WorldWideScience

Sample records for valve driving cam

  1. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  2. Valve cam design using numerical step-by-step method

    OpenAIRE

    Vasilyev, Aleksandr; Bakhracheva, Yuliya; Kabore, Ousman; Zelenskiy, Yuriy

    2014-01-01

    This article studies the numerical step-by-step method of cam profile design. The results of the study are used for designing the internal combustion engine valve gear. This method allows to profile the peak efficiency of cams in view of many restrictions, connected with valve gear serviceability and reliability.

  3. Cam Drive Step Mechanism of a Quadruped Robot

    Directory of Open Access Journals (Sweden)

    Qun Sun

    2014-01-01

    Full Text Available Bionic quadruped robots received considerable worldwide research attention. For a quadruped robot walking with steady paces on a flat terrain, using a cam drive control mechanism instead of servomotors provides theoretical and practical benefits as it reduces the system weight, cost, and control complexities; thus it may be more cost beneficial for some recreational or household applications. This study explores the robot step mechanism including the leg and cam drive control systems based on studying the bone structure and the kinematic step sequences of dog. The design requirements for the cam drive robot legs have been raised, and the mechanical principles of the leg operating mechanism as well as the control parameters have been analyzed. A cam drive control system was constructed using three cams to control each leg. Finally, a four-leg demo robot was manufactured for experiments and it showed stable walking patterns on a flat floor.

  4. Fiber-optical switch using cam-micromotor driven by scratch drive actuators

    Science.gov (United States)

    Kanamori, Y.; Aoki, Y.; Sasaki, M.; Hosoya, H.; Wada, A.; Hane, K.

    2005-01-01

    We fabricated a 1 × 1 fiber-optic switch using a cam-micromotor driven by scratch drive actuators (SDAs). Using the cam-micromotor, mechanical translation and precise positioning of an optical fiber were performed. An optical fiber of diameter 50 µm was bent and pushed out with a cam-mechanism driven by the SDAs fabricated by surface micromachining. The maximum rotation speed of the cam-micromotor was 7.5 rpm at a driving frequency of 1.5 kHz. The transient time of the switch to attenuate coupling efficiency less than -40 dB was around 10 ms.

  5. Study on a new type variable valve lift timing mechanism with a three dimensional cam; Sanjigen cam ni yoru shinkahen valve lift timing kiko ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Ogura, M; Song, C [Nippon Institute of Technology, Saitama (Japan)

    1997-10-01

    The variable valve timing mechanism was invented to get a torque band at wide engine speed, and to reduce a compression job and pumping loss by a miler cycle at partial load. In this paper, the new type variable valve timing mechanism applying a three dimensional cam was proposed. Also, the feature of mechanism and the control system was done obviously. Further, about a miler cycle, a thermodynamics -like consideration was described. 5 refs., 8 figs.

  6. Drive piston assembly for a valve actuator assembly

    Science.gov (United States)

    Sun, Zongxuan

    2010-02-23

    A drive piston assembly is provided that is operable to selectively open a poppet valve. The drive piston assembly includes a cartridge defining a generally stepped bore. A drive piston is movable within the generally stepped bore and a boost sleeve is coaxially disposed with respect to the drive piston. A main fluid chamber is at least partially defined by the generally stepped bore, drive piston, and boost sleeve. First and second feedback chambers are at least partially defined by the drive piston and each are disposed at opposite ends of the drive piston. At least one of the drive piston and the boost sleeve is sufficiently configured to move within the generally stepped bore in response to fluid pressure within the main fluid chamber to selectively open the poppet valve. A valve actuator assembly and engine are also provided incorporating the disclosed drive piston assembly.

  7. BWR control rod drive scram pilot valve monitoring system

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1984-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechancial works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the ''insert'' side of the control rod piston and vents the ''withdraw'' side of the piston causing the rods to insert during a scam. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a ''half scram'', a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  8. BWR control rod drive scram pilot valve monitoring program

    International Nuclear Information System (INIS)

    Soden, R.A.; Kelly, V.

    1986-01-01

    The control rod drive system in a Boiling Water Reactor is the most important safety system in the power plant. All components of the system can be verified except the solenoid operated, scram pilot valves without scramming a rod. The pilot valve mechanical works is the weak link to the control rod drive system. These pilot valves control the hydraulic system which applies pressure to the insert side of the control rod piston and vents the withdraw side of the piston causing the rods to insert during a scram. The only verification that the valve is operating properly is to scram the rod. The concern for this portion of the system is demonstrated by the high number of redundant components and complete periodic testing of the electrical circuits. The pilot valve can become hung-up through wear, fracture of internal components, mechanical binding, foreign material or chemicals left in the valve during maintenance, etc. If the valve becomes hung-up the electrical tests performed will not indicate this condition and scramming the rod is in jeopardy. Only an attempt to scram a rod will indicate the hung-up valve. While this condition exists the rod is considered inoperative. This paper describes a system developed at a nuclear power plant that monitors the pilot valves on the control rod drive system. This system utilizes pattern recognition to assure proper internal workings of the scram pilot valves to plant operators. The system is totally automatic such that each time the valve is operated on a half scram, a printout is available to the operator along with light indication that each of the 370 valves (on one unit of a BWR) is operating properly. With this monitoring system installed, all components of the control rod drive system including the solenoid pilot valves can be verified as operational without scramming any rods

  9. An Analytic Approach to Cascade Control Design for Hydraulic Valve-Cylinder Drives

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Hansen, Anders Hedegaard; Andersen, Torben O.

    2016-01-01

    , unfortunately not present in valve-operated hydraulic drives. This paper considers a cascade control approach for hydraulic valve-cylinder drives motivated by the fact that this may be applied to successfully suppress nonlinearities. The drive is pre-compensated utilizing a pressure updated inverse valve flow...

  10. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Sung Tae; Park, Jin Ho; Choi, Yoon Dong; Choi, Jong Hyun; Cho, Byung Ryeol; Kim, Tae Jun; Moon, Byung Hwan; Hong, Soon Bok; Jeong, Ji Young

    1995-09-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; 1. Study on the radial rays effecting to the permanent magnets -Measurement of the strength of Nd-magnets according to irradiation of radial rays. 2. Effects of temperature on the magnetic driving device -Temperature dependency of the Nd-casting magnets. -Effects of temperature on the heat releasing fins of high-temperature valve. 3. Optimization of torque -Arranging method of permanent magnets -Measuring method and results of torque. 4. Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Calculation and design for the flat circular plates under pressure of the magnetic power transmitting device -Design, manufacture and test for the pressure-resisting structure of magnetic power transmitting device -Comparison of the characteristics between magnetic drive valve and general/bellows-sealed valves. 5. Pressure test and strength analysis of flat circular plates under pressure. 6. Patent application. 12 tabs., 24 figs., 1 ref. (Author)

  11. Detection circuit of solenoid valve operation and control rod drive mechanism utilizing the circuit

    International Nuclear Information System (INIS)

    Ono, Takehiko.

    1976-01-01

    Object: To detect the operation of a plunger and detect opening and closing operations of a solenoid valve driving device due to change in impedance of a coil for driving the solenoid valve to judge normality and abnormality of the solenoid valve, thereby increasing reliance and safety of drive and control apparatus of control rods. Structure: An arrangement comprises a drive and operation detector section wherein the operation of a solenoid driving device for controlling power supply to a coil for driving the solenoid valve to control opening and closing of the solenoid valve, and a plunger operation detector section for detecting change in impedance of the drive coil to detect that the plunger of the solenoid valve is either in the opening direction or closing direction, whereby a predetermined low voltage such as not to activate the solenoid valve even when the solenoid valve is open or closed is applied to detect a current flowing into the coil at that time, thus detecting an operating state of the plunger. (Yoshino, Y.)

  12. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Sung Tai; Choi, J. H.; Jeong, K. C.; Jeong, J. Y.; Choi, Y. D.; Kwon, S. W.; Kim, B. H.

    1997-01-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows: 1) characteristics and principle of the valve 2) study on the radial rays effecting to the permanent magnets 3) effects of temperature on the magnetic driving device a) temperature-dependency of the Nd-casting magnets b) effects of temperature on the heat releasing fins of high-temperature valve 4) optimization of torque a) arranging method of permanent magnets b) measuring method and results of torque 5) enlargement of magnetic rotating force a) experiments for the torque enlargement 6) calculation and pressure test for the pressure-resisting structure of magnetic power transmitting device a) calculation for the flat circular plates under pressure b) pressure test of the separating plate 7) design and manufacture of the valve 8) patent application. (author). 1 ref., 18 tabs., 38 figs

  13. Development of magnetic drive packless valves for commercial purpose

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Seong Tae; Choi, Yoon Dong; Jeong, Ji Young [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1995-12-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; A. Maximization of torque (1) Arranging method of magnets (2) Effects on the distance between magnetic holders (3) Improvement of the valve disc for the torque maximization. B. Study on the high pressure structure of the valve (1) Analysis of the pressure-resisting structure of the magnetic power transmitting device (2) Calculation model and program (a) Calculation model (b) Program used in calculation (3) Structure analysis and verification test for the pressurized plate. C. Study on the valve compacting. D. Technical specification for the valve manufacture. E. Inspection and test method for valve. 10 tabs., 10 figs. (Author).

  14. Development of magnetic drive packless valves for commercial purpose

    International Nuclear Information System (INIS)

    Hwang, Seong Tae; Choi, Yoon Dong; Jeong, Ji Young

    1995-12-01

    A study on development of magnetic drive packless valves for commercial purpose showed the results as follows; A. Maximization of torque (1) Arranging method of magnets (2) Effects on the distance between magnetic holders (3) Improvement of the valve disc for the torque maximization. B. Study on the high pressure structure of the valve (1) Analysis of the pressure-resisting structure of the magnetic power transmitting device (2) Calculation model and program (a) Calculation model (b) Program used in calculation (3) Structure analysis and verification test for the pressurized plate. C. Study on the valve compacting. D. Technical specification for the valve manufacture. E. Inspection and test method for valve. 10 tabs., 10 figs. (Author)

  15. A Generic Model Based Tracking Controller for Hydraulic Valve-Cylinder Drives

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Schmidt, Lasse; Pedersen, Henrik Clemmensen

    2016-01-01

    in the entire range of operation, rather than reducing stationary errors, and may be parameterized from the desired gain margin, as well as linear model parameters. The proposed control design approaches are evaluated in an experimentally validated, nonlinear simulation model of a hydraulic valve-cylinder drive......The control of hydraulic valve-cylinder drives is still an active subject of research, and various linear and particularly nonlinear approaches has been proposed, especially in the last two-three decades. In many cases the proposed controllers appear to produce excellent tracking ability due...... generally has failed to break through in industry. This paper discusses the dominant properties necessary to take into account when considering position tracking control of hydraulic valve-cylinder drives, and presents two generally applicable, generic control design approaches that combines non...

  16. Camshaft bearing arrangement for overhead cam engine

    Energy Technology Data Exchange (ETDEWEB)

    Yoshikawa, M.

    1985-01-01

    In an assembly for an internal combustion engine comprising a cylinder block, a cylinder head detachably affixed to the cylinder block by a plurality of threaded fastening means, a plurality of poppet valves supported for reciprocation in the cylinder head and a camshaft for operating the poppet valves, the improvement is described comprising a cam carrier detachably affixed to the cylinder head and overlying the threaded fastening means, and a bearing cap affixed to the cam carrier. The cam carrier and the bearing cap have bearing surfaces for journaling the camshaft.

  17. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  18. Gasoline New Timing and Flux Adjustable Rotary Valve Design (Hereinafter: Rotary Valve

    Directory of Open Access Journals (Sweden)

    Du huiqi

    2016-01-01

    Full Text Available Conventional gasoline engine with an umbrella valve control cylinder intake and exhaust, in order to achieve sealing effect, the valve is driven by the spring force; at the same time, when the cam opens the valve to overcome the spring force acting. Sealing the better, the more power consumed in the engine mechanical losses, the valve mechanism consumes about 30%, which is not a small loss! This article describes a new type of rotary valve is to significantly reduce mechanical losses, so as to achieve energy saving purposes.

  19. Engine testing of ceramic cam-roller followers

    Energy Technology Data Exchange (ETDEWEB)

    Kalish, Y. (Detroit Diesel Corp., MI (United States))

    1992-04-01

    For several years, DDC has been developing monolithic ceramic heat engine components. One of the components, developed for an application in our state-of-the-art on-highway, heavy-duty diesel engine, the Series 60, is a silicon nitride cam-roller follower. Prior to starting this program, each valve train component in the Series 60 was considered for conversion to a ceramic material. Many advantages and disadvantages (benefits and risks) were considered. From this effort, one component was selected, the cam-roller follower. Using a system design approach, a ceramic cam-roller follower offered functional improvement at a reasonable cost. The purpose of the project was to inspect and test 100 domestically produced silicon nitride cam-roller followers built to the requirements of the DDC series 60 engine.

  20. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig...

  1. Motion and Stress Analysis of Cam System for Marine Diesel Engine 93 KW

    Directory of Open Access Journals (Sweden)

    Christian Dhani Setiawan

    2017-01-01

    Full Text Available The developments of maritime sector in Indonesia shows increasing demand for ships. Especially ships with size of 30 GT has problem with low availability of the ship engine, which most of the ships still use non marine diesel engine as its main propulsion. The problem gives interest to make a step to improve by design marine diesel engine using reverse engineering method. Cam system of marine diesel engine design was needed to be calculate to select the material and the motion. The design of cam system needs study about the stress analysis in cam system to make sure the distribution of force and moment. The result of stress analysis was used to select material of components in cam system. The motion analysis result was used to be input data of stress analysis. The condition to obtain the stress of components was on maximum condition, its contain pressure, torque, rotation, and force. All component that calculated are camshaft, lifter (flat-tappet, push rod, rocker arm, spring, and valve. Each component was given two different materials and material selection was based on safety factor of each component. Material for camshaft and lifter were malleable cast iron, for push rod and rocker arm were mild steel, for spring was ASTM A231, for intake valve was steel JIS SUH3, and for exhaust valve was steel JIS SUH35. The result of motion analysis were angular velocity of camshaft with value was 2400 deg/sec, friction force between camshaft and lifter with maximum value was 125.393 N, and contact force between camshaft and lifter with maximum value was 845.307 N, and linear velocity of intake valve with maximum value was 696.573 mm/s, and linear velocity of exhaust valve was 463.734 mm/s.

  2. Excitatory Synaptic Drive and Feedforward Inhibition in the Hippocampal CA3 Circuit Are Regulated by SynCAM 1.

    Science.gov (United States)

    Park, Kellie A; Ribic, Adema; Laage Gaupp, Fabian M; Coman, Daniel; Huang, Yuegao; Dulla, Chris G; Hyder, Fahmeed; Biederer, Thomas

    2016-07-13

    Select adhesion proteins control the development of synapses and modulate their structural and functional properties. Despite these important roles, the extent to which different synapse-organizing mechanisms act across brain regions to establish connectivity and regulate network properties is incompletely understood. Further, their functional roles in different neuronal populations remain to be defined. Here, we applied diffusion tensor imaging (DTI), a modality of magnetic resonance imaging (MRI), to map connectivity changes in knock-out (KO) mice lacking the synaptogenic cell adhesion protein SynCAM 1. This identified reduced fractional anisotropy in the hippocampal CA3 area in absence of SynCAM 1. In agreement, mossy fiber refinement in CA3 was impaired in SynCAM 1 KO mice. Mossy fibers make excitatory inputs onto postsynaptic specializations of CA3 pyramidal neurons termed thorny excrescences and these structures were smaller in the absence of SynCAM 1. However, the most prevalent targets of mossy fibers are GABAergic interneurons and SynCAM 1 loss unexpectedly reduced the number of excitatory terminals onto parvalbumin (PV)-positive interneurons in CA3. SynCAM 1 KO mice additionally exhibited lower postsynaptic GluA1 expression in these PV-positive interneurons. These synaptic imbalances in SynCAM 1 KO mice resulted in CA3 disinhibition, in agreement with reduced feedforward inhibition in this network in the absence of SynCAM 1-dependent excitatory drive onto interneurons. In turn, mice lacking SynCAM 1 were impaired in memory tasks involving CA3. Our results support that SynCAM 1 modulates excitatory mossy fiber inputs onto both interneurons and principal neurons in the hippocampal CA3 area to balance network excitability. This study advances our understanding of synapse-organizing mechanisms on two levels. First, the data support that synaptogenic proteins guide connectivity and can function in distinct brain regions even if they are expressed broadly

  3. Cam-Follower Mechanism Design for Narrow Loom Beat Up Motion ...

    African Journals Online (AJOL)

    The topology of the kinematics is developed by using the graph theory method of kinematic synthesis. The forces required to drive the plate-cam and follower system were modeled and the components such as the plate-cam, camshaft, the follower and the drive mechanism were synthesized for smooth operation of the ...

  4. Engine testing of ceramic cam-roller followers. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Kalish, Y. [Detroit Diesel Corp., MI (United States)

    1992-04-01

    For several years, DDC has been developing monolithic ceramic heat engine components. One of the components, developed for an application in our state-of-the-art on-highway, heavy-duty diesel engine, the Series 60, is a silicon nitride cam-roller follower. Prior to starting this program, each valve train component in the Series 60 was considered for conversion to a ceramic material. Many advantages and disadvantages (benefits and risks) were considered. From this effort, one component was selected, the cam-roller follower. Using a system design approach, a ceramic cam-roller follower offered functional improvement at a reasonable cost. The purpose of the project was to inspect and test 100 domestically produced silicon nitride cam-roller followers built to the requirements of the DDC series 60 engine.

  5. Design and Evaluation of a Direct Drive Valve Actuated by Piezostack Actuator

    Directory of Open Access Journals (Sweden)

    Juncheol Jeon

    2013-01-01

    Full Text Available This paper presents performance characteristics of a new type of direct drive valve (DDV system driven by a piezostack actuator. The flexible beam mechanism is employed to amplify the output displacement from the piezostack actuator. After describing the operational principle of the proposed piezo DDV system, the governing equation of the whole piezo DDV system is then obtained by integrating the equations of the valve components. Based on the proposed model, significant structural components of the piezo DDV system are designed in order to achieve operational requirements (operating frequency: over 100 Hz; flow rate: 20 liter/Min.. An optimal design method is proposed for obtaining the geometry of the flexible beam mechanism by considering spool displacement, required operating frequency, and available space of the valve. After deciding the specific geometric dimensions of the piezo DDV system, a PID control algorithm is designed to enforce the spool position to the desired position trajectories by activating the piezostack actuator. Characteristics and control performances of the proposed piezo DDV system are evaluated using the MATLAB Simulink.

  6. An analysis of valve train behavior considering stiffness effects

    International Nuclear Information System (INIS)

    Chun, Dong Joon; Lee, Jin Kab

    2000-01-01

    To maintain the specific volumetric efficiency of a heavy-duty diesel engine, an understanding of the behavior of each part of the valve train system is very important. The stiffness of the valve train system has a strong influence on the behavior of the valve train than value clearance, heat-resistance, or the durability of parts. In this study, a geometrical cam design profile using a finite element model of the valve train system is suggested. The results of the valve behavior according to the change in stiffness is analyzed for further tuning of the valve train system

  7. Experimental Study on Revetec Engine Cam Performance

    International Nuclear Information System (INIS)

    Gasim, Maisara Mohyeldin; Chui, Lee Giok; Anwar, Khirul Azhar bin

    2012-01-01

    In Revetec engine (three-lobed) cam replaces the crankshaft to convert the reciprocating motion of the engine piston, to a rotating motion in the drive line. Since the cam controls the piston movement, the cam profile has a great effect on engine performance. In this paper an experimental study was done to a (three- lobed) cam with Cycloidal motion profile but with different ratios between the base circle radius of the cam and the radius of the roller follower. DEWESoft was used to find the displacement and the vibration of the piston, and compare the actual results from the test with the theoretical results from the cam profile equation. The results showed that there is a periods of miss contact between the follower and the cam when the ratio between the base circle radius of the cam and the radius of the roller follower is less than a certain value, and also increasing of vibration. The suggested ratio between the cam and follower radius is to be more than 2:1.

  8. Control rod drives

    International Nuclear Information System (INIS)

    Futatsugi, Masao.

    1980-01-01

    Purpose: To secure the reactor operation safety by the provision of a fluid pressure detecting section for control rod driving fluid and a control rod interlock at the midway of the flow pass for supplying driving fluid to the control rod drives. Constitution: Between a driving line and a direction control valve are provided a pressure detecting portion, an alarm generating device, and a control rod inhibition interlock. The driving fluid from a driving fluid source is discharged by way of a pump and a manual valve into the reactor in which the control rods and reactor fuels are contained. In addition, when the direction control valve is switched and the control rods are inserted and extracted by the control rod drives, the pressure in the driving line is always detected by the pressure detection section, whereby if abnormal pressure is resulted, the alarm generating device is actuated to warn the abnormality and the control rod inhibition interlock is actuated to lock the direction control valve thereby secure the safety operation of the reactor. (Seki, T.)

  9. The application of CAD, CAE & CAM in development of butterfly valve’s disc

    Science.gov (United States)

    Asiff Razif Shah Ranjit, Muhammad; Hanie Abdullah, Nazlin

    2017-06-01

    The improved design of a butterfly valve disc is based on the concept of sandwich theory. Butterfly valves are mostly used in various industries such as oil and gas plant. The primary failure modes for valves are indented disc, keyways and shaft failure and the cavitation damage. Emphasis on the application of CAD, a new model of the butterfly valve’s disc structure was designed. The structure analysis was analysed using the finite element analysis. Butterfly valve performance factors can be obtained is by using Computational Fluid Dynamics (CFD) software to simulate the physics of fluid flow in a piping system around a butterfly valve. A comparison analysis was done using the finite element to justify the performance of the structure. The second application of CAE is the computational fluid flow analysis. The upstream pressure and the downstream pressure was analysed to calculate the cavitation index and determine the performance throughout each opening position of the valve. The CAM process was done using 3D printer to produce a prototype and analysed the structure in form of prototype. The structure was downscale fabricated based on the model designed initially through the application of CAD. This study is utilized the application of CAD, CAE and CAM for a better improvement of the butterfly valve’s disc components.

  10. Control performances of a piezoactuator direct drive valve system at high temperatures with thermal insulation

    Science.gov (United States)

    Han, Yung-Min; Han, Chulhee; Kim, Wan Ho; Seong, Ho Yong; Choi, Seung-Bok

    2016-09-01

    This technical note presents control performances of a piezoactuator direct drive valve (PDDV) operated at high temperature environment. After briefly discussing operating principle and mechanical dimensions of the proposed PDDV, an appropriate size of the PDDV is manufactured. As a first step, the temperature effect on the valve performance is experimentally investigated by measuring the spool displacement at various temperatures. Subsequently, the PDDV is thermally insulated using aerogel and installed in a large-size heat chamber in which the pneumatic-hydraulic cylinders and sensors are equipped. A proportional-integral-derivative feedback controller is then designed and implemented to control the spool displacement of the valve system. In this work, the spool displacement is chosen as a control variable since it is directly related to the flow rate of the valve system. Three different sinusoidal displacements with different frequencies of 1, 10 and 50 Hz are used as reference spool displacement and tracking controls are undertaken up to 150 °C. It is shown that the proposed PDDV with the thermal insulation can provide favorable control responses without significant tracking errors at high temperatures.

  11. A study of fluid flow and combustion with variable valve timing

    Energy Technology Data Exchange (ETDEWEB)

    Soederberg, F

    1998-10-01

    The effects of variable valve timing (VVT) were examined by in-cylinder Laser Doppler Velocimetry flow measurements and heat-release calculations. A single-cylinder Volvo B5254 engine was used for all experiments and the valve timing was altered by phasing or exchanging the camshaft. Special cam lobes were developed for simulation of throttle-less operation. With the standard double camshaft, a tumbling flow was generated and with valve deactivation, a swirling flow was generated. The turbulence was increased with valve deactivation. This increased the combustion rate making lean burn possible. The standard camshaft with inlet valve deactivation and late cam phasing had a faster combustion at {lambda} = 1.8 than the standard camshaft with normal cam phasing at {lambda} = 1.0. Early and late inlet valve closing was used for enabling throttle-less operation. Early inlet valve closing (EIVC) generated a very slow tumble with low turbulence. Late inlet valve closing generated both very high and low turbulence. The net indicated efficiency was improved with up to 10%. Some reduction was observed for the gross indicated efficiency, due to a too large reduction in effective compression ratio. A very stable combustion was obtained for EIVC with gasoline, possibly due to a sheering flow over the inlet valves resulting in improved fuel-air preparation. Wavelet analysis was used for dividing LDV flow measurements into time and frequency resolved information. The technique rendered the same flow results as the moving window technique, but with a separation of the turbulence into different frequencies. The choice of wavelet was shown not to be crucial. The frequency resolved turbulence was studied for tumble and swirl. A tumbling flow had a larger transfer of energy from low frequency turbulence into high frequency turbulence than a swirling flow. This is caused by the tumble breakdown. A correlation against heat-release indicated that high frequency turbulence have a larger

  12. Synthesis of sequential control algorithms for pneumatic drives controlled by monostable valves

    Directory of Open Access Journals (Sweden)

    Ł. Dworzak

    2009-07-01

    Full Text Available Application of the Grafpol method [1] for synthesising sequential control algorithms for pneumatic drives controlled by monostable valves is presented. The developed principles simplify the MTS method of programming production processes in the scope of the memory realisation [2]. Thanks to this, time for synthesising the schematic equation can be significantly reduced in comparison to the network transformation method [3]. The designed schematic equation makes a ground for writing an application program of a PLC using any language defined in IEC 61131-3.

  13. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  14. Control rod drive

    International Nuclear Information System (INIS)

    Okutani, Tetsuro.

    1988-01-01

    Purpose: To provide a simple and economical control rod drive using a control circuit requiring no pulse circuit. Constitution: Control rods in a BWR type reactor are driven by hydraulic pressure and inserted or withdrawn in the direction of applying the hydraulic pressure. The direction of the hydraulic pressure is controlled by a direction control valve. Since the driving for the control rod is extremely important in view of the operation, a self diagnosis function is disposed for rapid inspection of possible abnormality. In the present invention, two driving contacts are disposed each by one between the both ends of a solenoid valve of the direction control valve for driving the control rod and the driving power source, and diagnosis is conducted by alternately operating them. Therefore, since it is only necessary that the control circuit issues a driving instruction only to one of the two driving contacts, the pulse circuit is no more required. Further, since the control rod driving is conducted upon alignment of the two driving instructions, the reliability of the control rod drive can be improved. (Horiuchi, T.)

  15. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  16. Application of second order sliding mode algorithms for output feedback control in hydraulic cylinder drives with profound valve dynamics

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben O.

    2016-01-01

    The application of second order sliding mode algorithms for output feedback control in hydraulic valve-cylinder drives appear attractive due to their simple realization and parametrization, and strong robustness toward bounded parameter variations and uncertainties. However, intrinsic nonlinear...

  17. Evolution of CAM and C4 carbon-concentrating mechanisms

    Science.gov (United States)

    Keeley, Jon E.; Rundel, Philip W.

    2003-01-01

    Mechanisms for concentrating carbon around the Rubisco enzyme, which drives the carbon-reducing steps in photosynthesis, are widespread in plants; in vascular plants they are known as crassulacean acid metabolism (CAM) and C4 photosynthesis. CAM is common in desert succulents, tropical epiphytes, and aquatic plants and is characterized by nighttime fixation of CO2. The proximal selective factor driving the evolution of this CO2-concentrating pathway is low daytime CO2, which results from the unusual reverse stomatal behavior of terrestrial CAM species or from patterns of ambient CO2 availability for aquatic CAM species. In terrestrials the ultimate selective factor is water stress that has selected for increased water use efficiency. In aquatics the ultimate selective factor is diel fluctuations in CO2 availability for palustrine species and extreme oligotrophic conditions for lacustrine species. C4 photosynthesis is based on similar biochemistry but carboxylation steps are spatially separated in the leaf rather than temporally as in CAM. This biochemical pathway is most commonly associated with a specialized leaf anatomy known as Kranz anatomy; however, there are exceptions. The ultimate selective factor driving the evolution of this pathway is excessively high photorespiration that inhibits normal C3 photosynthesis under high light and high temperature in both terrestrial and aquatic habitats. CAM is an ancient pathway that likely has been present since the Paleozoic era in aquatic species from shallow-water palustrine habitats. While atmospheric CO2 levels have undoubtedly affected the evolution of terrestrial plant carbon-concentrating mechanisms, there is reason to believe that past atmospheric changes have not played as important a selective role in the aquatic milieu since palustrine habitats today are not generally carbon sinks, and the selective factors driving aquatic CAM are autogenic. Terrestrial CAM, in contrast, is of increasing selective value under

  18. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  19. Hydraulic system for the drive of control rod

    International Nuclear Information System (INIS)

    Niwano, Masao.

    1978-01-01

    Purpose: To remove thermal stress and improve safety by utilizing water discharged a driving device as a part of cooling water for the device upon driving of control rods. Constitution: A water drain valve is wholly closed and a flow stabilization valve is supplied with an amount of water necessary for driving control rods. Upon driving one control rod, an amount of water required for the driving is caused to flow to the relivant hydraulic control unit and the flow rate in the stabilization valve is reduced by an amount required for the driving to keep the flow rate constant in the flow control valve. Since Excess water conventionally returned to the pressure vessel is utilized as cooling water for the driving device of control rods, the pressure vessel nozzle can be saved. Accordingly, the thermal stress in the nozzle portion can be removed to significantly improve the safety. (Seki, T.)

  20. Miniature piezo electric vacuum inlet valve

    Science.gov (United States)

    Keville, Robert F.; Dietrich, Daniel D.

    1998-03-24

    A miniature piezo electric vacuum inlet valve having a fast pulse rate and is battery operated with variable flow capability. The low power (piezo electric valves which require preloading of the crystal drive mechanism and 120 Vac, thus the valve of the present invention is smaller by a factor of three.

  1. Investigation on the Effects of Internal EGR by Variable Exhaust Valve Actuation with Post Injection on Auto-ignited Combustion and Emission Performance

    Directory of Open Access Journals (Sweden)

    Insu Cho

    2018-04-01

    Full Text Available Variable valve mechanisms are usually applied to a gasoline combustion engine to improve its power performance by controlling the amount of intake air according to the operating load. These mechanisms offer one possibility of resolving the conflict of objectives between a further reduction of raw emissions and an improvement in fuel efficiency. In recent years, variable valve control systems have become extremely important in the diesel combustion engine. Importantly, it has been shown that there are several potential benefits of applying variable valve timing (VVT to a compression ignition engine. Valve train variability could offer one option to achieve the reduction goals of engine-out emissions and fuel consumption. The aim of this study was to investigate the effects on part load combustion and emission performance of internal exhaust gas recirculation (EGR by variable exhaust valve lift actuation using a cam-in-cam system, which is an electronically variable valve device with a variable inside cam retarded to about 30 degrees. Numerical simulation based on GT-POWER has been performed to predict the NOx reduction strategy at the part load operating point of 1200 rpm in a four-valve diesel engine. A GT-POWER model of a common-rail direct injection engine with internal EGR was built and verified with experimental data. As a result, large potential for reducing NOx emissions through the use of exhaust valve control has been identified. Namely, it is possible to utilize heat efficiently as recompression of retarded post injection with downscaled specification of the exhaust valve rather than the intake valve, even if the CIC V1 condition with a reduction of the exhaust valve has a higher internal EGR rate of about 2% compared to that of the CIC V2 condition.

  2. Hydraulic High Pressure Valve Controller Using the In-Situ Pressure Difference

    Science.gov (United States)

    Bao, Xiaoqi (Inventor); Sherrit, Stewart (Inventor); Badescu, Mircea (Inventor); Bar-Cohen, Yoseph (Inventor); Hall, Jeffery L. (Inventor)

    2016-01-01

    A hydraulic valve controller that uses an existing pressure differential as some or all of the power source for valve operation. In a high pressure environment, such as downhole in an oil or gas well, the pressure differential between the inside of a pipe and the outside of the pipe may be adequately large to drive a linear slide valve. The valve is operated hydraulically by a piston in a bore. When a higher pressure is applied to one end of the bore and a lower pressure to the other end, the piston moves in response to the pressure differential and drives a valve attached to it. If the pressure differential is too small to drive the piston at a sufficiently high speed, a pump is provided to generate a larger pressure differential to be applied. The apparatus is conveniently constructed using multiport valves, which can be rotary valves.

  3. Experimental research of flow servo-valve

    Science.gov (United States)

    Takosoglu, Jakub

    Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  4. All-organic polymer-dispersed liquid crystal light-valves integrated with electroactive anthraquinone-2-sulfonate-doped polypyrrole thin films as driving electrodes

    International Nuclear Information System (INIS)

    Wang, Pen-Cheng; Yu, Jing-Yu; Li, Kuan-Hsun

    2011-01-01

    Highlights: → Fabrication of flexible semi-transparent all-polymer electrodes under ambient conditions without using a CVD system. → Characterization of the above electrodes based on anthraquinone-2-sulfonate-doped polypyrrole thin films. → Demonstration of all-organic liquid crystal light-valves with polypyrrole thin films as the driving electrodes. - Abstract: All-organic PDLC (polymer-dispersed liquid crystal) light-valves using all-polymer conductive substrates containing thin films of polypyrrole doped with anthraquinone-2-sulfonate (AQSA - ) as the driving electrodes were fabricated in this study. The all-polymer conductive substrates were prepared under ambient conditions by in situ depositing polypyrrole thin films on blank flexible poly(ethylene terephthalate), or PET, substrates from aqueous media in which oxidative polymerization of pyrrole was taking place. The obtained flexible all-polymer conductive substrates were semi-transparent with cohesive coatings of AQSA - doped polypyrrole thin films (thickness ∼55 nm). The all-polymer flexible conductive substrates had sheet resistivity ∼40 kΩ □ -1 and T% transparency against air ∼78% at 600 nm. The light-valves fabricated using the above all-polymer conductive substrates showed ∼50% transparency against air at 600 nm when 4 V μm -1 electric field was applied.

  5. Experimental research of flow servo-valve

    Directory of Open Access Journals (Sweden)

    Takosoglu Jakub

    2017-01-01

    Full Text Available Positional control of pneumatic drives is particularly important in pneumatic systems. Some methods of positioning pneumatic cylinders for changeover and tracking control are known. Choking method is the most development-oriented and has the greatest potential. An optimal and effective method, particularly when applied to pneumatic drives, has been searched for a long time. Sophisticated control systems with algorithms utilizing artificial intelligence methods are designed therefor. In order to design the control algorithm, knowledge about real parameters of servo-valves used in control systems of electro-pneumatic servo-drives is required. The paper presents the experimental research of flow servo-valve.

  6. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  7. Low Load Limit Extension for Gasoline Compression Ignition Using Negative Valve Overlap Strategy

    KAUST Repository

    Vallinayagam, R.

    2018-04-03

    Gasoline compression ignition (GCI) is widely studied for the benefits of simultaneous reduction in nitrogen oxide (NO) and soot emissions without compromising the engine efficiency. Despite this advantage, the operational range for GCI is not widely expanded, as the auto-ignition of fuel at low load condition is difficult. The present study aims to extend the low load operational limit for GCI using negative valve overlap (NVO) strategy. The engine used for the current experimentation is a single cylinder diesel engine that runs at an idle speed of 800 rpm with a compression ratio of 17.3. The engine is operated at homogeneous charge compression ignition (HCCI) and partially premixed combustion (PPC) combustion modes with the corresponding start of injection (SOI) at 180 CAD (aTDC) and 30 CAD (aTDC), respectively. In the presented work, intake air temperature is used as control parameter to maintain combustion stability at idle and low load condition, while the intake air pressure is maintained at 1 bar (ambient). The engine is equipped with variable valve cam phasers that can phase both inlet and exhaust valves from the original timing. For the maximum cam phasing range (56 CAD) at a valve lift of 0.3 mm, the maximum allowable positive valve overlap was 20 CAD. In the present study, the exhaust cam is phased to 26 CAD and 6 CAD and the corresponding NVO is noted to be 10 CAD and 30 CAD, respectively. With exhaust cam phasing adjustment, the exhaust valve is closed early to retain hot residual gases inside the cylinder. As such, the in-cylinder temperature is increased and a reduction in the required intake air temperature to control combustion phasing is possible. For a constant combustion phasing of 3 CAD (aTDC), a minimum load of indicated mean effective pressure (IMEP) = 1 bar is attained for gasoline (RON = 91) at HCCI and PPC modes. The coefficient of variance was observed to below 5% at these idle and low load conditions. At the minimum load point, the

  8. The path to CAM6: coupled simulations with CAM5.4 and CAM5.5

    Science.gov (United States)

    Bogenschutz, Peter A.; Gettelman, Andrew; Hannay, Cecile; Larson, Vincent E.; Neale, Richard B.; Craig, Cheryl; Chen, Chih-Chieh

    2018-01-01

    This paper documents coupled simulations of two developmental versions of the Community Atmosphere Model (CAM) towards CAM6. The configuration called CAM5.4 introduces new microphysics, aerosol, and ice nucleation changes, among others to CAM. The CAM5.5 configuration represents a more radical departure, as it uses an assumed probability density function (PDF)-based unified cloud parameterization to replace the turbulence, shallow convection, and warm cloud macrophysics in CAM. This assumed PDF method has been widely used in the last decade in atmosphere-only climate simulations but has never been documented in coupled mode. Here, we compare the simulated coupled climates of CAM5.4 and CAM5.5 and compare them to the control coupled simulation produced by CAM5.3. We find that CAM5.5 has lower cloud forcing biases when compared to the control simulations. Improvements are also seen in the simulated amplitude of the Niño-3.4 index, an improved representation of the diurnal cycle of precipitation, subtropical surface wind stresses, and double Intertropical Convergence Zone biases. Degradations are seen in Amazon precipitation as well as slightly colder sea surface temperatures and thinner Arctic sea ice. Simulation of the 20th century results in a credible simulation that ends slightly colder than the control coupled simulation. The authors find this is due to aerosol indirect effects that are slightly stronger in the new version of the model and propose a solution to ameliorate this. Overall, in these early coupled simulations, CAM5.5 produces a credible climate that is appropriate for science applications and is ready for integration into the National Center for Atmospheric Research's (NCAR's) next-generation climate model.

  9. A study on flow distribution for integrated hybrid actuator by analysis of reed valve

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jang Mi; Kang, Seung Hwan; Ko, Han Seo [Sungkyunkwan University, Suwon (Korea, Republic of); Goo, Nam Seo; Li, Yong Zhe [Konkuk University, Seoul (Korea, Republic of)

    2016-05-15

    Many studies have been conducted recently on an integrated hybrid actuator due to the increasing need for unmanned aircraft and guided weapons. In this study, flow distribution was analyzed for a reed valve which was used for flow regulation to improve the performance of the actuator. By using a Fluid structural interaction (FSI) technique with Computational fluid dynamics (CFD) having a moving mesh, numerical analysis was performed according to the thickness, shape and driving frequency of the reed valve. From the calculated results, the maximum performance of the reed valve was found at the valve thickness of 0.15 mm and the driving frequency of 250 Hz for a no-load state. The optimum thickness and shape for the valve for each driving frequency were also realized.

  10. Transient flow analysis of integrated valve opening process

    Energy Technology Data Exchange (ETDEWEB)

    Sun, Xinming; Qin, Benke; Bo, Hanliang, E-mail: bohl@tsinghua.edu.cn; Xu, Xingxing

    2017-03-15

    Highlights: • The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the integrated valve (IV) is the key control component. • The transient flow experiment induced by IV is conducted and the test results are analyzed to get its working mechanism. • The theoretical model of IV opening process is established and applied to get the changing rule of the transient flow characteristic parameters. - Abstract: The control rod hydraulic driving system (CRHDS) is a new type of built-in control rod drive technology and the IV is the key control component. The working principle of integrated valve (IV) is analyzed and the IV hydraulic experiment is conducted. There is transient flow phenomenon in the valve opening process. The theoretical model of IV opening process is established by the loop system control equations and boundary conditions. The valve opening boundary condition equation is established based on the IV three dimensional flow field analysis results and the dynamic analysis of the valve core movement. The model calculation results are in good agreement with the experimental results. On this basis, the model is used to analyze the transient flow under high temperature condition. The peak pressure head is consistent with the one under room temperature and the pressure fluctuation period is longer than the one under room temperature. Furthermore, the changing rule of pressure transients with the fluid and loop structure parameters is analyzed. The peak pressure increases with the flow rate and the peak pressure decreases with the increase of the valve opening time. The pressure fluctuation period increases with the loop pipe length and the fluctuation amplitude remains largely unchanged under different equilibrium pressure conditions. The research results lay the base for the vibration reduction analysis of the CRHDS.

  11. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  12. Development of a stainless steel check valve for cryogenic applications

    NARCIS (Netherlands)

    Veenstra, T.T.; Venhorst, G.C.F.; Venhorst, G.C.F.; Burger, Johannes Faas; Holland, Herman J.; ter Brake, Hermanus J.M.; Sirbi, A.; Rogalla, Horst

    2007-01-01

    This paper describes the development of a check valve for use in a sorption compressor that will drive a 10 mW 4.5 K Joule–Thomson cryocooler. For the check valve extremely low backflow rates are tolerable at an operating temperature of the valve of 50 K. To fulfill these requirements, the sealing

  13. Control rod drive mechanism

    International Nuclear Information System (INIS)

    Mizuno, Katsuyuki.

    1976-01-01

    Object: To restrict the reduction in performance due to stress corrosion cracks by making use of condensate produced in a turbine steam condenser. Structure: Water produced in a turbine steam condenser is forced into a condensed water desalting unit by low pressure condensate pump. The condensate is purified and then forced by a high pressure condensate pump into a feedwater heater for heating before it is returned to the reactor by a feedwater pump. Part of the condensate issuing from the condensate desalting unit is branched from the remaining portion at a point upstream the pump and is withdrawn into a control rod drive water pump after passing through a motordriven bypass valve, an orifice and a condenser water level control valve, is pressurized in the control rod drive water desalting unit and supplied to a control rod drive water pressure system. The control rod is vertically moved by the valve operation of the water pressure system. Since water of high oxygen concentration does not enter during normal operation, it is possible to prevent the stress cracking of the stainless steel apparatus. (Nakamura, S.)

  14. Investigation of New Servo Drive Concept Utilizing Two Fixed Displacement Units

    DEFF Research Database (Denmark)

    Pedersen, Henrik C.; Schmidt, Lasse; Andersen, Torben Ole

    2014-01-01

    Traditional valve controlled hydraulic drives have an inherent power loss, due to the throttling over the valves, which limits the maximum system efficiency. Pump controlled direct drives do not have this inherent limitation, but are limited when it comes to controlling asymmetric cylinders, why...

  15. Investigation of New Servo Drive Concept Utilizing Two Fixed Displacement Units

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Schmidt, Lasse; Andersen, Torben O.

    2015-01-01

    Traditional valve controlled hydraulic drives have an inherent power loss, due to the throttling over the valves, which limits the maximum system efficiency. Pump controlled direct drives do not have this inherent limitation, but are limited when it comes to controlling asymmetric cylinders, why...

  16. Cam-driven monochromator for QEXAFS

    Energy Technology Data Exchange (ETDEWEB)

    Caliebe, W.A. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); So, I. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Lenhard, A. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States); Siddons, D.P. [National Synchrotron Light Source, Brookhaven National Laboratory, Upton, NY 11973 (United States)

    2006-11-15

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way.

  17. Cam-driven monochromator for QEXAFS

    Science.gov (United States)

    Caliebe, W. A.; So, I.; Lenhard, A.; Siddons, D. P.

    2006-11-01

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way.

  18. Cam-driven monochromator for QEXAFS

    International Nuclear Information System (INIS)

    Caliebe, W.A.; So, I.; Lenhard, A.; Siddons, D.P.

    2006-01-01

    We have developed a cam-drive for quickly tuning the energy of an X-ray monochromator through an X-ray absorption edge for quick extended X-ray absorption spectroscopy (QEXAFS). The data are collected using a 4-channel, 12-bit multiplexed VME analog to digital converter and a VME angle encoder. The VME crate controller runs a real-time operating system. This system is capable of collecting 2 EXAFS-scans in 1 s with an energy stability of better than 1 eV. Additional improvements to increase the speed and the energy stability are under way

  19. Experimental study on coil of direct action solenoid valve with temperature increasing

    International Nuclear Information System (INIS)

    Wang Lu; Liu Qianfeng; Bo Hanliang

    2012-01-01

    Hydraulic control rod drive technology (HCRDT) is a newly invented patent and Institute of Nuclear and New Energy Technology of Tsinghua University owns HCRDT's independent intellectual property rights. The integrated valve which is made up of three direct action solenoid valves is the key part of this technology, so the performance of the solenoid valve directly affects the function of the integrated valve and the HCRDT. Based on the conditions occurring in the operation of the control rod hydraulic drive system, the coil of the direct action solenoid valve with temperature increasing was studied by the experiment and analyzed by ANSYS code. The result shows that the temperature of the coil for the solenoid valve increases with the current increasing firstly. The temperature of the inner wall of the coil is higher than that of the exterior wall. The temperature of the middle coil is higher than that of the edge of the coil. The design of the direct action solenoid valve can be optimized. (authors)

  20. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    International Nuclear Information System (INIS)

    Mahrous, A-F.M.; Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P.

    2009-01-01

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing

  1. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    Energy Technology Data Exchange (ETDEWEB)

    Mahrous, A-F.M. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lecturer at the Department of Mechanical Power Engineering, Faculty of Engineering (Shebin El-Kom), Menoufiya University, Shebin El-Kom (Egypt); Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2009-02-15

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing. (author)

  2. Nanopatterned acellular valve conduits drive the commitment of blood-derived multipotent cells

    Directory of Open Access Journals (Sweden)

    Di Liddo R

    2016-10-01

    Full Text Available Rosa Di Liddo,1,2 Paola Aguiari,3 Silvia Barbon,1,2 Thomas Bertalot,1 Amit Mandoli,1 Alessia Tasso,1 Sandra Schrenk,1 Laura Iop,3 Alessandro Gandaglia,3 Pier Paolo Parnigotto,2 Maria Teresa Conconi,1,2 Gino Gerosa31Department of Pharmaceutical and Pharmacological Sciences, University of Padova, 2Foundation for Biology and Regenerative Medicine, Tissue Engineering and Signaling ONLUS, 3Department of Cardiac, Thoracic and Vascular Sciences, University of Padova, Padova, Italy Abstract: Considerable progress has been made in recent years toward elucidating the correlation among nanoscale topography, mechanical properties, and biological behavior of cardiac valve substitutes. Porcine TriCol scaffolds are promising valve tissue engineering matrices with demonstrated self-repopulation potentiality. In order to define an in vitro model for investigating the influence of extracellular matrix signaling on the growth pattern of colonizing blood-derived cells, we cultured circulating multipotent cells (CMC on acellular aortic (AVL and pulmonary (PVL valve conduits prepared with TriCol method and under no-flow condition. Isolated by our group from Vietnamese pigs before heart valve prosthetic implantation, porcine CMC revealed high proliferative abilities, three-lineage differentiative potential, and distinct hematopoietic/endothelial and mesenchymal properties. Their interaction with valve extracellular matrix nanostructures boosted differential messenger RNA expression pattern and morphologic features on AVL compared to PVL, while promoting on both matrices the commitment to valvular and endothelial cell-like phenotypes. Based on their origin from peripheral blood, porcine CMC are hypothesized in vivo to exert a pivotal role to homeostatically replenish valve cells and contribute to hetero- or allograft colonization. Furthermore, due to their high responsivity to extracellular matrix nanostructure signaling, porcine CMC could be useful for a preliminary

  3. Virtual Design of a Controller for a Hydraulic Cam Phasing System

    Science.gov (United States)

    Schneider, Markus; Ulbrich, Heinz

    2010-09-01

    Hydraulic vane cam phasing systems are nowadays widely used for improving the performance of combustion engines. At stationary operation, these systems should achieve a constant phasing angle, which however is badly disturbed by the alternating torque generated by the valve actuation. As the hydraulic system shows a non-linear characteristic over the full operation range and the inductivity of the hydraulic pipes generates a significant time delay, a full model based control emerges very complex. Therefore a simple feed-forward controller is designed, bridging the time delay of the hydraulic system and improving the system behaviour significantly.

  4. Energy Saving Potential in Knuckle Boom Cranes using a Novel Pump Controlled Cylinder Drive

    Directory of Open Access Journals (Sweden)

    Søren Ketelsen

    2018-04-01

    Full Text Available This paper is considering the application of a novel pump controlled cylinder drive, the so-called Speed-variable Switched Differential Pump (SvSDP, for knuckle boom crane actuation. Especially the control system for the SvSDP drive is considered, and aiming on improving energy efficiency a refinement of the existing control structure is proposed. An energy efficient sizing algorithm for the SvSDP drive is developed, and fundamental differences between the achievable operating range for the SvSDP drive compared to a conventional valve-cylinder drive are discussed. A case study is conducted with knuckle boom crane actuation, and compared to a conventional valve actuation. Simulation results show that the motion tracking performance is on a similar level compared to the valve actuation approach, while the energy consumption is drastically decreased. For the given test trajectory the valve actuation system consumes 0.79 kWh of electrical energy, while the SvSDP drive consume 0.06 kWh, if ideal energy recovery and storage is assumed.

  5. Flowfield Analysis of a Pneumatic Solenoid Valve

    Directory of Open Access Journals (Sweden)

    Sheam-Chyun Lin

    2018-07-01

    Full Text Available Pneumatic solenoid valve has been widely used in the vehicle control systems for meeting the rapid-reaction demand triggered by the dynamic conditions encountered during the driving course of vehicle. For ensuring the safety of human being, the reliable and effective solenoid valve is in great demand to shorten the reaction time and thus becomes the topic of this research. This numerical study chooses a commercial 3/2-way solenoid valve as the reference valve for analysing its performance. At first, CFD software Fluent is adopted to simulate the flow field associated with the valve configuration. Then, the comprehensive flow visualization is implemented to identify the locations of adverse flow patterns. Accordingly, it is found that a high-pressure region exists in the zone between the nozzle exit and the top of iron core. Thereafter, the nozzle diameter and the distance between nozzle and spool are identified as the important design parameters for improving the pressure response characteristics of valve. In conclusion, this work establishes a rigorous and systematic CFD scheme to evaluate the performance of pneumatic solenoid valve.

  6. Special Section: Complementary and Alternative Medicine (CAM): Low Back Pain and CAM

    Science.gov (United States)

    ... Home Current Issue Past Issues Special Section CAM Low Back Pain and CAM Past Issues / Winter 2009 Table of ... benefit from CAM treatment for conditions such as low back pain. Photo courtesy of Glenn Scimonelli "Oh, my aching ...

  7. Hydraulic system for driving control rods

    International Nuclear Information System (INIS)

    Okuzumi, Naoaki.

    1982-01-01

    Purpose: To enable safety reactor shut down upon occurrence of an abnormal excess pressure in a hydraulic control unit. Constitution: The actuation pressure for a pressure switch that generates a scram signal is set lower than the release pressure set to a pressure release valve. Thus, if the pressure of nitrogen gas in a nitrogen container increases such as upon exposure of the hydraulic control unit to a high temperature, the pressure switch is actuated at first to generate the scram signal and a scram valve is opened to supply water at high pressure to control rod drives under the driving force of the nitrogen gas at high pressure to rapidly insert the control element into the reactor and shut down it. If the pressure of the nitrogen gas still increases after the scram, the pressure release valve is opened to release the nitrogen gas at high temperature to the atmosphere. Since the scram is attained before the actuation of the pressure release valve, safety reactor shut down can be attained and the hydraulic control unit can be protected. (Sekiya, K.)

  8. Evaluation of the tightness of contact between 
limbal sclera tunnel and tube following Ahmed 
glaucoma valve implantation.

    Science.gov (United States)

    Holló, Gábor; Naghizadeh, Farzaneh

    2013-01-01

    To investigate whether the tightness of contact between the tube and the limbal sclera tunnel can be evaluated with high-magnification anterior segment optical coherence tomography (OCT) imaging following Ahmed glaucoma valve implantation. Tightness between the tube and the limbal sclera tunnel was investigated with the CAM-L cornea lens adapter of the Optovue Fourier-domain OCT (RTVue-OCT) for 21 uncomplicated Ahmed glaucoma valves implanted in 20 eyes of 19 patients with glaucoma. Nineteen valves were implanted 4 to 124 months earlier (late postoperative cases) and 2 valves 1 day prior to the imaging (early postoperative cases). All valves were introduced into the anterior chamber via a limbal sclera tunnel. The limbal intratunnel part of the tube was successfully imaged in all but 2 cases where an additional full-thickness sclera patch was used. In 14 cases, the contact was tight without tube compression. In 
5 cases, the tube was partially compressed but remained open in the limbal sclera tunnel, and redilated behind the limbus. No case with loose contact or peritubular filtration was seen. The posterior run of the tube was successfully imaged in all 19 cases without a full-thickness sclera patch. High-magnification imaging with the CAM- L anterior segment adapter of the RTVue-OCT allows detailed examination of the limbal insertion area of tubes in both the early and late postoperative periods. Therefore this method may potentially be applied for detection of complications related to tube insertion after glaucoma drainage device surgery.

  9. Development of an ITER prototype disruption mitigation valve

    Energy Technology Data Exchange (ETDEWEB)

    Czymek, G., E-mail: g.czymek@fz-juelich.de [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, D52425 Jülich (Germany); Giesen, B., E-mail: ingenieurbuero.giesen@gmx.de [IBG, Sibertstr. 22, D-52525 Heinsberg (Germany); Charl, A.; Panin, A.; Hiller, A.; Nicolai, D.; Neubauer, O.; Koslowski, H.R.; Sandri, N. [Institute of Energy and Climate Research – Plasma Physics, Forschungszentrum Jülich GmbH, D52425 Jülich (Germany)

    2015-10-15

    Highlights: • An ITER-DMV prototype for 100 bar, D = 80 mm, opening time 3.5 ms, is ready for fabrication. • The vacuum part is sealed against the working gas by stainless steel bellows for 110 bar. • The conical Laval gas outlet allows maximal mass flow rate. • The eddy current drive turn ratio was optimized for low tilting moment. • Polyimide is used for the head sealing, the decelerator and for the bearing of the guide tube. - Abstract: Disruptions in tokamaks seem to be unavoidable. Consequences of disruptions are (i) high heat loads on plasma-facing components, (ii) large forces on the vacuum vessel, and (iii) the generation of runaway electron beams. In ITER, the thermal energy of the plasma needs to be evenly distributed on the first wall in order to prevent melting, forces from vertical displacement events have to be minimized, and the generation of runaway electrons suppressed. Massive gas injection using fast valves is a concept for disruption mitigation which is presently being explored in many tokamaks. Fast disruption mitigation valves based on an electromagnetic eddy current drive have been developed in Jülich since the 1990s and models of various sizes have been built and are in operation in the TEXTOR, MAST, and JET tokamaks. A disruption mitigation valve for ITER is of necessity larger with an estimated injected gas volume of ∼20 kPa m{sup 3}[7] for runaway electron suppression and all materials used have to be resistant to much higher levels of neutron and gamma radiation than in existing tokamaks. During the last 5 years, the concept for an ITER prototype disruption mitigation valve has been developed up to the stage that a fully functional valve could be built and tested. Special emphasis was given to the development and functional testing of some critical items: (i) the injection chamber seal, (ii) the piston seal, (iii) the eddy current drive, and (iv) a braking mechanism to avoid too fast closure of the valve, which could damage

  10. Facultative crassulacean acid metabolism (CAM) plants: powerful tools for unravelling the functional elements of CAM photosynthesis.

    Science.gov (United States)

    Winter, Klaus; Holtum, Joseph A M

    2014-07-01

    Facultative crassulacean acid metabolism (CAM) describes the optional use of CAM photosynthesis, typically under conditions of drought stress, in plants that otherwise employ C3 or C4 photosynthesis. In its cleanest form, the upregulation of CAM is fully reversible upon removal of stress. Reversibility distinguishes facultative CAM from ontogenetically programmed unidirectional C3-to-CAM shifts inherent in constitutive CAM plants. Using mainly measurements of 24h CO2 exchange, defining features of facultative CAM are highlighted in five terrestrial species, Clusia pratensis, Calandrinia polyandra, Mesembryanthemum crystallinum, Portulaca oleracea and Talinum triangulare. For these, we provide detailed chronologies of the shifts between photosynthetic modes and comment on their usefulness as experimental systems. Photosynthetic flexibility is also reviewed in an aquatic CAM plant, Isoetes howellii. Through comparisons of C3 and CAM states in facultative CAM species, many fundamental biochemical principles of the CAM pathway have been uncovered. Facultative CAM species will be of even greater relevance now that new sequencing technologies facilitate the mapping of genomes and tracking of the expression patterns of multiple genes. These technologies and facultative CAM systems, when joined, are expected to contribute in a major way towards our goal of understanding the essence of CAM. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  11. Potential problems will drillstring safety valves

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-06-01

    In the paper titled ``New generation drill string safety valves,`` presented at the IADC Well Control Conference for Europe, Aberdeen, May 22--24, 1996, documented limitations of presently available drillstring safety valves commonly used as kelly valves and stabbing valves were presented, and industry efforts to develop solutions to these problems were described. Authors of the paper are B.A. Tarr and R.A. Sukup (Mobil E and P Technology Center, Dallas), Dr. R. Luy (ITE, Clausthal, Germany), G. Rabby (Hi-Kalibre, Edmonton, Alberta) and J. Mertsch (ITAG, Celle, Germany). In 1995, the Task Group developed a draft of a new spec, and a DSSV testing program was initiated as a joint industry project, with the Gas Research Institute (GRI) as the major sponsor. Two manufacturers, Hi-Kalibre and ITAG, agreed to build new valves for the testing program. Hi-Kalibre, Edmonton, Alberta, supplied an already-commercial twin floating ball valve for November 1995 testing. This product is being used by Tesco in its portable top drive system. ITAG of Germany supplied a radically improved DSSV design, which was tested in December, and was to be retested in May following modifications.

  12. Design of a cam-form tool in precision reuse of a digital paper display

    International Nuclear Information System (INIS)

    Pa, Pai-Shan

    2010-01-01

    A reuse fabrication module that uses micro electroremoving as a precision machining process with a new design of the cam-form tool to remove defective indium-tin-oxide (ITO) thin film from the optical PET surfaces of a digital paper display is presented. A small diameter of the cathode of the cam-form tool corresponds to a higher removal rate for the ITO nanostructure. A small edge radius of the anode and a small gap width between the cathode and the ITO surface takes less time for the same amount of ITO removal. A higher feed rate of the optical PET diaphragm combines with enough electric power to drive fast micro-electroremoving. The high rotational speed of the cam-form tool can improve the effect of dreg discharge and is advantageous to associate with the fast feed rate of the optical PET diaphragm.

  13. Characterization of SynCAM surface trafficking using a SynCAM derived ligand with high homophilic binding affinity

    International Nuclear Information System (INIS)

    Breillat, Christelle; Thoumine, Olivier; Choquet, Daniel

    2007-01-01

    In order to better probe SynCAM function in neurons, we produced a fusion protein between the extracellular domain of SynCAM1 and the constant fragment of human IgG (SynCAM-Fc). Whether in soluble form or immobilized on latex microspheres, the chimera bound specifically to the surface of hippocampal neurons and recruited endogenous SynCAM molecules. SynCAM-Fc was also used in combination with Quantum Dots to follow the mobility of transfected SynCAM receptors at the neuronal surface. Both immobile and highly mobile SynCAM were found. Thus, SynCAM-Fc behaves as a high affinity ligand that can be used to study the function of SynCAM at the neuronal membrane

  14. PreCam

    Energy Technology Data Exchange (ETDEWEB)

    Allam, Sahar S. [Fermilab; Tucker, Douglas L. [Fermilab

    2015-01-01

    The Dark Energy Survey (DES) will be taking the next step in probing the properties of Dark Energy and in understanding the physics of cosmic acceleration. A step towards the photometric calibration of DES is to have a quick, bright survey in the DES footprint (PreCam), using a pre-production set of the Dark Energy Camera (DECam) CCDs and a set of 100 mm×100 mm DES filters. The objective of the PreCam Survey is to create a network of calibrated DES grizY standard stars that will be used for DES nightly calibrations and to improve the DES global relative calibrations. Here, we describe the first year of PreCam observation, results, and photometric calibrations.

