2017-01-01

    Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

  4. Thermostatic Radiator Valve Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Dentz, J. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States); Ansanelli, E. [Advanced Residential Integrated Energy Solutions Collaborative (ARIES), New York, NY (United States)

    2015-01-01

    A large stock of multifamily buildings in the Northeast and Midwest are heated by steam distribution systems. Losses from these systems are typically high and a significant number of apartments are overheated much of the time. Thermostatically controlled radiator valves (TRVs) are one potential strategy to combat this problem, but have not been widely accepted by the residential retrofit market. In this project, the ARIES team sought to better understand the current usage of TRVs by key market players in steam and hot water heating and to conduct limited experiments on the effectiveness of new and old TRVs as a means of controlling space temperatures and reducing heating fuel consumption. The project included a survey of industry professionals, a field experiment comparing old and new TRVs, and cost-benefit modeling analysis using BEopt™ (Building Energy Optimization software).

  5. Left atrial volume as predictor of valve replacement and cardiovascular events in patients with asymptomatic mild to moderate aortic stenosis

    DEFF Research Database (Denmark)

    Dalsgaard, Morten; Egstrup, Kenneth; Wachtell, Kristian

    2013-01-01

    Left atrial (LA) size is known to increase with chronically increased left ventricular (LV) filling pressure. We hypothesized that LA volume was predictive of aortic valve replacement (AVR) and cardiovascular events in a large cohort of patients with asymptomatic mild to moderate aortic valve...

  6. Considerations Regarding the Stresses and the Deformations of the Butterfly Valve Body

    Directory of Open Access Journals (Sweden)

    Florin Peris-Bendu

    2013-09-01

    Full Text Available In the present paper it is analyzed the “von Mises” equivalent stress distribution, respectively strains, which appear in the body of a butterfly valve with nominal diameter (DN of 2800 mm and operates at a nominal pressure (PN 19 bar. The paper examines the body of a butterfly valve using finite element method and the followings data is considered to be known: boundary conditions for which the analysis is made in both positions, the valve disk in the closed position and the open position, mechanical characteristics and resistance of the materials for valve body components and loads to which it is subject. The result of the analysis obtained allow optimization of the valve body size by highlighting the oversized areas respectively areas where efforts are maximized.

  7. Test of a Novel Moving Magnet Actuated Seat Valve for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Madsen, Esben Lundø; Christensen, Jeppe Haals

    2018-01-01

    electronicallycontrolled moving magnet actuated (MMA) annular seat valve is proposed, designed, built, and tested rigorously in the laboratory. The actuator is energized using one coil only, it has bidirectional force capability and it utilizes magnetic latching to keep it open instead of a spring. The annular seat valve...... has two metering edges; the static pressure drop is 0.11/0.31 bar at -142/108 l/min, respectively. The valve closing time is 4-6 ms depending on the flow rate. The MMA valve is tested experimentally in both standalone test rigs besides in situ tests in a fully operational digital displacement proto...... type machine. Measurements provided for pumping and motoring operation at 800 RPM/100 bar demonstrate that the proposed MMA valve topology is a promising candidate for energy-efficient digital displacement machines. Key characteristics include little power consumption, good switching performance...

  8. Design of a multi-poppet on-off valve for wave energy converters

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik C.; Andersen, Torben Ole

    2013-01-01

    Fluid power systems are the leading technology for the power take off system in ocean wave energy converters. However, fluid power systems often suffer from poor efficiency, especially in part loads. This degrades the PTO system efficiency and therefore lower the energy production. To overcome th......, structural mechanical issues and modelling and simulation of various valve configurations. Hence in the design process a wide variety of topics are combined to chose the best valve configuration....... than 15 ms. The pilot stage is directly actuated and utilises internal valve pressure as supply and an external tank connection as drain. The current article presents the design process leading to the final valve design. This includes the geometric design of the main stage, the choice of pilot valve...

  9. 3D Printed Multimaterial Microfluidic Valve

    OpenAIRE

    Keating, Steven J.; Gariboldi, Maria Isabella; Patrick, William G.; Sharma, Sunanda; Kong, David S.; Oxman, Neri

    2016-01-01

    We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deform...

  10. No Snowball on Habitable Tidally Locked Planets

    Science.gov (United States)

    Checlair, Jade; Menou, Kristen; Abbot, Dorian S.

    2017-08-01

    The TRAPPIST-1, Proxima Centauri, and LHS 1140 systems are the most exciting prospects for future follow-up observations of potentially inhabited planets. All of the planets orbit nearby M-stars and are likely tidally locked in 1:1 spin-orbit states, which motivates the consideration of the effects that tidal locking might have on planetary habitability. On Earth, periods of global glaciation (snowballs) may have been essential for habitability and remote signs of life (biosignatures) because they are correlated with increases in the complexity of life and in the atmospheric oxygen concentration. In this paper, we investigate the snowball bifurcation (sudden onset of global glaciation) on tidally locked planets using both an energy balance model and an intermediate-complexity global climate model. We show that tidally locked planets are unlikely to exhibit a snowball bifurcation as a direct result of the spatial pattern of insolation they receive. Instead, they will smoothly transition from partial to complete ice coverage and back. A major implication of this work is that tidally locked planets with an active carbon cycle should not be found in a snowball state. Moreover, this work implies that tidally locked planets near the outer edge of the habitable zone with low CO2 outgassing fluxes will equilibrate with a small unglaciated substellar region rather than cycling between warm and snowball states. More work is needed to determine how the lack of a snowball bifurcation might affect the development of life on a tidally locked planet.

  11. Treatment of Aortic, Mitral and Tricuspid Structural Bioprosthetic Valve Deterioration Using the Valve-in-Valve Technique.

    Science.gov (United States)

    Codner, Pablo; Assali, Abid; Vaknin-Assa, Hana; Shapira, Yaron; Orvin, Katia; Sharony, Ram; Sagie, Alexander; Kornowski, Ran

    2015-05-01

    The percutaneous approach for a failed bioprosthetic valve is an emerging alternative to redo-valve surgery in patients at high surgical risk. The study aim was to describe the treatment of patients with structural bioprosthetic valve deterioration, using the valve-in-valve technique. A total of 33 consecutive patients with symptomatic structural bioprosthetic valve deterioration was treated at the authors' institution, using the valve-in-valve technique. The valve-in-valve procedure in the aortic position was performed in 23 patients (mean age 81.4 ± 5.9 years; mean STS score 9.6 ± 5.4). The self-expandable and balloon-expandable devices were used in 21 cases (91.3%) and two cases (8.7%), respectively. Procedures were performed via the trans-femoral, trans-axillary and trans-apical routes in 18 (78.2%), three (13%) and two (8.7%) cases, respectively. After the procedure, all patients were in NYHA class I/II. Survival rates were 95.6% at the one-year follow up. The valve-in-valve procedure in the mitral position was performed in 10 patients (mean age 73.6 ± 15 years; mean STS score 7.7 ± 4.1). All procedures were performed using the balloon-expandable device via the trans-apical route. The composite end point of device success was achieved in all patients. Survival rates were 100% and 75% at one month and two years' follow up, respectively. A single valve-in-valve implantation within a failed tricuspid bioprosthetic valve was also successfully performed. In the authors' experience, the valve-in-valve technique for the treatment of a wide range of bioprosthetic valve deterioration modes of failure in different valve positions is safe and very effective.

