WorldWideScience

Sample records for valve actuating sleeve

  1. Drive piston assembly for a valve actuator assembly

    Science.gov (United States)

    Sun, Zongxuan

    2010-02-23

    A drive piston assembly is provided that is operable to selectively open a poppet valve. The drive piston assembly includes a cartridge defining a generally stepped bore. A drive piston is movable within the generally stepped bore and a boost sleeve is coaxially disposed with respect to the drive piston. A main fluid chamber is at least partially defined by the generally stepped bore, drive piston, and boost sleeve. First and second feedback chambers are at least partially defined by the drive piston and each are disposed at opposite ends of the drive piston. At least one of the drive piston and the boost sleeve is sufficiently configured to move within the generally stepped bore in response to fluid pressure within the main fluid chamber to selectively open the poppet valve. A valve actuator assembly and engine are also provided incorporating the disclosed drive piston assembly.

  2. Sleeve Muscle Actuator and Its Application in Transtibial Prostheses

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2014-01-01

    This paper describes the concept of a new sleeve muscle actuator, and a transtibial prosthesis design powered by this novel actuator. Inspired by the functioning mechanism of the traditional pneumatic muscle actuator, the sleeve muscle actuator incorporates a cylindrical insert to the center of the pneumatic muscle, which eliminates the central portion of the internal volume. As a result of this change, the sleeve muscle provides multiple advantages over the traditional pneumatic muscle, including the increased force capacity over the entire range of motion, reduced energy consumption, and faster dynamic response. Furthermore, utilizing the load-bearing tube as the insert, the sleeve muscle enables an innovative “actuation-load bearing” structure, which has a potential of generating a highly compact actuation system suitable for prosthetic use. Utilizing this new actuator, the preliminary design of a transtibial prosthesis is presented, which is able to provide sufficient torque output and range of motion for a 75 Kg amputee user in level walking. PMID:24187262

  3. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems

    Directory of Open Access Journals (Sweden)

    Hao Zheng

    2013-11-01

    Full Text Available This paper presents a new type of muscle-like actuator, namely double-acting (DA sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc.. Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability.

  4. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2014-01-01

    This paper presents a new type of muscle-like actuator, namely double-acting (DA) sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc.). Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability. PMID:25264492

  5. Double-Acting Sleeve Muscle Actuator for Bio-Robotic Systems.

    Science.gov (United States)

    Zheng, Hao; Shen, Xiangrong

    2013-11-25

    This paper presents a new type of muscle-like actuator, namely double-acting (DA) sleeve muscle actuator, which is suitable for the actuation of biologically-inspired and biomedical robotic systems, especially those serving human-assistance purposes (prostheses, orthoses, etc .). Developed based on the traditional pneumatic muscle actuator, the new DA sleeve muscle incorporates a unique insert at the center. With the insert occupying the central portion of the internal volume, this new actuator enjoys multiple advantages relative to the traditional pneumatic muscle, including a consistent increase of force capacity over the entire range of motion, and a significant decrease of energy consumption in operation. Furthermore, the insert encompasses an additional chamber, which generates an extension force when pressurized. As such, this new actuator provides a unique bi-directional actuation capability, and, thus, has a potential to significantly simplify the design of a muscle actuator-powered robotic system. To demonstrate this new actuator concept, a prototype has been designed and fabricated, and experiments conducted on this prototype demonstrated the enhanced force capacity and the unique bi-directional actuation capability.

  6. Design of a Soft Robotic Elbow Sleeve with Passive and Intent-Controlled Actuation

    Directory of Open Access Journals (Sweden)

    Tze Hui Koh

    2017-10-01

    Full Text Available The provision of continuous passive, and intent-based assisted movements for neuromuscular training can be incorporated into a robotic elbow sleeve. The objective of this study is to propose the design and test the functionality of a soft robotic elbow sleeve in assisting flexion and extension of the elbow, both passively and using intent-based motion reinforcement. First, the elbow sleeve was developed, using elastomeric and fabric-based pneumatic actuators, which are soft and lightweight, in order to address issues of non-portability and poor alignment with joints that conventional robotic rehabilitation devices are faced with. Second, the control system was developed to allow for: (i continuous passive actuation, in which the actuators will be activated in cycles, alternating between flexion and extension; and (ii an intent-based actuation, in which user intent is detected by surface electromyography (sEMG sensors attached to the biceps and triceps, and passed through a logic sequence to allow for flexion or extension of the elbow. Using this setup, the elbow sleeve was tested on six healthy subjects to assess the functionality of the device, in terms of the range of motion afforded by the device while in the continuous passive actuation. The results showed that the elbow sleeve is capable of achieving approximately 50% of the full range of motion of the elbow joint among all subjects. Next, further experiments were conducted to test the efficacy of the intent-based actuation on these healthy subjects. The results showed that all subjects were capable of achieving electromyography (EMG control of the elbow sleeve. These preliminary results show that the elbow sleeve is capable of carrying out continuous passive and intent-based assisted movements. Further investigation of the clinical implementation of the elbow sleeve for the neuromuscular training of neurologically-impaired persons, such as stroke survivors, is needed.

  7. Scissor thrust valve actuator

    Science.gov (United States)

    DeWall, Kevin G.; Watkins, John C; Nitzel, Michael E.

    2006-08-29

    Apparatus for actuating a valve includes a support frame and at least one valve driving linkage arm, one end of which is rotatably connected to a valve stem of the valve and the other end of which is rotatably connected to a screw block. A motor connected to the frame is operatively connected to a motor driven shaft which is in threaded screw driving relationship with the screw block. The motor rotates the motor driven shaft which drives translational movement of the screw block which drives rotatable movement of the valve driving linkage arm which drives translational movement of the valve stem. The valve actuator may further include a sensory control element disposed in operative relationship with the valve stem, the sensory control element being adapted to provide control over the position of the valve stem by at least sensing the travel and/or position of the valve stem.

  8. Qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1981-01-01

    This Standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. It may also be used to separately qualify actuator components. This Standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  9. Dielectric elastomer actuators used for pneumatic valve technology

    International Nuclear Information System (INIS)

    Giousouf, Metin; Kovacs, Gabor

    2013-01-01

    Dielectric elastomer actuators have been investigated for applications in the field of pneumatic automation technology. We have developed different valve designs with stacked dielectric elastomer actuators and with integrated high voltage converters. The actuators were made using VHB-4910 material and a stacker machine for automated fabrication of the cylindrical actuators. Typical characteristics of pneumatic valves such as flow rate, power consumption and dynamic behaviour are presented. For valve construction the force and stroke parameters of the dielectric elastomer actuator have been measured. Further, benefits for valve applications using dielectric elastomers are shown as well as their potential operational area. Finally, challenges are discussed that are relevant for the use of elastomer actuators in valves for industrial applications. (paper)

  10. Actuation and Control of a Micro Electrohydraulic Digital Servo Valve

    Energy Technology Data Exchange (ETDEWEB)

    Yu, Z Q; Hu, M J; Pei, X; Ruan, J [MOE Key Laboratory of Mechanical Manufacture and Automation Zhejiang University of Technology, 310014 (China)

    2006-10-15

    Structure of the micro digital servo valve is given. A micro stepper motor is used as electrical-to-mechanical interface of the valve. A special mechanical device is designed to convert the rotation of the stepper motor into the linear motion of the spool. This moving conversion device functions through an eccentric ball head rigidly connected to the axis of the stepper motor and plugged into a slot at the central spool land. While the stepper motor rotates, the eccentric ball head will actuate the spool to make a linear motion. Unlike conventional servo or proportional valves, in which the spool is forced to central position by a spring force, when the current supply is switched off, the digital valve has a program to control the spool to its central position each time the electrical power supply is switched on or off. The two end screws are used to adjust the position of the sleeve to sustain a mechanical central position coincided with electrical central position given by the stepper motor after initialization. The adjustment has to be carried once before the first time the servo valve is put into service. This paper presents theoretical analysis and experimental study of dynamic characteristics of the proposed micro digital servo valve. Experimental results demonstrated that the valve takes the advantage of high accuracy and fast response.

  11. Actuation and Control of a Micro Electrohydraulic Digital Servo Valve

    International Nuclear Information System (INIS)

    Yu, Z Q; Hu, M J; Pei, X; Ruan, J

    2006-01-01

    Structure of the micro digital servo valve is given. A micro stepper motor is used as electrical-to-mechanical interface of the valve. A special mechanical device is designed to convert the rotation of the stepper motor into the linear motion of the spool. This moving conversion device functions through an eccentric ball head rigidly connected to the axis of the stepper motor and plugged into a slot at the central spool land. While the stepper motor rotates, the eccentric ball head will actuate the spool to make a linear motion. Unlike conventional servo or proportional valves, in which the spool is forced to central position by a spring force, when the current supply is switched off, the digital valve has a program to control the spool to its central position each time the electrical power supply is switched on or off. The two end screws are used to adjust the position of the sleeve to sustain a mechanical central position coincided with electrical central position given by the stepper motor after initialization. The adjustment has to be carried once before the first time the servo valve is put into service. This paper presents theoretical analysis and experimental study of dynamic characteristics of the proposed micro digital servo valve. Experimental results demonstrated that the valve takes the advantage of high accuracy and fast response

  12. Fast-acting valve actuator

    Science.gov (United States)

    Cho, Nakwon

    1980-01-01

    A fast-acting valve actuator utilizes a spring driven pneumatically loaded piston to drive a valve gate. Rapid exhaust of pressurized gas from the pneumatically loaded side of the piston facilitates an extremely rapid piston stroke. A flexible selector diaphragm opens and closes an exhaust port in response to pressure differentials created by energizing and de-energizing a solenoid which controls the pneumatic input to the actuator as well as selectively providing a venting action to one side of the selector diaphragm.

  13. Worchester Solenoid Actuated Gas Operated MCO Isolation Valves

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    These valves are 1 inch gas-operated full-port ball valves incorporating a solenoid and limit switches as integral parts of the actuator that are used in process streams within the CVDF hood. The valves fail closed (on loss of pressure or electrical) to prevent MCO vent drain to either reduce air in-leakage or loss of He. The valves have couplings for transverse actuator mounting

  14. Worcester Solenoid-Actuated Gas Operated MCO Isolation Valves

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    These valves are 1 inch gas-operated full-port ball valves incorporating a solenoid and limit switches as Integral parts of the actuator that are used in different process streams within the CVDF hood. The valves fail closed (on loss of pressure or electrical) for MCO isolation to either reduce air in leakage or loss of He. All valves have coupling for transverse actuator mounting

  15. Crimped braided sleeves for soft, actuating arm in robotic abdominal surgery.

    Science.gov (United States)

    Elsayed, Yahya; Lekakou, Constantina; Ranzani, Tommaso; Cianchetti, Matteo; Morino, Mario; Arezzo, Alberto; Menciassi, Arianna; Geng, Tao; Saaj, Chakravarthini M

    2015-01-01

    This paper investigates different types of crimped, braided sleeve used for a soft arm for robotic abdominal surgery, with the sleeve required to contain balloon expansion in the pneumatically actuating arm while it follows the required bending, elongation and diameter reduction of the arm. Three types of crimped, braided sleeves from PET (BraidPET) or nylon (BraidGreyNylon and BraidNylon, with different monofilament diameters) were fabricated and tested including geometrical and microstructural characterisation of the crimp and braid, mechanical tests and medical scratching tests for organ damage of domestic pigs. BraidPET caused some organ damage, sliding under normal force of 2-5 N; this was attributed to the high roughness of the braid pattern, the higher friction coefficient of polyethylene terephthalate (PET) compared to nylon, and the high frequency of the crimp peaks for this sleeve. No organ damage was observed for the BraidNylon, attributed to both the lower roughness of the braid pattern and the low friction coefficient of nylon. BraidNylon also required the lowest tensile force during its elongation to similar maximum strain as that of BraidPET, translating to low power requirements. BraidNylon is recommended for the crimped sleeve of the arm designed for robotic abdominal surgery.

  16. Engine including hydraulically actuated valvetrain and method of valve overlap control

    Science.gov (United States)

    Cowgill, Joel [White Lake, MI

    2012-05-08

    An exhaust valve control method may include displacing an exhaust valve in communication with the combustion chamber of an engine to an open position using a hydraulic exhaust valve actuation system and returning the exhaust valve to a closed position using the hydraulic exhaust valve actuation assembly. During closing, the exhaust valve may be displaced for a first duration from the open position to an intermediate closing position at a first velocity by operating the hydraulic exhaust valve actuation assembly in a first mode. The exhaust valve may be displaced for a second duration greater than the first duration from the intermediate closing position to a fully closed position at a second velocity at least eighty percent less than the first velocity by operating the hydraulic exhaust valve actuation assembly in a second mode.

  17. Modified Sleeve Technique in Aortic Valve-Sparing Operation for Marfan Syndrome.

    Science.gov (United States)

    Wu, Yung-Szu; Hsieh, Shih-Rong; Wang, Chung-Chi; Tsai, Chung-Lin

    2018-03-22

    We devised a simple modification of the Florida Sleeve procedure to perform aortic valve-sparing surgery. This technique is simple, quick, effective, and safe. We used this technique in operations performed on two young patients with Marfan syndrome. The initial and short-term results were satisfactory.

  18. Early and medium term results of the sleeve valve-sparing procedure for aortic root ectasia.

    Science.gov (United States)

    Gamba, Amando; Tasca, Giordano; Giannico, Floriana; Lobiati, Elisabetta; Skouse, Douglas; Galanti, Andrea; Martino, Antonello Stefano; Triggiani, Michele

    2015-04-01

    The aim of this retrospective study was to evaluate our experience of using a simplified aortic valve sleeve procedure to treat aortic root ectasia and aneurysms with or without aortic regurgitation. In experienced hands, 2 aortic valve-sparing procedures, ie, Yacoub and David, have yielded excellent long-term results in the treatment of aortic root aneurysms, with or without aortic regurgitation. However, these techniques are demanding and not widely used. Recently, a new and simplified valve-sparing technique, named "sleeve procedure," has been proposed, and has yielded encouraging early results. Ninety consecutive patients with aortic root aneurysms underwent sleeve procedures from October 2006 to October 2012. Follow-up data (clinical 100% complete and echocardiographic 93% complete) were acquired from our outpatient clinic or from the referring cardiologist. The mean age of the patients was 61.5 ± 12.5 years, 79% were male, 16 (18%) had a bicuspid valve, 3 had Marfan syndrome, and 2 had aortic dissection. Over a mean clinical follow-up of 34 ± 19 months, 2 patients died from noncardiac causes and 1 was reoperated on for the recurrence of aortic regurgitation. On follow-up echocardiography after a mean of 18 ± 9 months, aortic regurgitation was absent/negligible, mild or moderate in 62%, 37%, and 1% of patients, respectively, and the diameters of the annulus, Valsalva sinuses, and sinotubular junction were 27.3 + 2.2, 37.0 + 3.4, and 30.6 + 3.1 mm, respectively. Our encouraging early and medium term results suggest that the sleeve procedure is a safe and effective aortic valve-sparing technique for the treatment of aortic root ectasia and aneurysm. However, longer follow-up is needed in order to draw definitive conclusions. Copyright © 2015 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  19. Self-actuated Polymeric Valve for Autonomous Sensing and Mixing

    DEFF Research Database (Denmark)

    Häfliger, Daniel; Marie, Rodolphe Charly Willy; Boisen, Anja

    2005-01-01

    We present an autonomously operated microvalve array for chemical sensing and mixing, which gains the actuation energy from a chemical reaction on the valve structure. An 8-μm-thick flapper valve made in SU-8 is coated with stress-loaded Al on one side and Ti on the other side. The metal films ke...... a reservoir. Calculations reveal that valve operation with stress originating from biochemical processes will require considerable enhancement of the actuation efficiency.......We present an autonomously operated microvalve array for chemical sensing and mixing, which gains the actuation energy from a chemical reaction on the valve structure. An 8-μm-thick flapper valve made in SU-8 is coated with stress-loaded Al on one side and Ti on the other side. The metal films keep...

  20. Pressure control valve using proportional electro-magnetic solenoid actuator

    International Nuclear Information System (INIS)

    Yun, So Nam; Ham, Young Bog; Park, Pyoung Won

    2006-01-01

    This paper presents an experimental characteristics of electro-hydraulic proportional pressure control valve. In this study, poppet and valve body which are assembled into the proportional solenoid were designed and manufactured. The constant force characteristics of proportional solenoid actuator in the control region should be independent of the plunger position in order to be used to control the valve position in the fluid flow control system. The stroke-force characteristics of the proportional solenoid actuator is determined by the shape (or parameters) of the control cone. In this paper, steady state and transient characteristics of the solenoid actuator for electro-hydraulic proportional valve are analyzed using finite element method and it is confirmed that the proportional solenoid actuator has a constant attraction force in the control region independently on the stroke position. The effects of the parameters such as control cone length, thickness and taper length are also discussed

  1. One-shot valve may be remotely actuated

    Science.gov (United States)

    Kami, S.

    1965-01-01

    One-shot valve, with spring-loaded plunger and sealing diaphragm, incorporates an emergency release actuated by a remote sensor. The plunger is released by the electrical melting of a fuse link and pierces the valve seal. The valve lowers fluid pressure in a container without losing the contained fluid.

  2. DEAP actuator and its high voltage driver for heating valve application

    DEFF Research Database (Denmark)

    Huang, Lina; Nørmølle, L. F.; Sarban, R.

    2014-01-01

    Due to the advantages of DEAP (Dielectric Electro Active Polymer) material, such as light weight, noise free operation, high energy and power density and fast response speed, it can be applied in a variety of applications to replace the conventional transducers or actuators. This paper introduces...... DEAP actuator to the heating valve system and conducts a case study to discuss the feasible solution in designing DEAP actuator and its driver for heating valve application. First of all, the heating valves under study are briefly introduced. Then the design and the development for DEAP actuator...... is illustrated in detail, and followed by the detailed investigation of the HV driver for DEAP actuator. In order to verify the implementation, the experimental measurements are carried out for DEAP actuator, its HV driver as well as the entire heating valve system....

  3. Modeling and Investigation of Electromechanical Valve Train Actuator at simulated Pressure conditions

    DEFF Research Database (Denmark)

    Habib, Tufail

    2012-01-01

    In an electromechanical valve actuated engine, the valves are driven by solenoid-type actuators and cam-shaft is eliminated. Control of each valve provides flexibility in valve timings over all engine conditions and achieves the benefits of variable valve timing(VVT). This paper is about investig...

  4. Designed pneumatic valve actuators for controlled droplet breakup and generation.

    Science.gov (United States)

    Choi, Jae-Hoon; Lee, Seung-Kon; Lim, Jong-Min; Yang, Seung-Man; Yi, Gi-Ra

    2010-02-21

    The dynamic breakup of emulsion droplets was demonstrated in double-layered microfluidic devices equipped with designed pneumatic actuators. Uniform emulsion droplets, produced by shearing at a T-junction, were broken into smaller droplets when they passed downstream through constrictions formed by a pneumatically actuated valve in the upper control layer. The valve-assisted droplet breakup was significantly affected by the shape and layout of the control valves on the emulsion flow channel. Interestingly, by actuating the pneumatic valve immediately above the T-junction, the sizes of the emulsion droplets were controlled precisely in a programmatic manner that produced arrays of uniform emulsion droplets in various sizes and dynamic patterns.

  5. Self-actuating and locking control for nuclear reactor

    International Nuclear Information System (INIS)

    Chung, D.K.

    1982-01-01

    A self-actuating, self-locking flow cutoff valve particularly suited for use in a nuclear reactor of the type which utilizes a plurality of fluid support neutron absorber elements to provide for the safe shutdown of the reactor. The valve comprises a substantially vertical elongated housing and an aperture plate located in the housing for the flow of fluid therethrough, a substantially vertical elongated nozzle member located in the housing and affixed to the housing with an opening in the bottom for receiving fluid and apertures adjacent a top end for discharging fluid. The nozzle further includes two sealing means, one located above and the other below the apertures. Also located in the housing and having walls surrounding the nozzle is a flow cutoff sleeve having a fluid opening adjacent an upper end of the sleeve, the sleeve being moveable between an upper open position wherein the nozzle apertures are substantially unobstructed and a closed position wherein the sleeve and nozzle sealing surfaces are mated such that the flow of fluid through the apertures is obstructed. It is a particular feature of the present invention that the valve further includes a means for utilizing any increase in fluid pressure to maintain the cutoff sleeve in a closed position. It is another feature of the invention that there is provided a means for automatically closing the valve whenever the flow of fluid drops below a predetermined level

  6. FEATURES OF CONTROLLING ELECTROPNEUMATIC VALVES OF ACTUATOR TO CONTROL ITS CLUTCH WITH ACCELERATION VALVE

    Directory of Open Access Journals (Sweden)

    O. A. Yaryta

    2018-01-01

    Full Text Available The article deals with one of the ways to control an actuator of the automated clutch control system. The aim is to design control of the electropneumatic actuator, to control its coupling with the acceleration valve on the basis of experimental research as well as to provide rational parameters of the automated clutch control system for the robotic transmission. The feature of the system is an acceleration valve in the design of the electropneumatic actuator to control the clutch. New links demand to adjust the way to control the actuator. The connection of Pulse-Width Modulation (PWM with single power supply pulses to control electropneumatic valves is substantiated. The quantitative characteristics of single control pulses and PWM ones are determined. The error of operation accuracy for various ways of the control of the electropneumatic actuator to control the clutch of the robotic transmission is determined. Obtained separate PWM area is designed to suppress the initial hysteresis when the rod of the clutch actuator is moved. An algorithm for the operation of a clutch control system is proposed, taking into account the use of two modes of operation of solenoid valves. A graphical interpretation of the clutch control algorithm is presented, which gives an idea of the location of the constant signal feeding zones to the solenoid valve, as well as the operation areas of the solenoid valve in PWM mode. The control algorithm of the clutch booster provides a mode of guaranteed absence of excess pressure in the pneumatic cylinder after releasing the clutch pedal, provided that two normally closed solenoid valves are used. This configuration of the electro-pneumatic clutch control system allows the use of an emergency clutch release system in case of voltage absence. The reference algorithm for filtering the array of data coming from the feedback sensor, as well as the numerical values of the delay caused by the presence of a filter, are given.

  7. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase II

    Data.gov (United States)

    National Aeronautics and Space Administration — Cryogenic fluid valves are subject to harsh exposure and actuators to drive these valves require robust performance and high reliability. DSM's piezoelectric...

  8. Development of Proportional Pressure Control Valve for Hydraulic Braking Actuator of Automobile ABS

    Directory of Open Access Journals (Sweden)

    Che-Pin Chen

    2018-04-01

    Full Text Available This research developed a novel proportional pressure control valve for an automobile hydraulic braking actuator. It also analyzed and simulated solenoid force of the control valves, and the pressure relief capability test of electromagnetic thrust with the proportional valve body. Considering the high controllability and ease of production, the driver of this proportional valve was designed with a small volume and powerful solenoid force to control braking pressure and flow. Since the proportional valve can have closed-loop control, the proportional valve can replace a conventional solenoid valve in current brake actuators. With the proportional valve controlling braking and pressure relief mode, it can narrow the space of hydraulic braking actuator, and precisely control braking force to achieve safety objectives. Finally, the proposed novel proportional pressure control valve of an automobile hydraulic braking actuator was implemented and verified experimentally.

  9. Torque characteristics of a 122-centimeter butterfly valve with a hydro/pneumatic actuator

    Science.gov (United States)

    Lin, F. N.; Moore, W. I.; Lundy, F. E.

    1981-01-01

    Actuating torque data from field testing of a 122-centimeter (48 in.) butterfly valve with a hydro/pneumatic actuator is presented. The hydraulic cylinder functions as either a forward or a reverse brake. Its resistance torque increases when the valve speeds up and decreases when the valve slows down. A reduction of flow resistance in the hydraulic flow path from one end of the hydraulic cylinder to the other will effectively reduce the hydraulic resistance torque and hence increase the actuating torque. The sum of hydrodynamic and friction torques (combined resistance torque) of a butterfly valve is a function of valve opening time. An increase in the pneumatic actuating pressure will result in a decrease in both the combined resistance torque and the actuator opening torque; however, it does shorten the valve opening time. As the pneumatic pressure increases, the valve opening time for a given configuration approaches an asymptotical value.

  10. OMS engine shutoff valve and actuation system design and evaluation. [for space shuttles

    Science.gov (United States)

    Wichmann, H.

    1974-01-01

    Shutoff valve and actuation system concepts that are most suitable for the Orbital Maneuvering Systems engine application were determined. Emphasis was placed on the ten year and 100 mission life requirement, propellant and propellant residue compatibility and weight. It was found that poppet or ball valves utilizing electric or electropneumatic actuation were most applicable. Preliminary design layouts of a number of valve and actuation concepts were prepared and analyzed to make the optimum concept selection. Pneumatic actuation systems were required to feature their own pneumatic supply so that for the quad redundant valve, it was necessary to include two pneumatic supply systems, one for each of the series legs of the quad redundant package. The requirement for the pneumatic package placed heavy reliability, weight, and maintenance penalties upon electropneumatic actuation systems. The two valve and actuation systems concepts selected featured electric torque motor operation and a poppet as well as a ball valve concept with a retractable seal.

  11. Design and Evaluation of a Direct Drive Valve Actuated by Piezostack Actuator

    Directory of Open Access Journals (Sweden)

    Juncheol Jeon

    2013-01-01

    Full Text Available This paper presents performance characteristics of a new type of direct drive valve (DDV system driven by a piezostack actuator. The flexible beam mechanism is employed to amplify the output displacement from the piezostack actuator. After describing the operational principle of the proposed piezo DDV system, the governing equation of the whole piezo DDV system is then obtained by integrating the equations of the valve components. Based on the proposed model, significant structural components of the piezo DDV system are designed in order to achieve operational requirements (operating frequency: over 100 Hz; flow rate: 20 liter/Min.. An optimal design method is proposed for obtaining the geometry of the flexible beam mechanism by considering spool displacement, required operating frequency, and available space of the valve. After deciding the specific geometric dimensions of the piezo DDV system, a PID control algorithm is designed to enforce the spool position to the desired position trajectories by activating the piezostack actuator. Characteristics and control performances of the proposed piezo DDV system are evaluated using the MATLAB Simulink.

  12. Regulatory control of nuclear facility valves and their actuators

    International Nuclear Information System (INIS)

    1993-01-01

    The methods and procedures by which the Finnish Centre for Radiation and Nuclear Safety (STUK) regulates valves and their actuators in nuclear power plants and in other nuclear facilities are specified in the guide. The scope of regulation depends on the Safety Class of the valve and the actuator in question. The Safety Classification principles for the systems, structures and components of the nuclear power plants are described in the guide YVL 2.1 and the regulatory control of the nuclear facility safety valves is described in the guide YVL 5.4

  13. Investigations on pneumatically forced-actuated compressor valves

    Science.gov (United States)

    Stöckel, Christian; Thomas, Christiane; Nickl, Jörg; Hesse, Ullrich

    2017-08-01

    In the present paper the performance of a novel designed valve for reciprocating piston machines is investigated, which makes existing compressors utilizable for operating as expander. Three design parameters were identified as critical for the valves performance particularly in forced actuated mode. Within a numerical simulation a study on the crucial geometrical parameters, the influence could be observed. Afterwards the experimental setup for the integral test of the valve design is presented and also additional tests for single valve components.

  14. Bistable (latching) solenoid actuated propellant isolation valve

    Science.gov (United States)

    Wichmann, H.; Deboi, H. H.

    1979-01-01

    The design, fabrication, assembly and test of a development configuration bistable (latching) solenoid actuated propellant isolation valve suitable for the control hydrazine and liquid fluorine to an 800 pound thrust rocket engine is described. The valve features a balanced poppet, utilizing metal bellows, a hard poppet/seat interface and a flexure support system for the internal moving components. This support system eliminates sliding surfaces, thereby rendering the valve free of self generated particles.

  15. A numerical insight into elastomer normally closed micro valve actuation with cohesive interfacial cracking modelling

    Science.gov (United States)

    Wang, Dongyang; Ba, Dechun; Hao, Ming; Duan, Qihui; Liu, Kun; Mei, Qi

    2018-05-01

    Pneumatic NC (normally closed) valves are widely used in high density microfluidics systems. To improve actuation reliability, the actuation pressure needs to be reduced. In this work, we utilize 3D FEM (finite element method) modelling to get an insight into the valve actuation process numerically. Specifically, the progressive debonding process at the elastomer interface is simulated with CZM (cohesive zone model) method. To minimize the actuation pressure, the V-shape design has been investigated and compared with a normal straight design. The geometrical effects of valve shape has been elaborated, in terms of valve actuation pressure. Based on our simulated results, we formulate the main concerns for micro valve design and fabrication, which is significant for minimizing actuation pressures and ensuring reliable operation.

  16. IEEE Std 382-1980: IEEE standard for qualification of safety-related valve actuators

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of all safety-related functions of power-driven valve actuators

  17. Actuation and system design and evaluation OMS engine shutoff valve, Volume 1. [space shuttles

    Science.gov (United States)

    Dunn, V. B.

    1975-01-01

    A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

  18. Inducement of Design Parameters for Reliability Improvement of Servo Actuator for Hydraulic Valve Operation

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Baek Ju; Kim, Do Sik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2014-05-15

    The precision hydraulic valve is widely used in various industrial field like aircraft, automobile, and general machinery. Servo actuator is the most important device for driving the precise hydraulic valve. The reliable operation of servo actuator effects on the overall hydraulic system. The performance of servo actuator relies on frequency response and step response according to arbitrary input signal. In this paper, we performed the analysis for the components of servo actuator to satisfy the reliable operation and response characteristics through the reliability analysis, and also induced the design parameters to realize the reliable operation and fast response characteristics of servo actuator for hydraulic valve operation through the empirical knowledge of experts and electromagnetic theories. We suggested the design equations to determine the values of design parameters of servo actuator as like bobbin size, length of yoke and plunger and turn number of coil, and verified the achieved design values through FEM analysis and performance tests using some prototypes of servo actuators adapted in hydraulic valve.

  19. Real-Time Prognostics of a Rotary Valve Actuator

    Science.gov (United States)

    Daigle, Matthew

    2015-01-01

    Valves are used in many domains and often have system-critical functions. As such, it is important to monitor the health of valves and their actuators and predict remaining useful life. In this work, we develop a model-based prognostics approach for a rotary valve actuator. Due to limited observability of the component with multiple failure modes, a lumped damage approach is proposed for estimation and prediction of damage progression. In order to support the goal of real-time prognostics, an approach to prediction is developed that does not require online simulation to compute remaining life, rather, a function mapping the damage state to remaining useful life is found offline so that predictions can be made quickly online with a single function evaluation. Simulation results demonstrate the overall methodology, validating the lumped damage approach and demonstrating real-time prognostics.

  20. The analysis of actuating mechanism and review of concepts for the vortex valve

    International Nuclear Information System (INIS)

    Park, Jong Kyun; Sim, Yun Seop; Joung, Sae Won; Lee, Ki Young; Lee, Jun; Kim, Young In

    1995-12-01

    To understand the basic features of the passive fluidic device, which is increasing available core cooling water from the safety injection tanks in the KNGR, review of the existing vortex valves concepts and analysis of the actuating mechanism of them have been performed and the results are as following: * Preliminary methodology development for parallel two water columns behavior, which is similar to the SIT valve actuation condition * Preliminary methodology for the vortex value actuation features * Analysis of the parallel water columns behavior and vortex valve actuation features using the results of above activities * Further works to be done in the analytical methodology. 16 figs., 2 refs. (Author) .new

  1. Integrated nozzle - flapper valve with piezoelectric actuator and isothermal chamber: a feedback linearization multi control device

    Energy Technology Data Exchange (ETDEWEB)

    Kamali, Mohammadreza; Jazayeri, Seyed Ali [K. N.Toosi University of Technology, Tehran (Iran, Islamic Republic of); Najafi, Farid [University of Guilan, Rasht (Iran, Islamic Republic of); Kawashima, Kenji [Tokyo Medical and Dental University, Tokyo (Japan); Kagawa, Toshiharu [Tokyo Institute of Technology, Tokyo (Japan)

    2016-05-15

    This paper introduces a new nozzle-flapper valve with isothermal chamber using piezoelectric actuator. It controls the pressure and flow rate simply, effectively and separately. The proposed valve uses isothermal chamber presenting practical isothermal condition due to its large heat transfer interfaces filled by metal wool. The valve uses stacked type piezoelectric actuator with unique advantages. By using this valve, a simple method has been fulfilled to control flow rate or pressure of ideal gases in a pneumatic actuators. Experimental results demonstrated applications of the proposed valve to control either pressure or flow rate in pneumatic circuits. This valve can be also used in the pilot stage valve to actuate the main stage of a much bigger pneumatic valve. Designated structure contains only one pressure sensor installed on the isothermal control chamber, capable of controlling both pressure and flow rate. The desired output mass flow rate of the valve is controlled by the pressure changes during positioning of piezoelectric actuator at proper position. The proposed valve can control steady and unsteady oscillatory flow rate and pressure effectively, using nonlinear control method such as feedback linearization approach. Its effectiveness is demonstrated and validated through simulation and experiments.

  2. The Actuator Fault Diagnosis Based on the Valve Friction

    Directory of Open Access Journals (Sweden)

    Jiajiang Li

    2014-08-01

    Full Text Available Control valve (actuator is the frequently moving terminal Instrument of the control system. To avoid the leaking of the actuator, there is packing at the moving parts. However, the friction caused by the packing can do harm to the control of the system. The washing effect of the media, high temperature, high pressure, frequent movement and other effects can result in the leaking of the packing and the deformation of the valve stem, which causes the change of the friction. The study of the control of the friction has always been an interesting topic in the industry. In this paper, we theoretically analyze the relationship of the friction of the packing and the static performance of the control valve, and offer a method to check the quality of the moving parts by attaching a strain gage (strain rosette to the empty part of the valve stem. This method has been demonstrated via experiment and a method to do error detection is provided at last.

  3. Normally-Closed Zero-Leak Valve with Magnetostrictive Actuator

    Science.gov (United States)

    Ramspacher, Daniel J. (Inventor); Richard, James A. (Inventor)

    2017-01-01

    A non-pyrotechnic, normally-closed, zero-leak valve is a replacement for the pyrovalve used for both in-space and launch vehicle applications. The valve utilizes a magnetostrictive alloy for actuation, rather than pyrotechnic charges. The alloy, such as Terfenol-D, experiences magnetostriction, i.e. a gross elongation, when exposed to a magnetic field. This elongation fractures a parent metal seal, allowing fluid flow through the valve. The required magnetic field is generated by redundant coils that are isolated from the working fluid.

  4. Worcester 1 Inch Solenoid-Actuated Gas-Operated VPS System Ball Valve

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    1 inch Gas-operated full-port ball valve incorporates a solenoid and limit switches as integral parts of the actuator. The valve is normally open and fails safe to the closed position. The associated valve position switch is class GS

  5. High Reliability Cryogenic Piezoelectric Valve Actuator, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Piezoelectric actuators constructed with the "smart material" PZT offer many potential advantages for use in NASA cryo-valve missions relative to conventional...

  6. Hydraulic engine valve actuation system including independent feedback control

    Science.gov (United States)

    Marriott, Craig D

    2013-06-04

    A hydraulic valve actuation assembly may include a housing, a piston, a supply control valve, a closing control valve, and an opening control valve. The housing may define a first fluid chamber, a second fluid chamber, and a third fluid chamber. The piston may be axially secured to an engine valve and located within the first, second and third fluid chambers. The supply control valve may control a hydraulic fluid supply to the piston. The closing control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the second fluid chamber to the supply control valve. The opening control valve may be located between the supply control valve and the second fluid chamber and may control fluid flow from the supply control valve to the second fluid chamber.

  7. Electric actuator for the sempell gate valve

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, E.C.

    1996-12-01

    The automation of valves has a primary importance in the scope of central control and regulation of power generation processes in power plants and especially in nuclear power plants. AUMA WERNER RIESTER GmbH & Co. KG is considered a leading manufacturer of electric actuators for the automation of valves. More than 30 years experience in designing, developing, and manufacturing provide a sound basis for offering reliable products, especially for nuclear applications. The quality assurance system of AUMA was developed according to 10 CFR 50, Appendix B and has been consistently accomplished. The program was certified by the TUV Germany (Technical Authorized Inspection Agency), according to ISO-9001, in 1994. AUMA offers two actuator type ranges for application in nuclear power plants. The range SAI is qualified according to IEEE 382-1978 and is designed for inside containment. The range SAN is qualified according to IEEE 382-1985 and KTA 3504-1988 for use in non-radioactive applications in the nuclear power plants.

  8. Modelling of Moving Coil Actuators in Fast Switching Valves Suitable for Digital Hydraulic Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Roemer, Daniel Beck; Bech, Michael Møller

    2015-01-01

    an estimation of the eddy currents generated in the actuator yoke upon current rise, as they may have significant influence on the coil current response. The analytical model facilitates fast simulation of the transient actuator response opposed to the transient electro-magnetic finite element model which......The efficiency of digital hydraulic machines is strongly dependent on the valve switching time. Recently, fast switching have been achieved by using a direct electromagnetic moving coil actuator as the force producing element in fast switching hydraulic valves suitable for digital hydraulic...... machines. Mathematical models of the valve switching, targeted for design optimisation of the moving coil actuator, are developed. A detailed analytical model is derived and presented and its accuracy is evaluated against transient electromagnetic finite element simulations. The model includes...

  9. A new surgical technique of intra-scleral tube fixation in Ahmed Glaucoma Valve implantation: ‘Scleral Sleeve Method’

    Directory of Open Access Journals (Sweden)

    Charudutt Kalamkar

    2017-10-01

    Full Text Available Purpose: To present a new surgical technique ‘Scleral Sleeve Method’ which would reduce the risk of Ahmed Glaucoma Valve (AGV tube related complications in patients undergoing AGV FP7 (New World Medical Inc., Rancho Cucamonga, CA for refractory glaucoma. Design: Prospective, Non-Randomized, hospital based interventional case series. Subjects: A total of 16 eyes of adult patients (10 males and 6 females with refractory glaucoma. Methods: Instead of using sutures to fix the AGV tube to sclera, we devised a novel method of intra-scleral tube fixation by creating a scleral tunnel fashioned in form of sleeve. Main outcome measure: Post-operative tube related complications. Result: There were no tube related complications such as exposure, extrusion or retraction in any of the cases. Conclusion: Use of scleral sleeve method for tube fixation, along with graft to cover the tube, will provide additional safety measure and reduce the risks of tube related complications. Keywords: Ahmed Glaucoma Valve, Scleral Sleeve Method, Intra-scleral tube fixation

  10. Topology Selection and Analysis of Actuator for Seat Valves suitable for use in Digital Displacement Pumps/Motors

    DEFF Research Database (Denmark)

    Rømer, Daniel; Johansen, Per; Pedersen, Henrik C.

    2013-01-01

    seat valves is developed, and the resulting dynamic response of the seat valve is presented. Requirements for the valve actuator is established based on the DD application, and three feasible actuator topologies are analyzed by means of transient electro-magnetic FEA simulation. From this analysis...

  11. System and method for controlling engine knock using electro-hydraulic valve actuation

    Science.gov (United States)

    Brennan, Daniel G

    2013-12-10

    A control system for an engine includes a knock control module and a valve control module. The knock control module adjusts a period that one or more of an intake valve and an exhaust valve of a cylinder are open based on engine knock corresponding to the cylinder. The valve control module, based on the adjusted period, controls the one or more of the intake valve and the exhaust valve using one or more hydraulic actuators.

  12. Space Shuttle Orbital Maneuvering Subsystem (OMS) Engine Propellant Leakage Ball-Valve Shaft Seals

    Science.gov (United States)

    Lueders, Kathy; Buntain, Nick; Fries, Joseph (Technical Monitor)

    1999-01-01

    Evidence of propellant leakage across ball-valve shaft seals has been noted during the disassembly of five flight engines and one test engine at the NASA Lyndon B. Johnson Space Center, White Sands Test Facility. Based on data collected during the disassembly of these five engines, the consequences of propellant leakage across the ball-valve shaft seals can be divided into four primary areas of concern: Damage to the ball-valve pinion shafts, damage to sleeved bearings inside the ball-valve and actuator assemblies, degradation of the synthetic rubber o-rings used in the actuator assemblies, and corrosion and degradation to the interior of the actuator assemblies. The exact time at which leakage across the ball-valve shaft seals occurs has not been determined, however, the leakage most likely occurs during engine firings when, depending on the specification used, ball-valve cavity pressures range as high as 453 to 550 psia. This potential pressure range for the ball-valve cavities greatly exceeds the acceptance leakage test pressure of 332 psia. Since redesign and replacement of the ball-valve shaft seals is unlikely, the near term solution to prevent damage that occurs from shaft-seal leakage is to implement a routine overhaul and maintenance program for engines in the fleet. Recommended repair, verification, and possible preventative maintenance measures are discussed in the paper.

  13. Worcester 1 Inch Solenoid-Actuated Gas Operated SCHe System Valves

    International Nuclear Information System (INIS)

    VAN KATWIJK, C.

    2000-01-01

    1 inch Gas-operated full-port ball valves incorporate a solenoid and limit switches as integral parts of the actuator. These valves are normally open and fail safe to the open position (GOV-1*02 and 1*06 fail closed) to provide a flow path of helium gas to the MCO under helium purge and off-normal conditions when the MCO is isolated

  14. A study on flow distribution for integrated hybrid actuator by analysis of reed valve

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Jang Mi; Kang, Seung Hwan; Ko, Han Seo [Sungkyunkwan University, Suwon (Korea, Republic of); Goo, Nam Seo; Li, Yong Zhe [Konkuk University, Seoul (Korea, Republic of)

    2016-05-15

    Many studies have been conducted recently on an integrated hybrid actuator due to the increasing need for unmanned aircraft and guided weapons. In this study, flow distribution was analyzed for a reed valve which was used for flow regulation to improve the performance of the actuator. By using a Fluid structural interaction (FSI) technique with Computational fluid dynamics (CFD) having a moving mesh, numerical analysis was performed according to the thickness, shape and driving frequency of the reed valve. From the calculated results, the maximum performance of the reed valve was found at the valve thickness of 0.15 mm and the driving frequency of 250 Hz for a no-load state. The optimum thickness and shape for the valve for each driving frequency were also realized.

  15. Optimum Design of a Moving Coil Actuator for Fast-Switching Valves in Digital Hydraulic Pumps and Motors

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Bech, Michael Møller; Johansen, Per

    2015-01-01

    Fast-switching seat valves suitable for digital hydraulic pumps and motors utilize direct electromagnetic actuators, which must exhibit superior transient performance to allow efficient operation of the fluid power pump/motor. A moving coil actuator resulting in a minimum valve switching time...... is designed for such valves using transient finite-element analysis of the electromagnetic circuit. The valve dynamics are coupled to the fluid restrictive forces, which significantly influence the effective actuator force. Fluid forces are modeled based on transient computational fluid dynamics models....... The electromagnetic finite-element model is verified against experimental measurement, and used to design an optimum moving coil actuator for the application considering different voltage-current ratios of the power supply. Results show that the optimum design depends on the supply voltage-current ratio, however...

  16. Baking Powder Actuated Centrifugo-Pneumatic Valving for Automation of Multi-Step Bioassays

    Directory of Open Access Journals (Sweden)

    David J. Kinahan

    2016-10-01

    Full Text Available We report a new flow control method for centrifugal microfluidic systems; CO2 is released from on-board stored baking powder upon contact with an ancillary liquid. The elevated pressure generated drives the sample into a dead-end pneumatic chamber sealed by a dissolvable film (DF. This liquid incursion wets and dissolves the DF, thus opening the valve. The activation pressure of the DF valve can be tuned by the geometry of the channel upstream of the DF membrane. Through pneumatic coupling with properly dimensioned disc architecture, we established serial cascading of valves, even at a constant spin rate. Similarly, we demonstrate sequential actuation of valves by dividing the disc into a number of distinct pneumatic chambers (separated by DF membranes. Opening these DFs, typically through arrival of a liquid to that location on a disc, permits pressurization of these chambers. This barrier-based scheme provides robust and strictly ordered valve actuation, which is demonstrated by the automation of a multi-step/multi-reagent DNA-based hybridization assay.

  17. Development of multilayer piezoelectric actuator valve for JT-60

    International Nuclear Information System (INIS)

    Miyo, Yasuhiko; Hiratsuka, Hajime; Masui, Hiroshi; Hosogane, Nobuyuki; Miya, Naoyuki

    2001-11-01

    In order to improve the gas injection valve used for the operation of JT-60, a new type of valve (multilayer piezoelectric actuator valve) was developed. The conventional valve (bimorph piezoelectric valve) has been used for 15 years since the beginning of experimental operation in April, 1985. However, it came to be hard to keep the performance of the valve because of the deterioration of the driving source, i.e. piezoelectric element. Developments of the new valve were carried out based on experiences through experimental operations in JT-60. Requirements for the design are: (1) to be hard structure for making a sheet leak, (2) to allow a repair work at atmosphere side without an air vent of the vacuum vessel, (3) to be more smaller and lighter compared with the conventional one, and (4) to have a high maintenance efficiency by utilizing of the commercial piezoelectric elements and power supplies. The newly developed valve was examined with various tests such as gas flow characteristic test, high magnetic field proof test, high temperature proof test and gas flow rate test for aged deterioration. Results, confirm that the performance of the valve is applicable for JT-60 operations. (author)

  18. Failure analysis of globe control valves with spring-diaphragm actuator for nuclear power plant applications

    International Nuclear Information System (INIS)

    Khan, M.R.; Chen, W.W.H.; Wang, T.Y.

    1997-01-01

    The results of the failure analysis of a globe control valve with spring-diaphragm actuator indicated that the diaphragm failed because the service loading is close to the strength of the diaphragm. The resulting impact force is significantly larger than the plug guide strength and that cause it to bulge out after the impact. To improve the valve performance, proper torque should be used to tighten the actuator diaphragm case fasteners. A stronger actuator diaphragm could be used to provide additional safety margin during operation. Stiffening the plug guide may avoid jamming the bushing

  19. Extended Sleeve Products Allow Control and Monitoring of Process Fluid Flows Inside Shielding, Behind Walls and Beneath Floors - 13041

    Energy Technology Data Exchange (ETDEWEB)

    Abbott, Mark W. [Flowserve Corporation, 1978 Foreman Drive Cookeville, TN 38506 (United States)

    2013-07-01

    Throughout power generation, delivery and waste remediation, the ability to control process streams in difficult or impossible locations becomes increasingly necessary as the complexity of processes increases. Example applications include radioactive environments, inside concrete installations, buried in dirt, or inside a shielded or insulated pipe. In these situations, it is necessary to implement innovative solutions to tackle such issues as valve maintenance, valve control from remote locations, equipment cleaning in hazardous environments, and flow stream analysis. The Extended Sleeve family of products provides a scalable solution to tackle some of the most challenging applications in hazardous environments which require flow stream control and monitoring. The Extended Sleeve family of products is defined in three groups: Extended Sleeve (ESV), Extended Bonnet (EBV) and Instrument Enclosure (IE). Each of the products provides a variation on the same requirements: to provide access to the internals of a valve, or to monitor the fluid passing through the pipeline through shielding around the process pipe. The shielding can be as simple as a grout filled pipe covering a process pipe or as complex as a concrete deck protecting a room in which the valves and pipes pass through at varying elevations. Extended Sleeves are available between roughly 30 inches and 18 feet of distance between the pipeline centerline and the top of the surface to which it mounts. The Extended Sleeve provides features such as ± 1.5 inches of adjustment between the pipeline and deck location, internal flush capabilities, automatic alignment of the internal components during assembly and integrated actuator mounting pads. The Extended Bonnet is a shorter fixed height version of the Extended Sleeve which has a removable deck flange to facilitate installation through walls, and is delivered fully assembled. The Instrument Enclosure utilizes many of the same components as an Extended Sleeve

  20. Effects of dynamic loading of motor-operated valve actuators

    International Nuclear Information System (INIS)

    Damerell, P.S.; Daubresse, S.; Wolfe, K.J.; Dogan, T.; Gleeson, J.

    1994-01-01

    Experience has shown that valves with rising, nonrotating stems that are operated using electro-motor driven actuators can be susceptible to changes in output thrust at a constant torque switch setting as a result of changes in stem load time history. This effect is a concern because tests on these types of valves to verify thrust achieved at torque switch trip are often performed in situ under load conditions different from the required performance conditions. As part of a motor-operated valve research program being carried out by the Electric Power Research Institute, tests of typical electric motor actuators used with nuclear services valves have been performed. The test results show that changes in output thrust with load time history occur o varying degrees on different stem and stem nut combinations. When the effect exists, there is generally an increase in thrust at torque switch trip when load is developed rapidly from low initial loads, compared to when load is developed slowly. The effect is mainly a result of changes in the coefficient of friction at the stem-stem nut interface. The coefficient of friction is temporarily reduced under rapid loading conditions from low initial load, leading to increased thrust. The root cause is hypothesized to be a open-quotes squeeze-filmclose quotes effect, whereby mixed-mode lubrication (hydrodynamic plus boundary) temporarily replaces boundary lubrication. This paper describes the results of tests performed to better understand the phenomenon

  1. A study on modelling of a butterfly-type control valve by a pneumatic actuator

    International Nuclear Information System (INIS)

    Hwang, I Cheol; Park, Cheol Jae

    2009-01-01

    This paper studies on the modelling of a butterfly-type control valve actuating by an on-off pneumatic solenoid valve. The mathematical model is composed of nonlinear differential equations three parts: (i) a solenoid valve, (ii) a pneumatic cylinder, (iii) a rotary-type butterfly valve. The flow characteristics of the butterfly control valve is analysed by a computer simulator, then its simple transfer function is identified from the step responses.

  2. Motor-operated valve (MOV) actuator motor and gearbox testing

    International Nuclear Information System (INIS)

    DeWall, K.; Watkins, J.C.; Bramwell, D.

    1997-07-01

    Researchers at the Idaho National Engineering and Environmental Laboratory tested the performance of electric motors and actuator gearboxes typical of the equipment installed on motor-operated valves used in nuclear power plants. Using a test stand that simulates valve closure loads against flow and pressure, the authors tested five electric motors (four ac and one dc) and three gearboxes at conditions a motor might experience in a power plant, including such off-normal conditions as operation at high temperature and reduced voltage. They also monitored the efficiency of the actuator gearbox. All five motors operated at or above their rated starting torque during tests at normal voltages and temperatures. For all five motors, actual torque losses due to voltage degradation were greater than the losses calculated by methods typically used for predicting motor torque at degraded voltage conditions. For the dc motor the actual torque losses due to elevated operating temperatures were greater than the losses calculated by the typical predictive method. The actual efficiencies of the actuator gearboxes were generally lower than the running efficiencies published by the manufacturer and were generally nearer the published pull-out efficiencies. Operation of the gearbox at elevated temperature did not affect the operating efficiency

  3. Design and Performance Evaluation of an Electro-Hydraulic Camless Engine Valve Actuator for Future Vehicle Applications.

    Science.gov (United States)

    Nam, Kanghyun; Cho, Kwanghyun; Park, Sang-Shin; Choi, Seibum B

    2017-12-18

    This paper details the new design and dynamic simulation of an electro-hydraulic camless engine valve actuator (EH-CEVA) and experimental verification with lift position sensors. In general, camless engine technologies have been known for improving fuel efficiency, enhancing power output, and reducing emissions of internal combustion engines. Electro-hydraulic valve actuators are used to eliminate the camshaft of an existing internal combustion engines and used to control the valve timing and valve duration independently. This paper presents novel electro-hydraulic actuator design, dynamic simulations, and analysis based on design specifications required to satisfy the operation performances. An EH-CEVA has initially been designed and modeled by means of a powerful hydraulic simulation software, AMESim, which is useful for the dynamic simulations and analysis of hydraulic systems. Fundamental functions and performances of the EH-CEVA have been validated through comparisons with experimental results obtained in a prototype test bench.

  4. SMA spring-based artificial muscle actuated by hot and cool water using faucet-like valve

    Science.gov (United States)

    Park, Cheol Hoon; Son, Young Su

    2017-04-01

    An artificial muscle for a human arm-like manipulator with high strain and high power density are under development, and an SMA(Shape memory alloy) spring is a good actuator for this application. In this study, an artificial muscle composed of a silicon tube and a bundle of SMA(Shape memory alloy) springs is evaluated. A bundle of SMA springs consists of five SMA springs which are fabricated by using SMA wires with a diameter of 0.5 mm, and hot and cool water actuates it by heating and cooling SMA springs. A faucet-like valve was also developed to mix hot water and cool water and control the water temperature. The mass of silicon tube and a bundle of SMA springs is only 3.3 g and 2.25 g, respectively, and the total mass of artificial muscle is 5.55 g. It showed good actuating performance for a load with a mass of 2.3 kg and the power density was more than 800 W/kg for continuous valve switching with a cycle of 0.6 s. The faucet-like valve can switch a water output from hot water to cold water within 0.3s, and the artificial muscle is actuated well in response to the valve position and speed. It is also presented that the temperature of the mixed water can be controlled depending on the valve position, and the displacement of the artificial muscle can be controlled well by the mixed water. Based on these results, SMA spring-based artificial muscle actuated by hot and cool water could be applicable to the human arm-like robot manipulators.

  5. Simulation of proportional control of hydraulic actuator using digital hydraulic valves

    Science.gov (United States)

    Raghuraman, D. R. S.; Senthil Kumar, S.; Kalaiarasan, G.

    2017-11-01

    Fluid power systems using oil hydraulics in earth moving and construction equipment have been using proportional and servo control valves for a long time to achieve precise and accurate position control backed by system performance. Such valves are having feedback control in them and exhibit good response, sensitivity and fine control of the actuators. Servo valves and proportional valves are possessing less hysteresis when compared to on-off type valves, but when the servo valve spools get stuck in one position, a high frequency called as jitter is employed to bring the spool back, whereas in on-off type valves it requires lesser technology to retract the spool. Hence on-off type valves are used in a technology known as digital valve technology, which caters to precise control on slow moving loads with fast switching times and with good flow and pressure control mimicking the performance of an equivalent “proportional valve” or “servo valve”.

  6. Soft Robotic Actuators

    Science.gov (United States)

    Godfrey, Juleon Taylor

    In this thesis a survey on soft robotic actuators is conducted. The actuators are classified into three main categories: Pneumatic Artificial Muscles (PAM), Electronic Electroactive Polymers (Electric EAP), and Ionic Electroactive Polymers (Ionic EAP). Soft robots can have many degrees and are more compliant than hard robots. This makes them suitable for applications that are difficult for hard robots. For each actuator background history, build materials, how they operate, and modeling are presented. Multiple actuators in each class are reviewed highlighting both their use and their mathematical formulation. In addition to the survey the McKibben actuator was chosen for fabrication and in-depth experimental analysis. Four McKibben actuators were fabricated using mesh sleeve, barbed hose fittings, and different elastic bladders. All were actuated using compressed air. Tensile tests were performed for each actuator to measure the tension force as air pressure increased from 20 to 100 psi in 10 psi increments. To account for material relaxation properties eleven trials for each actuator were run for 2-3 days. In conclusion, the smallest outer diameter elastic bladder was capable of producing the highest force due to the larger gap between the bladder and the sleeve.

  7. Sliding spool design for reducing the actuation forces in direct operated proportional directional valves: Experimental validation

    International Nuclear Information System (INIS)

    Amirante, Riccardo; Distaso, Elia; Tamburrano, Paolo

    2016-01-01

    Highlights: • An innovative procedure to design a commercial proportional directional valve is shown. • Experimental tests are performed to demonstrate the flow force reduction. • The design is improved by means of a previously made optimization procedure. • Great reduction in the flow forces without reducing the flow rate is demonstrated. - Abstract: This paper presents the experimental validation of a new methodology for the design of the spool surfaces of four way three position direct operated proportional directional valves. The proposed methodology is based on the re-design of both the compensation profile (the central conical surface of the spool) and the lateral surfaces of the spool, in order to reduce the flow forces acting on the spool and hence the actuation forces. The aim of this work is to extend the application range of these valves to higher values of pressure and flow rate, thus avoiding the employment of more expensive two stage configurations in the case of high-pressure conditions and/or flow rate. The paper first presents a theoretical approach and a general strategy for the sliding spool design to be applied to any four way three position direct operated proportional directional valve. Then, the proposed approach is experimentally validated on a commercially available valve using a hydraulic circuit capable of measuring the flow rate as well as the actuation force over the entire spool stroke. The experimental results, performed using both the electronic driver provided by the manufacturer and a manual actuation system, show that the novel spool surface requires remarkably lower actuation forces compared to the commercial configuration, while maintaining the same flow rate trend as a function of the spool position.

  8. Self-actuating and locking control for nuclear reactor

    International Nuclear Information System (INIS)

    Chung, D.K.

    1982-01-01

    A flow cutoff valve that is particularly suited for use with fluid-supported neutron absorber elements is described. The valve comprises a vertical elongated housing containing an apertured plate, an elongated nozzle member, and a flow cutoff sleeve. The nozzle has an opening in the bottom for receiving fluid and apertures near the top end for discharging fluid, as well as two sealing surfaces located above and below the apertures. The flow cutoff sleeve has walls surrounding the nozzle, a fluid flow opening at its upper end, and two sealing surfaces. The sleeve may move between an upper open position where the nozzle apertures are unobstructed, and a lower position in which the sleeve and nozzle sealing surfaces are mated and the flow of fluid through the nozzle apertures is blocked. Once the valve is in a closed position an increase in fluid pressure will keep it closed

  9. A Simple and Robust Sliding Mode Velocity Observer for Moving Coil Actuators in Digital Hydraulic Valves

    DEFF Research Database (Denmark)

    Nørgård, Christian; Schmidt, Lasse; Bech, Michael Møller

    2016-01-01

    This paper focuses on estimating the velocity and position of fast switching digital hydraulic valves actuated by electromagnetic moving coil actuators, based on measurements of the coil current and voltage. The velocity is estimated by a simple first-order sliding mode observer architecture...... and the position is estimated by integrating the estimated velocity. The binary operation of digi-valves enables limiting and resetting the position estimate since the moving member is switched between the mechanical end-stops of the valve. This enables accurate tracking since drifting effects due to measurement...... noise and integration of errors in the velocity estimate may be circumvented. The proposed observer architecture is presented along with stability proofs and initial experimental results. To reveal the optimal observer performance, an optimization of the observer parameters is carried out. Subsequently...

  10. IEEE Std 382-1985: IEEE standard for qualification of actuators for power operated valve assemblies with safety-related functions for nuclear power plants

    International Nuclear Information System (INIS)

    Anon.

    1992-01-01

    This standard describes the qualification of all types of power-driven valve actuators, including damper actuators, for safety-related functions in nuclear power generating stations. This standard may also be used to separately qualify actuator components. This standard establishes the minimum requirements for, and guidance regarding, the methods and procedures for qualification of power-driven valve actuators with safety-related functions Part I describes the qualification process. Part II describes the standard qualification cases and their environmental parameters for the usual locations of safety-related equipment in a nuclear generating station. Part III describes the qualification tests outlined in 6.3.3

  11. Remote actuated valve implant

    Science.gov (United States)

    McKnight, Timothy E; Johnson, Anthony; Moise, Jr., Kenneth J; Ericson, Milton Nance; Baba, Justin S; Wilgen, John B; Evans, III, Boyd McCutchen

    2014-02-25

    Valve implant systems positionable within a flow passage, the systems having an inlet, an outlet, and a remotely activatable valve between the inlet and outlet, with the valves being operable to provide intermittent occlusion of the flow path. A remote field is applied to provide thermal or magnetic activation of the valves.

  12. Valve system incorporating single failure protection logic

    Science.gov (United States)

    Ryan, Rodger; Timmerman, Walter J. H.

    1980-01-01

    A valve system incorporating single failure protective logic. The system consists of a valve combination or composite valve which allows actuation or de-actuation of a device such as a hydraulic cylinder or other mechanism, integral with or separate from the valve assembly, by means of three independent input signals combined in a function commonly known as two-out-of-three logic. Using the input signals as independent and redundant actuation/de-actuation signals, a single signal failure, or failure of the corresponding valve or valve set, will neither prevent the desired action, nor cause the undesired action of the mechanism.

  13. Hydraulic servo control spool valve

    Science.gov (United States)

    Miller, Donald M.

    1983-01-01

    A servo operated spool valve having a fixed sleeve and axially movable spool. The sleeve is machined in two halves to form a long, narrow tapered orifice slot across which a transverse wall of the spool is positioned. The axial position of the spool wall along the slot regulates the open orifice area with extreme precision.

  14. Carbon Fiber Reinforced Carbon Composites Rotary Valves for Internal Combustion Engines

    Science.gov (United States)

    Northam, G. Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    1999-01-01

    Carbon fiber reinforced carbon composite rotary, sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or warp-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties, do not present the sealing and lubrication problems that have prevented rotary, sleeve, and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  15. A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants

    International Nuclear Information System (INIS)

    Lee, Yong Bum; Lee, Jong Jik

    2016-01-01

    To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

  16. A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Lee, Jong Jik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2016-06-15

    To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

  17. Test of a Novel Moving Magnet Actuated Seat Valve for Digital Displacement Fluid Power Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Madsen, Esben Lundø; Christensen, Jeppe Haals

    2018-01-01

    The emerging digital displacement fluid power technology requires a new class of high-performance valves that can operate in harsh high-pressure conditions. To overcome the switching performance limitations of solenoids and to avoid the mechanical complexity of moving coil actuators, a novel elec......, and a simple mechanical design....

  18. Carbon Fiber Reinforced Carbon Composite Rotary Valve for an Internal Combustion Engine

    Science.gov (United States)

    Northam, G.Burton (Inventor); Ransone, Philip O. (Inventor); Rivers, H. Kevin (Inventor)

    2000-01-01

    Carbon fiber reinforced carbon composite rotary sleeve, and disc valves for internal combustion engines and the like are disclosed. The valves are formed from knitted or braided or wrap-locked carbon fiber shapes. Also disclosed are valves fabricated from woven carbon fibers and from molded carbon matrix material. The valves of the present invention with their very low coefficient of thermal expansion and excellent thermal and self-lubrication properties do not present the sealing and lubrication problems that have prevented rotary sleeve and disc valves from operating efficiently and reliably in the past. Also disclosed are a sealing tang to further improve sealing capabilities and anti-oxidation treatments.

  19. A rotary pneumatic actuator for the actuation of the exoskeleton knee joint

    Directory of Open Access Journals (Sweden)

    Jobin Varghese

    2017-07-01

    Full Text Available Rotary pneumatic actuators that are made out of linear one are always best suited for exoskeleton joint actuation due to its inherent power to weight ratio. This work is a modified version of knee actuation system that has already been developed and major modifications are made in order to make it more suitable for human wearing and also to reduce its bulkiness and complexity. The considered actuator system is a rotary actuator where a pulley converts the linear motion of the standard pneumatic piston into the rotary motion. To prove the capability of the actuator, its performance characteristics such as torque and power produced are compared to the required torque and power at the knee joint of the exoskeleton in swing phase and are found to be excellent. The two-way analysis of variance (ANOVA is performed to find the effect of the throat area valve on knee angle. The ANOVA shows the significant effect of the throat area variation on the knee angle flexion made by the proposed actuator. A relationship between the throat area of flow control valve, that is connected to the exit port of the direction control valve, and angular displacement of the knee joint has been formulated. This relationship can be used to design a control system to regulate the mass flow rate of air at the exit and hence the angular velocity of the knee joint can be controlled. Keywords: Driven pulley, Flow control valve, Rotary, Pneumatic cylinder

  20. Survey of industrial coal conversion equipment capabilities: valves

    Energy Technology Data Exchange (ETDEWEB)

    Bush, W. A.; Slade, E. C.