  15. Motorized CPM/CAM physiotherapy device with sliding-mode Fuzzy Neural Network control loop.

    Science.gov (United States)

    Ho, Hung-Jung; Chen, Tien-Chi

    2009-11-01

    Continuous passive motion (CPM) and controllable active motion (CAM) physiotherapy devices promote rehabilitation of damaged joints. This paper presents a computerized CPM/CAM system that obviates the need for mechanical resistance devices such as springs. The system is controlled by a computer which performs sliding-mode Fuzzy Neural Network (FNN) calculations online. CAM-type resistance force is generated by the active performance of an electric motor which is controlled so as to oppose the motion of the patient's leg. A force sensor under the patient's foot on the device pedal provides data for feedback in a sliding-mode FNN control loop built around the motor. Via an active impedance control feedback system, the controller drives the motor to behave similarly to a damped spring by generating and controlling the amplitude and direction of the pedal force in relation to the patient's leg. Experiments demonstrate the high sensitivity and speed of the device. The PC-based feedback nature of the control loop means that sophisticated auto-adaptable CPM/CAM custom-designed physiotherapy becomes possible. The computer base also allows extensive data recording, data analysis and network-connected remote patient monitoring.

  16. Adaptive Sliding Mode Control for Hydraulic Drives

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben Ole; Pedersen, Henrik C.

    2013-01-01

    This paper presents a new adaptive sliding mode controller generally applicable for position tracking control of electro-hydraulic valve-cylinder drives (VCD’s). The proposed control scheme requires limited knowledge on system parameters, and employs only piston- and valve spool position feedback...... employing parameter adaption through a recursive algorithm is presented. This is based on a reduced order model approximation of a VCD with unmatched valve flow- and cylinder asymmetries. Bounds on parameters are obtained despite lack of parameter knowledge, and the proposed controller demonstrates improved...

  17. Development of multilayer piezoelectric actuator valve for JT-60

    International Nuclear Information System (INIS)

    Miyo, Yasuhiko; Hiratsuka, Hajime; Masui, Hiroshi; Hosogane, Nobuyuki; Miya, Naoyuki

    2001-11-01

    In order to improve the gas injection valve used for the operation of JT-60, a new type of valve (multilayer piezoelectric actuator valve) was developed. The conventional valve (bimorph piezoelectric valve) has been used for 15 years since the beginning of experimental operation in April, 1985. However, it came to be hard to keep the performance of the valve because of the deterioration of the driving source, i.e. piezoelectric element. Developments of the new valve were carried out based on experiences through experimental operations in JT-60. Requirements for the design are: (1) to be hard structure for making a sheet leak, (2) to allow a repair work at atmosphere side without an air vent of the vacuum vessel, (3) to be more smaller and lighter compared with the conventional one, and (4) to have a high maintenance efficiency by utilizing of the commercial piezoelectric elements and power supplies. The newly developed valve was examined with various tests such as gas flow characteristic test, high magnetic field proof test, high temperature proof test and gas flow rate test for aged deterioration. Results, confirm that the performance of the valve is applicable for JT-60 operations. (author)

  18. Control rod driving hydraulic device

    International Nuclear Information System (INIS)

    Sugano, Hiroshi.

    1993-01-01

    In a control rod driving hydraulic device for an improved BWR type reactor, a bypass pipeline is disposed being branched from a scram pipeline, and a control orifice and a throttle valve are interposed to the bypass pipeline for restricting pressure. Upon occurrence of scram, about 1/2 of water quantity flowing from an accumulator of a hydraulic control unit to the lower surface of a piston of control rod drives by way of a scram pipeline is controlled by the restricting orifice and the throttle valve, by which the water is discharged to a pump suction pipeline or other pipelines by way of the bypass pipeline. With such procedures, a function capable of simultaneously conducting scram for two control rod drives can be attained by one hydraulic control unit. Further, an excessive peak pressure generated by a water hammer phenomenon in the scram pipeline or the control rod drives upon occurrence of scram can be reduced. Deformation and failure due to the excessive peak pressure can be prevented, as well as vibrations and degradation of performance of relevant portions can be prevented. (N.H.)

  19. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  20. ''VaneCAM'' - the third generation of camshaft adjustment systems; ''VaneCAM'' - Nockenwellenversteller der dritten Generation

    Energy Technology Data Exchange (ETDEWEB)

    Knecht, A. [Hydraulik-Ring GmbH, Nuertingen (Germany). Entwicklung Motorentechnik; Stephan, W. [Hydraulik-Ring GmbH, Nuertingen (Germany); Hannibal, W. [Fachhochschule Suedwestfalen, Iserlohn (Germany). Labor fuer Konstruktion und CAE-Anwendungen

    2002-04-01

    Continuously variable camphasers are now well established for modern spark-ignition engines in high-volume production. With the latest generation of camshaft adjustment systems using the vane-type actuator principle, it is possible to move rapidly and reliably through a large adjustment angle. The layout of these adjusting systems is very simple. The production costs are low in comparison to the first generation of camphasers using spur/helical gears to vary the valve timing. The new-generation systems are mechatronic, with the function depending on the coordination and tuning of hydraulic actuation and engine electronics. The term 'VaneCAM' is used for the continuously variable systems of this new generation supplied by Hydraulik-Ring in Nuertingen, Germany. (orig.) [German] Stufenlos wirkende Nockenwellenversteller haben sich an modernen Ottomotoren in den letzten Jahren in der Grossserie etabliert. Mit der neuesten Generation von Nockenwellenverstellern, die nach dem Schwenkmotor-Prinzip aufgebaut sind, lassen sich grosse Verdrehwinkel sehr schnell und betriebssicher verstellen. Der Aufbau dieser Versteller ist einfach, und die Herstellkosten sind gering im Vergleich zur ersten Generation von Verstellern. Bei den Systemen der neuen Generation handelt es sich um mechatronische Systeme, deren Funktion von dem Zusammenspiel und der Abstimmung von hydraulischer Ansteuerung und Motorelektronik abhaengt. Mit dem Begriff 'VaneCAM' werden die stufenlos wirkenden Systeme dieser neuen Generation von Hydraulik-Ring aus Nuertingen bezeichnet. (orig.)

  1. Hydraulic pressure control unit for control rod drive

    International Nuclear Information System (INIS)

    Watabe, Yukio.

    1990-01-01

    The pressure invention concerns a hydraulic pressure control unit for control rod drives in BWR type reactors. The space above a floating piston possessed by an accumulator and the housing of control rod drives are connected by means of a pipeline. The pipeline has a scram valve which is opened upon occurrence of reactor scram. A pump is disposed between the accumulator and the scram valve for communicating a discharge port to apply a high pressure water to the accumulator. According to the present invention, a control unit is disposed between the scram valve and the housing of the control rod drives in the hydraulic pressure control unit for maintaining the cross sectional area of the flow channel of the pipeline to a usual size when the pressure in a pressure vessel is under a rated operation pressure, while limiting the cross sectional area of the flow channel when the pressure is lower than that in the rated operation. Thus, whole insertion of the control rod substantially at a constant speed is enabled irrespective of the level of the pressure in the pressure vessel. (I.S.)

  2. Sliding Control with Chattering Elimination for Hydraulic Drives

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben Ole; Pedersen, Henrik C.

    2012-01-01

    This paper presents the development of a sliding mode control scheme with chattering elimination, generally applicable for position tracking control of electro-hydraulic valve-cylinder drives. The proposed control scheme requires only common data sheet information, no knowledge on load characteri......This paper presents the development of a sliding mode control scheme with chattering elimination, generally applicable for position tracking control of electro-hydraulic valve-cylinder drives. The proposed control scheme requires only common data sheet information, no knowledge on load...... controller is developed for the control derivative based on a reduced order model. Simulation results demonstrate strong robustness when subjected to parameter perturbations and that chattering is eliminated....

  3. Optimisation Methods for Cam Mechanisms

    Directory of Open Access Journals (Sweden)

    Claudia–Mari Popa

    2010-01-01

    Full Text Available In this paper we present the criteria which represent the base of optimizing the cam mechanisms and also we perform the calculations for several types of mechanisms. We study the influence of the constructive parameters in case of the simple machines with rotation cam and follower (flat or curve of translation on the curvature radius and that of the transmission angle. As it follows, we present the optimization calculations of the cam and flat rotation follower mechanisms, as well as the calculations for optimizing the cam mechanisms by circular groove followers’ help. For an easier interpretation of the results, we have visualized the obtained cam in AutoCAD according to the script files generated by a calculation program.

  4. State feedback integral control for a rotary direct drive servo valve using a Lyapunov function approach.

    Science.gov (United States)

    Yu, Jue; Zhuang, Jian; Yu, Dehong

    2015-01-01

    This paper concerns a state feedback integral control using a Lyapunov function approach for a rotary direct drive servo valve (RDDV) while considering parameter uncertainties. Modeling of this RDDV servovalve reveals that its mechanical performance is deeply influenced by friction torques and flow torques; however, these torques are uncertain and mutable due to the nature of fluid flow. To eliminate load resistance and to achieve satisfactory position responses, this paper develops a state feedback control that integrates an integral action and a Lyapunov function. The integral action is introduced to address the nonzero steady-state error; in particular, the Lyapunov function is employed to improve control robustness by adjusting the varying parameters within their value ranges. This new controller also has the advantages of simple structure and ease of implementation. Simulation and experimental results demonstrate that the proposed controller can achieve higher control accuracy and stronger robustness. Copyright © 2014 ISA. Published by Elsevier Ltd. All rights reserved.

  5. Expression, crystallization and preliminary diffraction studies of the Pseudomonas putida cytochrome P450cam operon repressor CamR

    International Nuclear Information System (INIS)

    Maenaka, Katsumi; Fukushi, Kouji; Aramaki, Hironori; Shirakihara, Yasuo

    2005-01-01

    The P. putida cytochrome P450cam operon repressor CamR has been expressed in E. coli and crystallized in space group P2 1 2 1 2. The Pseudomonas putida cam repressor (CamR) is a homodimeric protein that binds to the camO DNA operator to inhibit the transcription of the cytochrome P450cam operon camDCAB. CamR has two functional domains: a regulatory domain and a DNA-binding domain. The binding of the inducer d-camphor to the regulatory domain renders the DNA-binding domain unable to bind camO. Native CamR and its selenomethionyl derivative have been overproduced in Escherichia coli and purified. Native CamR was crystallized under the following conditions: (i) 12–14% PEG 4000, 50 mM Na PIPES, 0.1 M KCl, 1% glycerol pH 7.3 at 288 K with and without camphor and (ii) 1.6 M P i , 50 mM Na PIPES, 2 mM camphor pH 6.7 at 278 K. The selenomethionyl derivative CamR did not crystallize under either of these conditions, but did crystallize using 12.5% PEG MME 550, 25 mM Na PIPES, 2.5 mM MgCl 2 pH 7.3 at 298 K. Preliminary X-ray diffraction studies revealed the space group to be orthorhombic (P2 1 2 1 2), with unit-cell parameters a = 48.0, b = 73.3, c = 105.7 Å. Native and selenomethionyl derivative data sets were collected to 3 Å resolution at SPring-8 and the Photon Factory

  6. Analysis of electromagnetic field of direct action solenoid valve with current changing

    International Nuclear Information System (INIS)

    Liu Qianfeng; Bo Hanliang; Qin Benke

    2009-01-01

    Control rod hydraulic drive mechanism(CRHDM) is a newly invented patent of Institute of Nuclear and New Energy Technology of Tsinghua University. The direct action solenoid valve is the key part of this technology, so the performance of the solenoid valve directly affects the function of the CRHDM. With the current and the air gap changing,the electromagnetic field of the direct action solenoid valve was analyzed using the ANSYS software,which was validated by the experiment. The result shows that the electromagnetic force of the solenoid valve increases with the current increasing or the gap between the two armatures decreasing. Further more, the working current was confirmed. (authors)

  7. Ecophysiology of Crassulacean Acid Metabolism (CAM).

    Science.gov (United States)

    Lüttge, Ulrich

    2004-06-01

    Crassulacean Acid Metabolism (CAM) as an ecophysiological modification of photosynthetic carbon acquisition has been reviewed extensively before. Cell biology, enzymology and the flow of carbon along various pathways and through various cellular compartments have been well documented and discussed. The present attempt at reviewing CAM once again tries to use a different approach, considering a wide range of inputs, receivers and outputs. Input is given by a network of environmental parameters. Six major ones, CO(2), H(2)O, light, temperature, nutrients and salinity, are considered in detail, which allows discussion of the effects of these factors, and combinations thereof, at the individual plant level ('physiological aut-ecology'). Receivers of the environmental cues are the plant types genotypes and phenotypes, the latter including morphotypes and physiotypes. CAM genotypes largely remain 'black boxes', and research endeavours of genomics, producing mutants and following molecular phylogeny, are just beginning. There is no special development of CAM morphotypes except for a strong tendency for leaf or stem succulence with large cells with big vacuoles and often, but not always, special water storage tissues. Various CAM physiotypes with differing degrees of CAM expression are well characterized. Output is the shaping of habitats, ecosystems and communities by CAM. A number of systems are briefly surveyed, namely aquatic systems, deserts, salinas, savannas, restingas, various types of forests, inselbergs and paramós. While quantitative census data for CAM diversity and biomass are largely missing, intuition suggests that the larger CAM domains are those systems which are governed by a network of interacting stress factors requiring versatile responses and not systems where a single stress factor strongly prevails. CAM is noted to be a strategy for variable, flexible and plastic niche occupation rather than lush productivity. 'Physiological syn-ecology' reveals

  8. Complementary and alternative medicine use of women with breast cancer : Self-help CAM attracts other women than guided CAM therapies

    NARCIS (Netherlands)

    Lo-Fo-Wong, Deborah N. N.; Ranchor, Adelita V.; de Haes, Hanneke C. J. M.; Sprangers, Mirjam A. G.; Henselmans, Inge

    2012-01-01

    Objective: Examine stability of use of complementary and alternative medicine (CAM) of breast cancer patients, reasons for CAM use, and sociodemographic, clinical, and psychological predictors of CAM use. Methods: CAM use was assessed after adjuvant therapy and six months later. Following the CAM

  9. Complementary and alternative medicine use of women with breast cancer: Self-help CAM attracts other women than guided CAM therapies

    NARCIS (Netherlands)

    Lo-Fo-Wong, Deborah N. N.; Ranchor, Adelita V.; de Haes, Hanneke C. J. M.; Sprangers, Mirjam A. G.; Henselmans, Inge

    2012-01-01

    Objective: Examine stability of use of complementary and alternative medicine (CAM) of breast cancer patients, reasons for CAM use, and sociodemographic, clinical, and psychological predictors of CAM use. Methods: CAM use was assessed after adjuvant therapy and six months later. Following the CAM

  10. Robust Position Tracking for Electro-Hydraulic Drives Based on Generalized Feedforward Compensation Approach

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben Ole; Pedersen, Henrik C.

    2012-01-01

    This paper presents a robust tracking control concept based on accurate feedforward compensation for hydraulic valve-cylinder drives. The proposed feedforward compensator is obtained utilizing a generalized description of the valve flow that takes into account any asymmetry of valves and...... constant gain type feedforward compensator, when subjected to strong perturbations in supply pressure and coulomb friction....

  11. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  12. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve.

    Science.gov (United States)

    Gutfrind, Christophe; Dufour, Laurent; Liebart, Vincent; Vannier, Jean-Claude; Vidal, Pierre

    2016-05-20

    The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP) Exhaust Gas Recirculation (EGR) valve for use in Internal Combustion Engines (ICEs). The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM) using the FLUX-3D(®) software (CEDRAT, Meylan, France) will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink(®) in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system.

  13. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve

    Science.gov (United States)

    Gutfrind, Christophe; Dufour, Laurent; Liebart, Vincent; Vannier, Jean-Claude; Vidal, Pierre

    2016-01-01

    The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP) Exhaust Gas Recirculation (EGR) valve for use in Internal Combustion Engines (ICEs). The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM) using the FLUX-3D® software (CEDRAT, Meylan, France) will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink® in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system. PMID:27213398

  14. Evaluation of the flow forces on an open centre directional control valve by means of a computational fluid dynamic analysis

    International Nuclear Information System (INIS)

    Amirante, R.; Del Vescovo, G.; Lippolis, A.

    2006-01-01

    The aim of the present paper is the evaluation of the driving forces acting on a 4/3 hydraulic open center directional control valve spool by means of a complete numerical analysis. In a previous paper by the same authors, the valve was inserted in a closed hydraulic circuit and was tested with different pump flow rate values to obtain experimental results about the driving forces. The experimental results are used in this paper to evaluate and validate the numerical analysis of the valve. The obtained numerical results show important differences between an open center valve and a closed center one, the latter being extensively analyzed in the literature. The numerical analysis is performed by using the commercial code 'Fluent', and the numerical results show the complete flow field inside the valve. The aim of this analysis is to evaluate the valve fluid dynamic performance, exploiting computational fluid dynamics (CFD) techniques, in order to give the reliable indications needed to define the valve design criteria and avoid expensive experimental tests

  15. Output Feedback Control of Electro-Hydraulic Cylinder Drives using the Twisting Algorithm

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben Ole; Pedersen, Henrik C.

    2014-01-01

    contributions in literature. This paper considers the twisting algorithm when applied directly for output feedback control, and with the design based on a reduced order model representation of an arbitrary valve driven hydraulic cylinder drive. The consequence of implementing such a controller with the well......This paper discusses the utilization of the so-called twisting algorithm when applied in output feedback position control schemes for electro-hydraulic cylinder drives. The twisting controller was the first second order sliding controller ever introduced, and can structure-wise be considered...... feedback controller may be successfully applied to hydraulic valve driven cylinder drives, with performance being on the level with a conventional surface based first order sliding mode controller....

  16. Should CAM and CAM Training Programs Be Included in the Curriculum of Schools That Provide Health Education?

    Directory of Open Access Journals (Sweden)

    2016-12-01

    Full Text Available Objectives: This study aimed to determine the knowledge levels and attitudes of School of Health and Vocational School of Health students toward complementary and alternative medicine (CAM. Methods: Three hundred thirty-three (333 students studying at the Mehmet Akif Ersoy University School of Health and the Golhisar Vocational School of Health in Burdur, Turkey, were included in the study. Research data were collected by using a survey method based on the expressed opinions of the participants. Results: Of the participants, 69.7% were female and 97% were single (unmarried. Of cigarette users and those with chronic illnesses, 46.8% and 47.8%, respectively, used CAM. Those using CAM were statistically more likely to be female (P < 0.021, to have higher grades (P < 0.007, to be single (P < 0.005, to be vocational school of health graduates (P < 0.008, and to have fathers at work (P < 0.021. While 9.6% of the students thought CAM to be nonsense, 10.8% thought that the methods of CAM should be tried before consulting a doctor. Conclusion: A majority of the students in the study population were found to use complementary and alternative medicine, but that they lacked information about its methods. As a way to address this, CAM should be included in the curriculum of schools that provide health education, and CAM training programs should be given to healthcare professionals to improve their knowledge of CAM. In Turkey, many more studies should be performed to determine nurses’ and doctors’ knowledge of and attitudes about CAM methods so that they can give correct guidance to society and take more active responsibility in improving patient safety.

  17. Electronic drive and acquisition system for mass spectrometry

    Science.gov (United States)

    Schaefer, Rembrandt Thomas (Inventor); Mojarradi, Mohammad (Inventor); Chutjian, Ara (Inventor); Darrach, Murray R. (Inventor); MacAskill, John (Inventor); Tran, Tuan (Inventor); Burke, Gary R. (Inventor); Madzunkov, Stojan M. (Inventor); Blaes, Brent R. (Inventor); Thomas, John L. (Inventor)

    2010-01-01

    The present invention discloses a mixed signal RF drive electronics board that offers small, low power, reliable, and customizable method for driving and generating mass spectra from a mass spectrometer, and for control of other functions such as electron ionizer, ion focusing, single-ion detection, multi-channel data accumulation and, if desired, front-end interfaces such as pumps, valves, heaters, and columns.

  18. CAMS achievements in 1995

    International Nuclear Information System (INIS)

    Berg, Oe.; Fantoni, P.; Iguchi, Y.; Meyer, G.; Soerensen, A.; Dyck, C. van.

    1996-01-01

    CAMS (Computerized Accident Management Support) is a system being developed as a joint research activity at the Halden Reactor Project with additional financing from the Swedish Nuclear Inspectorate (SKI) and the Nordic NKS/RAK-2 project. Three types of users are envisaged: the staff in the control room, the staff in the technical support centre and the staff at a national emergency centre. It is still an experimental system. The Swedish Nuclear Inspectorate kindly accepted to test CAMS at a safety exercise on the 4th of May, 1995. CAMS is designed assuming automatic data transfer from the plant. Missing the data link, a simulator running in the next room was updated now and then with data received by phone. As seen from CAMS, it did not matter if the data came from a fake plant or from a real plant, except that the data were delayed. Overall, it seemed that CAMS can be a very important tool for a national authority. A data link from the plant would increase its usefulness. Several comments on design features were collected and will be used to improve the system. The model needs more inputs to control the main parameters, and a larger repertoire of fault conditions should be put into the model. In the second half of 1995 the work on CAMS has concentrated upon designing new modules for signal validation, tracking simulation and state identification. This will provide better capabilities for on-line monitoring and assessment of the plant state. Further, it has been proposed to introduce Probabilistic Safety Assessment (PSA) to assist in risk monitoring. A first prototype has been made on a personal computer showing the main features of such a PSA module. (au)

  19. The new L4 gasoline engines with VALVEMATIC system

    Energy Technology Data Exchange (ETDEWEB)

    Harada, Jun; Yamada, Tetsu; Watanabe, Kenji [Toyota Motor Corporation, Aichi (Japan)

    2008-07-01

    Reduction of CO{sub 2} emissions is one of the major responsibilities of car manufacturers. It is an especially urgent task to develop new technologies with a simple, compact and widely applicable mechanism which can be used for middle class engines of mass volume production category. Toyota has developed a continuously variable valve timing and lift control system called 'VALVEMATIC'. By implementing this system fuel consumption can be improved by using smaller valve lift during low and middle engine loads (reduction of pumping loss by closing the intake valve earlier). The system consists of a special rocker arm which realizes continuously variable valve timing and lift. It is located between a conventional roller-rocker arm and the camshaft. An electrically actuated motor is used to control the lift and valve opening duration, while a hydraulically controlled variable valve timing mechanism (VVT-i) is also applied on both intake and exhaust cam shafts. The newly developed actuator contains Toyota's original planetary roller screw unit translating rotary movement of the motor into linear actuation. Thanks to the alignment of rocking center and actuator drive direction, a compact design has been achieved. In 2007, VALVEMATIC has been introduced into the Japanese market on a 2.0L engine (3ZR-FAE), which has the largest displacement of the ZR series. The engine employs a cam housing structure with valve train system separated from the cylinder head. The structure realized a high ratio of part commonization with the conventional engine, and an easy mounting of the VALVEMATIC-system by changing only the cam housing assembly. The engine achieved 5-10% fuel consumption improvement and good drivability by using a newly developed cooperative control of VALVEMATIC, VVT-i and the throttle valve. Maximum power also improved by approximately 11kW thanks to the maximized volumetric efficiency using VALVEMATIC. Furthermore, exhaust emissions were improved due to

  20. *Abstracts - 7th IN-CAM Research Symposium, Evaluating CAM Practices: Effectiveness, Integration, Economics & Safety - November 2012.

    Science.gov (United States)

    Boon, Heather; Verhoef, Marja J

    2012-10-23

    Abstract The following are abstracts of oral and poster presentations given at the 7th IN-CAM Research Symposium - Evaluating CAM Practices: Effectiveness, Integration, Economics & Safety, and the 4th HomeoNet Research Forum, a pre-Symposium event. The IN-CAM Research Symposium was held November 2 to 4, 2012 at the Leslie Dan Faculty of Pharmacy, University of Toronto, in Toronto, Ontario, Canada. For more information, please visit: www.incamresearch.ca.

  1. Thyroid Disease and Complementary and Alternative Medicine (CAM)

    Science.gov (United States)

    ... Alternative Medicine in Thyroid Disease Complementary and Alternative Medicine in Thyroid Disease (CAM) WHAT IS COMPLEMENTARY AND ALTERNATIVE MEDICINE (CAM)? Complementary and Alternative Medicine (CAM) is defined ...

  2. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  3. The new Toyota variable valve timing and lift system

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, K.; Fuwa, N.; Yoshihara, Y. [Toyota Motor Corporation (Japan); Hori, K. [Toyota Boshoku Corporation (Japan)

    2007-07-01

    A continuously variable valve timing (duration and phase) and lift system was developed. This system was applied to the valvetrain of a new 2.0L L4 engine (3ZRFAE) for the Japanese market. The system has rocker arms, which allow continuously variable timing and lift, situated between a conventional roller-rocker arm and the camshaft, an electromotor actuator to drive it and a phase mechanism for intake and exhaust camshafts (Dual VVT-i). The rocking center of the rocker arm is stationary, and the axial linear motion of a helical spline changes the initial phase of the rocker arm which varies the timing and lift. The linear motion mechanism uses an original planetary roller screw and is driven by a brushless motor with a built-in electric control unit. Since the rocking center and the linear motion helical spline center coincide, a compact cylinder head design was possible, and the cylinder head is a common design with a conventional engine. Since the ECU controls intake valve duration and timing, a fuel economy gain of maximum 10% (depending on driving condition) is obtained by reducing light to medium load pumping losses. Also intake efficiency was maximized throughout the speed range, resulting in a power gain of 10%. Further, HC emissions were reduced due to increased air speed at low valve lift. (orig.)

  4. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  5. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  6. Design and Optimization of Fast Switching Valves for Large Scale Digital Hydraulic Motors

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck

    The present thesis is on the design, analysis and optimization of fast switching valves for digital hydraulic motors with high power ratings. The need for such high power motors origins in the potential use of hydrostatic transmissions in wind turbine drive trains, as digital hydraulic machines...... have been shown to improve the overall efficiency and efficient operation range compared to traditional hydraulic machines. Digital hydraulic motors uses electronically controlled independent seat valves connected to the pressure chambers, which must be fast acting and exhibit low pressure losses...... to enable efficient operation. These valves are complex components to design, as multiple design aspects are present in these integrated valve units, with conflicting objectives and interdependencies. A preliminary study on a small scale single-cylinder digital hydraulic pump has initially been conducted...

  7. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  8. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  9. New Content Addressable Memory (CAM) Technologies for Big Data and Intelligent Electronics Enabled by Magneto-Electric Ternary CAM

    Science.gov (United States)

    2017-12-11

    AFRL-RY-WP-TR-2017-0198 NEW CONTENT ADDRESSABLE MEMORY (CAM) TECHNOLOGIES FOR BIG DATA AND INTELLIGENT ELECTRONICS ENABLED BY MAGNETO-ELECTRIC...MEMORY (CAM) TECHNOLOGIES FOR BIG DATA AND INTELLIGENT ELECTRONICS ENABLED BY MAGNETO-ELECTRIC TERNARY CAM 5a. CONTRACT NUMBER FA8650-16-1-7655 5b... electronic applications, such as internet of things, big data, wireless sensors, and mobile devices, have begun to focus on the importance of energy

  10. The new BMW four-cylinder four-valve engine. Der neue BMW-Vierzylinder-Vierventilmotor

    Energy Technology Data Exchange (ETDEWEB)

    Bender, K.H.; Ederer, G.; Frerk, J.; Kramer, F.

    1989-09-01

    BMW offers with the 318is a new sporty 3 series model since September 1989. This new BMW is equipped with a new 1.8-l-four-valve engine, which had been developed on the basis of the 1.8-l-two-valve engine. Technical features are two overhead camshafts driven by a duplex chain drive, bucket tappet control with integrated hydraulic valve clearance compensation and a distributorless direct fire ignition system. In addition to the increase of the maximum output to 100 kW the advantages of the four-valve-technique have been used to achieve a remarkable low end troque characteristic. The maximum bmep of 1.2 kJ/dm{sup 3} (corresponds to172 Nm) at an engine speed of 4600 rpm is a notable level for a catalitic converter model. Extraordinary development work in the lay out of mixture preparation, combustion process and exhaust gas treatment in general resulted in more favourable emissions and fuel consumption figures compared with two valve engines. (orig.).

  11. Immunomodulation of Autoimmune Arthritis by Herbal CAM

    Directory of Open Access Journals (Sweden)

    Shivaprasad H. Venkatesha

    2011-01-01

    Full Text Available Rheumatoid arthritis (RA is a debilitating autoimmune disease of global prevalence. The disease is characterized by synovial inflammation leading to cartilage and bone damage. Most of the conventional drugs used for the treatment of RA have severe adverse reactions and are quite expensive. Over the years, increasing proportion of patients with RA and other immune disorders are resorting to complementary and alternative medicine (CAM for their health needs. Natural plant products comprise one of the most popular CAM for inflammatory and immune disorders. These herbal CAM belong to diverse traditional systems of medicine, including traditional Chinese medicine, Kampo, and Ayurvedic medicine. In this paper, we have outlined the major immunological pathways involved in the induction and regulation of autoimmune arthritis and described various herbal CAM that can effectively modulate these immune pathways. Most of the information about the mechanisms of action of herbal products in the experimental models of RA is relevant to arthritis patients as well. The study of immunological pathways coupled with the emerging application of genomics and proteomics in CAM research is likely to provide novel insights into the mechanisms of action of different CAM modalities.

  12. Complementary and alternative medicine (CAM providers’ views of chronic low back pain patients’ expectations of CAM therapies: a qualitative study

    Directory of Open Access Journals (Sweden)

    Schafer Lisa M

    2012-11-01

    Full Text Available Abstract Background Some researchers think that patients with higher expectations for CAM therapies experience better outcomes and that enthusiastic providers can enhance treatment outcomes. This is in contrast to evidence suggesting conventional medical providers often reorient patient expectations to better match what providers believe to be realistic. However, there is a paucity of research on CAM providers’ views of their patients’ expectations regarding CAM therapy and the role of these expectations in patient outcomes. Methods To better understand how CAM providers view and respond to their patients’ expectations of a particular therapy, we conducted 32 semi-structured, qualitative interviews with acupuncturists, chiropractors, massage therapists and yoga instructors identified through convenience sampling. Interviews were recorded, transcribed and analyzed thematically using Atlas ti version 6.1. Results CAM providers reported that they attempt to ensure that their patients’ expectations are realistic. Providers indicated they manage their patients’ expectations in a number of domains— roles and responsibilities of providers and patients, treatment outcomes, timeframe for improvement, and treatment experience. Providers reported that patients’ expectations change over time and that they need to continually manage these expectations to enhance patient engagement and satisfaction with treatment. Conclusions Providers of four types of CAM therapies viewed patients’ expectations as an important component of their experiences with CAM therapy and indicated that they try to align patient expectations with reality. These findings suggest that CAM providers are similar in this respect to conventional medical providers.

  13. Complementary and alternative medicine (CAM) providers' views of chronic low back pain patients' expectations of CAM therapies: a qualitative study.

    Science.gov (United States)

    Schafer, Lisa M; Hsu, Clarissa; Eaves, Emery Rose; Ritenbaugh, Cheryl; Turner, Judith; Cherkin, Daniel C; Sims, Colette; Sherman, Karen J

    2012-11-27

    Some researchers think that patients with higher expectations for CAM therapies experience better outcomes and that enthusiastic providers can enhance treatment outcomes. This is in contrast to evidence suggesting conventional medical providers often reorient patient expectations to better match what providers believe to be realistic. However, there is a paucity of research on CAM providers' views of their patients' expectations regarding CAM therapy and the role of these expectations in patient outcomes. To better understand how CAM providers view and respond to their patients' expectations of a particular therapy, we conducted 32 semi-structured, qualitative interviews with acupuncturists, chiropractors, massage therapists and yoga instructors identified through convenience sampling. Interviews were recorded, transcribed and analyzed thematically using Atlas ti version 6.1. CAM providers reported that they attempt to ensure that their patients' expectations are realistic. Providers indicated they manage their patients' expectations in a number of domains- roles and responsibilities of providers and patients, treatment outcomes, timeframe for improvement, and treatment experience. Providers reported that patients' expectations change over time and that they need to continually manage these expectations to enhance patient engagement and satisfaction with treatment. Providers of four types of CAM therapies viewed patients' expectations as an important component of their experiences with CAM therapy and indicated that they try to align patient expectations with reality. These findings suggest that CAM providers are similar in this respect to conventional medical providers.

  14. Knowledge and training needs among Danish nurses about CAM

    DEFF Research Database (Denmark)

    Lunde, Anita

    2010-01-01

    to explore nurses’ knowledge about CAM and their needs for training. Methods: Similar to international investigations a Danish “CAM-knowledge” questionnaire was developed that included multiple choice, yes/no and 5 points scale answers. Validity was established through initial pilot testing. Contacts...... to a randomized sample of 2500 nurses were established through the Danish Nurses Foundation. The questionnaires were mailed by post with the possibility of anonymous return. The data material was analyzed using non-parametic methods. Results: The response rate was 67 % and 1458 completed questionnaires were...... of CAM also tend to have a theoretical background of CAM. Around 75 % of the nurses agree or partly agree that it is important for nurses to receive education about CAM and that nurses have knowledge about CAM that enables them to advise patients. Training needs concerning CAM were indicated by 52...

  15. Engine Cycle Analysis of Air Breathing Microwave Rocket with Reed Valves

    International Nuclear Information System (INIS)

    Fukunari, Masafumi; Komatsu, Reiji; Yamaguchi, Toshikazu; Komurasaki, Kimiya; Arakawa, Yoshihiro; Katsurayama, Hiroshi

    2011-01-01

    The Microwave Rocket is a candidate for a low cost launcher system. Pulsed plasma generated by a high power millimeter wave beam drives a blast wave, and a vehicle acquires impulsive thrust by exhausting the blast wave. The thrust generation process of the Microwave Rocket is similar to a pulse detonation engine. In order to enhance the performance of its air refreshment, the air-breathing mechanism using reed valves is under development. Ambient air is taken to the thruster through reed valves. Reed valves are closed while the inside pressure is high enough. After the time when the shock wave exhausts at the open end, an expansion wave is driven and propagates to the thrust-wall. The reed valve is opened by the negative gauge pressure induced by the expansion wave and its reflection wave. In these processes, the pressure oscillation is important parameter. In this paper, the pressure oscillation in the thruster was calculated by CFD combined with the flux through from reed valves, which is estimated analytically. As a result, the air-breathing performance is evaluated using Partial Filling Rate (PFR), the ratio of thruster length to diameter L/D, and ratio of opening area of reed valves to superficial area α. An engine cycle and predicted thrust was explained.

  16. CFD analysis on the dynamic flow characteristics of the pilot-control globe valve

    International Nuclear Information System (INIS)

    Qian, Jin-yuan; Wei, Lin; Jin, Zhi-jiang; Wang, Jian-kai; Zhang, Han; Lu, An-le

    2014-01-01

    Highlights: • PCGV utilizes pressure difference to control the action of the valve core. • Three different opening processes with the same spring stiffness are analyzed. • Valve core’s displacements with different spring stiffness are analyzed. • The best design point of spring stiffness and inlet pressure is obtained. • The selection formula for the design of PCGV is generalized. - Abstract: The pilot-control globe valve (PCGV) is a new kind valve with simple structures and low driving energy consumption. It can utilize the pressure difference before and after the valve to control the action of the valve core. However, systematic theoretical research and numerical analysis are deficient at present. In this paper, the mathematical model of PCGV is established and Computational Fluid Dynamics (CFD) method is employed to numerically simulate its dynamic characteristics. Through the analysis of the internal flow field distribution, its working principle is verified. Then three different opening processes with the same spring stiffness are analyzed under different static inlet pressures, and the best design point is obtained by studying the characteristic curves of the valve core’s displacement. The relationship of static inlet pressure and the valve core’s displacement is summarized and the selection formula for the valve design is generalized which can reduce the various design work for further optimization and engineering applications of PCGV

  17. Baking Powder Actuated Centrifugo-Pneumatic Valving for Automation of Multi-Step Bioassays

    Directory of Open Access Journals (Sweden)

    David J. Kinahan

    2016-10-01

    Full Text Available We report a new flow control method for centrifugal microfluidic systems; CO2 is released from on-board stored baking powder upon contact with an ancillary liquid. The elevated pressure generated drives the sample into a dead-end pneumatic chamber sealed by a dissolvable film (DF. This liquid incursion wets and dissolves the DF, thus opening the valve. The activation pressure of the DF valve can be tuned by the geometry of the channel upstream of the DF membrane. Through pneumatic coupling with properly dimensioned disc architecture, we established serial cascading of valves, even at a constant spin rate. Similarly, we demonstrate sequential actuation of valves by dividing the disc into a number of distinct pneumatic chambers (separated by DF membranes. Opening these DFs, typically through arrival of a liquid to that location on a disc, permits pressurization of these chambers. This barrier-based scheme provides robust and strictly ordered valve actuation, which is demonstrated by the automation of a multi-step/multi-reagent DNA-based hybridization assay.

  18. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  19. Treatment Preferences for CAM in Children with Chronic Pain

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2007-01-01

    Full Text Available CAM therapies have become increasingly popular in pediatric populations. Yet, little is known about children's preferences for CAM. This study examined treatment preferences in chronic pediatric pain patients offered a choice of CAM therapies for their pain. Participants were 129 children (94 girls (mean age = 14.5 years ± 2.4; range = 8–18 years presenting at a multidisciplinary, tertiary clinic specializing in pediatric chronic pain. Bivariate and multivariate analyses were used to examine the relationships between CAM treatment preferences and patient's sociodemographic and clinical characteristics, as well as their self-reported level of functioning. Over 60% of patients elected to try at least one CAM approach for pain. The most popular CAM therapies were biofeedback, yoga and hypnosis; the least popular were art therapy and energy healing, with craniosacral, acupuncture and massage being intermediate. Patients with a diagnosis of fibromyalgia (80% were the most likely to try CAM versus those with other pain diagnoses. In multivariate analyses, pain duration emerged as a significant predictor of CAM preferences. For mind-based approaches (i.e. hypnosis, biofeedback and art therapy, pain duration and limitations in family activities were both significant predictors. When given a choice of CAM therapies, this sample of children with chronic pain, irrespective of pain diagnosis, preferred non-invasive approaches that enhanced relaxation and increased somatic control. Longer duration of pain and greater impairment in functioning, particularly during family activities increased the likelihood that such patients agreed to engage in CAM treatments, especially those that were categorized as mind-based modalities.

  20. Treatment Preferences for CAM in children with chronic pain.

    Science.gov (United States)

    Tsao, Jennie C I; Meldrum, Marcia; Kim, Su C; Jacob, Margaret C; Zeltzer, Lonnie K

    2007-09-01

    CAM therapies have become increasingly popular in pediatric populations. Yet, little is known about children's preferences for CAM. This study examined treatment preferences in chronic pediatric pain patients offered a choice of CAM therapies for their pain. Participants were 129 children (94 girls) (mean age = 14.5 years +/- 2.4; range = 8-18 years) presenting at a multidisciplinary, tertiary clinic specializing in pediatric chronic pain. Bivariate and multivariate analyses were used to examine the relationships between CAM treatment preferences and patient's sociodemographic and clinical characteristics, as well as their self-reported level of functioning. Over 60% of patients elected to try at least one CAM approach for pain. The most popular CAM therapies were biofeedback, yoga and hypnosis; the least popular were art therapy and energy healing, with craniosacral, acupuncture and massage being intermediate. Patients with a diagnosis of fibromyalgia (80%) were the most likely to try CAM versus those with other pain diagnoses. In multivariate analyses, pain duration emerged as a significant predictor of CAM preferences. For mind-based approaches (i.e. hypnosis, biofeedback and art therapy), pain duration and limitations in family activities were both significant predictors. When given a choice of CAM therapies, this sample of children with chronic pain, irrespective of pain diagnosis, preferred non-invasive approaches that enhanced relaxation and increased somatic control. Longer duration of pain and greater impairment in functioning, particularly during family activities increased the likelihood that such patients agreed to engage in CAM treatments, especially those that were categorized as mind-based modalities.

  1. CAMS: OLAPing Multidimensional Data Streams Efficiently

    Science.gov (United States)

    Cuzzocrea, Alfredo

    In the context of data stream research, taming the multidimensionality of real-life data streams in order to efficiently support OLAP analysis/mining tasks is a critical challenge. Inspired by this fundamental motivation, in this paper we introduce CAMS (C ube-based A cquisition model for M ultidimensional S treams), a model for efficiently OLAPing multidimensional data streams. CAMS combines a set of data stream processing methodologies, namely (i) the OLAP dimension flattening process, which allows us to obtain dimensionality reduction of multidimensional data streams, and (ii) the OLAP stream aggregation scheme, which aggregates data stream readings according to an OLAP-hierarchy-based membership approach. We complete our analytical contribution by means of experimental assessment and analysis of both the efficiency and the scalability of OLAPing capabilities of CAMS on synthetic multidimensional data streams. Both analytical and experimental results clearly connote CAMS as an enabling component for next-generation Data Stream Management Systems.

  2. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  3. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  4. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  5. Chiropractic and CAM utilization: a descriptive review.

    Science.gov (United States)

    Lawrence, Dana J; Meeker, William C

    2007-01-22

    To conduct a descriptive review of the scientific literature examining use rates of modalities and procedures used by CAM clinicians to manage chronic LBP and other conditions A literature of PubMed and MANTIS was performed using the key terms Chiropractic; Low Back Pain; Utilization Rate; Use Rate; Complementary and Alternative Medicine; and Health Services in various combinations. A total of 137 papers were selected, based upon including information about chiropractic utilization, CAM utilization and low back pain and other conditions. Information was extracted from each paper addressing use of chiropractic and CAM, and is summarized in tabular form. Thematic analysis of the paper topics indicated that there were 5 functional areas covered by the literature: back pain papers, general chiropractic papers, insurance-related papers, general CAM-related papers; and worker's compensation papers. Studies looking at chiropractic utilization demonstrate that the rates vary, but generally fall into a range from around 6% to 12% of the population, most of whom seek chiropractic care for low back pain and not for organic disease or visceral dysfunction. CAM is itself used by people suffering from a variety of conditions, though it is often used not as a primary intervention, but rather as an additional form of care. CAM and chiropractic often offer lower costs for comparable results compared to conventional medicine.

  6. CAD/CAM produces dentures with improved fit.

    Science.gov (United States)

    Steinmassl, Otto; Dumfahrt, Herbert; Grunert, Ingrid; Steinmassl, Patricia-Anca

    2018-02-22

    Resin polymerisation shrinkage reduces the congruence of the denture base with denture-bearing tissues and thereby decreases the retention of conventionally fabricated dentures. CAD/CAM denture manufacturing is a subtractive process, and polymerisation shrinkage is not an issue anymore. Therefore, CAD/CAM dentures are assumed to show a higher denture base congruence than conventionally fabricated dentures. It has been the aim of this study to test this hypothesis. CAD/CAM dentures provided by four different manufacturers (AvaDent, Merz Dental, Whole You, Wieland/Ivoclar) were generated from ten different master casts. Ten conventional dentures (pack and press, long-term heat polymerisation) made from the same master casts served as control group. The master casts and all denture bases were scanned and matched digitally. The absolute incongruences were measured using a 2-mm mesh. Conventionally fabricated dentures showed a mean deviation of 0.105 mm, SD = 0.019 from the master cast. All CAD/CAM dentures showed lower mean incongruences. From all CAD/CAM dentures, AvaDent Digital Dentures showed the highest congruence with the master cast surface with a mean deviation of 0.058 mm, SD = 0.005. Wieland Digital Dentures showed a mean deviation of 0.068 mm, SD = 0.005, Whole You Nexteeth prostheses showed a mean deviation of 0.074 mm, SD = 0.011 and Baltic Denture System prostheses showed a mean deviation of 0.086 mm, SD = 0.012. CAD/CAM produces dentures with better fit than conventional dentures. The present study explains the clinically observed enhanced retention and lower traumatic ulcer-frequency in CAD/CAM dentures.

  7. Innovative Design of Cam-Controlled Planetary Gear Trains

    Directory of Open Access Journals (Sweden)

    Wen-Hsiang Hsieh

    2011-10-01

    Full Text Available The objective of this paper is to perform the innovation design for the new structures of cam-controlled planetary gear trains (CCPGTs, based on the creative mechanism design methodology. Firstly, the design requirements and design constraints are summarized according to the kinematics characteristics of existing CCPGTs. Then, the (4, 5 and (5, 7 graphs are generated by the theory of number synthesis. After that, the atlas of feasible specialized graphs is obtained. Finally, the atlas of new designs is obtained through the particularization process. In addition, an illustrated example is given, and the feasibility of the design is verified by computer simulation using ADAMS software. The result indicates that new design can produce a more wide range of non-uniform motion than the existing design. Therefore, they are better alternatives for driving a variable speed input mechanism.

  8. Availability Analysis of the Ventilation Stack CAM Interlock System

    International Nuclear Information System (INIS)

    YOUNG, J.

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability. Further, requiring an alarm to actuate upon CAM failure is not necessary to maintain the availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability. However, if CAM failures were only detected by the 92-day functional tests required in the Authorization Basis (AB), CAM availability would be much less than that credited in the safety analysis. Therefore it is recommended that the current surveillance practice of daily simple system checks, 30-day source checks and 92-day functional tests be continued in order to maintain CAM availability

  9. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  10. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2014-09-01

    Full Text Available Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under light loads and wearing of the variable-displacement pump. To overcome these shortcomings, this article designs a closed hydraulic control system in which an AC servo motor drives a quantitative pump that controls a spiral swinging hydraulic cylinder, and analyzes and calculates the structure and parameters of a spiral swinging hydraulic cylinder. The hydraulic system adjusts the servo motor’s speed according to the requirements of the control system, and the motor power matches the power provided to components, thus eliminating the throttling loss of hydraulic circuits. The system is compact, produces a large output force, provides stable transmission, has a quick response, and is suitable as a hydraulic control system of a large butterfly valve.

  11. Laia de Camões — O épico

    Directory of Open Access Journals (Sweden)

    Lygia Alvares Correa

    1951-06-01

    Full Text Available CIDADE ('liernatii. Laia de Camões — O épico, Revista da Faculdade  de Letras. Tomo XVI. 2.°' série. ns. I e 2. Universidade de Lisboa  1950. (Primeiro Parágrafo do Artigo Este segundo volume que a respeito de Camões escreve o Prof. Cidade surge 14 anos após, "Luiz de Camões".

  12. Chiropractic and CAM Utilization: A Descriptive Review

    Directory of Open Access Journals (Sweden)

    Meeker William C

    2007-01-01

    Full Text Available Abstract Objective To conduct a descriptive review of the scientific literature examining use rates of modalities and procedures used by CAM clinicians to manage chronic LBP and other conditions Data Sources A literature of PubMed and MANTIS was performed using the key terms Chiropractic; Low Back Pain; Utilization Rate; Use Rate; Complementary and Alternative Medicine; and Health Services in various combinations. Data Selection A total of 137 papers were selected, based upon including information about chiropractic utilization, CAM utilization and low back pain and other conditions. Data Synthesis Information was extracted from each paper addressing use of chiropractic and CAM, and is summarized in tabular form. Results Thematic analysis of the paper topics indicated that there were 5 functional areas covered by the literature: back pain papers, general chiropractic papers, insurance-related papers, general CAM-related papers; and worker's compensation papers. Conclusion Studies looking at chiropractic utilization demonstrate that the rates vary, but generally fall into a range from around 6% to 12% of the population, most of whom seek chiropractic care for low back pain and not for organic disease or visceral dysfunction. CAM is itself used by people suffering from a variety of conditions, though it is often used not as a primary intervention, but rather as an additional form of care. CAM and chiropractic often offer lower costs for comparable results compared to conventional medicine.

  13. Genomic analyses of the CAM plant pineapple.

    Science.gov (United States)

    Zhang, Jisen; Liu, Juan; Ming, Ray

    2014-07-01

    The innovation of crassulacean acid metabolism (CAM) photosynthesis in arid and/or low CO2 conditions is a remarkable case of adaptation in flowering plants. As the most important crop that utilizes CAM photosynthesis, the genetic and genomic resources of pineapple have been developed over many years. Genetic diversity studies using various types of DNA markers led to the reclassification of the two genera Ananas and Pseudananas and nine species into one genus Ananas and two species, A. comosus and A. macrodontes with five botanical varieties in A. comosus. Five genetic maps have been constructed using F1 or F2 populations, and high-density genetic maps generated by genotype sequencing are essential resources for sequencing and assembling the pineapple genome and for marker-assisted selection. There are abundant expression sequence tag resources but limited genomic sequences in pineapple. Genes involved in the CAM pathway has been analysed in several CAM plants but only a few of them are from pineapple. A reference genome of pineapple is being generated and will accelerate genetic and genomic research in this major CAM crop. This reference genome of pineapple provides the foundation for studying the origin and regulatory mechanism of CAM photosynthesis, and the opportunity to evaluate the classification of Ananas species and botanical cultivars. © The Author 2014. Published by Oxford University Press on behalf of the Society for Experimental Biology. All rights reserved. For permissions, please email: journals.permissions@oup.com.

  14. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  15. Experimental research and numerical simulation on flow resistance of integrated valve

    International Nuclear Information System (INIS)

    Cai Wei; Bo Hanliang; Qin Benke

    2008-01-01

    The flow resistance of the integrated valve is one of the key parameters for the design of the control rod hydraulic drive system (CRHDS). Experimental research on the improved new integrated valve was performed, and the key data such as pressure difference, volume flow, resistance coefficient and flow coefficient of each flow channel were obtained. With the computational fluid dynamics software CFX, numerical simulation was executed to analyze the effect of Re on the flow resistance. On the basis of experimental and numerical results, fitting empirical formulas of resistance coefficient were obtained, which provide experimental and theoretical foundations for CRHDS's optimized design and theoretical analysis. (authors)

  16. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  17. A Novel Radiation Hardened CAM

    CERN Document Server

    Shojaii, Seyed Ruhollah; The ATLAS collaboration

    2018-01-01

    This poster describes an innovative Content Addressable Memory cell with radiation hardened (RH-CAM) architecture. The RH-CAM is designed in a commercial 28 nm CMOS technology. The circuit has been simulated in worst-case conditions, and the effects due to single particles are analyzed injecting a fault current into a circuit node. The proposed architecture can perform on-time pattern recognition tasks in harsh environments, such as very front-end electronics in hadron colliders and in space applications.

  18. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  19. design analysis of cam-follower system for beat up motion

    African Journals Online (AJOL)

    User

    A cam swing roller-follower mechanism is designed for the beat-up motion of a horizontal narrow loom. The system consists of a radial plate-cam driven by a camshaft keyed to the plate cam. A slay bar which act as the beater is attached to the radial swing roller-follower and assembled on the plate cam. A continuous ...

  20. Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms

    CERN Document Server

    Williams, J J

    2013-01-01

    Modern design methods of Automotive Cam Design require the computation of a range of parameters. This book provides a logical sequence of steps for the derivation of the relevant equations from first principles, for the more widely used cam mechanisms. Although originally derived for use in high performance engines, this work is equally applicable to the design of mass produced automotive and other internal combustion engines.   Introduction to Analytical Methods for Internal Combustion Engine Cam Mechanisms provides the equations necessary for the design of cam lift curves with an associated smooth acceleration curve. The equations are derived for the kinematics and kinetics of all the mechanisms considered, together with those for cam curvature and oil entrainment velocity. This permits the cam shape, all loads, and contact stresses to be evaluated, and the relevant tribology to be assessed. The effects of asymmetry on the manufacture of cams for finger follower and offset translating curved followers is ...

  1. Control rod driving hydraulic pressure device

    International Nuclear Information System (INIS)

    Ishida, Kazuo.

    1990-01-01

    Discharged water after actuating control rod drives in a BWR type reactor is once discharged to a discharging header, then returned to a master control unit and, subsequently, discharged to a reactor by way of a cooling water header. The radioactive level in the discharging header and the master control unit is increased by the reactor water to increase the operator's exposure. In view of the above, a riser is disposed for connecting a hydraulic pressure control unit incorporating a directional control valve and the cooling water head. When a certain control rod is inserted, the pressurized driving water is supplied through a hydraulic pressure control unit to the control rod drives. The discharged water from the control rod drives is entered by way of the hydraulic pressure control unit into the cooling water header and then returned to the reactor by way of other hydraulic pressure control unit and the control rod drives. Thus, the reactor water is no more recycled to the master control unit to reduce the radioactive exposure. (N.H.)

  2. Finding the Evidence in CAM: a Student's Perspective

    Directory of Open Access Journals (Sweden)

    Jeffrey Ghassemi

    2005-01-01

    Full Text Available This commentary offers a future health care provider's perspective on the role of complementary and alternative medicine (CAM in Western (namely, in US medical education and practice. As a student of both public health and medicine in the United States, Jeffrey Ghassemi is interested in CAM's contribution to improving medical practice and teaching. The commentary highlights the ambiguous definitions of CAM to Westerners despite the rising popularity of and expenditures for alternative modalities of care. It then argues for collaboration between alternative and established medical communities to ascertain the scientific merits of CAM. It concludes by calling for a new medical paradigm that embraces the philosophies of both communities to advance education and patient care.

  3. Use of Complementary and Alternative Medicine (CAM) as Part of the Oncological Treatment: Survey about Patients' Attitude towards CAM in a University-Based Oncology Center in Germany.

    Science.gov (United States)

    Kessel, Kerstin A; Lettner, Sabrina; Kessel, Carmen; Bier, Henning; Biedermann, Tilo; Friess, Helmut; Herrschbach, Peter; Gschwend, Jürgen E; Meyer, Bernhard; Peschel, Christian; Schmid, Roland; Schwaiger, Markus; Wolff, Klaus-Dietrich; Combs, Stephanie E

    2016-01-01

    To understand if and which patients would be open-minded to Complementary and Alternative Medicine (CAM) use parallel to their oncological treatment. Moreover, we sought to determine which methods are most accepted and which are the primary motivators to use CAM. We developed and anonymously conducted a questionnaire for patients in the oncology center (TU Munich). Questions focus on different CAM methods, previous experiences, and willingness to apply or use CAM when offered in a university-based setting. A total of 171 of 376 patients (37.4% women, 62.0% men, 0.6% unknown) participated. This corresponds to a return rate of 45%. Median age was 64 years (17-87 years). Of all participants, 15.2% used CAM during their oncological therapy; 32.7% have used it in the past. The majority (81.9%) was not using CAM during therapy; 55.5% have not used CAM in the past respectively. The analysis revealed a significant correlation between education and CAM use during therapy (r = 0.18; p = 0.02), and CAM use in the past (r = 0.17; p = 0.04). Of all patients using CAM during therapy, favored methods were food supplements (42.3%), vitamins/minerals (42.3%), massage (34.6%). Motivations are especially the reduction of side effect and stress, the positive effect of certain CAM-treatments on the immune system and tumor therapy. Results showed no difference between women and men. Most patients not having had any experience with CAM complain about the deficiency of information by their treating oncologist (31.4%) as well as missing treatment possibilities (54.3%). Since many patients believe in study results demonstrating the efficacy of CAM, it stresses our task to develop innovative study protocols to investigate the outcomes of certain CAM on symptom reduction or other endpoints. Thus, prospective trials and innovative evidence-based treatment concepts to include CAM into high-end oncology is what patients demand and what a modern oncology center should offer.

  4. Use of Complementary and Alternative Medicine (CAM as Part of the Oncological Treatment: Survey about Patients' Attitude towards CAM in a University-Based Oncology Center in Germany.

    Directory of Open Access Journals (Sweden)

    Kerstin A Kessel

    Full Text Available To understand if and which patients would be open-minded to Complementary and Alternative Medicine (CAM use parallel to their oncological treatment. Moreover, we sought to determine which methods are most accepted and which are the primary motivators to use CAM.We developed and anonymously conducted a questionnaire for patients in the oncology center (TU Munich. Questions focus on different CAM methods, previous experiences, and willingness to apply or use CAM when offered in a university-based setting.A total of 171 of 376 patients (37.4% women, 62.0% men, 0.6% unknown participated. This corresponds to a return rate of 45%. Median age was 64 years (17-87 years. Of all participants, 15.2% used CAM during their oncological therapy; 32.7% have used it in the past. The majority (81.9% was not using CAM during therapy; 55.5% have not used CAM in the past respectively. The analysis revealed a significant correlation between education and CAM use during therapy (r = 0.18; p = 0.02, and CAM use in the past (r = 0.17; p = 0.04. Of all patients using CAM during therapy, favored methods were food supplements (42.3%, vitamins/minerals (42.3%, massage (34.6%. Motivations are especially the reduction of side effect and stress, the positive effect of certain CAM-treatments on the immune system and tumor therapy. Results showed no difference between women and men. Most patients not having had any experience with CAM complain about the deficiency of information by their treating oncologist (31.4% as well as missing treatment possibilities (54.3%.Since many patients believe in study results demonstrating the efficacy of CAM, it stresses our task to develop innovative study protocols to investigate the outcomes of certain CAM on symptom reduction or other endpoints. Thus, prospective trials and innovative evidence-based treatment concepts to include CAM into high-end oncology is what patients demand and what a modern oncology center should offer.

  5. VALVE TURBO-ALTERNATOR AS ADDITIONAL HYBRID CAR DEVICE FOR THE HIGH-VOLTAGE BATTERY CHARGE

    Directory of Open Access Journals (Sweden)

    S. Kolesnikov

    2009-01-01

    Full Text Available The description of the hybrid car, its drive components and method of the solution of the problem with moving period of the car on electric pulling by means of valve turbo-alternator is given in this article.

  6. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  7. Evaluation and compensation of steady gas flow force on the high-pressure electro-pneumatic servo valve direct-driven by voice coil motor

    International Nuclear Information System (INIS)

    Li, Baoren; Gao, Longlong; Yang, Gang

    2013-01-01

    Highlights: ► A novel energy saving high-pressure electro-pneumatic servo valve is presented. ► An evaluated method for steady gas flow forces on pneumatic valves is proposed. ► Gas jet angles at the orifices for the valve are larger than 69° commonly used. ► The steady gas flow force is strongly nonlinear with valve opening. ► The steady gas flow force is compensated and the aim at energy saving is realized. - Abstract: A novel voice coil motor (VCM) direct drive single stage high-pressure pneumatic servo valve is designed, and then the steady gas flow force acting on the spool of the servo valve is investigated by numerical simulation and experimental methods in this paper. At present, many studies about flow force are concentrated mainly on hydraulic valves, but rarely on pneumatic valves. However, the velocity of gas is up to sonic when high-pressure gas flows through the servo valve orifice. And therefore, the steady gas flow force, generated by high pressure and high speed gas flow, cannot be neglected and is an important disturbance for the VCM direct-drive single stage high-pressure pneumatic servo valve. Consequently, the numerical simulation with computational fluid dynamics (CFD) is adopted to analyze the flow filed, jet angles, and steady gas flow forces for the servo valve with different valve openings and inlet pressures. The experimental study is performed to evaluate and confirm the numerical analysis. Then the compensated approach is proposed to reduce the steady gas flow force for the servo valve, changing the angle of non-metering port designed in the valve sleeve to the spool axis. The results demonstrate that the presented numerical analysis method is validated, the gas jet angle for the servo valve orifice is more than 69° and varies with different spool openings, and the steady gas flow force is nonlinear with valve opening and linear with inlet pressure when the outlet boundary is atmospheric pressure. Moreover, the steady gas

  8. An open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and industrial CAM software.

    Science.gov (United States)

    Lu, Li; Liu, Shusheng; Shi, Shenggen; Yang, Jianzhong

    2011-10-01

    China-made 5-axis simultaneous contouring CNC machine tool and domestically developed industrial computer-aided manufacture (CAM) technology were used for full crown fabrication and measurement of crown accuracy, with an attempt to establish an open CAM system for dental processing and to promote the introduction of domestic dental computer-aided design (CAD)/CAM system. Commercially available scanning equipment was used to make a basic digital tooth model after preparation of crown, and CAD software that comes with the scanning device was employed to design the crown by using domestic industrial CAM software to process the crown data in order to generate a solid model for machining purpose, and then China-made 5-axis simultaneous contouring CNC machine tool was used to complete machining of the whole crown and the internal accuracy of the crown internal was measured by using 3D-MicroCT. The results showed that China-made 5-axis simultaneous contouring CNC machine tool in combination with domestic industrial CAM technology can be used for crown making and the crown was well positioned in die. The internal accuracy was successfully measured by using 3D-MicroCT. It is concluded that an open CAM system for dentistry on the basis of China-made 5-axis simultaneous contouring CNC machine tool and domestic industrial CAM software has been established, and development of the system will promote the introduction of domestically-produced dental CAD/CAM system.