  12. Optimal database locks for efficient integrity checking

    DEFF Research Database (Denmark)

    Martinenghi, Davide

    2004-01-01

    In concurrent database systems, correctness of update transactions refers to the equivalent effects of the execution schedule and some serial schedule over the same set of transactions. Integrity constraints add further semantic requirements to the correctness of the database states reached upon...... the execution of update transactions. Several methods for efficient integrity checking and enforcing exist. We show in this paper how to apply one such method to automatically extend update transactions with locks and simplified consistency tests on the locked entities. All schedules produced in this way...... are conflict serializable and preserve consistency. For certain classes of databases we also guarantee that the amount of locked database entities is minimal....

  13. Correlations between locked modes and impurity influxes

    Energy Technology Data Exchange (ETDEWEB)

    Fishpool, G.M. [Commission of the European Communities, Abingdon (United Kingdom). JET Joint Undertaking; Lawson, K.D. [UKAEA Culham Lab., Abingdon (United Kingdom)

    1994-07-01

    An analysis of pulses that were disturbed by medium Z impurity influxes (Cl, Cr, Fe and Ni) recorded during the 91/92 JET operations, has demonstrated that such influxes can result in MHD modes which subsequently ``lock``. A correlation is found between the power radiated by the influx and the time difference between the start of the influx and the beginning of the locked mode. The growth in the amplitude of the locked mode itself can lead to further impurity influxes. A correlation is noted between intense influxes (superior to 10 MW) and the mode ``unlocking``. (authors). 4 refs., 4 figs.

  14. Tracheostomy tube manometry: evaluation of speaking valves, capping and need for downsizing.

    Science.gov (United States)

    Johnson, Douglas Clark; Campbell, Stacy Lynn; Rabkin, Judith Dawn

    2009-01-01

    Readiness to speak is a major problem for many tracheostomized patients. Evaluation for tracheostomy tube capping or speaking valve is often subjective. We first wanted to assess whether there were differences among speaking valves. We developed a care pathway for tracheostomy tube evaluation and management including manometry, which we wanted to evaluate. Three different speaking valves were assessed using manometry and measuring dyspnea in 21 patients. Subsequently, 100 consecutive patients referred for tracheostomy tube evaluation in a long-term acute-care rehabilitation hospital were studied using our care pathway with manometry before and after tracheostomy tube changes. Inspiratory pressures differed among the speaking valves. Borg scale was higher among patients with high expiratory pressures. Of the 100 patients, following our care pathway, speech (speaking valve or capping) was recommended for 78 patients with their initial tube, and for 93 patients within 2 days of their initial evaluation. Tracheostomy tube downsizing was recommended in 94 patients. Downsizing led to significant reductions in airway pressures. Capping was initially recommended for 12 patients and for 71 following downsizing. Women had higher pressures than men for the same size tubes. Tracheostomy tube manometry is very helpful in objectively guiding recommendations for speaking valve use, capping, and changing tracheostomy tubes. Speech is an early recommendation for most patients.

  15. Energy Cost of Avoiding Pressure Oscillations in a Discrete Fluid Power Force System

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Pedersen, Henrik Clemmensen

    2015-01-01

    In secondary valve controlled discrete fluid power force systems the valve opening trajectory greatly influences the pressure dynamics in the actuator chambers. For discrete fluid power systems featuring hoses of significant length pressure oscillations due to fast valve switching is well...... converters. Further the energy losses introduced during the shifting period is investigated and compared for two valve opening algorithms. The investigation of the energy loss is utilised to quantify the importance of a fast valve switching and the energy cost of reducing pressure oscillations. The paper...... will present measurements comparing pressure dynamics for two valve opening algorithms. In addition the paper will give a theoretical investigation of the energy loss during valve shifting and finally measurements of average power output from the power take-off system in various sea states are compared...

  16. Intraoperative assessment of mitral valve area after mitral valve repair: comparison of different methods.

    Science.gov (United States)

    Maslow, Andrew; Gemignani, Anthony; Singh, Arun; Mahmood, Feroze; Poppas, Athena

    2011-04-01

    In the present study, 3 different methods to measure the mitral valve area (MVA) after mitral valve repair (MVRep) were studied. Data obtained immediately after repair were compared with postoperative data. The objective was to determine the feasibility and correlation between intraoperative and postoperative MVA data. A prospective study. A tertiary care medical center. Twenty-five elective adult surgical patients scheduled for MVRep. Echocardiographic data included MVAs obtained using the pressure half-time (PHT), 2-dimensional planimetry (2D-PLAN), and the continuity equation (CE). These data were obtained immediately after cardiopulmonary bypass and were compared with data obtained before hospital discharge (transthoracic echocardiogram 1) and 6 to 12 months after surgery (transthoracic echocardiogram 2). Intraoperative care was guided by hemodynamic goals designed to optimize cardiac function. The data show good agreement and correlation between MVA obtained with PHT and 2D-PLAN within and between each time period. MVA data obtained with the CE in the postoperative period were lower than and did not correlate or agree as well with other MVA data. The MVA recorded immediately after valve repair, using PHT, correlated and agreed with MVA data obtained in the postoperative period. These results contrast with previously published data and could highlight the impact of hemodynamic function during the assessment of MVA. Copyright © 2011 Elsevier Inc. All rights reserved.