    1978-06-01

    A survey of the industrial capabilities of the valve and valve-actuator industry to supply large, high-pressure stop valves for the future coal conversion industry is presented in this report. Also discussed are development and testing capabilities of valve and valve-actuator manufacturers and anticipated lead times required to manufacture advanced design valves for the most stringent service applications. Results indicate that the valve and valve-actuator industry is capable of manufacturing in quantity equipment of the size and for the pressure and temperature ranges which would be required in the coal conversion industry. Valve manufacturers do not, however, have sufficient product application experience to predict the continuing functional ability of valves used for lock-hopper feeders, slurry feeders, and slag-char letdown service. Developmental and testing efforts to modify existing valve designs or to develop new valve concepts for these applications were estimated to range from 1 to 6 years. A testing facility to simulate actuation of critical valves under service conditions would be beneficial.

  1. Florida Sleeve Procedure Is Durable and Improves Aortic Valve Function in Marfan Syndrome Patients.

    Science.gov (United States)

    Aalaei-Andabili, Seyed Hossein; Martin, Tomas; Hess, Philip; Klodell, Charles; Karimi, Ashkan; Arnaoutakis, George; Lee, Teng; Beaver, Thomas

    2017-09-01

    The Florida sleeve (FS) procedure was developed as a simplified approach for repair of functional type I aortic insufficiency secondary to aortic root aneurysm. We evaluated postoperative aortic valve function, long-term survival, and freedom from reoperation in Marfan syndrome patients who underwent the FS procedure at our center. All Marfan syndrome patients undergoing FS procedure from May 2002 to December 2014 were included. Echocardiography assessment included left ventricular end-diastolic diameter (LVEDD), left ventricular end-systolic diameter (LVESD), ejection fraction, and degree of aortic insufficiency (none = 0, minimal = 1, mild = 2, moderate = 3, severe = 4). Social Security Death Index and primary care physicians' report were used for long-term follow-up. Thirty-seven Marfan syndrome patients, 21 (56.8%) men and 16 (43%) women with mean age of 35.08 ± 13.45 years underwent FL repair at our center. There was no in-hospital or 30-day death or stroke. Two patients required reoperation due to bleeding. Patients' survival rate was 94% at 1 to 8 years. Freedom from reoperation was 100% at 8 years. Twenty-five patients had postoperative follow-up echocardiography at 1 week. Aortic insufficiency grade significantly decreased after the procedure (preoperative mean ± SD: 1.76 ± 1.2 versus 1-week postoperative mean ± SD: 0.48 ± 0.71, p Marfan syndrome patients with immediate improvement in aortic valve function. Long-term survival and freedom from reoperation rates are encouraging. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  2. Hydraulically-actuated operating system for an electric circuit breaker

    Science.gov (United States)

    Barkan, Philip; Imam, Imdad

    1978-01-01

    This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A vent is located hydraulically between the actuating space and the valve for affording communication between said actuating space and a low pressure region. Flow control means is provided for restricting leakage through said vent to a rate that prevents said leakage from substantially detracting from the development of pressure within said actuatng space during the period from initial opening of the valve to the time when said piston has moved through most of its opening stroke. Following such period and while the valve is still open, said flow control means allows effective leakage through said vent. The accumulator has a limited capacity that results in the pressure within said actuating space decaying promptly to a low value as a result of effective leakage through said vent after the piston has moved through a circuit-breaker opening stroke and while the valve is in its open state. Means is provided for resetting the valve to its closed state in response to said pressure decay in the actuating space.

  3. Recent performance experience with US light water reactor self-actuating safety and relief valves

    Energy Technology Data Exchange (ETDEWEB)

    Hammer, C.G.

    1996-12-01

    Over the past several years, there have been a number of operating reactor events involving performance of primary and secondary safety and relief valves in U.S. Light Water Reactors. There are several different types of safety and relief valves installed for overpressure protection of various safety systems throughout a typical nuclear power plant. The following discussion is limited to those valves in the reactor coolant systems (RCS) and main steam systems of pressurized water reactors (PWR) and in the RCS of boiling water reactors (BWR), all of which are self-actuating having a setpoint controlled by a spring-loaded disk acting against system fluid pressure. The following discussion relates some of the significant recent experience involving operating reactor events or various testing data. Some of the more unusual and interesting operating events or test data involving some of these designs are included, in addition to some involving a number of similar events and those which have generic applicability.

  4. Optimization of Moving Coil Actuators for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck

    2016-01-01

    This paper focuses on deriving an optimal moving coil actuator design, used as force pro-ducing element in hydraulic on/off valves for Digital Displacement machines. Different moving coil actuator geometry topologies (permanent magnet placement and magnetiza-tion direction) are optimized for actu......This paper focuses on deriving an optimal moving coil actuator design, used as force pro-ducing element in hydraulic on/off valves for Digital Displacement machines. Different moving coil actuator geometry topologies (permanent magnet placement and magnetiza-tion direction) are optimized...... for actuating annular seat valves in a digital displacement machine. The optimization objectives are to the minimize the actuator power, the valve flow losses and the height of the actuator. Evaluation of the objective function involves static finite element simulation and simulation of an entire operation...... designs requires approximately 20 W on average and may be realized in 20 mm × Ø 22.5 mm (height × diameter) for a 20 kW pressure chamber. The optimization is carried out using the multi-objective Generalized Differential Evolu-tion optimization algorithm GDE3 which successfully handles constrained multi-objective...

  5. A magnetorheological actuation system: test and model

    International Nuclear Information System (INIS)

    John, Shaju; Chaudhuri, Anirban; Wereley, Norman M

    2008-01-01

    Self-contained actuation systems, based on frequency rectification of the high frequency motion of an active material, can produce high force and stroke output. Magnetorheological (MR) fluids are active fluids whose rheological properties can be altered by the application of a magnetic field. By using MR fluids as the energy transmission medium in such hybrid devices, a valving system with no moving parts can be implemented and used to control the motion of an output cylinder shaft. The MR fluid based valves are configured in the form of an H-bridge to produce bi-directional motion in an output cylinder by alternately applying magnetic fields in the two opposite arms of the bridge. The rheological properties of the MR fluid are modeled using both Bingham plastic and bi-viscous models. In this study, the primary actuation is performed using a compact terfenol-D rod driven pump and frequency rectification of the rod motion is done using passive reed valves. The pump and reed valve configuration along with MR fluidic valves form a compact hydraulic actuation system. Actuator design, analysis and experimental results are presented in this paper. A time domain model of the actuator is developed and validated using experimental data

  6. Results of the motor-operated valve engineering and testing program

    International Nuclear Information System (INIS)

    Black, B.R.

    1994-01-01

    The Texas Utilities Electric Company (TU Electric) motor-operated valve (MOV) program for implementing the recommendations of Generic Letter 89-10 has typically included the following: refurbishing each actuator, verifying each actuator's as-built configuration, testing each actuator's motor on a dynamometer, testing each actuator's torque spring pack (which is used to control the torque developed), testing each fully refurbished and reassembled actuator on a torque test stand, and testing as many MOVs as practicable both without fluid flow through the valve and with the maximum test conditions reasonably achievable (static and differential pressures (DP) conditions, respectively). Test data are acquired at 1,000 samples per second for stem thrust, stem torque, stem position, actuator compensator spring pack deflection, actuator torque spring pack deflection, motor current, motor voltage, motor three-phase power, valve upstream pressure, and valve downstream pressure, wherever practicable

  7. Preventive maintenance basis: Volume 16 -- Power operated relief valves, solenoid actuated. Final report

    International Nuclear Information System (INIS)

    Worledge, D.; Hinchcliffe, G.

    1997-07-01

    US nuclear plants are implementing preventive maintenance (PM) tasks with little documented basis beyond fundamental vendor information to support the tasks or their intervals. The Preventive Maintenance Basis project provides utilities with the technical basis for PM tasks and task intervals associated with 40 specific components such as valves, electric motors, pumps, and HVAC equipment. This report provides an overview of the PM Basis project and describes use of the PM Basis database. This volume 16 of the report provides a program of PM tasks suitable for application to power operated relief valves (PORV's) that are solenoid actuated. The PM tasks that are recommended provide a cost-effective way to intercept the causes and mechanisms that lead to degradation and failure. They can be used, in conjunction with material from other sources, to develop a complete PM program or to improve an existing program. Users of this information will be utility managers, supervisors, craft technicians, and training instructors responsible for developing, optimizing, or fine-tuning PM programs

  8. Cryogenic Cam Butterfly Valve

    Science.gov (United States)

    McCormack, Kenneth J. (Inventor)

    2016-01-01

    A cryogenic cam butterfly valve has a body that includes an axially extending fluid conduit formed there through. A disc lug is connected to a back side of a valve disc and has a circular bore that receives and is larger than a cam of a cam shaft. The valve disc is rotatable for a quarter turn within the body about a lug axis that is offset from the shaft axis. Actuating the cam shaft in the closing rotational direction first causes the camming side of the cam of the cam shaft to rotate the disc lug and the valve disc a quarter turn from the open position to the closed position. Further actuating causes the camming side of the cam shaft to translate the valve disc into sealed contact with the valve seat. Opening rotational direction of the cam shaft reverses these motions.

  9. Design And Analysis Of A Camless Valve Mechanism For I.C Engines Using Rotary Disc Valves

    Directory of Open Access Journals (Sweden)

    Vivek Jitendra Panchal

    2017-09-01

    Full Text Available It is the object of the presented paper to provide an electromechanical rotary valve actuating system for opening and closing valves of an internal combustion engine capable of separately controlling both the inlet and exhaust valve operations of each individual cylinder in a multi-cylinder engine. This indicates that only one valve will be required for each cylinder of the engine. Previously published versions of this concept require a separate valve for intake and exhaust in each cylinder. The system provides an alternative to the camshaft assembly in an attempt to overcome the limitations and inadequacies inevitably posed by a fully mechanical system. The prototype development is approached in a theoretical manner beginning with the conceptualization and design of a rotating disk with a notches and corresponding closure surfaces to open and close the flow path. The actuated disk and notch design is then refined and followed by the design of an inlet and exhaust manifold to correspond to the valve design and the theorizing and design of a sealing gasket. The rotating speed of the valve is determined by a general idling speed and can be varied to provide variable valve timing with the motor. The final assembly eliminates a majority of the moving parts currently used in camshaft systems like the cam camshaft rocker arm push rod and springs and results in a significantly lighter valve actuation system. By eliminating the translatory motion of valves the problem of valves slamming on the valve seats at high velocities is eliminated thus greatly reducing engine wear.

  10. High-Compression-Ratio; Atkinson-Cycle Engine Using Low-Pressure Direct Injection and Pneumatic-Electronic Valve Actuation Enabled by Ionization Current and Foward-Backward Mass Air Flow Sensor Feedback

    Energy Technology Data Exchange (ETDEWEB)

    Harold Schock; Farhad Jaberi; Ahmed Naguib; Guoming Zhu; David Hung

    2007-12-31

    This report describes the work completed over a two and one half year effort sponsored by the US Department of Energy. The goal was to demonstrate the technology needed to produce a highly efficient engine enabled by several technologies which were to be developed in the course of the work. The technologies included: (1) A low-pressure direct injection system; (2) A mass air flow sensor which would measure the net airflow into the engine on a per cycle basis; (3) A feedback control system enabled by measuring ionization current signals from the spark plug gap; and (4) An infinitely variable cam actuation system based on a pneumatic-hydraulic valve actuation These developments were supplemented by the use of advanced large eddy simulations as well as evaluations of fuel air mixing using the KIVA and WAVE models. The simulations were accompanied by experimental verification when possible. In this effort a solid base has been established for continued development of the advanced engine concepts originally proposed. Due to problems with the valve actuation system a complete demonstration of the engine concept originally proposed was not possible. Some of the highlights that were accomplished during this effort are: (1) A forward-backward mass air flow sensor has been developed and a patent application for the device has been submitted. We are optimistic that this technology will have a particular application in variable valve timing direct injection systems for IC engines. (2) The biggest effort on this project has involved the development of the pneumatic-hydraulic valve actuation system. This system was originally purchased from Cargine, a Swedish supplier and is in the development stage. To date we have not been able to use the actuators to control the exhaust valves, although the actuators have been successfully employed to control the intake valves. The reason for this is the additional complication associated with variable back pressure on the exhaust valves when

  11. A microfluidic control system with re-usable micropump/valve actuator and injection moulded disposable polymer lab-on-a-slide

    DEFF Research Database (Denmark)

    Bu, Minqiang; Perch-Nielsen, Ivan R.; Yi, Sun

    2011-01-01

    A microfluidic control system consisting of micropump/valves with a re-usable pneumatic actuator and a disposable polymer lab-on-a-slide is presented. The lab-on-a-slide was fabricated using low cost methods, such as injection moulding of TOPAS® cyclic olefin copolymer (COC) slide, lamination...... of different layers of polymer, and ultrasonic welding of TOPAS® lid to the slide. The re-usable pneumatic actuator not only simplifies the design of the lab-on-a-slide and reduces the fabrication cost, but also reduces the possibility of cross contamination during replacement of the disposable lab...

  12. Overflow control valve

    International Nuclear Information System (INIS)

    Kessinger, B.A.; Hundal, R.; Parlak, E.A.

    1982-01-01

    An overflow control valve for use in a liquid sodium coolant pump tank which can be remotely engaged with and disengaged from the pump tank wall to thereby permit valve removal. An actuating shaft for controlling the valve also has means for operating a sliding cylinder against a spring to retract the cylinder from sealing contact with the pump tank nozzle. (author)

  13. Valve monitoring ITI-MOVATS

    International Nuclear Information System (INIS)

    Moureau, S.

    1993-01-01

    ITI-MOVATS provides a wide range of test devices to monitor the performance of valves: motor operated gate or globe valve, butterfly valve, air operated valve, and check valve. The ITI-MOVATS testing equipment is used in the following three areas: actuator setup/baseline testing, periodic/post-maintenance testing, and differential pressure testing. The parameters typically measured with the MOVATS diagnostic system as well as the devices used to measure them are described. (Z.S.)

  14. 241-AN-A valve pit manifold valves and position indication acceptance test procedure

    Energy Technology Data Exchange (ETDEWEB)

    VANDYKE, D.W.

    1999-08-25

    This document describes the method used to test design criteria for gear actuated ball valves installed in 241-AN-A Valve Pit located at 200E Tank Farms. The purpose of this procedure is to demonstrate the following: Equipment is properly installed, labeled, and documented on As-Built drawings; New Manifold Valves in the 241-AN-A Valve Pit are fully operable using the handwheel of the valve operators; New valve position indicators on the valve operators will show correct valve positions; New valve position switches will function properly; and New valve locking devices function properly.

  15. Pneumatic Variable Series Elastic Actuator.

    Science.gov (United States)

    Zheng, Hao; Wu, Molei; Shen, Xiangrong

    2016-08-01

    Inspired by human motor control theory, stiffness control is highly effective in manipulation and human-interactive tasks. The implementation of stiffness control in robotic systems, however, has largely been limited to closed-loop control, and suffers from multiple issues such as limited frequency range, potential instability, and lack of contribution to energy efficiency. Variable-stiffness actuator represents a better solution, but the current designs are complex, heavy, and bulky. The approach in this paper seeks to address these issues by using pneumatic actuator as a variable series elastic actuator (VSEA), leveraging the compressibility of the working fluid. In this work, a pneumatic actuator is modeled as an elastic element with controllable stiffness and equilibrium point, both of which are functions of air masses in the two chambers. As such, for the implementation of stiffness control in a robotic system, the desired stiffness/equilibrium point can be converted to the desired chamber air masses, and a predictive pressure control approach is developed to control the timing of valve switching to obtain the desired air mass while minimizing control action. Experimental results showed that the new approach in this paper requires less expensive hardware (on-off valve instead of proportional valve), causes less control action in implementation, and provides good control performance by leveraging the inherent dynamics of the actuator.

  16. MEMS fluidic actuator

    Science.gov (United States)

    Kholwadwala, Deepesh K [Albuquerque, NM; Johnston, Gabriel A [Trophy Club, TX; Rohrer, Brandon R [Albuquerque, NM; Galambos, Paul C [Albuquerque, NM; Okandan, Murat [Albuquerque, NM

    2007-07-24

    The present invention comprises a novel, lightweight, massively parallel device comprising microelectromechanical (MEMS) fluidic actuators, to reconfigure the profile, of a surface. Each microfluidic actuator comprises an independent bladder that can act as both a sensor and an actuator. A MEMS sensor, and a MEMS valve within each microfluidic actuator, operate cooperatively to monitor the fluid within each bladder, and regulate the flow of the fluid entering and exiting each bladder. When adjacently spaced in a array, microfluidic actuators can create arbitrary surface profiles in response to a change in the operating environment of the surface. In an embodiment of the invention, the profile of an airfoil is controlled by independent extension and contraction of a plurality of actuators, that operate to displace a compliant cover.

  17. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    International Nuclear Information System (INIS)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung

    2016-01-01

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator

  18. Evaluation of Effective Diaphragm Area for Pneumatic Actuator

    Energy Technology Data Exchange (ETDEWEB)

    Ryu, Hogeun; Han, Bongsub; Seon, Juhyoung [SOOSAN INDUSTRIES, Seoul (Korea, Republic of)

    2016-10-15

    The purpose of this study is to develop a methodology to calculate the exact effective diaphragm area using the results of diagnostic test to be performed in the evaluation of air operated valve performance. By using this developed methodology in pneumatic actuator performance evaluation, it can be reduce the possible errors arising from effective diaphragm area in the evaluation of performance of air operated valves. The performance assessment for the operability and structural integrity of air operated valves for the domestic nuclear power plant is in progress. One of the important parameters that determine the performance of the air operated valves is the effective diaphragm area of diaphragm type actuator. The effective diaphragm area is the actual area which the air pressure acting on the diaphragm. In general, the effective diaphragm area used for the performance evaluation of pneumatic actuator is provided by the manufacture or the actuator drawing. Flat type diaphragm was showed the difference between the measured value of EDA and the manufacture’s value, in the case of convoluted type diaphragm has showed that the measured value of EDA and manufacture’s value is almost the same. When evaluate a performance of a diaphragm actuator, accurate EDA is to be used because it is an important variable affecting the actuator performance. Particularly in the case of flat type diaphragm which EDA is changed in accordance with the stroke position, by using the EDA evaluation methodology developed in this study to minimize a possible error due to EDA when evaluating the performance of the air actuator.

  19. Torsional fatigue model for limitorque type SMB/SB/SBD actuators for motor-operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Somogyi, D.; Alvarez, P.D.; Kalsi, M.S. [Kalsi Engineering, Inc., Sugar Land, TX (United States)

    1996-12-01

    Kalsi Engineering, Inc. has recently developed a computer program to predict the torsional fatigue life of Limitorque Type SMB/SB/SBD actuators for motor-operated valves under given loading levels, including those that exceed the ratings. The development effort was an outgrowth of the {open_quote}Thrust Rating Increase{close_quote} test program. The fatigue model computes all pertinent stress components and their variations as a function of the loading ramp. The cumulative damage and fatigue life due to stress cycling is computed by use of a modification of Miner`s rule. Model predictions were validated against actual cyclic loading test results.

  20. Torsional fatigue model for limitorque type SMB/SB/SBD actuators for motor-operated valves

    International Nuclear Information System (INIS)

    Somogyi, D.; Alvarez, P.D.; Kalsi, M.S.

    1996-01-01

    Kalsi Engineering, Inc. has recently developed a computer program to predict the torsional fatigue life of Limitorque Type SMB/SB/SBD actuators for motor-operated valves under given loading levels, including those that exceed the ratings. The development effort was an outgrowth of the open-quote Thrust Rating Increase close-quote test program. The fatigue model computes all pertinent stress components and their variations as a function of the loading ramp. The cumulative damage and fatigue life due to stress cycling is computed by use of a modification of Miner's rule. Model predictions were validated against actual cyclic loading test results

  1. Gastric Sleeve Surgery

    Science.gov (United States)

    ... Videos for Educators Search English Español Gastric Sleeve Surgery KidsHealth / For Teens / Gastric Sleeve Surgery What's in ... or buying healthy food ) Preparing for Gastric Sleeve Surgery Preparing for this major operation takes months of ...

  2. Numerical study on cavitation inception in the rotary valve of the hydraulic power steering system

    International Nuclear Information System (INIS)

    Ryu, Gwang Nyeon; Cho, Myung Hwan; Yoo, Jung Yul; Park, Sun Hong

    2009-01-01

    The rotary valve directs the power steering oil to either side of a power piston and relieves the driver of the effort to turn the wheel, when a driver begins to operate the vehicle. It is well known that the hiss noise occurring at that moment is caused mainly by cavitation of the oil inside the rotary valve. In this paper, two types of rotary valve (round and straight type) have been analyzed numerically using three-dimensional cavitation model embedded in the commercial code, FLUENT v6.2 and the results have been compared with the measured hiss noise level in a semi-anechoic chamber. The volume of the oil vapor generated from cavitation was larger in Round type valve which has a convex shape of the sleeve grooves than in Straight type valve which has a rectangular shape of the sleeve grooves. The hiss noise level of Round type valve was higher than that of Straight type valve as well. These results mean that the hiss noise can be reduced by the change of the shape of the grooves.

  3. High speed hydraulically-actuated operating system for an electric circuit breaker

    Science.gov (United States)

    Iman, Imdad

    1983-06-07

    This hydraulically-actuated operating system comprises a cylinder, a piston movable therein in an opening direction to open a circuit breaker, and an accumulator for supplying pressurized liquid to a breaker-opening piston-actuating space within the cylinder. A normally-closed valve between the accumulator and the actuating space is openable to allow pressurized liquid from the accumulator to flow through the valve into the actuating space to drive the piston in an opening direction. A dashpotting mechanism operating separately from the hydraulic actuating system is provided, thereby reducing flow restriction interference with breaker opening.

  4. A nuclear radiation actuated valve for a nuclear reactor

    International Nuclear Information System (INIS)

    Christiansen, D.W.; Schively, D.P.

    1983-01-01

    The valve has a first part (such as a valve rod with piston) and a second part (such as a valve tube surrounding the valve rod, with the valve tube having side slots surrounding the piston). Both valve parts have known nuclear radiation swelling characteristics which are different. The valve parts are positioned so that the valve's first and second parts create a valve orifice which changes in size due to the different nuclear radiation caused swelling of the valve's first part compared to the valve's second part. The valve may be used in a nuclear reactor's core coolant system. (author)

  5. Heat flux limiting sleeves

    Science.gov (United States)

    Harris, William G.

    1985-01-01

    A heat limiting tubular sleeve extending over only a portion of a tube having a generally uniform outside diameter, the sleeve being open on both ends, having one end thereof larger in diameter than the other end thereof and having a wall thickness which decreases in the same direction as the diameter of the sleeve decreases so that the heat transfer through the sleeve and tube is less adjacent the large diameter end of the sleeve than adjacent the other end thereof.

  6. A self-regulating valve for single-phase liquid cooling of microelectronics

    International Nuclear Information System (INIS)

    Donose, Radu; De Volder, Michaël; Peirs, Jan; Reynaerts, Dominiek

    2011-01-01

    This paper reports on the design, optimization and testing of a self-regulating valve for single-phase liquid cooling of microelectronics. Its purpose is to maintain the integrated circuit (IC) at constant temperature and to reduce power consumption by diminishing flow generated by the pump as a function of the cooling requirements. It uses a thermopneumatic actuation principle that combines the advantages of zero power consumption and small size in combination with a high flow rate and low manufacturing costs. The valve actuation is provided by the thermal expansion of a liquid (actuation fluid) which, at the same time, actuates the valve and provides feed-back sensing. A maximum flow rate of 38 kg h −1 passes through the valve for a heat load up to 500 W. The valve is able to reduce the pumping power by up to 60% and it has the capability to maintain the IC at a more uniform temperature.

  7. Characteristic analysis of servo valve

    International Nuclear Information System (INIS)

    Ko, J. H.; Ryu, D. R.; Lee, J. H.; Kim, Y. S.; Na, J. C.; Kim, D. S.

    2008-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  8. Aortic root reimplantation procedure: a new milestone in aortic valve-sparing operations

    Directory of Open Access Journals (Sweden)

    А. М. Чернявский

    2016-08-01

    Full Text Available Aim: Emphasis in this study was placed on clinical and functional assessment of a modified "Florida Sleeve" procedure during surgical correction of ascending aorta aneurysms with concomitant aortic insufficiency.Methods: 32 patients with an aneurysm of the ascending aorta and aortic insufficiency underwent a modified "Florida Sleeve" procedure. The average follow-up was 17 (0-60 months. The average age of patients was 57±13 (23-73 years 56±13 years.Results: The expected 4-year cumulative survival rate was 84.3%. Overall freedom from aortic insufficiency in the late period was 88.9%. Median aortic regurgitation was 1+ (1; 2. Long-term follow-up revealed no valve-associated complications.Conclusion: The aortic root reimplantation procedure enables optimal correction of the existing lesions of the aortic root without performing aortic valve replacement and demonstrates stable clinical and functional outcomes in the long-term period.Key words: aortic aneurysm; aortic valve; valve-sparing operations.FundingThe study had no sponsorship.Conflict of interestThe authors declare no conflict of interest.

  9. Guide tube sleeve

    International Nuclear Information System (INIS)

    Attix, D.J.

    1983-01-01

    The invention increases the operating capacity of a nuclear reactor by causing a modification in the flow pattern of the coolant which enhances the coolant's effectiveness. The apparatus provides a thin-walled tubular sleeve closely surrounding but not attached to the exterior surface of a guide tube in a fuel assembly. The wall of the sleeve has tabs projecting outwardly into adjacent flow channels. The sleeve is attached to the wall of a cellular void through which passes the guide tube associated with said sleeve. The tabs increase the flow of water in the channel and thus increase the heat transfer

  10. Piezoelectric valve for massive gas injection in ASDEX upgrade

    Energy Technology Data Exchange (ETDEWEB)

    Dibon, Mathias; Neu, Rudolf [Max-Planck-Institute for Plasmaphysics, Boltzmannstr. 2, 85748 Garching (Germany); Technical University Munich, Boltzmannstr. 15, 85748 Garching (Germany); Herrmann, Albrecht; Mank, Klaus; Mertens, Vitus; Pautasso, Gabriella; Ploeckl, Bernhard [Max-Planck-Institute for Plasmaphysics, Boltzmannstr. 2, 85748 Garching (Germany)

    2016-07-01

    A sudden loss of plasma temperature can cause a disruption, which poses a significant problem for current Tokamaks and future fusion devices. Hence, mitigating forces and thermal loads during disruptions is important for the integrity of the vessel and first wall components. Therefore, high speed gas valves are used to deliver a pulse of noble gas onto the plasma, which irradiates the thermal energy quickly, avoiding localized heat loads and mechanical stress due to induced currents. A new design for such a valve is currently under development. The valve plate is driven by two piezoelectric stack actuators. The stroke of the actuators (0.07 mm) is amplified by a monolithic titanium frame and reaches 2 mm. The frame also serves as spring to pre-load the actuators. In the idle state, it also presses the conical valve plate into the seal, closing the gas chamber (42 cm{sup 3}). The actuators accelerate the stem and the valve plate until it is fully opened after 2 ms. The orifice of the valve has a diameter of 14 mm. This allows a peak mass flow rate of the gas up to 8 . 10{sup 4} (Pa.m)/(s) after 1.8 ms and an average mass flow rate of 2 . 10{sup 4} (Pa.m)/(s) over the evacuation time of 10 ms. Therefore, one valve would be sufficient to deliver the required amount of gas to mitigate disruptions at ASDEX Upgrade.

  11. Turbo-generator control with variable valve actuation

    Science.gov (United States)

    Vuk, Carl T [Denver, IA

    2011-02-22

    An internal combustion engine incorporating a turbo-generator and one or more variably activated exhaust valves. The exhaust valves are adapted to variably release exhaust gases from a combustion cylinder during a combustion cycle to an exhaust system. The turbo-generator is adapted to receive exhaust gases from the exhaust system and rotationally harness energy therefrom to produce electrical power. A controller is adapted to command the exhaust valve to variably open in response to a desired output for the turbo-generator.

  12. Enhancing roll stability of heavy vehicle by LQR active anti-roll bar control using electronic servo-valve hydraulic actuators

    Science.gov (United States)

    Vu, Van Tan; Sename, Olivier; Dugard, Luc; Gaspar, Peter

    2017-09-01

    Rollover of heavy vehicle is an important road safety problem world-wide. Although rollovers are relatively rare events, they are usually deadly accidents when they occur. The roll stability loss is the main cause of rollover accidents in which heavy vehicles are involved. In order to improve the roll stability, most of modern heavy vehicles are equipped with passive anti-roll bars to reduce roll motion during cornering or riding on uneven roads. However these may be not sufficient to overcome critical situations. This paper introduces the active anti-roll bars made of four electronic servo-valve hydraulic actuators, which are modelled and integrated in a yaw-roll model of a single unit heavy vehicle. The control signal is the current entering the electronic servo-valve and the output is the force generated by the hydraulic actuator. The active control design is achieved solving a linear optimal control problem based on the linear quadratic regulator (LQR) approach. A comparison of several LQR controllers is provided to allow for tackling the considered multi-objective problems. Simulation results in frequency and time domains show that the use of two active anti-roll bars (front and rear axles) drastically improves the roll stability of the single unit heavy vehicle compared with the passive anti-roll bar.

  13. Sensor-integrated polymer actuators for closed-loop drug delivery system

    Science.gov (United States)

    Xu, Han; Wang, Chunlei; Kulinsky, Lawrence; Zoval, Jim; Madou, Marc

    2006-03-01

    This work presents manufacturing and testing of a closed-loop drug delivery system where drug release is achieved by an electrochemical actuation of an array of polymeric valves on a set of drug reservoirs. The valves are based on bi-layer structures made of polypyrrole/gold in the shape of a flap that is hinged on one side of a valve seat. Drugs stored in the underlying chambers are released by bending the bi-layer flaps back with a small applied bias. These polymeric valves simultaneously function as both drug release components and biological/chemical sensors responding to a specific biological or environmental stimulus. The sensors may send signals to the control module to realize closed-loop control of the drug release. In this study a glucose sensor has been integrated with the polymeric actuators through immobilization of glucose oxidase(GOx) within polypyrrole(PPy) valves. Sensitivities per unit area of the integrated glucose sensor have been measured and compared before and after the actuation of the sensor/actuator PPy/DBS/GOx film. Other sensing parameters such as linear range and response time were discussed as well. Using an array of these sensor/actuator cells, the amount of released drug, e.g. insulin, can be precisely controlled according to the surrounding glucose concentration detected by the glucose sensor. Activation of these reservoirs can be triggered either by the signal from the sensor, or by the signal from the operator. This approach also serves as the initial step to use the proposed system as an implantable drug delivery platform in the future.

  14. Sleeving repair of heat exchanger tubes

    International Nuclear Information System (INIS)

    Street, Michael D.; Schafer, Bruce W.

    2000-01-01

    Defective heat exchanger tubes can be repaired using techniques that do not involve the cost and schedule penalties of component replacement. FTI's years of experience repairing steam generator tubes have been successfully applied to heat exchangers. Framatome Technologies heat exchanger sleeves can bridge defective areas of the heat exchanger tubes, sleeves have been designed to repair typical heat exchanger tube defects caused by excessive tube vibration, stress corrosion cracking, pitting or erosion. By installing a sleeve, the majority of the tube's heat transfer and flow capacity is maintained and the need to replace the heat exchanger can be delayed or eliminated. Both performance and reliability are improved. FTI typically installs heat exchanger tube sleeves using either a roll expansion or hydraulic expansion process. While roll expansion of a sleeve can be accomplished very quickly, hydraulic expansion allows sleeves to be installed deep within a tube where a roll expander cannot reach. Benefits of FTI's heat exchanger tube sleeving techniques include: - Sleeves can be positioned any where along the tube length, and for precise positioning of the sleeve eddy current techniques can be employed. - Varying sleeve lengths can be used. - Both the roll and hydraulic expansion processes are rapid and both produce joints that do not require stress relief. - Because of low leak rates and speed of installations, sleeves can be used to preventatively repair likely-to-fail tubes. - Sleeves can be used for tube stiffening and to limit leakage through tube defects. - Because of installation speed, there is minimal impact on outage schedules and budgets. FTI's recently installed heat exchanger sleeving at the Kori-3 Nuclear Power Station in conjunction with Korea Plant Service and Engineering Co., Ltd. The sleeves were installed in the 3A and 3B component cooling water heat exchangers. A total of 859 tubesheet and 68 freespan sleeves were installed in the 3A heat

  15. The SNS Resonance Control Cooling System Control Valve Upgrade Performance

    International Nuclear Information System (INIS)

    Williams, Derrick C.; Schubert, James Phillip; Tang, Johnny Y.

    2008-01-01

    The normal-conducting linac of the Spallation Neutron Source (SNS) uses 10 separate Resonance Control Cooling System (RCCS) water skids to control the resonance of 6 Drift Tube Linac (DTL) and 4 Coupled Cavity Linac (CCL) accelerating structures. The RCCS water skids use 2 control valves; one to regulate the chilled water flow and the other to bypass water to a chilled water heat exchanger. These valves have hydraulic actuators that provide position and feedback to the control system. Frequency oscillations occur using these hydraulic actuators due to their coarse movement and control of the valves. New pneumatic actuator and control positioners have been installed on the DTL3 RCCS water skid to give finer control and regulation of DTL3 cavity temperature. This paper shows a comparison of resonance control performance for the two valve configurations.

  16. Electrical servo actuator bracket. [fuel control valves on jet engines

    Science.gov (United States)

    Sawyer, R. V. (Inventor)

    1981-01-01

    An electrical servo actuator is mounted on a support arm which is allowed to pivot on a bolt through a fixed mounting bracket. The actuator is pivotally connected to the end of the support arm by a bolt which has an extension allowed to pass through a slot in the fixed mounting bracket. An actuator rod extends from the servo actuator to a crank arm which turns a control shaft. A short linear thrust of the rod pivots the crank arm through about 90 for full-on control with the rod contracted into the servo actuator, and full-off control when the rod is extended from the actuator. A spring moves the servo actuator and actuator rod toward the control crank arm once the actuator rod is fully extended in the full-off position. This assures the turning of the control shaft to a full-off position. A stop bolt and slot are provided to limit pivot motion. Once fully extended, the spring pivots the motion.

  17. Design and performance characteristic analysis of servo valve-type water hydraulic poppet valve

    International Nuclear Information System (INIS)

    Park, Sung Hwan

    2009-01-01

    For water hydraulic system control, the flow or pressure control using high-speed solenoid valve controlled by PWM control method could be a good solution for prevention of internal leakage. However, since the PWM control of on-off valves cause extensive flow and pressure fluctuation, it is difficult to control the water hydraulic actuators precisely. In this study, the servo valve-type water hydraulic valve using proportional poppet as the main valve is designed and the performance characteristics of the servo valve-type water hydraulic valve are analyzed. Furthermore, it is demonstrated through experiments that a decline in control chamber pressure that follows the change of pilot flow is caused by the occurrence of cavitation around the proportional poppet, and that fundamental characteristics of the developed valve remain unaffected by the occurrence of cavitation

  18. Enhancement of pressurizer safety valve operability by seating design improvement

    International Nuclear Information System (INIS)

    Moisidis, N.T.; Ratiu, M.D.

    1995-01-01

    Operating conditions specific to pressurizer safety valves (PSVs) have led to numerous problems and have caused industry and NRC concerns regarding the adequacy of spring-loaded self-actuated safety valves for reactor coolant system (RCS) overpressure protection. Specific concerns are: setpoint drift, spurious actuations, and pressure protection. Specific concerns are: setpoint drift, spurious actuations, and leakage. Based on testing and valve construction analysis of a Crosby model 6M6 PSV (Moisidis and Ratiu, 1992), it was established that the primary contributor to the valve problems is a susceptibility to weak seating. To eliminate spring instability, a new spring washer was designed, which guides the spring and precludes its rotation from the reference installed position. Results of tests performed on a prototype PSV equipped with the modified upper spring washer has shown significant improvements in valve operability and a consistent setpoint reproducibility to less than ±1% of the PSV setpoint (testing of baseline, unmodified valve, resulted in a setpoint drift of ± 2%). Enhanced valve operability will result in a significant decrease in operating and maintenance costs associated with valve maintenance and testing. In addition, the enhanced setpoint reproducibility will allow the development of a nitrogen to steam correlation for future in-house PSV testing which will result in further reductions in costs associated with valve testing

  19. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve.

    Science.gov (United States)

    Gutfrind, Christophe; Dufour, Laurent; Liebart, Vincent; Vannier, Jean-Claude; Vidal, Pierre

    2016-05-20

    The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP) Exhaust Gas Recirculation (EGR) valve for use in Internal Combustion Engines (ICEs). The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM) using the FLUX-3D(®) software (CEDRAT, Meylan, France) will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink(®) in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system.

  20. An Approach to the Prototyping of an Optimized Limited Stroke Actuator to Drive a Low Pressure Exhaust Gas Recirculation Valve

    Science.gov (United States)

    Gutfrind, Christophe; Dufour, Laurent; Liebart, Vincent; Vannier, Jean-Claude; Vidal, Pierre

    2016-01-01

    The purpose of this article is to describe the design of a limited stroke actuator and the corresponding prototype to drive a Low Pressure (LP) Exhaust Gas Recirculation (EGR) valve for use in Internal Combustion Engines (ICEs). The direct drive actuator topology is an axial flux machine with two air gaps in order to minimize the rotor inertia and a bipolar surface-mounted permanent magnet in order to respect an 80° angular stroke. Firstly, the actuator will be described and optimized under constraints of a 150 ms time response, a 0.363 N·m minimal torque on an angular range from 0° to 80° and prototyping constraints. Secondly, the finite element method (FEM) using the FLUX-3D® software (CEDRAT, Meylan, France) will be used to check the actuator performances with consideration of the nonlinear effect of the iron material. Thirdly, a prototype will be made and characterized to compare its measurement results with the analytical model and the FEM model results. With these electromechanical behavior measurements, a numerical model is created with Simulink® in order to simulate an EGR system with this direct drive actuator under all operating conditions. Last but not least, the energy consumption of this machine will be estimated to evaluate the efficiency of the proposed EGR electromechanical system. PMID:27213398

  1. Nonlinear dynamic modeling for smart material electro-hydraulic actuator development

    Science.gov (United States)

    Larson, John P.; Dapino, Marcelo J.

    2013-03-01

    Smart material electro-hydraulic actuators use hydraulic rectification by one-way check valves to amplify the motion of smart materials, such as magnetostrictives and piezoelectrics, in order to create compact, lightweight actuators. A piston pump driven by a smart material is combined with a hydraulic cylinder to form a self-contained, power-by-wire actuator that can be used in place of a conventional hydraulic system without the need for hydraulic lines and a centralized pump. The performance of an experimental actuator driven by a 12.7 mm diameter, 114 mm length Terfenol-D rod is evaluated over a range of applied input frequencies, loads, and currents. The peak performance achieved is 37 W, moving a 220 N load at a rate of 17 cm/s and producing a blocked pressure of 12.5 MPa. Additional tests are conducted to quantify the dynamic behavior of the one-way reed valves using a scanning laser vibrometer to identify the frequency response of the reeds and the effect of the valve seat and fluid mass loading. A lumped-parameter model is developed for the system that includes valve inertia and fluid response nonlinearities, and the model results are compared with the experimental data.

  2. Design of pneumatic proportional flow valve type 5/3

    Science.gov (United States)

    Laski, P. A.; Pietrala, D. S.; Zwierzchowski, J.; Czarnogorski, K.

    2017-08-01

    In this paper the 5/3-way pneumatic, proportional flow valve was designed and made. Stepper linear actuator was used to move the spool. The valve is controlled by the controlled based on a AVR microcontroller. Virtual model of the valve was created in CAD. The real element was made based on a standard 5/3-way manually actuated valve with hand lever, which was dismounted and replaced by linear stepper motor. All the elements was mounted in a specially made housing. The controller consists of microcontroller Atmega16, integrated circuit L293D, display, two potentiometers, three LEDs and six buttons. Series of research was also conducted. Simulation research were performed using CFD by the Flow Simulation addition to SolidWorks. During the experiments the valve characteristics of flow and pressure was determined.

  3. An Unconventional Inchworm Actuator Based on PZT/ERFs Control Technology.

    Science.gov (United States)

    Liu, Guojun; Zhang, Yanyan; Liu, Jianfang; Li, Jianqiao; Tang, Chunxiu; Wang, Tengfei; Yang, Xuhao

    2016-01-01

    An unconventional inchworm actuator for precision positioning based on piezoelectric (PZT) actuation and electrorheological fluids (ERFs) control technology is presented. The actuator consists of actuation unit (PZT stack pump), fluid control unit (ERFs valve), and execution unit (hydraulic actuator). In view of smaller deformation of PZT stack, a new structure is designed for actuation unit, which integrates the advantages of two modes (namely, diaphragm type and piston type) of the volume changing of pump chamber. In order to improve the static shear yield strength of ERFs, a composite ERFs valve is designed, which adopts the series-parallel plate compound structure. The prototype of the inchworm actuator has been designed and manufactured in the lab. Systematic test results indicate that the displacement resolution of the unconventional inchworm actuator reaches 0.038 μm, and the maximum driving force and velocity are 42 N, 14.8 mm/s, respectively. The optimal working frequency for the maximum driving velocity is 120 Hz. The complete research and development processes further confirm the feasibility of developing a new type of inchworm actuator with high performance based on PZT actuation and ERFs control technology, which provides a reference for the future development of a new type of actuator.

  4. An Unconventional Inchworm Actuator Based on PZT/ERFs Control Technology

    Directory of Open Access Journals (Sweden)

    Guojun Liu

    2016-01-01

    Full Text Available An unconventional inchworm actuator for precision positioning based on piezoelectric (PZT actuation and electrorheological fluids (ERFs control technology is presented. The actuator consists of actuation unit (PZT stack pump, fluid control unit (ERFs valve, and execution unit (hydraulic actuator. In view of smaller deformation of PZT stack, a new structure is designed for actuation unit, which integrates the advantages of two modes (namely, diaphragm type and piston type of the volume changing of pump chamber. In order to improve the static shear yield strength of ERFs, a composite ERFs valve is designed, which adopts the series-parallel plate compound structure. The prototype of the inchworm actuator has been designed and manufactured in the lab. Systematic test results indicate that the displacement resolution of the unconventional inchworm actuator reaches 0.038 μm, and the maximum driving force and velocity are 42 N, 14.8 mm/s, respectively. The optimal working frequency for the maximum driving velocity is 120 Hz. The complete research and development processes further confirm the feasibility of developing a new type of inchworm actuator with high performance based on PZT actuation and ERFs control technology, which provides a reference for the future development of a new type of actuator.

  5. Valve performance concept move from preventive to condition-oriented maintenance

    International Nuclear Information System (INIS)

    Zanner, G.; Kradepohl, P.

    1996-01-01

    As a turnkey supplier of nuclear and fossil power plants, Siemens must pay attention in concentrating, maintaining, and developing the expertise in many areas such as system design, components, materials, quality assurance, and qualification testing within centralized organizations. In the company segment VALVES, Siemens/KWU is staffed with experienced professionals who have serviced the power plant industry for about 25 years. The valve engineers deal with all kinds of valve and actuator-related activities like design ratings, development, qualifications, and ongoing improvements. In this regard, the engineers are involved in nearly all actual problems and suggested solutions through continuing dialogues with utilities, authorities, and vendors of valves and actuators

  6. Valve performance concept move from preventive to condition-oriented maintenance

    Energy Technology Data Exchange (ETDEWEB)

    Zanner, G.; Kradepohl, P.

    1996-12-01

    As a turnkey supplier of nuclear and fossil power plants, Siemens must pay attention in concentrating, maintaining, and developing the expertise in many areas such as system design, components, materials, quality assurance, and qualification testing within centralized organizations. In the company segment VALVES, Siemens/KWU is staffed with experienced professionals who have serviced the power plant industry for about 25 years. The valve engineers deal with all kinds of valve and actuator-related activities like design ratings, development, qualifications, and ongoing improvements. In this regard, the engineers are involved in nearly all actual problems and suggested solutions through continuing dialogues with utilities, authorities, and vendors of valves and actuators.

  7. On-demand liquid-in-liquid droplet metering and fusion utilizing pneumatically actuated membrane valves

    International Nuclear Information System (INIS)

    Lin, Bo-Chih; Su, Yu-Chuan

    2008-01-01

    This paper presents an active emulsification scheme that is capable of producing micro-droplets with desired volumes and compositions on demand. Devices with pneumatically actuated membranes constructed on top of specially designed microfluidic channels are utilized to meter and fuse liquid-in-liquid droplets. By steadily pressurizing a fluid and intermittently blocking its flow, droplets with desired volumes are dispersed into another fluid. Furthermore, droplets from multiple sources are fused together to produce combined droplets with desired compositions. In the prototype demonstration, a three-layer PDMS molding and irreversible bonding process was employed to fabricate the proposed microfluidic devices. For a dispersed-phase flow that is normally blocked by a membrane valve, the relationship between the volume (V) of a metered droplet and the corresponding valve open time (T) is found to be approximately V = kT a , in which k and a are constants determined mainly by the fluid-driving pressures. In addition to the metering device, functional droplet entrapment, fusion and flow-switching devices were also integrated in the system to produce desired combined droplets and deliver them to intended destinations upon request. As such, the demonstrated microfluidic system could potentially realize the controllability on droplet volume, composition and motion, which is desired for a variety of chemical and biological applications

  8. Piezoelectric-hydraulic pump based band brake actuation system for automotive transmission control

    Science.gov (United States)

    Kim, Gi-Woo; Wang, K. W.

    2007-04-01

    The actuation system of friction elements (such as band brakes) is essential for high quality operations in modern automotive automatic transmissions (in short, ATs). The current band brake actuation system consists of several hydraulic components, including the oil pump, the regulating valve and the control valves. In general, it has been recognized that the current AT band brake actuation system has many limitations. For example, the oil pump and valve body are relatively heavy and complex. Also, the oil pumps induce inherently large drag torque, which affects fuel economy. This research is to overcome these problems of the current system by exploring the utilization of a hybrid type piezo-hydraulic pump device for AT band brake control. This new actuating system integrates a piezo-hydraulic pump to the input of the band brake. Compared with the current systems, this new actuator features much simpler structure, smaller size, and lower weight. This paper describes the development, design and fabrication of the new stand-alone prototype actuator for AT band brake control. An analytical model is developed and validated using experimental data. Performance tests on the hardware and system simulations utilizing the validated model are performed to characterize the new prototype actuator. It is predicted that with increasing of accumulator pressure and driving frequency, the proposed prototype actuating system will satisfy the band brake requirement for AT shift control.

  9. Optothermally actuated capillary burst valve

    DEFF Research Database (Denmark)

    Eriksen, Johan; Bilenberg, Brian; Kristensen, Anders

    2017-01-01

    be burst by raising the temperature due to the temperature dependence of the fluid surface tension. We address individual valves by using a local heating platform based on a thin film of near infrared absorber dye embedded in the lid used to seal the microfluidic device [L. H. Thamdrup et al., Nano Lett...

  10. An air-pressure-free elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis

    International Nuclear Information System (INIS)

    Jung, Wooseok; Barrett, Matthew; Brooks, Carla; Zenhausern, Frederic; Rivera, Andrew; Birdsell, Dawn N; Wagner, David M

    2015-01-01

    We present a new elastomeric valve for integrated nucleic acid analysis by capillary electrophoresis. The valve functions include metering to capture a designated volume of biological sample into a polymerase chain reaction (PCR) chamber, sealing to preserve the sample during PCR cycling, and transfer of the PCR-products and on-chip formamide post-processing for the analysis of DNA fragments by capillary gel electrophoresis. This new valve differs from prior art polydimethylsiloxane (PDMS) valves in that the valve is not actuated externally by air-pressure or vacuum so that it simplifies a DNA analysis system by eliminating the need for an air-pressure or vacuum source, and off-cartridge solenoid valves, control circuit boards and software. Instead, the new valve is actuated by a thermal cycling peltier assembly integrated within the hardware instrument that tightly comes in contact with a microfluidic cartridge for thermal activation during PCR, so that it spontaneously closes the valve without an additional actuator system. The valve has bumps in the designated locations so that it has a self-alignment that does not require precise alignment of a valve actuator. Moreover, the thickness of the new valve is around 600 μm with an additional bump height of 400 μm so that it is easy to handle and very feasible to fabricate by injection molding compared to other PDMS valves whose thicknesses are around 30–100 μm. The new valve provided over 95% of metering performance in filling the fixed volume of the PCR chamber, preserved over 97% of the sample volume during PCR, and showed very comparable capillary electrophoresis peak heights to the benchtop assay tube controls with very consistent transfer volume of the PCR-product and on-chip formamide. The new valve can perform a core function for integrated nucleic acid analysis by capillary electrophoresis. (paper)

  11. Characteristic analysis and experiment of pneumatic servo valve

    International Nuclear Information System (INIS)

    Kim, Dong Soo; Lee, Won Hee; Choi, Byung Oh

    2004-01-01

    Electro-pneumatic servo valve is an electro-mechanical device which converts electric signals into a proper pneumatic flow rate or pressure. In order to improve the overall performance of pneumatic servo systems, electro-pneumatic servo valves are required, which have fast dynamic characteristics, no air leakage at a null point, and can be fabricated at a low-cost. The first objective of this research is to design and to fabricate a new electro-pneumatic servo valve which satisfies the above-mentioned requirements. In order to design the mechanism of the servo valve optimally, the flow inside the valve depending upon the position of spool was analyzed variously, and on the basis of such analysis results, the valve mechanism, which was formed by combination of the spool and the sleeve, was designed and manufactured. And a tester for conducting an overall performance test was designed and manufactured, and as a result of conducting the flow rate test, the pressure test and the frequency test on the developed pneumatic servo valve

  12. Investigation on the Effects of Internal EGR by Variable Exhaust Valve Actuation with Post Injection on Auto-ignited Combustion and Emission Performance

    Directory of Open Access Journals (Sweden)

    Insu Cho

    2018-04-01

    Full Text Available Variable valve mechanisms are usually applied to a gasoline combustion engine to improve its power performance by controlling the amount of intake air according to the operating load. These mechanisms offer one possibility of resolving the conflict of objectives between a further reduction of raw emissions and an improvement in fuel efficiency. In recent years, variable valve control systems have become extremely important in the diesel combustion engine. Importantly, it has been shown that there are several potential benefits of applying variable valve timing (VVT to a compression ignition engine. Valve train variability could offer one option to achieve the reduction goals of engine-out emissions and fuel consumption. The aim of this study was to investigate the effects on part load combustion and emission performance of internal exhaust gas recirculation (EGR by variable exhaust valve lift actuation using a cam-in-cam system, which is an electronically variable valve device with a variable inside cam retarded to about 30 degrees. Numerical simulation based on GT-POWER has been performed to predict the NOx reduction strategy at the part load operating point of 1200 rpm in a four-valve diesel engine. A GT-POWER model of a common-rail direct injection engine with internal EGR was built and verified with experimental data. As a result, large potential for reducing NOx emissions through the use of exhaust valve control has been identified. Namely, it is possible to utilize heat efficiently as recompression of retarded post injection with downscaled specification of the exhaust valve rather than the intake valve, even if the CIC V1 condition with a reduction of the exhaust valve has a higher internal EGR rate of about 2% compared to that of the CIC V2 condition.

  13. LOFT pressurizer safety: relief valve reliability

    Energy Technology Data Exchange (ETDEWEB)

    Brown, E.S.

    1978-01-18

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice.

  14. LOFT pressurizer safety: relief valve reliability

    International Nuclear Information System (INIS)

    Brown, E.S.

    1978-01-01

    The LOFT pressurizer self-actuating safety-relief valves are constructed to the present state-of-the-art and should have reliability equivalent to the valves in use on PWR plants in the U.S. There have been no NRC incident reports on valve failures to lift that would challenge the Technical Specification Safety Limit. Fourteen valves have been reported as lifting a few percentage points outside the +-1% Tech. Spec. surveillance tolerance (9 valves tested over and 5 valves tested under specification). There have been no incident reports on failures to reseat. The LOFT surveillance program for assuring reliability is equivalent to nuclear industry practice

  15. Osmotic actuation for microfluidic components in point-of-care applications

    KAUST Repository

    Chen, Yu-Chih; Ingram, Patrick; Lou, Xia; Yoon, Euisik

    2013-01-01

    at low cost. In this work, we report two key active components actuated by osmotic mechanism for total integrated microfluidic system. For the proof of concept, we have demonstrated valve actuation, which can maintain stable ON/OFF switching operations

  16. Development of advanced diagnostic technologies for motor-operated valves

    International Nuclear Information System (INIS)

    Hegi, Kotaro; Shimizu, Shunichi; Higuma, Koji; Nishino, Koji; Osaki, Kenji; Watanabe, Kazumi; Hamano, Frank

    2010-01-01

    As use of condition-based maintenance is allowed in the new regulatory inspection system employed in Japan's nuclear power plants in 2009, development of advanced diagnostic technologies for motor-operated valves (MOVs) is now required. This report discusses advanced technologies in valve-setup verification, valve performance evaluation, monitoring of valve/actuator conditions by performance diagnostic system and moreover detection of stem crack by ultrasonic diagnostic system. (author)

  17. Effects of aging and service wear on main steam isolation valves and valve operators

    International Nuclear Information System (INIS)

    Clark, R.L.

    1996-03-01

    In recent years main steam isolation valve (MSIV operating problems have resulted in significant operational transients (e.g., spurious reactor trips, steam generator dry out, excessive valve seat leakage), increased cost, and decreased plant availability. A key ingredient to an engineering-oriented reliability improvement effort is a thorough understanding of relevant historical experience. A detailed review of historical failure data available through the Institute of Nuclear Power Operation's Nuclear Plant Reliability Data System has been conducted for several types of MSIVs and valve operators for both boiling-water reactors and pressurized-water reactors. The focus of this review is on MSIV failures modes, actuator failure modes, consequences of failure on plant operations, method of failure detection, and major stressors affecting both valves and valve operators

  18. Non-linear control of a hydraulic piezo-valve using a generalized Prandtl-Ishlinskii hysteresis model

    OpenAIRE

    Stefanski, Frederik; Minorowicz, Bartosz; Persson, Johan; Plummer, Andrew; Bowen, Christopher

    2017-01-01

    The potential to actuate proportional flow control valves using piezoelectric ceramics or other smart materials has been investigated for a number of years. Although performance advantages compared to electromagnetic actuation have been demonstrated, a major obstacle has proven to be ferroelectric hysteresis, which is typically 20% for a piezoelectric actuator. In this paper, a detailed study of valve control methods incorporating hysteresis compensation is made for the first time. Experiment...

  19. Design of a MRI-compatible dielectric elastomer powered jet valve

    Science.gov (United States)

    Proulx, Sylvain; Chouinard, Patrick; Lucking Bigue, Jean-Philippe; Miron, Geneviève; Plante, Jean-Sébastien

    2011-04-01

    Binary Pneumatic Air Muscles (PAM) arranged in an elastically-averaged configuration can form a cost effective solution for Magnetic Resonance Imaging (MRI) guided robotic interventions like prostate cancer biopsies and brachytherapies. Such binary pneumatic manipulators require about 10 to 20 MRI-compatible valves to control the pressure state of each PAM. In this perspective, this paper presents the design of a novel dielectric elastomer actuator (DEA) driven jet-valve to control the states of the PAMs. DEAs are MRI compatible actuators that are well suited to the simplicity and cost-effectiveness of the binary manipulation approach. The key feature of the proposed valve design is its 2 stages configuration in which the pilot stage is moved with minimal mechanical friction by a rotary antagonistic DEA made with acrylic polymer films. The prismatic geometry also integrates the jet nozzle within the DEA volume to provide a compact embodiment with a reduced number of parts. The low actuation stretches enabled by the rotary configuration minimize viscoelastic losses, and thus, maximize the frequency response of the actuator while maximizing its reliability potential. The design space of the proposed jet valve is studied using an Ogden hyperelastic model and the valve dynamics is predicted with a 1D Bergstrom-Boyce viscoelastic model. Altogether, the low friction of the pilot stage and optimized DEA dynamics provide an experimental shifting time of the complete assembly in the 200-300ms range. Results from this work suggest that the DEA driven jet valve has great potential for switching a large number of pneumatic circuits in a MRI environment with a compact, low cost and simple embodiment.

  20. A review of design and modeling of magnetorheological valve

    Science.gov (United States)

    Abd Fatah, Abdul Yasser; Mazlan, Saiful Amri; Koga, Tsuyoshi; Zamzuri, Hairi; Zeinali, Mohammadjavad; Imaduddin, Fitrian

    2015-01-01

    Following recent rapid development of researches in utilizing Magnetorheological (MR) fluid, a smart material that can be magnetically controlled to change its apparent viscosity instantaneously, a lot of applications have been established to exploit the benefits and advantages of using the MR fluid. One of the most important applications for MR fluid in devices is the MR valve, where it uses the popular flow or valve mode among the available working modes for MR fluid. As such, MR valve is widely applied in a lot of hydraulic actuation and vibration reduction devices, among them are dampers, actuators and shock absorbers. This paper presents a review on MR valve, discusses on several design configurations and the mathematical modeling for the MR valve. Therefore, this review paper classifies the MR valve based on the coil configuration and geometrical arrangement of the valve, and focusing on four different mathematical models for MR valve: Bingham plastic, Herschel-Bulkley, bi-viscous and Herschel-Bulkley with pre-yield viscosity (HBPV) models for calculating yield stress and pressure drop in the MR valve. Design challenges and opportunities for application of MR fluid and MR valve are also highlighted in this review. Hopefully, this review paper can provide basic knowledge on design and modeling of MR valve, complementing other reviews on MR fluid, its applications and technologies.

  1. Process to repair a steam generator tube by inserting a tubular sleeve and the associated sleeve

    International Nuclear Information System (INIS)

    Gaudin, J.P.

    1986-01-01

    The tubular sleeve is introduced in the tube and is mechanically expanded inside the tube plate, and is diametrally expanded at its upper part within the tube and outside the tube plate. Tightness is ensured by brazing the end part of the sleeve within the tube. The end part of the sleeve is brazed by melting of brazing metal previously applied to the outer surface of the sleeve of its end region. The invention applies more particularly to steam generators of pressurized water nuclear reactors [fr

  2. Integral isolation valve systems for loss of coolant accident protection

    Science.gov (United States)

    Kanuch, David J.; DiFilipo, Paul P.

    2018-03-20

    A nuclear reactor includes a nuclear reactor core comprising fissile material disposed in a reactor pressure vessel having vessel penetrations that exclusively carry flow into the nuclear reactor and at least one vessel penetration that carries flow out of the nuclear reactor. An integral isolation valve (IIV) system includes passive IIVs each comprising a check valve built into a forged flange and not including an actuator, and one or more active IIVs each comprising an active valve built into a forged flange and including an actuator. Each vessel penetration exclusively carrying flow into the nuclear reactor is protected by a passive IIV whose forged flange is directly connected to the vessel penetration. Each vessel penetration carrying flow out of the nuclear reactor is protected by an active IIV whose forged flange is directly connected to the vessel penetration. Each active valve may be a normally closed valve.

  3. Studies to demonstrate the adequacy of testing results of the qualification tests for the actuator of main steam safety relive valves (MSSRV) in an advanced boiling water reactor (ABWR)

    International Nuclear Information System (INIS)

    Gou, P.F.; Patel, R.; Curran, G.; Henrie, D.; Solorzano, E.

    2005-01-01

    This paper presents several studies performed to demonstrate that the testing results from the qualification tests for the actuator of the Main Steam Safety Relief Valves (MSSRV; also called SRV in this paper) in GE's Advanced Boiling Water Reactor (ABWR) are in compliance with the qualification guidelines stipulated in the applicable IEEE standards. The safety-related function of the MSSRV is to relieve pressure in order to protect the reactor pressure vessel from over-pressurization condition during normal operation and design basis events. In order to perform this function, the SRV must actuate at a given set pressure while maintaining the pressure and structural integrity of the SRV. The valves are provided with an electro-pneumatic actuator assembly that opens the valve upon receipt of an automatic or manually initiated electric signal to allow depressurization of the reactor pressure vessel (RPV). To assure the SRV can perform its intended safety related functions properly, qualification tests are needed in addition to analysis, to demonstrate that the SRV can withstand the specified environmental, dynamic and seismic design basis conditions without impairing its safety related function throughout their installed life under the design conditions including postulated design basis events such as OBE loads and Faulted (SSE) events. The guidelines used for the test methods, procedures and acceptance criteria for the qualification tests are established in IEEE std 344-1987 and IEEE std 382-1985. In the qualification tests, the specimen consists of the actuator, control valve assembly, limit switches, and limit switch support structure. During the functional, dynamic and seismic tests, the test specimen was mounted on a SRV. Qualification of safety related equipment to meet the guidelines of the IEEE standards is typically a two-step process: 1) environmental aging and 2) design basis events qualification. The purpose of the first step is to put the equipment in an

  4. NRC Information No. 90-21: Potential failure of motor-operated butterfly valves to operate because valve seat friction was underestimated

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1992-01-01

    In October 1988, at Catawba Nuclear Station Unit 1, a motor-operated butterfly valve in the service water system failed to open under high differential pressure conditions. The licensee concluded that the valve manufacturer, BIF/General Signal Corporation, had underestimated the degree to which the material used in the valve seat would harden with age (the responsibility for these valves has been transferred to Paul-Munroe Enertech). This underestimation of the age hardening had led the manufacturer to assume valve seat friction forces that were less than the actual friction forces in the installed valve. To overcome the larger-than-anticipated friction forces, the licensee's engineering staff recommended the open torque switch for 56 butterfly valves be reset to the maximum allowable value. The systems in which these valves are located include the component cooling water system, service water system, and various ventilation systems. By July 26, 1989, the torque switch adjustments were completed at Catawba Units 1 and 2. After reviewing the final settings, the licensee's engineering staff determined that the actuators for three butterfly valves in the component cooling water system might not be able to overcome the friction forces resulting from maximum seat hardening. On December 13, 1989, the licensee determined that the failure of these BIF/General Signal motor-operated valves (MOVs) could cause a loss of cooling water to residual heat removal system heat exchangers. To resolve the concern regarding the operability of these BIF/General Signal valves, a torque switch bypass was installed on two of the actuators to allow full motor capability during opening

  5. Fabrication of micro metallic valve and pump

    Science.gov (United States)

    Yang, Ming; Kabasawa, Yasunari; Ito, Kuniyoshi

    2010-03-01

    Fabrication of micro devices by using micro metal forming was proposed by the authors. We developed a desktop servo-press machine with precise tooling system. Precise press forming processes including micro forging and micro joining has been carried out in a progressive die. In this study, micro metallic valve and pump were fabricated by using the precise press forming. The components are made of sheet metals, and assembled in to a unit in the progressive die. A micro check-valve with a diameter of 3mm and a length of 3.2mm was fabricated, and the property of flow resistance was evaluated. The results show that the check valve has high property of leakage proof. Since the valve is a unit parts with dimensions of several millimeters, it has advantage to be adapted to various pump design. Here, two kinds of micro pumps with the check-valves were fabricated. One is diaphragm pump actuated by vibration of the diaphragm, and another is tube-shaped pump actuated by resonation. The flow quantities of the pumps were evaluated and the results show that both of the pumps have high pumping performance.