  9. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  10. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  11. The pineapple genome and the evolution of CAM photosynthesis.

    Science.gov (United States)

    Ming, Ray; VanBuren, Robert; Wai, Ching Man; Tang, Haibao; Schatz, Michael C; Bowers, John E; Lyons, Eric; Wang, Ming-Li; Chen, Jung; Biggers, Eric; Zhang, Jisen; Huang, Lixian; Zhang, Lingmao; Miao, Wenjing; Zhang, Jian; Ye, Zhangyao; Miao, Chenyong; Lin, Zhicong; Wang, Hao; Zhou, Hongye; Yim, Won C; Priest, Henry D; Zheng, Chunfang; Woodhouse, Margaret; Edger, Patrick P; Guyot, Romain; Guo, Hao-Bo; Guo, Hong; Zheng, Guangyong; Singh, Ratnesh; Sharma, Anupma; Min, Xiangjia; Zheng, Yun; Lee, Hayan; Gurtowski, James; Sedlazeck, Fritz J; Harkess, Alex; McKain, Michael R; Liao, Zhenyang; Fang, Jingping; Liu, Juan; Zhang, Xiaodan; Zhang, Qing; Hu, Weichang; Qin, Yuan; Wang, Kai; Chen, Li-Yu; Shirley, Neil; Lin, Yann-Rong; Liu, Li-Yu; Hernandez, Alvaro G; Wright, Chris L; Bulone, Vincent; Tuskan, Gerald A; Heath, Katy; Zee, Francis; Moore, Paul H; Sunkar, Ramanjulu; Leebens-Mack, James H; Mockler, Todd; Bennetzen, Jeffrey L; Freeling, Michael; Sankoff, David; Paterson, Andrew H; Zhu, Xinguang; Yang, Xiaohan; Smith, J Andrew C; Cushman, John C; Paull, Robert E; Yu, Qingyi

    2015-12-01

    Pineapple (Ananas comosus (L.) Merr.) is the most economically valuable crop possessing crassulacean acid metabolism (CAM), a photosynthetic carbon assimilation pathway with high water-use efficiency, and the second most important tropical fruit. We sequenced the genomes of pineapple varieties F153 and MD2 and a wild pineapple relative, Ananas bracteatus accession CB5. The pineapple genome has one fewer ancient whole-genome duplication event than sequenced grass genomes and a conserved karyotype with seven chromosomes from before the ρ duplication event. The pineapple lineage has transitioned from C3 photosynthesis to CAM, with CAM-related genes exhibiting a diel expression pattern in photosynthetic tissues. CAM pathway genes were enriched with cis-regulatory elements associated with the regulation of circadian clock genes, providing the first cis-regulatory link between CAM and circadian clock regulation. Pineapple CAM photosynthesis evolved by the reconfiguration of pathways in C3 plants, through the regulatory neofunctionalization of preexisting genes and not through the acquisition of neofunctionalized genes via whole-genome or tandem gene duplication.

  12. Dynamic simulation of a beta-type Stirling engine with cam-drive mechanism via the combination of the thermodynamic and dynamic models

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Chin-Hsiang; Yu, Ying-Ju [Department of Aeronautics and Astronautics, National Cheng Kung University, No. 1, Ta-Shieh Road, Tainan, Taiwan (China)

    2011-02-15

    Dynamic simulation of a beta-type Stirling engine with cam-drive mechanism used in concentrating solar power system has been performed. A dynamic model of the mechanism is developed and then incorporated with the thermodynamic model so as to predict the transient behavior of the engine in the hot-start period. In this study, the engine is started from an initial rotational speed. The torques exerted by the flywheel of the engine at any time instant can be calculated by the dynamic model as long as the gas pressures in the chambers, the mass inertia, the friction force, and the external load have been evaluated. The instantaneous rotation speed of the engine is then determined by integration of the equation of rotational motion with respect to time, which in return affects the instantaneous variations in pressure and other thermodynamic properties of the gas inside the chambers. Therefore, the transient variations in gas properties inside the engine chambers and the dynamic behavior of the engine mechanism should be handled simultaneously via the coupling of the thermodynamic and dynamic models. An extensive parametric study of the effects of different operating and geometrical parameters has been performed, and results regarding the effects of mass moment of inertia of the flywheel, initial rotational speed, initial charged pressure, heat source temperature, phase angle, gap size, displacer length, and piston stroke on the engine transient behavior are investigated. (author)

  13. Abnormal placental development and early embryonic lethality in EpCAM-null mice.

    Directory of Open Access Journals (Sweden)

    Keisuke Nagao

    Full Text Available BACKGROUND: EpCAM (CD326 is encoded by the tacstd1 gene and expressed by a variety of normal and malignant epithelial cells and some leukocytes. Results of previous in vitro experiments suggested that EpCAM is an intercellular adhesion molecule. EpCAM has been extensively studied as a potential tumor marker and immunotherapy target, and more recent studies suggest that EpCAM expression may be characteristic of cancer stem cells. METHODOLOGY/PRINCIPAL FINDINGS: To gain insights into EpCAM function in vivo, we generated EpCAM -/- mice utilizing an embryonic stem cell line with a tacstd1 allele that had been disrupted. Gene trapping resulted in a protein comprised of the N-terminus of EpCAM encoded by 2 exons of the tacstd1 gene fused in frame to betageo. EpCAM +/- mice were viable and fertile and exhibited no obvious abnormalities. Examination of EpCAM +/- embryos revealed that betageo was expressed in several epithelial structures including developing ears (otocysts, eyes, branchial arches, gut, apical ectodermal ridges, lungs, pancreas, hair follicles and others. All EpCAM -/- mice died in utero by E12.5, and were small, developmentally delayed, and displayed prominent placental abnormalities. In developing placentas, EpCAM was expressed throughout the labyrinthine layer and by spongiotrophoblasts as well. Placentas of EpCAM -/- embryos were compact, with thin labyrinthine layers lacking prominent vascularity. Parietal trophoblast giant cells were also dramatically reduced in EpCAM -/- placentas. CONCLUSION: EpCAM was required for differentiation or survival of parietal trophoblast giant cells, normal development of the placental labyrinth and establishment of a competent maternal-fetal circulation. The findings in EpCAM-reporter mice suggest involvement of this molecule in development of vital organs including the gut, kidneys, pancreas, lungs, eyes, and limbs.

  14. Abnormal placental development and early embryonic lethality in EpCAM-null mice.

    Science.gov (United States)

    Nagao, Keisuke; Zhu, Jianjian; Heneghan, Mallorie B; Hanson, Jeffrey C; Morasso, Maria I; Tessarollo, Lino; Mackem, Susan; Udey, Mark C

    2009-12-31

    EpCAM (CD326) is encoded by the tacstd1 gene and expressed by a variety of normal and malignant epithelial cells and some leukocytes. Results of previous in vitro experiments suggested that EpCAM is an intercellular adhesion molecule. EpCAM has been extensively studied as a potential tumor marker and immunotherapy target, and more recent studies suggest that EpCAM expression may be characteristic of cancer stem cells. To gain insights into EpCAM function in vivo, we generated EpCAM -/- mice utilizing an embryonic stem cell line with a tacstd1 allele that had been disrupted. Gene trapping resulted in a protein comprised of the N-terminus of EpCAM encoded by 2 exons of the tacstd1 gene fused in frame to betageo. EpCAM +/- mice were viable and fertile and exhibited no obvious abnormalities. Examination of EpCAM +/- embryos revealed that betageo was expressed in several epithelial structures including developing ears (otocysts), eyes, branchial arches, gut, apical ectodermal ridges, lungs, pancreas, hair follicles and others. All EpCAM -/- mice died in utero by E12.5, and were small, developmentally delayed, and displayed prominent placental abnormalities. In developing placentas, EpCAM was expressed throughout the labyrinthine layer and by spongiotrophoblasts as well. Placentas of EpCAM -/- embryos were compact, with thin labyrinthine layers lacking prominent vascularity. Parietal trophoblast giant cells were also dramatically reduced in EpCAM -/- placentas. EpCAM was required for differentiation or survival of parietal trophoblast giant cells, normal development of the placental labyrinth and establishment of a competent maternal-fetal circulation. The findings in EpCAM-reporter mice suggest involvement of this molecule in development of vital organs including the gut, kidneys, pancreas, lungs, eyes, and limbs.

  15. CamOn: A Real-Time Autonomous Camera Control System

    DEFF Research Database (Denmark)

    Burelli, Paolo; Jhala, Arnav Harish

    2009-01-01

    This demonstration presents CamOn, an autonomous cam- era control system for real-time 3D games. CamOn employs multiple Artificial Potential Fields (APFs), a robot motion planning technique, to control both the location and orienta- tion of the camera. Scene geometry from the 3D environment...... contributes to the potential field that is used to determine po- sition and movement of the camera. Composition constraints for the camera are modelled as potential fields for controlling the view target of the camera. CamOn combines the compositional benefits of constraint- based camera systems, and improves...

  16. Knowledge and training needs among Danish nurses about CAM

    DEFF Research Database (Denmark)

    Lunde, Anita

    2010-01-01

    Background: The increased use of CAM among the Danish population is well documented as are patient’s requests to discuss CAM with a healthcare professional. It is suggested that among different groups of healthcare professionals nurses are the most “open minded” about CAM. This makes it important...... to explore nurses’ knowledge about CAM and their needs for training. Methods: Similar to international investigations a Danish “CAM-knowledge” questionnaire was developed that included multiple choice, yes/no and 5 points scale answers. Validity was established through initial pilot testing. Contacts...... to a randomized sample of 2500 nurses were established through the Danish Nurses Foundation. The questionnaires were mailed by post with the possibility of anonymous return. The data material was analyzed using non-parametic methods. Results: The response rate was 67 % and 1458 completed questionnaires were...

  17. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  18. Inducement of Design Parameters for Reliability Improvement of Servo Actuator for Hydraulic Valve Operation

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Baek Ju; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2014-05-15

    The precision hydraulic valve is widely used in various industrial field like aircraft, automobile, and general machinery. Servo actuator is the most important device for driving the precise hydraulic valve. The reliable operation of servo actuator effects on the overall hydraulic system. The performance of servo actuator relies on frequency response and step response according to arbitrary input signal. In this paper, we performed the analysis for the components of servo actuator to satisfy the reliable operation and response characteristics through the reliability analysis, and also induced the design parameters to realize the reliable operation and fast response characteristics of servo actuator for hydraulic valve operation through the empirical knowledge of experts and electromagnetic theories. We suggested the design equations to determine the values of design parameters of servo actuator as like bobbin size, length of yoke and plunger and turn number of coil, and verified the achieved design values through FEM analysis and performance tests using some prototypes of servo actuators adapted in hydraulic valve.

  19. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  20. Test plan for FY-91 alpha CAM evaluation

    International Nuclear Information System (INIS)

    Winberg, M.R.

    1991-03-01

    This report describes the test plan for evaluating the Merlin Gerin, Inc., Edgar alpha continuous air monitor (CAM) and associated analysis system to be conducted by Idaho National Engineering Laboratory (INEL) for the Department of Energy. INEL has evaluated other commercial alpha CAM systems to detect transuranic contaminants during waste handling and retrieval operations. This test plan outlines experimental methods, sampling methods, sampling and analysis techniques, and equipment needed and safety and quality requirements to test the commercial CAM. 8 refs., 3 figs

  1. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  2. CAM Stochastic Volatility Model for Option Pricing

    Directory of Open Access Journals (Sweden)

    Wanwan Huang

    2016-01-01

    Full Text Available The coupled additive and multiplicative (CAM noises model is a stochastic volatility model for derivative pricing. Unlike the other stochastic volatility models in the literature, the CAM model uses two Brownian motions, one multiplicative and one additive, to model the volatility process. We provide empirical evidence that suggests a nontrivial relationship between the kurtosis and skewness of asset prices and that the CAM model is able to capture this relationship, whereas the traditional stochastic volatility models cannot. We introduce a control variate method and Monte Carlo estimators for some of the sensitivities (Greeks of the model. We also derive an approximation for the characteristic function of the model.

  3. Resin-composite blocks for dental CAD/CAM applications.

    Science.gov (United States)

    Ruse, N D; Sadoun, M J

    2014-12-01

    Advances in digital impression technology and manufacturing processes have led to a dramatic paradigm shift in dentistry and to the widespread use of computer-aided design/computer-aided manufacturing (CAD/CAM) in the fabrication of indirect dental restorations. Research and development in materials suitable for CAD/CAM applications are currently the most active field in dental materials. Two classes of materials are used in the production of CAD/CAM restorations: glass-ceramics/ceramics and resin composites. While glass-ceramics/ceramics have overall superior mechanical and esthetic properties, resin-composite materials may offer significant advantages related to their machinability and intra-oral reparability. This review summarizes recent developments in resin-composite materials for CAD/CAM applications, focusing on both commercial and experimental materials. © International & American Associations for Dental Research.

  4. Electromagnetically powered electrolytic pump and thermo-responsive valve for drug delivery

    KAUST Repository

    Yi, Ying; Zaher, Amir; Yassine, Omar; Buttner, Ulrich; Kosel, Jü rgen; Foulds, Ian G.

    2015-01-01

    A novel drug delivery device is presented, implementing an electrolytic pump and a thermo-responsive valve. The device is remotely operated by an AC electromagnetic field (40.5∼58.5 mT, 450 kHz) that provides the power for the pump and the valve. It is suitable for long-term therapy applications, which use a solid drug in reservoir (SDR) approach and avoids unwanted drug diffusion. When the electromagnetic field is on, the electrolytic pump drives the drug towards the valve. The valve is made of a magnetic composite consisting of a smart hydrogel: Poly (N-Isopropylacrylamide) (PNIPAm) and iron powder. The heat generated in the iron powder via magnetic losses causes the PNIPAm to shrink, allowing the drug to flow past it. When the electromagnetic field is off, the PNIPAm swells, sealing the outlet. In the meantime, the bubbles generated by electrolysis recombine into water, causing a pressure reduction in the pumping chamber. This draws fresh fluid from outside the pump into the drug reservoir before the valve is fully sealed. The recombination can be accelerated by a platinum (Pt) coated catalytic reformer, allowing more fluid to flow back to the drug reservoir and dissolve the drug. By repeatedly turning on and off the magnetic field, the drug solution can be delivered cyclically. © 2015 IEEE.

  5. Electromagnetically powered electrolytic pump and thermo-responsive valve for drug delivery

    KAUST Repository

    Yi, Ying

    2015-04-01

    A novel drug delivery device is presented, implementing an electrolytic pump and a thermo-responsive valve. The device is remotely operated by an AC electromagnetic field (40.5∼58.5 mT, 450 kHz) that provides the power for the pump and the valve. It is suitable for long-term therapy applications, which use a solid drug in reservoir (SDR) approach and avoids unwanted drug diffusion. When the electromagnetic field is on, the electrolytic pump drives the drug towards the valve. The valve is made of a magnetic composite consisting of a smart hydrogel: Poly (N-Isopropylacrylamide) (PNIPAm) and iron powder. The heat generated in the iron powder via magnetic losses causes the PNIPAm to shrink, allowing the drug to flow past it. When the electromagnetic field is off, the PNIPAm swells, sealing the outlet. In the meantime, the bubbles generated by electrolysis recombine into water, causing a pressure reduction in the pumping chamber. This draws fresh fluid from outside the pump into the drug reservoir before the valve is fully sealed. The recombination can be accelerated by a platinum (Pt) coated catalytic reformer, allowing more fluid to flow back to the drug reservoir and dissolve the drug. By repeatedly turning on and off the magnetic field, the drug solution can be delivered cyclically. © 2015 IEEE.

  6. Guidelines for Properly Adjustning Pressure Feedback in Systems with Over-Centre Valves

    DEFF Research Database (Denmark)

    Pedersen, Henrik Clemmensen; Andersen, Torben O.; Hansen, Michael R.

    2016-01-01

    this problem is to use an over centre valve with a sufficiently low pilot ratio and/or include various damping orifices in the system. Both of these solutions are energy consuming and may decrease the control performance. An alternative approach is to use (electronic) pressure feedback — also referred...... to as active damping — to stabilise the system and damp pressure pulsations. This is not a new method, but the effect and adjustment of the filters is often misunderstood leading to incorrectly adjusted filters and degraded system performance. The focus of the current paper is therefore to explain and derive...... a set of guidelines for how to properly adjust a standard pressure feedback in system with an over centre valve when also considering model uncertainties, un-modelled dynamics and parameter variations. The paper takes its basis in a standard cylinder drive with an inertia load, over centre valve...

  7. The use of economic evaluation in CAM: an introductory framework.

    Science.gov (United States)

    Ford, Emily; Solomon, Daniela; Adams, Jon; Graves, Nicholas

    2010-11-11

    For CAM to feature prominently in health care decision-making there is a need to expand the evidence-base and to further incorporate economic evaluation into research priorities.In a world of scarce health care resources and an emphasis on efficiency and clinical efficacy, CAM, as indeed do all other treatments, requires rigorous evaluation to be considered in budget decision-making. Economic evaluation provides the tools to measure the costs and health consequences of CAM interventions and thereby inform decision making. This article offers CAM researchers an introductory framework for understanding, undertaking and disseminating economic evaluation. The types of economic evaluation available for the study of CAM are discussed, and decision modelling is introduced as a method for economic evaluation with much potential for use in CAM. Two types of decision models are introduced, decision trees and Markov models, along with a worked example of how each method is used to examine costs and health consequences. This is followed by a discussion of how this information is used by decision makers. Undoubtedly, economic evaluation methods form an important part of health care decision making. Without formal training it can seem a daunting task to consider economic evaluation, however, multidisciplinary teams provide an opportunity for health economists, CAM practitioners and other interested researchers, to work together to further develop the economic evaluation of CAM.

  8. The use of economic evaluation in CAM: an introductory framework

    Science.gov (United States)

    2010-01-01

    Background For CAM to feature prominently in health care decision-making there is a need to expand the evidence-base and to further incorporate economic evaluation into research priorities. In a world of scarce health care resources and an emphasis on efficiency and clinical efficacy, CAM, as indeed do all other treatments, requires rigorous evaluation to be considered in budget decision-making. Methods Economic evaluation provides the tools to measure the costs and health consequences of CAM interventions and thereby inform decision making. This article offers CAM researchers an introductory framework for understanding, undertaking and disseminating economic evaluation. The types of economic evaluation available for the study of CAM are discussed, and decision modelling is introduced as a method for economic evaluation with much potential for use in CAM. Two types of decision models are introduced, decision trees and Markov models, along with a worked example of how each method is used to examine costs and health consequences. This is followed by a discussion of how this information is used by decision makers. Conclusions Undoubtedly, economic evaluation methods form an important part of health care decision making. Without formal training it can seem a daunting task to consider economic evaluation, however, multidisciplinary teams provide an opportunity for health economists, CAM practitioners and other interested researchers, to work together to further develop the economic evaluation of CAM. PMID:21067622

  9. The use of economic evaluation in CAM: an introductory framework

    Directory of Open Access Journals (Sweden)

    Adams Jon

    2010-11-01

    Full Text Available Abstract Background For CAM to feature prominently in health care decision-making there is a need to expand the evidence-base and to further incorporate economic evaluation into research priorities. In a world of scarce health care resources and an emphasis on efficiency and clinical efficacy, CAM, as indeed do all other treatments, requires rigorous evaluation to be considered in budget decision-making. Methods Economic evaluation provides the tools to measure the costs and health consequences of CAM interventions and thereby inform decision making. This article offers CAM researchers an introductory framework for understanding, undertaking and disseminating economic evaluation. The types of economic evaluation available for the study of CAM are discussed, and decision modelling is introduced as a method for economic evaluation with much potential for use in CAM. Two types of decision models are introduced, decision trees and Markov models, along with a worked example of how each method is used to examine costs and health consequences. This is followed by a discussion of how this information is used by decision makers. Conclusions Undoubtedly, economic evaluation methods form an important part of health care decision making. Without formal training it can seem a daunting task to consider economic evaluation, however, multidisciplinary teams provide an opportunity for health economists, CAM practitioners and other interested researchers, to work together to further develop the economic evaluation of CAM.

  10. Aquatic CAM photosynthesis: a brief history of its discovery

    Science.gov (United States)

    Keeley, Jon E.

    2014-01-01

    Aquatic CAM (Crassulacean Acid Metabolism) photosynthesis was discovered while investigating an unrelated biochemical pathway concerned with anaerobic metabolism. George Bowes was a significant contributor to this project early in its infancy. Not only did he provide me with some valuable perspectives on peer review rejections, but by working with his gas exchange system I was able to take our initial observations of diel fluctuations in malic acid to the next level, showing this aquatic plant exhibited dark CO2 uptake. CAM is universal in all aquatic species of the worldwide Lycophyta genus Isoetes and non-existent in terrestrial Isoetes. Outside of this genus aquatic CAM has a limited occurrence in three other families, including the Crassulaceae. This discovery led to fascinating adventures in the highlands of the Peruvian Andes in search of Stylites, a terrestrial relative of Isoetes. Stylites is a plant that is hermetically sealed from the atmosphere and obtains all of its carbon from terrestrial sources and recycles carbon through CAM. Considering the Mesozoic origin of Isoetes in shallow pools, coupled with the fact that aquatic Isoetes universally possess CAM, suggests the earliest evolution of CAM photosynthesis was most likely not in terrestrial plants.

  11. QUANTIFICATION OF ANGIOGENESIS IN THE CHICKEN CHORIOALLANTOIC MEMBRANE (CAM

    Directory of Open Access Journals (Sweden)

    Silvia Blacher

    2011-05-01

    Full Text Available The chick chorioallantoic membrane (CAM provides a suitable in vivo model to study angiogenesis and evaluate several pro- and anti-angiogenic factors and compounds. In the present work, new developments in image analysis are used to quantify CAM angiogenic response from optical microscopic observations, covering all vascular components, from the large supplying and feeding vessels down to the capillary plexus. To validate our methodology angiogenesis is quantified during two phases of CAM development (day 7 and 13 and after treatment with an antiangiogenic modulator of the angiogenesis. Our morphometric analysis emphasizes that an accurate quantification of the CAM vasculature needs to be performed at various scales.

  12. Valve assembly

    International Nuclear Information System (INIS)

    Sandling, M.

    1981-01-01

    An improved valve assembly, used for controlling the flow of radioactive slurry, is described. Radioactive contamination of the air during removal or replacement of the valve is prevented by sucking air from the atmosphere through a portion of the structure above the valve housing. (U.K.)

  13. Mitral Valve Stenosis

    Science.gov (United States)

    ... the left ventricle from flowing backward. A defective heart valve fails to either open or close fully. Risk factors Mitral valve stenosis is less common today than it once was because the most common cause, ... other heart valve problems, mitral valve stenosis can strain your ...

  14. Structural valve deterioration in a starr-edwards mitral caged-disk valve prosthesis.

    Science.gov (United States)

    Aoyagi, Shigeaki; Tayama, Kei-Ichiro; Okazaki, Teiji; Shintani, Yusuke; Kono, Michitaka; Wada, Kumiko; Kosuga, Ken-Ichi; Mori, Ryusuke; Tanaka, Hiroyuki

    2013-01-01

    The durability of the Starr-Edwards (SE) mitral caged-disk valve, model 6520, is not clearly known, and structural valve deterioration in the SE disk valve is very rare. Replacement of the SE mitral disk valve was performed in 7 patients 23-40 years after implantation. Macroscopic examination of the removed disk valves showed no structural abnormalities in 3 patients, in whom the disk valves were removed at valves excised >36 years after implantation in 4 patients. Disk fracture, a longitudinal split in the disk along its circumference at the site of incorporation of the titanium ring, was detected in the valves removed 36 and 40 years after implantation, respectively, and many cracks were also observed on the outflow aspect of the disk removed 40 years after implantation. Disk fracture and localized disk wear were found in the SE mitral disk valves implanted >36 years previously. The present results suggest that SE mitral caged-disk valves implanted >20 years previously should be carefully followed up, and that those implanted >30 years previously should be electively replaced with modern prosthetic valves

  15. Aortic valve replacement and the stentless Freedom SOLO valve

    NARCIS (Netherlands)

    Wollersheim, L.W.L.M.

    2016-01-01

    Aortic valve stenosis has become the most prevalent valvular heart disease in Europe and North America, and is generally caused by age-related calcification of the aortic valve. For most patients, severe symptomatic aortic stenosis needs effective mechanical relief in the form of valve replacement

  16. Different CAD/CAM-processing routes for zirconia restorations: influence on fitting accuracy.

    Science.gov (United States)

    Kohorst, Philipp; Junghanns, Janet; Dittmer, Marc P; Borchers, Lothar; Stiesch, Meike

    2011-08-01

    The aim of the present in vitro study was to evaluate the influence of different processing routes on the fitting accuracy of four-unit zirconia fixed dental prostheses (FDPs) fabricated by computer-aided design/computer-aided manufacturing (CAD/CAM). Three groups of zirconia frameworks with ten specimens each were fabricated. Frameworks of one group (CerconCAM) were produced by means of a laboratory CAM-only system. The other frameworks were made with different CAD/CAM systems; on the one hand by in-laboratory production (CerconCAD/CAM) and on the other hand by centralized production in a milling center (Compartis) after forwarding geometrical data. Frameworks were then veneered with the recommended ceramics, and marginal accuracy was determined using a replica technique. Horizontal marginal discrepancy, vertical marginal discrepancy, absolute marginal discrepancy, and marginal gap were evaluated. Statistical analyses were performed by one-way analysis of variance (ANOVA), with the level of significance chosen at 0.05. Mean horizontal discrepancies ranged between 22 μm (CerconCAM) and 58 μm (Compartis), vertical discrepancies ranged between 63 μm (CerconCAD/CAM) and 162 μm (CerconCAM), and absolute marginal discrepancies ranged between 94 μm (CerconCAD/CAM) and 181 μm (CerconCAM). The marginal gap varied between 72 μm (CerconCAD/CAM) and 112 μm (CerconCAM, Compartis). Statistical analysis revealed that, with all measurements, the marginal accuracy of the zirconia FDPs was significantly influenced by the processing route used (p manufacture of four-unit FDPs.

  17. Microfluidic sieve valves

    Science.gov (United States)

    Quake, Stephen R; Marcus, Joshua S; Hansen, Carl L

    2015-01-13

    Sieve valves for use in microfluidic device are provided. The valves are useful for impeding the flow of particles, such as chromatography beads or cells, in a microfluidic channel while allowing liquid solution to pass through the valve. The valves find particular use in making microfluidic chromatography modules.

  18. Low Power DEAP Actuator Drive for Heating Valves

    DEFF Research Database (Denmark)

    Huang, Lina

    predict the behaviour and efficiency in both charging and discharging mode. The system level energy consumption is relatively low when the burst mode control scheme is applied. If 2.5 Ah batteries are employed, the high voltage driving system with bidirectional converter can run for around 2.1 years....... efficiency analysis has been carried out to achieve efficiency calculation model. Moreover, two system level control schemes are proposed to achieve the corresponding temperature control. The functionality and energy consumption of the high voltage driver have been verified through the test in the practical...

  19. Quantitative assessment of an aortic and pulmonary valve function according to valve fenestration

    International Nuclear Information System (INIS)

    Mirkhani, S.H.; Golestani, M.G.; Hosini, M.; Kazemian, A.

    1999-01-01

    There are some reasons for malfunction of aortic and pulmonary valve like fibrosis, calcification, and atheroma. Although, in some papers fenestration were known as a pathologic sign, but it is not generally accepted, while this matter is important in choosing suitable Homograft Heart Valve. In this paper fenestrations and its size, numbers and situation effect was studied. We collected 98 hearts, the donors died because of accident, we excluded valves with atheroma, calcification, fibrosis and unequal cusps, 91 aortic and 93 pulmonary valves were given further consideration. We classified valves according to situation, number and size of fenestration. Each valve was tested with 104 cm of non-nal saline column pressure which is equal to 76 mm Hg. Valve efficacy was detected by fluid flow assay. With study of 184 valves, 95 had no fenestration, 64 had less than 2 fenestration and 25 had more than 2 fenestration. Valve efficacy in condition of less than 2 fenestration was more than others (p <0.01). Malfunction effects of fenestration increased in larger valve and it will be decreased if their situation would be marginal (free margin of cusp). In the comparison of aortic and pulmonary valve we saw that malfunction effect of fenestration in pulmonary valve was more than aortic valve. Our experience in Immam Khomeini Homograft Valve Bank has shown that a great deal of valves is fenestrated. It seems that fenestration must be considered as a quality criterion in homograft valve preparation, especially in pulmonary and large aortic valves; but complementary studies is necessary

  20. Sequential transcatheter aortic valve implantation due to valve dislodgement - a Portico valve implanted over a CoreValve bioprosthesis.

    Science.gov (United States)

    Campante Teles, Rui; Costa, Cátia; Almeida, Manuel; Brito, João; Sondergaard, Lars; Neves, José P; Abecasis, João; M Gabriel, Henrique

    2017-03-01

    Transcatheter aortic valve implantation (TAVI) has become an important treatment in high surgical risk patients with severe aortic stenosis (AS), whose complications need to be managed promptly. The authors report the case of an 86-year-old woman presenting with severe symptomatic AS, rejected for surgery due to advanced age and comorbidities. The patient underwent a first TAVI, with implantation of a Medtronic CoreValve ® , which became dislodged and migrated to the ascending aorta. Due to the previous balloon valvuloplasty, the patient's AS became moderate, and her symptoms improved. After several months, she required another intervention, performed with a St. Jude Portico ® repositionable self-expanding transcatheter aortic valve. There was a good clinical response that was maintained at one-year follow-up. The use of a self-expanding transcatheter bioprosthesis with repositioning features is a solution in cases of valve dislocation to avoid suboptimal positioning of a second implant, especially when the two valves have to be positioned overlapping or partially overlapping each other. Copyright © 2017 Sociedade Portuguesa de Cardiologia. Publicado por Elsevier España, S.L.U. All rights reserved.

  1. Optimal investment and scheduling of distributed energy resources with uncertainty in electric vehicle driving schedules

    International Nuclear Information System (INIS)

    Cardoso, G.; Stadler, M.; Bozchalui, M.C.; Sharma, R.; Marnay, C.; Barbosa-Póvoa, A.; Ferrão, P.

    2014-01-01

    The large scale penetration of electric vehicles (EVs) will introduce technical challenges to the distribution grid, but also carries the potential for vehicle-to-grid services. Namely, if available in large enough numbers, EVs can be used as a distributed energy resource (DER) and their presence can influence optimal DER investment and scheduling decisions in microgrids. In this work, a novel EV fleet aggregator model is introduced in a stochastic formulation of DER-CAM [1], an optimization tool used to address DER investment and scheduling problems. This is used to assess the impact of EV interconnections on optimal DER solutions considering uncertainty in EV driving schedules. Optimization results indicate that EVs can have a significant impact on DER investments, particularly if considering short payback periods. Furthermore, results suggest that uncertainty in driving schedules carries little significance to total energy costs, which is corroborated by results obtained using the stochastic formulation of the problem. - Highlights: • This paper introduces a new EV aggregator model in the DER-CAM model and expands it with a stochastic formulation. • The model is used to analyze the impact of EVs in DER investment decisions in a large office building. • The uncertainty in EV driving patterns is considered through scenarios based on data from a daily commute driving survey. • Results indicate that EVs have a significant impact in optimal DER decisions, particularly when looking at short payback periods. • Furthermore, results indicate that uncertainty in EV driving schedules has little impact on DER investment decisions

  2. Evaluating rare amino acid substitutions (RGC_CAMs in a yeast model clade.

    Directory of Open Access Journals (Sweden)

    Kenneth Polzin

    Full Text Available When inferring phylogenetic relationships, not all sites in a sequence alignment are equally informative. One recently proposed approach that takes advantage of this inequality relies on sites that contain amino acids whose replacement requires multiple substitutions. Identifying these so-called RGC_CAM substitutions (after Rare Genomic Changes as Conserved Amino acids-Multiple substitutions requires that, first, at any given site in the amino acid sequence alignment, there must be a minimum of two different amino acids; second, each amino acid must be present in at least two taxa; and third, the amino acids must require a minimum of two nucleotide substitutions to replace each other. Although theory suggests that RGC_CAM substitutions are expected to be rare and less likely to be homoplastic, the informativeness of RGC_CAM substitutions has not been extensively evaluated in biological data sets. We investigated the quality of RGC_CAM substitutions by examining their degree of homoplasy and internode certainty in nearly 2.7 million aligned amino acid sites from 5,261 proteins from five species belonging to the yeast Saccharomyces sensu stricto clade whose phylogeny is well-established. We identified 2,647 sites containing RGC_CAM substitutions, a number that contrasts sharply with the 100,887 sites containing RGC_non-CAM substitutions (i.e., changes between amino acids that require only a single nucleotide substitution. We found that RGC_CAM substitutions had significantly lower homoplasy than RGC_non-CAM ones; specifically RGC_CAM substitutions showed a per-site average homoplasy index of 0.100, whereas RGC_non-CAM substitutions had a homoplasy index of 0.215. Internode certainty values were also higher for sites containing RGC_CAM substitutions than for RGC_non-CAM ones. These results suggest that RGC_CAM substitutions possess a strong phylogenetic signal and are useful markers for phylogenetic inference despite their rarity.

  3. Model Documentation for the MiniCAM

    Energy Technology Data Exchange (ETDEWEB)

    Brenkert, Antoinette L.; Smith, Steven J.; Kim, Son H.; Pitcher, Hugh M.

    2003-07-17

    The MiniCAM, short for the Mini-Climate Assessment Model, is an integrated assessment model of moderate complexity focused on energy and agriculture sectors. The model produces emissions of greenhouse gases (carbon dioxide, methane and nitrous oxide) and other radiatively important substances such as sulfur dioxide. Through incorporation of the simple climate model MAGICC, the consequences of these emissions for climate change and sea-level rise can be examined. The MiniCAM is designed to be fast and flexible.

  4. Rotary pneumatic valve

    Science.gov (United States)

    Hardee, Harry C.

    1991-01-01

    A rotary pneumatic valve which is thrust balanced and the pneumatic pressure developed produces only radial loads on the valve cylinder producing negligible resistance and thus minimal torque on the bearings of the valve. The valve is multiplexed such that at least two complete switching cycles occur for each revolution of the cylinder spindle.

  5. Treatment Preferences for CAM in Children with Chronic Pain

    OpenAIRE

    Tsao, Jennie C. I.; Meldrum, Marcia; Kim, Su C.; Jacob, Margaret C.; Zeltzer, Lonnie K.

    2006-01-01

    CAM therapies have become increasingly popular in pediatric populations. Yet, little is known about children's preferences for CAM. This study examined treatment preferences in chronic pediatric pain patients offered a choice of CAM therapies for their pain. Participants were 129 children (94 girls) (mean age = 14.5 years ± 2.4; range = 8–18 years) presenting at a multidisciplinary, tertiary clinic specializing in pediatric chronic pain. Bivariate and multivariate analyses were used to examin...

  6. Biodistribution studies of epithelial cell adhesion molecule (EpCAM)-directed monoclonal antibodies in the EpCAM-transgenic mouse tumor model

    NARCIS (Netherlands)

    Kosterink, Jos G. W.; McLaughlin, Pamela M. J.; Lub-de Hooge, Marjolijn N.; Hendrikse, Harry H.; Van Zanten, Jacoba; Van Garderen, Evert; Harmsen, Martin C.; De Leij, Lou F. M. H.

    2007-01-01

    The human pancarcinoma-associated epithelial cell adhesion molecule (EpCAM) (EGP-2, CO17-1A) is a well-known target for carcinoma-directed immunotherapy. Mouse-derived mAbs directed to EpCAM have been used to treat colon carcinoma patients showing well-tolerable toxic side effects but limited

  7. Heavy gas valves

    Energy Technology Data Exchange (ETDEWEB)

    Steier, L [Vereinigte Armaturen Gesellschaft m.b.H., Mannheim (Germany, F.R.)

    1979-01-01

    Heavy gas valves must comply with special requirements. Apart from absolute safety in operation there are stringent requirements for material, sealing and ease of operation even in the most difficult conditions. Ball valves and single plate pipe gate valves lateral sealing rings have a dual, double sided sealing effect according to the GROVE sealing system. Single plate gate valves with lateral protective plates are suitable preferably for highly contaminated media. Soft sealing gate valves made of cast iron are used for low pressure applications.

  8. SenseCam reminiscence and action recall in memory-unimpaired people.

    Science.gov (United States)

    Seamon, John G; Moskowitz, Tacie N; Swan, Ashley E; Zhong, Boyuan; Golembeski, Amy; Liong, Christopher; Narzikul, Alexa C; Sosan, Olumide A

    2014-01-01

    Case studies of memory-impaired individuals consistently show that reminiscing with SenseCam images enhances event recall. This exploratory study examined whether a similar benefit would occur for the consolidation of memories in memory-unimpaired people. We tested delayed recall for atypical actions observed on a lengthy walk. Participants used SenseCam, a diary, or no external memory aid while walking, followed by reminiscence with SenseCam images, diary entries, or no aid, either alone (self-reminiscence) or with the experimenter (social reminiscence). One week later, when tested without SenseCam images or diary entries, prior social reminiscence produced greater recall than self-reminiscence, but there were no differences between memory aid conditions for action free recall or action order recall. When methodological variables were controlled, there was no recall advantage for SenseCam reminiscence with memory-unimpaired participants. The case studies and present study differ in multiple ways, making direct comparisons problematic. SenseCam is a valuable aid to the memory impaired, but its mnemonic value for non-clinical populations remains to be determined.

  9. The application of CAD / CAM technology in Dentistry

    Science.gov (United States)

    Susic, I.; Travar, M.; Susic, M.

    2017-05-01

    Information and communication technologies have found their application in the healthcare sector, including the frameworks of modern dentistry. CAD / CAM application in dentistry is the process by which is attained finished dental restoration through fine milling process of ready ceramic blocks. CAD / CAM is an acronym of english words Computer-Aided-Design (CAD) / Computer-Aided-Manufacture (CAM), respectively dental computer aided design and computer aided manufacture of inlays, onlays, crowns and bridges. CAD / CAM technology essentially allows you to create a two-dimensional and three-dimensional models and their materialization by numerical controlled machines. In order to operate more efficiently, reduce costs, increase user/patient satisfaction and ultimately achieve profits, many dental offices in the world have their attention focused on implementation of modern IT solutions in everyday practice. In addition to the specialized clinic management software, inventory control, etc., or hardware such as the use of lasers in cosmetic dentistry or intraoral scanning, recently the importance is given to the application of CAD / CAM technology in the field of prosthetic. After the removal of pathologically altered tooth structure, it is necessary to achieve restoration that will be most similar to the anatomy of a natural tooth. Applying CAD / CAM technology on applicable ceramic blocks it can be obtained very quick, but also very accurate restoration, in the forms of inlays, onlays, bridges and crowns. The paper presents the advantages of using this technology as well as satisfaction of the patients and dentists by using systems as: Cercon, Celay, Cerec, Lava, Everest, which represent imperative of modern dentistry in creating fixed dental restorations.

  10. Assessment of reliability and maintenance of motor operated valves at Finnish NPPS

    International Nuclear Information System (INIS)

    Laakso, K.; Haenninen, S.; Simola, K.

    1994-01-01

    This paper summarizes two studies on motor operated valve (MOV) failure and maintenance experiences in Finnish nuclear power plants. In the first study, described in section 2 of this paper, the failure reports of MOVs at Finnish BWR units from a nine years' time period were analyzed in a systematic way. The dominant failure mechanisms were identified and time-dependencies in failure occurrence were studied. This study initiated an experience based reliability centered maintenance (RCM) analysis of motor operated valve drives, which is summarized in chapter 3 of this paper. The RCM analysis resulted in the identification and proposal of the most suitable and effective maintenance tasks for consideration. 9 refs, 3 figs, 1 tab

  11. THE RESULTS OF SURGICAL TREATMENT OF TRICUSPID VALVE INFECTIVE ENDOCARDITIS USING VALVE REPAIR AND VALVE REPLACEMENT OPERATIONS

    Directory of Open Access Journals (Sweden)

    S. A. Kovalev

    2015-01-01

    Full Text Available Aim. To evaluate in-hospital and long-term results of surgical treatment of patients with infective endocarditis of the tricuspid valve, to compare the effectiveness of valve repair and valve replacement techniques, and to identify risk factors of mortality and reoperations. Materials and methods. 31 surgical patients with tricuspid valve infective endocarditis were evaluated. Patients were divided into 2 groups. In Group 1 (n = 14 repairs of the tricuspid valve were performed, in Group 2 (n = 17 patients had undergone tricuspid valve replacements. Epidemiological, clinical, microbiological and echocardiographic data were studied. Methods of comparative analysis, the Kaplan–Meier method, and Cox risk models were applied. Results. The most common complication of in-hospital stay was atrioventricular block (17.7% of cases in Group 2. In Group 1, this type of complication was not found. Hospital mortality was 7.14% in Group 1, and 0% in Group 2. Long-term results have shown the significant reduction of heart failure in general cohort and in both groups. In Group 1 the severity of heart failure in the long term was less than in Group 2. No significant differences in the severity of tricuspid regurgitation were found between the groups. In 7-year follow up no cases of death were registered in Group 1. Cumulative survival rate in Group 2 within 60 months was 67.3 ± 16.2%. No reoperations were performed in patients from Group 1. In Group 2, the freedom from reoperation within 60 months was 70.9 ± 15.3%. Combined intervention was found as predictor of postoperative mortality. Prosthetic valve endocarditis was identified as risk factor for reoperation. Conclusion. Valve repair and valve replacement techniques of surgical treatment of tricuspid valve endocarditis can provide satisfactory hospital and long-term results. Tricuspid valve repair techniques allowed reducing the incidence of postoperative atrioventricular block. In the long-term, patients

  12. The Role of Th17 in Neuroimmune Disorders: Target for CAM Therapy. Part II

    Directory of Open Access Journals (Sweden)

    Aristo Vojdani

    2011-01-01

    Full Text Available Decades of research went into understanding the role that Th1 autoreactive T-cells play in neuroinflammation. Here we describe another effector population, the IL-17-producing T-helper lineage (Th17, which drives the inflammatory process. Through the recruitment of inflammatory infiltration neutrophils and the activation of matrix metalloproteinases, IL-17, a cytokine secreted by Th17 cells, contributes to blood-brain barrier breakdown and the subsequent attraction of macrophages and monocytes into the nervous system. The entry of cells along with the local production of inflammatory cytokines leads to myelin and axonal damage. This activation of the inflammatory response system is induced by different pathogenic factors, such as gut bacterial endotoxins resulting in progressive neurodegeneration by Th17 cells. Through the understanding of the role of bacterial endotoxins and other pathogenic factors in the induction of autoimmune diseases by Th17 cells, CAM practitioners will be able to design CAM therapies targeting IL-17 activity. Targeted therapy can restore the integrity of the intestinal and blood-brain barriers using probiotics, N-acetyl-cysteine, α-lipoic acid, resveratrol and others for their patients with autoimmunities, in particular those with neuroinflammation and neurodegeneration.

  13. Effectiveness of CAM therapy: understanding the evidence.

    Science.gov (United States)

    Staud, Roland

    2011-02-01

    By definition, complementary and alternative medicine (CAM) attempts to diagnose and treat illnesses in unconventional ways. CAM has been classified as: (1) alternative medical systems (eg, traditional Chinese medicine [including acupuncture], naturopathic medicine, ayurvedic medicine, and homeopathy); (2) biologic-based therapies (eg, herbal, special dietary, and individual biologic treatments); (3) energy therapies (eg, Reiki, therapeutic touch, magnet therapy, Qi Gong, and intercessory prayer); (4) manipulative and body-based systems (eg, chiropractic, osteopathy, and massage); and (5) mind-body interventions (eg, meditation, biofeedback, hypnotherapy, and the relaxation response). This review focuses on how to assess the effectiveness of CAM therapies for chronic musculoskeletal pains, emphasizing the role of specific and nonspecific analgesic mechanisms, including placebo. Copyright © 2011 Elsevier Inc. All rights reserved.

  14. Prevalence of Cam Morphology in Females with Femoroacetabular Impingement

    Directory of Open Access Journals (Sweden)

    David M Levy

    2015-12-01

    Full Text Available Cam and pincer are two common morphologies responsible for femoroacetabular impingement. Previous literature has reported that cam deformity is predominantly a male morphology, while being significantly less common in females. The purpose of this study was to determine the prevalence of cam morphology in female subjects diagnosed with symptomatic FAI. All females presenting to the senior author’s clinic diagnosed with symptomatic FAI between December 2006 and Cam and pincer are two common morphologies responsible for femoroacetabular impingement. Previous literature has reported that cam deformity is predominantly a male morphology, while being significantly less common in females. Cam morphology is commonly assessed with the alpha angle, measured on radiographs. The purpose of this study was to determine the prevalence of cam morphology utilizing the alpha angle in female subjects diagnosed with symptomatic FAI. All females presenting to the senior author’s clinic diagnosed with symptomatic FAI between December 2006 and January 2013 were retrospectively reviewed. Alpha (α angles were measured on AP (anteroposterior and lateral (Dunn 90°, cross-table lateral, and/or frog-leg lateral plain radiographs by two blinded physicians, and the largest measured angle was used. Using Gosvig et al.’s classification, alpha angle was characterized as (pathologic > 57°, borderline (51-56°, subtle (46-50°, very subtle (43-45°, or normal (≤42°. Three hundred and ninety-one patients (438 hips were analyzed (age 36.2 ± 12.3 years. Among the hips included, 35.6% were normal, 14.6% pathologic, 15.1% borderline, 14.6% subtle, and 20.1% very subtle. There was no correlation between alpha angle and patient age (R = 0.17 or body mass index (BMI (R = 0.05. The intraclass correlation coefficient (ICC for α-angle measurements was 0.84. Sixty-four percent of females in this cohort had an alpha angle > 42°. Subtle cam deformity plays a significant role in

  15. CAM for Pediatric Pain: What is State-of-the-Research?

    Directory of Open Access Journals (Sweden)

    Jennie C. I. Tsao

    2006-01-01

    Full Text Available Previously, we reviewed the evidence for the efficacy of CAM approaches for pediatric pain (volume 2; issue 2; 2005 using criteria developed by the American Psychological Association Division 12 Task Force. Our review focused on CAM modalities that had been tested with at least one controlled trial or multiple baseline study. In addition, only those trials in which children comprised the study sample were included. Thus, several CAM modalities were not included in our review. Key ethical and other reasons for the limited literature on CAM for pediatric pain as well as directions for future studies are discussed.

  16. An Innovative Radiation Hardened CAM Architecture

    CERN Document Server

    Shojaii, Seyed Ruhollah; The ATLAS collaboration

    2018-01-01

    This article describes an innovative Content Addressable Memory (CAM) cell with radiation hardened (RH) architecture. The RH-CAM is designed in a commercial 28 nm CMOS technology. The circuit has been simulated in worst-case conditions, and the effects due to single particles have been analyzed by injecting a current pulse into a circuit node. The proposed architecture is suitable for on-time pattern recognition tasks in harsh environments, such as front-end electronics in hadron colliders and in space applications.

  17. Variable valve timing in a homogenous charge compression ignition engine

    Science.gov (United States)

    Lawrence, Keith E.; Faletti, James J.; Funke, Steven J.; Maloney, Ronald P.

    2004-08-03

    The present invention relates generally to the field of homogenous charge compression ignition engines, in which fuel is injected when the cylinder piston is relatively close to the bottom dead center position for its compression stroke. The fuel mixes with air in the cylinder during the compression stroke to create a relatively lean homogeneous mixture that preferably ignites when the piston is relatively close to the top dead center position. However, if the ignition event occurs either earlier or later than desired, lowered performance, engine misfire, or even engine damage, can result. The present invention utilizes internal exhaust gas recirculation and/or compression ratio control to control the timing of ignition events and combustion duration in homogeneous charge compression ignition engines. Thus, at least one electro-hydraulic assist actuator is provided that is capable of mechanically engaging at least one cam actuated intake and/or exhaust valve.

  18. Use of Complementary and Alternative Medicine (CAM) as Part of the Oncological Treatment: Survey about Patients? Attitude towards CAM in a University-Based Oncology Center in Germany

    OpenAIRE

    Kessel, Kerstin A.; Lettner, Sabrina; Kessel, Carmen; Bier, Henning; Biedermann, Tilo; Friess, Helmut; Herrschbach, Peter; Gschwend, J?rgen E.; Meyer, Bernhard; Peschel, Christian; Schmid, Roland; Schwaiger, Markus; Wolff, Klaus-Dietrich; Combs, Stephanie E.

    2016-01-01

    Introduction To understand if and which patients would be open-minded to Complementary and Alternative Medicine (CAM) use parallel to their oncological treatment. Moreover, we sought to determine which methods are most accepted and which are the primary motivators to use CAM. Methods We developed and anonymously conducted a questionnaire for patients in the oncology center (TU Munich). Questions focus on different CAM methods, previous experiences, and willingness to apply or use CAM when off...

  19. Camões e a cosmogonia

    Science.gov (United States)

    Costa, J. M.

    2003-08-01

    Os Lusíadas, escrito por Luis de Camões em 1572, é um poema épico renascentista e a visão Cosmogônica do autor é apresentada, principalmente, no último canto do poema, quando Tétis mostra ao Gama a Máquina do Mundo. A Cosmogonia de Camões neste poema reflete uma visão de uma época de transição, que ainda não incorporou os elementos da revolução Copernicana. É uma visão Grego- Ptolomaica e também medieval. O poeta guia-se pela tradução e notas feita por Pedro Nunes, inventor do Nonio, do Tratado da Esfera "De Sphaera" do Astrônomo Inglês John Holywood, mais conhecido pelo nome latinizado de Johannes Sacrobosco. Outra provável fonte de Camões, de acordo com Luciano Antonio Pereira da Silva em Astronomia de os Lusíadas, é o "Theoricae novae Planetarum" (1460) do astrólogo Alemão Jorge Purbáquio (1423 - 1461). A Astronomia de Os Lusíadas representa a ciência do tempo de Camões. Camões nunca emprega a palavra constelação e seu catálogo é bastante completo. A Máquina do Mundo tem a Terra no centro. Em redor, em círculos concêntricos, a lua (Diana), Mercúrio, Vênus, o Sol (Febo), Marte, Júpiter e Saturno. Envolvendo estes astros tem o firmamento seguido pelo "Céu Áqueo" ou cristalino, depois o 1o Móbil, esfera que arrasta todas as outras consigo. Este trabalho, multidisciplinar, serve tanto para ensinar aos alunos da Física como das Ciências Humanas, a concepção de mundo do renascimento de uma forma belamente poética em versos decassílabos Este trabalho também ajuda na apreciação do maior clássico da língua portuguesa e mostra como as Ciências e as artes, em geral, estão correlacionadas e refletem a visão de mundo da época em que foi produzida.

  20. Use of EyeCam for imaging the anterior chamber angle.

    Science.gov (United States)

    Perera, Shamira A; Baskaran, Mani; Friedman, David S; Tun, Tin A; Htoon, Hla M; Kumar, Rajesh S; Aung, Tin

    2010-06-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) imaging with gonioscopy for detecting angle closure. In this prospective, hospital-based study, subjects underwent gonioscopy by a single observer and EyeCam imaging by a different operator. EyeCam images were graded by two masked observers. The anterior chamber angle in a quadrant was classified as closed if the trabecular meshwork could not be seen. The eye was classified as having angle closure if two or more quadrants were closed. One hundred fifty-two subjects were studied. The mean age was 57.4 years (SD 12.9) and there were 82 (54%) men. Of the 152 eyes, 21 (13.8%) had angle closure. The EyeCam provided clear images of the angles in 98.8% of subjects. The agreement between the EyeCam and gonioscopy for detecting angle closure in the superior, inferior, nasal, and temporal quadrants based on agreement coefficient (AC1) statistics was 0.73, 0.75, 0.76, and 0.72, respectively. EyeCam detected more closed angles than did gonioscopy in all quadrants (P gonioscopy, 21/152 (13.8%) eyes were diagnosed as angle closure compared to 41 (27.0%) of 152 with EyeCam (P gonioscopy for detecting angle closure. However, it detected more closed angles than did gonioscopy in all quadrants.

  1. Biofuel crops with CAM photosynthesis: Economic potential on moisture-limited lands

    Science.gov (United States)

    Bartlett, Mark; Hartzell, Samantha; Porporato, Amilcare

    2017-04-01

    As the demand for food and renewable energy increases, the intelligent utilization of marginal lands is becoming increasingly critical. In marginal lands classified by limited rainfall or soil salinity, the cultivation of traditional C3 and C4 photosynthesis crops often is economically infeasible. However, in such lands, nontraditional crops with crassulacean acid metabolism (CAM) photosynthesis show great economic potential for cultivation. CAM crops including Opuntia (prickly pear) and Ananas (pineapple) achieve a water use efficiency which is three fold higher than C4 crops such as corn and 6-fold higher than C3 crops such as wheat, leading to a comparable annual productivity with only 20% of the water demand. This feature, combined with a shallow rooting depth and a high water storage capacity, allows CAM plants to take advantage of small, infrequent rainfall amounts in shallow, quickly draining soils. Furthermore, CAM plants typically have properties (e.g., high content of non-structural carbohydrates) that are favorable for biofuel production. Here, for marginal lands characterized by low soil moisture availability and/or high salinity, we assess the potential productivity and economic benefits of CAM plants. CAM productivity is estimated using a recently developed model which simulates CAM photosynthesis under a range of soil and climate conditions. From these results, we compare the energy and water resource inputs required by CAM plants to those required by more traditional C3 and C4 crops (corn, wheat, sorghum), and we evaluate the economic potential of CAM crops as sources of food, fodder, or biofuel in marginal soils. As precipitation events become more intense and infrequent, we show that even though marginal land area may increase, CAM crop cultivation shows great promise for maintaining high productivity with minimal water inputs. Our analysis indicates that on marginal lands, widespread cultivation of CAM crops as biofuel feedstock may help

  2. Force measuring valve assemblies, systems including such valve assemblies and related methods

    Science.gov (United States)

    DeWall, Kevin George [Pocatello, ID; Garcia, Humberto Enrique [Idaho Falls, ID; McKellar, Michael George [Idaho Falls, ID

    2012-04-17

    Methods of evaluating a fluid condition may include stroking a valve member and measuring a force acting on the valve member during the stroke. Methods of evaluating a fluid condition may include measuring a force acting on a valve member in the presence of fluid flow over a period of time and evaluating at least one of the frequency of changes in the measured force over the period of time and the magnitude of the changes in the measured force over the period of time to identify the presence of an anomaly in a fluid flow and, optionally, its estimated location. Methods of evaluating a valve condition may include directing a fluid flow through a valve while stroking a valve member, measuring a force acting on the valve member during the stroke, and comparing the measured force to a reference force. Valve assemblies and related systems are also disclosed.

  3. Scleroderma, Stress and CAM Utilization

    Directory of Open Access Journals (Sweden)

    Ka-Kit Hui

    2009-01-01

    Full Text Available Scleroderma is an autoimmune disease influenced by interplay among genetic and environmental factors, of which one is stress. Complementary and alternative medicine (CAM is frequently used to treat stress and those diseases in which stress has been implicated. Results are presented from a survey of patients with scleroderma. Respondents were a convenient sample of those attending a national conference in Las Vegas in 2002. Findings implicate stress in the onset, continuation and exacerbation of scleroderma. The implication is that CAM providers may be filling an important patient need in their provision of services that identify and treat stress and its related disorders.

  4. Magnetically operated check valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-06-01

    A magnetically operated check valve is disclosed. The valve is comprised of a valve body and a movable poppet disposed therein. A magnet attracts the poppet to hold the valve shut until the force of fluid flow through the valve overcomes the magnetic attraction and moves the poppet to an unseated, open position. The poppet and magnet are configured and disposed to trap a magnetically attracted particulate and prevent it from flowing to a valve seating region.

  5. Trend and application of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-09-01

    This report is about trend and application of CAD/CAM system, giving descriptions of computer aided design which helps construction, engineering and drafting tasks. It also tells of computer aided manufacturing related general design of manufactures, which includes process design, production management, decision of work technology, processing. The need and application of CAD/CAM system is increasing more and more for industry each area.

  6. A remote control valve

    International Nuclear Information System (INIS)

    Cachard, Maurice de; Dumont, Maurice.

    1976-01-01

    This invention concerns a remote control valve for shutting off or distributing a fluid flowing at a high rate and low pressure. Among the different valves at present in use, electric valves are the most recommended for remote control but their reliability is uncertain and they soon become costly when large diameter valves are used. The valve described in this invention does away with this drawback owing to its simplicity and the small number of moving parts, this makes it particularly reliable. It mainly includes: a tubular body fitted with at least one side opening; at least one valve wedge for this opening, coaxial with the body, and mobile; a mobile piston integral with this wedge. Several valves to the specifications of this invention can be fitted in series (a shut-off valve can be used in conjunction with one or more distribution valves). The fitting and maintenance of the valve is very simple owing to its design. It can be fabricated in any material such as metals, alloys, plastics and concrete. The structure of the valve prevents the flowing fluid from coming into contact with the outside environment, thereby making it particularly suitable in the handling of dangerous or corrosive fluids. Finally, the opening and shutting of the valve occurs slowly, thereby doing away with the water hammer effect so frequent in large bore pipes [fr

  7. Angle assessment by EyeCam, goniophotography, and gonioscopy.

    Science.gov (United States)

    Baskaran, Mani; Perera, Shamira A; Nongpiur, Monisha E; Tun, Tin A; Park, Judy; Kumar, Rajesh S; Friedman, David S; Aung, Tin

    2012-09-01

    To compare EyeCam (Clarity Medical Systems, Pleasanton, CA) and goniophotography in detecting angle closure, using gonioscopy as the reference standard. In this hospital-based, prospective, cross-sectional study, participants underwent gonioscopy by a single observer, and EyeCam imaging and goniophotography by different operators. The anterior chamber angle in a quadrant was classified as closed if the posterior trabecular meshwork could not be seen. A masked observer categorized the eyes as per the number of closed quadrants, and an eye was classified as having angle closure if there were 2 or more quadrants of closure. Agreement between the methods was analyzed by κ statistic and comparison of area under receiver operating characteristic curves (AUC). Eighty-five participants (85 eyes) were included, the majority of whom were Chinese. Angle closure was detected in 38 eyes (45%) with gonioscopy, 40 eyes (47%) using EyeCam, and 40 eyes (47%) with goniophotography (P=0.69 in both comparisons, McNemar test). The agreement for angle closure diagnosis (by eye) between gonioscopy and the 2 imaging modalities was high (κ=0.86; 95% Confidence Interval (CI), 0.75-0.97), whereas the agreement between EyeCam and goniophotography was not as good (κ=0.72; 95% CI, 0.57-0.87); largely due to lack of agreement in the nasal and temporal quadrants (κ=0.55 to 0.67). The AUC for detecting eyes with gonioscopic angle closure was similar for goniophotography and EyeCam (AUC 0.93, sensitivity=94.7%, specificity=91.5%; P>0.95). EyeCam and goniophotography have similarly high sensitivity and specificity for the detection of gonioscopic angle closure.

  8. Infective Endocarditis of the Aortic Valve with Anterior Mitral Valve Leaflet Aneurysm

    NARCIS (Netherlands)

    Tomsic, Anton; Li, Wilson W. L.; van Paridon, Marieke; Bindraban, Navin R.; de Mol, Bas A. J. M.

    2016-01-01

    Mitral valve leaflet aneurysm is a rare and potentially devastating complication of aortic valve endocarditis. We report the case of a 48-year-old man who had endocarditis of the native aortic valve and a concomitant aneurysm of the anterior mitral valve leaflet. Severe mitral regurgitation occurred

  9. Effect of co-free valve on activity reduction in PWR

    International Nuclear Information System (INIS)

    Bahn, C.B.; Han, B.C.; Bum, J.S.; Hwang, I.S.; Lee, C.B.