  17. Exercise Testing and Stress Imaging in Mitral Valve Disease.

    Science.gov (United States)

    Voilliot, Damien; Lancellotti, Patrizio

    2017-03-01

    Mitral valve disease represented by mitral stenosis and mitral regurgitation is the second most frequent valvulopathy. Mitral stenosis leads to an increased left atrial pressure whereas mitral regurgitation leads to an increased left atrial pressure associated with a volume overload. Secondary to an upstream transmission of this overpressure, both mitral stenosis and regurgitation lead to pulmonary hypertension and right heart failure. In addition, mitral regurgitation also leads to left ventricular dilatation and dysfunction with left heart failure. Depending on the anatomy of the valvular and subvalvular apparatus, valve repair (percutaneous mitral commissurotomy for mitral stenosis and valvuloplasty for mitral regurgitation) might be possible. If the anatomy is not favorable, valve replacement by mechanical or biological prosthesis is indicated. Most of the intervention indications are based on clinical symptoms and resting transthoracic echocardiography. Outcomes of patients operated based upon resting echo abnormalities might however not be optimal. Therefore early intervention might be beneficial based upon abnormal exercise testing, which has been demonstrated to more sensitive to identify high-risk patients. In this last decade, especially exercise echocardiography has been found to be a crucial tool in the management of patients with mitral valve disease.

  18. 27 CFR 19.282 - Breaking Government locks.

    Science.gov (United States)

    2010-04-01

    ... 27 Alcohol, Tobacco Products and Firearms 1 2010-04-01 2010-04-01 false Breaking Government locks... Breaking Government locks. Where affixed, Government locks shall not be removed without the authorization... obtain authorization from an appropriate TTB officer, Government locks may be removed, by the proprietor...

  19. Effect of Flow Characteristics in the Downstream of Butterfly Valve on the Flow Rate Measurement using Venturi Tube

    Science.gov (United States)

    Yoon, Seok Ho; Lee, Jungho; Yu, Cheong Hwan; Park, San-Jin; Chung, Chang-Hwan

    2010-06-01

    For testing large-capacity pump, the accurate flow rate measurement is needed in the test loop. As a measuring method of flow rate, venturi tube is recommended due to its low pressure loss. However, upstream disturbance of loop component such as valve has an effect upon the accuracy of flow rate measurement. For controlling flow rate in case of high flow rate and large-scale piping system, butterfly-type valve is generally used due to its compactness. However, butterfly valve disturbs downstream flow by generating turbulence, cavities, or abrupt pressure change. In this study, the effect of downstream disturbance of butterfly valve on the flow rate measurement using venturi tube is investigated. Test loop consists of circulation pump, reservoir, butterfly valve, venturi tube, and reference flow meter. The test is conducted with regard to a different valve opening angle of butterfly valve. PIV system is used to visualize and analyze flow in the downstream region of butterfly valve. According to valve opening angle, the flow characteristics and the accuracy of flow rate measurement are investigated.

  20. The Structure of Wheel Check Valve Influence on Air Block Phenomenon of Piezoelectric Micro-Pump

    Directory of Open Access Journals (Sweden)

    Song Chen

    2015-11-01

    Full Text Available To improve the stability and reliability of the piezoelectric micro-pump, the cause of air block phenomenon is analyzed on the structure of wheel check valve. During the movement of the bubble in the micro-channel, pressure drop occurs, the main factor which influences the bubble going through is opening height of the wheel check valve. Five groups of wheel check valves with different structures are used to test the wheel check valve opening height and air block probability. The experiment results show that reducing the wheel check valve thickness or diameter ratio can both increase the wheel check valve opening height, and decrease the air block probability. Through experiment, the optimum combination of the wheel check valve structure is obtained within the samples: as the thickness is 0.02 mm, the diameter ratio is 1.2, the wheel check valve opening height gets 252 µm, and within the given bubble volume, the air block probability is less than 2%.

  1. Topology Selection and Analysis of Actuator for Seat Valves suitable for use in Digital Displacement Pumps/Motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    and switching times within a few milliseconds. These valves are mechatronic components and attention to both the electromagnetic, fluid dynamical, mechanical and control system design must be paid to ensure the needed performance. In the present work, a quick response linear electro-magnetic actuator for DD...... seat valves is developed, and the resulting dynamic response of the seat valve is presented. Requirements for the valve actuator is established based on the DD application, and three feasible actuator topologies are analyzed by means of transient electro-magnetic FEA simulation. From this analysis...... a moving coil actuator topology is selected for the DD valve. A lumped parameter model including magnetic diffusion effects of this chosen actuator is developed, which is included in the dynamic valve simulation. Result show a switching time below 2 ms and a pressure loss below 0.5 bar at 500 litres...

  2. Comparing the Overhead of Lock-based and Lock-free Implementations of Priority Queues

    DEFF Research Database (Denmark)

    Passas, Stavros; Karlsson, Sven

    2011-01-01

    With the advent of multi-core processors, concurrent data structures have received a renewed interest. While concurrent data structures where previously used mainly in high-performance computing, now they are found in all types of computer systems. A major challenge when designing such data...... instructions as the lock-based implementation. However, the lock-free implementation outperforms the lock-based when multiple cores are used and the data structure is contended....

  3. Clinical Implication of Transaortic Mitral Pannus Removal During Repeat Cardiac Surgery for Patients With Mechanical Mitral Valve.

    Science.gov (United States)

    Park, Byungjoon; Sung, Kiick; Park, Pyo Won

    2018-01-25

    This study aimed to evaluate the safety and feasibility of transaortic mitral pannus removal (TMPR).Methods and Results:Between 2004 and 2016, 34 patients (median age, 57 years; 30 women) with rheumatic disease underwent pannus removal on the ventricular side of a mechanical mitral valve through the aortic valve during reoperation. The median time interval from the previous surgery was 14 years. TMPR was performed after removal of the mechanical aortic valve (n=21) or diseased native aortic valve (n=11). TMPR was performed in 2 patients through a normal aortic valve. The mitral transprosthetic mean pressure gradient (TMPG) was ≥5 mmHg in 11 patients, including 3 with prosthetic valve malfunction. Prophylactic TMPR was performed in 23 patients. There were no early deaths. Concomitant operations included 22 tricuspid valve surgeries (13 replacements, 15 repairs) and 32 aortic valve replacements (24 repeats, 8 primary). The mean gradient in patients who had mitral TMPG ≥5 mmHg was significantly decreased from 6.46±1.1 to 4.37±1.17 mmHg at discharge (Pvalve malfunction was apparent on last echocardiography. TMPR is a safe and effective procedure for patients with malfunction or stenosis of a mechanical mitral valve and may be considered an alternative approach in patients with pannus overgrowth in such valves.