  6. Evaluation and compensation of steady gas flow force on the high-pressure electro-pneumatic servo valve direct-driven by voice coil motor

    International Nuclear Information System (INIS)

    Li, Baoren; Gao, Longlong; Yang, Gang

    2013-01-01

    Highlights: ► A novel energy saving high-pressure electro-pneumatic servo valve is presented. ► An evaluated method for steady gas flow forces on pneumatic valves is proposed. ► Gas jet angles at the orifices for the valve are larger than 69° commonly used. ► The steady gas flow force is strongly nonlinear with valve opening. ► The steady gas flow force is compensated and the aim at energy saving is realized. - Abstract: A novel voice coil motor (VCM) direct drive single stage high-pressure pneumatic servo valve is designed, and then the steady gas flow force acting on the spool of the servo valve is investigated by numerical simulation and experimental methods in this paper. At present, many studies about flow force are concentrated mainly on hydraulic valves, but rarely on pneumatic valves. However, the velocity of gas is up to sonic when high-pressure gas flows through the servo valve orifice. And therefore, the steady gas flow force, generated by high pressure and high speed gas flow, cannot be neglected and is an important disturbance for the VCM direct-drive single stage high-pressure pneumatic servo valve. Consequently, the numerical simulation with computational fluid dynamics (CFD) is adopted to analyze the flow filed, jet angles, and steady gas flow forces for the servo valve with different valve openings and inlet pressures. The experimental study is performed to evaluate and confirm the numerical analysis. Then the compensated approach is proposed to reduce the steady gas flow force for the servo valve, changing the angle of non-metering port designed in the valve sleeve to the spool axis. The results demonstrate that the presented numerical analysis method is validated, the gas jet angle for the servo valve orifice is more than 69° and varies with different spool openings, and the steady gas flow force is nonlinear with valve opening and linear with inlet pressure when the outlet boundary is atmospheric pressure. Moreover, the steady gas

  7. Indigeneous design and development of differential pressure reducing valves for PHWRs (Paper No. 055)

    International Nuclear Information System (INIS)

    Soni, N.L.; Agrawal, R.C.; Chandra, Rajesh

    1987-02-01

    On load fuelling of Pressurised Heavy Water Reactors (PHWRs) is being achieved with the help of Fuelling Machine (F/M). Various actuations are to be carried out inside the F/M magazine pressure housing with the help of high pressure water hydraulic actuators. A constant differential pressure is required to be maintained between pressurized magazine housing and the actuators-supply line for proper operation of the actuators which are to be located inside it. This is achieved with the help of the Differential Pressure Reducing Valve (DPRV). So far these valves have been procured only from a single foreign supplier. In March 1980, the price of each valve was US dollars 3100.00. Dependence on a single foreign supplier may create problems of timely procurement. An effort was made to design and manufacture the DPRV indigensouly meeting the stringent specifications. Theoretical study of single acting DPRV was carried out and design criteria were established. The valve was tested for its performance and was found satisfactory. (author). 8 figs

  8. Design, fabrication and characterization of an arrayable all-polymer microfluidic valve employing highly magnetic rare-earth composite polymer

    International Nuclear Information System (INIS)

    Rahbar, Mona; Gray, Bonnie L; Shannon, Lesley

    2016-01-01

    We present a new magnetically actuated microfluidic valve that employs a highly magnetic composite polymer (M-CP) containing rare-earth hard-magnetic powder for its actuating element and for its valve seat. The M-CP offers much higher magnetization compared to the soft-magnetic, ferrite-based composite polymers typically used in microfluidic applications. Each valve consists of a permanently magnetized M-CP flap and valve seat mounted on a microfluidic channel system fabricated in poly(dimethylsiloxane) (PDMS). Each valve is actuated under a relatively small external magnetic field of 80 mT provided by a small permanent magnet mounted on a miniature linear actuator. The performance of the valve with different flap thicknesses is characterized. In addition, the effect of the magnetic valve seat on the valve’s performance is also characterized. It is experimentally shown that a valve with a 2.3 mm flap thickness, actuated under an 80 mT magnetic field, is capable of completely blocking liquid flow at a flow rate of 1 ml min −1 for pressures up to 9.65 kPa in microfluidic channels 200 μ m wide and 200 μ m deep. The valve can also be fabricated into an array for flow switching between multiple microfluidic channels under continuous flow conditions. The performance of arrays of valves for flow routing is demonstrated for flow rates up to 5 ml min −1 with larger microfluidic channels of up to 1 mm wide and 500 μ m deep. The design of the valves is compatible with other commonly used polymeric microfluidic components, as well as other components that use the same novel permanently magnetic composite polymer, such as our previously reported cilia-based mixing devices. (paper)

  9. Novel passive normally closed microfluidic valve

    CSIR Research Space (South Africa)

    Land, K

    2009-09-01

    Full Text Available ’ represents the distance by which the membrane is depressed before actuation. This stretches the membrane to give it a pre-tension. Thus, when the pressure is removed from the inlet, the membrane returns to its original position, thereby closing the valve.... This also determines the pressure, pcritical, required to depress the membrane for actuation. Actuation occurs once the pressure from the input fluid reaches pcritical, the membrane is depressed and fluid flows freely from the inlet to the outlet. A...

  10. Flow restrictor silicon membrane microvalve actuated by optically controlled paraffin phase transition

    International Nuclear Information System (INIS)

    Kolari, K; Havia, T; Stuns, I; Hjort, K

    2014-01-01

    Restrictor valves allow proportional control of fluid flow but are rarely integrated in microfluidic systems. In this study, an optically actuated silicon membrane restrictor microvalve is demonstrated. Its actuation is based on the phase transition of paraffin, using a paraffin wax mixed with a suitable concentration of optically absorbing nanographite particles. Backing up the membrane with oil (the melted paraffin) allows for a compliant yet strong contact to the valve seat, which enables handling of high pressures. At flow rates up to 30 µL min −1 and at a pressure of 2 bars, the valve can successfully be closed and control the flow level by restriction. The use of this paraffin composite as an adhesive layer sandwiched between the silicon valve and glass eases fabrication. This type of restrictor valve is best suited for high pressure, low volume flow silicon-based nanofluidic systems. (paper)

  11. Grasp Assist Device with Shared Tendon Actuator Assembly

    Science.gov (United States)

    Ihrke, Chris A. (Inventor); Bergelin, Bryan J. (Inventor); Bridgwater, Lyndon (Inventor)

    2015-01-01

    A grasp assist device includes a glove with first and second tendon-driven fingers, a tendon, and a sleeve with a shared tendon actuator assembly. Tendon ends are connected to the respective first and second fingers. The actuator assembly includes a drive assembly having a drive axis and a tendon hook. The tendon hook, which defines an arcuate surface slot, is linearly translatable along the drive axis via the drive assembly, e.g., a servo motor thereof. The flexible tendon is routed through the surface slot such that the surface slot divides the flexible tendon into two portions each terminating in a respective one of the first and second ends. The drive assembly may include a ball screw and nut. An end cap of the actuator assembly may define two channels through which the respective tendon portions pass. The servo motor may be positioned off-axis with respect to the drive axis.

  12. System for detecting operating errors in a variable valve timing engine using pressure sensors

    Science.gov (United States)

    Wiles, Matthew A.; Marriot, Craig D

    2013-07-02

    A method and control module includes a pressure sensor data comparison module that compares measured pressure volume signal segments to ideal pressure volume segments. A valve actuation hardware remedy module performs a hardware remedy in response to comparing the measured pressure volume signal segments to the ideal pressure volume segments when a valve actuation hardware failure is detected.

  13. Root cause analysis of thermal sleeve separation

    Energy Technology Data Exchange (ETDEWEB)

    Jo, J. C.; Jhung, M. J.; Yu, S. O.; Kim, H. J.; Yune, Y. K.; Park, J. Y

    2006-01-15

    Thermal sleeves in the shape of thin wall cylinder seated inside the nozzle part of each Safety Injection (SI) line at Pressurized Water Reactors (PWRs) have such functions as prevention and relief of potential excessive transient thermal stress in the wall of SI line nozzle part which is initially heated up with hot water flowing in the primary coolant piping system when cold water is injected into the system through the SI nozzles during the SI operation mode. Recently, mechanical failures that the sleeves were separated from the SI branch pipe and fell into the connected cold leg main pipe occurred in sequence at some typical PWR plants in Korea. To find out the root cause of thermal sleeve breakaway failures, the flow situation in the junction of primary coolant main pipe and SI branch pipe, and the vibration modal characteristics of the thermal sleeve are investigated in detail by using both Computational Fluid Dynamic (CFD) code and structure analysis finite element code. As the results, the transient response in fluid force exerting on the local part of thermal sleeve wall surface to the primary coolant flow through the pipe junction area during the normal reactor operation mode shows oscillatory characteristics with frequencies ranging from 17 to 18, which coincide with one of the lower mode natural frequencies of thermal sleeve having a pinned support condition on the circumferential prominence on the outer surface of thermal sleeve which is put into the circumferential groove on the inner surface of SI nozzle at the mid-height of the thermal sleeve. In addition, the variation of force on the thermal sleeve surface yields alternating torques in the directions of two rectangular axes which are perpendicular to the longitudinal axis of cylindrical thermal sleeve, which cause rolling, pitching and rotating motions of the thermal sleeve. Consequently, it is seen that this flow situation surrounding the thermal sleeve during the normal reactor operation can

  14. Non-linear control of a hydraulic piezo-valve using a generalised Prandtl-Ishlinskii hysteresis model

    Science.gov (United States)

    Stefanski, Frederik; Minorowicz, Bartosz; Persson, Johan; Plummer, Andrew; Bowen, Chris

    2017-01-01

    The potential to actuate proportional flow control valves using piezoelectric ceramics or other smart materials has been investigated for a number of years. Although performance advantages compared to electromagnetic actuation have been demonstrated, a major obstacle has proven to be ferroelectric hysteresis, which is typically 20% for a piezoelectric actuator. In this paper, a detailed study of valve control methods incorporating hysteresis compensation is made for the first time. Experimental results are obtained from a novel spool valve actuated by a multi-layer piezoelectric ring bender. A generalised Prandtl-Ishlinskii model, fitted to experimental training data from the prototype valve, is used to model hysteresis empirically. This form of model is analytically invertible and is used to compensate for hysteresis in the prototype valve both open loop, and in several configurations of closed loop real time control system. The closed loop control configurations use PID (Proportional Integral Derivative) control with either the inverse hysteresis model in the forward path or in a command feedforward path. Performance is compared to both open and closed loop control without hysteresis compensation via step and frequency response results. Results show a significant improvement in accuracy and dynamic performance using hysteresis compensation in open loop, but where valve position feedback is available for closed loop control the improvements are smaller, and so conventional PID control may well be sufficient. It is concluded that the ability to combine state-of-the-art multi-layer piezoelectric bending actuators with either sophisticated hysteresis compensation or closed loop control provides a route for the creation of a new generation of high performance piezoelectric valves.

  15. AREVA's innovative solutions for valve diagnostics and in-situ valve repair

    International Nuclear Information System (INIS)

    Damies, H.; Breitenberger, U.; Munoz, L.; Kostroun, F.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions can support that in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. More than 25 years of experience in various plants worldwide show that application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. With the innovative AVARIS technology an in-situ valve repair is possible. It has the unique ability to conduct several steps in-situ, to maintain the sealing seat of gate or check valves. By applying AVARIS, the valve is restored in its original state, the system remains unchanged. Thus, all original documents remain valid and applicable. In comparison to previous procedures like cutting valves out of the pipeline and repairing hard facings or damaged seal seats in a separate workshop or alternatively replacement by a new valve body the new AVARIS technology avoids costs, risk and effort. (author)

  16. Valve-sparing and valve-replacing techniques for aortic root replacement in patients with Marfan syndrome: Analysis of early outcome.

    Science.gov (United States)

    Volguina, Irina V; Miller, D Craig; LeMaire, Scott A; Palmero, Laura C; Wang, Xing Li; Connolly, Heidi M; Sundt, Thoralf M; Bavaria, Joseph E; Dietz, Harry C; Milewicz, Dianna M; Coselli, Joseph S

    2009-05-01

    A prospective, international registry study was initiated to provide contemporary comparative data on short-term clinical outcomes after aortic valve-sparing and aortic valve-replacing root operations in patients with Marfan syndrome. The purpose of this initial report is to describe the study design and to compare early outcomes in the first 151 enrolled patients. We assessed 30-day outcomes in 151 patients who met strict Ghent diagnostic criteria for Marfan syndrome and underwent aortic root replacement with either valve-replacing (n = 46) or valve-sparing techniques (n = 105) at one of 18 participating centers. In the valve replacement group, a mechanical composite valve graft was used in 39 (85%) patients and a bioprosthetic valve in 7 (15%). In the valve-sparing group, David V procedures were performed in 57 (54%) patients, David I in 38 (36%), David IV in 8 (8%), Florida sleeve in 1 (1%), and Yacoub remodeling in 1 (1%). No in-hospital or 30-day deaths occurred. Despite longer crossclamp and cardiopulmonary bypass times in the valve-sparing group, there were no significant between-group differences in postoperative complications. Thirty-day valve-related complications occurred in 2 (4%) patients undergoing valve replacement and in 3 (3%) undergoing valve-sparing procedures (P = .6). The analysis of early outcomes revealed that valve-sparing techniques were the most common approach to root replacement in patients with Marfan syndrome in these centers. The complexity of valve-sparing root replacement did not translate into any demonstrable adverse early outcomes. Subsequent analysis will compare the 3-year durability of these two surgical approaches.

  17. Enhancement of pressurizer safety valve operability by seating design improvement

    International Nuclear Information System (INIS)

    Moisidis, N.T.; Ratiu, M.D.

    1994-01-01

    Operating conditions specific to Pressurizer Safety Valves (PSVs) have led to numerous problems and have caused industry and NRC concerns regarding the adequacy of spring loaded self-actuated safety valves for Reactor Coolant System (RCS) overpressure protection. Specific concerns are: setpoint drift, spurious actuations and leakage. Based on testing and valve construction analysis of a Crosby model 6M6 PSV, it was established that the primary contributor to the valve problems is a susceptibility to weak seating. To eliminate spring instability, a new spring washer was designed, which guides the spring and precludes its rotation from the reference installed position. Results of tests performed on a prototype PSV equipped with the modified upper spring washer has shown significant improvements in valve operability and a consistent setpoint reproducibility to less than ±1% of the PSV setpoint (testing of baseline, unmodified valve, resulted in a setpoint drift of ±2%). Enhanced valve operability will result in a significant decrease in operating and maintenance costs associated with valve maintenance and testing. In addition, the enhanced setpoint reproducibility will allow the development of a nitrogen to steam correlation for future in-house PSV testing which will result in further reductions in costs associated with valve testing

  18. Optimization of a pressure control valve for high power automatic transmission considering stability

    Science.gov (United States)

    Jian, Hongchao; Wei, Wei; Li, Hongcai; Yan, Qingdong

    2018-02-01

    The pilot-operated electrohydraulic clutch-actuator system is widely utilized by high power automatic transmission because of the demand of large flowrate and the excellent pressure regulating capability. However, a self-excited vibration induced by the inherent non-linear characteristics of valve spool motion coupled with the fluid dynamics can be generated during the working state of hydraulic systems due to inappropriate system parameters, which causes sustaining instability in the system and leads to unexpected performance deterioration and hardware damage. To ensure a stable and fast response performance of the clutch actuator system, an optimal design method for the pressure control valve considering stability is proposed in this paper. A non-linear dynamic model of the clutch actuator system is established based on the motion of the valve spool and coupling fluid dynamics in the system. The stability boundary in the parameter space is obtained by numerical stability analysis. Sensitivity of the stability boundary and output pressure response time corresponding to the valve parameters are identified using design of experiment (DOE) approach. The pressure control valve is optimized using particle swarm optimization (PSO) algorithm with the stability boundary as constraint. The simulation and experimental results reveal that the optimization method proposed in this paper helps in improving the response characteristics while ensuring the stability of the clutch actuator system during the entire gear shift process.

  19. Framatome technologies successfully performs SG re-sleeving at Kewaunee

    International Nuclear Information System (INIS)

    Anon.

    1997-01-01

    Framatome Technologies teamed with ABB-CE (Connecticut) to remove previously installed sleeves from the Kewaunee nuclear power stations steam generator tubes and install new sleeves. Recent inspections indicated problems at the upper joint of many of the previous sleeves. The process involved removing most of the hydraulic expansion joint (HEJ) sleeve, expanding the sleeve remnant and the tube section at the upper joint, and installing a TIG-welded sleeve that bridges the problem portion of the tube that the HEJ sleeve covered

  20. Design of the Modular Pneumatic Valve Terminal

    Directory of Open Access Journals (Sweden)

    Jakub E. TAKOSOGLU

    2015-11-01

    Full Text Available The paper presents design of the modular pneumatic valve terminal, which was made on the basis of the patent application No A1 402905 „A valve for controlling fluid power drives, specially for pneumatic actuators, and the control system for fluid power drives valves”. The authors describe a method of operation of the system with double-acting valve and 5/2 (five ways and two position valve. Functions of the valve, and an example of application of the valve terminal in the production process were presented. 3D solid models of all the components of the valve were made. The paper presents a complete 3D model of the valve in various configurations. Using CAD-embedded SOLIDWORKS Flow Simulation computational fluid dynamics CFD analysis was also carried out of compressed air flow in the ways of the valve elements

  1. Investigations on Actuator Dynamics through Theoretical and Finite Element Approach

    Directory of Open Access Journals (Sweden)

    Somashekhar S. Hiremath

    2010-01-01

    Full Text Available This paper gives a new approach for modeling the fluid-structure interaction of servovalve component-actuator. The analyzed valve is a precision flow control valve-jet pipe electrohydraulic servovalve. The positioning of an actuator depends upon the flow rate from control ports, in turn depends on the spool position. Theoretical investigation is made for No-load condition and Load condition for an actuator. These are used in finite element modeling of an actuator. The fluid-structure-interaction (FSI is established between the piston and the fluid cavities at the piston end. The fluid cavities were modeled with special purpose hydrostatic fluid elements while the piston is modeled with brick elements. The finite element method is used to simulate the variation of cavity pressure, cavity volume, mass flow rate, and the actuator velocity. The finite element analysis is extended to study the system's linearized response to harmonic excitation using direct solution steady-state dynamics. It was observed from the analysis that the natural frequency of the actuator depends upon the position of the piston in the cylinder. This is a close match with theoretical and simulation results. The effect of bulk modulus is also presented in the paper.

  2. Advantages of butterfly valves for power plants

    International Nuclear Information System (INIS)

    Lapadat, J.T.

    1977-01-01

    Butterfly valves are increasingly used in nuclear power plants. They are used in CANDU reactors for class 2 and 3 service, to provide emergency and tight shutoff valves for all inlets and outlets of heat exchangers and all calandria penetrations. Guidelines for meeting nuclear power plant valve specifications are set out in ASME Section 3, Nuclear Power Plant Components. Some details of materials of construction, type of actuator, etc., for various classes of nuclear service are tabulated in the present article. The 'fishtail' butterfly valve is an improved design with reduced drag, as is illustrated and explained. (N.D.H.)

  3. Fully Soft 3D-Printed Electroactive Fluidic Valve for Soft Hydraulic Robots.

    Science.gov (United States)

    Zatopa, Alex; Walker, Steph; Menguc, Yigit

    2018-06-01

    Soft robots are designed to utilize their compliance and contortionistic abilities to both interact safely with their environment and move through it in ways a rigid robot cannot. To more completely achieve this, the robot should be made of as many soft components as possible. Here we present a completely soft hydraulic control valve consisting of a 3D-printed photopolymer body with electrorheological (ER) fluid as a working fluid and gallium-indium-tin liquid metal alloy as electrodes. This soft 3D-printed ER valve weighs less than 10 g and allows for onboard actuation control, furthering the goal of an entirely soft controllable robot. The soft ER valve pressure-holding capabilities were tested under unstrained conditions, cyclic valve activation, and the strained conditions of bending, twisting, stretching, and indentation. It was found that the max holding pressure of the valve when 5 kV was applied across the electrodes was 264 kPa, and that the holding pressure deviated less than 15% from the unstrained max holding pressure under all strain conditions except for indentation, which had a 60% max pressure increase. In addition, a soft octopus-like robot was designed, 3D printed, and assembled, and a soft ER valve was used to stop the fluid flow, build pressure in the robot, and actuate six tentacle-like soft bending actuators.

  4. A study on the force balance of an unbalanced globe valve

    International Nuclear Information System (INIS)

    Yang, Sang Min; Cho, Taik Dong; Ko, Sung Ho; Lee, Ho Young

    2007-01-01

    A pneumatic control valve is a piping element that controls the volumetric flow rate and pressure of a fluid: it is necessary to analyze the characteristics of the forces with respect to the opening of the valve in order to evaluate its operating performance. The forces occurring during operation are: resisting force and actuator force, where the load resistance is mostly affected by the fluid pressure difference of the valve. In this study, a force balance equation derived from the equilibrium relationship between the resisting force and the actuator force of an unbalanced globe valve is proposed, and the force balance equations are used to model the dynamic equations of a pneumatic unbalanced globe valve installed in nuclear power plants. A CFD analysis is also carried out to evaluate the pressure distribution and forces acting on the top and bottom planes of the valve plug. The results of this analysis have been verified through experimentation. This study has shown that the fluid pressure difference between the inlet and outlet of the valve, measured from the force balance equation of an unbalanced valve, should actually be examined with the fluid-pressure difference between the top and bottom side of the valve plug

  5. Soft Pneumatic Actuators for Rehabilitation

    Directory of Open Access Journals (Sweden)

    Guido Belforte

    2014-05-01

    Full Text Available Pneumatic artificial muscles are pneumatic devices with practical and various applications as common actuators. They, as human muscles, work in agonistic-antagonistic way, giving a traction force only when supplied by compressed air. The state of the art of soft pneumatic actuators is here analyzed: different models of pneumatic muscles are considered and evolution lines are presented. Then, the use of Pneumatic Muscles (PAM in rehabilitation apparatus is described and the general characteristics required in different applications are considered, analyzing the use of proper soft actuators with various technical properties. Therefore, research activity carried out in the Department of Mechanical and Aerospace Engineering in the field of soft and textile actuators is presented here. In particular, pneumatic textile muscles useful for active suits design are described. These components are made of a tubular structure, with an inner layer of latex coated with a deformable outer fabric sewn along the edge. In order to increase pneumatic muscles forces and contractions Braided Pneumatic Muscles are studied. In this paper, new prototypes are presented, based on a fabric construction and various kinds of geometry. Pressure-force-deformation tests results are carried out and analyzed. These actuators are useful for rehabilitation applications. In order to reproduce the whole upper limb movements, new kind of soft actuators are studied, based on the same principle of planar membranes deformation. As an example, the bellows muscle model and worm muscle model are developed and described. In both cases, wide deformations are expected. Another issue for soft actuators is the pressure therapy. Some textile sleeve prototypes developed for massage therapy on patients suffering of lymph edema are analyzed. Different types of fabric and assembly techniques have been tested. In general, these Pressure Soft Actuators are useful for upper/lower limbs treatments

  6. 3D Printed Multimaterial Microfluidic Valve.

    Directory of Open Access Journals (Sweden)

    Steven J Keating

    Full Text Available We present a novel 3D printed multimaterial microfluidic proportional valve. The microfluidic valve is a fundamental primitive that enables the development of programmable, automated devices for controlling fluids in a precise manner. We discuss valve characterization results, as well as exploratory design variations in channel width, membrane thickness, and membrane stiffness. Compared to previous single material 3D printed valves that are stiff, these printed valves constrain fluidic deformation spatially, through combinations of stiff and flexible materials, to enable intricate geometries in an actuated, functionally graded device. Research presented marks a shift towards 3D printing multi-property programmable fluidic devices in a single step, in which integrated multimaterial valves can be used to control complex fluidic reactions for a variety of applications, including DNA assembly and analysis, continuous sampling and sensing, and soft robotics.

  7. Piezoelectric valve

    Science.gov (United States)

    Petrenko, Serhiy Fedorovich

    2013-01-15

    A motorized valve has a housing having an inlet and an outlet to be connected to a pipeline, a saddle connected with the housing, a turn plug having a rod, the turn plug cooperating with the saddle, and a drive for turning the valve body and formed as a piezoelectric drive, the piezoelectric drive including a piezoelectric generator of radially directed standing acoustic waves, which is connected with the housing and is connectable with a pulse current source, and a rotor operatively connected with the piezoelectric generator and kinematically connected with the rod of the turn plug so as to turn the turn plug when the rotor is actuated by the piezoelectric generator.

  8. Performance of Grouted Splice Sleeve Connector under Tensile Load

    Directory of Open Access Journals (Sweden)

    A. Alias

    2016-05-01

    Full Text Available The grouted splice sleeve connector system takes advantage of the bond-slip resistance of the grout and the mechanical gripping of reinforcement bars to provide resistance to tensile force. In this system, grout acts as a load-transferring medium and bonding material between the bars and sleeve. This study adopted the end-to-end rebars connection method to investigate the effect of development length and sleeve diameter on the bonding performance of the sleeve connector. The end-to-end method refers to the condition where reinforcement bars are inserted into the sleeve from both ends and meet at the centre before grout is filled. Eight specimens of grouted splice sleeve connector were tested under tensile load to determine their performance. The sleeve connector was designed using 5 mm thick circular hollow section (CHS steel pipe and consisted of one external and two internal sleeves. The tensile test results show that connectors with a smaller external and internal sleeve diameter appear to provide better bonding performance. Three types of failure were observed in this research, which are bar fracture (outside the sleeve, bar pullout, and internal sleeve pullout. With reference to these failure types, the development length of 200 mm is the optimum value due to its bar fracture type, which indicates that the tensile capacity of the connector is higher than the reinforcement bar. It is found that the performance of the grouted splice sleeve connector is influenced by the development length of the reinforcement bar and the diameter of the sleeve.

  9. Downhole water management and robotic valve manipulation on electric wireline

    Energy Technology Data Exchange (ETDEWEB)

    Schwanitz, Brian [Welltec, Alleroed (Denmark); Petersen, Erik; Farias, Eduardo [Welltec do Brasil Ltda., Rio de Janeiro, RJ (Brazil)

    2008-07-01

    Due to high operating cost and challenging environments, the oil and gas industry is facing an increasing demand to identify areas where new intervention solutions can be applied. Down hole water management and robotic valve manipulation are some of the areas where new approaches are finding critical success. A new technology has enabled increased recovery rates by managing produced water and allowing remote mechanical manipulation of down hole valves on wireline. These services are possible when applying a robotic stroking device and a wireline key tool.This paper will examine the challenges and present case histories illustrating how advanced technological solutions were applied to overcome operational problem in order to enhance reservoir performance and well productivity. Specifically the paper will illustrate both how isolating sliding side door and setting bridge plug in high x-flow using wireline stroker and tractor technologies water cut were reduced from 85% to 5% and from 90% to 45% respectively and shifting isolation sleeve and open and close sliding sleeve replacing conventional methods with a solution that runs on electrical wireline meant a revolution within the oil and gas industry. (author)

  10. Improvements in nuclear fuel assembly sleeves

    International Nuclear Information System (INIS)

    Eaton, C.W.; Seeley, T.A.; Ince, G.; Speakman, W.T.

    1986-01-01

    The graphite sleeve of a nuclear fuel assembly or reflector element for a stringer mounts a number of grids via mounting assemblies installed in grooves formed in the interior wall surface of the sleeve. The bore of the sleeve is of reduced cross-section between two successive grooves such that the internal diameter of the sleeve is substantially the same as the inner diameter of the radially innermost extremity of the mounting assemblies whereby the coolant pressure loss at each transition between the reduced diameter bore section and the mounting assemblies is reduced. Each mounting assembly may be of radially contractable split ring construction to permit its placement in the groove and may carry burnable poison material. (author)

  11. Improvements in nuclear fuel assembly sleeves

    Energy Technology Data Exchange (ETDEWEB)

    Eaton, C.W.; Seeley, T.A.; Ince, G.; Speakman, W.T.

    1986-02-26

    The graphite sleeve of a nuclear fuel assembly or reflector element for a stringer mounts a number of grids via mounting assemblies installed in grooves formed in the interior wall surface of the sleeve. The bore of the sleeve is of reduced cross-section between two successive grooves such that the internal diameter of the sleeve is substantially the same as the inner diameter of the radially innermost extremity of the mounting assemblies whereby the coolant pressure loss at each transition between the reduced diameter bore section and the mounting assemblies is reduced. Each mounting assembly may be of radially contractable split ring construction to permit its placement in the groove and may carry burnable poison material.

  12. ADAM®/SIPLUG®: An innovative valve monitoring system

    International Nuclear Information System (INIS)

    Muñoz, L.; Krell, M.

    2012-01-01

    Optimized maintenance strategies are a key aspect for safe and undisturbed plant operation. Innovative valve service solutions, e.g. valve diagnostics can support this in an efficient way. The ADAM®/SIPLUG® valve monitoring system allows full online monitoring of valves and actuators with automatic evaluation and assessment. Especially for safety-related and operation-related valves this provides valuable information on components condition to ensure proper function and contribute to optimization of maintenance strategies as well as effective maintenance performance. The new SIPLUG®-4 modules are the evolutionary solution for valve diagnosis at the Motor Control Center (MCC). As the SIPLUG®-4 can be installed directly in the MCC outgoing actuator power cable it allows an easy installation in existing switchgear cabinets. Measurement at MCC means also zero effort for performance of diagnostics reducing the number of on-site activities. This results in decrease of maintenance costs and dose rates for deployed personnel. The ADAM® evaluation software and database was developed in parallel with the hardware. It provides automatic analysis of the monitoring results using the limit values specified for the valves. The measured data can be transmitted via the power plant’s local area network to the ADAM® data server, if the SIPLUG® online hardware is installed. With the mobile solution, the data can be transmitted via serial or USB interface to a PC or notebook. With this solution all measurement information will be available immediately in the offices of plant engineers. Also, with SIPLUG® online all operations of valves can be automatically recorded. More than 25 years of experience in various plants worldwide show that the application of ADAM®/SIPLUG® valve diagnostics solution leads to increased plant safety and availability. Some of the references for ADAM®/SIPLUG® are Germany, Switzerland, Brazil, Spain and Eastern Europe. (author)

  13. Design and experimental study of a novel giant magnetostrictive actuator

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Guangming, E-mail: yy0youxia@163.com [Vehicle and Electrical Engineering Department, Ordnance Engineering College, Shijiazhuang, 050003 China (China); Zhang, Peilin; He, Zhongbo; Li, Dongwei; Huang, Yingjie [Vehicle and Electrical Engineering Department, Ordnance Engineering College, Shijiazhuang, 050003 China (China); Xie, Wenqiang [Cadre Rotational Training Brigade, Ordnance Engineering College, Shijiazhuang, 050003 China (China)

    2016-12-15

    Giant magnetostrictive actuator has been widely used in precise driving occasions for its excellent performance. However, in driving a switching valve, especially the ball-valve in an electronic controlled injector, the actuator can’t exhibit its good performance for limits in output displacement and responding speed. A novel giant magnetostrictive actuator, which can reach its maximum displacement for being exerted with no bias magnetic field, is designed in this paper. Simultaneously, elongating of the giant magetostrictive material is converted to shortening of the actuator's axial dimension with the help of an output rod in “T” type. Furthermore, to save responding time, the driving voltage with high opening voltage while low holding voltage is designed. Responding time and output displacement are studied experimentally with the help of a measuring system. From measured results, designed driving voltage can improve the responding speed of actuator displacement quite effectively. And, giant magnetostrictive actuator can output various steady-state displacements to reach more driving effects. - Highlights: • GMA with zero bias magnetic field can reach maximum displacement in one direction. • Driving wave with high opening voltage can promote GMA's responding speed. • Higher opening voltage is exerted, less rise time is reached. • Continuous displacements from 0 to maximum value can be achieved by GMA.

  14. Control of soft machines using actuators operated by a Braille display.

    Science.gov (United States)

    Mosadegh, Bobak; Mazzeo, Aaron D; Shepherd, Robert F; Morin, Stephen A; Gupta, Unmukt; Sani, Idin Zhalehdoust; Lai, David; Takayama, Shuichi; Whitesides, George M

    2014-01-07

    One strategy for actuating soft machines (e.g., tentacles, grippers, and simple walkers) uses pneumatic inflation of networks of small channels in an elastomeric material. Although the management of a few pneumatic inputs and valves to control pressurized gas is straightforward, the fabrication and operation of manifolds containing many (>50) independent valves is an unsolved problem. Complex pneumatic manifolds-often built for a single purpose-are not easily reconfigured to accommodate the specific inputs (i.e., multiplexing of many fluids, ranges of pressures, and changes in flow rates) required by pneumatic systems. This paper describes a pneumatic manifold comprising a computer-controlled Braille display and a micropneumatic device. The Braille display provides a compact array of 64 piezoelectric actuators that actively close and open elastomeric valves of a micropneumatic device to route pressurized gas within the manifold. The positioning and geometries of the valves and channels in the micropneumatic device dictate the functionality of the pneumatic manifold, and the use of multi-layer soft lithography permits the fabrication of networks in a wide range of configurations with many possible functions. Simply exchanging micropneumatic devices of different designs enables rapid reconfiguration of the pneumatic manifold. As a proof of principle, a pneumatic manifold controlled a soft machine containing 32 independent actuators to move a ball above a flat surface.

  15. 49 CFR Appendix A to Part 180 - Internal Self-closing Stop Valve Emergency Closure Test for Liquefied Compressed Gases

    Science.gov (United States)

    2010-10-01

    ... internal self-closing stop valve's lever, piston, or other valve indicator has moved to the closed position. 2. On pump-actuated pressure differential internal valves, the three-way toggle valve handle or its...

  16. Use of a valve operation test and evaluation system to enhance valve reliability

    International Nuclear Information System (INIS)

    Lowry, D.A.

    1990-01-01

    Power plant owners have emphasized the need for assuring safe, reliable operation of valves. While most valves must simply open or close, the mechanisms involved can be quite complex. Motor operated valves (MOVs) must be properly adjusted to assure operability. Individual operator components determine the performance of the entire MOV. Failure in MOVs could cripple or shut down a unit. Thus, a complete valve program consisting of design reviews, operational testing, and preventive and predictive maintenance activities will enhance an owner's confidence level that his valves win operate as expected. Liberty's Valve Operation Test and Evaluation System (VOTES) accurately measures stein thrust without intruding on valve operation. Since mounting a strain gage to a valve stem is a desirable but impractical way of obtaining precise stem thrust, Liberty developed a method to obtain identical data by placing a strain gage sensor on the valve yoke. VOTES provides information which effectively eliminates costly, unscheduled downtime. This paper presents the results of infield VOTES testing. The system's proven ability to identify and characterize actuator and valve performance is demonstrated. Specific topics of discussion include the ability of VOTES to ease a utility's IE Bulletin 8543 concerns and conclusively diagnose MOV components. Data from static and differential pressure testing are presented. Technical, operational, and financial advantages resulting from VOTES technology are explored in detail

  17. Hydraulic actuator for an electric circuit breaker

    Science.gov (United States)

    Imam, Imdad [Colonie, NY

    1983-01-01

    This actuator comprises a fluid motor having a piston, a breaker-opening space at one side of the piston, and a breaker-closing space at its opposite side. An accumulator freely communicates with the breaker-opening space for supplying pressurized fluid thereto during a circuit breaker opening operation. The breaker-opening space and the breaker-closing space are connected by an impeded flow passage. A pilot valve opens to allow the pressurized liquid in the breaker-closing space to flow to a back chamber of a normally closed main valve to cause the main valve to be opened during a circuit breaker opening operation to release the pressurized liquid from the breaker-closing space. An impeded passage affords communication between the back chamber and a sump located on the opposite side of the main valve from the back chamber. The pilot valve and impeded passage allow rapid opening of the main valve with pressurized liquid from the breaker closing side of the piston.

  18. Relief valve testing study

    International Nuclear Information System (INIS)

    BROMM, R.D.

    2001-01-01

    Reclosing pressure-actuated valves, commonly called relief valves, are designed to relieve system pressure once it reaches the set point of the valve. They generally operate either proportional to the differential between their set pressure and the system pressure (gradual lift) or by rapidly opening fully when the set pressure is reached (pop action). A pop action valve allows the maximum fluid flow through the valve when the set pressure is reached. A gradual lift valve allows fluid flow in proportion to how much the system pressure has exceeded the set pressure of the valve (in the case of pressure relief) or has decreased below the set pressure (vacuum relief). These valves are used to protect systems from over and under pressurization. They are used on boilers, pressure vessels, piping systems and vacuum systems to prevent catastrophic failures of these systems, which can happen if they are under or over pressurized beyond the material tolerances. The construction of these valves ranges from extreme precision of less than a psi tolerance and a very short lifetime to extremely robust construction such as those used on historic railroad steam engines that are designed operate many times a day without changing their set pressure when the engines are operating. Relief valves can be designed to be immune to the effects of back pressure or to be vulnerable to it. Which type of valve to use depends upon the design requirements of the system

  19. Explosive actuated valve

    International Nuclear Information System (INIS)

    Byrne, K.G.

    1983-01-01

    1. A device of the character described comprising the combination of a housing having an elongate bore and including a shoulder extending inwardly into said bore, a single elongate movable plunger disposed in said bore including an outwardly extending flange adjacent one end thereof overlying said shoulder, normally open conduit means having an inlet and an outlet perpendicularly piercing said housing intermediate said shoulder and said flange and including an intermediate portion intersecting and normally openly communicating with said bore at said shoulder, normally closed conduit means piercing said housing and intersecting said bore at a location spaced from said normally open conduit means, said elongate plunger including a shearing edge adjacent the other end thereof normally disposed intermediate both of said conduit means and overlying a portion of said normally closed conduit means, a deformable member carried by said plunger intermediate said flange and said shoulder and normally spaced from and overlying the intermediate portion of said normally open conduit means, and means on the housing communicating with the bore to retain an explosive actuator for moving said plunger to force the deformable member against the shoulder and extrude a portion of the deformable member out of said bore into portions of the normally open conduit means for plugging the same and to effect the opening of said normally closed conduit means by the plunger shearing edge substantially concomitantly with the plugging of the normally open conduit means

  20. Experimental Validation of Modelled Fluid Forces in Fast Switching Hydraulic On/Off Valves

    DEFF Research Database (Denmark)

    Nørgård, Christian; Bech, Michael Møller; Roemer, Daniel Beck

    2015-01-01

    A prototype of a fast switching valve for a digital hydraulic machine has been designed and manufactured. The valve is composed of an annular seat plunger connected with a moving coil actuator as the force producing element. The valve prototype is designed for flow rates of 600 l/min with less th...

  1. NRC Information Notice No. 92-67: Deficiency in design modifications to address failures of Hiller actuators upon a gradual loss of air pressure

    International Nuclear Information System (INIS)

    Rossi, C.E.

    1993-01-01

    On January 7, 1992, Carolina Power and Light Company (Shearon Harris Plant) components associated with the air supply to the actuators of the three main feedwater preheater bypass isolation valves were not qualified for a Q class application. Specifically, the failure of the air pump in the non-Q Class, non-seismic instrument air supply to the valve actuator accumulator could prevent pressure switches upstream of the air pump from detecting slow leakage in the Q Class, seismic portion of the actuator air lines. The pressure switches were installed to ensure valve closure by sending an automatic close signal if the instrument air system pressure (upstream of the actuator air pump) dropped to 66 psig as discussed in IN 82-25. The main feedwater preheater bypass isolation valves function as containment isolation valves upon receipt of a feedwater isolation signal. The function of the air pump is to raise the normal instrument air supply pressure from 70 to 100 psig to approximately 150 psig. If accumulator pressure drops from 150 psig to 122 psig, the main feedwater preheater bypass isolation valve may not close within 10 seconds. If pressure drops to a value as low as 20 psig, it may not be sufficient to close the main feedwater preheater bypass isolation valve and keep it closed against the maximum differential pressure across the valve seat. Upon discovery of this condition, Shearon Harris established a surveillance interval for verifying that the actuators' components were functioning properly and that the accumulators were fully pressurized. On January 12, 1992, non-Q components were replaced with suitable components and testing was completed satisfactorily

  2. Osmotic actuation for microfluidic components in point-of-care applications

    KAUST Repository

    Chen, Yu-Chih

    2013-01-01

    We present a novel design of micropumps and valves driven by osmotic force for point-of-care applications. Although there have been significant progresses in microfluidic components and control devices such as fluidic diodes, switches, resonators and digital-to-analog converters, the ultimate power source still depends on bulky off-chip components, which are expensive and cannot be easily miniaturized. For point-of-care applications, it is critical to integrate all the components in a compact size at low cost. In this work, we report two key active components actuated by osmotic mechanism for total integrated microfluidic system. For the proof of concept, we have demonstrated valve actuation, which can maintain stable ON/OFF switching operations under 125 kPa back pressure. We have also implemented an osmotic pump, which can pump a high flow rate over 30 μL/min for longer than 30 minutes. The experimental data demonstrates the possibility and potential of applying osmotic actuation in point-of-care disposable microfluidics. © 2013 IEEE.

  3. Characteristics of electrostatic gas micro-pump with integrated polyimide passive valves

    International Nuclear Information System (INIS)

    Han, Jeahyeong; Yeom, Junghoon; Mensing, Glennys; Flachsbart, Bruce; Shannon, Mark A

    2012-01-01

    We report on the fabrication and characterization of electrostatic gas micro-pumps integrated with polyimide check valves. Touch-mode capacitance actuation, enabled by a fixed silicon electrode and a metal/polyimide diaphragm, creates the suction and push-out of the ambient gas; the gas flow is rectified by the check valves located at the inlet and outlet of the pump. The fabricated pumps were tested with various actuation voltages at different frequencies and duty cycles; an emphasis was placed on investigating the effect of valve flow conductance on the gas pumping characteristics. The pump with higher valve conductance could increase the operating frequency of the pump and affect the pumping characteristics from a pulsating flow to a continuous flow, leading to a higher gas flow rate. This electrostatic pump has a flow control resolution of 1 µL min −1 ; it could generate a gas flow up to 106 µL min −1 . (paper)

  4. Analysis of fatigue reliability for high temperature and high pressure multi-stage decompression control valve

    Science.gov (United States)

    Yu, Long; Xu, Juanjuan; Zhang, Lifang; Xu, Xiaogang

    2018-03-01

    Based on stress-strength interference theory to establish the reliability mathematical model for high temperature and high pressure multi-stage decompression control valve (HMDCV), and introduced to the temperature correction coefficient for revising material fatigue limit at high temperature. Reliability of key dangerous components and fatigue sensitivity curve of each component are calculated and analyzed by the means, which are analyzed the fatigue life of control valve and combined with reliability theory of control valve model. The impact proportion of each component on the control valve system fatigue failure was obtained. The results is shown that temperature correction factor makes the theoretical calculations of reliability more accurate, prediction life expectancy of main pressure parts accords with the technical requirements, and valve body and the sleeve have obvious influence on control system reliability, the stress concentration in key part of control valve can be reduced in the design process by improving structure.

  5. Design of a Soft Robot with Multiple Motion Patterns Using Soft Pneumatic Actuators

    Science.gov (United States)

    Miao, Yu; Dong, Wei; Du, Zhijiang

    2017-11-01

    Soft robots are made of soft materials and have good flexibility and infinite degrees of freedom in theory. These properties enable soft robots to work in narrow space and adapt to external environment. In this paper, a 2-DOF soft pneumatic actuator is introduced, with two chambers symmetrically distributed on both sides and a jamming cylinder along the axis. Fibers are used to constrain the expansion of the soft actuator. Experiments are carried out to test the performance of the soft actuator, including bending and elongation characteristics. A soft robot is designed and fabricated by connecting four soft pneumatic actuators to a 3D-printed board. The soft robotic system is then established. The pneumatic circuit is built by pumps and solenoid valves. The control system is based on the control board Arduino Mega 2560. Relay modules are used to control valves and pressure sensors are used to measure pressure in the pneumatic circuit. Experiments are conducted to test the performance of the proposed soft robot.

  6. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2008-11-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  7. Air Muscle Actuated Low Cost Humanoid Hand

    Directory of Open Access Journals (Sweden)

    Peter Scarfe

    2006-06-01

    Full Text Available The control of humanoid robot hands has historically been expensive due to the cost of precision actuators. This paper presents the design and implementation of a low-cost air muscle actuated humanoid hand developed at Curtin University of Technology. This hand offers 10 individually controllable degrees of freedom ranging from the elbow to the fingers, with overall control handled through a computer GUI. The hand is actuated through 20 McKibben-style air muscles, each supplied by a pneumatic pressure-balancing valve that allows for proportional control to be achieved with simple and inexpensive components. The hand was successfully able to perform a number of human-equivalent tasks, such as grasping and relocating objects.

  8. Grid sleeve bulge tool

    International Nuclear Information System (INIS)

    Phillips, W.D.; Vaill, R.E.

    1980-01-01

    An improved grid sleeve bulge tool is designed for securing control rod guide tubes to sleeves brazed in a fuel assembly grid. The tool includes a cylinder having an outer diameter less than the internal diameter of the control rod guide tubes. The walls of the cylinder are cut in an axial direction along its length to provide several flexible tines or ligaments. These tines are similar to a fork except they are spaced in a circumferential direction. The end of each alternate tine is equipped with a semispherical projection which extends radially outwardly from the tine surface. A ram or plunger of generally cylindrical configuration and about the same length as the cylinder is designed to fit in and move axially of the cylinder and thereby force the tined projections outwardly when the ram is pulled into the cylinder. The ram surface includes axially extending grooves and plane surfaces which are complimentary to the inner surfaces formed on the tines on the cylinder. As the cylinder is inserted into a control rod guide tube, and the projections on the cylinder placed in a position just below or above a grid strap, the ram is pulled into the cylinder, thus moving the tines and the projections thereon outwardly into contact with the sleeve, to plastically deform both the sleeve and the control rod guide tube, and thereby form four bulges which extend outwardly from the sleeve surface and beyond the outer periphery of the grid peripheral strap. This process is then repeated at the points above the grid to also provide for outwardly projecting surfaces, the result being that the grid is accurately positioned on and mechanically secured to the control rod guide tubes which extend the length of a fuel assembly

  9. Experience with control valve cavitation problems and their solutions

    International Nuclear Information System (INIS)

    Ozol, J.

    1988-01-01

    Pressure reduction in control valves can induce cavitation, which has three effects on the control valve. Firstly, it modifies or changes the hydraulic performance of the control valve. Since control valves are designed for noncavitating conditions, the result is usually reduced stability of the control valve or, in extreme cavitating conditions known as supercavitation, the valve may limit the flow rate and thus be undersized. Secondly, cavitation can cause material damage to valve parts, trim, or valve body, or erodes downstream piping; consequently, the valve or piping leaks. Thirdly, cavitation causes noise and vibration, which may cause major damage or destruction to equipment such as valve positioners, actuators, pipe supports and sometimes to other downstream valves. The purpose of this paper is twofold: (1) It describes the I.S.A. valve sizing equations and how they relate to cavitation. (2) It describes experiences with these three problems, and discusses corrective actions and practical approaches to their solution. This paper discusses thirteen cavitation experiences

  10. Part-turn gearboxes for electric actuators; Schwenkgetriebe fuer elektrische Stellantriebe

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, M. [Riester (W.) GmbH und Co. KG, Muellheim (Germany)

    2002-09-01

    Different types of gearboxes provide a useful complement to the electric actuator type ranges. The gearboxes can be combined with the actuators in many ways. Multi-turn actuators, for example, can be turned into part-turn actuators. When using a modular system, a suitable solution for almost any automation task in the field of industrial valves can be found. (orig.) [German] Sinnvoll ergaenzt werden elektrische Stellantriebe fuer Armaturen durch verschiedene Arten von Getrieben. Die Getriebe sind in vielfaeltiger Weise mit den Stellantrieben kombinierbar. So werden beispielsweise aus Drehantrieben Schwenkantriebe. Mit einem Baukasten-System laesst sich so fuer nahezu jede Automatisierungsaufgabe im Bereich der Industriearmaturen eine passende Loesung finden. (orig.)

  11. Steam relief valve control system for a nuclear reactor

    International Nuclear Information System (INIS)

    Torres, J.M.

    1976-01-01

    Described is a turbine follow system and method for Pressurized Water Reactors utilizing load bypass and/or atmospheric dump valves to provide a substitute load upon load rejection by bypassing excess steam to a condenser and/or to the atmosphere. The system generates a variable pressure setpoint as a function of load and applies an error signal to modulate the load bypass valves. The same signal which operates the bypass valves actuates a control rod automatic withdrawal prevent to insure against reactor overpower

  12. The use of valves in the SAGD process

    Energy Technology Data Exchange (ETDEWEB)

    Romano, Michael A. [Global Marketing, Oil and Gas, Tyco Valves and Controls (United States)

    2011-07-01

    Steam-assisted gravity drainage (SAGD) is a developing technology, the aim of which is to increase production of bitumen while minimizing its environmental footprint. Valves must meet the process conditions of the operations, which depend on weel depth: deeper reservoirs of bitumen require higher steam injection pressure. A wide range of valves is used throughout the SAGD process. In the water softening plant, butterfly and process lined valves are used. HP gate valves are used for isolation, globe valves for vents/drains/bypasses, along with ARC valves for steam and booster pump projection with steam traps on injection lines in steam injection. Isolation valves are used throughout the low pressure process including ball, gate and triple-offset valves. Pressure management is carried out on all pressure vessels and lines. Control and choke valves are installed on well pads and production. Instrumentation, actuation and controls are installed throughout. In the ideal situation, suppliers and process engineers would work together in the early stages of a project.

  13. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    Science.gov (United States)

    Jeon, Juncheol; Han, Chulhee; Chung, Jye Ung; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains.

  14. Performance evaluation of a piezoactuator-based single-stage valve system subjected to high temperature

    International Nuclear Information System (INIS)

    Jeon, Juncheol; Han, Chulhee; Ung Chung, Jye; Choi, Seung-Bok

    2015-01-01

    In this paper, a novel single-stage valve system activated by a piezostack actuator is proposed and experimentally evaluated at both room temperature (20 °C) and high temperature (100 °C) conditions. A hinge-lever displacement amplifier is adopted in the valve system to magnify the displacement generated from the piezostack actuator. After explaining the operating principle of the proposed piezostack-driven single-stage valve system, the geometric dimensions and mechanical properties of the valve components are discussed in details. An experimental apparatus is then manufactured to evaluate the performances of the valve system such as flow rate. The experimental apparatus consists of a heat chamber, which can regulate the temperature of the valve system and oil, pneumatic-hydraulic cylinders, a hydraulic circuit, a pneumatic circuit, electronic devices, an interface card, and a high voltage amplifier. The pneumatic-hydraulic cylinder transforms the pneumatic pressure into hydraulic pressure. The performances of the valve system regarding spool response, pressure drop, and flow rate are evaluated and presented. In addition, the performance of the valve system under high temperature condition is compared with that under room temperature condition. The experimental results are plotted in both frequency and time domains. (paper)

  15. Pump having pistons and valves made of electroactive actuators

    Science.gov (United States)

    Bar-Cohen, Yoseph (Inventor)

    1997-01-01

    The present invention provides a pump for inducing a displacement of a fluid from a first medium to a second medium, including a conduit coupled to the first and second media, a transducing material piston defining a pump chamber in the conduit and being transversely displaceable for increasing a volume of the chamber to extract the fluid from the first medium to the chamber and for decreasing the chamber volume to force the fluid from the chamber to the second medium, a first transducing material valve mounted in the conduit between the piston and the first medium and being transversely displaceable from a closed position to an open position to admit the fluid to the chamber, and control means for changing a first field applied to the piston to displace the piston for changing the chamber volume and for changing a second field applied to the first valve to change the position of the first valve.

  16. Parametric study for design of thermal sleeves

    International Nuclear Information System (INIS)

    Mukherjee, A.B.; Mehra, V.K.

    1985-01-01

    Thermal sleeves are used inside nozzle in many reactor components. Basic aim in design of thermal sleeve is to arrive at a set of dimensions for gap and annulus length, which will give rise to minimum thermal gradient in the base metal of the associated nozzle. Study includes the minimisation of the thermal gradient in the crotch zone by suitable choice of gap and annulus length. Three different geometries of nozzle radii 50.00 mm., 100 mm. and 200.0 mm. are studied for single and two concentric thermal sleeves model. The paper also presents effect of parameters like velocity of flow, temperature of fluid, materials etc. on the design of thermal sleeves. (orig.)

  17. Control of an air pressure actuated disposable bioreactor for cultivating heart valves

    NARCIS (Netherlands)

    Beelen, M.J.; Neerincx, P.E.; Molengraft, van de M.J.G.

    2011-01-01

    A disposable injection molded bioreactor for growing tissue-engineered heart valves is controlled to mimic the physiological heart cycle. Tissue-engineered heart valves, cultured from human stem cells, are a possible alternative for replacing failing aortic heart valves, where nowadays biological

  18. Math Machines: Using Actuators in Physics Classes

    Science.gov (United States)

    Thomas, Frederick J.; Chaney, Robert A.; Gruesbeck, Marta

    2018-01-01

    Probeware (sensors combined with data-analysis software) is a well-established part of physics education. In engineering and technology, sensors are frequently paired with actuators--motors, heaters, buzzers, valves, color displays, medical dosing systems, and other devices that are activated by electrical signals to produce intentional physical…

  19. The TaSST: Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, G.; Darriba Frederiks, A.; van Dijk, B.; Heylen, D.; Kröse, B.

    2013-01-01

    In this paper we outline the design process of the TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touch over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  20. The TaSST: Tactile sleeve for social touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; van Dijk, Elisabeth M.A.G.; Heylen, Dirk K.J.; Krose, Ben

    In this paper we outline the design process of the TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touch over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  1. The TaSST - Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; Van Dijk, Betsy; Heylen, Dirk

    2013-01-01

    In this paper we outline the design process of TaSST (Tactile Sleeve for Social Touch), a touch-sensitive vibrotactile arm sleeve. The TaSST was designed to enable two people to communicate different types of touches over a distance. The touch-sensitive surface of the sleeve consists of a grid of

  2. Numerical simulation on flow field of nuclear safety grade 2 single-seat pneumatic diaphragm control valve

    International Nuclear Information System (INIS)

    Zhong Yun; Zhang Jige; Wang Dezhong; Shi Jianzhong

    2010-01-01

    The Computational Fluid Dynamics (CFD) method is employed to simulate numerically the steady flow and transient flow under variable openings of the nuclear safety grade 2 single-seat pneumatic diaphragm control valve, which is a sleeve valve. The steady simulations under rated condition tells that there is a large amount of vortex in the valve seat necking and around the valve cone, which leads to a much greater flow impact on the head of the valve cone and uneven pressure distribution on spool face. More consideration should be taken on the characteristics of the valve cone accordingly, when designing a valve of this kind. Then the transient flow under 100% and 40% openings is simulated numerically on the basis of steady simulations. The pulsation of the pressure magnitude at the points with large vorticity, in the valve seat necking and around the valve cone, is monitored. The main pulsation frequencies differ from the low natural frequencies of the model, which means that it is safe from leading to structural resonance. (authors)

  3. Diagnostic for two-mode variable valve activation device

    Science.gov (United States)

    Fedewa, Andrew M

    2014-01-07

    A method is provided for diagnosing a multi-mode valve train device which selectively provides high lift and low lift to a combustion valve of an internal combustion engine having a camshaft phaser actuated by an electric motor. The method includes applying a variable electric current to the electric motor to achieve a desired camshaft phaser operational mode and commanding the multi-mode valve train device to a desired valve train device operational mode selected from a high lift mode and a low lift mode. The method also includes monitoring the variable electric current and calculating a first characteristic of the parameter. The method also includes comparing the calculated first characteristic against a predetermined value of the first characteristic measured when the multi-mode valve train device is known to be in the desired valve train device operational mode.

  4. Development of a hybrid safety system: Actuation of the secondary automatic depressurization system at an early stage

    International Nuclear Information System (INIS)

    Nishimoto, Masae; Umezawa, Shigemitsu; Okabe, Kazuharu; Matsuoka, Tsuyoshi

    1996-01-01

    A Hybrid Safety System, which is an optimum combination of active and passive safety systems, has been developed in order to improve the safety, reliability and economic features of the next generation of PWRs. The passive safety systems include Automatic primary Depressurization System (ADS), Secondary Automatic Depressurization System (SADS), advanced accumulators, gravity injection system and so on. In this study the authors have improved the actuation logic of the passive safety systems. The original logic in the previous study actuates ADS at an early stage of an event such as a Loss-of-Coolant Accident (LOCA), and this is followed by the actuation of SADS. In this study they divide SADS into two systems. The first, small SADS, uses small valves corresponding to the relief valves of the conventional PWR plants. The second, large SADS, corresponds to the original SADS using multiple valves of large capacity. With the new logic, the passive systems are actuated during a typical small LOCA. Small LOCA analyses using several break areas were performed for a 1,400 MWe PWR plant with a Hybrid Safety System. The results predict that core uncovery does not occur in the case of a relatively small break area and that core heat removal during a small LOCA is improved in comparison with the analyses for conventional PWR plants, where the secondary pressure remains higher during the event. The results also predict that this new logic make it possible to reduce the ADS valve size and the actuation pressure setpoint of the passive safety systems

  5. Compressed gas domestic aerosol valve design using high viscous product

    Directory of Open Access Journals (Sweden)

    A Nourian

    2016-10-01

    Full Text Available Most of the current universal consumer aerosol products using high viscous product such as cooking oil, antiperspirants, hair removal cream are primarily used LPG (Liquefied Petroleum Gas propellant which is unfriendly environmental. The advantages of the new innovative technology described in this paper are: i. No butane or other liquefied hydrocarbon gas is used as a propellant and it replaced with Compressed air, nitrogen or other safe gas propellant. ii. Customer acceptable spray quality and consistency during can lifetime iii. Conventional cans and filling technology There is only a feasible energy source which is inert gas (i.e. compressed air to replace VOCs (Volatile Organic Compounds and greenhouse gases, which must be avoided, to improve atomisation by generating gas bubbles and turbulence inside the atomiser insert and the actuator. This research concentrates on using "bubbly flow" in the valve stem, with injection of compressed gas into the passing flow, thus also generating turbulence. The new valve designed in this investigation using inert gases has advantageous over conventional valve with butane propellant using high viscous product (> 400 Cp because, when the valving arrangement is fully open, there are negligible energy losses as fluid passes through the valve from the interior of the container to the actuator insert. The use of valving arrangement thus permits all pressure drops to be controlled, resulting in improved control of atomising efficiency and flow rate, whereas in conventional valves a significant pressure drops occurs through the valve which has a complex effect on the corresponding spray.

  6. Hydraulic System Design of Hydraulic Actuators for Large Butterfly Valves

    Directory of Open Access Journals (Sweden)

    Ye HUANG

    2014-09-01

    Full Text Available Hydraulic control systems of butterfly valves are presently valve-controlled and pump-controlled. Valve-controlled hydraulic systems have serious power loss and generate much heat during throttling. Pump-controlled hydraulic systems have no overflow or throttling losses but are limited in the speed adjustment of the variable-displacement pump, generate much noise, pollute the environment, and have motor power that does not match load requirements, resulting in low efficiency under light loads and wearing of the variable-displacement pump. To overcome these shortcomings, this article designs a closed hydraulic control system in which an AC servo motor drives a quantitative pump that controls a spiral swinging hydraulic cylinder, and analyzes and calculates the structure and parameters of a spiral swinging hydraulic cylinder. The hydraulic system adjusts the servo motor’s speed according to the requirements of the control system, and the motor power matches the power provided to components, thus eliminating the throttling loss of hydraulic circuits. The system is compact, produces a large output force, provides stable transmission, has a quick response, and is suitable as a hydraulic control system of a large butterfly valve.

  7. Active combustion flow modulation valve

    Science.gov (United States)

    Hensel, John Peter; Black, Nathaniel; Thorton, Jimmy Dean; Vipperman, Jeffrey Stuart; Lambeth, David N; Clark, William W

    2013-09-24

    A flow modulation valve has a slidably translating hollow armature with at least one energizable coil wound around and fixably attached to the hollow armature. The energizable coil or coils are influenced by at least one permanent magnet surrounding the hollow armature and supported by an outer casing. Lorentz forces on the energizable coils which are translated to the hollow armature, increase or decrease the flow area to provide flow throttling action. The extent of hollow armature translation depends on the value of current supplied and the direction of translation depends on the direction of current flow. The compact nature of the flow modulation valve combined with the high forces afforded by the actuator design provide a flow modulation valve which is highly responsive to high-rate input control signals.

  8. Intra-thoracic Sleeve Migration (ITSM): an Underreported Phenomenon After Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Saber, Alan A; Shoar, Saeed; Khoursheed, Mousa

    2017-08-01

    Despite its technical simplicity, laparoscopic sleeve gastrectomy (LSG) complications are increasingly reported. Intra-thoracic sleeve migration (ITSM ) is a rare complication after LSG which has been inconsistently addressed in the literature. The purpose of this study was to emphasize ITSM occurrence after LSG and evaluate the perioperative factors associated with its development. Between January and July 2016, LSG patients diagnosed with ITSM at two bariatric surgery departments were identified. Perioperative factors were assessed for all the patients and compared between two groups, LSG alone and LSG with concomitant hiatal hernia (HH) repair (HHR). A total of 19 patients (6 males and 13 females) were included. Central obesity was present in 18 patients (94.7%). Nine patients (47.4%) had concomitant hiatal hernia repair during their original LSG. Post-LSG GERD (94.7%) (38.9% de novo and 61.1% recurrent) and post-LSG constipation (57.9%) were commonly associated with ITSM. Severe refractory GERD was the most common presentation for ITSM (94.7%), followed by epigastric pain (47.4%), persistent nausea/vomiting (36.8%), and dysphagia (21.1%). Time interval between primary LSG and ITSM diagnosis ranged from 1 day to 3 years. Patients with LSG and concomitant HHR presented with higher post-LSG BMI compared to the LSG patients (37 ± 6.4 kg/m 2 vs. 30.1 ± 6.3 kg/m 2 , p = 0.03). All the patients underwent successful reduction of ITSM and subsequent HHR. Central obesity, chronic constipation, post-LSG GERD, and concomitant HHR are commonly seen in post-laparoscopic sleeve gastrectomy intra-thoracic sleeve migration.

  9. High Temperature, High Frequency Fuel Metering Valve, Phase I

    Data.gov (United States)

    National Aeronautics and Space Administration — Active Signal Technologies and its subcontractor Moog propose to develop a high-frequency actuator driven valve intended to achieve TRL 6 by the end of Phase II....

  10. Design Optimization of Moving Magnet Actuated Valves for Digital Displacement Machines

    DEFF Research Database (Denmark)

    Madsen, Esben Lundø; Jørgensen, Janus Martin Thastum; Nørgård, Christian

    2017-01-01

    High-efficiency hydraulic machines using digital valves are presently a topic of great focus. Digital valve performance with respect to pressure loss, closing time as well as electrical power consumption, is key to obtaining high efficiency. A recent digital seat valve design developed at Aalborg...... optimized design closes in 2.1 ms, has a pressure drop of 0.8 bar at 150 l/min and yields a digital displacement machine average chamber efficiency of 98.9%. The design is simple in construction and uses a single coil, positioned outside the pressure chamber, eliminating the need for an electrical interface...

  11. Nuclear reactor steam depressurization valve

    International Nuclear Information System (INIS)

    Moore, G.L.