    2002-01-01

    Radioactive nuclei, such as 68 Co and 60 Co, deposited on out-of-core surfaces in a pressurized water reactor (PWR) primary coolant system, are major sources of occupational radiation exposure to plant maintenance personnel and act as costly impediment to prompt and effective repairs. Valve hardfacing alloys exposed to primary coolant are considered as one of the main Co sources. To evaluate the Co-free valve, such as NOREM 02 and Deloro 50, the candidates for the alternative to Stellite 6, in a simulated PWR primary condition, SNU corrosion test loop (SCOTL) was constructed. For gate valves hard-faced with made of NOREM 02 and Deloro 50 hot cycling tests were conducted for up to 2,000 on-off cycles with cold leak tests at 1,000 cycle interval. It was observed that the leak rate of NOREM 02 (Fe-base) did not satisfy the nuclear grade valve leak criteria. After 1000 cycles test, while there was no leakage in case of Deloro 50 (Ni-base). Also, Deloro 50 showed no leakage after 2000 cycles. To estimate the activity reduction effect, we modified CRUDSIM-MIT which modeled the effects of coolant chemistry on the crud transport and activity buildup in the primary system of PWR. In the new code, crud evaluation and assessment (CREAT), 60 Co activity buildup prediction includes 1) Co-base valve replacement effect, 2) Co-base valve maintenance effect, and 3) control rod drive mechanism (CRDM) and main coolant pump (MCP) shaft contribution. CREAT predicted that the main contributor of Co activity buildup was the corrosion-induced release of Co from the steam generator (SG) tubing. With new SG's tubed with alloy 690, Korean Next Generation Reactor (APR-1400) is expected to have about 64% lower Co activity on SG surface. The use of all Co-free valves is expected to cut additional 8% of activity which is only marginal. (authors)

  10. Aortic valve insufficiency in the teenager and young adult: the role of prosthetic valve replacement.

    Science.gov (United States)

    Bradley, Scott M

    2013-10-01

    The contents of this article were presented in the session "Aortic insufficiency in the teenager" at the congenital parallel symposium of the 2013 Society of Thoracic Surgeons (STS) annual meeting. The accompanying articles detail the approaches of aortic valve repair and the Ross procedure.(1,2) The current article focuses on prosthetic valve replacement. For many young patients requiring aortic valve surgery, either aortic valve repair or a Ross procedure provides a good option. The advantages include avoidance of anticoagulation and potential for growth. In other patients, a prosthetic valve is an appropriate alternative. This article discusses the current state of knowledge regarding mechanical and bioprosthetic valve prostheses and their specific advantages relative to valve repair or a Ross procedure. In current practice, young patients requiring aortic valve surgery frequently undergo valve replacement with a prosthetic valve. In STS adult cardiac database, among patients ≤30 years of age undergoing aortic valve surgery, 34% had placement of a mechanical valve, 51% had placement of a bioprosthetic valve, 9% had aortic valve repair, and 2% had a Ross procedure. In the STS congenital database, among patients 12 to 30 years of age undergoing aortic valve surgery, 21% had placement of a mechanical valve, 18% had placement of a bioprosthetic valve, 30% had aortic valve repair, and 24% had a Ross procedure. In the future, the balance among these options may be altered by design improvements in prosthetic valves, alternatives to warfarin, the development of new patch materials for valve repair, and techniques to avoid Ross autograft failure.

  11. Temporal and spatial transcriptomic and microRNA dynamics of CAM photosynthesis in pineapple.

    Science.gov (United States)

    Wai, Ching M; VanBuren, Robert; Zhang, Jisen; Huang, Lixian; Miao, Wenjing; Edger, Patrick P; Yim, Won C; Priest, Henry D; Meyers, Blake C; Mockler, Todd; Smith, J Andrew C; Cushman, John C; Ming, Ray

    2017-10-01

    The altered carbon assimilation pathway of crassulacean acid metabolism (CAM) photosynthesis results in an up to 80% higher water-use efficiency than C 3 photosynthesis in plants making it a potentially useful pathway for engineering crop plants with improved drought tolerance. Here we surveyed detailed temporal (diel time course) and spatial (across a leaf gradient) gene and microRNA (miRNA) expression patterns in the obligate CAM plant pineapple [Ananas comosus (L.) Merr.]. The high-resolution transcriptome atlas allowed us to distinguish between CAM-related and non-CAM gene copies. A differential gene co-expression network across green and white leaf diel datasets identified genes with circadian oscillation, CAM-related functions, and source-sink relations. Gene co-expression clusters containing CAM pathway genes are enriched with clock-associated cis-elements, suggesting circadian regulation of CAM. About 20% of pineapple microRNAs have diel expression patterns, with several that target key CAM-related genes. Expression and physiology data provide a model for CAM-specific carbohydrate flux and long-distance hexose transport. Together these resources provide a list of candidate genes for targeted engineering of CAM into C 3 photosynthesis crop species. © 2017 The Authors The Plant Journal © 2017 John Wiley & Sons Ltd.

  12. Transcatheter aortic valve-in-valve treatment of degenerative stentless supra-annular Freedom Solo valves: A single centre experience.

    Science.gov (United States)

    Cockburn, James; Dooley, Maureen; Parker, Jessica; Hill, Andrew; Hutchinson, Nevil; de Belder, Adam; Trivedi, Uday; Hildick-Smith, David

    2017-02-15

    Redo surgery for degenerative bioprosthetic aortic valves is associated with significant morbidity and mortality. Report results of valve-in-valve therapy (ViV-TAVI) in failed supra-annular stentless Freedom Solo (FS) bioprostheses, which are the highest risk for coronary occlusion. Six patients with FS valves (mean age 78.5 years, 50% males). Five had valvular restenosis (peak gradient 87.2 mm Hg, valve area 0.63 cm 2 ), one had severe regurgitation (AR). Median time to failure was 7 years. Patients were high risk (mean STS/Logistic EuroScore 10.6 15.8, respectively). FS valves ranged from 21 to 25 mm. Successful ViV-TAVI was achieved in 4/6 patients (67%). Of the unsuccessful cases, (patient 1 and 2 of series) patient 1 underwent BAV with simultaneous aortography which revealed left main stem occlusion. The procedure was stopped and the patient went forward for repeat surgery. Patient 2 underwent successful ViV-TAVI with a 26-mm CoreValve with a guide catheter in the left main, but on removal coronary obstruction occurred, necessitating valve snaring into the aorta. Among the successful cases, (patients 3, 4, 5, 6) the TAVIs used were CoreValve Evolut R 23 mm (n = 3), and Lotus 23 mm (n = 1). In the successful cases the peak gradient fell from 83.0 to 38.3 mm Hg. No patient was left with >1+ AR. One patient had a stroke on Day 2, with full neurological recovery. Two patients underwent semi-elective pacing for LBBB and PR >280 ms. ViV-TAVI in stentless Freedom Solo valves is high risk. The risk of coronary occlusion is high. The smallest possible prosthesis (1:1 sizing) should be used, and strategies to protect the coronary vessels must be considered. © 2016 Wiley Periodicals, Inc. © 2016 Wiley Periodicals, Inc.

  13. Application of diagnostics to determine motor operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  14. Application of diagnostics to determine motor-operated valve operational readiness

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1986-01-01

    ORNL has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor curent signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  15. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  16. Which valve is which?

    Directory of Open Access Journals (Sweden)

    Pravin Saxena

    2015-01-01

    Full Text Available A 25-year-old man presented with a history of breathlessness for the past 2 years. He had a history of operation for Tetralogy of Fallot at the age of 5 years and history suggestive of Rheumatic fever at the age of 7 years. On echocardiographic examination, all his heart valves were severely regurgitating. Morphologically, all the valves were irreparable. The ejection fraction was 35%. He underwent quadruple valve replacement. The aortic and mitral valves were replaced by metallic valve and the tricuspid and pulmonary by tissue valve.

  17. Mitral Valve Prolapse

    Science.gov (United States)

    Mitral valve prolapse (MVP) occurs when one of your heart's valves doesn't work properly. The flaps of the valve are "floppy" and ... to run in families. Most of the time, MVP doesn't cause any problems. Rarely, blood can ...

  18. Maximizing prosthetic valve size with the Top Hat supra-annular aortic valve

    DEFF Research Database (Denmark)

    Aagaard, Jan; Geha, Alexander S.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The CarboMedics Top Hat supra-annular aortic valve allows a one-size (and often two-size) increase over the standard intra-annular valve. This advantage should minimize the risk of patient-prosthesis mismatch, where the effective prosthetic valve orifice area....... This study evaluates the authors' clinical experience with Top Hat supra-annular aortic valve size selection, and the technical aspects of implantation. METHODS: Between January 1999 and October 2005, a total of 251 consecutive patients underwent 252 aortic valve replacements with Top Hat supra...... required unplanned coronary bypass, and 30-day mortality was 2.0% (5/251), indicating a good safety profile for the valves implanted in this series. CONCLUSION: The general distribution of implant sizes in the US indicates that cardiac surgeons may be under-sizing the Top Hat supra-annular aortic valve...

  19. A review of complementary and alternative medicine (CAM) by people with multiple sclerosis.

    Science.gov (United States)

    Olsen, Sherri A

    2009-01-01

    Multiple sclerosis (MS) is a chronic, unpredictable disease of the central nervous system without a known cure. Because of this, people with MS often seek complementary and alternative medicines (CAM) to manage their disease symptoms. The goal of this review article was to describe the use of CAM by individuals diagnosed with MS. Evidence was obtained by searching Medline (1950-2007), EBSCOhost and PubMed for studies relating CAM to MS. Results from the literature showed that people with MS reported that they used CAM from 27 to 100%. The major reasons for choosing CAM were as follows: conventional treatment was not effective, anecdotal reports of CAM's help, and doctor referral. The types of CAM reported by people with MS included exercise, vitamins, herbal and mineral supplements, relaxation techniques, acupuncture, cannabis and massage. The major symptoms treated by CAM as noted in the literature were pain, fatigue and stress. There is a need for further research to evaluate the effectiveness of CAM with MS patients and their application by occupational therapists. The limitation of this literature review was the low response rate in many of the surveys reported. 2009 John Wiley & Sons, Ltd

  20. Development of a compact wearable pneumatic drive unit for a ventricular assist device.

    Science.gov (United States)

    Homma, Akihiko; Taenaka, Yoshiyuki; Tatsumi, Eisuke; Akagawa, Eiki; Lee, Hwansung; Nishinaka, Tomohiro; Takewa, Yoshiaki; Mizuno, Toshihide; Tsukiya, Tomonori; Kakuta, Yukihide; Katagiri, Nobumasa; Shimosaki, Isao; Hamada, Shigeru; Mukaibayashi, Hiroshi; Iwaoka, Wataru

    2008-01-01

    The purpose of this study was to develop a compact wearable pneumatic drive unit for a ventricular assist device (VAD). This newly developed drive unit, 20 x 8.5 x 20 cm in size and weighing approximately 1.8 kg, consists of a brushless DC motor, noncircular gears, a crankshaft, a cylinder-piston, and air pressure regulation valves. The driving air pressure is generated by the reciprocating motion of the piston and is controlled by the air pressure regulation valves. The systolic ratio is determined by the noncircular gears, and so is fixed for a given configuration. As a result of an overflow-type mock circulation test, a drive unit with a 44% systolic ratio connected to a Toyobo VAD blood pump with a 70-ml stroke volume achieved a pump output of more than 7 l/min at 100 bpm against a 120 mmHg afterload. Long-term animal tests were also performed using drive units with systolic ratios of 45% and 53% in two Holstein calves weighing 62 kg and 74 kg; the tests were terminated on days 30 and 39, respectively, without any malfunction. The mean aortic pressure, bypass flow, and power consumption for the first calf were maintained at 90 x 13 mmHg, 3.9 x 0.9 l/min, and 12 x 1 W, and those for the second calf were maintained at 88 x 13 mmHg, 5.0 x 0.5 l/min, and 16 x 2 W, respectively. These results indicate that the newly developed drive unit may be used as a wearable pneumatic drive unit for the Toyobo VAD blood pump.

  1. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  2. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma.

    Science.gov (United States)

    Azad, Raj V; Chandra, Parijat; Chandra, Anuradha; Gupta, Aparna; Gupta, Viney; Sihota, Ramanjit

    2014-02-01

    To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Image clarity, interobserver agreement. 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  3. Heart Valve Diseases

    Science.gov (United States)

    Your heart has four valves. Normally, these valves open to let blood flow through or out of your heart, and then shut to keep it from flowing ... close tightly. It's one of the most common heart valve conditions. Sometimes it causes regurgitation. Stenosis - when ...

  4. Prosthetic valve endocarditis after transcatheter aortic valve implantation

    DEFF Research Database (Denmark)

    Olsen, Niels Thue; De Backer, Ole; Thyregod, Hans G H

    2015-01-01

    BACKGROUND: Transcatheter aortic valve implantation (TAVI) is an advancing mode of treatment for inoperable or high-risk patients with aortic stenosis. Prosthetic valve endocarditis (PVE) after TAVI is a serious complication, but only limited data exist on its incidence, outcome, and procedural......%) were treated conservatively and 1 with surgery. Four patients (22%) died from endocarditis or complications to treatment, 2 of those (11%) during initial hospitalization for PVE. An increased risk of TAVI-PVE was seen in patients with low implanted valve position (hazard ratio, 2.8 [1.1-7.2]), moderate...

  5. Family medicine residency program directors attitudes and knowledge of family medicine CAM competencies.

    Science.gov (United States)

    Gardiner, Paula; Filippelli, Amanda C; Lebensohn, Patricia; Bonakdar, Robert

    2013-01-01

    Little is known about the incorporation of integrative medicine (IM) and complementary and alternative medicine (CAM) into family medicine residency programs. The Society for Teachers of Family Medicine (STFM) approved a set of CAM/IM competencies for family medicine residencies. We hope to evaluate whether residency programs are implementing such competencies into their curriculum using an online survey tool. We also hope to assess the knowledge and attitudes of Residency Directors (RDs) on the CAM/IM competencies. A survey was distributed by the Council of Academic Family Medicine (CAFM) Educational Research Alliance to RDs via e-mail. The survey was distributed to 431 RDs. Of those who received it, 212 responded, giving a response rate of 49.1%. Questions assessed the knowledge and attitudes of CAM/IM competencies and incorporation of CAM/IM into the residency curriculum. Forty-five percent of RDs were aware of the competencies. In terms of RD attitudes, 58% reported that CAM/IM is an important component of residents' curriculum; yet, 60% report not having specific learning objectives for CAM/IM in their residency curriculum. Among all programs, barriers to CAM/IM implementation included time in residents' schedules (77%); faculty training (75%); access to CAM experts (43%); lack of reimbursement (43%); and financial resources (29%). While many RDs are aware of the STFM CAM/IM competencies and acknowledge their role in residence education, there are many barriers that prevent residencies from implementing the STFM CAM/IM competencies. © 2013 Elsevier Inc. All rights reserved.

  6. Validation of CLIC Re-Adjustment System Based on Eccentric Cam Movers One Degree of Freedom Mock-Up

    CERN Document Server

    Kemppinen, J; Lackner, F

    2011-01-01

    Compact Linear Collider (CLIC) is a 48 km long linear accelerator currently studied at CERN. It is a high luminosity electron-positron collider with an energy range of 0.5-3 TeV. CLIC is based on a two-beam technology in which a high current drive beam transfers RF power to the main beam accelerating structures. The main beam is steered with quadrupole magnets. To reach CLIC target luminosity, the main beam quadrupoles have to be actively pre-aligned within 17 µm in 5 degrees of freedom and actively stabilised at 1 nm in vertical above 1 Hz. To reach the pre-alignment requirement as well as the rigidity required by nano-stabilisation, a system based on eccentric cam movers is proposed for the re-adjustment of the main beam quadrupoles. Validation of the technique to the stringent CLIC requirements was started with tests in one degree of freedom on an eccentric cam mover. This paper describes the dedicated mock-up as well as the tests and measurements carried out with it. Finally, the test results are present...

  7. Integration of CAM and CNC operation through code editing and manipulation

    International Nuclear Information System (INIS)

    Rosli Darmawan; Shalina Sheik Muhammad

    2004-01-01

    The IT technology for engineering design and manufacturing has gone through significant advancement for the last 30 years. It is widely acknowledged that IT would provide competitive advantage for engineering company in term of production cycle, productivity and efficiency. The recent development in this area is on the total system integration. While standard off-shelf CAD/CAM/CNC software and hardware packages would provide solution for system integration, more often than not users will stumble upon compatibility problems. Moreover, most of the integration deals with CAD and CAM systems. CNC integration has not been fully developed. Users always found problems in the integration of CAM and CNC machine due to the different level of technological development. CNC codes have not fundamentally progressed in the last 50 years, while CAD/CAM software packages have undergone massive evolution and improvement. This paper discusses a practical solution of CAM and CNC integration through code editing and manipulation within the CAM system in order to comply with the CNC machine requirements. (Author)

  8. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  9. Pattern and predictors of complementary and alternative medicine (CAM) use among pediatric patients with epilepsy.

    Science.gov (United States)

    Doering, Jan H; Reuner, Gitta; Kadish, Navah E; Pietz, Joachim; Schubert-Bast, Susanne

    2013-10-01

    Parents of pediatric patients with chronic conditions such as epilepsy increasingly opt for complementary and alternative medicine (CAM). However, data on the pattern and reasons of CAM use in childhood epilepsy are scarce. The objectives of this study were as follows: first, to characterize CAM use among pediatric patients with epilepsy by assessing its spectrum, prevalence, costs, and frequency of use; second, to evaluate the influence of CAM use on compliance and satisfaction with conventional care as well as to explore parent-child neurologist communication concerning CAM; and third, to investigate predictors of CAM use. A postal survey was administered to all parents of pediatric outpatients with epilepsy aged 6 to 12, who have received treatment at the neuropediatric outpatient clinic of the University Children's Hospital Heidelberg between 2007 and 2009. One hundred thirty-two of the 297 distributed questionnaires were suitable for inclusion in statistical analysis (44.7%). Forty-nine participants indicated that their children used CAM during the previous year (37.1%). Thirty different types of CAM were used, with homeopathy (55.1%), osteopathy (24.5%), and kinesiology (16.3%) being the most commonly named. A mean of 86€ (0€-500€) and 3h (1 h-30 h) per month was committed to CAM treatment. Only 53% of the users informed their child neurologist of the additional CAM treatment, while 85.6% of all parents wished to discuss CAM options with their child neurologist. Seventy-five percent of users considered the CAM treatment effective. Among the participants most likely to seek CAM treatment are parents whose children show a long duration of epileptic symptoms, parents who make use of CAM treatment themselves, and parents who value a holistic and natural treatment approach. A substantial portion of pediatric patients with epilepsy receive CAM treatment. The high prevalence of use and significant level of financial and time resources spent on CAM indicate the

  10. Incorporation of CAD/CAM Restoration Into Navy Dentistry

    Science.gov (United States)

    2017-09-26

    CAD/CAM Computer-aided design /Computer-assisted manufacturing CDT Common Dental Terminology DENCAS Dental Common Access System DTF Dental...to reduce avoidable dental emergencies for deployed sailors and marines. Dental Computer-aided design /Computer-assisted manufacturing (CAD/CAM...this time by allowing for rapid scanning, designing , development, and production of dental restorations. Using this technology gives dentists the

  11. The nordic aortic valve intervention (NOTION) trial comparing transcatheter versus surgical valve implantation

    DEFF Research Database (Denmark)

    Thyregod, Hans Gustav; Søndergaard, Lars; Ihlemann, Nikolaj

    2013-01-01

    Degenerative aortic valve (AV) stenosis is the most prevalent heart valve disease in the western world. Surgical aortic valve replacement (SAVR) has until recently been the standard of treatment for patients with severe AV stenosis. Whether transcatheter aortic valve implantation (TAVI) can...

  12. Fluid control valves

    International Nuclear Information System (INIS)

    Rankin, J.

    1980-01-01

    A fluid control valve is described in which it is not necessary to insert a hand or a tool into the housing to remove the valve seat. Such a valve is particularly suitable for the control of radioactive fluids since maintenance by remote control is possible. (UK)

  13. What Is Heart Valve Surgery?

    Science.gov (United States)

    ... working correctly. Most valve replacements involve the aortic Tricuspid valve and mitral valves. The aortic valve separates ... where it shouldn’t. This is called incompetence, insufficiency or regurgitation. • Prolapse — mitral valve flaps don’t ...

  14. What Is Heart Valve Disease?

    Science.gov (United States)

    ... and replacing it with a man-made or biological valve. Biological valves are made from pig, cow, or human ... the valve. Man-made valves last longer than biological valves and usually don’t have to be ...

  15. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  16. Comparative study between CardiaMed valves (freely floating valve leaflets versus St. Jude Medical (fixed valve leaflets in mitral valve replacement surgery

    Directory of Open Access Journals (Sweden)

    Mostafa Ahmed

    2017-09-01

    Conclusions: CardiaMed freely floating leaflet prostheses showed good hemodynamic characteristics. The prosthesis adequately corrects hemodynamics and is safe and no worse than the St. Jude Medical valve in the mitral valve position.

  17. Face-Sealing Butterfly Valve

    Science.gov (United States)

    Tervo, John N.

    1992-01-01

    Valve plate made to translate as well as rotate. Valve opened and closed by turning shaft and lever. Interactions among lever, spring, valve plate, and face seal cause plate to undergo combination of translation and rotation so valve plate clears seal during parts of opening and closing motions.

  18. Experimentally induced cam impingement in the sheep hip.

    Science.gov (United States)

    Siebenrock, Klaus A; Fiechter, Ruth; Tannast, Moritz; Mamisch, Tallal C; von Rechenberg, Brigitte

    2013-04-01

    Sheep hips have a natural non-spherical femoral head similar to a cam-type deformity in human beings. By performing an intertrochanteric varus osteotomy, cam-type femoro-acetabular impingement (FAI) during flexion can be created. We tested the hypotheses that macroscopic lesions of the articular cartilage and an increased Mankin score (MS) can be reproduced by an experimentally induced cam-type FAI in this ovine in vivo model. Furthermore, we hypothesized that the MS increases with longer ambulatory periods. Sixteen sheep underwent unilateral intertrochanteric varus osteotomy of the hip with the non-operated hip as a control. Four sheep were sacrificed after 14, 22, 30, and 38-weeks postoperatively. We evaluated macroscopic chondrolabral alterations, and recorded the MS, based on histochemical staining, for each ambulatory period. A significantly higher prevalence of macroscopic chondrolabral lesions was found in the impingement zone of the operated hips. The MS was significantly higher in the acetabular/femoral cartilage of the operated hips. Furthermore, these scores increased as the length of the ambulatory period increased. Cam-type FAI can be induced in an ovine in vivo model. Localized chondrolabral degeneration of the hip, similar to that seen in humans (Tannast et al., Clin Orthop Relat Res 2008; 466: 273-280; Beck et al., J Bone Joint Surg Br 2005; 87: 1012-1018), can be reproduced. This experimental sheep model can be used to study cam-type FAI. Copyright © 2012 Orthopaedic Research Society.

  19. Optimising the cam profile of an electronic unit pump for a heavy-duty diesel engine

    International Nuclear Information System (INIS)

    Qiu, Tao; Dai, Hefei; Lei, Yan; Cao, Chunlei; Li, Xuchu

    2015-01-01

    For a fuel system with a tangent cam or a constant-velocity cam, the peak injection pressure continues to rise as the injection duration increases, but overly high peak pressures induce mechanical loads and wear, limiting the maximum engine speed and injection quantity. To improve the performance of an EUP (Electronic Unit Pump) fuel system for heavy-duty diesel engines, this work proposes a new pump cam, namely the constant-pressure cam. It helps the EUP run at a higher speed and deliver larger fuel quantities while maintaining a constant peak injection pressure, which improves the power of the heavy-duty diesel engine. A model based on the EUP was built to determine the three constraints for optimising the constant-pressure cam: 1) the pump pressure should equal the nozzle pressure; 2) the cam speed should decrease with the increase in the injection duration; and 3) the cam acceleration gradient should be zero. An EUP system was tested with the tangent cam and the optimised cam under different conditions. The experimental results show that the EUP system with the optimised cam delivers more injection quantity and runs at higher engine speeds while maintaining the same peak pressure as the tangent cam. - Highlights: • We propose a constant-pressure cam to improve the power of heavy-duty diesel engine. • We deduce three constraints for the CP (constant-peak pressure) cam based on a model. • The EUP system with the new cam works well under higher engine speed. • The peak pressure of the constant-pressure cam fuel system maintains high

  20. Transapical JenaValve in a patient with mechanical mitral valve prosthesis.

    LENUS (Irish Health Repository)

    O' Sullivan, Katie E

    2014-01-29

    We report the first case of transcatheter aortic valve replacement implantation using JenaValve™ in a patient with mechanical mitral valve prosthesis. We believe that the design features of this valve may be particularly suited for use in this setting. © 2014 Wiley Periodicals, Inc.

  1. Butterfly valves for seawater

    International Nuclear Information System (INIS)

    Yamanaka, Katsuto

    1991-01-01

    Recently in thermal and nuclear power stations and chemical plants which have become large capacity, large quantity of cooling water is required, and mostly seawater is utilized. In these cooling water systems, considering thermal efficiency and economy, the pipings become complex, and various control functions are demanded. For the purpose, the installation of shut-off valves and control valves for pipings is necessary. The various types of valves have been employed, and in particular, butterfly valves have many merits in their function, size, structure, operation, maintenance, usable period, price and so on. The corrosion behavior of seawater is complicated due to the pollution of seawater, therefore, the environment of the valves used for seawater became severe. The structure and the features of the butterfly valves for seawater, the change of the structure of the butterfly valves for seawater and the checkup of the butterfly valves for seawater are reported. The corrosion of metallic materials is complicatedly different due to the locating condition of plants, the state of pipings and the condition of use. The corrosion countermeasures for butterfly valves must be examined from the synthetic viewpoints. (K.I.)

  2. Supra-annular valve strategy for an early degenerated transcatheter balloon-expandable heart valve.

    Science.gov (United States)

    Kamioka, Norihiko; Caughron, Hope; Corrigan, Frank; Block, Peter; Babaliaros, Vasilis

    2018-01-23

    Currently, there are no recommendations regarding the selection of valve type for a transcatheter heart valve (THV)-in-THV procedure. A supra-annular valve design may be superior in that it results in a larger effective orifice area and may have a lower chance of valve thrombosis after THV-in-THV. In this report, we describe the use of a supra-annular valve strategy for an early degenerated THV. © 2018 Wiley Periodicals, Inc.

  3. Comparative evaluation of RetCam vs. gonioscopy images in congenital glaucoma

    Directory of Open Access Journals (Sweden)

    Raj V Azad

    2014-01-01

    Full Text Available Purpose: To compare clarity, exposure and quality of anterior chamber angle visualization in congenital glaucoma patients, using RetCam and indirect gonioscopy images. Design: Cross-sectional study Participants. Congenital glaucoma patients over age of 5 years. Materials and Methods: A prospective consecutive pilot study was done in congenital glaucoma patients who were older than 5 years. Methods used are indirect gonioscopy and RetCam imaging. Clarity of the image, extent of angle visible and details of angle structures seen were graded for both methods, on digitally recorded images, in each eye, by two masked observers. Outcome Measures: Image clarity, interobserver agreement. Results: 40 eyes of 25 congenital glaucoma patients were studied. RetCam image had excellent clarity in 77.5% of patients versus 47.5% by gonioscopy. The extent of angle seen was similar by both methods. Agreement between RetCam and gonioscopy images regarding details of angle structures was 72.50% by observer 1 and 65.00% by observer 2. Conclusions: There was good agreement between RetCam and indirect gonioscopy images in detecting angle structures of congenital glaucoma patients. However, RetCam provided greater clarity, with better quality, and higher magnification images. RetCam can be a useful alternative to gonioscopy in infants and small children without the need for general anesthesia.

  4. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  5. Evaluation of complementary-alternative medicine (CAM) questionnaire development for Indonesian clinical psychologists: A pilot study.

    Science.gov (United States)

    Liem, Andrian; Newcombe, Peter A; Pohlman, Annie

    2017-08-01

    This study aimed to evaluate questionnaire development to measure the knowledge of Complementary-Alternative Medicine (CAM), attitudes towards CAM, CAM experiences, and CAM educational needs of clinical psychologists in Indonesia. A 26-item questionnaire was developed through an extensive literature search. Data was obtained from provisional psychologists from the Master of Professional Clinical Psychology programs at two established public universities in urban areas of Indonesia. To validate the questionnaire, panel reviews by executive members of the Indonesian Clinical Psychology Association (ICPA), experts in health psychology, and experts in public health and CAM provided their professional judgements. The self-reporting questionnaire consisted of four scales including: knowledge of CAM (6 items), attitudes towards CAM (10 items), CAM experiences (4 items), and CAM educational needs (6 items). All scales, except CAM Experiences, were assessed on a 7-point Likert scale. Sixty provisional psychologists were eligible to complete the questionnaire with a response rate of 73% (N=44). The results showed that the CAM questionnaire was reliable (Cronbach's coefficient alpha range=0.62-0.96; item-total correlation range=0.14-0.92) and demonstrated content validity. Following further psychometric evaluation, the CAM questionnaire may provide the evidence-based information to inform the education and practice of Indonesian clinical psychologists. Copyright © 2017 Elsevier Ltd. All rights reserved.

  6. Modeling valve leakage

    International Nuclear Information System (INIS)

    Bell, S.R.; Rohrscheib, R.

    1994-01-01

    The American Society of Mechanical Engineers (ASME) Code requires individual valve leakage testing for Category A valves. Although the U.S. Nuclear Regulatory Commission (USNRC) has recognized that it is more appropriate to test containment isolation valves in groups, as allowed by 10 CFR 50, Appendix J, a utility seeking relief from these Code requirements must provide technical justification for the relief and establish a conservative alternate acceptance criteria. In order to provide technical justification for group testing of containment isolation valves, Illinois Power developed a calculation (model) for determining the size of a leakage pathway in a valve disc or seat for a given leakage rate. The model was verified experimentally by machining leakage pathways of known size and then measuring the leakage and comparing this value to the calculated value. For the range of values typical of leakage rate testing, the correlation between the experimental values and calculated values was quote good. Based upon these results, Illinois Power established a conservative acceptance criteria for all valves in the inservice testing (IST) program and was granted relief by the USNRC from the individual leakage testing requirements of the ASME Code. This paper presents the results of Illinois Power's work in the area of valve leakage rate testing

  7. Demand for CAM Practice at Hospitals in Japan: A Population Survey in Mie Prefecture

    Directory of Open Access Journals (Sweden)

    Toshihiro Togo

    2011-01-01

    Full Text Available Complementary and alternative medicine (CAM therapies have been provided at hospitals along with conventional medicine in industrialized nations. Previous studies conducted in Japan revealed high proportion of Japanese had experience of using CAM, but failed to discuss how it should be provided. The present study aims to clarify the demand for CAM practice at hospitals in Japan. A questionnaire consisting of 41 questions was mailed to 10 000 adults randomly selected from the electoral roll of Mie prefecture, Japan in January 2007. The questionnaire asked the subjects about demand for CAM practice at hospitals, types of CAM therapy to be provided and associated reasons. Sociodemographic characteristics, perceived health status, experience and purpose of CAM use, and information resource for CAM were also surveyed. Completed answers were collected from 2824 (28.6% respondents. Two thousand and nineteen (71.5% of the respondents demanded CAM practice at hospitals with the most likely reason of “patients can receive treatment under the guidance of a physicians”. The three most popular CAM therapies were Kampo, acupressure/massage/Shiatsu and acupuncture/moxibustion. The demand was positively associated with gender, ages of 40–59 years, annual household incomes of 5–7 million yen, occupation of specialist and technical workers and sales workers and poor health status. Higher demand was observed among those who used both CAM and conventional medical therapies for curative purposes. In conclusion, Japanese show a high demand for CAM practice, hoping to use CAM for curative purposes with monitoring by physicians at hospitals.

  8. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  9. Multiple-port valve

    International Nuclear Information System (INIS)

    Doody, T.J.

    1978-01-01

    A multiple-port valve assembly is designed to direct flow from a primary conduit into any one of a plurality of secondary conduits as well as to direct a reverse flow. The valve includes two mating hemispherical sockets that rotatably receive a spherical valve plug. The valve plug is attached to the primary conduit and includes diverging passageways from that conduit to a plurality of ports. Each of the ports is alignable with one or more of a plurality of secondary conduits fitting into one of the hemispherical sockets. The other hemispherical socket includes a slot for the primary conduit such that the conduit's motion along that slot with rotation of the spherical plug about various axes will position the valve-plug ports in respect to the secondary conduits

  10. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  11. Redo mitral valve surgery

    Directory of Open Access Journals (Sweden)

    Redoy Ranjan

    2018-03-01

    Full Text Available This study is based on the findings of a single surgeon’s practice of mitral valve replacement of 167 patients from April 2005 to June 2017 who developed symptomatic mitral restenosis after closed or open mitral commisurotomy. Both clinical and color doppler echocardiographic data of peri-operative and six months follow-up period were evaluated and compared to assess the early outcome of the redo mitral valve surgery. With male-female ratio of 1: 2.2 and after a duration of 6 to 22 years symptom free interval between the redo procedures, the selected patients with mitral valve restenosis undergone valve replacement with either mechanical valve in 62% cases and also tissue valve in 38% cases. Particular emphasis was given to separate the adhered pericardium from the heart completely to ameliorate base to apex and global contraction of the heart. Besides favorable post-operative clinical outcome, the echocardiographic findings were also encouraging as there was statistically significant increase in the mitral valve area and ejection fraction with significant decrease in the left atrial diameter, pressure gradient across the mitral valve and pulmonary artery systolic pressure. Therefore, in case of inevitable mitral restenosis after closed or open commisurotomy, mitral valve replacement is a promising treatment modality.

  12. Double-disc gate valve

    International Nuclear Information System (INIS)

    Wheatley, S.J.

    1979-01-01

    The invention relates to an improvement in a conventional double-disc gate valve having a vertically movable gate assembly including a wedge, spreaders slidably engaged therewith, a valve disc carried by the spreaders. When the gate assembly is lowered to a selected point in the valve casing, the valve discs are moved transversely outward to close inlet and outlet ports in the casing. The valve includes hold-down means for guiding the disc-and-spreader assemblies as they are moved transversely outward and inward. If such valves are operated at relatively high differential pressures, they sometimes jam during opening. Such jamming has been a problem for many years in gate valves used in gaseous diffusion plants for the separation of uranium isotopes. The invention is based on the finding that the above-mentioned jamming results when the outlet disc tilts about its horizontal axis in a certain way during opening of the valve. In accordance with the invention, tilting of the outlet disc is maintained at a tolerable value by providing the disc with a rigid downwardly extending member and by providing the casing with a stop for limiting inward arcuate movement of the member to a preselected value during opening of the valve

  13. Fracture strength testing of crowns made of CAD/CAM composite resins.

    Science.gov (United States)

    Okada, Ryota; Asakura, Masaki; Ando, Akihiro; Kumano, Hirokazu; Ban, Seiji; Kawai, Tatsushi; Takebe, Jun

    2018-03-28

    The purpose of this study was to ascertain whether computer aided design/computer aided manufacturing (CAD/CAM) composite resin crowns have sufficient strength to withstand the bite force of the molar teeth. The null hypothesis was that the fracture strength of CAD/CAM composite resin crowns is lower than the average maximum bite force of the molar tooth. The crowns, which shape is the right maxillary first molar, were fabricated using four CAD/CAM blanks made of composite resins (Block HC: HC, KZR-CAD HR: HR, KZR-CAD HR2: HR2, Avencia Block: AVE) and one CAD/CAM blank made of lithium disilicate glass-ceramic (IPS e.max CAD: IPS), which was used as a control. Fracture strength of fabricated crowns bonded to metal abutment and biaxial flexural strength of the materials were evaluated. The results of fracture strength test and biaxial flexural strength test showed different tendencies. The fracture strength of CAD/CAM composite resin crowns except HC ranged from 3.3kN to 3.9kN, and was similar to that of IPS (3.3kN). In contrast, biaxial flexural strength of CAD/CAM composite resins ranged from 175MPa to 247MPa, and was significantly lower than that of IPS (360MPa). All CAD/CAM composite resin crowns studied presented about 3-4 times higher fracture strength than the average maximum bite force of the molar tooth (700-900N), which result leads to the conclusion that CAD/CAM composite resin crowns would have sufficient strength to withstand the bite force of the molar teeth. Copyright © 2017 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  14. Reasons for continuing use of Complementary and Alternative Medicine (CAM) in students: a consumer commitment model.

    Science.gov (United States)

    Sirois, Fuschia M; Salamonsen, Anita; Kristoffersen, Agnete E

    2016-02-24

    Research on continued CAM use has been largely atheoretical and has not considered the broader range of psychological and behavioral factors that may be involved. The purpose of this study was to test a new conceptual model of commitment to CAM use that implicates utilitarian (trust in CAM) and symbolic (perceived fit with CAM) in psychological and behavioral dimensions of CAM commitment. A student sample of CAM consumers, (N = 159) completed a survey about their CAM use, CAM-related values, intentions for future CAM use, CAM word-of-mouth behavior, and perceptions of being an ongoing CAM consumer. Analysis revealed that the utilitarian, symbolic, and CAM commitment variables were significantly related, with r's ranging from .54 to .73. A series hierarchical regression analyses controlling for relevant demographic variables found that the utilitarian and symbolic values uniquely accounted for significant and substantial proportion of the variance in each of the three CAM commitment indicators (R(2) from .37 to .57). The findings provide preliminary support for the new model that posits that CAM commitment is a multi-dimensional psychological state with behavioral indicators. Further research with large-scale samples and longitudinal designs is warranted to understand the potential value of the new model.

  15. Intro to Valve Guide Reconditioning. Automotive Mechanics. Valves. Instructor's Guide [and] Student Guide.

    Science.gov (United States)

    Horner, W.

    This instructional package, one in a series of individualized instructional units on tools and techniques for repairing worn valve guides in motor vehicles, provides practical experience for students in working on cylinder heads. Covered in the module are reaming valve guides that are oversized to match a new oversized valve, reaming valve guides…

  16. Bonding Effectiveness of Luting Composites to Different CAD/CAM Materials.

    Science.gov (United States)

    Peumans, Marleen; Valjakova, Emilija Bajraktarova; De Munck, Jan; Mishevska, Cece Bajraktarova; Van Meerbeek, Bart

    To evaluate the influence of different surface treatments of six novel CAD/CAM materials on the bonding effectiveness of two luting composites. Six different CAD/CAM materials were tested: four ceramics - Vita Mark II; IPS Empress CAD and IPS e.max CAD; Celtra Duo - one hybrid ceramic, Vita Enamic, and one composite CAD/CAM block, Lava Ultimate. A total of 60 blocks (10 per material) received various mechanical surface treatments: 1. 600-grit SiC paper; 2. sandblasting with 30-μm Al2O3; 3. tribochemical silica coating (CoJet). Subsequent chemical surface treatments involved either no further treatment (control), HF acid etching (HF), silanization (S, or HF acid etching followed by silanization (HF+S). Two specimens with the same surface treatment were bonded together using two dual-curing luting composites: Clearfil Esthetic Cement (self-etching) or Panavia SA Cement (self-adhesive). After 1 week of water storage, the microtensile bond strength of the sectioned microspecimens was measured and the failure mode was evaluated. The bonding performance of the six CAD/CAM materials was significantly influenced by surface treatment (linear mixed models, p CAD (p = 0.0115), and Lava Ultimate (p CAD/CAM materials: Vita Mark II and IPS Empress CAD: S, HF+S; Celtra Duo: HF, HF+S; IPS e.max CAD: HF+S; Vita Enamic: HF+S, S. For Lava Ultimate, the highest bond strengths were obtained with HF, S, HF+S. Failure analysis showed a relation between bond strength and failure type: more mixed failures were observed with higher bond strengths. Mainly adhesive failures were noticed if no further surface treatment was done. The percentage of adhesive failures was higher for CAD/CAM materials with higher flexural strength (Celtra Duo, IPS e.max CAD, and Lava Ultimate). The bond strength of luting composites to novel CAD/CAM materials is influenced by surface treatment. For each luting composite, an adhesive cementation protocol can be specified in order to obtain the highest bond to the

  17. Effectiveness and efficiency of a CAD/CAM orthodontic bracket system.

    Science.gov (United States)

    Brown, Matthew W; Koroluk, Lorne; Ko, Ching-Chang; Zhang, Kai; Chen, Mengqi; Nguyen, Tung

    2015-12-01

    The first straight-wire appliance was introduced over 40 years ago to increase the consistency and efficiency of orthodontic treatment. More recently, computer-aided design and computer-aided manufacturing (CAD/CAM) technology has been used to create individualized orthodontic appliances. The purpose of this study was to investigate the clinical effectiveness and efficiency of CAD/CAM customized orthodontic appliances compared with direct and indirect bonded stock orthodontic brackets. This retrospective study included 3 treatment groups: group 1 patients were direct bonded with self-ligating appliances, group 2 patients were indirect bonded with self-ligating appliances, and group 3 patients were indirect bonded with CAD/CAM self-ligating appliances. Complete pretreatment and posttreatment records were obtained for all patients. The American Board of Orthodontics (ABO) Discrepancy Index was used to evaluate the pretreatment records, and the posttreatment outcomes were analyzed using the ABO Cast-Radiograph Evaluation. All data collection and analysis were completed by 1 evaluator. There were no statistically significant differences in the ABO Discrepancy Index or the ABO Cast-Radiograph Evaluation among the groups. Treatment times for the 3 groups were significantly different; the CAD/CAM group was the shortest at 13.8 ± 3.4 months, compared with 21.9 ± 5.0 and 16.9 ± 4.1 months for the direct bonded and indirect bonded groups, respectively. The number of treatment appointments for the CAD/CAM group was significantly fewer than for the direct bonded group. The CAD/CAM orthodontic bracket system evaluated in this study was as effective in treatment outcome measures as were standard brackets bonded both directly and indirectly. The CAD/CAM appliance was more efficient in regard to treatment duration, although the decrease in total archwire appointments was minimal. Further investigation is needed to better quantify the clinical benefits of CAD/CAM orthodontic

  18. Guide to prosthetic cardiac valves

    International Nuclear Information System (INIS)

    Morse, D.; Steiner, R.M.; Fernandez, J.

    1985-01-01

    This book contains 10 chapters. Some of the chapter titles are: The development of artificial heart valves: Introduction and historical perspective; The radiology of prosthetic heart valves; The evaluation of patients for prosthetic valve implantation; Pathology of cardiac valve replacement; and Bioengineering of mechanical and biological heart valve substitutes

  19. SenseCam: A new tool for memory rehabilitation?

    Science.gov (United States)

    Dubourg, L; Silva, A R; Fitamen, C; Moulin, C J A; Souchay, C

    2016-12-01

    The emergence of life-logging technologies has led neuropsychologist to focus on understanding how this new technology could help patients with memory disorders. Despite the growing number of studies using life-logging technologies, a theoretical framework supporting its effectiveness is lacking. This review focuses on the use of life-logging in the context of memory rehabilitation, particularly the use of SenseCam, a wearable camera allowing passive image capture. In our opinion, reviewing SenseCam images can be effective for memory rehabilitation only if it provides more than an assessment of prior occurrence in ways that reinstates previous thoughts, feelings and sensory information, thus stimulating recollection. Considering the fact that, in memory impairment, self-initiated processes are impaired, we propose that the environmental support hypothesis can explain the value of SenseCam for memory retrieval. Twenty-five research studies were selected for this review and despite the general acceptance of the value of SenseCam as a memory technique, only a small number of studies focused on recollection. We discuss the usability of this tool to improve episodic memory and in particular, recollection. Copyright © 2016 Elsevier Masson SAS. All rights reserved.

  20. Control of fast non linear systems - application to a turbo charged SI engine with variable valve timing; controle des systemes rapides non lineaires - application au moteur a allumage commande turbocompresse a distribution variable

    Energy Technology Data Exchange (ETDEWEB)

    Colin, G.

    2006-10-15

    Spark ignition engine control has become a major issue for the compliance with emissions legislation while ensuring driving comfort. Engine down-sizing is one of the promising ways to reduce fuel consumption and resulting CO{sub 2} emissions. Combining several existing technologies such as supercharging and variable valve actuation, down-sizing is a typical example of the problems encountered in Spark Ignited (SI) engine control: nonlinear systems with saturation of actuators; numerous major physical phenomena not measurable; limited computing time; control objectives (consumption, pollution, performance) often competing. A methodology of modelling and model-based control (internal model and predictive control) for these systems is also proposed and applied to the air path of the down-sized engine. Models, physicals and generics, are built to estimate in-cylinder air mass, residual burned gases mass and air scavenged mass from the intake to the exhaust. The complete and generic engine torque control architecture for the turbo-charged SI engine with variable cam-shaft timing was tested in simulation and experimentally (on engine and vehicle). These tests show that new possibilities are offered in order to decrease pollutant emissions and optimize engine efficiency. (author)

  1. CAM and stack air sampler design guide

    International Nuclear Information System (INIS)

    Phillips, T.D.

    1994-01-01

    About 128 air samplers and CAMs presently in service to detect and document potential radioactive release from 'H' and 'F' area tank farm ventilation stacks are scheduled for replacement and/or upgrade by Projects S-5764, S-2081, S-3603, and S-4516. The seven CAMs scheduled to be upgraded by Project S-4516 during 1995 are expected to provide valuable experience for the three remaining projects. The attached document provides design guidance for the standardized High Level Waste air sampling system

  2. Verification of Kaplan turbine cam curves realization accuracy at power plant

    Directory of Open Access Journals (Sweden)

    Džepčeski Dane

    2016-01-01

    Full Text Available Sustainability of approximately constant value of Kaplan turbine efficiency, for relatively large net head changes, is a result of turbine runner variable geometry. Dependence of runner blades position change on guide vane opening represents the turbine cam curve. The cam curve realization accuracy is of great importance for the efficient and proper exploitation of turbines and consequently complete units. Due to the reasons mentioned above, special attention has been given to the tests designed for cam curves verification. The goal of this paper is to provide the description of the methodology and the results of the tests performed in the process of Kaplan turbine cam curves verification.

  3. CAM use in pediatric neurology: an exploration of concurrent use with conventional medicine.

    Science.gov (United States)

    Galicia-Connolly, Elaine; Adams, Denise; Bateman, Justin; Dagenais, Simon; Clifford, Tammy; Baydala, Lola; King, W James; Vohra, Sunita

    2014-01-01

    Previous studies have found that up to 60% of children with neurologic conditions have tried complementary and alternative medicine (CAM). To assess the use of CAM among patients presenting to neurology clinics at two academic centers in Canada. A survey instrument was developed to inquire about use of CAM products and therapies, including reasons for use, perceived helpfulness, and concurrent use with conventional medicine, and administered to patients or their parents/guardians at the Stollery Children's Hospital in Edmonton and the Children's Hospital of Eastern Ontario (CHEO) in Ottawa. Overall CAM use at the Stollery was 78%, compared to 48% at CHEO. The most common CAM products used were multi-vitamins (84%), vitamin C (37%), homeopathic remedies (24%), and fish oil/omega 3 s (22%). The most common CAM practices used were massage (47%), chiropractic (37%), faith healing (18%), aromatherapy (16%), homeopathy (16%), and relaxation (16%). Many patients used CAM products at the same time as conventional medicine but just over half (57%) discussed this concurrent use with their physician. CAM use is common in pediatric neurology patients and most respondents felt that it was helpful, with few or no harms associated. However, this use is often undisclosed, increasing possibility of interactions with conventional drugs. We urge clinicians to inquire about CAM use during routine history taking at every patient visit. Parents would clearly like more information about CAM from their specialty clinics; such information would be easier to share if more primary data were available about the safety and effectiveness of commonly used therapies.

  4. A planar PDMS micropump using in-contact minimized-leakage check valves

    International Nuclear Information System (INIS)

    Ni, Junhui; Li, Beizhi; Huang, Fengliang; Wang, Bin; Lin, Qiao

    2010-01-01

    We present a micropump with a simple planar design featuring compliant in-contact check valves in a single layer, which allows for a simple structure and easy system integration. The micropump, based on poly(dimethylsiloxane) (PDMS), primarily consists of a pneumatically driven thin membrane, a pump chamber, and two in-plane check valves. The pair of check valves is based on an in-contact flap–stopper configuration and is able to minimize leakage flow, greatly enhancing the reliability and performance of the micropump. Systematic experimental characterization of the micropump has been performed in terms of the frequency response of the pumping flow rate with respect to factors including device geometry (e.g. chamber height) and operating parameters (e.g. pneumatic driving pressure and backpressure). The results demonstrate that this micropump is capable of reliably generating a maximum flow rate of 41 µL min −1 and operating against a high backpressure of up to 25 kPa. In addition, a lumped-parameter theoretical model for the planar micropump is also developed for accurate analysis of the device behavior. These results demonstrate the capability of this micropump for diverse applications in lab-on-a-chip systems.

  5. Prevalence of cam hip shape morphology: a systematic review.

    Science.gov (United States)

    Dickenson, E; Wall, P D H; Robinson, B; Fernandez, M; Parsons, H; Buchbinder, R; Griffin, D R

    2016-06-01

    Cam hip shape morphology is a recognised cause of femoroacetabular impingement (FAI) and is associated with hip osteoarthritis. Our aim was to systematically review the available epidemiological evidence assessing the prevalence of cam hip shape morphology in the general population and any studied subgroups including subjects with and without hip pain. All studies that reported the prevalence of cam morphology, measured by alpha angles, in subjects aged 18 and over, irrespective of study population or presence of hip symptoms were considered for inclusion. We searched AMED, MEDLINE, EMBASE, CINAHL and CENTRAL in October 2015. Two authors independently identified eligible studies and assessed risk of bias. We planned to pool data of studies considered clinically homogenous. Thirty studies met inclusion criteria. None of the included studies were truly population-based: three included non-representative subgroups of the general population, 19 included differing clinical populations, while eight included professional athletes. All studies were judged to be at high risk of bias. Due to substantial clinical heterogeneity meta analysis was not possible. Across all studies, the prevalence estimates of cam morphology ranged from 5 to 75% of participants affected. We were unable to demonstrate a higher prevalence in selected subgroups such as athletes or those with hip pain. There is currently insufficient high quality data to determine the true prevalence of cam morphology in the general population or selected subgroups. Well-designed population-based epidemiological studies that use homogenous case definitions are required to determine the prevalence of cam morphology and its relationship to hip pain. Copyright © 2016 Osteoarthritis Research Society International. Published by Elsevier Ltd. All rights reserved.

  6. Trans-apical aortic valve implantation in a patient with stentless valve degeneration.

    Science.gov (United States)

    Kapetanakis, Emmanouil I; MacCarthy, Philip; Monaghan, Mark; Wendler, Olaf

    2011-06-01

    Trans-apical valve-in-valve trans-catheter aortic valve implantation (TAVI) has successfully been performed in selected, high-risk patients, who suffered prosthetic degeneration after aortic valve replacement using stented xenografts. We report the case of a 79-year-old male patient who underwent one of the first successful TAVIs in a failing stentless bioprosthesis. Copyright © 2010 European Association for Cardio-Thoracic Surgery. Published by Elsevier B.V. All rights reserved.

  7. CAM therapies among primary care patients using opioid therapy for chronic pain

    Directory of Open Access Journals (Sweden)

    Mundt Marlon P

    2007-05-01

    Full Text Available Abstract Background Complementary and alternative medicine (CAM is an increasingly common therapy used to treat chronic pain syndromes. However; there is limited information on the utilization and efficacy of CAM therapy in primary care patients receiving long-term opioid therapy. Method A survey of CAM therapy was conducted with a systematic sample of 908 primary care patients receiving opioids as a primary treatment method for chronic pain. Subjects completed a questionnaire designed to assess utilization, efficacy and costs of CAM therapies in this population. Results Patients were treated for a variety of pain problems including low back pain (38.4%, headaches (9.9%, and knee pain (6.5%; the average duration of pain was 16 years. The median morphine equivalent opioid dose was 41 mg/day, and the mean dose was 92 mg/day. Forty-four percent of the sample reported CAM therapy use in the past 12 months. Therapies utilized included massage therapy (27.3%, n = 248, chiropractic treatment (17.8%, n = 162, acupuncture (7.6%, n = 69, yoga (6.1%, n = 55, herbs and supplements (6.8%, n = 62, and prolotherapy (5.9%, n = 54. CAM utilization was significantly related to age female gender, pain severity income pain diagnosis of neck and upper back pain, and illicit drug use. Medical insurance covered chiropractic treatment (81.8% and prolotherapy (87.7%, whereas patients primarily paid for other CAM therapies. Over half the sample reported that one or more of the CAM therapies were helpful. Conclusion This study suggests CAM therapy is widely used by patients receiving opioids for chronic pain. Whether opioids can be reduced by introducing such therapies remains to be studied.

  8. CAM therapies among primary care patients using opioid therapy for chronic pain.

    Science.gov (United States)

    Fleming, Sara; Rabago, David P; Mundt, Marlon P; Fleming, Michael F

    2007-05-16

    Complementary and alternative medicine (CAM) is an increasingly common therapy used to treat chronic pain syndromes. However; there is limited information on the utilization and efficacy of CAM therapy in primary care patients receiving long-term opioid therapy. A survey of CAM therapy was conducted with a systematic sample of 908 primary care patients receiving opioids as a primary treatment method for chronic pain. Subjects completed a questionnaire designed to assess utilization, efficacy and costs of CAM therapies in this population. Patients were treated for a variety of pain problems including low back pain (38.4%), headaches (9.9%), and knee pain (6.5%); the average duration of pain was 16 years. The median morphine equivalent opioid dose was 41 mg/day, and the mean dose was 92 mg/day. Forty-four percent of the sample reported CAM therapy use in the past 12 months. Therapies utilized included massage therapy (27.3%, n = 248), chiropractic treatment (17.8%, n = 162), acupuncture (7.6%, n = 69), yoga (6.1%, n = 55), herbs and supplements (6.8%, n = 62), and prolotherapy (5.9%, n = 54). CAM utilization was significantly related to age female gender, pain severity income pain diagnosis of neck and upper back pain, and illicit drug use. Medical insurance covered chiropractic treatment (81.8%) and prolotherapy (87.7%), whereas patients primarily paid for other CAM therapies. Over half the sample reported that one or more of the CAM therapies were helpful. This study suggests CAM therapy is widely used by patients receiving opioids for chronic pain. Whether opioids can be reduced by introducing such therapies remains to be studied.

  9. Early clinical outcome of aortic transcatheter valve-in-valve implantation in the Nordic countries

    DEFF Research Database (Denmark)

    Ihlberg, Leo; Nissen, Henrik Hoffmann; Nielsen, Niels Erik

    2013-01-01

    Transcatheter valve-in-valve implantation has emerged as an option, in addition to reoperative surgical aortic valve replacement, to treat failed biologic heart valve substitutes. However, the clinical experience with this approach is still limited. We report the comprehensive experience...

  10. Nuclear valves latest development

    International Nuclear Information System (INIS)

    Isaac, F.; Monier, M.

    1993-01-01

    In the frame of Nuclear Power Plant upgrade (Emergency Power Supply and Emergency Core Cooling), Westinghouse had to face a new valve design philosophy specially for motor operated valves. The valves have to been designed to resist any operating conditions, postulated accident or loss of control. The requirements for motor operated valves are listed and the selected model and related upgrading explained. As part of plant upgrade and valves replacement, Westinghouse has sponsored alternative hardfacing research programme. Two types of materials have been investigated: nickel base alloys and iron base alloys. Programme requirements and test results are given. A new globe valve model (On-Off or regulating) is described developed by Alsthom Velan permitting the seat replacement in less than 10 min. (Z.S.) 2 figs

  11. Magnetic Check Valve

    Science.gov (United States)

    Morris, Brian G.; Bozeman, Richard J., Jr.

    1994-01-01

    Poppet in proposed check valve restored to closed condition by magnetic attraction instead of spring force. Oscillations suppressed, with consequent reduction of wear. Stationary magnetic disk mounted just upstream of poppet, also containing magnet. Valve body nonmagnetic. Forward pressure or flow would push poppet away from stationary magnetic disk so fluid flows easily around poppet. Stop in valve body prevents poppet from being swept away. When flow stopped or started to reverse, magnetic attraction draws poppet back to disk. Poppet then engages floating O-ring, thereby closing valve and preventing reverse flow. Floating O-ring facilitates sealing at low loads.

  12. Analysis of Poiseuille Flow Property in Two-Dimensional Mi-cro Channels of Microfluidic Pneumatic Micro-Valve

    Science.gov (United States)

    Yang, Shaohua; Long, Wei; Chen, Yajun

    2018-03-01

    In this paper, the control mechanism and mathematical description of the microfluidic flow in the microfluidic process of the PDMS membrane type pneumatic micro-valve were studied. The velocity and pressure variation law of the velocity field inside micro valve was analyzed by numerical simulation method. The influence of the two kinds of inlet drive modes on the working effect and the pressure flow characteristics of the pneumatic micro-valve was studied. The structure of the elastic solid valve diaphragm under the dual action of the airway and the liquid channel was analyzed. Deformation and stress distribution. The results show that the gas flow in the gas flow channel under the diaphragm by the vacuum part of the role of the formation of a suction gas vortex, pressure-driven mode was easier under the diaphragm to produce a strong gas vortex, resulting in internal and external pressure to promote diaphragm cut-off liquid channel; In the pressure pneumatic mode, the stress at both ends of the diaphragm was smaller, the membrane was not easy to tear failure.

  13. Effects of valve timing, valve lift and exhaust backpressure on performance and gas exchanging of a two-stroke GDI engine with overhead valves

    International Nuclear Information System (INIS)

    Dalla Nora, Macklini; Lanzanova, Thompson Diórdinis Metzka; Zhao, Hua

    2016-01-01

    Highlights: • Two-stroke operation was achieved in a four-valve direct injection gasoline engine. • Shorter valve opening durations improved torque at lower engine speeds. • The longer the valve opening duration, the lower was the air trapping efficiency. • Higher exhaust backpressure and lower valve lift reduced the compressor work. - Abstract: The current demand for fuel efficient and lightweight powertrains, particularly for application in downsized and hybrid electric vehicles, has renewed the interest in two-stroke engines. In this framework, an overhead four-valve spark-ignition gasoline engine was modified to run in the two-stroke cycle. The scavenging process took place during a long valve overlap period around bottom dead centre at each crankshaft revolution. Boosted intake air was externally supplied at a constant pressure and gasoline was directly injected into the cylinder after valve closure. Intake and exhaust valve timings and lifts were independently varied through an electrohydraulic valve train, so their effects on engine performance and gas exchanging were investigated at 800 rpm and 2000 rpm. Different exhaust backpressures were also evaluated by means of exhaust throttling. Air trapping efficiency, charging efficiency and scavenge ratio were calculated based on air and fuel flow rates, and exhaust oxygen concentration at fuel rich conditions. The results indicated that longer intake and exhaust valve opening durations increased the charge purity and hence torque at higher engine speeds. At lower speeds, although, shorter valve opening durations increased air trapping efficiency and reduced the estimated supercharger power consumption due to lower air short-circuiting. A strong correlation was found between torque and charging efficiency, while air trapping efficiency was more associated to exhaust valve opening duration. The application of exhaust backpressure, as well as lower intake/exhaust valve lifts, made it possible to increase

  14. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis

    Directory of Open Access Journals (Sweden)

    Rajesh Janardhanan

    2016-05-01

    Full Text Available In intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Learning objectives: • Early recognition of a mitral valve aneurysm (MVA is important because it may rupture and produce catastrophic mitral regurgitation (MR in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR. • Real-time 3D-transesophageal echocardiography (RT-3DTEE is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA.

  15. Anterior mitral valve aneurysm: a rare sequelae of aortic valve endocarditis.

    Science.gov (United States)

    Janardhanan, Rajesh; Kamal, Muhammad Umar; Riaz, Irbaz Bin; Smith, M Cristy

    2016-03-01

    SummaryIn intravenous drug abusers, infective endocarditis usually involves right-sided valves, with Staphylococcus aureus being the most common etiologic agent. We present a patient who is an intravenous drug abuser with left-sided (aortic valve) endocarditis caused by Enterococcus faecalis who subsequently developed an anterior mitral valve aneurysm, which is an exceedingly rare complication. A systematic literature search was conducted which identified only five reported cases in the literature of mitral valve aneurysmal rupture in the setting of E. faecalis endocarditis. Real-time 3D-transesophageal echocardiography was critical in making an accurate diagnosis leading to timely intervention. Early recognition of a mitral valve aneurysm (MVA) is important because it may rupture and produce catastrophic mitral regurgitation (MR) in an already seriously ill patient requiring emergency surgery, or it may be overlooked at the time of aortic valve replacement (AVR).Real-time 3D-transesophageal echocardiography (RT-3DTEE) is much more advanced and accurate than transthoracic echocardiography for the diagnosis and management of MVA. © 2016 The authors.