  4. Anaesthetic machine pipeline inlet pressure gauges do not always measure pipeline pressure.

    Science.gov (United States)

    Craig, D B; Longmuir, J

    1980-09-01

    Some anaesthetic gas machines have pipeline inlet pressure gauges which indicate the higher of either pipeline pressure, or machine circuit pressure (the pressure distal to the pressure reducing valve, and proximal to the flowmeter control valve). Failure by the operator to appreciate this feature may in specific circumstances lead to a delayed appreciation of pipeline malfunction or disconnection. The Canadian Standards Association Z168.3-M1980 Anaesthetic Gas Machine Standard requires pipeline inlet gauges which measure only pipeline (hose) pressure. Existing machines should be modified to accommodate this requirement.

  5. Design and Optimization of Fast Switching Valves for Large Scale Digital Hydraulic Motors

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck

    The present thesis is on the design, analysis and optimization of fast switching valves for digital hydraulic motors with high power ratings. The need for such high power motors origins in the potential use of hydrostatic transmissions in wind turbine drive trains, as digital hydraulic machines...... have been shown to improve the overall efficiency and efficient operation range compared to traditional hydraulic machines. Digital hydraulic motors uses electronically controlled independent seat valves connected to the pressure chambers, which must be fast acting and exhibit low pressure losses...... to enable efficient operation. These valves are complex components to design, as multiple design aspects are present in these integrated valve units, with conflicting objectives and interdependencies. A preliminary study on a small scale single-cylinder digital hydraulic pump has initially been conducted...

  6. Heart sounds as a result of acoustic dipole radiation of heart valves

    Science.gov (United States)

    Kasoev, S. G.

    2005-11-01

    Heart sounds are associated with impulses of force acting on heart valves at the moment they close under the action of blood-pressure difference. A unified model for all the valves represents this impulse as an acoustic dipole. The near pressure field of this dipole creates a distribution of the normal velocity on the breast surface with features typical of auscultation practice: a pronounced localization of heart sound audibility areas, an individual area for each of the valves, and a noncoincidence of these areas with the projections of the valves onto the breast surface. In the framework of the dipole theory, the optimum size of the stethoscope’s bell is found and the spectrum of the heart sounds is estimated. The estimates are compared with the measured spectrum.

  7. Optimization of geometry of annular seat valves suitable for Digital Displacement fluid power pumps/motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    work an annular seat valve suitable for use in Digital Displacement units is considered, and the ring geometry is optimized using finite element analysis including non-linear material behaviour, contact elements and fluid pressure penetrating load, closely reflecting the actual load of the seat valve......Digital Displacement Fluid Power is an upcoming technology setting new standards for the achievable efficiency of fluid power pumps and motors. The core element of the Digital Displacement technology is high performance electronically controlled seat valves, which must exhibit very low flow...... pressure loss and switching times within a few milliseconds to enable high efficiency operation. These valves are mechatronic components and special attention to both the mechanical, electromagnetic, fluid dynamical and control system design must be paid to ensure the needed performance. In the present...

  8. Effect of Ahmed valve implantation on late neovascular glaucoma

    Directory of Open Access Journals (Sweden)

    Ping-An Mao

    2013-09-01

    Full Text Available AIM: To discuss the effect and safety of Ahmed valve implantation in late neovascular glaucoma. METHODS: The Ahmed glaucoma valve were implanted in 41 eyes(41 caseswith late neovascular glaucoma, the follow-up was 12 months on average, intraocular pressure was recorded at 1 day, 1 week, 1 month, 3, 6, 12 months respectively after operation and compared with that before operation, at the same time, the complications and treatment were analyzed.RESULTS: The mean intraocular pressure before operation, 1 day, 1 week, 1 month, 3, 6, 12 months after operation was 59.83±5.53, 19.27±8.19, 19.69±6.86, 20.67±6.73, 21.05±6.93, 21.49±7.42, 22.14±8.08mmHg, the mean intraocular pressure before operation was higher than that after operation and the difference was obvious in statistics. Major complications included hyphema, low intraocular pressure early postoperation, shallow anterior chamber, obstruction of the tube, the plate wrapped or exposed.CONCLUSION: Ahmed valve implantation is an effective method to treatlate neovascular glaucoma.

  9. Transcatheter Replacement of Failed Bioprosthetic Valves

    DEFF Research Database (Denmark)

    Simonato, Matheus; Webb, John; Kornowski, Ran

    2016-01-01

    valve mechanism of failure (stenosis/mixed baseline failure: odds ratio, 3.12; confidence interval, 1.51-6.45; P=0.002). Conclusions-High implantation inside failed bioprosthetic valves is a strong independent correlate of lower postprocedural gradients in both self-and balloon-expandable transcatheter......Background-Transcatheter valve implantation inside failed bioprosthetic surgical valves (valve-in-valve [ViV]) may offer an advantage over reoperation. Supra-annular transcatheter valve position may be advantageous in achieving better hemodynamics after ViV. Our objective was to define targets...... for implantation that would improve hemodynamics after ViV. Methods and Results-Cases from the Valve-in-Valve International Data (VIVID) registry were analyzed using centralized core laboratory assessment blinded to clinical events. Multivariate analysis was performed to identify independent predictors of elevated...

  10. Suture locking of isolated internal locking knotless suture anchors is not affected by bone quality

    Directory of Open Access Journals (Sweden)

    Woodmass JM

    2015-06-01

    Full Text Available Jarret M Woodmass,1 Graeme Matthewson,1 Yohei Ono,1,2 Aaron J Bois,1 Richard S Boorman,1 Ian KY Lo,1 Gail M Thornton1,31Department of Surgery, Section of Orthopaedic Surgery, McCaig Institute for Bone and Joint Health, University of Calgary, Calgary, AB, Canada; 2Department of Orthopaedic Surgery, Nagoya University Graduate School of Medicine, Nagoya, Japan; 3Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada Purpose: The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock, ii internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew, or iii a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S. Methods: Anchors were tested in foam blocks representing normal (20/8 foam or osteopenic (8/8 foam bone, using standard suture loops pulled in-line with the anchor to isolate suture locking. Mechanical testing included cyclic testing for 500 cycles from 10 N to 60 N at 60 mm/min, followed by failure testing at 60 mm/min. Displacement after 500 cycles at 60 N, number of cycles at 3 mm displacement, load at 3 mm displacement, and maximum load were evaluated. Results: Comparing 8/8 foam to 20/8 foam, load at 3 mm displacement and maximum load were significantly decreased (P<0.05 with decreased bone quality for anchors that, even in part, relied on an interference fit suture locking mechanism (ie, 4.5 mm PushLock, 5.5 mm SwiveLock, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S. Bone quality did not affect the mechanical performance of 5.5 mm SpeedScrew anchors which have an isolated internal locking mechanism. Conclusion: The mechanical performance of anchors that relied, even in part, on interference fit were affected by bone quality. Isolated internal locking knotless suture anchors functioned independently of bone quality

  11. La filosofia del lenguaje de Locke

    National Research Council Canada - National Science Library

    Arango, Alejandro Patino

    2006-01-01

    ... en la Filosofia Analitica del siglo XX. Esta influencia se presenta a traves del analisis que realiza Locke sobre el papel que cumple el lenguaje en el problema del conocimiento, lo cual lo conduce a criticar la metafisica, concebir...