    1991-01-01

    This patent describes improvement in a nuclear reactor plant, an improved steam depressurization valve positioned intermediate along a steam discharge pipe for controlling the venting of steam pressure from the reactor through the pipe. The improvement comprises: a housing including a domed cover forming a chamber and having a partition plate dividing the chamber into a fluid pressure activation compartment and a steam flow control compartment, the valve housing being provided with an inlet connection and an outlet connection in the steam flow control compartment, and a fluid duct in communication with a source of fluid pressure for operating the valve; a valve set mounted within the fluid flow control compartment comprising a cylindrical section surrounding the inlet connection with one end adjoining the connection and having a radially projecting flange at the other end with a contoured extended valve sealing flange provided with an annular valve sealing member, and a valve cylinder traversing the partition plate and reciprocally movable within an opening in the partition plate with one terminal and extending into the fluid pressure activation compartment and the other terminal end extending into the steam flow control compartment coaxially aligned with the valve seat surrounding the inlet connection, the valve cylinder being surrounded by two bellow fluid seals and provided with guides to inhibit lateral movement, an end of the valve cylinder extending into the fluid flow control compartment having a radially projecting flange substantially conterminous with the valve seat flange and having a contoured surface facing and complimentary to the contoured valve seating surface whereby the two contoured valve surfaces can meet in matching relationship, thus providing a pressure actuated reciprocatable valve member for making closing contact with the valve seat and withdrawing therefrom for opening fluid flow through the valve

  12. Shuttle Primary Reaction Control Subsystem Thruster Fuel Valve Pilot Seal Extrusion: A Failure Correlation

    Science.gov (United States)

    Waller, Jess; Saulsberry, Regor L.

    2003-01-01

    Pilot operated valves (POVs) are used to control the flow of hypergolic propellants monomethylhydrazine (fuel) and nitrogen tetroxide (oxidizer) to the Shuttle orbiter Primary Reaction Control Subsystem (PRCS) thrusters. The POV incorporates a two-stage design: a solenoid-actuated pilot stage, which in turn controls a pressure-actuated main stage. Isolation of propellant supply from the thruster chamber is accomplished in part by a captive polytetrafluoroethylene (PTFE) pilot seal retained inside a Custom 455.1 stainless steel cavity. Extrusion of the pilot seal restricts the flow of fuel around the pilot poppet, thus impeding or preventing the main valve stage from opening. It can also prevent the main stage from staying open with adequate force margin, particularly if there is gas in the main stage actuation cavity. During thruster operation on-orbit, fuel valve pilot seal extrusion is commonly indicated by low or erratic chamber pressure or failure of the thruster to fire upon command (Fail-Off). During ground turnaround, pilot seal extrusion is commonly indicated by slow gaseous nitrogen (GN2) main valve opening times (greater than 38 ms) or slow water main valve opening response times (greater than 33 ms). Poppet lift tests and visual inspection can also detect pilot seal extrusion during ground servicing; however, direct metrology on the pilot seat assembly provides the most quantitative and accurate means of identifying extrusion. Minimizing PRCS fuel valve pilot seal extrusion has become an important issue in the effort to improve PRCS reliability and reduce associated life cycle costs.

  13. Design method for marine direct drive volume control ahead actuator

    Directory of Open Access Journals (Sweden)

    WANG Haiyang

    2018-02-01

    Full Text Available [Objectives] In order to reduce the size, weight and auxiliary system configuration of marine ahead actuators, this paper proposes a kind of direct drive volume control electro-hydraulic servo ahead actuator. [Methods] The protruding and indenting control of the servo oil cylinder are realized through the forward and reverse of the bidirectional working gear pump, and the flow matching valve implements the self-locking of the ahead actuator in the target position. The mathematical model of the ahead actuator is established, and an integral separation fuzzy PID controller designed. On this basis, using AMESim software to build a simulation model of the ahead actuator, and combined with testing, this paper completes an analysis of the control strategy research and dynamic and static performance of the ahead actuator. [Results] The experimental results agree well with the simulation results and verify the feasibility of the ahead actuator's design. [Conclusions] The research results of this paper can provide valuable references for the integration and miniaturization design of marine ahead actuators.

  14. All carbon coaxial supercapacitors based on hollow carbon nanotube sleeve structure

    International Nuclear Information System (INIS)

    Zang, Xiaobei; Xu, Ruiqiao; Zhang, Yangyang; Zhang, Li; Wei, Jinquan; Wang, Kunlin; Zhu, Hongwei; Li, Xinming

    2015-01-01

    All carbon coaxial supercapacitors based on hollow carbon nanotube (CNT) sleeve structure are assembled and tested. The key advantage of the structure is that the inner core electrode is variable from CNT sleeve sponges, to CNT fibers, reduced graphene oxide fibers, and graphene woven fabrics. By changing core electrodes from sleeve sponges to CNT fibers, the electrochemical performance has been significantly enhanced. The capacitance based on sleeve sponge + CNT fiber double the capacitances of double-sleeve sponge supercapacitors thanks to reduction of the series and internal resistances. Besides, the coaxial sleeve structure possesses many other features, including high rate capacitance, long cycle life, and good flexibility. (paper)

  15. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    NARCIS (Netherlands)

    Groen, Maarten; Wu, Kai; Brookhuis, Robert Anton; van Houwelingen, Marc J.; Brouwer, Dannis Michel; Lötters, Joost Conrad; Wiegerink, Remco J.

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve.

  16. Valving for controlling a fluid-driven reciprocating apparatus

    Science.gov (United States)

    Whitehead, John C.

    1995-01-01

    A pair of control valve assemblies for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve assembly is switched by a pressure signal depending on the state of its counterpart's piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. Each of the valve assemblies uses an intake-exhaust valve and a signal valve with the signal valve of one pump being connected to be pressure responsive to the piston of the opposite cylinder or pump.

  17. Fast force actuators for LSST primary/tertiary mirror

    Science.gov (United States)

    Hileman, Edward; Warner, Michael; Wiecha, Oliver

    2010-07-01

    The very short slew times and resulting high inertial loads imposed upon the Large Synoptic Survey Telescope (LSST) create new challenges to the primary mirror support actuators. Traditionally large borosilicate mirrors are supported by pneumatic systems, which is also the case for the LSST. These force based actuators bear the weight of the mirror and provide active figure correction, but do not define the mirror position. A set of six locating actuators (hardpoints) arranged in a hexapod fashion serve to locate the mirror. The stringent dynamic requirements demand that the force actuators must be able to counteract in real time for dynamic forces on the hardpoints during slewing to prevent excessive hardpoint loads. The support actuators must also maintain the prescribed forces accurately during tracking to maintain acceptable mirror figure. To meet these requirements, candidate pneumatic cylinders incorporating force feedback control and high speed servo valves are being tested using custom instrumentation with automatic data recording. Comparative charts are produced showing details of friction, hysteresis cycles, operating bandwidth, and temperature dependency. Extremely low power actuator controllers are being developed to avoid heat dissipation in critical portions of the mirror and also to allow for increased control capabilities at the actuator level, thus improving safety, performance, and the flexibility of the support system.

  18. Motor operated valves problems tests and simulations

    Energy Technology Data Exchange (ETDEWEB)

    Pinier, D.; Haas, J.L.

    1996-12-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a {open_quotes}boiler{close_quotes} effect: determination of the necessary modifications: development and testing of anti-boiler effect systems.

  19. Motor operated valves problems tests and simulations

    International Nuclear Information System (INIS)

    Pinier, D.; Haas, J.L.

    1996-01-01

    An analysis of the two refusals of operation of the EAS recirculation shutoff valves enabled two distinct problems to be identified on the motorized valves: the calculation methods for the operating torques of valves in use in the power plants are not conservative enough, which results in the misadjustement of the torque limiters installed on their motorizations, the second problem concerns the pressure locking phenomenon: a number of valves may entrap a pressure exceeding the in-line pressure between the disks, which may cause a jamming of the valve. EDF has made the following approach to settle the first problem: determination of the friction coefficients and the efficiency of the valve and its actuator through general and specific tests and models, definition of a new calculation method. In order to solve the second problem, EDF has made the following operations: identification of the valves whose technology enables the pressure to be entrapped: the tests and numerical simulations carried out in the Research and Development Division confirm the possibility of a open-quotes boilerclose quotes effect: determination of the necessary modifications: development and testing of anti-boiler effect systems

  20. Extending service life of steam generators by sleeving tubes

    International Nuclear Information System (INIS)

    Gutzwiller, J.E.

    1982-01-01

    Steam generator tubes that are failing due to IGA in the tubesheet crevice can be kept in service by using the basic sealable sleeve design developed by BandW. Variations of the present sleeve design could significantly reduce the number of tubes that must be plugged each year. Sleeving had the potential of keeping 28 percent more tubes in service during 1979. Lowering the overall rate at which tubes are removed from service by plugging will reduce the probability of having to derate the plant or replace the steam generator. Considering tomorrow's replacement power costs, sleeving to keep tubes in service is a practical and sound investment

  1. Recommendations for main line block valves installation in gas pipelines; Recomendacoes para instalacao de valvulas de bloqueio de linha tronco em gasodutos

    Energy Technology Data Exchange (ETDEWEB)

    Frisoli, Caetano [TRANSPETRO - PETROBRAS Transportes, Rio de Janeiro, RJ (Brazil); Oliveira, Valeriano Duque de [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2003-07-01

    Cases of gas pipelines block valves and its pneumatic actuators presenting problems during the final pipeline commissioning and pre-operation phases, like internal leaks, leaking to the atmosphere, pneumatic circuit defects caused by water and debris, are nearly common. The majority can be avoided if a series of measuring are to be planned and implemented, as well as if an adequate planning of commissioning operations and line gasification, valves and actuators, are to be applied. This paper shows the practical experience in the construction and commissioning of valves and its actuators in the Bolivia-Brazil gas pipeline, which, in the first construction phase had a series of problems. After the diagnosis a set of procedures was implemented in the secondary construction phase, resulting in insignificant problems detected. All measures and procedures taken in the planning process, as well as additional aspects related to the main line valve design, its by-passes and supports, are demonstrated. (author)

  2. Electrical actuators in a Chilean copper mine; Elektrische Stellantriebe in chilenischem Kupferbergwerk

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, Michael [AUMA Riester GmbH und Co. KG, Muellheim (Germany)

    2008-03-15

    Mining of copper at the Los Pelambres mine in Chile yields a mixture of water, sand, sludge and mineral reminiscent of fresh concrete. This high-viscosity material is treated in a series of filters and sedimentation installations. The gate-type and other valves necessary for distribution are operated by the electrical actuator systems examined in this article. A special feature of this arrangement is the fact that the actuator itself is separated from the appurtenant local control system. Separate installation means that the actuator drive systems, which are mounted on mobile stands of 2 m height, can be easily parameterized. (orig.)

  3. High-authority smart material integrated electric actuator

    Science.gov (United States)

    Weisensel, G. N.; Pierce, Thomas D.; Zunkel, Gary

    1997-05-01

    For many current applications, hydraulic power is still the preferred method of gaining mechanical advantage. However, in many of these applications, this power comes with the penalties of high weight, size, cost, and maintenance due to the system's distributed nature and redundancy requirements. A high authority smart material Integrated Electric Actuator (IEA) is a modular, self-contained linear motion device that is capable of producing dynamic output strokes similar to those of hydraulic actuators yet at significantly reduced weight and volume. It provides system simplification and miniaturization. This actuator concept has many innovative features, including a TERFENOL-D-based pump, TERFENOL-D- based active valves, control algorithms, a displacement amplification unit and integrated, unitized packaging. The IEA needs only electrical power and a control command signal as inputs to provide high authority, high response rate actuation. This approach is directly compatible with distributed control strategies. Aircraft control, automotive brakes and fuel injection, and fluid power delivery are just some examples of the IEA's pervasive applications in aerospace, defense and commercial systems.

  4. ToF-SIMS Characterization of Biocompatible Silk/Polypyrrole Electromechanical Actuators

    Science.gov (United States)

    Bradshaw, Nathan; Severt, Sean; Wang, Zhaoying; Klemke, Carly; Larson, Jesse; Zhu, Zihua; Murphy, Amanda; Leger, Janelle

    2015-03-01

    Materials capable of controlled movements that can also interface with biological environments are highly sought after for biomedical devices such as valves, blood vessel sutures, cochlear implants and controlled drug release devices. Recently we have reported the synthesis of films composed of a conductive interpenetrating network of the biopolymer silk fibroin and poly(pyrrole). These silk-PPy composites function as bilayer electromechanical actuators in a biologically-relevant environment, can be actuated repeatedly, and are able to generate forces comparable with natural muscle (>0.1 MPa), making them an ideal candidate for interfacing with biological tissues. Here, time of flight secondary ion mass spectrometry was used to investigate the migration of ions in the devices during actuation. These findings will be discussed in the context of the actuation mechanism and opportunities for further improvements in device stability and performance.

  5. Timing tests: automatic valve closure for tritium leaks

    International Nuclear Information System (INIS)

    Hanel, S.

    1976-01-01

    How fast can an automotive valve be closed after a tritium leak occurs in a system. Tests described found that a valve can be closed within fifteen seconds of leakage. In one practical example considered, this delay would limit loss of tritium from a plumbing leak in a tritium system to 1 1 / 4 g. The tests were made in a typical LLL air-flush hood in which a tritium handling system had been installed. Incidental observations suggest that further study be made of a possible leak-actuated recovery system for an entire tritium facility

  6. Empirical modeling of dynamic behaviors of pneumatic artificial muscle actuators.

    Science.gov (United States)

    Wickramatunge, Kanchana Crishan; Leephakpreeda, Thananchai

    2013-11-01

    Pneumatic Artificial Muscle (PAM) actuators yield muscle-like mechanical actuation with high force to weight ratio, soft and flexible structure, and adaptable compliance for rehabilitation and prosthetic appliances to the disabled as well as humanoid robots or machines. The present study is to develop empirical models of the PAM actuators, that is, a PAM coupled with pneumatic control valves, in order to describe their dynamic behaviors for practical control design and usage. Empirical modeling is an efficient approach to computer-based modeling with observations of real behaviors. Different characteristics of dynamic behaviors of each PAM actuator are due not only to the structures of the PAM actuators themselves, but also to the variations of their material properties in manufacturing processes. To overcome the difficulties, the proposed empirical models are experimentally derived from real physical behaviors of the PAM actuators, which are being implemented. In case studies, the simulated results with good agreement to experimental results, show that the proposed methodology can be applied to describe the dynamic behaviors of the real PAM actuators. Copyright © 2013 ISA. Published by Elsevier Ltd. All rights reserved.

  7. Evaluation of existing EPRI and INEL test data to determine the worm to worm gear coefficient of friction in Limitorque actuators

    Energy Technology Data Exchange (ETDEWEB)

    Garza, I.A.

    1996-12-01

    About the last sizing parameter for motor operated valves which has not been determined by utility or NRC sponsored testing is actuator efficiency. A by-product of EPRI testing for valve factors is the measurement of the actuator efficiencies. Motor sizing in this testing provides efficiency testing for motors running near synchronous speed. INEL testing, sponsored by the NRC, for stem factors and rate of loading provides complimentary data for motors loaded down to zero speed. This paper analyzes the data from these two test programs to determine the coefficient of friction for the worm to worm gear interface. This allowed the development of an algorithm for determining the efficiency of actuators which have not been tested. This paper compares the results of this algorithm to the test data to provide a measure of the accuracy of this method for calculating actuator efficiency.

  8. Evaluation of existing EPRI and INEL test data to determine the worm to worm gear coefficient of friction in Limitorque actuators

    International Nuclear Information System (INIS)

    Garza, I.A.

    1996-01-01

    About the last sizing parameter for motor operated valves which has not been determined by utility or NRC sponsored testing is actuator efficiency. A by-product of EPRI testing for valve factors is the measurement of the actuator efficiencies. Motor sizing in this testing provides efficiency testing for motors running near synchronous speed. INEL testing, sponsored by the NRC, for stem factors and rate of loading provides complimentary data for motors loaded down to zero speed. This paper analyzes the data from these two test programs to determine the coefficient of friction for the worm to worm gear interface. This allowed the development of an algorithm for determining the efficiency of actuators which have not been tested. This paper compares the results of this algorithm to the test data to provide a measure of the accuracy of this method for calculating actuator efficiency

  9. A Solar Energy Powered Autonomous Wireless Actuator Node for Irrigation Systems

    OpenAIRE

    Lajara, Rafael; Alberola, Jorge; Pelegr?-Sebasti?, Jos?

    2010-01-01

    The design of a fully autonomous and wireless actuator node ("wEcoValve mote") based on the IEEE 802.15.4 standard is presented. The system allows remote control (open/close) of a 3-lead magnetic latch solenoid, commonly used in drip irrigation systems in applications such as agricultural areas, greenhouses, gardens, etc. The very low power consumption of the system in conjunction with the low power consumption of the valve, only when switching positions, allows the system to be solar powered...

  10. Robust Control of a Hydraulically Actuated Manipulator Using Sliding Mode Control

    DEFF Research Database (Denmark)

    Hansen, Michael Rygaard; Andersen, Torben Ole; Pedersen, Henrik Clemmensen

    2005-01-01

    This paper presents an approach to robust control called sliding mode control (SMC) applied to the a hydraulic servo system (HSS), consisting of a servo valve controlled symmetrical cylinder. The motivation for applying sliding mode control to hydraulically actuated systems is its robustness...

  11. Valve packing manual. A maintenance application guide

    International Nuclear Information System (INIS)

    Aikin, J.A.; McCutcheon, R.G.; Cumming, D.

    1997-01-01

    Since 1970, AECL Chalk River Mechanical Equipment Development (MED) branch has invested over 175 person years in testing related to improving valve packing performance. Successful developments, including, 'live-loading', reduced packing heights, and performance-based packing qualification testing have been implemented. Since 1986, MED and the Integrated Valve Actuator Program Task Force - Valve Packing Steering Committee (IVAP-VPSC) have been involved in the development of combination die-formed graphite packing for use in CANDU plants. Many reports, articles, and specifications have been issued. Due to the large amount of test data and reports, a more user-friendly document has been prepared for everyday use. The Valve Packing Manual is based on many years of MED research and testing, as well as operating experience from CANDU nuclear generating stations (NGS). Since 1986, packing research and testing has been funded by the CANDU Owners Group (COG), the Electric Power Research Institute (EPRI), and participating valve packing manufacturers. The Valve Packing Manual (VPM) provides topical summaries of all work related to valve packing done since 1985. It includes advances in configuration design, stem packing friction, materials specifications, and installation procedures. This paper provides an overview on the application of the VPM with a focus on qualification testing, packing configuration, and stem packing friction. (author)

  12. Characterization and Surgical Management of Achilles Tendon Sleeve Avulsions.

    Science.gov (United States)

    Huh, Jeannie; Easley, Mark E; Nunley, James A

    2016-06-01

    An Achilles sleeve avulsion occurs when the tendon ruptures distally from its calcaneal insertion as a continuous "sleeve." This relatively rare injury pattern may not be appreciated until the time of surgery and can be challenging to treat because, unlike a midsubstance rupture, insufficient tendon remains on the calcaneus to allow for end-to-end repair, and unlike a tuberosity avulsion fracture, any bony element avulsed with the tendon is inadequate for internal fixation. This study aimed to highlight the characteristics of Achilles sleeve avulsions and present the outcomes of operative repair using suture anchor fixation. A retrospective analysis was conducted on 11 consecutive Achilles tendon sleeve avulsions (10 males, 1 female; mean age 44 years) that underwent operative repair between 2008 and 2014. Patient demographics, injury presentation, and operative details were reviewed. Postoperative outcomes were collected at a mean follow-up of 38.4 (range, 12-83.5) months, including the American Orthopaedic Foot & Ankle Society (AOFAS) Ankle-Hindfoot score, visual analog scale (VAS) for pain, plantarflexion strength, patient satisfaction, and complications. Eight patients (72.7%) had preexisting symptoms of insertional Achilles disease. Ten of 11 (90.9%) injuries were sustained during recreational athletic activity. An Achilles sleeve avulsion was recognized preoperatively in 7 of 11 (64%) cases, where lateral ankle radiographs demonstrated a small radiodensity several centimeters proximal to the calcaneal insertion. Intraoperatively, 90.9% of sleeve avulsions had a concomitant Haglund deformity and macroscopic evidence of insertional tendinopathy. All patients healed after suture anchor repair. The average AOFAS score was 92.8 and VAS score was 0.9. Ten patients (90.9%) were completely satisfied. One complication occurred, consisting of delayed wound healing. Achilles tendon sleeve avulsions predominantly occurred in middle-aged men with preexisting insertional

  13. Pressure Control of a Pneumatic Actuator Using On/O Solenoid Valves

    OpenAIRE

    Jeddi Tehrani, Maisam

    2008-01-01

    Nowadays a very important aspect in heavy duty vehicles is the braking system. The braking system can be divided into EBS brakes, exhaust brake and retarder, where the latter is of interest in the present Master's Thesis. This thesis presents an investigation whether it is possible to substitute today's concept, i.e. controlling the air pressure to the retarder using a proportional-valve, with two so-called on/o®-valves and a pressure sensor, which will reduce expenses and contingently hyster...

  14. Modeling and testing of a knitted-sleeve fluidic artificial muscle

    Science.gov (United States)

    Ball, Erick J.; Meller, Michael A.; Chipka, Jordan B.; Garcia, Ephrahim

    2016-11-01

    The knitted-sleeve fluidic muscle is similar in design to a traditional McKibben muscle, with a separate bladder and sleeve. However, in place of a braided sleeve, it uses a tubular-knit sleeve made from a thin strand of flexible but inextensible yarn. When the bladder is pressurized, the sleeve expands by letting the loops of fiber slide past each other, changing the dimensions of the rectangular cells in the stitch pattern. Ideally, the internal volume of the sleeve would reach a maximum when its length has contracted by 2/3 from its maximum length, and although this is not reachable in practice, preliminary tests show that free contraction greater than 50% is achievable. The motion relies on using a fiber with a low coefficient of friction in order to reduce hysteresis to an acceptable level. In addition to increased stroke length, potential advantages of this technique include slower force drop-off during the stroke, more useable energy in certain applications, and greater similarity to the force-length relationship of skeletal muscle. Its main limitation is its potentially greater effect from friction compared to other fluidic muscle designs.

  15. Motor operated valve testing and the 'rate of loading' phenomenon

    International Nuclear Information System (INIS)

    Black, B.R.

    1991-01-01

    This paper discusses valve design features which affect the ability to predict motor operated valve (MOV) performance and reviews factors which should be considered when selecting switch settings to limit stem loads. Considerable attention is given to the rate of loading phenomenon which affects the relationship between valve stem thrust and actuator spring pack deflection. Equations are developed, and testing is discussed which permit the construction of an MOV dynamic model. Factors which must be considered when maintaining switch settings correct throughout the life of the plant are discussed. And switch setting acceptance criteria for use with baseline Static and Design Basis testing are suggested

  16. Application of Model Based Prognostics to Pneumatic Valves in a Cryogenic Propellant Loading Testbed

    Data.gov (United States)

    National Aeronautics and Space Administration — Pneumatic-actuated valves are critical components in many applications, including cryogenic propellant loading for space operations. For these components, failures...

  17. Analysis of Dielectric Electro Active Polymer Actuator and its High Voltage Driving Circuits

    DEFF Research Database (Denmark)

    Thummala, Prasanth; Huang, Lina; Zhang, Zhe

    2012-01-01

    Actuators based on dielectric elastomers have promising applications in artificial muscles, space robotics, mechatronics, micro-air vehicles, pneumatic and electric automation technology, heating valves, loud speakers, tissue engineering, surgical tools, wind turbine flaps, toys, rotary motors...

  18. Leakage characterization of a piloted power operated relief valve

    International Nuclear Information System (INIS)

    Ezekoye, L.I.; Hess, M.D.

    1995-01-01

    In Westinghouse Pressurized Water Reactors (PWRs), power operated relief valves (PORVs) are used to provide overpressure protection of the Pressurizer. The valves are fail closed globe valves which means that power is required to open the valves and, on loss of power, the valves close. There are two ways to operate the PORVs. The more common way is to directly couple the disc to an actuator via a disc-stem assembly. The type of design is not the object of this paper. The other and less common way of operating a PORV is by piloting the main valve such that the opening or closing of a pilot valve opens and closes the main valve. This is the design of interest. In most plants, the PORVs are installed with a water loop seal while in some plants no water loop seals are used. It is generally accepted that loop seal installation minimizes valve seat leakage. In non-loop seal installation, the valve seat is exposed to steam which increases the potential for seat leakage. This paper describes the results of some tests performed with nitrogen and steam to characterize the leakage potential of a pilot operated PORV. The test results were compared with seat leakage tests of check valves to provide insight on the leakage testing of pilot operated valves and check valves. The paper also compares the test data with leakage estimates using the ASME/ANSI OM Code guidance on valve leakage

  19. Research design and improvement of high temperature high pressure solenoid valve

    International Nuclear Information System (INIS)

    Luo Yongtang

    1987-12-01

    A process for development of the pilot type high temperature high pressure solenoid valve used in a PWR power plant is described. The whole development process might be divided into two phases: research design and improvement. In the former phase the questions had chiefly been approached in the following several aspects: the principle construction design, the determination of values for the constructionally key elements, the valve seal design and the solenoid actuator design, and made such valve's successful design in the main. In the latter phase an improvement had been made upon such valve against the problems during the testing use of the valve for a period of time, i.e. the unsatisfactory leak tightness, and achieved satisfactory results. The consummate success in this development not only has met the needs of the engineering project, but also made us obtain a valuable experience useful to design the similar valves

  20. Butterfly valve torque prediction methodology

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Sharma, V.; Kalsi, M.S.; Wolfe, K.

    1994-01-01

    As part of the Motor-Operated Valve (MOV) Performance Prediction Program, the Electric Power Research Institute has sponsored the development of methodologies for predicting thrust and torque requirements of gate, globe, and butterfly MOVs. This paper presents the methodology that will be used by utilities to calculate the dynamic torque requirements for butterfly valves. The total dynamic torque at any disc position is the sum of the hydrodynamic torque, bearing torque (which is induced by the hydrodynamic force), as well as other small torque components (such as packing torque). The hydrodynamic torque on the valve disc, caused by the fluid flow through the valve, depends on the disc angle, flow velocity, upstream flow disturbances, disc shape, and the disc aspect ratio. The butterfly valve model provides sets of nondimensional flow and torque coefficients that can be used to predict flow rate and hydrodynamic torque throughout the disc stroke and to calculate the required actuation torque and the maximum transmitted torque throughout the opening and closing stroke. The scope of the model includes symmetric and nonsymmetric discs of different shapes and aspects ratios in compressible and incompressible fluid applications under both choked and nonchoked flow conditions. The model features were validated against test data from a comprehensive flowloop and in situ test program. These tests were designed to systematically address the effect of the following parameters on the required torque: valve size, disc shapes and disc aspect ratios, upstream elbow orientation and its proximity, and flow conditions. The applicability of the nondimensional coefficients to valves of different sizes was validated by performing tests on 42-in. valve and a precisely scaled 6-in. model. The butterfly valve model torque predictions were found to bound test data from the flow-loop and in situ testing, as shown in the examples provided in this paper

  1. Highly-Integrated Hydraulic Smart Actuators and Smart Manifolds for High-Bandwidth Force Control

    Directory of Open Access Journals (Sweden)

    Victor Barasuol

    2018-06-01

    Full Text Available Hydraulic actuation is the most widely used alternative to electric motors for legged robots and manipulators. It is often selected for its high power density, robustness and high-bandwidth control performance that allows the implementation of force/impedance control. Force control is crucial for robots that are in contact with the environment, since it enables the implementation of active impedance and whole body control that can lead to a better performance in known and unknown environments. This paper presents the hydraulic Integrated Smart Actuator (ISA developed by Moog in collaboration with IIT, as well as smart manifolds for rotary hydraulic actuators. The ISA consists of an additive-manufactured body containing a hydraulic cylinder, servo valve, pressure/position/load/temperature sensing, overload protection and electronics for control and communication. The ISA v2 and ISA v5 have been specifically designed to fit into the legs of IIT’s hydraulic quadruped robots HyQ and HyQ-REAL, respectively. The key features of these components tackle 3 of today’s main challenges of hydraulic actuation for legged robots through: (1 built-in controllers running inside integrated electronics for high-performance control, (2 low-leakage servo valves for reduced energy losses, and (3 compactness thanks to metal additive manufacturing. The main contributions of this paper are the derivation of the representative dynamic models of these highly integrated hydraulic servo actuators, a control architecture that allows for high-bandwidth force control and their experimental validation with application-specific trajectories and tests. We believe that this is the first work that presents additive-manufactured, highly integrated hydraulic smart actuators for robotics.

  2. Water hammer caused by closure of turbine safety spherical valves

    Science.gov (United States)

    Karadžić, U.; Bergant, A.; Vukoslavčević, P.

    2010-08-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perućica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  3. Water hammer caused by closure of turbine safety spherical valves

    International Nuclear Information System (INIS)

    Karadzic, U; Vukoslavcevic, P; Bergant, A

    2010-01-01

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  4. Water hammer caused by closure of turbine safety spherical valves

    Energy Technology Data Exchange (ETDEWEB)

    Karadzic, U; Vukoslavcevic, P [Faculty of Mechanical Engineering, University of Montenegro Dzordza Vasingtona nn, Podgorica, 81000 (Montenegro); Bergant, A, E-mail: uros.karadzic@ac.m [LitostrojPower d.o.o., Litostrojska 50, Ljubljana, 1000 (Slovenia)

    2010-08-15

    This paper investigates water hammer effects caused by closure of spherical valves against the discharge. During the first phase of modernisation of Perucica high-head hydropower plant (HPP), Montenegro, safety spherical valves (inlet turbine valves) have been refurbished on the first two Pelton turbine units. The valve closure is controlled by the valve actuator (hydraulic servomotor). Because the torque acting on the valve body is dependent on flow conditions the valve closing time may vary significantly for different flow velocities (passive valve). For the passive valve the torques acting on the valve body should be considered in the valve model. The valve closing time results from numerical simulation. On the contrary, for the active valve the valve closing time is assumed prior to simulation. The spherical valve boundary condition is incorporated into the method of characteristics (MOC) algorithm. The staggered (diamond) grid in applying the MOC is used in this paper. The passive valve boundary condition is described by the water hammer equations, the valve equation that relates discharge to pressure head drop and the dynamic equation of the valve body motion (torque equation). The active valve boundary condition is described by the first two equations, respectively. Standard quasi-steady friction model is used for estimating friction losses in plant's tunnel and penstocks. Numerical results using both the active and the passive spherical valve models are compared with results of measurements. It has been found that the influence of flow conditions on the spherical valve closing time is minor for the cases considered. Computed and measured results agree reasonably well.

  5. Light-Triggered Soft Artificial Muscles: Molecular-Level Amplification of Actuation Control Signals.

    Science.gov (United States)

    Dicker, Michael P M; Baker, Anna B; Iredale, Robert J; Naficy, Sina; Bond, Ian P; Faul, Charl F J; Rossiter, Jonathan M; Spinks, Geoffrey M; Weaver, Paul M

    2017-08-23

    The principle of control signal amplification is found in all actuation systems, from engineered devices through to the operation of biological muscles. However, current engineering approaches require the use of hard and bulky external switches or valves, incompatible with both the properties of emerging soft artificial muscle technology and those of the bioinspired robotic systems they enable. To address this deficiency a biomimetic molecular-level approach is developed that employs light, with its excellent spatial and temporal control properties, to actuate soft, pH-responsive hydrogel artificial muscles. Although this actuation is triggered by light, it is largely powered by the resulting excitation and runaway chemical reaction of a light-sensitive acid autocatalytic solution in which the actuator is immersed. This process produces actuation strains of up to 45% and a three-fold chemical amplification of the controlling light-trigger, realising a new strategy for the creation of highly functional soft actuating systems.

  6. Switching sliding mode force tracking control of piezoelectric-hydraulic pump-based friction element actuation systems for automotive transmissions

    Science.gov (United States)

    Kim, Gi-Woo; Wang, K. W.

    2009-08-01

    In this study, a nonlinear sliding-mode controller is designed for force tracking of a piezoelectric-hydraulic pump (PHP)-based actuation system, which is developed to replace the current electro-hydraulic actuation systems for automatic transmission (AT) friction elements, such as band brakes or clutches. By utilizing the PHP, one can eliminate the various hydraulic components (oil pump, regulating valve and control valve) in current ATs and achieve a simpler configuration with more efficient operation. With the derived governing equation of motion of the PHP-based actuation system integrated with the friction element (band brake), a switching control law is synthesized based on the sliding-mode theory. To evaluate the effectiveness of the proposed control law, its force tracking performance for the engagement of a friction element during an AT 1\\to 2 up-shift is examined experimentally. It is shown that one can successfully track the desired force trajectory for AT shift control with small tracking error. This study demonstrates the potential of the PHP as a new controllable actuation system for AT friction elements.

  7. Switching sliding mode force tracking control of piezoelectric-hydraulic pump-based friction element actuation systems for automotive transmissions

    International Nuclear Information System (INIS)

    Kim, Gi-Woo; Wang, K W

    2009-01-01

    In this study, a nonlinear sliding-mode controller is designed for force tracking of a piezoelectric-hydraulic pump (PHP)-based actuation system, which is developed to replace the current electro-hydraulic actuation systems for automatic transmission (AT) friction elements, such as band brakes or clutches. By utilizing the PHP, one can eliminate the various hydraulic components (oil pump, regulating valve and control valve) in current ATs and achieve a simpler configuration with more efficient operation. With the derived governing equation of motion of the PHP-based actuation system integrated with the friction element (band brake), a switching control law is synthesized based on the sliding-mode theory. To evaluate the effectiveness of the proposed control law, its force tracking performance for the engagement of a friction element during an AT 1→2 up-shift is examined experimentally. It is shown that one can successfully track the desired force trajectory for AT shift control with small tracking error. This study demonstrates the potential of the PHP as a new controllable actuation system for AT friction elements

  8. PLUSS-A weldless leaktight sleeve for alloy 600/690 steam generator tubes

    International Nuclear Information System (INIS)

    Potz, F.; Bohmann, W.

    1998-01-01

    The ABB PLUSS sleeving represents a new SG tube repair technique qualified and approved to replace in the future most of the plugging as well as welded sleeving. Basically the advantages of an innovative combination of both alloys 600/690 and 800 are taken into consideration. The upper sleeve/SG tube-joint is hydraulically expanded stressing the SG tube only within the elastic range. The lower joint is hard rolled. The installation processes are simple and reproducible, fast, computerized and individually recorded. The operating temperature range of the sleeved SG-tube is effectively reduced so that any further corrosion is impeded. Both, sleeve and SG tube are fully inspectable by ECT. (author)

  9. Development of hydraulic brake actuator for active brake control; Active brake seigyoyo yuatsu booster no kaihatsu

    Energy Technology Data Exchange (ETDEWEB)

    Konishi, Y; Hattori, M. Sugisawa, M.; Nishii, M [Aisin Seiki Co. Ltd., Aichi (Japan)

    1997-10-01

    Recently, application of active brake control systems of the vehicle are increasing. (Vehicle stability control, Panic brake assist ) We have developed a new hydraulic brake actuator for active brake control systems. New hydraulic brake actuator is composed of the three parts. (Hydraulic booster unit, Power supply unit, Control valve unit) This report describes the construction of the new hydraulic booster unit. 2 refs., 10 figs.

  10. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    Science.gov (United States)

    Groen, Maarten S.; Wu, Kai; Brookhuis, Robert A.; van Houwelingen, Marc J.; Brouwer, Dannis M.; Lötters, Joost C.; Wiegerink, Remco J.

    2014-12-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch.

  11. A piezoelectric micro control valve with integrated capacitive sensing for ambulant blood pressure waveform monitoring

    International Nuclear Information System (INIS)

    Groen, Maarten S; Wu, Kai; Brookhuis, Robert A; Lötters, Joost C; Wiegerink, Remco J; Van Houwelingen, Marc J; Brouwer, Dannis M

    2014-01-01

    We have designed and characterized a MEMS microvalve with built-in capacitive displacement sensing and fitted it with a miniature piezoelectric actuator to achieve active valve control. The integrated displacement sensor enables high bandwidth proportional control of the gas flow through the valve. This is an essential requirement for non-invasive blood pressure waveform monitoring based on following the arterial pressure with a counter pressure. Using the capacitive sensor, we demonstrate negligible hysteresis in the valve control characteristics. Fabrication of the valve requires only two mask steps for deep reactive ion etching (DRIE) and one release etch. (paper)

  12. What matters after sleeve gastrectomy: patient characteristics or surgical technique?

    Science.gov (United States)

    Dhar, Vikrom K; Hanseman, Dennis J; Watkins, Brad M; Paquette, Ian M; Shah, Shimul A; Thompson, Jonathan R

    2018-03-01

    The impact of operative technique on outcomes in laparoscopic sleeve gastrectomy has been explored previously; however, the relative importance of patient characteristics remains unknown. Our aim was to characterize national variability in operative technique for laparoscopic sleeve gastrectomy and determine whether patient-specific factors are more critical to predicting outcomes. We queried the database of the Metabolic and Bariatric Surgery Accreditation and Quality Improvement Program for laparoscopic sleeve gastrostomies performed in 2015 (n = 88,845). Logistic regression models were used to determine predictors of postoperative outcomes. In 2015, >460 variations of laparoscopic sleeve gastrectomy were performed based on combinations of bougie size, distance from the pylorus, use of staple line reinforcement, and oversewing of the staple line. Despite such substantial variability, technique variants were not predictive of outcomes, including perioperative morbidity, leak, or bleeding (all P ≥ .05). Instead, preoperative patient characteristics were found to be more predictive of these outcomes after laparoscopic sleeve gastrectomy. Only history of gastroesophageal disease (odds ratio 1.44, 95% confidence interval 1.08-1.91, P < .01) was associated with leak. Considerable variability exists in technique among surgeons nationally, but patient characteristics are more predictive of adverse outcomes after laparoscopic sleeve gastrectomy. Bundled payments and reimbursement policies should account for patient-specific factors in addition to current accreditation and volume thresholds when deciding risk-adjustment strategies. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Improved design and durability of aluminum die casting horizontal shot sleeves

    Science.gov (United States)

    Birceanu, Sebastian

    The design and performance of shot sleeves is critical in meeting the engineering requirements of aluminum die cast parts. Improvement in shot sleeve materials have a major impact on dimensional stability, reproducibility and quality of the product. This investigation was undertaken in order to improve the life of aluminum die casting horizontal shot sleeves. Preliminary pin tests were run to evaluate the soldering, wash-out and thermal fatigue behavior of commercially available materials and coatings. An experimental rig was designed and constructed for shot sleeve configuration evaluation. Fabrication and testing of experimental shot sleeves was based upon preliminary results and manufacturing costs. Three shot sleeve designs and materials were compared to a reference nitrided H13 sleeve. Nitrided H13 is the preferred material for aluminum die casting shot sleeves because of wear resistance, strength and relative good soldering and wash-out resistance. The study was directed towards damage evaluation on the area under the pouring hole. This area is the most susceptible to damage because of high temperatures and impingement of molten aluminum. The results of this study showed that tungsten and molybdenum had the least amount of soldering and wash-out damage, and the best thermal fatigue resistance. Low solubility in molten aluminum and stability of intermetallic layers are main factors that determine the soldering and wash-out behavior. Thermal conductivity and thermal expansion coefficient directly influence thermal fatigue behavior. TiAlN nanolayered coating was chosen as the material with the best damage resistance among several commercial PVD coatings, because of relatively large thickness and simple deposition conditions. The results show that molybdenum thermal sprayed coating provided the best protection against damage under the pouring hole. Improved bonding is however required for life extension of the coating. TiAlN PVD coating applied on H13 nitrided

  14. Miniaturization of a Quasi-Servo Valve and Its Application to Positon Control of a Rubber Artificial Muscle with Built-in Sensor

    Directory of Open Access Journals (Sweden)

    Moriwake Yoshinori

    2016-01-01

    Full Text Available Nowadays, the care and welfare pneumatic devices to support a nursing care and a self-reliance of the elderly and the disabled are actively researched and developed by many researchers. These wearable devices require many actuators and control valves for multi degrees of freedom. The total weight and volume of the wearable devices increases according to the degree of freedom. Our final goal is to develop a compact wearable actuator with built-in sensor, controller and control valve and to apply it to a wearable assisted device. In our previous study, a small-sized quasi-servo valve which consists of two on/off control valves and an embedded controller was developed. In this study, the quasi-servo valve composing of much smaller-sized (40% in mass, 42% in volume on/off valves is proposed and tested. In addition, the rubber artificial muscle with an ultrasonic sensor as a built-in displacement sensor is proposed and a position control of the muscle is carried out using the tested tiny valve and built-in sensor. As a result, it was confirmed that the position control of the muscle can be realized using the tested ultrasonic sensor.

  15. Root cause analysis of SI line-seated thermal sleeve separation failures

    International Nuclear Information System (INIS)

    Jo, Jong Chull; Jhung, Myung Jo; Kim, Hho Jung

    2004-01-01

    At conventional pressurized water reactors, a thermal sleeve (named simply 'sleeve' hereafter) is seated inside the nozzle part of each Safety Injection (SI) branch pipe to prevent and relieve potential excessive transient thermal stress in the nozzle wall when a cold water is injected during the safety injection mode Recently, mechanical failures that the sleeves are separated from the SI branch pipe and fall into the connected cold leg main pipe were occurred in sequence at Yonggwang units 5 and 6 and Ulchin unit 5. There were many activities and efforts to figure out the causes of those failures with experts' reasoning, but the proposed causes were derived from superficial views rather than physically concrete grounds or analysis results. The prerequisites to find out the root causes of failure mechanism will be to identify the flow situation in the pipe junction area connecting the cold leg with the SI pipe and to know the vibration characteristics of sleeves. This paper investigates the flow field in the pipe junction thru a numerical simulation and vibration characteristics of thermal sleeves thru a modal analysis, from which the root causes of sleeve separation mechanism are analyzed

  16. Analysis of the giant magnetostrictive actuator with strong bias magnetic field

    Energy Technology Data Exchange (ETDEWEB)

    Xue, Guangming, E-mail: yy0youxia@163.com; He, Zhongbo; Li, Dongwei; Yang, Zhaoshu; Zhao, Zhenglong

    2015-11-15

    Giant magnetostrictive actuator with strong bias magnetic field is designed to control the injector bullet valve opening and closing. The relationship between actuator displacement amplitude and input signal direction is analyzed. And based on the approximate linearity of strain-magnetic field, second-order system model of the actuator displacement is established. Experimental system suitable for the actuator is designed. The experimental results show that, the square voltage amplitude being 12 V, the actuator displacement amplitude is about 17 μm with backward direction signal input while being 1.5 μm under forward direction signal. From the results, the suitable input direction is confirmed to be backward. With exciting frequncy lower than 200 Hz, the error between the model and experimental result is less than 1.7 μm. So the model is validated under the low-frequency signal input. The testing displacement-voltage curves are approximately straight lines. But due to the biased position, the line slope and the displacement-voltage linearity change as the input voltage changes. - Highlights: • Giant magnetostrictive actuator with strong bias magnetic field is designed. • The relationship between actuator displacement amplitude and input current direction is analyzed. • The model of the actuator displacement is established and its accuracy is verified by the test. • The actuator displacement-voltage curves are achieved by the test, and the curves’ characteristics are analyzed theoretically.

  17. Sleeve gastrectomy and gastro-oesophageal reflux disease: a complex relationship.

    Science.gov (United States)

    Mahawar, Kamal K; Jennings, Neil; Balupuri, Shlok; Small, Peter K

    2013-07-01

    Sleeve gastrectomy is rapidly becoming popular as a standalone bariatric operation. At the same time, there are valid concerns regarding its long-term durability and postoperative gastro-oesophageal reflux disease. Though gastric bypass remains the gold standard bariatric operation, it is not suitable for all patients. Sleeve gastrectomy is sometimes the only viable option. Patients with inflammatory bowel disease, liver cirrhosis, significant intra-abdominal adhesions involving small bowel and those reluctant to undergo gastric bypass could fall in this category. It is widely recognised that some patients report worsening of their gastro-oesophageal reflux disease after sleeve gastrectomy. Still, others develop de novo reflux. This review examines if it is possible to identify these patients prior to surgery and thus prevent postoperative gastro-oesophageal reflux disease after sleeve gastrectomy.

  18. Advancements in valve technology and industry lessons lead to improved plant reliability and cost savings

    International Nuclear Information System (INIS)

    Sharma, V.; Kalsi, M.S.

    2005-01-01

    Plant reliability and safety hinges on the proper functioning of several valves. Recent advancements in valve technology have resulted in new analytical and test methods for evaluating and improving valve and actuator reliability. This is especially significant in critical service applications in which the economic impact of a valve failure on production, outage schedules and consequential damages far surpasses the initial equipment purchase price. This paper presents an overview of recent advances in valve technology driven by reliability concerns and cost savings objectives without comprising safety in the Nuclear Power Industry. This overview is based on over 27 years of experience in supporting US and International nuclear power utilities, and contributing to EPRI, and NSSS Owners' Groups in developing generic models/methodologies to address industry wide issues; performing design basis reviews; and implementing plant-wide valve reliability improvement programs. Various analytical prediction software and hardware solutions and training seminars are now available to implement valve programs covering power plants' lifecycle from the construction phase through life extension and power up rate. These tools and methodologies can enhance valve-engineering activities including the selection, sizing, proper application, condition monitoring, failure analysis, and condition based maintenance optimization with a focus on potential bad actors. This paper offers two such examples, the Kalsi Valve and Actuator Program (KVAP) and Check Valve Analysis and Prioritization (CVAP) [1-3, 8, 9, 11-13]. The advanced, validated torque prediction models incorporated into KVAP software for AOVs and MOVs have improved reliability of margin predictions and enabled cost savings through elimination of unwarranted equipment modifications. CVAP models provides a basis to prioritize the population of valves recommended for preventive maintenance, inspection and/or modification, allowing

  19. Sleeve type repair of degraded nuclear steam generator tubes

    International Nuclear Information System (INIS)

    Ayres, P.S.; Stark, L.E.; Feldstein, J.G.; Fu, T.

    1986-01-01

    A sealable sleeve is described for insertion into the repair of a degraded tube which consists of: a hollow core inner member of the same material as the degraded tube; a thinner outer member of substantially pure nickel and resistant to corrosive attack, the outer member being metallurgically bonded with the inner member; an expanded portion of the sleeve at one end for positioning in the tube within a tube sheet; a multiplicity of grooves formed in and adjacent to the other end of the sleeve which extends into the free-standing portion of the tube beyond the tube sheet, and a noble metal braze material contained in the grooves

  20. Zipping dielectric elastomer actuators: characterization, design and modeling

    International Nuclear Information System (INIS)

    Maffli, L; Rosset, S; Shea, H R

    2013-01-01

    We report on miniature dielectric elastomer actuators (DEAs) operating in zipping mode with an analytical model that predicts their behavior. Electrostatic zipping is a well-known mechanism in silicon MEMS to obtain large deformations and forces at lower voltages than for parallel plate electrostatic actuation. We extend this concept to DEAs, which allows us to obtain much larger out-of-plane displacements compared to silicon thanks to the softness of the elastomer membrane. We study experimentally the effect of sidewall angles and elastomer prestretch on 2.3 mm diameter actuators with PDMS membranes. With 15° and 22.5° sidewall angles, the devices zip in a bistable manner down 300 μm to the bottom of the chambers. The highly tunable bistable behavior is controllable by both chamber geometry and membrane parameters. Other specific characteristics of zipping DEAs include well-controlled deflected shape, tunable displacement versus voltage characteristics to virtually any shape, including multi-stable modes, sealing of embedded holes or channels for valving action and the reduction of the operating voltage. These properties make zipping DEAs an excellent candidate for applications such as integrated microfluidics actuators or Braille displays. (paper)

  1. Self Touch to Touch Others: Designing the Tactile Sleeve for Social Touch

    NARCIS (Netherlands)

    Huisman, G.; Darriba Frederiks, A.; van Dijk, B.; Kröse, B.; Heylen, D.

    2013-01-01

    In this paper we present the concept and initial design stages of the TaSST (Tactile Sleeve for Social Touch). The TaSST consists of a soft pressure-sensitive input layer, and an output layer containing vibration motors. A touch to ones own sleeve is felt as a vibration on the sleeve of another

  2. Self touch to touch others : designing the tactile sleeve for social touch

    NARCIS (Netherlands)

    Huisman, Gijs; Darriba Frederiks, Aduén; Heylen, Dirk; Van Dijk, Betsy; Kröse, Ben

    2013-01-01

    In this paper we present the concept and initial design stages of the TaSST (Tactile Sleeve for Social Touch). The TaSST consists of a soft pressure-sensitive input layer, and an output layer containing vibration motors. A touch to ones own sleeve is felt as a vibration on the sleeve of another

  3. Preventive maintenance measures and repeat tests on actuators

    International Nuclear Information System (INIS)

    Hueren, H.

    1990-01-01

    At Biblis Nuclear Power Station, about 1500 electrical actuators and variable speed drives of various model ranges and with various driving end speeds and actuating times are installed and about 600 of these are located in important safety engineering systems. In order to optimize the preventive maintenance measures on the drives, a data bank has been established into which are stored, in addition to the fixed type data of each drive, inter alia, statements about location of application, valve type, inspection cycle, calendar year of next maintenance, findings during inspection measures and causes of faults. Before each unit inspection, in addition to the inspection lists, the maintenance and installation records and also the associated job instructions are produced from this data processing equipment. (orig.) [de

  4. The Otto-Atkinson engine. A study of fluid flow and combustion with early and late inlet valve closing

    Energy Technology Data Exchange (ETDEWEB)

    Haakansson, Henrik

    1999-10-01

    This report contains results of measurements on an Otto engine. The purpose for this work has been to do measurements of the flow in the cylinder but also measurements of the cylinder pressure have been performed. The flow measurements are made with the method Laser Doppler Velocimetry, LDV. The reason why these measurements are made at all are the pump losses that implies a lower efficiency for the Otto engine at part load. In this work two alternative ways that highly reduces the pump losses are examined. These are early inlet valve closing and late inlet valve closing. To further increase the efficiency at part load an increased compression ratio has been used together with the different valve strategies. With these two ways of operation, at a part load of about 4 - 5 IMEP{sub net}, increases of about 20% of the net indicated efficiency has been obtained. Additionally this report contains a chapter about the possible use of a variable valve actuation or timing system, VVA or VVT. Many conditions for the Otto cycle can be improved by the use of a variable valve actuation and in this chapter it is dealt with the most important ones.

  5. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention.

    Science.gov (United States)

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-12-21

    To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients.

  6. The Klinger hot gas double axial valve

    International Nuclear Information System (INIS)

    Kruschik, J.; Hiltgen, H.

    1984-01-01

    The Klinger hot gas valve is a medium controlled double axial valve with advanced design features and safety function. It was first proposed by Klinger early in 1976 for the PNP-Project as a containment shut-off for hot helium (918 deg. C and 42 bar), because a market research has shown that such a valve is not state of present techniques. In the first stage of development a feasibility study had to be made by detailed design, calculation and by basic experiments for key components in close collaboration with Interatom/GHT. This was the basis for further design, calculation, construction and experimental work for such a valve prototype within the new development contract. The stage of knowledge to that time revealed the following key priority development areas: Finite element stress analysis for the highly stressed high temperature main components; development of an insulation layout; Detailed experimental tests of functionally important structural components or units of the valve, partly at Klingers (gasstatic bearings, flexible metallic sealing element, aerodynamic and thermohydraulic tests), partly at Interatom (actuator unit and also gasstatic bearings), partly at HRB in Juelich (flexible metallic sealing system, aerodynamic and thermohydraulic tests); Design of a test valve for experimental work in the KVK (test circuit at Interatom) for evaluation of temperature distribution and reliability of operation; Design of a prototype and extensive testing in the KVK

  7. Seismic qualification of motor operated valves - alternate approach

    International Nuclear Information System (INIS)

    Bruck, P.M.; Eissa, M.A.

    1998-01-01

    This paper presents a potential alternate method for determining operating capacity of motor-operated valves subjected to seismic and other applicable loadings. As a result of programs at nuclear facilities to ensure the operational capability of MOVs (under NRC GL89-10), extensive analytical focus to develop the structural capability of valves has ensued. In the past, seismic qualification of valves typically addressed the strength of the topwork structure to resist inertial loading from excitation of the large valve actuator mass. These evaluations paid little or no consideration to the loading resulting from valve closing forces. The focus of the recent efforts is to develop the maximum operational capability of the valve, in terms of thrust, with consideration of seismic and other services loading as applicable. The alternate method outlined in this paper presents a series of thrust capacity curves, with reduction factors for seismic loading which can be applied and developed to determine safe thrust loadings without performing extensive analytical effort. A similar approach was put forward by the SQUG GIP approach to MOVs to ensure the safe operation of valves based on past earthquake experience. However, the GIP approach cannot be used to determine safe operational loads and thus has limited use in the necessary analysis required for GL89-10 programs at nuclear facilities. (orig.)

  8. Simulation of the behaviour of a servo actuated check valve upon rupture of the feedwater pipe

    International Nuclear Information System (INIS)

    Lucas, A.M. de; Perezagua, R.L.; Rosa, B. de la; Sanz, J.

    1995-01-01

    The steam generator replacement programme at Almaraz NPP, provides for the installation of a replacement damped non-return valve for the feedwater system. the function of this valve is to protect the steam generator in the event of a rupture in the feedwater pipe. Sudden closure of the check valve, against the flow and following rupture of the feedwater pipe, causes overpressure in the valve which is transmitted to the steam generator nozzle. It is therefore necessary to know this when designing the internal systems of the steam generator. Using the RELAP5/MODE3 code, it has been possible to simulate the dynamic behaviour of a check valve upon rupture of a feedwater pipe postulated outside the containment. The calculation model has been applied to different types of check valve. (Author)

  9. Parallel kinematic mechanisms for distributed actuation of future structures

    Science.gov (United States)

    Lai, G.; Plummer, A. R.; Cleaver, D. J.; Zhou, H.

    2016-09-01

    Future machines will require distributed actuation integrated with load-bearing structures, so that they are lighter, move faster, use less energy, and are more adaptable. Good examples are shape-changing aircraft wings which can adapt precisely to the ideal aerodynamic form for current flying conditions, and light but powerful robotic manipulators which can interact safely with human co-workers. A 'tensegrity structure' is a good candidate for this application due to its potentially excellent stiffness and strength-to-weight ratio and a multi-element structure into which actuators could be embedded. This paper presents results of an analysis of an example practical actuated tensegrity structure consisting of 3 ‘unit cells’. A numerical method is used to determine the stability of the structure with varying actuator length, showing how four actuators can be used to control movement in three degrees of freedom as well as simultaneously maintaining the structural pre-load. An experimental prototype has been built, in which 4 pneumatic artificial muscles (PAMs) are embedded in one unit cell. The PAMs are controlled antagonistically, by high speed switching of on-off valves, to achieve control of position and structure pre-load. Experimental and simulation results are presented, and future prospects for the approach are discussed.

  10. Stepper Motor Actuated Microvalve

    Energy Technology Data Exchange (ETDEWEB)

    Fazal, Imran; Louwerse, Marcus; Jansen, Henri; Elwenspoek, Miko [MESA Research Institute, University of Twente EWI/TST, P. off Box 217 Enschede (Netherlands)

    2006-04-01

    We present the design, fabrication and characterization of a novel microvalve realized by combining micro and fine machining techniques. The design is for high flow rates at high pressure difference between inlet and outlet, burst pressure of up to 15 bars, there is no power consumption required for the valve to maintain its position during operation in any intermediate state and the process gas does not interact with the actuation mechanism. The microvalve was experimentally characterized with airflows. It is shown that flow rates of 220 ml/min at a pressure difference of 4 bars could be achieved with the minimum accurate flow rate of 2-8 ml/min.

  11. Weight Loss after Sleeve Gastrectomy in Super Superobesity

    Directory of Open Access Journals (Sweden)

    J.-M. Catheline

    2012-01-01

    Full Text Available Objective. This prospective study evaluated laparoscopic sleeve gastrectomy for its safety and efficiency in excess weight loss (%EWL in super superobese patients (BMI >60 Kg/m2. Results. Thirty patients (33 women and 7 men were included, with mean age of 35 years (range 18 to 59. Mean preoperative BMI was 66 Kg/m2 (range 60 to 85. The study included one patient with complete situs inversus and 4 (14% with previous restrictive gastric banding. The mean operative time was 120 minutes (range 80 to 220 min and the mean hospital stay was 7.5 days (4 to 28 days. There was no postoperative mortality or need for a laparotomy conversion. Two subphrenic hematomas, one gastric fistula, and one pulmonary embolism, were the major complications. After 18 months 17 (77% had sufficient weight loss and six had insufficient results, leading to either re-sleeve gastrectomy (3, or gastric bypass (2. Three years after the initial laparoscopic sleeve gastrectomy, the mean EWL was 51% (range 21 to 82. Conclusion. The laparoscopic sleeve gastrectomy is a safe and efficient operating procedure for treating super superobesity. In the case of insufficient weight loss, a second-stage operation like resleeve gastrectomy or gastric bypass can be proposed.

  12. Study on Flow-Shifted Region Depending on Spool Displacement in Hydraulic Servo Valve with Hybrid Lap

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Hwanghun; Yun, Sonam; Lee, Sungsoo [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of); Yang, Jooho [Pukyong Nat' l Univ., Busan (Korea, Republic of)

    2013-03-15

    This study examined the static characteristics of a spool valve with a hybrid lap between the spool land and the sleeve. The static equation for the pressure characteristics was derived from flow equations that depend on the spool displacement, and the final model was derived from q{sub a}=q{sub b}=0 because the pressure characteristics test needs to block the control port in the valve. The static equation for the flow characteristics was derived from the pressure characteristics when the control port is open (q{sub a}=q{sub b}, p{sub a}=p{sub b}). The characteristic equation in the shifted region was assumed from the proportional relationship between the pressure-flow characteristics and the spool displacement.

  13. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention

    Science.gov (United States)

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-01-01

    AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single institution study of consecutive patients who underwent sleeve gastrectomy from 2013 to 2015. Patients with previous bariatric procedures were excluded. Narrowing of a gastric sleeve includes: inability to pass a 9.6 mm gastroscope due to stenosis or sharp angulation or spiral hindering its passage. RESULTS Of 400 consecutive patients, 352 are included; the prevalence of dysphagia is 22.7%; 33 patients (9.3%) have narrowing of the sleeve with 25 (7.1%) having sharp angulation or a spiral while 8 (2.3%) have a stenosis. All 33 patients underwent balloon dilatation of the gastric sleeve and dysphagia resolved in 13 patients (39%); 10 patients (30%) noted resolution of dysphagia after two additional dilatations. In a multivariate model, medical conditions associated with post-operative dysphagia include diabetes mellitus, symptoms of esophageal reflux, a low whole blood thiamine level, hypothyroidism, use of non-steroidal anti-inflammatory drugs, and use of opioids. CONCLUSION Narrowing of the gastric sleeve and gastric sleeve stenosis are common after VSG. Endoscopic balloon dilatations of the gastric sleeve resolves dysphagia in 69% of patients. PMID:28058017

  14. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    International Nuclear Information System (INIS)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-01-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston–cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed. (paper)

  15. Characterization of a piezoelectric valve for an adaptive pneumatic shock absorber

    Science.gov (United States)

    Mikułowski, Grzegorz; Wiszowaty, Rafał; Holnicki-Szulc, Jan

    2013-12-01

    This paper describes a pneumatic valve based on a multilayer piezoelectric actuator and Hörbiger plates. The device was designed to operate in an adaptive pneumatic shock absorber. The adaptive pneumatic shock absorber was considered as a piston-cylinder device and the valve was intended to be installed inside the piston. The main objective for the valve application was regulating the gas flow between the cylinder’s chambers in order to maintain the desired value of the reaction force generated by the shock absorber. The paper describes the design constraints and requirements, together with results of analytical modelling of fluid flow verified versus experimentally obtained data. The presented results indicate that the desired performance characteristics of the valve were obtained. The geometrical constraints of the flow ducts were studied and the actuator’s functional features analysed.

  16. Using torque switch settings and spring pack characteristics to determine actuator output torques

    International Nuclear Information System (INIS)

    Black, B.R.

    1992-01-01

    Actuator output torque of motor operated valves is often a performance parameter of interest. It is not always possible to directly measure this torque. Torque spring pack deflection directly reflects actuator output torque and can be directly measured on most actuators. The torque spring pack may be removed from the actuator and tested to determine its unique force-deflection relationship. Or, a representative force-deflection relationship for the particular spring pack model may be available. With either relationship, measurements of torque spring pack deflection may then be correlated to corresponding forces. If the effective length of the moment arm within the actuator is known, actuator output torque can then be determined. The output torque is simply the product of the effective moment arm length and the spring pack force. This paper presents the reliability of this technique as indicated by testing. TU Electric is evaluating this technique for potential use in the future. Results presented in this paper should be considered preliminary. Applicability of these results may be limited to actuators and their components in a condition similar to those for which test data have been examined

  17. Assessing the efficiency of automatically controlled valves (ACV) for pipeline sectioning

    Energy Technology Data Exchange (ETDEWEB)

    Veiga, Leandro S. da; Silva, Marcos J.M. da; Leite, Joao Paulo de B.; Santos, Renata N.R. dos; Jardim, Rodrigo B.O.; Quinto, Thiago C. do [Petrobras Transporte S.A. (TRANSPETRO), Rio de Janeiro, RJ (Brazil)

    2009-07-01

    In order to mitigate the effects caused by the rupture of a gas pipeline and following ASME B 31.8 recommendations, block valves are installed in these structures. However, many transportation companies also install devices capable of infer the occurrence of an accident in a gas pipeline. The most common devices are the ones that actuate when pressure in gas pipeline reaches a low value early established (PSL) and those which close valves due to high rate of pressure drop (line-break). Line-break has the function of identifying as fast as possible the occurrence of a rupture in a gas pipeline by high rate of pressure drop in that line. Although PSL presents a later actuation when compared to the line break, it represents redundancy to the line-break system, since it is able to isolate the segment where the accident happened even if other devices or the operator had not done it before. The growing of gas pipelines transport capacity has been generated transients capable of causing an erroneous shut down of the shut down valves (SDV). The aim of this paper, therefore, is to present how the operational limits of SDV can be overcome with remote operation using SCADA System. (author)

  18. Fretting and Corrosion Damage in Taper Adapter Sleeves for Ceramic Heads: A Retrieval Study.

    Science.gov (United States)

    MacDonald, Daniel W; Chen, Antonia F; Lee, Gwo-Chin; Klein, Gregg R; Mont, Michael A; Kurtz, Steven M; Cates, Harold E; Kraay, Matthew J; Rimnac, Clare M

    2017-09-01

    During revision surgery with a well-fixed stem, a titanium sleeve can be used in conjunction with a ceramic head to achieve better stress distribution across the taper surface. In vitro testing suggests that corrosion is not a concern in sleeved ceramic heads; however, little is known about the in vivo fretting corrosion of the sleeves. The purpose of this study was to investigate fretting corrosion in sleeved ceramic heads in retrieved total hip arthroplasties. Thirty-seven sleeved ceramic heads were collected during revision. The femoral heads and sleeves were implanted 0.0-3.3 years. The implants were revised predominantly for instability, infection, and loosening. Fifty percent of the retrievals were implanted during a primary surgery. Fretting corrosion was assessed using the Goldberg-Higgs semiquantitative scoring system. Mild-to-moderate fretting corrosion scores (score = 2-3) were observed in 92% of internal tapers, 19% of external tapers, and 78% of the stems. Severe fretting corrosion was observed in 1 stem trunnion that was previously retained during revision surgery and none of the retrieved sleeves. There was no difference in corrosion damage of sleeves used in primary or revision surgery. The fretting corrosion scores in this study were predominantly mild and lower than reported fretting scores of cobalt-chrome heads in metal-on-polyethylene bearings. Although intended for use in revisions, we found that the short-term in vivo corrosion behavior of the sleeves was similar in both primary and revision surgery applications. From an in vivo corrosion perspective, sleeves are a reasonable solution for restoring the stem taper during revision surgery. Copyright © 2017. Published by Elsevier Inc.