  16. Transcatheter Aortic Valve Replacement for Degenerative Bioprosthetic Surgical Valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John; Brecker, Stephen

    2012-01-01

    Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry....

  17. A Prospective, Multicenter Study of Complementary/Alternative Medicine (CAM) Utilization During Definitive Radiation for Breast Cancer

    International Nuclear Information System (INIS)

    Moran, Meena S.; Ma Shuangge; Jagsi, Reshma; Yang, Tzu-I Jonathan; Higgins, Susan A.; Weidhaas, Joanne B.; Wilson, Lynn D.; Lloyd, Shane; Peschel, Richard; Gaudreau, Bryant; Rockwell, Sara

    2013-01-01

    Purpose: Although complementary and alternative medicine (CAM) utilization in breast cancer patients is reported to be high, there are few data on CAM practices in breast patients specifically during radiation. This prospective, multi-institutional study was conducted to define CAM utilization in breast cancer during definitive radiation. Materials/Methods: A validated CAM instrument with a self-skin assessment was administered to 360 Stage 0-III breast cancer patients from 5 centers during the last week of radiation. All data were analyzed to detect significant differences between users/nonusers. Results: CAM usage was reported in 54% of the study cohort (n=194/360). Of CAM users, 71% reported activity-based CAM (eg, Reiki, meditation), 26% topical CAM, and 45% oral CAM. Only 16% received advice/counseling from naturopathic/homeopathic/medical professionals before initiating CAM. CAM use significantly correlated with higher education level (P<.001), inversely correlated with concomitant hormone/radiation therapy use (P=.010), with a trend toward greater use in younger patients (P=.066). On multivariate analysis, level of education (OR: 6.821, 95% CI: 2.307-20.168, P<.001) and hormones/radiation therapy (OR: 0.573, 95% CI: 0.347-0.949, P=.031) independently predicted for CAM use. Significantly lower skin toxicity scores were reported in CAM users vs nonusers, respectively (mild: 34% vs 25%, severe: 17% vs 29%, P=.017). Conclusion: This is the first prospective study to assess CAM practices in breast patients during radiation, with definition of these practices as the first step for future investigation of CAM/radiation interactions. These results should alert radiation oncologists that a large percentage of breast cancer patients use CAM during radiation without disclosure or consideration for potential interactions, and should encourage increased awareness, communication, and documentation of CAM practices in patients undergoing radiation treatment for breast

  18. AFSC/FMA/CAMS Data Objects

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The CAMS system consists of a set of tables and packages that provide authentication services to all other North Pacific Groundfish and Halibut Observing Program...

  19. Electromagnetic driving units for complex microrobotic systems

    Science.gov (United States)

    Michel, Frank; Ehrfeld, Wolfgang; Berg, Udo; Degen, Reinhard; Schmitz, Felix

    1998-10-01

    Electromagnetic actuators play an important role in macroscopic robotic systems. In combination with motion transformers, like reducing gear units, angular gears or spindle-screw drives, electromagnetic motors in large product lines ensure the rotational or linear motion of robot driving units and grippers while electromagnets drive valves or part conveyors. In this paper micro actuators and miniaturized motion transformers are introduced which allow a similar development in microrobotics. An electromagnetic motor and a planetary gear box, both with a diameter of 1.9 mm, are already commercially available from the cooperation partner of IMM, the company Dr. Fritz Faulhaber GmbH in Schonaich, Germany. In addition, a motor with a diameter of 2.4 mm is in development. The motors successfully drive an angular gear and a belt drive. A linear stage with a motion range of 7 mm and an overall size as small as 5 X 3.5 X 24 mm3 has been realized involving the motor, a stationary spur gear with zero backlash and a spindle-screw drive. By the use of these commercially available elements complex microrobots can be built up cost-efficiently and rapidly. Furthermore, a batch process has been developed to produce the coils of micro actuator arrays using lithographic techniques with SU-8 resin. In applying these components, the modular construction of complex microrobotic systems becomes feasible.

  20. Ceramic dental biomaterials and CAD/CAM technology: state of the art.

    Science.gov (United States)

    Li, Raymond Wai Kim; Chow, Tak Wah; Matinlinna, Jukka Pekka

    2014-10-01

    Ceramics are widely used as indirect restorative materials in dentistry because of their high biocompatibility and pleasing aesthetics. The objective is to review the state of the arts of CAD/CAM all-ceramic biomaterials. CAD/CAM all-ceramic biomaterials are highlighted and a subsequent literature search was conducted for the relevant subjects using PubMed followed by manual search. Developments in CAD/CAM technology have catalyzed researches in all-ceramic biomaterials and their applications. Feldspathic glass ceramic and glass infiltrated ceramic can be fabricated by traditional laboratory methods or CAD/CAM. The advent of polycrystalline ceramics is a direct result of CAD/CAM technology without which the fabrication would not have been possible. The clinical uses of these ceramics have met with variable clinical success. Multiple options are now available to the clinicians for the fabrication of aesthetic all ceramic restorations. Copyright © 2014 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  1. Transcatheter aortic valve replacement

    Science.gov (United States)

    ... gov/ency/article/007684.htm Transcatheter aortic valve replacement To use the sharing features on this page, please enable JavaScript. Transcatheter aortic valve replacement (TAVR) is surgery to replace the aortic valve. ...

  2. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  3. CAD/CAM: improved design quality, increased productivity

    Energy Technology Data Exchange (ETDEWEB)

    Evans, D. E.; England, J.

    1980-01-01

    Maintaining productivity levels while assuring the quality of engineering products grows increasingly more difficult and costly for industries such as the energy industry which are heavily committed to product design. The man/machine interface made possible through the development of computer-aided design/computer-aided manufacturing (CAD/CAM) technology can be applied to the design process as a tool for increased control to assure the quality of the final engineering product. The quality-control aspects of CAD/CAM technology are addressed in this presentation.

  4. The prognosis of infective endocarditis treated with biological valves versus mechanical valves: A meta-analysis.

    Science.gov (United States)

    Tao, Ende; Wan, Li; Wang, WenJun; Luo, YunLong; Zeng, JinFu; Wu, Xia

    2017-01-01

    Surgery remains the primary form of treatment for infective endocarditis (IE). However, it is not clear what type of prosthetic valve provides a better prognosis. We conducted a meta-analysis to compare the prognosis of infective endocarditis treated with biological valves to cases treated with mechanical valves. Pubmed, Embase and Cochrane databases were searched from January 1960 to November 2016.Randomized controlled trials, retrospective cohorts and prospective studies comparing outcomes between biological valve and mechanical valve management for infective endocarditis were analyzed. The Newcastle-Ottawa Scale(NOS) was used to evaluate the quality of the literature and extracted data, and Stata 12.0 software was used for the meta-analysis. A total of 11 publications were included; 10,754 cases were selected, involving 6776 cases of biological valves and 3,978 cases of mechanical valves. The all-cause mortality risk of the biological valve group was higher than that of the mechanical valve group (HR = 1.22, 95% CI 1.03 to 1.44, P = 0.023), as was early mortality (RR = 1.21, 95% CI 1.02 to 1.43, P = 0.033). The recurrence of endocarditis (HR = 1.75, 95% CI 1.26 to 2.42, P = 0.001), as well as the risk of reoperation (HR = 1.79, 95% CI 1.15 to 2.80, P = 0.010) were more likely to occur in the biological valve group. The incidence of postoperative embolism was less in the biological valve group than in the mechanical valve group, but this difference was not statistically significant (RR = 0.90, 95% CI 0.76 to 1.07, P = 0.245). For patients with prosthetic valve endocarditis (PVE), there was no significant difference in survival rates between the biological valve group and the mechanical valve group (HR = 0.91, 95% CI 0.68 to 1.21, P = 0.520). The results of our meta-analysis suggest that mechanical valves can provide a significantly better prognosis in patients with infective endocarditis. There were significant differences in the clinical features of patients

  5. Comparative study of Butterfly valves

    International Nuclear Information System (INIS)

    Galmes Belmonte, F.B.

    1998-01-01

    This work tries to justify the hydrodynamic butterfly valves performance, using the EPRI tests, results carried out in laboratory and in situ. This justification will be possible if: - The valves to study are similar - Their performance is calculated using EPRI's methodology Looking for this objective, the elements of the present work are: 1. Brief EPRI butterfly valve description it wild provide the factors which are necessary to define the butterfly valves similarity. 2. EPRI tests description and range of validation against test data definition. 3. Description of the spanish butterfly analyzed valves, and comparison with the EPRI performance results, to prove that this valves are similar to the EPRI test valves. In this way, it will not be necessary to carry out particular dynamic tests on the spanish valves to describe their hydrodynamic performance. (Author)

  6. Fluid mechanics of heart valves.

    Science.gov (United States)

    Yoganathan, Ajit P; He, Zhaoming; Casey Jones, S

    2004-01-01

    Valvular heart disease is a life-threatening disease that afflicts millions of people worldwide and leads to approximately 250,000 valve repairs and/or replacements each year. Malfunction of a native valve impairs its efficient fluid mechanic/hemodynamic performance. Artificial heart valves have been used since 1960 to replace diseased native valves and have saved millions of lives. Unfortunately, despite four decades of use, these devices are less than ideal and lead to many complications. Many of these complications/problems are directly related to the fluid mechanics associated with the various mechanical and bioprosthetic valve designs. This review focuses on the state-of-the-art experimental and computational fluid mechanics of native and prosthetic heart valves in current clinical use. The fluid dynamic performance characteristics of caged-ball, tilting-disc, bileaflet mechanical valves and porcine and pericardial stented and nonstented bioprostheic valves are reviewed. Other issues related to heart valve performance, such as biomaterials, solid mechanics, tissue mechanics, and durability, are not addressed in this review.

  7. Intelligent Flow Control Valve

    Science.gov (United States)

    Kelley, Anthony R (Inventor)

    2015-01-01

    The present invention is an intelligent flow control valve which may be inserted into the flow coming out of a pipe and activated to provide a method to stop, measure, and meter flow coming from the open or possibly broken pipe. The intelligent flow control valve may be used to stop the flow while repairs are made. Once repairs have been made, the valve may be removed or used as a control valve to meter the amount of flow from inside the pipe. With the addition of instrumentation, the valve may also be used as a variable area flow meter and flow controller programmed based upon flowing conditions. With robotic additions, the valve may be configured to crawl into a desired pipe location, anchor itself, and activate flow control or metering remotely.

  8. Rotary Valve FY 2016 Highlights

    Energy Technology Data Exchange (ETDEWEB)

    Fitsos, P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-12-07

    The fiscal year started with the Rotary Valve (RV) being reassembled after having crashed in June of 2015. The crash occurred when the RV inner surface contacted the housing. The cause of the crash was never confirmed. No particles were found in the 2.5 thousandths of an inch gap and the filters the helium gas passed through were all clean. There were marks on the bearings that looked like electrostatic discharge as shown below in Figure 1. These marks hadn’t been seen before and there were similar discharge marks on some of the ball bearings. Examples of this were found in a literature search of bearing failures. This leads to a possible cause due to this arcing affecting the rotational accuracy of the bearings driving the RV into the housing.

  9. Experience with valves for PHWR reactors

    International Nuclear Information System (INIS)

    Narayan, K.; Mhetre, S.G.

    1977-01-01

    Material specifications and inspection and testing requirements of the valves meant for use in nuclear reactors are mentioned. In the heavy water systems (both primary and moderator) of a PHWR type reactor, the valves used are gate valves, globe valves, diaphragm valves, butterfly valves, check valves and relief valves. Their locations and functions they perform in the Rajasthan Atomic Power Station Unit-1 are described. Experience with them is given. The major problems encountered with them have been : (1) leakage from the stem seals and body bonnet joint, (2) leakage due to failure of diaphragm and/or washout of the packing and (3) malfunctioning. Measures taken to solve these are discussed. Finally a mention has been made of improved versions of valves, namely, metal diaphragm valve and inverted relief valve. (M.G.B.)

  10. Leaving Moderate Tricuspid Valve Regurgitation Alone at the Time of Pulmonary Valve Replacement: A Worthwhile Approach.

    Science.gov (United States)

    Kogon, Brian; Mori, Makoto; Alsoufi, Bahaaldin; Kanter, Kirk; Oster, Matt

    2015-06-01

    Pulmonary valve disruption in patients with tetralogy of Fallot and congenital pulmonary stenosis often results in pulmonary insufficiency, right ventricular dilation, and tricuspid valve regurgitation. Management of functional tricuspid regurgitation at the time of subsequent pulmonary valve replacement remains controversial. Our aims were to (1) analyze tricuspid valve function after pulmonary valve replacement through midterm follow-up and (2) determine the benefits, if any, of concomitant tricuspid annuloplasty. Thirty-five patients with tetralogy of Fallot or congenital pulmonary stenosis were analyzed. All patients had been palliated in childhood by disrupting the pulmonary valve, and all patients had at least moderate tricuspid valve regurgitation at the time of subsequent pulmonary valve replacement. Preoperative and serial postoperative echocardiograms were analyzed. Pulmonary and tricuspid regurgitation, along with right ventricular dilation and dysfunction were scored as 0 (none), 1 (mild), 2 (moderate), and 3 (severe). Right ventricular volume and area were also calculated. Comparisons were made between patients who underwent pulmonary valve replacement alone and those who underwent concomitant tricuspid valve annuloplasty. At 1 month after pulmonary valve replacement, there were significant reductions in pulmonary valve regurgitation (mean 3 vs 0.39, p tricuspid valve regurgitation (mean 2.33 vs 1.3, p tricuspid regurgitation 1 month postoperatively between patients who underwent concomitant tricuspid annuloplasty and those who underwent pulmonary valve replacement alone (mean 1.31 vs 1.29, p = 0.81). However, at latest follow-up (mean 7.0 ± 2.8 years), the degree of tricuspid regurgitation was significantly higher in the concomitant annuloplasty group (mean 1.87 vs 1.12, p = 0.005). In patients with at least moderate tricuspid valve regurgitation, significant improvement in tricuspid valve function and right ventricular size occurs in the first

  11. Understanding dental CAD/CAM for restorations--accuracy from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, Laurent; Lebon, Nicolas; Mawussi, Bernardin; Fron-Chabouis, Hélène; Duret, Francois; Attal, Jean-Pierre

    2015-01-01

    As is the case in the field of medicine, as well as in most areas of daily life, digital technology is increasingly being introduced into dental practice. Computer-aided design/ computer-aided manufacturing (CAD/CAM) solutions are available not only for chairside practice but also for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental practice can be considered as the handling of devices and software processing for the almost automatic design and creation of dental restorations. However, dentists who want to use dental CAD/CAM systems often do not have enough information to understand the variations offered by such technology practice. Knowledge of the random and systematic errors in accuracy with CAD/CAM systems can help to achieve successful restorations with this technology, and help with the purchasing of a CAD/CAM system that meets the clinical needs of restoration. This article provides a mechanical engineering viewpoint of the accuracy of CAD/ CAM systems, to help dentists understand the impact of this technology on restoration accuracy.

  12. The use of CAM and conventional treatments among primary care consulters with chronic musculoskeletal pain.

    Science.gov (United States)

    Artus, Majid; Croft, Peter; Lewis, Martyn

    2007-05-04

    Chronic musculoskeletal pain is the single most cited reason for use of complementary and alternative medicine (CAM). Primary care is the most frequent conventional medical service used by patients with pain in the UK. We are unaware, however, of a direct evidence of the extent of CAM use by primary care patients, and how successful they perceive it to be. To determine CAM use among patients with chronic musculoskeletal pain who have consulted about their pain in primary care. Face-to-face interview-based survey. Three general practices in North Staffordshire. Respondents to a population pain survey who had reported having musculoskeletal pain in the survey and who had consulted about their pain in primary care in the previous 12 months as well as consenting to further research and agreeing to an interview. Information was gathered about their pain and the use of all treatments for pain, including CAM, in the previous year. 138 interviews were completed. 116 participants (84%) had used at least one CAM treatment for pain in the previous year. 65% were current users of CAM. The ratio of over-the-counter CAM use to care from a CAM provider was 3:2. 111 participants (80%) had used conventional treatment. 95 (69%) were using a combination of CAM and conventional treatment. Glucosamine and fish oil were the most commonly used CAM treatments (38%, 35% respectively). Most CAM treatments were scored on average as being helpful, and users indicated that they intended to use again 87% of the CAM treatments they had already used. We provide direct evidence that most primary care consulters with chronic musculoskeletal pain have used CAM in the previous year, usually in combination with conventional treatments. The high prevalence and wide range of users experiences of benefit and harm from CAM strengthen the argument for more research into this type of medicine to quantify benefit and assess safety. The observation that most users of conventional medicine also used CAM

  13. Shared origins of a key enzyme during the evolution of C4 and CAM metabolism

    Science.gov (United States)

    Christin, Pascal-Antoine; Arakaki, Monica; Osborne, Colin P.; Bräutigam, Andrea; Sage, Rowan F.; Hibberd, Julian M.; Kelly, Steven; Covshoff, Sarah; Wong, Gane Ka-Shu; Hancock, Lillian; Edwards, Erika J.

    2014-01-01

    CAM and C4 photosynthesis are two key plant adaptations that have evolved independently multiple times, and are especially prevalent in particular groups of plants, including the Caryophyllales. We investigate the origin of photosynthetic PEPC, a key enzyme of both the CAM and C4 pathways. We combine phylogenetic analyses of genes encoding PEPC with analyses of RNA sequence data of Portulaca, the only plants known to perform both CAM and C4 photosynthesis. Three distinct gene lineages encoding PEPC exist in eudicots (namely ppc-1E1, ppc-1E2 and ppc-2), one of which (ppc-1E1) was recurrently recruited for use in both CAM and C4 photosynthesis within the Caryophyllales. This gene is present in multiple copies in the cacti and relatives, including Portulaca. The PEPC involved in the CAM and C4 cycles of Portulaca are encoded by closely related yet distinct genes. The CAM-specific gene is similar to genes from related CAM taxa, suggesting that CAM has evolved before C4 in these species. The similar origin of PEPC and other genes involved in the CAM and C4 cycles highlights the shared early steps of evolutionary trajectories towards CAM and C4, which probably diverged irreversibly only during the optimization of CAM and C4 phenotypes. PMID:24638902

  14. The Double-Orifice Valve Technique to Treat Tricuspid Valve Incompetence.

    Science.gov (United States)

    Hetzer, Roland; Javier, Mariano; Delmo Walter, Eva Maria

    2016-01-01

    A straightforward tricuspid valve (TV) repair technique was used to treat either moderate or severe functional (normal valve with dilated annulus) or for primary/organic (Ebstein's anomaly, leaflet retraction/tethering and chordal malposition/tethering, with annular dilatation) TV incompetence, and its long-term outcome assessed. A double-orifice valve technique was employed in 91 patients (mean age 52.6 ± 23.2 years; median age 56 years; range: 0.6-82 years) with severe tricuspid regurgitation. Among the patients, three had post-transplant iatrogenic chordal rupture, five had infective endocarditis, 11 had mitral valve insufficiency, 23 had Ebstein's anomaly, and 47 had isolated severe TV incompetence. The basic principle was to reduce the distance between the coapting leaflets, wherein the most mobile leaflet could coapt to the opposite leaflet, by creating two orifices, ensuring valve competence. The TV repair was performed through a median sternotomy or right anterior thoracotomy in the fifth intercostal space under cardiopulmonary bypass. The degree and extent of creating a double-valve orifice was determined by considering the minimal body surface area (BSA)-related acceptable TV diameter. Repair was accomplished by passing pledgeted mattress sutures from the middle of the true anterior annulus to a spot on the opposite septal annulus, located approximately two-thirds of the length of the septal annulus to avoid injury to the bundle of His. The annular apposition divides the TV into a larger anterior and a smaller posterior orifices, enabling valve closure, on both sides. In adults, the diameter of the anterior valve orifice should be 23-25 mm, and the posterior orifice 15-18 mm; thus, the total valve orifice area is 5-6 cm2. In children, the total valve orifice should be a standard deviation of 1.7 mm for a BSA of 1.0m2. During a mean follow up of 8.7 ± 1.34 years (median 10 years; range: 1.5-25.9 years) there have been no reoperations for TV insufficiency

  15. Percutaneous aortic valve implantation of the Medtronic CoreValve self-expanding valve prosthesis via left subclavian artery access: the first case report in Greece.

    Science.gov (United States)

    Karavolias, George K; Georgiadou, Panagiota; Houri, Mazen; Sbarouni, Eftihia; Thomopoulou, Sofia; Tsiapras, Dimitrios; Smirli, Anna; Balanika, Marina; Voudris, Vassilis

    2010-01-01

    This case report describes a percutaneous aortic valve implantation with the Medtronic CoreValve selfexpanding valve prosthesis in a patient with severe aortic stenosis. The approach was made via the left subclavian artery because of the lack of femoral vessel access. The patient was a 78-year-old female with breathlessness on minimal effort, a recent hospitalisation due to pulmonary oedema, and frequent episodes of pre-syncope; surgical valve replacement had been ruled out. The prosthetic valve was successfully implanted with mild paravalvular aortic regurgitation. At 30 days, the patient's clinical condition had significantly improved, with excellent functioning of the aortic valve prosthesis.

  16. Ameliorative design for CARR safety rod drive mechanism

    International Nuclear Information System (INIS)

    Zhu Xuewei; Luo Zhong; Zhen Jianxiao; Wang Yulin

    2014-01-01

    The problem of safety rod accident dropped during C commissioning phase for China Advanced Research Reactor (CARR) was analyzed, and the reason was that the solenoid valve in safety rod drive mechanism (SRDM) driven loop was breakdown because of long-playing work. To solve this safe hidden trouble, SRDM was redesigned, and a new type of 'hydro lifting-hydro and electromagnetic holding' SRDM was presented, using Ansoft Maxwell to make a finite element analysis on new SRDM, working out electromagnetic field distribution and electromagnetic force of new SRDM. The results show that the value of electromagnetic force produced by electromagnetic force holding unit reaches 2.12 times about the weight of safety rod drive line, and it has some margins. (authors)

  17. Experimental investigations on the fluid-mechanics of an electrospun heart valve by means of particle image velocimetry.

    Science.gov (United States)

    Del Gaudio, Costantino; Gasbarroni, Pier Luca; Romano, Giovanni Paolo

    2016-12-01

    End-stage failing heart valves are currently replaced by mechanical or biological prostheses. Both types positively contribute to restore the physiological function of native valves, but a number of drawbacks limits the expected performances. In order to improve the outcome, tissue engineering can offer an alternative approach to design and fabricate innovative heart valves capable to support the requested function and to promote the formation of a novel, viable and correctly operating physiological structure. This potential result is particularly critical if referred to the aortic valve, being the one mainly exposed to structural and functional degeneration. In this regard, the here proposed study presents the fabrication and in vitro characterization of a bioresorbable electrospun heart valve prosthesis using the particle image velocimetry technique either in physiological and pathological fluid dynamic conditions. The scaffold was designed to reproduce the aortic valve geometry, also mimicking the fibrous structure of the natural extracellular matrix. To evaluate its performances for possible implantation, the flow fields downstream the valve were accurately investigated and compared. The experimental results showed a correct functionality of the device, supported by the formation of vortex structures at the edge of the three cusps, with Reynolds stress values below the threshold for the risk of hemolysis (which can be comprised in the range 400-4000N/m(2) depending on the exposure period), and a good structural resistance to the mechanical loads generated by the driving pressure difference. Copyright © 2016 Elsevier Ltd. All rights reserved.

  18. Flow oscillations on the steam control valve in the middle opening condition. Clarification of the effects of valve body and valve seat by steam experiments

    International Nuclear Information System (INIS)

    Morita, Ryo; Inada, Fumio

    2007-01-01

    A steam control valve might cause vibrations of piping when the valve opening is in a middle condition. For rationalization of maintenance and management of the plant, the valve should be improved, but it is difficult to understand flow characteristics in detail by experiment because flow around the valve is complex 3D structure and becomes supersonic (M>1). Therefore, it is necessary to clarify the cause of the vibrations and to develop the countermeasures by CFD (Computational Fluid Dynamics) technology. In previous researches, we clarified a mechanism of the pressure fluctuations in the middle opening condition and suggested the new valve shape (named 'Extended Valve') that can suppress the pressure fluctuations by air experiments and CFD calculations. Then, we also conducted steam experiments and CFD calculations to understand the differences between air and the steam, and found that the pressure fluctuations in the middle opening condition also occurred in the steam tests and the differences between the air and steam were not remarkable. In this report, to clarify the effects of valve and valve seat shape in steam flow condition, we conduct the steam experiments with various valve and seat shape. As a result, we find the change of the valve seat can decrease the amplitude of pressure fluctuations, but can not quite suppress the pressure fluctuations in the middle opening condition. Then, we apply the 'Extended Valve' to clarify the valve shape effect, and find that the extended valve suppresses the pressure fluctuations in the middle opening condition completely and decreases the pressure amplitude drastically. (author)

  19. Digital Dentistry — Digital Impression and CAD/CAM System Applications

    Directory of Open Access Journals (Sweden)

    Gabor Alin-Gabriel

    2017-03-01

    Full Text Available Digital imprint and computer-aided design/computer-aided manufacture (CAD/CAM systems offer several benefits compared to traditional techniques. The use of a CAD/CAM system to scan preparations and generate restorations in-office, removes a second appointment for the patient. The existence of precision benefits in using complete systems and chairside scanning systems, has been proven. CAD/CAM restorations have a good longevity and meet the accepted clinical parameters. New digital impression methods are presently accessible, and before long, the long-awaited goal of sparing patients of one the most unpleasant practices in clinical dentistry, acquiring dental impressions, will be exchanged by intraoral digital scanning. CAD/CAM systems existing nowadays, can feed data through accurate digital scans created from plaster models, straight to manufacturing systems that can shape ceramic or resin restorations with no requirement of a physical copy of the prepared, adjacent, and antagonist teeth.

  20. Effects of the blockage ratio of a valve disk on loss coefficient in a butterfly valve

    International Nuclear Information System (INIS)

    Rho, Hyung Joon; Lee, Jee Keun; Choi, Hee Joo

    2008-01-01

    The loss coefficient of the butterfly valve which allows partial opening of the valve at closed position and is applicable to the small-sized pipe system with the diameter of 1 inch was measured for the variation of the valve disk blockage ratio. Two different types of the valve disk configuration to adjust the blockage ratio were considered. One was the solid type valve disk of which the diameter was changed into the smaller size rather than the pipe diameter, and the other was the perforate type valve disk on which some holes were perforated. The results from two types of valve disk were compared to identify their characteristics in the loss coefficient distributions. The loss coefficient and the controllable angle of the valve disk were decreased exponentially with the decrease of the blockage ratio. In addition, the perforate valve disk had the effect on the higher loss coefficient rather than the solid type valve disk

  1. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. A valve plate is suspended from the box press by four guide wheels mounted thereon. The guide wheels are fitted into inclined guide grooves formed at the valve plate and into grooved formed in the inner wall of a valve casing. A locking ball is provided at each side of the valve plate. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing, thus releasing the locking balls. The valve plate does not contact the bottom of the casing. When the box press reaches the home position, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not slide over other parts. (Yamaguchi, T.)

  2. Comparison of denture tooth movement between CAD-CAM and conventional fabrication techniques.

    Science.gov (United States)

    Goodacre, Brian J; Goodacre, Charles J; Baba, Nadim Z; Kattadiyil, Mathew T

    2018-01-01

    Data comparing the denture tooth movement of computer-aided design and computer-aided manufacturing (CAD-CAM) and conventional denture processing techniques are lacking. The purpose of this in vitro study was to compare the denture tooth movement of pack-and-press, fluid resin, injection, CAD-CAM-bonded, and CAD-CAM monolithic techniques for fabricating dentures to determine which process produces the most accurate and reproducible prosthesis. A total of 50 dentures were evaluated, 10 for each of the 5 groups. A master denture was fabricated and milled from prepolymerized poly(methyl methacrylate). For the conventional processing techniques (pack-and-press, fluid resin, and injection) a polyvinyl siloxane putty mold of the master denture was made in which denture teeth were placed and molten wax injected. The cameo surface of each wax-festooned denture was laser scanned, resulting in a standard tessellation language (STL) format file. The CAD-CAM dentures included 2 subgroups: CAD-CAM-bonded teeth in which the denture teeth were bonded into the milled denture base and CAD-CAM monolithic teeth in which the denture teeth were milled as part of the denture base. After all specimens had been fabricated, they were hydrated for 24 hours, and the cameo surface laser scanned. The preprocessing and postprocessing scan files of each denture were superimposed using surface-matching software. Measurements were made at 64 locations, allowing evaluation of denture tooth movement in a buccal, lingual, mesial-distal, and occlusal direction. The use of median and interquartile range values was used to assess accuracy and reproducibility. Levene and Kruskal-Wallis analyses of variance were used to evaluate differences between processing techniques (α=.05). The CAD-CAM monolithic technique was the most accurate, followed by fluid resin, CAD-CAM-bonded, pack-and-press, and injection. CAD-CAM monolithic technique was the most reproducible, followed by pack-and-press, CAD-CAM

  3. Characterization of a bioprosthetic bicuspid venous valve hemodynamics: implications for mechanism of valve dynamics.

    Science.gov (United States)

    Tien, W-H; Chen, H Y; Berwick, Z C; Krieger, J; Chambers, S; Dabiri, D; Kassab, G S

    2014-10-01

    Chronic venous insufficiency (CVI) of the lower extremities is a common clinical problem. Although bioprosthetic valves have been proposed to treat severe reflux, clinical success has been limited due to thrombosis and neointima overgrowth of the leaflets that is, in part, related to the hemodynamics of the valve. A bioprosthetic valve that mimics native valve hemodynamics is essential. A computational model of the prosthetic valve based on realistic geometry and mechanical properties was developed to simulate the interaction of valve structure (fluid-structure interaction, FSI) with the surrounding flow. The simulation results were validated by experiments of a bioprosthetic bicuspid venous valve using particle image velocimetry (PIV) with high spatial and temporal resolution in a pulse duplicator (PD). Flow velocity fields surrounding the valve leaflets were calculated from PIV measurements and comparisons to the FSI simulation results were made. Both the spatial and temporal results of the simulations and experiments were in agreement. The FSI prediction of the transition point from equilibrium phase to valve-closing phase had a 7% delay compared to the PD measurements, while the PIV measurements matched the PD exactly. FSI predictions of reversed flow were within 10% compared to PD measurements. Stagnation or stasis regions were observed in both simulations and experiments. The pressure differential across the valve and associated forces on the leaflets from simulations showed the valve mechanism to be pressure driven. The flow velocity simulations were highly consistent with the experimental results. The FSI simulation and force analysis showed that the valve closure mechanism is pressure driven under the test conditions. FSI simulation and PIV measurements demonstrated that the flow behind the leaflet was mostly stagnant and a potential source for thrombosis. The validated FSI simulations should enable future valve design optimizations that are needed for

  4. The inducible CAM plants in putative lunar lander experiments

    Science.gov (United States)

    Burlak, Olexii; Zaetz, Iryna; Soldatkin, Olexii; Rogutskyy, Ivan; Danilchenko, Boris; Mikheev, Olexander; de Vera, Jean-Pierre; Vidmachenko, Anatolii; Foing, Bernard H.; Kozyrovska, Natalia

    Precursory lunar lander experiments on growing plants in locker-based chambers will increase our understanding of effect of lunar conditions on plant physiology. The inducible CAM (Cras-sulacean Acid Metabolism)-plants are reasonable model for a study of relationships between environmental challenges and changes in plant/bacteria gene expression. In inducible CAM-plants the enzymatic machinery for the environmentally activated CAM switches on from a C3-to a full-CAM mode of photosynthesis in response to any stresses (Winter et al., 2008). In our study, Kalanchoe spp. are shown to be promising candidates for putative lunar experiments as resistant to irradiation and desiccation, especially after inoculation with a bacterial consortium (Boorlak et al., 2010). Within frames of the experiment we expect to get information about the functional activity of CAM-plants, in particular, its organogenesis, photosystem, the circadian regulation of plant metabolism on the base of data gaining with instrumental indications from expression of the reporter genes fused to any genes involved in vital functions of the plant (Kozyrovska et al., 2009). References 1. Winter K., Garcia M., Holtum J. (2008) J. Exp. Bot. 59(7):1829-1840 2. Bourlak O., Lar O., Rogutskyy I., Mikheev A., Zaets I., Chervatyuk N., de Vera J.-P., Danilchenko A.B. Foing B.H., zyrovska N. (2010) Space Sci. Technol. 3. Kozyrovska N.O., Vidmachenko A.P., Foing B.H. et al. Exploration/call/estec/ESA. 2009.

  5. Small valve area index: its influence on early mortality after mitral valve replacement

    NARCIS (Netherlands)

    Yazdanbakhsh, A. P.; van den Brink, R. B.; Dekker, Egbert; de Mol, B. A.

    2000-01-01

    OBJECTIVE: To test the hypothesis that mitral valve prosthesis-patient mismatch increases postoperative mortality. METHODS AND RESULTS: The effect of mitral valve prosthesis-patient mismatch on survival in a cohort of consecutive patients after mitral valve replacement with a mechanical prosthesis

  6. Marginal adaptation and CAD-CAM technology: A systematic review of restorative material and fabrication techniques.

    Science.gov (United States)

    Papadiochou, Sofia; Pissiotis, Argirios L

    2018-04-01

    The comparative assessment of computer-aided design and computer-aided manufacturing (CAD-CAM) technology and other fabrication techniques pertaining to marginal adaptation should be documented. Limited evidence exists on the effect of restorative material on the performance of a CAD-CAM system relative to marginal adaptation. The purpose of this systematic review was to investigate whether the marginal adaptation of CAD-CAM single crowns, fixed dental prostheses, and implant-retained fixed dental prostheses or their infrastructures differs from that obtained by other fabrication techniques using a similar restorative material and whether it depends on the type of restorative material. An electronic search of English-language literature published between January 1, 2000, and June 30, 2016, was conducted of the Medline/PubMed database. Of the 55 included comparative studies, 28 compared CAD-CAM technology with conventional fabrication techniques, 12 contrasted CAD-CAM technology and copy milling, 4 compared CAD-CAM milling with direct metal laser sintering (DMLS), and 22 investigated the performance of a CAD-CAM system regarding marginal adaptation in restorations/infrastructures produced with different restorative materials. Most of the CAD-CAM restorations/infrastructures were within the clinically acceptable marginal discrepancy (MD) range. The performance of a CAD-CAM system relative to marginal adaptation is influenced by the restorative material. Compared with CAD-CAM, most of the heat-pressed lithium disilicate crowns displayed equal or smaller MD values. Slip-casting crowns exhibited similar or better marginal accuracy than those fabricated with CAD-CAM. Cobalt-chromium and titanium implant infrastructures produced using a CAD-CAM system elicited smaller MD values than zirconia. The majority of cobalt-chromium restorations/infrastructures produced by DMLS displayed better marginal accuracy than those fabricated with the casting technique. Compared with copy

  7. Gas exchange and leaf anatomy of a C3-CAM hybrid, Yucca gloriosa (Asparagaceae).

    Science.gov (United States)

    Heyduk, Karolina; Burrell, Nia; Lalani, Falak; Leebens-Mack, Jim

    2016-03-01

    While the majority of plants use the typical C3 carbon metabolic pathway, ~6% of angiosperms have adapted to carbon limitation as a result of water stress by employing a modified form of photosynthesis known as Crassulacean acid metabolism (CAM). CAM plants concentrate carbon in the cells by temporally separating atmospheric carbon acquisition from fixation into carbohydrates. CAM has been studied for decades, but the evolutionary progression from C3 to CAM remains obscure. In order to better understand the morphological and physiological characteristics associated with CAM photosynthesis, phenotypic variation was assessed in Yucca aloifolia, a CAM species, Yucca filamentosa, a C3 species, and Yucca gloriosa, a hybrid species derived from these two yuccas exhibiting intermediate C3-CAM characteristics. Gas exchange, titratable leaf acidity, and leaf anatomical traits of all three species were assayed in a common garden under well-watered and drought-stressed conditions. Yucca gloriosa showed intermediate phenotypes for nearly all traits measured, including the ability to acquire carbon at night. Using the variation found among individuals of all three species, correlations between traits were assessed to better understand how leaf anatomy and CAM physiology are related. Yucca gloriosa may be constrained by a number of traits which prevent it from using CAM to as high a degree as Y. aloifolia. The intermediate nature of Y. gloriosa makes it a promising system in which to study the evolution of CAM. © The Author 2015. Published by Oxford University Press on behalf of the Society for Experimental Biology.

  8. Perspectives of complementary and alternative medicine (CAM) practitioners in the support and treatment of infertility.

    Science.gov (United States)

    O'Reilly, Erin; Sevigny, Marika; Sabarre, Kelley-Anne; Phillips, Karen P

    2014-10-14

    Infertility patients are increasingly using complementary and alternative medicine (CAM) to supplement or replace conventional fertility treatments. The objective of this study was to determine the roles of CAM practitioners in the support and treatment of infertility. Ten semi-structured interviews were conducted in Ottawa, Canada in 2011 with CAM practitioners who specialized in naturopathy, acupuncture, traditional Chinese medicine, hypnotherapy and integrated medicine. CAM practitioners played an active role in both treatment and support of infertility, using a holistic, interdisciplinary and individualized approach. CAM practitioners recognized biological but also environmental and psychosomatic determinants of infertility. Participants were receptive to working with physicians, however little collaboration was described. Integrated infertility patient care through both collaboration with CAM practitioners and incorporation of CAM's holistic, individualized and interdisciplinary approaches would greatly benefit infertility patients.

  9. The use of CAM and conventional treatments among primary care consulters with chronic musculoskeletal pain

    Directory of Open Access Journals (Sweden)

    Lewis Martyn

    2007-05-01

    Full Text Available Abstract Background Chronic musculoskeletal pain is the single most cited reason for use of complementary and alternative medicine (CAM. Primary care is the most frequent conventional medical service used by patients with pain in the UK. We are unaware, however, of a direct evidence of the extent of CAM use by primary care patients, and how successful they perceive it to be. Methods Aims and objectives To determine CAM use among patients with chronic musculoskeletal pain who have consulted about their pain in primary care. Study design Face-to-face interview-based survey. Setting Three general practices in North Staffordshire. Participants Respondents to a population pain survey who had reported having musculoskeletal pain in the survey and who had consulted about their pain in primary care in the previous 12 months as well as consenting to further research and agreeing to an interview. Information was gathered about their pain and the use of all treatments for pain, including CAM, in the previous year. Results 138 interviews were completed. 116 participants (84% had used at least one CAM treatment for pain in the previous year. 65% were current users of CAM. The ratio of over-the-counter CAM use to care from a CAM provider was 3:2. 111 participants (80% had used conventional treatment. 95 (69% were using a combination of CAM and conventional treatment. Glucosamine and fish oil were the most commonly used CAM treatments (38%, 35% respectively. Most CAM treatments were scored on average as being helpful, and users indicated that they intended to use again 87% of the CAM treatments they had already used. Conclusion We provide direct evidence that most primary care consulters with chronic musculoskeletal pain have used CAM in the previous year, usually in combination with conventional treatments. The high prevalence and wide range of users experiences of benefit and harm from CAM strengthen the argument for more research into this type of medicine

  10. Björk-Shiley convexoconcave valves: susceptibility artifacts at brain MR imaging and mechanical valve fractures.

    Science.gov (United States)

    van Gorp, Maarten J; van der Graaf, Yolanda; de Mol, Bas A J M; Bakker, Chris J G; Witkamp, Theo D; Ramos, Lino M P; Mali, Willem P T M

    2004-03-01

    To assess the relationship between heart valve history and susceptibility artifacts at magnetic resonance (MR) imaging of the brain in patients with Björk-Shiley convexoconcave (BSCC) valves. MR images of the brain were obtained in 58 patients with prosthetic heart valves: 20 patients had BSCC valve replacements, and 38 had other types of heart valves. Two experienced neuroradiologists determined the presence or absence of susceptibility artifacts in a consensus reading. Artifacts were defined as characteristic black spots that were visible on T2*-weighted gradient-echo MR images. The statuses of the 20 explanted BSCC valves-specifically, whether they were intact or had an outlet strut fracture (OSF) or a single-leg fracture (SLF)-had been determined earlier. Number of artifacts seen at brain MR imaging was correlated with explanted valve status, and differences were analyzed with nonparametric statistical tests. Significantly more patients with BSCC valves (17 [85%] of 20 patients) than patients with other types of prosthetic valves (18 [47%] of 38 patients) had susceptibility artifacts at MR imaging (P =.005). BSCC valve OSFs were associated with a significantly higher number of artifacts than were intact BSCC valves (P =.01). No significant relationship between SLF and number of artifacts was observed. Susceptibility artifacts at brain MR imaging are not restricted to patients with BSCC valves. These artifacts can be seen on images obtained in patients with various other types of fractured and intact prosthetic heart valves. Copyright RSNA, 2004

  11. The CUPCIG (CAM-Use in Primary Care in Germany) Study:Part I-Pain. Study Protocol of a Pilot-trial to Assess Feasibility, Acceptability and Perceived Effectiveness of CAM in Pain Disorders in Primary Care.

    Science.gov (United States)

    Schencking, Martin; Sönnichsen, Andreas; Bassüner, Susanne; Redaelli, Marcus

    2015-01-01

    There is limited valid data available on CAM procedures for chronic joint and neuropathic pain in primary care in Germany. Indiviual CAM qualifications of the general practitioners (GPs) and the potential of cost reduction through CAM treatment are almost unknown. The aim of this pilot trial preceding the main study is to examine the survey mode, to estimate the response rate by GPs with or without an additional qualification for CAM, and to identify the status quo in therapeutic approaches for chronic pain disorders in primary care. This is a cross-sectional study with an ex post facto design among German GPs consisting of 2 parts: In a first step, a pilot trial precedes the main study targeting 200 GPs with and 200 GPs without additional qualification in CAM in a selected region. The results of the CUPCIG study comprise the distribution of pain types treated in primary care practices, the GPs' attitude toward complementary pain therapy, pharmacological or CAM treatment, the estimate of cost reduction through CAM treatment of pain, the application of diverse CAM procedures, and biographical data. The CUPCIG study serves to compile pain therapy approaches in primary care in Germany with respect to the individual CAM expertise of the GPs. © 2015 S. Karger GmbH, Freiburg.

  12. Low noise control valve

    International Nuclear Information System (INIS)

    Christie, R.S.

    1975-01-01

    Noise is one of the problems associated with the use of any type of control valve in systems involving the flow of fluids. The advent of OSHA standards has prompted control valve manufacturers to design valves with special trim to lower the sound pressure level to meet these standards. However, these levels are in some cases too high, particularly when a valve must be located in or near an area where people are working at tasks requiring a high degree of concentration. Such locations are found around and near research devices and in laboratory-office areas. This paper describes a type of fluid control device presently being used at PPL as a bypass control valve in deionized water systems and designed to reduce sound pressure levels considerably below OSHA standards. Details of the design and construction of this constant pressure drop variable flow control valve are contained in the text and are shown in photographs and drawings. Test data taken are included

  13. Introduction of effect and consideration of the introduction of CAD/CAM system

    International Nuclear Information System (INIS)

    Kang, Man Ok

    1984-12-01

    This reports introduction of effect and consideration of the introduction of computer-aided design and computer aided manufacturing system. It includes outline of CAD/CAM system like definition, classification, system kinds, and development process of CAD/CAM system, technology, market trend development prospect, and value on introduction of this system, and current application of CAD/CAM system in major application area, development countries and Korea.

  14. Idiopathic mitral valve prolapse with tricuspid, aortic and pulmonary valve involvement: An autopsy case report

    Directory of Open Access Journals (Sweden)

    Heena M Desai

    2015-01-01

    Full Text Available Mitral valve prolapse (MVP is usually asymptomatic, but can be associated with complications such as infective endocarditis, mitral regurgitation, thromboembolism and sudden cardiac death. It has been very rarely reported to occur in association with other valvular involvement. A 55-year-old male patient was brought dead and at autopsy the mitral valve orifice was stenotic and the leaflets were enlarged, myxoid and bulging suggestive of MVP and chordae tendinae were thickened, stretched and elongated. Similar changes were seen in the tricuspid valve. The pulmonary and aortic valves also showed myxomatous degeneration of their cusps. Myxomatous degeneration is the most common cause of MVP and it can be associated with involvement of the other valves. Concomitant involvement of the aortic valve has been reported, however it is very rare and simultaneous involvement of the pulmonary valve has not been reported in the literature so far. We report a case of MVP associated with myxomatous degeneration of the tricuspid, pulmonary and aortic valves.

  15. Child/Adolescent Anxiety Multimodal Study (CAMS: rationale, design, and methods

    Directory of Open Access Journals (Sweden)

    Waslick Bruce D

    2010-01-01

    Full Text Available Abstract Objective To present the design, methods, and rationale of the Child/Adolescent Anxiety Multimodal Study (CAMS, a recently completed federally-funded, multi-site, randomized placebo-controlled trial that examined the relative efficacy of cognitive-behavior therapy (CBT, sertraline (SRT, and their combination (COMB against pill placebo (PBO for the treatment of separation anxiety disorder (SAD, generalized anxiety disorder (GAD and social phobia (SoP in children and adolescents. Methods Following a brief review of the acute outcomes of the CAMS trial, as well as the psychosocial and pharmacologic treatment literature for pediatric anxiety disorders, the design and methods of the CAMS trial are described. Results CAMS was a six-year, six-site, randomized controlled trial. Four hundred eighty-eight (N = 488 children and adolescents (ages 7-17 years with DSM-IV-TR diagnoses of SAD, GAD, or SoP were randomly assigned to one of four treatment conditions: CBT, SRT, COMB, or PBO. Assessments of anxiety symptoms, safety, and functional outcomes, as well as putative mediators and moderators of treatment response were completed in a multi-measure, multi-informant fashion. Manual-based therapies, trained clinicians and independent evaluators were used to ensure treatment and assessment fidelity. A multi-layered administrative structure with representation from all sites facilitated cross-site coordination of the entire trial, study protocols and quality assurance. Conclusions CAMS offers a model for clinical trials methods applicable to psychosocial and psychopharmacological comparative treatment trials by using state-of-the-art methods and rigorous cross-site quality controls. CAMS also provided a large-scale examination of the relative and combined efficacy and safety of the best evidenced-based psychosocial (CBT and pharmacologic (SSRI treatments to date for the most commonly occurring pediatric anxiety disorders. Primary and secondary results

  16. PhenoCam Dataset v1.0: Digital Camera Imagery from the PhenoCam Network, 2000-2015

    Data.gov (United States)

    National Aeronautics and Space Administration — This dataset provides a time series of visible-wavelength digital camera imagery collected through the PhenoCam Network at each of 133 sites in North America and...

  17. Valve for closing a steam line

    International Nuclear Information System (INIS)

    Meyer, W.; Potrykus, G.

    1976-01-01

    Instead of several control elements, the quick-closing valve, especially in the main-steam line between steam generator and turbine of a power station has the valve cone itself as the only movable part, acting with its inner surface as a piston within a second cylinder space. The valve shaft is at the same time a piston rod with a stepped piston at the upper end. This piston is loaded in a cylinder at the upspace below the valve cover on one hand by a spring, on the other hand by its own medium. Two non-return valves, one of it in a bore of the valve cone, connect the first-mentioned cylinder space with the steam-loaded inlet resp. outlet side of the valve. For controlling the valve, a magnet valve is sufficient. By automatic control of the valve cone coupled with several pistons several control lines can be omitted. There are also no pressurized control lines outside the valve which could be damaged by exterior influences. (ERA) [de

  18. Day/night regulation of aquaporins during the CAM cycle in Mesembryanthemum crystallinum.

    Science.gov (United States)

    Vera-Estrella, Rosario; Barkla, Bronwyn J; Amezcua-Romero, Julio C; Pantoja, Omar

    2012-03-01

    Mesembryanthemum crystallinum exhibits induction of Crassulacean acid metabolism (CAM) after a threshold stage of development, by exposure to long days with high light intensities or by water and salt stress. During the CAM cycle, fluctuations in carbon partitioning within the cell lead to transient drops in osmotic potential, which are likely stabilized/balanced by passive movement of water via aquaporins (AQPs). Protoplast swelling assays were used to detect changes in water permeability during the day/night cycle of CAM. To assess the role of AQPs during the same period, we followed transcript accumulation and protein abundance of four plasma membrane intrinsic proteins (PIPs) and one tonoplast intrinsic protein (TIP). CAM plants showed a persistent rhythm of specific AQP protein abundance changes throughout the day/night cycle, including changes in amount of McPIP2;1, McTIP1;2, McPIP1;4 and McPIP1;5, while the abundance of McPIP1;2 was unchanged. These protein changes did not appear to be coordinated with transcript levels for any of the AQPs analysed; however, they did occur in parrallel to alterations in water permeability, as well as variations in cell osmolarity, pinitol, glucose, fructose and phosphoenolpyruvate carboxylase (PEPc) levels measured throughout the day/night CAM cycle. Results suggest a role for AQPs in maintaining water balance during CAM and highlight the complexity of protein expression during the CAM cycle. © 2011 Blackwell Publishing Ltd.

  19. A methodological framework for evaluating the evidence for Complementary and Alternative Medicine (CAM) for cancer

    DEFF Research Database (Denmark)

    Zachariae, Robert; Johannesen, Helle

    2011-01-01

    In spite of lacking evidence for effects on cancer progression itself, an increasing number of cancer patients use various types of complementary and alternative medicine (CAM). There is disagreement between CAM practitioners, researchers and clinical oncologists, as to how evidence concerning...... effects of CAM can and should be produced, and how the existing evidence should be interpreted. This represents a considerable challenge for oncologists; both in terms of patient needs for an informed dialogue regarding CAM, and because some types of CAM may interact with standard treatments....... There is a need for insight into which kinds of CAM may work, for whom they work, what the possible effects and side-effects are, and in what ways such effects may come about. The present article presents a framework for evaluating effects of CAM by suggesting a taxonomy of different levels of evidence related...

  20. Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

    Science.gov (United States)

    Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.

    2015-01-01

    It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since

  1. Analysis of water hammer in control rod drive systems of boiling water reactor nuclear power plants

    International Nuclear Information System (INIS)

    Safwat, H.H.; Arastu, A.H.; Lau, S.

    1983-01-01

    The method of characteristics is applied to analyze water hammer in BWR (Boiling Water Reactor) Control Rod Drive (CRD) Systems following fast opening of scram valves. The modelling of the CRD mechanism is presented. Numerical predictions are compared to experimental data. (author)

  2. Phenotype-dependent effects of EpCAM expression on growth and invasion of human breast cancer cell lines

    International Nuclear Information System (INIS)

    Martowicz, Agnieszka; Spizzo, Gilbert; Gastl, Guenther; Untergasser, Gerold

    2012-01-01

    The epithelial cell adhesion molecule (EpCAM) has been shown to be overexpressed in breast cancer and stem cells and has emerged as an attractive target for immunotherapy of breast cancer patients. This study analyzes the effects of EpCAM on breast cancer cell lines with epithelial or mesenchymal phenotype. For this purpose, shRNA-mediated knockdown of EpCAM gene expression was performed in EpCAM high breast cancer cell lines with epithelial phenotype (MCF-7, T47D and SkBR3). Moreover, EpCAM low breast carcinoma cell lines with mesenchymal phenotype (MDA-MB-231, Hs578t) and inducible overexpression of EpCAM were used to study effects on proliferation, migration and in vivo growth. In comparison to non-specific silencing controls (n/s-crtl) knockdown of EpCAM (E#2) in EpCAM high cell lines resulted in reduced cell proliferation under serum-reduced culture conditions. Moreover, DNA synthesis under 3D culture conditions in collagen was significantly reduced. Xenografts of MCF-7 and T47D cells with knockdown of EpCAM formed smaller tumors that were less invasive. EpCAM low cell lines with tetracycline-inducible overexpression of EpCAM showed no increased cell proliferation or migration under serum-reduced growth conditions. MDA-MB-231 xenografts with EpCAM overexpression showed reduced invasion into host tissue and more infiltrates of chicken granulocytes. The role of EpCAM in breast cancer strongly depends on the epithelial or mesenchymal phenotype of tumor cells. Cancer cells with epithelial phenotype need EpCAM as a growth- and invasion-promoting factor, whereas tumor cells with a mesenchymal phenotype are independent of EpCAM in invasion processes and tumor progression. These findings might have clinical implications for EpCAM-based targeting strategies in patients with invasive breast cancer

  3. An Energy Efficient Hydraulic Winch Drive Concept Based on a Speed-variable Switched Differential Pump

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben O.; Pedersen, Henrik Clemmensen

    2017-01-01

    controls. Such solutions are typically constituted by many and rather expensive components, and are furthermore often suffering from low frequency dynamics. In this paper an alternative solution is proposed for winch drive operation, which is based on the so-called speed-variable switched differential pump......, originally designed for direct drive of hydraulic differential cylinders. This concept utilizes three pumps, driven by a single electric servo drive. The concept is redesigned for usage in winch drives, driven by flow symmetric hydraulic motors and single directional loads as commonly seen in e.g. active...... heave compensation applications. A general drive configuration approach is presented, along with a proper control strategy and design. The resulting concept is evaluated when applied for active heave compensation. Results demonstrate control performance on level with conventional valve solutions...

  4. Door valve for fuel handling path

    International Nuclear Information System (INIS)

    Makishima, Katsuhiko.

    1969-01-01

    A door valve is provided which seals cover gas from a liquid metal cooled reactor without leakage therefrom. A threaded shaft is screwed into a heavy box press which is packed with lead. The shaft is adapted to be rotated by an electric motor or a manually operated wheel which is disposed outside of the door valve. From the box press a valve plate is suspended by four linkage bars, one for each corner. Each linkage bar is provided with two wheels which are respectively mounted at the connections with the box press and the valve plate. The wheels are carried on the horizontal grooves formed in a door valve casing. In operation the shaft rotates and travels to permit the box press and the valve plate to move into the door valve casing while the valve plate does not contact the casing. When the box press reaches the home position, the wheels drop into the recesses which are disposed at the ends of the grooves, the valve plate is carried on the valve opening, and the box press presses the valve plate to increase the tightness. The valve plate does not suffer wear as it does not over other parts. (Yamaguchi, T.)

  5. Longevity of Single-Tooth All-Ceramic CAD/CAM Restorations: A Meta-Analysis

    Science.gov (United States)

    2013-07-01

    to the application of CAD/CAM technology in dentistry . The initial monetary investment for the equipment is significant. Systems currently on the...CURRENT DENTAL CAD/CAM SYSTEMS Current CAD/CAM systems in dentistry include: CEREC (CEramic REConstruction) and CEREC Acquisition Center (AC) with...of Adhesive Dentistry , 1 (3), 255- 265. 42     Bindl A, & Mörmann W. (2002). An up to 5-year clinical evaluation of posterior In- Ceram CAD

  6. Availability Analysis of the Ventilation Stack CAM Interlock System

    CERN Document Server

    Young, J

    2000-01-01

    Ventilation Stack Continuous Air Monitor (CAM) Interlock System failure modes, failure frequencies, and system availability have been evaluated for the RPP. The evaluation concludes that CAM availability is as high as assumed in the safety analysis and that the current routine system surveillance is adequate to maintain this availability credited in the safety analysis, nor is such an arrangement predicted to significantly improve system availability.

  7. Impact of bicuspid aortic valve on complications and death in infective endocarditis of native aortic valves.

    Science.gov (United States)

    Kahveci, Gokhan; Bayrak, Fatih; Pala, Selcuk; Mutlu, Bulent

    2009-01-01

    We retrospectively investigated the impact of bicuspid aortic valve on the prognosis of patients who had definite infective endocarditis of the native aortic valve.Of 51 patients, a bicuspid aortic valve was present in 22 (43%); the other 29 had tricuspid aortic valves. On average, the patients who had bicuspid valves were younger than those who had tricuspid valves. Patients with a tricuspid valve had larger left atrial diameters and were more likely to have severe mitral regurgitation.Periannular complications, which we detected in 19 patients (37%), were much more common in the patients who had a bicuspid valve (64% vs 17%, P = 0.001). The presence of a bicuspid valve was the only significant independent predictor of periannular complications. The in-hospital mortality rate in the bicuspid group was lower than that in the tricuspid group; however, this figure did not reach statistical significance (9% vs 24%, P = 0.15). In multivariate analysis, left atrial diameter was the only independent predictor associated with an increased risk of death (hazard ratio, 2.19; 95% confidence interval, 1.1-4.5; P = 0.031).In our study, patients with infective endocarditis in a bicuspid aortic valve were younger and had a higher incidence of periannular complications. Although a worse prognosis has been reported previously, we found that infective endocarditis in a native bicuspid aortic valve is not likely to increase the risk of death in comparison with infective endocarditis in native tricuspid aortic valves.

  8. Gate valve performance prediction

    International Nuclear Information System (INIS)

    Harrison, D.H.; Damerell, P.S.; Wang, J.K.; Kalsi, M.S.; Wolfe, K.J.

    1994-01-01

    The Electric Power Research Institute is carrying out a program to improve the performance prediction methods for motor-operated valves. As part of this program, an analytical method to predict the stem thrust required to stroke a gate valve has been developed and has been assessed against data from gate valve tests. The method accounts for the loads applied to the disc by fluid flow and for the detailed mechanical interaction of the stem, disc, guides, and seats. To support development of the method, two separate-effects test programs were carried out. One test program determined friction coefficients for contacts between gate valve parts by using material specimens in controlled environments. The other test program investigated the interaction of the stem, disc, guides, and seat using a special fixture with full-sized gate valve parts. The method has been assessed against flow-loop and in-plant test data. These tests include valve sizes from 3 to 18 in. and cover a considerable range of flow, temperature, and differential pressure. Stem thrust predictions for the method bound measured results. In some cases, the bounding predictions are substantially higher than the stem loads required for valve operation, as a result of the bounding nature of the friction coefficients in the method

  9. System Design and Analysis of a Directly Air-Assisted Turbocharged SI Engine with Camshaft Driven Valves

    Directory of Open Access Journals (Sweden)

    Lino Guzzella

    2013-03-01

    Full Text Available The availability of compressed air in combination with downsizing and turbocharging is a promising approach to improve the fuel economy and the driveability of internal combustion engines. The compressed air is used to boost and start the engine. It is generated during deceleration phases by running the engine as a piston compressor. In this paper, a camshaft-driven valve is considered for the control of the air exchange between the tank and the combustion chamber. Such a valve system is cost-effective and robust. Each pneumatic engine mode is realized by a separate cam. The air mass transfer in each mode is analyzed. Special attention is paid to the tank pressure dependence. The air demand in the boost mode is found to increase with the tank pressure. However, the dependence on the tank pressure is small in the most relevant operating region. The air demand of the pneumatic start shows a piecewise continuous dependence on the tank pressure. Finally, a tank sizing method is proposed which uses a quasi-static simulation. It is applied to a compact class vehicle, for which a tank volume of less than 10 L is sufficient. A further reduction of the tank volume is limited by the specifications imposed on the pneumatic start.

  10. Mitral Valve Prolapse

    Science.gov (United States)

    ... valve syndrome . What happens during MVP? Watch an animation of mitral valve prolapse When the heart pumps ( ... our brochures Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  11. Comparison of Flexural Strength of Different CAD/CAM PMMA-Based Polymers.