  12. QPSK regeneration without active phase-locking

    DEFF Research Database (Denmark)

    Kjøller, Niels-Kristian; Da Ros, Francesco; Røge, Kasper Meldgaard

    2016-01-01

    QPSK regeneration without active phase stabilization is investigated in numerical simulations. We propose an improved scheme for phase-locking free QPSK regeneration showing significant improvements in the error vector magnitude of the signal....

  13. Universal Spin-Momentum Locked Optical Forces

    CERN Document Server

    Kalhor, Farid; Jacob, Zubin

    2015-01-01

    Evanescent electromagnetic waves possess spin-momentum locking, where the direction of propagation (momentum) is locked to the inherent polarization of the wave (transverse spin). We study the optical forces arising from this universal phenomenon and show that the fundamental origin of recently reported non-trivial optical chiral forces is spin-momentum locking. For evanescent waves, we show that the direction of energy flow, direction of decay, and direction of spin follow a right hand rule for three different cases of total internal reflection, surface plasmon polaritons, and $HE_{11}$ mode of an optical fiber. Furthermore, we explain how the recently reported phenomena of lateral optical force on chiral and achiral particles is caused by the transverse spin of the evanescent field and the spin-momentum locking phenomenon. Finally, we propose an experiment to identify the unique lateral forces arising from the transverse spin in the optical fiber and point to fundamental differences of the spin density from...

  14. Mode-locked silicon evanescent lasers

    National Research Council Canada - National Science Library

    Brian R. Koch; Alexander W. Fang; Oded Cohen; John E. Bowers

    2007-01-01

    .... The mode locked lasers generate 4 ps pulses with low jitter and extinction ratios above 18 dB, making them suitable for data and telecommunication transmitters and for clock generation and distribution...

  15. Conceptual design and selection of deposited metal on the valve seat for the high temperature isolation valve in the HTTR hydrogen production system (contract research)

    Energy Technology Data Exchange (ETDEWEB)

    Nishihara, Tetsuo; Iwatsuki, Jin [Department of Advanced Nuclear Heat Technology, Oarai Research Establishment, Japan Atomic Energy Research Institute, Oarai, Ibaraki (Japan)

    1999-11-01

    In the HTTR hydrogen production system a high temperature isolation valve should be provided outside the penetration of containment vessel on the secondary helium loop. As the secondary helium gas is at temperature of 905degC and pressure of 4.1 MPa, there is not any available isolation valve used under such conditions. Once demonstration test of high temperature isolation valve was carried out in the ERANS project. Tested valve could meet the basic design requirements but some problems remained. In this report a conceptual design of the high temperature isolation valve is performed in consideration of resolving these problems. The structural reliability is confirmed by the three-dimensional stress analysis. With respect to the deposited metal on valve seat, a screening test is done to observe the basic properties of candidate metals. From these results, it is shown that Stellite alloy that is used in practical valve has a possibility of the separation at welding layer and carbon diffusion from deposited metal into the base metal. Nickel-base super alloy has a possibility of internal and intergranular oxidation due to contained Al and Ti. Therefore, detail metallographical and mechanical tests for long period are planned to select the adequate deposited metal. (author)

  16. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  17. Self-mode-locking semiconductor disk laser.

    Science.gov (United States)

    Gaafar, Mahmoud; Richter, Philipp; Keskin, Hakan; Möller, Christoph; Wichmann, Matthias; Stolz, Wolfgang; Rahimi-Iman, Arash; Koch, Martin

    2014-11-17

    The development of mode-locked semiconductor disk lasers received striking attention in the last 14 years and there is still a vast potential of such pulsed lasers to be explored and exploited. While for more than one decade pulsed operation was strongly linked to the employment of a saturable absorber, self-mode-locking emerged recently as an effective and novel technique in this field - giving prospect to a reduced complexity and improved cost-efficiency of such lasers. In this work, we highlight recent achievements regarding self-mode-locked semiconductor devices. It is worth to note, that although nonlinear effects in the active medium are expected to give rise to self-mode-locking, this has to be investigated with care in future experiments. However, there is a controversy whether results presented with respect to self-mode-locking truly show mode-locking. Such concerns are addressed in this work and we provide a clear evidence of mode-locking in a saturable-absorber-free device. By using a BBO crystal outside the cavity, green light originating from second-harmonic generation using the out-coupled laser beam is demonstrated. In addition, long-time-span pulse trains as well as radiofrequency-spectra measurements are presented for our sub-ps pulses at 500 MHz repetition rate which indicate the stable pulse operation of our device. Furthermore, a long-time-span autocorrelation trace is introduced which clearly shows absence of a pedestal or double pulses. Eventually, a beam-profile measurement reveals the excellent beam quality of our device with an M-square factor of less than 1.1 for both axes, showing that self-mode-locking can be achieved for the fundamental transverse mode.

  18. Transverse mode-locking in microcavity lasers

    Science.gov (United States)

    Gordon, R.; Heberle, A. P.; Cleaver, J. R. A.

    2002-12-01

    We experimentally demonstrate mode-locking between the transverse modes of a laser. A vertical-cavity surface-emitting laser with evenly-spaced transverse modes is shown to emit a train of 2.1±0.1 ps pulses with an 11 ps repetition rate and a timing jitter of 235±30 fs. Transverse mode-locking in microcavity lasers has potential to improve the compactness, stability, integrability, repetition rate tunability, and efficiency of ultrafast optical communication sources.

  19. Locked intramedullary total wrist arthrodesis.

    Science.gov (United States)

    Orbay, Jorge L; Feliciano, Eric; Orbay, Carolina

    2012-11-01

    Total wrist arthrodesis is commonly performed using fixation plates, which can produce soft tissue irritation, often require removal, and limit the ability to position the hand in space. The Skeletal Dynamics IMPLATE is an intramedullary total wrist fusion device designed to provide stable fixation while avoiding the problems associated with plates. Radial and metacarpal locked intramedullary nails are inserted and joined by a connector. Desired hand placement is achieved by selecting the proper connector length and angle, then orienting it appropriately. Fusion mass compression is obtained by virtue of longitudinal threads on the radial nail that allow for length adjustment. Seven wrists in three men and four women were treated with this device and followed for a minimum of 24 weeks. In all cases, local cancellous bone graft was used and the third carpometacarpal (CMC) joint incorporated into the fusion. The median age was 49 (range, 28-71) years. Indications for fusion were two posttraumatic arthritides, three rheumatoid arthritides, one spastic deformity, and one infection. Patients were evaluated before surgery and at final follow-up using the Fernandez pain score and grip strength measurements using a hand-held dynamometer. All patients improved their grip strength and decreased their pain scores. All fusions united, and none of the patients presented dorsal soft tissue problems or required implant removal. One rheumatoid patient required secondary surgery for removal of a retained palmar osteophyte. This device delivers stable fixation, facilitates hand placement, and does not require removal.