  19. Bioinspired Soft Actuation System Using Shape Memory Alloys

    Directory of Open Access Journals (Sweden)

    Matteo Cianchetti

    2014-07-01

    Full Text Available Soft robotics requires technologies that are capable of generating forces even though the bodies are composed of very light, flexible and soft elements. A soft actuation mechanism was developed in this work, taking inspiration from the arm of the Octopus vulgaris, specifically from the muscular hydrostat which represents its constitutive muscular structure. On the basis of the authors’ previous works on shape memory alloy (SMA springs used as soft actuators, a specific arrangement of such SMA springs is presented, which is combined with a flexible braided sleeve featuring a conical shape and a motor-driven cable. This robot arm is able to perform tasks in water such as grasping, multi-bending gestures, shortening and elongation along its longitudinal axis. The whole structure of the arm is described in detail and experimental results on workspace, bending and grasping capabilities and generated forces are presented. Moreover, this paper demonstrates that it is possible to realize a self-contained octopus-like robotic arm with no rigid parts, highly adaptable and suitable to be mounted on underwater vehicles. Its softness allows interaction with all types of objects with very low risks of damage and limited safety issues, while at the same time producing relatively high forces when necessary.

  20. Valve Concepts for Microfluidic Cell Handling

    Directory of Open Access Journals (Sweden)

    M. Grabowski

    2010-01-01

    Full Text Available In this paper we present various pneumatically actuated microfluidic valves to enable user-defined fluid management within a microfluidic chip. To identify a feasible valve design, certain valve concepts are simulated in ANSYS to investigate the pressure dependent opening and closing characteristics of each design. The results are verified in a series of tests. Both the microfluidic layer and the pneumatic layer are realized by means of soft-lithographic techniques. In this way, a network of channels is fabricated in photoresist as a molding master. By casting these masters with PDMS (polydimethylsiloxane we get polymeric replicas containing the channel network. After a plasma-enhanced bonding process, the two layers are irreversibly bonded to each other. The bonding is tight for pressures up to 2 bar. The valves are integrated into a microfluidic cell handling system that is designed to manipulate cells in the presence of a liquid reagent (e.g. PEG – polyethylene glycol, for cell fusion. For this purpose a user-defined fluid management system is developed. The first test series with human cell lines show that the microfluidic chip is suitable for accumulating cells within a reaction chamber, where they can be flushed by a liquid medium.

  1. Use of color-coded sleeve shutters accelerates oscillograph channel selection

    Science.gov (United States)

    Bouchlas, T.; Bowden, F. W.

    1967-01-01

    Sleeve-type shutters mechanically adjust individual galvanometer light beams onto or away from selected channels on oscillograph papers. In complex test setups, the sleeve-type shutters are color coded to separately identify each oscillograph channel. This technique could be used on any equipment using tubular galvanometer light sources.

  2. Emergency core cooling device

    International Nuclear Information System (INIS)

    Suzaki, Kiyoshi; Inoue, Akihiro.

    1979-01-01

    Purpose: To improve core cooling effect by making the operation region for a plurality of water injection pumps more broader. Constitution: An emergency reactor core cooling device actuated upon failure of recycling pipe ways is adapted to be fed with cooling water through a thermal sleeve by way of a plurality of water injection pump from pool water in a condensate storage tank and a pressure suppression chamber as water feed source. Exhaust pipes and suction pipes of each of the pumps are connected by way of switching valves and the valves are switched so that the pumps are set to a series operation if the pressure in the pressure vessel is high and the pumps are set to a parallel operation if the pressure in the pressure vessel is low. (Furukawa, Y.)

  3. Main feedwater valve diagnostics at Waterford 3 nuclear generating station

    International Nuclear Information System (INIS)

    Fitzgerald, W.V.

    1991-01-01

    Pneumatically-operated control valves are coming under increasing scrutiny in nuclear power plants because of their relatively high incident rate. The theory behind a device that could make performance evaluation of these valves simpler and more effective was first described at the original EPRI Power Plant Valve Symposium. The development of this Diagnostic System was completed in 1989, and it was recently used to troubleshoot two main feedwater valves at Louisiana Power and Light's Waterford 3 Power Station. During a cold snap last December, these valves failed to respond to the input signal and, as a result, the plant came off line. An incident report had to be filed, and the plant chose to contact the original equipment manufacturer (OEM) for assistance. This paper describes the original incident involving these valves and then gives a brief description of the diagnostic system and how it works. The balance of the paper then reviews how the OEM and plant personnel utilized the system to evaluate each component of the control valve assembly (I/P transducer, positioner, volume boosters, actuator, and valve body assembly). By simply stroking the valve and monitoring pneumatic signals and valve position, the problem was traced to a malfunctioning positioner and a volume booster that was leaking. The problems were corrected and new performance signatures run for the valves using the system to document their improved operation. This case study demonstrates how new Diagnostic Technology along with OEM involvement can effectively address problems with pneumatically-operated control valves so that root-cause solutions can be implemented

  4. Safety relief valve alternate analysis method

    International Nuclear Information System (INIS)

    Adams, R.H.; Javid, A.; Khatua, T.P.

    1981-01-01

    An experimental test program was started in the United States in 1976 to define and quantify Safety Relief Valve (SRV) phenomena in General Electric Mark I Suppression Chambers. The testing considered several discharged devices and was used to correlate SRV load prediction models. The program was funded by utilities with Mark I containments and has resulted in a detailed SRV load definition as a portion of the Mark I containment program Load Definition Report (LDR). The (USNRC) has reviewed and approved the LDR SRV load definition. In addition, the USNRC has permitted calibration of structural models used for predicting torus response to SRV loads. Model calibration is subject to confirmatory in-plant testing. The SRV methodology given in the LDR requires that transient dynamic pressures be applied to a torus structural model that includes a fluid added mass matrix. Preliminary evaluations of torus response have indicated order of magnitude conservatisms, with respect to test results, which could result in unrealistic containment modifications. In addition, structural response trends observed in full-scale tests between cold pipe, first valve actuation and hot pipe, subsequent valve actuation conditions have not been duplicated using current analysis methods. It was suggested by others that an energy approach using current fluid models be utilized to define loads. An alternate SRV analysis method is defined to correct suppression chamber structural response to a level that permits economical but conservative design. Simple analogs are developed for the purpose of correcting the analytical response obtained from LDR analysis methods. Analogs evaluated considered forced vibration and free vibration structural response. The corrected response correlated well with in-plant test response. The correlation of the analytical model at test conditions permits application of the alternate analysis method at design conditions. (orig./HP)

  5. Modification and performance evaluation of a mono-valve engine

    Science.gov (United States)

    Behrens, Justin W.

    A four-stroke engine utilizing one tappet valve for both the intake and exhaust gas exchange processes has been built and evaluated. The engine operates under its own power, but has a reduced power capacity than the conventional 2-valve engine. The reduction in power is traced to higher than expected amounts of exhaust gases flowing back into the intake system. Design changes to the cylinder head will fix the back flow problems, but the future capacity of mono-valve engine technology cannot be estimated. The back flow of exhaust gases increases the exhaust gas recirculation (EGR) rate and deteriorates combustion. Intake pressure data shows the mono-valve engine requires an advanced intake valve closing (IVC) time to prevent back flow of charge air. A single actuation camshaft with advanced IVC was tested in the mono-valve engine, and was found to improve exhaust scavenging at TDC and nearly eliminated all charge air back flow at IVC. The optimum IVC timing is shown to be approximately 30 crank angle degrees after BDC. The mono-valve cylinder head utilizes a rotary valve positioned above the tappet valve. The open spaces inside the rotary valveand between the rotary valve and tappet valve represent a common volume that needs to be reduced in order to reduce the base EGR rate. Multiple rotary valve configurations were tested, and the size of the common volume was found to have no effect on back flow but a direct effect on the EGR rate and engine performance. The position of the rotary valve with respect to crank angle has a direct effect on the scavenging process. Optimum scavenging occurs when the intake port is opened just after TDC.

  6. Conceptual design of a compact absolute valve for the ITER neutral beam injectors

    Energy Technology Data Exchange (ETDEWEB)

    Jones, Chris [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom)], E-mail: chris.m.jones@jet.uk; Waldon, Chris; Martin, David; Watson, Mike [Euratom/UKAEA Fusion Association, Culham Science Centre, Abingdon, OX14 3DB (United Kingdom); Sonderegger, Kurt; Lenherr, Bruno [VAT Vakuumventile AG, CH-9469 Haag (Switzerland); Andrews, Ian; Mansbridge, Simon [VAT Vacuum Products Ltd., Edmund House, Rugby Road, Leamington Spa, Warwickshire CV32 6EL (United Kingdom)

    2009-06-15

    The reference design for the ITER neutral beam injectors incorporated a fast shutter to limit tritium migration to the injector vacuum enclosures. In 2005, a need for an 'absolute' isolation valve was identified to facilitate injector maintenance procedures and protect the system from an in-vessel ingress of coolant event (ICE). An outline concept for an all-metal seal valve was developed during 2006, in close cooperation with the Swiss valve manufacturer VAT. During the following year, it became apparent that the length of beamline available for the valve was significantly less than originally envisaged, resulting in a radical revision of the design concept. A casing length of 760 mm has been achieved by means of major changes to the casing structure, plate dimensions, pendulum mechanism and seal actuators. A concept for a seal protection system has been developed to prevent beam line contamination reaching the valve components and to protect the valve plate from surface heating by plasma radiation. The new design concept has been extensively validated by analysis, including a whole-system FE model of the valve.

  7. CFD simulation on flow induced vibrations in high pressure control and emergency stop turbine valve

    International Nuclear Information System (INIS)

    Lindqvist, H.

    2011-01-01

    During the refuelling outage at Unit 2 of Forsmark NPP in 2009, the high pressure turbine valves were replaced. Three month after recommissioning, an oil pipe connected to one of the actuators was broken. Measurements showed high-frequency vibration levels. The pipe break was suspected to be an effect of highly increased vibrations caused by the new valve. In order to establish the origin of the vibrations, investigations by means of CFD-simulations were made. The simulations showed that the increased vibrations most likely stems from the open cavity that the valves centre consists of. (author)

  8. Gastroesophageal Reflux Disease and Sleeve Gastrectomy.

    Science.gov (United States)

    Melissas, John; Braghetto, Italo; Molina, Juan Carlos; Silecchia, Gianfranco; Iossa, Angelo; Iannelli, Antonio; Foletto, Mirto

    2015-12-01

    Gastroesophageal reflux disease (GERD) and/or hiatus hernia (HH) are one of the most common disorders of the upper gastrointestinal tract. Despite the positive effect of sleeve gastrectomy (SG) regarding weight loss and improvement in obesity co-morbidities, there are concerns about the development of de novo gastroesophageal reflux disease or worsening the existing GERD after this bariatric operation. Furthermore, controversy exists on the consequences of SG in lower esophageal sphincter function and about the ideal procedure when a hiatus hernia is preoperatively diagnosed or discovered during the laparoscopic SG. This review systematically investigates the incidence, the pathophysiology of GERD and/or HH in morbidly obese individuals before and after SG, and the treatment options for concomitant HH repair during laparoscopic sleeve gastrectomy.

  9. Recent experience with testing of parallel disc gate valves under accident flow conditions

    International Nuclear Information System (INIS)

    LaPointe, P.A.; Clayton, J.K.

    1992-01-01

    This paper presents the nuclear valve industry's latest and most extensive valve qualification test program experience. The test program includes a variety of 25 different gate and globe valves. All the test valves are power operated using either air, electric, or gas/hydraulic operators. The valves are categorized in size and pressure class so as to form a group of appropriate parent valve assemblies. Parent valve assembly qualification is used as the basis for qualification of candidate valve assemblies. The parent and candidate valve assemblies are representative of a nuclear plant's safety-related valve applications. The test program was performed in accordance with ANSI B16.41-1983 'Functional Qualification Requirements for Power Operated Active Valve Assemblies for Nuclear Power Plants.' The focus of this paper is on functional valve qualification test experience and specifically flow interruption testing to Annex G of the aforementioned test standard. Results of the flow test are summarized, including the coefficient of friction for each of the gate type valves reported. Information on valve size, pressure class, and actuator are given for all valves in the program. Although all valves performed extremely well, only selected test data are presented. The effects of the speed of operation and the effects of different fluid flow rates as they relate to the coefficient of friction between the valve disc and seat are discussed. The variation in the coefficient of friction based on other variables in the thrust equation, namely, differential pressure area is cited

  10. Automation Activator of Hydrogen Gas Inlet Valve on Reduction Furnace ME-11

    International Nuclear Information System (INIS)

    Achmad Suntoro

    2007-01-01

    Operational of hydrogen inlet valve of the reduction furnace ME-11 was actuated manually by furnace operator if all its requirements have been fulfilled. Automation of the valve has been constructed as an additional option of the furnace operating system, in which any interruption by the existing manual system by the operator is still valid even though the automatic option is being used. This paper describes the information concerning the automation construction and its logical status of control in the form of its finite state machine. This automation system has been tested successfully. (author)

  11. Development of on line automatic separation device for apple and sleeve

    Science.gov (United States)

    Xin, Dengke; Ning, Duo; Wang, Kangle; Han, Yuhang

    2018-04-01

    Based on STM32F407 single chip microcomputer as control core, automatic separation device of fruit sleeve is designed. This design consists of hardware and software. In hardware, it includes mechanical tooth separator and three degree of freedom manipulator, as well as industrial control computer, image data acquisition card, end effector and other structures. The software system is based on Visual C++ development environment, to achieve localization and recognition of fruit sleeve with the technology of image processing and machine vision, drive manipulator of foam net sets of capture, transfer, the designated position task. Test shows: The automatic separation device of the fruit sleeve has the advantages of quick response speed and high separation success rate, and can realize separation of the apple and plastic foam sleeve, and lays the foundation for further studying and realizing the application of the enterprise production line.

  12. Initial data collection efforts of CREDO. Sodium valve failures

    International Nuclear Information System (INIS)

    Bott, T.F.; Haas, P.M.

    1978-01-01

    The Centralized Reliability Data organisation (CREDO) has been established at Oak Ridge National Laboratory to define, develop, and maintain a reliability data analysis center for use in advanced reactor safety and licensing. Its primary functions are collection, reduction, evaluation, storage, retrieval, and dissemination of reliability/maintainability data. Data-collection efforts have been initiated at several test loops, at the Experimental Breeder Reactor-II and at the Fast Flux Test Facility. Top priority is being given to collection data on safety and safety-related systems, primarily for sodium-cooled reactors. Sufficient operating time has been accumulated on sodium valves at test facilities to provide quantitative estimates of reliability characteristics with a reasonable degree of confidence. Sodium-valve failures have been categorized according to seat design, size, seal type, and actuator type. Attempts have been made to establish the variation of failure rate with time and duty. Estimates of failure rates for sodium valves have been compared to those for water valves and appear to be of the same order of magnitude. (author)

  13. Design and performance analysis of position-based impedance control for an electrohydrostatic actuation system

    Directory of Open Access Journals (Sweden)

    Yongling FU

    2018-03-01

    Full Text Available Electrohydrostatic actuator (EHA is a type of power-by-wire actuator that is widely implemented in the aerospace industry for flight control, landing gears, thrust reversers, thrust vector control, and space robots. This paper presents the development and evaluation of position-based impedance control (PBIC for an EHA. Impedance control provides the actuator with compliance and facilitates the interaction with the environment. Most impedance control applications utilize electrical or valve-controlled hydraulic actuators, whereas this work realizes impedance control via a compact and efficient EHA. The structures of the EHA and PBIC are firstly introduced. A mathematical model of the actuation system is established, and values of its coefficients are identified by particle swarm optimization. This model facilitates the development of a position controller and the selection of target impedance parameters. A nonlinear proportional-integral position controller is developed for the EHA to achieve the accurate positioning requirement of PBIC. The controller compensates for the adverse effect of stiction, and a position accuracy of 0.08 mm is attained. Various experimental results are presented to verify the applicability of PBIC to the EHA. The compliance of the actuator is demonstrated in an impact test. Keywords: Actuation system, Aerospace, Electrohydrostatic actuator, Force control, Nonlinear dynamics, Particle swarm optimization, Position control

  14. Esophageal adenocarcinoma five years after laparoscopic sleeve gastrectomy. A case report

    Directory of Open Access Journals (Sweden)

    Fernando Gabriel Wright

    2017-01-01

    Conclusion: We present a case of an esophageal adenocarcinoma five years after a laparoscopic sleeve gastrectomy for morbid obesity. There is need to better determine the relationship between sleeve gastrectomy and gastroesophageal reflux disease in order to prevent its related complications, such as esophageal adenocarcinoma.

  15. Valve-sparing aortic root replacement in Loeys-Dietz syndrome.

    Science.gov (United States)

    Patel, Nishant D; Arnaoutakis, George J; George, Timothy J; Allen, Jeremiah G; Alejo, Diane E; Dietz, Harry C; Cameron, Duke E; Vricella, Luca A

    2011-08-01

    Loeys-Dietz syndrome (LDS) is a recently recognized aggressive aortic disorder characterized by root aneurysm, arterial tortuosity, hypertelorism, and bifid uvula or cleft palate. The results of prophylactic root replacement using valve-sparing procedures (valve-sparing root replacement [VSRR]) in patients with LDS is not known. We reviewed all patients with clinical and genetic (transforming growth factor-β receptor mutations) evidence of LDS who underwent VSRR at our institution. Echocardiographic and clinical data were obtained from hospital and follow-up clinic records. From 2002 to 2009, 31 patients with a firm diagnosis of LDS underwent VSRR for aortic root aneurysm. Mean age was 15 years, and 24 (77%) were children. One (3%) patient had a bicuspid aortic valve. Preoperative sinus diameter was 3.9±0.8 cm (z score 7.0±2.9) and 2 (6%) had greater than 2+ aortic insufficiency. Thirty patients (97%) underwent reimplantation procedures using a Valsalva graft. There were no operative deaths. Mean follow-up was 3.6 years (range, 0 to 7 years). One patient required late repair of a pseudoaneurysm at the distal aortic anastomosis, and 1 had a conversion to a David reimplantation procedure after a Florida sleeve operation. No patient suffered thromboembolism or endocarditis, and 1 (3%) patient experienced greater than 2+ late aortic insufficiency. No patient required late aortic valve repair or replacement. Loeys-Dietz syndrome is an aggressive aortic aneurysm syndrome that can be addressed by prophylactic aortic root replacement with low operative risk. Valve-sparing procedures have encouraging early and midterm results, similar to those in Marfan syndrome, and are an attractive option for young patients. Copyright © 2011 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  16. Robust PID Controller for a Pneumatic Actuator

    Directory of Open Access Journals (Sweden)

    Skarpetis Michael G.

    2016-01-01

    Full Text Available In this paper the position control pneumatic actuator using a robust PID controller is presented. The parameters of the PID controller are computed using a Hurwitz invariability technique enriched with a Simulated Annealing Algorithm. The nonlinear model involves uncertain parameters due to linearization of the servo valve, variations of the initial volume of the cylinder and variation of the external load. The problem is proven to be solvable and the controller parameters are chosen to provide a suboptimal solution for tracking error minimization. Simulation results are presented for the nonlinear model.

  17. A Computational Study on Hydrodynamic Torque Coefficients of a Butterfly Valve

    International Nuclear Information System (INIS)

    Lee, Do-Hwan; Park, Sung-Keun; Kang, Shin-Chul; Kim, Dae-Woong; Park, Ju-Yeop

    2007-01-01

    Butterfly valves have been widely used for on-off or control purposes in the process industry, since they provide quick opening and closing operation and good flow control characteristics. For the evaluation of the adequacy of valve operability and the actuator sizing, the required torque estimation is necessary. Since the principal contributing component of the require torque in the mid-stroke position is hydrodynamic torque, it is necessary to predict the torque properly under the actual flow conditions. The research on the prediction of the valve performance was led by EPRI (Electric Power Research Institute) in early 1990s. A performance prediction model was developed based on the experimental results and the free-streamline analysis by Sarpkaya. Recently, Kalsi Engineering carried out extended tests and developed the improved model. Variation of disk geometries and upstream flow conditions were tried to obtain accurate hydrodynamic torque coefficients. However, since the model is only commercially available, a general method to obtain hydrodynamic torque for butterfly valves is called for

  18. Application of hydraulic network analysis to motor operated butterfly valves in nuclear power plants

    International Nuclear Information System (INIS)

    Eldiwany, B.H.; Kalsi, M.S.

    1992-01-01

    This paper presents the application of hydraulic network analysis to evaluate the performance of butterfly valves in nuclear power plant applications. Required actuation torque for butterfly valves in high-flow applications is often dictated by peak dynamic torque. The peak dynamic torque, which occurs at some intermediate disc position, requires accurate evaluation of valve flow rate and pressure drop throughout the valve stroke. Valve flow rate and pressure drop are significantly affected by the valve flow characteristics and the hydraulic system characteristics, such as pumping capability, piping resistances, single and parallel flow paths, system hydrostatic pressure, and the location of the motor-operated valve (MOV) within the system. A hydraulic network analysis methodology that addresses the effect of these parameters on the MOV performance is presented. The methodology is based on well-established engineering principles. The application of this methodology requires detailed characteristics of both the MOV and the hydraulic system in which it is installed. The valve characteristics for this analysis can be obtained by flow testing or from the valve manufacturer. Even though many valve users, valve manufacturers, and engineering standards have recognized the importance of performing these analyses, none has provided a detailed procedure for doing so

  19. Lateral Dynamics of Flexible Rotors Supported by Controllable Gas Bearings Theory & Experiment

    DEFF Research Database (Denmark)

    Pierart Vásquez, Fabián Gonzalo; Santos, Ilmar

    2015-01-01

    Active gas bearings might represent a mechatronic answer to the growing industrial need for high performance turbomachinery. In this framework, the paper gives a theoretical and experimental contribution to the improvement of lateral dynamics of rotating machines. The work aims at demonstrating...... theoretically as well as experimentally the feasibility of applying active lubrication to gas journal bearings. The operation principle is to generate active forces by regulating the radial injection of a compressible lubricant (gas) by means of piezoelectric actuators mounted on the back of the bearing sleeve....... The active control principle is built using eddy-current sensor signals to detect the lateral motion of the rotor. A feedback law is used to couple the lateral dynamics of a flexible rotor-bearing system with the pneumatic and dynamic characteristics of a piezoelectric actuated valve system. A proportional...

  20. Butterfly valve with metal seals controls flow of hydrogen from cryogenic through high temperatures

    Science.gov (United States)

    Johnson, L. D.

    1967-01-01

    Butterfly valve with metal seals operates over a temperature range of minus 423 degrees to plus 440 degrees F with hydrogen as a medium and in a radiation environment. Media flow is controlled by an internal butterfly disk which is rotated by an actuation shaft.

  1. An investigation of the effects of pneumatic actuator design on slip control for heavy vehicles

    Science.gov (United States)

    Miller, Jonathan I.; Cebon, David

    2013-01-01

    Progress in reducing actuator delays in pneumatic brake systems is opening the door for advanced anti-lock braking algorithms to be used on heavy goods vehicles. However, little has been published on slip controllers for air-braked heavy vehicles, or the effects of slow pneumatic actuation on their design and performance. This paper introduces a sliding mode slip controller for air-braked heavy vehicles. The effects of pneumatic actuator delays and flow rates on stopping performance and air (energy) consumption are presented through vehicle simulations. Finally, the simulations are validated with experiments using a hardware-in-the-loop rig. It is shown that for each wheel, pneumatic valves with delays smaller than 3 ms and orifice diameters around 8 mm provide the best performance.

  2. Experimental characterization of the hysteretic and rate-dependent electromechanical behavior of dielectric electro-active polymer actuators

    International Nuclear Information System (INIS)

    York, A; Seelecke, S; Dunn, J

    2010-01-01

    Dielectric electro-active polymers (DEAPs) can achieve substantial deformation (>300% strain) while sustaining, compared to their ionic counterparts, large forces. This makes them attractive for various actuation and sensing applications such as in light weight and energy efficient valve and pumping systems. Many applications operate DEAP actuators at higher frequencies where rate-dependent effects influence their performance. This motivates the seeking of dynamic characterization of these actuators beyond the quasi-static regime. This paper provides a systematic experimental investigation of the quasi-static and dynamic electromechanical properties of a DEAP actuator. In order to completely characterize the fully coupled behavior, force versus displacement measurements at various constant voltages and force versus voltage measurements at various fixed displacements are conducted. The experiments are conducted with a particular focus on the hysteretic and rate-dependent material behavior. These experiments provide insight into the electrical dynamics and viscoelastic relaxation inherent in DEAP actuators. This study is intended to provide information, including high frequency performance analysis, useful to anyone designing dynamic actuator systems using DEAPs

  3. Pressure tracking control of vehicle ABS using piezo valve modulator

    Science.gov (United States)

    Jeon, Juncheol; Choi, Seung-Bok

    2011-03-01

    This paper presents a wheel slip control for the ABS(anti-lock brake system) of a passenger vehicle using a controllable piezo valve modulator. The ABS is designed to optimize for braking effectiveness and good steerability. As a first step, the principal design parameters of the piezo valve and pressure modulator are appropriately determined by considering the braking pressure variation during the ABS operation. The proposed piezo valve consists of a flapper, pneumatic circuit and a piezostack actuator. In order to get wide control range of the pressure, the pressure modulator is desired. The modulator consists of a dual-type cylinder filled with different substances (fluid and gas) and a piston rod moving vertical axis to transmit the force. Subsequently, a quarter car wheel slip model is formulated and integrated with the governing equation of the piezo valve modulator. A sliding mode controller to achieve the desired slip rate is then designed and implemented. Braking control performances such as brake pressure and slip rate are evaluated via computer simulations.

  4. A Study of System Pressure Transients Generated by Isolation Valve Open/Closure in Orifice Manifold

    Energy Technology Data Exchange (ETDEWEB)

    Kim, M. [KEPCO, Daejeon (Korea, Republic of); Bae, S. W.; Kim, J. I.; Park, S. J. [KHNP, Abu Dhabi (United Arab Emirates)

    2016-05-15

    In this study, we explore the effects of pressure transients on peak and minimal pressures caused by the actuation of isolation valve and control valve reacting to the combined orifice operation of orifice manifold with motor-operated valve installed in the rear of the orifice. We then use the collected data to direct our effort towards cause analysis and propose improvements to efficiency and safety of operation. This formation is used to by domestic and foreign nuclear power plants as a mean to control flow rate, producing required flow rate jointly together by combination of the orifices. No significant impacts on the internals of manifold orifice due to peak pressure has been observed, although chance of cavitation at the outlet of control valve is significant. Considering the peak pressure, as well as minimum pressure occurs in low flow rate conditions, the pressure transient is more so affected by the characteristics (modified equal percentage) of control valve. Isolation valve of the orifice and control valve operate organically, therefore stroke time for valves need to be applied in order for both valves to cooperatively formulate an optimized operation.

  5. Left lower lobe sleeve lobectomy for lung cancer using the Da Vinci surgical system.

    Science.gov (United States)

    Zhao, Yandong; Jiao, Wenjie; Ren, Xiaoyang; Zhang, Liangdong; Qiu, Tong; Fu, Bo; Wang, Lei

    2016-04-12

    Despite the robotic surgery is widely applied, sleeve lobectomy for lung cancer using the Da Vinci surgical system is still less performed. We described a sleeve lobectomy for adenocarcinoma located at the left lower lobe using the Da Vinci surgical system. A case of 57-year old female referred to our hospital. Computed tomography scan showed an occupation located at the left lower lobe and adenocarcinoma project from the lobe bronchus was diagnosed by bronchoscope examination. A sleeve lobectomy was performed using the Da Vinci surgical system and the postoperative recovery was uneventful. Robotic thoracic surgery is feasible to perform sleeve lobectomy inspite of inadequate experience.

  6. What caused the failures of the solenoid valve screws

    International Nuclear Information System (INIS)

    Vassallo, T.P.; Mumford, J.R.; Hossain, F.

    2001-01-01

    At Seabrook Station on May 5,1998 following a lengthy purge of the pressurizer steam space through Containment isolation sample valve 1-RC-FV-2830, the UL status light associated with this solenoid valve did not come on when the valve was closed from the plant's main control board. The UL status light is used to confirm valve closure position to satisfy the plant's Technical Specification requirements. The incorrect valve position indication on the main control board was initially believed to have resulted from excessive heat from a failed voltage control module that did not reduce the voltage to the valve's solenoid coil. This conclusion was based on a similar event that occurred in November of 1996. Follow-up in-plant testing of the valve determined that the voltage control module had not failed and was functioning satisfactorily. Subsequent investigations determined the root cause of the event to be excessive heat-up of the valve caused by high process fluid temperature and an excessively long purge of the pressurizer. The excessive heat-up of the valve from the high temperature process fluid weakened the magnetic field strength of the valve stem magnet to the extent that the UL status light reed switch would not actuate when the valve was closed. Since the voltage control module was tested and found to be functioning properly it was not replaced. Only the UL status light reed switch was replaced with a more sensitive reed that would respond better to a reduced magnetic field strength that results from a hot magnet. During reed switch replacement, three terminal block screws in the valve housing were found fractured and three other terminal block screws fractured during determination of the electrical conductors. This paper describes the initial plant event and ensuing laboratory tests and examinations that were performed to determine the root cause of the failure of the terminal block screws from the Containment isolation sample solenoid valve. (author)

  7. Sleeve Push Technique: A Novel Method of Space Gaining.

    Science.gov (United States)

    Verma, Sanjeev; Bhupali, Nameksh Raj; Gupta, Deepak Kumar; Singh, Sombir; Singh, Satinder Pal

    2018-01-01

    Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel-titanium open coil springs. The disadvantage of nickel-titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT). The nickel-titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing) can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel-titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.

  8. Sleeve push technique: A novel method of space gaining

    Directory of Open Access Journals (Sweden)

    Sanjeev Verma

    2018-01-01

    Full Text Available Space gaining is frequently required in orthodontics. Multiple loops were initially used for space gaining and alignment. The most common used mechanics for space gaining is the use of nickel–titanium open coil springs. The disadvantage of nickel–titanium coil spring is that they cannot be used until the arches are well aligned to receive the stiffer stainless steel wires. Therefore, a new method of gaining space during initial alignment and leveling has been developed and named as sleeve push technique (SPT. The nickel–titanium wires, i.e. 0.012 inches and 0.014 inches along with archwire sleeve (protective tubing can be used in a modified way to gain space along with alignment. This method helps in gaining space right from day 1 of treatment. The archwire sleeve and nickel–titanium wire in this new SPT act as a mutually synergistic combination and provide the orthodontist with a completely new technique for space opening.

  9. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    International Nuclear Information System (INIS)

    Mahrous, A-F.M.; Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P.

    2009-01-01

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing

  10. A modelling study into the effects of variable valve timing on the gas exchange process and performance of a 4-valve DI homogeneous charge compression ignition (HCCI) engine

    Energy Technology Data Exchange (ETDEWEB)

    Mahrous, A-F.M. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom); Lecturer at the Department of Mechanical Power Engineering, Faculty of Engineering (Shebin El-Kom), Menoufiya University, Shebin El-Kom (Egypt); Potrzebowski, A.; Wyszynski, M.L.; Xu, H.M.; Tsolakis, A.; Luszcz, P. [School of Mechanical Engineering, University of Birmingham, Edgbaston, Birmingham B15 2TT (United Kingdom)

    2009-02-15

    Homogeneous charge compression ignition (HCCI) combustion mode is a relatively new combustion technology that can be achieved by using specially designed cams with reduced lift and duration. The auto-ignition in HCCI engine can be facilitated by adjusting the timing of the exhaust-valve-closing and, to some extent, the timing of the intake-valve-opening so as to capture a proportion of the hot exhaust gases in the engine cylinder during the gas exchange process. The effects of variable valve timing strategy on the gas exchange process and performance of a 4-valve direct injection HCCI engine were computationally investigated using a 1D fluid-dynamic engine cycle simulation code. A non-typical intake valve strategy was examined; whereby the intake valves were assumed to be independently actuated with the same valve-lift profile but at different timings. Using such an intake valves strategy, the obtained results showed that the operating range of the exhaust-valve-timing within which the HCCI combustion can be facilitated and maintained becomes much wider than that of the typical intake-valve-timing case. Also it was found that the engine parameters such as load and volumetric efficiency are significantly modified with the use of the non-typical intake-valve-timing. Additionally, the results demonstrated the potential of the non-typical intake-valve strategy in achieving and maintaining the HCCI combustion at much lower loads within a wide range of valve timings. Minimizing the pumping work penalty, and consequently improving the fuel economy, was shown as an advantage of using the non-typical intake-valve-timing with the timing of the early intake valve coupled with a symmetric degree of exhaust-valve-closing timing. (author)

  11. Explosion-proof actuators according to EU directive 94/9/EC (ATEX)

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, M. [AUMA Riester GmbH und Co. KG. Muellheim (Germany)

    2004-07-01

    Since July, 1, 2003 only explosion-proof devices which conform to the new EU Directive 94/9/EC, better known as the ATEX Directive, are introduced to the market. Especially the explosion protection of non-electrical equipment is a completely new task for many manufacturers. AUMA has qualified its electric actuators for the automation of industrial valves in accordance with the new regulations. In addition the design has been improved. (orig.)

  12. A solar energy powered autonomous wireless actuator node for irrigation systems.

    Science.gov (United States)

    Lajara, Rafael; Alberola, Jorge; Pelegrí-Sebastiá, José

    2011-01-01

    The design of a fully autonomous and wireless actuator node ("wEcoValve mote") based on the IEEE 802.15.4 standard is presented. The system allows remote control (open/close) of a 3-lead magnetic latch solenoid, commonly used in drip irrigation systems in applications such as agricultural areas, greenhouses, gardens, etc. The very low power consumption of the system in conjunction with the low power consumption of the valve, only when switching positions, allows the system to be solar powered, thus eliminating the need of wires and facilitating its deployment. By using supercapacitors recharged from a specifically designed solar power module, the need to replace batteries is also eliminated and the system is completely autonomous and maintenance free. The "wEcoValve mote" firmware is based on a synchronous protocol that allows a bidirectional communication with a latency optimized for real-time work, with a synchronization time between nodes of 4 s, thus achieving a power consumption average of 2.9 mW.

  13. Dysphagia after vertical sleeve gastrectomy: Evaluation of risk factors and assessment of endoscopic intervention

    OpenAIRE

    Nath, Anand; Yewale, Sayali; Tran, Tung; Brebbia, John S; Shope, Timothy R; Koch, Timothy R

    2016-01-01

    AIM To evaluate the risks of medical conditions, evaluate gastric sleeve narrowing, and assess hydrostatic balloon dilatation to treat dysphagia after vertical sleeve gastrectomy (VSG). METHODS VSG is being performed more frequently worldwide as a treatment for medically-complicated obesity, and dysphagia is common post-operatively. We hypothesize that post-operative dysphagia is related to underlying medical conditions or narrowing of the gastric sleeve. This is a retrospective, single insti...

  14. Patellar Sleeve Fracture With Ossification of the Patellar Tendon.

    Science.gov (United States)

    Damrow, Derek S; Van Valin, Scott E

    2017-03-01

    Patellar sleeve fractures make up greater than 50% of all patellar fractures. They are essentially only seen in the pediatric population because of the thick periosteum and the distal patellar pole apophysis in this group. These fractures can lead to complications if not treated appropriately and in a timely fashion. Complications of missed or untreated patellar sleeve fractures include patella alta, anterior knee pain, and quadriceps atrophy. These can all result in severe limitations in activity. The authors describe a case of a 16-year-old boy who sustained a patellar sleeve fracture 3 years prior to presentation. On presentation, he had patella alta, diminished strength, 5° of extensor lag, and radiographs that revealed bone formation along the patellar tendon. Despite this, he was able to maintain a high level of activity. This case report explores how the patient could have maintained a high level of activity despite having a patellar sleeve fracture. Also, because of the delayed presentation, the patella was ossified and the quadriceps was retracted, which led to a novel approach to reconstructing his distal extensor mechanism. This approach included a V-Y advancement of the quadriceps tendon and patellar tendon reconstruction using the patient's hamstring tendon (semitendinosus). This technique, combined with physical therapy postoperatively, resulted in his return to varsity high school soccer. To the best of the authors' knowledge, this technique has not been reported for this rare condition. [Orthopedics. 2017; 40(2):e357-e359.]. Copyright 2016, SLACK Incorporated.

  15. Control Valve Stiction Identification, Modelling, Quantification and Control - A Review

    Directory of Open Access Journals (Sweden)

    Srinivasan Arumugam

    2011-09-01

    Full Text Available Most of the processes found in process industries exhibit undesirable nonlinearity due to backlash, saturation, hysteresis, stiction (friction, dead-zone and stuck-fault existing in control valves. The control valve is the actuator for most process control loops and, as the only moving part in the loop, its function is to implement the control action. If the control valve malfunctions, the performance of the control loop is likely to deteriorate, no matter how good the controller is. Commonly encountered control valve problems include nonlinear responses to the demand signal caused by effects such as stiction, dead-band or saturation. Because of these problems, the control loop may be oscillatory, which in turn may cause oscillations in many process variables causing a range of operational problems including increased valve wear. Understanding nonlinear behaviour of control valves in order to maintain the quality of the end products in the industry, this review article surveys the identification, modelling, estimation and design of dynamic models of stiction nonlinearity and providing appropriate controller to obtain optimum responses of the process. The primary objective of this work is to present state-of-art-review of common nonlinear problems associated with mechanical and chemical processes for encouraging researchers, practicing engineers working in this field, so that readers can invent their goals for future research work on nonlinear systems identification and control.

  16. Thimble grip fuel assembly handling tool

    International Nuclear Information System (INIS)

    Salton, R.B.; Hornak, L.P.; Marshall, J.R.; Meuschke, R.E.

    1989-01-01

    This patent describes an apparatus for lifting a fuel assembly of a nuclear reactor. The fuel assembly consists of a top nozzle and control rod guide tubes. The apparatus having a gripping means comprised of: a life plate, an actuating plate having a plurality of apertures, the actuating plate disposed in spaced relationship below the lift plate and vertically movable relative thereto; gripping members operably associated with the lift and actuating plates, the gripping members comprising: (a) a vertical rod fixedly secured near its top end to the lift plate and projecting downward therefrom through an associated aperture in the actuating plate, the rod having a first frustoconical surface formed near its lower end, (b) a generally cylindrical, elastically deformable vertical sleeve having a bore therethrough with a first inner diameter, the sleeve having a first bevelled inside surface near the top end and a second bevelled inside surface at the bottom end of the sleeve, and (c) a vertical gripper actuator disposed about the rod

  17. Numerical and experimental investigation of flow and heat transfer in a T-junction with thermal sleeve

    International Nuclear Information System (INIS)

    Wu Hailing; Chen Tingkuan; Wang Haijun; Luo Yushan; Mao Qing; Zhang Yixiong

    2002-01-01

    Numerical simulations were performed with the commercial computational fluid dynamics (CFD) package FLUENT 5.3 to investigate the thermal-hydraulic phenomena of thermal shock, which is caused by non-isothermal turbulent jet into crossflow in a T-junction with thermal sleeve in the pressurized water reactor (PWR) cooling systems. In allusion to the thermal sleeve configuration with vent holes and lower collar, two typical cases with jet-to-mainstream velocity ratios of 0.05 and 0.5 were computed. Experimental studies were carried out to determine the heat transfer characteristics for the main pipe and the annulus between the nozzle and the thermal sleeve. The calculations well matches the experimental data. The results indicated that the protective action of the thermal sleeve against thermal shock loading is dependent on both the sleeve geometry and the velocity ratio, obtaining improvement with appropriate lower velocity ratios. In addition, optimal flow rates and partial sizes of the thermal sleeve were discussed to reduce the thermal shock

  18. Magnetic Actuation Connector Between Extension Shaft and Armature for Bottom Mounted Control Rod Drive Mechanism

    Energy Technology Data Exchange (ETDEWEB)

    Huh, Hyung; Cho, Yeong Garp; Kim, Jong In [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The electromagnet and armature inside the guide tube interact and produce magnetism, thus making the armature, connecting extension shaft and control rod move up and down to control the power of reactor. During the overhaul, the control absorber rod (CAR), extension shaft, and armature of BMCRDM are lifted together for closing a seal valve. But total length of CAR assembly is so long that it cannot be lifted due to exposure above the water level of pool which is strictly controlled. In addition to this, it is difficult to calibrate a position indicator and lifting force of electromagnet without armature assembly as a seal valve is closed. For this reason, it is necessary to install a disconnecting system between armature and extension shaft. Therefore, KAERI has developed magnetic actuation connector using plunger between armature and extension shaft for the bottom mounted control rod drive mechanism in research reactor. The results of a FEM and the experiments in this work lead to the following conclusions: The FEM result for the design of the magnetic actuation connector is compared with the measured lifting force of prototype production. As a result, it is shown that the lifting force of the prototype connector has a good agreement with the result of the FEM. A newly developed technique of prototype magnetic actuation connector which is designed by FEM analysis result is proposed.

  19. Magnetic Actuation Connector Between Extension Shaft and Armature for Bottom Mounted Control Rod Drive Mechanism

    International Nuclear Information System (INIS)

    Huh, Hyung; Cho, Yeong Garp; Kim, Jong In

    2013-01-01

    The electromagnet and armature inside the guide tube interact and produce magnetism, thus making the armature, connecting extension shaft and control rod move up and down to control the power of reactor. During the overhaul, the control absorber rod (CAR), extension shaft, and armature of BMCRDM are lifted together for closing a seal valve. But total length of CAR assembly is so long that it cannot be lifted due to exposure above the water level of pool which is strictly controlled. In addition to this, it is difficult to calibrate a position indicator and lifting force of electromagnet without armature assembly as a seal valve is closed. For this reason, it is necessary to install a disconnecting system between armature and extension shaft. Therefore, KAERI has developed magnetic actuation connector using plunger between armature and extension shaft for the bottom mounted control rod drive mechanism in research reactor. The results of a FEM and the experiments in this work lead to the following conclusions: The FEM result for the design of the magnetic actuation connector is compared with the measured lifting force of prototype production. As a result, it is shown that the lifting force of the prototype connector has a good agreement with the result of the FEM. A newly developed technique of prototype magnetic actuation connector which is designed by FEM analysis result is proposed

  20. Corrugated paraffin nanocomposite films as large stroke thermal actuators and self-activating thermal interfaces.

    Science.gov (United States)

    Copic, Davor; Hart, A John

    2015-04-22

    High performance active materials are of rapidly growing interest for applications including soft robotics, microfluidic systems, and morphing composites. In particular, paraffin wax has been used to actuate miniature pumps, solenoid valves, and composite fibers, yet its deployment is typically limited by the need for external volume constraint. We demonstrate that compact, high-performance paraffin actuators can be made by confining paraffin within vertically aligned carbon nanotube (CNT) films. This large-stroke vertical actuation is enabled by strong capillary interaction between paraffin and CNTs and by engineering the CNT morphology by mechanical compression before capillary-driven infiltration of the molten paraffin. The maximum actuation strain of the corrugated CNT-paraffin films (∼0.02-0.2) is comparable to natural muscle, yet the maximum stress is limited to ∼10 kPa by collapse of the CNT network. We also show how a CNT-paraffin film can serve as a self-activating thermal interface that closes a gap when it is heated. These new CNT-paraffin film actuators could be produced by large-area CNT growth, infiltration, and lamination methods, and are attractive for use in miniature systems due to their self-contained design.

  1. Numerical simulation of axisymmetric valve operation for different outer cone angle

    Science.gov (United States)

    Smyk, Emil

    One of the method of flow separation control is application of axisymmetric valve. It is composed of nozzle with core. Normally the main flow is attached to inner cone and flow by preferential collector to primary flow pipe. If through control nozzle starts flow jet (control jet) the main flow is switched to annular secondary collector. In both situation the main flow is deflected to inner or outer cone (placed at the outlet of the valve's nozzle) by Coanda effect. The paper deals with the numerical simulation of this axisymetric annular nozzle with integrated synthetic jet actuator. The aim of the work is influence examination of outer cone angle on deflection on main stream.

  2. Dielectric Barrier Discharge (DBD) Plasma Actuators Thrust-Measurement Methodology Incorporating New Anti-Thrust Hypothesis

    Science.gov (United States)

    Ashpis, David E.; Laun, Matthew C.

    2014-01-01

    We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a large diameter, grounded, metal sleeve.

  3. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar

    International Nuclear Information System (INIS)

    Porto Junior, Almir Carlos Soares

    2014-01-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009 th by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals

  4. Bioprosthetic Valve Fracture to Facilitate Transcatheter Valve-in-Valve Implantation.

    Science.gov (United States)

    Allen, Keith B; Chhatriwalla, Adnan K; Cohen, David J; Saxon, John T; Aggarwal, Sanjeev; Hart, Anthony; Baron, Suzanne; Davis, J Russell; Pak, Alex F; Dvir, Danny; Borkon, A Michael

    2017-11-01

    Valve-in-valve transcatheter aortic valve replacement is less effective in small surgical bioprostheses. We evaluated the feasibility of bioprosthetic valve fracture with a high-pressure balloon to facilitate valve-in-valve transcatheter aortic valve replacement. In vitro bench testing on aortic tissue valves was performed on 19-mm and 21-mm Mitroflow (Sorin, Milan, Italy), Magna and Magna Ease (Edwards Lifesciences, Irvine, CA), Trifecta and Biocor Epic (St. Jude Medical, Minneapolis, MN), and Hancock II and Mosaic (Medtronic, Minneapolis, MN). High-pressure balloons Tru Dilation, Atlas Gold, and Dorado (C.R. Bard, Murray Hill, NJ) were used to determine which valves could be fractured and at what pressure fracture occurred. Mitroflow, Magna, Magna Ease, Mosaic, and Biocor Epic surgical valves were successfully fractured using high-pressures balloon 1 mm larger than the labeled valve size whereas Trifecta and Hancock II surgical valves could not be fractured. Only the internal valve frame was fractured, and the sewing cuff was never disrupted. Manufacturer's rated burst pressures for balloons were exceeded, with fracture pressures ranging from 8 to 24 atmospheres depending on the surgical valve. Testing further demonstrated that fracture facilitated the expansion of previously constrained, underexpanded transcatheter valves (both balloon and self-expanding) to the manufacturer's recommended size. Bench testing demonstrates that the frame of most, but not all, bioprosthetic surgical aortic valves can be fractured using high-pressure balloons. The safety of bioprosthetic valve fracture to optimize valve-in-valve transcatheter aortic valve replacement in small surgical valves requires further clinical investigation. Copyright © 2017 The Society of Thoracic Surgeons. Published by Elsevier Inc. All rights reserved.

  5. Device for two-stage cementing of casing

    Energy Technology Data Exchange (ETDEWEB)

    Kudimov, D A; Goncharevskiy, Ye N; Luneva, L G; Shchelochkov, S N; Shil' nikova, L N; Tereshchenko, V G; Vasiliev, V A; Volkova, V V; Zhdokov, K I

    1981-01-01

    A device is claimed for two-stage cementing of casing. It consists of a body with lateral plugging vents, upper and lower movable sleeves, a check valve with axial channels that's situated in the lower sleeve, and a displacement limiting device for the lower sleeve. To improve the cementing process of the casing by preventing overflow of cementing fluids from the annular space into the first stage casing, the limiter is equipped with a spring rod that is capable of covering the axial channels of the check valve while it's in an operating mode. In addition, the rod in the upper part is equipped with a reinforced area under the axial channels of the check valve.

  6. Regulatory standpoints on the design-basis capability of safety-related motor-operated valves(MOVs) and power-operated gate valves(POGVs)

    International Nuclear Information System (INIS)

    Kim, W. T.; Kum, O. H.

    1999-01-01

    The weakness in the design-basis capability of Motor-Operated Valves(MOVs) and the susceptibility to Pressure Locking and Thermal Binding phenomena of Power-Operated Gate Valves(POGVs) have been major concerns to be resolved in the nuclear society in and abroad since Three Mile Island accident occurred in the USA in 1979. Through detailed analysis of operating experience and regulatory activities, some MOVs and POGVs have been found to be unreliable in performing their safety functions when they are required to do so under certain conditions, especially under design-basis accident conditions. Further, it is well understood that these safety problems may not be identified by the typical valve in-service testing(IST). USNRC has published three Generic Letters, GL 89-10, GL 95-07, and GL 96-05, requiring nuclear plant licensees to take appropriate actions to resolve the problems mentioned above. Korean nuclear regulatory body has made public an administration measure called 'Regulatory recommendation to verify safety functions of the safety-related MOVs and POGVs' on June 13, 1997, and in this administration measure Korean utility is asked to submit written documents to show how it assure design-basis capability of these valves. The following are among the major concerns being considered from a regulation standpoint. Program scope and implementation priority, dynamic tests under differential pressure conditions, accuracy of diagnostic equipment, torque switch setting and torque bypass percentage, weak link analysis, motor actuator sizing, corrective actions taken to resolve pressure locking and thermal binding susceptibility, and a periodic verification program for the valves once design-basis capability has been verified

  7. Bypass valve and coolant flow controls for optimum temperatures in waste heat recovery systems

    Science.gov (United States)

    Meisner, Gregory P

    2013-10-08

    Implementing an optimized waste heat recovery system includes calculating a temperature and a rate of change in temperature of a heat exchanger of a waste heat recovery system, and predicting a temperature and a rate of change in temperature of a material flowing through a channel of the waste heat recovery system. Upon determining the rate of change in the temperature of the material is predicted to be higher than the rate of change in the temperature of the heat exchanger, the optimized waste heat recovery system calculates a valve position and timing for the channel that is configurable for achieving a rate of material flow that is determined to produce and maintain a defined threshold temperature of the heat exchanger, and actuates the valve according to the calculated valve position and calculated timing.

  8. A Solar Energy Powered Autonomous Wireless Actuator Node for Irrigation Systems

    Directory of Open Access Journals (Sweden)

    Rafael Lajara

    2010-12-01

    Full Text Available The design of a fully autonomous and wireless actuator node (“wEcoValve mote” based on the IEEE 802.15.4 standard is presented. The system allows remote control (open/close of a 3-lead magnetic latch solenoid, commonly used in drip irrigation systems in applications such as agricultural areas, greenhouses, gardens, etc. The very low power consumption of the system in conjunction with the low power consumption of the valve, only when switching positions, allows the system to be solar powered, thus eliminating the need of wires and facilitating its deployment. By using supercapacitors recharged from a specifically designed solar power module, the need to replace batteries is also eliminated and the system is completely autonomous and maintenance free. The “wEcoValve mote” firmware is based on a synchronous protocol that allows a bidirectional communication with a latency optimized for real-time work, with a synchronization time between nodes of 4 s, thus achieving a power consumption average of 2.9 mW.

  9. Experimental Qualification of the Sleeved Pin Multilink Attachment for Divertor PFC's

    International Nuclear Information System (INIS)

    Poutanen, J.; McCallum, A.; Turner, A.; Merola, M.

    2006-01-01

    The latest design for connecting the limited life ITER divertor plasma facing components (PFC's) to the reusable cassette body is the so called sleeved pin multilink attachment. The connection is made by expanding a 43 mm diameter hollow AlBr pin inside the fixation holes of components of the cassette body and PFC by a swaging process. The multilink is an easy, safe and fast assembly method, but the original dismantling method of drilling out the pin was found troublesome. Therefore, in the latest attachment design a thin sleeve is incorporated between the pin and the holes, which makes it possible to dismantle the joint by simply pulling out the pin and sleeve sequentially. Experimental qualification of the new sleeved design is now proceeding. The aim of the experimental qualification is to prove that the sleeved design meets the requirements of load carrying capability, clearance free connection, and easy and safe removal. Associated analytical studies were performed to develop and verify theoretical models and correlations for use in design. Results from the experimental qualification will provide reference information for developing tools for making and removing the connection. Theoretical finite element models in association with the results of earlier test campaigns with nonsleeved design were used to determine pin expansion parameters. The expansion parameters were verified with plate-pin tests measuring contact pressures produced by pin expansion. The plate-pin tests were also used to demonstrate the feasibility of pin removal and develop pin removal methodology. The mechanical capabilities of the connection design are being examined with test series of cyclic tensile loading plus articulation-induced loading of a single connection mock-up. Remaking properties of the attachment are being studied with multiple swaging and removing of the pin into the fixation holes. Finally the dismantling of the connection will be examined with full length pin extraction

  10. Microfabricated sleeve devices for chemical reactions

    Science.gov (United States)

    Northrup, M. Allen

    2003-01-01

    A silicon-based sleeve type chemical reaction chamber that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and non-silicon based materials to provide the thermal properties desired. For example, the chamber may combine a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis.

  11. Control of spool position of on/off solenoid operated hydraulic valve by sliding-mode controller

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jae Hak; Hong, Hyun Wook; Park, Myeong Kwan [Pusan National University, Busan (Korea, Republic of); Yun, Young Won [KHPS, Busan (Korea, Republic of)

    2015-11-15

    The use of on/off solenoid operated hydraulic valves instead of proportional valves has been attracting the interest of many researchers and engineers. However, there exist difficulties in controlling the on/off valve because of highly nonlinear characteristics including hysteresis and saturation. This paper considers the application of on/off solenoid operated hydraulic valves to control position of a hydraulic cylinder with the aim of evaluating, feasibility and practicability of their implementation and understanding the potential benefits when they are used in existing hydraulic systems. Assuming that only the current is measured, a sliding mode observer is designed to estimate the spool position and velocity. To alleviate the aforementioned difficulties in controlling the spool position, a nonlinear observer-based controller of an on/off solenoid valve is designed, taking into account the estimated values, based on a nonlinear model including hysteresis and saturation. The control objective is to track a desired spool trajectory. Simulation and experimental results illustrate the efficiency of the designed controller. The proposed controller is validated again in a single-rod hydraulic actuator. Experimental results show that the fluid flow through the valve orifice by controlling the spool position was successfully controlled.

  12. FAILURE MODE AND EFFECT ANALYSIS (FMEA OF BUTTERFLY VALVE IN OIL AND GAS INDUSTRY

    Directory of Open Access Journals (Sweden)

    MUHAMMAD AMIRUL BIN YUSOF

    2016-04-01

    Full Text Available Butterfly valves are mostly used in various industries such as oil and gas plant. This valve operates with rotating motion using pneumatic system. Rotating actuator turns the disc either parallel or perpendicular to the flow. When the valve is fully open, the disc is rotated a quarter turn so that it allows free passage of the fluid and when fully closed, the disc rotated a quarter turns to block the fluid. The primary failure modes for valves are the valve leaks to environment through flanges, seals on the valve body, valve stem packing not properly protected, over tightened packing nuts, the valve cracks and leaks over the seat. To identify the failure of valve Failure Mode and Effects Analysis has been chosen. FMEA is the one of technique to perform failure analysis. It involves reviewing as many components to identify failure modes, and their causes and effects. For each component, the failure modes and their resulting effects on the rest of the system are recorded in a specific FMEA form. Risk priority number, severity, detection, occurrence are the factor determined in this studies. Risk priority number helps to find out the highest hazardous activities which need more attention than the other activity. The highest score of risk priority number in this research is seat. Action plan was proposed to reduce the risk priority number and so that potential failures also will be reduced.

  13. Design optimization of a novel pMDI actuator for systemic drug delivery.

    Science.gov (United States)

    Kakade, Prashant P; Versteeg, Henk K; Hargrave, Graham K; Genova, Perry; Williams Iii, Robert C; Deaton, Daniel

    2007-01-01

    Pressurized metered dose inhalers (pMDIs) are the most widely prescribed and economical respiratory drug delivery systems. Conventional pMDI actuators-those based on "two-orifice-and-sump" designs-produce an aerosol with a reasonable respirable fraction, but with high aerosol velocity. The latter is responsible for high oropharyngeal deposition, and consequently low drug delivery efficiency. Kos' pMDI technology is based on a proprietary vortex nozzle actuator (VNA), an innovative actuator configuration that seeks to reduce aerosol plume velocity, thereby promoting deep lung deposition. Using VNA development as a case study, this paper presents a systematic design optimization process to improve the actuator performance through use of advanced optical characterization tools. The optimization effort mainly relied on laser-based optical diagnostics to provide an improved understanding of the fundamentals of aerosol formation and interplay of various geometrical factors. The performance of the optimized VNA design thus evolved was characterized using phase Doppler anemometry and cascade impaction. The aerosol velocities for both standard and optimized VNA designs were found to be comparable, with both notably less than conventional actuators. The optimized VNA design also significantly reduces drug deposition in the actuator as well as USP throat adapter, which in turn, leads to a significantly higher fine particle fraction than the standard design (78 +/- 3% vs. 63 +/- 2% on an ex valve basis). This improved drug delivery efficiency makes VNA technology a practical proposition as a systemic drug delivery platform. Thus, this paper demonstrates how advanced optical diagnostic and characterization tools can be used in the development of high efficiency aerosol drug delivery devices.

  14. Analgesic Effect of Intraperitoneal Bupivacaine Hydrochloride After Laparoscopic Sleeve Gastrectomy: a Randomized Clinical Trial.

    Science.gov (United States)

    Alamdari, Nasser Malekpour; Bakhtiyari, Mahmood; Gholizadeh, Barmak; Shariati, Catrine

    2018-03-01

    The indications for sleeve gastrectomy as a primary procedure for the surgical treatment of morbid obesity have increased worldwide. Pain is the most common complaint for patients on the first day after laparoscopic sleeve gastrectomy. There are various methods for decreasing pain after laparoscopic sleeve gastrectomy such as the use of intraperitoneal bupivacaine hydrochloride. This clinical trial was an attempt to discover the effects of intraperitoneal bupivacaine hydrochloride on alleviating postoperative pain after laparoscopic sleeve gastrectomy. In general, 120 patients meeting the inclusion criteria were enrolled. Patients were randomly allocated into two interventions and control groups using a balanced block randomization technique. One group received intraperitoneal bupivacaine hydrochloride (30 cm 3 ), and the other group served as the control one and did not receive bupivacaine hydrochloride. Diclofenac suppository and paracetamol injection were administered to both groups for postoperative pain management. The mean subjective postoperative pain score was significantly decreased in patients who received intraperitoneal bupivacaine hydrochloride within the first 24 h after the surgery; thus, the instillation of bupivacaine hydrochloride was beneficial in managing postoperative pain. The intraoperative peritoneal irrigation of bupivacaine hydrochloride (30 cm 3 , 0.25%) in sleeve gastrectomy patients was safe and effective in reducing postoperative pain, nausea, and vomiting (IRCT2016120329181N4).

  15. Improvements in valve reliability due to implementation of effective condition monitoring programs

    International Nuclear Information System (INIS)

    Hale, Stan

    2003-01-01

    Modern diagnostic systems for motor-operated valves, pneumatic control valves and checkvalves have facilitated a shift in the maintenance philosophy for valves and actuators in nuclear power plants from schedule based to condition-based maintenance (CBM). This shift enables plant management to focus resources and schedule priority on the plant equipment that warrants attention thereby not wasting resources or increasing the human factors risk on equipment that has not degraded. The most recent initiatives combine condition monitoring with risk/safety insights to focus attention and resonances on the right equipment at the right time consistent with each component's safety-significance. The activities of the ASME working groups responsible for nuclear O and M codes have kept pace with the technology and process improvements necessary to maximize the technical and economic benefits of condition based and risk informed maintenance. This paper discusses adoption of valve condition monitoring in the nuclear power industry, changes to ASME codes and standards during the 90's to facilitate adoption of condition monitoring technology for in-service testing and recent efforts to combine risk insights with condition monitoring strategies to achieve the highest level of valve reliability and nuclear safety without over inflating maintenance cost. (author)

  16. Modelling of coupled self-actuating safety, relief and damped check valve systems with the codes TRAC-PF1 and ROLAST

    International Nuclear Information System (INIS)

    Neumann, U.; Puzalowski, R.; Grimm, I.

    1985-01-01

    Numerical valve models for simulation of selfactuating safety valves and damped check valves are introduced for the computer programs TRAC-PF1 and ROLAST. As examples of application post-test calculations and stability analysis are given. (orig.)

  17. Development of a high speed extrusion concept using a floating screw sleeve for solid-melt-separation

    Science.gov (United States)

    Karrenberg, Gregor; Wortberg, Johannes

    2015-05-01

    The High-Speed-S-Truder with floating screw sleeve is an alternative extrusion concept with solid-melt-separation. A fairly conventional 35 mm screw with a length of 21 D, which is accelerated by a 75 kW gearless, water cooled synchronous drive, conveys the resin into a 60 mm screw sleeve with a length of 10 D. Inside the sleeve the material is plasticizied and discharged into the outer screw channel of the sleeve through radial bores. Only the solid bed remains inside. The development of a melt pool - and thus a decrease of the plasticizing capacity - is avoided. The sleeve is rotated by drag forces only (approximately 10 - 15 % of the screw speed). Due to the low speed of the screw sleeve molten material is conveyed to a 4 D Dynamic Mixing Ring in a gentle manner. The DMRs floating ring and the screw sleeve are directly coupled. The granules in the screw channel are stopped by a barrier on the screw in front of the mixing device. So nearly no unmelted material can pass the system. For temperature management in the plastification and mixing zone a 3-zone heating/air-cooling system is used. Various kinds of experiments with the High-Speed S-Truder were conducted. Reachable throughputs with different types of material (LDPE, LLDPE, PP, PS) have been tested. Also three screw geometries, which are mainly varying in the channel depth, were compared. Experimental results and theoretical background will be described in this paper.

  18. Silicon-based sleeve devices for chemical reactions

    Science.gov (United States)

    Northrup, M. Allen; Mariella, Jr., Raymond P.; Carrano, Anthony V.; Balch, Joseph W.

    1996-01-01

    A silicon-based sleeve type chemical reaction chamber that combines heaters, such as doped polysilicon for heating, and bulk silicon for convection cooling. The reaction chamber combines a critical ratio of silicon and silicon nitride to the volume of material to be heated (e.g., a liquid) in order to provide uniform heating, yet low power requirements. The reaction chamber will also allow the introduction of a secondary tube (e.g., plastic) into the reaction sleeve that contains the reaction mixture thereby alleviating any potential materials incompatibility issues. The reaction chamber may be utilized in any chemical reaction system for synthesis or processing of organic, inorganic, or biochemical reactions, such as the polymerase chain reaction (PCR) and/or other DNA reactions, such as the ligase chain reaction, which are examples of a synthetic, thermal-cycling-based reaction. The reaction chamber may also be used in synthesis instruments, particularly those for DNA amplification and synthesis.