    Science.gov (United States)

    Alp, Gülce; Murat, Sema; Yilmaz, Burak

    2018-01-28

    To compare the flexural strength of different computer-aided design/computer-aided manufacturing (CAD/CAM) poly(methyl methacrylate)-based (PMMA) polymers and conventional interim resin materials after thermocycling. Rectangular-shaped specimens (n = 15, for each material) (25 × 2 × 2 mm 3 ) were fabricated from 3 CAD/CAM PMMA-based polymers (Telio CAD [T]; M-PM-Disc [M]; Polident-PMMA [P]), 1 bis-acrylate composite resin (Protemp 4 [PT]), and 1 conventional PMMA (ArtConcept Artegral Dentine [C]) according to ISO 10477:2004 Standards (Dentistry-Polymer-Based Crown and Bridge Materials). The specimens were subjected to 10,000 thermocycles (5 to 55°C). Three-point flexural strength of the specimens was tested in a universal testing machine at a 1.0 mm/min crosshead speed, and the flexural strength data (σ) were calculated (MPa). The flexural strength values were statistically analyzed using 1-way ANOVA, and Tukey HSD post-hoc test for multiple comparisons (α = 0.05). Flexural strength values ranged between 66.1 ± 13.1 and 131.9 ± 19.8 MPa. There were significant differences among the flexural strengths of tested materials, except for between T and P CAD/CAM PMMA-based polymers (p > 0.05). CAD/CAM PMMA-based polymer M had the highest flexural strength and conventional PMMA had the lowest (p CAD/CAM PMMA-based T and P polymers had significantly higher flexural strength than the bis-acrylate composite resin (p CAD/CAM PMMA-based M (p CAD/CAM PMMA-based polymers was greater than the flexural strength of bis-acrylate composite resin, which had a greater flexural strength compared to conventional PMMA resin. © 2018 by the American College of Prosthodontists.

  12. Application of ceramics to the sliding seat of valve bridge; Valve bridge yodobu eno ceramics tekiyo

    Energy Technology Data Exchange (ETDEWEB)

    Matsui, T; Ono, T [Mitsubishi Motors Corp., Tokyo (Japan)

    1997-10-01

    For use in the valve train, using an OHV (over head valve) configuration. of a 4 valve diesel engine for trucks and buses; we developed a valve bridge, a component of a valve train, with a ceramic head that is made of silicon nitride(Si3N4) in contact with a rocker arm in order to reduce cost and improve wear resistance for further diesel engine emissions regulations. In order to evaluate the effect of this valve bridge, RIG tests and durability tests on actual engines were carried out. 7 figs., 2 tabs.

  13. Do CAD/CAM dentures really release less monomer than conventional dentures?

    Science.gov (United States)

    Steinmassl, Patricia-Anca; Wiedemair, Verena; Huck, Christian; Klaunzer, Florian; Steinmassl, Otto; Grunert, Ingrid; Dumfahrt, Herbert

    2017-06-01

    Computer-aided design (CAD)/computer-aided manufacturing (CAM) dentures are assumed to have more favourable material properties than conventionally fabricated dentures, among them a lower methacrylate monomer release. The aim of this study was to test this hypothesis. CAD/CAM dentures were generated from ten different master casts by using four different CAD/CAM systems. Conventional, heat-polymerised dentures served as control group. Denture weight and volume were measured; the density was calculated, and the denture surface area was assessed digitally. The monomer release after 7 days of water storage was measured by high-performance liquid chromatography. Whole You Nexteeth and Wieland Digital Dentures had significantly lower mean volume and weight than conventional dentures. Baltic Denture System and Whole You Nexteeth had a significantly increased density. Baltic Denture System had a significantly smaller surface area. None of the CAD/CAM dentures released significantly less monomer than the control group. All tested dentures released very low amounts of methacrylate monomer, but not significantly less than conventional dentures. A statistically significant difference might nevertheless exist in comparison to other, less recommendable denture base materials, such as the frequently used autopolymerising resins. CAD/CAM denture fabrication has numerous advantages. It enables the fabrication of dentures with lower resin volume and lower denture weight. Both could increase the patient comfort. Dentures with higher density might exhibit more favourable mechanical properties. The hypothesis that CAD/CAM dentures release less monomer than conventional dentures could, however, not be verified.

  14. Transcatheter Mitral Valve-in-Ring Implantation

    LENUS (Irish Health Repository)

    Tanner, RE

    2018-05-01

    Failed surgical mitral valve repair using an annuloplasty ring has traditionally been treated with surgical valve replacement or repair1. For patients at high risk for repeat open heart surgery, placement of a trans-catheter aortic valve (i.e., TAVI valve) within the mitral ring (i.e., Mitral-Valve-in-Ring, MViR) has emerged as a novel alternative treatment strategy2-5 . We describe our experience of a failed mitral valve repair that was successfully treated with a TAVI valve delivered via the trans-septal approach, and summarise the data relating to this emerging treatment strategy.

  15. A new one-step procedure for pulmonary valve implantation of the melody valve: Simultaneous prestenting and valve implantation.

    Science.gov (United States)

    Boudjemline, Younes

    2018-01-01

    To describe a new modification, the one-step procedure, that allows interventionists to pre-stent and implant a Melody valve simultaneously. Percutaneous pulmonary valve implantation (PPVI) is the standard of care for managing patients with dysfunctional right ventricular outflow tract, and the approach is standardized. Patients undergoing PPVI using the one-step procedure were identified in our database. Procedural data and radiation exposure were compared to those in a matched group of patients who underwent PPVI using the conventional two-step procedure. Between January 2016 and January 2017, PPVI was performed in 27 patients (median age/range, 19.1/10-55 years) using the one-step procedure involving manual crimping of one to three bare metal stents over the Melody valve. The stent and Melody valve were delivered successfully using the Ensemble delivery system. No complications occurred. All patients had excellent hemodynamic results (median/range post-PPVI right ventricular to pulmonary artery gradient, 9/0-20 mmHg). Valve function was excellent. Median procedural and fluoroscopic times were 56 and 10.2 min, respectively, which significantly differed from those of the two-step procedure group. Similarly, the dose area product (DAP), and radiation time were statistically lower in the one-step group than in the two-step group (P step procedure is a safe modification that allows interventionists to prestent and implants the Melody valve simultaneously. It significantly reduces procedural and fluoroscopic times, and radiation exposure. © 2017 Wiley Periodicals, Inc.

  16. Space Vehicle Valve System

    Science.gov (United States)

    Kelley, Anthony R. (Inventor); Lindner, Jeffrey L. (Inventor)

    2014-01-01

    The present invention is a space vehicle valve system which controls the internal pressure of a space vehicle and the flow rate of purged gases at a given internal pressure and aperture site. A plurality of quasi-unique variable dimension peaked valve structures cover the purge apertures on a space vehicle. Interchangeable sheet guards configured to cover valve apertures on the peaked valve structure contain a pressure-activated surface on the inner surface. Sheet guards move outwardly from the peaked valve structure when in structural contact with a purge gas stream flowing through the apertures on the space vehicle. Changing the properties of the sheet guards changes the response of the sheet guards at a given internal pressure, providing control of the flow rate at a given aperture site.

  17. Transcatheter valve-in-valve implantation due to severe aortic regurgitation in a degenerated aortic homograft

    DEFF Research Database (Denmark)

    Olsen, Lene Kjaer; Engstrøm, Thomas; Søndergaard, Lars

    2009-01-01

    Transcatheter aortic valve implantation (TAVI) in severe aortic stenosis has proven to be a feasible and effective treatment modality for inoperable patients. Until now, neither aortic regurgitation nor degenerated bioprostheses has been an indication for TAVI. However, this article reports...... a successful valve-in-valve implantation of a CoreValve aortic valve prosthesis through the right subclavian artery in a case of severe aortic regurgitation within a degenerated aortic homograft. The case exemplifies the possibilities of expanding the indications for TAVI, as well as other vascular access...

  18. Thermally induced pressure locking of gate valves: A survey of valve bonnet pressurization rates

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Moore, W.E.

    1996-01-01

    Closed, water filled gate valves run the risk of becoming pressurized due to heat input from the environment or from adjacent connected piping. Thermal pressurization of gate valve bonnets may lead to the valves failing to open on demand and can even induce structural failure of valves. This paper presents an analytical prediction of the pressurization rate of a closed pressure vessel subject to uniform heating which may be considered as an upper bound to the pressurization rate that may occur in the field. Then actual valve experiences described in the literature are reviewed to determine the expected pressurization rate in existing hardware designs. A statistical approach is applied to reconcile the differing pressurization rates reported in the literature and determine a rate that can be applied in valve evaluations. The limitations of the reconciled rate are discussed

  19. Sobre figuras de oposição em dois sonetos de Camões

    OpenAIRE

    Marnoto, Rita

    2012-01-01

    (2012). Sobre figuras de oposição em dois sonetos de Camões. In Rita Marnoto (Coord.), Comentário a Camões. Vol. 1. Sonetos (147-204). Lisboa: CIEC, Cotovia. ISBN 978 972 795 330 1 figuras de oposição, visão histórica e seu uso em dois sonetos de Camões

  20. Colombian experience with transcatheter aortic valve implantation of medtronic CoreValve.

    Science.gov (United States)

    Dager, Antonio E; Nuis, Rutger-Jan; Caicedo, Bernardo; Fonseca, Jaime A; Arana, Camilo; Cruz, Lidsa; Benitez, Luis M; Nader, Carlos A; Duenas, Eduardo; de Marchena, Eduardo J; O'Neill, William W; de Jaegere, Peter P

    2012-01-01

    At our institutions, increasing numbers of aortic stenosis patients were not candidates for surgical aortic valve replacement. Accordingly, we initiated the Cali Colombian Transcatheter Aortic Valve Implantation (TAVI) program. From March 2008 through January 2011, 53 consecutive patients (mean age, 79 ± 6 yr; men, 58%) underwent TAVI with the Medtronic CoreValve System, and data were prospectively collected. Our study's endpoints conformed with Valve Academic Research Consortium recommendations. We report our clinical results.Predicted mortality rates were 25% (interquartile range, 17%-34%) according to logistic EuroSCORE and 6% (interquartile range, 3%-8%) according to the Society of Thoracic Surgeons score. The 30-day mortality rate was 9% (3 intraprocedural deaths, 5 total). The combined 30-day safety endpoint was 30% (major vascular sequelae, 23%; life-threatening bleeding, 12%; myocardial infarction, 4%; major stroke, 4%; and acute kidney injury [stage 3], 2%). Eight patients (15%) required post-implantation balloon dilation and 2 (4%) required valve-in-valve implantation, for a technical device success rate of 77%. Mean peak transvalvular gradient decreased from 74 ± 29 to 17 ± 8 mmHg and mean transvalvular gradient from 40 ± 17 to 8 ± 4 mmHg (both P=0.001). Moderate or severe aortic regurgitation decreased from 32% to 18% (P=0.12) and mitral regurgitation from 32% to 13% (P=0.002). The 1-year survival rate was 81%.We found that TAVI with the CoreValve prosthesis was safe and feasible, with sustained long-term results, for treating aortic stenosis in patients at excessive surgical risk; nonetheless, serious adverse events occurred in 30% of the patients.

  1. Traumatic Mitral Valve and Pericardial Injury

    Directory of Open Access Journals (Sweden)

    Nissar Shaikh

    2013-01-01

    Full Text Available Cardiac injury after blunt trauma is common but underreported. Common cardiac trauma after the blunt chest injury (BCI is cardiac contusion; it is very rare to have cardiac valve injury. The mitral valve injury during chest trauma occurs when extreme pressure is applied at early systole during the isovolumic contraction between the closure of the mitral valve and the opening of the aortic valve. Traumatic mitral valve injury can involve valve leaflet, chordae tendineae, or papillary muscles. For the diagnosis of mitral valve injury, a high index of suspicion is required, as in polytrauma patients, other obvious severe injuries will divert the attention of the treating physician. Clinical picture of patients with mitral valve injury may vary from none to cardiogenic shock. The echocardiogram is the main diagnostic modality of mitral valve injuries. Patient’s clinical condition will dictate the timing and type of surgery or medical therapy. We report a case of mitral valve and pericardial injury in a polytrauma patient, successfully treated in our intensive care unit.

  2. Understanding dental CAD/CAM for restorations--the digital workflow from a mechanical engineering viewpoint.

    Science.gov (United States)

    Tapie, L; Lebon, N; Mawussi, B; Fron Chabouis, H; Duret, F; Attal, J-P

    2015-01-01

    As digital technology infiltrates every area of daily life, including the field of medicine, so it is increasingly being introduced into dental practice. Apart from chairside practice, computer-aided design/computer-aided manufacturing (CAD/CAM) solutions are available for creating inlays, crowns, fixed partial dentures (FPDs), implant abutments, and other dental prostheses. CAD/CAM dental solutions can be considered a chain of digital devices and software for the almost automatic design and creation of dental restorations. However, dentists who want to use the technology often do not have the time or knowledge to understand it. A basic knowledge of the CAD/CAM digital workflow for dental restorations can help dentists to grasp the technology and purchase a CAM/CAM system that meets the needs of their office. This article provides a computer-science and mechanical-engineering approach to the CAD/CAM digital workflow to help dentists understand the technology.

  3. CAM therapies among primary care patients using opioid therapy for chronic pain

    OpenAIRE

    Fleming, Sara; Rabago, David P; Mundt, Marlon P; Fleming, Michael F

    2007-01-01

    Abstract Background Complementary and alternative medicine (CAM) is an increasingly common therapy used to treat chronic pain syndromes. However; there is limited information on the utilization and efficacy of CAM therapy in primary care patients receiving long-term opioid therapy. Method A survey of CAM therapy was conducted with a systematic sample of 908 primary care patients receiving opioids as a primary treatment method for chronic pain. Subjects completed a questionnaire designed to as...

  4. Mechanisms of mechanical heart valve cavitation: investigation using a tilting disk valve model.

    Science.gov (United States)

    He, Z; Xi, B; Zhu, K; Hwang, N H

    2001-09-01

    The induction of mechanical heart valve (MHV) cavitation was investigated using a 27 mm Medtronic Hall (MH27) tilting disk valve. The MH27 valve was mounted in the mitral position of a simulating pulse flow system, and stroboscopic lighting used to visualize cavitation bubbles on the occluder inflow surface at the instant of valve closure. MHV cavitation was monitored using a digital camera with 0.04 mm/pixel resolution sufficient to render the tiny bubbles clearly visible on the computer monitor screen. Cavitation on MH27 valve was classified as five types according to the time, site and shape of the cavitation bubbles. Valve cavitation occurred at the instant of occluder impact with the valve seat at closing. The impact motion was subdivided into three temporal phases: (i) squeezing flow; (ii) elastic collision; and (iii) leaflet rebound. MHV cavitation caused by vortices was found to be initiated by the squeezing jet and/or by the transvalvular leakage jets. By using a tension wave which swept across the occluder surface immediately upon elastic impact, nuclei in the vortex core were expanded to form cavitation bubbles. Analysis of the shape and location of the cavitation bubbles permitted a better understanding of MHV cavitation mechanisms, based on the fluid dynamics of jet vortex and tension wave propagations.

  5. Fairchild Stratos Division's Type II prototype lockhopper valve: METC Prototype Test Valve No. F-1 prototype lockhopper valve-testing and development project. Static test report

    Energy Technology Data Exchange (ETDEWEB)

    Goff, D. R.; Cutright, R. L.; Griffith, R. A.; Loomis, R. B.; Maxfield, D. A.; Moritz, R. S.

    1981-10-01

    METC Prototype Test Valve No. F-1 is a hybrid design, based on a segmented ball termed a visor valve, developed and manufactured by Fairchild Stratos Division under contract to the Department of Energy. The valve uses a visor arm that rotates into position and then translates to seal. This valve conditionally completed static testing at METC with clean gas to pressures of 1600 psig and internal valve temperatures to 600/sup 0/F. External leakage was excessive due to leakage through the stuffing box, purge fittings, external bolts, and other assemblies. The stuffing box was repacked several times and redesigned midway through the testing, but external leakage was still excessive. Internal leakage through the seats, except for a few anomalies, was very low throughout the 2409 cycles of testing. As shown by the low internal leakage, the visor valve concept appears to have potential for lock-hopper valve applications. The problems that are present with METC Prototype Test Valve No. F-1 are in the seals, which are equivalent to the shaft and bonnet seals in standard valve designs. The operating conditions at these seals are well within the capabilities of available seal designs and materials. Further engineering and minor modifications should be able to resolve the problems identified during static testing.

  6. Treatment expectations for CAM interventions in pediatric chronic pain patients and their parents.

    Science.gov (United States)

    Tsao, Jennie C I; Meldrum, Marcia; Bursch, Brenda; Jacob, Margaret C; Kim, Su C; Zeltzer, Lonnie K

    2005-12-01

    Patient expectations regarding complementary and alternative medicine (CAM) interventions have important implications for treatment adherence, attrition and clinical outcome. Little is known, however, about parent and child treatment expectations regarding CAM approaches for pediatric chronic pain problems. The present study examined ratings of the expected benefits of CAM (i.e. hypnosis, massage, acupuncture, yoga and relaxation) and conventional medicine (i.e. medications, surgery) interventions in 45 children (32 girls; mean age = 13.8 years +/- 2.5) and parents (39 mothers) presenting for treatment at a specialty clinic for chronic pediatric pain. Among children, medications and relaxation were expected to be significantly more helpful than the remaining approaches (P CAM to be fairly low with parents' expectations only somewhat more positive. The current findings suggest that educational efforts directed at enhancing treatment expectations regarding CAM, particularly among children with chronic pain, are warranted.

  7. Luís de Camões - O Lírico

    Directory of Open Access Journals (Sweden)

    Sigismundo Spina

    1953-03-01

    Full Text Available CIDADE (Hernani. - Luís de Camões - O Lírico . Livraria Bertrand, Lisboa, 1952. 354 pp. (Primeiro Parágrafo do Artigo Os estudos da obra lírica de Camões levados a efeito pela erudição de Hernani Cidade datam de quase 20 anos, quando em 1936, na "Revista da Faculdade de Lisboa", escreveu "LUIS DE CAMÕES" - o Lírico.

  8. Application of diagnostics to determine operational readiness of aged motor-operated valves

    International Nuclear Information System (INIS)

    Eissenberg, D.M.

    1987-01-01

    Oak Ridge National Laboratory (ORNL) has been carrying out an aging assessment of motor-operated valves (MOVs) with the primary objective of recommending diagnostic methods for detecting and trending aging. As a result of experimental investigations at ORNL, it was discovered that the motor current during a valve stroke was a very useful diagnostic parameter for detecting and trending many MOV drive train load variations. The motor current signatures were analyzed at four levels: mean value for a stroke, gross trends during a stroke, transients, and noise frequency spectra. Examples illustrating the use of this technique are presented. The use of motor current signature analysis was also shown to apply to other electric motor driven equipment. Future work includes developing a data base of MOV diagnostics, including criteria for determining the extent of degradation and application of the technique to other LWR motor driven safety equipment

  9. Simulant Development for Hanford Tank Farms Double Valve Isolation (DVI) Valves Testing

    Energy Technology Data Exchange (ETDEWEB)

    Wells, Beric E.

    2012-12-21

    Leakage testing of a representative sample of the safety-significant isolation valves for Double Valve Isolation (DVI) in an environment that simulates the abrasive characteristics of the Hanford Tank Farms Waste Transfer System during waste feed delivery to the Waste Treatment and Immobilization Plant (WTP) is to be conducted. The testing will consist of periodic leak performed on the DVI valves after prescribed numbers of valve cycles (open and close) in a simulated environment representative of the abrasive properties of the waste and the Waste Transfer System. The valve operations include exposure to cycling conditions that include gravity drain and flush operation following slurry transfer. The simulant test will establish the performance characteristics and verify compliance with the Documented Safety Analysis. Proper simulant development is essential to ensure that the critical process streams characteristics are represented, National Research Council report “Advice on the Department of Energy's Cleanup Technology Roadmap: Gaps and Bridges”

  10. Stent valve implantation in conventional redo aortic valve surgery to prevent patient-prosthesis mismatch.

    Science.gov (United States)

    Ferrari, Enrico; Franciosi, Giorgio; Clivio, Sara; Faletra, Francesco; Moccetti, Marco; Moccetti, Tiziano; Pedrazzini, Giovanni; Demertzis, Stefanos

    2017-03-01

    The goal was to show the technical details, feasibility and clinical results of balloon-expandable stent valve implantation in the aortic position during conventional redo open-heart surgery in selected obese patients with a small aortic prosthesis and severe patient-prosthesis mismatch. Two symptomatic overweight patients (body mass index of 31 and 38), each with a small aortic prosthesis (a 4-year-old, 21-mm Hancock II biological valve and a 29-year-old, 23-mm Duromedic mechanical valve), increased transvalvular gradients (59/31 and 74/44 mmHg) and a reduced indexed effective orifice area (0.50 and 0.43 cm 2 /m 2 ) underwent implantation of two 26-mm balloon-expandable Sapien 3 valves during standard on-pump redo valve surgery. Using full re-sternotomy, cardiopulmonary bypass and cardioplegic arrest, the two balloon-expandable stent valves were implanted under direct view using a standard aortotomy, after prosthesis removal and without annulus enlargement. Aortic cross-clamp times were 162 and 126 min; cardiopulmonary bypass times were 178 and 180 min; total surgical times were 360 and 318 min. At discharge, echocardiograms showed transvalvular peak and mean gradients of 13/9 and 23/13 mmHg and indexed effective orifice areas of 0.64 and 1.08 cm 2 /m 2 . The 3-month echocardiographic follow-up showed transvalvular peak and mean gradients of 18/9 and 19/11 mmHg and indexed effective orifice areas of 0.78 cm 2 /m 2 and 0.84 cm 2 /m 2 , with improved symptoms (New York Heart Association class 1). Implantation of a balloon-expandable stent valve during redo aortic valve surgery is feasible in selected cases and prevents patient-prosthesis mismatch in obese patients without need for aortic annulus enlargement. Moreover, in the case of stent valve degeneration, this approach permits additional valve-in-valve procedures with large stent valves and prevents re-redo surgery. © The Author 2016. Published by Oxford University Press on behalf of the

  11. Cyclonic valve test: preliminary results

    Energy Technology Data Exchange (ETDEWEB)

    Monteiro, Andre Sampaio; Moraes, Carlos Alberto C.; Marins, Luiz Philipe M.; Soares, Fabricio; Oliveira, Dennis; Lima, Fabio Soares de; Airao, Vinicius [Petroleo Brasileiro S.A. (PETROBRAS), Rio de Janeiro, RJ (Brazil); Ton, Tijmen [Twister BV, Rijswijk (Netherlands)

    2012-07-01

    For many years, the petroleum industry has been developing a valve that input less shear to the flow for a given required pressure drop and this can be done using the cyclonic concept. This paper presents a comparison between the performances of a cyclonic valve (low shear) and a conventional globe valve. The aim of this work is to show the advantages of using a cyclonic low shear valve instead of the commonly used in the primary separation process by PETROBRAS. Tests were performed at PETROBRAS Experimental Center (NUEX) in Aracaju/SE varying some parameters: water cut; pressure loss (from 4 kgf/cm2 to 10 kgf/cm2); flow rates (30 m3/h and 45 m3/h). Results indicates a better performance of the cyclonic valve, if compared with a conventional one, and also that the difference of the performance, is a function of several parameters (emulsion stability, water content free, and oil properties). The cyclonic valve tested can be applied as a choke valve, as a valve between separation stages (for pressure drop), or for controlling the level of vessels. We must emphasize the importance to avoid the high shear imposed by conventional valves, because once the emulsion is created, it becomes more difficult to break it. New tests are being planned to occur in 2012, but PETROBRAS is also analyzing real cases where the applications could increase the primary process efficiency. In the same way, the future installations are also being designed considering the cyclonic valve usage. (author)

  12. Bioprinting a cardiac valve.

    Science.gov (United States)

    Jana, Soumen; Lerman, Amir

    2015-12-01

    Heart valve tissue engineering could be a possible solution for the limitations of mechanical and biological prostheses, which are commonly used for heart valve replacement. In tissue engineering, cells are seeded into a 3-dimensional platform, termed the scaffold, to make the engineered tissue construct. However, mimicking the mechanical and spatial heterogeneity of a heart valve structure in a fabricated scaffold with uniform cell distribution is daunting when approached conventionally. Bioprinting is an emerging technique that can produce biological products containing matrix and cells, together or separately with morphological, structural and mechanical diversity. This advance increases the possibility of fabricating the structure of a heart valve in vitro and using it as a functional tissue construct for implantation. This review describes the use of bioprinting technology in heart valve tissue engineering. Copyright © 2015 Elsevier Inc. All rights reserved.

  13. The role of complementary and alternative medicine (CAM in Germany – A focus group study of GPs

    Directory of Open Access Journals (Sweden)

    Rosemann Thomas

    2008-06-01

    Full Text Available Abstract Background There has been a marked increase in the use of complementary and alternative medicine (CAM in recent years worldwide. In Germany, apart from 'Heilpraktiker' (= state-licensed, non-medical CAM practitioners, some general practitioners (GPs provide CAM in their practices. This paper aims to explore the attitudes of GPs about the role of CAM in Germany, in relation to the healthcare system, quality of care, medical education and research. Furthermore, experiences of GPs integrating CAM in their daily practice were explored. Methods Using a qualitative methodological approach 3 focus groups with a convenience sample of 17 GPs were conducted. The discussions were transcribed verbatim and analysed using qualitative content analysis. Results The majority of the participating GPs had integrated one or more CAM therapies into their every-day practice. Four key themes were identified based on the topics covered in the focus groups: the role of CAM within the German healthcare system, quality of care, education and research. Within the theme 'role of CAM within the healthcare system' there were five categories: integration of CAM, CAM in the Statutory Health Insurance, modernisation of the Statutory Health Insurance Act, individual healthcare services and 'Heilpraktiker'. Regarding quality of care there were two broad groups of GPs: those who thought patients would benefit from standardizing CAM and those who feared that quality control would interfere with the individual approach of CAM. The main issues identified relating to research and education were the need for the development of alternative research strategies and the low quality of existing CAM education respectively. Conclusion The majority of the participating GPs considered CAM as a reasonable complementary approach within primary care. The study increased our understanding of GPs attitudes about the role of CAM within the German healthcare system and the use of

  14. CAD/CAM-assisted breast reconstruction

    International Nuclear Information System (INIS)

    Melchels, Ferry; Hutmacher, Dietmar Werner; Wiggenhauser, Paul Severin; Schantz, Jan-Thorsten; Warne, David; Barry, Mark; Ong, Fook Rhu; Chong, Woon Shin

    2011-01-01

    The application of computer-aided design and manufacturing (CAD/CAM) techniques in the clinic is growing slowly but steadily. The ability to build patient-specific models based on medical imaging data offers major potential. In this work we report on the feasibility of employing laser scanning with CAD/CAM techniques to aid in breast reconstruction. A patient was imaged with laser scanning, an economical and facile method for creating an accurate digital representation of the breasts and surrounding tissues. The obtained model was used to fabricate a customized mould that was employed as an intra-operative aid for the surgeon performing autologous tissue reconstruction of the breast removed due to cancer. Furthermore, a solid breast model was derived from the imaged data and digitally processed for the fabrication of customized scaffolds for breast tissue engineering. To this end, a novel generic algorithm for creating porosity within a solid model was developed, using a finite element model as intermediate.

  15. Cam Femoroacetabular Impingement as a Possible Explanation of Recalcitrant Anterior Knee Pain.

    Science.gov (United States)

    Sanchis-Alfonso, Vicente; Tey, Marc; Monllau, Joan Carles

    2016-01-01

    We present a case of a patient with chronic anterior knee pain (AKP) recalcitrant to conservative treatment who returned to our office for severe hip pain secondary to Cam femoroacetabular impingement (Cam FAI) at 10 months after the onset of knee pain. This case highlights the fact that the main problem is not in the patella but in the hip in some patients with AKP. We hypothesize that there is an external femoral rotation in order to avoid the impingement and therefore the hip pain in patients with Cam FAI. This functional femoral rotation could provoke a patellofemoral imbalance that may be, in theory, responsible for patellofemoral pain in this particular patient. In our case, Cam FAI resolution was related to the resolution of AKP.

  16. Diseases of the Tricuspid Valve

    Science.gov (United States)

    ... stenosis. Tricuspid Regurgitation Tricuspid regurgitation is also called tricuspid insufficiency or tricuspid incompetence. It means there is a ... require valve surgery. Tags: heart valves , tricuspid incompetence , ... tricuspid regurgitation , tricuspid stenosis , valve disease Related Links ...

  17. Optimal results of aortic valve replacement with small mechanical valves (< 19 mm).

    Science.gov (United States)

    Kato, Yasuyuki; Hattori, Koji; Motoki, Manabu; Takahashi, Yosuke; Kotani, Shinsuke; Nishimura, Shinsuke; Shibata, Toshihiko

    2013-07-01

    Controversy exists regarding the optimal operative method or type of prosthesis for patients with a small aortic root. The aim of this retrospective study was to investigate the early and mid-term outcomes of standard aortic valve replacement (AVR) using 16 mm or 18 mm ATS Advanced Performance (AP) or 17 mm St. Jude Medical (SJM) Regent valves for a small aortic root. Between April 2003 and August 2009, 78 patients (age range: 50-86 years; 86% aged > or = 65 years) underwent AVR with 16 mm or 18 mm ATS AP valves (16AP group: n = 21, 18AP group: n = 32), or a 17 mm SJM Regent valve (17Regent group: n = 25). Fifty-six patients (72%) had a body surface area (BSA) of regression was similar among the groups (-30%, -25% and -28% in the 16AP, 17Regent and 18AP groups, respectively; p = 0.844). The early and mid-term results of AVR with 16 mm or 18 mm ATS AP valves, or with a 17 mm SJM Regent valve, were satisfactory. Therefore, standard AVR using these small mechanical prostheses, which avoids the need to enlarge the annulus or to conduct stentless bioprosthesis implantation, might represent an acceptable method, especially in elderly patients with a small aortic root.

  18. Fabricating Complete Dentures with CAD/CAM and RP Technologies.

    Science.gov (United States)

    Bilgin, Mehmet Selim; Erdem, Ali; Aglarci, Osman Sami; Dilber, Erhan

    2015-06-01

    Two techological approaches for fabricating dentures; computer-aided design and computer-aided manufacturing (CAD/CAM) and rapid prototyping (RP), are combined with the conventional techniques of impression and jaw relation recording to determine their feasibility and applicability. Maxillary and mandibular edentulous jaw models were produced using silicone molds. After obtaining a gypsum working model, acrylic bases were crafted, and occlusal rims for each model were fabricated with previously determined standard vertical and centric relationships. The maxillary and mandibular relationships were recorded with guides. The occlusal rims were then scanned with a digital scanner. The alignment of the maxillary and mandibular teeth was verified. The teeth in each arch were fabricated in one piece, or set, either by CAM or RP. Conventional waxing and flasking was then performed for both methods. These techniques obviate a practitioner's need for technicians during design and provide the patient with an opportunity to participate in esthetic design with the dentist. In addition, CAD/CAM and RP reduce chair time; however, the materials and techniques need further improvements. Both CAD/CAM and RP techniques seem promising for reducing chair time and allowing the patient to participate in esthetics design. Furthermore, the one-set aligned artificial tooth design may increase the acrylic's durability. © 2015 by the American College of Prosthodontists.

  19. Epigenetic regulation of L1CAM in endometrial carcinoma: comparison to cancer–testis (CT-X) antigens

    International Nuclear Information System (INIS)

    Schirmer, Uwe; Fiegl, Heidi; Pfeifer, Marco; Zeimet, Alain G; Müller-Holzner, Elisabeth; Bode, Peter K; Tischler, Verena; Altevogt, Peter

    2013-01-01

    L1CAM was originally identified as an adhesion molecule involved in neural development. In many human carcinomas L1CAM is over-expressed and is associated with a bad prognosis. We previously reported that L1CAM was absent in the vast majority of endometrioid endometrial carcinomas (ECs) (type 1) but was strongly expressed in the more aggressive serous and clear-cell ECs (termed type 2). The differential regulation of L1CAM in ECs is not well understood. Recent evidence suggests that it can be regulated by epigenetic mechanisms. Here we investigated the role of DNA-methylation of the L1CAM promoter for expression. We also studied the relationship to cancer testis (CT-X) antigens that co-localize with L1CAM on chromosome Xq28, a region that is often activated in human tumors. We used EC cell lines and primary tumor tissues for our analysis. For expression analysis we employed RT-PCR and Western blotting. DNA-Methylation of the L1CAM promoter was determined after bisulfite conversation and DNA sequencing. Tumor tissues were examined by immunohistochemical (IHC) staining. We demonstrate that the treatment of L1CAM low/negative expressing EC cell lines with 5 ′ -Azacytidine (5-AzaC) or knock-down of DNMT1 (DNA methyltransferase 1) as well as the HDAC (histone deacetylase) inhibitor Trichostatin A (TSA) up-regulated L1CAM at the mRNA and protein level. The L1CAM gene has two promoter regions with two distinct CpG islands. We observed that the expression of L1CAM correlated with hypermethylation in promoter 1 and 5-AzaC treatment affected the DNA-methylation pattern in this region. The CT-X antigens NY-ESO-1, MAGE-A3 and MAGE-A4 were also strongly up-regulated by 5-AzaC or knock-down of DNMT1 but did not respond to treatment with TSA. Primary EC tumor tissues showed a variable methylation pattern of the L1CAM promoter. No striking differences in promoter methylation were observed between tumor areas with L1CAM expression and those without expression. L1CAM expression

  20. Transcatheter mitral valve repair in osteogenesis imperfecta associated mitral valve regurgitation.

    Science.gov (United States)

    van der Kley, Frank; Delgado, Victoria; Ajmone Marsan, Nina; Schalij, Martin J

    2014-08-01

    Osteogenesis imperfecta is associated with increased prevalence of significant mitral valve regurgitation. Surgical mitral valve repair and replacement are feasible but are associated with increased risk of bleeding and dehiscence of implanted valves may occur more frequently. The present case report describes the outcomes of transcatheter mitral valve repair in a patient with osteogenesis imperfecta. A 60 year-old patient with osteogenesis imperfecta and associated symptomatic moderate to severe mitral regurgitation underwent transthoracic echocardiography which showed a nondilated left ventricle with preserved systolic function and moderate to severe mitral regurgitation. On transoesophageal echocardiography the regurgitant jet originated between the anterolateral scallops of the anterior and posterior leaflets (A1-P1). Considering the comorbidities associated with osteogenesis imperfecta the patient was accepted for transcatheter mitral valve repair using the Mitraclip device (Abbott vascular, Menlo, CA). Under fluoroscopy and 3D transoesophageal echocardiography guidance, a Mitraclip device was implanted between the anterolateral and central scallops with significant reduction of mitral regurgitation. The postoperative evolution was uneventful. At one month follow-up, transthoracic echocardiography showed a stable position of the Mitraclip device with no mitral regurgitation. Transcatheter mitral valve repair is feasible and safe in patients with osteogenesis imperfecta and associated symptomatic significant mitral regurgitation. Copyright © 2014 Australian and New Zealand Society of Cardiac and Thoracic Surgeons (ANZSCTS) and the Cardiac Society of Australia and New Zealand (CSANZ). Published by Elsevier B.V. All rights reserved.

  1. Complementing a Rural Pharmacy Course with CAM: Reflections from a Decade of Experience

    Directory of Open Access Journals (Sweden)

    Maree Simpson

    2014-03-01

    Full Text Available Substantial complementary medicines (CAM use is reported worldwide. Australian consumers use CAM for health maintenance, minor self-limiting disease states, and also for chronic conditions. The increasing use of CAM has required pharmacists to become increasingly more knowledgeable about CAM and the ethics of CAM recommendation. When the first Australian non-metropolitan pharmacy program was started at Charles Sturt University, in 1997, it was decided to incorporate two innovative courses to assist rurally educated students to engage with health consumers who expect pharmacists to be able to assist them with CAM. This discussion traces and reflects on the development, implementation and current situation of the Complementary Medicines for Pharmacy course. Over time, this course has evolved from a final year elective with a focus on familiarization to a mandated course with a phytomedicine focus to an integrated topic in final year with a focus on evidence, quality of evidence and professional decision-making demonstrated in a reflective professional portfolio. Of potentially greater importance, however, has been the introduction of complementary medicines as a topic in every year of the course with the goal of facilitating effective professional engagement with health consumers.

  2. Development of an effective valve packing program

    Energy Technology Data Exchange (ETDEWEB)

    Hart, K.A.

    1996-12-01

    Current data now shows that graphite valve packing installed within the guidance of a controlled program produces not only reliable stem sealing but predictable running loads. By utilizing recent technological developments in valve performance monitoring for both MOV`s and AOV`s, valve packing performance can be enhanced while reducing maintenance costs. Once known, values are established for acceptable valve packing loads, the measurement of actual valve running loads via the current MOV/AOV diagnostic techniques can provide indication of future valve stem sealing problems, improper valve packing installation or identify the opportunity for valve packing program improvements. At times the full benefit of these advances in material and predictive technology remain under utilized due to simple past misconceptions associated with valve packing. This paper will explore the basis for these misconceptions, provide general insight into the current understanding of valve packing and demonstrate how with this new understanding and current valve diagnostic equipment the key aspects required to develop an effective, quality valve packing program fit together. The cost and operational benefits provided by this approach can be significant impact by the: elimination of periodic valve repacking, reduction of maintenance costs, benefits of leak-free valve operation, justification for reduced Post Maintenance Test Requirements, reduced radiation exposure, improved plant appearance.

  3. Inverse spin-valve effect in nanoscale Si-based spin-valve devices

    Science.gov (United States)

    Hiep, Duong Dinh; Tanaka, Masaaki; Hai, Pham Nam

    2017-12-01

    We investigated the spin-valve effect in nano-scale silicon (Si)-based spin-valve devices using a Fe/MgO/Ge spin injector/detector deposited on Si by molecular beam epitaxy. For a device with a 20 nm Si channel, we observed clear magnetoresistance up to 3% at low temperature when a magnetic field was applied in the film plane along the Si channel transport direction. A large spin-dependent output voltage of 20 mV was observed at a bias voltage of 0.9 V at 15 K, which is among the highest values in lateral spin-valve devices reported so far. Furthermore, we observed that the sign of the spin-valve effect is reversed at low temperatures, suggesting the possibility of a spin-blockade effect of defect states in the MgO/Ge tunneling barrier.

  4. Evaluation of mechanical and optical behavior of current esthetic dental restorative CAD/CAM composites.

    Science.gov (United States)

    Stawarczyk, Bogna; Liebermann, Anja; Eichberger, Marlis; Güth, Jan-Frederik

    2015-03-01

    To determine the mechanical and optical properties of CAD/CAM composites (LAVA Ultimate, Cerasmart, Shofu Block and two exp. CAD/CAM composites), a hybrid material (VITA Enamic), a leucite (IPS Empress CAD) and a lithium disilicate glass-ceramic (IPS e.max CAD). Three-point flexural strength (FS) was investigated according ISO 6872:2008 (N=240/n=30). Two-body wear (TBW) was analyzed in a chewing simulator (1,200,000 cycles, 50N, 5°/55°C) using human teeth as antagonists (N=120/n=15). Quantitative analysis of wear was carried out with a 3D-scanner and associated matching software. Discoloration rate (DR) after 14 days of storage in cress, curry, red wine, and distilled water (N=384/n=12), and translucency (T) (N=384/n=48) of CAD/CAM materials were measured in a spectrophotometer (400-700nm wavelength). Data were analyzed using two-/one-way ANOVA with Scheffé post-hoc test, Kruskal-Wallis-H test, and linear mixed models (α=0.05). IPS e.max CAD showed the highest FS (pCAD/CAM composites (exception: Shofu Block). The lowest FS showed VITA Enamic and IPS Empress CAD (pCAD, VITA Enamic, exp. CAD/CAM composite 2, followed by IPS e.max presented lower material TBW than the remaining CAD/CAM materials (pcurry>cress>distilled water) exerted the highest influence on DR (pCAD/CAM material. Glass-ceramics showed lower DR than CAD/CAM composites (pCAD/CAM composites presented moderate FS, high T and antagonist friendly behavior. Glass-ceramic demonstrated the most favorable DR and lowest TBW on the material side. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. The Pleiotropic Role of L1CAM in Tumor Vasculature

    Directory of Open Access Journals (Sweden)

    Francesca Angiolini

    2017-01-01

    Full Text Available Angiogenesis, the formation of new vessels, is a key step in the development, invasion, and dissemination of solid tumors and, therefore, represents a viable target in the context of antitumor therapy. Indeed, antiangiogenic approaches have given promising results in preclinical models and entered the clinical practice. However, in patients, the results obtained so far with antiangiogenic drugs have not completely fulfilled expectations, especially because their effect has been transient with tumors developing resistance and evasion mechanisms. A better understanding of the mechanisms that underlie tumor vascularization and the functional regulation of cancer vessels is a prerequisite for the development of novel and alternative antiangiogenic treatments. The L1 cell adhesion molecule (L1CAM, a cell surface glycoprotein previously implicated in the development and plasticity of the nervous system, is aberrantly expressed in the vasculature of various cancer types. L1CAM plays multiple pro-angiogenic roles in the endothelial cells of tumor-associated vessels, thus emerging as a potential therapeutic target. In addition, L1CAM prevents the maturation of cancer vasculature and its inhibition promotes vessel normalization, a process that is thought to improve the therapeutic response of tumors to cytotoxic drugs. We here provide an overview on tumor angiogenesis and antiangiogenic therapies and summarize the current knowledge on the biological role of L1CAM in cancer vasculature. Finally, we highlight the clinical implications of targeting L1CAM as a novel antiangiogenic and vessel-normalizing approach.

  6. Mechanical versus bioprosthetic aortic valve replacement.

    Science.gov (United States)

    Head, Stuart J; Çelik, Mevlüt; Kappetein, A Pieter

    2017-07-21

    Mechanical valves used for aortic valve replacement (AVR) continue to be associated with bleeding risks because of anticoagulation therapy, while bioprosthetic valves are at risk of structural valve deterioration requiring reoperation. This risk/benefit ratio of mechanical and bioprosthetic valves has led American and European guidelines on valvular heart disease to be consistent in recommending the use of mechanical prostheses in patients younger than 60 years of age. Despite these recommendations, the use of bioprosthetic valves has significantly increased over the last decades in all age groups. A systematic review of manuscripts applying propensity-matching or multivariable analysis to compare the usage of mechanical vs. bioprosthetic valves found either similar outcomes between the two types of valves or favourable outcomes with mechanical prostheses, particularly in younger patients. The risk/benefit ratio and choice of valves will be impacted by developments in valve designs, anticoagulation therapy, reducing the required international normalized ratio, and transcatheter and minimally invasive procedures. However, there is currently no evidence to support lowering the age threshold for implanting a bioprosthesis. Physicians in the Heart Team and patients should be cautious in pursuing more bioprosthetic valve use until its benefit is clearly proven in middle-aged patients. Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2017. For permissions, please email: journals.permissions@oup.com.

  7. Latest design of gate valves

    Energy Technology Data Exchange (ETDEWEB)

    Kurzhofer, U.; Stolte, J.; Weyand, M.

    1996-12-01

    Babcock Sempell, one of the most important valve manufacturers in Europe, has delivered valves for the nuclear power industry since the beginning of the peaceful application of nuclear power in the 1960s. The latest innovation by Babcock Sempell is a gate valve that meets all recent technical requirements of the nuclear power technology. At the moment in the United States, Germany, Sweden, and many other countries, motor-operated gate and globe valves are judged very critically. Besides the absolute control of the so-called {open_quotes}trip failure,{close_quotes} the integrity of all valve parts submitted to operational forces must be maintained. In case of failure of the limit and torque switches, all valve designs have been tested with respect to the quality of guidance of the gate. The guidances (i.e., guides) shall avoid a tilting of the gate during the closing procedure. The gate valve newly designed by Babcock Sempell fulfills all these characteristic criteria. In addition, the valve has cobalt-free seat hardfacing, the suitability of which has been proven by friction tests as well as full-scale blowdown tests at the GAP of Siemens in Karlstein, West Germany. Babcock Sempell was to deliver more than 30 gate valves of this type for 5 Swedish nuclear power stations by autumn 1995. In the presentation, the author will report on the testing performed, qualifications, and sizing criteria which led to the new technical design.

  8. Thermal fatigue behavior of valves

    International Nuclear Information System (INIS)

    Moinereau, D.; Scliffet, L.; Capion, J.C.; Genette, P.

    1991-01-01

    This paper reports that valves of pressurized water reactors are exposed to thermal shocks during transient operations. The numerous thermal shock tests performed on valves on the EDF test facilities have shown the sensibility of fillets and geometrical discontinuities to thermal fatigue: cracks can appear in those areas and grow through the valve body. Valves systems designated as level 1 must be designed to withstand fatigue up to the second isolation valve: the relevant rule is specified in the paragraph B 3500 of the French RCCM code. It is a simplified method which doesn't require finite element calculations. Many valve systems have been designed according to this rule and have been operated without accident. However, in one case, important cracks were found in the fillet of a check-valve after numerous thermal shocks. Calculation of the valve's behavior according to the RCCM code to estimate the fatigue damage resulting from thermal shocks led to a low damage factor, which doesn't agree with the experimental results. This was confirmed by new testings and showed the inadequacy of B 3500 rule for thermal transients. On this base a new rule is proposed to estimate fatigue damage resulting from thermal shocks. An experimental program has been realized to validate this rule. Axisymetrical analytical mock-ups with different geometries and one check-valve in austenitic stainless steel 316 L have been submitted to hot thermal shocks of 210 degrees C magnitude

  9. EpCAM as multi-tumour target for near-infrared fluorescence guided surgery

    International Nuclear Information System (INIS)

    Driel, P. B. A. A. van; Boonstra, M. C.; Prevoo, H. A. J. M.; Giessen, M. van de; Snoeks, T. J. A.; Tummers, Q. R. J. G.; Keereweer, S.; Cordfunke, R. A.; Fish, A.; Eendenburg, J. D. H. van; Lelieveldt, B. P. F.; Dijkstra, J.; Velde, C. J. H. van de; Kuppen, P. J. K.; Vahrmeijer, A. L.; Löwik, C. W. G. M.; Sier, C. F. M.

    2016-01-01

    Evaluation of resection margins during cancer surgery can be challenging, often resulting in incomplete tumour removal. Fluorescence-guided surgery (FGS) aims to aid the surgeon to visualize tumours and resection margins during surgery. FGS relies on a clinically applicable imaging system in combination with a specific tumour-targeting contrast agent. In this study EpCAM (epithelial cell adhesion molecule) is evaluated as target for FGS in combination with the novel Artemis imaging system. The NIR fluorophore IRDye800CW was conjugated to the well-established EpCAM specific monoclonal antibody 323/A3 and an isotype IgG1 as control. The anti-EpCAM/800CW conjugate was stable in serum and showed preserved binding capacity as evaluated on EpCAM positive and negative cell lines, using flow cytometry and cell-based plate assays. Four clinically relevant orthotopic tumour models, i.e. colorectal cancer, breast cancer, head and neck cancer, and peritonitis carcinomatosa, were used to evaluate the performance of the anti-EpCAM agent with the clinically validated Artemis imaging system. The Pearl Impulse small animal imaging system was used as reference. The specificity of the NIRF signal was confirmed using bioluminescence imaging and green-fluorescent protein. All tumour types could clearly be delineated and resected 72 h after injection of the imaging agent. Using NIRF imaging millimetre sized tumour nodules were detected that were invisible for the naked eye. Fluorescence microscopy demonstrated the distribution and tumour specificity of the anti-EpCAM agent. This study shows the potential of an EpCAM specific NIR-fluorescent agent in combination with a clinically validated intraoperative imaging system to visualize various tumours during surgery

  10. Surge-damping vacuum valve

    International Nuclear Information System (INIS)

    Bullock, J.C.; Kelley, B.E.

    1977-01-01

    A valve for damping out flow surges in a vacuum system is described. The surge-damping mechanism consists of a slotted, spring-loaded disk adjacent to the valve's vacuum port (the flow passage to the vacuum roughing pump). Under flow surge conditions, the differential pressure forces the disk into a sealing engagement with the vacuum port, thereby restricting the gas flow path to narrow slots in the disk's periphery. The increased flow damps out the flow surge. When pressure is equalized on both sides of the valve, the spring load moves the disk away from the port to restore full flow conductance through the valve

  11. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study.

    Science.gov (United States)

    Lenders, Guy D; Collas, Valérie; Hernandez, José Maria; Legrand, Victor; Danenberg, Haim D; den Heijer, Peter; Rodrigus, Inez E; Paelinck, Bernard P; Vrints, Christiaan J; Bosmans, Johan M

    2014-10-20

    Transcatheter Aortic Valve Implantation (TAVI) is now considered an indispensable treatment strategy in high operative risk patients with severe, symptomatic aortic stenosis. However, conduction disturbances and the need for Permanent Pacemaker (PPM) implantation after TAVI with the CoreValve prosthesis still remain frequent. We aimed to evaluate the implantation depth, the incidence and predictors of new conduction disturbances, and the need for PPM implantation within the first month after TAVI, using the new Accutrak CoreValve delivery system (ACV), compared to the previous generation CoreValve (non-ACV). In 5 experienced TAVI-centers, a total of 120 consecutive non-ACV and 112 consecutive ACV patients were included (n=232). The mean depth of valve implantation (DVI) was 8.4±4.0 mm in the non-ACV group and 7.1±4.0 mm in the ACV group (p=0.034). The combined incidence of new PPM implantation and new LBBB was 71.2% in the non-ACV group compared to 50.5% in the ACV group (p=0.014). DVI (p=0.002), first degree AV block (p=0.018) and RBBB (p<0.001) were independent predictors of PPM implantation. DVI (p<0.001) and pre-existing first degree AV-block (p=0.021) were identified as significant predictors of new LBBB. DVI is an independent predictor of TAVI-related conduction disturbances and can be reduced by using the newer CoreValve Accutrak delivery system, resulting in a significantly lower incidence of new LBBB and new PPM implantation. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  12. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  13. Animal Models of Calcific Aortic Valve Disease

    Directory of Open Access Journals (Sweden)

    Krista L. Sider

    2011-01-01

    Full Text Available Calcific aortic valve disease (CAVD, once thought to be a degenerative disease, is now recognized to be an active pathobiological process, with chronic inflammation emerging as a predominant, and possibly driving, factor. However, many details of the pathobiological mechanisms of CAVD remain to be described, and new approaches to treat CAVD need to be identified. Animal models are emerging as vital tools to this end, facilitated by the advent of new models and improved understanding of the utility of existing models. In this paper, we summarize and critically appraise current small and large animal models of CAVD, discuss the utility of animal models for priority CAVD research areas, and provide recommendations for future animal model studies of CAVD.

  14. Disclosure of Complementary and Alternative Medicine to Conventional Medical Providers: Variation by Race/Ethnicity and Type of CAM

    Science.gov (United States)

    Chao, Maria T.; Wade, Christine; Kronenberg, Fredi

    2009-01-01

    Background Complementary and alternative medicine (CAM) is often used alongside conventional medical care, yet fewer than half of patients disclose CAM use to medical doctors. CAM disclosure is particularly low among racial/ethnic minorities, but reasons for differences, such as type of CAM used or quality of conventional healthcare, have not been explored. Objective We tested the hypotheses that disclosure of CAM use to medical doctors is higher for provider-based CAM and among non-Hispanic whites, and that access to and quality of conventional medical care account for racial/ethnic differences in CAM disclosure. Methods Bivariate and multiple variable analyses of the 2002 National Health Interview Survey and 2001 Health Care Quality Survey were performed. Results Disclosure of CAM use to medical providers was higher for provider-based than self-care CAM. Disclosure of any CAM was associated with access to and quality of conventional care and higher among non-Latino whites relative to minorities. Having a regular doctor and quality patient–provider relationship mitigated racial/ethnic differences in CAM disclosure. Conclusion Insufficient disclosure of CAM use to conventional providers, particularly for self-care practices and among minority populations, represents a serious challenge in medical encounter communications. Efforts to improve disclosure of CAM use should be aimed at improving consistency of care and patient–physician communication across racial/ethnic groups. PMID:19024232

  15. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    Abramson, R.; Elie, X.; Vercasson, M.; Nedelec, J.

    1974-01-01

    Conventionally, valves for sodium pipes smaller than 125 mm in diameter are called ''small sodium valves''. However, this limit should rather be considered as the lower limit o ''large sodium valves''. In fact, both the largest sizes of small valves and the smallest of large valves can be found in the range of 125-300 mm in diameter. Thus what is said about small valves also applies, for a few valve types, above the 125 mm limit. Sodium valves are described here in a general manner, with no manufacturing details except when necessary for understanding valve behavior. Operating experience is pointed out wherever possible. Finally, some information is given about ongoing or proposed development plans. (U.S.)

  16. Effects of competition on induction of crassulacean acid metabolism in a facultative CAM plant.

    Science.gov (United States)

    Yu, Kailiang; D'Odorico, Paolo; Li, Wei; He, Yongli

    2017-06-01

    Abiotic drivers of environmental stress have been found to induce CAM expression (nocturnal carboxylation) in facultative CAM species such as Mesembryanthemum crystallinum. The role played by biotic factors such as competition with non-CAM species in affecting CAM expression, however, remains largely understudied. This research investigated the effects of salt and water conditions on the competition between M. crystallinum and the C 3 grass Bromus mollis with which it is found to coexist in California's coastal grasslands. We also investigated the extent to which CAM expression in M. crystallinum was affected by the intensity of the competition with B. mollis. We found that M. crystallinum had a competitive advantage over B. mollis in drought and saline conditions, while B. mollis exerted strong competitive effects on M. crystallinum in access to light and soil nutrients in high water conditions. This strong competitive effect even outweighed the favorable effects of salt or water additions in increasing the biomass and productivity of M. crystallinum in mixture. Regardless of salt conditions, M. crystallinum did not switch to CAM photosynthesis in response to this strong competitive effect from B. mollis. Disturbance (i.e., grass cutting) reduced the competitive pressure by B. mollis and allowed for CAM expression in M. crystallinum when it was grown mixed with B. mollis. We suggest that moderate competition with other functional groups can enhance CAM expression in M. crystallinum, thereby affecting its plasticity and ability to cope with biological stress.

  17. Griswold Tempered Water Flow Regulator Valves Used as Anti-Siphon Valves

    International Nuclear Information System (INIS)

    MISKA, C.

    2000-01-01

    FCV-1*22 and 1*23 are Griswold constant flow regulators used as anti-siphon valves in the tempered water system, they fail closed but valve cartridge orifice allows minimum flow to prevent loss of water from the MCO/CASK annulus

  18. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  19. Experimental substantiation of the design of a prosthetic heart valve for «valve-in-valve» implantation

    Directory of Open Access Journals (Sweden)

    K. Yu. Klyshnikov

    2017-01-01

    Full Text Available The aim of the study was to perform a series of in vitro tests of a prototype of the developing heart valve prosthesis to evaluate its functional characteristics. Materials and methods. In this work we have used the frames and full prototypes of the prosthesis, consisting of a stent-like stainless steel support frame with mounted biological leaflets and cover. The authors evaluated the calculated and experimental forces necessary for the displacement of the sutureless implanted prosthesis using the test machine under uniaxial tension. The risk of defects and damages to the supporting framework as a result of implantation was evaluated by scanning electron microscopy. The hydrodynamic characteristics of the prosthesis were investigated under physiological conditions and «valvein-valve» implantation. Evaluation of the ergonomics and applicability of the proposed construction on the cadaver heart model of cattle was carried out. Results. As a result of the forces assessment, it was found that the force required to shear the prosthesis was 3.12 ± 0.37 N, while the calculated value was 1.7 N, which is significantly lower than the obtained value. The comparison of the images obtained with small and large magnifications demonstrated the absence of critical surface defects. Additional analysis under the super-large magnifications also did not reveal problem areas. During the hydrodynamic study, it was shown that the average transplant gradient increased slightly from 2.8–3.4 to 3.2–4.5 mm Hg for the initial prosthesis and the «valve-in-valve» complex, respectively. The decrease of the effective orifice area was 6–9% relative to the initial one. Evaluation of the implantation technique demonstrated the consistency of the approach: the use of the developed holder in combination with the balloon implantation system made it possible to position the prosthesis throughout the procedure. Conclusion. The series of tests demonstrates the consistency

  20. Cam Femoroacetabular Impingement as a Possible Explanation of Recalcitrant Anterior Knee Pain

    Directory of Open Access Journals (Sweden)

    Vicente Sanchis-Alfonso

    2016-01-01

    Full Text Available We present a case of a patient with chronic anterior knee pain (AKP recalcitrant to conservative treatment who returned to our office for severe hip pain secondary to Cam femoroacetabular impingement (Cam FAI at 10 months after the onset of knee pain. This case highlights the fact that the main problem is not in the patella but in the hip in some patients with AKP. We hypothesize that there is an external femoral rotation in order to avoid the impingement and therefore the hip pain in patients with Cam FAI. This functional femoral rotation could provoke a patellofemoral imbalance that may be, in theory, responsible for patellofemoral pain in this particular patient. In our case, Cam FAI resolution was related to the resolution of AKP.

  1. Valve-sparing aortic root replacement†

    NARCIS (Netherlands)

    Koolbergen, David R.; Manshanden, Johan S. J.; Bouma, Berto J.; Blom, Nico A.; Mulder, Barbara J. M.; de Mol, Bas A. J. M.; Hazekamp, Mark G.

    2015-01-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed.

  2. Mitral valve-sparing procedures and prosthetic heart valve failure: A case report

    Science.gov (United States)

    Khan, Nasir A; Butany, Jagdish; Leong, Shaun W; Rao, Vivek; Cusimano, Robert J; Ross, Heather J

    2009-01-01

    Prosthetic heart valve dysfunction due to thrombus or pannus formation can be a life-threatening complication. The present report describes a 47-year-old woman who developed valvular cardiomyopathy after chorda-sparing mitral valve replacement, and subsequently underwent heart transplantation for progressive heart failure. The explanted mitral valve prosthesis showed significant thrombus and pannus leading to reduced leaflet mobility and valvular stenosis. The present report illustrates the role of the subvalvular apparatus and pannus in prosthesis dysfunction. PMID:19279993

  3. Astrocyte-specific disruption of SynCAM1 signaling results in ADHD-like behavioral manifestations.

    Directory of Open Access Journals (Sweden)

    Ursula S Sandau

    Full Text Available SynCAM1 is an adhesion molecule involved in synaptic differentiation and organization. SynCAM1 is also expressed in astroglial cells where it mediates astrocyte-to astrocyte and glial-neuronal adhesive communication. In astrocytes, SynCAM1 is functionally linked to erbB4 receptors, which are involved in the control of both neuronal/glial development and mature neuronal and glial function. Here we report that mice carrying a dominant-negative form of SynCAM1 specifically targeted to astrocytes (termed GFAP-DNSynCAM1 mice exhibit disrupted diurnal locomotor activity with enhanced and more frequent episodes of activity than control littermates during the day (when the animals are normally sleeping accompanied by shorter periods of rest. GFAP-DNSynCAM1 mice also display high levels of basal activity in the dark period (the rodent's awake/active time that are attenuated by the psychostimulant D,L-amphetamine, and reduced anxiety levels in response to both avoidable and unavoidable provoking stimuli. These results indicate that disruption of SynCAM1-dependent astroglial function results in behavioral abnormalities similar to those described in animals model of attention-deficit hyperactive disorder (ADHD, and suggest a hitherto unappreciated contribution of glial cells to the pathophysiology of this disorder.

  4. Analysis of aortic root surgery with composite mechanical aortic valve conduit and valve-sparing reconstruction.

    Science.gov (United States)

    Dias, Ricardo Ribeiro; Mejia, Omar Asdrubal Vilca; Fiorelli, Alfredo Inácio; Pomerantzeff, Pablo Maria Alberto; Dias, Altamiro Ribeiro; Mady, Charles; Stolf, Noedir Antonio Groppo

    2010-01-01

    Comparative analysis of early and late results of aortic root reconstruction with aortic valve sparing operations and the composite mechanical valve conduit replacement. From November 2002 to September 2009, 164 consecutive patients with mean age 54 ± 15 years, 115 male, underwent the aortic root reconstruction (125 mechanical valve conduit replacements and 39 valve sparing operations). Sixteen percent of patients had Marfan syndrome and 4.3% had bicuspid aortic valve. One hundred and forty-four patients (88%) were followed for a mean period of 41.1 ± 20.8 months. The hospital mortality was 4.9%, 5.6% in operations with valved conduits and 2.6% in the valve sparing procedures (P valve sparing operations, respectively (95% CI = 70% - 95%, P = 0.001), (95% CI = 82% - 95% P = 0.03) and (95% CI = 81% - 95%, P = 0.03). Multivariate analysis showed that creatinine greater than 1.4 mg/dl, Cabrol operation and renal dialysis were predictors of mortality, respectively, with occurrence chance of 6 (95% CI = 1.8 - 19.5, P = 0.003), 12 (95% CI = 3 - 49.7, P = 0.0004) and 16 (95% CI = 3.6 - 71.3, P = 0.0002). The aortic root reconstruction has a low early and late mortality, high survival free of complications and low need for reoperation. During the late follow-up, valve sparing aortic root reconstructions presented fewer incidences of bleeding, thromboembolic events and endocarditis.