  20. Free fructose is conformationally locked.

    Science.gov (United States)

    Cocinero, Emilio J; Lesarri, Alberto; Écija, Patricia; Cimas, Álvaro; Davis, Benjamin G; Basterretxea, Francisco J; Fernández, José A; Castaño, Fernando

    2013-02-20

    Fructose has been examined under isolation conditions using a combination of UV ultrafast laser vaporization and Fourier-transform microwave (FT-MW) spectroscopy. The rotational spectra for the parent, all (six) monosubstituted (13)C species, and two single D species reveal unambiguously that the free hexoketose is conformationally locked in a single dominant β-pyranose structure. This six-membered-chair skeleton adopts a (2)C(5) configuration (equivalent to (1)C(4) in aldoses). The free-molecule structure sharply contrasts with the furanose form observed in biochemically relevant polysaccharides, like sucrose. The structure of free fructose has been determined experimentally using substitution and effective structures. The enhanced stability of the observed conformation is primarily attributed to a cooperative network of five intramolecular O-H···O hydrogen bonds and stabilization of both endo and exo anomeric effects. Breaking a single intramolecular hydrogen bond destabilizes the free molecule by more than 10 kJ mol(-1). The structural results are compared to ribose, recently examined with rotational resolution, where six different conformations coexist with similar conformational energies. In addition, several DFT and ab initio methods and basis sets are benchmarked with the experimental data.

  1. Effect Analysis of Design Variables on the Disc in a Double-Eccentric Butterfly Valve

    OpenAIRE

    Kang, Sangmo; Kim, Da-Eun; Kim, Kuk-Kyeom; Kim, Jun-Oh

    2014-01-01

    We have performed a shape optimization of the disc in an industrial double-eccentric butterfly valve using the effect analysis of design variables to enhance the valve performance. For the optimization, we select three performance quantities such as pressure drop, maximum stress, and mass (weight) as the responses and three dimensions regarding the disc shape as the design variables. Subsequently, we compose a layout of orthogonal array (L16) by performing numerical simulations on the flow an...

  2. Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

    Science.gov (United States)

    2011-01-01

    Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS) model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV) loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves. PMID:21942971

  3. Mathematical multi-scale model of the cardiovascular system including mitral valve dynamics. Application to ischemic mitral insufficiency

    Directory of Open Access Journals (Sweden)

    Moonen Marie

    2011-09-01

    Full Text Available Abstract Background Valve dysfunction is a common cardiovascular pathology. Despite significant clinical research, there is little formal study of how valve dysfunction affects overall circulatory dynamics. Validated models would offer the ability to better understand these dynamics and thus optimize diagnosis, as well as surgical and other interventions. Methods A cardiovascular and circulatory system (CVS model has already been validated in silico, and in several animal model studies. It accounts for valve dynamics using Heaviside functions to simulate a physiologically accurate "open on pressure, close on flow" law. However, it does not consider real-time valve opening dynamics and therefore does not fully capture valve dysfunction, particularly where the dysfunction involves partial closure. This research describes an updated version of this previous closed-loop CVS model that includes the progressive opening of the mitral valve, and is defined over the full cardiac cycle. Results Simulations of the cardiovascular system with healthy mitral valve are performed, and, the global hemodynamic behaviour is studied compared with previously validated results. The error between resulting pressure-volume (PV loops of already validated CVS model and the new CVS model that includes the progressive opening of the mitral valve is assessed and remains within typical measurement error and variability. Simulations of ischemic mitral insufficiency are also performed. Pressure-Volume loops, transmitral flow evolution and mitral valve aperture area evolution follow reported measurements in shape, amplitude and trends. Conclusions The resulting cardiovascular system model including mitral valve dynamics provides a foundation for clinical validation and the study of valvular dysfunction in vivo. The overall models and results could readily be generalised to other cardiac valves.

  4. Analysis of Water Hammer with Different Closing Valve Laws on Transient Flow of Hydrogen-Natural Gas Mixture

    National Research Council Canada - National Science Library

    Subani, Norazlina; Amin, Norsarahaida

    2015-01-01

      Water hammer on transient flow of hydrogen-natural gas mixture in a horizontal pipeline is analysed to determine the relationship between pressure waves and different modes of closing and opening of valves...

  5. Dynamic modelling of check valves in shipping terminals; Modelagem dinamica de valvulas de retencao em terminais maritimos

    Energy Technology Data Exchange (ETDEWEB)

    Pires, Luis F.G.; Barreto, Claudio V.; Sarmento, Renata C. [Pontificia Univ. Catolica do Rio de Janeiro, RJ (Brazil). Dept. de Engenharia Mecanica. Nucleo de Simulacao Termohidraulica de Dutos (SIMDUT)

    2005-07-01

    As usual a shipping terminal contains a header and its diameter is smaller than the main pipeline diameter. This diameter reduction amplifies the effects caused by hydraulic transients. It was noticed during simulations that check valves without dynamic modeling may introduce some error in the maximum pressure results without a dynamic model approach. The current paper uses commercial pipeline simulation software to model the dynamic behavior of the check valves. It was studied the header diameter influence and how the check valve model type may change the maximum pressure in the pipeline. It was proved that even a pipeline that works with low pressure and small elevation drop needs a detailed valve modeling to prevent the calculation of unreal pressure values in the region with diameter reduction. (author)

  6. Sutureless Valves Reduce Hospital Costs Compared to Traditional Valves.

    Science.gov (United States)

    Laborde, François; Folliguet, Thierry; Ghorayeb, Gabriel; Zannis, Konstantinos

    2017-01-01

    The study aim was to assess differences in clinical outcome, safety, and associated costs between sutureless and aortic isolated aortic valve replacement (AVR) with a standard bioprosthesis. A retrospective comparative study was conducted to investigate 65 patients, each of whom had undergone isolated AVR with a traditional aortic valve (T) or a Perceval S sutureless aortic prosthesis (P) between January 2010 and December 2012. Cost data were drawn from the proprietary cost accounting system of the hospital, excluding acquisition costs of the devices. A linear regression model was used to estimate the mean total costs difference between groups. The mean cardiopulmonary bypass time and aortic cross-clamp times in the T and P groups were 80 ± 41 min and 58 ± 26 min versus 38 ± 16 min and 26 ± 10 min, respectively (p costs savings for group P compared to group T were €3,801 (p = 0.13), mainly driven by hospital stay costs. Savings between the P and T groups increased with age: €4,992 in patients aged 70-79 years and €9,326 in those aged 80+ years, and with risk (€4,296 for high-risk patients). Sutureless aortic valves present shorter procedural times and lower hospital costs compared to traditional valves, with higher cost savings at increased patient age and risk. Sutureless aortic valves seem to be cost-effective in patients undergoing AVR.