  19. ENDOSCOPIC SLEEVE GASTROPLASTY FOR OBESITY TREATMENT: TWO YEARS OF EXPERIENCE.

    Science.gov (United States)

    Lopez-Nava, Gontrand; Galvão, M P; Bautista-Castaño, I; Fernandez-Corbelle, J P; Trell, M; Lopez, N

    2017-01-01

    Bariatric endoscopic techniques are minimally invasive and induce gastric volume reduction to treat obesity. Aim : To evaluate endoscopic sleeve gastroplasty (Apollo method) using a suturing method directed at the greater curvature, as well as the perioperative care, two year safety and weight loss. Prospective single-center study over 154 patients (108 females) using the endoscopic sleeve gastroplasty procedure under general anesthesia with overnight inpatient observation. Of the154 initial patients, 143 were available for 1-month of follow-up, 133 for 6-month, 64 for 12-month and 28 completed the 24 month assessment. Follow-up was carried out by a multidisciplinary team (nutritionist and psychologist). Outcomes evaluated were: change in BMI; change in body weight (TBWL); % of loss of initial body weight (%TBWL); % of excess body weight loss (%EWL) (segregated in > or 25% %EWL. There were no mayor adverse events intraprocedure or during the 24 months of follow-up . Endoscopic sleeve gastroplasty with regular monitoring by a multidisciplinary team can be considered an effective, safe and well tolerated procedure for obesity treatment, at least for two years of follow-up. As técnicas de endoscopia bariátrica são minimamente invasivas e induzem à redução do volume gástrico para tratar a obesidade. Avaliar a gastroplastia sleeve endoscópica (método Apollo) usando um método de sutura direcionado para a grande curvatura, bem como os cuidados perioperatórios, segurança em dois anos e perda de peso. Estudo prospectivo em um único centro com 154 pacientes (108 mulheres) usando o procedimento endoscópico de gastroplastia sleeve sob anestesia geral com observação do paciente internado durante a noite. Dos 154 pacientes iniciais, 143 estiveram disponíveis para acompanhamento de um mês, 133 durante seis meses, 64 durante 12 meses e 28 completaram a avaliação de 24 meses. O acompanhamento foi realizado por equipe multidisciplinar (nutricionista e psic

  20. Parameter design and performance analysis of shift actuator for a two-speed automatic mechanical transmission for pure electric vehicles

    Directory of Open Access Journals (Sweden)

    Jianjun Hu

    2016-08-01

    Full Text Available Recent developments of pure electric vehicles have shown that pure electric vehicles equipped with two-speed or multi-speed gearbox possess higher energy efficiency by ensuring the drive motor operates at its peak performance range. This article presents the design, analysis, and control of a two-speed automatic mechanical transmission for pure electric vehicles. The shift actuator is based on a motor-controlled camshaft where a special geometric groove is machined, and the camshaft realizes the axial positions of the synchronizer sleeve for gear engaging, disengaging, and speed control of the drive motor. Based on the force analysis of shift process, the parameters of shift actuator and shift motor are designed. The drive motor’s torque control strategy before shifting, speed governing control strategy before engaging, shift actuator’s control strategy during gear engaging, and drive motor’s torque recovery strategy after shift process are proposed and implemented with a prototype. To validate the performance of the two-speed gearbox, a test bed was developed based on dSPACE that emulates various operation conditions. The experimental results indicate that the shift process with the proposed shift actuator and control strategy could be accomplished within 1 s under various operation conditions, with shift smoothness up to passenger car standard.

  1. 'Stent in a stent'--an alternative technique for removing partially covered stents following sleeve gastrectomy complications.

    Science.gov (United States)

    Vasilikostas, Georgios; Sanmugalingam, Nimalan; Khan, Omar; Reddy, Marcus; Groves, Chris; Wan, Andrew

    2014-03-01

    Endoscopic stenting is a relatively new technique for the treatment of post sleeve gastrectomy complications. Partially covered stents are used in this method to minimise the risk of migration but they are associated with difficulties with removal. Patients requiring emergency stenting following sleeve gastrectomy underwent insertion of a partially covered metallic stent. One month later, if the stent was not easily removable, a fully covered overlapping stent was inserted and the patient was readmitted 2 weeks later for removal of both stents. Four patients required stenting following sleeve gastrectomy leaks, and one patient required stenting for a stricture. In these cases, a 'stent in a stent' technique was used for removal. This technique allows the safe removal of partially covered stents inserted following sleeve gastrectomy complications.

  2. Method for driving an actuator, actuator drive, and apparatus comprising an actuator

    OpenAIRE

    2010-01-01

    An actuator driver circuit includes a drive signal source and an electrical damping element having a negative resistance connected in series with the drive signal source. A controllable switch is provided for selectively switching the electrical damping element into or put of a signal path from a drive signal source output to a driver circuit output, in order to selectively change the electrical damping of an actuator. For example, the electrical damping of a radial actuator or a focus actuat...

  3. Bioprosthetic Valve Fracture Improves the Hemodynamic Results of Valve-in-Valve Transcatheter Aortic Valve Replacement.

    Science.gov (United States)

    Chhatriwalla, Adnan K; Allen, Keith B; Saxon, John T; Cohen, David J; Aggarwal, Sanjeev; Hart, Anthony J; Baron, Suzanne J; Dvir, Danny; Borkon, A Michael

    2017-07-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) may be less effective in small surgical valves because of patient/prosthesis mismatch. Bioprosthetic valve fracture (BVF) using a high-pressure balloon can be performed to facilitate VIV TAVR. We report data from 20 consecutive clinical cases in which BVF was successfully performed before or after VIV TAVR by inflation of a high-pressure balloon positioned across the valve ring during rapid ventricular pacing. Hemodynamic measurements and calculation of the valve effective orifice area were performed at baseline, immediately after VIV TAVR, and after BVF. BVF was successfully performed in 20 patients undergoing VIV TAVR with balloon-expandable (n=8) or self-expanding (n=12) transcatheter valves in Mitroflow, Carpentier-Edwards Perimount, Magna and Magna Ease, Biocor Epic and Biocor Epic Supra, and Mosaic surgical valves. Successful fracture was noted fluoroscopically when the waist of the balloon released and by a sudden drop in inflation pressure, often accompanied by an audible snap. BVF resulted in a reduction in the mean transvalvular gradient (from 20.5±7.4 to 6.7±3.7 mm Hg, P valve effective orifice area (from 1.0±0.4 to 1.8±0.6 cm 2 , P valves to facilitate VIV TAVR with either balloon-expandable or self-expanding transcatheter valves and results in reduced residual transvalvular gradients and increased valve effective orifice area. © 2017 American Heart Association, Inc.

  4. Design and characterization of poly(dimethylsiloxane)-based valves for interfacing continuous-flow sampling to microchip electrophoresis.

    Science.gov (United States)

    Li, Michelle W; Huynh, Bryan H; Hulvey, Matthew K; Lunte, Susan M; Martin, R Scott

    2006-02-15

    This work describes the fabrication and evaluation of a poly(dimethyl)siloxane (PDMS)-based device that enables the discrete injection of a sample plug from a continuous-flow stream into a microchannel for subsequent analysis by electrophoresis. Devices were fabricated by aligning valving and flow channel layers followed by plasma sealing the combined layers onto a glass plate that contained fittings for the introduction of liquid sample and nitrogen gas. The design incorporates a reduced-volume pneumatic valve that actuates (on the order of hundreds of milliseconds) to allow analyte from a continuously flowing sampling channel to be injected into a separation channel for electrophoresis. The injector design was optimized to include a pushback channel to flush away stagnant sample associated with the injector dead volume. The effect of the valve actuation time, the pushback voltage, and the sampling stream flow rate on the performance of the device was characterized. Using the optimized design and an injection frequency of 0.64 Hz showed that the injection process is reproducible (RSD of 1.77%, n = 15). Concentration change experiments using fluorescein as the analyte showed that the device could achieve a lag time as small as 14 s. Finally, to demonstrate the potential uses of this device, the microchip was coupled to a microdialysis probe to monitor a concentration change and sample a fluorescein dye mixture.

  5. Study on grout-filled coupling steel sleeve; Kokan sleeve wo mochiita grout jutenshiki tekkin tsugite ni kansuru kenkyu

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, Y. [Osaka University, Osaka (Japan)

    1997-06-01

    Newly designed grout-filled coupling sleeve is discussed, which uses as the sleeve an electric resistance welded tube with protrusions formed in a checker pattern on its inner wall and is capable of using various premixed grouting materials available on the market. Specimens are subjected to uniaxial tensile loading and positive/negative cyclic loading, and the impact of various factors on the basic performance of the specimens and their stress/distortion characteristics at local spots in the reinforcing bar are disclosed. In the positive/negative cyclic loading in the plastic region, however, such findings are not obtained. In view of the stress/distortion characteristics at local spots in the reinforcing bar, a method is proposed for estimating the coupling strength and fracture type. A method for estimating the deformation behavior of the coupling, however, is not proposed. Investigations are conducted into the manufacture and installation of the grout holding framework, coupling fixing jigs, plugs, etc., and it is found that precasting should be studied in the future. 38 refs., 156 figs., 30 tabs.

  6. Sleeve gastrectomy effects on hunger, satiation, and gastrointestinal hormone and motility responses after a liquid meal test.

    Science.gov (United States)

    Mans, Esther; Serra-Prat, Mateu; Palomera, Elisabet; Suñol, Xavier; Clavé, Pere

    2015-09-01

    The relation between hunger, satiation, and integrated gastrointestinal motility and hormonal responses in morbidly obese patients after sleeve gastrectomy has not been determined. The objective was to assess the effects of sleeve gastrectomy on hunger, satiation, gastric and gallbladder motility, and gastrointestinal hormone response after a liquid meal test. Three groups were studied: morbidly obese patients (n = 16), morbidly obese patients who had had sleeve gastrectomy (n = 8), and nonobese patients (n = 16). The participants fasted for 10 h and then consumed a 200-mL liquid meal (400 kcal + 1.5 g paracetamol). Fasting and postprandial hunger, satiation, hormone concentrations, and gastric and gallbladder emptying were measured several times over 4 h. No differences were observed in hunger and satiation curves between morbidly obese and nonobese groups; however, sleeve gastrectomy patients were less hungry and more satiated than the other groups. Antrum area during fasting in morbidly obese patients was statistically significant larger than in the nonobese and sleeve gastrectomy groups. Gastric emptying was accelerated in the sleeve gastrectomy group compared with the other 2 groups (which had very similar results). Gallbladder emptying was similar in the 3 groups. Sleeve gastrectomy patients showed the lowest ghrelin concentrations and higher early postprandial cholecystokinin and glucagon-like peptide 1 peaks than did the other participants. This group also showed an improved insulin resistance pattern compared with morbidly obese patients. Sleeve gastrectomy seems to be associated with profound changes in gastrointestinal physiology that contribute to reducing hunger and increasing sensations of satiation. These changes include accelerated gastric emptying, enhanced postprandial cholecystokinin and glucagon-like peptide 1 concentrations, and reduced ghrelin release, which together may help patients lose weight and improve their glucose metabolism after

  7. The static actuation of dielectric elastomer actuators: how does pre-stretch improve actuation?

    International Nuclear Information System (INIS)

    Kofod, Guggi

    2008-01-01

    It has previously been shown that providing dielectric elastomer actuators with a level of pre-stretch can improve properties such as breakdown strength, actuation strain and efficiency. The actuation in such actuators depends on an interplay between the highly nonlinear hyperelastic stress-strain behaviour with the electrostatic Maxwell's stress; however, the direct effects of pre-stretch on the electromechanical coupling have still not been investigated in detail. We compare several experimental results found in the literature on the hyperelastic parameters of the Ogden model for the commonly used material VHB 4910, and introduce a more detailed and thus more accurate fit to a previous uniaxial stress-strain experiment. Electrostatic actuation models for a pure shear cuboid dielectric elastomer actuator with pre-stretch are introduced, for both intensive and extensive variables. For both intensive and extensive variables the constant strain (blocked stress or force) as well as the actuation strain is presented. It is shown how in the particular case of isotropic amorphous elastomers the pre-stretch does not affect the electromechanical coupling directly, and that the enhancement in actuation strain due to pre-stretch occurs through the alteration of the geometrical dimensions of the actuator. Also, the presence of the optimum load is explained as being due to the plateau region in the force-stretch curve, and it is shown that pre-stretch is not able to affect its position. Finally, it is shown how the simplified Ogden fit leads to entirely different conclusions for actuation strain in terms of extensive variables as does the detailed fit, emphasizing the importance of employing accurate hyperelastic models for the stress-stretch behaviour of the elastomer.

  8. Development of Long-Lifetime Pulsed Gas Valves for Pulsed Electric Thrusters

    Science.gov (United States)

    Burkhardt, Wendel M.; Crapuchettes, John M.; Addona, Brad M.; Polzin, Kurt A.

    2015-01-01

    It is advantageous for gas-fed pulsed electric thrusters to employ pulsed valves so propellant is only flowing to the device during operation. The propellant utilization of the thruster will be maximized when all the gas injected into the thruster is acted upon by the fields produced by the electrical pulse. Gas that is injected too early will diffuse away from the thruster before the electrical pulse can act to accelerate the propellant. Gas that is injected too late will miss being accelerated by the already-completed electrical pulse. As a consequence, the valve must open quickly and close equally quickly, only remaining open for a short duration. In addition, the valve must have only a small amount of volume between the sealing body and the thruster so the front and back ends of the pulse are as coincident as possible with the valve cycling, with very little latent propellant remaining in the feed lines after the valve is closed. For a real mission of interest, a pulsed thruster can be expected to pulse at least 10(exp 10) - 10(exp 11) times, setting the range for the number of times a valve must open and close. The valves described in this paper have been fabricated and tested for operation in an inductive pulsed plasma thruster (IPPT) for in-space propulsion. In general, an IPPT is an electrodeless space propulsion device where a capacitor is charged to an initial voltage and then discharged, producing a high-current pulse through a coil. The field produced by this pulse ionizes propellant, inductively driving current in a plasma located near the face of the coil. Once the plasma is formed, it can be accelerated and expelled at a high exhaust velocity by the electromagnetic Lorentz body force arising from the interaction of the induced plasma current and the magnetic field produced by the current in the coil. The valve characteristics needed for the IPPT application require a fast-acting valve capable of a minimum of 10(exp 10) valve actuation cycles. Since

  9. A Method for Aileron Actuator Fault Diagnosis Based on PCA and PGC-SVM

    Directory of Open Access Journals (Sweden)

    Wei-Li Qin

    2016-01-01

    Full Text Available Aileron actuators are pivotal components for aircraft flight control system. Thus, the fault diagnosis of aileron actuators is vital in the enhancement of the reliability and fault tolerant capability. This paper presents an aileron actuator fault diagnosis approach combining principal component analysis (PCA, grid search (GS, 10-fold cross validation (CV, and one-versus-one support vector machine (SVM. This method is referred to as PGC-SVM and utilizes the direct drive valve input, force motor current, and displacement feedback signal to realize fault detection and location. First, several common faults of aileron actuators, which include force motor coil break, sensor coil break, cylinder leakage, and amplifier gain reduction, are extracted from the fault quadrantal diagram; the corresponding fault mechanisms are analyzed. Second, the data feature extraction is performed with dimension reduction using PCA. Finally, the GS and CV algorithms are employed to train a one-versus-one SVM for fault classification, thus obtaining the optimal model parameters and assuring the generalization of the trained SVM, respectively. To verify the effectiveness of the proposed approach, four types of faults are introduced into the simulation model established by AMESim and Simulink. The results demonstrate its desirable diagnostic performance which outperforms that of the traditional SVM by comparison.

  10. Preoperative endoscopy may reduce the need for revisional surgery for gastro-oesophageal reflux disease following laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Madhok, B M; Carr, W R J; McCormack, C; Boyle, M; Jennings, N; Schroeder, N; Balupuri, S; Small, P K

    2016-08-01

    Laparoscopic sleeve gastrectomy is a safe and effective bariatric operation, but postoperative reflux symptoms can sometimes necessitate revisional surgery. Roux-en-Y gastric bypass is the preferred operation in morbidly obese patients with gastro-oesophageal reflux disease. In 2011, we introduced preoperative endoscopy to assess for hiatus hernia or evidence of oesophagitis in conjunction with an assessment of gastro-oesophageal reflux symptoms for all patients undergoing bariatric surgery with a view to avoid sleeve gastrectomy for these patients. A prospectively maintained database was used to identify patients who underwent sleeve gastrectomy before and after we changed the unit policy. The need for revisional surgery in patients with troublesome gastro-oesophageal reflux disease was examined. Prior to 2011, 130 patients underwent sleeve gastrectomy, and 11 (8.5%) of them required conversion to Roux-en-Y gastric bypass for symptomatic reflux disease. Following the policy change, 284 patients underwent sleeve gastrectomy, and to date, only five (1.8%) have required revisional surgery (p = 0.001). Baseline demographics were comparable between the groups, and average follow-up period was 47 and 33 months, respectively, for each group. Preoperative endoscopy and a detailed clinical history regarding gastro-oesophageal reflux symptoms may improve patient selection for sleeve gastrectomy. Avoiding sleeve gastrectomy in patients with reflux disease and/or hiatus hernia may reduce the incidence of revisional surgery. © 2016 World Obesity.

  11. Elastic Knee Sleeves Limit Anterior Tibial Translation in Healthy Females

    Directory of Open Access Journals (Sweden)

    Robert Csapo, Simona Hosp, Ramona Folie, Robert Eberle, Michael Hasler, Werner Nachbauer

    2016-03-01

    Full Text Available Knee sleeves or braces represent auxiliary tools that have repeatedly been used by athletes, in an attempt to increase knee stability and, thus, reduce the risk of (recurrent ligamentous injuries. Since ACL injuries typically occur in situations involving either torsion or hyperextension of the knee, it has been speculated that braces might protect the ACL by countering excessive anterior translation of the tibia with respect to the femur (Beynnon et al., 1997. However, the preponderance of in vivo studies to test this hypothesis was performed in cohorts of patients suffering from existent ligamentous (Branch et al., 1988; Colville et al., 1986 or other knee injury (Beynnon et al., 1997; Fleming et al., 2000. This complicates the extrapolation of results to healthy subjects. Further, the braces used in these studies were mostly rigid constructs that consisted of either uni- or bilateral hinged bars (Rishiraj et al., 2009. Such braces might hinder performance (Veldhuizen et al., 1991 and would be rejected by the vast majority of healthy athletes. For these reasons, we would like to use this letter to the editor to report the results of our experiments investigating whether a relatively light elastic knee sleeve would limit the degree of anterior tibial translation in computerized arthrometry tests as performed in a sample of non-injured subjects. We recruited ten female college students (age: 23.4 ± 3.2 yrs, height: 1.68 ± 0.05 m, mass: 59.9 ± 5.5 kg who were free of acute or previous injury or any form of orthopaedic disease of the knee joints. The anterior displacement of the tibia was measured using the GNRB® computerized arthrometer (GeNouRob, Laval, France. With subjects lying in the supine position, the lower leg was firmly fixed with plastic caps mounted over the ankle joint and patella. An electrical pressure pad then exerted increasing pressure of up to 250 N on the calf, while a motion sensor, which was positioned on the ventral

  12. Chained Iron Microparticles for Directionally Controlled Actuation of Soft Robots.

    Science.gov (United States)

    Schmauch, Marissa M; Mishra, Sumeet R; Evans, Benjamin A; Velev, Orlin D; Tracy, Joseph B

    2017-04-05

    Magnetic field-directed self-assembly of magnetic particles in chains is useful for developing directionally responsive materials for applications in soft robotics. Using materials with greater complexity allows advanced functions, while still using simple device architectures. Elastomer films containing chained magnetic microparticles were prepared through solvent casting and formed into magnetically actuated lifters, accordions, valves, and pumps. Chaining both enhances actuation and imparts a directional response. Cantilevers used as lifters were able to lift up to 50 times the mass of the polymer film. We introduce the "specific torque", the torque per field per mass of magnetic particles, as a figure of merit for assessing and comparing the performance of lifters and related devices. Devices in this work generated specific torques of 68 Nm/kgT, which is significantly higher than in previously reported actuators. Applying magnetic fields to folded accordion structures caused extension and compression, depending on the accordion's orientation. In peristaltic pumps comprised of composite tubes containing embedded chains, magnetic fields caused a section of the tube to pinch closed where the field was applied. These results will facilitate both the further development of soft robots based on chained magnetic particles and efforts to engineer materials with higher specific torque.

  13. Intraoperative leak testing has no correlation with leak after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Sethi, Monica; Zagzag, Jonathan; Patel, Karan; Magrath, Melissa; Somoza, Eduardo; Parikh, Manish S; Saunders, John K; Ude-Welcome, Aku; Schwack, Bradley F; Kurian, Marina S; Fielding, George A; Ren-Fielding, Christine J

    2016-03-01

    Staple line leak is a serious complication of sleeve gastrectomy. Intraoperative methylene blue and air leak tests are routinely used to evaluate for leak; however, the utility of these tests is controversial. We hypothesize that the practice of routine intraoperative leak testing is unnecessary during sleeve gastrectomy. A retrospective cohort study was designed using a prospectively collected database of seven bariatric surgeons from two institutions. All patients who underwent sleeve gastrectomy from March 2012 to November 2014 were included. The performance of intraoperative leak testing and the type of test (air or methylene blue) were based on surgeon preference. Data obtained included BMI, demographics, comorbidity, presence of intraoperative leak test, result of test, and type of test. The primary outcome was leak rate between the leak test (LT) and no leak test (NLT) groups. SAS version 9.4 was used for univariate and multivariate analyses. A total of 1550 sleeve gastrectomies were included; most were laparoscopic (99.8%), except for one converted and two open cases. Routine intraoperative leak tests were performed in 1329 (85.7%) cases, while 221 (14.3%) did not have LTs. Of the 1329 cases with LTs, there were no positive intraoperative results. Fifteen (1%) patients developed leaks, with no difference in leak rate between the LT and NLT groups (1 vs. 1%, p = 0.999). After adjusting for baseline differences between the groups with a propensity analysis, the observed lack of association between leak and intraoperative leak test remained. In this cohort, leaks presented at a mean of 17.3 days postoperatively (range 1-67 days). Two patients with staple line leaks underwent repeat intraoperative leak testing at leak presentation, and the tests remained negative. Intraoperative leak testing has no correlation with leak due to laparoscopic sleeve gastrectomy and is not predictive of the later development of staple line leak.

  14. Analysis of the Impact of Early Exhaust Valve Opening and Cylinder Deactivation on Aftertreatment Thermal Management and Efficiency for Compression Ignition Engines

    OpenAIRE

    Roberts, Leighton Edward

    2014-01-01

    In order to meet strict emissions regulations, engine manufacturers have implemented aftertreatment technologies which reduce the tailpipe emissions from diesel engines. The effectiveness of most of these systems is limited when exhaust temperatures are low (usually below 200°C to 250°C). This is a problem for extended low load operation, such as idling and during cold start. Use of variable valve actuation, including early exhaust valve opening (EEVO) and cylinder deactivation (CDA), has bee...

  15. Activation of Actuating Hydrogels with WS2 Nanosheets for Biomimetic Cellular Structures and Steerable Prompt Deformation.

    Science.gov (United States)

    Zong, Lu; Li, Xiankai; Han, Xiangsheng; Lv, Lili; Li, Mingjie; You, Jun; Wu, Xiaochen; Li, Chaoxu

    2017-09-20

    Macroscopic soft actuation is intrinsic to living organisms in nature, including slow deformation (e.g., contraction, bending, twisting, and curling) of plants motivated by microscopic swelling and shrinking of cells, and rapid motion of animals (e.g., deformation of jellyfish) motivated by cooperative nanoscale movement of motor proteins. These actuation behaviors, with an exceptional combination of tunable speed and programmable deformation direction, inspire us to design artificial soft actuators for broad applications in artificial muscles, nanofabrication, chemical valves, microlenses, soft robotics, etc. However, so far artificial soft actuators have been typically produced on the basis of poly(N-isopropylacrylamide) (PNiPAM), whose deformation is motived by volumetric shrinkage and swelling in analogue to plant cells, and exhibits sluggish actuation kinetics. In this study, alginate-exfoliated WS 2 nanosheets were incorporated into ice-template-polymerized PNiPAM hydrogels with the cellular microstructures which mimic plant cells, yet the prompt steerable actuation of animals. Because of the nanosheet-reinforced pore walls formed in situ in freezing polymerization and reasonable hierarchical water channels, this cellular hybrid hydrogel achieves super deformation speed (on the order of magnitude of 10° s), controllable deformation direction, and high near-infrared light responsiveness, offering an unprecedented platform of artificial muscles for various soft robotics and devices (e.g., rotator, microvalve, aquatic swimmer, and water-lifting filter).

  16. Design improvement for partial penetration welds of Pressurizer heater sleeves to head junctures

    International Nuclear Information System (INIS)

    Kim, Jin-Seon; Lee, Kyoung-Jin; Park, Tae-Jung; Kim, Moo-Yong

    2007-01-01

    ASME Code, Section III allows partial penetration welds for openings for instrumentation on which there are substantially no piping reactions and requires to have interference fit or limited diametral clearance between nozzles and vessel penetrations for the partial penetration welds. Pressurizer heater sleeves are nonaxisymmetrically attached on the hill-side of bottom head by partial penetration welds. The excessive stresses in the partial penetration weld regions of the heater sleeves are induced by pressure and thermal transient loads and also by the deformation due to manual welding process. The purpose of this study is 1) to improve design for the partial penetration welds between heater sleeves to head junctures, 2) to demonstrate the structural integrity according to the requirements of ASME Code, Section III and 3) to improve welding procedure considering the proposed design

  17. Experimental and numerical studies of various thermal sleeves subjected to severe cyclic thermal shocks

    International Nuclear Information System (INIS)

    Masson, J.C.; Moinereau, D.

    1990-01-01

    During the first operating years of nuclear power plants of different countries, damage was encountered on thermal sleeves used as nozzle protection. Following this discovery studies were initiated to determine the causes and to find solutions. At first a problem of vibration was found and easily solved by reducing gaps and reinforcing the welding of the sleeves. But preliminary tests with cyclic thermal shocks showed a risk of fatigue crack initiation and propagation both in the sleeve fixation and in the nozzle. Therefore a large research and development program was led principally by EDF laboratories of Les Renardieres, to demonstrate the absence of nocivity of thermal shocks during the plants life time [fr

  18. Computed tomography of cystic nerve root sleeve dilatation.

    Science.gov (United States)

    Neave, V C; Wycoff, R R

    1983-10-01

    A case of cystic nerve root sleeve dilatation in the lumbar area associated with a chronic back pain syndrome is presented. Prominent computed tomography (CT) findings include: (a) rounded masses in the region of the foramina isodense with cerebrospinal fluid in the subarachnoid space; (b) associated asymmetry of epidural fat distribution; (c) enlargement of the neural foramina in axial sections with scalloped erosion of the adjacent posteriolateral vertebral body, pedicle, and pedicular-laminar junction with preservation of cortex and without bony sclerosis or infiltrative appearance; (d) prominent or ectatic dural sac with lack of usual epidural landmarks between the sac and vertebral body; and (e) multilevel abnormalities throughout the entire lumbar region. Myelographic and CT correlations are demonstrated with a review of the literature. A discussion of the various cystic abnormalities involving nerve root sheaths is undertaken in an attempt to clarify the confusing nomenclature applied to nerve root sleeve pathology.

  19. Design Comparison of Autonomous High Voltage Driving System for DEAP Actuator

    DEFF Research Database (Denmark)

    Huang, Lina; Pittini, Riccardo; Zhang, Zhe

    2014-01-01

    As a new type of smart material, the Dielectric Electro Active Polymer (DEAP) is introduced in terms of configuration, working principle and potential applications. The design of an autonomous high voltage driving system for DEAP actuator is investigated. The system configuration and the design...... methodology of a high voltage converter are discussed in detail. Based on the heating valve application, three different high voltage converter solutions have been proposed. The different proposals have been compared in terms of energy loss, volume and cost. Finally, the design selection suggestions...

  20. Retained copper sleeve of cu-T IUCD

    African Journals Online (AJOL)

    Dr Adaji

    Case Report. A 47-year old para 7+1 five alive presented at the. Reproductive Health center for removal of a copper-T intrauterine contraceptive device following a clinical diagnosis of pelvic inflammatory disease. The device was inserted the previous year. After easy removal , it was observed that the copper sleeve on one ...

  1. 3D finite element modeling of in-service sleeve repair welding of gas pipelines

    International Nuclear Information System (INIS)

    Alian, Ahmed R.; Shazly, Mostafa; Megahed, Mohammad M.

    2016-01-01

    The present work investigates the influence of welding sequence and scheme on residual stresses induced during in-service sleeve repair welding of gas pipelines. For this purpose, a 3D thermo-mechanical FE analysis is conducted on an 8″-Schedule-20, API 5L-X65 steel pipe. Two welding sequences for the sleeve-pipe circumferential fillet welds are compared in the present study: sequential welding in which one side of the sleeve is welded first and then the other side is welded by the same welder, and simultaneous welding in which both sides of the sleeve are welded concurrently by two welders. Within the simultaneous welding sequence, four different welding schemes, designed to investigate the influence of the number of welders and welding directions on residual stresses, are investigated. The results show that the sequential welding sequence induces less residual stresses and distortions. Within the simultaneous welding sequence, the back-step welding scheme is found to induce the least average residual stresses as compared to other welding schemes. - Highlights: • We model in-service sleeve repair welding using 3D FE. • Model was validated through comparison with existing experimental results. • The study presents results on the effect of both welding sequence and welding scheme on the resulting residual stresses. • Sequential welding sequence generates lower residual stresses than simultaneous welding sequence. • Back-step welding scheme generates the lowest average residual stresses along the pipe circumference.

  2. Variable valve timing in a homogenous charge compression ignition engine

    Science.gov (United States)

    Lawrence, Keith E.; Faletti, James J.; Funke, Steven J.; Maloney, Ronald P.

    2004-08-03

    The present invention relates generally to the field of homogenous charge compression ignition engines, in which fuel is injected when the cylinder piston is relatively close to the bottom dead center position for its compression stroke. The fuel mixes with air in the cylinder during the compression stroke to create a relatively lean homogeneous mixture that preferably ignites when the piston is relatively close to the top dead center position. However, if the ignition event occurs either earlier or later than desired, lowered performance, engine misfire, or even engine damage, can result. The present invention utilizes internal exhaust gas recirculation and/or compression ratio control to control the timing of ignition events and combustion duration in homogeneous charge compression ignition engines. Thus, at least one electro-hydraulic assist actuator is provided that is capable of mechanically engaging at least one cam actuated intake and/or exhaust valve.

  3. Tough ceramics prolong the life of valves, pumps and well tools; Seig keramikk forlenger livet til ventiler, pumper og broennverktoey

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2004-07-01

    Advanced ceramic materials, developed by Dynamic-Ceramic in the UK, are playing a chief role in improving the efficiency of components of oil and gas plants around the world. Transformation toughened zirconia ceramics are more resistant than metals to wear, corrosion, erosion and heat. On oil installations, they are typically used in the wearing parts of MWD (measuring while drilling) and LWD (logging while drilling) equipment, valve plugs, spindles, cages etc. For example, catalyzer tubes made of wear-resistant Technox(TM) last ten times as long as fire-resisting sleeves that are used for the same purpose.

  4. Shape memory alloy actuated accumulator for ultra-deepwater oil and gas exploration

    Science.gov (United States)

    Patil, Devendra; Song, Gangbing

    2016-04-01

    As offshore oil and gas exploration moves further offshore and into deeper waters to reach hydrocarbon reserves, it is becoming essential for the industry to develop more reliable and efficient hydraulic accumulators to supply pressured hydraulic fluid for various control and actuation operations, such as closing rams of blowout preventers and controlling subsea valves on the seafloor. By utilizing the shape memory effect property of nitinol, which is a type of shape memory alloy (SMA), an innovative SMA actuated hydraulic accumulator prototype has been developed and successfully tested at Smart Materials and Structure Laboratory at the University of Houston. Absence of gas in the developed SMA accumulator prototype makes it immune to hydrostatic head loss caused by water depth and thus reduces the number of accumulators required in deep water operations. Experiments with a feedback control have demonstrated that the proposed SMA actuated accumulator can provide precisely regulated pressurized fluids. Furthermore the potential use of ultracapacitors along with an embedded system to control the electric power supplied to SMA allows this accumulator to be an autonomous device for deployment. The developed SMA accumulator will make deepwater oil extraction systems more compact and cost effective.

  5. NRC Information Notice No. 93-01: Accuracy of motor-operated valve diagnostic equipment manufactured by Liberty Technologies

    International Nuclear Information System (INIS)

    Grimes, B.K.

    1993-01-01

    Most licensees rely on MOV diagnostic equipment to provide information on the thrust delivered by the motor actuator in opening or closing its valve. The various types of MOV diagnostic equipment estimate valve stem thrust using different parameters, such as displacement of the spring pack or strain in the stem, mounting bolts, or yoke. Liberty Technologies has developed MOV diagnostic equipment, referred to as the Valve Operation Test and Evaluation System (VOTES), that estimates the thrust needed to open or close a valve based on strain of the valve yoke. The VOTES equipment derives thrust from yoke strain that has been calibrated to stem thrust using measured diametral strain of the valve stem and nominal engineering material properties. On October 2, 1992, Liberty Technologies notified the NRC that it had determined that two new factors can affect the thrust values obtained with its equipment. Those factors involve (1) the possible use of improper stem material constants and (2) the failure to account for a torque effect when the VOTES equipment is calibrated by measuring strain in the threaded portion of the valve stem. Liberty Technologies provided information on performing manual calculations to address these factors and stated that its new software, Version 2.3, assists in performing corrections to the thrust data

  6. Electromechanical actuation of buckypaper actuator: Material properties and performance relationships

    International Nuclear Information System (INIS)

    Cottinet, P.-J.; Souders, C.; Tsai, S.-Y.; Liang, R.; Wang, B.; Zhang, C.

    2012-01-01

    Carbon nanotubes can be assembled into macroscopic thin film materials called buckypapers. To incorporate buckypaper actuators into engineering systems, it is of high importance to understand their material property-actuation performance relationships in order to model and predict the behavior of these actuators. The electromechanical actuation of macroscopic buckypaper structures and their actuators, including single and multi-walled carbon nanotube buckypapers and aligned single-walled nanotube buckypapers, were analyzed and compared. From the experimental evidence, this Letter discusses the effects of the fundamental material properties, including Young modulus and electrical double layer properties, on actuation performance of the resultant actuators. -- Highlights: ► In this study we identified the figure of merit of the electromechanical conversion. ► Different type of buckypaper was realized and characterized for actuation properties. ► The results demonstrated the potential of Buckypapers/Nafion for actuation

  7. Feasibility and profitability of chain integration by NCPAK on flower sleeves products in European market

    NARCIS (Netherlands)

    Yan, X.

    2008-01-01

    In this report, the author describes that the EU flower sleeve wholesalers are the chain leader of the flower sleeve supply chain from China to the EU market. Their strategy changes can easily put NCpak, in full name, 'Sun Hing Plastic Bag Company', a Hong Kong enterprise based on Shenzhen City,

  8. Transpiring purging access probe for particulate laden or hazardous environments

    Science.gov (United States)

    VanOsdol, John G

    2013-12-03

    An access probe for remote-sensing access through a viewing port, viewing volume, and access port into a vessel. The physical boundary around the viewing volume is partially formed by a porous sleeve lying between the viewing volume and a fluid conduit. In a first mode of operation, a fluid supplied to the fluid conduit encounters the porous sleeve and flows through the porous material to maintain the viewing volume free of ash or other matter. When additional fluid force is needed to clear the viewing volume, the pressure of the fluid flow is increased sufficiently to slidably translate the porous sleeve, greatly increasing the flow into the viewing volume. The porous sleeve is returned to position by an actuating spring. The access probe thereby provides for alternate modes of operation based on the pressure of an actuating fluid.

  9. Design, test and model of a hybrid magnetostrictive hydraulic actuator

    International Nuclear Information System (INIS)

    Chaudhuri, Anirban; Yoo, Jin-Hyeong; Wereley, Norman M

    2009-01-01

    The basic operation of hybrid hydraulic actuators involves high frequency bi-directional operation of an active material that is converted to uni-directional motion of hydraulic fluid using valves. A hybrid actuator was developed using magnetostrictive material Terfenol-D as the driving element and hydraulic oil as the working fluid. Two different lengths of Terfenol-D rod, 51 and 102 mm, with the same diameter, 12.7 mm, were used. Tests with no load and with load were carried out to measure the performance for uni-directional motion of the output piston at different pumping frequencies. The maximum no-load flow rates were 24.8 cm 3 s −1 and 22.7 cm 3 s −1 with the 51 mm and 102 mm long rods respectively, and the peaks were noted around 325 Hz pumping frequency. The blocked force of the actuator was close to 89 N in both cases. A key observation was that, at these high pumping frequencies, the inertial effects of the fluid mass dominate over the viscous effects and the problem becomes unsteady in nature. In this study, we also develop a mathematical model of the hydraulic hybrid actuator in the time domain to show the basic operational principle under varying conditions and to capture phenomena affecting system performance. Governing equations for the pumping piston and output shaft were obtained from force equilibrium considerations, while compressibility of the working fluid was taken into account by incorporating the bulk modulus. Fluid inertia was represented by a lumped parameter approach to the transmission line model, giving rise to strongly coupled ordinary differential equations. The model was then used to calculate the no-load velocities of the actuator at different pumping frequencies and simulation results were compared with experimental data for model validation

  10. A grayscale pneumatic micro-valve for use in a reconfigurable tactile tablet for vision-impaired individuals

    International Nuclear Information System (INIS)

    Schneider, Joseph Devin; Rebolledo-Mendez, Jovan David; McNamara, Shamus

    2015-01-01

    The design, fabrication, and characterization of a strained bilayer film for use in a micro-valve for a reconfigurable tactile tablet for vision-impaired individuals is presented. The bilayer film consists of a compressive and tensile layer to cause the film to coil and retract from the gas channel when the micro-valve is in the open position. A novel support structure that improves yield and controls the direction of coiling is demonstrated. An array of 225 strained bilayer films was designed and fabricated. Each strained bilayer film was able to be actuated individually with a voltage that ranged between 60 and 70 V. The relationship between the applied voltage and the percentage open of the micro-valve is found to be linear over an extended voltage range, enabling the reconfigurable tactile tablet to produce the equivalent of a grayscale image. (paper)

  11. Effects of wearing lower leg compression sleeves on locomotion economy.

    Science.gov (United States)

    Kurz, Eduard; Anders, Christoph

    2018-09-01

    The purpose of this investigation was to assess the effect of compression sleeves on muscle activation cost during locomotion. Twenty-two recreationally active men (age: 25 ± 3 years) ran on a treadmill at four different speeds (ordered sequence of 2.8, 3.3, 2.2, and 3.9 m/s). The tests were performed without (control situation, CON) and while wearing specially designed lower leg compression sleeves (SL). Myoelectric activity of five lower leg muscles (tibialis anterior, fibularis longus, lateral and medial head of gastrocnemius, and soleus) was captured using Surface EMG. To assess muscle activation cost, the cumulative muscle activity per distance travelled (CMAPD) of the CON and SL situations was determined. Repeated measures analyses of variance were performed separately for each muscle. The analyses revealed a reduced lower leg muscle activation cost with respect to test situation for SL for all muscles (p  0.18). The respective significant reductions of CMAPD values during SL ranged between 4% and 16% and were largest at 2.8 m/s. The findings presented point towards an improved muscle activation cost while wearing lower leg compression sleeves during locomotion that have potential to postpone muscle fatigue.

  12. SCC testing of steam generator tubes repaired by welded sleeves

    International Nuclear Information System (INIS)

    Pierson, E.; Stubbe, J.

    1993-01-01

    One way to repair steam generator tubing is to introduce a sleeve inside the tube so that it spans the corroded area and to seal it at both ends. This technique has been studied at Laborelec with a particular attention paid to the occurrence of new SCC cracks at the upper joint. Tube segments coming from the same lot of mill annealed alloy 600 were sent to six manufacturers to be sleeved by their own procedure (including TIG, laser or kinetic welding, followed or not by a stress relief heat treatment), and then tested at Laborelecin 10% NaOH at 350 degrees C. The tests were performed with and without differential pressure i.e. in capsules (Δ = 9 and 19 MPa) and in autoclave (Δp = 0). Nearly all the not stress relieved mock-ups developed through cracks in several hundred hours in auto-clave. The cracks were circumferential and situated near the weld. At 9 and 19 MPa, the time to failure decreased and longitudinal cracks appeared near the weld and at the transition zone of expanded areas. Cracks were never observed in the alloy 690 sleeve, except in the weld bead. Reference capsules (roll expaned tubes) made of the same lot of alloy 600 were tested in the same environment

  13. Laparoscopic Sleeve Gastrectomy versus Laparoscopic Banded Sleeve Gastrectomy: First Prospective Pilot Randomized Study

    Directory of Open Access Journals (Sweden)

    Valeria Tognoni

    2016-01-01

    Full Text Available Introduction. The placement of ring or band around the gastric tube might prevent the dilation after Laparoscopic Sleeve Gastrectomy (LSG. We describe the first randomized study comparing LSG and Laparoscopic Banded Sleeve Gastrectomy (LBSG. Material and Method. Fifty obese patients were enrolled in the study between January 2014 and January 2015. We analysed differences in operative time, complication rate, mortality, and BMI between the two groups over a period of 12 months. Results. Twenty-five patients received LSG (group A and 25 LBSG (group B. The mean preoperative BMI was 47.3±6.58 kg/m2 and 44.95±5.85 kg/m2, respectively, in the two groups. There was no statistical relevant difference in operative time. No intraoperative complications occurred. Mean BMI registered after 3, 6, and 12 months in groups A and B, respectively, were 37.86±5.72 kg/m2 and 37.58±6.21 kg/m2 (p=0.869, 33.64±6.08 kg/m2 and 32.03±5.24 kg/m2 (p=0.325, and 29.72±4.40 kg/m2 and 27.42±4.47 kg/m2 (p=0.186; no statistical relevant difference was registered between the two groups. Conclusion. LBSG is a safe and feasible procedure. The time required for the device positioning did not influence significantly the surgical time. The results of bodyweight loss did not document any statistically significant differences among the two groups, even though LBSG group showed a mean BMI slightly lower than that of the control group.

  14. Actuator with Multi Degrees of Freedom(Actuator)

    OpenAIRE

    矢野, 智昭; Tomoaki, YANO; 産業技術総合研究所

    2006-01-01

    The advantages, problems and the recent developments of the actuator with multi degrees of freedom are presented. At first, the advantages of the actuator with multi degrees of freedom are described. Next, the problems needed to solve for practical use are presented. The recent applications of the actuator with multi degrees of freedom are also reviewed.

  15. Endoscopic sleeve gastroplasty (the Apollo method: a new approach to obesity management

    Directory of Open Access Journals (Sweden)

    Gontrand López-Nava-Breviere

    2016-04-01

    Full Text Available Background: Many obese patients cannot lose weight or reject conventional obesity management. Endoscopic sleeve gastroplasty (the Apollo method is a pioneering coadjuvant, interventionist technique for the integral management of obesity. Objectives: The goals of this study were to report safety and efficacy results obtained at 6 months in patients undergoing endoscopic sleeve gastroplasty. Material and methods: A prospective study was performed in 55 patients (13 males, 42 females who were subjected to the Apollo technique; mean age was 43.5 years (range 25-60 and mean BMI was 37.7 kg/m² (range 30-48. All received multidisciplinary follow-up for weight loss. Weight changes and presence of complications were assessed. Through the endoscope a triangular pattern suture is performed consisting of approximately 3-6 transmural (mucosa to serosa stitches, using a cinch device to bring them nearer and form a plication. Results: A total of 6-8 plications are used to provide a tubular or sleeve-shaped restriction to the gastric cavity. No major complications developed and patients were discharged at 24 hours following the procedure. Endoscopic and radiographic follow-up at 6 months post-procedure showed a well preserved tubular form to the stomach. After 6 months patients had lost 18.9 kg and 55.3% of excess weight. Conclusions: Endoscopic sleeve gastroplasty, together with dietary and psycho-behavioral changes, is a safe, effective technique in the coadjuvant management of obese patients.

  16. Compact, planar, translational piezoelectric bimorph actuator with Archimedes’ spiral actuating tethers

    International Nuclear Information System (INIS)

    Yang, Chenye; Liu, Sanwei; Livermore, Carol; Xie, Xin

    2016-01-01

    The design, analytical modelling, finite element analysis (FEA), and experimental characterization of a microelectromechanical system (MEMS) out-of-plane (vertical) translational piezoelectric lead–zirconate–titanate (PZT) bimorph actuator supported on Archimedes’ spiral tethers are presented. Three types of bimorph actuators with different electrode patterns (with spiral tethers half actuated, fully actuated with uniform polarity, or fully actuated with reversed polarity) are designed and modelled. The two actuators with the highest predicted performance (half actuated and fully actuated with uniform polarity) are implemented and characterized. Both designs are fabricated by commercial processes and are compatible with integration into more complex MEMS systems. Analytical modelling and FEA are used to analyze and predict the actuators’ displacements and blocking forces. Experimental measurements of the deflections and blocking forces of actuators with full uniform actuation and half actuation validate the design. At an applied voltage of 110 V, the out-of-plane deflections of the actuators with half actuation and full uniform actuation are measured at about 17 µ m and 29 µ m respectively, in good agreement with analytical predictions of 17.3 µ m and 34.2 µ m and FEA predictions of 17.1 µ m and 25.8 µ m. The blocking force for devices with half-actuated tethers is predicted to be 12 mN (analytical) and 10 mN (FEA), close to the experimental value of 9 mN. The blocking force for devices with full uniform actuation is predicted to be 23 mN (analytical) and 17 mN (FEA), as compared with 15 mN in experiments. (paper)

  17. Force measurements of a magnetic micro actuator proposed for a microvalve array

    International Nuclear Information System (INIS)

    Chang, Pauline J; Chang, Frank W; Yuen, Michelle C; Horsley, David A; Otillar, Robert

    2014-01-01

    Low-cost, easily-fabricated and power-efficient microvalves are necessary for many microfluidic lab-on-a-chip applications. In this study, we present a simple, low-power, scalable, CMOS-compatible magnetic actuator for microvalve applications composed of a paramagnetic bead as the ball valve over a picoliter reaction well etched into a silicon substrate. The paramagnetic bead, composed of either pure FeSi or magnetite in a SiO 2  matrix, is actuated by the local magnetic field gradient generated by a microcoil in an aqueous environment, and the reaction well is situated at the microcoil center. A permanent magnet beneath the microvalve device provides an external magnetic biasing field that magnetizes the bead, enabling bidirectional actuation and reducing the current required to actuate the bead to a level below 10 mA. The vertical and radial magnetic forces exerted on the bead by the microcoil were measured for both pure FeSi and composite beads and agree well with the predictions of 2D axisymmetric finite element method models. Vertical forces were within a range of 13–80 nN, and radial forces were 11–60 nN depending on the bead type. The threshold current required to initiate bead actuation was measured as a function of bead diameter and is found to scale inversely with volume for small beads, as expected based on the magnetic force model. To provide an estimate of the stiction force acting between the bead and the passivation layer on the substrate, repeated actuation trials were used to study the bead throw distance for substrates coated with silicon dioxide, Parylene-C, and photoresist. The stiction observed was lowest for a photoresist-coated substrate, while silicon dioxide and Parylene-C coated substrates exhibited similar levels of stiction. (paper)

  18. [Outcomes, controversies and gastric volume after laparoscopic sleeve gastrectomy in the treatment of obesity].

    Science.gov (United States)

    García-Díaz, Juan José; Ferrer-Márquez, Manuel; Moreno-Serrano, Almudena; Barreto-Rios, Rogelio; Alarcón-Rodríguez, Raquel; Ferrer-Ayza, Manuel

    2016-01-01

    Laparoscopic sleeve gastrectomy is a surgical procedure for the treatment of morbid obesity. However, there are still controversies regarding its efficiency in terms of weight reduction and incidence of complications. In this prospective study, the experience is presented of a referral centre for the treatment of morbid obesity with laparoscopic sleeve gastrectomy. A prospective study on 73 patients subjected to laparoscopic sleeve gastrectomy from February 2009 to September 2013. Patients were followed-up for a period of 12 months, evaluating the development of complications, reduction of gastric volume, and the weight loss associated with the surgery, as well as their impact on the improvement of comorbidities present at beginning of the study. There was a statistically a significantly reduction between the preoperative body mass index (BMI) and the BMI at 12 months after laparoscopic sleeve gastrectomy (p < 0.001), despite there being an increase in the gastric volume during follow-up, measured at one month and 12 months after surgery (p < 0.001). Five patients (6.85%) had complications, with none of them serious and with no deaths in the whole series. Laparoscopic sleeve gastrectomy is a safe and effective technique for the treatment of morbid obesity. Its use is associated with a significant reduction in the presence of comorbidities associated with obesity. Multicentre studies with a longer period of monitoring are required to confirm the efficacy and safety of this surgical technique. Copyright © 2015 Academia Mexicana de Cirugía A.C. Publicado por Masson Doyma México S.A. All rights reserved.

  19. Influence of Elastic Bandage and Neoprene Sleeve on Knee Position Sense and Pain in Subjects with Knee Osteoarthritis

    Directory of Open Access Journals (Sweden)

    Basir Majdoleslami

    2003-12-01

    Full Text Available Objective: to investigate whether a neoprene sleeve and elastic bandage around the knee joint of subjects with knee osteoarthritis (OA would , in short term (a reduce pain (b improve knee joint position sense and comparison of their effect with each other if they have. Materials & Methods: In a semi-experimental study, 30 subjects (11 men, 19 women, age between 33-75 with unilateral knee OA. Subjects had to have at least 2cm from 10cm visual analogue scale (VAS of knee pain for study entry.All patients were randomly assigned to either an elastic bandage or a neoprene sleeve. One week later they were assigned to the opposite selection. Joint position sense was assessed in the sitting position using an electrogoniometer and pain by VAS where 0cm equals no pain and 10 cm equals worst pain. Knee pain and JPS were assessed for each selection one week apart. During each visit assessment were performed at baseline and after 20 min of bandage/neoprene sleeve application. Results: the mean of scores for knee variables JPS and VAS was taken and paired-t test and Wilcoxon signed rank test was employed to calculate the different between two trails. Neoprene sleeve had significant effect on knee JPS (P=0.037. But elastic bandage had no effect (P=0.631. Both of them had significantly reduced knee pain. (P=0.000 Conclusion: In subjects with both neoprene sleeve and elastic bandage reduced knee pain with more effect of neoprene sleeve. Only the neoprene sleeve had effect on knee JPS.

  20. A light writable microfluidic "flash memory": optically addressed actuator array with latched operation for microfluidic applications.

    Science.gov (United States)

    Hua, Zhishan; Pal, Rohit; Srivannavit, Onnop; Burns, Mark A; Gulari, Erdogan

    2008-03-01

    This paper presents a novel optically addressed microactuator array (microfluidic "flash memory") with latched operation. Analogous to the address-data bus mediated memory address protocol in electronics, the microactuator array consists of individual phase-change based actuators addressed by localized heating through focused light patterns (address bus), which can be provided by a modified projector or high power laser pointer. A common pressure manifold (data bus) for the entire array is used to generate large deflections of the phase change actuators in the molten phase. The use of phase change material as the working media enables latched operation of the actuator array. After the initial light "writing" during which the phase is temporarily changed to molten, the actuated status is self-maintained by the solid phase of the actuator without power and pressure inputs. The microfluidic flash memory can be re-configured by a new light illumination pattern and common pressure signal. The proposed approach can achieve actuation of arbitrary units in a large-scale array without the need for complex external equipment such as solenoid valves and electrical modules, which leads to significantly simplified system implementation and compact system size. The proposed work therefore provides a flexible, energy-efficient, and low cost multiplexing solution for microfluidic applications based on physical displacements. As an example, the use of the latched microactuator array as "normally closed" or "normally open" microvalves is demonstrated. The phase-change wax is fully encapsulated and thus immune from contamination issues in fluidic environments.

  1. A Delphi Consensus of the Crucial Steps in Gastric Bypass and Sleeve Gastrectomy Procedures in the Netherlands.

    Science.gov (United States)

    Kaijser, Mirjam A; van Ramshorst, Gabrielle H; Emous, Marloes; Veeger, Nic J G M; van Wagensveld, Bart A; Pierie, Jean-Pierre E N

    2018-04-09

    Bariatric procedures are technically complex and skill demanding. In order to standardize the procedures for research and training, a Delphi analysis was performed to reach consensus on the practice of the laparoscopic gastric bypass and sleeve gastrectomy in the Netherlands. After a pre-round identifying all possible steps from literature and expert opinion within our study group, questionnaires were send to 68 registered Dutch bariatric surgeons, with 73 steps for bypass surgery and 51 steps for sleeve gastrectomy. Statistical analysis was performed to identify steps with and without consensus. This process was repeated to reach consensus of all necessary steps. Thirty-eight participants (56%) responded in the first round and 32 participants (47%) in the second round. After the first Delphi round, 19 steps for gastric bypass (26%) and 14 for sleeve gastrectomy (27%) gained full consensus. After the second round, an additional amount of 10 and 12 sub-steps was confirmed as key steps, respectively. Thirteen steps in the gastric bypass and seven in the gastric sleeve were deemed advisable. Our expert panel showed a high level of consensus expressed in a Cronbach's alpha of 0.82 for the gastric bypass and 0.87 for the sleeve gastrectomy. The Delphi consensus defined 29 steps for gastric bypass and 26 for sleeve gastrectomy as being crucial for correct performance of these procedures to the standards of our expert panel. These results offer a clear framework for the technical execution of these procedures.

  2. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection for non-small cell lung cancer.

    Science.gov (United States)

    Li, Shuben; Chai, Huiping; Huang, Jun; Zeng, Guangqiao; Shao, Wenlong; He, Jianxing

    2014-04-01

    The purpose of the current study is to present the clinical and surgical results in patients who underwent hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection. Thirty-one patients, 27 men and 4 women, underwent segmental-main bronchial sleeve anastomoses for non-small cell lung cancer between May 2004 and May 2011. Twenty-six (83.9%) patients had squamous cell carcinoma, and 5 patients had adenocarcinoma. Six patients were at stage IIB, 24 patients at stage IIIA, and 1 patient at stage IIIB. Secondary sleeve anastomosis was performed in 18 patients, and Y-shaped multiple sleeve anastomosis was performed in 8 patients. Single segmental bronchiole anastomosis was performed in 5 cases. The average time for chest tube removal was 5.6 days. The average length of hospital stay was 11.8 days. No anastomosis fistula developed in any of the patients. The 1-, 2-, and 3-year survival rates were 83.9%, 71.0%, and 41.9%, respectively. Hybrid video-assisted thoracic surgery with segmental-main bronchial sleeve resection is a complex technique that requires training and experience, but it is an effective and safe operation for selected patients.

  3. Management of Distal Gastric Leak After Laparoscopic Sleeve Gastrectomy by Double Pigtail Catheter

    Directory of Open Access Journals (Sweden)

    Mani Habibi

    2016-07-01

    Full Text Available Gastric leakage postsurgery is the most feared complication of laparoscopic sleeve gastrectomy due to the difficulty of its management. While gastric leakagemanagement postsurgery is often performed using internal drainage catheters accompanied by self-expandable metal stents, endoscopic internal drainage by double pigtail catheter has recently become a recommended approach. Here we describe our treatment of a patient who experienced distal gastric leakage after undergoing laparoscopic sleeve gastrectomy using double pigtail catheter and our treatment recommendations based on the patient outcome.

  4. Polymer/inorganic superhydrophobic surfaces.

    Energy Technology Data Exchange (ETDEWEB)

    Collord, Andrew; Kissel, David J.; Brinker, C. Jeffrey; Apblett, Christopher Alan; Branson, Eric D.

    2009-09-01

    We have designed and built electrostatically actuated microvalves compatible with integration into a PDMS based microfluidic system. The key innovation for electrostatic actuation was the incorporation of carbon nanotubes into the PDMS valve membrane, allowing for electrostatic charging of the PDMS layer and subsequent discharging, while still allowing for significant distention of the valveseat for low voltage control of the system. Nanoparticles were applied to semi-cured PDMS using a stamp transfer method, and then cured fully to make the valve seats. DC actuation in air of these valves yielded operational voltages as low as 15V, by using a supporting structure above the valve seat that allowed sufficient restoring forces to be applied while not enhancing actuation forces to raise the valve actuation potential. Both actuate to open and actuate to close valves have been demonstrated, and integrated into a microfluidic platform, and demonstrated fluidic control using electrostatic valves.

  5. A study on a characteristic of stem friction coefficient for motor operated flexible wedge gate valve

    International Nuclear Information System (INIS)

    Kim, Dae-Woong; Park, Sung-Geun; Lee, Sang-Guk; Kang, Shin-Cheul

    2009-01-01

    Stem friction coefficient is a coefficient that represents friction between thread leads of the stem and stem nut. It is an important factor to determine output thrust delivered from the actuator to the valve stem in assessing performance of motor operated valves. This study analyzes the effects of changes in differential pressure on stem friction coefficient, and determines the bounding value of stem friction coefficient. A dynamic test was conducted on multiple flexible wedge gate valves in various differential pressure conditions, and the test data was statistically analyzed to determine the bounding value. The results show that stem friction coefficient in middle and high differential pressure is influenced by fluid pressure, while stem friction coefficient in low differential pressure is almost not affected by fluid pressure. In addition, it is found that the bounding value of stem friction coefficient is higher in a closing stroke than in an opening stroke.

  6. Acoustic-Modal Testing of the Ares I Launch Abort System Attitude Control Motor Valve

    Science.gov (United States)

    Davis, R. Benjamin; Fischbach, Sean R.

    2010-01-01

    The Attitude Control Motor (ACM) is being developed for use in the Launch Abort System (LAS) of NASA's Ares I launch vehicle. The ACM consists of a small solid rocket motor and eight actuated pintle valves that directionally allocate.thrust_- 1t.has-been- predicted-that significant unsteady. pressure.fluctuations.will.exist. inside the-valves during operation. The dominant frequencies of these oscillations correspond to the lowest several acoustic natural frequencies of the individual valves. An acoustic finite element model of the fluid volume inside the valve has been critical to the prediction of these frequencies and their associated mode shapes. This work describes an effort to experimentally validate the acoustic finite model of the valve with an acoustic modal test. The modal test involved instrumenting a flight-like valve with six microphones and then exciting the enclosed air with a loudspeaker. The loudspeaker was configured to deliver broadband noise at relatively high sound pressure levels. The aquired microphone signals were post-processed and compared to results generated from the acoustic finite element model. Initial comparisons between the test data and the model results revealed that additional model refinement was necessary. Specifically, the model was updated to implement a complex impedance boundary condition at the entrance to the valve supply tube. This boundary condition models the frequency-dependent impedance that an acoustic wave will encounter as it reaches the end of the supply tube. Upon invoking this boundary condition, significantly improved agreement between the test data and the model was realized.

  7. Laparoscopic Sleeve Gastrectomy Improves Olfaction Sensitivity in Morbidly Obese Patients.

    Science.gov (United States)

    Hancı, Deniz; Altun, Huseyin; Altun, Hasan; Batman, Burcin; Karip, Aziz Bora; Serin, Kursat Rahmi

    2016-03-01

    Olfactory abilities of the patients are known to be altered by eating and metabolic disorders, including obesity. There are only a number of studies investigating the effect of obesity on olfaction, and there is limited data on the changes in olfactory abilities of morbidly obese patients after surgical treatment. Here we investigated the changes in olfactory abilities of 54 morbidly obese patients (M/F, 22/32; age range 19-57 years; body mass index (BMI) range 30.5-63.0 kg/m(2)) after laparoscopic sleeve gastrectomy. A laparoscopic sleeve gastrectomy was performed by the same surgeon using five-port technique. Olfactory abilities were tested preoperatively and 1, 3, and 6 months after the surgery using a standardized Sniffin' Sticks Extended Test kit. Analyses of variance indicated statistically significant improvement in T, D, and I scores of morbidly obese patients within time factors (preoperative vs. 1, 3, and 6 months; 1 vs. 3 and 6 months; and 3 vs. 6 months; p < 0.001 for all). There was a statistically significant improvement in overall TDI scores with an increase from 25 to 41 during the 6 months follow-up period (p < 0.001 for all). Here, for the first time in literature, we were able to show the significant improvement in olfactory abilities of morbidly obese patients after laparoscopic sleeve gastrectomy.

  8. The effects of sleeve gastectomy on gastro-esophageal reflux and gastro-esophageal motility.

    Science.gov (United States)

    Hayat, Jamal O; Wan, Andrew

    2014-05-01

    Sleeve gastrectomy is an increasingly performed bariatric procedure associated with low morbidity and good short to medium term effects on weight loss and comorbid conditions. Studies assessing the prevalence of post-operative gastro-esophageal reflux disease (GERD), show sleeve gastrectomy may provoke de novo GERD symptoms or worsening of pre-existing GERD. Pathophysiological mechanisms of GERD after sleeve gastrectomy include a hypotensive lower esophageal sphincter, increased gastro-esophageal pressure gradient and intra-thoracic migration of the remnant stomach. A reduction in the compliance of the gastric remnant may provoke an increase in transient lower esophageal sphincter relaxations. Time-resolved MRI suggests relative gastric stasis in the proximal remnant and increased emptying from the antrum. A lack of standardisation of technique, along with heterogeneity of studies assessing GERD may explain the wide variability in reported results. Simultaneous and careful repair of an associated hiatus hernia may result in a reduction in the prevalence of post-operative GERD.

  9. Is a sleeve lobectomy significantly better than a pneumonectomy?

    Science.gov (United States)

    Stallard, Joseph; Loberg, Anna; Dunning, Joel; Dark, John

    2010-11-01

    A best evidence topic was written according to a structured protocol. The question addressed was 'whether a sleeve lobectomy results in a better survival rate than a pneumonectomy in suitable patients?' Altogether, more than 327 papers were found using the reported search, of which 15 represented the best evidence to answer the clinical question. The authors, journal, date and country of publication, patient group studied, study type, relevant outcomes and results of these papers are tabulated. We conclude in the biggest meta-analysis of nearly 3000 patients, the five-year survival was 50% for sleeve lobectomy compared to 30% for pneumonectomy. Operative mortality was 3% vs. 6% for pneumonectomy, and locoregional recurrence was 17% vs. 30%. These results are broadly consistent across all the 13 cohort studies presented here many of which document a 20-year single centre experience or more. There are significant issues in all cohort studies on this subject as, due to their non-randomized nature, the reason for not performing a sleeve resection may well have been more advanced disease, which would necessarily mean that the pneumonectomy patients would have a lower expected survival and higher local recurrence. In addition, there have been many large cohort studies to date and thus no more are required, as future studies are unlikely to resolve this issue. Thus, the only study that would adequately correct for this issue would be a randomized trial, but to prove a 10% increase in five-year survival a 300 patient study would be needed. This is bigger than any study ever done in this area and as some centres took 30 years to collect these numbers of potential sleeve patients an RCT is not a realistic possibility. Therefore, we conclude that no more cohort studies should be performed, as the results will be consistent with the meta-analyses and an RCT to eliminate their bias is unattainable, and thus no more research should be done on this topic and surgeons should use

  10. Heat Generation and Efficiency of a New Modified Phaco Tip and Sleeve.

    Directory of Open Access Journals (Sweden)

    Aeri Yoo

    Full Text Available To compare a modified phacoemulsification tip with the established micro tip, in terms of temperature at the corneal wound, efficiency, and chatter events, using the Centurion® Vision system.Eighty porcine eyes were randomized into 4 groups: 1sleeveless conventional 45D MiniFlared ABS® Kelman tip (1.1-mm incision; 2sleeveless new modified 45D ABS® INTREPID® balanced tip(1.1-mm incision; 3 Kelman tip with own sleeve (2.2-mm incision; 4Balanced tip with modified 4-rib sleeve (2.2-mm incision. Measurements were taken with 2 settings: longitudinal(power 40% and 70% and torsional mode (power 40% and 100%. Peak temperatures were measured 0, 10, 30, and 60 seconds after continuous ultrasound power. For the efficiency test, porcine lens nuclei were formalin soaked and cut into 2.0 mm3 cubes. Efficiency and chatter were examined.In all longitudinal settings, the sleeveless groups(1 and 2 showed lower temperatures than the sleeved groups(3 and 4 (P = 0.003. In 100% torsional mode, groups 3 and 4 produced significantly different temperatures(37.13 ± 1.44 and 35.14 ± 0.54, respectively; P = 0.007.The efficiency, in a 100% power torsional setting, was13.52 ± 2.60 sec for group 4, and 44.45± 14.75 sec for group 3 (P<0.001.The two different bare tips show no significant differences in thermogenesis. However, the balanced tip with sleeve produces lower temperaturesat100% torsional power and better efficiency than the Kelman tip.