  5. Simple Check Valves for Microfluidic Devices

    Science.gov (United States)

    Willis, Peter A.; Greer, Harold F.; Smith, J. Anthony

    2010-01-01

    A simple design concept for check valves has been adopted for microfluidic devices that consist mostly of (1) deformable fluorocarbon polymer membranes sandwiched between (2) borosilicate float glass wafers into which channels, valve seats, and holes have been etched. The first microfluidic devices in which these check valves are intended to be used are micro-capillary electrophoresis (microCE) devices undergoing development for use on Mars in detecting compounds indicative of life. In this application, it will be necessary to store some liquid samples in reservoirs in the devices for subsequent laboratory analysis, and check valves are needed to prevent cross-contamination of the samples. The simple check-valve design concept is also applicable to other microfluidic devices and to fluidic devices in general. These check valves are simplified microscopic versions of conventional rubber- flap check valves that are parts of numerous industrial and consumer products. These check valves are fabricated, not as separate components, but as integral parts of microfluidic devices. A check valve according to this concept consists of suitably shaped portions of a deformable membrane and the two glass wafers between which the membrane is sandwiched (see figure). The valve flap is formed by making an approximately semicircular cut in the membrane. The flap is centered over a hole in the lower glass wafer, through which hole the liquid in question is intended to flow upward into a wider hole, channel, or reservoir in the upper glass wafer. The radius of the cut exceeds the radius of the hole by an amount large enough to prevent settling of the flap into the hole. As in a conventional rubber-flap check valve, back pressure in the liquid pushes the flap against the valve seat (in this case, the valve seat is the adjacent surface of the lower glass wafer), thereby forming a seal that prevents backflow.

  6. Aortic Regurgitation in Patients Undergoing Transcatheter Aortic Valve Replacement With the Self-Expanding CoreValve Versus the Balloon-Expandable SAPIEN XT Valve.

    Science.gov (United States)

    Kiramijyan, Sarkis; Magalhaes, Marco A; Koifman, Edward; Didier, Romain; Escarcega, Ricardo O; Baker, Nevin C; Negi, Smita I; Minha, Sa'ar; Torguson, Rebecca; Jiaxiang, Gai; Asch, Federico M; Wang, Zuyue; Okubagzi, Petros; Gaglia, Michael A; Ben-Dor, Itsik; Satler, Lowell F; Pichard, Augusto D; Waksman, Ron

    2016-05-01

    The incidence of aortic regurgitation (AR) after transcatheter aortic valve replacement (TAVR) in a self-expanding and a balloon-expandable system is controversial. This study aimed to examine the incidence and severity of post-TAVR AR with the CoreValve (CV) versus the Edwards XT Valve (XT). Baseline, procedural, and postprocedural inhospital outcomes were compared. The primary end point was the incidence of post-TAVR AR of any severity, assessed with a transthoracic echocardiogram, in the CV versus XT groups. A multivariate logistic regression analysis was completed to evaluate for correlates of the primary end point. The secondary end points included the change in severity of AR at 30-day and 1-year follow-up. A total of 223 consecutive patients (53% men, mean age 82 years) who had transfemoral TAVR with either a CV (n = 119) or XT (n = 104) were evaluated. The rates of post-TAVR AR in the groups were similar, and there was no evidence of more-than-moderate AR in either group. There were significant differences in the rates of intraprocedural balloon postdilation with the CV (17.1%) versus XT valve (5.8%; p = 0.009) and in the rates of intraprocedural implantation of a second valve-in-valve prosthesis with the CV (9.9%) versus XT valve (2.2%; p = 0.036). There were no significant differences in inhospital safety outcomes between the 2 groups. In conclusion, the incidence of post-TAVR AR is similar between the CV and the XT valve when performed by experienced operators using optimal intraprocedural strategies, as deemed appropriate, to mitigate the severity of AR. Copyright © 2016 Elsevier Inc. All rights reserved.

  7. Pannus Formation Leads to Valve Malfunction in the Tricuspid Position 19 Years after Triple Valve Replacement.

    Science.gov (United States)

    Alskaf, Ebraham; McConkey, Hannah; Laskar, Nabila; Kardos, Attila

    2016-06-20

    The Medtronic ATS Open Pivot mechanical valve has been successfully used in heart valve surgery for more than two decades. We present the case of a patient who, 19 years following a tricuspid valve replacement with an ATS prosthesis as part of a triple valve operation following infective endocarditis, developed severe tricuspid regurgitation due to pannus formation.

  8. Recurrent pannus formation causing prosthetic aortic valve dysfunction: is excision without valve re-replacement applicable?

    Science.gov (United States)

    Darwazah, Ahmad K

    2012-06-29

    Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function.The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement.A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve.Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  9. Valve-sparing aortic root replacement†.

    Science.gov (United States)

    Koolbergen, David R; Manshanden, Johan S J; Bouma, Berto J; Blom, Nico A; Mulder, Barbara J M; de Mol, Bas A J M; Hazekamp, Mark G

    2015-02-01

    To evaluate our results of valve-sparing aortic root replacement and associated (multiple) valve repair. From September 2003 to September 2013, 97 patients had valve-sparing aortic root replacement procedures. Patient records and preoperative, postoperative and recent echocardiograms were reviewed. Median age was 40.3 (range: 13.4-68.6) years and 67 (69.1%) were male. Seven (7.2%) patients were younger than 18 years, the youngest being 13.4 years. Fifty-four (55.7%) had Marfan syndrome, 2 (2.1%) other fibrous tissue diseases, 15 (15.5%) bicuspid aortic valve and 3 (3.1%) had earlier Fallot repair. The reimplantation technique was used in all, with a straight vascular prosthesis in 11 (26-34 mm) and the Valsalva prosthesis in 86 (26-32 mm). Concomitant aortic valve repair was performed in 43 (44.3%), mitral valve repair in 10 (10.3%), tricuspid valve repair in 5 (5.2%) and aortic arch replacement in 3 (3.1%). Mean follow-up was 4.2 ± 2.4 years. Follow-up was complete in all. One 14-year old patient died 1.3 years post-surgery presumably of ventricular arrhythmia. One patient underwent reoperation for aneurysm of the proximal right coronary artery after 4.9 years and 4 patients required aortic valve replacement, 3 of which because of endocarditis after 0.1, 0.8 and 1.3 years and 1 because of cusp prolapse after 3.8 years. No thrombo-embolic complications occurred. Mortality, root reoperation and aortic regurgitation were absent in 88.0 ± 0.5% at 5-year follow-up. Results of valve-sparing root replacement are good, even in association with a high incidence of concomitant valve repair. Valve-sparing aortic root replacement can be performed at a very young age as long as an adult size prosthesis can be implanted. © The Author 2014. Published by Oxford University Press on behalf of the European Association for Cardio-Thoracic Surgery. All rights reserved.

  10. Engineering task plan for rotary mode core sampling exhausters CAM high radiation interlock

    International Nuclear Information System (INIS)

    BOGER, R.M.

    1999-01-01

    The Rotary Mode Core Sampling (RMCS) system is primarily made up of the Rotary Mode Core Sample Trucks (RMCST) and the RMCS Exhausters. During RMCS operations an Exhauster is connected to a tank riser and withdraws gases from the tank dome vapor space at approximately 200 Standard Cubic Feet per Minute (SCFM). The gases are passed through two High Efficiency Particulate Air (HEPA) filters before passing out the exhaust stack to the atmosphere. A Continuous Air Monitor (CAM) monitors the exhaust gases in the exhaust stack for beta particle and gamma radiation. The CAM has a high radiation alarm output and a detector fail alarm output. The CAM alarms are currently connected to the data logger only. The CAM alarms require operator response per procedure LMHC 1998 but no automatic functions are initiated by the CAM alarms. Currently, there are three events that can cause an automatic shut down of the Exhauster. These are, Low Tank Pressure, Highnow Stack Flow and High HEPA Filter Differential Pressure (DP)

  11. Axial computed tomography evaluation of the internal nasal valve correlates with clinical valve narrowing and patient complaint.

    Science.gov (United States)

    Moche, Jason A; Cohen, Justin C; Pearlman, Steven J

    2013-07-01

    The objective of this work was to explore the utility of axial computed tomography (CT) imaging to objectively define a narrow internal nasal valve, and compare those findings with clinical examination and patient complaint. Retrospective review from a single facial plastic surgery center. We reviewed 40 consecutive patients evaluated for either sinusitis or nasal airway obstruction for which a CT scan was obtained at a single radiology institution. Thirty-six complete office records were examined for the presence of clinical internal valve narrowing and complaints of nasal obstruction. In total, 72 internal nasal valves were analyzed using axial plane CT and measurements were compared to clinical findings and presence of airway obstruction. Measured valve areas for clinically normal internal nasal valves averaged 0.47 cm(2) vs 0.28 cm(2) for clinically narrow valves, a decrease of 40.4%. In unobstructed nasal airways the valve area averaged 0.51 cm(2) vs 0.38 cm(2) in obstructed airways, a difference of 25.5%. A radiographically measured valve area of <0.30 cm(2) suggests clinical narrowing with a sensitivity of 71.4%, specificity of 88.9%, positive predictive value of 62.5%, and negative predictive value of 92.3%. Using standard axial CT imaging we describe an objective method of radiographically evaluating the nasal valve, demonstrating strong correlation with physical examination and patient complaint. Additionally, radiographic valve areas can be used to screen for clinically narrow nasal valves with good sensitivity and specificity, providing a novel straightforward method for nasal valve assessment. © 2012 ARS-AAOA, LLC.

  12. Small sodium valve design and operating experience

    International Nuclear Information System (INIS)

    McGough, C.B.

    1974-01-01

    The United States Liquid Metal Fast Breeder Reactor program (LMFBR) includes an extensive program devoted to the development of small sodium valves. This program is now focused on the development and production of valves for the Fast Flux Test Facility (FFTF) now under construction near Richland, Washington. Other AEC support facilities, such as various test loops located at the Liquid Metal Engineering Center (LMEC), Los Angeles, California, and at the Hanford Engineering Development Laboratory (HEDL), Richland, Washington, also have significant requirements for small sodium valves, and valves similar in design to the FFTF valves are being supplied to these AEC laboratories for use in their critical test installations. A principal motivation for these valve programs, beyond the immediate need to provide high-reliability valves for FFTF and the support facilities, is the necessity to develop small valve technology for the Clinch River Breeder Reactor Plant (CRBRP). FFTF small sodium valve design and development experience will be directly applied to the CRBRP program. Various test programs have been, and are being, conducted to verify the performance and integrity of the FFTF valves, and to uncover any potential problems so that they can be corrected before the valves are placed in service in FFTF. The principal small sodium valve designs being utilized in current U.S. programs, the test and operational experience obtained to date on them, problems uncovered, and future development and testing efforts being planned are reviewed. The standards and requirements to which the valves are being designed and fabricated, the valve designs in current use, valve operators, test and operating experience, and future valve development plans are summarized. (U.S.)

  13. Comparison of EyeCam and anterior segment optical coherence tomography in detecting angle closure.

    Science.gov (United States)

    Baskaran, Mani; Aung, Tin; Friedman, David S; Tun, Tin A; Perera, Shamira A

    2012-12-01

    To compare the diagnostic performance of EyeCam (Clarity Medical Systems, Pleasanton, CA, USA) and anterior segment optical coherence tomography (ASOCT, Visante; Carl Zeiss Meditec, Dublin, CA, USA) in detecting angle closure, using gonioscopy as the reference standard. Ninety-eight phakic patients, recruited from a glaucoma clinic, underwent gonioscopy by a single examiner, and EyeCam and ASOCT imaging by another examiner. Another observer, masked to gonioscopy findings, graded EyeCam and ASOCT images. For both gonioscopy and EyeCam, a closed angle in a particular quadrant was defined if the posterior trabecular meshwork was not visible. For ASOCT, angle closure was defined by any contact between the iris and angle anterior to the scleral spur. An eye was diagnosed as having angle closure if ≥2 quadrants were closed. Agreement and area under the receiver operating characteristic curves (AUC) were evaluated. The majority of subjects were Chinese (69/98, 70.4%) with a mean age of 60.6 years. Angle closure was diagnosed in 39/98 (39.8%) eyes with gonioscopy, 40/98 (40.8%) with EyeCam and 56/97 (57.7%) with ASOCT. The agreement (kappa statistic) for angle closure diagnosis for gonioscopy versus EyeCam was 0.89; gonioscopy versus ASOCT and EyeCam versus ASOCT were both 0.56. The AUC for detecting eyes with gonioscopic angle closure with EyeCam was 0.978 (95% CI: 0.93-1.0) and 0.847 (95% CI: 0.76-0.92, p < 0.01) for ASOCT. The diagnostic performance of EyeCam was better than ASOCT in detecting angle closure when gonioscopic grading was used as the reference standard. The agreement between the two imaging modalities was moderate. © 2012 The Authors. Acta Ophthalmologica © 2012 Acta Ophthalmologica Scandinavica Foundation.

  14. Developments in mechanical heart valve prosthesis

    Indian Academy of Sciences (India)

    Artificial heart valves are engineered devices used for replacing diseased or damaged natural valves of the heart. Most commonly used for replacement are mechanical heart valves and biological valves. This paper briefly outlines the evolution, designs employed, materials being used,. and important factors that affect the ...

  15. Ball check valve

    International Nuclear Information System (INIS)

    Bevilacqua, F.

    1978-01-01

    A pressurized nuclear reactor having an instrument assembly sheathed in a metallic tube which is extended vertically upward into the reactor core by traversing a metallic guide tube which is welded to the wall of the vessel is described. Sensors in each instrument assembly are connected to instruments outside the vessel to manifest the conditions within the core. Each instrument assembly probe is moved into position within a metallic guide channel. The guide channel penetrates the wall of the vessel and forms part of the barrier to the environment within the pressure vessel. Each channel includes a ball check valve which is opened by the instrument assembly probe when the probe passes through the valve. A ball valve element is moved from its seat by the probe to a position lateral of the bore of the channel and is guided to its seat along a sloped path within the valve body when the probe is removed. 5 claims, 3 figures

  16. Three-Dimensional Digital Evaluation of the Fit of Endocrowns Fabricated from Different CAD/CAM Materials.

    Science.gov (United States)

    Zimmermann, Moritz; Valcanaia, Andre; Neiva, Gisele; Mehl, Albert; Fasbinder, Dennis

    2018-03-06

    A wide variety of CAD/CAM materials are available for single-tooth restorations. CAD/CAM material characteristics are different and may influence CAM fabrication accuracy. There is no study investigating the influence of different CAD/CAM materials on the final fit of the restoration. The aim of this study was to evaluate the fit of endocrowns fabricated from different CAD/CAM materials using a new 3D evaluation method with an intraoral scanning system. The null hypothesis was that there are no significant differences for the fitting accuracy of different CAD/CAM materials. Preparation for an endocrown was performed on a maxillary right first molar on a typodont, and restorations were fabricated with a chairside CAD/CAM system (CEREC Omnicam, MCXL). Three groups using three different CAD/CAM materials were established (each n = 10): zirconia-reinforced lithium silicate ceramic (Celtra Duo; CD), leucite-reinforced silicate ceramic (Empress CAD; EM), resin nanoceramic (Lava Ultimate; LU). A 3D digital measurement technique (OraCheck, Cyfex AG) using an intraoral scanner (CEREC Omnicam) was used to measure the difference in fit between the three materials for a master endocrown preparation. The preparation scan and the endocrown fit scan were matched with special difference analysis software OraCheck. Three areas were selected for fitting accuracy measurements: margin (MA), axial (AX), occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and post-hoc Scheffé test. Significance level was set to p = 0.05. Results varied from best 88.9 ± 7.7 μm for marginal fit of resin nanoceramic restorations (LU_MA) to worst 182.3 ± 24.0 μm for occlusal fit of zirconia-reinforced lithium silicate restorations (CD_OC). Statistically significant differences were found both within and among the test groups. Group CD performed statistically significantly different from group LU for marginal fit (MA) and axial fit (AX) (p 0.05). Deviation pattern for

  17. CAM and Post-Traumatic Stress Disorder

    Directory of Open Access Journals (Sweden)

    Alex Hankey

    2007-01-01

    Full Text Available In the form of the Transcendental Meditation program CAM offers a method of eliminating deep-rooted stress, the efficacy of which has been demonstrated in several related studies. Any discussion of CAM and post-traumatic stress disorder should include a study of its application to Vietnam War Veterans in which improvements were observed on all variables, and several participants were able to return to work after several years of being unable to hold a job. The intervention has been studied for its impact on brain and autonomic nervous system function. It has been found to be highly effective against other stress-related conditions such as hypertension, and to improve brain coherence—a measure of effective brain function. It should be considered a possible ‘new and improved mode of treatment’ for PTSD, and further studies of its application made.

  18. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  19. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  20. Cavitation guide for control valves

    Energy Technology Data Exchange (ETDEWEB)

    Tullis, J.P. [Tullis Engineering Consultants, Logan, UT (United States)

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation.

  1. Cavitation guide for control valves

    International Nuclear Information System (INIS)

    Tullis, J.P.

    1993-04-01

    This guide teaches the basic fundamentals of cavitation to provide the reader with an understanding of what causes cavitation, when it occurs, and the potential problems cavitation can cause to a valve and piping system. The document provides guidelines for understanding how to reduce the cavitation and/or select control valves for a cavitating system. The guide provides a method for predicting the cavitation intensity of control valves, and how the effect of cavitation on a system will vary with valve type, valve function, valve size, operating pressure, duration of operation and details of the piping installation. The guide defines six cavitation limits identifying cavitation intensities ranging from inception to the maximum intensity possible. The intensity of the cavitation at each limit Is described, including a brief discussion of how each level of cavitation influences the valve and system. Examples are included to demonstrate how to apply the method, including making both size and pressure scale effects corrections. Methods of controlling cavitation are discussed providing information on various techniques which can be used to design a new system or modify an existing one so it can operate at a desired level of cavitation

  2. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  3. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease

    NARCIS (Netherlands)

    Yap, Sing-Chien; Drenthen, Willem; Pieper, Petronella G.; Moons, Philip; Mulder, Barbara J. M.; Klieverik, Loes M.; Vliegen, Hubert W.; van Dijk, Arie P. J.; Meijboom, Folkert J.; Roos-Hesselink, Jolien W.

    2007-01-01

    Background and aim of the study: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  4. Outcome of pregnancy in women after pulmonary autograft valve replacement for congenital aortic valve disease.

    NARCIS (Netherlands)

    Yap, S.C.; Drenthen, W.; Pieper, P.G.; Moons, P.; Mulder, B.J.M.; Klieverik, L.M.; Vliegen, H.W.; Dijk, A.P.J. van; Meijboom, F.J.; Roos-Hesselink, J.W.

    2007-01-01

    BACKGROUND AND AIM OF THE STUDY: The pulmonary autograft has been recommended as the valve of choice for aortic valve replacement (AVR) in young women contemplating pregnancy. However, current information on maternal and perinatal outcome of pregnancy in women with pulmonary autograft valve

  5. Recurrent pannus formation causing prosthetic aortic valve dysfunction: Is excision without valve re-replacement applicable?

    Directory of Open Access Journals (Sweden)

    Darwazah Ahmad K

    2012-06-01

    Full Text Available Abstract Prosthetic valve dysfunction at aortic position is commonly caused by pannus formation. The exact etiology is not known. It arises from ventricular aspect of the prosthesis encroaching its leaflets causing stenosis or it may remain localized causing left ventricular outflow tract obstruction without affecting valve function. The difference in location entails different approaches in management. Such a pathology requires surgical excision of the pannus with or without valve re-replacement. A recurrent pannus was observed in a female patient who needed repeated surgical intervention to excise a localized pannus without re-replacement of a well functioning prosthetic valve. Management of our case presents several questions, whether recurrence of pannus is caused by sparing the prosthetic valve, is it simply an exaggeration of an inflammatory healing process in certain individuals or is it ideal to re-replace the valve despite a well preserved function.

  6. Camões e Garret: navegações do Restelo a Cascais

    Directory of Open Access Journals (Sweden)

    Paulo Motta Oliveira

    1999-10-01

    Full Text Available Esse ensaio pretende analisar a presença de Luís de Camões, em especialdo Camões épico, em algumas das principais obras de Almeida Garrett, mostrando que essa presença faz uma navegação que partindo de Restelo chega a Cascais.

  7. Butterfly valve of all rubber lining type

    International Nuclear Information System (INIS)

    Shimada, Shosaku; Nakatsuma, Sumiya; Sasaki, Iwao; Aoki, Naoshi.

    1982-01-01

    The valves used for the circulating water pipes for condensers in nuclear and thermal power stations have become large with the increase of power output, and their specifications have become strict. The materials for the valves change from cast iron to steel plate construction. To cope with sea water corrosion, rubber lining has been applied to the internal surfaces of valve boxes, and the build-up welding of stainless steel has been made on the edges of valves. However, recently it is desired to develop butterfly valves, of which the whole valve disks are lined with hard rubber. For the purpose of confirming the performance of large bore valves, a 2600 mm bore butterfly valve of all rubber lining type was used, and the opening and closing test of 1100 times was carried out by applying thermal cycle and pressure difference and using artifical sea water. Also the bending test of hard rubber lining was performed with test pieces. Thus, it was confirmed that the butterfly valves of all rubber lining type have the performance exceeding that of the valves with build-up welding. The course of development of the valves of all rubber lining type, the construction and the items of confirmation by tests of these valves, and the tests of the valve and the hard rubber lining described above are reported. (Kako, I.)

  8. Marginal and internal fit of nano-composite CAD/CAM restorations

    Directory of Open Access Journals (Sweden)

    So-Hyun Park

    2016-02-01

    Full Text Available Objectives The purpose of this study was to compare the marginal and internal fit of nano-composite CAD-CAM restorations. Materials and Methods A full veneer crown and an mesio-occluso-distal (MOD inlay cavity, which were prepared on extracted human molars, were used as templates of epoxy resin replicas. The prepared teeth were scanned and CAD-CAM restorations were milled using Lava Ultimate (LU and experimental nano-composite CAD/CAM blocks (EB under the same milling parameters. To assess the marginal and internal fit, the restorations were cemented to replicas and were embedded in an acrylic mold for sectioning at 0.5 mm intervals. The measured gap data were pooled according to the block types and measuring points for statistical analysis. Results Both the block type and measuring point significantly affected gap values, and their interaction was significant (p = 0.000. In crowns and inlays made from the two blocks, gap values were significantly larger in the occlusal area than in the axial area, while gap values in the marginal area were smallest (p < 0.001. Among the blocks, the restorations milled from EB had a significantly larger gap at all measuring points than those milled from LU (p = 0.000. Conclusions The marginal and internal gaps of the two nano-composite CAD/CAM blocks differed according to the measuring points. Among the internal area of the two nano-composite CAD/CAM restorations, occlusal gap data were significantly larger than axial gap data. The EB crowns and inlays had significantly larger gaps than LU restorations.

  9. A STUDY OF INDICATIONS, COMPLICATIONS OF PROSTHETIC VALVES AND PROGNOSIS AFTER TREATMENT OF STUCK VALVE

    Directory of Open Access Journals (Sweden)

    Y. V. Subba Reddy

    2017-03-01

    Full Text Available BACKGROUND Implantation of prosthetic cardiac valves to treat haemodynamically significant valvular diseases has become common; however, it is associated with complications. Thus, this study was intended to evaluate the indications for implantation of prosthetic valve and complications after its implantation and prognosis after treatment of one of its complication, i.e. stuck valve. MATERIALS AND METHODS This was a single-centered study wherein 50 patients who came to the emergency department with stuck valve were assessed. The 2D echocardiography was performed in all patients. Thrombolysis was done and the gradients were reassessed. Further response to treatment and development of complications before and after treatment were observed. RESULTS Of total patients, 60% were females. Mean age group was 30-40 yrs. Most of them were asymptomatic for 6 years and there was lack of compliance in 90% of patients. Most common indication for valve replacement was mitral stenosis (60% followed by mitral regurgitation (20%, aortic regurgitation and aortic stenosis (10% and combined mitral and tricuspid regurgitation (10%. Commonest valve was St. Jude (90%. Pannus was observed in 10% patients and thrombus was observed in 50% patients. Most patients had gradients 45/20 mmHg across mitral valve. In about 90% patients, gradients decreased after thrombolysis (12/5 mmHg. The complications after thrombolysis were hemiparesis (4%, death before thrombolysis (6% and death after thrombolysis (4%. CONCLUSION Considering these results, it can be concluded that prosthetic valves are seldom associated with some complications. Further, thrombolysis can be effective in patients with prosthetic valve thrombosis.

  10. Supra-annular Valve-in-Valve implantation reduces blood stasis on the transcatheter aortic valve leaflets.

    Science.gov (United States)

    Vahidkhah, Koohyar; Azadani, Ali N

    2017-06-14

    Leaflet thrombosis following transcatheter aortic valve replacement (TAVR) and Valve-in-Valve (ViV) procedures has been increasingly recognized. This study aimed to investigate the effect of positioning of the transcatheter aortic valve (TAV) in ViV setting on the flow dynamics aspect of post-ViV thrombosis by quantifying the blood stasis in the intra-annular and supra-annular settings. To that end, two idealized computational models, representing ViV intra-annular and supra-annular positioning of a TAV were developed in a patient-specific geometry. Three-dimensional flow fields were then obtained via fluid-solid interaction modeling to study the difference in blood residence time (BRT) on the TAV leaflets in the two settings. At the end of diastole, a strip of high BRT (⩾1.2s) region was observed on the TAV leaflets in the ViV intra-annular positioning at the fixed boundary where the leaflets are attached to the frame. Such a high BRT region was absent on the TAV leaflets in the supra-annular positioning. The maximum value of BRT on the surface of non-, right, and left coronary leaflets of the TAV in the supra-annular positioning were 53%, 11%, and 27% smaller compared to the intra-annular positioning, respectively. It was concluded that the geometric confinement of TAV by the leaflets of the failed bioprosthetic valve in ViV intra-annular positioning increases the BRT on the leaflets and may act as a permissive factor in valvular thrombosis. The absence of such a geometric confinement in the ViV supra-annular positioning leads to smaller BRT and subsequently less likelihood of leaflet thrombosis. Copyright © 2017 Elsevier Ltd. All rights reserved.

  11. Resurgery for recurrent heart valve diseases

    Directory of Open Access Journals (Sweden)

    Chong-lei REN

    2017-02-01

    Full Text Available Objective To summarize the experience with resurgery for recurrent valvular heart diseases. Methods From June 2004 to June 2015, 28 patients (15 males and 13 females with ages ranging from 44 to 67 years (55.6±6.5 years with recurrent heart valve disease underwent resurgery. The reasons for resurgery included perivalvular leakage (7 cases, bioprosthetic valve decline (6 cases in mitral valve and 3 in tricuspid valve, mechanical prostheses dysfunction (2cases, infective endocarditis after valve replacement (2 cases, restenosis of repaired native valve (1 case, and severe tricuspid insufficiency after left-side valve surgery (7 cases. Resurgery included mitral valve replacement in 18 patients and tricuspid valve replacement in 10. All the patients underwent third or fourth or even fifth cardiac surgery for valve replacement. Results There were 2 hospital deaths with a mortality of 7.1% (2/28. The main causes of early-stage deaths were low cardiac output syndrome. The main postoperative complications were respiratory failure in 3, low cardiac output syndrome in 2, reexploration for bleeding in 2 and serious infectious shock in 1. All the patients were found with the great improvement in heart function and the re-implanted prostheses worked well during follow-up. Conclusions Although resurgery for recurrent heart valve disease poses a continuing challenge to cardiac surgeon, it could be performed with the satisfactory results. The keys to a successful cardiac resurgery include appropriate operational timing, refined surgical technique and reasonable perioperative managements. DOI: 10.11855/j.issn.0577-7402.2017.01.11

  12. CAM: A Collaborative Object Memory System

    NARCIS (Netherlands)

    Vyas, Dhaval; Nijholt, Antinus; Kröner, Alexander

    2010-01-01

    Physical design objects such as sketches, drawings, collages, storyboards and models play an important role in supporting communication and coordination in design studios. CAM (Cooperative Artefact Memory) is a mobile-tagging based messaging system that allows designers to collaboratively store

  13. miR-21-3p is a positive regulator of L1CAM in several human carcinomas.

    Science.gov (United States)

    Doberstein, Kai; Bretz, Niko P; Schirmer, Uwe; Fiegl, Heidi; Blaheta, Roman; Breunig, Christian; Müller-Holzner, Elisabeth; Reimer, Dan; Zeimet, Alain G; Altevogt, Peter

    2014-11-28

    Expression of L1 cell adhesion molecule (L1CAM) occurs frequently in human cancers and is associated with poor prognosis in cancers such as ovarian, endometrial, breast, renal cell carcinoma and pancreatic ductal adenocarcinoma. L1CAM promotes cell motility, invasion, chemoresistance and metastasis formation. Elucidating genetic processes involved in the expression of L1CAM in cancers is of considerable importance. Transcription factors such as SLUG, β-catenin/TCF-LEF, PAX8 and VHL have been implicated in the re-activation of L1CAM in various types of cancers. There is increasing evidence that micro-RNAs can also have strong effects on gene expression. Here we have identified miR-21-3p as a positive regulator of L1CAM expression. Over-expression of miR-21-3p (miR-21*) but not the complementary sequence miR-21-5p (miR-21) could strongly augment L1CAM expression in renal, endometrial and ovarian carcinoma derived cell lines by an unknown mechanism involving transcriptional activation of the L1CAM gene. In patient cohorts from renal, endometrial and ovarian cancers we observed a strong positive correlation of L1CAM and miR-21-3p expressions. Although L1CAM alone was a reliable marker for overall and disease free survival, the combination of L1CAM and miR-21-3p expressions strongly enhanced the predictive power. Our findings shed new light on the complex regulation of L1CAM in cancers and advocate the use of L1CAM/miR-21-3p for diagnostic application. Copyright © 2014 Elsevier Ireland Ltd. All rights reserved.

  14. Valve-stem-packing improvement study. Final report

    International Nuclear Information System (INIS)

    Adey, C.W.; Klein, J.J.

    1982-08-01

    By employing questionnaires and face-to-face interviews with valve and valve packing manufacturers, as well as nuclear plant personnel, an understanding of valve stem packing leakage problems from each of the three viewpoints was developed. This information, in-house experience, and available technical literature were used to develop specific recommendations for valve manufacturers, valve packing manufacturers, and nuclear plant valve users. It was generally recommended that each these groups make better use of graphite packing. The questionnaires and interviews indicated that increased usage of graphite packing over the last few years has reduced the incidence of valve packing problems. To confirm this, a survey of Licensee Event Reports (LERs) from 1972 to 1980 was undertaken using the keywords Valve and Packing. A statistical analysis of the LER data confirms that the adoption of graphite packing has significantly reduced valve stem leakage

  15. Double-reed exhaust valve engine

    Science.gov (United States)

    Bennett, Charles L.

    2015-06-30

    An engine based on a reciprocating piston engine that extracts work from pressurized working fluid. The engine includes a double reed outlet valve for controlling the flow of low-pressure working fluid out of the engine. The double reed provides a stronger force resisting closure of the outlet valve than the force tending to open the outlet valve. The double reed valve enables engine operation at relatively higher torque and lower efficiency at low speed, with lower torque, but higher efficiency at high speed.

  16. Effect of degradative plasmid CAM-OCT on responses of Pseudomonas bacteria to UV light

    International Nuclear Information System (INIS)

    McBeth, D.L.

    1989-01-01

    The effect of plasmid CAM-OCT on responses to UV irradiation was compared in Pseudomonas aeruginosa, in Pseudomonas putida, and in Pseudomonas putida mutants carrying mutations in UV response genes. CAM-OCT substantially increased both survival and mutagenesis in the two species. P. aeruginosa strains without CAM-OCT exhibited much higher UV sensitivity than did P. putida strains. UV-induced mutagenesis of plasmid-free P. putida was easily detected in three different assays (two reversion assays and one forward mutation assay), whereas UV mutagenesis of P. aeruginosa without CAM-OCT was seen only in the forward mutation assay. These results suggest major differences in DNA repair between the two species and highlight the presence of error-prone repair functions on CAM-OCT. A number of P. putida mutants carrying chromosomal mutations affecting either survival or mutagenesis after UV irradiation were isolated, and the effect of CAM-OCT on these mutants was determined. All mutations producing a UV-sensitive phenotype in P. putida were fully suppressed by the plasmid, whereas the plasmid had a more variable effect on mutagenesis mutations, suppressing some and producing no suppression of others. On the basis of the results reported here and results obtained by others with plasmids carrying UV response genes, it appears that CAM-OCT may differ either in regulation or in the number and functions of UV response genes encoded

  17. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  18. INTEGRASI SOFTWARE CAD-CAM DALAM SISTEM OPERASI MESIN BUBUT CNC

    Directory of Open Access Journals (Sweden)

    Yuris Setyoadi

    2015-12-01

    Full Text Available Computer Aided Manufacturing (CAM adalah sebuah teknologi aplikasi yang menggunakan perangkat lunak komputer dan mesin untuk memfasilitasi dan mengotomatisasi proses manufaktur. Computer Aided Manufacturing (CAM adalah penerus dari Computer Aided Engineering (CAE dan sering digunakan bersama dengan Computer-Aided Design (CAD. Bidang manufaktur, perangkat komputer telah dipergunakan untuk mengontrol mesin-mesin produksi otomatis dengan ketepatan tinggi, misalnya mesin CNC. ?é?áArtikel ini membahas tentang penggunaan software CAD-CAM (SOLIDWorks dan CAMWorks yang terintegrasi kemudian diaplikasikan ke mesin bubut CNC yang menggunakan software Mach3, Mach3 adalah software yang bisa mengubah komputer dekstop menjadi sebuah piranti kontroller mesin CNC. Software SOLIDWorks, CAMWorks dan Mach3 diintegrasikan ke dalam sistem operasi mesin bubut CNC sehingga proses koreksi dan modifikasi format perintah gerakan dalam G/M code dapat dilakukan dalam software tersebut.

  19. Gate valve and motor-operator research findings

    International Nuclear Information System (INIS)

    Steele, R. Jr.; DeWall, K.G.; Watkins, J.C.; Russell, M.J.; Bramwell, D.

    1995-09-01

    This report provides an update on the valve research being sponsored by the US Nuclear Regulatory Commission (NRC) and conducted at the Idaho National Engineering Laboratory (INEL). The research addresses the need to provide assurance that motor-operated valves can perform their intended safety function, usually to open or close against specified (design basis) flow and pressure loads. This report describes several important developments: Two methods for estimating or bounding the design basis stem factor (in rising-stem valves), using data from tests less severe than design basis tests; a new correlation for evaluating the opening responses of gate valves and for predicting opening requirements; an extrapolation method that uses the results of a best effort flow test to estimate the design basis closing requirements of a gate valve that exhibits atypical responses (peak force occurs before flow isolation); and the extension of the original INEL closing correlation to include low- flow and low-pressure loads. The report also includes a general approach, presented in step-by-step format, for determining operating margins for rising-stem valves (gate valves and globe valves) as well as quarter-turn valves (ball valves and butterfly valves)

  20. Valve leakage inspection testing and maintenance process

    International Nuclear Information System (INIS)

    Aikin, J.A.; Reinwald, J.W.; Kittmer, C.A.

    1991-01-01

    In valve maintenance, packing rings that prevent leakage along the valve stem must periodically be replaced, either during routine maintenance or to correct a leak or valve malfunction. Tools and procedures currently in use for valve packing removal and inspection are generally of limited value due to various access and application problems. A process has been developed by AECL Research that addresses these problems. The process, using incompressible fluid pressure, quickly and efficiently confirms the integrity of the valve backseat, extracts hard-to-remove valve packing sets, and verifies the leak tightness of the repacked valve

  1. Strut fracture of Björk-Shiley convexo-concave valve in Japan--risk of small valve size--.

    Science.gov (United States)

    Watarida, S; Shiraishi, S; Nishi, T; Imura, M; Yamamoto, Y; Hirokawa, R; Fujita, M

    2001-08-01

    The Björk-Shiley convexo-concave (BSCC) prosthetic valve was introduced in 1979. Between 1979 and 1986, approximately 86,000 BSCC valves were implanted. By December 31, 1994, 564 complete strut fractures had been reported to the manufacture. We experienced a case of an outlet strut fracture and investigated the risk of BSCC prosthetic valve fractures in Japan. To investigate the risk factor of a strut fracture in Japan, we investigated published cases of strut fractures. Between 1979 and 1986, 2021 BSCC valves were implanted in Japan. By January 31, 2000, 11 complete strut fractures of 60-degree BSCC valves including our case had occurred. The patients were eight males and three females. The average age at valve replacement was 42.4+/-8.1 years, and nine of eleven (81.8%) were patients valve fractured was 47.7+/-6.4 years, and eight of eleven (72.7%) were patients valve were 27 mm (n=5) (45.5%), 29 mm (n=3) (27.2%), and 31 mm (n=3) (27.2%). Four patients died and seven patients survived. Although only 11 BSCC valve struts fractured and statistical analysis could not be performed, our findings suggest that the high risk group for a strut fracture in Japan is young male patients with a mitral valve, >= 27 mm in size with BSCC models manufactured before March 1982. When following-up patients with BSCC models manufactured before March 1982, the possibility of a strut fracture in all BSCC valve sizes should be kept in mind.

  2. A remotely operated drug delivery system with an electrolytic pump and a thermo-responsive valve

    KAUST Repository

    Yi, Ying

    2015-07-22

    Implantable drug delivery devices are becoming attractive due to their abilities of targeted and controlled dose release. Currently, two important issues are functional lifetime and non-controlled drug diffusion. In this work, we present a drug delivery device combining an electrolytic pump and a thermo-responsive valve, which are both remotely controlled by an electromagnetic field (40.5 mT and 450 kHz). Our proposed device exhibits a novel operation mechanism for long-term therapeutic treatments using a solid drug in reservoir approach. Our device also prevents undesired drug liquid diffusions. When the electromagnetic field is on, the electrolysis-induced bubble drives the drug liquid towards the Poly (N-Isopropylacrylamide) (PNIPAM) valve that consists of PNIPAM and iron micro-particles. The heat generated by the iron micro-particles causes the PNIPAM to shrink, resulting in an open valve. When the electromagnetic field is turned off, the PNIPAM starts to swell. In the meantime, the bubbles are catalytically recombined into water, reducing the pressure inside the pumping chamber, which leads to the refilling of the fresh liquid from outside the device. A catalytic reformer is included, allowing more liquid refilling during the limited valve\\'s closing time. The amount of body liquid that refills the drug reservoir can further dissolve the solid drug, forming a reproducible drug solution for the next dose. By repeatedly turning on and off the electromagnetic field, the drug dose can be cyclically released, and the exit port of the device is effectively controlled.

  3. Edge strength of CAD/CAM materials.

    Science.gov (United States)

    Pfeilschifter, Maria; Preis, Verena; Behr, Michael; Rosentritt, Martin

    2018-05-16

    To investigate the edge force of CAD/CAM materials as a function of (a) material, (b) thickness, and (c) distance from the margin. Materials intended for processing with CAD/CAM were investigated: eight resin composites, one resin-infiltrated ceramic, and a clinically proven lithiumdisilicate ceramic (reference). To measure edge force (that is, load to failure/crack), plates (d = 1 mm) were fixed and loaded with a Vickers diamond indenter (1 mm/min, Zwick 1446) at a distance of 0.4, 0.5, 0.6, 0.7, 0.8, 0.9, and 1.0 mm from the edge. Edge force was defined as a loading force at a distance of 0.5 mm. The type of failure was determined. To investigate the influence of the thickness, all data were determined on 1-mm and 2-mm plates. To test the influence of bonding and an underlying dentin, individual 1-mm plates were bonded to a 1-mm-thick dentin-like (concerning modulus of elasticity) resin composite. For the 1-mm plates, edge force varied between 64.4 ± 24.2 N (Shofu Block HC) and 183.2 ± 63.3 N (ceramic reference), with significant (p ≤ 0.001) differences between the materials. For the 2-mm plates, values between 129.2 ± 32.5 N (Lava Ultimate) and 230.3 ± 67.5 N (Cerasmart) were found. Statistical comparison revealed no significant differences (p > 0.109) between the materials. Brilliant Crios (p = 0.023), Enamic (p = 0.000), Shofu Blocks HC (p = 0.009), and Grandio Bloc (p = 0.002) showed significantly different edge force between the 1-mm- and 2-mm-thick plates. The failure pattern was either cracking, (severe) chipping, or fracture. Material, material thickness, and distance from the edge impact the edge force of CAD/CAM materials. CAD/CAM materials should be carefully selected on the basis of their individual edge force and performance during milling. Copyright © 2018 Elsevier Ltd. All rights reserved.

  4. Transcatheter pulmonary valve replacement by hybrid approach using a novel polymeric prosthetic heart valve: proof of concept in sheep.

    Directory of Open Access Journals (Sweden)

    Ben Zhang

    Full Text Available Since 2000, transcatheter pulmonary valve replacement has steadily advanced. However, the available prosthetic valves are restricted to bioprosthesis which have defects like poor durability. Polymeric heart valve is thought as a promising alternative to bioprosthesis. In this study, we introduced a novel polymeric transcatheter pulmonary valve and evaluated its feasibility and safety in sheep by a hybrid approach.We designed a novel polymeric trileaflet transcatheter pulmonary valve with a balloon-expandable stent, and the valve leaflets were made of 0.1-mm expanded polytetrafluoroethylene (ePTFE coated with phosphorylcholine. We chose glutaraldehyde-treated bovine pericardium valves as control. Pulmonary valve stents were implanted in situ by a hybrid transapical approach in 10 healthy sheep (8 for polymeric valve and 2 for bovine pericardium valve, weighing an average of 22.5±2.0 kg. Angiography and cardiac catheter examination were performed after implantation to assess immediate valvular functionality. After 4-week follow-up, angiography, echocardiography, computed tomography, and cardiac catheter examination were used to assess early valvular function. One randomly selected sheep with polymeric valve was euthanized and the explanted valved stent was analyzed macroscopically and microscopically.Implantation was successful in 9 sheep. Angiography at implantation showed all 9 prosthetic valves demonstrated orthotopic position and normal functionality. All 9 sheep survived at 4-week follow-up. Four-week follow-up revealed no evidence of valve stent dislocation or deformation and normal valvular and cardiac functionality. The cardiac catheter examination showed the peak-peak transvalvular pressure gradient of the polymeric valves was 11.9±5.0 mmHg, while that of two bovine pericardium valves were 11 and 17 mmHg. Gross morphology demonstrated good opening and closure characteristics. No thrombus or calcification was seen macroscopically

  5. A systematic review of the traits and cognitions associated with use of and belief in complementary and alternative medicine (CAM).

    Science.gov (United States)

    Galbraith, Niall; Moss, Tim; Galbraith, Victoria; Purewal, Satvinder

    2018-08-01

    Complementary and alternative medicine (CAM) use is widespread despite the controversy over its effectiveness. Although previous reviews have examined the demographics and attitudes of CAM users, there is no existing review on the traits or cognitions which characterise either CAM users or those who believe in CAM effectiveness. The current systematic review set out to address these gaps in the literature by applying a narrative synthesis. A bibliographic search and manual searches were undertaken and key authors were contacted. Twenty-three papers were selected. The trait openness to experience was positively associated with CAM use but not CAM belief. Absorption and various types of coping were also positively associated with CAM use and belief. No other trait was reliably associated with CAM use or belief. Intuitive thinking and ontological confusions were positively associated with belief in CAM effectiveness; intuitive thinking was also positively associated with CAM use. Studies researching cognitions in CAM use/belief were mostly on non-clinical samples, whilst studies on traits and CAM use/belief were mostly on patients. The quality of studies varied but unrepresentative samples, untested outcome measures and simplistic statistical analyses were the most common flaws. Traits and cognition might be important correlates of CAM use and also of faith in CAM.

  6. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  7. Complete Dentures Fabricated with CAD/CAM Technology and a Traditional Clinical Recording Method.

    Science.gov (United States)

    Janeva, Nadica; Kovacevska, Gordana; Janev, Edvard

    2017-10-15

    The introduction of computer-aided design/computer-aided manufacturing (CAD/CAM) technology into complete denture (CD) fabrication ushered in a new era in removable prosthodontics. Commercially available CAD/CAM denture systems are expected to improve upon the disadvantages associated with conventional fabrication. The purpose of this report is to present the workflow involved in fabricating a CD with a traditional clinical recording method and CAD/CAM technology and to summarize the advantages to the dental practitioner and the patient.

  8. Search for rapid variability of 53 Cam

    International Nuclear Information System (INIS)

    Zverko, J.

    1982-01-01

    Photoelectric observations of magnetic Ap star 53 Cam made at the Skalnate Pleso Observatory in 1978 and 1979 are analyzed from the point of view of rapid variability. The observations were made with an intermediate passband filter, effective wavelength 526 nm. Besides the differences msub(53Cam)-msub(Comp), the behaviour was also investigated of the deflections for the comparison star during the observation runs. A strong correlation between the behaviour of the comparison and variable star light curve was found and the appearance differs from night to night depending on atmospheric conditions. Each observation run is analyzed in detail and it was concluded that all observed variations are only apparent and due to the variability of atmospheric extinction above the observation site. (author)

  9. Investigation on Electromagnetic Models of High-Speed Solenoid Valve for Common Rail Injector

    Directory of Open Access Journals (Sweden)

    Jianhui Zhao

    2017-01-01

    Full Text Available A novel formula easily applied with high precision is proposed in this paper to fit the B-H curve of soft magnetic materials, and it is validated by comparison with predicted and experimental results. It can accurately describe the nonlinear magnetization process and magnetic saturation characteristics of soft magnetic materials. Based on the electromagnetic transient coupling principle, an electromagnetic mathematical model of a high-speed solenoid valve (HSV is developed in Fortran language that takes the saturation phenomena of the electromagnetic force into consideration. The accuracy of the model is validated by the comparison of the simulated and experimental static electromagnetic forces. Through experiment, it is concluded that the increase of the drive current is conducive to improving the electromagnetic energy conversion efficiency of the HSV at a low drive current, but it has little effect at a high drive current. Through simulation, it is discovered that the electromagnetic energy conversion characteristics of the HSV are affected by the drive current and the total reluctance, consisting of the gap reluctance and the reluctance of the iron core and armature soft magnetic materials. These two influence factors, within the scope of the different drive currents, have different contribution rates to the electromagnetic energy conversion efficiency.

  10. Guidelines for valves in tritium service

    International Nuclear Information System (INIS)

    Weaver, W.W.

    1994-01-01

    Some undesirable practices and misapplications that caused valve-related failures are examined, and future courses of action are recommended to avoid repetition of these events. Desirable valve characteristics and practices that should be considered when selecting valves for use in tritium service are also discussed. Supporting logic for the desirability of these features is presented by discussing the mechanisms of valve degradation followed by examples of related events. Desirable valve and system features and operational actions are grouped into two categories: strongly recommended and recommended. 13 refs., 1 fig

  11. CLIC main beam quadrupole active pre-alignment based on cam movers

    CERN Document Server

    Kemppinen, J; Leuxe, R; Mainaud Durand, H; Sandomierski, J; Sosin, M

    2012-01-01

    Compact Linear Collider (CLIC) is a study for a future 48 km long linear electron-positron collider in the multi TeV range. Its target luminosity can only be reached if the main beam quadrupoles (MB quads) are actively pre-aligned within 17 µm in sliding windows of 200 m with respect to a straight reference line. In addition to the positioning requirement, the pre-alignment system has to provide a rigid support for the nano-stabilization system to ensure that the first eigenfrequency is above 100 Hz. Re-adjustment based on cam movers was chosen for detailed studies to meet the stringent pre-alignment requirements. There are four different types of MB quads in CLIC. Their lengths and masses vary so that at least two types of cam movers have to be developed. The validation of the cams with less stringent space restrictions has proceeded to a test setup in 5 degrees of freedom (DOF). Prototypes of the more demanding, smaller cams have been manufactured and they are under tests in 1 DOF. This paper describes the...

  12. A Unique Opportunity for an Intercultural Discussion on CAM and Liver Disease

    Directory of Open Access Journals (Sweden)

    Francesco Marotta

    2005-01-01

    Full Text Available The meeting of the APASL, Asian Pacific Association for the Study of the Liver, was held in December 2004, in New Delhi, India. The meeting was held under the patronage of the APASL Committee and Board of Presidents of the National Liver Association and in conjunction with the annual conference of the Indian Association for the Study of Liver (INASL. The congress was designed to have a core meeting with three parallel sessions running throughout, dedicated research workshops and intensive breakfast sessions. This report concentrates on the two sessions devoted to complementary and alternative medicine (CAM and shows the latest research in CAM for liver disease and the concerns of doctors about integrating CAM with more traditional treatments. With researchers and practitioners gathering from all over the world, it was a unique opportunity for an intercultural discussion on CAM and liver disease.

  13. PreCam: A Precursor Observational Campaign for Calibration of the Dark Energy Survey

    Energy Technology Data Exchange (ETDEWEB)

    Kuehn, K.; Kuhlmann, S.; Allam, S.; Annis, J. T.; Bailey, T.; Balbinot, E.; Bernstein, J. P.; Biesiadzinski, T.; Burke, D. L.; Butner, M.; Camargo, J. I. B.; da Costa, L. A. N.; DePoy, D.; Diehl, H. T.; Dietrich, J. P.; Estrada, J.; Fausti, A.; Gerke, B.; Guarino, V.; Head, H. H.; Kessler, R.; Lin, H.; Lorenzon, W.; Maia, M. A. G.; Maki, L.; Marshall, J.; Nord, B.; Neilsen, E.; Ogando, R. L. C.; Park, D.; Peoples, J.; Rastawicki, D.; Rheault, J. -P.; Santiago, B.; Schubnell, M.; Seitzer, P.; Smith, J. A.; Spinka, H.; Sypniewski, A.; Tarle, G.; Tucker, D. L.; Walker, A. R.; Wester, W.

    2013-04-01

    PreCam, a precursor observational campaign supporting the Dark Energy Survey (DES), is designed to produce a photometric and astrometric catalog of nearly a hundred thousand standard stars within the DES footprint, while the PreCam instrument also serves as a prototype testbed for the Dark Energy Camera's hardware and software. This catalog represents a potential 100-fold increase in Southern Hemisphere photometric standard stars, and therefore will be an important component in the calibration of the Dark Energy Survey. We provide details on the PreCam instrument's design, construction, and testing, as well as results from a subset of the 51 nights of PreCam survey observations on the University of Michigan Department of Astronomy's Curtis-Schmidt telescope at Cerro Tololo Inter-American Observatory (CTIO). We briefly describe the preliminary data processing pipeline that has been developed for PreCam data and the preliminary results of the instrument performance, as well as astrometry and photometry of a sample of stars previously included in other southern sky surveys.

  14. An analytical investigation on the valve and centrifugal pump speed control with a constant differential pressure across the valve

    International Nuclear Information System (INIS)

    Jung, B. R.; Joo, K. I.; Lee, B. J.; Baek, S. J.; Noh, T. S.

    2003-01-01

    A valve opening and centrifugal pump speed control was investigated analytically in a simple pumping system where the differential pressure across the control valve is maintained constant over the required flow range. The valve control program was derived analytically only as a function of the required flow rate to maintain the constant differential pressure across the valve. The centrifugal pump speed control program was also derived analytically for the required flow rate for the constant differential pressure across the control valve. These derivations theoretically show that the independent control is possible between the valve and pump speed in a system with a constant valve pressure drop. In addition, it was shown that a linear pump speed control is impossible in maintaining the constant valve pressure drop

  15. Initiating a Reiki or CAM program in a healthcare organization--developing a business plan.

    Science.gov (United States)

    Vitale, Anne

    2014-01-01

    Complementary and alternative medicine (CAM) services, such as Reiki, continue to be offered to consumers in many hospitals and other health care organizations. There is growing interest among nurses, doctors, and other health care providers for the integration of CAM therapies into traditional settings. Health care organizations are responding to this need but may not know how to start CAM programs. Starting a Reiki program in a health care setting must be envisioned in a business model approach. This article introduces nurses and other health care providers to the basic concepts of business plan development and important steps to follow when starting a Reiki or CAM program.

  16. Robust Non-Chattering Observer Based Sliding Control Concept for Electro-Hydraulic Drives

    DEFF Research Database (Denmark)

    Schmidt, Lasse; Andersen, Torben Ole; Pedersen, Henrik C.

    2013-01-01

    This paper presents an observer-based sliding mode control concept with chattering reduction, generally applicable for position tracking control of electro-hydraulic valve-cylinder drives (VCD's). The proposed control concept requires only common data sheet information and no knowledge on load...... extensive knowledge on system parameters nor advanced control theory. In order to accomplish this task, an integral sliding mode controller designed for the control derivative employing state observation is proposed, based on a generalized reduced order model structure of a VCD with unmatched valve ow......- and cylinder asymmetries. It is shown that limited attention can be given to bounds on parameter estimates, that chattering is reduced and the number of tuning parameters is reduced to the level seen in conventional PID schemes. Furthermore, simulation results demonstrate a high level of robustness when...

  17. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  18. Annular flow diverter valve

    International Nuclear Information System (INIS)

    Rider, R.L.

    1980-01-01

    A valve is described for diverting flow from the center of two concentric tubes to the annulus between the tubes or, operating in the reverse direction, for mixing fluids from concentric tubes into a common tube and for controlling the volume ratio of said flow. It consists of a toroidal baffle disposed in sliding engagement with the interior of the inner tube downstream of a plurality of ports in the inner tube, a plurality of gates in sliding engagement with the interior of the inner tube attached to the baffle for movement therewith, a servomotor having a bullet-shaped plug on the downstream end thereof, and drive rods connecting the servomotor to the toroidal baffle. The sevomotor is adapted to move the baffle into mating engagement with the bullet-shaped plug and simultaneously move the gates away from the ports in the inner tube and to move the baffle away from the bullet-shaped plug and simultaneously move the gates to cover the ports in the inner tube

  19. Types and sociodemographic correlates of complementary and alternative medicine (CAM) use among people with epilepsy in Oman.

    Science.gov (United States)

    Al Asmi, Abdullah; Al Maniri, Abdullah; Al-Farsi, Yahya M; Burke, David T; Al Asfoor, Fatema M H; Al Busaidi, Ibrahim; Al Breiki, Mohamed H A; Lahiri, Shaon; Braidy, Nady; Essa, Musthafa M; Al-Adawi, Samir

    2013-11-01

    Nonpharmacological treatment strategies that originate from sociocultural teachings and are beyond the scope of allopathic medicine are commonly used among people with epilepsy (PWE) in many parts of the world. The present study explored the types and sociodemographic correlates of complementary and alternative medicine (CAM) use among PWE in Oman among attendees of a neurological unit at a tertiary care center. Data on the types of CAM were gathered from telephone interviews. The relevant demographic and clinical characteristics of the participants were obtained from electronic medical records. Of the total of 101 participants, 73.3% were CAM users. The majority of these participants have not disclosed their CAM use to their allopathic health-care providers. The most common types of CAM reported were those falling under the 'mind-body' type (incantations and fumigation) and biologically based (herbal concoctions) or a combination of them. Compared to non-CAM users, a significant and greater proportion of CAM users attributed the etiology of their illness to nonbiomedical factors such as 'evil eyes' (P=0.04). The multivariate logistic regression model indicated that the use of CAM was highly associated with age of Oman. The most utilized type of CAM falls under the umbrella of mind-body practice. © 2013 Elsevier Inc. All rights reserved.

  20. Aortic valve surgery - open

    Science.gov (United States)

    ... gov/ency/article/007408.htm Aortic valve surgery - open To use the sharing features on this page, ... separates the heart and aorta. The aortic valve opens so blood can flow out. It then closes ...

  1. Problem: Mitral Valve Regurgitation

    Science.gov (United States)

    ... each time the left ventricle contracts. Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  2. Problem: Heart Valve Regurgitation

    Science.gov (United States)

    ... should be completely closed For example: Watch an animation of mitral valve regurgitation A leaking mitral valve ... Not Alone Popular Articles 1 Understanding Blood Pressure Readings 2 Sodium and Salt 3 Heart Attack Symptoms ...

  3. Experimental investigation of the fluid dynamic efficiency of a high performance multi-valve internal combustion engine during the intake phase: Influence of valve-valve interference phenomena

    Directory of Open Access Journals (Sweden)

    Algieri Angelo

    2013-01-01

    Full Text Available The purpose of the present work is the analysis of the fluid dynamic behavior of a high performance internal combustion engine during the intake phase. In particular, a four-valve spark-ignition engine has been characterized at the steady flow rig. Dimensionless discharge coefficients have been used to define the global fluid dynamic efficiency of the intake system, while the Laser Doppler Anemometry (LDA technique has been employed to evaluate the mean flow in the valve curtain area and to characterise the interference phenomena between the two intake valves. The investigation has shown the significant influence of the valve lift on the volumetric efficiency of the intake apparatus. Moreover, the experimental analysis has highlighted that the valve-valve interference phenomena have a relevant impact on the head breathability, on the flow development within the combustion chamber and on the velocity standard deviations.

  4. Are anticoagulant independent mechanical valves within reach-fast prototype fabrication and in vitro testing of innovative bi-leaflet valve models.

    Science.gov (United States)

    Scotten, Lawrence N; Siegel, Rolland

    2015-08-01

    Exploration for causes of prosthetic valve thrombogenicity has frequently focused on forward or post-closure flow detail. In prior laboratory studies, we uncovered high amplitude flow velocities of short duration close to valve closure implying potential for substantial shear stress with subsequent initiation of blood coagulation pathways. This may be relevant to widely accepted clinical disparity between mechanical and tissue valves vis-à-vis thrombogenicity. With a series of prototype bi-leaflet mechanical valves, we attempt reduction of closure related velocities with the objective of identifying a prototype valve with thrombogenic potential similar to our tissue valve control. This iterative design approach may find application in preclinical assessment of valves for anticoagulation independence. Tested valves included: prototype mechanical bi-leaflet BVs (n=56), controls (n=2) and patented early prototype mechanicals (n=2) from other investigators. Pulsatile and quasi-steady flow systems were used for testing. Projected dynamic valve area (PDVA) was measured using previously described novel technology. Flow velocity over the open and closing periods was determined by volumetric flow rate/PDVA. For the closed valve interval, use was made of data obtained from quasi-steady back pressure/flow tests. Performance was ranked by a proposed thrombogenicity potential index (TPI) relative to tissue and mechanical control valves. Optimization of the prototype valve designs lead to a 3-D printed model (BV3D). For the mitral/aortic site, BV3D has lower TPI (1.10/1.47) relative to the control mechanical valve (3.44/3.93) and similar to the control tissue valve (ideal TPI ≤1.0). Using unique technology, rapid prototyping and thrombogenicity ranking, optimization of experimental valves for reduced thrombogenic potential was expedited and simplified. Innovative mechanical valve configurations were identified that merit consideration for further development which may bring

  5. Prosthetic Aortic Valve Fixation Study: 48 Replacement Valves Analyzed Using Digital Pressure Mapping.

    Science.gov (United States)

    Lee, Candice Y; Wong, Joshua K; Ross, Ronald E; Liu, David C; Khabbaz, Kamal R; Martellaro, Angelo J; Gorea, Heather R; Sauer, Jude S; Knight, Peter A

    Prostheses attachment is critical in aortic valve replacement surgery, yet reliable prosthetic security remains a challenge. Accurate techniques to analyze prosthetic fixation pressures may enable the use of fewer sutures while reducing the risk of paravalvular leaks (PVL). Customized digital thin film pressure transducers were sutured between aortic annulus models and 21-mm bioprosthetic valves with 15 × 4-mm, 12 × 4-mm, or 9 × 6-mm-wide pledgeted mattress sutures. Simulating open and minimally invasive access, 4 surgeons, blinded to data acquisition, each secured 12 valves using manual knot-tying (hand-tied [HT] or knot-pusher [KP]) or automated titanium fasteners (TFs). Real-time pressure measurements and times were recorded. Two-dimensional (2D) and 3D pressure maps were generated for all valves. Pressures less than 80 mm Hg were considered at risk for PVL. Pressures under each knot (intrasuture) fell less than 80 mm Hg for 12 of 144 manual knots (5/144 HT, 7/144 KP) versus 0 of 288 TF (P prosthetic valve security.