  7. Design and test of a simple fast electromagnetic inductive gas valve for planar pulsed inductive plasma thruster

    Science.gov (United States)

    Guo, Dawei; Cheng, Mousen; Li, Xiaokang

    2017-10-01

    In support of our planar pulsed inductive plasma thruster research, a fast electromagnetic inductive valve for a gas propellant injection system has been built and tested. A new and important design feature is the use of a conical diaphragm as the action part, which greatly contributes to the virtue of simplicity for adopting the resultant force of the diaphragm deformation as the closing force. An optical transmission technique is adopted to measure the opening and closing characters of the valve while the gas throughput is determined by measuring the pressure change per pulse in a test chamber with a capacitance manometer. The experimental results revealed that the delay time before the valve reaction is less than 40 μs, and the valve pulse width is no longer than 160 μs full width at half maximum. The valve delivers 0-2.5 mg of argon gas per pulse varied by adjusting the drive voltage and gas pressure.

  8. Robotically assisted mitral valve replacement.

    Science.gov (United States)

    Gao, Changqing; Yang, Ming; Xiao, Cangsong; Wang, Gang; Wu, Yang; Wang, Jiali; Li, Jiachun

    2012-04-01

    In the present study, we determined the safety and efficacy of robotic mitral valve replacement using robotic technology. From January 2007 through March 2011, more than 400 patients underwent various types of robotic cardiac surgery in our department. Of these, 22 consecutive patients underwent robotically assisted mitral valve replacement. Of the 22 patients with isolated rheumatic mitral valve stenosis (9 men and 13 women), the mean age was 44.7 ± 19.8 years (range, 32-65). Preoperatively, all patients underwent a complete workup, including coronary angiography and transthoracic echocardiography. Of the 22 patients, 15 had concomitant atrial fibrillation. The surgical approach was through 4 right-side chest ports with femoral perfusion. Aortic occlusion was performed with a Chitwood crossclamp, and antegrade cardioplegia was administered directly by way of the anterior chest. Using 3 port incisions in the right side of the chest and a 2.5- to 3.0-cm working port, all the procedures were completed with the da Vinci S robot. All patients underwent successful robotic surgery. Of the 22 patients, 16 received a mechanical valve and 6 a tissue valve. The mean cardiopulmonary bypass time and aortic crossclamp time was 137.1 ± 21.9 minutes (range, 105-168) and 99.3 ± 17.9 minutes (range, 80-133), respectively. No operative deaths, stroke, or other complications occurred, and no incisional conversions were required. After surgery, all the patients were followed up echocardiographically. Robotically assisted mitral valve replacement can be performed safely in patients with isolated mitral valve stenosis, and surgical results are excellent. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  9. What Are the Signs and Symptoms of Heart Valve Disease?

    Science.gov (United States)

    ... as well as surgery for adults who have aortic valve stenosis. Doctors often use balloon valvuloplasty to repair valve stenosis in infants and children. Replacing Heart Valves Sometimes heart valves can’t ...

  10. Suture locking of isolated internal locking knotless suture anchors is not affected by bone quality

    Science.gov (United States)

    Woodmass, Jarret M; Matthewson, Graeme; Ono, Yohei; Bois, Aaron J; Boorman, Richard S; Lo, Ian KY; Thornton, Gail M

    2015-01-01

    Purpose The purpose of this study was to evaluate the mechanical performance of different suture locking mechanisms including: i) interference fit between the anchor and the bone (eg, 4.5 mm PushLock, 5.5 mm SwiveLock), ii) internal locking mechanism within the anchor itself (eg, 5.5 mm SpeedScrew), or iii) a combination of interference fit and internal locking (eg, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Methods Anchors were tested in foam blocks representing normal (20/8 foam) or osteopenic (8/8 foam) bone, using standard suture loops pulled in-line with the anchor to isolate suture locking. Mechanical testing included cyclic testing for 500 cycles from 10 N to 60 N at 60 mm/min, followed by failure testing at 60 mm/min. Displacement after 500 cycles at 60 N, number of cycles at 3 mm displacement, load at 3 mm displacement, and maximum load were evaluated. Results Comparing 8/8 foam to 20/8 foam, load at 3 mm displacement and maximum load were significantly decreased (Panchors that, even in part, relied on an interference fit suture locking mechanism (ie, 4.5 mm PushLock, 5.5 mm SwiveLock, 4.5 mm MultiFIX P, 5.5 mm MultiFIX S). Bone quality did not affect the mechanical performance of 5.5 mm SpeedScrew anchors which have an isolated internal locking mechanism. Conclusion The mechanical performance of anchors that relied, even in part, on interference fit were affected by bone quality. Isolated internal locking knotless suture anchors functioned independently of bone quality. Anchors with a combined type (interference fit and internal locking) suture locking mechanism demonstrated similar mechanical performance to isolated internal locking anchors in osteopenic foam comparing similar sized anchors. Clinical relevance In osteopenic bone, knotless suture anchors that have an internal locking mechanism (isolated or combined type) may be advantageous for secure tendon fixation to bone. PMID:26124683

  11. Surgical phantom for off-pump mitral valve replacement

    Science.gov (United States)

    McLeod, A. Jonathan; Moore, John; Guiraudon, Gerard M.; Jones, Doug L.; Campbell, Gordon; Peters, Terry M.

    2011-03-01

    Off-pump, intracardiac, beating heart surgery has the potential to improve patient outcomes by eliminating the need for cardiopulmonary bypass and aortic cross clamping but it requires extensive image guidance as well as the development of specialized instrumentation. Previously, developments in image guidance and instrumentation were validated on either a static phantom or in vivo through porcine models. This paper describes the design and development of a surgical phantom for simulating off-pump mitral valve replacement inside the closed beating heart. The phantom allows surgical access to the mitral annulus while mimicking the pressure inside the beating heart. An image guidance system using tracked ultrasound, magnetic instrument tracking and preoperative models previously developed for off-pump mitral valve replacement is applied to the phantom. Pressure measurements and ultrasound images confirm the phantom closely mimics conditions inside the beating heart.