  11. Wearing long sleeves while prepping a patient in the operating room decreases airborne contaminants.

    Science.gov (United States)

    Markel, Troy A; Gormley, Thomas; Greeley, Damon; Ostojic, John; Wagner, Jennifer

    2018-04-01

    The use of long sleeves by nonscrubbed personnel in the operating room has been called into question. We hypothesized that wearing long sleeves and gloves, compared with having bare arms without gloves, while applying the skin preparation solution would decrease particulate and microbial contamination. A mock patient skin prep was performed in 3 different operating rooms. A long-sleeved gown and gloves, or bare arms, were used to perform the procedure. Particle counters were used to assess airborne particulate contamination, and active and passive microbial assessment was achieved through air samplers and settle plate analysis. Data were compared with Student's t-test or Mann-Whitney U, and P airborne contamination while the skin prep is applied, which may lead to decreased surgical site infections. Copyright © 2018 Association for Professionals in Infection Control and Epidemiology, Inc. Published by Elsevier Inc. All rights reserved.

  12. Note: A novel rotary actuator driven by only one piezoelectric actuator.

    Science.gov (United States)

    Huang, Hu; Fu, Lu; Zhao, Hongwei; Shi, Chengli; Ren, Luquan; Li, Jianping; Qu, Han

    2013-09-01

    This paper presents a novel piezo-driven rotary actuator based on the parasitic motion principle. Output performances of the rotary actuator were tested and discussed. Experiment results indicate that using only one piezoelectric actuator and simple sawtooth wave control, the rotary actuator reaches the rotation velocity of about 20,097 μrad/s when the driving voltage is 100 V and the driving frequency is 90 Hz. The actuator can rotate stably with the minimum resolution of 0.7 μrad. This paper verifies feasibility of the parasitic motion principle for applications of rotary actuators, providing new design ideas for precision piezoelectric rotary actuators.

  13. Pump integrated closed loop control. The intelligent actuator pump - state of the art and perspectives; Pumpenintegrierte Prozessregelung. Der intelligente Aktor Pumpe - Stand und Moeglichkeiten

    Energy Technology Data Exchange (ETDEWEB)

    Paulus, Thomas; Schullerer, Joachim; Oesterle, Manfred [KSB AG, Frankenthal (Germany)

    2009-07-01

    In many areas of industrial automation, centrifugal pumps and systems of centrifugal pumps are important actuators of a process und therefore a fundamental part of the entire plant. In contrary to the controlled valves, located behind the pump in the pipework system, the functions of the intelligent actuator pump or system of pumps are rarely used and noticed. With regard to the reduction of life cycle costs of the asset pump, pump integrated closed loop control of the fluid transport task has advantages over central closed loop control e.g. in a process control system. This article contains a survey of the intelligent actuator pump, its structure and functions with regard to the solution of the fluid transport task and according pump integrated closed loop control. (orig.)

  14. Design of a Lightweight Soft Robotic Arm Using Pneumatic Artificial Muscles and Inflatable Sleeves.

    Science.gov (United States)

    Ohta, Preston; Valle, Luis; King, Jonathan; Low, Kevin; Yi, Jaehyun; Atkeson, Christopher G; Park, Yong-Lae

    2018-04-01

    As robots begin to interact with humans and operate in human environments, safety becomes a major concern. Conventional robots, although reliable and consistent, can cause injury to anyone within its range of motion. Soft robotics, wherein systems are made to be soft and mechanically compliant, are thus a promising alternative due to their lightweight nature and ability to cushion impacts, but current designs often sacrifice accuracy and usefulness for safety. We, therefore, have developed a bioinspired robotic arm combining elements of rigid and soft robotics such that it exhibits the positive qualities of both, namely compliance and accuracy, while maintaining a low weight. This article describes the design of a robotic arm-wrist-hand system with seven degrees of freedom (DOFs). The shoulder and elbow each has two DOFs for two perpendicular rotational motions on each joint, and the hand has two DOFs for wrist rotations and one DOF for a grasp motion. The arm is pneumatically powered using custom-built McKibben type pneumatic artificial muscles, which are inflated and deflated using binary and proportional valves. The wrist and hand motions are actuated through servomotors. In addition to the actuators, the arm is equipped with a potentiometer in each joint for detecting joint angle changes. Simulation and experimental results for closed-loop position control are also presented in the article.

  15. Clinical practice guidelines for rest orthosis, knee sleeves, and unloading knee braces in knee osteoarthritis.

    Science.gov (United States)

    Beaudreuil, Johann; Bendaya, Samy; Faucher, Marc; Coudeyre, Emmanuel; Ribinik, Patricia; Revel, Michel; Rannou, François

    2009-12-01

    To develop clinical practice guidelines concerning the use of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis. The French Physical Medicine and Rehabilitation Society (SOFMER) methodology, associating a systematic literature review, collection of everyday clinical practice, and external review by multidisciplinary expert panel, was used. Few high-level studies of bracing for knee osteoarthritis were found. No evidence exists for the effectiveness of rest orthosis. Evidence for knee sleeves suggests that they decrease pain in knee osteoarthritis, and their use is associated with subjective improvement. These actions do not appear to depend on a local thermal effect. The effectiveness of knee sleeves for disability is not demonstrated for knee osteoarthritis. Short- and mid-term follow-up indicates that valgus knee bracing decreases pain and disability in medial knee osteoarthritis, appears to be more effective than knee sleeves, and improves quality of life, knee proprioception, quadriceps strength, and gait symmetry, and decreases compressive loads in the medial femoro-tibial compartment. However, results of response to valgus knee bracing remain inconsistent; discomfort and side effects can result. Thrombophlebitis of the lower limbs has been reported with the braces. Braces, whatever kind, are infrequently prescribed in clinical practice for osteoarthritis of the lower limbs. Modest evidence exists for the effectiveness of bracing--rest orthosis, knee sleeves and unloading knee braces--for knee osteoarthritis, with only low level recommendations for its use. Braces are prescribed infrequently in French clinical practice for osteoarthritis of the knee. Randomized clinical trials concerning bracing in knee osteoarthritis are still necessary.

  16. Fracturing mechanics before valve-in-valve therapy of small aortic bioprosthetic heart valves.

    Science.gov (United States)

    Johansen, Peter; Engholt, Henrik; Tang, Mariann; Nybo, Rasmus F; Rasmussen, Per D; Nielsen-Kudsk, Jens Erik

    2017-10-13

    Patients with degraded bioprosthetic heart valves (BHV) who are not candidates for valve replacement may benefit from transcatheter valve-in-valve (VIV) therapy. However, in smaller-sized surgical BHV the resultant orifice may become too narrow. To overcome this, the valve frame can be fractured by a high-pressure balloon prior to VIV. However, knowledge on fracture pressures and mechanics are prerequisites. The aim of this study was to identify the fracture pressures needed in BHV, and to describe the fracture mechanics. Commonly used BHV of small sizes were mounted on a high-pressure balloon situated in a biplane fluoroscopic system with a high-speed camera. The instant of fracture was captured along with the balloon pressure. The valves were inspected for material protrusion and later dissected for fracture zone investigation and description. The valves with a polymer frame fractured at a lower pressure (8-10 atm) than those with a metal stent (19-26 atm). None of the fractured valves had elements protruding. VIV procedures in small-sized BHV may be performed after prior fracture of the valve frame by high-pressure balloon dilatation. This study provides tentative guidelines for expected balloon sizes and pressures for valve fracturing.

  17. Perspectives of the fully variable valve train univalve on the basis of a 2.0 l spark-ignition engine; Perspektiven des vollvariablen Ventiltriebs Univalve auf Basis eines 2,0-l-Ottomotors

    Energy Technology Data Exchange (ETDEWEB)

    Flierl, R. [Lehrstuhl fuer Verbrennungskraftmaschinen der Technischen Univ. Kaiserslautern (Germany); Entec Consulting GmbH, Hemer (Germany); Gollasch, D. [Lehrstuhl fuer Verbrennungsmotoren der Univ. Kaiserslautern (Germany); Knecht, A.; Pohl, D. [Hydraulik-Ring GmbH, Nuertingen (Germany); Hannibal, W. [Lab. fuer Konstruktion und CAE-Anwendungen, Fachhochschule Suedwestfalen, Iserlohn (Germany); Entec Consulting GmbH, Hemer (Germany)

    2006-07-15

    This article provides the first test results of a fired four cylinder gasoline engin with the new fully variable valve timing system 'Univalve'. This variable valve actuation system is under development by the Hilite / Hydraulik-Ring company for series production engines. The basic investigations are taking place at the University of Kaiserslautern at the institute of combustion engines. Only by changes at the intake valve train, the fuel consumption could be improved by 13% compared to the otherwise identical basic engine. Essential engine functions like torque and emissions were also clearly improved. (orig.)

  18. Flight control actuation system

    Science.gov (United States)

    Wingett, Paul T. (Inventor); Gaines, Louie T. (Inventor); Evans, Paul S. (Inventor); Kern, James I. (Inventor)

    2006-01-01

    A flight control actuation system comprises a controller, electromechanical actuator and a pneumatic actuator. During normal operation, only the electromechanical actuator is needed to operate a flight control surface. When the electromechanical actuator load level exceeds 40 amps positive, the controller activates the pneumatic actuator to offset electromechanical actuator loads to assist the manipulation of flight control surfaces. The assistance from the pneumatic load assist actuator enables the use of an electromechanical actuator that is smaller in size and mass, requires less power, needs less cooling processes, achieves high output forces and adapts to electrical current variations. The flight control actuation system is adapted for aircraft, spacecraft, missiles, and other flight vehicles, especially flight vehicles that are large in size and travel at high velocities.

  19. Seismic retrofit of spliced sleeve connections for precast bridge piers.

    Science.gov (United States)

    2017-03-01

    Grouted Splice Sleeve (GSS) connectors are being considered for connecting bridge columns, footings, and pier caps in Accelerated Bridge Construction (ABC). A repair technique for precast reinforced concrete bridge column-to-footing and column-to-pie...

  20. Sleeving-back of horizontal wells to control downstream oil saturation and improve oil recovery

    Energy Technology Data Exchange (ETDEWEB)

    Greaves, M.; Saghr, A. M. [Bath Univ (United Kingdom)

    1998-12-31

    Air injection has become popular as an enhanced recovery technology, applicable over a wide variety of reservoir conditions including heavy, medium and light oils. One problem observed in light oil reservoirs is the tendency to desaturate the oil layer downstream of the moving front. This is particularly common in the case of thermal recovery processes. In this experiment designed to study ways to restrict the de-saturation of the oil layer, a modified horizontal producer well, incorporating a `sleeve-back` principal was used. The objective was to replicate the `toe-to-heel` displacement process occurring during heavy oil recovery, wherein downstream oil is essentially immobile due to its high viscosity. The `sleeve-back` of the well was achieved using a co-aligned, two-well assembly, so that the upstream section of the horizontal producer well was active, and continuously adjusted during propagation of the combustion front. The use of this continuous `sleeve-back` operation to control the level of de-saturation in the downstream section of a sand pack was successful as confirmed by the very high oil recovery achieved, equivalent to 93.5 per cent of oil in place. The level of CO{sub 2} production was also very high. The `sleeve-back` of the horizontal producer well made the light oil in-situ combustion more efficient compared to what would be expected in a fully-open well. The `sleeve-back` of the well also produced thermal contours in the sand pack that closely resembled those observed with heavy, highly viscous oil. By sealing-off the otherwise open well in the downstream part of the reservoir, the de-saturation of the oil layer was prevented. 9 refs., 4 tabs., 9 figs.

  1. Wear Resistance of Piston Sleeve Made of Layered Material Structure: MMC A356R, Anti-Abrasion Layer and FGM Interface

    Directory of Open Access Journals (Sweden)

    Hernik Szymon

    2016-09-01

    Full Text Available The aim of this paper is the numerical analysis of the one of main part of car engine – piston sleeve. The first example is for piston sleeve made of metal matrix composite (MMC A356R. The second improved material structure is layered. Both of them are comparison to the classical structure of piston sleeve made of Cr-Ni stainless steel. The layered material structure contains the anti-abrasion layer at the inner surface of piston sleeve, where the contact and friction is highest, FGM (functionally graded material interface and the layer of virgin material on the outer surface made of A356R. The complex thermo-elastic model with Archard's condition as a wear law is proposed. The piston sleeve is modelling as a thin walled cylindrical axisymmetric shell. The coupled between the formulation of thermo-elasticity of cylindrical axisymmetric shell and the Archard’s law with functionally changes of local hardness is proposed.

  2. Storage envelopes or sleeves

    International Nuclear Information System (INIS)

    Freshwater, J.R.; Wagman, P.I.

    1980-01-01

    A storage envelope or sleeve particularly for processed X-ray films is described. It consists of front and back panels joined together at a hinge line and connected along the intermediate sides by connecting flaps. An inner pocket is formed from a third flap which is folded to lie against the inner face of the back panel. The panels may have additional score lines parallel to the closed sides of the envelope and the inner pocket so that the envelope and the inner pocket can accommodate bulky contents. The free edge of the pocket is inset from the open side of the envelope, and finger cut-outs may be provided to facilitate access to the contents of the envelope and the pocket. (author)

  3. Fluid-driven reciprocating apparatus and valving for controlling same

    Science.gov (United States)

    Whitehead, John C.; Toews, Hans G.

    1993-01-01

    A control valve assembly for alternately actuating a pair of fluid-driven free-piston devices by using fluid pressure communication therebetween. Each control valve is switched by a pressure signal depending on the state of its counterpart's piston. The communication logic is arranged to provide overlap of the forward strokes of the pistons, so that at least one of the pair will always be pressurized. Thus, uninterrupted pumping of liquid is made possible from a pair of free-piston pumps. In addition, the speed and frequency of piston stroking is entirely dependent on the mechanical power load applied. In the case of a pair of pumps, this enables liquid delivery at a substantially constant pressure over the full range of flow rates, from zero to maximum flow. One embodiment of the invention utilized two pairs of fluid-driven free-piston devices whereby a bipropellant liquid propulsion system may be operated, so as to provide continuous flow of both fuel and oxidizer liquids when used in rocket applications, for example.

  4. Application of RELAP5/MOD3.3 to Calculate Thermal Hydraulic Behavior of the Pressurizer Safety Valve Performance Test Facility

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Kim, Young Ae; Oh, Seung Jong; Park, Jong Woon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2007-10-15

    The increase of the acceptance tolerance of Pressurizer Safety Valve (PSV) test is vital for the safe operation of nuclear power plants because the frequent tests may make the valves decrepit and become a cause of leak. Recently, Korea Hydro and Nuclear Power Company (KHNP) is building a PSV performance test facility to provide the technical background data for the relaxation of the acceptance tolerance of PSV including the valve pop-up characteristics and the loop seal dynamics (if the plant has the loop seal in the upstream of PSV). The discharge piping and supports must be designed to withstand severe transient hydrodynamic loads when the safety valve actuates. The evaluation of hydrodynamic loads is a two-step process: first the thermal hydraulic behavior in the piping must be defined, and then the hydrodynamic loads are calculated from the thermal hydraulic parameters such as pressure and mass flow. The hydrodynamic loads are used as input to the structural analysis.

  5. The new Toyota variable valve timing and lift system

    Energy Technology Data Exchange (ETDEWEB)

    Shimizu, K.; Fuwa, N.; Yoshihara, Y. [Toyota Motor Corporation (Japan); Hori, K. [Toyota Boshoku Corporation (Japan)

    2007-07-01

    A continuously variable valve timing (duration and phase) and lift system was developed. This system was applied to the valvetrain of a new 2.0L L4 engine (3ZRFAE) for the Japanese market. The system has rocker arms, which allow continuously variable timing and lift, situated between a conventional roller-rocker arm and the camshaft, an electromotor actuator to drive it and a phase mechanism for intake and exhaust camshafts (Dual VVT-i). The rocking center of the rocker arm is stationary, and the axial linear motion of a helical spline changes the initial phase of the rocker arm which varies the timing and lift. The linear motion mechanism uses an original planetary roller screw and is driven by a brushless motor with a built-in electric control unit. Since the rocking center and the linear motion helical spline center coincide, a compact cylinder head design was possible, and the cylinder head is a common design with a conventional engine. Since the ECU controls intake valve duration and timing, a fuel economy gain of maximum 10% (depending on driving condition) is obtained by reducing light to medium load pumping losses. Also intake efficiency was maximized throughout the speed range, resulting in a power gain of 10%. Further, HC emissions were reduced due to increased air speed at low valve lift. (orig.)

  6. Check valve

    Science.gov (United States)

    Upton, H.A.; Garcia, P.

    1999-08-24

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs.

  7. Check valve

    International Nuclear Information System (INIS)

    Upton, H.A.; Garcia, P.

    1999-01-01

    A check valve for use in a GDCS of a nuclear reactor and having a motor driven disk including a rotatable armature for rotating the check valve disk over its entire range of motion is described. In one embodiment, the check valve includes a valve body having a coolant flow channel extending therethrough. The coolant flow channel includes an inlet end and an outlet end. A valve body seat is located on an inner surface of the valve body. The check valve further includes a disk assembly, sometimes referred to as the motor driven disc, having a counterweight and a disk shaped valve. The disk valve includes a disk base having a seat for seating with the valve body seat. The disk assembly further includes a first hinge pin member which extends at least partially through the disk assembly and is engaged to the disk. The disk valve is rotatable relative to the first hinge pin member. The check valve also includes a motor having a stator frame with a stator bore therein. An armature is rotatably positioned within the stator bore and the armature is coupled to the disk valve to cause the disk valve to rotate about its full range of motion. 5 figs

  8. Advanced Launch System (ALS): Electrical actuation and power systems improve operability and cost picture

    Science.gov (United States)

    Sundberg, Gale R.

    1990-01-01

    To obtain the Advanced Launch System (ALS) primary goals of reduced costs and improved operability, there must be significant reductions in the launch operations and servicing requirements relative to current vehicle designs and practices. One of the primary methods for achieving these goals is by using vehicle electrical power system and controls for all actuation and avionics requirements. A brief status review of the ALS and its associated Advanced Development Program is presented to demonstrate maturation of those technologies that will help meet the overall operability and cost goals. The electric power and actuation systems are highlighted as a specific technology ready not only to meet the stringent ALS goals (cryogenic field valves and thrust vector controls with peak power demands to 75 hp), but also those of other launch vehicles, military and civilian aircraft, lunar/Martian vehicles, and a multitude of commercial applications.

  9. NRC valve performance test program - check valve testing

    International Nuclear Information System (INIS)

    Jeanmougin, N.M.

    1987-01-01

    The Valve Performance Test Program addresses the current requirements for testing of pressure isolation valves (PIVs) in light water reactors. Leak rate monitoring is the current method used by operating commercial power plants to survey the condition of their PIVs. ETEC testing of three check valves (4-inch, 6-inch, and 12-inch nominal diameters) indicates that leak rate testing is not a reliable method for detecting impending valve failure. Acoustic emission monitoring of check valves shows promise as a method of detecting loosened internals damage. Future efforts will focus on evaluation of acoustic emission monitoring as a technique for determining check valve condition. Three gate valves also will be tested to evaluate whether the check valve results are applicable to gate type PIVs

  10. Transcatheter, valve-in-valve transapical aortic and mitral valve implantation, in a high risk patient with aortic and mitral prosthetic valve stenoses

    Directory of Open Access Journals (Sweden)

    Harish Ramakrishna

    2015-01-01

    Full Text Available Transcatheter valve implantation continues to grow worldwide and has been used principally for the nonsurgical management of native aortic valvular disease-as a potentially less invasive method of valve replacement in high-risk and inoperable patients with severe aortic valve stenosis. Given the burden of valvular heart disease in the general population and the increasing numbers of patients who have had previous valve operations, we are now seeing a growing number of high-risk patients presenting with prosthetic valve stenosis, who are not potential surgical candidates. For this high-risk subset transcatheter valve delivery may be the only option. Here, we present an inoperable patient with severe, prosthetic valve aortic and mitral stenosis who was successfully treated with a trans catheter based approach, with a valve-in-valve implantation procedure of both aortic and mitral valves.

  11. Simulation and Experimental Testing of an Actuator for a Fast Switching On-Off Valve Suitable to Efficient Displacement Machines

    DEFF Research Database (Denmark)

    Roemer, Daniel Beck; Johansen, Per; Bech, Michael Møller

    2014-01-01

    Digital Displacement (DD) fluid power machines are upcoming technology, improving the efficiency compared to traditional variable displacement machines, especially at low displacements where currently available fluid power pumps/motors suffer from mediocre efficiency. This efficiency improvement...... is made possible using independent electronically controlled seat valves for each pressure chamber, which is controlled corresponding to the rotation of the crankshaft. By control of these pressure chamber seat valves, the total displacement are controlled in discrete steps, and the pressure chambers...... not contributing to the displacement are not pressurized, which has been shown to improve the efficiency. To make this type of displacement control possible and energy efficient, the seat valves must be fast switching (ms range) and exhibit a very low pressure loss during operation, setting strict requirements...

  12. Hemodynamic effect and safety of intermittent sequential pneumatic compression leg sleeves in patients with congestive heart failure.

    Science.gov (United States)

    Bickel, Amitai; Shturman, Alexander; Sergeiev, Michael; Ivry, Shimon; Eitan, Arieh; Atar, Shaul

    2014-10-01

    Pneumatic leg sleeves are widely used after prolonged operations for prevention of venous stasis. In healthy volunteers they increase cardiac function. We evaluated the hemodynamic effects and safety of intermittent sequential pneumatic compression (ISPC) leg sleeves in patients with chronic congestive heart failure (CHF). We studied 19 patients with systolic left ventricular dysfunction and CHF. ISPC leg sleeves, each with 10 air cells, were operated by a computerized compressor, exerting 2 cycles/min. Hemodynamic and echocardiographic parameters were measured before, during, and after ISPC activation. The baseline mean left ventricular ejection fraction was 29 ± 9.2%, median 32%, range 10%-40%. Cardiac output (from 4.26 to 4.83 L/min; P = .008) and stroke volume (from 56.1 to 63.5 mL; P = .029) increased significantly after ISPC activation, without a reciprocal increase in heart rate, and declined after sleeve deactivation. Systemic vascular resistance (SVR) decreased significantly (from 1,520 to 1,216 dyne-s/cm5; P = .0005), and remained lower than the baseline level throughout the study. There was no detrimental effect on diastolic function and no adverse clinical events, despite increased pulmonary venous return. ISPC leg sleeves in patients with chronic CHF do not exacerbate symptoms and transiently improve cardiac output through an increase in stroke volume and a reduction in SVR. Copyright © 2014 Elsevier Inc. All rights reserved.

  13. Endoscopic Treatment of Early Gastric Obstruction After Sleeve Gastrectomy: Report of Two Cases

    Directory of Open Access Journals (Sweden)

    Mariana Nuno Costa

    2016-01-01

    Full Text Available Morbid obesity is an epidemic and complex disease which imposes a multidisciplinary approach. Laparoscopic sleeve gastrectomy has become a frequent procedure given its efficacy and safety compared to other surgical options. However, it isn’t free from complications. Lax gastric fixation or incorrect positioning of the stomach during surgery can result in early gastric outlet obstruction caused by a volvulus-like mechanism by rotation of the stomach around its anatomic axes. This report refers to two cases of post sleeve gastric torsion resulting in persisting vomiting after initiating oral intake. The diagnosis was confirmed by upper gastrointestinal-contrast study and gastroscopy. In both cases, a fully covered self-expandable metallic stent was inserted which prompted the gastric lumen to become permeable resulting in symptomatic resolution. The stents were removed endoscopically after two and three months. Beyond more than three years of follow-up, the patients remain asymptomatic and no recurring “stenosis” was noticed. In these cases the use of fully covered self-expandable metallic stents demonstrated to be effective and safe in the treatment of post sleeve gastric torsion.

  14. Performance Evaluation of a High Bandwidth Liquid Fuel Modulation Valve for Active Combustion Control

    Science.gov (United States)

    Saus, Joseph R.; DeLaat, John C.; Chang, Clarence T.; Vrnak, Daniel R.

    2012-01-01

    At the NASA Glenn Research Center, a characterization rig was designed and constructed for the purpose of evaluating high bandwidth liquid fuel modulation devices to determine their suitability for active combustion control research. Incorporated into the rig s design are features that approximate conditions similar to those that would be encountered by a candidate device if it were installed on an actual combustion research rig. The characterized dynamic performance measures obtained through testing in the rig are planned to be accurate indicators of expected performance in an actual combustion testing environment. To evaluate how well the characterization rig predicts fuel modulator dynamic performance, characterization rig data was compared with performance data for a fuel modulator candidate when the candidate was in operation during combustion testing. Specifically, the nominal and off-nominal performance data for a magnetostrictive-actuated proportional fuel modulation valve is described. Valve performance data were collected with the characterization rig configured to emulate two different combustion rig fuel feed systems. Fuel mass flows and pressures, fuel feed line lengths, and fuel injector orifice size was approximated in the characterization rig. Valve performance data were also collected with the valve modulating the fuel into the two combustor rigs. Comparison of the predicted and actual valve performance data show that when the valve is operated near its design condition the characterization rig can appropriately predict the installed performance of the valve. Improvements to the characterization rig and accompanying modeling activities are underway to more accurately predict performance, especially for the devices under development to modulate fuel into the much smaller fuel injectors anticipated in future lean-burning low-emissions aircraft engine combustors.

  15. Development of PZT Actuated Valveless Micropump

    Directory of Open Access Journals (Sweden)

    Fathima Rehana Munas

    2018-04-01

    Full Text Available A piezoelectrically actuated valveless micropump has been designed and developed. The principle components of this system are piezoelectrically actuated (PZT metal diaphragms and a complete fluid flow system. The design of this pump mainly focuses on a cross junction, which is generated by a nozzle jet attached to a pump chamber and the intersection of two inlet channels and an outlet channel respectively. During each PZT diaphragm vibration cycle, the junction connecting the inlet and outlet channels with the nozzle jet permits consistencies in fluidic momentum and resistances in order to facilitate complete fluidic path throughout the system, in the absence of any physical valves. The entire micropump structure is fabricated as a plate-by-plate element of polymethyl methacrylate (PMMA sheets and sandwiched to get required fluidic network as well as the overall device. In order to identify the flow characteristics, and to validate the test results with numerical simulation data, FEM analysis using ANSYS was carried out and an eigenfrequency analysis was performed to the PZT diaphragm using COMSOL Multiphysics. In addition, the control system of the pump was designed and developed to change the applied frequency to the piezoelectric diaphragms. The experimental data revealed that the maximum flow rate is 31.15 mL/min at a frequency of 100 Hz. Our proposed design is not only for a specific application but also useful in a wide range of biomedical applications.

  16. Development of PZT Actuated Valveless Micropump.

    Science.gov (United States)

    Munas, Fathima Rehana; Melroy, Gehan; Abeynayake, Chamitha Bhagya; Chathuranga, Hiniduma Liyanage; Amarasinghe, Ranjith; Kumarage, Pubudu; Dau, Van Thanh; Dao, Dzung Viet

    2018-04-24

    A piezoelectrically actuated valveless micropump has been designed and developed. The principle components of this system are piezoelectrically actuated (PZT) metal diaphragms and a complete fluid flow system. The design of this pump mainly focuses on a cross junction, which is generated by a nozzle jet attached to a pump chamber and the intersection of two inlet channels and an outlet channel respectively. During each PZT diaphragm vibration cycle, the junction connecting the inlet and outlet channels with the nozzle jet permits consistencies in fluidic momentum and resistances in order to facilitate complete fluidic path throughout the system, in the absence of any physical valves. The entire micropump structure is fabricated as a plate-by-plate element of polymethyl methacrylate (PMMA) sheets and sandwiched to get required fluidic network as well as the overall device. In order to identify the flow characteristics, and to validate the test results with numerical simulation data, FEM analysis using ANSYS was carried out and an eigenfrequency analysis was performed to the PZT diaphragm using COMSOL Multiphysics. In addition, the control system of the pump was designed and developed to change the applied frequency to the piezoelectric diaphragms. The experimental data revealed that the maximum flow rate is 31.15 mL/min at a frequency of 100 Hz. Our proposed design is not only for a specific application but also useful in a wide range of biomedical applications.

  17. A COMPUTATIONAL STUDY OF THE ACTUATION SPEED OF THE HYDRAULIC CYLINDER UNDER DIFFERENT PORTS’ SIZES AND CONFIGURATIONS

    Directory of Open Access Journals (Sweden)

    M. O. ABDALLA

    2015-02-01

    Full Text Available The discharged oil from hydraulic cylinder, during its operation, is highly restricted by the small sized outlets. As a result, a back pressure builds up and the piston motion, therefore, is slowed down; the system pump has to do additional work to overcome this hydraulic resistance so as to preserve the required speed. In this study the possibility of improvement of the actuation speed of the hydraulic cylinders was investigated and analysed. Both a four-port cylinder and a resized-ports cylinder were proposed as fast cylinders. FLUENT 6.3 was used for the simulation of the oil flow field of the hydraulic cylinders. Results showed that relation between discharge flow and the outlets diameters is best described by a power law having coefficients partially depending on the system pressure. It had also shown that for any given total outlet area, the actuation speed of the single outlet cylinders is always higher than that of the double outlets cylinders. In one case where the total outlet area is 3.93E-05m2, the actuation speed of the single outlet cylinder is 21% higher than that of the double outlets cylinder; whereas, when doubling the total outlet area the different is reduced to just 6% . Resizing the outlet for small ports was more efficient than using multi-outlets; while for a large ports it shows no significant difference to use either one outlet port or multi-outlets. Both the solutions of resizing or ports addition need special valve to be fit to the cylinder so that the cylinder could be effectively operated under the control of the proportional valve.

  18. Reversible thermo-pneumatic valves on centrifugal microfluidic platforms.

    Science.gov (United States)

    Aeinehvand, Mohammad Mahdi; Ibrahim, Fatimah; Harun, Sulaiman Wadi; Kazemzadeh, Amin; Rothan, Hussin A; Yusof, Rohana; Madou, Marc

    2015-08-21

    Centrifugal microfluidic systems utilize a conventional spindle motor to automate parallel biochemical assays on a single microfluidic disk. The integration of complex, sequential microfluidic procedures on these platforms relies on robust valving techniques that allow for the precise control and manipulation of fluid flow. The ability of valves to consistently return to their former conditions after each actuation plays a significant role in the real-time manipulation of fluidic operations. In this paper, we introduce an active valving technique that operates based on the deflection of a latex film with the potential for real-time flow manipulation in a wide range of operational spinning speeds. The reversible thermo-pneumatic valve (RTPV) seals or reopens an inlet when a trapped air volume is heated or cooled, respectively. The RTPV is a gas-impermeable valve composed of an air chamber enclosed by a latex membrane and a specially designed liquid transition chamber that enables the efficient usage of the applied thermal energy. Inputting thermo-pneumatic (TP) energy into the air chamber deflects the membrane into the liquid transition chamber against an inlet, sealing it and thus preventing fluid flow. From this point, a centrifugal pressure higher than the induced TP pressure in the air chamber reopens the fluid pathway. The behaviour of this newly introduced reversible valving system on a microfluidic disk is studied experimentally and theoretically over a range of rotational frequencies from 700 RPM to 2500 RPM. Furthermore, adding a physical component (e.g., a hemispherical rubber element) to induce initial flow resistance shifts the operational range of rotational frequencies of the RTPV to more than 6000 RPM. An analytical solution for the cooling of a heated RTPV on a spinning disk is also presented, which highlights the need for the future development of time-programmable RTPVs. Moreover, the reversibility and gas impermeability of the RTPV in the

  19. Dynamic load in suppression pool during BWR main steam safety relief valve actuation

    International Nuclear Information System (INIS)

    Tsukada, Hiroshi; Yamaguchi, Hirokatsu; Morita, Terumichi

    1979-01-01

    BWRs are so designed that the exhaust steam from main steam safety relief valves is led to pressure suppression pools, and the steam is condensed in pool water, but at this time, dynamic load seems to arise in the pool water. In Tokai No. 2 Power Station, a Mark-2 containment vessel was adopted to improve the reliability as much as possible and to obtain the design with margin. In this report, the result of actual machine test in Tokai No. 2 Power Station and the method of reducing the load are described. When a relief valve works, the discharge of water in exhaust pipes into a suppression pool, the exhaust of air in exhaust pipes and repeated expansion and contraction of bubbles in pool water, and the exhaust of steam and condensation occur. As for the construction of the suppression pool in Tokai No. 2 Power Station, cross-shaped quencher and the structure with jet deflector were installed. The test plan and the test result with an actual machine are reported. The soundness of the Mark-2 containment vessel and the structures in the pool was proved. The differential pressure acting on the structures was negligibly small. The measured pulsating pressure was in the range from 0.84 to -0.39 kg/cm 2 . (Kako, I.)

  20. Supplement No. 79-01A to IE Bulletin No. 79-01: Environmental qualification of Class 1E equipment (Deficiencies in the environmental qualification of ASCO solenoid valves)

    International Nuclear Information System (INIS)

    Anon.

    1993-01-01

    Recently, a noncompliance report under 10 CFR Part 21 was received by the NRC from the Henry Pratt Company, manufacturer of butterfly valves which are installed in the primary containment at the Three Mile Island Unit 2 Nuclear Station. These butterfly valves are used for purge and exhaust purposes and are required to operate during accident conditions. The report discusses the use of an unqualified solenoid valve for a safety-related valve function which requires operation under accident conditions. The solenoid valve in question is Catalogue No. HT-8331A45, manufactured by the Automatic Switch Company (ASCO) of Florham Park, New Jersey. This pilot valve is used to pilot control the pneumatic valve actuators which are installed on the containment ventilation butterfly valves at this facility. The deficiency in these solenoid valves identified in the Part 21 Report concerns the parts made of acetal plastic material. The acetal disc holder assembly and bottom plug in the pilot valve assembly are stated by ASCO to have a maximum service limit of 400,000 Rad integrated dosage and 200 degrees F temperature. According to ASCO, exposure of these acetal plastic parts to specified maximum environmental conditions may render the solenoid pilot valve inoperable which would cause the associated butterfly valve to malfunction

  1. Bi-directional series-parallel elastic actuator and overlap of the actuation layers.

    Science.gov (United States)

    Furnémont, Raphaël; Mathijssen, Glenn; Verstraten, Tom; Lefeber, Dirk; Vanderborght, Bram

    2016-01-27

    Several robotics applications require high torque-to-weight ratio and energy efficient actuators. Progress in that direction was made by introducing compliant elements into the actuation. A large variety of actuators were developed such as series elastic actuators (SEAs), variable stiffness actuators and parallel elastic actuators (PEAs). SEAs can reduce the peak power while PEAs can reduce the torque requirement on the motor. Nonetheless, these actuators still cannot meet performances close to humans. To combine both advantages, the series parallel elastic actuator (SPEA) was developed. The principle is inspired from biological muscles. Muscles are composed of motor units, placed in parallel, which are variably recruited as the required effort increases. This biological principle is exploited in the SPEA, where springs (layers), placed in parallel, can be recruited one by one. This recruitment is performed by an intermittent mechanism. This paper presents the development of a SPEA using the MACCEPA principle with a self-closing mechanism. This actuator can deliver a bi-directional output torque, variable stiffness and reduced friction. The load on the motor can also be reduced, leading to a lower power consumption. The variable recruitment of the parallel springs can also be tuned in order to further decrease the consumption of the actuator for a given task. First, an explanation of the concept and a brief description of the prior work done will be given. Next, the design and the model of one of the layers will be presented. The working principle of the full actuator will then be given. At the end of this paper, experiments showing the electric consumption of the actuator will display the advantage of the SPEA over an equivalent stiff actuator.

  2. Soft, Rotating Pneumatic Actuator.

    Science.gov (United States)

    Ainla, Alar; Verma, Mohit S; Yang, Dian; Whitesides, George M

    2017-09-01

    This article describes a soft pneumatic actuator that generates cyclical motion. The actuator consists of several (three, four, or five) chambers (arranged around the circumference of a circle surrounding a central rod) that can be actuated independently using negative pressure (or partial vacuum). Sequential actuation of the four-chamber device using reduced pressure moves the central rod cyclically in an approximately square path. We characterize the trajectory of the actuator and the force exerted by it, as we vary the material used for fabrication, the number of chambers, and the size of the actuator. We demonstrate two applications of this actuator: to deliver fluid while stirring (by replacing the central rod with a needle) and for locomotion that mimics a reptilian gait (by combining four actuators together).

  3. Duodenal-jejunal bypass sleeve - a potential alternative to bariatric surgery?

    DEFF Research Database (Denmark)

    Rohde, Ulrich; Gylvin, Silas; Vilmann, Peter

    2014-01-01

    Overweight and obesity are risk factors for several co-morbidities reducing life expectancy. Conservative treatment of obesity is generally ineffective in the long-term. Bariatric surgery has proven effective, but is associated with potential complications. Duodenal-jejunal bypass sleeve is a novel...

  4. Association between postprandial symptoms and gastric emptying after sleeve gastrectomy

    NARCIS (Netherlands)

    Burgerhart, Jan S.; van Rutte, Pim W. J.; Edelbroek, Michela A. L.; Wyndaele, Dirk N. J.; Smulders, Johannes F.; van de Meeberg, Paul C.; Siersema, Peter D.; Smout, André J. P. M.

    2015-01-01

    Laparoscopic sleeve gastrectomy (LSG) is an effective bariatric procedure. However, postprandial symptoms can compromise its beneficial effect. It is not known if a changed gastric emptying and these symptoms are related. This study aimed to assess the association between postprandial symptoms and

  5. Soft buckling actuators

    Energy Technology Data Exchange (ETDEWEB)

    Yang, Dian; Whitesides, George M.

    2017-12-26

    A soft actuator is described, including: a rotation center having a center of mass; a plurality of bucklable, elastic structural components each comprising a wall defining an axis along its longest dimension, the wall connected to the rotation center in a way that the axis is offset from the center of mass in a predetermined direction; and a plurality of cells each disposed between two adjacent bucklable, elastic structural components and configured for connection with a fluid inflation or deflation source; wherein upon the deflation of the cell, the bucklable, elastic structural components are configured to buckle in the predetermined direction. A soft actuating device including a plurality of the soft actuators and methods of actuation using the soft actuator or soft actuating device disclosed herein are also described.

  6. The weight is over: RN first assisting techniques for laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Wentzell, Joanne; Neff, Marc

    2015-08-01

    Obesity-related laparoscopic sleeve gastrectomy is a common yet technically challenging bariatric procedure that requires specialized surgical knowledge and training for OR personnel. Critical components of care include an effective preoperative assessment, positioning of the patient, and operation and maintenance of laparoscopic equipment and instrumentation. The purpose of this article is to explain the steps of laparoscopic sleeve gastrectomy and illustrate principles and surgical techniques for the RN who is first assisting during the procedure. Also provided is a perioperative nursing care plan for the patient undergoing bariatric surgery, to aid perioperative nurses in understanding the sequence of events and special considerations for this patient population. Copyright © 2015 AORN, Inc. Published by Elsevier Inc. All rights reserved.

  7. Internal leakage detection in control valves; Detektion der inneren Leckage von Stellgeraeten

    Energy Technology Data Exchange (ETDEWEB)

    Kiesbauer, J. [SAMSON AG, Mess- und Regeltechnik, Frankfurt am Main (Germany). Entwicklungspruefstand; Hoffmann, H. [SAMSON AG, Mess- und Regeltechnik, Frankfurt am Main (Germany). Bereich Entwicklung

    2000-07-01

    Digital positioners offer a number of interesting features regarding improved process plant reliability and maintenance or servicing. This can provide the basis for using software tools for early fault diagnosis and performance visualization of control valves with extended functions, such as archiving the control valve's condition when new. It can be subjected to trend analyses as well as to preventative maintenance and servicing while in operation. Up to now, such systems cannot reliably predict the possible increase in internal leakage. Predictions can only be made about a possible change in the actuator's closing force and the zero point when the valve is closed. This article introduces a new and cost-effective leakage detector for control valves in combination with the binary input of a digital positioner which can signal the increase in internal leakage in the throttling area (e.g. caused by wear on the throttling element) of a control valve, if the valve is closed during operation. (orig.) [German] Digitale Stellungsregler bieten eine Reihe von interessanten Moeglichkeiten im Hinblick auf die Verbesserung der Prozesszuverlaessigkeit und der Wartung bzw. Instandhaltung. Auf dieser Basis koennen Softwaretools zur Fehlerfrueherkennung und zur Performance-Visualisierung bei Stellgeraeten mit weitergehender Funktionalitaet eingesetzt werden. Diese unterstuetzen z.B. die Archivierung des Neuzustandes des Stellgeraetes sowie die vorbeugende Wartung und Instandhaltung im laufenden Prozess bis hin zu Trendanalysen. Solche Systeme koennen bisher allerdings noch keine zuverlaessigen Aussagen ueber die eventuelle Zunahme der inneren Leckage machen. Aussagen sind nur moeglich ueber eventuelle Veraenderungen der Antriebsschliesskraft und des Nullpunktes bei geschlossenem Ventil. Dieser Beitrag stellt einen neuartigen kostenguenstigen Leckagedetektor fuer Stellgeraete in Kombination mit dem Binaereingang eines digitalen Stellungsreglers vor, welcher die erhoehte

  8. Early Laparoscopic Sleeve Gastrectomy Outcomes in Terms of Weight Loss

    International Nuclear Information System (INIS)

    Siddiq, G.; Aziz, W.; Pervez, M. B.; Haider, M. I.; Hussain, S. V.; Khan, N.

    2016-01-01

    Objective: To investigate the outcomes of laparoscopic sleeve gastrectomy (LSG) in terms of weight loss. Study Design: Descriptive cohort study. Place and Duration of Study: Department of Surgery, Shifa International Hospital, Islamabad, from January 2009 to January 2015. Methodology: A total of 100 consecutive patients were included in the study through retrospective chart review. A 5-port technique was utilized with the gastric sleeve being created using endostapler. Postoperatively, patients gradually progressed from clear liquid diet and oral rehydration salts to nutritional supplements over three days. By two weeks postoperatively, patients had progressed to a solid diet. SPSS was used for data entry and analysis. Body mass index (BMI) and weight in kg were determined. Results: From 100 patients, 17 were lost to follow-up less than a week into the postoperative period. Of the remaining, average age of the patients was 34.7 ±11.3 years at the time of surgery. The majority of patients were females (72 percentage). Mean preoperative and postoperative BMI was 45.3 ±10.4 kg/m2 and 35.0 ±10 kg/m2, respectively. Of the 83 patients, 62 were followed-up for longer than 1 month (average 419 days). For patients in this category, mean reduction in BMI was 10.3 ±6.5 kg/m2 with average weight loss of 34.3 ±18.2 kg. There were no mortalities associated with LSG. Conclusion: Laparoscopic sleeve gastrectomy is a safe and effective intervention in young Pakistani females with encouraging outcomes at a mean follow-up of over one year. (author)

  9. Laparoscopic sleeve gastrectomy for morbid obesity with natural orifice specimen extraction (NOSE).

    Science.gov (United States)

    Gunkova, P; Gunka, I; Zonca, P; Dostalik, J; Ihnat, P

    2015-01-01

    An experience with laparoscopic sleeve gastrectomy using the natural orifice specimen extraction (NOSE) technique. Bariatric surgery is nowadays the only long term effective obesity treatment method. Twenty one consecutive patients underwent laparoscopic sleeve gastrectomy with the use of natural orifice specimen extraction (NOSE) in the Surgical Clinic of Faculty Hospital Ostrava between May 2012 and August 2012. Inclusion criteria were the body mass index (BMI) higher than 35 kg/m2 or higher than 32 kg/m2 accompanied with relevant comorbidities. Among 21 patients in this series, there were three men (14.3%) and 18 women (85.7%). Their mean age was 40.9±10.2 years. Their mean preoperative BMI was 40.4±4.6 kg/m2. No patient had previous bariatric surgery, one patient had laparoscopic fundoplication. All operations were completed laparoscopically with no conversions to an open procedure. In two cases, laparoscopic cholecystectomy was performed and the gallbladder was extracted along with the gastric specimen by transgastric approach. Laparoscopic sleeve gastrectomy is a safe and effective bariatric procedure with low morbidity and mortality. Based on our initial experiences it could be an indication for NOSE with transgastric approach. Obese patients would benefit from this approach due to the elimination of wound complications (Tab. 2, Fig. 3, Ref. 22).

  10. Heart valve surgery

    Science.gov (United States)

    ... replacement; Valve repair; Heart valve prosthesis; Mechanical valves; Prosthetic valves ... surgery. Your heart valve has been damaged by infection ( endocarditis ). You have received a new heart valve ...

  11. Crygenic performance of a superfluid helium relief valve for the LHC superconducting magnets

    International Nuclear Information System (INIS)

    Danielsson, H.; Ferlin, G.; Luguet, C.

    1996-01-01

    The high-field superconducting magnets of the Large Hadron Collider (LHC) project at CERN will operate below 1.9 K in static baths of pressurized helium II. In case of resistive transition (open-quotes quenchclose quotes), the resulting pressure rise in the cryostats must be limited to below their 2 MPa design pressure. This is achieved by discharging helium at high flow-rates into a cold recovery header, normally maintained at 20 K. For this purpose, the authors have designed, built and tested a cryogenic quench relief valve with a nominal diameter of 50 mm and an opening time of below 0.1 s. The valve, which can be opened on an external trigger, also acts as a relief device actuated by the upstream pressure when it exceeds 0.4 MPa. In normal operation, the closed poppet must be helium-tight, for hydraulic and thermal separation of the magnet baths from the recovery header. Following mechanical qualification tests under vacuum, the authors have mounted the relief valve in a dedicated cryogenic measuring bench, in order to perform precision thermal measurements with pressurized helium II

  12. Anticorrosive field joint coating qualification, heat shrinkable sleeve; Qualificacao de revestimento anticorrosivo para juntas de campo, mantas termocontrateis

    Energy Technology Data Exchange (ETDEWEB)

    Cabral, Glaucia B.; Koebsch, Andre; Castinheiras Junior, Wilson [PETROBRAS, Rio de Janeiro, RJ (Brazil)

    2005-07-01

    The main objective of this job is to present the quality requirements fixed by PETROBRAS for anticorrosive field joint coating for buried pipelines, industrially coated with PE-3L. It describes the used system - polyethylene based heat shrinkable sleeve - comparing with the existent on the pipeline. So, it exposes the suppliers' qualification stages, which include test carried out for the materials, for the sleeve set and for the coating after its application on the joint field. Finally, it shows that the experience, which has been gotten in the qualification, consolidated the quality control systematic that have been carry out during the sleeves acquisition and application at the pipeline construction. (author)

  13. Laparoscopic hand-assisted versus robotic-assisted laparoscopic sleeve gastrectomy: experience of 103 consecutive cases.

    Science.gov (United States)

    Kannan, Umashankkar; Ecker, Brett L; Choudhury, Rashikh; Dempsey, Daniel T; Williams, Noel N; Dumon, Kristoffel R

    2016-01-01

    Laparoscopic sleeve gastrectomy has become a stand-alone procedure in the treatment of morbid obesity. There are very few reports on the use of robotic approach in sleeve gastrectomy. The purpose of this retrospective study is to report our early experience of robotic-assisted laparoscopic sleeve gastrectomy (RALSG) using a proctored training model with comparison to an institutional cohort of patients who underwent laparoscopic hand-assisted sleeve gastrectomy (LASG). University hospital. The study included 108 patients who underwent sleeve gastrectomy either via the laparoscopic-assisted or robot-assisted approach during the study period. Of these 108 patients, 62 underwent LASG and 46 underwent RALSG. The console surgeon in the RALSG is a clinical year 4 (CY4) surgery resident. All CY4 surgery residents received targeted simulation training before their rotation. The console surgeon is proctored by the primary surgeon with assistance as needed by the second surgeon. The patients in the robotic and laparoscopic cohorts did not have a statistical difference in their demographic characteristics, preoperative co-morbidities, or complications. The mean operating time did not differ significantly between the 2 cohorts (121 min versus 110 min, P = .07). Patient follow-up in the LSG and RALSG were 91% and 90% at 3 months, 62% and 64% at 6 months, and 60% and 55% at 1 year, respectively. The mean percentage estimated weight loss (EWL%) at 3 months, 6 months, and 1 year was greater in the robotic group but not statistically significant (27 versus 22 at 3 mo [P = .05] and 39 versus 34 at 6 mo [P = .025], 57 versus 48 at 1 yr [P = .09]). There was no mortality in either group. Early results of our experience with RALSG indicate low perioperative complication rates and comparable weight loss with LASG. The concept of a stepwise education model needs further validation with larger studies. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc

  14. A Wideband Dual-Polarized Antenna Using Planar Quasi-Open-Sleeve Dipoles for Base Station Applications

    Directory of Open Access Journals (Sweden)

    Guan-xi Zhang

    2015-01-01

    Full Text Available A wideband dual-polarized antenna for WLAN, WiMAX, and LTE base station applications is presented in this paper. The proposed antenna consists of two pairs of orthogonal planar quasi-open-sleeve dipoles along the centerlines, a balanced feeding structure and a square ground plane. The planar quasi-open-sleeve dipole comprises a pair of bowtie-shaped planar dipoles with two parallel curve parasitic elements. The introduced parallel curve parasitic elements change the path of the current of the original bowtie-shaped planar dipoles at high frequencies and hence wideband characteristic is achieved. Two pairs of the planar quasi-open-sleeve dipoles placed orthogonally further broaden the bandwidth of the antenna with dual-polarization characteristics. The proposed antenna achieves a 10-dB return loss bandwidth from 2.32 to 4.03 GHz (53.9% bandwidth using the planar quasi-open-sleeve dipole structures. The isolation between the two ports remains more than 32 dB in the whole bandwidth. Measured results show that the proposed antenna keeps the cross-polarization under −33 dB and the front-to-back ratio better than 15 dB in the operating band. The antenna has an area of 0.3λ  × 0.3λ at 2.32 GHz making it easy to be extended to an array element.

  15. Modified sleeve anastomosis for reconstruction of the hepatic artery in rat liver transplantation.

    Science.gov (United States)

    Li, Jun; Dahmen, Uta; Dirsch, Olaf; Shen, Kai; Gu, Yanli; Broelsch, Christoph Erich

    2002-01-01

    End-to-end sleeve anastomosis between a donor common hepatic artery and a recipient proper hepatic artery was proven to be the most physiological and simple method for hepatic rearterialization in rat liver transplantation. Current technical variants of the sleeve technique, however, are hampered by the high rate of bleeding from the anastomotic site. This report deals with a technical modification which inhibits postoperative bleeding efficiently. The procedure consisted of a guiding suture, as previously described in other technical variants, and a modified fixing suture. Instead of using a single stitch to fix the feeding vessel with the receiving vessel, a running suture between the edge of the donor common hepatic artery and the adventitia of the recipient proper hepatic artery was performed to avoid a possible backflow. The patency rate of 91% was as high as reported by others using a sleeve technique, which was also reflected in the histomorphological picture, being indistinguishable from normal liver histology. This technical modification simplified the procedure of reconstructing the hepatic artery and could contribute to a wider use of the arterialized liver transplantation model in rats. Copyright 2002 Wiley-Liss, Inc.

  16. Role of passive valves & devices in poison injection system of advanced heavy water reactor

    International Nuclear Information System (INIS)

    Sapra, M.K.; Kundu, S.; Vijayan, P.K.; Vaze, K.K.; Sinha, R.K.

    2014-01-01

    The Advanced Heavy Water Reactor (AHWR) is a 300 MWe pressure tube type boiling light water (H 2 O) cooled, heavy water (D 2 O) moderated reactor. The reactor design is based on well-proven water reactor technologies and incorporates a number of passive safety features such as natural circulation core cooling; direct in-bundle injection of light water coolant during a Loss of Coolant Accident (LOCA) from Advanced Accumulators and Gravity Driven Water Pool by passive means; Passive Decay Heat Removal using Isolation Condensers, Passive Containment Cooling System and Passive Containment Isolation System. In addition to above, there is another passive safety system named as Passive Poison Injection System (PPIS) which is capable of shutting down the reactor for a prolonged time. It is an additional safety system in AHWR to fulfill the shutdown function in the event of failure of wired shutdown systems i.e. primary and secondary shut down systems of the reactor. When demanded, PPIS injects the liquid poison into the moderator by passive means using passive valves and devices. On increase of main heat transport (MHT) system pressure beyond a predetermined value, a set of rupture disks burst, which in-turn actuate the passive valve. The opening of passive valve initiates inrush of high pressure helium gas into poison tanks to push the poison into the moderator system, thereby shutting down the reactor. This paper primarily deals with design and development of Passive Poison Injection System (PPIS) and its passive valves & devices. Recently, a prototype DN 65 size Poison Injection Passive Valve (PIPV) has been developed for AHWR usage and tested rigorously under simulated conditions. The paper will highlight the role of passive valves & devices in PPIS of AHWR. The design concept and test results of passive valves along with rupture disk performance will also be covered. (author)

  17. Acute Pancreatitis with Splenic Infarction as Early Postoperative Complication following Laparoscopic Sleeve Gastrectomy

    Directory of Open Access Journals (Sweden)

    Aleksandr Kalabin

    2017-01-01

    Full Text Available Obesity is becoming a global health burden along with its comorbidities. It imposes tremendous financial burden and health costs worldwide. Surgery has emerged as the definitive treatment option for morbidly obese patients with comorbidities. Laparoscopic sleeve gastrectomy is performed now more than ever making it imperative for physicians and surgeons to recognize both the common and the uncommon risks and complications associated with it. In this report we describe a rare early life-threatening postoperative complication following laparoscopic sleeve gastrectomy. From our extensive review of literature, there is no existing report of acute pancreatitis with splenic infarction postsleeve gastrectomy to this date.

  18. Experimental and numerical study of steel pipe with part-wall defect reinforced with fibre glass sleeve

    International Nuclear Information System (INIS)

    Mazurkiewicz, Lukasz; Tomaszewski, Michal; Malachowski, Jerzy; Sybilski, Kamil; Chebakov, Mikhail; Witek, Maciej; Yukhymets, Peter; Dmitrienko, Roman

    2017-01-01

    The paper presents numerical and experimental burst pressure evaluation of the gas seamless hot-rolled steel pipe. The main goal was to estimate mechanical toughness of pipe wrapped with composite sleeve and verify selected sleeve thickness. The authors used a nonlinear explicit FE code with constitutive models which allows for steel and composite structure failure modelling. Thanks to the achieved numerical and analytical results it was possible to perform the comparison with data received from a capacity test and good correlation between the results were obtained. Additionally, the conducted analyses revealed that local reduction of pipe wall thickness from 6 mm to 2.4 mm due to corrosion defect can reduce high pressure resistance by about 40%. Finally, pipe repaired by a fibre glass sleeve with epoxy resin with 6 mm thickness turned out more resistant than an original steel pipe considering burst pressure. - Highlights: • Numerical and experimental burst pressure evaluation of steel pipe was performed. • Seamless hot-rolled steel pipe with and without corrosion defect were considered. • Local reduction of pipe wall thickness from 6 to 2.4 mm reduces resistance by 40%. • Pipe repaired by a 6 mm fibre glass sleeve was more resistant than an original pipe.

  19. Bioprosthetic Valve Fracture During Valve-in-valve TAVR: Bench to Bedside.

    Science.gov (United States)

    Saxon, John T; Allen, Keith B; Cohen, David J; Chhatriwalla, Adnan K

    2018-01-01

    Valve-in-valve (VIV) transcatheter aortic valve replacement (TAVR) has been established as a safe and effective means of treating failed surgical bioprosthetic valves (BPVs) in patients at high risk for complications related to reoperation. Patients who undergo VIV TAVR are at risk of patient-prosthesis mismatch, as the transcatheter heart valve (THV) is implanted within the ring of the existing BPV, limiting full expansion and reducing the maximum achievable effective orifice area of the THV. Importantly, patient-prosthesis mismatch and high residual transvalvular gradients are associated with reduced survival following VIV TAVR. Bioprosthetic valve fracture (BVF) is as a novel technique to address this problem. During BPV, a non-compliant valvuloplasty balloon is positioned within the BPV frame, and a highpressure balloon inflation is performed to fracture the surgical sewing ring of the BPV. This allows for further expansion of the BPV as well as the implanted THV, thus increasing the maximum effective orifice area that can be achieved after VIV TAVR. This review focuses on the current evidence base for BVF to facilitate VIV TAVR, including initial bench testing, procedural technique, clinical experience and future directions.

  20. Pressurizer safety valve serviceability enhancement by spring compression stability

    Energy Technology Data Exchange (ETDEWEB)

    Ratiu, M.D.; Moisidis, N.T. [California Consulting Engineering and Technology (CALCET), San Leandro, California (United States)

    2007-07-01

    The proactive maintenance of the spring-loaded-self-actuated Pressurizer Safety Valve (PSV) has caused frequent concerns pertaining the spring self actuated reliability due to set point drift, spurious openings, and seat leakage. The exhaustive testing performed on a Crosby PSV model 6M6 has revealed that the principal cause of these malfunctions is the spring compression elastic instability during service. The spring lateral deformations measurements performed validated the analytical shapes for spring compression: symmetrical bending - for coaxial supported ends - restraining any support displacement, and asymmetrical bending induced by the potential misalignment of the supported top end. The source of the spring compression instability appears on the tested Crosby PSV induced by the top end lateral displacement during long term operation. The testing with restrained displacement at the spring top has shown consistent set-point reproducibility, less than +/- 1 per cent. To eliminate the asymmetrical spring buckling, a design review of the PSV is proposed including the guided fixture at the top and the decrease of spring coil slenderness ratio H/D, corresponding to the general analytical elastic stability for the asymmetrical compression. (authors)

  1. Pressurizer safety valve serviceability enhancement by spring compression stability

    International Nuclear Information System (INIS)

    Ratiu, M.D.; Moisidis, N.T.

    2007-01-01

    The proactive maintenance of the spring-loaded-self-actuated Pressurizer Safety Valve (PSV) has caused frequent concerns pertaining the spring self actuated reliability due to set point drift, spurious openings, and seat leakage. The exhaustive testing performed on a Crosby PSV model 6M6 has revealed that the principal cause of these malfunctions is the spring compression elastic instability during service. The spring lateral deformations measurements performed validated the analytical shapes for spring compression: symmetrical bending - for coaxial supported ends - restraining any support displacement, and asymmetrical bending induced by the potential misalignment of the supported top end. The source of the spring compression instability appears on the tested Crosby PSV induced by the top end lateral displacement during long term operation. The testing with restrained displacement at the spring top has shown consistent set-point reproducibility, less than +/- 1 per cent. To eliminate the asymmetrical spring buckling, a design review of the PSV is proposed including the guided fixture at the top and the decrease of spring coil slenderness ratio H/D, corresponding to the general analytical elastic stability for the asymmetrical compression. (authors)

  2. Simulation model of an electrohydraulic-actuated double-clutch transmission vehicle: modelling and system design

    Science.gov (United States)

    Schoeftner, J.; Ebner, W.

    2017-12-01

    Automated and manual transmissions are the main link between engine and powertrain. The technical term when the transmission provides the desired torque during all possible driving conditions is denoted as powertrain matching. Recent developments in the last years show that double-clutch-transmissions (DCTs) are a reasonable compromise in terms of production costs, shifting quality, drivability and fuel efficiency. They have several advantages compared to other automatic transmissions (AT). Most DCTs nowadays consist of a hydraulic actuation control unit, which controls the clutches of the gearbox in order to induce a desired drivetrain torque into the driveline. The main functions of hydraulic systems are manifold: they initiate gear shifts, they provide sufficient oil for lubrication and they control the shift quality by suitably providing a desired oil flow or pressure for the clutch actuation. In this paper, a mathematical model of a passenger car equipped with a DCT is presented. The objective of this contribution is to get an increased understanding for the dynamics of the hydraulic circuit and its coupling to the vehicle drivetrain. The simulation model consists of a hydraulic and a mechanical domain: the hydraulic actuation circuit is described by nonlinear differential equations and includes the dynamics of the line pressure and the proportional valve, as well as the influence of the pressure reducing valve, pipe resistances and accumulator dynamics. The drivetrain with its gear ratios, moments of inertia, torsional stiffness of the rotating shafts and a simple longitudinal vehicle model represent the mechanical domain. The link between hydraulic and mechanical domain is given by the clutch, which combines hydraulic equations and Newton's laws. The presented mathematical model may not only be used as a simulation model for developing the transmission control software, it may also serve as a virtual layout for the design process phase. At the end of this

  3. Multifunctional four-port directional control valve constructed from logic valves

    International Nuclear Information System (INIS)

    Lisowski, E.; Czyżycki, W.; Rajda, J.

    2014-01-01

    Highlights: • Directional valve with standard ISO 440-08 has been constructed from logic valves. • Only one innovative valve may replace whole family of the standard valves. • CFD analysis and bench tests of the innovative valve has been carried. • Parameters of the innovative valve are equaling or surpassing the standard ones. • The innovative valve has additional possibilities of pressure and flow control. - Abstract: The paper refers to four-port solenoid pilot operated valves, which are subplate mounted in a hydraulic system in accordance with the ISO 4401 standard. Their widespread use in many machines and devices causes a continuing interest in the development of their design by both the scientific centers and the industry. This paper presents an innovative directional control valve based on the use of logic valves and a methodology followed for the design of it by using Solid Edge CAD and ANSYS/Fluent CFD software. The valve design methodology takes into account the need to seek solutions that minimize flow resistance through the valve. For this purpose, the flow paths are prepared by means of CAD software and pressure-flow curves are determined as a result of CFD analysis. The obtained curves are compared with the curves available in the catalogs of spool type directional control valves. The new solution allows to replace the whole family of spool type four-port directional control valves by one valve built of logic valves. In addition, the innovative directional control valve provides leak-proof shutting the flow paths off and also it can control flow rate and even pressure of working liquid. A prototype of the valve designed by the presented method has been made and tested on the test bench. The results quoted in the paper confirm that the developed logic type directional control valve is able to meet all designed connection configurations, and the obtained pressure-flow curves show very good conformity with the results of CFD analysis

  4. The effective neutron temperature in heated graphite sleeves

    Energy Technology Data Exchange (ETDEWEB)

    Shaw, J A; Small, V G [General Reactor Physics Division, Atomic Energy Establishment, Winfrith, Dorchester, Dorset (United Kingdom)

    1963-08-15

    In a series of oscillator measurements carried out in the reactor NERO the variation of the relative reaction rates of cadmium and boron absorbers has been used to determine the effective neutron temperature inside heated graphite sleeves. This work extends the scope of similar oscillator measurements previously carried out in DIMPLE, in that the bulk moderator is now graphite as opposed to D{sub 2}O in the former case. (author)

  5. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy

    Directory of Open Access Journals (Sweden)

    Ying-Nan Tsai

    2018-01-01

    Full Text Available Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG (n = 5 and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG (n = 2. A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks.