  6. Community asset mapping, mobilisation and management (CA/M) approach: a case study

    CSIR Research Space (South Africa)

    Saidi, MEM

    2006-03-01

    Full Text Available by the community. The paper will present a practical application and recommendations based on a CA/M implementation in the Imperani Tourism and Training Centre (ITTC) project in Ficksburg. The ITTC experience has contributed to the development of a CA/M Guideline...

  7. Position paper -- Continuous air monitor (CAM) acquisition recommendation

    International Nuclear Information System (INIS)

    Hughes, M.E.

    1995-01-01

    The purpose of this position paper is to document the decision not to acquire continuous air monitors (CAM's) from government excess/surplus supplies. The procurement plan for equipment to be acquired for project W-236A, the Multi-Function Waste Tank Facility (MWTF), stipulates that radiation monitoring equipment will be supplied by WHC via the stock retained within the excess/surplus inventory or utilization of procured instruments from canceled projects. Technological advances within the radiation detection industry have ultimately outdated the instruments that are available within the excess/surplus stock. These machines represent the technology of the 1970's era. The CAM models in use or within the excess/surplus supplies are obsolete and have been discontinued by the manufacturer. Therefore, the majority of the excess/surplus CAM's are being reacquired and disassembled by instrument shops for in-house acquisition of spare parts for the instruments that are still presently in-service. It is being recommended by W-236A projects department that the strategy to acquire surplus/excess radiation monitoring devices be modified. The recommendation is to directly procure instruments that are equal to the technology available within this industry

  8. Discoloration of various CAD/CAM blocks after immersion in coffee

    Directory of Open Access Journals (Sweden)

    Sasipin Lauvahutanon

    2017-02-01

    Full Text Available Objectives This study evaluated color differences (ΔEs and translucency parameter changes (ΔTPs of various computer-aided design/computer-aided manufacturing (CAD/CAM blocks after immersion in coffee. Materials and Methods Eight CAD/CAM blocks and four restorative composite resins were evaluated. The CIE L*a*b* values of 2.0 mm thick disk-shaped specimens were measured using the spectrophotometer on white and black backgrounds (n = 6. The ΔEs and ΔTPs of one day, one week, and one month immersion in coffee or water were calculated. The values of each material were analyzed by two-way ANOVA and Tukey's multiple comparisons (α = 0.05. The ΔEs after prophylaxis paste polishing of 1 month coffee immersion specimens, water sorption and solubility were also evaluated. Results After one month in coffee, ΔEs of CAD/CAM composite resin blocks and restorative composites ranged from 1.6 to 3.7 and from 2.1 to 7.9, respectively, and ΔTPs decreased. The ANOVA of ΔEs and ΔTPs revealed significant differences in two main factors, immersion periods and media, and their interaction except for ΔEs of TEL (Telio CAD, Ivoclar Vivadent. The ΔEs significantly decreased after prophylaxis polishing except GRA (Gradia Block, GC. There was no significant correlation between ΔEs and water sorption or solubility in water. Conclusions The ΔEs of CAD/CAM blocks after immersion in coffee varied among products and were comparable to those of restorative composite resins. The discoloration of CAD/CAM composite resin blocks could be effectively removed with prophylaxis paste polishing, while that of some restorative composites could not be removed.

  9. Aortic valve function after bicuspidization of the unicuspid aortic valve.

    Science.gov (United States)

    Aicher, Diana; Bewarder, Moritz; Kindermann, Michael; Abdul-Khalique, Hashim; Schäfers, Hans-Joachim

    2013-05-01

    Unicuspid aortic valve (UAV) anatomy leads to dysfunction of the valve in young individuals. We introduced a reconstructive technique of bicuspidizing the UAV. Initially we copied the typical asymmetry of a normal bicuspid aortic valve (BAV) (I), later we created a symmetric BAV (II). This study compared the hemodynamic function of the two designs of a bicuspidized UAV. Aortic valve function was studied at rest and during exercise in 28 patients after repair of UAV (group I, n = 8; group II, n = 20). There were no differences among the groups I and II with respect to gender, age, body size, or weight. All patients were in New York Heart Association class I. Six healthy adults served as control individuals. All patients were studied with transthoracic echocardiography between 4 and 65 months postoperatively. Systolic gradients were assessed by continuous wave Doppler while patients were at rest and exercising on a bicycle ergometer. Aortic regurgitation was grade I or less in all patients. Resting gradients were significantly elevated in group I compared with group II and control individuals (group I, peak 33.8 ± 7.8 mm Hg; mean 19.1 ± 5.4 mm Hg; group II, peak 15.8 ± 5.4, mean 8.2 ± 2.8 mm Hg; control individuals, peak 6.0 ± 1.6, mean 3.2 ± 0.8 mm Hg; p competence. A symmetric repair design leads to improved systolic aortic valve function at rest and during exercise. Copyright © 2013 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  10. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  11. Influence of Different CAM Strategies on the Fit of Partial Crown Restorations: A Digital Three-dimensional Evaluation.

    Science.gov (United States)

    Zimmermann, M; Valcanaia, A; Neiva, G; Mehl, A; Fasbinder, D

    2018-04-09

    CAM fabrication is an important step within the CAD/CAM process. The internal fit of restorations is influenced by the accuracy of the subtractive CAM procedure. Little is known about how CAM strategies might influence the fit of CAD/CAM fabricated restorations. The aim of this study was to three-dimensionally evaluate the fit of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns fabricated with three different CAM strategies. The null hypothesis was that different CAM strategies did not influence the fitting accuracy of CAD/CAM fabricated zirconia-reinforced lithium silicate ceramic partial crowns. Preparation for a partial crown was performed on a maxillary right first molar on a typodont. A chairside CAD/CAM system with the intraoral scanning device CEREC Omnicam (Dentsply Sirona, York, PA, USA) and the 3+1 axis milling unit CEREC MCXL was used. There were three groups with different CAM strategies: step bur 12 (12), step bur 12S (12S), and two step-mode (12TWO). The zirconia-reinforced lithium silicate ceramic Celtra Duo (Dentsply Sirona) was used as the CAD/CAM material. A new 3D method for evaluating the fit was applied, consisting of the quadrant scan with the intraoral scanning device CEREC Omnicam. The scan of the PVS material adherent to the preparation and the preparation scan were matched, and the difference analysis was performed with special software OraCheck (Cyfex AG, Zurich, Switzerland). Three areas were selected for analysis: margin (MA), axial (AX), and occlusal (OC). Statistical analysis was performed using 80% percentile, one-way ANOVA, and the post hoc Scheffé test with α=0.05. Statistically significant differences were found both within and between the test groups. The aspect axial fit results varied from 90.5 ± 20.1 μm for the two-step milling mode (12TWO_AX) to 122.8 ± 12.2 μm for the milling with step bur 12S (12S_AX). The worst result in all groups was found for the aspect occlusal fit with the highest

  12. Cavitation problems in sodium valves

    International Nuclear Information System (INIS)

    Elie, X.

    1976-01-01

    Cavitation poses few problems for sodium valves, in spite of the fact that the loops are not pressurized. This is no doubt due to the low flow velocities in the pipes. For auxiliary loop valves we are attempting to standardize performances with respect to cavitation. For economic reasons cavitation thresholds are approached with large diameter valves. (author)

  13. Special Section: Complementary and Alternative Medicine (CAM):Quiz on Complementary and Alternative Medicine

    Science.gov (United States)

    ... Special Section CAM Quiz on Complementary and Alternative Medicine Past Issues / Winter 2009 Table of Contents For ... low back pain. True False Complementary and alternative medicine (CAM) includes: Meditation Chiropractic Use of natural products, ...

  14. Tufting enteropathy with EpCAM mutation: case report

    Directory of Open Access Journals (Sweden)

    Karla Lais Pêgas

    2014-06-01

    Full Text Available Tufting enteropathy (TE, also known as intestinal epithelial dysplasia (IED, is a rare congenital enteropathy related to an earlyonset of severe intractable diarrhea due to specific abnormalities of the intestinal epithelium and mutations of the EpCAM gene. TE is characterized by clinical and histological heterogeneity, such as with low or without mononuclear cell infiltration of the lamina propria, and abnormalities of basement membrane. TE can be associated with malformations, other epithelial diseases, or to abnormal enterocytes development and/or differentiation. The authors report a case of a Brazilian child with TE associated with c.556-14A>G mutation in the EpCAM gene (NM_002354.2.

  15. Comparative characterization of a novel cad-cam polymer-infiltrated-ceramic-network.

    Science.gov (United States)

    Albero, Alberto; Pascual, Agustín; Camps, Isabel; Grau-Benitez, María

    2015-10-01

    The field of dental ceramics for CAD-CAM is enriched with a new innovative material composition having a porous three-dimensional structure of feldspathic ceramic infiltrated with acrylic resins.The aim of this study is to determine the mechanical properties of Polymer-Infiltrated-Ceramic-Network (PICN) and compare its performance with other ceramics and a nano-ceramic resin available for CAD-CAM systems. In this study a total of five different materials for CAD-CAM were investigated. A polymer-infiltrated ceramic (Vita Enamic), a nano-ceramic resin (Lava Ultimate), a feldspathic ceramic (Mark II), a lithium disilicate ceramic (IPS-e max CAD) and finally a Leucite based ceramic (Empress - CAD). From CAD-CAM blocks, 120 bars (30 for each material cited above) were cut to measure the flexural strength with a three-point-bending test. Strain at failure, fracture stress and Weibull modulus was calculated. Vickers hardness of each material was also measured. IPS-EMAX presents mechanical properties significantly better from the other materials studied. Its strain at failure, flexural strength and hardness exhibited significantly higher values in comparison with the others. VITA ENAMIC and LAVA ULTIMATE stand out as the next most resistant materials. The flexural strength, elastic modulus similar to a tooth as well as having less hardness than ceramics make PICN materials an option to consider as a restorative material. Ceramic infiltrated with resin, CAD-CAM, Weibull modulus, flexural strength, micro hardness.

  16. Valve testing for UK PWR safety applications

    International Nuclear Information System (INIS)

    George, P.T.; Bryant, S.

    1989-01-01

    Extensive testing and development has been done by the Central Electricity Generating Board (CEGB) to support the design, construction and operation of Sizewell B, the UK's first PWR. A Blowdown Rig for the Assessment of Valve Operability - (BRAVO) has been constructed at the CEGB Marchwood Engineering Laboratory to reproduce PWR Pressurizer fluid conditions for the full scale testing of Pressurizer Relief System (PRS) valves. A full size tandem pair of Pilot Operated Safety Relief Valves (POSRVs) is being tested under the full range of pressurizer fluid conditions. Tests to date have produced important data on the performance of the valve in its Cold Overpressure protection mode of operation and on methods for the in-service testing of the valve. Also, a full size pressurizer safety valve has been tested under full PRS fluid conditions to develop a methodology for the pre-service testing of the Sizewell valves. Further work will be carried out to develop procedures for the in-service testing of the valve. In the Main Steam Safety Valve test program carried out at the Siemens-KWU Test Facilities, a single MSSV from three potential suppliers was tested under full secondary system conditions. The test results have been analyzed and are reflected in the CEGB's arrangements for the pre-service and in-service testing of the Sizewell MSSVs. Valves required to interrupt pipebreak flow must be qualified for this duty by testing or a combination of testing and analysis. To obtain guidance on the performance of such tests gate and globe valves have been subjected to simulated pipebreaks under PWR primary circuit conditions. In the light of problems encountered with gate valve closure under these conditions, further tests are currently being carried out on the BRAVO facility on a gate valve, in preparation for the full scale flow interruption qualification testing of the Sizewell main steam isolation valve

  17. Memory for staged events: Supporting older and younger adults' memory with SenseCam.

    Science.gov (United States)

    Mair, Ali; Poirier, Marie; Conway, Martin A

    2018-03-01

    Two experiments measured the effect of retrieval support provided by a wearable camera, SenseCam, on older and younger adults' memory for a recently experienced complex staged event. In each experiment, participants completed a series of tasks in groups, and the events were recalled 2 weeks later, after viewing SenseCam images (experimental condition) or thinking about the event (control condition). When IQ and education were matched, young adults recalled more event details than older adults, demonstrating an age-related deficit for novel autobiographical material. Reviewing SenseCam images increased the number of details recalled by older and younger adults, and the effect was similar for both groups. These results suggest that memory can be supported by the use of SenseCam, but the age-related deficit is not eliminated.

  18. Valve assembly having remotely replaceable bearings

    International Nuclear Information System (INIS)

    Johnson, E.R.; Tanner, D.E.

    1980-01-01

    A valve assembly having remotely replaceable bearings is disclosed wherein a valve disc is supported within a flow duct for rotation about a pair of axially aligned bearings, one of which is carried by a spindle received within a diametral bore in the valve disc, and the other of which is carried by a bearing support block releasably mounted on the duct circumferentially of an annular collar on the valve disc coaxial with its diametrical bore. The spindle and bearing support block are adapted for remote removal to facilitate servicing or replacement of the valve disc support bearings

  19. Krox20 defines a subpopulation of cardiac neural crest cells contributing to arterial valves and bicuspid aortic valve.

    Science.gov (United States)

    Odelin, Gaëlle; Faure, Emilie; Coulpier, Fanny; Di Bonito, Maria; Bajolle, Fanny; Studer, Michèle; Avierinos, Jean-François; Charnay, Patrick; Topilko, Piotr; Zaffran, Stéphane

    2018-01-03

    Although cardiac neural crest cells are required at early stages of arterial valve development, their contribution during valvular leaflet maturation remains poorly understood. Here, we show in mouse that neural crest cells from pre-otic and post-otic regions make distinct contributions to the arterial valve leaflets. Genetic fate-mapping analysis of Krox20-expressing neural crest cells shows a large contribution to the borders and the interleaflet triangles of the arterial valves. Loss of Krox20 function results in hyperplastic aortic valve and partially penetrant bicuspid aortic valve formation. Similar defects are observed in neural crest Krox20 -deficient embryos. Genetic lineage tracing in Krox20 -/- mutant mice shows that endothelial-derived cells are normal, whereas neural crest-derived cells are abnormally increased in number and misplaced in the valve leaflets. In contrast, genetic ablation of Krox20 -expressing cells is not sufficient to cause an aortic valve defect, suggesting that adjacent cells can compensate this depletion. Our findings demonstrate a crucial role for Krox20 in arterial valve development and reveal that an excess of neural crest cells may be associated with bicuspid aortic valve. © 2018. Published by The Company of Biologists Ltd.

  20. Expression of EpCam and Villin in Barrett’s Esophagus and in Gastric Cardia

    Directory of Open Access Journals (Sweden)

    Mario Anders

    2008-01-01

    Full Text Available In the current study we aimed to clarify the potential of EpCAM and villin as in vivo biomarkers for both Barrett esophagus (BE-associated neoplasia and BE versus cardiac mucosa. Immunohistochemical staining in BE with various degrees of intraepithelial neoplasia (IN, Barrett carcinoma (BC and in normal cardiac mucosa (CM revealed a lack of EpCam and villin in squamous esophageal epithelium. All specimens of IN and BC showed EpCam with varying staining intensities. In 57% of CM samples a weak signal was detected; the remainder displayed strong EpCam expression. Villin was found in 97% of BE specimens and in all those with IN; 37% of BC and 75% of CM specimens were also positive. We conclude that expression of EpCam and villin differs only between squamous epithelium and BE. Determination of these proteins does not allow discrimination between different degrees of neoplasia or between esophageal intestinal metaplasia and cardiac mucosa.

  1. Missed aortic valve endocarditis resulting in complete atrioventricular block and redo mechanical valve replacement.

    Science.gov (United States)

    Harky, Amer; Garner, Megan; Popa, Miruna; Shipolini, Alex

    2017-08-03

    Infective endocarditis is a rare disease associated with high morbidity and mortality. As a result, early diagnosis and prompt antibiotic treatment with or without surgical intervention is crucial in the management of such condition.We report a case of missed infective endocarditis of the aortic valve. The patient underwent mechanical aortic valve replacement, with the native valve being sent for histopathological examination. On re-admission 16 months later, he presented with syncope, shortness of breathing and complete heart block. On review of the histopathology of native aortic valve, endocarditis was identified which had not been acted on. The patient underwent redo aortic valve replacement for severe aortic regurgitation.We highlight the importance of following up histopathological results as well as the need for multidisciplinary treatment of endocarditis with a combination of surgical and antibiotic therapy. © BMJ Publishing Group Ltd (unless otherwise stated in the text of the article) 2017. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  2. Improved corrosion resistance of spin-valve film

    International Nuclear Information System (INIS)

    Tetsukawa, H.; Hommura, H.; Okabe, A.; Soda, Y.

    2007-01-01

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head

  3. Improved corrosion resistance of spin-valve film

    Energy Technology Data Exchange (ETDEWEB)

    Tetsukawa, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)]. E-mail: tetsukaw@arc.sony.co.jp; Hommura, H. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Okabe, A. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan); Soda, Y. [Sony Corporation, 6-7-35 Kitashinagawa, Shinagawa-ku, Tokyo 141-0001 (Japan)

    2007-06-15

    We investigated the corrosion behavior and magnetoresistance of spin-valve film in order to improve the corrosion resistance of the spin-valve head for a tape recording system. The conventional spin-valve head (sub./Ta/NiFe/CoFe/Cu/CoFe/PtMn/Ta) with no diamond-like carbon (DLC) protective layer showed poor corrosion resistance. This is because the CoFe for ferromagnetic layer and Cu for spacer in the spin-valve film exhibited poor corrosion resistance. The corrosion resistance of the CoFe film and Cu film improved with the addition of Ni and Au, respectively. The spin-valve film (sub./Ta/NiFe/CoNiFe/CuAu/CoNiFe/PtMn/Ta) showed higher pitting potential than the conventional spin-valve film by +0.45 V. This presents a significant improvement over the conventional spin-valve film. We also investigated the effect of the composition of ferromagnetic layer and spacer on the magnetoresistance of the spin-valve film. The magnetoresistance of the spin-valve film by substitution of CoNiFe for CoFe in ferromagnetic layer decreased slightly. The magnetoresistance of the spin-valve film decreased as the addition of Au of the spacer increased. The diffusion at CoNiFe/CuAu interface has not been observed in annealing process. The quantitative relation between corrosion resistance and magnetoresistance of spin-valve film, and its ferromagnetic layer and spacer's compositions have been clarified. The output voltage at 50 Oe of the corrosion-resistant spin-valve head with CoNiFe ferromagnetic layer and CuAu spacer was about 50% of that of the conventional spin-valve head.

  4. [Tricuspid valve insufficiency: what should be done?].

    Science.gov (United States)

    von Segesser, L K; Stauffer, J C; Delabays, A; Chassot, P G

    1998-12-01

    Tricuspid regurgitation is relatively common. Due to the progress made in echocardiography, its diagnosis is in general made readily and in reliable fashion. Basically one has to distinguish between functional tricuspid valve regurgitation due to volume and/or pressure overload of the right ventricle with intact valve structures versus tricuspid valve regurgitation due to pathologic valve structures. The clear identification of the regurgitation mechanism is of prime importance for the treatment. Functional tricuspid valve regurgitation can often be improved by medical treatment of heart failure, and eventually a tricuspid valve plasty can solve the problem. However, the presence of pathologic tricuspid valve structures makes in general more specific plastic surgical procedures and even prosthetic valve replacements necessary. A typical example for a structural tricuspid valve regurgitation is the case of a traumatic papillary muscle rupture. Due to the sudden onset, this pathology is not well tolerated and requires in general surgical reinsertion of the papillary muscle. In contrast, tricuspid valve regurgitation resulting from chronic pulmonary embolism with pulmonary artery hypertension, can be improved by pulmonary artery thrombendarteriectomy and even completely cured with an additional tricuspid annuloplasty. However, tricuspid regurgitations due to terminal heart failure are not be addressed with surgery directed to tricuspid valve repair or replacement. Heart transplantation, dynamic cardiomyoplasty or mechanical circulatory support should be evaluated instead.

  5. Quantitative determination of the organ distribution of the cell adhesion molecule cell-CAM 105 by radioimmunoassay

    International Nuclear Information System (INIS)

    Odin, P.; Oebrink, B.

    1987-01-01

    The authors have previously identified a 105,000-Da plasma membrane glycoprotein, denoted cell-CAM 105, that is involved in intercellular adhesion of reaggregating rat hepatocytes. In this communication they report on the development of a radioimmunoassay for cell-CAM 105, employing purified cell-CAM 105, specific antisera against the molecule, and formalin-fixed protein A-containing staphylococci for precipitation of the immune complexes. The assay was shown to be sensitive, specific, precise, rapid, and easy to perform. They used this radioimmunoassay in investigations of the occurrence of cell-CAM 105 in different rat organs. Cell-CAM 105 was present in a wide spectrum of organs in varying amounts. The highest concentrations were found in the gastrointestinal tract, liver, some secretory glands, vagina, kidney, and lung. The results were confirmed by immunoblotting, which revealed one distinct protein component, corresponding to cell-CAM 105, in each positive organ

  6. Supercharged two-cycle engines employing novel single element reciprocating shuttle inlet valve mechanisms and with a variable compression ratio

    Science.gov (United States)

    Wiesen, Bernard (Inventor)

    2008-01-01

    This invention relates to novel reciprocating shuttle inlet valves, effective with every type of two-cycle engine, from small high-speed single cylinder model engines, to large low-speed multiple cylinder engines, employing spark or compression ignition. Also permitting the elimination of out-of-phase piston arrangements to control scavenging and supercharging of opposed-piston engines. The reciprocating shuttle inlet valve (32) and its operating mechanism (34) is constructed as a single and simple uncomplicated member, in combination with the lost-motion abutments, (46) and (48), formed in a piston skirt, obviating the need for any complex mechanisms or auxiliary drives, unaffected by heat, friction, wear or inertial forces. The reciprocating shuttle inlet valve retains the simplicity and advantages of two-cycle engines, while permitting an increase in volumetric efficiency and performance, thereby increasing the range of usefulness of two-cycle engines into many areas that are now dominated by the four-cycle engine.

  7. Mitral valve surgery - open

    Science.gov (United States)

    ... Taking warfarin (Coumadin) References Otto CM, Bonow RO. Valvular heart disease. In: Mann DL, Zipes DP, Libby P, Bonow ... A.M. Editorial team. Heart Surgery Read more Heart Valve Diseases Read more Mitral Valve Prolapse Read more A. ...

  8. Check valves aging assessment

    International Nuclear Information System (INIS)

    Haynes, H.D.

    1991-01-01

    In support of the NRC Nuclear Plant Aging Research (NPAR) program, the Oak Ridge National Laboratory (ORNL) has carried out an assessment of several check value diagnostic monitoring methods, in particular, those based on measurements of acoustic emission, ultrasonics, and magnetic flux. The evaluations have focussed on the capabilities of each method to provide information useful in determining check valve aging and service wear effects, check valve failures, and undesirable operating modes. This paper describes the benefits and limitations associated with each method and includes recent laboratory and field test data, including data obtained from the vendors who recently participated in a comprehensive series of tests directed by a nuclear industry users group. In addition, as part of the ORNL Advanced Diagnostic Engineering Research and Development Center (ADEC), two novel nonintrusive monitoring methods were developed that provide several unique capabilities. These methods, based on external ac- an dc-magnetic monitoring are also described. None of the examined methods could, by themselves, monitor both the instantaneous position and motion of check valve internals and valve leakage; however, the combination of acoustic emission monitoring with one of the other methods provides the means to determine vital check valve operational information

  9. Top closure for control rod drive for nuclear reactor

    International Nuclear Information System (INIS)

    Raas, J.H.; Schwartz, J.I.

    1978-01-01

    A removable top closure and venting assembly for the tubular housing of a control rod drive includes a mounting ring threadably inserted in the upper end of the housing, a fluid-sealing closure member beneath the mounting ring and which is mounted in and coupled to the mounting ring by means of a ball and socket joint, a gas vent defined by interconnecting passages extending through the closure and through the ball and socket joint, and a vent valve accessible from the top of the closure assembly. 3 claims, 2 figures

  10. Corrosion of valve metals

    International Nuclear Information System (INIS)

    Draley, J.E.

    1976-01-01

    A general survey related to the corrosion of valve metals or film-forming metals. The way these metals corrode with some general examples is described. Valve metals form relatively perfect oxide films with little breakdown or leakage when anodized

  11. Echocardiographic Assessment of Heart Valve Prostheses

    Science.gov (United States)

    Sordelli, Chiara; Severino, Sergio; Ascione, Luigi; Coppolino, Pasquale; Caso, Pio

    2014-01-01

    Patients submitted to valve replacement with mechanical or biological prosthesis, may present symptoms related either to valvular malfunction or ventricular dysfunction from other causes. Because a clinical examination is not sufficient to evaluate a prosthetic valve, several diagnostic methods have been proposed to assess the functional status of a prosthetic valve. This review provides an overview of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. Compared to native valves, echocardiographic evaluation of prosthetic valves is certainly more complex, both for the examination and the interpretation. Echocardiography also allows discriminating between intra- and/or peri-prosthetic regurgitation, present in the majority of mechanical valves. Transthoracic echocardiography (TTE) requires different angles of the probe with unconventional views. Transesophageal echocardiography (TEE) is the method of choice in presence of technical difficulties. Three-dimensional (3D)-TEE seems to be superior to 2D-TEE, especially in the assessment of paravalvular leak regurgitation (PVL) that it provides improved localization and analysis of the PVL size and shape. PMID:28465917

  12. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  13. The radiology of prosthetic heart valves

    International Nuclear Information System (INIS)

    Steiner, R.M.; Flicker, S.

    1985-01-01

    The development of prosthetic heart valves in the late 1950s ushered in a new era in the treatment of heart disease. The radiologist has an important role to play preoperatively in the diagnosis of valvular heart disease. Radiology is valuable in identification of the implanted prosthetic valve and recognition of complications associated with valve implantation. Radiologists must be familiar with the imaging techniques best suited to evaluate the function of the valve prosthesis in question. In this chapter the authors discuss the radiographic approach to the evaluation of the status of patients for valve replacement and the imaging problems peculiar to the types of valves in current use. The relative value of plain-film radiography, fluoroscopy, videorecording and cinerecording, and aortography is addressed, as well as the potential value of magnetic resonance imaging and subsecond dynamic computed tomography

  14. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  15. JunoCam Images of Jupiter: Science from an Outreach Experiment

    Science.gov (United States)

    Hansen, C. J.; Orton, G. S.; Caplinger, M. A.; Ravine, M. A.; Rogers, J.; Eichstädt, G.; Jensen, E.; Bolton, S. J.; Momary, T.; Ingersoll, A. P.

    2017-12-01

    The Juno mission to Jupiter carries a visible imager on its payload primarily for outreach, and also very useful for jovian atmospheric science. Lacking a formal imaging science team, members of the public have volunteered to process JunoCam images. Lightly processed and raw JunoCam data are posted on the JunoCam webpage at https://missionjuno.swri.edu/junocam/processing. Citizen scientists download these images and upload their processed contributions. JunoCam images through broadband red, green and blue filters and a narrowband methane filter centered at 889 nm mounted directly on the detector. JunoCam is a push-frame imager with a 58 deg wide field of view covering a 1600 pixel width, and builds the second dimension of the image as the spacecraft rotates. This design enables capture of the entire pole of Jupiter in a single image at low emission angle when Juno is 1 hour from perijove (closest approach). At perijove the wide field of view images are high-resolution while still capturing entire storms, e.g. the Great Red Spot. Juno's unique polar orbit yields polar perspectives unavailable to earth-based observers or most previous spacecraft. The first discovery was that the familiar belt-zone structure gives way to more chaotic storms, with cyclones grouped around both the north and south poles [1, 2]. Recent time-lapse sequences have enabled measurement of the rotation rates and wind speeds of these circumpolar cyclones [3]. Other topics are being investigated with substantial, in many cases essential, contributions from citizen scientists. These include correlating the high resolution JunoCam images to storms and disruptions of the belts and zones tracked throughout the historical record. A phase function for Jupiter is being developed empirically to allow image brightness to be flattened from the subsolar point to the terminator. We are studying high hazes and the stratigraphy of the upper atmosphere, utilizing the methane filter, structures illuminated

  16. All in the family: matrimonial mitral valve clicks.

    Science.gov (United States)

    Desser, K B; Bokhari, S I; Benchimol, A; Romney, D

    1981-05-01

    Mitral valve clicks with or without late systolic murmurs were detected in genetically unrelated marital partners of 5 families. The first family represented 2 successive nonconsanguineous marital unions with 3 generations of mitral valve clicks. The second family included 1 natural and 2 adopted children with clinical and echographic evidence of mitral valve prolapse. The third family was comprised of asymptomatic parents, both with nonejection clicks and mitral valve prolapse, whose daughter presented 3 years previously with syncope, palpitations, and combined mitral and tricuspid valve prolapse. The fourth family had 3 members with auscultatory and ultrasonic manifestations of billowing mitral valve, whereas the fourth member had "silent mitral valve prolapse." The fifth family represented a mother with auscultatory and echographic evidence of mitral valve prolapse; her 14-year-old daughter had both mitral and tricuspid valve prolapse, whereas the son had a bicuspid aortic valve. Both children were products of a prior marriage, and her husband has symptomatic mitral valve prolapse. We conclude that matrimonial mitral valve prolapse probably reflects the purported (6--10%) prevalence of this disorder in the general population. The consequences of such marital union on progeny is currently unclear and warrants future investigation.

  17. Is Ep-CAM Expression a Diagnostic and Prognostic Biomarker for Colorectal Cancer? A Systematic Meta-Analysis

    Directory of Open Access Journals (Sweden)

    Susu Han

    2017-06-01

    Conclusions: The present findings suggest that Ep-CAM expression may be associated with CRC carcinogenesis, while the loss of Ep-CAM expression is correlated with the progression, metastasis, and poor prognosis of CRC. Ep-CAM expression may be a useful biomarker for the clinical diagnosis of CRC.

  18. Use of Complementary and Alternative Medicine (CAM) in cancer patients: An Italian multicenter survey.

    Science.gov (United States)

    Berretta, Massimiliano; Della Pepa, Chiara; Tralongo, Paolo; Fulvi, Alberto; Martellotta, Ferdinando; Lleshi, Arben; Nasti, Guglielmo; Fisichella, Rossella; Romano, Carmela; De Divitiis, Chiara; Taibi, Rosaria; Fiorica, Francesco; Di Francia, Raffaele; Di Mari, Anna; Del Pup, Lino; Crispo, Anna; De Paoli, Paolo; Santorelli, Adriano; Quagliariello, Vincenzo; Iaffaioli, Rosario Vincenzo; Tirelli, Umberto; Facchini, Gaetano

    2017-04-11

    Complementary and Alternative Medicine (CAM) include a wide range of products (herbs, vitamins, minerals, and probiotics) and medical practices, developed outside of the mainstream Western medicine. Patients with cancer are more likely to resort to CAM first or then in their disease history; the potential side effects as well as the costs of such practices are largely underestimated. We conducted a descriptive survey in five Italian hospitals involving 468 patients with different malignancies. The survey consisted of a forty-two question questionnaire, patients were eligible if they were Italian-speaking and receiving an anticancer treatment at the time of the survey or had received an anticancer treatment no more than three years before participating in the survey. Of our patients, 48.9% said they use or have recently used CAM. The univariate analysis showed that female gender, high education, receiving treatment in a highly specialized institute and receiving chemotherapy are associated with CAM use; at the multivariate analysis high education (Odds Ratio, (OR): 1.96 95% Confidence Interval, CI, 1.27-3.05) and receiving treatment in a specialized cancer center (OR: 2.75 95% CI, 1.53-4.94) were confirmed as risk factors for CAM use. Roughly half of our patients receiving treatment for cancer use CAM. It is necessary that health professional explore the use of CAM with their cancer patients, educate them about potentially beneficial therapies in light of the limited available evidence of effectiveness, and work towards an integrated model of health-care provision.

  19. Echocardiographic evaluation of heart valve prosthetic dysfunction

    Directory of Open Access Journals (Sweden)

    Yuriy Ivaniv

    2018-02-01

    Full Text Available Patients with replaced heart valve submitted to echocardiographic examination may have symptoms related either to valvular malfunction or ventricular dysfunction from different causes. Clinical examination is not reliable in a prosthetic valve evaluation and the main information regarding its function could be obtained using different cardiac ultrasound modalities. This review provides a description of echocardiographic and Doppler techniques useful in evaluation of prosthetic heart valves. For the interpretation of echocardiography there is a need in special knowledge of prosthesis types and possible reasons of prosthetic function deterioration. Echocardiography allows to reveal valve thrombosis, pannus formation, vegetation and such complications of infective endocarditis as valve ring abscess or dehiscence. Transthoracic echocardiography requires different section plane angles and unconventional views. Transesophageal echocardiography is more often used than in native valve examination due to better visualization of prosthetic valve structure and function. Three-dimensional echocardiography could provide more detailed visual information especially in the assessment of paravalvular regurgitation or valve obstruction.

  20. High-risk Trans-Catheter Aortic Valve Replacement in a Failed Freestyle Valve with Low Coronary Height: A Case Report.

    Science.gov (United States)

    Karimi, Ashkan; Pourafshar, Negiin; Dibu, George; Beaver, Thomas M; Bavry, Anthony A

    2017-06-01

    A 55-year-old male with a history of two prior cardiac surgeries presented with decompensated heart failure due to severe bioprosthetic aortic valve insufficiency. A third operation was viewed prohibitively high risk and valve-in-valve trans-catheter aortic valve replacement was considered. There were however several high-risk features and technically challenging aspects including low coronary ostia height, poor visualization of the aortic sinuses, and difficulty in identification of the coplanar view due to severe aortic insufficiency, and a highly mobile aortic valve mass. After meticulous peri-procedural planning, trans-catheter aortic valve replacement was carried out with a SAPIEN 3 balloon-expandable valve without any complication. Strategies undertaken to navigate the technically challenging aspects of the case are discussed.

  1. Comparison of 3D Echocardiogram-Derived 3D Printed Valve Models to Molded Models for Simulated Repair of Pediatric Atrioventricular Valves.

    Science.gov (United States)

    Scanlan, Adam B; Nguyen, Alex V; Ilina, Anna; Lasso, Andras; Cripe, Linnea; Jegatheeswaran, Anusha; Silvestro, Elizabeth; McGowan, Francis X; Mascio, Christopher E; Fuller, Stephanie; Spray, Thomas L; Cohen, Meryl S; Fichtinger, Gabor; Jolley, Matthew A

    2018-03-01

    Mastering the technical skills required to perform pediatric cardiac valve surgery is challenging in part due to limited opportunity for practice. Transformation of 3D echocardiographic (echo) images of congenitally abnormal heart valves to realistic physical models could allow patient-specific simulation of surgical valve repair. We compared materials, processes, and costs for 3D printing and molding of patient-specific models for visualization and surgical simulation of congenitally abnormal heart valves. Pediatric atrioventricular valves (mitral, tricuspid, and common atrioventricular valve) were modeled from transthoracic 3D echo images using semi-automated methods implemented as custom modules in 3D Slicer. Valve models were then both 3D printed in soft materials and molded in silicone using 3D printed "negative" molds. Using pre-defined assessment criteria, valve models were evaluated by congenital cardiac surgeons to determine suitability for simulation. Surgeon assessment indicated that the molded valves had superior material properties for the purposes of simulation compared to directly printed valves (p 3D echo-derived molded valves are a step toward realistic simulation of complex valve repairs but require more time and labor to create than directly printed models. Patient-specific simulation of valve repair in children using such models may be useful for surgical training and simulation of complex congenital cases.

  2. [Pannus Formation Six-years after Aortic and Mitral Valve Replacement with Tissue Valves;Report of a Case].

    Science.gov (United States)

    Nakamura, Makoto; Muraoka, Arata; Aizawa, Kei; Akutsu, Hirohiko; Kurumisawa, Soki; Misawa, Yoshio

    2015-07-01

    A 77-year-old man presented with exertional dyspnea. He had undergone aortic and mitral valve replacement with tissue valves 6-years earlier. The patient's hemoglobin level was 9.8 g/dl and serum aspartate aminotransferase (70 mU/ml) and lactate dehydrogenase (1,112 mU/ml) were elevated. Echocardiography revealed stenosis of the prosthetic valve in the aortic position with peak flow velocity of 3.8 m/second and massive mitral regurgitation. The patient underwent repeat valve replacement. Pannus formation around both implanted valves was observed. The aortic valve orifice was narrowed by the pannus, and one cusp of the prosthesis in the mitral position was fixed and caused the regurgitation, but they were free from cusp laceration or calcification. The patient's postoperative course was uneventful, and he continues to do well 14 months after surgery.

  3. Transcription factors and molecular epigenetic marks underlying EpCAM overexpression in ovarian cancer

    NARCIS (Netherlands)

    van der Gun, B. T. F.; de Groote, M. L.; Kazemier, H. G.; Arendzen, A. J.; Terpstra, P.; Ruiters, M. H. J.; McLaughlin, P. M. J.; Rots, M. G.

    2011-01-01

    BACKGROUND: The epithelial cell adhesion molecule (EpCAM) is overexpressed on carcinomas, and its downregulation inhibits the oncogenic potential of multiple tumour types. Here, we investigated underlying mechanisms of epcam overexpression in ovarian carcinoma. METHODS: Expression of EpCAM and DNA

  4. Safety valve opening and closing operation monitor

    International Nuclear Information System (INIS)

    Kodama, Kunio; Takeshima, Ikuo; Takahashi, Kiyokazu.

    1981-01-01

    Purpose: To enable the detection of the closing of a safety valve when the internal pressure in a BWR type reactor is a value which will close the safety valve, by inputting signals from a pressure detecting device mounted directly at a reactor vessel and a safety valve discharge pressure detecting device to an AND logic circuit. Constitution: A safety valve monitor is formed of a pressure switch mounted at a reactor pressure vessel, a pressure switch mounted at the exhaust pipe of the escape safety valve and a logic circuit and the lide. When the input pressure of the safety valve is raised so that the valve and the pressure switch mounted at the exhaust pipe are operated, an alarm is indicated, and the operation of the pressure switch mounted at a pressure vessel is eliminated. If the safety valve is not reclosed when the vessel pressure is decreased lower than the pressure at which it is to be reclosed after the safety valve is operated, an alarm is generated by the logic circuit since both the pressure switches are operated. (Sekiya, K.)

  5. Illness narratives in cancer: CAM and spiritual practices

    DEFF Research Database (Denmark)

    Ulrich, Anita; Evron, Lotte; Ostenfeld-Rosenthal, Ann

    2011-01-01

    Objectives: In this paper,we investigate Danish cancer patients’ narratives on spiritual beliefs and practices and the relationship these practices may have to complementary and alternative medicine (CAM). Design: Narrative inquiry is used to uncover how spiritual beliefs and practices may......, religious and spiritual issues were not extensively unfolded in participants’ illness narratives. However, these issues were significantly elaborated on in narratives by four female participants. Conclusion: We propose that for some cancer patients CAM may function, not only or primarily as a treatment...... for cancer related symptoms and side effects, but as a spiritual practice as well. For some individuals this may be true to an even higher extent than in established religious institutions....

  6. Sources of CAM3 vorticity bias during northern winter from diagnostic study of the vorticity equation

    Energy Technology Data Exchange (ETDEWEB)

    Grotjahn, Richard [University of California, Department of Land, Air and Water Resources, Davis, CA (United States); Pan, Lin-Lin; Tribbia, Joseph [National Center for Atmospheric Research, Boulder, CO (United States)

    2011-06-15

    CAM3 (Community Atmosphere Model version 3) simulation bias is diagnosed using the vorticity equation. The study compares CAM3 output with ECMWF (European Centre for Medium-Range Weather Forecasts) 40 year reanalysis (ERA-40) data. A time mean vorticity bias equation is also formulated and the terms are grouped into categories: linear terms, nonlinear terms, transient contributions, and friction (calculated as a residual). Frontal cyclone storms have much weaker band passed kinetic energy and enstrophy in CAM3. The downstream end of the North Atlantic storm track (NAST) has large location error. While the vorticity equation terms have similar amplitude ranking in CAM3 and ERA-40 at upper levels, the ranking differs notably in the lower troposphere. The linear and friction terms dominate the vorticity bias equation. The transient terms contribute along the storm track, but the nonlinear terms are generally much smaller, with the primary exception being over the Iberian peninsula. Friction is much stronger in CAM3. As evidence, nearly all wavelengths (including the longest planetary waves) have smaller amplitude in CAM3 than in ERA-40 vorticity data. Negative near surface vorticity tendency bias on the European side of the Arctic is linked to the NAST track error (evident in the divergence term). CAM3 misses the Beaufort high in sea level pressure (SLP) due to low level warm temperature bias, too little vortex compression, and to too little horizontal advection of negative vorticity compared with ERA-40. Generally lower SLP values in CAM3 over the entire Arctic follow from lower level warm bias in CAM3. (orig.)

  7. Determinants and outcomes of acute transcatheter valve-in-valve therapy or embolization: a study of multiple valve implants in the U.S. PARTNER trial (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve).

    Science.gov (United States)

    Makkar, Raj R; Jilaihawi, Hasan; Chakravarty, Tarun; Fontana, Gregory P; Kapadia, Samir; Babaliaros, Vasilis; Cheng, Wen; Thourani, Vinod H; Bavaria, Joseph; Svensson, Lars; Kodali, Susheel; Shiota, Takahiro; Siegel, Robert; Tuzcu, E Murat; Xu, Ke; Hahn, Rebecca T; Herrmann, Howard C; Reisman, Mark; Whisenant, Brian; Lim, Scott; Beohar, Nirat; Mack, Michael; Teirstein, Paul; Rihal, Charanjit; Douglas, Pamela S; Blackstone, Eugene; Pichard, Augusto; Webb, John G; Leon, Martin B

    2013-07-30

    This study investigated the determinants and outcomes of acute insertion of a second transcatheter prosthetic valve (TV) within the first (TV-in-TV) or transcatheter valve embolization (TVE) after transcatheter aortic valve replacement (TAVR). TAVR failure can occur with both TV-in-TV and TVE as a consequence of TAVR malpositioning. Only case reports and limited series pertaining to these complications have been reported to date. Patients undergoing TAVR in the PARTNER (Placement of AoRTic TraNscathetER Valve Trial Edwards SAPIEN Transcatheter Heart Valve) randomized trial (cohorts A and B) and accompanying registries were studied. Data were dichotomized for those with and without TV-in-TV or TVE, respectively. From a total of 2,554 consecutive patients, 63 (2.47%) underwent TV-in-TV and 26 (1.01%) TVE. The indication for TV-in-TV was significant aortic regurgitation in most patients, often due not only to malpositioning but also to leaflet dysfunction. Despite similar aortic valve function on follow-up echoes, TV-in-TV was an independent predictor of 1-year cardiovascular mortality (hazard ratio [HR]: 1.86, 95% confidence interval [CI]: 1.03 to 3.38, p = 0.041), with a nonsignificant trend toward greater all-cause mortality (HR: 1.43, 95% CI: 0.88 to 2.33, p = 0.15). Technical and anatomical reasons accounted for most cases of TVE. A multivariable analysis found TVE to be an independent predictor of 1-year mortality (HR: 2.68, 95% CI: 1.34 to 5.36, p = 0.0055) but not cardiovascular mortality (HR: 1.30, 95% CI: 0.48 to 3.52, p = 0.60). Acute TV-in-TV and TVE are serious sequelae of TAVR, often resulting in multiple valve implants. They carry an excess of mortality and are caused by anatomic and technical factors, which may be avoidable with judicious procedural planning. Copyright © 2013 American College of Cardiology Foundation. Published by Elsevier Inc. All rights reserved.

  8. Screening for retinopathy of prematurity-a comparison between binocular indirect ophthalmoscopy and RetCam 120

    Directory of Open Access Journals (Sweden)

    Shah Parag

    2006-01-01

    Full Text Available Aim: To compare the photographic screening for retinopathy of prematurity (ROP using RetCam 120 with binocular indirect ophthalmoscope (BIO, which is the current gold standard. Setting and Design: Prospective, comparative study. Materials and Methods: A total of 87 RetCam examinations were performed on 27 premature babies. They were stored in a separate file after deleting the identifying information. At the same visit using the BIO with scleral depression, an experienced vitreoretinal surgeon evaluated the fundus in detail. A masked examiner then evaluated the RetCam photographs for presence or absence of ROP, the stage and zone of the disease, and the presence or absence of plus disease. These data were then compared with the BIO findings to determine the sensitivity, specificity, and the positive and negative predictive values of the method. Results: ROP was detected in 63 of 87 examinations by BIO and in 56 of 87 RetCam examinations. Nine RetCam examinations were false-negative and two were false-positive. Sensitivity of RetCam was 85.71% (54/63 and specificity was 91.66% (22/24. The positive and negative predictive values were 96.43% and 70.97% respectively. Conclusion: Nine cases having ROP were missed by the RetCam. All these cases were either in zone 3 or the outer part of zone 2, which later regressed. These were missed mostly because of the restricted mobility of the camera head caused by its size and the barrier caused by the lid speculum arms. No case of threshold ROP was missed. RetCam may replace BIO for screening of ROP.

  9. Performance of balanced bellows safety relief valves

    International Nuclear Information System (INIS)

    Lai, Y.S.

    1992-01-01

    By the nature of its design, the set point and lift of a conventional spring loaded safety relief valve are sensitive to back pressure. One way to reduce the adverse effects of the back pressure on the safety relief valve function is to install a balanced bellows in a safety relief valve. The metallic bellows has a rather wide range of manufacturing tolerance which makes the design of the bellows safety relief valve very complicated. The state-of-the-art balanced bellows safety relief valve can only substantially minimize, but cannot totally eliminate the back pressure effects on its set point and relieving capacity. Set point change is a linear function of the back pressure to the set pressure ratio. Depending on the valve design, the set point correction factor can be either greater or smaller than unity. There exists an allowable back pressure and critical back pressure for each safety relief valve. When total back pressure exceeds the R a , the relieving capacity will be reduced mainly resulting from the valve lift being reduced by the back pressure and the capacity reduction factor should be applied in valve sizing. Once the R c is exceeded, the safety relief valve becomes unstable and loses its over pressure protection capability. The capacity reduction factor is a function of system overpressure, but their relationship is non-linear in nature. (orig.)

  10. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  11. Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção? Transcatheter aortic valve-in-valve implantation: a selection change?

    Directory of Open Access Journals (Sweden)

    Diego Felipe Gaia

    2012-09-01

    Full Text Available INTRODUÇÃO: A reoperação para substituição de biopróteses aórticas com disfunção é procedimento que envolve considerável risco. Em alguns casos, a mortalidade é elevada e pode contraindicar o procedimento. O implante minimamente invasivo "valve-in-valve" transcateter de valva aórtica parece ser uma alternativa, reduzindo morbimortalidade. O objetivo deste estudo foi avaliar esses implantes utilizando a prótese Braile Inovare. MÉTODOS: A prótese Braile Inovare, transcateter, balão expansível foi utilizada em 14 casos. Euroscore médio foi de 42,9%. Todos os pacientes eram portadores de dupla disfunção de bioprótese aórtica. Os procedimentos foram realizados em ambiente cirúrgico híbrido, sob controle ecocardiográfico e fluoroscópico. Por meio de minitoracotomia esquerda, as próteses foram implantadas através do ápice ventricular, sob estimulação ventricular de alta frequência. Foram realizados controles clínicos e ecocardiográficos seriados. O seguimento variou de 1 a 30 meses. RESULTADOS: A correta liberação protética foi possível em todos os casos. Não ocorreu conversão. Não houve mortalidade operatória. A mortalidade em 30 dias foi de 14,3% (dois casos. A fração de ejeção apresentou aumento significativo após o 7º pós-operatório e o gradiente aórtico apresentou redução significativa. A insuficiência aórtica residual não esteve presente. Não ocorreu complicação vascular periférica ou bloqueio atrioventricular total. CONCLUSÕES: O implante "valve-in-valve" de valva aórtica transcateter em biopróteses com disfunção é um procedimento seguro e com morbimortalidade baixa. Essa possibilidade poderá alterar a indicação de seleção de prótese no procedimento inicial, favorecendo próteses biológicas.OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure

  12. [Ahmed valve in glaucoma surgery].

    Science.gov (United States)

    Bikbov, M M; Khusnitdinov, I I

    This is a review on Ahmed valve application in glaucoma surgery. It contains, in particular, data on the Ahmed valve efficiency, results of experimental and histological studies of filtering bleb encapsulation, examines the use of antimetabolites and anti-VEGF agents, and discusses implantation techniques. The current appraisal of antimetabolites delivery systems integrated into the Ahmed valve is presented. Various complications encountered in practice and preventive measures are also covered.

  13. GIANT PROSTHETIC VALVE THROMBUS

    Directory of Open Access Journals (Sweden)

    Prashanth Kumar

    2015-04-01

    Full Text Available Mechanical prosthetic valves are predisposed to bleeding, thrombosis & thromboembolic complications. Overall incidence of thromboembolic complications is 1% per year who are on oral anticoagulants, whereas bleeding complications incidence is 0.5% to 6.6% per year. 1, 2 Minimization of Scylla of thromboembolic & Charybdis of bleeding complication needs a balancing act of optimal antithrombotic therapy. We are reporting a case of middle aged male patient with prosthetic mitral valve presenting in heart failure. Patient had discontinued anticoagulants, as he had subdural hematoma in the past. He presented to our institute with a giant prosthetic valve thrombus.

  14. Estudo anatômico do terço proximal do fêmur: impacto femoroacetabular e o efeito cam Anatomic study of the proximal third of the femur: femoroacetabular impact and the cam effect

    Directory of Open Access Journals (Sweden)

    Pedro José Labronici

    2009-04-01

    Full Text Available OBJETIVO: Analisar as varia��ões anatômicas da extremidade proximal do fêmur que pudessem desenvolver o impacto femoroacetabular. MÉTODOS: Foram utilizados 199 espécimes anatômicos de fêmures esqueleticamente maduros. Os fêmures foram medidos para determinar o ângulo da anteversão do colo femoral, ângulo cervicodiafisário, esfericidade da cabeça femoral em ântero-posterior e súpero-inferior, ângulo entre a epífise e o colo femoral anterior, ângulo entre a epífise e o colo em perfil, distância em ântero-posterior a 5mm da junção cabeça e colo e distância em ântero-posterior da base do colo. RESULTADOS: Observou-se que o subgrupo com impacto apresentou diâmetro da junção a 5mm (p = 0,0001 e cam-cabeça (% (p = 0,0001 significativamente maiores e base-cam (% (p = 0,0001 significativamente menor que o subgrupo sem impacto. Identificou-se que cam-cabeça (% > 80 e base-cam (% OBJECTIVE: to analyze anatomical variations of the proximal end of femur that could cause a femoroacetabular impact. METHODS: 199 skeletically mature anatomical specimens of femurs were used. The femurs were measured in order to determine the anteversion angle of the femoral neck, neckshaft angle, sphericity of the femoral head at anteroposterior and superoinferior, angle between epiphysis and the anterior femoral neck, angle between epiphysis and the neck at lateral plane, anteroposterior distance at 5mm of the head and neck junction and anteroposterior distance of the neck base. RESULTS: we found that the impact subgroup presented a significantly larger junction diameter of 5mm (p = 0.0001 and cam-head (% (p= 0.0001, while base-cam (% (p = 0.0001 showed a significantly smaller diameter than the subgroup without impact. It was identified that cam-head (% > 80 e base-cam (% < 73 were identified as the optimal impact points. CONCLUSION: our study showed that the effect cam, caused by anatomical variations of the proximal femoral end focused the

  15. Machinability of CAD-CAM materials.

    Science.gov (United States)

    Chavali, Ramakiran; Nejat, Amir H; Lawson, Nathaniel C

    2017-08-01

    Although new materials are available for computer-aided design and computer-aided manufacturing (CAD-CAM) fabrication, limited information is available regarding their machinability. The depth of penetration of a milling tool into a material during a timed milling cycle may indicate its machinability. The purpose of this in vitro study was to compare the tool penetration rate for 2 polymer-containing CAD-CAM materials (Lava Ultimate and Enamic) and 2 ceramic-based CAD-CAM materials (e.max CAD and Celtra Duo). The materials were sectioned into 4-mm-thick specimens (n=5/material) and polished with 320-grit SiC paper. Each specimen was loaded into a custom milling apparatus. The apparatus pushed the specimens against a milling tool (E4D Tapered 2016000) rotating at 40 000 RPM with a constant force of 0.98 N. After a 6-minute timed milling cycle, the length of each milling cut was measured with image analysis software under a digital light microscope. Representative specimens and milling tools were examined with scanning electron microscopy (SEM) and energy dispersive x-ray spectroscopy. The penetration rate of Lava Ultimate (3.21 ±0.46 mm/min) and Enamic (2.53 ±0.57 mm/min) was significantly greater than that of e.max CAD (1.12 ±0.32 mm/min) or Celtra Duo (0.80 ±0.21 mm/min) materials. SEM observations showed little tool damage, regardless of material type. Residual material was found on the tools used with polymer-containing materials, and wear of the embedding medium was seen on the tools used with the ceramic-based materials. Edge chipping was noted on cuts made in the ceramic-based materials. Lava Ultimate and Enamic have greater machinability and less edge chipping than e.max CAD and Celtra Duo. Copyright © 2016 Editorial Council for the Journal of Prosthetic Dentistry. Published by Elsevier Inc. All rights reserved.

  16. Bicuspid aortic valves: Diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, David J., E-mail: david.murphy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); McEvoy, Sinead H., E-mail: s.mcevoy@st-vincents.ie [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland); Iyengar, Sri, E-mail: sri.iyengar@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Feuchtner, Gudrun, E-mail: Gudrun.Feuchtner@i-med.ac.at [Department of Radiology, Innsbruck Medical University, Anichstr. 35, A-6020 Innsbruck (Austria); Cury, Ricardo C., E-mail: r.cury@baptisthealth.net [Department of Radiology, Baptist Cardiac and Vascular Institute, 8900 North Kendall Drive, Miami, FL 33176 (United States); Roobottom, Carl, E-mail: carl.roobottom@nhs.net [Department of Radiology, Plymouth Hospitals NHS Trust, Plymouth Devon PL6 8DH (United Kingdom); Plymouth University Peninsula Schools of Medicine and Dentistry (United Kingdom); Baumueller, Stephan, E-mail: Hatem.Alkadhi@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Alkadhi, Hatem, E-mail: stephan.baumueller@usz.ch [Institute for Diagnostic and Interventional Radiology, University Hospital Zurich, Raemistrasse 100, CH-8091 Zurich (Switzerland); Dodd, Jonathan D., E-mail: jonniedodd@gmail.com [Department of Radiology, St Vincent' s University Hospital, Elm Park, Dublin 4 (Ireland)

    2014-08-15

    Objectives: To assess the diagnostic accuracy of standard axial 64-slice chest CT compared to aortic valve image plane ECG-gated cardiac CT for bicuspid aortic valves. Materials and methods: The standard axial chest CT scans of 20 patients with known bicuspid aortic valves were blindly, randomly analyzed for (i) the appearance of the valve cusps, (ii) the largest aortic sinus area, (iii) the longest aortic cusp length, (iv) the thickest aortic valve cusp and (v) valve calcification. A second blinded reader independently analyzed the appearance of the valve cusps. Forty-two age- and sex-matched patients with known tricuspid aortic valves were used as controls. Retrospectively ECG-gated cardiac CT multiphase reconstructions of the aortic valve were used as the gold-standard. Results: Fourteen (21%) scans were scored as unevaluable (7 bicuspid, 7 tricuspid). Of the remainder, there were 13 evaluable bicuspid valves, ten of which showed an aortic valve line sign, while the remaining three showed a normal Mercedes-Benz appearance owing to fused valve cusps. The 35 evaluable tricuspid aortic valves all showed a normal Mercedes-Benz appearance (P = 0.001). Kappa analysis = 0.62 indicating good interobserver agreement for the aortic valve cusp appearance. Aortic sinus areas, aortic cusp lengths and aortic cusp thicknesses of ≥3.8 cm{sup 2}, 3.2 cm and 1.6 mm respectively on standard axial chest CT best distinguished bicuspid from tricuspid aortic valves (P < 0.0001 for all). Of evaluable scans, the sensitivity, specificity, positive and negative predictive values of standard axial chest CT in diagnosing bicuspid aortic valves was 77% (CI 0.54–1.0), 100%, 100% and 70% respectively. Conclusion: The aortic valve is evaluable in approximately 80% of standard chest 64-slice CT scans. Bicuspid aortic valves may be diagnosed on evaluable scans with good diagnostic accuracy. An aortic valve line sign, enlarged aortic sinuses and elongated, thickened valve cusps are specific CT

  17. Minimally invasive aortic valve replacement

    DEFF Research Database (Denmark)

    Foghsgaard, Signe; Schmidt, Thomas Andersen; Kjaergard, Henrik K

    2009-01-01

    In this descriptive prospective study, we evaluate the outcomes of surgery in 98 patients who were scheduled to undergo minimally invasive aortic valve replacement. These patients were compared with a group of 50 patients who underwent scheduled aortic valve replacement through a full sternotomy...... operations were completed as mini-sternotomies, 4 died later of noncardiac causes. The aortic cross-clamp and perfusion times were significantly different across all groups (P replacement...... is an excellent operation in selected patients, but its true advantages over conventional aortic valve replacement (other than a smaller scar) await evaluation by means of randomized clinical trial. The "extended mini-aortic valve replacement" operation, on the other hand, is a risky procedure that should...

  18. A Space Cam Mechanism for Power Transmission of an Opposite-cylinder Piston Engine

    Directory of Open Access Journals (Sweden)

    Zhang Haoyue

    2015-01-01

    Full Text Available For the purpose of improving the engine’s power density, we put forward a new type of power transmission mechanism which is used for opposed-cylinder engine. The gas pressure acts on the cam through the piston and push rod, and the spindle rotation of external is driven by the cam. The design of spatial cam work surface is completed by using the enveloping theory of a family of space curves, the force between roller and cam is analyzed using dynamic analysis software. Under the condition of equal number, size and stroke of piston, the new one with larger power density is more compact in structure than the traditional power transmission mechanism, and the reaction force on either side of the main shaft and the acting force between pistons and cylinders are smaller than those in traditional one, which prolongs the service life of the pistons.

  19. MEMS Micro-Valve for Space Applications

    Science.gov (United States)

    Chakraborty, I.; Tang, W. C.; Bame, D. P.; Tang, T. K.

    1998-01-01

    We report on the development of a Micro-ElectroMechanical Systems (MEMS) valve that is designed to meet the rigorous performance requirements for a variety of space applications, such as micropropulsion, in-situ chemical analysis of other planets, or micro-fluidics experiments in micro-gravity. These systems often require very small yet reliable silicon valves with extremely low leak rates and long shelf lives. Also, they must survive the perils of space travel, which include unstoppable radiation, monumental shock and vibration forces, as well as extreme variations in temperature. Currently, no commercial MEMS valve meets these requirements. We at JPL are developing a piezoelectric MEMS valve that attempts to address the unique problem of space. We begin with proven configurations that may seem familiar. However, we have implemented some major design innovations that should produce a superior valve. The JPL micro-valve is expected to have an extremely low leak rate, limited susceptibility to particulates, vibration or radiation, as well as a wide operational temperature range.

  20. Radiological visualization of prosthetic heart valves in situ

    International Nuclear Information System (INIS)

    Hoffmeister, H.M.; Pirschel, J.

    1986-01-01

    To determine the radiographic appearance of prosthetic heart valves 15 different models were investigated in situ. Fluoroscopy with detail radiographs and standard chest-radiographs were used for identification of the specific type of the prosthesis, for determination of details of the valve apparatus and for evaluation of the motion of the valve disc/ball. - Fluoroscopy and routine radiographs provided sufficient information to identify all prosthetic heart valves with exception of the Xenomedica bioprosthesis. If radiopaque material was used for the valve disc/ball, fluoroscopic assessment of the function of the valve was possible. Thus, in most types of disc or ball valves the opening/closing of the valve can be visualized, whereas in bioprosthesis a radiological determination of the mechanical function is not possible. (orig.) [de