  12. Investigation of charges for thermostatic expansion valves containing condensable and non condensable gas

    DEFF Research Database (Denmark)

    Langmaack, Lasse Nicolai; Knudsen, Hans-Jørgen Høgaard

    2006-01-01

    The bulb of a thermostatic expansion valve (TXV) is basically a temperature-pressure converter. It senses the temperature at the outlet of the evaporator, and the substance in the bulb (charge) generates the corresponding saturation pressure inside the bulb. The aim of the work presented...

  13. Mitral valve aneurysm associated with aortic valve endocarditis and regurgitation.

    Science.gov (United States)

    Raval, Amish N; Menkis, Alan H; Boughner, Derek R

    2002-01-01

    Mitral valve aneurysms are rare complications occurring most commonly in association with aortic valve infective endocarditis. [Decroly 1989, Chua 1990, Northridge 1991, Karalis 1992, Roguin 1996, Mollod 1997, Vilacosta 1997, Cai 1999, Vilacosta 1999, Teskey 1999, Chan 2000, Goh 2000, Marcos- Alberca 2000] While the mechanism of the development of this lesion is unclear, complications such as perforation can occur and lead to significant mitral regurgitation. [Decroly 1989, Karalis 1992, Teskey 1999, Vilacosta 1999]; The case of a 69-year-old male with Streptococcus Sanguis aortic valve endocarditis and associated anterior mitral leaflet aneurysm is presented. Following surgery, tissue pathology of the excised lesion revealed myxomatous degeneration and no active endocarditis or inflammatory cells. This may add support to the hypothesis that physical stress due to severe aortic insufficiency and structural weakening, without infection of the anterior mitral leaflet, can lead to the development of this lesion.

  14. Valved stent for off-pump mitral valve replacement

    OpenAIRE

    Ma, L.(School of Physics, Shandong University, Shandong, China)

    2004-01-01

    Résumé Objectif : Evaluer un remplacement de valve mitrale hors-pompe avec des stents valvés Méthode: Des homografts préservés dans du glutaraldehyde ont été suturés dans une prothèse tubulaire avant d'être soudés à deux stents Z en nitinol pour créer deux couronnes auto- extensibles. A) Nous avons testé la valve in vitro en utilisant un circuit pulsatile fermé (mock loop) ayant de débuter les expériences sur les porcs. (n=8, 46 .0± 4.3 kg : B). L'oreillette gauche a été exposée p...

  15. Minimally Invasive Heart Valve Surgery.

    Science.gov (United States)

    Bouhout, Ismail; Morgant, Marie-Catherine; Bouchard, Denis

    2017-09-01

    Minimally invasive valve surgery represents a recent and significant advance in modern heart surgery. Indeed, many less invasive approaches for both the aortic and mitral valves have been developed in the past 2 decades. These procedures were hypothesized to result in less operative trauma, which might translate into better patient outcomes. However, this clinical benefit remains controversial in the literature. The aim of this review is to discuss the evidence surrounding minimally invasive heart valve surgery in the current era. A systematic search of the literature from 2006-2016 was performed looking for articles reporting early or late outcomes after minimally invasive valve surgery. Less invasive valve surgery is safe and provides long-term surgical outcomes similar to those of standard sternotomy. In addition, these approaches result in a reduction in overall hospital length of stay and may mitigate the risk of early morbidity-mainly postoperative bleeding, transfusions, and ventilation duration. Copyright © 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.

  16. Structural valve deterioration in the Mitroflow biological heart valve prosthesis

    DEFF Research Database (Denmark)

    Issa, Issa Farah; Poulsen, Steen Hvitfeldt; Waziri, Farhad

    2018-01-01

    OBJECTIVES: Concern has been raised regarding the long-term durability of the Mitroflow biological heart valve prosthesis. Our aim was to assess the incidence of structural valve degeneration (SVD) for the Mitroflow bioprosthesis in a nationwide study in Denmark including all patients alive...... in Denmark who had received a Mitroflow aortic bioprosthesis since 2000. METHODS: Patients alive in Denmark with a Mitroflow bioprosthesis implanted since January 2000 were invited to participate in a nationwide cross-sectional study with a predefined definition of SVD. Of 1552 patients, 861 patients had...

  17. Development of mechanical heart valves - an inspiring tale

    Directory of Open Access Journals (Sweden)

    P Rajashekar

    2015-01-01

    Full Text Available The historical evolution of the prosthetic heart valves from the first attempts with the Hufnagel′s valve in the treatment of the aortic insufficiency to the Starr-Edwards′ ball valve and later the tilting disc valves (Bjork-Shiley etc., and finally the bileaflet valves (St. Jude are discussed. The Indian contribution with Chitra valve is also described.

  18. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves

    Science.gov (United States)

    van Rensburg, Annari; Doubell, Anton

    2017-01-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P abnormal papillary muscles (P = 0.002) and an additional chord or tendon in the left ventricle cavity (P = 0.007). Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. PMID:28515127

  19. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  20. A retrospective analysis of mitral valve pathology in the setting of bicuspid aortic valves.

    Science.gov (United States)

    van Rensburg, Annari; Herbst, Philip; Doubell, Anton

    2017-06-01

    The therapeutic implications of bicuspid aortic valve associations have come under scrutiny in the transcatheter aortic valve implantation era. We evaluate the spectrum of mitral valve disease in patients with bicuspid aortic valves to determine the need for closer echocardiographic scrutiny/follow-up of the mitral valve. A retrospective analysis of echocardiograms done at a referral hospital over five years was conducted in patients with bicuspid aortic valves with special attention to congenital abnormalities of the mitral valve. One hundred and forty patients with a bicuspid aortic valve were included. A congenital mitral valve abnormality was present in eight (5.7%, P = 0.01) with a parachute mitral valve in four (2.8%), an accessory mitral valve leaflet in one (0.7%), mitral valve prolapse in one, a cleft in one and the novel finding of a trileaflet mitral valve in one. Minor abnormalities included an elongated anterior mitral valve leaflet (P mitral regurgitation (P Mitral valve abnormalities occur more commonly in patients with bicuspid aortic valves than matched healthy individuals. The study confirms that abnormalities in these patients extend beyond the aorta. These abnormalities did not have a significant functional effect. © 2017 The authors.