  6. Endoluminal stenting for the management of leak following sleeve gastrectomy and loop duodenojejunal bypass with sleeve gastrectomy.

    Science.gov (United States)

    Tsai, Ying-Nan; Wang, Hsiu-Po; Huang, Chih-Kun; Chang, Po-Chin; Lin, I-Chang; Tai, Chi-Ming

    2018-01-01

    Postoperative leak is a serious complication of bariatric surgery and often results in significant morbidity and mortality. Stent placement is a less invasive alternative to surgery for the treatment of bariatric surgical leak. We evaluated the efficacy and complications of covered self-expandable metal stents (SEMS) in the treatment of post-bariatric surgical leak. We retrospectively reviewed patients who underwent stent placement for leak after bariatric surgery. Leak was diagnosed by upper gastrointestinal series or was visualized during the endoscopy. We examined the timing of stent placement, size of the leak, stent migration and its complications, total stent treatment duration, and treatment outcome. Between January 2011 and April 2015, seven patients underwent covered SEMS placement for leak after bariatric surgery, including laparoscopic sleeve gastrectomy (LSG) (n = 5) and laparoscopic loop duodenojejunal bypass with sleeve gastrectomy (LDJB-SG) (n = 2). A stent was placed in one patient for infection control and bridging to revisional surgery. Among the other six patients, one patient who received stent placement one year after leak diagnosis failed to achieve leak closure, and five patients with early stent placement achieved leak closure. Three patients with small leak achieved leak closure more quickly. Stent migration was found in six patients, and associated ulcers occurred in five patients. We conclude that stenting is effective in the management of staple-line leaks following LSG and LDJB-SG. Stent migration and associated ulcers are common after stent placement. Early stent removal can be achieved in patients with small leaks. Copyright © 2017. Published by Elsevier Taiwan.

  7. Math Machines: Using Actuators in Physics Classes

    Science.gov (United States)

    Thomas, Frederick J.; Chaney, Robert A.; Gruesbeck, Marta

    2018-01-01

    Probeware (sensors combined with data-analysis software) is a well-established part of physics education. In engineering and technology, sensors are frequently paired with actuators—motors, heaters, buzzers, valves, color displays, medical dosing systems, and other devices that are activated by electrical signals to produce intentional physical change. This article describes how a 20-year project aimed at better integration of the STEM disciplines (science, technology, engineering and mathematics) uses brief actuator activities in physics instruction. Math Machines "actionware" includes software and hardware that convert virtually any free-form, time-dependent algebraic function into the dynamic actions of a stepper motor, servo motor, or RGB (red, green, blue) color mixer. With wheels and a platform, the stepper motor becomes LACI, a programmable vehicle. Adding a low-power laser module turns the servo motor into a programmable Pointer. Adding a gear and platform can transform the Pointer into an earthquake simulator.

  8. Control Valve

    Energy Technology Data Exchange (ETDEWEB)

    Moore, Wayne R.

    2018-03-20

    A control valve includes a first conduit having a first inlet and a first outlet and defining a first passage; a second conduit having a second inlet and a second outlet and defining a second passage, the second conduit extending into the first passage such that the second inlet is located within the first passage; and a valve plate disposed pivotably within the first passage, the valve plate defining a valve plate surface. Pivoting of the valve plate within the first passage varies flow from the first inlet to the first outlet and the valve plate is pivotal between a first position and a second position such that in the first position the valve plate substantially prevents fluid communication between the first passage and the second passage and such that in the second position the valve plate permits fluid communication between the first passage and the second passage.

  9. Ex-vivo release of Pipeline Embolization Device polytetrafluoroethylene (PTFE) sleeves for improved distal landing zone accuracy in-vivo: A technical note.

    Science.gov (United States)

    Griessenauer, Christoph J; Gupta, Raghav; Moore, Justin; Thomas, Ajith J; Ogilvy, Christopher S

    2016-12-01

    Distal landing zone accuracy is critical in some intracranial aneurysms treated with the Pipeline Embolization Device (PED), and delayed opening of the distal end of the device can complicate the procedure. Here, we report a technical nuance that facilitates accurate placement of the distal end of the PED by ex-vivo, pre-implantation release of the PED Flex polytetrafluoroethylene (PTFE) sleeves. The PED Flex is partially pushed out of the introducer sheath ex-vivo, pre-implantation until the distal PED opens entirely and the PTFE sleeves are located distal to the device. Without inverting the PTFE sleeves, the PED is carefully pulled back into the introducer sheath placing the PTFE sleeves inside the device. The PED is loaded into the microcatheter and advanced toward the site of implantation. When the PED is initially deployed and pushed out of the microcatheter, it opens immediately and provides an anchor for the remainder of the deployment process. We present a video (supplementary material) that illustrates the technique along with an illustrative case. Ex-vivo, pre-implantation release of the PTFE sleeves is an option in aneurysm treatment where distal landing accuracy is critical. Even without the protection of the PTFE sleeves, our clinical observation shows that the PED can be advanced safely through the microcatheter in selected cases. © The Author(s) 2016.

  10. Modeling and design of a tendon actuated soft robotic exoskeleton for hemiparetic upper limb rehabilitation.

    Science.gov (United States)

    Nycz, Christopher J; Delph, Michael A; Fischer, Gregory S

    2015-01-01

    Robotic technology has recently been explored as a means to rehabilitate and assist individuals suffering from hemiparesis of their upper limbs. Robotic approaches allow for targeted rehabilitation routines which are more personalized and adaptable while providing quantitative measurements of patient outcomes. Development of these technologies into inherently safe and portable devices has the potential to extend the therapy outside of the clinical setting and into the patient's home with benefits to the cost and accessibility of care. To this end, a soft, cable actuated robotic glove and sleeve was designed, modeled, and constructed to provide assistance of finger and elbow movements in a way that mimics the biological function of the tendons. The resulting design increases safety through greater compliance as well as greater tolerance for misalignment with the user's skeletal frame over traditional rigid exoskeletons. Overall this design provides a platform to expand and study the concepts around soft robotic rehabilitation.

  11. Long term (7 or more years) outcomes of the sleeve gastrectomy: a meta-analysis.

    Science.gov (United States)

    Clapp, Benjamin; Wynn, Matthew; Martyn, Colin; Foster, Chase; O'Dell, Montana; Tyroch, Alan

    2018-03-06

    The laparoscopic sleeve gastrectomy is now the most common bariatric operation in the United States and has become an established procedure in the armamentarium of the bariatric surgeon. However, this has happened without the strong support of long-term outcomes data, namely the rate of revision and durability of the weight loss. Newly published data from around the world are starting to show alarming trends in these 2 areas. This paper will examine the published and presented data with at least a 7-year follow-up. This is a meta-analysis on published data with at least 7 years of follow-up from the laparoscopic sleeve gastrectomy. Online published articles. We performed a meta-analysis of publications with at least 7 years of follow-up with the keywords "laparoscopic, bariatric, sleeve gastrectomy, sleeve, long-term, long, term, results, follow-up, follow up, conversion, 7 years, 8 years, 9 years, 10 years, 11 years." We queried the PubMed, MEDLINE, and ClinicalKey search engines, which included abstracts as well. The I 2 statistic was used to determine the heterogeneity across the studies. In presence of heterogeneity, a random effect model using the Dersimonian and Laird method was used to estimate the pooled estimates. The results were summarized using effect size along with a 95% confidence interval (CI). Meta-regression was also used to assess the effect of body mass index and follow-up years on the incidence of recidivism at ≥7 years. Nine cohort studies met the inclusion criteria, with a total of 2280 patients included initially. Only 652 patients had completed ≥7 years of follow-up. At ≥7 years, the long-term weight recidivism rate was estimated to be 27.8% (I 2 = .60%; 95% CI: 22.8%-32.7%) with a range of 14% to 37%. The overall revision rate was estimated to be 19.9% (I 2 = 93.8%; 95% CI: 11.3%-28.5%). This was broken down into 13.1% (I 2 = 93.8%; 95% CI: 5.6%-20.6%) due to weight regain (5 studies) and 2.9% (I 2 = 60.8%; 95% CI: 1%-4.9%) due to

  12. Characterization of kink actuators as compared to traditional chevron shaped Bent-Beam electrothermal actuators

    KAUST Repository

    Rawashdeh, E.; Karam, A.; Foulds, Ian G.

    2012-01-01

    This paper compares the design and performance of kink actuators, a modified version of the bent-beam thermal actuator, to the standard chevron-shaped designs. A variety of kink and chevron actuator designs were fabricated from polysilicon. While the actuators were electrically probed, these designs were tested using a probe station connected to a National Instruments (NI) controller that uses LabVIEW to extract the displacement results via image processing. The displacement results were then used to validate the thermal-electric-structural simulations produced by COMSOL. These results, in turn, were used to extract the stiffness for both actuator types. The data extracted show that chevron actuators can have larger stiffness values with increasing offsets, but at the cost of lower amplification factors. In contrast, kink actuators showed a constant stiffness value equivalent to the chevron actuator with the highest amplification factor. The kink actuator also had larger amplification factors than chevrons at all designs tested. Therefore, kink actuators are capable of longer throws at lower power levels than the standard chevron designs.

  13. Characterization of kink actuators as compared to traditional chevron shaped Bent-Beam electrothermal actuators

    KAUST Repository

    Rawashdeh, E.

    2012-07-06

    This paper compares the design and performance of kink actuators, a modified version of the bent-beam thermal actuator, to the standard chevron-shaped designs. A variety of kink and chevron actuator designs were fabricated from polysilicon. While the actuators were electrically probed, these designs were tested using a probe station connected to a National Instruments (NI) controller that uses LabVIEW to extract the displacement results via image processing. The displacement results were then used to validate the thermal-electric-structural simulations produced by COMSOL. These results, in turn, were used to extract the stiffness for both actuator types. The data extracted show that chevron actuators can have larger stiffness values with increasing offsets, but at the cost of lower amplification factors. In contrast, kink actuators showed a constant stiffness value equivalent to the chevron actuator with the highest amplification factor. The kink actuator also had larger amplification factors than chevrons at all designs tested. Therefore, kink actuators are capable of longer throws at lower power levels than the standard chevron designs.

  14. Thrust Measurement of Dielectric Barrier Discharge (DBD) Plasma Actuators: New Anti-Thrust Hypothesis, Frequency Sweeps Methodology, Humidity and Enclosure Effects

    Science.gov (United States)

    Ashpis, David E.; Laun, Matthew C.

    2014-01-01

    We discuss thrust measurements of Dielectric Barrier Discharge (DBD) plasma actuators devices used for aerodynamic active flow control. After a review of our experience with conventional thrust measurement and significant non-repeatability of the results, we devised a suspended actuator test setup, and now present a methodology of thrust measurements with decreased uncertainty. The methodology consists of frequency scans at constant voltages. The procedure consists of increasing the frequency in a step-wise fashion from several Hz to the maximum frequency of several kHz, followed by frequency decrease back down to the start frequency of several Hz. This sequence is performed first at the highest voltage of interest, then repeated at lower voltages. The data in the descending frequency direction is more consistent and selected for reporting. Sample results show strong dependence of thrust on humidity which also affects the consistency and fluctuations of the measurements. We also observed negative values of thrust, or "anti-thrust", at low frequencies between 4 Hz and up to 64 Hz. The anti-thrust is proportional to the mean-squared voltage and is frequency independent. Departures from the parabolic anti-thrust curve are correlated with appearance of visible plasma discharges. We propose the anti-thrust hypothesis. It states that the measured thrust is a sum of plasma thrust and anti-thrust, and assumes that the anti-thrust exists at all frequencies and voltages. The anti-thrust depends on actuator geometry and materials and on the test installation. It enables the separation of the plasma thrust from the measured total thrust. This approach enables more meaningful comparisons between actuators at different installations and laboratories. The dependence on test installation was validated by surrounding the actuator with a grounded large-diameter metal sleeve. Strong dependence on humidity is also shown; the thrust significantly increased with decreasing humidity, e

  15. Gastroesophageal Reflux Management with the LINX® System for Gastroesophageal Reflux Disease Following Laparoscopic Sleeve Gastrectomy.

    Science.gov (United States)

    Desart, Kenneth; Rossidis, Georgios; Michel, Michael; Lux, Tamara; Ben-David, Kfir

    2015-10-01

    Laparoscopic sleeve gastrectomy (LSG) has gained significant popularity in the USA, and consequently resulted in patients experiencing new-onset gastroesophageal reflux disease (GERD) following this bariatric procedure. Patients with GERD refractory to medical therapy present a more challenging situation limiting the surgical options to further treat the de novo GERD symptoms since the gastric fundus to perform a fundoplication is no longer an option. The aim of this study is to determine if the LINX® magnetic sphincter augmentation system is a safe and effective option for patients with new gastroesophageal reflux disease following laparoscopic sleeve gastrectomy. This study was conducted at the University Medical Center. This is a retrospective review of seven consecutive patients who had a laparoscopic LINX® magnetic sphincter device placement for patients with refractory gastroesophageal reflux disease after laparoscopic sleeve gastrectomy between July 2014 and April 2015. All patients were noted to have self-reported greatly improved gastroesophageal reflux symptoms 2-4 weeks after their procedure. They were all noted to have statistically significant improved severity and frequency of their reflux, regurgitation, epigastric pain, sensation of fullness, dysphagia, and cough symptoms in their postoperative GERD symptoms compared with their preoperative evaluation. This is the first reported pilot case series, illustrating that the LINX® device is a safe and effective option in patients with de novo refractory gastroesophageal reflux disease after a laparoscopic sleeve gastrectomy despite appropriate weight loss.

  16. Mitral Valve Disease

    Science.gov (United States)

    ... for mitral valve replacement—mechanical valves (metal) or biological valves (tissue). The principal advantage of mechanical valves ... small risk of stroke due to blood clotting. Biological valves usually are made from animal tissue. Biological ...

  17. Changes in the makeup of bariatric surgery: a national increase in use of laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Nguyen, Ninh T; Nguyen, Brian; Gebhart, Alana; Hohmann, Samuel

    2013-02-01

    Laparoscopic sleeve gastrectomy is gaining popularity in the US; however, there has been no study examining the use of sleeve gastrectomy at a national level and its impact on the use of other bariatric operations. The aim of this study was to examine contemporary changes in use and outcomes of bariatric surgery performed at academic medical centers. Using ICD-9 diagnosis and procedure codes, clinical data obtained from the University HealthSystem Consortium database for all bariatric procedures performed for the treatment of morbid obesity between October 1, 2008 and September 30, 2012 were reviewed. Quartile trends in use for the 3 most commonly performed bariatric operations were examined, and a comparison of perioperative outcomes between procedures was performed within a subset of patients with minor severity of illness. A total of 60,738 bariatric procedures were examined. In 2008, the makeup of bariatric surgery consisted primarily of gastric bypass (66.8% laparoscopic, 8.6% open), followed by laparoscopic gastric banding (23.8%). In 2012, there was a precipitous increase in use of laparoscopic sleeve gastrectomy (36.3 %), with a concurrent reduction in the use of laparoscopic (56.4%) and open (3.2%) gastric bypass, and a major reduction in laparoscopic gastric banding (4.1%). The length of hospital stay, in-hospital morbidity and mortality, and costs for laparoscopic sleeve gastrectomy were found to be between those of laparoscopic gastric banding and laparoscopic gastric bypass. Within the context of academic medical centers, there has been a recent change in the makeup of bariatric surgery. There has been an increase in the use of laparoscopic sleeve gastrectomy, which has had an impact primarily on reducing the use of laparoscopic adjustable gastric banding. Copyright © 2013 American College of Surgeons. Published by Elsevier Inc. All rights reserved.

  18. Turbulent Motion of Liquids in Hydraulic Resistances with a Linear Cylindrical Slide-Valve

    Directory of Open Access Journals (Sweden)

    C. Velescu

    2015-01-01

    Full Text Available We analyze the motion of viscous and incompressible liquids in the annular space of controllable hydraulic resistances with a cylindrical linear slide-valve. This theoretical study focuses on the turbulent and steady-state motion regimes. The hydraulic resistances mentioned above are the most frequent type of hydraulic resistances used in hydraulic actuators and automation systems. To study the liquids’ motion in the controllable hydraulic resistances with a linear cylindrical slide-valve, the report proposes an original analytic method. This study can similarly be applied to any other type of hydraulic resistance. Another purpose of this study is to determine certain mathematical relationships useful to approach the theoretical functionality of hydraulic resistances with magnetic controllable fluids as incompressible fluids in the presence of a controllable magnetic field. In this report, we established general analytic equations to calculate (i velocity and pressure distributions, (ii average velocity, (iii volume flow rate of the liquid, (iv pressures difference, and (v radial clearance.

  19. Valve thrombosis following transcatheter aortic valve implantation: a systematic review.

    Science.gov (United States)

    Córdoba-Soriano, Juan G; Puri, Rishi; Amat-Santos, Ignacio; Ribeiro, Henrique B; Abdul-Jawad Altisent, Omar; del Trigo, María; Paradis, Jean-Michel; Dumont, Eric; Urena, Marina; Rodés-Cabau, Josep

    2015-03-01

    Despite the rapid global uptake of transcatheter aortic valve implantation, valve trombosis has yet to be systematically evaluated in this field. The aim of this study was to determine the clinical characteristics, diagnostic criteria, and treatment outcomes of patients diagnosed with valve thrombosis following transcatheter aortic valve implantation through a systematic review of published data. Literature published between 2002 and 2012 on valve thrombosis as a complication of transcatheter aortic valve implantation was identified through a systematic electronic search. A total of 11 publications were identified, describing 16 patients (mean age, 80 [5] years, 65% men). All but 1 patient (94%) received a balloon-expandable valve. All patients received dual antiplatelet therapy immediately following the procedure and continued to take either mono- or dual antiplatelet therapy at the time of valve thrombosis diagnosis. Valve thrombosis was diagnosed at a median of 6 months post-procedure, with progressive dyspnea being the most common symptom. A significant increase in transvalvular gradient (from 10 [4] to 40 [12] mmHg) was the most common echocardiographic feature, in addition to leaflet thickening. Thrombus was not directly visualized with echocardiography. Three patients underwent valve explantation, and the remaining received warfarin, which effectively restored the mean transvalvular gradient to baseline within 2 months. Systemic embolism was not a feature of valve thrombosis post-transcatheter aortic valve implantation. Although a rare, yet likely under-reported complication of post-transcatheter aortic valve implantation, progressive dyspnea coupled with an increasing transvalvular gradient on echocardiography within the months following the intervention likely signifies valve thrombosis. While direct thrombus visualization appears difficult, prompt initiation of oral anticoagulation therapy effectively restores baseline valve function. Copyright © 2014

  20. Rotor losses in laminated magnets and an anisotropic carbon fiber sleeve

    NARCIS (Netherlands)

    Van der Geest, M.; Wolmarans, J.J.; Polinder, H.; Ferreira, J.A.; Zeilstra, D.

    2012-01-01

    High speed fault tolerant permanent magnet machines have strong asynchronous airgap harmonics, making them susceptible to rotor eddy-current losses. These losses can be reduced by using novel high resistivity materials like plastic bonded magnets and carbon fiber reinforced retaining sleeves. This

  1. Gastritis in patients undergoing sleeve gastrectomy

    Science.gov (United States)

    Rath-Wolfson, Lea; Varona, Roy; Bubis, Golan; Tatarov, Alexander; Koren, Rumelia; Ram, Edward

    2017-01-01

    Abstract Laparoscopic sleeve gastrectomy (LSG) is a therapeutic option in severely obese patients. The aim of this study was to evaluate the presence of Helicobacter pylori (HP) gastritis and non-Helicobacter gastritis in the gastrectomy specimens, and its association to other variables. One hundred six sleeve gastrectomy specimens were examined histopathologically for the presence of gastritis and its relation to other factors like ethnicity, glycemic control, and postoperative complications. Twelve patients had HP gastritis, 39 had non-HP gastritis, and 55 had normal mucosa. There was a statistical difference between the Arab and Jewish Israeli patients in our study. Twenty-eight of the Arab patients had HP gastritis and 48% had non-HP gastritis. In the Jewish population 6% had HP gastritis and 34% had non-HP gastritis. The preoperative glycemic control was worse in the gastritis group with a mean HbA1c of 8.344% while in the normal mucosa group the mean HbA1c was 6.55. After operation the glycemic control reverted to normal in most the diabetic patients. There were few postoperative complications however, they were not related to HP. There is a high incidence of gastritis in obese patients. The incidence of gastritis in the Arab population in our study was higher than that in the Jewish population. The glycemic control before surgery was worse in patients with gastritis than in the normal mucosa group. HP bares no risk for postoperative complications after LSG and does not affect weight loss. However a larger cohort of patients must be studied to arrive at conclusive results. PMID:28422853

  2. A novel magnetorheological actuator for micro-motion control: identification of actuating characteristics

    International Nuclear Information System (INIS)

    Kaluvan, Suresh; Kim, Soomin; Choi, Seung-Bok; Thirumavalavan, Vinopraba

    2015-01-01

    A novel actuator using magnetorheological (MR) fluid sandwiched between two electrode type coils is proposed in this research work. The key enabling concept of the proposed actuator is to enhance the force due to the magnetic field produced by the electrode coil using the magnetorheological fluid. The direction and amount of current input to the top and bottom electrode coils decide the characteristics such as contraction, extension and the force generated by the actuator, respectively. To obtain the required displacement and actuation force, the viscosity of the MR fluid sandwiched between the two electrode coils is precisely varied by the input current. In this work, the MR fluid is operated in one of the most powerful modes, called squeeze mode, and hence the designed magnetorheological actuator is more powerful and precise. The experimental results shown in this paper show that it has a great advantage in micron-level displacement and vibration control applications. The main contribution of this innovative magnetorheological actuator design is that it can also behave like a damper. This technology will lead to a new dimension in the design of self-actuation and damping devices. In addition, the proposed magnetorheological actuator has additional advantages such as cost effectiveness and easy implementation. (paper)

  3. Tight valve

    International Nuclear Information System (INIS)

    Guedj, F.

    1987-01-01

    This sealed valve is made with a valve seat, an axial valve with a rod fixed to its upper end, a thick bell surrounding the rod and welded by a thin join on the valve casing, a threated ring screwed onto the upper end of the rod and a magnet or electromagnet rotating the ring outside the bell [fr

  4. Aortic valve bypass

    DEFF Research Database (Denmark)

    Lund, Jens T; Jensen, Maiken Brit; Arendrup, Henrik

    2013-01-01

    In aortic valve bypass (AVB) a valve-containing conduit is connecting the apex of the left ventricle to the descending aorta. Candidates are patients with symptomatic aortic valve stenosis rejected for conventional aortic valve replacement (AVR) or transcatheter aortic valve implantation (TAVI). ...

  5. Self-Latching Piezocomposite Actuator

    Science.gov (United States)

    Wilkie, William K. (Inventor); Bryant, Robert G. (Inventor); Lynch, Christopher S. (Inventor)

    2017-01-01

    A self-latching piezocomposite actuator includes a plurality of shape memory ceramic fibers. The actuator can be latched by applying an electrical field to the shape memory ceramic fibers. The actuator remains in a latched state/shape after the electrical field is no longer present. A reverse polarity electric field may be applied to reset the actuator to its unlatched state/shape. Applied electric fields may be utilized to provide a plurality of latch states between the latched and unlatched states of the actuator. The self-latching piezocomposite actuator can be used for active/adaptive airfoils having variable camber, trim tabs, active/deformable engine inlets, adaptive or adjustable vortex generators, active optical components such as mirrors that change shapes, and other morphing structures.

  6. Finite element analysis of a novel pin-sleeve system for external fixation of distal limb fractures in horses.

    Science.gov (United States)

    Brianza, Stefano; Brighenti, Vittoria; Lansdowne, Jennifer L; Schwieger, Karsten; Bouré, Ludovic

    2011-11-01

    The transfixation pin cast (TPC) is an external skeletal fixation technique used to treat horses with distal limb fractures, but its use is often associated with pin-loosening and an increased risk of treatment failure. To address implant loosening, the pin sleeve cast system (PSC) was recently designed and consists of a pin-sleeve unit inserted into the bone. Each pin runs through a sleeve placed in the bone, making contact at two fixed points only within the sleeve. Each pin is attached to a ring embedded in a resin cast. In this report, the mechanical performance of a traditional TPC pin arrangement was compared with that of the PSC using validated finite element models of bone substitutes previously tested in vitro. The PSC resulted in a marked reduction in peak strain magnitude around the pins and a more even distribution of strain across the bone cortex. The two systems resulted in comparable proximal fragment displacement and had a similar stress concentration around bone defects during implant removal. The findings suggest that the PSC load transfer mechanism is effective even in geometrically complex structures like equine bones. Copyright © 2010 Elsevier Ltd. All rights reserved.

  7. The design, effectiveness and acceptability of the arm sleeve for the prevention of body fluid contamination during obstetric procedures.

    Science.gov (United States)

    Kabukoba, J J; Pearce, J M

    1993-08-01

    1. To design a device that would reduce contamination of staff during obstetric procedures. 2. To undertake clinical trials to assess the effectiveness and acceptability of such a device. A prospective study. The arm sleeve is made of a nonwoven material laminated on polyethylene film making it waterproof. It has an elastomeric cuff with adhesive that ensures a watertight seal between it and the glove. Delivery suite in a teaching hospital. Doctors and midwives were requested to wear the sleeve on top of the standard gown and gloves. Each user was assessed for blood contamination at the end of the procedure and a questionnaire detailing the extent of contamination and the views of the user was completed. Eighty questionnaires were completed. The contamination of arms and hands was 3.8% and 5%, respectively. Eighty-nine percent thought the sleeve had served its purpose and 76% said they would use it regularly. The sleeve is an effective protective device which complements the glove and gown. We recommend that it should be used during all obstetric procedures.

  8. Effect of vertical sleeve gastrectomy in melanocortin receptor 4-deficient rats

    NARCIS (Netherlands)

    Mul, J.D.; Begg, D.P.; Alsters, S.I.; van Haaften, G.; Duran, K.J.; D'Alessio, D.A.; le Roux, C.W.; Woods, S.C.; Sandoval, D.A.; Blakemore, A.I.; Cuppen, E.; van Haelst, M.M.; Seeley, R.J.

    2012-01-01

    Bariatric surgery is currently the most effective treatment for obesity. Vertical sleeve gastrectomy (VSG), a commonly applied bariatric procedure, involves surgically incising most of the volume of the stomach. In humans, partial loss of melanocortin receptor-4 (MC4R) activity is the most common

  9. Transcatheter aortic valve implantation in failed bioprosthetic surgical valves

    DEFF Research Database (Denmark)

    Dvir, Danny; Webb, John G; Bleiziffer, Sabine

    2014-01-01

    for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING......, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation...... and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83...

  10. Sleeve resection for delayed presentation of traumatic bronchial transection.

    LENUS (Irish Health Repository)

    Mohamed, H Y

    2010-02-01

    Tracheobronchial disruption is uncommon in blunt chest trauma. Many of these patients die before reaching the hospital. In the majority of survivors diagnosis is occasionally delayed resulting in complications like airway stenosis and lung collapse. Thus it is important to have radiological follow up after severe thoracic trauma. Sleeve resection can be an excellent option to conserve lung tissue in delayed presentation of bronchial transection.

  11. Actuator device utilizing a conductive polymer gel

    Science.gov (United States)

    Chinn, Douglas A.; Irvin, David J.

    2004-02-03

    A valve actuator based on a conductive polymer gel is disclosed. A nonconductive housing is provided having two separate chambers separated by a porous frit. The conductive polymer is held in one chamber and an electrolyte solution, used as a source of charged ions, is held in the second chamber. The ends of the housing a sealed with a flexible elastomer. The polymer gel is further provide with electrodes with which to apply an electrical potential across the gel in order to initiate an oxidation reaction which in turn drives anions across the porous frit and into the polymer gel, swelling the volume of the gel and simultaneously contracting the volume of the electrolyte solution. Because the two end chambers are sealed the flexible elastomer expands or contracts with the chamber volume change. By manipulating the potential across the gel the motion of the elastomer can be controlled to act as a "gate" to open or close a fluid channel and thereby control flow through that channel.

  12. Worm gearing for valve automation; Schneckengetriebe fuer die Armaturenautomatisierung

    Energy Technology Data Exchange (ETDEWEB)

    Herbstritt, Michael [AUMA Riester GmbH und Co. KG, Muellheim (Germany)

    2010-11-15

    Part-turn gearboxes are indispensable for exertion of the torques necessary for large part-turn valves. Torque demand has increased in the past decade, as a result, for example, of the use of pipelines of ever greater diameters in large conurbations, and of the operation of such pipelines at ever higher pressures. The design principle of a worm gear is useful in this context. Worm gearing systems with initial torques of up to 675,000 Nm are now available. The design of gearing systems capable of handling forces of this magnitude necessitates great know-how and experience. The very maximum of reliability is a basic requirement for actuator systems for applications involving such dimensions, since a failure may have catastrophic consequences. (orig.)

  13. Integration of continuous-flow sampling with microchip electrophoresis using poly(dimethylsiloxane)-based valves in a reversibly sealed device.

    Science.gov (United States)

    Li, Michelle W; Martin, R Scott

    2007-07-01

    Here we describe a reversibly sealed microchip device that incorporates poly(dimethylsiloxane) (PDMS)-based valves for the rapid injection of analytes from a continuously flowing stream into a channel network for analysis with microchip electrophoresis. The microchip was reversibly sealed to a PDMS-coated glass substrate and microbore tubing was used for the introduction of gas and fluids to the microchip device. Two pneumatic valves were incorporated into the design and actuated on the order of hundreds of milliseconds, allowing analyte from a continuously flowing sampling stream to be injected into an electrophoresis separation channel. The device was characterized in terms of the valve actuation time and pushback voltage. It was also found that the addition of sodium dodecyl sulfate (SDS) to the buffer system greatly increased the reproducibility of the injection scheme and enabled the analysis of amino acids derivatized with naphthalene-2,3-dicarboxaldehyde/cyanide. Results from continuous injections of a 0.39 nL fluorescein plug into the optimized system showed that the injection process was reproducible (RSD of 0.7%, n = 10). Studies also showed that the device was capable of monitoring off-chip changes in concentration with a device lag time of 90 s. Finally, the ability of the device to rapidly monitor on-chip concentration changes was demonstrated by continually sampling from an analyte plug that was derivatized upstream from the electrophoresis/continuous flow interface. A reversibly sealed device of this type will be useful for the continuous monitoring and analysis of processes that occur either off-chip (such as microdialysis sampling) or on-chip from other integrated functions.

  14. Architecture and permeability of post-cytokinesis plasmodesmata lacking cytoplasmic sleeves.

    Science.gov (United States)

    Nicolas, William J; Grison, Magali S; Trépout, Sylvain; Gaston, Amélia; Fouché, Mathieu; Cordelières, Fabrice P; Oparka, Karl; Tilsner, Jens; Brocard, Lysiane; Bayer, Emmanuelle M

    2017-06-12

    Plasmodesmata are remarkable cellular machines responsible for the controlled exchange of proteins, small RNAs and signalling molecules between cells. They are lined by the plasma membrane (PM), contain a strand of tubular endoplasmic reticulum (ER), and the space between these two membranes is thought to control plasmodesmata permeability. Here, we have reconstructed plasmodesmata three-dimensional (3D) ultrastructure with an unprecedented level of 3D information using electron tomography. We show that within plasmodesmata, ER-PM contact sites undergo substantial remodelling events during cell differentiation. Instead of being open pores, post-cytokinesis plasmodesmata present such intimate ER-PM contact along the entire length of the pores that no intermembrane gap is visible. Later on, during cell expansion, the plasmodesmata pore widens and the two membranes separate, leaving a cytosolic sleeve spanned by tethers whose presence correlates with the appearance of the intermembrane gap. Surprisingly, the post-cytokinesis plasmodesmata allow diffusion of macromolecules despite the apparent lack of an open cytoplasmic sleeve, forcing the reassessment of the mechanisms that control plant cell-cell communication.

  15. Statistical analysis on failure-to-open/close probability of motor-operated valve in sodium system

    International Nuclear Information System (INIS)

    Kurisaka, Kenichi

    1998-08-01

    The objective of this work is to develop basic data for examination on efficiency of preventive maintenance and actuation test from the standpoint of failure probability. This work consists of a statistical trend analysis of valve failure probability in a failure-to-open/close mode on time since installation and time since last open/close action, based on the field data of operating- and failure-experience. In this work, the terms both dependent and independent on time were considered in the failure probability. The linear aging model was modified and applied to the first term. In this model there are two terms with both failure rates in proportion to time since installation and to time since last open/close-demand. Because of sufficient statistical population, motor-operated valves (MOV's) in sodium system were selected to be analyzed from the CORDS database which contains operating data and failure data of components in the fast reactors and sodium test facilities. According to these data, the functional parameters were statistically estimated to quantify the valve failure probability in a failure-to-open/close mode, with consideration of uncertainty. (J.P.N.)

  16. Fast electrochemical actuator

    International Nuclear Information System (INIS)

    Uvarov, I V; Postnikov, A V; Svetovoy, V B

    2016-01-01

    Lack of fast and strong microactuators is a well-recognized problem in MEMS community. Electrochemical actuators can develop high pressure but they are notoriously slow. Water electrolysis produced by short voltage pulses of alternating polarity can overcome the problem of slow gas termination. Here we demonstrate an actuation regime, for which the gas pressure is relaxed just for 10 μs or so. The actuator consists of a microchamber filled with the electrolyte and covered with a flexible membrane. The membrane bends outward when the pressure in the chamber increases. Fast termination of gas and high pressure developed in the chamber are related to a high density of nanobubbles in the chamber. The physical processes happening in the chamber are discussed so as problems that have to be resolved for practical applications of this actuation regime. The actuator can be used as a driving engine for microfluidics. (paper)

  17. Electro-actuation characteristics of Cl2 and SF6 plasma-treated IPMC actuators

    International Nuclear Information System (INIS)

    Saher, Saim; Kim, Woojin; Moon, Sungwon; Jin Kim, H; Kim, Yong Hyup

    2010-01-01

    This paper describes plasma treatments that improve the actuation properties by modifying the surface morphology of ionic polymer metal composites (IPMC). The proposed Cl 2 and SF 6 plasmas change the surface appearance of the electroactive polymer, and scanning electron microscopy (SEM) of the plasma-treated surfaces reveals the development of round and cone-shaped microstructures. After electroless chemical metal plating, these microstructures significantly alter the characteristics of the IPMC electrode. In plasma-treated IPMCs, the densely packed platinum nanoparticles have produced a relatively thick electrode layer. This configuration has led to the improvement in the electrical properties of the IPMC: surface resistance is noticeably decreased, whereas electrical capacitance is increased. These changes in the electrical properties have considerably enhanced the actuation parameters: displacement, force and operational life are increased by more than three times relative to the conventional IPMC. Our experimental data suggest a relationship between the IPMC actuator's electrical properties and actuation parameters: actuators with lower surface resistance generate large deflection and actuators with higher capacitance generate large actuation force. The actuation tests including coin lifting suggests the potential of the modified IPMC for artificial muscle applications

  18. Multidetector computed tomography sizing of bioprosthetic valves: guidelines for measurement and implications for valve-in-valve therapies

    International Nuclear Information System (INIS)

    Rajani, R.; Attia, R.; Condemi, F.; Webb, J.; Woodburn, P.; Hodson, D.; Nair, A.; Preston, R.; Razavi, R.; Bapat, V.N.

    2016-01-01

    Aim: To describe a technique for bioprosthetic multidetector computed tomography (MDCT) sizing and to compare MDCT-derived values against manufacturer-provided sizing. Materials and methods: Fourteen bioprosthetic stented valves commonly used in the aortic valve position were evaluated using a Philips 256 MDCT system. All valves were scanned using a dedicated cardiac CT protocol with a four-channel electrocardiography (ECG) simulator. Measurements were made of major and minor axes and the area and perimeter of the internal stent using varying reconstruction kernels and window settings. Measurements derived from MDCT (MDCT ID) were compared against the stent internal diameter (Stent ID) as provided by the valve manufacturer and the True ID (Stent ID + insertion of leaflets). All data were collected and analysed using SPSS for Mac (version 21). Results: The mean difference between the MDCT ID and Stent ID was 0.6±1.9 mm (r=0.649, p=0.012) and between MDCT ID and True ID 2.1±2 mm (r=0.71, p=0.005). There was no difference in the major (p=0.90), minor (p=0.87), area (p=0.92), or perimeter (p=0.92) measurements when sharp, standard, and detailed stent kernels were used. Similarly, the measurements remained consistent across differing windowing levels. Conclusion: Bioprosthetic stented valves may be reliably sized using MDCT in patients requiring valve-in-valve (VIV) interventions where the valve type and size are unknown. In these cases, clinicians should be aware that MDCT has a tendency to overestimate the True ID size. - Highlights: • Cardiac CT is likely to be ideally suited for bioprosthetic aortic valve sizing for valve in valve procedures. • We compared MDCT sizing for 14 varying bioprosthetic aortic valves across varying window settings and reconstruction kernels. • We provide “normal” MDCT sizing for varying valves and show their relationship to surgical sizing. • Bioprosthetic valves may be reliably sized by MDCT but require adjustment owing to

  19. Swing check valve

    International Nuclear Information System (INIS)

    Eminger, H.E.

    1977-01-01

    A swing check valve which includes a valve body having an inlet and outlet is described. A recess in the valve body designed to hold a seal ring and a check valve disc swingable between open and closed positions. The disc is supported by a high strength wire secured at one end in a support spacer pinned through bearing blocks fixed to the valve body and at its other end in a groove formed on the outer peripheral surface of the disc. The parts are designed and chosen such to provide a lightweight valve disc which is held open by minimum velocity of fluid flowing through the valve which thus reduces oscillations and accompanying wear of bearings supporting the valve operating parts. (Auth.)

  20. Digital Actuator Technology

    Energy Technology Data Exchange (ETDEWEB)

    Ken Thomas; Ted Quinn; Jerry Mauck; Richard Bockhorst

    2014-09-01

    There are significant developments underway in new types of actuators for power plant active components. Many of these make use of digital technology to provide a wide array of benefits in performance of the actuators and in reduced burden to maintain them. These new product offerings have gained considerable acceptance in use in process plants. In addition, they have been used in conventional power generation very successfully. This technology has been proven to deliver the benefits promised and substantiate the claims of improved performance. The nuclear industry has been reluctant to incorporate digital actuator technology into nuclear plant designs due to concerns due to a number of concerns. These could be summarized as cost, regulatory uncertainty, and a certain comfort factor with legacy analog technology. The replacement opportunity for these types of components represents a decision point for whether to invest in more modern technology that would provide superior operational and maintenance benefits. Yet, the application of digital technology has been problematic for the nuclear industry, due to qualification and regulatory issues. With some notable exceptions, the result has been a continuing reluctance to undertake the risks and uncertainties of implementing digital actuator technology when replacement opportunities present themselves. Rather, utilities would typically prefer to accept the performance limitations of the legacy analog actuator technologies to avoid impacts to project costs and schedules. The purpose of this report is to demonstrate that the benefits of digital actuator technology can be significant in terms of plant performance and that it is worthwhile to address the barriers currently holding back the widespread development and use of this technology. It addresses two important objectives in pursuit of the beneficial use of digital actuator technology for nuclear power plants: 1. To demonstrate the benefits of digital actuator

  1. Effect of Laparoscopic Sleeve Gastrectomy vs Laparoscopic Roux-en-Y Gastric Bypass on Weight Loss in Patients With Morbid Obesity: The SM-BOSS Randomized Clinical Trial.

    Science.gov (United States)

    Peterli, Ralph; Wölnerhanssen, Bettina Karin; Peters, Thomas; Vetter, Diana; Kröll, Dino; Borbély, Yves; Schultes, Bernd; Beglinger, Christoph; Drewe, Jürgen; Schiesser, Marc; Nett, Philipp; Bueter, Marco

    2018-01-16

    Sleeve gastrectomy is increasingly used in the treatment of morbid obesity, but its long-term outcome vs the standard Roux-en-Y gastric bypass procedure is unknown. To determine whether there are differences between sleeve gastrectomy and Roux-en-Y gastric bypass in terms of weight loss, changes in comorbidities, increase in quality of life, and adverse events. The Swiss Multicenter Bypass or Sleeve Study (SM-BOSS), a 2-group randomized trial, was conducted from January 2007 until November 2011 (last follow-up in March 2017). Of 3971 morbidly obese patients evaluated for bariatric surgery at 4 Swiss bariatric centers, 217 patients were enrolled and randomly assigned to sleeve gastrectomy or Roux-en-Y gastric bypass with a 5-year follow-up period. Patients were randomly assigned to undergo laparoscopic sleeve gastrectomy (n = 107) or laparoscopic Roux-en-Y gastric bypass (n = 110). The primary end point was weight loss, expressed as percentage excess body mass index (BMI) loss. Exploratory end points were changes in comorbidities and adverse events. Among the 217 patients (mean age, 45.5 years; 72% women; mean BMI, 43.9) 205 (94.5%) completed the trial. Excess BMI loss was not significantly different at 5 years: for sleeve gastrectomy, 61.1%, vs Roux-en-Y gastric bypass, 68.3% (absolute difference, -7.18%; 95% CI, -14.30% to -0.06%; P = .22 after adjustment for multiple comparisons). Gastric reflux remission was observed more frequently after Roux-en-Y gastric bypass (60.4%) than after sleeve gastrectomy (25.0%). Gastric reflux worsened (more symptoms or increase in therapy) more often after sleeve gastrectomy (31.8%) than after Roux-en-Y gastric bypass (6.3%). The number of patients with reoperations or interventions was 16/101 (15.8%) after sleeve gastrectomy and 23/104 (22.1%) after Roux-en-Y gastric bypass. Among patients with morbid obesity, there was no significant difference in excess BMI loss between laparoscopic sleeve gastrectomy and laparoscopic Roux

  2. Steam generator thermal sleeve reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Caton, E.; Askari, A.; Volder, P. [Babcock and Wilcox Canada Ltd., Cambridge, Ontario (Canada)]. E-mail: eecaton@babcock.com

    2003-07-01

    'Full text:' Successful implementation of a physically difficult repair program requires collaboration of the design and construction functions of an organization to ensure that goals are shared and rework or on-the-fly design changes are not required. Furthermore, in a nuclear facility this collaboration results in the optimal safety condition as dose uptake is minimized with a well planned job. The replacement of the degraded thermal sleeves in the Pickering A Steam Generator feedwater nozzles posed this type of problem. The project may be summarized as follows: i) problem analysis, ii) identification of design parameters and limitations, iii) integration of field engineering and design engineering solutions, iv) installation. Integration of the design engineering and field engineering design parameters ensured that the most effective solution was implemented. (author)

  3. Cylindrical Piezoelectric Fiber Composite Actuators

    Science.gov (United States)

    Allison, Sidney G.; Shams, Qamar A.; Fox, Robert L.

    2008-01-01

    The use of piezoelectric devices has become widespread since Pierre and Jacques Curie discovered the piezoelectric effect in 1880. Examples of current applications of piezoelectric devices include ultrasonic transducers, micro-positioning devices, buzzers, strain sensors, and clocks. The invention of such lightweight, relatively inexpensive piezoceramic-fiber-composite actuators as macro fiber composite (MFC) actuators has made it possible to obtain strains and displacements greater than those that could be generated by prior actuators based on monolithic piezoceramic sheet materials. MFC actuators are flat, flexible actuators designed for bonding to structures to apply or detect strains. Bonding multiple layers of MFC actuators together could increase force capability, but not strain or displacement capability. Cylindrical piezoelectric fiber composite (CPFC) actuators have been invented as alternatives to MFC actuators for applications in which greater forces and/or strains or displacements may be required. In essence, a CPFC actuator is an MFC or other piezoceramic fiber composite actuator fabricated in a cylindrical instead of its conventional flat shape. Cylindrical is used here in the general sense, encompassing shapes that can have circular, elliptical, rectangular or other cross-sectional shapes in the planes perpendicular to their longitudinal axes.

  4. De novo gastric adenocarcinoma 1 year after sleeve gastrectomy in a transplant patient

    Directory of Open Access Journals (Sweden)

    M. Masrur

    2016-01-01

    Conclusions: No direct relation has been established between sleeve gastrectomy and the development of gastric cancer. Robotic procedures allow for complex multiorgan resections, while preserving the benefits of minimally invasive surgery.

  5. Laparoscopic Gastric Sleeve and Micronutrients Supplementation: Our Experience

    Directory of Open Access Journals (Sweden)

    D. Capoccia

    2012-01-01

    Full Text Available Background. Laparoscopic gastric sleeve (LGS has been recently introduced as a stand-alone, restrictive bariatric surgery. Theoretically, LGS attenuates micronutrients deficiencies and associated complications that were typically observed following malabsorptive procedures. The aim of this study was to assess some micronutrients and mineral deficiencies in patients undergoing LGS. Methods. In the period between July 2008 and April 2010, 138 obese patients (110 females and 28 males with mean BMI 44.4 kg/m2 ± 6.5, mean age 43.9±10.9 years were enrolled and underwent LGS. Patients were followed up with routine laboratory tests and anthropometric measurements and assessed for nutritional status, as regards vitamin B12, folic acid, iron, hemoglobin, calcium, and vitamin D, every three months throughout 12 months. Results. 12 months after sleeve, patients did not show iron deficiency and/or anemia; plasma calcium levels were in the normal range without supplementation from the sixth month after the operation. Vitamin B12 and folic acid were adequately supplemented for all the follow-up period. Vitamin D was in suboptimal levels, despite daily multivitamin supplementation. Conclusion. In this study, we showed that LGS is an effective surgery for the management of morbid obesity. An adequate supplementation is important to avoid micronutrients deficiencies and greater weight loss does not require higher dosage of multivitamins.

  6. Actuators for smart applications

    NARCIS (Netherlands)

    Paternoster, Alexandre; de Boer, Andries; Loendersloot, Richard; Akkerman, Remko; D. Brei,; M. Frecker,

    2010-01-01

    Actuator manufacturers are developing promising technologies which meet high requirements in performance, weight and power consumption. Conventionally, actuators are characterized by their displacement and load performance. This hides the dynamic aspects of those actuation solutions. Work per weight

  7. Dynamic actuation of a novel laser-processed NiTi linear actuator

    International Nuclear Information System (INIS)

    Pequegnat, A; Daly, M; Wang, J; Zhou, Y; Khan, M I

    2012-01-01

    A novel laser processing technique, capable of locally modifying the shape memory effect, was applied to enhance the functionality of a NiTi linear actuator. By altering local transformation temperatures, an additional memory was imparted into a monolithic NiTi wire to enable dynamic actuation via controlled resistive heating. Characterizations of the actuator load, displacement and cyclic properties were conducted using a custom-built spring-biased test set-up. Monotonic tensile testing was also implemented to characterize the deformation behaviour of the martensite phase. Observed differences in the deformation behaviour of laser-processed material were found to affect the magnitude of the active strain. Furthermore, residual strain during cyclic actuation testing was found to stabilize after 150 cycles while the recoverable strain remained constant. This laser-processed actuator will allow for the realization of new applications and improved control methods for shape memory alloys. (paper)

  8. Resident education in robotic-assisted vertical sleeve gastrectomy: outcomes and cost-analysis of 411 consecutive cases.

    Science.gov (United States)

    Ecker, Brett L; Maduka, Richard; Ramdon, Andre; Dempsey, Daniel T; Dumon, Kristoffel R; Williams, Noel N

    2016-02-01

    Robotic technology is increasingly prevalent in bariatric surgery, yet there are national deficiencies in exposure of surgical residents to robotic techniques. The purpose of this study is to accurately characterize the perioperative outcomes of a resident teaching model using the robotic-assisted sleeve gastrectomy. University Hospital. We identified 411 consecutive patients who underwent robotic sleeve gastrectomy at our institution from a prospectively maintained administrative database. Perioperative morbidity, operative time, and supply cost of the procedure were analyzed. Mean operative time was 96.4±24.9 minutes; mean robot usage time was 63.9 minutes (range 30.0-122.0 min). Ninety-day morbidities included reoperation (0.72%), major bleeding complications (0.48%), staple line leak (0.24%), stricture (0.97%), need for blood transfusion (3.86%), surgical site infection (1.69%), deep vein thrombosis (0.48%), and pulmonary embolism (0.48%). Mortality was nil. The resident cohort achieved operative time plateaus after five consecutive cases. Subset analysis for fiscal year 2014 demonstrated significantly increased supply cost for robotic sleeve gastrectomy compared with its laparoscopic equivalent. Robotic-assisted sleeve gastrectomy can be instituted as a model for resident robotic education with rates of morbidity and operative times equivalent to historical laparoscopic controls. The robot's enhanced ergonomics and its opportunity for resident education must be weighed against its increased supply cost. Copyright © 2016 American Society for Bariatric Surgery. Published by Elsevier Inc. All rights reserved.

  9. Creep-Fatigue Relationsihps in Electroactive Polymer Systems and Predicted Effects in an Actuator Design

    Science.gov (United States)

    Vinogradov, Aleksandra M.; Ihlefeld, Curtis M.; Henslee, Issac

    2009-01-01

    The paper concerns the time-dependent behavior of electroactive polymers (EAP) and their use in advanced intelligent structures for space exploration. Innovative actuator design for low weight and low power valves required in small plants planned for use on the moon for chemical analysis is discussed. It is shown that in-depth understanding of cyclic loading effects observed through accelerated creep rates due to creep-fatigue interaction in polymers is critical in terms of proper functioning of EAP based actuator devices. In the paper, an overview of experimental results concerning the creep properties and cyclic creep response of a thin film piezoelectric polymer polyvinylidene fluoride (PVDF) is presented. The development of a constitutive creep-fatigue interaction model to predict the durability and service life of electroactive polymers is discussed. A novel method is proposed to predict damage accumulation and fatigue life of polymers under oyclic loading conditions in the presence of creep. The study provides a basis for ongoing research initiatives at the NASA Kennedy Space Center in the pursuit of new technologies using EAP as active elements for lunar exploration systems.

  10. Valve Disease

    Science.gov (United States)

    ... blood. There are 4 valves in the heart: tricuspid, pulmonary, mitral, and aortic. Two types of problems can disrupt blood flow through the valves: regurgitation or stenosis. Regurgitation is also called insufficiency or incompetence. Regurgitation happens when a valve doesn’ ...

  11. Fabrication and actuation of electro-active polymer actuator based on PSMI-incorporated PVDF

    Science.gov (United States)

    Lu, Jun; Kim, Sang-Gyun; Lee, Sunwoo; Oh, Il-Kwon

    2008-08-01

    In this study, an ionic networking membrane (INM) of poly(styrene-alt-maleimide) (PSMI)-incorporated poly(vinylidene fluoride) (PVDF) was applied to fabricate electro-active polymer. Based on the same original membrane of PSMI-incorporated PVDF, various samples of INM actuator were prepared for different reduction times with the electroless-plating technique. The as-prepared INM actuators were tested in terms of surface resistance, platinum morphology, resonance frequency, tip displacement, current and blocked force, and their performances were compared to those of the widely used traditional Nafion actuator. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) revealed that much smaller and more uniform platinum particles were formed on the surfaces of the INM actuators as well as within their polymer matrix. Although excellent harmonic responses were observed for the newly developed INM actuators, they were found to be sensitive to the applied reduction times during the fabrication. The mechanical displacement of the INM actuator fabricated after the optimum reduction times was much larger than that of its Nafion counterpart of comparable thickness under the stimulus of constant and alternating current voltage. The PSMI-incorporated PVDF actuator can become a promising smart material to be used in the fields of biomimetic robots, biomedical devices, sensors and actuator, haptic interfaces, energy harvesting and so on.

  12. Fabrication and actuation of electro-active polymer actuator based on PSMI-incorporated PVDF

    International Nuclear Information System (INIS)

    Lu, Jun; Oh, Il-Kwon; Kim, Sang-Gyun; Lee, Sunwoo

    2008-01-01

    In this study, an ionic networking membrane (INM) of poly(styrene-alt-maleimide) (PSMI)-incorporated poly(vinylidene fluoride) (PVDF) was applied to fabricate electro-active polymer. Based on the same original membrane of PSMI-incorporated PVDF, various samples of INM actuator were prepared for different reduction times with the electroless-plating technique. The as-prepared INM actuators were tested in terms of surface resistance, platinum morphology, resonance frequency, tip displacement, current and blocked force, and their performances were compared to those of the widely used traditional Nafion actuator. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) revealed that much smaller and more uniform platinum particles were formed on the surfaces of the INM actuators as well as within their polymer matrix. Although excellent harmonic responses were observed for the newly developed INM actuators, they were found to be sensitive to the applied reduction times during the fabrication. The mechanical displacement of the INM actuator fabricated after the optimum reduction times was much larger than that of its Nafion counterpart of comparable thickness under the stimulus of constant and alternating current voltage. The PSMI-incorporated PVDF actuator can become a promising smart material to be used in the fields of biomimetic robots, biomedical devices, sensors and actuator, haptic interfaces, energy harvesting and so on

  13. Composting municipal biosolids in polyethylene sleeves with forced aeration: Process control, air emissions, sanitary and agronomic aspects.

    Science.gov (United States)

    Avidov, R; Saadi, I; Krassnovsky, A; Hanan, A; Medina, Sh; Raviv, M; Chen, Y; Laor, Y

    2017-09-01

    Composting in polyethylene sleeves with forced aeration may minimize odor emissions, vectors attraction and leachates associated with open windrows. A disadvantage of this technology is the lack of mixing during composting, potentially leading to non-uniform products. In two pilot experiments using biosolids and green waste (1:1; v:v), thermophilic conditions (>45°C) were maintained for two months, with successful control of oxygen levels and sufficient moisture. Emitted odors declined from 1.5-3.8×10 5 to 5.9×10 3 -2.3×10 4 odor units m -3 -air in the first 3weeks of the process, emphasizing the need of odor control primarily during this period. Therefore, composting might be managed in two phases: (i) a closed sleeve for 6-8weeks during which the odor is treated; (ii) an open pile (odor control is not necessary). Reduction of salmonella, E. coli and coliforms was effective initially, meeting the standards of "Class A" biosolids; however, total and fecal coliforms density increased after opening the second sleeve and exceeded the standard of 1000 most probable number (MPN) per g dry matter. Compost maturity was achieved in the open piles following the two sleeves and the final compost was non-phytotoxic and beneficial as a soil additive. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Structure and properties of braided sleeve preforms for chemical vapor infiltration

    Energy Technology Data Exchange (ETDEWEB)

    Starr, T.L.; Fiadzo, O.G.; Hablutzel, N. [Georgia Inst. of Tech., Atlanta, GA (United States). School of Materials Science and Technology

    1998-04-01

    In all composites the properties and structure of the reinforcement strongly influence the performance of the material. For some composites, however, the reinforcement also affects the fabrication process itself exerting an additional, second order influence on performance. This is the case for the chemical vapor infiltration (CVI) process for fabrication of ceramic matrix composites. In this process the matrix forms progressively as a solid deposit, first onto the fiber surfaces, then onto the previous layer of deposit, ultimately growing to fill the inter-fiber porosity. The transport of reactants to the surfaces and the evolved morphology of the matrix depend on the initial reinforcement structure. This structure can vary greatly and is controlled by such factors as fiber size and cross-section, the number of filaments and amount of twist per tow or yarn, and the weave or braid architecture. Often the choice of reinforcement is based on mechanical performance analysis or on the cost and availability of the material or on the temperature stability of the fiber. Given this choice, the composite densification process--CVI--must be optimized to attain a successful material. Ceramic fiber in the form of cylindrical braided sleeve is an attractive choice for fabrication of tube-form ceramic matrix composites. Multiple, concentric layers of sleeve can be placed over a tubular mandrel, compressed and fixed with a binder to form a freestanding tube preform. This fiber architecture is different than that created by layup of plain weave cloth--the material used in most previous CVI development. This report presents the results of the investigation of CVI densification of braided sleeve preforms and the evolution of their structure and transport properties during processing.

  15. Aortic Valve Stenosis

    Science.gov (United States)

    ... most cases, doctors don't know why a heart valve fails to develop properly, so it isn't something you could have prevented. Calcium buildup on the valve. With age, heart valves may accumulate deposits of calcium (aortic valve ...

  16. Effect of Sleeve Plunge Depth on Microstructure and Mechanical Properties of Refill Friction Stir Spot Welding of 2198 Aluminum Alloy

    Science.gov (United States)

    Yue, Yumei; Shi, Yao; Ji, Shude; Wang, Yue; Li, Zhengwei

    2017-10-01

    Refill friction stir spot welding (RFSSW) is a new spot welding technology, by which spot joint without keyhole can be obtained. In this work, RFSSW was used to join 2-mm-thick 2198-T8 aluminum alloy sheets and effects of the sleeve plunge depth on microstructure and lap shear properties of the joints were mainly discussed. Results showed that when using small plunge depths of 2.4 and 2.6 mm, joints showed good formation and no defects were observed. Incomplete refilling defect was observed with increasing plunge depth due to material loss during welding. Size of the grains at sleeve-affected zone (SAZ) is smaller than that at the pin-affected zone, and the size becomes bigger with increasing the plunge depth. More secondary phase particles can be observed at SAZ with increasing the sleeve plunge depth. The lap shear failure load firstly increased and then decreased with increasing the sleeve plunge depth. The maximum failure load of 9819 N was attained with plug fracture mode when using 2.6 mm. Fracture morphologies show ductile fracture mode.

  17. Concurrent Mesh Repair of a Morgagni and Umbilical Hernia during a Laparoscopic Sleeve Gastrectomy in a Morbidly Obese Individual

    Directory of Open Access Journals (Sweden)

    N.R Kosai

    2016-10-01

    Full Text Available Morgagni Hernia is a rare form of diaphragmatic hernia. It is mainly asymptomatic and often identified incidentally during surgery. Tension-free synthetic mesh repair is the preferred treatment modality. However, the use of synthetic mesh concurrently during a clean-contaminated surgery such as sleeve gastrectomy remains controversial due to the remote possibility of mesh infection. A middle-aged female 2 with BMI of 47 Kg/m was admitted electively for laparoscopic sleeve gastrectomy with concurrent umbilical hernia repair. Intra-operatively, a left Morgagni Hernia containing omentum and a segment of transverse colon was noted. She underwent a laparoscopic sleeve gastrectomy and simultaneous laparoscopic tension-free composite mesh repair of both Morgagni and umbilical hernia. Outpatient review three months later revealed excess weight loss of almost 30% with no recurrence of either hernia. In conclusion, the advantages of concurrent hernia repair during bariatric surgery outweigh the risk of mesh infection and should be performed to prevent future risk of visceral herniation and strangulation. Laparoscopic mesh repair of a Morgagni Hernia and umbilical hernia in the setting of an electively planned sleeve gastrectomy is feasible, effective and safe in the hands of a trained laparoscopic surgeon.

  18. pH monitoring of gastro-oesophageal reflux before and after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Thereaux, J; Barsamian, C; Bretault, M; Dusaussoy, H; Lamarque, D; Bouillot, J-L; Czernichow, S; Carette, C

    2016-03-01

    Gastro-oesophageal reflux disease (GORD) is a common obesity-related co-morbidity that is assessed objectively by 24-h pH monitoring. Some concerns have been raised regarding the risk of de novo GORD or exacerbation of pre-existing GORD after laparoscopic sleeve gastrectomy. Here, 24-h pH monitoring was used to assess the influence of laparoscopic sleeve gastrectomy on postoperative GORD in obese patients with or without preoperative GORD. From July 2012 to September 2014, all patients scheduled for laparoscopic sleeve gastrectomy were invited to participate in a prospective follow-up. Patients who underwent preoperative 24-h pH monitoring were asked to repeat the examination 6 months after operation. GORD was defined as an oesophageal pH < 4 for at least 4·2 per cent of the total time recorded. Of 89 patients, 76 had preoperative pH monitoring for GORD evaluation and 50 had postoperative reassessment. Patients without (group 1, 29 patients) or with (group 2, 21 patients) preoperative GORD were similar regarding age, sex ratio and body mass index. In group 1, the median (i.q.r.) total time at pH < 4 was significantly higher after surgery than before: 5·6 (2·5-9·5) versus 1·6 (0·7-2·9) per cent (P < 0·001). Twenty of the 29 patients experienced de novo GORD as determined by 24-h pH monitoring (P < 0·001). In group 2, total time at pH < 4 after surgery was no different from the preoperative value: 5·9 (3·9-10·7) versus 7·7 (5·2-10·3) per cent (P = 0·296). Laparoscopic sleeve gastrectomy was associated with de novo GORD in over two-thirds of patients, but did not seem to exacerbate existing GORD. © 2016 BJS Society Ltd Published by John Wiley & Sons Ltd.

  19. V-stack piezoelectric actuator

    Science.gov (United States)

    Ardelean, Emil V.; Clark, Robert L.

    2001-07-01

    Aeroelastic control of wings by means of a distributed, trailing-edge control surface is of interest with regards to maneuvers, gust alleviation, and flutter suppression. The use of high energy density, piezoelectric materials as motors provides an appealing solution to this problem. A comparative analysis of the state of the art actuators is currently being conducted. A new piezoelectric actuator design is presented. This actuator meets the requirements for trailing edge flap actuation in both stroke and force. It is compact, simple, sturdy, and leverages stroke geometrically with minimum force penalties while displaying linearity over a wide range of stroke. The V-Stack Piezoelectric Actuator, consists of a base, a lever, two piezoelectric stacks, and a pre-tensioning element. The work is performed alternately by the two stacks, placed on both sides of the lever. Pre-tensioning can be readily applied using a torque wrench, obviating the need for elastic elements and this is for the benefit of the stiffness of the actuator. The characteristics of the actuator are easily modified by changing the base or the stacks. A prototype was constructed and tested experimentally to validate the theoretical model.

  20. Development of a system for monitoring and diagnosis using Fuzzy logic in control valves of laboratory test equipment of Experimental Center Aramar; Desenvolvimento de um sistema de monitoracao e diagnostico utilizando logica Fuzzy aplicado a valvulas de controle de processo do CEA - Centro Experimental Aramar

    Energy Technology Data Exchange (ETDEWEB)

    Porto Junior, Almir Carlos Soares

    2014-07-01

    The question of components reliability, specifically process control valves, has become an important issue to be investigated in nuclear power plants and other areas such as refinery or offshore oil rig, considering the safety and life extension of the plant. The development of non intrusive monitoring and diagnostic method allows the identification of defects in components of the plant during normal operation. The objective of this dissertation is to present an analysis and diagnosis of control valves of a steam plant part that simulates the secondary circuit of a pressurized water reactor. This installation is part of propulsion equipment testing laboratory of the Brazilian Navy, at Ipero-SP. The methodology for design is based on graphical analysis of two parameters, the valve air pressure actuator and the displacement of the valve plug. These data are extracted by a smart positioner, part of Delta V™ Automation System. An analysis is implemented in detecting anomalies by an approach using Expert Systems by the technique of fuzzy logic. Once the basic measures of control valves are taken, it is possible to detect symptoms of failure, leakage, friction, damage, etc. The monitoring and diagnostic system has been designed in MATLAB® version 2009{sup th} by the complement 'Fuzzy Logic Toolbox'. It is a noninvasive technique. Thus, it is possible to know what is happening with the chosen components, just analyzing the parameters of the valve. The software called ValveLink® (developed by Emerson) receives signals from hardware component (intelligent positioner) installed next to the control valve. These signals (electrical current) are transformed into information which are used input parameters: air pressure valve actuator and valve plug displacement. With the use of fuzzy logic, these parameters are interpreted. They suffer inferences by rules written by experts in valves. After these inferences, the information is processed and sent as output signals